AIR SAMPLING 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM 2 4 PUMPS AIR SAMPLING AIR MONITORING AIR ODOUR CONTROL AIR FILTRATION & TREATMENT 14 CALIBRATORS & ROTAMETERS 16 IAQ, BIOAEROSOL & MICROBIOLOGICAL SAMPLERS 19 IMPACTORS & CYCLONES 21 CALIBRATION ACCESSORIES & SURFACE SAMPLERS 22 CASSETTES 27 TUBES & TUBE HOLDERS 28 PERSONAL & AREA PUMP ACCESSORIES 30 GAS SAMPLING BAGS 32 PASSIVE MONITORING BADGES 34 COLORIMETRIC TUBES & PUMPS 38 SINGLE GAS DETECTORS 48 MULTI-GAS DETECTORS 60 VOC DETECTORS 66 BENZENE DETECTORS 70 NEUTRALIZER 70 HVAC FILTERS 70 MEDIA 71 HVAC FILTERS 72 MEDIA 75 AIR TREATMENT SYSTEMS See inside back cover for ordering information.

WHY CHOOSE ERE?

AIR SAMPLING AIR SAMPLING 3

Available To Rent

Gilian® BDX-II Abatement Personal Air Sampling Pump

The Gilian® BDX-II is designed specifically for asbestos and lead abatement applications when constant flow is not required. The built-in rotameter displays flow rates over the entire flow range of 0.5 - 3.0 LPM and an electronic flow control adjustment enables parts to last longer so maintenance is minimized. Sealed flow adjustment and on/off switch protects the Gilian® BDX-II from moisture, dust and fibers.

Features

• Flow rate: 500 - 3,000 cc/min (total)

• Built-in rotameter

• Will operate 10 hours at 2.0 LPM with inlet pressure of 20"

• Rechargeable NiMH battery pack

• Certifications: Not Intrinsic Safe

Starter Kit Includes

• Gilian® BDX-II pump

• 36" tubing

• Clip assembly

• Reversible screwdriver

• Single unit charger

• User manual

5-Pump Kit Includes

• (5) Gilian® BDX-II pumps

• (5) Pieces of 36" tubing

• (5) Clip assemblies

• (5) Reversible screwdrivers

• (5) Single unit chargers or (1) Gilian® 5-station charger or (1) Zefon® 5-station charger

• (5) User manuals

• Heavy-duty foam lined carrying case

Inf

Z neDifferences Between Basic, Clock & Programmable Models

• The Basic model is straight-forward and easy to use.

• Clock models provide an elapsed-time clock display.

• Programmable models enable a timer which can start or stop the pump at preset time intervals or program a delayed start.

Gilian® LFS-113 Compact, Pocket-Sized, Personal Low Flow Air Sampling Pump

The Gilian® LFS-113 is designed for flow rates between 1 - 350 cc/min, perfect for very low flow application sampling with sorbent tubes. Offers two user selectable sampling modes; the constant flow control mode holds the flow within ±5% of the set flow while the constant pressure control mode (multi-flow) allows multiple samples to be taken simultaneously through the use of a multi-flow manifold. No other pocket-sized pump matches the wide flow range and high back-pressure capability of the Gilian® LFS-113.

Features

• Flow rate: 1 - 350 cc/min (total)

• Dual mode automatic constant flow or constant pressure control

• Flow fault indicator light

• Battery check LED

• Rechargeable NiMH battery pack

• Certifications: ATEX, CSA, C-US & UL

• 36" tubing

• Air boss kit

• Single tube holder

• Reversible screwdriver

• Single unit charger

• User manual

AIR SAMPLING 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM 4
Approvals - Intrinsic
Part Number Description Model Flow Rate Power Source GIL-910-0301-01 Gilian® LFS-113 D Starter Kit Basic 1 - 350 cc/min 120V GIL-910-0302-01 Gilian® LFS-113 D 5-Pump Kit Basic 1 - 350 cc/min 120V GIL-800400 18" x 13" x 7" Carrying Case - -Starter Kit Includes
Safe
Gilian® LFS-113
pump
5-Pump Kit Includes
(5) Gilian® LFS-113 pumps
(5) Pieces of 36" tubing
(5) Air boss kits
(5) Single tube holders
(5) Reversible
screwdrivers
5-Unit charger
(5) User
manuals
Part Number Description Flow Rate (Total) Power Source GIL-801863-171-1201 Gilian® BDX-II Starter Kit 500 - 3,000 cc/min 120V GIL-801863-171-KIT Gilian® BDX-II 5-Pump Kit With 5-Single Unit Chargers 500 - 3,000 cc/min 120V GIL-801863-171-KIT5 Gilian® BDX-II 5-Pump Kit With Gilian® 5-Station Charger 500 - 3,000 cc/min 120V GIL-801863-171Z-KIT5 Gilian® BDX-II 5-Pump Kit With Zefon® 5-Station Charger 500 - 3,000 cc/min 120V GIL-800511 17.5" x 13" x 7" Carrying Case -
-

The Gilian® GilAir-3 and Gilian® GilAir-5 pumps are suitable not only for conventional pull-through sampling media but also for bag sampling and other pressure applications. These 3 and 5 LPM air sampling pumps have automatic constant flow compensation, assuring sampling is maintained within ±5% of the initial set point, even with varying back-pressures from flow restrictions or buildup of material on the filter.

Features

• Flow rate:

Gilian® GilAir-3: 1- 3,000 cc/min (total)

Gilian® GilAir-5: 1- 5,000 cc/min (total)

• Optional low flow modules

• Flow fault & test indicators

• External filter housing

• Rechargeable NiMH battery pack

• Certifications: UL - Intrinsic Safe

GIL-800884-171-1205

GIL-800511 17.5" x 13" x 7" Carrying Case

Starter Kit Includes

• Gilian® GilAir-3 or Gilian® GilAir-5 pump

• 36" tubing

• Air boss kit

• Filter cassette holder

• Reversible screwdriver

• Single unit charger

• User manual

5-Pump Kit Includes

• (5) Gilian® GilAir-3 or Gilian® GilAir-5 pumps

• (5) Pieces of 36" tubing

• (5) Air boss kit

• (5) Filter cassette holder

• (5) Reversible screwdriver

• 5-Unit charger

• (5) User manual

• Carrying case

AIR SAMPLING AIR SAMPLING 5
Part Number Description Model Flow Rate (Total) Power Source GIL-800485-171-1201 Gilian® GilAir-3 R Starter Kit Basic 1 - 3,000 cc/min 120V GIL-800485-171-1205 Gilian® GilAir-3 R 5-Pump Kit With 5-Unit Charger Basic 1 - 3,000 cc/min 120V GIL-800508-171-1201 Gilian® GilAir-3 RC Starter Kit Clock 1 - 3,000 cc/min 120V GIL-800508-171-1205 Gilian® GilAir-3 RC 5-Pump Kit With 5-Unit Charger Clock 1 - 3,000 cc/min 120V GIL-800510-171-1201 Gilian® GilAir-3 RP Starter Kit Programmable 1 - 3,000 cc/min 120V GIL- 800510-171-1205 Gilian® GilAir-3 RP 5-Pump Kit With 5-Unit Charger Programmable 1 - 3,000 cc/min 120V GIL-800883-171-1201 Gilian® GilAir-5 R Starter Kit Basic 1 - 5,000 cc/min 120V GIL-800883-171-1205 Gilian® GilAir-5 R 5-Pump Kit With 5-Unit Charger Basic 1 - 5,000 cc/min 120V
Gilian® GilAir-5 RC Starter Kit Clock 1 - 5,000 cc/min 120V GIL- 800885-171-1205 Gilian® GilAir-5 RC 5-Pump Kit With 5-Unit Charger Clock 1 - 5,000 cc/min 120V
Gilian® GilAir-5 RP Starter Kit Programmable 1 -
GIL-800885-171-1201
GIL-800884-171-1201
5,000 cc/min 120V
Programmable
Gilian® GilAir-5 RP 5-Pump Kit With 5-Unit Charger
1 - 5,000 cc/min 120V
- - -
Need Help Deciding On A Pump? 1. What flow rate do you require? 2. What sampling method are you using?
Bags (need an exhaust port)
Tubes
Cassettes
What gas (or gases) are you sampling for? Answer the following questions to help narrow it down.
Will you need a calibrator?
Extra bells and whistles?
3.
4.
5.
Data logging
Bluetooth
Programmable
• Etc. Gilian® GilAir-3 & Gilian® GilAir-5 Personal Air Sampling Pumps

Gilian® GilAir® Plus

Personal Air Sampling Pump

The Gilian® GilAir® Plus is the world’s most capable air sampling pump now with 3 new technologies such as Motion Detection, BluetoothTM Connectivity and the CONNECT Mobile App!

Three models to choose from; the basic model, the datalogging pump (DL) model and the standard temperature and pressure (STP) model.

Features

• Flow rate: 1 - 5,100 cc/min (total)

• Flow modes: constant flow or high and low flow constant pressure

• QuadModeSM air sampling technology

• Selectable automatic fault recovery

• SmartCalSM automatic calibration

• High back pressure capability

• Temperature & pressure compensation

• Rechargeable NiMH battery pack

• Certifications: EN 1232 Compliant, ISO 13137:2013 Compliant, Intrinsic Safe, US/Canada NRTL (FM), ATEX, CE Applicable Directives

Starter Kit Includes

• Gilian® GilAir® Plus pump

• Tubing

• Filter cassette holder

• Charcoal tube holder

• 2 mm hex key

• Charging dock with power adapter

• User manual

• Single unit carrying case

• Data logging and STP models also include a communication enabled charging dock & Gilian® pump management software

• (5)

• (5) Filter cassette holders

• (5)

• (5) 2 mm hex

• 5-Unit power station

• (5)

• 5-Unit

• Data logging and STP models also include a communication enabled charging dock & Gilian® pump management software

Inf Z ne

Differences Between Basic, Data Logging, & STP Models

• The basic model is straight forward and easy to use.

• The data logging model provides additional advanced program functions and allows data logging and transferring of data to a PC. Also available with BluetoothTM option.

• The STP model refers to standard temperature and pressure. These models correct the display flow rate and air volume to standard conditions of temperature and pressure. Also available with BluetoothTM option.

AIR SAMPLING 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM 6
Part Number Description Model Flow Rate (Total) Power Source GIL-910-0901-US-R Gilian® GilAir® Plus Starter Kit Basic 1 - 5,100 cc/min 120V GIL-910-0904-US-R Gilian® GilAir® Plus 5-Pump Kit With 5-Unit Power Station Basic 1 - 5,100 cc/min 120V GIL-910-0902-US-R Gilian® GilAir® Plus Starter Kit Data Logging 1 - 5,100 cc/min 120V GIL-910-0905-US-R Gilian® GilAir® Plus 5-Pump Kit With 5-Unit Power Station Data Logging 1 - 5,100 cc/min 120V GIL-910-0910-US-R Gilian® GilAir® Plus Starter Kit BT Data Logging 1 - 5,100 cc/min 120V GIL-910-0912-US-R Gilian® GilAir® Plus 5-Pump Kit With 5-Unit Power Station BT Data Logging 1 - 5,100 cc/min 120V GIL-910-0903-US-R Gilian® GilAir® Plus Starter Kit STP 1 - 5,100 cc/min 120V GIL-910-0906-US-R Gilian® GilAir® Plus 5-Pump Kit With 5-Unit Power Station STP 1 - 5,100 cc/min 120V GIL-910-0911-US-R Gilian® GilAir® Plus Starter Kit BT STP 1 - 5,100 cc/min 120V GIL-910-0913-US-R Gilian® GilAir® Plus 5-Pump Kit With 5-Unit Power Station BT STP 1 - 5,100 cc/min 120V *3-Pump kits also available
5-Pump Kit Includes
Gilian® GilAir® Plus pumps
tubing
(5) Pieces of
Charcoal tube holders
keys
manuals
User
carrying case
Available To Rent

High Efficiency Air Sampling Pumps

Gilian® Power Series Personal Air Sampling Pumps

The Gilian® Power Series is the industry leader in back pressure performance, reliability and ease-of-use. They also provide automatic constant flow controls and the Gilian® 5000 has an optional adapter module, which can handle lower flows under constant pressure control, such as required for multi-flow sorbent sampling.

Features

• Flow rate:

Gilian® 800i: 200 - 800 cc/min (total)

Gilian® 5000: 20 - 5,000 cc/min (total)

Gilian® 10i: 4,000 - 10,000 cc/min (total)

Gilian® 12: 4,000 - 12,000 cc/min (total)

• Highest back-pressure capability

• Programmable

• Live flow display

• Rechargeable NiMH battery pack

• Certifications:

Gilian® 800i, Gilian® 5000 & Gilian® 10i: Intrinsic Safe, US/Canada NRTL (FM), ATEX & CE Applicable

Gilian® 12: Not Instrinsic Safe

• Gilian® 800i pump

• 1/4" x 36" tubing

• Single unit charger

• User manual

5-Pump Kit Includes

Includes • (5) Gilian® 800i pumps

• (5) Pieces of 1/4" x 36" tubing

• 5-Unit power station

• (5) User manuals

• Carrying case

• Gilian® 5000 pump

• Filter cassette holder

• Single unit charger

• User manual

• Gilian® 10i pump

• 3/8" x 36" tubing

• Single unit charger

• User manual

• Gilian® 12 pump

• 3/8" x 36" tubing

• Single unit charger

• User manual

• (5) Gilian® 5000 pumps

• (5) Filter cassette holders

• 5-Unit power station

• (5) User manuals

• Carrying case

• (5) Gilian® 10i pumps

• (5) Pieces of 3/8" x 36" tubing

• 5-Unit power station

• (5) User manuals

• Carrying case

• (5) Gilian® 12 pumps

• (5) Pieces of 3/8" x 36" tubing

• 5-Unit power station

• (5) User manuals

• Carrying case

AIR SAMPLING AIR SAMPLING 7
Model Gilian 800i Gilian® 5000 Gilian® 10i Gilian® 12 Includes
Starter Kit Includes
Model Gilian® 800i Gilian® 5000 Gilian® 10i Gilian® 12
Part Number Description Flow Rate (Total) Power Source GIL-910-1301-US Gilian® 800i Starter Kit With US Cord 200 - 800 cc/min 120V/230V GIL-910-1305-US Gilian® 800i 5-Pump Kit With US Cord 200 - 800 cc/min 120V/230V GIL-910-0802-01 Gilian® 5000 Starter Kit With US Cord 20 - 5,000 cc/min 120V/240V GIL- 910-0801-01 Gilian® 5000 5-Pump Kit With US Cord 20 - 5,000 cc/min 120V/240V GIL-910-1501-US Gilian® 10i Starter Kit With US Cord 4,000 - 10,000 cc/min 120V/240V GIL-910-1505-US Gilian® 10i 5-Pump Kit With US Cord 4,000 - 10,000 cc/min 120V/240V GIL-910-1601-US Gilian® 12 Starter Kit With US Cord 4,000 - 12,000 cc/min 120V/240V GIL-910-1605-US Gilian® 12 5-Pump Kit With US Cord 4,000 - 12,000 cc/min 120V/240V

Gilian® AirCon-2 Portable High Volume Constant Flow

Area Air Sampling Pump

The Gilian® AirCon-2 sampler is a high volume unit with an extended flow range, designed for collecting particulate in a given plant area. It is ideal for asbestos background and clearance sampling following NIOSH, OSHA or EPA methodology and for ambient dust monitoring.

Features

• Flow rate: 2 - 30 LPM (total)

• Fully programmable

• Touchpad & LCD display

• Instant fault function

• Instant pressure check

• Operates off either AC or battery power

• Certifications: Not Instrisic Safe

Includes

• Gilian® AirCon-2 pump

• Hose

• Sampling mast

• Support tip

GIL-801001 Lead Acid Gel 4-Hour Battery Pack

GIL-801171-1

22''

-

Zefon® Escort® LC Personal Air Sampling Pump

The Zefon® Escort® LC air sampling pump can be used with a variety of personal and area sampling devices to collect such airborne contaminants as asbestos fibers, toxic gases, vapors, particulates, fumes and mists. It can also be used to sample silica dust, coal dust and organic vapors.

Features

• Flow range: 0.5 - 3 LPM (total)

• Inlet filter traps particulate matter

• Separate LEDs indicate pump operation and low battery

• Stainless steel-filled plastic case provides EMI/RFI protection

• Rechargeable NiMH battery pack

• Certifications: UL Approved as Intrinsically Safe for use in Hazardous Locations, Class I, Groups A, B, C, D; Class II, Groups E, F and G; Class III, Division I Locations

Includes

• Escort® LC pump

• Sampling line

• 120V charger

• User manual

5-Pump Kit Includes

• (5) Escort® LC pumps

• (5) Sampling lines

• 5-Unit charger

• User manual

• Carrying case

Please

refer to page 28 for more information.

36'' Sampling Line with Tube Clip ZE-456226 3/8'' O.D. x 1/4'' I.D. Clearflex 60 Non-Phtalate PVC Tubing, 100 ft CY-8860-4335 Universal Cassette or Cyclone Holder ZE-ZA0061 Sorbent Tube Holder APB-109030 Metal Luer Adapter ZE-459743 37mm Cassette Tubing Adapters ZE-ZA0005

AIR SAMPLING 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM 8
Part Number Description Flow Rate (Total) Power Source ZE-711400 Zefon® Escort® LC With 120V Charger 0.5 - 3 LPM 120V ZE-P5-ESLC-5-1-0-0 Zefon® Escort® LC 5-Pump Kit With 5-Unit Charger 0.5 - 3 LPM 120/240V ZE-811741 Protective Leather Holster Case - -
Part Number Description Flow Rate (Total) Power Source GIL-801012-100 Gilian® Aircon-2 DC Programmable Area Air Sampling Pump
2 - 30 LPM 120V
Power
Only
GIL-801000-2
Module 120V/230V/DC With 120V Cord - -
Requires Power Module (GIL-80100-2) To Charge (Note: May Stack (2) For 8-Hour Operation) -
x 16'' x 8'' Wheeled Carrying Case For AirCon-2 - -
• User manual
Personal Pump Accessories

Zefon® Escort ELF® Personal Air Sampling Pump

The Zefon® Escort ELF® air sampling pump features a state of the art electronic laminar flow sensor to provide a constant flow control with ± 2.5% regulation of flow rate from 1 - 3 LPM with automatic compensation for changes in battery voltage, temperature, altitude, and sample load. An internal secondary standard calibrates the pump continuously and needs to be checked against a primary standard only once per month (or every 200 hours for coal mine dust sampling).

Features

• Flow rate: 0.5 - 3 LPM (total)

• Patented electronic laminar flow control

• Inlet filter traps moisture and particular matter

• Stainless steel-filled plastic case provides EMI/RFI protection

• Rated IP65 for resistance to water and dust ingress

• Flow fault indicator shows any sample inlet blockage

• Run/Hold feature allows "time out" during sampling process

• Elapsed time readout and low-battery warning

• Low flow and dual tube sampling available with Zefon® Gemini

Sampler

• Rechargeable NiMH battery pack

• Certifications: NIOSH, MSHA, UL, ATEX specific models only

Includes

• Zefon® Escort ELF® pump

• Sampling line

• 120V charger

• User manual

5-Pump Kit Includes

• (5) Zefon® Escort ELF® pumps

• (5) Sampling lines

• 5-Unit charger

• User manual

• Carrying case

*

Buck Libra™ L-4 Abatement Personal Air Sampling Pump

The Buck Libra™ L-4 is designed for sampling of asbestos, lead, and other airborne contaminates. This pump is used to draw air contaminants in through a sampling media such as 25 and 37 mm filter cassettes which is used to gauge personnel exposure to gases, vapors, particulates, aerosols, etc. It is capable of delivering up to 4.0 LPM for periods exceeding 8 hours. Low flows from 5 - 800 cc/min can be obtained using the optional Adjustable Universal Low Flow Holder.

Features

• Flow rate: 0.8 - 4.0 LPM (total) 5 - 800 cc/min with optional Adjustable Universal Low Flow Holder (APB-109030)

• High impact steel fiber filled Lexan case, antistatic and RFI shielded

• "Auto-Restart" within one minute of a flow fault

• High backpressure capable for 25 mm 0.45 μm asbestos filters

• Built-in washable stainless steel 100 μm filter for economy of use

• Stainless steel belt clip with built-in tripod connector

• Rechargeable NiMH battery pack

• Certifications: CE EMC Directive (EMCD) 89/336/EEC

Sarter Kit Includes

• Buck Libra™ L-4 pump

• 3 ft of vinyl hose

• Luer hose adapter

• Shirt/hose clip

• Single pack NiMH battery

• 120V charger

• User manual

5-Pump Kit Includes

• (5) Buck Libra™ L-4 pumps

• (5) Pieces of 3 ft of vinyl hose

• (5) Luer hose adapters

• (5) Shirt/hose clips

• (5) Single pack NiMH batteries

• QuickFive™ charger 100-240V

• (2) User manuals

• Pelican carrying case model 1500

*230V also available

AIR SAMPLING AIR SAMPLING 9
Twin-Port
Part Number Description Flow Rate (Total) Power Source ZE-805560 Zefon® Escort ELF® With 120V Charger & Sampling Line 0.5 - 3 LPM 120V ZE-805563 Zefon® Escort ELF® With 5-Unit Charger & Sampling Line 0.5 - 3 LPM 120/240V ZE-805559 Zefon® Escort ELF® With 120V Charger & Gemini® Twin Port Sampler 0.5 - 3 LPM 120V ZE-711396 Zefon® Escort ELF® With 5-Unit Charger & Gemini® Twin Port Sampler 0.5 - 3 LPM 120/240V ZE-811741 Protective Leather Holster Case - -
240V also available
Part Number Description Flow Rate (Total) Power Source APB-926000 Buck Libra™ L-4 Starter Kit 0.8 - 4.0 LPM 120V APB-942600 Buck Libra™ L-4 5-Pump Kit 0.8 - 4.0 LPM 120V APB-109030
Flow Holder - -
Adjustable Universal Low

Buck Libra Plus™ Series Personal Air Sampling Pump

The Buck Libra Plus™ is designed for sampling of asbestos, lead, and other airborne contaminates. These pumps display flow rate, elapsed time and accumulated volume of the sample.

The Buck Libra Plus™ model LP-1 and LP-5 is used to draw air contaminants in through a sampling media such as 25 mm and 37 mm filter cassettes whereas the Buck Libra Plus™ model LP-7, LP-12 and LP-20 can also use 47 mm filter cassettes; which is used to gauge personnel exposure to gases, vapors, particulates, aerosols, etc.

Features

• Flow rate:

Buck Libra Plus™ LP-1: 100 - 600 cc/min (total)

5 - 99 cc/min with optional Adjustable Universal Low Flow Holder (APB-109033)

Buck Libra Plus™ LP-5: 0.8 - 5.0 LPM (total)

5 - 799 cc/min with optional Adjustable Universal Low Flow Holder (APB-109030)

Buck Libra Plus™ LP-7: 3.0 - 7.0 LPM (total)

Buck Libra Plus™ LP-12: 3.0 - 12.0 LPM (total)

50 - 800 cc/min with optional Adjustable Universal Low Flow Holder (APB-109030)

Buck Libra Plus™ LP-20: 5.0 - 20.0 LPM (total)

• Displays: elapsed time, accumulated volume and flow rate

• "Auto-Restart" within one minute of a flow fault

• High backpressure capable for 25 mm 0.45 μm asbestos filters

• Built-in washable stainless steel 100 μm filter for economy of use

• Stainless steel belt clip with built-in tripod connector

• Rechargeable NiMH battery pack

• Certifications: CE EMC Directive (EMCD) 89/336/EEC

hose adapter

• Shirt/hose clip

• Non-adjustable tube holder

• Single pack NiMH battery

• Standard 120V battery charger

• User manual

• Buck Libra Plus™ LP-12 pump

• 3 ft of vinyl hose

• Luer hose adapter

• Shirt/hose clip

• Non-adjustable tube holder

• Triple pack NiMH battery

• Standard 120V battery charger

• User manual

• Buck Libra Plus™ LP-20 pump

• 3 ft of vinyl hose

• Luer hose adapter

• Shirt/hose clip

• Non-adjustable tube holder

• Triple pack NiMH battery

• Standard 120V battery charger

• User manual

Includes

• (5) Buck Libra Plus™ LP-1, LP-5 or LP-7 pumps

• (5) Pieces of 3 ft of vinyl hose

• (5) Luer hose adapters

• (5) Shirt/hose clips

• Non-adjustable tube holder

• (5) Single pack NiMH batteries

• Quick(5)™ charger 100-240V

• (2) User manuals

• Pelican carrying case model 1500

• (5) Buck Libra Plus™ LP-12 pumps

• (5) Pieces of 3 ft of vinyl hose

• (5) Luer hose adapters

• (5) Shirt/hose clips

• Non-adjustable tube holder

• (5) Triple pack NiMH batteries

• Quick(5)™ charger 100-240V

• (2) User manuals

• Pelican carrying case model 1500

• (5) Buck Libra Plus™ LP-20 pumps

• (5) Pieces of 3 ft of vinyl hose

• (5) Luer hose adapters

• (5) Shirt/hose clips

• Non-adjustable tube holder

• (5) Triple pack NiMH batteries

• Quick(5)™ charger 100-240V

• (2) User manuals

• Pelican carrying case model 1600

AIR SAMPLING 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM 10
Part Number Description Flow Rate (Total) Power Source APB-906800 Buck Libra Plus™ LP-1 Starter Kit 100 - 600 cc/min 120V APB-946500 Buck Libra Plus™ LP-1 5-Pump Kit 100 - 600 cc/min 120V APB-906200 Buck Libra Plus™ LP-5 Starter Kit 0.8 - 5.0 LPM 120V APB-946200 Buck Libra Plus™ LP-5 5-Pump Kit 0.8 - 5.0 LPM 120V APB-906300 Buck Libra Plus™ LP-7 Starter Kit 3.0 - 7.0 LPM 120V APB-942507 Buck Libra Plus™ LP-7 5-Pump Kit 3.0 - 7.0 LPM 120V APB-906250 Buck Libra Plus™ LP-12 Starter Kit 3.0 - 12.0 LPM 120V APB-942512 Buck Libra Plus™ LP-12 5-Pump Kit 3.0 - 12.0 LPM 120V APB-906700 Buck Libra Plus™ LP-20 Starter Kit 5.0 - 20.0 LPM 120V APB-942520 Buck Libra Plus™ LP-20 5-Pump Kit 5.0 - 20.0 LPM 120V APB-109033 Adjustable Universal Low Flow Holder 5 - 100 cc/minAPB-109030 Adjustable Universal Low Flow Holder 5 - 800 cc/min*230V also available Starter Kit Includes Model Buck Libra Plus™ LP-1, LP-5 & LP-7 Buck Libra Plus™ LP-12 Buck Libra Plus™ LP-20 Includes • Buck Libra Plus™ LP-1, LP-5 or LP-7 pump
3 ft of vinyl hose
Luer
5-Pump Kit Includes Model Buck Libra Plus™ LP-1, LP-5 & LP-7 Buck Libra Plus™ LP-12 Buck Libra Plus™ LP-20

Buck Elite™ Personal Air Sampling Pump

The Buck Elite™ series personal air sampling pump draws air contaminants in through a sampling media such as sorbent tubes, bubble impingers, long duration color detector tubes; to gauge personnel exposure to gases, vapors, particulates, aerosols, etc. It is capable of delivering up to 0.6 LPM. Low flows from 5 - 99 cc/min can be obtained using the optional Low Flow Holder.

