54 • Immediately (in less than 5 seconds) after the pinion 3 has started rotating, set the switch C to OFF to stop rotation of the pinion.

DC24V

CAUTION&-------------

A C

®14260

When the switch A and switch Care set to ON, current is supplied to both the pull-in coil P and holding coil H. Since wiring is such that no voltage is applied to terminal B of the starter, current flows to the pull-in coil during rotation of the pinion 3. To prevent baking the pull-in coil, therefore, it is necessary that the switch C is set to OFF immediately (in less than 5 seconds) after the pinion has started rotating.

• Set the pipe-like tool E on the pinion stopper 2. • Lightly strike the tool E with a hammer to remove the stopper ring 1 from the ring groove F of the pinion stopper 2. • Remove the stopper ring 1 and remove the pinion 3. • Set the switch A to OFF to stop supplying current to the starter.

F�

CAUTION&,-------------®10779

3

2

[Installation] To install the pinion 3, it is not necessary to supply current to the starter. • Install the pinion stopper 2 and pinion 3 on the overrunning clutch 32 in the direction shown. • Set the stopper ring 1 in the ring groove F of the overrunning clutch 32.

..

(

'� F

When the power supply to the starter is stopped, the pinion 3 may move in and the stopper ring 1 may fit in the ring groove F of the pinion stopper 2 again. In this case, repeat the operations by supplying current to the starter.

®10781

• Pull the pinion 3 strongly to make sure that the stopper ring 1 securely fits in the ring groove F of the pinion stopper 2.

®10782

54-115