HANDICAP ACCESSIBILITY DIAGRAMS - DOORS X
6" MAX.
CLEAR FLOOR SPACE AT LAVATORIES
66" MIN.
40" MAX.
34" MAX.
29" MIN.
Clear Floor Space
Protected Piping
48" MIN.
LAVATORY CLEARANCES
18" (24" pref'd)
60" min
30" MIN.
27" MIN.
9"
Clear Floor Space
48" MIN.
17" MIN.
4. Accessible routes to be provided between facilities, providing a minimum of 36 inches in width along the accessible route, and a minimum of 32 inches in width at doorways.
Note: Y=48" minimum if door has both a closer and a latch.
Note: X=12" if door has both a closer and a latch.
Lav.
19" MAX.
Lav.
3. Controls and operating mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist.
CLEAR FLOOR SPACE AT WATER CLOSETS
24" min Push Side
PLUMBING NOTES 1. 2. 3. 4.
PLUMBING FIXTURE SCHEDULE
All plumbing and gas piping work shall be installed in strict accordance with the requirements of Article 16 and Reference Standard RS 16 of the 2014 NYC Building Code.
1.
Plumbing fixtures shall be of type and manufacture approved for use in New York City, and shall bear BSA approval.
2.
All gas-fired equipment to be A.G.A. or M.E.A. approved. Plumbing Contractor to examine proposed layout with regard to existing field conditions, and shall notify Architect of any discrepancies between assumed field conditions and those encountered during construction. Plumbing contractor shall inform Architect of any revisions to plan which shall be necessary, based on conditions uncovered in the field, in order to install all fixtures, equipment and piping in strict accordance with the requirements of the NYC Building and Plumbing codes.
5.
Plumbing Contractor shall arrange and obtain inspections and required sign-offs.
6.
Remove or relocate all plumbing as required. Removed pipes shall be cut to a point of concealment behind or below finish surfaces, and shall be properly capped or plugged.
7.
All soil & vent piping shall be "no hub" cast iron.
8.
All branch piping of 4" Ø or greater shall be pitched 1/8" per foot or less than 1/4" per foot. All vent piping shall be pitched to drain.
9.
All hot and cold water piping shall be copper tubing type "L" with 95-5 soldered joints.
X
Above Finished Floor Access Panel Adjacent Air Conditioner Air Handling Unit Aluminum Architectural Block Bottom of Building Cabinet Ceiling Ceiling Height Centerline Ceramic Tile Closet Column Concrete Concrete Masonry Unit Continuous Control Joint Diameter Drinking Fountain Down Elevation Equal Existing Expansion Joint Exterior Fire Extinguisher Fire Extinguisher Cabinet
Reference A-500 for Plumbing Fixture tags. P.1
KOHLER WIDESPREAD BATHROOM SINK FAUCET (K-14406-4)
P.2
KOHLER WALL-MOUNTS BATHROOM SINK (K-2053)
P.3
KOHLER ONE-PIECE TOILET (K-3828)
P.4
FIAT MOP SINK (TSB-100)
P.5
AMERICAN STANDARD UTILITY FAUCET (8344.212)
PLUMBING RISER DIAGRAMS
Pull Side
24" min Pull Side
4"
TO GO
2.
2"
101
WC (ADA)
103
BAR
1 - 1/2" 2"
1 - 1/2" W.C.
2" 3"
3.
1 - 1/2" W.C.
LAV.
UNDERMOUNT SINK
2"
3"
4"
C01
104
2"
1 - 1/2"
LAV.
UNDERMOUNT SINK
CLEANOUT
WC (ADA)
2"
1 - 1/2"
FIRST FLOOR
102
2" 3"
3"
2" 3"
2"
CLOSET
C03
2"
1 - 1/2" NOTE: PLUMBING FIXTURES AT PREP AREA TO BE CONFIRMED BY KITCHEN CONSULTANT
1 - 1/2" W.C.
LAV.
MOP SINK
CELLAR TO SEWER AT SMITH STREET
3"
CLEANOUT 2"
3"
2"
CLEANOUT
CLEANOUT
3"
Scope of Work:
A new stair, new walls, new doors, new plumbing fixtures and fitting, new electrical work (including new lighting fixtures), a new finishes.
Location:
191 Smith Street, Brooklyn, NY 11231
Tax Block and Lot:
Block: 397, Lot: 07
Landmark:
NO
Zoning District: Overlay(s):
R6B Residential C2-4
Zoning Map:
16c 30132806F
Note: X=36" minimum if Y=60" X=42" minimum if Y=54"
Note: Y=54" minimum if door has a closer.