Features

• Flow rate:

Buck Elite™-1: 0.005 - 0.6 LPM (total)

5 - 99 cc/min with optional Adjustable Universal Low Flow Holder (APB-109033)

Buck Elite™-5: 0.8 - 5.0 LPM (total)

5 - 799 cc/min with optional Adjustable Universal Low Flow Holder (APB-109030)

Buck Elite™-12: 3.0 -12.0 LPM (total)

50 - 800 cc/min with optional Adjustable Universal Low Flow Holder (APB-109030)

• Capable for data logging and programmable for multiple "Start/ Stop" and duration sampling

• Steel fiber filled Lexan, antistatic, and RFI/EMI-shielded case

• Exclusive electronic circuit board for constant flow control

• "Auto-Restart” within one minute of a flow fault

• High backpressure compensation up to 36” of w.c. @ 300 cc/min

• Flow compensation for filter plugging and battery voltage

• Key pad lock system

• Stainless steel belt clip with built-in tripod connector

• Rechargeable NiMH battery pack

• Certifications: CE EMC Directive (EMCD) 89/336/EEC

Kit

Includes • Buck Elite™-1 pump

• 3 ft of vinyl hose

• Luer hose adapter

• Shirt/hose clip

• Non-Adjustable Low Flow Holder

• Single pack NiMH battery

• Standard 120V charger

• User manual

5-Pump Kit Includes

• Buck Elite™-5 pump

• 3 ft of vinyl hose

• Luer hose adapter

• Shirt/hose clip

• Single pack NiMH battery

• Standard 120V charger

• User manual

Elite™-12

• Buck Elite™-12 pump

• 3 ft of vinyl hose

• Luer hose adapter

• Shirt/hose clip

• Triple pack NiMH battery

• Standard 120V charger

• User manual

Model Buck Elite™-1 Buck Elite™-5 Buck Elite™-12

Includes

• (5) Buck Elite™-1 pumps

• (5) Pieces of 3 ft of vinyl hose

• (5) Luer hose adapters

• (5) Shirt/hose clips

• (5) Non-Adjustable Low Flow Holders

• (5) Single pack NiMH batteries

• Quick(5)™ 100-240V charger

• (2) User manuals

• Pelican carrying case model 1500

• (5) Buck Elite™-5 pumps

• (5) Pieces of 3 ft of vinyl hose

• (5) Luer hose adapters

• (5) Shirt/hose clips

• (5) Single pack NiMH batteries

• Quick(5)™ 100-240V charger

• (2) User manuals

• Pelican carrying case model 1500

• (5) Buck Elite™-12 pumps

• (5) Pieces of 3 ft of vinyl hose

• (5) Luer hose adapters

• (5) Shirt/hose clips

• (5) Triple pack NiMH batteries

• Quick(5)™ 100-240V charger

• (2) User manuals

• Pelican carrying case model 1600

*230V also available

AIR SAMPLING AIR SAMPLING 11 Part Number Description Flow Rate (Total) Power Source APB-908100 Buck Elite™-1 Starter Kit 0.005 - 0.6 LPM 120V APB-947300 Buck Elite™-1 5-Pump Kit 0.005 - 0.6 LPM 120V APB-908000 Buck Elite™-5 Starter Kit 0.8 - 5.0 LPM 120V APB-947200 Buck Elite™-5 5-Pump Kit 0.8 - 5.0 LPM 120V APB-908300 Buck Elite™-12 Starter Kit 3.0 - 12.0 LPM 120V APB-948000 Buck Elite™-12 5-Pump Kit 3.0 - 12.0 LPM 120V APB-109033 Adjustable Universal Low Flow Holder 5 - 100 cc/minAPB-109030 Adjustable Universal Low Flow Holder 5 - 800 cc/min -
Starter
Includes Model Buck Elite™-1 Buck Elite™-5 Buck

Buck Allin™ & Buck Allin™ Plus Intrinsically Safe Personal

Low Flow Air Sampling Pump

The Buck Allin™ & Buck Allin™ Plus series is a personal air sampler suitable for use in locations where flammable gases, vapors, dust, fibers or flying’s are present. The purpose of this pump is to draw air contaminants in through a sampling media such as 25 mm and 37 mm filter cassettes, bubble impingers, long-duration color detector tubes; to gauge personnel exposure to gases, vapors, particulates, aerosols, etc. It is capable of delivering up to 5.0 LPM. Low flows from 5 - 799 cc/min can be obtained using the optional Low Flow Holder.

Features

• Flow rate:

Buck Allin™-1 & Buck Allin™ Plus-1: 0.1 - 0.6 LPM (total)

5 - 99 cc/min with optional Adjustable Universal Low Flow Holder (APB-109030)

Buck Allin™-5 & Buck Allin™ Plus-5: 0.8 - 5.0 LPM (total)

5 - 799 cc/min with optional Adjustable Universal Low Flow Holder (APB-109030)

Buck Allin™-12 & Buck Allin™ Plus-12: 3.0 -12.0 LPM (total)

50 - 2999 cc/min with optional Adjustable Universal Low Flow Holder (APB-109030)

• Buck Allin™ Plus models are capable of data logging and can be programmed for multiple "Start/ Stop" and duration sampling

• Buck Allin™ Plus models allows temperature and barometric pressure compensation in STP mode

• Steel fiber filled Lexan, antistatic, and RFI/EMI-shielded case

• Exclusive electronic circuit board for constant flow control

• "Auto-Restart" within one minute of a flow fault

• High backpressure compensation up to 50" of w.c. @ 2 LPM

• Flow compensation for filter plugging and battery voltage

• Key pad lock system

• Stainless steel belt clip with built-in tripod connector

• Rechargeable NiMH battery pack

• Certifications: UL 913 & CAN/CSA-C22.2 Intrinsically Safe, suitable for use in Class I, II, III, Div 1

Groups A-G, T3 Hazardous Locations

Includes • Buck Allin™-1, Buck Allin™-5 or Buck Allin™-12 pump

• 3 ft of vinyl hose

• Luer hose adapter

• Shirt/hose clip

5-Pump Kit Includes

Model Buck Allin™-1, Buck Allin™-5 & Buck Allin™-12

Includes • (5) Buck Allin™-1, Buck Allin™-5 or Buck Allin™-12 pumps

• (5) Pieces of 3 ft of vinyl hose

• (5) Luer hose adapters

• (5) Shirt/hose clips

• (5) Single pack NiMH batteries

• Single pack NiMH battery

• Standard 120V charger

• User manual

• Buck Allin™ Plus-1, Buck Allin™ Plus-5 or Buck Allin™ Plus-12 pump

• 3 ft of vinyl hose

• Luer hose adapter

• Shirt/hose clip

• Standard 110-240V smart charger kit

• (2) User manuals

• Carrying case

Plus-12

• Low Flow Holder

• Single pack NiMH battery

• Standard 120V charger

• User manual

Buck Allin™ Plus-1, Buck Allin™ Plus-5 & Buck Allin™ Plus-12

• (5) Buck Allin™ Plus-1, Buck Allin™ Plus-5 or Buck Allin™ Plus-12 pumps

• (5) Pieces of 3 ft of vinyl hose

• (5) Luer hose adapters

• (5) Shirt/hose clips

• Low Flow Holder

• (5) Single pack NiMH batteries

• Standard 110-240V smart charger kit

• (2) User manuals

• Carrying case

AIR SAMPLING 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM 12
Part Number Description Flow Rate (Total) Power Source APB-905000 Buck Allin™-1 Starter Kit 0.1 - 0.6 LPM 120V APB-905050 Buck Allin™-1 5-Pump Kit 0.1 - 0.6 LPM 120V APB-905200 Buck Allin™-5 Starter Kit 0.8 - 5.0 LPM 120V APB-905250 Buck Allin™-5 5-Pump Kit 0.8 - 5.0 LPM 120V APB-905400 Buck Allin™-12 Starter Kit 3.0 - 12.0 LPM 120V APB-905450 Buck Allin™-12 5-Pump Kit 3.0 -12.0 LPM 120V APB-905100 Buck Allin™ Plus-1 Starter Kit 0.1 - 0.6 LPM 120V APB-905150 Buck Allin™ Plus-1 5-Pump Kit 0.1 - 0.6 LPM 120V APB-905300 Buck Allin™ Plus-5 Starter Kit 0.8 - 5.0 LPM 120V APB-905340 Buck Allin™ Plus-5 5-Pump Kit 0.8 - 5.0 LPM 120V APB-905500 Buck Allin™ Plus-12 Starter Kit 3.0 - 12.0 LPM 120V APB-905550 Buck Allin™ Plus-12 5-Pump Kit 3.0 - 12.0 LPM 120V APB-109030 Adjustable Universal Low Flow Holder 5 - 800 cc/min*230V also available Starter Kit Includes Model Buck Allin™-1, Buck Allin™-5 & Buck Allin™-12 Buck Allin™ Plus-1, Buck Allin™ Plus-5 & Buck Allin™

Zefon® High Volume Diaphragm Area Sampling Pump

The Zefon® 23 stroke High Volume Diaphragm area sampling pump is an economical workhorses with a flow range of 3 - 14 LPM. Suitable for use with asbestos PCM, TEM, Air-O-Cell® and Via-Cell® cassettes.

Includes

• Zefon® High Volume Diaphragm pump with locking flow control valve

• 10 ft tubing

• Hose barb

• On/Off switch

2-Pump Kit Includes

• (2) Zefon® High Volume Diaphragm pumps with locking flow control valves

• (2) pieces of 10 ft tubing

• (2) Hose barbs

• (2) On/Off switches

• (2) Tripod stands

• Heavy duty carrying case

Available To Rent

- 20 LPM Zefon® Non-Adjustable Medium Flow Field Rotameter

Includes: Hose Barb, Tygon® Tubing & Luer Adapter

ZE-195505 3 - 30 LPM Zefon® Non-Adjustable High Flow Field Rotameter

Includes: Hose Barb, Tygon® Tubing & Luer Adapter

CY-8860-4335 3/8'' O.D. x 1/4'' I.D. Clearflex 60 Non-Phtalate PVC Tubing, 100 ft - -

EMS-200550

Premium Telescopic Sampling Tripod Stand - -

ZE-ZTHV00-KCASE Carrying Case For ZTHV01 Pumps (Holds (2) ZTHV01 Pumps, (2) Stands & Tubing)

*220V also available

*Please refer to page 27 for area pump replacement parts and area pump accessories

New! Now with internal filter/muffler.

No more glass muffler jars!

Zefon® High Volume Rotary Vane Sampling Pump

The Zefon® High Volume Rotary Vane pump is an economical alternative to the Gast brand Rotary Vane pumps with a flow range of 0 - 30 LPM. The workhorses are heavy duty with a 1/10 hp motor that can be used for almost all sampling applications. Suitable for use with asbestos PCM, TEM, Air-O-Cell® and Via-Cell® cassettes along with all viable impactors (ex: Andersen style impactor).

Flow Rates

PCM cassette: 3 - 15 LPM

TEM cassette: 3 - 10 LPM

Air-O-Cell® cassette: 15 LPM

Viable Impactor: 28.3 LPM

Includes:

Includes

• Zefon® High Volume Rotary Vane pump with flow control valve

• 2 1/4" I.D. tubing set

• On/Off switch

Available To Rent

2-Pump Kit Includes

• (2) Zefon® High Volume Rotary Vane pumps with flow control valves

• (2) 2 1/4" I.D. tubing sets

• (2) On/Off switches

• (2) Tripod stands

• Heavy duty carrying case

Non-Phtalate PVC Tubing, 100 ft -EMS-200550 Premium Telescopic Sampling Tripod Stand -ZE-ZHV00-KCASE Carrying Case For ZHV00 Pumps (Holds (2) ZHV00 Pumps, (2) Stands & Tubing) - -

*220V also available

*Please refer to page 29 for area pump replacement parts and area pump accessories

AIR SAMPLING AIR SAMPLING 13
Part Number Description Flow Rate (Total) Power Source ZE-ZHV00 Zefon® High Volume Rotary Vane Pump 0 - 30 LPM 120V ZE- ZHV00-KIT Zefon® High Volume Rotary Vane 2-Pump Kit 0 - 30 LPM 120V ZE-116116 0 - 4 LPM Zefon® Non-Adjustable Low Flow Field Rotameter Includes: Hose Barb, Tygon® Tubing & Luer Adapter -ZE-195380 1 - 20 LPM Zefon® Non-Adjustable Medium Flow Field Rotameter Includes: Hose Barb, Tygon® Tubing & Luer Adapter -ZE-195505 3 - 30 LPM Non-Adjustable High Flow Rotameter
Hose Barb, Tygon® Tubing & Luer Adapter -
Clearflex
CY-8860-4335 3/8'' O.D. x 1/4'' I.D.
60
Part Number Description Flow Rate (Total) Power Source ZE-ZTHV01 Zefon® High Volume Diaphragm Pump 3 - 14 LPM 120V ZE-ZTHV01-KIT Zefon® High Volume Diaphragm 2-Pump Kit 3 - 14 LPM 120V ZE-195380 1
-
-
-
-
-
-

Zefon® Non-Adjustable Field Rotameters

The Zefon® Field Rotameters are a low cost way to measure airflow in air sampling applications. They feature a durable acrylic housing with direct reading scales printed on them. Available in three different flow ranges covering a range of 0.2 through 30 LPM. Operation and maintenance are very simple; only a few common sense precautions must be observed to assure long, trouble-free service.

Features

• Scales are large (average 4" length) and easy to read

• The direct reading scales are hot stamped into the plastic and will not wear off

• Mid-range calibration is established with a master flowmeter, providing an accuracy of ±3%

Includes

• Zefon® Non-Adjustable Field Rotameter (low, medium or high)

• Tygon® tubing

• Hose barb

• Luer adapter

Defender 500 Series

you need in the format you prefer. All you have to do is choose between

you exactly

Defender 510 Defender 520 Defender 530+

BIO-200-510L: 5 - 500 cc/min

BIO-200-510M: 50 - 5,000 cc/min

BIO-200-510H: 300 - 30,000 cc/min

BIO-200-520L: 5 - 500 cc/min

BIO-200-520M: 50 - 5,000 cc/min

BIO-200-520H: 300 - 30,000 cc/min

BIO-200-530L: 5 - 500 cc/min

BIO-200-530M: 50 - 5,000 cc/min

BIO-200-530H: 300 - 30,000 cc/min

AIR SAMPLING 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM 14
Part Number Description Flow Rate (Total) ZE-116116 Zefon® Non-Adjustable Low Flow Field Rotameter 0 - 4 LPM ZE-195380 Zefon® Non-Adjustable Medium Flow Field Rotameter 1 - 20 LPM ZE-195505 Zefon® Non-Adjustable High Flow Field Rotameter 3 - 30 LPM
and Flow Ranges
Model
Volumetric Accuracy 1% 1% 1% Standardized Accuracy N/A N/A 1.2% User Selectable Measurement Units Volumetric ml/min, L/min, cc/min, cf/min ml/min, L/min, cc/min, cf/min ml/min, L/min, cc/min, cf/min Standardized N/A N/A smL/min, sL/min, scc/min, scf/min Temperature N/A oC oF oC oF Pressure N/A mmHg, PSI, kPa mmHg, PSI, kPa Temperature and Pressure Sensor No Yes, in flow steam Yes, in flow steam Pressure Accuracy N/A 3.5 mmHg (typical) 7.0 mm (max) 3.5 mmHg (typical) 7.0 mm (max) Temperature Accuracy N/A 0.8oC (typical) 1.3oC (max) 0.8oC (typical) 1.3oC (max) Accurate, Reliable & Portable Primary Calibrators for Fast Calibration of Air Sampling Pumps!
calibrate
continuous measurements
510, the 520 or the 530. Defender 510 Volumetric Primary Flow Standard Defender 520 Enhanced Volumetric Primary Flow Standard Defender 530+ Standardized & Volumetric Primary Flow Standard Available To Rent ASK FOR YOUR FREE RENTAL CATALOG TODAY Call our toll free: 1-888-287-3732 Available To Rent
Instantly
your air samplers using Quick Start - there is no preparation involved, no messy soap bubble solutions. Alternatively, set your Defender to take hands-free,
while you quickly set the flow rate on your pumps. Defender’s many user-selectable options makes customizing your calibrations easy, giving
what
the

Three Flow Cells Available; Low, Standard & High

Gilian® Gilibrator-2

The Gilian® Gilibrator-2 primary standard accuracy and performance validation for sampling pump airflows from 1 cc/min - 30 LPM.

Features

• Flow rate:

Low Flow Cell: 1 - 250 cc/min (total)

Standard Flow Cell: 20 - 6,000 cc/min (total)

High Flow Cell: 2 - 30 LPM (total)

• Consists of an electronic Gilibrator-2 base which is used with any of three sizes of flow cells

• Cells use a twist-on bayonet design for quick and easy mounting to the base

• These interchangeable cells generate perfect bubble films at the touch of a button

• Infrared sensors read the bubble flow rate, which is then calculated and displayed

• DC power source with internal battery pack

• Certified for accuracy and traceable to NIST

Low, Standard & High Flow Cell Kit Includes

• Control base

• Flow cell (low, standard or high)

• Tubing

• Soap solution with dispenser

• DC charger/AC power supply

• Hard shell carry case

Deluxe Cell Kit Includes

• Control base

• Three interchangeable cells for low, standard and high flow rates

• Tubing

• Soap solution with dispenser

• DC charger/AC power supply

• Hard shell carry case

Zefon® DigiCal™ Flow Calibrator

The Zefon® DigiCal™ Flow Calibrator provides instantaneous calibration for instruments like the Zefon® Escort® LC pump or the secondary flow standard inside the Escort ELF® sampling pumps. Just press the plunger and the DigiCal™ calibrator does the work. Its unique flow cell replaces conventional bubble tubes and makes calibration easier. The DigiCal™ Calibrator achieves extreme accuracy by utilizing a computerized flow meter that provides instantaneous flow readouts on a digital display.

Features

• Flow rate:

5: 1 - 6,000 cc/min (total)

DigiCal™ 30: 0.1 - 30 LPM (total)

• ± 0.5% accuracy

• Microprocessor controlled to provide fast, accurate, repeatable measurements

• Work at any altitude without correction

• Instant readout of volumetric flow

AIR SAMPLING AIR SAMPLING 15
Part Number Description Flow Rate (Total) GIL-800272 Gilian® Gilibrator-2 Low Flow Cell Kit With US Cord 1 - 250 cc/min GIL-800271 Gilian® Gilibrator-2 Standard Flow Cell Kit With US Cord 20 - 6,000 cc/min
Gilian® Gilibrator-2
2
GIL-801804 Gilian® Gilibrator-2 Deluxe Cell Kit With All Three Cell Sizes & US Cord 1 - 250 cc/min, 20 - 6000 cc/min, 2 - 30 LPM GIL-800450 Soap
GIL-800270
High Flow Cell Kit With US Cord
- 30 LPM
Solution Flow Cell For Gilian® Gilibrator-2 Calibrator, 8 oz -
Zefon®
Zefon
DigiCal™
®
Part Number Description Flow Rate (total) Power Source ZE-655101 Zefon® DigiCal™ 5 Flow Calibrator 1 - 6,000 cc/min 110V ZE-655130 Zefon® DigiCal™ 30 Flow Calibrator 0.1 - 30 LPM 110V ZE-655273 Soap Bubble Solution For Zefon® DigiCalTM Flow Calibrator, 8 oz -ZE-ZA0122 Pelican 1400 Carrying Case With Pick-N-Pluck Foam -Includes • Zefon® DigiCal™ Flow Calibrator • Soap solution • Dispenser bottle • Charger • User manual

Zefon® Bio-Pump® Plus

The Zefon® Bio-Pump® Plus is the smallest, lightest and easiest to use portable, battery-powered IAQ pumps designed for exclusive use with Air-O-Cell® and Via-Cell® cassettes at a flow rate of 15 LPM.

Features

• Real time display showing actual run time

• Programmable sample time (allows unattended operation)

• "Sample Complete" audible & visual indicators

• "Quick Sample" operation

• Long Lasting NiMH battery provides approx. 8 hours of continuous run time or approx. 100 5-minute samples

Model Zefon® Bio-Pump® Plus Kit Zefon® Bio-Pump® Plus Pro Kit Zefon

Includes • Zefon® Bio-Pump® Plus pump

• Air flow indicator

• (10) Air-O-Cell® cassettes

• Charger

• Warranty card

• User manual

• Carrying case

• Zefon® Bio-Pump® Plus pump

• Air flow indicator

• (10) Air-O-Cell® cassettes

• (25) Bio-Tape™ slides

• Bioisolation filter

• Tripod stand

• Charger

• Warranty card

• User manual

• Carrying case

• Zefon

• Air flow indicator

• (10) Air-O-Cell® cassettes

• TSI 4046 calibrator kit

• Charger

• Warranty card

• User manual

• Carrying case

Zefon® Z-Lite™ IAQ Mold Sampling Starter Kits

The Zefon® Z-Lite™ kits are an easy, convenient way to get everything you need to begin sampling for mold. It is a low maintenance-oscillating pump designed for use with all mold sampling cassettes and impactors.

Features

• Flow rate: 3 - 33 LPM

• Built-in adjustable flow meter/regulator

• Rubber suction cup feet to prevent movement while in use

Includes • Zefon® Z-Lite™ pump with integrated combination flow meter/regulator valve

• Tubing

• (10) Air-O-Cell® cassettes

• Bioisolation filter

• Tripod stand

• Basic set-up and user instructions

• Toolbox style carrying case

• Zefon® Z-Lite™ pump with integrated combination flow meter/regulator valve

• Tubing

• (20) Air-O-Cell® cassettes

• (25) Bio-Tape™ slides

• (10) Mold swabs

• Bioisolation filter

• Tripod stand

• Basic set-up and user instructions

• Toolbox style carrying case

• Zefon® Z-Lite™ pump with integrated combination flow meter/regulator valve

• Tubing

• (50) Air-O-Cell® cassettes

• (50) Bio-Tape™ slides

• (50) Mold swabs

• (10) Inner wall attachments

• Bioisolation filter

• Tripod stand

• Basic set-up and user instructions

• Toolbox style carrying case

AIR SAMPLING 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM 16
Model Basic Kit Deluxe Kit Ultimate Kit
Part Number Description Flow Rate (Total) Sampling Media Power Source ZE-Z-LITE-BMKIT Zefon® Z-Lite™ IAQ Basic Mold Sampling Starter Kit 3 - 33 LPM (10) Air-O-Cell® Cassettes 120V ZE-Z-LITE-DMKIT Zefon® Z-Lite™ IAQ Deluxe Mold Sampling Starter Kit 3 - 33 LPM (20) Air-O-Cell® Cassettes (25) Bio-Tape™ Slides (10) Mold Swabs 120V ZE-Z-LITE-UMKIT Z-Lite™ IAQ Ultimate Mold Sampling Starter Kit 3 - 33 LPM (50) Air-O-Cell® Cassettes (50) Bio-Tape™ Slides (50) Mold Swabs (10) Inner Wall Attachments 120V * 230V also available Part Number Description Flow Rate (Total) Sampling Media Power Source ZE-ZBP-205 Zefon® Bio-Pump® Plus With 110-230V Charger With North American Plug 15 LPM (10) Air-O-Cell® Cassettes 120V ZE-ZBP-PROKIT-PLUS Zefon® Bio-Pump® Plus Pro Kit With Accessories 15 LPM (10) Air-O-Cell® Cassettes (25) Bio-Tape™ Slides 120V ZE-ZBP-205-CKIT Zefon® Bio-Pump® Plus With TSI 4046 Calibrator Kit 15 LPM (10) Air-O-Cell® Cassettes 120V ZE-ZA0047 Bioisolation Filter For Zefon® Bio-Pump® Plus - -ZE-ZA0043 Zefon® Heavy Duty Tripod Stand For Zefon Bio-Pump® Plus - -* 230V also available

Buck Bio-Series Pumps

The Buck Bio-Series pumps are simple to operate and provides a selectable, continuous, and constant sample flowrate. Its quiet operation allows unobtrusive sampling in IAQ, medical, clean room, public, and residential building applications. The front key pad is organized into three functional key groups: Power (ONOFF), Timing (1, 2, 5, 10 minute samples) and Calibration (cal mode, increase flow, decrease flow). End of sample notice is provided by the lit LED "Complete" and three short beep.

Buck BioAire™ Bioaerosol Sampling Pump

Features

• Flow rate: 5 - 20 LPM

• Small, lightweight, and compact

• Accepts both Allergenco-D or Air-O-Cell® cassettes

• NiCad batteries with 6 - 8 hours continuous run time at 15 LPM

• Convenient timer for 1, 2, 5, 10 minute samples and continuous mode

• End-of-cycle audible & visual

• Easy keypad calibration without tools

Includes

• Buck BioAire™ pump

• Calibration rotameter assembly (APB-706100)

• Standard smart 120V charger

• User manual

Buck BioSlide™ Biocontaminent Sampling Pump

Features

• Flow rate: 10 - 20 LPM

• Small, lightweight, and compact

• Accepts generic greased slides

• NiCad batteries with 5 - 6 hours continuous run time at 15 LPM

• End-of-cycle and battery level audible & visual

• Tripod mount for area sampling

Includes

• Buck BioSlide™ pump

• Calibration rotameter assembly (APB-706100)

• Standard smart 120V charger

• User manual

Buck Bio-Culture™ Biocontaminent Sampling Pump

Features

• Flow rate: 30 - 120 LPM

• Holds 90 mm agar petri dish

• 380 holes - 1 mm diameter

• Timing routine of 1, 2, 5 & 10 minutes

• Tripod mount to allow 90o sampling

• Sampling head is easily sterilized with gas torch or autoclave

• Four times the flow rate of an Anderson sampler

Includes

• Buck Bio-Culture™ pump

• Pencil torch

• Tripod

• Standard smart 120V charger

• User manual

• Carrying case

AIR SAMPLING AIR SAMPLING 17
Part Number Description Flow Rate (Total) Power Source APB-706000 Buck BioAire™ Pump Model B520 5 - 20 LPM 120V APB-108000 Durable Hard Plastic Carrying Case With Foam Insert -Part Number Description Flow Rate (Total) Power Source APB-707000 Buck BioSlide™ Pump Model B1020 10 - 20 LPM 120V APB-108000 Durable Hard Plastic Carrying Case With Foam Insert -Part Number Description Flow Rate (Total) Power Source APB-708000 Buck Bio-Culture™ Pump, Model B30120 30 - 120 LPM 120V APB-708500 Calibration Head For Buck Bio-Culture™ Pump - -

MicroflowTM α Microbiological Air Sampler

This instrument has been developed for airborne biological contaminants sampling in order to access the level of biocontamination in critical places (ex: clean rooms, operating rooms, pharmaceutical production plants, food and cosmetic industries, water purification plants, landfills, etc.) and in normal working life situations and not (air conditioning and ventilation controls).

MicroflowTM α allows a wide range of airborne bio-contaminant sampling by impacting on agar plates (60 mm + 2 mm contact plate or 90 mm + 2 mm petri dish).

Features

• Flow rate: 30 - 60 - 90 - 100 - 120 LPM

• Used with:

60 + 2 mm contact plate (MicroflowTM α 60)

90 + 2 mm petri dish (MicroflowTM α 90/C)

Both with contact plate and petri dish (MicroflowTM α 60-90/C)

• NiMH rechargeable battery, without memory effect

• Silent microprocessor controlled fan to ensure maximum reliability on the sampled air volume

• Compensation airflow system (in compensated models)

• Low battery control and alarm

• Prompts in 5 languages: English, French, German, Spanish, Italian & functions are "step-by-step" visualized

• Delay start

•Total volume of sampled air programmable from 1 up to 2000 L, with 1 L steps

•Manual sampling for air volumes greater than 2000 L

Includes • MicroflowTM α sampler

• IR remote control

• Pencil torch

• Additional 60 mm aluminum sampling head

• Base for sampler vertical positioning

• Battery charger

• Calibration report

• Warranty card

• User manual

• Carrying case

AQ-G.1117-A

• Sequential sampling also as required by ISPESL guidelines

• Storing and displayed up to 99 samplings, with record of progressive n number, date, hour, sampling volume or time, flow rate, type of sampling (manual, sequential, programmable)

• USB port to download data to a PC (optional)

• Calibration control function (with optional calibration kit)

• Remote switch with infrared rays control

• Vertical or horizontal sampling (90° and 180°)

• Prepared for mounting on photographic tripod

• MicroflowTM α sampler

• IR remote control

• Pencil torch

• Additional 90 mm aluminum sampling head

• Base for sampler vertical positioning

• Battery charger

• Calibration report

• Warranty card

• User manual

• Carrying case

• MicroflowTM α sampler

• IR remote control

• Pencil torch

• 60 & 90 mm aluminum head assembly

• Base for sampler vertical positioning

• Battery charger

• Calibration report

• Warranty card

• User manual

• Carrying case

Includes:

Includes: Data Transmission & Data Management Software (In Compliance With UNICHIM No.1962)

(Note: Data download requires a structural modification. In case of later purchase, MicroFlow™ α must be returned to Aquaria S.R.L. for software installation.)

AIR SAMPLING 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM 18
Part Number Description Flow Rate (Total) Power Source AQ-G.1004 MicroFlow™ α Kit 60 (For Use With Contact Plates 60 mm ± 2 mm) 30 - 60 - 90 - 100 - 120 LPM 120V AQ-G.1004-SS MicroFlow™ α Stainless Steel Kit 60 (For Use With Contact Plates 60 mm ± 2 mm) 30 - 60 - 90 - 100 - 120 LPM 120V AQ-G.1015 MicroFlow™ α Kit 90/C (For Use With 90 mm ± 2 mm Petri Dish), With Flow Compensation 30 - 60 - 90 - 100 - 120 LPM 120V AQ-G.1015-SS MicroFlow™ α Stainless Steel Kit 90/C (For Use With 90 mm ± 2 mm Petri Dish), With Flow Compensation 30 - 60 - 90 - 100 - 120 LPM 120V AQ-G.1027 MicroFlow™ α Kit 60-90/C (For Use With 60 mm ± 2 mm Contact Plate & With 90 mm ± 2 mm Petri Dishes), With Flow Compensation 30 - 60 - 90 - 100 - 120 LPM 120V AQ-G.1120 Digital Calibration Kit
MicroFlow™
For
α
-
Digital Differential Pressure Meter, Fitting Tubes & Conversion Table -
USB
Interface For Data Download To PC
- -
3 ft.
-
AQ-A.2004
Master Type Stand -
Model MicroflowTM α 60 Kit MicroflowTM α 90/C Kit MicroflowTM α 60-90/C Kit

Zefon® A6 Impactor

The Zefon® A6 Impactor sampler is an exact replica of the popular Andersen N-6 single stage impactor. The Zefon® A6 impactor is an aluminum device consisting of a top inlet "cone", a sampling head impactor stage which contains 400 precision drilled holes and a base section, which holds the agar media. The sampler is held together by three spring clamps and sealed with two o-ring gaskets. When air is drawn through the sampler, multiple jets of air direct any airborne particles toward the surface of the agar collection media surface where the particles are impacted and collected. The agar collection media is then sent to a laboratory for analysis.

