Outer jacket Strain relief elements STB900H semi-tight buffered fiber

Fiber optic cables (SM / MM)

FiberConnect® Simplex indoor cable

I-V(ZN)H 1… UL OFNR Order no.

84 950 40 7 Q

Standardisation

IEC 60794-2

Description

Mechanical properties

Indoor cable with UL approbation type OFNR (Riser) for USA

outer diameter

2.9 mm

and Canada. Ideal for use in distribution systems as well as for

Cable weight

10.0 kg/km

connecting terminals.

Min. bending radius static

30 mm

Composition

Max. pull force

400 N

Max. crush resistance

150 N/dm

dynamic Cable core

Flame-retardant semi-tight buffered fiber

60 mm

(STB900H) Strain relief

Non-metallic (aramid)

Fire performance

Cable jacket

Halogen-free, flame-retardant material

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Colour of jacket

O blue

Smoke density

IEC 61034

Absence of halogen IEC 60754-1 Acidity of combus-

Thermal properties Transport/storage

– 25 °C to + 70 °C

tion gases

Installation

– 5 °C to + 50 °C

Fire load

Operating tempe-

– 10 °C to + 70 °C

rature

www.leoni-fiber-optics.com

IEC 60754-2 0.18 MJ/m

09 Approval (UL approbation type) Q

OFNR FT4 (NEC Article 770, UL 1651)

Q

c(UL)us


274

Fiber optic cables with UL approval

Fiber optic cables (SM / MM)

FiberConnect® Duplex indoor cable

Outer jacket Strain relief elements Tight buffered of semi-tight buffered fiber

I-V(ZN)H 2×1 UL OFNR Order no.

84 005 01 7 Q ZUL00

Standardisation

IEC 60794-2

Description

Thermal properties

Indoor cable approbation type OFNR (Riser) for USA and Canada.

Transport/storage

– 25 °C to + 70 °C

Ideal for use in distribution systems as well as for connecting

Installation

– 5 °C to + 50 °C

terminals.

Operating tempe-

– 10 °C to + 70 °C

rature Mechanical properties

Composition 2 flame-retardant semi-tight buffered

Outer dimensions

fibers

Cable weight

15.8 kg/km

Strain relief

Non-metallic (aramid)

Min. bending radius static

30 mm

Cable jacket

Halogen-free, flame-retardant material

Colour of jacket

O blue

Cable core

2.8 mm × 5.7 mm

dynamic

60 mm

Max. pull force

600 N

Max. crush resistance

600 N/dm

Fire performance

09

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Smoke density

IEC 61034

Absence of halogen IEC 60754-1 Acidity of combus-

IEC 60754-2

tion gases Fire load

0.36 MJ/m

Approval (UL approbation type) Q

OFNR FT4 (NEC Article 770, UL 1651)

Q

c(UL)us

www.leoni-fiber-optics.com


FiberConnect®

FiberTech ®

FiberSwitch ®

FiberSplit®

Fiber optic cables with UL approval

275

Outer jacket Strain relief elements STB900 semi-tight buffered fiber

Fiber optic cables (SM / MM)

FiberConnect® Duplex indoor cable

Subcable jacket Rip cord

I-V(ZN)H 1… UL OFNR Order no.

84 011 01 1 Q ZUL00

Standardisation

IEC 60794-2

Description

Mechanical properties

Indoor cable with UL approbation type OFNR (Riser). Ideal for

Outer dimensions

3.7 × 6.2 mm

use in distribution systems, for connecting terminals as well as

Cable weight

26.0 kg/km

for fixed installation.

