STRUCTURE AND OPERATION • When the boost pressure in chamber A exceeds the predetermined value, the waste gate valve opens, reducing the amount of exhaust gas flowing toward the turbine wheel. As a result, the speed of the compressor wheel and thus the boost pressure are reduced.
3. Muffler • Converter is built into muffler to decrease the amount of particulate matter (PM) in the exhaust gas.
15-4