Features

• Flow rate: 28.3 LPM (1 ACFM)

• Particle size cut point: 0.65 μm

• Sampler size: 4.25" diameter, 2.87" height, 1.23 lbs weight

• Material: aircraft grade aluminum

• Uses 100 mm x 15 mm petri dishes

• Certifications: meets NIOSH method 0800 & 0801 requirements

For "In-Line" Impactor Calibration -

Zefon® Heavy Duty Tripod Stand For Zefon® A6 Impactor -

Inf

Zne

When Using A Zefon® A6 Impactor

Accurate results when using a Zefon® A6 Impactor depend on proper measurement of flow through the impactor inlet. This can be best measured using a bubble or dry piston flow calibrator traceable to NIST standard (such as a Bios Defender or Gilian® Gilibrator) set up with the Zefon® A6 impactor "in-line". To your impactor "in-line", be sure to order the Z-A6-CAL adapter, which fits over the impactor inlet and allows tubing to be connected to it.

Includes

• Zefon® A6 Impactor

• Pump flow meter

• 1/4" I.D. tubing

• Tripod stand

• Carrying case

A Static Conductive Replica Of The 10 mm Sensidyne "Dorr-Oliver" Nylon Cyclone

Zefon® 10 mm Static Conductive Nylon Cyclone

The Zefon® 10 mm Conductive Nylon Cyclone (Sensidyne "Dorr-Oliver" style) is used in conjunction with 37 mm filter cassettes to separate dust particles by size with the respirable particles being collected on the filter and larger particles being removed. The collection efficiency curve meets the standards set forth by ACGIH/ISO/CEN for a respirable curve with a median 50% cut point of 4 μm when operated at a flow rate of 1.7 LPM.

Features

rate:

convention: 1.7 LPM with a nominal particle diameter of 4.0 μm Other applications: 2 LPM with a nominal particle diameter of 3.5 μm

• Conductive, eliminates any possible bias in sampling results from static charging

• Lightweight design only 3.6 oz for the complete assembly including cassette and holder

• Certifications: meets NIOSH requirements for 10 mm nylon cyclones as specified in 0600 for nuisance dust & 7500, 7501, 7601 & 7602 for silica dust

ZE-ZA0082

AIR SAMPLING AIR SAMPLING 19
Flow
ISO/ACGIH/CEN
Part Number Description Power Source ZE-Z-A6 Zefon® A6 Impactor Only 120V ZE-ZHV00-A6-KIT Zefon® A6 Impactor Kit 120V ZE-Z-A6-CAL
Part Number Description ZE-ZA0080 Zefon® 10 mm Conductive Nylon Cyclone ZE-ZA0081 Zefon® 10 mm Conductive Nylon Cyclone With Cassette/Cyclone Holder ZE-ZA0063 Zefon® 1 Liter Cyclone Calibration Jar For Aluminum Cyclone & Zefon® Conductive Nylon Cyclone ZE-ZA0085 Zefon® 2 Liter Cyclone Calibration Jar
Zefon® Universal
Adapter
ZE-ZA0043
For Zefon® & Sensidyne "Dorr-Oliver" Nylon Cyclones) ZE-ZA0061
Cassette/Cyclone Holder Only
Replacement
Grit Pots, 25/Pack
The cyclone must be used in conjuction with a cassette/cyclone holder. Compatible with both the Zefon® cassette/cyclone holder ZE-ZA0061 or the SKC holder SK-225-1.
10 mm Nylon Cyclone Efficiency Curve Comparison at 1.7 lpm Particle Size (µ) Zefon 10 mm Heavy Duty Sensidyne TSI Zefon 10 mm Conductive
Internal Zefon performance tests with all 4 cyclones under identical conditions Collection Efficiency (%)
Source:

10 mm Sensidyne "Dorr-Oliver" Nylon Cyclone Sampler For Respirable Dust & Silica

The "Dorr-Oliver" 10 mm Nylon Cyclone is used in conjunction with 37 mm filter cassettes to separate dust particles by size with the respirable particles being collected on the filter and larger particles being removed. The collection efficiency curve meets the standards set forth by ACGIH/ISO/CEN for a respirable curve with a median 50% cut point of 4 μm when operated at a flow rate of 1.7 LPM.

Features

• Flow rate:

ISO/ACGIH/CEN convention: 1.7 LPM with a nominal particle diameter of 4.0 μm

Other applications: 2 LPM with a nominal particle diameter of 3.5 μm

• Certification: meets NIOSH requirements for 10 mm nylon cyclones as specified in 0600 for nuisance dust & 7500, 7501, 7601 & 7602 for silica dust

Part Number Description

GIL-800061 10 mm Sensidyne "Dorr-Oliver" Nylon Cyclone

GIL-7013376 Cyclone Calibration Jar For 10 mm Sensidyne "Dorr-Oliver" Nylon Cyclone & Inhalable Dust Sampler Head

GIL-200159 Replacement Cyclone Grit Pot For 10 mm Sensidyne "Dorr-Oliver" Nylon Cyclone

Inf Z ne Cyclone Calibration

Jar

When ordering a traditional Sensisyne "Dorr-Oliver" cyclone sampler, be sure to also order a Cyclone Calibration Jar GIL-7013376. Since a Sensidyne "Dorr-Oliver" cyclone has only a single hose connection, this jar allows proper placement of the cyclone filter between the sampling pump and the calibrator device.

A replica of the SKC Aluminum Cyclone

Zefon® Aluminum Cyclone For Respirable Dust

The Zefon® Respirable Dust Aluminum Cyclone is used in conjunction with 25 mm or 37 mm 3-piece filter cassettes to separate and remove larger particles from the respirable particles collected on the cassette’s filter. The collection efficiency curve meets the standards set forth by ACGIH/ISO/CEN for a respirable curve with a median 50% cut point of 4 μm at 2.5 LPM flowrate. A cyclone holder and 25 mm or 37 mm 3-piece filter cassette are required for use of the Zefon® Aluminum Cyclone.

Features

• Aluminum construction is static conductive, eliminating interference

• Lightweight design only 1.1 oz

• Fully interchangeable with SKC Aluminum Cyclone

• Certification: specified in NIOSH method 0600 for respirable particulates & NIOSH 7500 for silica, crystalline

GIL-801124 Replacement Cylcone Vortex Finder Accessory For 10 mm Sensidyne "Dorr-Oliver" Nylon Cyclone Part Number

ZE-ZA0060 Zefon® 37 mm Aluminum Cyclone For Respirable Dust

ZE-ZA0075 Zefon® 25 mm Aluminum Cyclone For Respirable Dust

ZE-ZA0062 Zefon® 37 mm Aluminum Cyclone For Respirable Dust With Holder

ZE-ZA0076 Zefon® 25 mm Aluminum Cyclone For Respirable Dust With Holder

ZE-ZA0063 Zefon® 1 Liter Cyclone Calibration Jar For Zefon® Conductive Nylon Cyclone & Aluminum Cyclone

ZE-ZA0085 Zefon® 2 Liter Cyclone Calibration Jar For Zefon® & Sensidyne "Dorr-Oliver" Nylon Cyclones

ZE-ZA0061 Zefon® Universal Cassette/Cyclone Holder Only

ZE-ZA0066 Replacement Grit Pots For Aluminum Cyclone, 25/Pack

ZE-ZA0067 Replacement O-Rings For Aluminum Cyclone, 5/Pack

with cassette installed in holder

AIR SAMPLING 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM 20
Description
Shown

Zefon® Aluminum Cyclone Calibration Adapter

A chamber specifically designed to fit over the Zefon® Aluminum Cyclone and connect 1/4" I.D. tubing for flow calibration. This provides the best calibration option by taking an actual measurement as close to the cyclone inlet as possible. Chamber fits both Zefon® brand and SKC brand 37 mm and 25 mm aluminum cyclones.

Part Number

Zefon® Calibration Jar

ZE-ZA0011 Zefon® Aluminum Cyclone Calibration Adapter Part

The Zefon® Cyclone Calibration Jar is a container with all the proper fittings and connections to calibrate personal sampling pumps with the Zefon®, SKC, or Sensidyne "Dorr-Oliver" Cyclones and inhalable dust samplers.

ZE-ZA0063

ZE-ZA0085

® 2 Liter Cyclone Calibration Jar For Zefon® & Sensidyne “Dorr-Oliver” Nylon Cyclones

Zefon® Bio-Tape™ - Standardized Method For Surface Sampling

Zefon® Bio-Tape™ provides a standardized surface sampling method used for the determination of possible microbial, bioaerosol, and inorganic dust contamination. It provides the ability to quickly take a sample and measure the relative degree of contamination. It is especially useful when sampling valuable or non-transportable materials and is very effective on smooth areas of concern.

• Provides sample consistency

• Individually serialized for traceability

• Prevents cross contamination

• Eliminates problems of placing tape in a zip bag, or broken glass slides

• Samples may be archived by the laboratory for later review

• Requires less laboratory prep time

Zefon® Sterile Surface Mold Swabs

Zefon® Sterile Surface Swabs are an easy way to sample suspect areas for mold contamination. Simply swab the suspect area and submit to a laboratory where the sample will be cultured and the type of mold identified. Each swab comes in an easy to use container for sampling, transport and storage.

AIR SAMPLING AIR SAMPLING 21
Description
Description
Number
Zefon
® 1 Liter Cyclone Calibration Jar For Zefon® Conductive Nylon Cyclone & Aluminum Cyclone
Zefon
Part Number Description ZE-BT0025 Zefon®Bio-Tape™ Slides, 25/Box ZE-BT0050 Zefon®Bio-Tape™ Slides, 50/Box ZE-BT0500 Zefon®Bio-Tape™ Slides, 500/Box * Limited shelf life
Part Number Description ZE-ZA0020 Zefon® Mold Swab Kit ZE-ZA0023 Zefon® Sterile Mold Surface Swabs * Limited shelf life Includes • (10) Sterile Surface Mold Swabs • (10) Sterile 10 cm x 5 cm templates Features
AIR • WATER • SOIL www.ereinc.com VIEW OUR NEW CATALOGS

Zefon® Preloaded Air Sampling Filter Cassettes

Zefon® offers a complete line of air sampling cassettes manufactured to meet all applicable NIOSH, OSHA, and EPA standards. All cassette housings are manufactured in-house from polystyrene or polypropylene and are available in two or three piece configurations. Cassettes are individually assembled and preloaded under stringent quality assurance standards with only the finest quality membrane and support pads.

Features

• Fully assembled, preloaded and ready to use

• Leak free construction eliminates sample loss

• Configurations available to conform with most NIOSH standards that require filter cassettes

• Wide selection of filter membrane types

• Available with Zefon® Solu-Sert™ or Gravi-Sert™ filter capsules installed

• Sterile models available for fluid contamination sampling and microbiological analysis

• Ultra Pure PTFE models available for pharmaceutical compound sampling

• Custom configurations available

*Limited shelf life

AIR SAMPLING 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM 22 PVC Preloaded Filter Cassettes Part Number Diameter Pore Size Housing Style Notes Quantity ZE-525PVC 25 mm 5.0 μm 2-Piece, Styrene – 50/Box ZE-5M52P 25 mm 5.0 μm 2-Piece, Styrene, Banded Match-Weighed Filters 50/Box ZE-5P52P 25 mm 5.0 μm 2-Piece, Styrene, Banded Pre-Weighed Filter 50/Box ZE-535PVC 25 mm 5.0 μm 3-Piece, Styrene – 50/Box ZE-5M53P 25 mm 5.0 μm 3-Piece, Styrene, Banded Match-Weighed Filters 50/Box ZE-5P53P 25 mm 5.0 μm 3-Piece, Styrene, Banded Pre-Weighed Filter 50/Box ZE-725PVC 37 mm 5.0 μm 2-Piece, Styrene – 50/Box ZE-7M52P 37 mm 5.0 μm 2-Piece, Styrene, Banded Match-Weighed Filters 50/Box ZE-7P52P 37 mm 5.0 μm 2-Piece, Styrene, Banded Pre-Weighed Filter 50/Box ZE-735PVC 37 mm 5.0 μm 3-Piece, Styrene – 50/Box ZE-7M53P 37 mm 5.0 μm 3-Piece, Styrene, Banded Match-Weighed Filters 50/Box ZE-7P53P 37 mm 5.0 μm 3-Piece, Styrene, Banded Pre-Weighed Filter 50/Box *Limited shelf life MCE Preloaded Filter Cassettes Part Number Diameter Pore Size Housing Style Notes Quantity ZE-528MCE 25 mm 0.8 μm 2-Piece, Styrene – 50/Box ZE-538MCE 25 mm 0.8 μm 3-Piece, Styrene – 50/Box ZE-7345MCE 37 mm 0.45 μm 3-Piece, Styrene – 50/Box ZE-PS7345MCE 37 mm 0.45 μm 3-Piece, Styrene Sterile 50/Box ZE-734MCECF 37 mm 0.45 μm 3-Piece, Conductive – 50/Box ZE-7345MCECF 37 mm 0.45 μm + 5.0 μm 3-Piece, Conductive – 50/Box ZE-7445MCE-C 37 mm 0.45 μm 4-Piece, Styrene Filter Placed Between Spacer Rings 50/Box ZE-7445MCECF-C 37 mm 0.45 μm 4-Piece, Conductive Filter Placed Between Spacer Rings 50/Box ZE-728MCE 37 mm 0.8 μm 2-Piece, Styrene – 50/Box ZE-729MCE 37 mm 0.8 μm 2-Piece, Styrene, Banded – 50/Box ZE-7M92M 37 mm 0.8 μm 2-Piece, Styrene, Banded Match-Weighed Filters 50/Box ZE-738MCE 37 mm 0.8 μm 3-Piece, Styrene – 50/Box ZE-PS738MCE 37 mm 0.8 μm 3-Piece, Styrene Sterile 50/Box ZE-738MCECF 37 mm 0.8 μm 3-Piece, Conductive – 50/Box ZE-739MCE 37 mm 0.8 μm 3-Piece, Styrene, Banded – 50/Box ZE-7M93M 37 mm 0.8 μm 3-Piece, Styrene, Banded Match-Weighed Filters 50/Box ZE-7M93M-SB 37 mm 0.8 μm 3-Piece, Styrene, Banded Match-Weighed Filters With Security Band 50/Box

Gravimetric Pre-Weighed Cassettes

Gravimetric analysis samples require filters to be weighed both before and after sampling to determine the amount of contaminate collected. Zefon® pre-weighed cassettes eliminate the inconvenience of pre-weighing filters by providing the filter weight on each cassette prior to sampling.

Features

• Each cassette is labeled with weight and serial number

• Use of pure homopolymer PVC filters provides excellent weight stability

• PVC filters specially designed with no silica and low ash properties

Inf Z ne

Using A Match-Weight Cassette

Using A Pre-Weighed Cassette

Environmental conditions can have a significant effect on filter weight readings. When using Zefon® pre-weighed cassettes, it is important that the post sample weighing is performed under the same environmental conditions used at the Zefon® factory. Those conditions are set at a temperature of 68°F and a relative humidity of 50%.

Using Zefon® pre-weighed cassettes does not comply with OSHA directives which require both the "tare weight" and "secondary weight" to be performed on the same microbalance and environmental conditions. If complying with this directive is a concern, match-weighed cassettes are a good alternative way to save time and still comply with the directive.

The weight tolerance of match weighed filters references the maximum difference in weight from the test (top) filter and the control (bottom) filter. A stated tolerance of 50 μg means that the control filter may differ in weight no more than 50 μg from the test filter. This is important to know during post sample weighing as the weight tolerance of the 2 filters needs to be considered when calculating results.

During manufacture, filters with matched weights (within the given tolerance) are inserted into the cassette in random order. Thus, it is possible for the control filter to weigh more than the test filter before sampling (within the given tolerance). If the control filter still weighs more after sampling, a sample likely was not collected. Please check your equipment for proper operation and pump flow.

Gravimetric Match-Weighed Cassettes

Gravimetric analysis samples require filters to be weighed both before and after sampling to determine the amount of contaminate collected. Zefon® matchweighed cassettes eliminate the need of weighing filters before sampling by providing two filters which are matched in weight. The top filter collects particulate and the bottom filter serves as a control. After sampling, both filters are weighed and the difference in weight equals the amount of contaminate collected.

Matched-Weighed Configuration

Features

• Each cassette labeled with serial number

• Color coded to indicate filter type

• Preloaded - ready to use

*Limited shelf life

AIR SAMPLING AIR SAMPLING 23 Part Number Diameter Pore Size Housing Style Weight Tolerance Quantity ZE-5P52P 25 mm 5.0 μm 2-Piece Styrene 15 μg 50/Box ZE-5P52P-GS 25 mm 5.0 μm Gravi-Sert™ 2-Piece Styrene 15 μg 50/Box ZE-5P53P 25 mm 5.0 μm 3-Piece Styrene 15 μg 50/Box ZE-7P52P 37 mm 5.0 μm 2-Piece Styrene 15 μg 50/Box ZE-7P53P 37 mm 5.0 μm 3-Piece Styrene 15 μg 50/Box *Limited shelf life Part Number Filter Diameter Pore Size Housing Style Band Color Weight Tolerance Quantity ZE-5M92M MCE 25 mm 0.8 μm 2-Piece Styrene Blue 50 μg 50/Box ZE-5M93M MCE 25 mm 0.8 μm 3-Piece Styrene Blue 50 μg 50/Box ZE-7M92M MCE 37 mm 0.8 μm 2-Piece Styrene Blue 50 μg 50/Box ZE-7M92M-R-SB MCE 37 mm 0.8 μm 2-Piece Styrene Blue With Security Band 50 μg 50/Box ZE-7M92M-TN MCE 37 mm 0.8 μm 2-Piece Tenite, Meets Requirement Of ASTM D2276 None 50 μg 50/Box ZE-7M93M MCE 37 mm 0.8 μm 3-Piece Styrene Blue 50 μg 50/Box ZE-5M52P PVC 25 mm 5.0 μm 2-Piece Styrene Red 20 μg 50/Box ZE-5M53P PVC 25 mm 5.0 μm 3-Piece Styrene Red 20 μg 50/Box ZE-7M52P PVC 37 mm 5.0 μm 2-Piece Styrene Red 20 μg 50/Box ZE-7M53P PVC 37 mm 5.0 μm 3-Piece Styrene Red 20 μg 50/Box

Zefon® 25 mm PCM Preloaded Filter Asbestos Sampling Cassettes

Zefon® and EMS offer PCM 25 mm conductive air sampling cassettes designed and manufactured to meet all applicable NIOSH, AHERA, OSHA, and EPA standards. The cassette housings are manufactured in-house from high quality polypropylene and are individually assembled and preloaded under stringent quality control standards.

Features

• 2" conductive extension cowl

• 3-piece housing

• Meets regulatory requirements

• Each cassette comes with a unique serial number

*Limited shelf life

Zefon® Air-O-Cell® Bioaerosol Cassettes

The Zefon® Air-O-Cell® is a unique sampling cassette designed for the rapid collection of a wide range of both viable and non-viable aero-allergens including mold spores, pollen, insect parts, skin cells, fibers and inorganic particulate.

These cassettes can be used with any standard off-the-shelf sampling pump capable of drawing 15 LPM open flow, including the Zefon® Bio-Pump® Plus, a convenient battery powered hand-held pump for ease of sampling.

Features

• Industry proven & accepted

• Independently validated

• Laboratory preferred, easy to analyze

• Proven results

• No sample loss during shipping & handling

• Pre-loaded, no slides to prepare

*Limited

Inner Wall Sampling Attachments

Zefon

To

AIR SAMPLING 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM 24
Part Number Diameter Pore Size Housing Style Notes Quantity ZE-Z008BA 25 mm 0.8 μm 3-Piece With 2" Conductive Cowl Asbestos PCM, Banded 50/Box EMS-900103 25 mm 0.8 μm 3-Piece With 2" Conductive Cowl Asbestos PCM, Banded 50/Box
Inf Z ne
® Inner Wall Attachments are used in conjunction with Air-O-Cell®, MoldSNAP™, or Via-Cell® cassettes to non-destructively access microbial contamination in a wall cavity, equipment for proper operation and pump flow.
hole (preferably
tubing attachment to the cassette
the tube
wall. Part Number Description Quantity ZE-AOC050 Air-O-Cell® Air Sampling Cassettes 50/Box ZE-AOCCAL Air-O-Cell® In-Line Calibration Adapter Each ZE-AOC-WS10 Air-O-Cell® Inner Wall Samplers 10/Pack ZE-AOCWS10-KIT Air-O-Cell® Inner Wall Sampler Kit 10/Pack & A Plunger Rod
use, simply drill a 3/8"
by hand), connect the
and insert
into the
shelf life Pine pollen Skin cells Stachybotrys Dustmite Air flow into cassette Exit orifice Alternaria

Allergenco-D IAQ Air Sampling Cassettes

The Allergenco-D disposable IAQ air sampling cassette was developed for the sampling and collection of aeroallergens and bioaerosols for quantitative analysis of mold spores, pollen, skin fragments, insects, combustion particles, toners, environmental dusts, construction dusts, and other airborne particulates.

These cassettes employ a patented laminar flow venturi which provides higher readable collection efficiency than other IAQ cassettes as well as a more well defined impaction trace, helping to reduce analysis time.

Features

• Assembled under HEPA hoods

• Laminar flow venturi allows for the most uniform slit deposit in the industry

• Patented design

• Higher collection efficiency than other IAQ slit impactor cassettes

• Barcoded for easy tracking

• Inner wall sampling attachments available

• No luer adapters necessary - tubing fits directly onto cassette

• Compatible with all portable IAQ pumps designed to fit competitors cassettes

The Most Uniform Slit Sample Trace In The Industry!

Allergenco-D Posi-Track Full Slide Indoor Air Quality Impactor Cassettes

The Allergenco-D Posi-Track full slide cassette collects mold spores, pollen, skin cells, dust, combustion particles, etc. on a standard 1" x 3" microscope slide printed with a unique barcoded serial number (POSI-TRACK).

Features

• Superior collection efficiency - aerodynamic diameter cutoff = D50 = ~1.7 μm

• Patented laminar flow venturi design provides higher readable collection efficiency as well as a more well defined impaction trace

• Universal fittings allow the connection to a vacuum source with either a 1/2" to 1/4" converter or directly to a 1/4" I.D. tubing

• Generous area on the cassette label for field notes such as sample location, dates and time

• Barcoded serial number (POSI-TRACK) on the slide follows the sample from field sampling, through laboratory analysis and sample archive

• Designed to stack cassettes for easy storage and use

AIR SAMPLING AIR SAMPLING 25
Part Number Description Quantity EMS-120520 Allergenco-D Posi-Track Full Slide Indoor Air Quality Impactor Cassettes 24/Box *Limited shelf life
Part Number Description Quantity EMS-120515 Allergenco-D Air Sampling Cassettes 50/Box EMS-120518 Allergenco-D Inner Wall Samplers 10/Pack *Limited shelf life Need help choosing between the Zefon High Volume Diaphragm Area Sampling Pump and the Zefon® High Volume Rotary Vane Sampling Pump? Don’t worry ERE Inc.TM is here for you Please refer to page 11 for more information. 1-888-287-3732 In today’s world, our air is under constant threat from pollutants. Ensuring air quality is vital for our future. ERE Inc. offers advanced solutions to sample, monitor, filter, and treat contaminants. Let’s preserve the air we share, together!

Micro5 MicroCell IAQ Air Sampling Cassettes

Utilizing a 360o impaction chamber, the Micro5 was pioneered to evenly & quantitatively collect aeroallergens such as pollens, mold & fungal spores, fibers, danders, insect components and other air-borne contaminants.

Features

• Exceptionally uniform collection trace

• Virtually 100% accurate for the entire fungal spore range

• Designed to operate at a flow rate of 5 LPM to ensure optimal collection efficiency

*Limited shelf life

The Most Uniform Slit Sample Trace In

The Industry!

Micro5 Posi-Track Full Slide Indoor Air Quality Impactor Cassettes

The Micro5 Posi-Track full slide cassette collects mold spores, pollen, skin cells, dust, combustion particles, etc. on a standard 1" x 3" microscope slide printed with a unique barcoded serial number (POSI-TRACK).

*Limited shelf life

Features

• Superior collection efficiency - aerodynamic diameter cutoff = D50 = ~1.7 μm

• Patented laminar flow venturi design provides higher readable collection efficiency as well as a more well defined impaction trace

• Universal fittings allow the connection to a vacuum source with either a 1/2" to 1/4" converter or directly to a 1/4" I.D. tubing

• Generous area on the cassette label for field notes such as sample location, dates and time

• Minimizes handling and mounting of sample traces for microscopic particle counting

• Barcoded serial number (POSI-TRACK) on the slide follows the sample from field sampling, through laboratory analysis and sample archive

• Barcoded serial number (POSI-TRACK) allow for automated input of sample numbers into laboratory software (LIMS) and chain-of custody forms

• Deposition of particles/spores onto the adhesive is very uniform due to the design of the laminar flow venturi within the spore trap

• Designed to stack cassettes for easy storage and use

Zefon® Via-Cell® Bioaerosol Sampling Cassettes

The Zefon® Via-Cell® bioaerosol sampling cassette is designed to collect both viable and non-viable bioaerosols, maintain viability of the viable mold spores and prevent growth during transport to the laboratory. Simply connect it to any pump calibrated to 15 LPM and run your sample. The key to the Via-Cell® is that the media used for collection maintains viability of spores and allows several analysis options.

One Sample, Multiple Analysis Options

Culturable Sampling

The Zefon® Via-Cell® sampler is the perfect tool for collecting viable organisms and culturing them on agar plates. Simply dilute the media in sterile water and transfer to a culture plate.

PCR Analysis

The Zefon® Via-Cell® utilizes a water soluble collection media which is ideal for PCR and other chemical types of analysis. Once the sample is diluted in water, it can be transferred most anywhere.

Direct Microscopy

Samples collected using the Zefon® Via-Cell® sampler may be "pre-screened" using direct microscopy methods, which allows the analyst to decide if additional analysis techniques are needed, which may include culturing or standard direct microscopy analysis.

AIR SAMPLING 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM 26
Part Number Description Quantity EMS-120171 Micro5 Posi-Track Full Slide Indoor Air Quality Impactor Cassettes 24/Box
Part Number Description Quantity ZE-VIA010 Via-Cell® Air Sampling Cassettes 10/Box *Limited
Part Number Description Quantity EMS-120170 Micro5 Air Sampling Cassettes 50/Box EMS-120138-M5 Micro5 Inner Wall Samplers 10/Pack
shelf life

Zefon® Gemini® Twin Port Sorbent Tube Sampler

The Zefon® Gemini® Twin-Port Sorbent Tube Sampler can be used with the Zefon® Escort ELF®, or just about any other sampling pump able to pull a flow rate of 1.5 LPM at 25" of water backpressure. It offers increased flexibility and control in gathering samples through sorbent tubes.

If air is being sampled for two or more contaminants, the Gemini can draw samples at independent flow rates through tubes containing different sorbents. In situations where a single contaminant is being sampled, sampling on two tubes of the same type can be done simultaneously at different flow rates. This type of sampling protects against breakthrough which occurs when a tube’s sampling capacity is exceeded because the concentration of a contaminant is higher than anticipated. Duplicate sampling at the same flow rate can also be done to achieve better results.

Features

• Valved mechanism allows flow control down to 0.001 LPM

• Control the flow rate of each port independently

• Includes tube covers to fit both large and small tube sizes

Zefon® Sorbent Tubes

Includes

• Zefon® Gemini Twin-Port Sorbent Tube sampler

• Tube protectors

• Y-connectors

• Clips

• Carrying case

Zefon® Sorbent Tubes are high quality glass tubes that are packed with accurately weighed, high-purity sorbents. They are designed to adsorb vapors and gases passed over them when used with low flow sampling pumps and fit a variety of tube holders, including the Zefon® Gemini® Twin Port Sorbent Tube Sampler.

Many Zefon® sorbent tubes are divided into sections, with two absorbent sections being most common. The first section is twice the size of the back section and collects the compounds of interest. The second section is a backup section to determine if airborne contaminants breakthrough occurred on the front section.

Features

• Highest sorbent material purity for contamination-free samples

• Accurate sorbent weight for uniform testing results

• Uniform pressure drop to assure repeatable sampling results

• Designed to comply with all NIOSH specifications for tube dimensions, sorbent quality, particle size, divider composition and pore size

* Microlite sorbent is equivalent to Hydrar, Carulite, and the SKC Anasorb C300.

