with magnet 100mesh

Suction strainer

Capacity: 70liters (18.5 US gal.)/min at 2300rpm

Oil pump

Setting: 0.15 to 0.69 MPa (1.53 to 7.0 kgf/cm 2 ) [21.8 to 100 psi]

Torque converter inlet relief valve

Oil cooler

Chassis area

R C 3 C1

Transmission oil reservoir

C2 CF

Lubrication line

Oil filter

Torque converter bypass orifice: Diam. 4.0mm (0.157 in.)

Torque converter

Transmission hydraulic circuit

1

Last chance filter

Orifice: Diam. 0.8 mm(0.031 in.)

Last chance filter

Main orifice: Diam. 2.2 mm(0.087 in.)

2

F

3

R

(marked D)

PD

Orifice: Diam. 0.8 mm(0.031 in.)

Oil filter for forward/ reverse clutches (particle size )

Last chance filter

Solenoid valve (direction selection)

Setting: 0.88 to 1.08 MPa (9.0 to 11.0 kgf/cm ) [127.6 to 145 psi)

Main regulator valve

PM Tap (plug) for main pressure (marked "M")

Tap (plug) for torque converter inlet pressure (marked "T") T/C in

Speed selector valve S1 (1st speed)

(0.031 in.)

Orifice: Diam. 0.8 mm

Speed selector valve S2 (2nd /3rd speed)

Orifice: Diam. 0.8 mm(0.031 in.)

Solenoid valve (direction selection) Last chance filter

PS (marked S)

Setting: 0.2 MPa (2.0kgf/cm 2 ) [29 psi]

Differential valve

Pressure at start of charging 0.3 MPa (3.1kgf/cm 2 )[43.5 psi] Pressure at end of charging 0.76 MPa (7.8kgf/cm 2 )[110 psi]

Accumulator valve

3-SPEED POWERSHIFT TRANSMISSION

2.6 Hydraulic Controls

212196

7-9