LED DOWNLIGHT SERIES PL-DLC20-12W INSTALLATION GUIDE

RoHS

// CLEARANCE INFORMATION // COMBUSTIBLE BUILDING ELEMENT

Transformer 50mm

Barrier required for loose fill insulation or loose combustible materials

Combustible building structural member

A B

C

Thermal insulation

Location

Distance

Description

A

50mm (Minimum) 25mm (Minimum) 25mm (Minimum)

Clearance between the top of recessed luminaire and combustible materials.

B C

Recessed lumnaire

Clearance between structural member. Clearance between thermal insulation and luminaire.

Notice: 1. This downlight is only for indoor application. 2. Don’t look at the light directly when the downlight is on. 3. For any further information please contact PrimeLED.

// INSTALLATION DIAGRAM 1

2

LAMP CUT OUT Cut Out Size

1. Cut a hole in the ceiling.

2. Connect driver.

PL-DLC20 Ø70mm

3

CLOSE

OPEN

3A. To change Cover Plate turn anti-clockwise. B. Install New Cover Plate by turning clockwise. C. Make Sure silicon fitting is installed correctly.

PrimeLED Australia Warehouse / Showroom

4

4A. Place driver into ceiling. 4B. Install the downlight into the ceiling and adjust gimble to suit.