AIR SAMPLING AIR SAMPLING 27 Part Number Description ZE-497697 Zefon® Gemini® Twin Port Sampling Kit
Part Number Sorbent Size (O.D. x L) Sections Sorbent Tube Ends Separator* SKC Equivalent Quantity ZE-ZST-001 Coconut Charcoal 6 mm x 70 mm 2 100 mg / 50 mg GS F/F/W 226-01 50/Box ZE-ZST-001B Coconut Charcoal 6 mm x 70 mm 2 100 mg / 50 mg GS F/F/W 226-01B 1000/Box ZE-ZST-002 Coconut Charcoal 8 mm x 110 mm 2 400 mg / 200 mg GS F/F/W 226-09 50/Box ZE-ZST-002B Coconut Charcoal 8 mm x 110 mm 2 400 mg / 200 mg GS F/F/W 226-09B 1000/Box ZE-ZST-003 Coconut Charcoal 10 mm x 110 mm 2 800 mg / 200 mg GS F/W/W 226-16 50/Box ZE-ZST-020 Chromosorb 8 mm x 110 mm 2 100 mg / 50 mg GS W/W/W 226-107 50/Box ZE-ZST-040 Microlite* 6 mm X 70 mm 1 200 mg GS W/W 226-17-1A 50/Box ZE-ZST-050 Silica Gel 6 mm X 70 mm 2 150 mg / 75 mg GS F/W/W 226-10 50/Box ZE-ZST-051 Silica Gel 6 mm X 70 mm 2 100 mg / 50 mg GS F/W/W 226-51 50/Box ZE-ZST-054 Silica Gel 8 mm x 110 mm 2 520 mg / 360 mg GS W/W/W 226-10-04 50/Box ZE-ZST-058 Silica Gel 10 mm X 110 mm 2 1040 mg / 260 mg GS F/W/W 226-22 50/Box ZE-ZST-060 Silica Gel (specially cleaned) 7 mm X 110 mm 2 400 mg / 200 mg GS W/W/G/W 226-10-03 50/Box ZE-ZST-080 XAD-2 8 mm x 110 mm 2 100 mg / 50 mg GS W/W/W 226-30-04 50/Box ZE-ZST-090 XAD-7 6 mm X 110 mm 2 100 mg / 50 mg GS W/W/W 226-95 50/Box
Separator Codes W: Glass Wool G: Glass Fiber Filter F: Polyurethane Foam Tube Ends GS: Glass sealed GO: Glass open

Personal Pump Accessories

Cassette

Opener For 25 mm, 37 mm & Air-O-Cell® Cassettes ZE-ZA0049

Opener For 47 mm & Air-O-Cell® Cassettes

ZE-ZA0061 Universal Cassette/Cyclone Holder, Each

ZE-ZA0005 Plastic Luer Adapters, 10/Pack (Attaches Cassette to 1/4" I.D. Tubing)

ZE-459743 Metal Luer Adapters, 3/Pack (Attaches Cassette to 1/4" I.D. Tubing)

ZE-ZA0010 25 mm Conductive Filter Transport Case

Buck Low Flow Sorbent Tube Holders

Available both with and without flow adjustment. Use non-adjustable when using a sampling pump designed specifically for low flow sampling without adapters. Use adjustable flow to use with standard sampling pumps in constant pressure mode. Tube holder comes setup for 6 mm x 70 mm tubes. Additional size tube covers maybe purchased separately.

Sorbent Tube Accessories

Part Number Description

GIL-7015377P Tube Tip Breaker, 5/Pack

APB-109032 Single Tube Holder With Non-Adjustable Flow

APB-109030 Single Tube Holder With Adjustable Flow (5 - 800 cc/min)

APB-109033 Single Tube Holder With Adjustable Flow (5 - 100 cc/min)

APB-109022 6 mm O.D. x 70 mm L Tube Cover

APB-109024 8 mm O.D. x 110 mm L Tube Cover

APB-109026 10 mm O.D. x 150 mm L Tube Cover

APB-109028 10 mm O.D. x 220 mm L Tube Cover

AIR SAMPLING 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM 28 Part Number Description CY-8860-4335 3/8'' O.D. x 1/4'' I.D. Clearflex 60 Non-Phtalate
Tubing, 100 ft ZE-456226 3/8'' O.D. x 1/4'' I.D. x 36"
Sample Tubing
PVC
Long PVC Tubing With Tube Clip
ZE-456226 CY-8860-4335 ZE-ZA0046
APB-109030 GIL-7015377P Tube Covers 6 mm O.D. x 70 mm L 8 mm O.D. x 110 mm L 10 mm O.D. x 150 mm L 10 mm O.D. x 220mm L ZE-459743 ZE-ZA0010 ZE-ZA0005
ZE-ZA0061
Cassette
Cassette
Accessories Part Number Description ZE-ZA0046

Area Pump Replacement Parts

For Zefon® High Volume Diaphragm Area Sampling Pump

ZE-03113

ZE-03184 Rubber Foot For Diaphragm Pumps

ZE-03179 Muffler For Diaphragm Pump

For Zefon® High Volume Rotary Vane Sampling Pump Part

ZE-03113 1/8" Air Flow Regulator Valve

ZE-03200 1/4" Hose Barb

ZE-03201 Rubber Foot For ZE-ZHV00 Pump

ZE-AL-9800-52 Exhaust Filter For ZE-ZHV00 Pump

ZE-ZGHV01 Glass Muffler Jar For ZE-ZHV00 Pump

ZE-AA928 Felt Filters For ZE-ZHV00 Pump

Area Pump Accessories

AIR SAMPLING AIR SAMPLING 29
ZE-03113 ZE-03113 ZE-ZGHV01 ZE-03180 ZE-AA928 ZE-03200 ZE-03200 ZE-03184 ZE-03201 ZE-03179
Number Description
Part
1/8"
Air Flow Regulator Valve ZE-03180 1/8" To 1/4" Conversion Fitting
ZE-03200 1/4" Hose Barb
Number Description
Part Number Description EMS-200550 Premium Telescopic Sampling Tripod Stand CY-8860-4335 3/8'' O.D. x 1/4'' I.D. Clearflex 60 Non-Phtalate PVC Tubing, 100 ft ZE-ZA0005 Plastic Luer Adapter, 10/Pack (Attaches Cassette to 1/4" I.D. Tubing) ZE-459743 Metal Luer Adapter, 3/Pack (Attaches Cassette to 1/4" I.D. Tubing)
ZE-459743 ZE-ZA0005 EMS-200550 CY-8860-4335

Air Sampling Bag Selection Guide

Choosing The Best Film For Your Gas Sampling Bag Needs

Tedlar®

• Low gas permeation

• High tensile strength

• Max. operating temp: 400°F

• Unaffected by the chemical components of gases commonly sampled

ALTEF

• Developed specifically for gas sampling applications

• Chemically inert to most acids, aliphatic and aromatic organic compounds, chlorinated solvents, and alcohols

• Max. operating temp: 260°F

• Made of 0.003" thick film

Multi-layer Foil

FEP

• Ideal for collecting low molecular weight compounds such as: CH4, H2S, CO, and CO2

• Foil layers provide very low permeability and complete moisture barrier

• Max. operating temp: 190°F

• Opaqueness protects samples from ultraviolet light

• One of the most chemically inert materials available for making gas sampling bags

• Max operating temperature: 400°F

• Virtually transparent

PFA

TFM

• Highest purity, most chemically inert film available for making gas sampling bags

• Wide temp range -420°F to 500°F

• High purity, flexible, low permeation versus FEP and PFA

• Translucent

• Wide temperature range; from –328°F to 500°F

• Less permeable than FEP, PFA and TFM

• Bags resist puncture in the field

• Less expensive than FEP, PFA, TFM film

• Suitable for sampling most VOC's and many sulfur compounds

• Low VOC background

• Longer sample storage times than most other bag materials

• Does not exhibit background levels of DMAC or phenol

• Lower permeability than Tedlar® to CO2, N2, and CH

4

• Superior resistance to solvents

• The only bag material that adequately holds H2S for long periods

• Ideal for collecting low molecular weight compounds

• Sample stability up to 5 days for most compounds

• Very low permeability to O2 and CO2

• Good VOC stability

• Less expensive than Tedlar® and ALTEF

• Works well in extreme temperatures from -400°F to 400°F

• Heavier gauge film is resistant to most severe corrosives as well as tolerates applications involving rough handling or difficult service conditions

• Less expensive than PFA

• Not affected by the most corrosive chemicals, such as HF, Nitric, HCL and Sulfuric Acids

• Temps from –400°F to 500°F

• Not affected by the most corrosive chemicals, such as HF, Nitric, HCL and Sulfuric Acids

• Sample stability for 4 to 5 days for most compounds

• Withstands temperatures from –400°F to 500°F

• Exhibits background levels of DMAC and phenol

• High permeation rate for CO2

• Relatively high permeation rate for O2

• More permeable to most compounds than Tedlar®

• Not suitable for sampling ketones and esters in high concentrations (>30%)

• Less resistance to UV light than Tedlar®

• Many sulfur compounds must be analyzed within 24 hours.

• More expensive than Tedlar®

• Not recommended for collecting low ppm to high ppb VOC's due to background levels from bag materials

• Recommend analyzing within 48 hours after collection for CH4, H2S, CO, and CO2

• Poor long term storage stability for most VOC's and sulfur compounds

• Much more permeable and more expensive than Tedlar®, ALTEF, and MultiLayer Foil bags

• Lower tensile strength than Tedlar®

• Poor long term storage stability for most VOC's and sulfur compounds

• The most expensive film option for gas sampling bags

• Much more permeable than Tedlar®

• Expensive

• Tears easily

• Low tensile strength

• More permeable than Tedlar®, ALTEF, and Multi-Layer foil bags

AIR SAMPLING 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM 30
Properties Advantages Limitations

Valves and Fittings Features

Polypropylene Screw Cap Combo Valve With Replaceable Septum

Polypropylene Locking® Combo Valve With Septum

Stainless Steel TCLP Fitting With Replaceable Septum

Swagelok® Type Stainless Steel Fitting For Tubing Or Septum

Nickel Plated Halkey® Roberts Barbed On/Off Valve

Plastic Jaco® Fitting For Tubing Or Septum

PFA Fitting For Tubing Or Septum

• On/Off valve function with replaceable septum in a single unit

• Made of Inert polypropylene

• Quick turning screw cap to open and close valve

• Visual confirmation that valve is open or closed

• On/Off valve function with septum in a single unit

• Made of Inert polypropylene

• Push/Pull (On/Off) valve stem

• Quick Locking function, in closed position Fluoropolymer faced septum, with Ultra-low bleed silicone

• Stainless steel body construction with aluminum cap

• Designed for use with Zero Headspace Extractors

• Replaceable fluoropolymer faced septum

• Stainless steel construction

• Option of cap for tubing or septum

• Replaceable fluoropolymer faced septum with large area

• Barbed stem for attaching tubing

• Leak resistant seal in closed position

• Compression ferrule secures tubing onto fitting

• Polypropylene molded construction

• Option of cap for tubing, or cap with septum

• Replaceable fluoropolymer faced septum with large area

• PFA fluoropolymer construction

• Option of cap for tubing, or cap with septum

• Compression ferrule secures tubing onto fitting

• Replaceable fluoropolymer faced septum with large area

AIR SAMPLING AIR SAMPLING 31
Part Number Capacity Bag Size Stem Size Quantity JIP-GSTP00-0606NSG1B 0.6 L 6" x 6" 3/16" O.D. 10/Pack JIP-GSTP010707NSG1B 1 L 7" x 7" 3/16" O.D. 10/Pack JIP-GSTP00-0610NSG1B 1.2 L 6" x 6" 3/16" O.D. 10/Pack JIP-GSTP02-0909NSG1B 2 L 9" x 9" 3/16" O.D. 10/Pack JIP-GSTP03-1010NSG1B 3 L 10" x 10" 3/16" O.D. 10/Pack JIP-GSTP05-1212NSG1B 5 L 12" x 12" 3/16" O.D. 10/Pack JIP-GSTP07-1215NSG1B 7 L 12" x 15" 3/16" O.D. 10/Pack JIP-GSTP08-1217NSG1B 8 L 12" x 17" 3/16" O.D. 10/Pack JIP-GSTP09-1218NSG1B 9.5 L 12" x 18" 3/16" O.D. 10/Pack JIP-GSTP10-1219NSG1B 10 L 12" x 19" 3/16" O.D. 10/Pack Part Number Capacity Bag Size Stem Size Quantity JIP-GSTP12-1221NSG1B 12 L 12" x 21" 3/16" O.D. 5/Pack JIP-GSTP16-1818NSG1B 16 L 18" x 18" 3/16" O.D. 5/Pack JIP-GSTP25-1824NSG1B 25 L 18" x 24" 3/16" O.D. 5/Pack JIP-GSTP40-2424NSG1B 40 L 24" x 24" 3/16" O.D. 5/Pack JIP-GSTP56-2430NSG1B 56 L 24" x 30" 3/16" O.D. 3/Pack JIP-GSTP73-2436NSG1B 73 L 24" x 36" 3/16" O.D. 3/Pack JIP-GSTP80-3030NSG1B 80 L 30" x 30" 3/16" O.D. 3/Pack JIP-GSTP1003036NSG1B 100 L 30" x 36" 3/16" O.D. 3/Pack JIP-SEP5007-NSCV-10 Replacement Septa 10/Pack Tedlar® Gas Sampling Bag With Screw Cap Combo Valve With Replaceable Septum Valves And Fittings For Gas Sampling Bags Polypropylene Locking Combo Vakve with Septum Polypropylene Screw Cap Combo Valve with Replaceable Septum Stainless Steel Push/Pull Valve Stainless Steel TCLP Fitting with Replaceable Septum PFA Fitting Tubing or Septum PTFE On/Off Valve with Stopcock Nickel Plated HR Barbed On/Off Valve Plastic Jaco Plating for Tubing or Septum Swagelok Type Stainless Steel Fitting for Tubing or Septum

Direct Read Passive Monitoring System

ChromAir® System Chemical Detection Badges

In some settings, monitoring the amount of exposure is the key to safe working conditions. ChromAir® is designed to detect exposure dose levels to specific toxic chemicals. The ChromAir® chemical exposure monitoring badge offers six exposure levels, with most indicating from one-tenth to two times the Permissible Exposure Limit (PEL) Time Weighted Average (TWA) for an eight-hour work period. To determine the average concentration, users can locate the highest cell with a color change and divide the corresponding dose level (parts per million times hour) by the sampling time in hours.

For higher resolution and accuracy, the ChromAir® badges can-be-used with the ChromAir® color comparators. The color scales on the color comparator identically match the colors formed on the ChromAir® badge.

Features

• Easy to read color change

• Highly sensitive and selective

• Exposure data read directly from badge

• Measure TWA exposure

• Immediate response for short-term exposure measurements

• Patented design minimizes effects of humidity and velocity

• Light-weight and cost effective for personnel and area monitoring

How Colorimetric Detection Chemistry Works

Color originates from the complex and fascinating interaction of visible light with chromophores, or groups of atoms in molecules which are capable of absorbing certain wavelengths of visible light. Due to this absorption phenomenon, these substances are perceived as having color. The hue and depth of the perceived color are related to the specific wavelengths absorbed and the intrinsic absorption efficiency of the molecule, respectively.

The distribution of electron density in a molecule is responsible for the absorption characteristics of that molecule. The alteration of electron density distribution in a molecule through reaction with another chemical species forms the basis for colorimetric chemical detection.

AIR MONITORING 32 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM
Part Number Description MT-401966-10 Strap Clips, 10/Pack MT-401966-100 Strap Clips, 100/Pack MT-401966-500 Strap Clips, 500/Pack Accessories Part Number Chemical Range Interferences Quantity MT-380003-10 Ammonia 4 - 300 ppm/hr RNH2 10/Pack MT-380008-10 Carbon Monoxide 10 - 525 ppm/hr Alkenes, H2, H2S 10/Pack MT-380004-10 Chlorine 0.4 - >13 ppm/hr Br2, HCl, I2 10/Pack MT-380007-10 Formaldehyde 0.3 - 12 ppm/hr Acrolein 10/Pack MT-380017-10 Glutaraldehyde 0.04 - 0.95 ppm/hr None Known 10/Pack MT-380018-10 Mercury 0.125 - 1.6 mg/m3/hr Strong Oxidizers 10/Pack MT-380010-10 Ozone 0.08 - 1.6 ppm/hr H2O2, NO2 3 10/Pack ChromAir® Badges *1ChromAir® glutaraldehyde STEL badges are for 15 minutes of monitoring only. The scale on the badge is in ppm *2ChromAir® mercury badge and color comparator scale is in mg/m3 hr *3Coefficient must be applied to scale printed on badge *4ChromAir® ozone badges are ten times more sensitive to ozone than nitrogen dioxide Inf Z ne

SafeAir® System Chemical Detection Badges

When there is a threat of chemical hazard, immediate detection is paramount. The SafeAir® System offers immediate visual confirmation of a specific chemical hazard. SafeAir® chemical detection badges are available for many different toxic industrial chemicals. The highly sensitive and selective sensor in the SafeAir® badge is designed to show a homogeneous and stable color change, which appears as an exclamation point when a particular chemical is present.

For higher resolution and wider range, the SafeAir® badges can-be-used with the SafeAir® color comparator. Slide the SafeAir® badge with the exclamation point facing up into the color comparator and turn the wheel until the colors match. Read the exposure dose in the exposure dose window.

Features

• Easy to use

• Highly sensitive and selective

• Ideal for daily employee screening or leak detection

• Measure TWA exposure

• Immediate, on-site results

• No calibration or laboratory analysis needed

33 AIR MONITORING AIR MONITORING
SafeAir® System Badges Part Number Chemical Threshold Level Interferences Comparator Part Number Quantity MT-382010-50 Ammonia 4 ppm/hr Primary Aliphatic Amines - 50/Pack MT-382001-50 Aromatic Isocyanates (TDI & MDI) TDI: 5 ppb/hr MDI: 3.5 ppb/hr Other Aromatic Isocyanates TDI: MT-383005 50/Pack MT-382009-50 Chlorine 0.18 ppm/hr Br2, HCl, I2 MT-383010 50/Pack MT-382003-50 Chlorine/Chlorine Dioxide Cl2: 0.18 ppm/hr ClO2 : 0.2 ppm/hr Cl2: Br2, HCl, I2 ClO2: NO2, High Concentration O3 - 50/Pack MT-382011-50 Formaldehyde 0.2 ppm/hr Acrolein - 50/Pack MT-382002-50 Hydrazine 8 ppb/hr MMH, Aromatic Amines MT-383001 50/Pack MT-382020-50 Hydrazine Dual-Level Front: 8 ppb/hr Back: 4 ppb/hr MMH, Aromatic Amines - 50/Pack MT-382015-50 Hydrogen Sulfide 2 ppm/hr None Known - 50/Pack MT-382005-50 Mercury Front: 0.25 mg/m3/hr Back: 0.08 mg/m3/hr Strong Oxidizers - 50/Pack MT-382004-50 Ozone 0.05 ppm/hr H2O2, Above 1 ppm NO2 - 50/Pack MT-382036-50 Phosgene 8.3 ppb/hr COBr2, CNCl, ClCO2 MT-383016 50/Pack MT-382065-100 Phosgene Dura 20 ppb/hr COBr2, CNCl, ClCO2 MT-383022 100/Pack MT-382060-100 Phosgene Medi 166.7 ppb/hr COBr2, CNCl, ClCO2 MT-383020 100/Pack MT-382014-50 Sulfur Dioxide 0.2 ppm/hr None Known - 50/Pack Part Number Description Range Quantity MT-383005 Color Comparator For TDI SafeAir® System Badges 5 - 140 ppb/hr Each MT-383010 Color Comparator For Chlorine SafeAir® System Badges 0.03 - 3 ppm/hr Each MT-383001 Color Comparator For Hydrazine SafeAir® System Badges 4.5 - 300 ppb/hr Each MT-383016 Color Comparator For Phosgene SafeAir® System Badges 0.5 - 450 ppm/min Each MT-383022 Color Comparator For Phosgene Dura SafeAir® System Badges 1.2 - 450 ppm/min Each MT-383020 Color Comparator For Phosgene Medi SafeAir® System Badges 10 - 450 ppm/min Each Part Number Description MT-401966-10 Strap Clips, 10/Pack MT-401966-100 Strap Clips, 100/Pack MT-401966-500 Strap Clips, 500/Pack MT-401967-500 Adhesive Discs, 500/Pack Accessories
Comparators
Color

The Easiest To Use Colorimetric Gas Detector Tube Pump!

AP-20S Gas Detection Pump

The Sensidyne AP-20S gas detection pump kit when used in conjunction with Sensidyne detector tubes is a portable gas detection system that is lightweight, rugged, and capable of on-the-spot detection of numerous gases and vapors .

Features

• First detector tube pump with an antibacterial blue grip

• Sample flow indicator

• Detector tube tip cutter and storage

• Two-stage locking pump mechanism on the pump handle that allows sampling of either 50 ml or 100 ml sample volumes

• Pump has a positive start and stop for each stroke

• Withstands harsh environments and comes with a lifetime warrant

Includes

• AP-20S gas detection pump

• Two rubber tube-connectors

• Lubricant

• Tube handbook

• Manual

• Transport cage

GIL-830-1003-01

*Sensidyne pump and Sensidyne colorimetric gas detector tubes are not interchangeable with other manufacturers’ pumps and detector tubes

Sensidyne Colorimetric Gas Detector Tubes

The Sensidyne colorimetric gas detector tubes safely allow users to perform field screening and tests for the presence of hazardous and toxic gases, and chemical vapors at a very low cost-per-sample. Gas detector tubes from Sensidyne are precision tubes offering a higher level of accuracy and repeatability for applications where results matter.

Applications

• Metal fabrication

• Degreasing

• Welding

• Sewage & waste water treatment plants

• Aerospace manufacturing

• Hazardous water handling

• Railroad & tank cars

• Parking garages

• Laboratory

• Pharmaceutical & medical manufacturing

• Food manufacturing

AIR MONITORING 34 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM
Part Number Description
AP-20S Gas Detection Pump Kit GIL-830-1001-01 5 m Extension Hose For AP-20S Pump GIL-830-1002-01 10 m Extension Hose For AP-20S Pump
GIL-830-0001-01
2 m Telescoping Extension
Probe
Sampling Flow Indication
Tip Cutter

Features

• Detector tubes for hundreds of gases

• Easy to use & provides a low-cost method of routine or spot sampling for gases & vapors

• Most tubes use a single pump stroke

• Plastic coating on the glass makes them shatterproof

• Uses smaller particles, which make the color change brighter and easier to see

• Perfect when sampling for a known target gas

• When the target gas or substance is unknown, the specialty HazMat kits provide an excellent answer for quick identification & measurement

Acetaldehyde Chlorobenzene Ethyl Alcohol Isopropyl & Ethyl Acetate Nitric Acid Vapor Silane

Acetic Acid Chloroform Ethyl Benzene Isopropyl Alcohol Nitric Oxide & NO2 Styrene

Acetone Chloropicrin Ethyl Mercaptan Ethylene MEK & Dioxane Nitrogen Dioxide Sulfide Ion In Water

Acetylene Chloroprene Ethylene Dibromide Mercaptans O-Dichlorobenzene Sulfur Dioxide

Acrolein Copper Ion In Water Ethylene Glycol Mercury Vapor Oil Mist Compressed Breathing Air Tube Sulfuric Acid

Acrylonitrile Cyclohexane Ethylene Oxide Methyl Alcohol Organic compounds Tetrachloroethylene

Ammonia Cyclohexanol Formaldehyde Methyl Bromide Organic gases Oxygen & Carbon Dioxide Tetraethoxysilane

Aniline Cyclohexanone Furfuryl Alcohol Methyl Chloroform Oxygen Tetrahydrofuran

Arsine Diborane Gasoline Methyl Cyclohexane Oxygen Compressed Breathing Air Tube Toluene

Benzene Dichloroethane General Hydrocarbons Methyl Cyclohexanol Ozone Trichloroethylene

Bromine 1,2-Dichloroethylene Hydrazine Methyl Ethyl Ketone P-Dichlorobenzene Triethylamine

Butadiene 2,2-Dichloroethyl Ether Hydrocarbons Methyl Iodide Pentyl Acetate Vinyl Acetate

2-Butanol Dichloromethane Hydrogen Methyl Isobutyl Ketone Ozone Vinyl Chloride

Butyl Acetate 1,3-Dichloropropane Hydrogen Chloride Methyl Mercaptan Phenol & Cresol Water Vapor

Carbon Dioxide Diethyl & Trimethyl Amine Hydrogen Cyanide Methyl Methacrylate & Allyl Alcoho Phosgene Water Vapor Compressed Breathing Air Tube

Carbon Disulfide Diethyl Ether Hydrogen Fluoride Methyl Styrene Phosphine & Arsine Water Vapor

Carbon Monoxide Dimethyl & Ethyl & Methyl Amine Hydrogen Peroxide Monoethanol Amine Phosphine Xylene

Carbon Tetrachloride Dimethyl Ether Hydrogen Selenide N,N-Dimethyl Formamide Propane

Carbonyl Sulfide Epichlorohydrin Hydrogen Sulfide N,N-Dimethylacetamide Propyl Acetate

Chloride Ion In Water Ethyl & Butyl & Isobutyl Acrylate Hydrogen Sulfide & Mercaptans N-Butane Propylene

Chlorine Ethyl & Methyl Cellosolve Isobutyl Acetate N-Hexane Propylene Oxide

Chlorine Dioxide Ethyl Acetate Isobutyl Alcohol Nickel Carbonyl Salinity In Water

*Sensidyne pump and Sensidyne colorimetric gas detector tubes are not interchangeable with other manufacturers’ pumps and detector tubes

ADVANTAGES

• Most of our tubes use a single pump stroke

• Pump has a positive start and stop for each stroke

• Uses smaller particles, which make the color change brighter and easier to see

• Plastic coating on the glass, makes them shatterproof

• Pump has an anti-bacterial grip, making it safer to use in medical settings

• Competitive pricing

• Extensive list of gases

35 AIR MONITORING AIR MONITORING Extensive List Of Gases & Ranges CALL US TODAY! 1-888-287-3732
Inf Z ne

Dräger accuro® Gas Detection Pump

The Dräger accuro® pump is a manually operated bellows pump that draws a calibrated 100 ml sample through the Short-Term Dräger-Tubes® for the sampling of toxic gases and vapors. It is independent of external energy sources therefore, there are no usage restrictions in areas of explosion hazard. An internal scissor mechanism built into the Dräger accuro® pump bellows provides parallel compression of the pump and an automatic stroke counter, which is integrated in the pump head, records the number of strokes.

Features

• For short-term measurements with a small numbers of strokes

• Hand-operated bellows pump with one-handed operation

• Built-in automatic stroke counter

• End-of-stroke indicator

• Number of Strokes: 1 - 50 strokes and higher

• Stroke volume: 100 ml (±5%)

DR-8317186 Soft-Side accuro® Pump Kit

DR-4056443 Hard-Side accuro® Pump Kit

• Tube Opener

• Allen Wrench

• accuro® Pump

• Tube Opener

• Allen Wrench

• accuro® Pump

• Tube Opener

• Allen Wrench

• Spare Parts Kit

• NylonTransport Case

• Spare Parts Kit

• (10) Rubber Caps

• Pelican® Plastic Transport Case

*3

DR-6400561 1 m Extension Hose For Dräger accuro® & Dräger X-act® 5000 Pumps

• 1 m Extension Hose

• Adapter For Simultaneous Test Sets

X-act® 5000 Automatic Tube Pump

The Dräger X-act® 5000 all-in-one, automatic tube pump is used in conjunction with Short-Term Dräger-Tubes®, simultest sets, and sorbent tubes for the sampling of toxic gases and vapors in the workplace. The bar code reader transfers all relevant measurement parameters using the bar code on the box of Dräger-Tubes.

*3 m, 10 m, 15 m & 30 m extension hose also available

Features

• For short-term measurements with higher numbers of strokes and sample taking with sampling tubes and systems

• Menu-driven automatic pump

• Built-in barcode reader with Class 3R

• Number of strokes: adjustable 1 - 199 strokes

• Stroke volume: 100 ml (±5%)

• (6) AA alkaline batteries or rechargeable NiMH battery pack

• Protection class: Ex-approved, IP 64

• 1 m Extension Hose

• Adapter For Simultaneous Test Sets

*Dräger pumps and Short-Term Dräger-Tubes® are not interchangeable with other manufacturers’ pumps and detector tubes

AIR MONITORING 36 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM
Part Number Description Includes
accuro®
DR-6400000
Pump
accuro® Pump
m & 10 m extension hose also available
*Dräger pumps and Short-Term Dräger-Tubes® are not interchangeable with other manufacturers’ pumps and detector tubes
Part Number Description Includes DR-4523500 Dräger X-act® 5000 Pump • X-act® 5000 Pump
Shoulder Strap DR-4523617 Dräger X-act® 5000 Pump Kit
X-act
® 5000 Pump
• Shoulder Strap • Rechargeable NiMH Battery • 100-240 VAC Charger
DR-6400561 1 m Extension Hose For Dräger accuro® & Dräger X-act® 5000 Pumps

Short-Term Dräger-Tubes®

Short-Term Dräger-Tubes® are an easy to use and cost effective way to measure toxic gases and vapors in the workplace. More than 200 different Short-Term Dräger-Tubes® are available to accurately make spot measurements for over 500 gases and vapors. The Short-Term Dräger-Tubes® are used in conjunction with either a manual or an automatic sampling pump using individual Short-Term Dräger-Tubes® or special 5 tube sets for simultaneous measurement.

