LED DOWNLIGHT SERIES PL-DLC20-12W INSTALLATION GUIDE
RoHS
// CLEARANCE INFORMATION // COMBUSTIBLE BUILDING ELEMENT
Transformer 50mm
Barrier required for loose fill insulation or loose combustible materials
Combustible building structural member
A B
C
Thermal insulation
Location
Distance
Description
A
50mm (Minimum) 25mm (Minimum) 25mm (Minimum)
Clearance between the top of recessed luminaire and combustible materials.
B C
Recessed lumnaire
Clearance between structural member. Clearance between thermal insulation and luminaire.
Notice: 1. This downlight is only for indoor application. 2. Don’t look at the light directly when the downlight is on. 3. For any further information please contact PrimeLED.
// INSTALLATION DIAGRAM 1
2
LAMP CUT OUT Cut Out Size
1. Cut a hole in the ceiling.
2. Connect driver.
PL-DLC20 Ø70mm
3
CLOSE
OPEN
3A. To change Cover Plate turn anti-clockwise. B. Install New Cover Plate by turning clockwise. C. Make Sure silicon fitting is installed correctly.
PrimeLED Australia Warehouse / Showroom
4
4A. Place driver into ceiling. 4B. Install the downlight into the ceiling and adjust gimble to suit.