LRG CFI

Page 1

Fluorescent Lighting

Reliable Fluorescent Solutions

From CFI Fluorescent. It's in our name. You can depend on it. Dependability is our promise. Specifiers tell us we deliver on it with every order. How do we do it? Our well-designed luminaires are built with the most modern technology, practically applied, so you don't have to worry. CFI’s proven quality comes from a manufacturing and testing facility second to none, located in Cornwall, Ontario. Recently expanded, it is North America’s most modern fluorescent production facility and the only one in Canada dedicated to fluorescent lighting. We make sure our luminaires provide the latest in energy efficiency, visual comfort, controlled light distribution and all the features you need to meet your most challenging specifications. Above all, CFI is committed to producing the best fluorescent lighting fixtures you can find. The CFI family of fluorescent systems builds upon a solid foundation of quality design, high technology and engineering performance. Innovative luminaires support a thorough understanding of end-user requirements. Continually developing new products (see opposite page), CFI offers innumerable cost-effective, quality lighting solutions suited to a wide range of fluorescent applications.

8


Introducing more choice, more dependability Over 50 new CFI products are featured in the 2006 edition of the Canlyte Lighting Resource Guide, including Lytecel, TriLyte, Video Teleconference, Cleanguard and Guardsman. CFI Fluorescent has always taken a leading role in advancing lighting practices, allowing architects, specifiers and other lighting professionals to take full advantage of the most up-to-date lighting techniques. Discover all the reasons why you can rely on CFI: see pages 8 to 157.

New products

Lytecel pages 40-43

TriLyte pages 102-105

Video Teleconference pages 114-117

Cleanguard pages 108-123

Guardsman pages 124-137

9


VDT Story — Outline The ninth edition of the Illuminating Engineering Society of North America (IESNA) Lighting Handbook opens up a whole new era in lighting design. It introduces a wide range of lighting quality factors intended to improve the quality of the visual environment. These factors may include eyesource- task geometry, appearance. And lighting solutions based on the Quality of the Visual Environment will be providing many of the answers. Why? For one, we live in a customer driven world. Success is measured more and more in terms of how well people’s needs are met. This shift in values also has an impact. Different lighting is required for different needs, in accordance with important lighting design criteria. The IESNA (illuminating Engineering Society of North America) recognizes this. The IES developed its first recommended practice for VDT lighting in 1989 with the introduction of IES RP-24. This document outlined the working environment and made recommendations for lighting an area filled with the VDT vertical tasks combined with the normal reading and writing horizontal tasks. People working in this environment had to deal with glare on their screens from windows and the luminance of luminaries visible in their VDT screens. They also had to deal with glare from luminaries visible to them far off in the distance. The original recommended practice used luminance measured in candelas per meter squared as a benchmark for luminaire selection.

IESNA Quality of the Visual Environment

Human needs • visibility • task performance • visual performance • social communication • mood and atmosphere • health,safety,well-being • aesthetic udgment

LIGHTING QUALITY Economics and the environment • installation • maintenance • operation • energy • environment

Architecture • form • composition • style • codes and standards

In 2003 the office committee upgraded this standard and created a new benchmark base on new data and new VDT technology. The new recommended practice uses maximum candlepower as part of the luminaire selection criteria. VDT screens have changed from curved to flat and from monochrome to full color. This led to the changes in the luminaire selection criteria. CFI Fluorescent offers a broad range of VDT solutions to meet the new criteria. The following table shows a sample list of products suitable for these applications. There are 2 sets of criteria one for intensive use and one considered the basic design. This criteria can be used as a guide when the VDT quality is unknown.

IESNA Lighting handbook 9th Edition

• Newly developed intensity limits • To prevent selection fixture with high light intensity at critical viewing angles • Can cause distraction and glare

Maximum Luminous Intensity

• Intensity of light is measured in candelas

Angle From Vertical 55° 65° 75° 85°

VDT Intensive

VDT Normal

300 cd 220 cd 135 cd 45 cd

— 300 cd 185 cd 60 cd

• Chart shows new classification for fixtures used within office areas with VDT screens. • Office areas with older style glass faced screens are the most critcal in regards to glare, Newer LCD Flat Panel displays reduce this concern due to their non-glare surface • Consideration still needs to be exercised for visual discomfort from the direct view of the luminaire (VCP)

ANSI/IESNA RP-1-04

Quality Lighting Criteria Behind the IESNA Lighting Design Guide To help in evaluating a lighting task, the IESNA has developed a list of 19 quality lighting criteria, the following in abbreviated form is taken from the design criteria for Interior Applications. Their relative (weighted) importance to interior lighting applications is illustrated in the Lighting Design Guide shown opposite. Appearance of space and luminaires Both the arrangement of elements and their relationship to one another can provide visual clues that assist occupant orientation. It is important that the style of the luminaires, coordinate with and enhance the design and architecture of the space. Colour appearance Colour appearance can affect visibility and aesthetics. Daylight integration and control Outdoor views are deemed physiologically and psychologically important (e.g. focusing on distant objects helps relax the muscle of the eyes). Daylight and sunlight can be used to help light a space, but care should be taken to control the quantity and distribution of the light, and to control heat gain.

10

Direct glare Glare can cause discomfort and interfere with visibility. Direct glare occurs when light travels directly from the source to the eye. The IESNA has established glare criteria for luminaire luminances (see explanation of RP-1 Intensive and normal luminaire selection for VDT (visual display terminal) applications, page 10). Flicker Flicker is the rapid variation in light source intensity, usually most noticeable in peripheral vision. Flicker can make objects or people appear to move at a different rate from their actual movement. Light distribution on surfaces Patterns of light resulting from the spacing and light distribution of the luminaires, as well as from objects that can cast shadows, can affect task visibility, comfort and perceptions.

Light distribution on task plane (uniformity) Patterns of light on the task plane can be distracting, confusing or beneficial. These patterns of light and shadow can affect task visibility, comfort and perception. Task illuminance should be higher than the immediate surround. Work surface illuminances that are 1.5 to 3 times higher than those in the surrounding areas assist in directing the occupants’ attention to the task. Luminances of room surfaces Room surface luminances influence the perception of brightness in a space. Illuminance and reflectance affect luminance. Matte surfaces of high reflectance are effective materials for increasing room surface luminances. Luminaires expressly designed for lighting walls or ceilings are effective tools for increasing room surface luminances.


Modelling of faces or objects Lighting can reveal the depth, shape and texture of an object. Through the creation or elimination of shadows, faces and objects can have more or less contrast. Also, because a high percentage of communication is nonverbal, such as in office environments, it is important that the pattern of light on faces enables clear recognition and interpretation of expressions. Point(s) of interest A point of interest is the object or place to which attention is drawn, using a variety of techniques including configuration rhythm, luminance contrast and colour contrast. Reflected glare Also known as indirect glare, reflected glare occurs when polished or glossy surfaces emit uncomfortable bright reflections that reduce task visibility. Veiling reflections are contrast reducing reflections from semi-specular surfaces that reduce task visibility. Both phenomena can be mitigated by special luminaire optical designs that provide adequate cutoff, especially for VDT applications (see pages 10 and 11).

Shadows Shadows can interfere with task visibility by placing detail in darkness. They can also enhance definition of three-dimensional details. Fewer shadows (more uniform brightness) eliminate points of interest, contributing to a feeling of openness.

System control and flexibility Many spaces require different light levels for a variety of tasks. Conference rooms, for example, need to have equipment that provides for settings for slide shows, personnel interviews, presentations and cleaning.

Source/Task/Eye geometry The angular relationships between the viewer, the task and the luminaire are frequently critical to task visibility. This geometry can both enhance contrast and reduce it.

Special considerations Often there are special issues associated with a specific location or task. These are usually presented in the form of notes relating to the recommended practice.

Sparkle/Desirable reflected highlights Small points of high luminance from the luminaire or its components can enhance visual interest and architectural details.

Illuminance (horizontal) Horizontal illuminance is the density of luminous flux falling onto a horizontal surface.

Surface characteristics Object characteristics such as texture, colour, and specularity and reflectance values of surfaces, can affect the perceived brightness of walls and ceilings. High reflectances also allow the designer to produce an effective lighted environment with fewer watts and fewer luminaires.

Illuminance (vertical) Vertical illuminance is the density of luminous flux falling onto a vertical surface.

Quality Lighting IESNA Lighting Design Guide† Very important

Important

Somewhat important

Blank =Not important or not applicable

Category / Value (lux)*

Illuminance (vertical)

Category / Value (lux)*

Illuminance (horizontal)

Notes on special considerations

Special considerations

System control and flexibility

Surface characteristics

Sparkle / Desirable reflected highlights

Source / Task / Eye geometry

Shadows

Reflected glare

Point(s) of interest

Modelling of faces or obects

Luminances of room surfaces

Light distribution on surfaces

Flicker

Direct glare

Daylight integration and control

Colour appearance

INTERIOR APPLICATIONS

Appearance of space and luminaires

The Design Guide† (opposite) illustrates the new IESNA lighting recommendations for common interior applications.

LIGHTING DESIGN ISSUES

lighting quality

Light distribution on task plane (uniformity)

Setting a new course for

OFFICES Open-plan office: Intensive VDT use

(1, 2)

D

B

Intermittent VDT use

(1, 2)

E

B

E

B

Private office

Notes: • (1) Lighting should be flexible to accommodate changes in office furniture. • (2) Acoustical aspects of luminaires need to be considered. • (3) Consider lighting for video cameras. • (4) See special considerations for lighting healthcare facilities in Chapter 16 of the IESNA Lighting Handbook. • (5) The task may be horizontal, inclined or vertical. • (6) The minimum illuminance in a prison cell is 200 lx (20 fc); 300 lx (30 fc) should be provided for reading at the head of the bed.

*Determination of illuminance categories Orientation and simple visual tasks A Public spaces B Simple orientation for short visits C Working spaces where simple visual tasks are performed

30 lx (3 fc) 50 lx (5 fc) 100 lx (10 fc)

Common visual tasks D Performance of visual tasks of high contrast and large size 300 lx (30 fc) E Performance of visual tasks of high contrast and small size, or visual tasks of low contrast and large size 500 lx (50 fc) F Performance of visual tasks of low contrast and small size 1,000 lx (100 fc) Special visual tasks G Performance of visual tasks near threshold 3,000 to 10,000 lx (300 to 1,000 fc)

†CFI Fluorescent has edited the IESNA Design Guide for purposes of simplicity and brevity. The Guide is based on examples taken from the IESNA Lighting Handbbook 9th Edition Chapter 10. Lighting professionals requiring further details should consult the ninth edition of the IESNA Lighting Handbook. A copy of the Handbook can be obtained by contacting the Publications Department of the IESNA at 212- 248- 5000 or www. iesna. org.

11


T5 Highbay Story With TriLyte, CFI Fluorescent now offers a T5/T8 fluorescent solution for lowbay/ highbay lighting in retail, recreational and industrial applications. TriLyte provides the cost-effective benefits of fluorescent lamps, including quality lighting, superior energy efficiency and occupancy sensing capabilities.

See the Benefits that Fluorescent Light Can Give You Instant Light: TriLyte features no restrike/warmup delays. Instant-on T5/T8 TriLyte is well-adapted to speedy warehouse material placement and retrieval. Also, TriLyte fluorescent lighting is compatible with energy-saving controls, thereby creating new opportunities for occupancy sensing and full-intensity dimming. High CRI: TriLyte's punch of white light ideal for making merchandise stand out. TriLyte T5/T8 fluorescent lighting features high colour rendering indices that yield true, vivid colours ideally suited to retail applications. Low-Shadow Optic Design Both T8 and T5 lamps are effective at room temperature, with T5 lamping more ideally suited to warmer environments, such as gymnasiums and warehouses without climate control. The reflector design of this fixture is multi-chambered and individual to the lamp. This results in efficient, directional light which yeilds uniform and highly luminous light on vertical surfaces in areas such as warehouse racking and inventory storage. Lumen Maintenance New fluorescent lamps have improved lumen depreciation with some losing only 5% over their life, resulting in fewer fixtures needed for the same maintained light lowering both initial cost and operating cost

Sensor Positioning : On The Luminaire Or In The Lighted Area ? Much depends on your application. As a rule, remotely mounted configurations require fewer occupancy detectors per aisle because of the sensor’s long and narrow field of view. However, wider coverage with luminaire-mounted occupancy detectors may be better suited to certain locations.

Luminaire-Mounted Motion Sensor Field of view

• Wide coverage, ideal for warehouse aisle applications. • Detection pattern: 30-50 foot width at mounting heights of up to 45 ft. • Uses passive infrared (PIR) technology shielded by a fresnel lens; upon detection of infrared energy levels, the sensor is triggered and switches the light on. Remote-Mounted Motion Sensor Field of view

• Narrow coverage, ideal for long aisles. • Detection pattern: When mounted 30 ft. from floor (typical), range is 110 ft. x 15 ft. (width). • For aisles 100 ft. and over, use one sensor at each aisle extremity. • Uses passive infrared (PIR) technology

12


Lens Troffer Story Lens technologies are an important element in fluorescent lighting, they provide economic solutions for many less sensitive work and utlity areas within projects. Through the aide of lens technology application, the recessed troffer can even accommodate for specialized lighting needs at an affordable cost. The proper lens can supply: • Radio frequency emissions control • Ultra violet filtering

• Computer friendly lenses for VDT environments • Energy efficiency by a combination of symmetric / asymmetric distribution

CFI Fluorescent offers three levels of quality to service every application. General Specification Troffer AA family • Shallow 3 5/8” depth for low plenum application • Good value recessed luminaire for general lighting and design build projects • Very competitive pricing for high volume markets • Very efficient – over 74% luminaire efficiency (3-lamp model) • Built in hold down clips on 2x2 and 2x4 models

• Hemmed edges for safe handling • Hinged door frame with mitered corners • Cam action latches • Regressed aluminum door frame option • Reversible door frame

Mid-Grade Specification Troffer SQS family • 4” depth helps reduce lamp image against lens • Competitive performance with most specification grade troffers • Very efficient – up to 74% luminaire efficiency • Full size steel lens frame

• Cam action latches • One piece housing • Built in hold down clips on 2x2 and 2x4 models

Premium Specification Grade Troffers SPS family • 5” depth results in further reduction of lamp image against lens • Up to 83% efficiency • One piece housing has ribbed construction for added strength • Slimline door frame with 1,000 square inch lens opening

• Door jamb finished black on four sides for positive light stop • Flush and regressed aluminum door frame options • Spring loaded latches

Special Applications

Healthcare and Cleanroom Lighting • MD4 and MD Coffer surface multi-function fixtures • Precise light control for glare free environment • Multi-level control that includes Ambient, Reading, Examination and optional Nurse’s Night Light functions • Possiblities for integral low voltage sequential switch mounted in fixture that allows individual control by the patient throught the use of a pillow switch (others) • Wall mount fixture models BED and OBL offer possibilities independent uplight/downlight switching and nurse’s night light options. • Cleanroom fixture (see pages 118-119 ) availability includes a recessed troffer series with ratings of Class 1,000 to Class 10,000 . Designed for 1.5” and standard 15/16” tee and meets Federal Standard 209E for cleanroom application. Industrial and Security Lighting • Fixtures available to suit a majority of needs within Industrial environments • Fixtures suited for applications of concerns of gasses, vapors and liquids, combustible dust or fibers,or simply areas of wet locations, damp locations or areas of vibration or shock. • For security environments we have options in vandal resistance. A new line of fixtures address for higher security concerns with variations of 14-18 gauge steel housings and optional lenses materials of polycarbonate and tempered glass. Special Visual Environments • A new fixture designed for video teleconferencing, where vertical distribution and lighting control through dimming solutions are essential. • Specialized wall washing luminaries provide uniform wall washing of vertical surfaces • Wall mounted luminaries designed to light the ceilings in small office spaces

