RPV-2 Pulp Rheotek Pulp Viscometer - Dilute Solution Viscosity of pulp & cellulose The RPV-2 is suitable for determining the intrinsic viscosity of pulps and purified celluloses, as well as electrical papers in dilute solution using glass capillary viscometers, in accordance with standard international methods of test. Typical applications include: •

Intrinsic Viscosity – Cellulose – ASTM D1795

Limiting Viscosity Number – pulp – ISO 5351

Average viscometric degree of polymerization – new and aged electrical papers - ASTM D4243, IEC 60450

Viscosity of Pulps – Cellulose solution – Tappi T230

Features •

RPV-2 is ruggedly designed and compatible with most solvents, including cupri-

• • • • • • •

ethylenediamine (CED) solution RPV-2 includes a nitrogen purge module RPV-2 automatically calculates results in accordance with Martin’s formula (LVN) RPV-2 fully complies with a wide range of pulp and cellulose methods RPV-2 can carry out duplicate solution determinations RPV-2 determines precise solution viscosity results RPV-2 includes comprehensive software to report a wide range of results RPV-2 can be integrated with a range of other modules, including sample preparation (including water and CED solution), shakers, reaction stations and sample delivery systems

……making precision routine Subject to PSL’s terms and conditions. Technical changes may apply.

Poulten Selfe & Lee Ltd © 2018


RPV-2 Pulp Configuration The RPV-2 Pulp Analyzer includes the following integrated modules: • • • • • •

viscometer bath, cooling and LED lighting measuring heads with nIR opto-electronic detection PC processor (no external PC required) pressure pumps for raising the sample in the glass viscometer N2 purge module vacuum pumps for drying

PSL Rheotek are the trademarks of Poulten Selfe and Lee, a UK company established in 1850. The Company has a long tradition of developing and manufacturing scientific measuring instruments – primarily for solution viscosity, kinematic viscosity and temperature. The Company is embracing new technology and has a strong development team in the areas of thermal engineering, embedded electronics and robotics. The PSL Calibration Laboratory is accredited in viscometer and temperature calibration. Going forwards, the company is developing a wide range of new products for viscosity and temperature control.

RPV-2 Pulp Specifications Suitable Applications

Reported Results

Flow times modes Temperature stability Temperature set-points No. of cleaning solvents Nitrogen purge Dimensions: (w x L x h) Weight Interfaces External connections Power requirement Power consumption

Diluting pulps, cellulose, new and aged cellulostic electrically insulating materials Viscosity (mPa.s) Relative Viscosity Intrinsic Viscosity (mL/g) Average viscometric degree of polymerization Determinability Max-Min +/- 0.01 or better As required by methods e.g. 20, 25, 30 deg. C 2 (as standard) Optional third solvent Included 395mm x 590mm x 580mm 40 kg RS232, USB, VGA Solvent and waste bottles PC monitor 100 – 240 VAC Max 600W

Ordering Information RPV-2 (1) Pulp RPV-2 (2) Pulp RPV-2 (4) Pulp Options

RPV-2 with one measuring position RPV-2 with two measuring positions RPV-2 dual analyzers with four measuring positions iSP-2 integrated sample preparation, shaker, Sample Delivery

Contact Worldwide: Poulten Selfe & Lee Ltd (UK)

North America: PSL Rheotek USA, Inc – 574 271 9417

Subject to PSL’s terms and conditions. Technical changes may apply.

Poulten Selfe & Lee Ltd © 2018

RPV-2 Pulp Data sheet  

Limiting Viscosity number of pulp. Automated viscometer system for measurement of pulp viscosity.

RPV-2 Pulp Data sheet  

Limiting Viscosity number of pulp. Automated viscometer system for measurement of pulp viscosity.