Applications

• Determining and measuring concentration peaks

• Measuring personal exposure in the inhalation area

• Detecting leaks in pipelines, gas installations, etc.

• Air analysis in sewers, shafts and confined spaces

• Evaluation of concentration fluctuations in the workplace

• Measurement of contaminants in the worker’s breathing zone

• The investigation of confined spaces (ex: grain silos, chemical tanks, sewers) prior to entry

• Check for gas leaks in process pipelines

Features

• More than 200 Short-Term Dräger-Tubes® are available to measure spot concentrations of specific gases

• Designed for on-the-spot measurements at a particular location over a relatively short time period

• Perfect when sampling for a known target gas

• Measurements in the range of the occupational exposure limits

• Measurements in the area of emission concentrations

• Measurements may last from 10 seconds to 15 minutes or so depending on the particular Short-Term Dräger-Tubes® and sampling pump

Acid/Nitric Acid Olefins (Propylene, Butylene) Toluene

n-Butanol Dimethyl Sulfide Hydrogen Organic Arsenic Compounds & Arsine Toluene Diisocyanate

Carbon Dioxide Epichlorohydrin Hydrogen Fluoride Organic Basic Nitrogen Compounds Trichloroethane

Carbon Disulfide Ethanol Hydrogen Peroxide Oxygen Trichloroethylene

Carbon Monoxide Ethyl Acetate Hydrogen Sulfide + Sulfur Dioxide Ozone Triethylamine

Carbon Pretube Ethyl Benzene Hydrogen Sulfide Pentane Halogenated Hydrocarbons

Carbon Tetrachloride Ethyl Glycol Acetate Iodine Perchloroethylene Vinyl Chloride

Chlorine Ethylene Mercaptan Petroleum Hydrocarbons Water Vapor

Chlorine Dioxide Ethylene Glycol Mercury Phenol Xylene

Chlorobenzene Ethylene Oxide Methanol Phosgene

Chloroform Fluorine Methyl Acrylate Phosphine

37 AIR MONITORING AIR MONITORING
*Dräger pumps and Short-Term Dräger-Tubes® are not interchangeable with other manufacturers’ pumps and detector tubes. Extensive List Of Gases & Ranges CALL US TODAY! 1-888-287-3732 Acetaldehyde Chloroformates Formaldehyde Methyl Bromide Phosphoric Acid Esters Acetic Acid Chloropicrin Formaldehyde Methylene Chloride Polytest Acetone Chloroprene Formaldehyde Activation Tube Monostyrene i-Propanol Acid Test Qualitative Chromic Acid Formic Acid Natural Gas Test Pyridine Acrylonitrile Cyanide Halogenated Hydrocarbons Nickel Tetracarbonyl Smoke Tubes Air Current (Smoke Tubes) Cyanogen Chloride Hexane Nitric Acid Sulfur Dioxide Amine Test Qualitative Cyclohexan Hydrazine Nitrogen Dioxide Sulfuric Acid Ammonia Diesel Fuel Halogenated Hydrocarbons Nitrous Gases Sulfuryl Fluoride Aniline Diethyl Ether Hydrocarbons Oil Tetrahydrothiophene Arsine Dimethyl Formamide Hydrochloric Acid Oil Mist Thioether Benzene Dimethyl Sulfate Hydrochloric
Environmental Remediation Equipment Inc.

Need Help Choosing A Gas Detector?

Answer the following questions to help narrow it down.

1. Do you require a portable or fixed gas detector?

2. Do you require a single gas or multi-gas detector?

3. What gas or gases do you need to measure?

4. Do you require an instrument without an internal pump (passive monitoring) or with an internal pump (active monitoring)?

5. Do you require an instrument with or without datalogging?

Contact us and we will help you pick the right gas detector for your project

Still stuck? 1-888-287-3732

5 Versions Available CO, H2S, O2, CO/O2 & H2 Compensated CO

GasWatch 3 Single Gas Personal Monitor

The GasWatch 3 is the world’s smallest and lightest single gas and dual gas monitor designed to detect CO, H2S, O2, CO/O2 & H2 Compensated CO. Its compact form provides great comfort and flexibility in how you choose to wear it. It can be worn on your wrist as a watch, or clipped into your breathing zone on your lapel, hard hat or other safety equipment with the 360º rotation alligator clip.

Applications

• Refineries

• Petrochemical facilities

• Sewage treatment plants

• Fire departments

• Chemical plants

• Tunnels

• Mines

• Hazardous waste sites

Features

• Light and compact "watch type" design

• Easily worn clipped in your "breathing zone"

• Available with watch band or alligator clip

• Automatic backlight during alarm

• Sturdy IP-66/68 rated design

• Water, dust and radio frequency (RF) resistant

• Non-compliance indicator

Kit Includes

• GasWatch 3 monitor

• Watch band or alligator clip

• Spring pins (used to mount accessories on to the rear face)

• CR2450 coin-type lithium-ion battery

AIR MONITORING 38 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM

• NLB-417

• RK-81-1194

• NLB-H101650PN

• NLBH1049200PA

• NLB-417

• NLB-H101650PN

• NLB-H1066

• NLB-417

• RK-06-1248RK-03

• NLB-500D

• RK-06-1248RK-03

• NLB-500D

• RK-81-1194

• RK-06-1248RK-03

• NLB-500D

• RK-81-1194

• RK-06-1248RK-03

• NLB-500D RK-72-0012-01

• NLB-H1066

• NLB-417

• RK-81-1194

• RK-06-1248RK-03

• NLB-500D

*GasWatch 3 with alligator clip models also available

39 AIR MONITORING AIR MONITORING Model Name GW-3 (HS) GW-3 (CO) GW-3 (C-) GW-3 (CX) GX-3 (O2) Gas Detected Hydrogen Sulfide Carbon Monoxide H2 Compensated CO Carbon Monoxide Oxygen Oxygen Detection Principal Electrochemical Dual Electrochemical Galvanic Cell Detection Range (Increments) 0 ~ 30 ppm (0.1 ppm) 30 ~ 100 ppm (1 ppm) 0 ~ 300 ppm (1 ppm) 0 ~ 25.0% Vol. (0.1% Vol.) Gas Sampling Diffusion Power Source CR2450 coin-type lithium ion battery Operating Temp. & Humidity -20°C to +50°C (no sudden changes) (Approx. 15-minute temporary use environment: -20°C to +60°C)
changes]
90% RH
condensation)
environment:
-20°C to +50°C
[no sudden
10 to
(no
(Approx. 15-minute temporary use
0 to 95% RH) [no condensation]
(no sudden changes)
90%
Safety Rating ATEX, IECEx, CSA Part Number Description Model Detection Range Calibration Equipment RK-73-0022-01 GasWatch 3 For H2S With Wrist Band GW-3 (HS) 0 ~ 30 ppm 30 ~ 100 ppm • NLB-F105325PN
NLB-517
RK-81-1194
10 to
RH (no condensation)
RK-73-0023-01 GasWatch 3 For CO With Wrist Band GW-3 (CO) 0 ~ 300 ppm
NLB-H101650PN
RK-73-0025-01 GasWatch 3 For CO With H2 Compensated Sensor & Wrist Band GW-3 (C-) 0 ~ 300 ppm
RK-73-0026-01 GasWatch 3 For CO/O2 Combination With Wrist Band GW-3 (CX) (Dual
CO: 0 ~ 300 ppm O2: 0 ~ 25.0% Vol.
Sensor)
GasWatch
Band GX-3 (O2) 0 ~ 25.0% Vol.
3 For O2 With Wrist
Part Number Description NLB-F105325PN Calibration Gas 25 PPM H2S In N2, 34 Liter Steel Cylinder With CGA 600 NLB-H101650PN Calibration Gas 50 PPM CO In N2, 34 Liter Steel Cylinder With CGA 600 NLB-H1049200PA Calibration Gas 200 PPM H2 in Air, 34 Liter Steel Cylinder With CGA 600 NLB-H1066 Calibration Gas 100% N2, 34 Liter Steel Cylinder With CGA 600 NLB-417 0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA 600 NLB-517 0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA C-10 RK-81-1194 Calibration Adapter For GasWatch 3 RK-06-1248RK-03 3/16" I.D. x 5/16" O.D. Polyurethane Calibration Tubing, 3 ft NLB-500D Case For 17 / 29 / 34 Liter Steel Cylinders, Holds 2 Cylinders Accessories & Calibration Equipment H2S CO CO (-H2) CO/O2 O2 AUTHORIZED RKI SERVICE CENTER

4 Versions Available LEL, O2, H2S & CO

03 Series Single Gas Clip-On Personal Monitor

The 03 Series single gas monitors are designed for LEL, O2, H2S or CO detection. Individuals need personal protection in hazardous areas at all times without adding extra bulky equipment and the 03 Series can provide that kind of protection at an affordable price.

Applications

• Hazardous material

• Mining

• Tunnels

• Refineries / petrochemical

• Water / waste water treatment

• Pharmaceutical manufacturing

• Utilities

• Chemical plants

Kit Includes

• GP-03, OX-03, HS-03 or CO-03 monitor

• Alligator clip

• Screwdriver

• (2) AAA alkaline batteries

• Rubber boot

• Quick reference card

• Small padded case

• Fire services

Features

• Data log 5 to 30 hours with adjustable intervals

• Peak hold, STEL and TWA

• Audible, vibration and visual alarms

• Automatic backlight

• Low battery alarm

• Impact, dust and water resistant (IP-67)

• Replaceable rubber boot

trends, gas readings, calibration & bump test history, instrument information and settings

Power Source Alkaline dry cell (2-AAA size) Alkaline dry cell (2-AAA size) Ni-MH battery

Operating

20°C ~ 50°C (-4°F ~ 122°F); Humidity below 90% RH (non-condensing)

Safety Rating ATEX/IECEx approved, CSA classified, "C/US", as intrinsically safe, Class I, Division 1, Groups A, B, C, D

AIR MONITORING 40 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM
Model CO-03 HS-03 OX-03 GP-03 Gas Detected Carbon Monoxide (CO) Hydrogen Sulfide (H2S) Oxygen (O2) Combustible Gas Detection Principal Electrochemical Galvanic Cell Catalytic Combustion Detection Range (Increments) 0 - 500 ppm (1 ppm) 0 - 100 ppm (0.5 ppm) 0 - 40% Vol. (0.1% Vol.) 0 - 100% LEL (1% LEL) Gas Sampling Diffusion Accuracy (Whichever Is Greater) ± 5% of reading or ± 5 ppm (CO) ± 5% of reading or ± 2 ppm (H2S) ± 0.5% Vol. (O2) ± 5% of reading or ± 2% (LEL) Data Logging 10 second intervals = 5 hours, 5 minute intervals = 150 hours,
alarms,
10 minute intervals = 300 hours Instrument records
alarm
Humidity
Temp. &

SDM-03 Single Point Calibration Station

41 AIR MONITORING AIR MONITORING Part Number Description Model Detection Range Calibration Equipment RK-73-0060-50 03 Series For CO CO-03 0 - 500 ppm
NLB-H101650PA
NLB-417
RK-81-1146
RK-06-1248RK-03
NLB-500D RK-73-0062-50 03 Series For H2S HS-03 0 - 100 ppm
NLB-F105325PN
NLB-517
RK-81-1146
RK-06-1248RK-03
RK-72-0010-50 03 Series For O2 OX-03 0 - 40% Vol.
NLB-500D
NLB-H1066
NLB-417
RK-81-1146
RK-06-1248RK-03
NLB-500D RK-72-0037-50 03 Series For LEL GP-03 0 - 100% LEL
NLB-H197150LA
NLB-417
RK-81-1146
RK-06-1248RK-03
NLB-500D Part Number Description RK-81-SDM03-01 SDM-03 Single Point Calibration Station For 03 Series With AC Adaptor, Flash Drive, USB Cable & Tubing NLB-H101650PA Calibration Gas 50 PPM CO In Air, 34 Liter Steel Cylinder With CGA 600 NLB-F105325PN Calibration Gas 25 PPM H2S In N2, 34 Liter Steel Cylinder With CGA 600 NLB-H1066 Calibration Gas 100% N2, 34 Liter Steel Cylinder With CGA 600 NLB-H120815LA Calibration Gas 15% LEL Hexane In Air, 34 Liter Steel Cylinder With CGA 600 NLB-H197150LA Calibration Gas 2.5% CH4 (50% LEL) In Air, 34 Liter Steel Cylinder With CGA 600 NLB-H104950LA Calibration Gas 2.00% H2 (50% LEL) In Air, 34 Liter Steel Cylinder With CGA 600 NLB-H196950LA Calibration Gas 50% LEL Isobutane In Air, 34 Liter Steel Cylinder With CGA 600 NLB-417 0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA 600 NLB-517 0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA C-10 RK-81-1146 Calibration Adapter For 03 Series RK-06-1248RK-03 3/16" I.D. x 5/16" O.D. Polyurethane Calibration Tubing, 3 ft NLB-500D Case For 17 / 29 / 34 Liter Steel Cylinders, Holds 2 Cylinders
& Calibration Equipment
Accessories

Dräger Pac® Series - Fast & Robust Single Gas Detection Devices

The Dräger Pac® series is available with a wide variety of sensors. They provide fast and reliable gas detection to ensure life safety in your facility.

Features

• Easy to use and are manufactured using the latest technology

• Devices are very robust with a 360° alarm signal, clear color coding as well as a large, language-free display

• The green illuminating D-Light indicates whether the functionality of the device has been tested

• Each sensor variant of the Dräger Pac® series features a clear, well visible color coding, thereby minimizing the chance of mistakes

Dräger Pac® 6000

The Dräger Pac® 6000 disposable personal gas detector measures CO, H2S, SO2 or O2 reliably and precisely, even in the toughest conditions. The robust design, quick sensor response times, and a powerful battery ensure maximum safety for up to two years of 24/7 operation (1 year for O2) with virtually no maintenance required.

• DR-4594501

• NLB-517

• DR-4594501

• NLB-417

• DR-4594501

• NLB-517

• DR-4594501

Dräger Pac® 6500

The robust Dräger Pac® 6500 is your reliable companion under tough conditions. The personal single-gas detection device measures CO, H2S, SO2 or O2 quickly and precisely. Quick sensor response times and a replaceable battery also ensure safety. It features a full data logger, exposure alarms (STEL/TWA) and a powerful battery for 2 years of 24/7 operation (1 year for O2).

AIR MONITORING 42 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM
Part Number Description Measuring Range Resolution Calibration Equipment DR-8327615 Dräger Pac® 6500 For Carbon Monoxide (CO) 0 - 2000 ppm 1 ppm • NLB-H1016100PN
NLB-417
DR-4594501 DR-8327613 Dräger Pac® 6500 For Hydrogen Sulfide (H2S) 0 - 100 ppm 0.1 ppm • NLB-F105325PN
NLB-517
DR-4594501 DR-8327616 Dräger Pac® 6500 For Oxygen (O2) 0 - 25% Vol. 0.1% Vol.
NLB-H107217VN
NLB-417
DR-4594501 DR-8328274 Dräger Pac® 6500 For Sulphur Dioxide (SO2) 0 - 100 ppm 0.1 ppm
NLB-F107910PN
NLB-517
DR-4594501 Part Number Description Measuring Range Resolution Calibration Equipment DR-8327611 Dräger Pac® 6000 For Carbon Monoxide (CO) 0 - 2000 ppm 1 ppm
NLB-H1016100PN
NLB-417
DR-8326368 Dräger Pac® 6000 For Hydrogen Sulfide (H2S) 0 - 100 ppm 0.1 ppm
NLB-F105325PN
DR-8327612 Dräger Pac® 6000 For Oxygen (O2) 0 - 25% Vol. 0.1% Vol.
NLB-H107217VN
DR-8328273 Dräger Pac® 6000 For Sulphur Dioxide (SO2) 0 - 100 ppm 0.1 ppm
NLB-F107910PN
*Fully configurable Dräger Pac® 6000 single gas monitor also available *Fully configurable Dräger Pac® 6500 single gas monitor also available

Dräger Pac® 8000

With the robust Dräger Pac® 8000, you’ll be well equipped for tough conditions: this non-disposable, personal single-gas detection device is a reliable and precise instrument, which detects hazardous concentrations of twenty nine different gases, including special gases like NO2, O3 or COCl2. It features a full data logger, exposure alarms (STEL/TWA) and a powerful battery for 2 years of 24/7 operation.

• NLB-517SS

• DR-4594118

• NLB-F105110PN

• NLB-517

• DR-4594501 DR-8328277

• NLB-517SS

• DR-4594118

• NLB-F2199.5PN

• NLB-517

• DR-4594501 DR-8326356

• DR-4594501

Dräger Pac® 8500

The Dräger Pac® 8500 single-gas detection device is a reliable and precise instrument even under the toughest of conditions. The detector can be equipped with a hydrogen-compensated CO sensor or a Dräger dual sensor. The dual sensors provide the option of measuring two gases at once: either H2S with CO or O2 with CO. It features a full data logger, exposure alarms (STEL/TWA) and a powerful battery.

43 AIR MONITORING AIR MONITORING
Part Number Description Measuring Range Resolution Calibration Equipment DR-8326350 Dräger Pac® 8000 For Nitric Oxide (NO) 0 - 200 ppm 1 ppm • NLB-F166025PN • NLB-517
DR-4594501 DR-8328275 Dräger Pac® 8000 For Nitrogen Dioxide (NO2 LC) 0 - 50 ppm 0.02 ppm • NLB-F106710PN
NLB-517
DR-4594501 DR-8326351 Dräger Pac® 8000 For Carbon Dioxide (CO2) 0 - 5% Vol. 0.1% Vol.
NLB-H10132.5VN
NLB-417
DR-4594501 DR-8326352 Dräger Pac® 8000 For Chlorine (CL2) 0 - 20 ppm 0.1 ppm
NLB-ZB10175PN
DR-8328276 Dräger Pac® 8000 For Hydrogen Cyanide (HCN) 0 - 50 ppm 0.1 ppm
Dräger Pac® 8000 For Ammonia (NH3) 0 - 300 ppm 1 ppm
• NLB-F100550PN
Description Dräger Pac® 8000 For Phosphine (PH3) 0 - 20 ppm 0.1 ppm
DR-8326355
Dräger Pac® 8000 For Organic Vapours (OV) 0 - 200 ppm 0.5 ppm • NLB-F104010PN
NLB-517
DR-8326357 Dräger Pac® 8000 For Organic Vapours (OV-A) 0 - 200 ppm 1 ppm • NLB-F104010PN
NLB-517
DR-4594501 DR-8326359 Dräger Pac® 8000 For Ozone (O3) 0 - 10 ppm 0.01 ppm Contact us for more information DR-8326360 Dräger Pac® 8000 For Phosgene (COCl2) 0 - 10 ppm 0.01 ppm Contact us for more information *Fully configurable Dräger Pac® 8000 single gas monitor also available *CO alarms for these devices are set to: A1 35 ppm and A2 50 ppm *Fully configurable Dräger Pac® 8500 single gas monitor also available Part Number Description Measuring Range Resolution Calibration Equipment DR-8326365 Dräger Pac® 8500 For Hydrogen Sulfide / Carbon Monoxide (H2S LC/CO LC)* 0 - 2000 ppm CO / 0 - 100 ppm H2S 1 ppm CO / 0.1 ppm H2S • NLB-F105325PM73
NLB-517
DR-4594501 DR-8326366 Dräger Pac® 8500 For Oxygen / Carbon Monoxide (O2/CO LC)* 0 - 25% Vol. O2 / 0 - 2000 ppm CO 0.1% Vol. O2 / 1 ppm CO • NLB-F105325PM73
NLB-517
DR-4594501 DR-8328262 Dräger Pac® 8500 For Carbon MonoxideHydrogen Compensated (CO H2-CP) 0 - 2000 ppm 2 ppm • NLB-H1049500PA
NLB-417
DR-4594501

DR-8325646 GasVision 7 Software License

DR-5600704 USB Communication Cradle For Dräger Pac® Monitors

DR-8318587 Communication Cradle & USB Cable

DR-8317410 Dräger Pac® Bump Test/Calibration Station (Gas Cylinder Sold Separately)

DR-8318588 Bump Test/Calibration Adaptor (Hose, Regulator & Gas Cylinder Sold Separately)

DR- 8321881 Dräger X-dock® 5300 Pac Station, Set Consisting Of One Master (Up To 3 Gases) With Power Supply & One Instrument Module For the Dräger Pac® Series 6000/6500/8000/8500 (Regulator Sold Separately)

NLB-F105110PN

NLB-F100550PN

NLB-F104010PN

Gas 10 ppm Ethylene Oxide (For OV Sensors)

AIR MONITORING 44 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM
Description
Part Number
Calibration Gas 100 PPM CO In N2, 34
NLB-F105325PN Calibration Gas 25 PPM H2S In N2, 34 Liter Aluminum Cylinder With CGA C-10 NLB-H107217VN Calibration Gas 17% O2 In N2, 34 Liter Steel Cylinder With CGA 600 NLB-F107910PN Calibration Gas 10 PPM SO2 In N2, 34 Liter Aluminum Cylinder
NLB-F166025PN Calibration Gas 25 ppm NO In N2, 34 Liter Aluminum Cylinder With CGA C-10
Calibration Gas 10 ppm NO2 In N2, 34 Liter Aluminum Cylinder With CGA C-10 NLB-H10132.5VN Calibration Gas 2.5% Vol. CO2 In N2, 34 Liter Steel Cylinder With CGA 600
Calibration Gas 5 ppm CL2 In N2, 58 Liter Aluminum Cylinder
NLB-H1016100PN
Liter Steel Cylinder With CGA 600
With CGA C-10
NLB-F106710PN
NLB-ZB10175PN
With CGA C-10
Calibration
10
HCN
2
Gas
ppm
In N
, 34 Liter Aluminum Cylinder With CGA C-10
Calibration Gas 50 ppm NH3 In N2
34
Calibration Gas 0.5 ppm PH3 In N2
,
Liter Aluminum Cylinder With CGA C-10 NLB-F2199.5PN
, 34 Liter Aluminum Cylinder With CGA C-10
Calibration
in N2, 34 Liter Aluminum Cylinder With CGA C-10 NLB-F105325PM73 Calibration Gas 25 PPM H2S / 100 PPM CO / 2.5% CH4 (50% LEL) / 17% O2 In N2, 34 Liter Aluminum Cylinder With CGA C-10 NLB-H1049500PA Calibration Gas 500 ppm H2 In Air, 34 Liter Steel Cylinder With CGA 600 NLB-417 0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA 600 NLB-517 0.5 LMP Regulator With Gauge & Knob For Cylinders With CGA C-10 DR-4594501 10 ft Tygon® Sampling Hose DR-4594118 5 ft PTFE Lined Reactive Gas Sampling Hose NLB-500D Case For 17 / 29 / 34 Liter Steel Cylinders, Holds 2 Cylinders NLB-505 Case For 58 / 103 / 116 Liter Aluminum Cylinders, Holds 2 Cylinders Accessories & Calibration Equipment ASK FOR YOUR FREE RENTAL CATALOG TODAY SERVICE & CALIBRATE your instruments with our Authorized Service Center! Trust our Knowledgeable Customer Service Representatives to help you determine what equipment is best for your applications! Inf Z ne Call our toll free: 1-888-287-3732

Fully Configurable Dräger X-am® 5100 Single Gas Monitor

Dräger X-am® 5100

The Dräger X-am® 5100 is a small lightweight single gas monitor which is specifically designed for the requirements of personal monitoring. It can be equipped with an electrochemical sensor for hydrazine, hydrogen fluoride / hydrogen chloride or hydrogen peroxide.

For manufacturing petrochemical products, aseptic packing, or handling of rocket fuel: the Dräger X-am® 5100 portable single-gas detector ensures safe handling of HF, HCl, H2O2 or hydrazine - thanks to proven Dräger sensor technology and a device design which is perfectly customized to reactive gases.

It’s as simple as 1, 2, 3...
45 AIR MONITORING AIR MONITORING
Step 2 Choose 0-1 XS DrägerSensor® Part Number Description Measuring Range Resolution DR-6809190 XS DrägerSensor® For Hydrazine (N2H4) XS 0 - 3.00 ppm 0.01 ppm DR-6809140 XS DrägerSensor® For Hydrogen Fluoride / Hydrogen Chloride (HF/HCl) XS 0 - 30.0 ppm 0.1 ppm DR-6809170 XS DrägerSensor® For Hydrogen Peroxide (H2O2) XS 0 - 20.0 ppm 0.1 ppm Step 1 Configurable X-am® 5100 Part Number Description DR-8322750 X-am® 5100 Without Sensors Or Battery Part Number Description DR-8322237 Alkaline Battery Holder (Requires 2 "AA" Alkalines) DR-8318704 NiMH Battery Pack DR-8318785 NiMH Battery & Charger Kit DR-8322244 High Capacity NiMh Battery Pack DR-8322785 High Capacity NiMh Battery & Charger Kit Step 3 Choose Battery Type Part Number Description DR-8317409 USB-IR Communication Cable DR-8325646 GasVision 7 Software License DR-6806291 Calibration Adapter With 3 ft Of Tubing DR-4543755 Deluxe Instrument Transport Case For X-am® 1/2/5000 DR-4543936 High Visibility Yellow Heavy-Duty Transport Case DR-4594631 Nylon Transport Case Accessories

GX-2009 Personal Multi-Gas Monitor

The GX-2009 simultaneously monitors and displays LEL, O2, CO, and H2S. The GX-2009 is also functional with the SDM-2009 single calibration station and the Data Cal 2000 instrument maintenance system. It is designed around RKI’s compact and proven sensors, utilizing catalytic combustion, electrochemical and galvanic sensor technologies.

Applications

• Personal monitoring

• Confined spaces

• Refineries / petrochemical

• Oil & gas

• Utilities

• Hazardous material

• Water/waste water treatment

• Fire services

• Construction

Kit Includes

• GX-2009 monitor

• Wrist strap

• Alligator clip

• 115/220 VAC adapter for charger

• (2) NiMH battery set with hardware

• BC-2009 charging station base only

Features

• Simultaneous detection of 4 gases, LEL, O2, H2S & CO

• STEL and TWA readouts

• Dual audible alarm ports (95 db @ 30 cm)

• 3 visual alarm LED’s

• Vibration alarm

• Calibration and bump test lock out or reminder controls

• Large capacity data logging standard

• 8 alarm trends

• Log time range of 10 to 300 hours

• 100 calibration records stored

• Automatic backlighting at alarm

• Impact resistant rubber over-mold body, RFI shielded body

• IP-67 water-resistant/dustproof design

Safety Rating IECEx zone 0 Ex ia IIC T4; ATEX II 1G Ex ia IIC T4; (optional MSHA version also available)c CSA us classified, as intrinsically safe. Class I, Division 1, Groups A, B, C, D

AIR MONITORING 46 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM
Part Number Description Calibration Equipment RK-72-0314RKC GX-2009 4-Gas Personal Monitor For LEL/O2/H2S/CO With Alligator Clip & 115/220 VAC Charger • NLB-Z105325PM51 • NLB-517 • RK-81-1107RK
RK-06-1248RK-03
RK-03NLB-505 *Other configurations are also available *GX-2009 personal multi-gas monitor mining version also available Part Number Description RK-81-SDM2009-01 SDM 2009 Single Point Calibration Station For GX-2009 With AC Adaptor, Flash Drive, USB Cable & Tubing NLB-Z105325PM51 Calibration Gas 25 PPM H2S / 50 PPM CO / 2.5% CH4 (50% LEL) / 12% O2 In N2, 58 Liter Aluminum Cylinder With CGA C-10 NLB-517 0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA C-10 RK-81-1107RK Rubber Calibration Sample Cap For GX-2009 RK-06-1248RK-03 3/16" I.D. x 5/16" O.D. Polyurethane Calibration Tubing, 3 ft NLB-505 Case For 58 / 103 / 116 Liter Aluminum Cylinders, Holds 2 Cylinders PC-915-1001 Black NANUK™ Case 915 With Cubed Foam (Other Colors Available Upon Request) Accessories & Calibration Equipment Model GX-2009 Gas Detected Combustible Gases (Methane (CH4) as standard) Oxygen (O2) Hydrogen Sulfide (H2S) Carbon Monoxide (CO) Detection Principal Catalytic Combustion Galvanic Cell Electrochemical Cell Detection Range (Increments) 0 - 100% LEL (1% LEL) 0 - 40% Vol. (0.1% Vol. ) 0 - 100 ppm (0.5 ppm) 0 - 500 ppm (1 ppm) Accuracy (Whichever Is Greater) ± 5% of reading or ±2% LEL ± 0.5% O2 ± 5% of reading or ± 2 ppm H2S ± 5% of reading or ± 5 ppm CO
Method Diffusion
Power Source
Operating Temp. & Humidity -20°C ~ +50°C (-4°F
122°F),
Sampling
sampling standard / hand aspirator or motorized pump optional
(2) direct charging NiMH batteries
to
0 to 95% RH, non-condensing (splash resistant)

World’s Smallest & Lightest 4 Gas Monitor

GX-3R Personal 4-Gas Confined Space Monitor

The GX-3R simultaneously monitors and displays LEL combustibles, O2, CO (H2 compensated CO also available) and H2S. The LEL sensor has a unique design with two active filaments in one sensor to increase its resistance to silicone poisoning. If one filament gets poisoned the second filament takes over.