New Canadian Energy Efficient regulations

— Fluorescent Lamp Ballasts E N E R G Y S M A RT

National Resources Canada has assigned new ballast efficacies to comply with new regulations being set forth in the United States by the Department of energy. The new ballast efficacies affect ballasts that operate F32T8, F34T12, F40T10, or F40T12 rapid start; or F96T12IS, F96T12ES, F96T12HO, or F96T12HO ES fluorescent lamps. The new regulation has set higher limits to ballast efficacies, which as a result, will leave some ballast’s non-compliant. Ballasts affected by this new ruling are primarily T12 magnetic in origin. At present, all magnetic T12 ballast requests are presently being fulfilled by internal inventory supply. All T12 requests will be subject to availability by CFI Fluorescent based on its inventory at the time. In order to comply with the new regulation, ballast manufacturers have had to cease production of these models for OEM use since April 2005. Further information regarding the OEE — Canada’s Energy Efficient regulations can be found through this NRC - Natural Resources Canada website link : http://oee.nrcan.gc.ca/regulations/fluorescent_august2005.cfm?text=N&printview=N

13


P

ARABOLIC AND

14

L R ENS

ECESSED

L

UMINAIRES

VPA/VRA 2’x 4’ p. 18-19

VPA/VRA 2’x 2’ p. 20-21

VRA 2’x 2’ p. 22-23

ADS/ADA 8”x 48’p. 24-25

ADS 1’x 4’ p. 24-25

DZA/DXA 1’x 4’ - 1’x 5’ p. 26-27

DVS 20”x 60” p. 26-27

DVA 20”x 60” p. 26-27

VPA 1’x 4’ p. 28-29

VRA/STA 1’x 4’ p. 30-31

DPA 2’x 4’ p. 32-33

DPA 2’x 2’ p. 34-35

PLA 2’x 4’ p. 36-37

PLA 2’x 2’ p. 38-39

LIA9 9”x 48” p. 40-41

LCA9 9”x 48” / LCS8 8”x 48” p. 42-43

DDA/DQA 20”x 60” - 20”x 48”p. 44-45

MPA 2’x 2’ - 2’x 4’ p. 46-47

PRA 1’x 4’ - 2’x 2’ - 2’x 4’ p. 48-49

SPS 1’x 4’ - 2’x 2’ - 2’x 4’ p. 50-51

SQS 2’x 4’ p. 52-53

MR 1’x 4’ - 1’x 8’ p. 52-53

AA 1’x 4’ - 2’x 2’ - 2’x 4’ p. 54-55 AAS/ELS 1’x 4’ - 2’x 2’ - 2’x 4’ p. 56-57

DSA 20”x 60” p. 58-59

DTA 20”x 48”p. 58-59

WLRN 24”x 48” p. 60-61

WMRL 24”x 48” p. 62-63


P

ENDANT AND

S

URFACE

BLSW 24”x 48” (ceiling) p. 64-65

BLSW 24”x 48” (wall) p. 64-65

TSL p. 66-67

TCU p. 66-67

VRB 1’x 4’ p. 68-69

DPB 2’x 2’ - 2’x 4’ p. 70-71

ADB 8”x 48” - 1’x 4’ p. 72-73

MLB 2’x 2’ - 2’x 4’ p. 72-73

PNB 1’x 4’. - 2’x 2’ - 2’x 4’ p. 74-75

SLB 1’x 4’ - 2’x 2’ - 2’x 4’ p. 76-77

GMB 4’ - 8’ p. 78-79

CBS 4’ p. 80-81

TH 4’ - 8’ p. 80-81

TT 4’ p. 82-83

TN 2’ - 4’ - 8’ p. 82-83

TX 4’ p. 84-85

Vandal 1’x 2’ - 1’x 4’ p. 84-85

CSW/CTW 2’ - 3’ - 4’ p. 86-87

CCW p. 86

CVW 2’ - 3’ - 4’ p.87

CWBU/LWBU 2’ - 3’ - 4’ p. 88-89

Belmont I 4’ p. 90

Belmont II 4’ p. 90

Belmont Cloud 4’ p. 91

Lumiplex 1’x 4’ - 2’x 2’ - 2’x 4’ p. 91

15


S

TRIPS AND

NDUSTRIALS

T5 SV p. 92-93

T5 SM p. 92-93

T5 SS p. 92-93

T5 SV5R Symmetric p. 94-95

T5 SV5R Asymmetric p. 94-95

SB Strips p. 96-97

STG Staggered Strip p. 98-99

CSM Side Mount Strip p. 98-99

Trilyte 4’ - 8’ p. 102-103

Trilyte 4’ 6-Lamp p. 104-105

SB9R Narrow Beam Reflectors p. 100-101

SB9R Wide Beam Reflectors p. 100-101

EE/FF Industrial p. 106-107

TU Turret Industrial p. 106-107

S

PECIAL

16

I

A

PPLICATIONS

VT/VTS 4’- 8’ p. 108-109

SW 4’- 8’ 110-111

RVS 1’x 4’ - 2’x 2’ - 2’x 4’ p. 110-111

HSC 4’ p. 112-113

VTS 2’x 4’ p. 114-115

VTS 2’x 2’ p. 116-117

CXSW 2’x 2’ - 2’x 4’ p.118-119

CXS 2’x 2’ - 2’x 4’ p. 120-121

WES 2’x 2’- 2’x 4’ p. 122-123

RV Guardsman Corner Mount 4’ p. 124-125

RV Guardsman 1’x 4’ - 2’x 2, - 2’x 4’ RV Guardsman 1’x 4’ - 2’x 2, - 2’x 4’ p. 126-127 p. 128-129


S

PECIAL

A

PPLICATIONS

GVS 1’x 4’ - 2’x 2’- 2’x 4’ p. 130-131

GVB 1’x 4’ - 2’x 2’- 2’x 4’ p. 132-133

GV4 4’- 8’ p. 134-135

MD2 2’x 2’ / MD4 2’x 4’ p. 138-139 Multi-Function Luminaire

MDC 2’x 2’ - 2’x 4’ p. 140-141 Multi-Function Luminaire

SUS p.142-143 Recessed for Operating Room

OBL 4’ p. 146-147

BED 3’- 4’ p. 146-147

GSW 2’- 4’ p. 136-137

M

ÉDICAL

MDS p. 144-145 Recessed for Medical Exams

17


Recessed Luminaires Parabolic

Vision Smart 2’ x 4’ (VPA, VRA) 4” Deep Cells • Air Handling/Static Luminaires VPA2G29PR232120SO (Data)

VPA 2’x 4’

0

RCR

6" (152 mm)

500 1000

60°

24" (610 mm) 1437

48" (1219 mm)

PARABOLICS

Vision Smart 2 x 4 Parabolics meet the Preferred and Basic Criteria of IES RP-1. The troffers deliver medium to high levels with the best performance in terms of efficiency, wide spacing, and excellent glare control. The VP Series complies with the Preferred criteria and is especially suited wherever use of VDTs is prolonged and intensive. The VR Series complies with the Basic Criteria and is suited wherever use of VDTs is occasional or nonintensive. The 2-lamp models perform better than 3-lamp models. They deliver the RP-1 required 30-50 footcandles, with balanced brightness. They do not wash out the VDT or create excessive luminance ratios. Features •VP unit meets RP-1 preferred criteria for lighting VDT areas. •Candelas at Nadir (0°), 1437 on 2-lamp VP. • VP 2 lamp unit provides 50 maintained footcandles at .78 watts/sq. ft. (8 x 10) module. •Specular low iridescence pre-anodized louver in VP model. •VR unit meets IES RP-1 recommended criteria for lighting VDT areas. •Candelas at Nadir (0°), 1510 on 2-lamp VR. •Semi-specular low iridescence pre-anodized louver in VR model. •Concealed spring-loaded latch/hinge can be opened either side. •Only 6" deep. •Hold-down clips. •Protective film dust guard. •4” deep aluminum parabolic louver. Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming T8: OC T8: SO T8: PS 3 LPB T8: O3 (not avail. in 347V) T12 not available. LPB : Number of lamps per ballast. Drywall Kit For plaster frames, order Cat. No.: FK92X4 (2’ x 4’). Radio Interference Filter 120, 277 or 347 volt, 50 or 60 Hz. Suffix: R. Emergency Lighting System Suffix: O (e.g. VPA2G29PR232120SOO). Emergency battery pack with charger. (90 minutes at 15% of lumens for 1 lamp). Louver Finish Low iridescence specular is standard on VP models. Low iridescence semi-specular is standard on VR models. Air Pattern Control and Air Slot Closure For horizontal and vertical air supply and to balance return air. Suffix: S. Static For static luminaires, replace A in the basic catalogue number by S.

18 cells 18 Cells 0°

78 70

3 4

63 56

5 6

50 44

7 8

39 35

9 10

31 27

30°

VRA2G12LS232120SO (Data)

VRA 2’x 4’

0

6" (152 mm) 24" (610 mm)

RCR 1

500 60°

1000

1510

48" (1219 mm)

12 Cells cells 12 0°

C. U. 77

2 3

70 64

4 5

57 52

6 7 8 9 10

47 42 38 33 30

30°

VPA2G27PP332120O3 (Data)

VPA 2’x 4’

0

6" (152 mm) 1000

24" (610 mm)

60° 2000

48" (1219 mm)

2798

27 cells 27 Cells 0°

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 72 66 60 55 50 46 42 39 36 34

30°

VRA2G18LP332120O3 (Data)

VRA 2’x 4’

0

6" (152 mm) 1000

24" (610 mm)

60°

2000

48" (1219 mm)

2532

18 18 Cells cells 0°

18

C. U.

1 2

30°

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 70 64 58 52 48 44 40 37 34 31


Recessed Luminaires Parabolic Application Data*

Reference Data Efficiency Spacing Ratio

70.0% 1.8

Luminaire Spacing 50' x 70' x 8.5' Space

LUMINOUS INTENSITY

8' x 8' (64 sq ft/luminaire)

55° 65° 75° 85°

12' x 16' x 8.5' Space

75cd 0cd 0cd 0cd

Electronic Ballast Input Watts (120V) Ballast Factor

FC VCP W/Sq Ft

62

99

0.9

8' x 10' (80 sq ft/luminaire) 50

99

0.8

94

1.2

6' x 8' (48 sq ft/luminaire)

64

Ordering Guide Type Cells Air Handling

18

Lamps qty/type 2-T8

62.0W .88

8' x 8' (64 sq ft/luminaire)

40

99

0.9

Application Data*

Reference Data 70.9% 1.8

Luminaire Spacing

FC VCP W/Sq Ft

50' x 70' x 8.5' Space

LUMINOUS INTENSITY

8' x 8' (64 sq ft/luminaire)

62

97

0.9

55° 65° 75° 85°

8' x 10' (80 sq ft/luminaire) 50

97

0.8

91

1.2

537cd 45cd 10cd 2cd

Electronic Ballast Input Watts (120V) Ballast Factor

120

VPA2G29PR232

Ordering Guide Type Cells Air Handling

12

Voltage : 120 277 347

Lamps qty/type 2-T8

6' x 8' (48 sq ft/luminaire)

8' x 8' (64 sq ft/luminaire)

63

40

97

0.9

Application Data* 66.0% 1.5

Luminaire Spacing

8' x 8' (64 sq ft/luminaire)

55° 65° 75° 85°

12' x 16' x 8.5' Space

41cd 0cd 0cd 0cd

Electronic Ballast

FC VCP W/Sq Ft

50' x 70' x 8.5' Space

LUMINOUS INTENSITY

Exposed T-Grid VRA2G12LS232

120

VRA2G12LS232

87

99

1.3

8' x 10' (80 sq ft/luminaire) 71

98

1.1

95

1.8

6' x 8' (48 sq ft/luminaire)

95

Ordering Guide Type Cells Air Handling

27

Voltage :

Lamps qty/type 3-T8

Options : See page 18 Add appropriate suffix to catalogue number

Exposed Slot-T or Concealed T-Grid VRA2T12LS232

SO Ballast :

Exposed T-Grid VPA2G27PP332

Options :

Exposed Slot-T or Concealed T-Grid VPA2T27PP332

8' x 8' x 8.5' Cubicle/60" Partition 85.0W .88

8' x 8' (64 sq ft/luminaire)

57

99

1.3

120

VPA2G27PP32 Basic catalogue number :

Reference Data

Application Data*

Efficiency Spacing Ratio

Luminaire Spacing

64.5% 1.4

8' x 8' (64 sq ft/luminaire)

55° 65° 75° 85°

12' x 16' x 8.5' Space

971cd 81cd 24cd 0cd

Electronic Ballast

FC VCP W/Sq Ft

50' x 70' x 8.5' Space

LUMINOUS INTENSITY

Input Watts (120V) Ballast Factor

Ballast : See page 18

8' x 8' x 8.5' Cubicle/60" Partition 62.0W .88

Reference Data

Input Watts (120V) Ballast Factor

SO

12' x 16' x 8.5' Space

Basic catalogue number :

Efficiency Spacing Ratio

Exposed Slot-T or Concealed T-Grid VPA2T29PR232

8' x 8' x 8.5' Cubicle/60" Partition

Basic catalogue number : 4" Deep Precision Contoured Preanodized Aluminum Parabolic Louver

Efficiency Spacing Ratio

Exposed T-Grid VPA2G29PR232

85

96

1.3

8' x 10' (80 sq ft/luminaire) 70

96

1.1

87

1.8

6' x 8' (48 sq ft/luminaire)

90

Ordering Guide Type Cells Air Handling

18

Voltage :

Lamps qty/type 3-T8

03 Ballast :

Exposed T-Grid VRA2G18LP332

Options :

Exposed Slot-T or Concealed T-Grid VRA2T18LP332

8' x 8' x 8.5' Cubicle/60" Partition 85.0W .88

8' x 8' (64 sq ft/luminaire)

55

96

1.3

VRA2G18LP332 Basic catalogue number :

*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens

120 Voltage :

03 Ballast :

Options :

19


Recessed Luminaires Parabolic

Vision Smart 2’ x 2’ (VPA, VRA) 4” Deep Cells • Air Handling/Static Luminaires VPA 2’x 2’

VPA2G16PR2FT120SB (Data)

0

RCR

6" (152 mm)

500 60° 1000

24" (610 mm) 1598

24" (610 mm)

PARABOLICS

Vision Smart VP/VR architecturally symmetrical 2 x 2 Parabolics meet the Preferred and Basic Criteria of IES RP-1. The troffers deliver medium to high levels with the best performance in terms of efficiency, wide spacing, and excellent glare control. The VP Series complies with the Preferred criteria and is especially suited wherever use of VDTs is prolonged and intensive. The VR Series complies with the Basic Criteria and is suited wherever use of VDTs is occasional or nonintensive. Features •VP unit meets IES RP-1 preferred criteria for lighting VDT areas. •Candelas at Nadir (0°), 1598 on 2-lamp VP. •Specular low iridescence pre-anodized louver in VP model. •VR 9 cell unit meets IES RP-1 recommended criteria for lighting VDT areas. •Candelas at Nadir (0°), 1224 on 2-lamp VR. •Semi-specular low iridescence pre-anodized louver in VR models. •Concealed spring-loaded latch/hinge can be opened either side. •Only 6" deep. •Louver frame with integral positive light stop. •Hold-down clips. •Protective film dust guard. •4” deep aluminum parabolic louver. Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming 40W TT5: BX 40W TT5: SB 40W TT5: PB T8: OC 50W TT5: BE T8: PS 55W TT5: BF (not avail. in 347V) T8: SO 3 LPB T8: O3 T12 not available. LPB : Number of lamps per ballast. Drywall Kit For plaster frames, order Cat. No.: FK92X2 (2’ x 2’). Radio Interference Filter 120, 277 or 347 volt, 50 or 60 Hz. Suffix: R. Emergency Lighting System Suffix: O (e.g. VPA2G16PR2FT120SBO). Emergency battery pack with charger. (90 minutes at 15% of lumens for 1 lamp). Louver Finish Low iridescence specular is standard on VP models. Low iridescence semi-specular is standard on VR models. Air Pattern Control and Air Slot Closure For horizontal and vertical air supply and to balance return air. Suffix: S. Static For static luminaires, replace A in the basic catalogue number by S.