Min. bending radius static

35 mm

Composition

Max. pull force

600 N

Max. crush resistance

600 N/dm

(over flat side) Cable core

Two single-fiber cables (STB900)

dynamic

65 mm

arranged in parallel beside each other with non-metallic strain relief elements

Fire performance

(aramid)

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

and a halogen-free, flame-retardant

Smoke density

IEC 61034

subcable jacket (Ø 2.5 mm)

Absence of halogen IEC 60754-1

Cable jacket

Halogen-free, flame-retardant material

Acidity of combus-

Colour of jacket

O orange for multimode

tion gases

O yellow for singlemode

Fire load

IEC 60754-2 0.65 MJ/m

09

Thermal properties

Approval (UL approbation type)

Transport/storage

– 25 °C to + 70 °C

Installation

– 5 °C to + 50 °C

Operating tempe-

– 10 °C to + 70 °C

rature

www.leoni-fiber-optics.com

OFNR (NEC Article 770, UL 1651)


276

Fiber optic cables with UL approval

Fiber optic cables (SM / MM)

FiberConnect® Duplex indoor cable

Outer jacket Strain relief elements STB900H semi-tight buffered fiber Subcable jacket Rip cord

I-V(ZN)HH 2×1 UL OFN Order no.

84 950 50 0 Q

Standardisation

IEC 60794-2

Description

Mechanical properties

Indoor cable with UL approbation type OFN (General Purpose)

Outer dimensions

3.0 × 5.0 mm

for USA and Canada. Ideal for use in distribution systems, for

Cable weight

18.5 kg/km

connecting terminals as well as for fixed installation.

Min. bending radius static

30 mm

Composition

Max. pull force

600 N

Max. crush resistance

1000 N/dm

dynamic Cable core

Two single-fiber cables STB900H

60 mm

arranged in parallel beside each other with non-metallic strain relief elements

Fire performance

(aramid) and a halogen-free, flame-retar-

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

dant subcable jacket (Ø 2.0 mm)

Smoke density

IEC 61034

Cable jacket

Halogen-free, flame-retardant material

Absence of halogen IEC 60754-1

Colour of jacket

O orange for multimode

Acidity of combus-

O yellow for singlemode

tion gases Fire load

IEC 60754-2 0.62 MJ/m

Thermal properties

09

Transport/storage

– 25 °C to + 70 °C

Approval (UL approbation type)

Installation

– 5 °C to + 50 °C

Q

OFN FT1 75 °C (NEC Article 770, UL 1651)

Operating tempe-

– 10 °C to + 70 °C

Q

c(UL)us

rature

www.leoni-fiber-optics.com


FiberConnect®

FiberTech ®

FiberSwitch ®

FiberSplit®

Fiber optic cables with UL approval

277

Outer jacket Fleece Dummy element

Fiber optic cables (SM / MM)

FiberConnect® Duplex outdoor cable

Tight buffered fiber Strain relief elements

AT-V(ZN)YY 2… UL OFNR Order no.

84 950 63 2 Q

Standardisation

IEC 60794-2

Description

Mechanical properties

Extremely temperature-stable and UV-hard outdoor cable,

outer diameter

7.0 mm

tested according to UL OFNR flame test. Ideal for use in harsh

Weight

44.0 kg/km

environments such as mobile base stations.

Min. bending radius static

70 mm

Composition

Max. pull force

600 N

Max. crush resistance

800 N/dm

(over flat side) Cable core

Stranding consisting of two PVC single

dynamic

105 mm

cables with tight buffered fibers (TB900L) with non-metallic strain relief elements

Fire performance

(aramid) (Ø 2.4 mm)

Flame retardancy

Cable jacket

Flame-retardant polyvinyl chloride (PVC)

Colour of jacket

O black

Thermal properties Transport/storage

– 55 °C to + 85 °C

Installation

– 20 °C to + 60 °C

Operating tempe-

– 40 °C to + 85 °C

rature

www.leoni-fiber-optics.com

IEC 60332-1-2

Approval (UL approbation type) Q

OFNR FT4 (NEC Article 770, UL 1651)

Q

c(UL)us

09


278

Fiber optic cables with UL approval

Fiber optic cables (SM / MM)

FiberConnect® Duplex outdoor cable

Outer jacket Dummy element Tight buffered fiber Rip cord Strain relief elements

AT-V(ZN)YY 2… UL AWM Style Order no.