Features

• Simultaneous detection of 4 gases: LEL, O2, H2S & CO (H2 Compensated CO sensor available)

• Simple 2-button operation

• 3 user adjustable alarm levels

• Audible, visual & vibration alarms

• Non-compliance indicator

• Large LCD Auto-backlit display

• Field replaceable sensors & filters

• Impact resistant body with removable rubber boot

• Water and dust resistant design, IP66/68

Applications

• Personal monitoring

• Confined spaces

• Refineries / petrochemical

• Oil & gas

• Utilities

• Hazardous material

• Water/waste water treatment

• Fire services

• Construction

47 AIR MONITORING AIR MONITORING
Kit Includes
GX-3R monitor
Wrist strap
Alligator clip
Rubber boot
Calibration adapter
Li-Ion battery pack
100-240 VAC charger Part Number Description Calibration Equipment RK-72-RA-C GX-3R 4-Gas Personal Monitor For LEL/O2/Combo H2S & CO With Li-Ion Battery Pack & 100-240 VAC Charger
NLB-Z105325PM51
NLB-513
RK-06-1248RK-03
NLB-505
configurations are also available Part Number Description RK-81-SDM3R101 SDM-3R Calibration Station With 1 Solenoid, AC Adapter, Flash Drive, USB Cable & Tubing NLB-Z105325PM51 Calibration Gas 25 PPM H2S / 50 PPM CO / 2.5% CH4 (50% LEL) / 12% O2 In N2, 58 Liter Aluminum Cylinder With CGA C-10 NLB-513 0.25 LPM Regulator With Gauge & Knob For Cylinders With CGA C-10 RK-06-1248RK-03 3/16" I.D. x 5/16" O.D. Polyurethane Calibration Tubing, 3 ft NLB-505 Case For 58 / 103 / 116 Liter Aluminum Cylinders, Holds 2 Cylinders PC-915-1001 Black NANUK™ Case 915 With Cubed Foam (Other Colors Available Upon Request) Accessories & Calibration Equipment *Optional RP-3R clip-on sample drawing pump also available. Model GX-3R Gas Detected Carbon Monoxide (CO) H2 Compensated Carbon Monoxide (CO) Hydrogen Sulfide (H2S) Hydrogen Sulfide (H2S) Only Combustible Gases (Methane (CH4) as standard Oxygen (O2) Dual Sensor Sensor Slot 1 2 3 Detection Principal Electrochemical Cell Dual Electrochemical Cell Electrochemical Cell Catalytic Combustion Electrochemical Cell Detection Range (Increments) 0 ~ 2,000 ppm (1 ppm) • 0 ~ 2,000 ppm CO (1 ppm) • 0 ~ 200.0 ppm H2S (0.1 ppm) 0 ~ 200.0 ppm H2S (0.1 ppm) 0 ~ 100% LEL (1% LEL) 0 ~ 40.0% Vol. (0.1% Vol.) Accuracy (Whichever Is Greater) ± 5% of reading or ± 2 ppm CO • ± 5% of reading or ± 5 ppm CO • ± 5% of reading or ± 2 ppm H2S ± 5% of reading or ± 2 ppm H2S ± 5% of reading or ± 2% LEL ± 5% CO2 Power Source Li-Ion
Sampling Method Diffusion sampling standard /
motorized
Operating Temp. & Humidity -20°C ~ +50°C [ -4°F ~ +122°F ], 10 to 90% RH, non-condensing (continuous environment) -40°C ~ +60°C [ -40°F ~ +140°F ], 0 to 95% RH, non-condensing
minutes) Safety Rating ATEX, CSA (Pending)
*Other
battery pack
hand aspirator or
pump optional
(temporary environment, 15

World’s Smallest & Lightest 5 Gas Monitor

GX-3R Pro Personal 4-Gas + Toxic Gas Monitor With Bluetooth

The GX-3R Pro simultaneously monitors and displays 5 different gases. In addition to monitoring standard confined space gases LEL, O2, CO, & H2S, the GX-3R Pro has a 5th channel where you can add infrared or toxic sensors. Two of the four sensor slots have interchangeable sensors providing flexible configurations, which can easily be changed in the field.

The GX-3R Pro utilizes Bluetooth communication to display direct gas readings from the instrument to a phone app, which is available free on either iOS or Android phones. Automatic notifications can be programmed to send text or email messages, if there is an alarm event from the GX-3R Pro.

with iOS and Android phone app: RK Link

Understanding the features of the GX-3R Pro

AIR MONITORING 48 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM
Model GX-3R Pro Gas Detected Hydrogen Sulfide / Carbon Monoxide (H2S / CO) Hydrogen Sulfide (H2S) Only Carbon Monoxide (CO) H2 Compensated Combustible Gases (Methane) / Hydrocarbons (CH4 / HC) Sensor Slot 1: Carbon Monoxide (CO) & Hydrogen Sulfide (H2S) *Interchangeable 2: Combustible Gases (Methane (CH4) as standard) Detection Principal Dual Electrochemical Cell Electrochemical Cell Catalytic Combustion Detection Range (Increments) 0 ~ 2000 ppm (1 ppm) 0 ~ 200.0 ppm (0.1 ppm 0 ~ 200.0 ppm (0.1 ppm) 0 ~ 2,000 ppm 0 ~ LEL (1% LEL) Accuracy (Whichever Is Greater) ±
or
±
±
±
Sampling Method Diffusion sampling
Power Source (Configurable) Li-ion or Alkaline Operating Temp. & Humidity -20°C ~ +50°C [ -4°F ~ +122°F ] 10 to 90% RH, non-condensing
-40°C ~ +60°C [ -40°F ~ +140°F ] 0 to 95% RH,
Bluetooth Communication BLE:
Safety Rating ATEX,
5% of reading
± 5 ppm CO
5% of reading or ± 2 ppm H2S
5% of reading or ± 2 ppm H2S
5% of reading or ± 2 ppm CO ± 5% of reading or ± 2 % LEL
standard (hand aspirator or clip-on motorized pump optional)
(continuous environment)
non-condensing (temporary environment)
CSA

Applications

• Personal monitoring

• Confined spaces

• Refineries / petrochemical

• Utilities

• Oil & gas

• Water/waste water treatment

• Fire Services

• Law Enforcement

• Construction

AUTHORIZED RKI SERVICE CENTER

Features

• Simultaneous detection of 5 gases

• LEL, O2, H2S, CO, and other optional sensors

• H2 Compensated CO sensor available

• Simple 2-button operation

• Bluetooth communication with iOS & Android App

• 3 user adjustable alarm levels

• Panic alarm (tap instrument twice)

• Man down alarm

• Non-compliance indicator

• Large full dot, auto-backlit display with auto-rotation

• Stealth mode for law enforcement

• Field replaceable sensors & filters

• Impact resistant body with removable rubber boot

• Water and dust resistant design, IP66/68

Kit Includes

• GX-3R monitor

• Wrist strap

• Alligator clip

• Rubber boot

• Calibration adapter

• Li-Ion battery pack

• 100-240 VAC charger

Diffusion sampling standard (hand aspirator or clip-on motorized pump optional)

Li-ion or Alkaline

-20°C ~ +50°C [ -4°F ~ +122°F ] 10 to 90% RH, non-condensing (continuous environment)

-40°C ~ +60°C [ -40°F ~ +140°F ] 0 to 95% RH, non-condensing (temporary environment)

BLE: with iOS and Android phone app: RK Link

ATEX, CSAw

49 AIR MONITORING AIR MONITORING
Part Number Description RK-81-SDM3R201 SDM-3R Calibration Station With 2 Solenoids (For 2 Cylinders), AC Adapter, Flash Drive, USB Cable & Tubing NLB-Z105325PM51 Calibration Gas 25 PPM H2S / 50 PPM CO / 2.5% CH4 (50% LEL) / 12% O2 In N2, 58 Liter Aluminum Cylinder With CGA C-10 NLB-Z10135000PN Calibration Gas 5000 PPM CO2 In N2, 58 Liter Aluminum Cylinder With CGA C-10 NLB-513 0.25 LPM Regulator With Gauge & Knob For Cylinders With CGA C-10 RK-06-1248RK-03 3/16" I.D. x 5/16" O.D. Polyurethane Calibration Tubing, 3 ft NLB-505 Case For 58 / 103 / 116 Liter Aluminum Cylinders, Holds 2 Cylinders PC-915-1001 Black NANUK™ Case 915 With Cubed Foam (Other Colors Available Upon Request) Part Number Description Calibration Equipment RK-72-PAA-C GX-3R Pro 5-Gas Personal Monitor For LEL/O2/Combo H2S & CO/ppm CO2 With Li-Ion Battery Pack & 100-240 VAC Charger
NLB-Z105325PM51
NLB-Z10135000PN
NLB-513
RK-06-1248RK-03
NLB-505 *Other configurations are also available Accessories & Calibration Equipment *Optional RP-3R clip-on sample drawing pump also available GX-3R Pro Oxygen (O2) Hydrogen Cyanide (HCN) Nitrogen Dioxide (NO2) Sulfur Dioxide (SO2) Carbon Dioxide % (CO2) Carbon Dioxide ppm (CO2) 3: Oxygen (O2) 4: Toxics & CO2 Electrochemical Cell Infrared
~ 40.0% Vol. (0.10%) 0 ~ 30.0 ppm (0.1 ppm) 0 ~ 20.00 ppm (0.05 ppm) 0 ~ 100.0 ppm (0.05 ppm) 0 ~ 10.0% Vol. (0.01%) 0 ~ 10,000 ppm (20 ppm)
0.5% O2 ± 10% of reading or ± 5 % of full
± 5% of
0
±
scale
reading or ± 2 ppm

Remote Sample Drawing Pump For GX-3R & GX-3R Pro

RP-3R Clip-On Sample Drawing Pump

The RP-3R are compact, battery operated, motorized sample drawing pumps which attach to either the GX-3R or the GX-3R Pro to change them from diffusion operation to sample drawing operation. The model RP-3R pumps and the GX-3R or GX-3R Pro gas monitor make a complete solution for confined space entry.

• Attaches to the GX-3R in seconds (RP-3R Pro for the GX-3R Pro)

• Compact and lightweight

• 10 hours of operation in normal mode (higher flow mode)

• 16 hours of operation in lower-flow mode (ECO mode)

• Audible and visual alarms for low flow and low battery conditions

• Pilot light to confirm operation

• Quick disconnect fitting for hose connection

• Hoses available up to 100’ length

• Rugged and proven RKI reliability

Kit Incudes

• 4" tapered red rubber nozzle

• "AA" Alkaline battery

• Hydrophobic filters

to + 122°F (no sudden change)

(body only)

Weight 4.58 oz

Explosion Proof Intrinsically safe construction, ATEX/IECEx

Standard Accessories

4" tapered red rubber nozzle, AA alkaline battery, & hydrophobic filters

Optional Accessories 10 ft – 100 ft hose, 10" probe with dust filter

AIR MONITORING 50 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM
Z ne Differences Between The 3 Operating Modes Of The GX-2012
Inf
confined space,
monitoring applications
"Normal Operating" mode is used for
safety
leak investigation applications
"Leak Check" mode is used for
used for underground leak checking applications
"Bar Hole" mode is
Features
Model
Flow Rate Higher flow mode: 0.5 l/m Lower flow mode (ECO mode): 0.35
Alarm Display Low flow alarm: Flow
YELLOW Low
alarm: Power LED
GREEN Power Supply 1
Operation Higher
Lower flow
Operating Temperature
Operating Humidity Range 95%
External Dimensions 3.23" (W) x 3.78" (H) x
RP-3R
l/m
blinks
battery
blinks
AA alkaline battery Continuous
flow mode: 10 hours
mode (ECO mode): 16 hours
-4°F
RH or less (without condensation)
1.14" (D)
Part Nunber Description RK-81-1197 RP-3R Pump For GX-3R RK-81-1198 RP-3R Pump For GX-3R With 10 ft Hose & 10" Probe RK-81-1198-20 RP-3R Pump For GX-3R With 20 ft Hose & 10" Probe
RP-3R Pump For GX-3R With 30 ft Hose & 10" Probe RK-81-1199 RP-3R Pro Pump For GX-3R Pro RK-81-1200 RP-3R Pro Pump For GX-3R Pro With 10 ft Hose & 10" Probe RK-81-1200-20 RP-3R Pro Pump For GX-3R Pro With 20 ft Hose & 10" Probe
RK-81-1198-30

Excellent For Gas Line Purge Testing

GX-2012 5-Sensor Sample Draw Confined Space Multi-Gas Monitor With CSA Approval

Built around high-quality micro-sensor technology, the GX-2012 is RKI’s smallest personal 1-5 sensor gas monitor with a built in sample pump.

Features

• Monitors ppm LEL, % Vol. CH4, O2, CO and H2S

• 0 - 100% Vol. CH4 option

• Auto-ranging display of % LEL and % Vol.

• (3) operating modes: normal, leak check, & bar hole

• PPM leak detector

• Adjustable display ranges

• Visual / audible pulses change with gas concentration

• CO display in leak check mode

• Barhole test mode for underground leak checks

• Status indicators: pump active, microprocess or status and battery level

• Internal sample drawing pump with up to 50 ft range

• Vibration, visual and audible alarms

• Automatic backlight during alarms

• Bump test and calibration reminder with lock out option

• Li-Ion or alkaline battery packs (interchangeable)

• Alarm latching or non-latching

• High impact, dust and water resistant design

• Up to 600 hours of data logging with alarm trends

• Snap-logging on demand data recording

• TWA and STEL readings with lunch-break mode

*Optional

Applications

• Personal monitoring

• Confined space entry

• Refineries / petrochemical

• Chemical plants

• Hazardous material

• Water/waste water treatment

• Fire services

• Mining

Kit Includes

• GX-2012 monitor

• 10" probe

• 3.5" rubber nozzle

• 10 ft hose

• Belt clip

• 115/220 VAC adapter for charger

• Li-Ion battery pack & 100-240 VAC charger

• Quick reference card

51 AIR MONITORING AIR MONITORING
configurations are also available Part Number Description RK-81-SDM2012-01 Single Point Calibration Station For GX-2012 & Gas Tracer With AC Adaptor, Flash Drive, USB Cable & Tubing NLB-Z105325PM51 Calibration Gas 25 PPM H2S / 50 PPM CO / 2.5% CH4 (50% LEL) / 12% O2 In N2, 58 Liter Aluminum Cylinder With CGA C-10 NLB-8C10 Demand Flow Regulator For Cylinders With CGA C-10 RK-06-1248RK-03 3/16" I.D. x 5/16" O.D. Polyurethane Calibration Tubing, 3 ft NLB-505 Case For 58 / 103 / 116 Liter Aluminum Cylinders, Holds 2 Cylinders PC-915-1001 Black NANUK™ Case 915 With Cubed Foam (Other Colors Available Upon Request)
*Other
Accessories & Calibration Equipment
clip-on sample drawing pump also
Part Number Description Calibration Equipment RK-72-0292-22-C GX-2012 4-Gas Detector For LEL/O2/H2S/CO With Li-Ion Battery Pack & 100-240 VAC Charger
RP-3R
available
NLB-Z105325PM51
NLB-8C10
RK-06-1248RK-03
NLB-505
Model GX-2012 Gas Detected Combustible Gases (Methane (CH4) as standard) % Vol. Methane (CH4) Oxygen (O2) Hydrogen Sulfide (H2S) Carbon Monoxide (CO) Detection Principal Catalytic Combustion Thermal Conductivity Galvanic Cell Electrochemical Cell Detection Range • 0 ~ 100% LEL • 0 ~ 500/1,000/2,000/ 5,000 ppm 0 ~ 100% Vol. 0 ~ 40% Vol. 0 ~ 100 ppm (optional 0 - 500 ppm) 0 ~ 500 ppm Accuracy (Whichever Is Greater) ± 5% of reading or ± 2% LEL (LEL mode only) ± 5% of reading or ± 2% of full scale CH4 ± 5% O2 ± 5% of reading or ± 2 ppm H2S ± 5% of reading or ± 5 ppm CO Sampling Method Internal sample pump, flow rate nominal 0.5 LPM, includes hydrophobic filter Power Source Li-Ion battery pack or (3) "AA" Alkaline battery pack (interchangeable) Operating Temp. & Humidity -20°C to +50°C (-4°F to 122°F), 0 to 95% RH, non-condensing Safety Rating ATEX, TIIS, IECEx, CE, CSA classified (as standard), as intrinsically safe. Class I, Division 1, Groups A, B, C, D (optional version available)

Excellent For Gas Line Purge Testing & Detection Of Small Gas Leaks

Gas Tracer Confined Space Multi-Gas / Leak Detector

Built around high-quality micro-sensor technology, the Gas Tracer is RKI’s smallest personal 5-sensor monitor with a built in sample pump.

Features

• Monitors ppm LEL, % Vol. CH4, O2 and CO

• PPM leak detector, detects down to 10 ppm CH4

• "Leak tracker" audible/visual alarm mode for CH4 and CO

• 0 - 100% Vol. CH4 option

• Auto-ranging display of % LEL and % volume

• Barhole test mode

• Bump test reminder option

• Snap-logging - on demand data recording

• Pump pause on demand extends battery life

• Status indicators: pump active, microprocessor status and battery level

• Internal sample drawing pump with up to 50 ft range

• Vibration, visual and audible alarms

• Automatic backlight during alarms

• Calibration reminder with lock out option

• Li-Ion or alkaline battery packs (interchangeable)

• Alarm latching or non-latching

• High impact protective rubber over molding

• Up to 600 hours of data logging with alarm trends

• Auto-calibration or single calibration

• High dust and water resistance design

• TWA and STEL readings with lunch-break mode

Applications

• Personal monitoring

• Confined space entry

• Refineries / petrochemical

• Chemical plants

• Hazardous material

• Water/waste water treatment

• Fire services

• Mining

Kit Includes

• Gas Tracer monitor

• 10" probe

• 2.5" rubber nozzle

• 10 ft hose

• Belt clip

• 115/220 VAC adapter for charger

• Li-Ion battery pack & 100-240 VAC charger

• Quick reference card

Sampling Method Internal sample pump, flow rate nominal 0.5 LPM, includes hydrophobic filter

Power Source Li-Ion battery pack or (3) "AA" Alkaline battery pack (interchangeable)

Operating Temp.

-20°C to +50°C (-4°F to 122°F), 0 to 95% RH, non-condensing

Safety Rating ATEX, TIIS, IECEx, CE, or optionally: c CSA us classified, as intrinsically safe. Class I, Division 1, Groups A, B, C, D

Note: Either ATEX (USA and worldwide) or CSA (Canada) version must be specified when ordering.

Accessories & Calibration Equipment

AIR MONITORING 52 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM
Part Number Description Calibration Equipment RK-72-0291-69-C Gas Tracer 5-Gas Detector For PPM CH4/LEL/% Vol. CH4/O2/CO Base With Li-Ion Battery Pack & 100-240 VAC Charger • NLB-J1971500PA • NLB-Z1971 • NLB-J197150LM4 • NLB-8C10 • RK-33-2001RK-01 • RK-06-1248RK-03 • NLB-500C *Other configurations are also available Model Gas Tracer Gas Detected Combustible Gases (Methane (CH4) as standard) % Vol. Methane (CH4) PPM Methane (CH4) Oxygen (O2) Carbon Monoxide (CO) Detection Principal Catalytic Combustion Thermal Conductivity MOS/Catalytic Galvanic Cell Electrochemical Cell Detection Range 0 ~ 100% LEL 0 ~ 100% Vol. 0 ~ 5000 ppm optional
range
0 ~ 40% Vol. 0 ~ 500 ppm Accuracy (Whichever
Greater) ± 5% of reading or ± 2% LEL ± 5% of reading or ± 2% of full scale CH4 ± 10% of reading
± 50
4 ±
±
reading or ± 5
CO
10,000 ppm
version available
Is
or
ppm CH
5% O2
5% of
ppm
& Humidity
Part Number Description RK-81-SDM2012-01 Single Point Calibration Station For GX-2012 & Gas Tracer With AC Adaptor, Flash Drive, USB Cable & Tubing NLB-J1971500PA Calibration Gas 500 PPM CH4 In Air, 103 Liter Steel Cylinder With CGA C-10 NLB-Z1971 Calibration Gas 100% Vol. CH4, 58 Liter Aluminum Cylinder With CGA C-10 NLB-J197150LM4 Calibration Gas 50 PPM CO / 2.5% CH4 (50% LEL) / 12% O2 In N2, 103 Liter Steel Cylinder With CGA C-10 NLB-8C10 Demand Flow Regulator For Cylinders With CGA C-10 RK-33-2001RK-01 6" Humidifier Tube Assembly For Cal Kits With 3/16" Tubing On Ends RK-06-1248RK-03 3/16" I.D. x 5/16" O.D. Polyurethane Calibration Tubing, 3 ft NLB-500C Case For 58 / 103 / 116 Liter Aluminum Cylinders, Holds 3 Cylinders PC-915-1001 Black NANUK™ Case 915 With Cubed Foam (Other Colors Available Upon Request)

GX-6000 Benzene Specific Gas Detector

Features

• 0.01 - 50 ppm with 10.0 eV PID lamp and pre-filter tube

• Benzene Select Mode takes timed samples using pre-filter tube

• Benzene Filter Tube Holder

• Long break through times for Benzene filter tubes

• 4 PID options: 10.6 eV (2 ranges), 10.0 eV, and 11.7 eV lamp

• Easily switch VOC target gas

• Available with both 10.0 & 10.6 PID sensors

• Monitor up to 6 gases

• 2 smart sensor slots auto recognize PID, IR, and super toxic sensors

• Internal sample pump

53 AIR MONITORING AIR MONITORING Also Available...
Calibration & Accessories Inf Z ne Contact us at 1-888-287-3732 for more information AUTHORIZED RKI SERVICE CENTER

Best Seller!

GX-6000 Up To 6-Gas, Sample Draw Portable Monitor With Choice Of PID, IR & Super Toxic Sensors

The GX-6000 simultaneously monitors up to 6-gases. In addition to the standard 4 confined space gases which include LEL, O2, CO, & H2S, the GX-6000 has 2 additional smart channels that accept PID, IR or super toxic sensors. It can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels. A benzene-specific version is also available using a pre-filter tube for detecting low levels of benzene.

Applications

• Confined space entry

• Hazmat response teams

• Arson investigation

• Remediation site

• Perimeter monitoring

• Leak detection

• Landfill monitoring

• Winery tank entry

AIR MONITORING 54 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM
Kit Includes
GX-6000 monitor
Probe attached with 3 ft teflon lined hose
Tapper nozzle
Belt clip
Hand strap
Rubber boot
Hydrophobic & dust filter
115/220 VAC adapter for charger
Li-Ion battery pack & 100-240 VAC charger
Quick reference card
AUTHORIZED RKI SERVICE CENTER
Model Name GX-6000 Gas Detected 600 VOC’s Benzene Specific 300 VOC’s High Voltage Lamp Oxygen (O2) Carbon Monoxide (CO) Hydrogen Sulfide (H2S) Detection Principal PID Sensors Galvanic Cell Electrochemical Cell Detection Range 0 - 50,000 ppb 0.1 - 50 ppm 0 - 100 ppm 0 - 1000 ppm 0 - 40.0% Vol. 0 - 500 ppm 0 - 100.0 ppm 0 - 6,000 ppm Accuracy ± 10% of reading, ± 1 digit ± 0.5% O2 ± 5% of reading or ± 5 ppm CO ± 5% of reading or ± 2 ppm H2S Sampling Method Sample draw pump, flow rate 0.45 LPM, 50 foot sample range Power Source (Configurable) Li-ion or Alkaline Operating Temp. & Humidity -20°C ~ +50°C (-4°F to 122°F ), 0- 95% RH non condensing
Rating
Explosion
Ga
Safety
Explosion proof: IECEx , ATEX , TIIS , cCSAus
class: Ex ia IIC T4
Others: CE Marking

Sample Draw with PID, IR, O2, CO, H2S, VOC & Super Toxic Sensor Options

Features

• Monitors up to 6 gases

• Two smart sensor slots auto recognize PID, IR and super toxic sensors

• Six operating modes: normal, leak check, benzene select mode, inert, snap log and bar hole

• Four PID options: 10.6 (2 ranges) eV, 10.0 eV, and 11.7 eV lamps

• PID library of over 600 VOCs

• Benzene specific version

• PPM leak check mode

• LEL sensor protection mode

• Man-down alarm

• Panic alarm, auto display rotation

• Peak-bar display

• LED Light source

• Internal sample pump

• Light weight, small, rugged IP-67 design

• Li-Ion or alkaline battery packs (interchangeable)

• Field replaceable sensors, batteries, filters and pump

-20°C ~ +50°C (-4°F to 122°F ), 0- 95% RH non condensing

Explosion proof: IECEx , ATEX , TIIS , cCSAus

Explosion class: Ex ia IIC T4 Ga Others: CE Marking

*Other configurations are also available

55 AIR MONITORING AIR MONITORING
Part Number Description Calibration Equipment RK-72-6ABX-C GX-6000 For LEL/ O2/H2S/CO/VOCs (0-6,000 ppm PID) With Li-Ion Battery Pack & 100-240 VAC Charger • NLB-J1055100PA
NLB-Z105325PM51
NLB-8C10
RK-06-1248RK-03
NLB-505
Part Number Description RK-81-SDM6000-01 SDM-6000 Calibration Station For GX-6000 With Particle Filter, Connection Brackets, SD Card, USB SD Card Reader, Ethernet Cable, USB Cable For PC, 10’ Exhaust Tubing & Single Unit AC Adapter NLB-Z105325PM51 Calibration Gas 25 PPM H2S / 50 PPM CO / 2.5% CH4 (50% LEL) / 12% O2 In N2, 58 Liter Aluminum Cylinder With CGA C-10 NLB-J105100PA Calibration Gas 100 PPM Isobutylene In Air, 103 Liter Aluminum Cylinder With CGA C-10 NLB-8C10 Demand Flow Regulator For Cylinders With CGA C-10 RK-06-1248RK-03 3/16" I.D. x 5/16" O.D. Polyurethane Calibration Tubing, 3 ft NLB-505 Case For 58 / 103 / 116 Liter Aluminum Cylinders, Holds 2 Cylinders PC-920-1001 Black NANUK™ Case 920 With Cubed Foam (Other Colors Available Upon Request)
& Calibration Equipment
Accessories
GX-6000 Ammonia (NH3) Chlorine (Cl2) Hydrogen Cyanide (HCN) Nitrogen Dioxide (NO2) Sulfur Dioxide (SO2) Carbon Dioxide (CO2) Methane (CH4) Hydrocarbons Hydrocarbons (CH4, std) Toxics (Electrochemical Sensors) Infrared (IR Sensors) Catalytic Combustion 0 - 400.0 ppm 0 - 10.00 ppm 0 - 15.0 ppm 0 - 20.00 ppm 0 - 99.90 ppm 0 - 10,000 ppm 0 - 100% LEL 0 - 100% Vol. 0 - 100% LEL 0 - 30% Vol. 0 - 100% LEL 0 - 10.00% Vol. ± 10% of reading or ± 5% of full scale ± 5% of reading or ± 2% of full scale ± 5% of reading or ± 2% LEL Sample draw pump, flow
sample
Li-ion
rate 0.45 LPM, 50 foot
range
or Alkaline

Over 400 Gas Monitoring Configurations

EAGLETM Up To 6-Gas Portable Monitor

The EAGLETM is a powerful instrument that does more than just offer the standard confined space protection for LEL, O2, H2S and CO. Detection combinations never before offered in a portable gas monitor are now available featuring the industry’s widest selection of high quality, long life and field proven sensors. A variety of accessories are also available to help satisfy almost any application such as long sample hoses, special float probes for tank testing, continuous operation adapters, remote alarms and strobes, and dilution fittings, etc.