16 16 Cells cells 0°

VRA 2’x 2’

66 61

3 4

55 50

5 6

46 42

7 8

38 35

9 10

32 30

30°

VRA2G16LV2FT120SB (Data)

0

6" (152 mm)

RCR 1

500 60° 1000

24" (610 mm)

1224

24" (610 mm) 16 Cells cells 16 0°

VPA 2’x 2’

30°

C. U. 57

2 3

52 48

4 5

43 39

6 7 8 9 10

36 32 29 26 23

VPA2G12PP317120O3 (Data)

0

6" (152 mm)

500 60°

24" (610 mm) 1000 1225

24" (610 mm) 12cells Cells 12 0°

VRA 2’x 2’

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 68 63 58 53 49 45 41 37 34 31

30°

VRA2G9LP317120O3 (Data)

0

6" (152 mm)

500 60°

24" (610 mm) 1000

24" (610 mm)

1219

cells 99Cells 0°

20

C. U.

1 2

30°

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 69 63 58 53 48 44 40 37 33 30


Recessed Luminaires Parabolic Application Data*

Reference Data Efficiency Spacing Ratio

60.9% 1.7

Luminaire Spacing 50' x 70' x 8.5' Space

LUMINOUS INTENSITY

8' x 8' (64 sq ft/luminaire)

55° 65° 75° 85°

12' x 16' x 8.5' Space

145cd 5cd 0cd 0cd

Electronic Ballast Input Watts (120V) Ballast Factor

FC VCP W/Sq Ft

56

98

1.1

8' x 10' (80 sq ft/luminaire) 46

98

0.9

93

1.5

6' x 8' (48 sq ft/luminaire)

60

74.0W .90

8' x 8' (64 sq ft/luminaire)

36

98

1.1

16

2-TT5

Exposed T-Grid VPA2G16PR2FT

52.2% 1.8

Luminaire Spacing

FC VCP W/Sq Ft

50' x 70' x 8.5' Space

LUMINOUS INTENSITY

8' x 8' (64 sq ft/luminaire)

48

98

1.1

55° 65° 75° 85°

8' x 10' (80 sq ft/luminaire) 39

98

0.9

94

1.5

191cd 36cd 10cd 2cd

Electronic Ballast

120

VPA2G16PR2FT Basic catalogue number : 4" Deep Precision Contoured Preanodized Aluminum Parabolic Louver

Application Data*

Reference Data

Input Watts (120V) Ballast Factor

Air Handling

Lamps qty/type

Exposed Slot-T or Concealed T-Grid VPA2T16PR2FT

8' x 8' x 8.5' Cubicle/60" Partition

RE835 lamp rated at 3150 lumens

Efficiency Spacing Ratio

Ordering Guide Type Cells

Ordering Guide Type Cells Air Handling

16

Voltage : 120 277 347

Lamps qty/type 2-TT5

BX Ballast : See page 20

Exposed T-Grid VRA2G16LV2FT

Options : See page 20 Add appropriate suffix to catalogue number

Exposed Slot-T or Concealed T-Grid VRA2T16LV2FT

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

46

8' x 8' x 8.5' Cubicle/60" Partition 74.0W .90

8' x 8' (64 sq ft/luminaire)

31

98

1.1

120

VRA2G16LV2FT Basic catalogue number :

Voltage :

SB Ballast :

Options :

RE835 lamp rated at 3150 lumens

Application Data*

Reference Data Efficiency Spacing Ratio

62.1% 1.4

Luminaire Spacing 50' x 70' x 8.5' Space

LUMINOUS INTENSITY

8' x 8' (64 sq ft/luminaire)

55° 65° 75° 85°

12' x 16' x 8.5' Space

93cd 4cd 1cd 0cd

Electronic Ballast Input Watts (120V) Ballast Factor

FC VCP W/Sq Ft

36

99

0.7

8' x 10' (80 sq ft/luminaire) 30

99

0.6

95

1.0

6' x 8' (48 sq ft/luminaire)

40

Ordering Guide Type Cells Air Handling

12

Lamps qty/type 3-T8

Exposed T-Grid VPA2G12PP317

Exposed Slot-T or Concealed T-Grid VPA2T12PP317

8' x 8' x 8.5' Cubicle/60" Partition 47.0W .90

8' x 8' (64 sq ft/luminaire)

23

99

0.7

120

VPA2G12PP317 Basic catalogue number :

Voltage :

03 Ballast :

Options :

RE835 lamp rated at 1400 lumens

Reference Data

Application Data*

Efficiency Spacing Ratio

Luminaire Spacing

62.7% 1.4

50' x 70' x 8.5' Space

LUMINOUS INTENSITY

8' x 8' (64 sq ft/luminaire)

55° 65° 75° 85°

12' x 16' x 8.5' Space

377cd 30cd 7cd 0cd

Electronic Ballast Input Watts (120V) Ballast Factor

FC VCP W/Sq Ft

36

98

0.7

8' x 10' (80 sq ft/luminaire) 30

98

0.6

92

1.0

6' x 8' (48 sq ft/luminaire)

40

Ordering Guide Type Cells Air Handling

9

Lamps qty/type 3-T8

Exposed T-Grid VRA2G9LP317

Exposed Slot-T or Concealed T-Grid VRA2T9LP317

8' x 8' x 8.5' Cubicle/60" Partition 47.0W .90

8' x 8' (64 sq ft/luminaire)

23

98

0.7

VRA2G9LP317 Basic catalogue number :

120 Voltage :

03 Ballast :

Options :

RE835 lamp rated at 1400 lumens

*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor.

21


Recessed Luminaires Parabolic

Vision Smart 2’ x 2’ (VRA) 4” Deep Cells • Air Handling/Static Luminaires VRA2G9LS26U120SO (Data)

VRA 2’x 2’

0

RCR

6" (152 mm)

500 60°

24" (610 mm) 1000

24" (610 mm)

PARABOLICS

Vision Smart architecturally symmetrical 2 x 2 VR Parabolics meet the Basic Criteria of IES RP-1 (except 9 cells, 3 x TT5). This luminaire delivers medium to high levels with the best performance in terms of efficiency, wide spacing, and excellent glare control. The VR Series complies with the Basic Criteria and is suited wherever use of VDTs is occasional or non intensive.

9 cells Cells

62 56

3 4

50 46

5 6

41 38

7 8

34 32

9 10

29 27

30°

VRA2G16LS26U120SO (Data)

VRA 2’x 2’

Features •VR units meet IES RP-1 recommended criteria for lighting VDT areas (except 9 cells, 3 x TT5). •Only 6" deep. •Specular low iridescence pre-anodized louver. •Concealed spring-loaded latch/hinge can be opened either side. •Louver frame with integral positive light stop. •Hold-Down clips. •Shipped with removable protective film dust guard. •4” deep aluminum parabolic louver. Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming 40W TT5: BX 40W TT5: SB 40W TT5: PB T8: OC 50W TT5: BE T8: PS 55W TT5: BF (not avail. in 347V) 3 LPB TT5: X3 T8: SO 3 LPB T8: O3 LPB : Number of lamps per ballast. . Drywall Kit For plaster frames, order Cat. No.: FK92X2 (2’ x 2’). Radio Interference Filter 120, 277 or 347 volt, 50 or 60 Hz. Suffix: R. Emergency Lighting System Suffix: O (e.g. VRA2G9LS26U120SOO). Emergency battery pack with charger. (90 minutes at 15% of lumens for 1 lamp). Louver Finish Low iridescence semi-specular is standard. Air Pattern Control and Air Slot Closure For horizontal and vertical air supply and to balance return air. Suffix: S. Static For static luminaires, replace A in the basic catalogue number by S.

1521

C. U.

1 2

0

6" (152 mm)

RCR 1 500 60°

24" (610 mm) 1000

24" (610 mm) 16 cells Cells

1737

VRA 2’x 2’

C. U. 57

2 3

52 47

4 5

44 40

6 7 8 9 10

37 34 32 29 27

30°

VRA2G9LP32U120O3 (Data)

0

6" (152 mm) 1000

24" (610 mm)

24" (610 mm)

60°

2000

99 cells Cells

2442

VRA 2’x 2’

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 62 57 52 48 44 40 37 33 30 27

30°

VRA2G12PP32U120O3 (Data)

0

6" (152 mm) 24" (610 mm)

500 1000

60°

24" (610 mm) 2453

12 Cells 0°

22

30°

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 61 56 52 48 44 40 37 34 30 28


Recessed Luminaires Parabolic Application Data*

Reference Data Efficiency Spacing Ratio

57.1% 1.3

Luminaire Spacing 50' x 70' x 8.5' Space

LUMINOUS INTENSITY

8' x 8' (64 sq ft/luminaire)

55° 65° 75° 85°

12' x 16' x 8.5' Space

565cd 45cd 10cd 1cd

Electronic Ballast Input Watts (120V) Ballast Factor

FC VCP W/Sq Ft

50

96

0.9

8' x 10' (80 sq ft/luminaire) 41

97

0.8

87

1.2

6' x 8' (48 sq ft/luminaire)

53

Ordering Guide Type Cells Air Handling

9

Lamps qty/type 2-T8U6

8' x 8' (64 sq ft/luminaire)

33

96

0.9

120

VRA2G9LS26U Basic catalogue number : 4" Deep Precision Contoured Preanodized Aluminum Parabolic Louver

Application Data*

Reference Data 51.7% 1.2

Luminaire Spacing

FC VCP W/Sq Ft

50' x 70' x 8.5' Space

LUMINOUS INTENSITY

8' x 8' (64 sq ft/luminaire)

43

98

0.9

55° 65° 75° 85°

8' x 10' (80 sq ft/luminaire) 36

98

0.8

93

1.2

277cd 37cd 8cd 0cd

Electronic Ballast Input Watts (120V) Ballast Factor

Ordering Guide Type Cells Air Handling

16

Voltage : 120 277 347

Lamps qty/type 2-T8U6

6' x 8' (48 sq ft/luminaire)

49

8' x 8' (64 sq ft/luminaire)

28

98

0.9

Application Data*

Reference Data 56.7% 1.4

Luminaire Spacing

8' x 8' (64 sq ft/luminaire)

55° 65° 75° 85°

12' x 16' x 8.5' Space

1009cd 80cd 19cd 1cd

Electronic Ballast

FC VCP W/Sq Ft

50' x 70' x 8.5' Space

LUMINOUS INTENSITY

Exposed T-Grid VRA2G16LS26U

120

VRA2G16LS26U

74

96

1.3

8' x 10' (80 sq ft/luminaire) 62

96

1.0

84

1.8

6' x 8' (48 sq ft/luminaire)

82

Ordering Guide Type Cells Air Handling

9 9

Voltage :

Lamps qty/type 3-T8U1.6 3-TT5

Options : See page 22 Add appropriate suffix to catalogue number

Exposed Slot-T or Concealed T-Grid VRA2T16LS26U

SO Ballast :

Exposed T-Grid VRA2G9LP32U VRA2G9LP3FT

Options :

Exposed Slot-T or Concealed T-Grid VRA2T9LP32U VRA2T9LP3FT

8' x 8' x 8.5' Cubicle/60" Partition 83.0W .92

8' x 8' (64 sq ft/luminaire)

55

96

1.3

120

VRA2G9LP32U Basic catalogue number :

Reference Data

Application Data*

Efficiency Spacing Ratio

Luminaire Spacing

55.5% 1.4

8' x 8' (64 sq ft/luminaire)

55° 65° 75° 85°

12' x 16' x 8.5' Space

229cd 13cd 5cd 2cd

Electronic Ballast

FC VCP W/Sq Ft

50' x 70' x 8.5' Space

LUMINOUS INTENSITY

Input Watts (120V) Ballast Factor

Ballast : See page 22

12' x 16' x 8.5' Space

Basic catalogue number :

Input Watts (120V) Ballast Factor

SO

8' x 8' x 8.5' Cubicle/60" Partition 60.0W .88

Efficiency Spacing Ratio

Exposed Slot-T or Concealed T-Grid VRA2T9LS26U

8' x 8' x 8.5' Cubicle/60" Partition 60.0W .88

Efficiency Spacing Ratio

Exposed T-Grid VRA2G9LS26U

73

98

1.3

8' x 10' (80 sq ft/luminaire) 61

98

1.0

90

1.8

6' x 8' (48 sq ft/luminaire)

81

Ordering Guide Type Cells Air Handling

12 12

Voltage :

Lamps qty/type 3-T8U1.6 3-TT5

03 Ballast :

Exposed T-Grid VRA2G12PP32U VRA2G12PP3FT

Options :

Exposed Slot-T or Concealed T-Grid VRA2T12PP32U VRA2T12PP3FT

8' x 8' x 8.5' Cubicle/60" Partition 83.0W .92

8' x 8' (64 sq ft/luminaire)

56

98

1.3

VRA2G12PP32U Basic catalogue number :

*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

120 Voltage :

03 Ballast :

Options :

23


Recessed Luminaires Parabolic

Vision Smart 8” x 48”, 1’ x 4’ (ADS, ADA) Linear • Air Handling/Static Luminaires ADS8G16MS132

ADS 8”x 48”

ADS8G16MS132120SO (Data) 5-1/2" (140 mm)

0

RCR

5-1/2" (140 mm)

500 60°

8" (203 mm) 1000

48" (1219 mm) 1462

A unique one lamp luminaire that meets IES RP-1 prefered criteria with a smooth light distribution for 300 to 500 lux light levels.

PARABOLICS

Features •Meets IES RP-1 Preferred Criteria. •Ideal for intensive VDT use areas. •Body 5-1/2" deep, 16 cell model. •Body 4" deep, 32 cell model. •Louver securely held with concealed torsionite spring clips. •Luminaire efficiency 62.4% (16 cell). •Luminaire efficiency 62% (32 cell). •Ceiling Compatability Exposed T-Grid G only.

C. U.

1 2

67 63

3 4

58 54

5 6

50 46

7 8

43 39

9 10

36 33

30°

16 16Cells Cells

ADA 8”x 48”

ADA8G16MS132120SO (Data) 5-1/2" (140 mm)

0

RCR 1

5-1/2" (140 mm)

500 60°

8" (203 mm) 1000

48" (1219 mm)

1462 0°

C. U. 67

2 3

63 58

4 5

54 50

6 7 8 9 10

46 43 39 36 33

30°

16 Cells Cells 16

ADS1G32MS232

ADS 1’x 4’

ADS1G32MS232120SO (Data)

0

4" (102 mm) 10-13/16" (275 mm) 12" (305 mm)

48" (1219 mm)

32 Cells 32

Ultra shallow 4” (102 mm) 2-lamp luminaire that meets IES RP-1 preferred criteria with a smooth light distribution for 300-700 lux light levels. Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming T8: OC T8: SO T8: PS T12 not available. Drywall Kit For plaster frames, order Cat. No.: FK91X4 (1’ x 4’), FK907X4 (8” x 4’). Radio Interference Filter 120, 277 or 347 volt, 50 or 60 Hz. Suffix: R. Emergency Lighting System Suffix: O (e.g. ADS8G16MS132120SOO). Emergency battery pack with charger. (90 minutes at 15% of lumens for 1 lamp). Louver Finish Reflector matte low iridescence, pre-anodized aluminum (standard). For other finishes, consult factory.

24

1000

60°

2000

2340 0°

30°

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 68 63 58 53 49 45 42 39 36 34


Recessed Luminaires Parabolic Application Data*

Reference Data Efficiency Spacing Ratio

62.4% 1.0

Luminaire Spacing

FC VCP W/Sq Ft

50' x 70' x 8.5' Space

Static

LUMINOUS INTENSITY

8' x 6' (48 sq ft/luminaire)

33

99

0.6

55° 65° 75° 85°

8' x 8' (64 sq ft/luminaire)

25

99

0.5

26

99

0.6

5 cd 0 cd 0 cd 0 cd

Electronic Ballast Input Watts (120V) Ballast Factor

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

Ordering Guide Type Luminaire size

Static Self-flange

8" x 48" 8" x 48" 8" x 48" 8" x 48" 8" x 48" 8" x 48"

Cells

Lamp qty/type

16 16 16 16 16 16

1-T8 1-T5 28W 1-T5 54W 1-T8 1-T5 28W 1-T5 54W

8' x 8' x 8.5' Cubicle/60" Partition 31.0W .88

8' x 6' (48 sq ft/luminaire)

21

99

0.6

120

ADS8G16MS132 Basic catalogue number : 4" Deep Precision Contoured Preanodized Aluminum Parabolic Louver

Application Data*

Reference Data Efficiency Spacing Ratio

62.4% 1.0

Luminaire Spacing

FC VCP W/Sq Ft

50' x 70' x 8.5' Space 8' x 6' (48 sq ft/luminaire)

33

99

0.6

55° 65° 75° 85°

5 cd 0 cd 0 cd 0 cd

8' x 8' (64 sq ft/luminaire)

25

99

0.5

26

99

0.6

31.0W .88

8' x 6' (48 sq ft/luminaire)

Electronic Ballast

Ordering Guide Type Luminaire size Air Handling

LUMINOUS INTENSITY

Input Watts (120V) Ballast Factor

8" x 48" 8" x 48" 8" x 48"

Ballast : See page 24

Cells

Lamp qty/type

16 16 16

1-T8 1-T5 28W 1-T5 54W

Options : See page 24 Add appropriate suffix to catalogue number

Catalogue number ADA8G16MS132 ADA8G16MS128 ADA8G16MS154

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

8' x 8' x 8.5' Cubicle/60" Partition 21

99

0.6

Application Data*

Reference Data 62.0% 1.2

Luminaire Spacing

8' x 8' (64 sq ft/luminaire)

55° 65° 75° 85°

12' x 16' x 8.5' Space

4 cd 0 cd 0 cd 0 cd

Electronic Ballast

FC VCP W/Sq Ft

50' x 70' x 8.5' Space

LUMINOUS INTENSITY

Input Watts (120V) Ballast Factor

SO

Voltage : 120 277 347

120

ADA8G16MS132 Basic catalogue number :

Efficiency Spacing Ratio

Catalogue number ADS8G16MS132 ADS8G16MS128 ADS8G16MS154 ADS8L16MS132 ADS8L16MS128 ADS8L16MS154

Static 46

99

1.0

8' x 10' (80 sq ft/luminaire) 39

99

0.8

99

1.3

6' x 8' (48 sq ft/luminaire)

Ordering Guide Type Luminaire size

46

12" x 48" 12" x 48" 12" x 48"

SO

Voltage :

Ballast :

Cells

Lamp qty/type

32 32 32

2-T8 2-T5 28W 2-T5 54W

Options :

Catalogue number ADS1G32MS232 ADS1G32MS228 ADS1G32MS254

8' x 8' x 8.5' Cubicle/60" Partition 62.0W .88

8' x 8' (64 sq ft/luminaire)

31

99

1.0

ADS1G32MS232 Basic catalogue number :

120 Voltage :

SO Ballast :

Options :

Ceiling Tile

5-1/2" (140 mm) 8 1/4" (210mm) Self-flange ADS8L.

*Average Footcandles Maintained Total LLF=BF (.88)x .85 = .75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

25


Recessed Luminaires Parabolic

Vision Smart 1’x 4’, 12”x 60”, 20”x 60”, 300mm x 1500mm, 500mm x 1500mm Faceplate • m I perial and eMtric • Air Handling/Static Luminaires DZA1G16MS132120S0

DXA 12”x 60”

DXA1G16MS132120SO (Data)

5-1/2" (140 mm) 0

6-1/4" (158 mm) 12" (305 mm)

RCR

500 60°

1000

60" (1525 mm)

16 Cells

A unique one lamp luminaire that meets IES RP-1 prefered criteria with a smooth light distribution for 300 to 500 lux light levels.

1462 0°

PARABOLICS

Features •Meets IES RP-1 Preferred Luminance Criteria. •Ideal for intensive VDT use areas. •Body 5-1/2" deep, 16 cells model. •Body 4" deep, 32 cells model. •Faceplate made with die-formed 20 gauge steel with edges hemmed for rigidity (DXA, DZA, DKA, DNA and DVA). •Full length 40” air slots with bent edge for rigidity (air supply, return luminaire) (DXA, DZA, DKA, DNA and DVA). •Louver securely held with concealed torsionite spring clips. •Luminaire efficiency 62.4% (16 cell). •Luminaire efficiency 62% (32 cell). •Ceiling Compatability Exposed T-Grid G only.

DZA 1’x 4’

500

12" (305 mm)

60°

1000

48" (1219 mm)

16 Cells

1462 0°

DVA 20”x 60”

5 6

50 46

7 8

43 39

9 10

36 33

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 67 63 58 54 50 46 43 39 36 33

30°

DVA5G32MS232120SO (Data) 4" (102 mm)

10-13/16" (275 mm) 20" (508 mm)

60" (1525 mm)

0

1000

60°

2000

RCR 1 2 3 4 5 6 7 8 9 10

2340

26

58 54

0

DVS5G32MS232

Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec HDF Dimming T8: OC T8: SO T8: PS (not available in 347) T12 not available. Drywall Kit For plaster frames, order Cat. No.: FK91X4 (DZ), FK20X60 (DV-20” x 60”). Radio Interference Filter 120, 277 or 347 volt, 50 or 60 Hz. Suffix: R. Emergency Lighting System Suffix: O (e.g. DXA1G16MS132120SOO). Emergency battery pack with charger. (90 minutes at 15% of lumens for 1 lamp). Louver Finish Reflector matte low iridescence, pre-anodized aluminum (standard). For other finishes, consult factory. Static For static luminaires, replace A in the basic catalogue number by S.

3 4

30°

6-1/4" (158mm)

32 Cells

67 63

DZA1G16MS132120SO (Data)

5-1/2" (140 mm)

DVA5G32MS232

C. U.

1 2

30°

C. U. 68 63 58 53 49 45 42 39 36 34


Recessed Luminaires Parabolic Application Data*

Reference Data Efficiency Spacing Ratio

62.4% 1.0

LUMINOUS INTENSITY 55° 65° 75° 85°

5cd 0cd 0cd 0cd

FC VCP W/Sq Ft

50' x 70' x 8.5' Space

Ordering Guide Type Luminaire size Air Handling

10' x 10' checkerboard (50 sq ft/luminaire)

33

99

0.5

8' x 8' (64 sq ft/luminaire)

25

99

0.5

27

99

0.6

Cells

Lamp qty/type

12" x 60"

16

1-T8

Catalogue number DXA1G16MS132

300mm x 1500mm

16

1-T8

DKA1G16MS132

10' x 15' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing

31.0W .88

DXA1G16MS132 Luminaire : Vision Smart 12” x 60”

Application Data*

Reference Data Efficiency Spacing Ratio

62.4% 1.0

Luminaire Spacing

FC VCP W/Sq Ft

50' x 70' x 8.5' Space 8' x 6' (48 sq ft/luminaire)

33

99

0.6

55° 65° 75° 85°

8' x 8' (64 sq ft/luminaire)

25

99

0.5

26

99

0.6

5cd 0cd 0cd 0cd

SO

Voltage : 120 277 347

Ordering Guide Type Luminaire size Air Handling

LUMINOUS INTENSITY

120

12" x 48"

Ballast : See page 26

Cells

Lamp qty/type

16

1-T8

Options : See page 26

Catalogue number DZA1G16MS132

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

Electronic Ballast Input Watts (120V) Ballast Factor

31.0W .88

DZA1G16MS132 Luminaire :

Application Data*

Reference Data Efficiency Spacing Ratio

62.0% 1.2

LUMINOUS INTENSITY 55° 65° 75° 85°

FC VCP W/Sq Ft

50' x 70' x 8.5' Space

4cd 0cd 0cd 0cd

63

99

1.0

13.3' x 10' checkerboard 65 (64 sq ft/luminaire)

99

0.9

99

1.2

Ballast :

Options :

Cells

Lamp qty/type

20" x 60"

32

2-T8

Catalogue number DVA5G32MS232

500mm x 1500mm

32

2-T8

DNA5G32MS232

10' x 15' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

52

62.0W .90

DVA5G32MS232 Luminaire :

300mm x 1500mm DK Series

SO

Voltage :

Ordering Guide Type Luminaire size Air Handling

10' x 10' checkerboard (50 sq ft/luminaire)

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing

120

500mm x 1500mm DN Series

163 mm

Voltage :

SO Ballast :

Options :

279 mm

140 mm

105 mm 276 mm

159 mm

500 mm

300 mm

1500 mm

120

1190 mm 1016 mm

1500 mm

16 Cells Cell 16 32 Cell Cells *Average Footcandles Maintained Total LLF=BF (.88) x .85 = .75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor. RE835 lamp rated at 3000 lumens

27


Recessed Luminaires Parabolic

Vision Smart 1’x 4’ (VPA, Asymmetric VPA) 3”Deep Cells • Air Handling/Static Luminaires VPA1G12PR132120SO (Data)

VPA 1’x 4’

0

6-5/8" (168 mm)

RCR 250

12" (305 mm)

500

48" (1219 mm)

PARABOLICS

Vision Smart 1' x 4' VP Parabolics meet the preferred criteria of IES RP-1. This luminaire delivers low to medium light levels with the best performance in terms of efficiency, wide spacing, and excellent glare control. Both 1 lamp and 2 lamp models are especially suited wherever use of VDT’s is prolonged and intense. The 1 lamp model is ideal for VDT areas where there are no paper tasks and 20 to 30 footcandle light levels may be preferred. The Asymmetric 1' x 4' is for lighting walls adjacent to perimeter fixtures and eliminates “cave” effect caused by sharp cut-off luminaires. Features •Meets IES RP-1 preferred for lighting VDT areas. •Vertical grain on louver eliminates reflected lamp images on cross baffle. •Asymmetric side baffle and semi-specular aluminum upper reflector (Asymmetric 1 lamp unit only). •Louver frame with positive light stop. •Spring-loaded latches (self-centering). •Only 6-5/8" deep. •Black housing exterior for cooler ballast operating temperature. •Hold-Down clip (pat. No. 5,072,344). •3” deep aluminum parabolic louver. Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming T8: OC T8: SO T8: PS (not avail. in 347V) T12 not available. Drywall Kit For plaster frames, order Cat. No.: FK91X4 (1’ x 4’). Radio Interference Filter 120, 277 or 347 volt, 50 or 60 Hz. Suffix: R. Emergency Lighting System Suffix: O (e.g. VPA1G12PR132120SOO). Emergency battery pack with charger. (90 minutes at 15% of lumens for 1 lamp). Louver Finish Low iridescence specular is standard on VP models. Consult factoy for other finishes. Air Pattern Control and Air Slot Closure For horizontal and vertical air supply and to balance return air. Suffix: S. Static For static luminaires, replace A in the basic catalogue number by S.

967

12 12 cells Cells 0°

79 73

3 4

67 61

5 6

56 52

7 8

47 43

9 10

38 35

30°

VPA1G24PS232120SO (Data)

VPA 1’x 4’

0

6-5/8" (168 mm) 12" (305 mm)

60°

1000

48" (1219 mm)

2000 2267

24 24 Cells cells

Asymmetric VPA 1’x 4’

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 68 63 58 54 49 46 42 39 35 33

30°

VPA1G12PA132120SO (Data)

0

6-5/8" (168 mm) 60°

12" (305 mm)

500

60°

817

48" (1219 mm)

1000

30°

30°

12 cells Cells

Hold-Down clip before installation

28

60°

C. U.

1 2

Hold-Down clip installed


Recessed Luminaires Parabolic Application Data*

Reference Data Efficiency Spacing Ratio

Luminaire Spacing

72.0% 1.6

50' x 70' x 8.5' Space

LUMINOUS INTENSITY 55° 65° 75° 85°

FC VCP W/Sq Ft

8' x 8' (64 sq ft/luminaire)

65cd 0cd 0cd 0cd

32

95

0.5

8' x 10' (80 sq ft/luminaire) 26

96

0.4

93

0.6

Ordering Guide Type Cells Air Handling

12

Lamps qty/type 1-T8

Slot-T or Concealed T VPA1T12PR132

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

Electronic Ballast

31

8' x 8' x 8.5' Cubicle/60" Partition

Input Watts (120V) Ballast Factor

30W .88

8' x 8' (64 sq ft/luminaire)

16

98

120

VPA1G12PR132

0.5

Basic catalogue number : Vision Smart 3" Deep Parabolic

Application Data*

Reference Data Efficiency Spacing Ratio

Luminaire Spacing

61.5% 1.1

FC VCP W/Sq Ft

50' x 70' x 8.5' Space

LUMINOUS INTENSITY 55° 65° 75° 85°

Exposed T-Grid VPA1G12PR132

8' x 8' (64 sq ft/luminaire)

114cd 5cd 1cd 0cd

48

94

1.0

8' x 10' (80 sq ft/luminaire) 40

84

0.8

96

1.3

Ordering Guide Type Cells Air Handling

24

SO

Voltage : 120 277 347

Lamps qty/type

Ballast : See page 28

Exposed T-Grid VPA1G24PS232

2-T8

Options : See page 28 Add appropriate suffix to catalogue number

Slot-T or Concealed T VPA1T24PS232

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

Electronic Ballast

51

8' x 8' x 8.5' Cubicle/60" Partition

Input Watts (120V) Ballast Factor

62W .88

8' x 8' (64 sq ft/luminaire)

31

94

120

VPA1G24PS232

0.8

Basic catalogue number :

Spacing MH

4'

5'

6'

7'

8'

9' 10' 11' 12' 13' 14' 15' 16' 17' 18' 19' 20'

9.50

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

8.50 23 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24

Ordering Guide Type Cells Air Handling

12

SO

Voltage :

Lamps qty/type

Ballast :

Exposed T-Grid VPA1G12PA132

1-T8

Options :

Slot-T or Concealed T VPA1T12PA132

7.50 22 24 24 25 25 25 25 25 25 25 25 25 25 25 25 25 25 6.50 24 26 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 5.50 23 26 27 28 28 28 28 28 28 28 28 28 28 28 28 28 28 4.50 19 21 22 23 24 24 24 24 24 24 24 24 24 24 24 24 24 3.50 15 16 18 18 19 19 20 20 20 20 20 20 20 20 20 19 19 2.50 12 14 14 15 16 16 16 16 17 17 17 17 17 16 16 16 16

VPA1G12PA132 Basic catalogue number :

120 Voltage :

SO Ballast :

Options :

1.50 10 11 12 12 13 13 13 13 14 14 14 14 14 13 13 13 13 0.50

9

10 10 11 11 11 12 12 12 12 12 12 12 12 12 11 11

*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

29


Recessed Luminaires Parabolic

Vision Smart, Stacklyte 1’x 4’ (VRA, STA) 3”Deep Cells • Air Handling/Static Luminaires VRA1G8LS132120SO (Data)

VRA 1’x 4’

0

RCR

6-5/8" (168 mm)

73 66

500

3 4

60 54

649

5 6

48 43

7 8

39 34

9 10

30 27

250 60°

12" (305 mm)

48" (1219 mm)

PARABOLICS

Vision Smart (VR) luminaires 1 lamp 8 cell, 2 lamp 12 cell comply with the Basic Criteria of RP-1 and are suited for use in VDT areas. The 1 lamp model is ideal for VDT areas with task/ambient lighting and 20 to 30 footcandle light levels may be preferred. Stacklyte (STA) is excellent for lighting library bookshelves with 97.5% of the luminaire distribution in the 0°-60° zone. This achieved with a 95% reflective specular reflector. Features Meets IES RP-1 recommended (minimum requirements) for lighting VDT areas (VR 1 lamp 8 and 12 cell, 2 lamp 12 cell) • Semi-specular low iridescence pre-anodized louver. • Vertical grain on louver eliminates reflected lamp images on cross baffle. • Louver frame with positive light stop. • Spring-loaded latches (self centering). • Black housing exterior for cooler ballast operating temperature. • Turned-in edges for safe handling. •3” deep aluminum parabolic louver. Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming T8: OC T8: SO T8: PS (not avail. in 347V) Drywall Kit For plaster frames, order Cat. No.: FK91X4 (1’ x 4’). Radio Interference Filter 120, 277 or 347 volt, 50 or 60 Hz. Suffix: R. Emergency Lighting System Suffix: O (e.g. VRA1G8LS132120SOO). Emergency battery pack with charger. (90 minutes at 15% of lumens for 1 lamp). Louver Finish Low iridescence semi-specular is standard. Consult factoy for other finishes. Air Pattern Control and Air Slot Closure For horizontal and vertical air supply and to balance return air. Suffix: S. Static For static luminaires, replace A in the basic catalogue number by S.

8 Cells cells

12 12cells Cells

30°

VRA1G24LS232120SO (Data)

VRA 1’x 4’

0

6-5/8" (168 mm)

500 60°

12" (305 mm)

1000

48" (1219 mm)

1687

2424cells Cells

RCR 1 2 3 4 5 6 7

C. U. 61 56 51 47 42 39 35

8 9

32 29

10

27

30°

Stacklyte STA 1’x 4’

STA1G8LR132120SO (Data)

0 6-5/8" (168 mm)

48" (1219 mm)

12" (305 mm)

8 Cells 8 cells

6-5/8" (168 mm)

12" (305 mm)

48" (1219 mm)

250 60°

500

927

1212 cells Cells 0°

30

C. U.

1 2

30°


Recessed Luminaires Parabolic *Application Data

Reference Data Efficiency Spacing Ratio

Luminaire Spacing

67.9% 1.9

50' x 70' x 8.5' Space

LUMINOUS INTENSITY 55° 65° 75° 85°

8' x 8' (64 sq ft/luminaire)

548cd 65cd 17cd 5cd

30

89

0.5

8' x 10' (80 sq ft/luminaire) 25

90

0.4

87

0.6

Ordering Guide Type Cells Air Handling

8 12 8 12

Lamps qty/type 1-T8 1-T8 2-T8 2-T8

6' x 8' (48 sq ft/luminaire)

30W .88

8' x 8' (64 sq ft/luminaire)

29

15

91

0.5

*Application Data

Reference Data

Luminaire Spacing

50% 1.1

FC VCP W/Sq Ft

50' x 70' x 8.5' Space

Electronic Ballast Input Watts (120V) Ballast Factor

Slot-T or Concealed T VRA1T8LS132 VRA1T12LW132 VRA1T8LS232 VRA1T12LW232

8' x 8' x 8.5' Cubicle/60" Partition

120

VRA1G8LS132 Basic catalogue number : Vision Smart 1’ x 4’

Efficiency Spacing Ratio

Exposed T-Grid VRA1G8LS132 VRA1G12LW132 VRA1G8LS232 VRA1G12LW232

12' x 16' x 8.5' Space

Electronic Ballast Input Watts (120V) Ballast Factor

FC VCP W/Sq Ft

8' x 8' (64 sq ft/luminaire) 62W .88

39

81

1.0

8' x 10' (80 sq ft/luminaire) 33

82

0.8

71

1.3

Ordering Guide Type Cells Air Handling

24

SO

Voltage : 120 277 347

Lamps qty/type

Ballast : See page 30

Exposed T-Grid VRA1G24LS232

2-T8

Options : See page 30 Add appropriate suffix to catalogue number

Slot-T or Concealed T VRA1T24LS232

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

41

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire

25

83

1.0

120

VRA1G24LS232 Basic catalogue number :

VERTICAL FOOTCANDLES ON BOOK SHELVES Ceiling 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 11.00 12.00

1' 48 36 28 24 21 18 16 16 15 14 12 10

48 36 28 24 21 18 16 16 15 14 12 10

49 36 28 24 21 18 16 16 15 14 12 10

2' 48 36 28 24 21 18 16 16 15 14 12 10

48 36 28 24 21 18 16 16 15 14 12 10

3' 48 36 28 24 21 18 16 16 15 14 12 10

49 36 28 24 21 18 16 16 15 14 12 10

4' 48 36 28 24 21 18 16 16 15 14 12 10

48 36 28 24 21 18 16 16 15 14 12 10

Floor

0'

1'

2'

3'

4'

Ordering Guide Type Cells Air Handling

8 8 12 12

STA1G12LR232 Basic catalogue number :

SO

Voltage :

Lamps qty/type

Ballast :

Exposed T-Grid STA1G8LR132 STA1G8LR232 STA1G12LR132 STA1G12LR232

1-T8 2-T8 1-T8 2-T8

120 Voltage :

Options :

Slot-T or Concealed T STA1T8LR132 STA1T8LR232 STA1T12LR132 STA1T12LR232

SO Ballast :

Options :

Book shelf aisle width, 36"

* Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

31


Recessed Luminaires Parabolic

Deepcel Series 2’ x 4’ (DPA) 3”Deep Cells • Air Handling/Static Luminaires DPA2G12LS232120SO (Data)

DPA 2’x 4’

5" (127 mm) 24" (610 mm)

0

RCR

600 60° 1200

48" (1219 mm)

PARABOLICS

Lightolier Deepcel is the industry standard 3" parabolic louver troffer with features that offer value above the industry standard. Deepcel housings have a clean white interior without holes or bends. Black painted exteriors reduce heat build-up within the lamp/ballast compartment(s) for optimum lamp and ballast efficiency. 24 cell configuration meets IES RP-1 recommended (basic) criteria for VDT areas.

1800

12 12Cells Cells 2400 0°

67 59

5 6

53 48

7 8

43 39

9 10

36 33

0

24" (610 mm)

1000 60°

48" (1219 mm)

2000 2502

18 18 Cells Cells 0°

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 83 74 66 59 53 48 43 40 36 33

30°

DPA2G18LP332120O3 (Data)

0

5" (127 mm) 24" (610 mm) 1000

48" (1219 mm) Cells 24 24 Cells Cells 18 Cells

60°

2000

2620 0°

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 84 75 67 60 54 49 44 40 37 34

30°

DPA2G32LS432120O4 (Data)

DPA 2’x 4’

0

5" (127 mm) 24" (610 mm)

1000 60° 2000

48" (1219 mm) 32 32 Cells Cells

3182 0°

32

3 4

30°

5" (127 mm)

DPA 2’x 4’

Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming T8: OC T8: SO T8: PS T5/T5HO: PG 3 LPB T5/T5HO: PU (not avail. in 347V) 4 LPB T5/T5HO: PV LPB : Number of lamps per ballast. Drywall Kit For plaster frames, order Cat. No.: FK92X4 (2’ x 4’). Radio Interference Filter 120, 277 or 347 volt, 50 or 60 Hz. Suffix: R. Emergency Lighting System Suffix: O (e.g. DPA2G12LS232120SOO). Emergency battery pack with charger. (90 minutes at 15% of lumens for 1 lamp). Louver Finish Low iridescence semi-specular is standard. Except DPA 24 cells : Low iridescence specular. Consult factoy for other finishes. Air Pattern Control and Air Slot Closure For horizontal and vertical air supply and to balance return air. Suffix: S. Static For static luminaires, replace A in the basic catalogue number by S.

85 76

DPA2G18LS332120O3 (Data)

DPA 2’x 4’

Features •Only 5" deep. • Vertical grain on louver eliminates reflected lamp image on cross baffle. •Spring-loaded latches. •Mitered aluminum louver flange. •3 lamp, 18 cell (77.7% efficient). •1.6 spacing to mounting height ratio. •Snap-in ballast cover. •Louver has polyethylene dust guard. •Black exterior finish for cooler ballast operation. •24 cell louver configuration meets IES RP-1 recommended (basic) for VDT applications (3-T8 only). •Built-in Hold-Down clip. •3" deep aluminum parabolic louver. •Available in in T8, T5 and T5HO combinations.

C. U.

1 2

30°

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 69 62 56 50 45 41 37 34 32 29


Recessed Luminaires Parabolic Application Data*

Reference Data Efficiency Spacing Ratio

80.0% 2.0

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

62.0W .88

FC VCP W/Sq Ft

69

92

0.9

8' x 10' (80 sq ft/luminaire) 56

93

0.8

80

1.2

Ordering Guide Type Cells Air Handling

12 12 12

Lamps qty/type

Exposed T-Grid DPA2G12LS232 DPA2G12LS228 DPA2G12LS254

2-T8 2-T5 2-T5HO

Slot-T or Concealed T DPA2T12LS232 DPA2T12LS228 DPA2T12LS254

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

66

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

36

92

0.9

120

DPA2G12LS232 Basic catalogue number : 3" Deep Precision Contoured Preanodized Aluminum Parabolic Louver

Application Data*

Reference Data Efficiency Spacing Ratio

77.6% 1.6

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

85.0W .88

FC VCP W/Sq Ft

102 92

8' x 10' (80 sq ft/luminaire) 84

1.3

93

1.1

79

1.8

Ordering Guide Type Cells Air Handling

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

85

18 18 18 18 18 18

SO

Voltage : 120 277 347

Lamps qty/type

Ballast : See page 32

Exposed T-Grid DPA2G18LS332 DPA2G18LS432 DPA2G18LS328 DPA2G18LS354 DPA2G18LS428 DPA2G18LS454

3-T8 4-T8 3-T5 3-T5HO 4-T5 4-T5HO

Options : See page 32 Add appropriate suffix to catalogue number

Slot-T or Concealed T DPA2T18LS332 DPA2T18LS432 DPA2T18LS328 DPA2T18LS354 DPA2T18LS428 DPA2T18LS454

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

55

92

1.3

120

DPA2G18LS332 Basic catalogue number :

Application Data*

Reference Data Efficiency Spacing Ratio

77.7% 1.6

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

85.0W .88

FC VCP W/Sq Ft

100 92

8' x 10' (80 sq ft/luminaire) 82

1.3

93

1.1

79

1.8

Ordering Guide Type Cells Air Handling

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

97

18 24 18 18 24 24

03

Voltage :

Lamps qty/type

Ballast :

Exposed T-Grid DPA2G18LP332 DPA2G24PP332 DPA2G18LP328 DPA2G18LP354 DPA2G24PP328 DPA2G24PP354

3-T8 3-T8 3-T5 3-T5HO 3-T5 3-T5HO

Options :

Slot-T or Concealed T DPA2T18LP332 DPA2T24PP332 DPA2T18LP328 DPA2T18LP354 DPA2T24PP328 DPA2T24PP354

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

56

92

1.3

120

DPA2G18LP332 Basic catalogue number :

Reference Data

Application Data*

Efficiency Spacing Ratio

Luminaire Spacing

64.1% 1.4

Electronic Ballast Input Watts (120V) Ballast Factor

50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

112.0W .88

FC VCP W/Sq Ft

109 93

8' x 10' (80 sq ft/luminaire) 90

1.8

94

1.4

112 79

2.3

Ordering Guide Type Cells Air Handling

32 32 32

03

Voltage :

Lamps qty/type

Ballast :

Exposed T-Grid DPA2G32LS432 DPA2G32LS428 DPA2G32LS454

4-T8 4-T5 4-T5HO

Options :

Slot-T or Concealed T DPA2T32LS432 DPA2T32LS428 DPA2T32LS454

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

67

93

1.8

DPA2G32LS432 Basic catalogue number :

*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

120 Voltage :

04 Ballast :

Options :

33


Recessed Luminaires Parabolic

Deepcel Series 2’ x 2’ (DPA) 3”Deep Cells • Air Handling/Static Luminaires DPA 2’x 2’

DPA2G9LS26U120SO (Data)

0

RCR

5" (127 mm) 500

24" (610 mm)

60°

24" (610 mm)

PARABOLICS

Deepcel 2 x 2 parabolic troffers feature all of the design benefits of the 2 x 4 product. Available with T12, T8 and TT5 type lamps in 9 or 16 cell configurations, Deepcel 2 x 2 is only 5" deep and is fast becoming the preferred choice in performance lighting specifications for general office lighting. Features •Only 5" deep. •3" deep aluminum parabolic louver. • Vertical grain on louver eliminates reflected lamp image on cross baffle. •2 lamp, 9 cell T8U6 (66.2% efficient). •3 lamp, 9 cell TT5 (72.0% efficient). •Spring-loaded latches. •Mitered aluminum louver flange. •Snap-in ballast cover. •Louver has polyethylene dust guard. •Black exterior finish for cooler ballast operation. •3" deep aluminum parabolic louver.

1000

12 Cells

9 Cells

1552

3 4

56 50

5 6

45 41

7 8

37 34

9 10

31 29

DPA2G9LP32U120O3 (Data)

0

5" (127 mm) 500 24" (610 mm)

60° 1000

24" (610 mm) 9 Cells

12 Cells 2102 0°

Options pages 150-156 Ballast Specify voltage (120, 277 or 347) add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming 40W TT5: BX 40W TT5: SB 40W TT5: PB T8: OC 50W TT5: BE T8: PS 55W TT5: BF (not avail. in 347V) 3 LPB 40W TT5: X3 T8: SO 3 LPB T8: O3 LPB : Number of lamps per ballast. Drywall Kit For plaster frames, order Cat. No.: FK92X2 (2’ x 2’). Radio Interference Filter 120, 277 or 347 volt, 50 or 60 Hz. Suffix: R. Emergency Lighting System Consult CFI Fluorecent Representative. Louver Finish Low iridescence semi-specular is standard. Consult factoy for other finishes. Air Pattern Control and Air Slot Closure For horizontal and vertical air supply and to balance return air. Suffix: S. Static For static luminaires, replace A in the basic catalogue number by S.

71 63

30°

DPA 2’x 2’

C. U.

1 2

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 68 62 56 50 45 40 36 32 29 26

30°

DPA2G9LP3FT120X3 (Data)

DPA 2’x 2’

0

5" (127 mm) 24" (610 mm)

500 60°

1000

5 6 7 8 9 10

24" (610 mm) 9 Cells

RCR 1 2 3 4

12 Cells 3014

C. U. 78 70 63 57 51 47 43 39 36 33

30°

DPA2G16LS26U120SO (Data)

DPA 2’x 2’

0

5" (127 mm) 500

24" (610 mm)

60°

24" (610 mm)

1000

16 Cells 1573 0°

34

30°

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 66 60 54 48 44 40 36 33 31 28


Recessed Luminaires Parabolic Application Data*

Reference Data Efficiency Spacing Ratio

66.2% 1.2

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

60.0W .88

FC VCP W/Sq Ft

57

89

0.9

8' x 10' (80 sq ft/luminaire) 47

90

0.8

72

1.2

Ordering Guide Type Cells Air Handling

9 12

Lamps qty/type

Exposed T-Grid DPA2G9LS26U DPA2G12LS26U

2-T8U6 2-T8U6

Slot-T or Concealed T DPA2T9LS26U DPA2T12LS26U

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

57

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

34

89

0.9

Basic catalogue number : 3� Deep Precision Contoured Preanodized Aluminum Parabolic Louver

RE835 lamp rated at 3000 lumens

Application Data*

Reference Data Efficiency Spacing Ratio

63.4% 1.4

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing

83.0W .92

FC VCP W/Sq Ft

50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

120

DPA2G9LS26U

79

85

1.3

8' x 10' (80 sq ft/luminaire) 65

86

1.0

64

1.8

Ordering Guide Type Cells Air Handling

9 12

SO

Voltage : 120 277 347

Lamps qty/type

Ballast : See page 34

Exposed T-Grid DPA2G9LP32U DPA2G12LP32U

3-T8U1.6 3-T8U1.6

Options : See page 34 Add appropriate suffix to catalogue number

Slot-T or Concealed T DPA2T9LP32U DPA2T12LP32U

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

80

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

48

85

1.3

RE835 lamp rated at 2900 lumens

Application Data*

Reference Data Efficiency Spacing Ratio

72.0% 1.5

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing

103.0W .90

FC VCP W/Sq Ft

50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

120

DPA2G9LP32U Basic catalogue number :

98

91

1.6

8' x 10' (80 sq ft/luminaire) 81

92

1.3

100 74

2.1

Ordering Guide Type Cells Air Handling

9 12

03

Voltage :

Lamps qty/type

Ballast :

Exposed T-Grid DPA2G9LP3FT DPA2G12LP3FT

3-TT5 3-TT5

Options :

Slot-T or Concealed T DPA2T9LP3FT DPA2T12LP3FT

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

62

91

1.6

Basic catalogue number :

RE835 lamp rated at 3150 lumens

Reference Data

Application Data*

Efficiency Spacing Ratio

Luminaire Spacing

61.6% 1.3

Electronic Ballast Input Watts (120V) Ballast Factor

60.0W .88

FC VCP W/Sq Ft

50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

120

DPA2G9LP3FT

53

95

0.9

8' x 10' (80 sq ft/luminaire) 44

96

0.8

85

1.2

Ordering Guide Type Cells Air Handling

16

X3

Voltage :

Lamps qty/type

Ballast :

Exposed T-Grid DPA2G16LS26U

2-T8U6

Options :

Slot-T or Concealed T DPA2T16LS26U

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

56

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

35

95

RE835 lamp rated at 3000 lumens

*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor.

0.9

DPA2G16LS26U Basic catalogue number :

120 Voltage :

SO Ballast :

Options :

35


Recessed Luminaires Parabolic

Paralyte 2448 2’ x 4’ (PLA) 3”Deep Cells • Air Return Luminaires PLA 2’x 4’

PLA2G12LS232120SO (Data)

0

RCR

5-1/2" (140 mm) 24" (610 mm)

1000

48" (1219 mm)

PARABOLICS

Paralyte 2’ x 4’ luminaires are highly efficient, more so than virtually any comparable parabolic luminaire because of the greater width of the optical chamber. Paralyte luminaries are suitable for a wide variety of applications, especially merchandising and showroom lighting where ceilings are high and maximum light output is required. 23" x 47" louver eliminates black reveal in standard grid ceilings and has only 1/4" reveal in slot or narrow grid ceilings. (NOT for continuous row mounting.) Features •2 lamp, 12 cell (78.9% efficient). •3 lamp, 18 cell (73.3% efficient). •Full 23" x 47" aluminum parabolic louver. •Low iridescence, semi-specular aluminum, standard. •Vertical grain louver eliminates reflected lamp image on cross baffle. •One luminaire fits 50 lay-in G type and Slot Grid type ceiling systems. •Only 5-1/2" deep housing. •Individual lamp compartments. •Spring-loaded latches. •Shipped with removable polyethylene dust guard to protect louver. •Captive bolt ballast mounting. •Capable of returning up to 300 CFM at .05 negative static pressure depending on ceiling system. •3” deep aluminum parabolic louver.

500

60°

1634

12 Cells ll 12

PLA 2’x 4’

C. U.

1 2

85 76

3 4

68 60

5 6

54 48

7 8

43 38

9 10

34 30

30°

PLA2G18LP332120O3 (Data)

0

RCR 1 2 3

5-1/2" (140 mm) 24" (610 mm)

1000

60°

48" (1219 mm) 2000

18 Cells

24 Cells

2444 0°

C. U. 79 71 64

4 5

58 52

6 7

46 42

8 9 10

37 34 30

30°

Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming T8: OC T8: SO T8: PS 3 LPB T8: O3 (not avail. in 347V) 4 LPB T8: O4 LPB : Number of lamps per ballast. Radio Interference Filter 120, 277 or 347 volt, 50 or 60 Hz. Suffix: R. Emergency Lighting System Suffix: O (e.g. PLA2G12LS232120SOO). Emergency battery pack with charger. (90 minutes at 15% of lumens for 1 lamp). Louver Finish Low iridescence semi-specular is standard. Consult factoy for other finishes. One Luminaire Fits All These Ceiling Types narrow grid system. slot grid. standard grid. two-directional concealed grid.

Hold-Down Clip

Automatic locking and adjustable leveling from outside or inside the luminaire.

36

Capable of returning up to 300 CFM at .05 negative static pressure depending on ceiling system.


Recessed Luminaires Parabolic Application Data*

Reference Data Efficiency Spacing Ratio

78.9% 1.6

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

62.0W .88

FC VCP W/Sq Ft

67

92

0.9

8' x 10' (80 sq ft/luminaire) 56

92

0.8

Ordering Guide Type Cells Air Return

12

Lamps Qty/Type 2-T8

Catalogue Number PLA2G12LS232

Not for continuous row mounting

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire) 65

78

1.2

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

36

99

0.9

120

PLA2G12LS232 Basic catalogue number : 3� Deep Precision Contoured Preanodized Aluminum Parabolic Louver

Application Data*

Reference Data Efficiency Spacing Ratio

73.3% 1.5

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

85.0W .88

FC VCP W/Sq Ft

94

89

1.3

8' x 10' (80 sq ft/luminaire) 78

90

1.1

Ordering Guide Type Cells Air Return

18 18

Voltage : 120 277 347

Lamps qty/type 3-T8 4-T8

SO Ballast : See page 36

Options : See page 36 Add appropriate suffix to catalogue number

Catalogue number PLA2G18LP332 PLA2G18LS432

Not for continuous row mounting.

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

93

77

1.8

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

55

97

1.3

PLA2G18LP332 Basic catalogue number :

120 Voltage :

03 Ballast :

Options :

Mounting Method

Narrow Grid System

Slot Grid

Standard Grid

*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

Two Directional Concealed Grid

37


Recessed Luminaires Parabolic

Paralyte 2424 2’ x 2’ (PLA) 3”Deep Cells • Air Return Luminaires PLA2G9LS26U120SO (Data)

PLA 2’x 2’

0

RCR

5-1/2" (140 mm)

500 60°

24" (610 mm) 1000

24" (610 mm)

PARABOLICS

Architecturally symmetric Paralyte 2’ x 2’ luminaires are the first choice for department stores, specialty shop and designer showroom lighting. Up to 3 TT5 type lamps or T8U1.6 lamps can be accommodated in this luminaire with 9 cell louvers for high light output. 23" x 23" louver eliminates black reveal in standard grid ceilings and has only 1/4" reveal in slot or narrow grid ceilings. (NOT for continuous row mounting.) Features •2U lamp, 9 cell (68.7% efficient). •9 cell 3 T8U1.6 lamps (72.6% efficient). 9 cell 3 TT5 lamps (72.8% efficient). Either unit can provide the same lighting levels as an 18 cell, 3 lamps 2' x 4' parabolic without additional units. •Full 23" square aluminum parabolic louver. •Non-directional in appearance. •Low-iridescence, semi-specular aluminum, standard. •3-1/8" deep louver. •Vertical grain on louver eliminates reflected lamp image on cross baffle. •One luminaire fits 50 lay-in Grid and Slot Grid type ceiling systems. •Only 5-1/2" deep housing. •Automatic engaging hold-down clips. •Individual lamp compartments. •Black exterior finish for cooler ballast operation. •Spring-loaded latches. •Shipped with removable polyethylene dust guard to protect Louver. Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming T8: OC 3 LPB T8: O3 T8: PS T8: SO (not avail. in 347V) LPB : Number of lamps per ballast.

9 Cells

1482 0°

3 4

58 51

5 6

46 42

7 8

38 34

9 10

32 29

PLA2G9LP32U120O3 (Data)

PLA 2’x 2’ T8U1.6: 5-1/2" (140 mm)

0

24" (610 mm) 1000

60°

TT5: 24" (610 mm)

2000

9 Cells 2470 0°

RCR 1 2 3

C. U. 78 71 64

4 5

57 51

6 7

46 42

8 9 10

37 33 30

30°

PLA2G16LS26U120SO (Data)

PLA 2’x 2’

0

5-1/2" (140 mm)

500

60°

24" (610 mm)

24" (610 mm) 16 Cells

1389 0°

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 65 59 53 48 43 39 35 32 28 26

30°

Hold-Down Clip

Automatic locking and adjustable leveling from outside or inside the luminaire.

38

73 65

30°

1000

Radio Interference Filter 120, 277 or 347 volt, 50 or 60 Hz. Suffix: R. Emergency Lighting System Consult CFI Fluorescent Representative. Louver Finish Low iridescence semi-specular is standard. Consult factoy for other finishes. One Luminaire Fits All These Ceiling Types narrow grid system. slot grid. standard grid. two-directional concealed grid.

C. U.

1 2

Capable of returning up to 175 CFM at .05 negative static pressure depending on ceiling system.


Recessed Luminaires Parabolic Application Data*

Reference Data Efficiency Spacing Ratio

68.7% 1.3

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

60.0W .88

FC VCP W/Sq Ft

59

85

0.9

8' x 10' (80 sq ft/luminaire) 49

86

0.8

Ordering Guide Type Cells Air Return

9

Lamps qty/type 2-T8U6

Catalogue number PLA2G9LS26U

Not for continuous row mounting.

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

58

67

1.2

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

35

85

0.9

Basic catalogue number : 3" Deep Precision Contoured Preanodized Aluminum Parabolic Louver

RE835 lamp rated at 3000 lumens

Application Data*

Reference Data Efficiency Spacing Ratio

72.6% 1.5

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

83.0W .92

FC VCP W/Sq Ft

91

79

1.3

8' x 10' (80 sq ft/luminaire) 76

80

1.0

120

PLA2G9LS26U

Ordering Guide Type Cells Air Return

9

Voltage : 120 277 347

Lamps qty/type 3-T8U1.6

SO Ballast : See page 38

Options : See page 38 Add appropriate suffix to catalogue number

Catalogue number PLA2G9LP32U

Not for continuous row mounting.

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

91

60

1.8

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

55

79

1.3

120

PLA2G9LP32U Basic catalogue number :

Voltage :

03 Ballast :

Options :

RE835 lamp rated at 2900 lumens

Application Data*

Reference Data Efficiency Spacing Ratio

59.9% 1.4

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

60.0W .88

FC VCP W/Sq Ft

51

92

0.9

8' x 10' (80 sq ft/luminaire) 43

93

0.8

Ordering Guide Type Cells Air Return

16

Lamps qty/type 2-T8U6

Catalogue number PLA2G16LS26U

Not for continuous row mounting.

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

53

81

1.2

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

33

92

0.9

PLA2G16LS26U Basic catalogue number :

120 Voltage :

SO Ballast :

Options :

RE835 lamp rated at 3000 lumens

Mounting Method

Narrow Grid System

Slot Grid

Standard Grid

*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor.

Two Directional Concealed Grid

39


Recessed Luminaires Parabolic

Lytecel - Individual 9”x 48” (LIA, LIS) Air Handling / Static Luminaires LIA 9“ x 48“

LIA9G12PR132120SO (Data) Lytecel 9 Continuous Louver

6-1/8" (156mm)

6-1/2" (165mm) 9" (229mm)

PARABOLICS

Features • Narrow 6-1/2" wide louver openings • Meets IES RP1 for lighting VDT areas. • 65.2% efficient T8-1 light. • 61.0% efficient T8-2 light. • 1.5 and 1.4 spacing mounting ratio. • Specular, low iridescence, pre-anodized aluminum louver. • Vertical grain on louver eliminates reflected lamp image on cross baffle. • Louver frame with positive light stop. • Spring loaded latches (self centering). • Reversible louver hinging. • Louver has protective dust guard. • Only 6-1/8" deep body. • Black housing exterior for cooler ballast operating temperature. • Turned-in edges for safe handling. • Air closure strips (optional).

Options pages 150-156 Ballast Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. 120SO <20THD <10THD Electronic T8 SO* HI* LOL T8 Dimming PS – *Instant Start Consult factory for other wattages. Electrical/Wiring Options For special wiring, fusing, electronic dimming ballasts, consult factory. Fusing Internal fast-blow fusing. SUFFIX: F. Radio Interference Filter 120 or 277 volt, 50 or 60 Hz. One per fixture. SUFFIX: R. Air Closure Strips: Suffix: S (factory installed), Cat no. ACS4 (Field installed). Drywall Kit Order catalog number FK99X4 with “G” type fixtures for drywall of plaster ceilings. This FK99X4 kit is only for Lytecel individual mounts.

0

12 Cells 750 60

RCR 1 2 3 4 5 6 7

1500

2250 0

30

8 9

46 43

10

41

LIA9G12PR232120SO (Data)

LIA 9“ x 48“

Lytecel 8 Continuous Louver

6-1/8" (156mm)

6-1/2" (165mm) 9" (229mm)

0

12 Cells 750 60

1500

2250 0

40

C. U. 73 69 64 60 56 53 49

30

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 69 65 60 57 53 50 46 44 41 39


Recessed Luminaires Parabolic Application Data*

Reference Data Efficiency Spacing Ratio

65.2% 1.5

LUMINOUS INTENSITY 55° 65° 75° 85°

47cd 5cd 3cd 2cd

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing

FC

W/Sq Ft

8' x 8' (64 sq ft/luminaire)

25

0.45

8' x 10' (80 sq ft/luminaire)

20.9

0.45

37.4

1.08

50' x 70' x 8.5' Space

Ordering Guide Type Cells Static Air Handling

12 12

Lamps qty/type

Exposed T-Grid

Exposed Slot-T Concealed T-Grid

1-T8 1-T8

LIS9G12PR132 LIA9G12PR132

LIS9T12PR132 LIA9T12PR132

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

8' x 8' x 8.5' Cubicle/60" Partition 31.0W 0.88

8' x 8' (64 sq ft/luminaire)

28.8

1.08

120

LIA9G12PR132 Basic catalogue number : Lytecell Individual 9“ x 48“

Voltage : 120 277 347 UNV

SO Ballast : See page 40

Options : See page 40 Add appropriate suffix to catalogue number

* For low iridescence semi-spectacular louver finish order LIA9G12LR132

Reference Data

Application Data*

Efficiency Spacing Ratio

Luminaire Spacing

61.0% 1.4

FC

W/Sq Ft

50' x 70' x 8.5' Space

LUMINOUS INTENSITY

8' x 8' (64 sq ft/luminaire)

30.4

0.56

55° 65° 75° 85°

8' x 10' (80 sq ft/luminaire)

26

0.56

21.3

0.51

27.2

0.87

90cd 12cd 6cd 4cd

Electronic Ballast Input Watts (120V) Ballast Factor

Ordering Guide Type Cells Static Air Handling

12 12

Lamp qty/type

Exposed T-Grid

Exposed Slot-T Concealed T-Grid

2-T8 2-T8

LIS9G12PR232 LIA9G12PR232

LIS9T12PR232 LIA9T12PR232

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire) 12' x 16' x 8.5' Space

62.0W 0.88

6' x 8' (48 sq ft/luminaire)

LIS9G12PR232 Basic catalogue number :

120 Voltage :

SO Ballast :

Options :

* For low iridescence semi-spectacular louver finish order LIA9G12LR132

*Average Footcandles Maintained Total LLF=BF (.88) x .85= .75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor. RE835 lamp rated at 3000 lumens.

41


Recessed Luminaires Parabolic

Lytecel - Continuous Row 9“x 48”, 8”x 48” (LCA, LCS) Air Handling / Static Luminaires Lytecel 9 Continuous

LCA9G12PR232120SO (Data) Lytecel 9 Continuous Louver 6-1/8" (156mm)

6-1/2" (165mm) 9" (229mm)

6-1/8" (156mm)

Lytecel Continuous is a unique versatile narrow recessed linear parabolic that can be used with a variety of ceiling systems to create uninterrupted lines of light with a continuous louver appearance for the entire row.

PARABOLICS

6-1/2" (165mm) 9" (229mm)

Lytecel will provide illumunination that meets IES RP-1 requirements for lighting VDT areas at low energy cost. Features • Narrow 6-1/2" wide louver. • 48" long louver gives an uninterrupted louver appearance when row mounted. • Meets IES RP1 for lighting VDT areas. • 61.0% efficient (T8) 2 light. • 65.2% efficient (T8) 1-light. • 1.5 and 1.4 spacing mounting ratio. • Specular, low iridescence, pre-anodized aluminum louver. • Vertical grain on cross blades eliminates reflected lamp image. • Spring loaded latches (self centering). • Reversible louver hinging. • Louver has protective dust guard. • Only 6-1/8" deep body. • Black housing exterior for cooler ballast operating temperature. • Turned-in edges for safe handling. • Air closure strips (optional). • 8” wide model only available in static. Options pages 150-156 Ballast Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. 120SO <20THD <10THD Electronic T8 SO* HI* LOL T8 Dimming PS – *Instant Start Consult factory for other wattages. Electrical/Wiring Options For special wiring, fusing, electronic dimming ballasts, consult factory. Fusing Internal fast-blow fusing. SUFFIX: F. Radio Interference Filter 120 or 277 volt, 50 or 60 Hz. One per fixture. SUFFIX: R. Air Closure Strips: Suffix: S (factory installed), Cat no. ACS4 (Field installed).

42

12 Cells

Lytecel 9 or Lytecel 8 0

0

400

750 60

800

60

1500

1200

2250 0

30

0

1 Lamp

30

2 Lamp

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 69 65 60 57 53 50 46 44 41 39

LCS8G12PR232120SO (Data)

Lytecel 8 Continous

Lytecel 8 Continuous Louver 6-1/8" (156mm)

6-1/2" (165mm) T-Type 8" (203mm)

6-1/8" (156mm)

6-1/2" (165mm) T-Type 8" (203mm)

12 Cells


Recessed Luminaires Parabolic Application Data*

Reference Data Efficiency Spacing Ratio

65.2% 1.5

LUMINOUS INTENSITY 55° 65° 75° 85°

47cd 5cd 3cd 2cd

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing

FC VCP W/Sq Ft

50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

30.4

0.56

Ordering Guide Type Cells Static Air Handling

8' x 10' (80 sq ft/luminaire) 12' x 16' x 8.5' Space

12 12 12 12

Lamps qty/type

Exposed T-Grid

Exposed Slot-T Concealed T-Grid

1-T8 2-T8 1-T8 2-T8

LCS9G12PR132 LCS9G12PR232 LCA9G12PR132 LCA9G12PR232

LCS9T12PR132 LCA9T12PR232 LCA9T12PR132 LCA9T12PR232

Each fixture is 4' in length and can be run in any desired row length of 4' increments.

6' x 8' (48 sq ft/luminaire) 8' x 8' x 8.5' Cubicle/60" Partition

31.0W 0.88

120

LCA9G12PR232

8' x 8' (64 sq ft/luminaire)

Basic catalogue number : Lytecell 9 Continuous

SO

Voltage : 120 277 347 UNV

Ballast : See page 42

Options : See page 42 Add appropriate suffix to catalogue number

* For low Iridescence Semi-Spectacular louver finish order LCA9G12LR132

Reference Data Efficiency Spacing Ratio

Application Data* 61.0% 1.4

LUMINOUS INTENSITY 55° 65° 75° 85°

90cd 12cd 6cd 4cd

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire) 8' x 10' (80 sq ft/luminaire) 12' x 16' x 8.5' Space

FC VCP W/Sq Ft

Ordering Guide Type Cells Lamp qty/ type Static Static

12 12

2-T8 1-T8

15/16 Grid

9/16 Grid

Exposed Slot-T or Concealed T

LCS8G12PR232 LCS8N12PR232 LCS8T12PR232 LCS8G12PR132 LCS8N12PR132 LCS8T12PR132

Each fixture is 4' in length and can be run in any desired row length of 4' increments.

6' x 8' (48 sq ft/luminaire) 12' x 16' x 8.5' Space

62.0W 0.88

6' x 8' (48 sq ft/luminaire)

LCS8G12PR232 Basic catalogue number :

120 Voltage :

SO Ballast :

Options :

* For low Iridescence Semi-Spectacular louver finish order LCS8G12LR132

*Average Footcandles Maintained Total LLF=BF (.88) x .85= .75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor. RE835 lamp rated at 3000 lumens.

43


Recessed Luminaires Parabolic

Deepcel 20” x 60”, 20” x 48” (DDA, DQA) Air Handling/Static Luminaire DDA5G27LL232120SO (Data)

DDA 20” x 60”

6-1/2" (165mm) 0

RCR

250

15-5/8" (397mm)

750

20" (508mm)

60° 1239

60" (1525 mm)

40" (1016 mm)

Full length air slots and one-piece faceplate create clean lines and attractive ceiling appearance. The precise fitting 3” deep louver provides good glare control, while maintaining luminaire efficiency of 66.4% (12-cell, 2-T8).

3 4

52 46

5 6

41 36

7 8

32 28

9 10

24 21

30°

PARABOLICS

DDA5G12LL232120SO (Data) 6-1/2" (165mm) 15-5/8" (397mm)

0

500 60°

20" (508mm) 1000

60" (1525 mm)

40" (1016 mm)

1535

Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming T8: OC T8: SO T8: PS 3 LPB T8: 03 For T12 lamp see page 151. LPB : Number of lamps per ballast. Drywall Kit For plaster frames, order Cat. No.: FK920X5 (20” x 60”), FK920X4 (20” x 48”). Radio Interference Filter 120, 277 or 347 volt, 50 or 60 Hz. Suffix: R. Emergency Lighting System Suffix: O (e.g. DDA5G27LL232120OCO). Emergency battery pack with charger. (90 minutes at 15% of lumens for 1 lamp). Louver Finish Low iridescence semi-specular is standard. Static For static luminaires, replace A in the basic catalogue number by S.

67 59

27 Cells

DDA 20” x 60”

Features •Only 6-1/2” deep housing. •One-piece faceplate. •Side-mounted ballast cover for cooler ballast operation. •Contoured ballast cover for maximum light efficiency. •Double-hemmed edge along louver opening eliminates light leaks and provides maximum strength. •Full-length air slot with right angle stiffener for maximum rigidity and no slot interference. •Heavy-gauge faceplate will not distort during transport and installation. •Also available for metric ceiling systems, consult factory. •DQA is a full width 20” x 48” Parabolic luminaire.

C. U.

1 2

RCR 1 2 3

C. U. 72 65 58

4 5

52 47

6 7

42 38

8 9 10

34 31 28

30°

12 Cells

DDA 20” x 60”

DDA5G18LL232120SO (Data) 6-1/2" (165mm) 15-5/8" (397mm)

0

500 60°

20" (508mm) 1131

60" (1525 mm)

40" (1016 mm)

1500

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 66 60 54 48 43 39 35 31 28 25

30°

18 Cells

DQA 20” x 48”

DQA5G29LS232120SO (Data)

0

5-1/2" (140 mm) 500

16" (406 mm) 20" (508 mm)

1000

60°

1386

48" (1219 mm)

Double-hemmed edge along louver opening for flat surface with no light leaks.

44

40" (1016 mm) 0°

18 Cells

30°

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 71 63 56 50 45 40 36 33 30 28


Recessed Luminaires Parabolic Application Data*

Reference Data Efficiency Spacing Ratio

66.3% 2.0

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing 50' x 70' x 8.5' Space 8' x 8 ' (64 sq ft/luminaire)

60.0W .88

FC VCP W/Sq Ft

Ordering Guide Type Cells Air Handling

57

84

0.9

8' x 10' (80 sq ft/luminaire) 45

84

0.7

83

1.2

27 27

Lamps qty/type 2-T8 3-T8

Catalogue number DDA5G27LL232 DDA5G27LL332

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

Application Data*

Reference Data Efficiency Spacing Ratio

66.4% 1.4

Electronic Ballast Input Watts (120V) Ballast Factor

52

Luminaire Spacing 50' x 70' x 8.5' Space

120 Voltage : 120 277 347

Ordering Guide Type Cells Air Handling

58

87

0.9

8' x 10' (80 sq ft/luminaire) 46

87

0.7

78

1.2

8' x 8' (64 sq ft/luminaire) 60.0W .88

FC VCP W/Sq Ft

DDA5G27LL232 Basic catalogue number : 3" Deep Precision Contoured Preanodized Aluminum Parabolic Louver

12 12

Lamps qty/type 2-T8 3-T8

SO Ballast : See page 44

Options : See page 44

Catalogue number DDA5G12LL232 DDA5G12LL332

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

52

DDA5G12LL232 Basic catalogue number :

Application Data*

Reference Data Efficiency Spacing Ratio

61.1% 1.8

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing 50' x 70' x 8.5' Space

Ordering Guide Type Cells Air Handling

55

89

0.9

8' x 10' (80 sq ft/luminaire) 41

89

0.7

81

1.2

8' x 8' (64 sq ft/luminaire) 60.0W .88

FC VCP W/Sq Ft

18 18

120

SO

Voltage :

Ballast :

Lamps qty/type 2-T8 3-T8

Options :

Catalogue number DDA5G18LL232 DDA5G18LL332

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

49

DDA5G18LL332 Basic catalogue number :

Reference Data

Application Data

Efficiency Spacing Ratio

Luminaire Spacing

65.8% 2.0

Electronic Ballast Input Watts (120V) Ballast Factor

60.0W .88

FC

W/Sq Ft

8' x 8' (64 sq ft/luminaire)

58

.9

8' x 10' (80 sq ft/luminaire)

40

.7

51

1.2

50' x 70' x 8.5' Space

Ordering Guide Type Cells Air Handling Air Handling

18 18

120

03

Voltage :

Ballast :

Lamps qty/type 2-T8 2-T8

Options :

Catalogue number DQA5G29LS232 DQA5G29PR232

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

DQA5G29PR232 Basic catalogue number :

*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

120 Voltage :

SO Ballast :

45


Recessed Luminaires Parabolic

Parabaffle 2’ x 2’ & 2’ x 4’ (MPA) 1 1/2”Deep Cells • Air Handling/Static Luminaires MPA 2’ x 2’

MPA2G36LS26U120SO (Data)

0

RCR

5" (127 mm) 500

24" (610 mm)

60°

24" (610 mm) 1000

36 36 Cells C ll

PARABOLICS

Parabaffle’s 3-1/2" x 3-1/2" cell size creates the illusion of greater shielding and smaller overall size than large cell parabolics. This luminaire is only 5" deep, allowing it to fit in restricted plenums. It is low in brightness and versions are available that meet IES RP-1 recommended (basic) practice for VDT areas.

MPA 2’ x 2’

Features •3-1/2" x 3-1/2" cell (2' x 4' and 2' x 2') aluminum parabolic louver, 1-1/2" deep. •Built-in hold-down clips (2’ x 4’ & 2’ x 2’) •5" deep body. (2'x 4', 2' x 2') “T” types 5-1/4". •Captive bolt ballast mounting. •1-1/2” deep aluminum parabolic louver. Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming 40W TT5: BX 40W TT5: SB 40W TT5: PB T8: OC 50W TT5: BE T8: PS 55W TT5: BF (not avail. in 347V) 3 LPB 40W TT5: X3 T8: SO 3 LPB T8: O3 4 LPB T8: O4 LPB : Number of lamps per ballast. Drywall Kit For plaster frames, order Cat. No.: FK92X4 (2’ x 4’), FK92X2 (2’ x 2’). Radio Interference Filter 120, 277 or 347 volt, 50 or 60 Hz. Suffix: R. Emergency Lighting System Suffix: O (e.g. MPA2G78LS23212003O). Emergency battery pack with charger. (90 minutes at 15% of lumens for 1 lamp). For 2’ x 2’, consult CFI Fluorescent Representative. Louver Finish Low iridescence semi-specular is standard. Air Pattern Control and Air Slot Closure For horizontal and vertical air supply and to balance return air. Suffix: S. (MPA only) Static For static luminaires, replace A in the basic catalogue number by S.

46

1270

C. U.

1 2

60 54

3 4

49 44

5 6

39 35

7 8

32 28

9 10

25 23

30°

MPA2G36LP32U120O3 (Data)

0

5" (127 mm) 24" (610 mm)

500 60°

1000

24" (610 mm) 36Cells Cells 36 2284 0°

MPA 2’ x 4’

RCR 1 2 3

C. U. 60 54 49

4 5

45 40

6 7

37 33

8 9 10

30 27 24

30°

MPA2G78LS332120O3 (Data)

5" (127 mm) 24" (610 mm)

0

500

5" 1000 (127 mm)

60°

24" (610 mm)

48" (1219 mm) 78 Cells Cells 78

1968

30°

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 67 60 54 49 44 40 35 32 28 25


Recessed Luminaires Parabolic Application Data*

Reference Data Efficiency Spacing Ratio

58.2% 1.1

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

60.0W .88

FC VCP W/Sq Ft

48

93

0.9

8' x 10' (80 sq ft/luminaire) 39

94

0.8

80

1.2

Ordering Guide Type Luminaire Cells size Air 2x2 Handling

36

Lamps qty/type 2-T8U6

Exposed Exposed Slot-T or T-Grid Concealed T-Grid MPA2G36LS26U MPA2T36LS26U

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

48

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

29

93

0.9

Basic catalogue number : Parabaffle Recessed Parabolic

RE835 lamp rated at 3000 lumens

Application Data*

Reference Data Efficiency Spacing Ratio

54.8% 1.4

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

83.0W .92

FC VCP W/Sq Ft

70

92

1.3

8' x 10' (80 sq ft/luminaire) 58

93

1.0

80

1.8

120

MPA2G36LS26U

Ordering Guide Type Luminaire Cells size Air 2x2 Handling 2 x 2

36 36

SO

Voltage : 120 277 347

Lamps qty/type 3-T8U1.6 3-TT5

Ballast : See page 46

Exposed T-Grid MPA2G36LS32U MPA2G36LS3FT

Options : See page 46 Add appropriate suffix to catalogue number

Exposed Slot-T or Concealed T-Grid MPA2T36LS32U MPA2T36LS3FT

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

73

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

46

92

1.3

120

MPA2G36LS32U Basic catalogue number :

03

Voltage :

Ballast :

Options :

RE835 lamp rated at 2900 lumens

Application Data*

Reference Data Efficiency Spacing Ratio

62.6% 1.6

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

85.0W .88

FC VCP W/Sq Ft

80

95

1.3

8' x 10' (80 sq ft/luminaire) 66

96

1.1

Ordering Guide Type Luminaire Cells size Air 2x4 Handling 2 x 4* 2x4

78 78 78

Lamps qty/type 3-T8 3-T8 4-T8

Exposed T-Grid MPA2G78LS332 MPA2G78PP332 MPA2G78LS432

Exposed Slot-T or Concealed T-Grid MPA2T78LS332 MPA2T78PP332 MPA2T78LS432

*Meets IES RP-1 recommended (basic) for VDT applications.

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

80

83

1.8

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

46

97

RE835 lamp rated at 3000 lumens

*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor.

1.3

MPA2G78LS432 Basic catalogue number :

120 Voltage :

04 Ballast :

Options :

47


Recessed Luminaires Lens and Asymmetric

Prismalyte Plus 1’x 4’, 2’x 2’, 2’x 4’ (PRA) Premium Specification Grade Lens • Air Handling/Static Luminaires PRA1GRFVA232120SO (Data)

PRA 1’ x 4’

0

RCR 500

4-3/4" (121 mm) 1000

12" (305 mm)

LENS RECESSED

Prismalyte Plus luminaires are top of the line air handling lensed fluorescent luminaires with floating door appearance, regressed aluminum doors and black painted housing for optimum lamp and ballast operation. Luminaires are a full 5" deep for minimal lamp image demanded in a high specification troffer.