HINGE SIDE APPROACHES - SWING DOORS
LATCH SIDE APPROACHES - SWING DOORS
Certificate of Occupancy:
Plastic Laminate Plywood Quantity Radius Required Reinforcing Right Hand Roof Drain Rough Opening Schedule Section Similar Square Foot Stainless Steel Steel Structural / Structure Suspended Telephone Top of Top of Catch Basin Top of Curb Typical Verify In Field Vertical Vinyl Composite Tile Utility Water Closet With Without Wood
INTERIORS
CELINE CAROL LUI DESIGN 36 BOND ST, BROOKLYN, NY 11230 CCL@GMAIL.COM 408 578 9091
DRAWING INDEX A.F.F. A.P. ADJ. A.C. A.H.U. ALUM. ARCH. BLK. B.O. BLDG. CAB. CLG. CLG. HT. C.L. C.T. CL. COL. CONC. C.M.U. CONT. C.J. DIA. D.F. DN ELEV. EQ. EX'G. E.J. EXT. F.E. F.E.C.
Finish Finish Floor Floor Floor Drain Fluorescent Foot / Feet Galvanized Gypsum Wall Board Hardware Height Hollow Metal Horizontal Insulation Laminated Lavatory Left Hand Masonry Opening Maximum Mechanical Metal Minimum Mounted Necessary Nominal Not in Contract Not to Scale On Center Opposite Painted Pair Perforated
FIN. FIN. FL. FL. F.D. FLUOR. FT. GALV. G.W.B. HDWR. HT. H.M. HORIZ. INSUL. LAM. LAV. L.H. M.O. MAX. MECH. MTL. MIN. MTD. NEC. NOM. N.I.C. N.T.S. O.C. OPP. PTD. PR. PERF.
P.LAM. PLYWD. QTY. RAD. REQ'D. REINF. R.H. R.D. R.O. SCHED. SECT. SIM. S.F. ST. STL. STL. STRUCT. SUSP. TEL. T.O. T.C.B. T.O.C. TYP. V.I.F. VERT. V.C.T. UTIL. W.C. W/ W/O WD.
PROJECT NOTES 1.
RENOVATION OF A CAFE/BAR IN AN EXISTING ONE-STORY BUILDING PROJECT DATA
ABBREVIATIONS
Plumbing Fixture models are provided to establish a quality of fixture and an operational standard. Equivalent manufacturers are acceptable upon review and approval of Interior Designer.
10. Minimum supply to each fixture shall be 1/2" Ø. All fixtures shall have a shut-off valve at all fixture groups at the risers; provide stops at each fixture.
KITCHEN
Push Side
Note: Y=48" minimum if door has a closer.
Pull Side
FRONT APPROACHES - SWING DOORS
Y 42" min
Push Side
18"
Mirror Lever Valve
Y 42" min
36" MIN. 18"
a. Fixtures to be provided with the required clear floor space.
Y
2. Proposed bathrooms to comply with the applicable requirements of ICC A117.1-2009 for handicapped access, including:
191 SMITH STREET BROOKLYN, NY 11201
54" min
48" min
1. Proposed work to comply with applicable requirements of ICC A117.1-2009.
Y 48" min
HANDICAP ACCESSIBILITY DIAGRAMS AND NOTES - BATHROOMS
All work shall conform with the Contract and with the Project Manual included as part of these Construction Documents. Before commencing work, the Contractor shall file all required Certificates of Insurance with the Department of Buildings, obtain all required permits, and pay all fees required by governing New York City agencies. No work is to begin without proper permits. Examination of the site and portions thereof which will affect this work shall be made immediately by the Contractor, who shall compare existing conditions with the Drawings and satisfy him/herself as to the conditions under which work is to be performed. Contractor shall notify the Designer of any conditions requiring modification before proceeding with the work. Contractor shall at such time ascertain and check locations of existing structure. Contractor's bid shall be based upon this examination.
INTERIORS CONTINUED
T-100
PROJECT INFO & GENERAL NOTES
A-900 PARTITION SCHEDULE
A-050
REMOVALS FLOOR PLANS
A-910
A-100
CELLAR & FIRST FLOOR PLANS
DOOR SCHEDULE, DOOR TYPES, AND TYPICAL DETAILS
A-110
CELLAR & FIRST FLOOR POWER & SIGNAL PLANS
A-920
FINISH SCHEDULE
A-300 A-301
BUILDING SECTIONS BUILDING SECTIONS
A-500 A-501
INTERIOR BATHROOM PLANS INTERIOR ELEVATIONS
A-700 A-701
ENLARGED STAIR PLANS & SECTION ENLARGED STAIR SECTION
A-800 A-801
MILLWORK - SEATING MILLWORK - SEATING
PROJECT:
LEA
SYMBOL LEGEND 12. Contractor shall protect area and new or existing materials and finishes from damage which may occur from construction, demolition, dust, water, etc., and shall provide and maintain temporary barricades, closure walls, etc., as required to protect the public during the period of construction. Damage to new and existing materials, finishes, structures, and equipment shall be repaired or replaced to the satisfaction of the Client at no additional expense to the Client. 13. All work listed, shown, or implied on any Construction Document shall be supplied and installed by the Contractor, except where noted otherwise.
