C
asheville 828.619.0301 rock hill 803.324.5531
D
charleston 843.619.7662
5
contact@vin-yet.com
4
312 Pendleton St. Rock Hill, SC 29730
3
2
vinyet architecture HISTORIC REVIEW
1
This document is an instrument of service and shall remain the property of VinYet Architecture, LLC, who retains all common law, statutory and other reserved rights, including the copyright thereto.
Copyright © 2023 VinYet Architecture, LLC Revision Schedule Rev #
Revision Description
PLAN NORTH
Date
TRUE NORTH
113 E. Main Street Rock Hill, SC 29730
MORTON AND GETTYS ATTORNEYS AT LAW PATIO
EXISTING CONDITIONS
A
A23001
12/8/2023 10:54:04 AM
V:\VYA\Projects\2023\A23001_Morton&Gettys\Revit\A23001_MortonAndGettys - Patio.rvt
B
12.04.23
A007 1
2
3
4
5
C CHANNELCONNECTING PERIMETER C CHANNEL TO WIDE FLANGE, SEE STRUCTURAL
A201
ALL INTERIOR PLAN DIMENSIONS ARE TO FACE OF STUD UNLESS OTHERWISE NOTED.
2.
OPENING DIMENSIONS OF WINDOWS AND DOORS ARE TO CENTERLINE OF MANUFACTURED UNIT UNLESS OTHERWISE NOTED.
3.
CONTRACTOR TO VERIFY ALL ROUGH OPENING DIMENSIONS WITH MANUFACTURED UNIT PRIOR TO FRAMING.
4.
ALL WALLS AND SLABS ARE AT 90° TO EACH OTHER UNLESS OTHERWISE NOTED.
5.
CONTRACTOR SHALL PROVIDE AND INSTALL ALL BLOCKING AND BRACING FOR CASEWORK, ACCESSORIES, ETC. AS REQUIRED.
6.
REFER TO BUILDING ELEVATIONS AND SECTIONS FOR ALL WINDOW/ STOREFRONT HEAD HEIGHTS
7.
REFER TO BUILDING ELEVATIONS FOR ALL EXTERIOR FINISH MATERIALS, COLORS, AND TRIM DETAILS
8.
ALL FF&E TO BE PROVIDED BY THE OWNER AND INSTALLED BY THE CONTRACTOR PER THE MANUFACTURER'S RECCOMENDATIONS.
9.
ALL EXISTING EXTERIOR WALLS TO RECEIVE SPECIFIED SHEATHING, INSULATION REQUIREMENTS SHALL BE COORDINATED WITH WALL TYPES, FLOOR PLANS AND ENERGY CODE SUMMARY AND BE INSTALLED PER THAT SPECIFIED INFORMATION.
10.
ALL DOORS TO BE 4" OFF FACE OF STUD AT HINGE SIDE U.N.O.
11.
PROVIDE WOOD BLOCKING IN PARTITIONS AT ALL LOCATION WHERE WORK SURFACE, SHELVING, BRACKETS, DISPLAYS, GRAB BARS, HANDRAILS AND/OR EQUIPMENT WILL BE MOUNTED OR ATTACHED TO THE FACE OF WALL FOR STRUCTURAL STABILITY. REFERENCE FLOOR PLANS FOR LOCATIONS OF SUCH EQUIPMENT. ALL CONCEALED WOOD SHALL BE FIRE RETARDANT LUMBER AND INSTALLED WITH THE LABEL FACING OUT.
C CHANNEL PERIMETER BEAM PER STRUCTURAL
2
WIDE FLANGE BEAM PER STRUCTURAL
1 A301
A
16'-0"
STEEL HANDRAIL
2'-0"
2'-0"
2'-0"
B
asheville 828.619.0301
D
1.
rock hill 803.324.5531
FLOOR PLAN NOTES:
charleston 843.619.7662
5
contact@vin-yet.com
4
312 Pendleton St. Rock Hill, SC 29730
3
2
vinyet architecture HISTORIC REVIEW
1
C
C EQ
EQ
EQ
This document is an instrument of service and shall remain the property of VinYet Architecture, LLC, who retains all common law, statutory and other reserved rights, including the copyright thereto.
EQ
Copyright © 2023 VinYet Architecture, LLC 2 A301
Revision Schedule Rev #
Revision Description
Date
CONCRETE PAD OVER METAL DECKING PER STRUCTURAL
1
10'-0"
A201
PAINT ALL STEEL BLACK TO MATCH ADJACENT RAILINGS AT YORK COUNTY ARTS COUNCIL
C CHANNEL AS RAILING TOP RAIL
WIDE FLANGE BEAM PER STRUCTURAL
PLAN NORTH
TRUE NORTH
B
FLOOR PLAN
A A23001
2 PATIO FLOOR PLAN A111
12/8/2023 10:54:05 AM
V:\VYA\Projects\2023\A23001_Morton&Gettys\Revit\A23001_MortonAndGettys - Patio.rvt
2'-0"
D
113 E. Main Street Rock Hill, SC 29730
MORTON AND GETTYS ATTORNEYS AT LAW PATIO
WIDE FLANGE COLUMN @ ALL FOUR CORNERS PER STRUCTURAL
12.04.23
3/4" = 1'-0"
A111 1
2
3
4
5
1
3
2
4
5
16'-0"
ALL EXTERIOR EXPOSED STEEL TO BE SHOP-PRIMED WITH SHERWIN WILLIAMS PRO INDUSTRIAL PRO-CRYL UNIVERSAL PRIMER, B66-310 SERIES THEN FINISHED WITH 2 COATS OF SHERWIN WILLIAMS PRO INDUSTRIAL ACRYLIC SEMI-GLOSS, B66-650 SERIES. COLOR TO BE DETERMINED. SUBMIT COATING SPECIFICATIONS AND DRAWDOWN TO ARCHITECT FOR APPROVAL.
4.
REFER TO FINISH SCHEDULE FOR PAINT SPECIFICATIONS.
5.
SEALANT TO BE SIKAFLEX POLYURETHANE SEALANT. COLOR MATCH TO ADJACENT BUILDING SURFACE.
6. 7.
ALL COPING TO BE ATAS RAPID LOCK CONTINUOUS CLEAT COPING - PRE-FINISHED TO MATCH ADJACENT BUILDING MATERIAL UNLESS NOTED OTHERWISE. CEMENTITIOUS LAP SIDING TO BE HORIZONTAL SMOOTH CEMENTITIOUS; W/ 8" EXPOSURE; PNT-02.
8.
TRIM BOARDS TO BE 3/4" THICK CEMENTITIOUS BOARDS (U.N.O), SMOOTH TEXTURE. MINIMUM LENGTH OF BOARD BETWEEN CUT JOINTS SHALL 10'-0". ALL SIDING AND TRIM MUST BE FLASHED IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. PAINT PNT-03.
C
2'-0"
D
2'-0"
10'-0"
2'-0"
ALL STEEL TO BE PAINTED BLACK TO MATCH ADJACENT RAILINGS ON YORK COUNTY ARTS COUNCIL
ALL STEEL TO BE PAINTED BLACK TO MATCH ADJACENT RAILINGS ON YORK COUNTY ARTS COUNCIL
RAILING TO MEET ANSI A117.1
RAILING TO MEET ANSI A117.1
4" SPHERE SHALL NOT PASS
4" SPHERE SHALL NOT PASS
C
charleston 843.619.7662
3.
asheville 828.619.0301
2'-0"
NEW STOREFRONT DOOR CENTERED ON PATIO, FINISH TO BE BLACK TO MATCH
ALL EXTERIOR EXPOSED WOOD FRAMING (STUDS, BEAMS, RIM BOARDS, JOISTS, AND LEDGERS) TO BE PRESSURE TREATED UNLESS OTHERWISE NOTED. CONTRACTOR TO WEATHERIZE ANY PRESSURE TREATED WOOD TO BE STAINED OR PAINTED.
rock hill 803.324.5531
A
2.
contact@vin-yet.com
B
SEAMING, BREAK POINTS, PATTERNS, AND MATERIAL LENGTHS FOR ALL EXTERIOR MATERIALS INCLUDING SIDING, COPING, ROOFING, ETC. TO BE CENTERED ON THAT BUILDING ELEMENT OR LOCATED AT A NATURAL BREAK IN THE BUILDING. CONTACT ARCHITECT FOR SEAM LOCATION IF ONE IS NOT APPARENT.
312 Pendleton St. Rock Hill, SC 29730
D
1.
vinyet architecture HISTORIC REVIEW
ELEVATION NOTES:
Copyright © 2023 VinYet Architecture, LLC
3'-6"
3'-6"
This document is an instrument of service and shall remain the property of VinYet Architecture, LLC, who retains all common law, statutory and other reserved rights, including the copyright thereto.
Revision Schedule Rev #
LEVEL 02C 15'-3"
Revision Description
Date
LEVEL 02C 15'-3"
PERIMETER C CHANNEL PER STRUCTURAL
PERIMETER C CHANNEL PER STRUCTURAL
PLAN NORTH
TRUE NORTH
113 E. Main Street Rock Hill, SC 29730
MORTON AND GETTYS ATTORNEYS AT LAW PATIO
2ND FLOOR
EXTERIOR ELEVATIONS
A
A23001
12/8/2023 10:54:07 AM
V:\VYA\Projects\2023\A23001_Morton&Gettys\Revit\A23001_MortonAndGettys - Patio.rvt
ALIGN W/
B
2 PATIO ELEVATION 2 A201
1
A201
1 PATIO ELEVATION 1
3/4" = 1'-0"
A201
2
3
12.04.23
3/4" = 1'-0"
4
5
C
D
ALL STEEL TO BE PAINTED BLACK TO MATCH ADJACENT RAILINGS ON YORK COUNTY ARTS COUNCIL
NEW STOREFRONT DOOR CENTERED ON PATIO, FINISH TO BE BLACK TO MATCH
charleston 843.619.7662
A
asheville 828.619.0301
B
rock hill 803.324.5531
NEW STOREFRONT DOOR CENTERED ON PATIO, FINISH TO BE BLACK TO MATCH
5
contact@vin-yet.com
D
4
312 Pendleton St. Rock Hill, SC 29730
3
2
vinyet architecture HISTORIC REVIEW
1
8"
RAILING TO MEET ANSI A117.1 4" SPHERE SHALL NOT PASS
This document is an instrument of service and shall remain the property of VinYet Architecture, LLC, who retains all common law, statutory and other reserved rights, including the copyright thereto.
3'-6"
3'-6"
C
Copyright © 2023 VinYet Architecture, LLC
STEEL TERMINATION BAR PER STRUCTURAL
Revision Schedule Rev #
LEVEL 02C 15'-3"
Revision Description
Date
LEVEL 02C 15'-3"
CONCRETE PAD OVER METAL DECKING PER STRUCTURAL
CONCRETE PAD OVER METAL DECKING PER STRUCTURAL
C CHANNELCONNECTING PERIMETER C CHANNEL TO WIDE FLANGE, SEE STRUCTURAL
C CHANNELCONNECTING PERIMETER C CHANNEL TO WIDE FLANGE, SEE STRUCTURAL
WIDE FLANGE COLUMNS PER STRUCTURAL
WIDE FLANGE COLUMNS PER STRUCTURAL
CONNECTION PER STRUCTURAL
PLAN NORTH
TRUE NORTH
1'-6 3/4"
BUILDING SECTIONS
A
A23001
2 PATIO SECTION 2 A301
1 PATIO SECTION 1
3/4" = 1'-0"
A301
1
2
3
12.04.23
A301
LEVEL 01 0" 12/8/2023 10:54:07 AM
V:\VYA\Projects\2023\A23001_Morton&Gettys\Revit\A23001_MortonAndGettys - Patio.rvt
EXISTING ELECTRICAL METERS
113 E. Main Street Rock Hill, SC 29730
15'-3"
MORTON AND GETTYS ATTORNEYS AT LAW PATIO
B
3/4" = 1'-0"
4
5