84 950 50 4 Q

Standardisation

IEC 60794-2

Description

Thermal properties

Extremely temperature-stable and UV-hard outdoor cable,

Transport/storage

– 55 °C to + 85 °C

tested acc. to UL VW-1 flame test. Ideal for use in harsh environ-

Installation

– 20 °C to + 60 °C

ments such as mobile base stations.

Operating tempe-

– 40 °C to + 85 °C

rature Mechanical properties

Composition Cable core

Stranding consisting of two PVC single ele-

outer diameter

ments with tight buffered fibers (TB900A)

7.0 mm

Weight

44.0 kg/km

with non-metallic strain relief elements

Min. bending radius static

70 mm 105 mm

(aramid) (Ø 2.4 mm)

(over flat side)

Cable jacket

Flame-retardant polyvinyl chloride (PVC)

Max. pull force

800 N

Colour of jacket

O black

Max. crush resistance

800 N/dm

dynamic

Fire performance Flame retardancy

IEC 60332-1-2 and VW-1 flame test

09 Approval (UL approbation type) UL-AWM Style 5432

www.leoni-fiber-optics.com


FiberConnect®

FiberTech ®

FiberSwitch ®

FiberSplit®

Fiber optic cables with UL approval

279

PVC Outer jacket Fleece wrapping Rip cord GFR strength member

Fiber optic cables (SM / MM)

FiberConnect® Splittable outdoor cable

PVC subcable jacket Buffered optical fiber Strain relief elements

AT-V(ZN)YY n… UL OFNR Order no.

84 217 Q Q Q Q

Standardisation

IEC 60794-2

Description

Mechanical properties

Extremely temperature-stable and UV resistant outdoor cable,

Min. bending radius static dynamic

tested acc. to UL OFNR flame test. Ideal for use in harsh environments such as mobile base stations and wind turbines.

Max. crush resistance

10 × outer diameter 15 × outer diameter 1000 N/dm

For direct connector assembly. Fire performance Composition

Q

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

GFR strength member in the core, over

Q

OFNR FT4 (NEC Article 770, UL 1651)

that single elements stranded in one layer.

Q

c(UL)us

Flame retardancy

Cable core

Single element (TB900L) made from PVC (Ø 2.2 mm). Orange colour for multimode

Approval (UL approbation type)

and yellow for singlemode and non-me-

Q

OFNR FT4 (NEC Article 770, UL 1651)

tallic strain relief elements (aramid).

Q

c(UL)us

Cable jacket

Flame-retardant polyvinyl chloride (PVC)

Colour of jacket

O black

Chemical properties

Thermal properties Transport/storage

–40 °C to + 85 °C

Installation

– 5 °C to + 50 °C

Operating tempe-

– 40 °C to + 85 °C

2 4 6 8 10 12

Outer Ø

Wall thickness

Weight

max. Pull force

mm

mm

kg/km

N

7.8 7.8 9.2 10.5 11.9 13.3

1.2 1.2 1.2 1.2 1.2 1.2

60 60 85 110 140 180

www.leoni-fiber-optics.com

Good resistance to oil, petrol, acids and alkaline solutions

Q

UV resistance of outer jacket acc. to DIN EN ISO 4892-2, test method A, UV applications up to 500 hours

rature

Max. number of fibers

Q

800 800 1200 1200 1200 1200

09


280

Fiber optic cables with UL approval

Fiber optic cables (SM / MM)

FiberConnect® Splittable outdoor cable

PVC outer jacket Strain relief elements Fleece wrapping Rip cord GFR strengh member PVC subcable jacket Buffered optical fiber Strain relief elements

AT-V(ZN)Y(ZN)Y n … UL OFNR Order no.

84 218 Q Q Q Q

Standardisation

IEC 60794-2

Description

Mechanical properties

Extremely temperature-stable and UV-resistant outdoor cable,

Min. bending radius static dynamic

tested acc. to UL OFNR flame test. Ideal for use in harsh environments such as mobile base stations and wind turbines.

Max. crush resistance

10 × outer diameter 15 × outer diameter 2000 N/dm

For direct connector assembly. Fire performance Composition

Q

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

GFR strength member in the core, over

Q

OFNR FT4 (NEC Article 770, UL 1651)

that single elements stranded in one layer.

Q

c(UL)us

Flame retardancy

Cable core

Single element (TB900L) made from PVC

09

(Ø 2.2 mm), orange colour for multimode

Approval (UL approbation type)

and yellow for singlemode and non-

Q

Type OFNR FT4 (NEC Article 770, UL 1651)

metallic strain relief elements (aramid)

Q

c(UL)us

Cable jacket

Flame-retardant polyvinyl chloride (PVC)

Colour of jacket

O black

Chemical properties

Thermal properties Transport/storage

–40 °C to + 85 °C

Installation

– 5 °C to + 50 °C

Operating tempe-

– 40 °C to + 85 °C

Q

Good resistance to oil, petrol, acids and alkaline solutions

Q

UV-hardness of outer jacket acc. to DIN EN ISO 4892-2, test method A, UV applications up to 500 hours

rature

Max. number of fibers

2 4 6 8 10 12

Outer--Ø

Wall thickness

Weight

Max. pull force

mm

mm

kg/km

N

8.4 8.4 10.1 11.4 12.8 14.2

1.2 1.2 1.2 1.2 1.2 1.2

70 70 95 120 150 190

2000 2000 3000 3000 3000 3000 www.leoni-fiber-optics.com


FiberConnect®

FiberTech ®

FiberSwitch ®

FiberSplit®

Fiber optic cables with UL approval

281

FiberConnect® Splittable outdoor cable

FRNC outer jacket Fleece wrapping Rip cord GFR strength member

Fiber optic cables (SM / MM)

Breakout cable for wind turbines

FRNC subcable jacket Buffered optical fiber Strain relief elements

AT-V(ZN)HH n… TB900L Order no.

84 222 Q Q Q Q

Standardisation

IEC 60794-2

Description

Thermal properties

Developed especially for data transmission between control

Transport/storage

–40 °C to + 70 °C

cabinets in wind power plants.

Installation

– 25 °C to + 50 °C

For flexible use in the revolving cable harness

Operating tempe-

– 40 °C to + 70 °C

in wind power plants

rature

Q

UL OFNR flame test

Mechanical properties

Q

Ideal for use in wind turbines

Min. bending radius static

Q

For direct connector assembly

Q

dynamic Torsion

Composition Cable core

10 × outer diameter 15 × outer diameter

IEC60794-1-2 E7 2000 cycles, rotation ±144°/m

GRF strength member in the core, over

Max. crush resistance

1000 N/dm

that single elements stranded in one layer.

Cable jacket

Single element (TB900L) from flame-

Fire performance

retardant FRNC (Ø 2,2 mm), orange colour

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-24 Cat. C

for multimode and yellow for singlemode

Smoke density

IEC 61034

and non-metallic strain relief elements

Absence of halogen IEC 60754-1

(aramid)

Acidity of combus-

Halogen-free, flame-retardant and

tion gases

IEC 60754-2

oil-resistant material (FRNC) Colour of jacket

O black

Approval (UL approbation type) Q

UL 1651 OFNR (UL 1666) (NEC Article 770)

Chemical properties Q

Number of fibers

2 4 6 8 10 12

Outer Ø

Weight

Pull force

mm

kg/km

N

7.8 7.8 9.2 10.5 11.9 13.3

63 63 90 110 140 189

www.leoni-fiber-optics.com

800 800 1200 1200 1200 1200

Very good resistance to oil, grease, acids and alkaline solutions

Q

Resistance of outer jackets to media and oil acc. to VG 95218-30 type B

09


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.