14. Contractor shall notify Designer immediately of all utilities determined in the course of construction as being necessary to be removed which have not otherwise been noted for removal in the Construction Documents. Contractor shall remove such utilities only after consultation with the Designer and Client. Whether predetermined in the Construction Documents 4. Contractor shall verify all dimensions, elevations and or determined in the field, disconnect, cut back to conditions at the site, confirm that the work is buildable as source, and cap all utility services removed. Seal all shown, and notify Designer in writing of any penetrations created by the removal of utilities to match discrepancies prior to proceeding with the work in adjacent construction and finishes. question. 15. All manufactured articles, materials, and equipment 5. All dimensions are to finish face of masonry, centerline of shall be installed, connected, erected, cleaned, and steel, face of finish or casework unless otherwise noted. conditioned per the manufacturer's instructions. In case Dimensions noted as "CLR" are not adjustable without of differences between manufacturer's instructions and Designer's review. Dimensions are not adjustable without the Contract Documents, the Contractor shall notify the Designer's approval unless noted as "+/-". Field Designer before proceeding with the work in question. determine dimensions marked "V.I.F." prior to commencement of construction, and notify any variances 16. All work noted "By Others" or "N.I.C." shall be provided to Designer for resolution. by the Client or under separate contract. Submit to the Designer and Client schedule requirements for this 6. "Align" shall mean to accurately locate finish faces in the "other" work in the construction progress schedule and same plane. coordinate as required to assure orderly sequence of installation. 7. The Contract Documents are complementary. What is shown or referred to on any shall be provided as though 17. The Contractor shall remove all rubbish and waste shown on all. materials of all Subcontractors and trades on a daily basis and shall exercise strict control over job cleaning 8. Do not scale drawings. Dimensions and notes shall to prevent any dirt, debris, or dust from affecting any govern. Drawings at a large scale shall take precedence finished areas in or outside the job site. Burning of over drawings of a small scale. Details shall govern over debris on site shall not be permitted. plans and elevations. 18. Upon completing the job, the Contractor shall leave the 9. Repetitive features not shown on Drawings shall be premises and all affected areas clean and in an orderly completely provided as if drawn in full. manner ready for move-in. This is to include cleaning of all glass (including inside of exterior glass) and frames, 10. Contractor to verify layout of partitions, doors, electrical both new and existing. outlets, data and telephone outlets, light fixtures, and switches with Designer prior to proceeding with 19. Plumbing and electrical work shall be performed by construction. Contractor to verify that no conflicts exist in persons licensed in their trades, who shall arrange for locations of any mechanical, telephone, data, electrical, and obtain inspections and required sign-offs. lighting and plumbing equipment (including all piping, ductwork and conduit) and that all required clearances for 20. The Contractor shall be responsible for the protection installation and maintenance are provided. of all conditions and materials within the proposed construction area. The Contractor shall design and 11. Visits to the site by the Designer are only intended to install adequate shoring and bracing for all structural or ensure compliance with the design intent and should not removal tasks. The Contractor shall have sole be construed as being related to site safety. responsibility for any damage or injuries caused by or during the execution of the work.
DOOR NUMBER
100
ROOM NAME
ROOM INFO
CONF. RM. 100
ROOM NUMBER
WINDOW NUMBER
1
WALL TYPE BUILDING ELEVATION
BUILDING SECTION
1
ELEVATION NUMBER
A-200
SHEET NUMBER
SECTION NUMBER
1 A-300
SHEET NOTE TAG ALIGN FINISHES
1
B
A-500
ELEVATION NUMBER SHEET NUMBER
RATED PARTITION
A
2
NEW GYP. BD. WALLS DRAWING:
SHEET NUMBER
A
INTERIOR ELEVATION D
REVISION
191 SMITH STREET BROOKLYN, NEW YORK 11201
EXISTING WALLS TO REMAIN
LEVEL CHANGE
1
NOT IN PROJECT SCOPE
PROJECT INFORMATION AND GENERAL NOTES
ALIGN
8"
EXISTING SWING DOOR TO REMAIN ISSUE DATE :
C
DETAIL TAG
1
DETAIL NUMBER
A-800
SHEET NUMBER
Z
COLUMN LINE
+ 8'-0"
CENTERLINE
CL
DRAWN BY :
CELINE LUI
NORTH ARROW PROJECT NUMBER :
COLUMN NUMBER
NEW SWING DOOR
INTERMEDIATE LANDING
ELEVATION HEIGHT
03.12.2020
NEW SLIDING DOOR
DRAWING :
2000 SEAL :
VICINITY MAP
NO SCALE
DOB JOB NUMBER :
DOCUMENT :
01
SITE DRAWING NUMBER:
T-100.00 S SCAN STICKER: