Os isolamentos térmicos resistivos

Page 1

26

climatização

os isolamentos tĂŠrmicos resistivos MELHORAMENTOS DEVIDOS AO ISOLAMENTO TÉRMICO 1.ÂŞ PARTE Alfredo Costa Pereira 0HPEUR VÂŤQLRU GD 2UGHP GRV (QJHQKHLURV ̰ (VSHFLDOLVWD HP (QJHQKDULD GH &OLPDWL]DмR

O QUE É O ISOLAMENTO TÉRMICO ? 2 FDORU WUDQVIHUH VH HVSRQWDQHDPHQWH GRV ORFDLV REMHWRV RX FRUSRV PDLV TXHQWHV SDUD RV PDLV IULRV ‹ LPSRVVÂŻYHO ̸guardarâ€? o calor no in WHULRU GH XP UHFLSLHQWH SRU PDLV HVWDQTXH TXH HOH VHMD &RP XP ERP isolamento tĂŠrmico do recipiente apenas podemos “retardarâ€? a sua “fugaĚš PDV QÂĽR LPSHGL OD FRPR ÂŤ XP H[HPSOR D ̸garrafa termosâ€?. 1XP HGLIÂŻFLR DV SDUHGHV GR UHFLSLHQWH VÂĽR R SDYLPHQWR DV SDUHGHV com os seus vĂŁos envidraçados e a cobertura. Todos estes elementos GHYHP VHU WHUPLFDPHQWH LVRODGRV GD PHOKRU PDQHLUD LVWR ÂŤ FRP XPD HVSHVVXUD DGHTXDGD H GH XP PRGR FRQWÂŻQXR GH PRGR D HOLPLQDU RV IXURV H DV FKDPDGDV ̸pontes tĂŠrmicasâ€?. As perdas de calor atravĂŠs de XP HOHPHQWR GD VXD HQYROYHQWH VÂĽR SURSRUFLRQDLV ¢ ÂŁUHD GD VXD VX SHUIÂŻFLH H ¢ GLIHUHQŠD GH WHPSHUDWXUD HQWUH R LQWHULRU H R H[WHULRU 2 FRH ͤFLHQWH GH SURSRUFLRQDOLGDGH ÂŤ XPD FDUDWHUÂŻVWLFD GR WLSR GH FRQVWUX мR H GRV PDWHULDLV XWLOL]DGRV QD PHVPD H GHVLJQD VH SRU FRHͤFLHQWH JOREDO GH WUDQVIHUÂŹQFLD GH FDORU U, (3) desse elemento da envolvente. ([SULPH VH HP : P2. :DWW SRU PHWUR TXDGUDGR H SRU JUDX 1RWD 2 VÂŻPEROR . VLJQLͤFD DTXL .HOYLQ PDV QÂĽR VH PHQFLRQD SRUTXH R LQWHUYDOR GH JUDX ÂŤ R PHVPR TXHU VHMD QD HVFDOD .HOYLQ RX Celsius. 1RWD $QWLJDPHQWH QD (XURSD R VÂŻPEROR XWLOL]DGR SDUD GHVLJQDU R FRHͤFLHQWH JOREDO GH WUDQVIHUÂŹQFLD GH FDORU HUD R . QÂĽR FRQIXQGLU com o sĂ­mbolo K da escala de temperaturas Kelvin). A partir do ano SDUD GHVLJQDU R FRHͤFLHQWH JOREDO GH WUDQVIHUÂŹQFLD GH FDORU SDV VRX D XWLOL]DU VH R VÂŻPEROR 8 $VVLP XP PDWHULDO FRP D VXSHUIÂŻFLH GH bP2 TXH WHQKD XP FRHͤ ciente U b: P2K perde 1 Watt por cada grau de diferença de tempe ratura entre as suas faces. Durante uma estação de aquecimento com D GXUDмR GH GLDV H FRP XPD GLIHUHQŠD GH WHPSHUDWXUD PÂŤGLD GH bJUDXV D VXD SHUGD GH HQHUJLD VHUÂŁ [ [ bN:K RX VHMD R HTXLYDOHQWH D bOLWURV GH ̸mazoutâ€?. A Tabela seguinte fornece valores FRUUHQWHV SDUD R FRHͤFLHQWH 8 7DEHODb &RHͤFLHQWHV JOREDLV GH WUDQVIHUÂŹQFLD GH FDORU KDELWXDLV HP HGLIÂŻFLRV

Elemento de construção

U [W/m2K]

3DUHGH DQWLJD SRU H[HPSOR SDUHGH HP ̸tijolos isolantesâ€?)

D

Parede ou cobertura isolados segundo as normas modernas

$

/LPLWH PÂŁ[LPR SDUD DV SDUHGHV FRQIRUPH 6,$

NĂ­vel aproximado de rentabilidade ĂŠnergĂŠtique Ăłtimo

NĂ­vel aproximado de rentabilidade econĂłmica Ăłtimo

Bons vĂŁos envidraçados modernos (tipo “confortoâ€?)

$

Vidros duplos isolantes normalizados

3

Vidros simples

6

GD GH DU ‹ HVWD FDPDGD GH DU TXH FRQVWLWXL HIHWLYDPHQWH R LVRODPHQWR tĂŠrmico. (VWD FDPDGD GH DU LPRELOL]DGD PHOKRUD R FRQIRUWR WÂŤUPLFR WDQWR GXUDQWH R SHUÂŻRGR GH ,QYHUQR FRPR GXUDQWH R 9HUÂĽR DWHQGHQGR D TXH R FOLPD LQWHULRU SDVVD D GHSHQGHU PHQRV GDV FRQGLŠ¡HV H[WHULRUHV permitindo que as temperaturas das superfĂ­cies envolventes interiores se aproximem da temperatura do ar interior. Normalmente esta cama GD GH DU LPRELOL]DGD WDPEÂŤP PHOKRUD R FRPSRUWDPHQWR DFÂźVWLFR GR edifĂ­cio. 2 FRHͤFLHQWH JOREDO GH WUDQVIHUÂŹQFLD GH FDORU GDV SDUHGHV DQWLJDV IHLWDV HP DOYHQDULD GH SHGUD XQLGDV FRP DUJDPDVVD GH FLPHQWR ¢ SULPHLUD YLVWD QÂĽR SDUHFH VHU PXLWR IDYRUÂŁYHO SULQFLSDOPHQWH VH IRU calculado como se a parede fosse de pedra maciça. &RQWXGR ÂŤ QHFHVVÂŁULR QÂĽR HVTXHFHU TXH HVWDV SDUHGHV FRQWÂŹP LQÂźPHUDV FDYLGDGHV SULQFLSDOPHQWH GHYLGR ¢ SRURVLGDGH GD DUJDPDV VD GH FLPHQWR VHQGR SRU HVWD UD]ÂĽR PDLV LVRODQWHV GR TXH SRGHUÂŻD mos pensar. 3RU RXWUR ODGR HVWDV SDUHGHV VÂĽR PXLWR PDVVLYDV SHUPLWLQGR XPD H[FHOHQWH XWLOL]DмR GRV JDQKRV LQWHUQRV H GD UDGLDмR VRODU TXH SHQH tra pelos vĂŁos envidraçados. 1RV FDVRV GH REUDV GH UHVWDXUR QÂĽR ÂŤ DFRQVHOKÂŁYHO FRORFDU R LVR ODPHQWR SHOR LQWHULRU PHVPR QR FDVR GH VHU LPSRVVÂŻYHO FRORFÂŁ OR SHOR H[WHULRU GHYLGR D UD]¡HV GH RUGHP HVWÂŤWLFD RX RXWUDV

EFEITOS SOBRE O CONFORTO: -£ YLPRV TXH D VHQVDмR GH FRQIRUWR WUPLFR HVW£ UHODFLRQDGD VLPXO taneamente com a temperatura do ar dos locais de permanência e FRP D WHPSHUDWXUD VXSHUͤFLDO GD IDFH LQWHULRU GD HQYROYHQWH GHVVHV espaços. 'XUDQWH R ,QYHUQR D WHPSHUDWXUD GD IDFH LQWHULRU GH XPD SDUHGH H[WHULRU VHU£ WDQWR PDLV HOHYDGD TXDQWR PHOKRU LVRODGD HVWLYHU D SDUHGH 7RGRV FRQKHFHPRV D VHQVDмR GHVDJUDG£YHO GH IULR TXH VHQWL PRV TXDQGR QRV FRORFDPRV QD YL]LQKDQŠD GH XPD SDUHGH RX GH XP vão envidraçado termicamente mal isolados. A espessura mínima que GHYH WHU R LVRODPHQWR WUPLFR GH XPD SDUHGH RSDFD SDUD ID]HU GHVD SDUHFHU HVWH HIHLWR  GH D bFP Os vãos envidraçados atuais não são tão bem isolados como as SDUHGHV RSDFDV HPERUD VH HQFRQWUHP QR PHUFDGR YLGURV TXH V¼R a 4 vezes mais isolantes do que o vidro duplo vulgar. O conforto tÊr PLFR VHQWLGR QD YL]LQKDQŠD GH Y¼RV HQYLGUDŠDGRV IHLWRV FRP HVWH WLSR GH YLGURV  EDVWDQWH VXSHULRU DR VHQWLGR QD YL]LQKDQŠD GH XP YLGUR RUGLQ£ULR

EFEITO SOBRE O CONSUMO ENERGÉTICO: 2 LVRODPHQWR WÂŤUPLFR REWÂŤP VH JHUDOPHQWH LQWHUFDODQGR XPD FDPDGD GH PDWHULDO ͤEURVR RX HVSXPRVR FXMD IXQмR ÂŤ LPRELOL]DU XPD FDPD www.oelectricista.pt o electricista 61

2 LVRODPHQWR WUPLFR GRV HGLI¯FLRV WHP VLGR EDVWDQWH PHOKRUDGR GHV GH GHYLGR QDWXUDOPHQWH ¢ SXEOLFDмR GH GLYHUVDV QRUPDV $ 7D