    ©  The  Skylar  Project  2011.    All  Rights  Reserved     NOTICE OF CONFIDENTIALITY This document including any information transmitted with it is intended only for the use of the addressees and is confidential. If you are not an intended recipient or responsible for delivering the message to an intended recipient, any review, disclosure, conversion to hard copy, dissemination, reproduction or other use of any part of this communication is strictly prohibited, as is the taking or omitting of any action in reliance upon this document. If you receive this document in error or without authorization please notify us immediately or otherwise and permanently delete the entire document from any computer, disk drive, or other storage medium.

            1  

 


THE  SKYLAR  PROJECT:    FÁBRICA  NETWORK   300  NEW  TORONTO  STREET,  SUITE  3600,  M8V  2E8   TORONTO,    ONTARIO,  CANADA   TEL:  +1  647  977  9176  or  TEL:    +1  888  788  8034,    FAX:  +1  888  588  1945   EMAIL:    INFO@THESKYLARPROJECT.COM  

 

  Skylar  Wall  Panel  Product  Performance   Test

Test Method

Criteria

Results

Air Leakage

ASTM E 283

No Criteria

Water Penetration ICC ES (AC 212)

ASTM E 331

Drainage Efficiency ICC ES (AC 235) Accelerated Weathering

ASTM E 2273

No water penetration beyond the inner-most plane for the wall after 15 minutes at 137 Pa (2.86 Psf for drainage systems and after 2 hours at 300 Pa (6.24 Psf) for barrier systems Minimum Drainage Efficiency of 90% No deleterious effects after 2000 hours

0.6l/min/m2 (0.002 cfm/ft2) Passed

Freeze Thaw (formerly EIMA 101.01) Impact Resistance (formerly EIMA Std. 101.86) Transverse Wind Load

Fire Resistance Intermediate Multistory Fire Test

Full Scale Multi-Story (corner test)

ASTM G 155 Cycle 1 ASTM G 154 Cycle 1 (QUV) ASTM E 2485

Passed No deleterious

No deleterious effects after 60 cycles

Passed – No deleterious effects after 90 cycles

ASTM E 2486

No fracture of reinforcing mesh

Meets all requirements in each mesh category

ASTM E 330

Withstand positive and negative loads as specified by the building code

ASTM E 119 NFPA 268 NFPA 285 (UBC 26-9)

No effect of a rated wall assembly 1. Resist flame propagation over the exterior surface 2. Resist vertical spread of flame within combustible core/component of panel from one story to the next 3. Resist vertical spread of flame over the interior surface from one story to the next 4. Resist lateral spread of flame from the compartment of the fire of origin to the adjacent spaces Resist flame propagation over the exterior surface

Minumum 4.3 kPa (90 Psf)* 16 inch o.c. framing, .5 in. sheathing screw attached at 203 mm (8 inch) o.c. Passed 1 hour

ANSI FM 4880

Passed

Passed; No height restrictions for Outsulation of Outsulation Plus MD

  Additional  product  performance  information  is  available  on  request.    Product   performance  may  vary  according  to  specific  implementation,  as  building  code  and   engineering  specifications  may  call  for  additional  criteria  to  be  considered.                 2  

 