Applications

• Personal monitoring

• Confined space entry

• Refineries / petrochemical

• Chemical plants

• Hazardous material

• Water/waste water treatment

• Fire services

• Mining

• Line purge testing

• Transformer testing

• Leak investigation

Features

Kit Includes

• EAGLE

• 10" hydrophobic probe (standard gas versions and some super toxic versions only)

• 5 ft polyurethane hose (standard gas versions and some super toxic versions only)

• Shoulder strap with RKI logo

• Internal hydrophobic filter

• (4) "D" alkaline batteries

• Simultaneous detection of up to 6 different gases

• IR Sensors available for CO2, % LEL CH4 or HC, % Vol. CH

• Wide range of toxic gases

• PPM / LEL hydrocarbon detection

• CH4 elimination switch for environmental applications

• Two alarm levels per channel plus TWA and STEL alarms for toxic channels

• Powerful long-life pump up to 125' range with filters

• Dual hydrophobic filters (most versions)

• Transformer testing version available

Accessories & Calibration Equipment

RK-33-0156RK-01

PC-925-1001

Replacement Hydrophobic Filter Element For EAGLETM & EAGLETM 2 Probe, 5/Pack

Black NANUK™ Case 925 With Cubed Foam (Other Colors Available Upon Request)

AIR MONITORING 56 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM
Part Number Description RK-72-5401RK EAGLETM For LEL & PPM/O *Other configurations are also available **Optional & ONLY used if the customer’s intent is to use the Methane elimination mode Part Number Description RK-81-SDME2-01 SDM-E2 Calibration For EAGLETM & EAGLETM 2, With AC Adaptor, Flash Drive, USB Cable & Tubing NLB-Z105325PM51 Calibration Gas 25 PPM H2S / 50 PPM CO / 2.5% CH4 (50% LEL) / 12% O2 In N2, 58 Liter Aluminum Cylinder With CGA C-10 NLB-J120815LA Calibration Gas 15% LEL Hexane In Air, 103 Liter Steel Cyl. With CGA C-10 NLB-8C10 Demand Flow Regulator For Cylinders With CGA C-10 RK-06-1248RK-03 3/16" I.D. x 5/16" O.D. Polyurethane Calibration Tubing, 3 ft
Case For 58 / 103 / 116 Liter Aluminum Cylinders, Holds 2 Cylinders
Ni-Cad Batteries & 115 VAC Charger For EAGLETM
Factory Installed Data Logging Board For EAGLETM (Part # RK-82-5007RK Also Required)
Factory Installed External Methane Elimination Switch For EAGLETM
NLB-505
RK-49-2150RK-01
RK-57-0012RK-01
RK-75-0001RK

Hydrogen

Hydrogen

Hydrogen

Hydrogen

Hydrogen

Hydrogen

Ozone

Nitric

Phosphine

- 100 ppm

- 1 ppm

Silane (SiH4) 0 - 15 ppm

Sulfur Dioxide (SO2) 0 - 6 ppm

Carbon Dioxide

Infrared (IR Sensors)

- 5,000 ppm

2% of full scale

Methane

Isobutane

Detection Principal Catalytic Combustion, Electrochemical Cell, Galvanic Cell & Infrared

Sampling Method Powerful, long-life pump (over 6,000 hours) can draw samples over 125 feet. Flow rate approximately 2.0 SCFH.

Power Source (4) Alkaline or Ni-Cad, size "D" batteries (Charger has alkaline recognition to prevent battery damage if charging is attempted with alkalines.)

Operating Temp. & Humidity -10°C to 40°C (14°F to 104°F), 0 to 95% RH, non-condensing

Safety Rating Intrinsically Safe, Class I, Division 1, Groups A, B, C, D. CSA (C / US) and UL classified (most versions)

57 AIR MONITORING AIR MONITORING EAGLETM Detection Range Accuracy (Whichever Is Greater) Standard Confined Space Gases
(CH4, std) 0 - 100% LEL ± 5% of reading or ± 2% LEL 0 - 50,000 ppm ± 50 ppm or ± 5% of reading 0 - 40% Vol. ± 0.5% O2 Carbon Monoxide (CO) 0 - 500 ppm ± 5% of reading or ± 5
CO Hydrogen Sulfide (H2S) 0 - 100 ppm ± 5% of reading or ± 2 ppm H2S Super Toxics & Other Gases ) 0 - 75 ppm ± 10% of reading or ± 5% of full scale 0 - 1 ppm 0 - 200
0 -
Chlorine Dioxide (ClO2) 0 - 1
0 -
Hydrocarbons
ppm
ppb
3 ppm
ppm
5 ppm
Fluoride (HF) 0
- 9 ppm
Chloride (HCl) 0
- 15 ppm
Cyanide (HCN) 0
- 30 ppm
Peroxide (H
0
2O2)
- 3 ppm
Selenide (H
0
2Se)
- 0.2 ppm
Sulfide (H2S) 0
0 - 30
Dioxide (NO2) 0
- 1 ppm
ppm Nitrogen
- 15 ppm
(O
0
3)
- 1 ppm
Oxide (NO) 0
0
(PH3)
0
-
Vol. 0 - 20% Vol. 0 - 60% Vol.
±
(CO2)
0 - 10,000 ppm 0
5%
± 5% of reading or
(CH
) 0 - 100% LEL 0 - 100% Vol.
4
(iC
H10) 0 - 100% LEL 0 - 30% Vol.
4

Soaring To New Heights! The Legacy Continues With The EAGLETM 2

EagleTM 2 Up To 6-Gas Portable Monitor With Choice Of PID

The EAGLETM 2 is a powerful instrument that does more than just offer the standard confined space protection for LEL, O2, H2S and CO. The EAGLETM 2 available features include a PID sensor for detecting high or low ppm levels (0 - 50 ppm & 0 - 2,000 ppm) of VOC gases; % Vol. capability for CH4 and H2 using a TC (thermal conductivity) sensor; PPM or LEL hydrocarbon detection at the push of a button; infrared sensors for CO2 (ppm or % Vol.), CH4 or hydrocarbons in LEL and % Vol. ranges; CH4 elimination feature for environmental applications; and a variety of super toxic gases. A variety of accessories are also available to help satisfy almost any application such as long sample hoses, special float probes for tank testing, and dilution fittings, etc.

Applications

• Personal monitoring

• VOC monitoring

• Confined space entry

• Refineries / petrochemical

• Chemical plants

• Hazardous material

• Water/waste water treatment

• Fire services

• Mining

• Line purge testing

• Transformer testing

• Leak investigation

Features

• Simultaneous detection of up to 6 different gases

• PPM, % LEL, or % Vol. auto-ranging combustible detection

• Specialty Sensors

• PID (Photoionization Detector): low or high range for VOC detection, fence electrode technology for humidity and contamination resistance

• Infrared (IR): CO2, % LEL CH4, % Vol. CH4, % LEL HC, % Vol. HC

• Thermal Conductivity (TC): % Vol. H2, % Vol. CH4

• Smart toxic, plug and play sensors: NH3, AsH3, Cl2, HCN, PH3, & SO2

• Hydrogen specific LEL / ppm sensor

Kit Includes

• EAGLETM 2 monitor

• 10" hydrophobic probe without particle filter, with metal fittings (used for EAGLETM 2 with PID versions only)

• 5 ft teflon lined hose with fittings (used for EAGLETM 2 with PID versions only)

• Shoulder strap with RKI logo

• Internal hydrophobic filter

• (4) "C" alkaline battery

• Data logging standard

• CH4 elimination for environmental use

• Low flow pump shut off and alarm

• Two alarm levels per channel plus TWA and STEL alarms for toxic channels

• Powerful long-life pump up to 125’ range

• Internal hydrophobic dust filter

• External probe with hydrophobic filter

• Password protection

• Multilingual (5 languages)

• Ergonomic RFI / EMI / chemical / weather resistant enclosure

RK-33-0156RK-01

PC-925-1001

AIR MONITORING 58 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM
Part Number Description Calibration Equipment RK-725-101-P2 EAGLETM 2 For LEL & PPM/ O2/CO/H2S/VOCs (0 - 2,000 ppm PID) • NLB-Z105325PM51
NLB-J1055100PA
NLB-8C10
RK-06-1248RK-03
NLB-505
configurations are also available Part Number Description RK-81-SDME2-01 SDM-E2 Calibration For EAGLETM & EAGLETM 2, With AC Adaptor, Flash Drive, USB Cable & Tubing NLB-Z105325PM51 Calibration Gas 25 PPM H2S / 50 PPM CO / 2.5% CH4 (50% LEL) / 12% O2 In N2, 58 Liter Aluminum Cylinder With CGA C-10 NLB-J105100PA Calibration Gas 100 PPM Isobutylene In Air, 103 Liter Aluminum Cylinder With CGA C-10 NLB-8C10 Demand Flow Regulator For Cylinders With CGA C-10 RK-06-1248RK-03 3/16" I.D. x 5/16" O.D. Polyurethane Calibration Tubing, 3 ft NLB-505 Case For 58 / 103 / 116 Liter Aluminum Cylinders, Holds 2 Cylinders RK-49-2175RK-01 Factory Installed 100-240 VAC Battery Charger With (4) "C" NiMH Batteries For EAGLETM 2
*Other
Hydrophobic Filter Element For EAGLETM & EAGLETM 2 Probe, 5/Pack
Replacement
Black NANUK™ Case 925 With Cubed Foam (Other Colors Available Upon Request)
Calibration Equipment
Accessories &
AUTHORIZED RKI SERVICE CENTER

Hydrocarbons

- 50,000 ppm

Ammonia (NH3)

Arsine (AsH3)

Chlorine (Cl2)

Hydrogen Cyanide (HCN)

Phosphine (PH3)

Sulfur

VOC

Methane

5% of reading

5 ppm CO

ppm H2S Toxics

- 75 ppm

- 1.5 ppm

- 3 ppm

- 15 ppm

- 1 ppm

- 6 ppm Infrared (IR Sensors)

- 100% LEL/0 - 100% Vol.

- 100% LEL/0 - 30% Vol.

- 2,000 ppm

- 50 ppm

Sensors

TC Sensors

10% of reading or ± 5% of full scale

Hydrogen Specific

Detection Principal Catalytic Combustion, Electrochemical Eell, Galvanic Cell, Infrared, Photoionization Detector & Thermal Conductivity

Sampling Method Powerful, long-life internal pump (over 6,000 hours) can draw samples over 125 feet. Flow rate approximately 2.0 SCFH.

Power Source (4) alkaline or NiMH, size "C" batteries (Charger has alkaline recognition to prevent battery damage if charging is attempted with alkalines.)

Operating Temp. & Humidity -20°C to 50°C (-4°F to 122°F), 0 to 95% RH, non-condensing

Safety Rating Intrinsically Safe, Class I, Groups A, B, C, D. Approvals: CSA / CE

* The EAGLETM 2 can be configured with up to 6 gas sensors from the above list

Inf Z ne

The Major differences

EAGLETM 1

• Ability to detect for more different gases with regard to toxic inorganic compounds, using the large toxic, electrochemical sensors

• Limited as to what sensor configurations it can do, especially when 5 or 6 sensors are considered

• Datalogging is no longer supported

• Longer run time using "D" size batteries (to access the NiCad rechargeable batteries, you must lift off the top case)

• Available for approx. 2 more years

Between The EAGLETM 1 & The EAGLETM 2

VS

EAGLETM 2

• PID capability

• Thermal Conductivity sensor capability, % Vol. as an option to the IR sensors

• Hydrogen specific capability for the % LEL sensor

• Datalogging capabilities is supported

• Shorter run time using "C" size batteries (exterior Alkaline or NiMH battery pack)

59 AIR MONITORING AIR MONITORING Model EAGLETM 2 Gas Detected Detection Range Accuracy (Whichever Is Greater)
Standard Confined Space Gases
0
±
0
±
±
(CH4, std)
- 100% LEL
5% of reading or ± 2% LEL 0 - 5% Vol. (CH4)
50 ppm or
0
±
(CO) 0
±
±
Oxygen (O2)
- 40% Vol.
0.5% O2 Carbon Monoxide
- 500 ppm
5% of reading or
0
±
Hydrogen Sulfide (H2S)
- 100 ppm
5% of reading or ± 2
0
±
0
0
0
0
0
Dioxide (CO2) 0
0
0
±
0
0
PID
Dioxide (SO2)
Carbon
- 10,000 ppm
- 5% Vol.
- 60% Vol.
5% of reading or ± 2% of full scale Methane (CH4)
Hydrocarbons
0
0
(CH
) 0 -
4
100% Vol.
Hydrogen (H2) 0 -
0 -
± 5% of reading or ± 2% of full scale
10% Vol.
100% Vol.
Hydrogen (H2) 0 -
0
±
±
100% LEL
- 40,000 ppm
5% of reading or
2% of full scale

The World’s Smallest & Lightest Personal VOC Detector

Cub Personal VOC Detector

The Cub personal PID monitor accurately detects volatile organic (VOC) and total aromatic compounds (TAC). With market leading parts-per-billion (ppb) sensitivity, Cub gives an early warning of hazardous gases, including benzene, before they reach levels which are harmful. Also available is the CubTAC ppm variant with 10.0 eV lamp for the detection of total aromatic compounds (TACs), including benzene.

Features

• Available in three distinct variants: ppm, ppb and TAC mode

• ppm or ppb Cub detects a wide range of over 480 VOCs

• CubTAC detects total aromatic compounds (TACs) down to ppb levels

• Detection range:

• Cub ppm model: 0.1 - 5,000 ppm

• Cub ppb model: 1 ppb - 5,000 ppm

• CubTAC model: 10 ppb - 5,000 ppm

• Optional software upgrade from ppm to ppb

• Lamp:

• Cub ppm & ppb model: 10.6 eV

• CubTAC model: 10.0 eV

• Humidity resistance technology

• Data logging 30,000 readings

• Multi-logging including full list of gases selectable from PC software

• LED audio & vibrate alarm

• Pre-programmed TWA & STEL alarm* (only available for ppb model)

• Work exposure alarm levels

• Three CUBDoc docking stations available:

• Charge dock only

• Charge and USB communication dock

• Charge, USB communication and calibration dock

• Certifications: ATEX, IECEx, CSA - Intrinsically Safe

Applications

• Industrial hygiene

• Chemical and petrochemical plants

• Oil & gas

• Pharmaceuticals

• Health & safety

• Hazardous materials

• First response

• Environmental

Kit Includes

• Cub instrument

• Docking station

• Accessory kit

• Stack removal tool

• Mains cable

• USB cable

• Remote calibration adaptor

• Li-Ion rechargeable battery

• Quick start guide

• Calibration certificate

AIR MONITORING 60 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM

• NLB-H1055100PA**

• NLB-414 or

• NLB-H1055100PA**

*

61 AIR MONITORING AIR MONITORING Part Number Description IS-CUBUPG-M2B Cub Software Upgrade From PPM To PPB IS-LA4TM600 10.6 eV PID Lamp IS-LA4TS600 10.0 eV PID Lamp IS-A-846267 White Fence Electrode Stack IS-A-846417 White With Gold Spot Fence Electrode Stack IS-871026 PTFE Filter Membrane, Each IS-A-31063 PID Lamp Cleaning Kit IS-871200 Calibration Cup NLB-H1055100PA Calibration Gas 100 PPM Isobutylene In Air, 34 Liter Steel Cylinder With CGA 600 NLB-H105510PA Calibration Gas 10 PPM Isobutylene In Air, 34 Liter Steel Cylinder With CGA 600 NLB-Z11145PA Calibration Gas 5 PPM Benzene In Air, 58 Liter Aluminum Cyl. With CGA C-10 NLB-414 0.3 LPM Regulator With Gauge & Knob For Cylinders With CGA 600 NLB-417 0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA 600 NLB-514 0.3 LPM Regulator With Gauge & Knob For Cylinders With CGA C-10 NLB-517 0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA C-10 Accessories & Calibration Equipment
Used to calibrate for ppb measurements
Used to calibrate for ppm measurements
**
Part Number Description Detection Range PID Lamp Fence Electrode Calibration Equipment IS-CKPSXCAX-CH Cub PPM With Charge Docking Station Only 0.1 - 5,000 ppm 10.6 eV White Fence Electrode Stack • NLB-H1055100PA • NLB-414 or NLB-417 IS-CKPSXCAX-WD Cub PPM With Charge & USB Communication Docking Station 0.1 - 5,000 ppm 10.6 eV White Fence Electrode Stack • NLB-H1055100PA
AUTHORIZED ION SERVICE CENTER
NLB-414 or NLB-417 IS-CKPSXCAX-WC Cub PPM With Charge, USB Communication & Calibration Docking Station 0.1 - 5,000 ppm 10.6 eV White Fence Electrode Stack • NLB-H1055100PA • NLB-414 or NLB-417 IS-CKBSXCAX-CH Cub PPB With Charge Docking Station Only 1 ppb - 5,000 ppm 10.6 eV White Fence Electrode Stack
NLB-H105510PA*
NLB-417 IS-CKBSXCAX-WD Cub PPB With Charge & USB Communication Docking Station 1 ppb - 5,000 ppm 10.6 eV White Fence Electrode Stack
NLB-H105510PA*
IS-CKBSXCAX-WC Cub PPB With Charge, USB Communication & Calibration Docking Station 1 ppb - 5,000 ppm 10.6 eV White Fence Electrode Stack
NLB-414 or NLB-417
NLB-H105510PA*
NLB-H1055100PA**
NLB-414
NLB-417 IS-CKTSXCAX-CH CubTAC With Charge Docking Station Only 10 ppb - 5,000 ppm 10.0 eV White With Gold Spot Fence Electrode Stack
NLB-Z11145PA
or
NLB-514 or NLB-517 IS-CKTSXCAX-WD CubTAC With Charge & USB Communication Docking Station 10 ppb - 5,000 ppm 10.6 eV White With Gold Spot Fence Electrode Stack
NLB-Z11145PA
NLB-514 or NLB-517 IS-CKTSXCAX-WC CubTAC With Charge, USB Communication & Calibration Docking Station 10 ppb - 5,000 ppm 10.6 eV White With Gold Spot Fence Electrode Stack • NLB-Z11145PA
NLB-514 or NLB-517 *Other accessories also available
AIR MONITORING 62 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM ION Science Tiger XTL 10.6 eV ION Science Tiger XT 10.6 eV ION Science Tiger XT Select 10.0 eV General VOC Detection Range 0.1 ppm - 5,000 ppm 1 ppb - 20,000 ppm 1 ppb - 20,000 ppm General VOC Minimum Resolution 0.1 ppm 1 ppb 1 ppb T90 Response Time (VOCs) <2 seconds <2 seconds <2 seconds Benzene Detection Range X X 0.01 ppm - 200 ppm Benzene Minimum Resolution X X 10 ppb Response Time (Benzene) X X 130 seconds (at 20oC) Lamp Options 10.6 eV 10.6 eV, 11.7 eV 10.0 eV Easy Change PID √ √ √ Internal Gas Table X >750 VOCs >750 VOCs Weight 870 g 870 g 870 g Humidity Handling Fence Electrode Fence Electrode Fence Electrode Audible Alarm 95 dB 95 dB 95 dB Alarm Vibration √ √ √ Rechargeable Battery √ √ √ Rechargeable Battery Charge Time Typically 8 hours Typically 8 hours Typically 8 hours Rechargeable Battery Life Up to 24 hours Up to 24 hours Up to 24 hours IP Rating Designed to IP65 Designed to IP65 Designed to IP65 Warranty 2 years* 5 years* 5 years* Flow Rate ≥220 ml/min ≥220 ml/min ≥220 ml/min Torch / Flashlight √ √ √ Direct USB Connection √ √ √ Start Up Time <1 minute <1 minute <1 minute Multi Language Function √ √ √ Data Logging 80,000 Data Points 120,000 Data Points 120,000 Data Points PPB Sensitivity X √ √ Health & Safety Mode X √ √ Single Log Only √ √ √ Multi Log Only X √ √ Upgradeable from ppm to ppb X √ √ *When you register your instrument online within one month of purchase TIGER XT COMPARISON CHART HANDHELD VOC DETECTOR Inf Z ne AUTHORIZED ION SERVICE CENTER

Low Cost VOC Detection With Market Leading Accuracy

Tiger XTL Handheld VOC Detector

The Tiger XTL accurately detects volatile organic compounds (VOCs) from 0 - 5,000 ppm with a 0.1 ppm minimum sensitivity, has the fastest response time on the market of just two seconds, and is as quick to clear down. Its revolutionary, patented PID sensor technology with humidity resistance and anti-contamination design provide market leading accuracy and run-time.

Applications

• Environmental monitoring

• Soil contamination detection

• VOCs in landfill

• IAQ measuring industrial volatiles

• Health & safety

• Confined space entry

• First response (screening)

• Wing tank entry

• VOC leak detection

• Fumigation gases

• Fugitive emissions

• Medical gases in hospitals

• Fire and Arson Investigation

Features

• Detection range: 0.1 - 5,000 ppm

• Lamp:

• 10.6 eV (standard)

• 10.0 eV and 11.7 eV (optional also available)

• Patented humidity resistance technology to 99% RH – no compensation needed

• Push-to-log data logging stores up to 80,000 data points in up to 128 user selectable zones

• User selectable response factors for direct concentration readout

• Flashing LED & audible alarm

• Selectable vibrating alarm

• Factory calibration mode available

• Certifications: ATEX, IECEx, CSA - Intrinsically Safe

Standard Kit Includes

• Tiger XTL instrument with rubber boot

• PTFE filter disc (dust filter)

• PID lamp cleaning kit

• Removal tool MiniPID stack

• Li-ion rechargeable battery

• Battery charger

• Mains adaptor

• USB cable

• Compact case

Premium Kit Includes

• Tiger XTL instrument with rubber boot

• Lanyard (wrist strap)

• PTFE filter disc (dust filter)

• Carbon zero filter assembly

• PID lamp cleaning kit

• Removal tool MiniPID stack

• Calibration adaptor

• USB cable

• Li-ion rechargeable battery

• Battery charger

• Mains adaptor

• Explorer case

Accessories & Calibration Equipment

*Other accessories also available

63 AIR MONITORING AIR MONITORING
Part Number Description Detection Range PID Lamp Fence Electrode IS-TXLLSLBMR-0000 Tiger XTL With Standard Kit 0.1 - 5,000 ppm 10.6 eV Electrode Stack Orange • NLB-H1055100PA • NLB-414 or NLB-417 IS-TXLLSLBMP-0000 Tiger XTL With Premium Kit 0.1 - 5,000 ppm 10.6 eV Electrode Stack Orange • NLB-H1055100PA • NLB-414 or NLB-417 Part Number Description IS-A-861632 Premium PTFE Filters, 10/Pack NLB-H1055100PA Calibration Gas 100 PPM Isobutylene In Air, 34 Liter Steel Cylinder With CGA 600 NLB-414 0.3 LPM Regulator With Gauge & Knob For Cylinders With CGA 600 NLB-417 0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA 600
AUTHORIZED ION SERVICE CENTER

Handheld Humidity-Resistant VOC Detector

Tiger XT Handheld VOC Detector

The Tiger XT provides a dynamic detection range of 0 - 20,000 parts per million (ppm) with a minimum sensitivity of 0.001 ppm (1 ppb), offering the widest measurement range of any other volatile organic compound (VOC) detector on the market. Its revolutionary, PID sensor technology with humidity resistance and anti-contamination design provide market leading accuracy and run-time.

Applications

• Environmental monitoring

• Soil contamination detection

• VOCs in landfill

• IAQ measuring industrial volatiles

• Leakage in fuel & chemical storage

• Health & safety

• STEL & TWA monitoring

• Confined space entry

• First response (screening)

• Wing tank entry

• VOC leak detection

• Fumigation gases

• Fugitive emissions

• Medical gases in hospitals

• Fire and Arson Investigation

Kit Includes

• Tiger XT instrument (PPM or PPB) with rubber boot

• Lanyard (wrist strap)

• PTFE filter disc (dust filter)

• Carbon zero filter assembly

• PID lamp cleaning kit

• Removal tool MiniPID stack

Features

• Available in two distinct variants: ppm and ppb

• Detection range:

• Tiger ppm model: 0.1 - 20,000 ppm

• Tiger ppb model: 1 ppb - 20,000 ppm

• Optional software upgrade from ppm to ppb

• Lamp:

• Tiger ppm and Tiger ppb models: 10.6 eV (standard)

• 10.0 eV and 11.7 eV (optional also available)

• Patented humidity resistance technology to 99% RH – no compensation needed

• Push-to-log and multi-logging stores up to 120,000 data points including date/time

• Internal gas table with over 700 VOCs and toxic compounds

• Flashing LED & audible alarm

• Selectable vibrating alarm

• Pre-programmed TWA & STEL alarm* (only available for ppb model)

• Factory calibration mode available

• Certifications: ATEX, IECEx, CSA - Intrinsically Safe

• Calibration Adaptor

• USB cable

• Li-ion rechargeable battery

• Battery charger

• Mains adaptor

• Explorer case

*

AIR MONITORING 64 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM
Part Number Description Model Detection Range PID Lamp Fence Electrode Calibration Equipment IS-TXXXSLBMP-0005 Tiger XT PPM/H&S/ Data Logging PPM 0.1 - 20,000 ppm 10.6 eV Electrode Stack White • NLB-H1055100PA • NLB-414 or NLB-417 IS-TXXESLBMP-0005 Tiger XT PPM/H&S/ Data Logging PPM 0.1 - 20,000 ppm 11.7 eV Electrode Stack White • NLB-H1055100PA
NLB-414 or NLB-417 IS-TXXXSLBMP-0007 Tiger XT PPB/H&S/ Data Logging PPB 1 ppb - 20,000 ppm 10.6 eV Electrode Stack White • NLB-H105510PA* • NLB-H1055100PA**
NLB-414 or NLB-417 Part Number Description IS-A-861632 Premium PTFE Filters, 10/Pack NLB-H105510PA Calibration Gas 10 PPM Isobutylene In Air, 34 Liter Steel Cylinder With CGA 600 NLB-H1055100PA Calibration Gas 100 PPM Isobutylene In Air, 34 Liter Steel Cylinder With CGA 600 NLB-414 0.3 LPM Regulator With Gauge & Knob For Cylinders With CGA 600 NLB-417 0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA 600 Accessories & Calibration Equipment
accessories also available
*Other
Used to calibrate for ppb measurements
Used to calibrate for ppm measurements
**
AUTHORIZED ION SERVICE CENTER

Instant VOC Detection For Fire & Arson Investigation

Tiger XTL & Tiger XT Handheld VOC Detector With Fire Investigation Kit

The Tiger XTL & Tiger XT PID has been specifically designed to provide you with all the tools for a convenient, easy-to-use solution for the detection of volatile organic compounds (VOCs) within fire and arson investigation applications. Both models incorporate Ion Science’s market-leading PID technology with patented fence electrode system. The advanced three-electrode format ensures increased resistance to humidity and contamination for ultimate reliability and accuracy in the field, as well as reduced drift issues and extended run time.

65 AIR MONITORING AIR MONITORING
Part Number Description Detection Range PID Lamp Fence Electrode Calibration Equipment IS-TXLLSRBMP-0000 Tiger XTL With Fire Investigation Kit 0.1 - 5,000 ppm 10.6 eV Electrode Stack Orange • NLB-H1055100PA • NLB-414 or NLB-417 IS-TXXXSRBMP-0004 Tiger XT PPM/Data Logging With Fire Investigation Kit 0.1 - 20,000 ppm 10.6 eV Electrode Stack White • NLB-H1055100PA • NLB-414 or NLB-417 IS-TXXXSRBMP-0006 Tiger XT PPB/Data Logging With Fire Investigation Kit 1 ppb - 20,000 ppm 10.6 eV Electrode Stack White • NLB-H105510PA* • NLB-H1055100PA** • NLB-414 or NLB-417 *Other accessories also available Part Number Description IS-A-861632 Premium PTFE Filters, 10/Pack NLB-H105510PA Calibration Gas 10 PPM Isobutylene In Air, 103 Liter Aluminum Cylinder With CGA C-10 NLB-H1055100PA Calibration Gas 100 PPM Isobutylene In Air, 103 Liter Aluminum Cylinder With CGA C-10 NLB-414 0.3 LPM Regulator With Gauge & Knob For Cylinders With CGA 600 NLB-417 0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA 600 Accessories & Calibration Equipment * Used to calibrate for ppb measurements ** Used to calibrate for ppm measurements Kit Includes • Tiger XTL or Tiger XT instrument with rubber boot
1 m flexi-probe
Bump test pen • Exhaust barb which can be connected to a collection bag
(10) PTFE filters
"AA" Tiger XTL or Tiger XT battery pack for emergency power source
Charging cradle & travel charge adaptor
Mains adaptor
USB cable
Quick start guide
Rugged case
AUTHORIZED ION SERVICE CENTER

Benzene & Total Aromatic Compound (TAC) Detection In One Instrument

Tiger XT Select Benzene & TAC VOC Detector

The Tiger XT Select is a revolutionary hand-held gas detector for the rapid, accurate detection of benzene and Total Aromatic Compounds (TACs). Utilizing the high output Ion Science 10.0 eV detection system, a reading for TACs is seen immediately on start-up. Should aromatics be detected, an ION Science benzene pre-filter tube can be easily attached to ensure fast detection and selective measurement of benzene. Its revolutionary, PID sensor technology with humidity resistance and anti-contamination design provide market leading accuracy and run-time.

Applications

• Confined space entry

• Pre-screening during refinery and plant maintenance

• Marine spill response

• Refinery down-stream monitoring

• Hazardous material response

• Total aromatic compounds (TACs)

• Detection at loading docks and barge operations

Features

• Available in two distinct variants: ppm and ppb

• Selectively detects benzene with benzene pre-filter tubes

• Detection range:

• Tiger Select ppm model: 0.1 - 20,000 ppm

AUTHORIZED ION SERVICE CENTER

(standard mode: 0.1 - 20,000 ppm, TAC mode: 0.01 - 20,000 ppm and tube mode: 0.001 - 200 ppm)

• Tiger ppb model: 0.001 - 20,000 ppm

(standard mode: 0.001 - 20,000 ppm TAC mode: 0.001 - 20,000 ppm and tube mode: 0.001 - 200 ppm)

• Three available modes to choose from: basic mode, advanced mode and ask mode

• Optional software upgrade from ppm to ppb

• Lamp: 10.0 eV

• A 10.6 eV lamp can easily be installed for the detection of a wide range of VOCs

• Patented humidity resistance technology to 99% RH – no compensation needed

• Push-to-log and multi-logging stores > 120,000 data points including date/time

• Internal gas table with over 700 VOCs and toxic compounds

• Flashing LEDs "amber" (low alarm) and "red" (high alarm)

• Audible sounder vibration on alarm

• Pre-programmed TWA & STEL alarm* (only available for ppb model)

• Factory calibration mode available

• Certifications: ATEX, IECEx, CSA - Intrinsically Safe

RAPIDLY

AIR MONITORING 66 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM
DETECTS BENZENE & TOTAL AROMATIC COMPOUNDS (TACs) PROVIDING THE MOST ACCURATE, RELIABLE DATA AVAILABLE.

Kit Includes

• Tiger XT Select instrument (PPM or PPB) with rubber boot

• Lanyard (wrist strap)

• Benzene pre-filter tube probe

• (10) Ion Science benzene pre-filter tubes

• Draeger benzene pre-filter tube opener

• Spare o-ring for tube holder

• PTFE filter disc (dust filter)

• Carbon zero filter assembly

• PID lamp cleaning kit

• Removal tool MiniPID stack

• Calibration adaptor

• USB cable

• Li-ion rechargeable battery

• Battery charger

• Mains adapter

• Explorer case

• NLB-Z11145PA

• NLB-514 or

• NLB-J1055100PA**

• NLB-Z11145PA

• NLB-514 or

*

**Used

*Other

67 AIR MONITORING AIR MONITORING Part Number Description IS-A-861632 Premium PTFE Filters, 10/Pack NLB-H105510PA Calibration Gas 10 PPM Isobutylene In Air, 103 Liter Aluminum Cylinder With CGA C-10 NLB-H1055100PA Calibration Gas 100 PPM Isobutylene In Air, 103 Liter Aluminum Cylinder With CGA C-10 NLB-Z11145PA Calibration Gas 5 PPM Benzene In Air, 58 Liter Aluminum Cyl. With CGA C-10 NLB-514 0.3 LPM Regulator With Gauge & Knob For Cylinders With CGA C-10 NLB-517 0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA C-10 Accessories & Calibration Equipment
accessories also available Part Number Description Model Detection Range PID Lamp Fence Electrode Calibration Equipment IS-TXSXSLBMP-0517 Tiger XT Select Benzene & TAC PPM/ H&S/Data Logging PPM 0.1 - 20,000 ppm 10.0 eV Electrode Stack White + Gold • NLB-J1055100PA
NLB-517 IS-TXSXSLBMP-0519 Tiger XT Select Benzene & TAC PPB/ H&S/Data Logging PPB 1 ppb - 20,000 ppm 10.0 eV Electrode Stack White + Gold • NLB-J105510PA*
NLB-517
Used to calibrate for ppb measurements
to calibrate for ppm measurements AUTHORIZED ION SERVICE CENTER
AIR MONITORING 68 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM Also Available... Fixed Systems Specialty Portable Monitors Detector Heads Beacon 110 Direct Conect Beacon 200 04 Series S2 Beacon 410A EC-600 M2A Beacon 800 Beacon 800 RX-8000 GD-70D EC-600 OX-600
69 AIR MONITORING AIR MONITORING YOUR ONE SHOP Leak Detectors Mercury Vapor Detector VOC Detectors Falco Diffused The Panther MVI SF6 Leakmate Falco Pumped TVOC2 Titan 2 Fixed Systems Buy Rent Calibrate Repair

Odour Destroyer & Neutralizer

Aquakem™ Odour Skunk™

Odour SkunkTM is a plant-based product that eliminates nasty odours at the source. While many products only mask offensive odours with strong fragrances, Odour SkunkTM will neutralize them.

Applications

• Residential

• Commercial

• Industrial

• Wastewater

• Chemical odor control

• Food processing

• Sports

• And many more…

Features

• Captures and neutralizes odours

• Non-toxic

• Biodegradable

• Non irritating

• Available without fragrance (minimum quantities required)

Removal Of Odours, Gaseous Or VOC Particulates

Sampson™ Odour Removal Pleated Air Filters

Sampson™ odour removal carbon pleated filters are designed for the control of intermittent odour problems. This filter can also be a low cost method to verify the potential effectiveness of carbon for controlling an odor problem.

Applications

• Office buildings

• Hospitals

• Airports

• Food courts

• Manufacturing facilities

Features

• Wide range of configurations and sizes available

• Available in 1", 2" and 4" depths

• MERV 5, 6

• Carbon enhanced pleated filter for odor removal

• Can be easily adapted to existing HVAC systems

Cannabis Odour Control Media

CannaSorber™

ERE’s special blend air phase media specifically designed to treat odours from cannabis.

Applications

• Curing/drying rooms

• Cutting/deflowering rooms

• Extraction and packaging rooms

Features

• Proprietary blend of selective media for odour and VOC

• Adsorbs terpenoids

• Adsorbs terpenes

• Adsorbs VOCs

• Has a capacity of up to 60% of its own weight

• Particle size: 4 x 8 US mesh

• CCl4 activity min. (ASTM D-3467): 60

• Proprietary blend active ingredient, % wt. min.: 6.0

• Bulk Density lb/ft3: 39

• Bacteria mold controlled media

AIR ODOUR CONTROL 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM 70
Part Number Description Format Size 10610-500ML Aquakem™ Odour Skunk™ Bottle 500 ml 10610-1L Aquakem™ Odour Skunk™ Bottle 1 L 10610-3.6L Aquakem™ Odour Skunk™ Bottle 3.6 L 10610-20L Aquakem™ Odour Skunk™ Pail 20 L 10610-204L Aquakem™ Odour Skunk™ Drum 204 L 10610-1000L Aquakem™ Odour Skunk™ Tote 1000 L Part Number Description Quantity BCS-408-CANNA CannaSorberTM 40 lbs Bag/Container Part Number Description Nominal Size Actual Size Qty/Box DF-15840 SampsonTM Odour Removal Pleated Air Filter 20" H x 20" W x 1" D 19 ½" H x 19 ½" W x ¾" D 12 DF-15848 SampsonTM Odour Removal Pleated Air Filter 20" H x 20" W x 2" D 19 ½" H x 19 ½" W x 1 ¾" D 12 DF-17081 SampsonTM Odour Removal Pleated Air Filter 20" H x 20" W x 4" D 19 ½" H x 19 ½" W x 3 ¾" D 12 *Other sizes also available

SampsonTM HVAC Pleated Filters

Features

• High Capacity (MERV 10)

• Available in 1”, 2” & 4” depths

• 100% synthetic pleated media achieves exceptionally high levels of efficiency

• Does not rely on electrostatic charge

• Low resistance to air flow means minimal energy costs

• Moisture resistant and will not promote microbial growth

• Excellent pre-filter for higher efficiency air filters

• Effectively removes airborne irritants

• Protects cooling coils & ductwork of HVAC system

Applications

• Prefilter for high efficiency filters

• Office and retail

• Manufacturing and distribution

• Government and education facilities

• Doctor offices, assisted living facilities and hospitals

• Hotels and airports

• Single and multi-family housing

Inf Z ne

AIR FILTRATION/TREATMENT AIR FILTRATION/TREATMENT 71
Part Number Description Nominal Size Actual Size Qty/Box DF-10438 SampsonTM HVAC Pleated Air Filter 12" H x 20" W x 1" D 11 ½" H x 19 ½" W x ¾" D 12 DF-10447 SampsonTM HVAC Pleated Air Filter 20" H x 20" W x 1" D 19 ½" H x 19 ½" W x ¾" D 12 DF-10489 SampsonTM HVAC Pleated Air Filter 20" H x 24" W x 1" D 19 ½" H x 23 ½" W x ¾" D 12 DF-10448 SampsonTM HVAC Pleated Air Filter 20" H x 25" W x 1" D 19 ½" H x 24 ½" W x ¾" D 12 DF-10456 SampsonTM HVAC Pleated Air Filter 16" H x 20" W x 2" D 15 ½" H x 19 ½" W x 1 ¾" D 12 DF-10460 SampsonTM HVAC Pleated Air Filter 20" H x 20" W x 2" D 19 ½" H x 19 ½" W x 1 ¾" D 12 DF-10462 SampsonTM HVAC Pleated Air Filter 20" H x 25" W x 2" D 19 ½" H x 24 ½" W x 1 ¾" D 12 DF-10463 SampsonTM HVAC Pleated Air Filter 24" H x 24" W x 2" D 23 ⅜" H x 23 ⅜" W x 1 ¾" D 12 DF-10466 SampsonTM HVAC Pleated Air Filter 16" H x 20" W x 4" D 5 ½" H x 19 ½" W x 3 ¾" D 6 DF-10467 SampsonTM HVAC Pleated Air Filter 16" H x 25" W x 4" D 15 ½" H x 24 ½" W x 3 ¾" D 6 DF-10469 SampsonTM HVAC Pleated Air Filter 20" H x 20" W x 4" D 19 ½" H x 19 ½" W x 3 ¾" D 6 DF-10471 SampsonTM HVAC Pleated Air Filter 20" H x 25" W x 4" D 19 ½" H x 24 ½" W x 3 ¾" D 6 * Contact customer service for additional sizes and information Available Air Filters For Many Applications • Commercial / Industrial • Health Care / Government Facilities • Schools / Universities • Aerospace • Hospitals • Cleanrooms • Food manufacturing • Chemical • Pharmaceutical • Laboratories • Hotels • Desert / Marine Installations

UltraSorber-BCTM

The UltraSorber-BCTM activated carbon manufactured from selected grades of bituminous coal ideally suited for VOC gas adsorption. possesses both a high surface area and a large internal pore volume. These properties give the carbon not only high VOC adsorption capacities, but also highly retentive for retaining and preventing the desorption of previously adsorbed organic compounds. Being manufactured from high rank coals results in an inherently low ash content, making these carbons ideally suited for critical gas phase adsorption applications.

Features

• Specifically manufactured from select grades of bituminous coal

• Excellent for applications from general odour abatement to solvent adsorption and recovery

• High surface area and broad pore structure

• Less frequent changeouts = cost effective

• Lower pressure drops

• Packaged in bags, totes, and super sacs

Applications

• Solvent recovery operations

• Chemical process applications

• VOC control from air strippers, soil vapor extraction and air sparge systems

• Control of tank vent emissions

• HVAC

• Odor control

• As a substrate for odor control carbon manufacture and as a catalyst support

UltraSorber-CNSTM

The UltraSorber-CNSTM is a high activity, granular activated carbon manufactured from selected grades of coconut shell. The granular shape of this carbon maximizes its geometric surface area, significantly increasing surface and pore diffusion rates and thereby increasing its effectiveness for the adsorption of VOCs with a short contact time. The high surface area and predominately microporous pore size distribution further enhance the effectiveness of this coconut shell based carbon.

Features

• Specifically manufactured from coconut shells

• Long life expectancy and removal efficiency

• Excellent hardness

• High surface area and micropore structure

• Less carbon changeouts, less dust and fines

• High adsorption capacity, lower pre-soak times, readily wettable

• Packaged in bags, totes, and super sacs

Applications

• Chemical process applications

• VOC control from air strippers, soil vapor extraction and air sparge systems

• Control of tank vent emissions

• HVAC

• Odor control

• Solvent recovery of low boiling point solvents

• Use as a catalyst/catalyst support

AIR FILTRATION/TREATMENT 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM 72
Part Number Mesh CCl4 Density Hardness Ash Iodine Surface Area BC-410 4 x 10 60% 0.40 - 0.46 g/cc 90 - 94% 6 - 10% 1000 mg/g 1000 - 1100 m2/g BC-406 4 x 6 60 - 65% 0.44 - 0.49 g/cc 95% 8 - 10% 1000 mg/g 1150 m2/g BC-608 6 x 8 62 - 67% 0.48-0.52 g/cc 95 - 97% 8 - 10% 1000 mg/g 1100 - 1200 m2/g BC-710 7 x 10 62 - 72% 0.44 - 0.52 g/cc 95 - 97% 8 - 10% 1000 - 1050 mg/g 1100 - 1250 m2/g Part Number Mesh CCl4 Density Hardness Ash Iodine Surface Area CNS-612 6 x 12 60 - 65% 0.48 - 0.55 g/cc 96 - 98% 5% 1100 - 1200 mg/g 1150 - 1250 m2/g CNS-185 4 x 8 55% 0.48 - 0.54 g/cc 90 - 95% 2.5% 1050 mg/g 1100 - 1250 m2/g

UltraSorberTM AMMO-CarbTM

UltraSorberTM AMMO-CarbTM is coal based activated carbon in pelletized or extruded form. The amount of phosphoric impregnation shall be no less than 7% by weight on the media. UltraSorberTM AMMO-CarbTM is designed for vapor phase applications.

UltraSorberTM KOH-CarbTM

Features

• High quality carbon

• Extraordinary surface area

• Fine pore structure

• High density

• Superior hardness

• Sold in bags, drums, and super sacs

Applications

• Paper industry

• Food industry

• Biogas industry

• Process and wastewater treatment industry

Contaminants Removed

• Ammonia

• Urea

The UltrasorberTM KOH-CarbTM is highly active coal based pelletized carbon impregnated with potassium hydroxide. The coal based activated carbon is manufactured for vapor phase applications.

Features

• Hydrogen sulfide removal capacity of 0.10 g/cc

• Impregnated with potassium hydroxide to target acidic gases

• Carbon tetrachloride activity of no less than 60%

• Sold in bags, drums, and super sacs

Applications

• Chemical processing

• Air stripper off-gas VOC removal

• Tank or sump air vents

• General HVAC units

• API separator vents

Contaminants Removed

• Hydrogen Sulfide

• Sulfur Dioxide

• Nitrogen Oxide

UltraSorberTM VPP-CarbTM

The UltraSorberTM VPP-CarbTM uses reactive chemistry to oxidize various pollutants. The UltrasorberTM VPP-Carb is zeolite impregnated with 6% potassium permanganate (KMnO4). Its’ high impregnated level of KMnO4 and insignificant dusting attributes make it an ideal media for gas phase filtration. The media is loaded in tanks, exhaust systems, soil vapor extraction (SVE) systems, air filtration trays and modules.

Features

• Sold in bags, drums, and super sacs

Applications

• Fresh fruit and vegetable transportation

• Refineries

• Pulp and paper mills

• Ground water remediation

• Wastewater treatment

Contaminants Removed

• Dichloroethylene (DCE)

• Trichloroethylene (TCE)

• Hydrogen Sulfide

• Mercaptans

• Acid gases

• Vinyl Chloride

• Common odors

• Aldehydes

• Ethylene

• Amines

• Chlorinated solvents

AIR FILTRATION/TREATMENT AIR FILTRATION/TREATMENT 73
Part Number Mesh Density Hardness Iodine Moisture AMMO-Carb 4 mm 36-38 lb/ft3 98 % 1100 – 1200 mg/gm 3 % Part Number Mesh CCI4 Density Hardness Pressure Drop KOH-Carb 4 mm 60 % 0.56-0.58 g/cc 95% 1.5 @ velocity 60 ft/min-ins wg/ft Part Number Mesh Density Hardness VPP-Carb 4 x 6 60-62 lb/ft3 95%

UltraSorberTM MER-CarbTM

The UltraSorberTM MER-CarbTM is highly active sulfurized granular activated carbon (GAC) manufactured via high temperature steam activation from selected grades of coconut shell. The MerCarbTM is used in vapor phase applications.

UltraSorberTM Voc-CarbTM

Features

• Impregnated with 10% sulfur content by weight

• Can be loaded in tanks, exhaust systems, general HVAC systems, deep bed scrubbers, etc.

• Sold in bags, drums, and super sacs

Applications

• Manufacturing facilities

• Semiconductor facilities

• Refineries

Contaminants Removed

• Mercury

The UltraSorberTM Voc-CarbTM is a blend of UltraSorber-BCTM & VPP-CarbTM and is commonly used to remove volatile organic compounds (VOC) from vapor/gas phase. The two products blended together casts a wide net to remove a handful of inorganic and organic compounds.

Features

• (GAC) manufactured via high temperature steam activation from selected grades of coconut shell

• VPP-CarbTM its high impregnated level of potassium permanganate and insignificant dusting attributes make it an ideal media

• Potassium permanganate impregnated, 6 % wt. min.

• Sold in bags, drums, and super sacs

Applications

• Air dryers

• Scrubber tanks

• Exhaust systems

• Airports computer rooms

• Trays, modules, air filtration housings

• HVAC

Contaminants Removed

• BTEX

• Acid gases

• Chlorinated solvent

• Diesel fume

• Asphalt fume

• Butadiene

• Smoke

UltraSorberTM CannaSorbTM

The UltraSorberTM CannaSorbTM is a proprietary blend of selective media for odor and volatile organic compounds (VOC) removal. This media is successful at removing terpenoids and terpenes from vapor phase. Terpenoids and terpenes are large organic compounds produced by cannabis plants. The UltraSorberTM CannaSorbTM is commonly found in the final product handling rooms such as the curing/drying, cutting/deflowering, extraction, and packaging rooms. At the final product handling rooms the odors described as floral, fruity, pungent, or even skunky are strongest.

Features

• Does not promote bacterial or mold growth

• Designed specifically for cannabis grow houses, but can be used in indoor cultivation facilities.

• Sold one cubic foot boxes (33 lbs/box), drums, or supersacks

Applications

• Curing/drying rooms

• Cutting/deflowering rooms

• Extraction and packaging rooms

Contaminants Removed

• Terpenoids

• Terpenes

• Limonene

• Pinene

• Fertilizer VOC

AIR FILTRATION/TREATMENT 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM 74
Part Number Mesh Density Hardness Iodine Ash MER-Carb 4 x 10 36-38 lb/ft3 95% 1000 – 1050 mg/g 8-10% Part Number Mesh CCI4 Density Hardness VOC-Carb 4 x 8 60 44.46 lb/ft3 95% Part Number Mesh CCI4 Density Hardness CannaSorb 4 x 8 60 32-34 lb/ft3 95%

UltraVentTM Air Filter

Reversible Activated Carbon Filter

Differential static pressure across filters will cause differential contaminent accumulation in the media. UltraventTM reversible carbon filter is the only filter to offer a solution with the twist lock flange and end cap allowing to reverse the filter and equalize contaminent distribution in the media.

Most cylindrical-type air filters utilize 65% of the carbon available by only filtering through the top section of the carbon filter, leaving the bottom section unused. UltraventTM’s innovative patented design allows reversal of the filter, benefitting of 100% of the carbon available and extending the units' life span. Manufactured with only the finest high porosity activated carbon, UltraventTM effectively removes 99.5% of odors. Rated for a continuous worry-free operation and available in many different sizes and CFM ratings, UltraventTM filter can be used for industrial, commercial or residential applications.

Features

• Rubber gasket to ensure air tight fitting

• Twist lock Flange. No tools required

• Parts made of high impact resistant polycarbonate

• High quality galvanized steel

• High capacity prefilter:

- 20mm thickness

- Low air resistance

- Antibacterial

- High capacity: 670g /m2

- Flame retardant

• High porosity virgin extruded activated carbon 4mm. Specially designed to remove VOC. 66mm bed thickness

• Convenient elastic band easing installation of the prefilter

• Twist lock end cap. No tools required

UltraSorber-Air™-500

Features

• Maximum Flow: 500 cfm

• Carbon Weight: 2000 lbs

• System Pressure Drop: 19" wc

• Dimensions: 88" H x 46" W

• Capacity: 500 Gallons

• Weight: 650 lbs (Tank) + Media

Applications

• Emissions from industrial plants

• Refinery and chemical plant wastewater

• Soil vapor extraction

• BioVenting

• Emissions from waste processing operations

• Air stripper off-gas VOC removal

• API separator vents

• Waste water and product storage tank vents

• Emergency air quality control

• ACI systems for mercury reduction

• Lift stations

• Industrial odor

• Air treatment

Contaminants Removed

• VOC

• Hydrogen sulfide

• Sulfur dioxide

• Formaldehyde

• Ethylene

• Mercaptans

• Various aldehydes

• Alcohols

• Carbon dioxide

• Nitrogen

• Mercury

• Solvents

AIR FILTRATION/TREATMENT AIR FILTRATION/TREATMENT 75
Part Number Recommended Flange Outside Diameter Height Weight Carbon Bed Width Recommended Fan Pressure Drop at Max CFM UltraventTM 450 ER-450@0.1 sec 6" 15.4" 20" (50 cm) 52.4 lbs 2.6" (66 mm) V600 & S600 180 pa/.75wg UltraventTM 650 ER-650@0.1 sec 6" 15.4" 30" (75 cm) 730 lbs 2.6" (66 mm) V600 -V800 & S600 & S800 180 pa/.75wg UltraventTM 900 ER-900@0.1 sec 6" or 8" 15.4" 40" (100 cm) 100.0 lbs 2.6" (66 mm) V600 - V1000 & S600 - S1000 180 pa/.75wg UltraventTM 1150 ER-1150@0.1 sec 8" or 10" 15.4" 50" (125 cm) 124.6 lbs 2.6" (66 mm) V600 & S600 180 pa/.75wg UltraventTM 1300 ER-1300@0.1 sec 10" or 12" 15.4" 60" (150 cm) 152.2 lb 2.6" (66 mm) V1000 - V1200 & S1000 180 pa/.75wg
Part Number Max Flow Carbon Weight System Pressure Drop Dimensions Capacity Weight UltraSorber-Air™-500 500 cfm 2000 lbs 19" wc 88" H x 46" W 500 Gallons 650 lbs (Tank) + Media
Rent
Available To

VOC & Odour Control Ventilator System

UltraVent™ is an effective and easily transportable air purification system for quick response specifically designed to treat toxic vapors, irritant and corrosive gases and other noxious odors in emergency, temporary or fixed situations which uses granular activated carbon to remove organic contaminants from an air stream. UltraVent™ system is easily portable and can be delivered and installed in hours at your facility or site.

Includes

• Metal drum with carbon

• Top mounted blower

• Start Switch with Internal thermal overload protection

• 15 Feet of SOW cable and standard plug

• Dolly with casters for ease of transportation

UltraSorberTM-Air Treatment Units

What Is Your Contaminant?

ERE manufactures the UltraSorberTM Air treatment units for many different types of applications. From industrial to commercial applications. Also available in different sizes. Each unit is specifically designed for each application.

AIR FILTRATION/TREATMENT 1-888-287-3732 | EREINC.COM | SALES@EREINC.COM 76 Drum Size Liquid Loading Rate Time Residence Inlet & Outlet 5 gal. (Plastic) 36.7 cfm @ 20 cfm 1.9 Sec @ 20 cfm 1" FNPT 10 gal. (Plastic) 36.59 cfm @ 45 cfm 1.64 Sec @ 45 cfm 1 1/4" FNPT 25 gal. (Plastic) 42.08 cfm @ 85 cfm 3.09 Sec @ 85 cfm 2" FNPT 55 gal. (Metal or Plastic) 54.35 cfm @ 150 cfm 3.21 Sec. @ 150 cfm 2" FNPT 85 gal. (Metal) 82.87 cfm @ 300 cfm 2.08 Sec. @ 300 cfm 4" FNPT 250 gal. (Plastic) 60 cfm @ 600 cfm 2.67 sec @ 600 cfm 4" Slip / 6" Slip
Part Number Max Flow Motor Dimensions Approx. Weight Bottom Inlet Top Outlet CARB-1071001-45G170 200 cfm @ 5" SP 1/2 hp, 115V/1/60 34" W x 23" H 275 lbs 2" FNPT 4" O.D. Slip CARB-1071001-85G310 375 cfm 1 hp, 115V/1/60 40" W x 28" H 400 lbs 4" FNPT 5" O.D. Slip *Tubing not included
UltraVentTM-OD
Available To Rent

UltraSorber-CHLOROTM, Chlorine & Acidic Gas Removal

Coal impreg. Potassium Hydroxide

UltraSorber-BCTM, General Contaminants of low and High Mol Weight Removal

UltraSorber-ODORTM, Sewage Odour Control - H2S or Sulphur Compounds Removal

UltraSorber-FUMETM, Used with Fume Hoods Media:

UltraSorber-FORMATM, Removes Alcohols, Aldehydes, Amines, Ethylene, Formaldehyde, Mercaptans, Organicacids, Oxides, Sulfur compounds (H2S, SO2, etc.), vinyl chloride, etc

UltraSorber-ALCOTM, Removes Alcohols, Aldehydes, Amines, Ethylene, Formaldehyde, Mercaptans, Organic acids, Oxides, Sulfur compounds (H2S, SO2, SOx etc.), vinyl chloride, etc. Media: Zeolite Impreg. with Potassium Permanganate Mixed with Coconut Shell

When considering activated carbon for air filtration, several factors needs to be taken into account:

• Adsorbate type and concentration

• Oxidation/reaction potential for adsorbed compounds (most commonly associated with ketones)

• Air temperature

• Relative humidity of the air stream (RH levels in excess of 50% can lead to excessive moisture adsorption onto the carbon, impacting contaminant removal)

AIR FILTRATION/TREATMENT AIR FILTRATION/TREATMENT 77
Inf Z ne
Part Number Drum Size Drum Material Bulk Density Mesh Size Approx. Media Weight Flow Rate Max Pressure UltraSorber-AmmoTM, Ammonia Removal Media: Anthracite Coal impreg. Phosphoric Acid 90-015-55M 55 gal Metal 35 lbs/cf 6 x 8 210 lbs 150 cfm 8 psi 90-015-85M 85 gal 315 lbs 375 cfm 3 psi
Media: Anthracite
90-016-55M 55 gal Metal 36 lbs/cf 4 x 6 216 lbs 150 cfm 8 psi 90-016-85M 85 gal 324 lbs 375 cfm 3 psi UltraSorber-MistTM, Oil Mist Removal Media: Bituminous Coal Based Carbon 90-017-55M 55 gal Metal 45 lbs/cf 4 x 16 270 lbs 150 cfm 8 psi 90-017-85M 85 gal 405 lbs 375 cfm 3 psi
Media: Bituminous
Carbo 90-018-55M 55 gal Metal 30 lbs/cf 4 x 10 180 lbs 50 cfm 8 psi 90-018-85M 85 gal 270 lbs 375 cfm 3 psi UltraSorber-CSTM, Trace Contaminants Lower than 80 Mol Weight Removal Media: Carbon Coconut Shell 90-019-55M 55 gal Metal 30 lbs/cf 4 x 8 180 lbs 150 cfm 8 psi 90-019-85M 85 gal 270 lbs 375 cfm 3 psi
Coal Based
Media: Catalytic
90-020-5P 5 gal Plastic 28 lbs/cf 4 x 6 11.2 lbs 25 cfm 1 psi 90-020-10P 10 gal 28 lbs 40 cfm 1 psi 90-020-25P 25 gal 84 lbs 85 cfm 1 psi 90-020-55P 55 gal 168 lbs 150 cfm 2 psi 90-020-250P 250 gal 880 lbs 600 cfm 1 psi
Activated Bituminous Coal Based Carbon
90-021-55M 55 gal Metal 36 lbs/cf 4 x 6 216 lbs 150 cfm 8 psi 90-021-85M 85 gal 324 lbs 375 cfm 3 psi
Media: Bituminous Coal Based Carbon Impreg. Sulphur 90-022-55M 55 gal Metal 34 lbs/cf 4 x 10 204 lbs 150 cfm 8 psi 90-022-85M 85 gal 306 lbs 375 cfm 3 psi
Anthracite Coal Impreg. Potassium Hydroxide and Potassium Iodine
UltraSorber-MERCTM, Mercury Removal
Media: Zeolite
Permanganate 90-023-55M 55 gal Metal 55 lbs/cf 4 x 8 330 lbs 150 cfm 8 psi 90-023-85M 85 gal 495 lbs 375 cfm 3 psi
Impreg. with Potassium
90-024-55M 55 gal Metal 45 lbs/cf 4 x 8 270 lbs 150 cfm 8 psi 90-024-85M 85 gal 405 lbs 375 cfm 3 psi

REPAIR AND CALIBRATION SERVICES

ERE is the Ultimate source in Environmental Equipment. This reputation also demands ultimate service for the equipment. You can rely on ERE’s service department for timely repair and/or calibration of instruments and equipment.

Whether it’s a routine calibration, maintenance or repair, come and join us! The coffee is on us!

RueBombarier Rue Lamarche RueChampd’Eau Parc Lucie-Bruneau Our products are subject to change Discounts available for bulk orders or yearly contracts. Tel: 51 4-326-8852 1-888-287-EREC (3732) Email: sales@ereinc.com Web: www.ereinc.com You can order by phone, fax, email, and internet. Our customer ser vice staf f will be happy to assist you. Register online today and receive our monthly promotions and product updates. OUR STORE 8605 Champ d’Eau Montréal, Quebec, Canada H1P 3B8 Tel: 514-326-8852 • Fax: 514-326-8961 Monday–Friday 8:00 AM to 4:30 PM
V O L . 5 AIR SAMPLING MONITORING FILTRATION TREATMENT V O L . 5
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.