1681 0°

3 4

55 49

5 6

44 40

7 8

36 32

9 10

29 27

30°

0

RCR

5" (127 mm)

500

60°

24" (610 mm) 1000

1464 0°i

PRA 2’ x 2’

C. U.

1 2

64 57

3 4 5 6 7 8 9 10

51 46 42 38 34 31 28 25

30°

PRA2GRFVA32U120O3 (Data)

0

5" (127 mm)

60°

1000

24" (610 mm)

2000 2465 0°

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 66 59 53 47 43 39 36 33 30 28

30°

PRA2GRFVA432120O4 (Data)

PRA 2’ x 4’

0

5" (127 mm) 1000

24" (610 mm)

60°

5" (127 mm)

2000

24" (610 mm) 5" (127 mm) 24" (610 mm)

3685 0°

48

68 61

PRA2GRFVA26U120SO (Data)

PRA 2’ x 2’

Features •5" deep. (2' x 4') (2' x 2'). •2-31/32” lamp to lens for better lamp obscuration (2’ x 2’, 2’ x 4’). •4-3/4" deep. (1' x 4' model for exposed slot-T or consealted T-grid) •One-piece housing is embossed construction for added strength. •Efficiency 76.7%, 4 light. •Black housing exterior for cooler ballast operating temperature. •Turned-up edges for safe handling. •Built-in hold-down clips (2'x2'/2'x4'). •Perfectly uniform four side reveal with black finish for floating effect. •Door jamb finished black on four sides for positive light stop. •Spring-loaded latches. Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming 40W TT5: BX 40W TT5: SB 40WTT5: PB T8: OC 50W TT5: BE T8: PS 55W TT5: BF (not avail. in 347V) 3 LPB 40W TT5: X3 1 or 2 LPB T8: SO 3 LPB T8: O3 4 LPB T8: O4 For T12 lamp see page 151. LPB : Number of lamps per ballast. Drywall Kit For plaster frames, order Cat. No.: FK92X4 (2’ x 4’), FK92X2 (2’ x 2’), FK91X4 (1’ x 4’). Internal Fusing Consult your CFI Fluorescent representative. Radio Interference Filter 120, 277 or 347 volt, 50 or 60Hz. Suffix: R. Emergency Lighting System Suffix: O (e.g. PRA1GRFVA232120SOO). Emergency battery pack with charger. (90 minutes at 15% of lumens for 1 lamp). For 2’ x 2’ consult CFI Fluorescent Representative. Special Lens - VA lens pattern 12 prismatic virgin acrylic is standard. For other available lenses, see page 155. Air Pattern Control and Air Slot Closure For horizontal and vertical supply and to balance return air. Suffix: S. Static For static luminaires, replace PRA in the basic catalogue number by PRS.

60°

C. U.

1 2

30°

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 81 71 63 57 51 46 42 39 36 33


Recessed Luminaires Lens Application Data*

Reference Data Efficiency Spacing Ratio

63.7% 1.3

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

60.0W .88

FC VCP W/Sq Ft

50

59

0.9

8' x 10' (80 sq ft/luminaire) 41

59

0.8

84

1.2

Ordering Guide Type Luminaire size Air Handling

1x4 1x4

Lamps qty/type

Exposed T-Grid PRA1GRFVA132 PRA1GRFVA232

1-T8 2-T8

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

49

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

30

59

Basic catalogue number : Floating Lens Frame Recessed Fluorescent Troffer

RE835 lamp rated at 3000 lumens

Application Data*

Reference Data Efficiency Spacing Ratio

59.8% 1.4

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing

60.0W .88

FC VCP W/Sq Ft

50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

120

PRA1GRFVA232

OC

0.9

47

66

0.9

8' x 10' (80 sq ft/luminaire) 39

66

0.8

85

1.2

Voltage : 120 277 347

Ordering Guide Type Luminaire Lamps size qty/type Air Handling

2x2

Ballast : See page 48

Exposed T-Grid PRA2GRFVA26U

2-T8U6

Options : See page 48 Add appropriate suffix to catalogue number

Exposed Slot-T or Concealed T-Grid PRA2TRFVA26U

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

46

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

29

66

0.9

120

PRA2GRFVA26U Basic catalogue number :

SO

Voltage :

Ballast :

Options :

RE835 lamp rated at 3000 lumens

Application Data*

Reference Data Efficiency Spacing Ratio

62.2% 1.3

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

83.0W .92

FC VCP W/Sq Ft

70

57

1.3

8' x 10' (80 sq ft/luminaire) 59

58

1.0

Ordering Guide Type Luminaire Lamps size qty/type Air Handling

2x2 2x2

Exposed T-Grid PRA2GRFVA32U PRA2GRFVA3FT

3-T8U1.6 3-TT5

Exposed Slot-T or Concealed T-Grid PRA2TRFVA32U PRA2TRFVA3FT

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire) 71

78

1.8

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

46

57

1.3

120

PRA2GRFVA32U Basic catalogue number :

03

Voltage :

Ballast :

Options :

RE835 lamp rated at 2900 lumens

Reference Data

Application Data*

Efficiency Spacing Ratio

Luminaire Spacing

76.7% 1.3

Electronic Ballast Input Watts (120V) Ballast Factor

50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

112.0W .88

FC VCP W/Sq Ft

118 64

8' x 10' (80 sq ft/luminaire) 98

1.8

64

1.4

117 81

2.3

Ordering Guide Type Luminaire Lamps size qty/type Air Handling

2x4 2x4 2x4

Exposed T-Grid PRA2GRFVA232 PRA2GRFVA332 PRA2GRFVA432

2-T8 3-T8 4-T8

Exposed Slot-T or Concealed T-Grid PRA2TRFVA232 PRA2TRFVA332 PRA2TRFVA432

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

70

64

1.8

PRA2GRFVA432 Basic catalogue number :

120 Voltage :

04 Ballast :

Options :

RE835 lamp rated at 3000 lumens

*Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor.

49


Recessed Luminaires Lens and Asymmetric

SpecPlus 1’x 4’, 2’x 2’, 2’x 4’ (SPS) Premium Specification Grade Lens • Static Fluorescent Luminaires SPS1GFSVA232120SO (Data)

SPS 1’ x 4’

0

RCR 500

4-3/4" (121 mm)

60°

12" (305 mm) 1000

LENS RECESSED

SpecPlus offers higher quality and more features than any other specification grade troffer. Full 5" deep body, built-in clips with positive clamping by screws, easy re-lamping, and an extraordinary 1000 sq. inch lens area puts this luminaire in the lead on performance, safety and ease of maintenance.

1681 0°

Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming 40W TT5: BX 40W TT5: SB 40W TT5: PB T8: OC 50W TT5: BE T8: PS 55W TT5: BF (not avail. in 347V) 3 LPB 40W TT5: X3 1 or 2 LPB T8: SO 3 LPB T8: O3 4 LPB T8: O4 For T12 lamp see page 151. LPB : Number of lamps per ballast. Drywall Kit For plaster frames, order Cat. No.: FK92X4 (2’ x 4’), FK92X2 (2’ x 2’), FK91X4 (1’ x 4’). Internal Fusing Consult your CFI Fluorescent representative. Radio Interference Filter 120, 277 or 347 volt, 50 or 60Hz. Suffix: R. Emergency Lighting System Suffix: O (e.g. SPS1GFSVA232120SOO). Emergency battery pack with charger. (90 minutes at 15% of lumens for 1 lamp). Special Lens - VA lens pattern 12 prismatic virgin acrylic is standard. For other available lenses, see page 155. Door Option - FS Flat steel door is standard. For regressed aluminum door frame, replace FS by RA. For flush aluminum door frame, replace FS by FA. FS

Flush Steel (Standard)

RA

Regressed Aluminum

55 50

5 6

45 41

7 8

37 33

9 10

30 27

30°

RCR 500 60°

5" (127 mm) 1000

24" (610 mm)

1567 0°

SPS 2’ x 2’

C. U.

1 2

74 65

3 4 5 6 7 8 9 10

58 52 47 42 38 35 32 30

30°

SPS2GFSVA32U120O3 (Data)

0

500

5" (127 mm)

60° 1000

24" (610 mm)

2125 0°

SPS 2’ x 4’

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 62 56 51 46 42 38 35 35 29 27

30°

SPS2GFSVA432120O4 (Data)

0

5" (127 mm) 1000

24" (610 mm)

60° 2000

24" (610 mm) 5" (127 mm) 3690

24" (610 mm) 0°

50

3 4

0

5" (127 mm)

SPS, AA, AAS and ELS fixtures all have these door frame options.

69 62

SPS2GFSVA26U120SO (Data)

SPS 2’ x 2’

Features •Full 5" deep (2’ x 2’ and 2’ x 4’). •2-31/32" lamp to lens for better lamp obscuration. •Efficiency 81.2%, (4 light). •Built-in hold-down clips (2’ x 2’ / 2’ x 4’). •One-piece housing is embossed for added strength. •Smoothly-turned edges for safe handling. •Captive bolt ballast mounting. •Reversible slim-line lens frames with 1,000 square inch lens area (2’ x 4’). •Door jamb with integral positive light stop. •Mitered lens frames, flange and trim. •Cam-action latches.

C. U.

1 2

30°

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 85 75 67 60 54 49 44 40 37 34


Recessed Luminaires Lens Application Data*

Reference Data Efficiency Spacing Ratio

64.6% 1.3

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

62.0W .88

FC VCP W/Sq Ft

Ordering Guide Type Luminaire size Static

50

57

0.9

8' x 10' (80 sq ft/luminaire) 42

57

0.8

85

1.2

1x4 1x4

Lamps qty/type

Exposed T-Grid SPS1GFSVA132 SPS1GFSVA232

1-T8 2-T8

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

50

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

31

57

0.9

SPS1GFSVA232 Basic catalogue number : Lens Frame Recessed Fluorescent Troffer

Application Data*

Reference Data Efficiency Spacing Ratio

70.5% 1.3

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

60.0W .88

FC VCP W/Sq Ft

Ordering Guide Type Luminaire size Static

53

56

0.85

8' x 10' (80 sq ft/luminaire) 44

56

0.68

80

1.1

2x2

120 Voltage : 120 277 347

SO Ballast : See page 50

Lamps qty/type

Options : See page 50 Add appropriate suffix to catalogue number

Exposed T-Grid SPS2GFSVA26U

2-T8U6

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

51

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

33

56

0.85

SPS2GFSVA26U Basic catalogue number :

Application Data*

Reference Data Efficiency Spacing Ratio

57.9% 1.2

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

83.0W .88

FC VCP W/Sq Ft

Ordering Guide Type Luminaire size Static

67

52

1.3

8' x 10' (80 sq ft/luminaire) 54

53

1.0

77

1.8

2x2 2x2

120 Voltage :

SO Ballast :

Lamps qty/type

Options :

Exposed T-Grid SPS2GFSVA32U SPS2GFSVA3FT

3-T8U1.6 3-TT5

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

64

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

41

52

1.3

SPS2GFSVA32U Basic catalogue number :

Reference Data

Application Data*

Efficiency Spacing Ratio

Luminaire Spacing

81.2% 1.3

Electronic Ballast Input Watts (120V) Ballast Factor

50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

112.0W .88

FC VCP W/Sq Ft

Ordering Guide Type Luminaire size Static

125 60

1.8

8' x 10' (80 sq ft/luminaire) 103 60

1.4

2x4 2x4 2x4

120 Voltage :

03 Ballast :

Lamps qty/type

Options :

Exposed T-Grid SPS2GFSVA232 SPS2GFSVA332 SPS2GFSVA432

2-T8 3-T8 4-T8

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

114 81

2.3

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

74

96

1.8

SPS2GFSVA432 Basic catalogue number :

*Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

120 Voltage :

04 Ballast :

Options :

51


Recessed Luminaires Lens

SpecTroffer 1’x 4’, 2’x 4’ (SQS) Specification Grade Shallow Design Troffer • Static Luminaires SQS2GFSVA232120SO (Data)

SQS 2’ x 4’

0

4" (102mm)

RCR 1 500

24" (610mm)

60° 1000

48" (1220mm)

LENS RECESSED

Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming T8: OC T8: SO T8: PS 3 LPB T8: O3 (not avail. in 347V) 4 LPB T8: O4 For T12 lamp see page 151. LPB : Number of lamps per ballast. Drywall Kit For plaster frames, order Cat. No.: FK92X4 (2’ x 4’). Internal Fusing Consult your CFI Fluorescent representative. Radio Interference Filter 120, 277 or 347 volt, 50 or 60Hz. Suffix: R. Emergency Lighting System Suffix: O (e.g. SQS2GFSVA232120SOO).

1797 0°

4" (102mm)

4" (102mm)

1000 60°

2000

48" (1220mm)

2626

Recessed Open Reflector

550

1100

52

50

6 7 8

45 41 38

9

35

10

32

RCR 1 2 3 4

C. U. 77 69 62 56

5 6

50 45

7 8

41 37

9 10

33 30

MR4WS232120SO (Data)

0

Emergency battery pack with charger. (90 minutes at 15% of lumens for 1 lamp).

5

30°

MR

Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming T8: OC T8: SO T8: PS 4 LPB T8: O4 (not avail. in 347V) T12: LE† LPB : Number of lamps per ballast. Electrical/Wiring Options For special wiring, fusing, consult factory. Internal Fusing Consult your CFI Fluorescent representative. Radio Interference Filter 120, 277 or 347 volt, 50 or 60Hz. Suffix: R. Emergency Lighting System Suffix: O (e.g. MRWS232120SOO).

62 56

0

24" (610mm)

Special Lens - VA lens pattern 12 prismatic virgin acrylic is standard. For other available lenses, see page 155.

Features • Continuous trough appearance without interruption of ceiling cross tees. •Post painted baked white acrylic enamel reflector finish for better non-yellowing properties vs. other paints. •Hangers lock ceiling system together. •Uninterrupted wiring trough when mounted in continuous rows. • Spring-loaded lampholders. •Luminaire supports ceiling tile at end of row. •Non continuous trough available. •Optional silver reflector.

70

3 4

30°

24" (610mm)

Merchandizer 1’x 4’, 1’x 8’ (MR)

2

SQS2GFSVA332120O3 (Data)

SQS 2’ x 4’

Emergency battery pack with charger. (90 minutes at 15% of lumens for 1 lamp).

C. U. 79

1674 0°

30°

RCR 1 2 3 60° 4 5 6 7 8 9 10

C. U. 90 78 68 60 54 48 43 40 36 33

or

• T12 options are limited due to new regulations. Please consult factory for their availability. • Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forth by National Resources Canada.


Recessed Luminaires Lens and Open Reference Data

Application Data*

Efficiency Spacing Ratio

Luminaire Spacing

74.7% 1.4

Electronic Ballast Input Watts (120V) Ballast Factor

62.0W .88

FC

W/Sq Ft

8' x 8' (64 sq ft/luminaire)

55

0.8

8' x 10' (80 sq ft/luminaire)

45

0.7

62

1.2

50' x 70' x 8.5' Space

Ordering Guide Type Luminaire size Static

1x4 1x4

Lamps qty/type

Exposed T-Grid SQS1GFSVA132 SQS1GFSVA232

1-T8 2-T8

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

35

0.8

SQS2GFSVA232 Basic catalogue number : Spec Troffer Luminaire

Application Data*

Reference Data Efficiency Spacing Ratio

72.2% 1.4

Electronic Ballast Input Watts (120V) Ballast Factor

85.0W .90

Luminaire Spacing

FC

W/Sq Ft

8' x 8' (64 sq ft/luminaire)

81

1.2

8' x 10' (80 sq ft/luminaire)

66

1.0

89

1.9

50' x 70' x 8.5' Space

Ordering Guide Type Luminaire size Static

2x4 2x4 2x4

120 Voltage : 120 277 347

SO Ballast : See page 52

Lamps qty/type

Options : See page 52 add appropriate suffix to catalogue number

Exposed T-Grid SQS2GFSVA232 SQS2GFSVA332 SQS2GFSVA432

2-T8 3-T8 4-T8

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

47

1.2

SQS2GFSVA432 Basic catalogue number :

Reference Data

Application Data*

Efficiency Spacing Ratio

Luminaire Spacing

91.9% 1.4

Electronic Ballast Input Watts (120V) Ballast Factor

W/Sq Ft

84

1.2

74

1.0

50' x 70' x 12' Space 12' on centre

62.0W .88

FC

50' x 70' x 12' Space 16' on centre

96

1.3

95

1.5

Luminaire width

Luminaire Lamps length qty /type

12” 12” 12” 12” 12”

48” 48” 48” 96” 96”

MR4WS232

30' x 30' x 8.5' Space 12' on centre

Recess Static

04 Ballast :

Options :

Catalogue number 1-T8 MR4WS132 2-T8 MR4WS232 3-T8 MR4WS332 4-T8 (tandem) MR8WS232 6-T8 MR8WS332

When ordering for row mounting replace middle unit S by M. When ordering silver reflector change W by S.

50' x 70' x 8.5' Space 12' on centre

Ordering Guide Type

120 Voltage :

Basic catalogue number : MR series 2-T8 32W

120 Voltage : 120 277 347

SO Ballast : See page 52

Options : See page 52 Add appropriate suffix to catalogue number

53


Recessed Luminaires Lens

AA Troffer 1’ x 4’, 2’ x 2’ & 2’ x 4’ High Performance Lens Troffer • Static Luminaires AA248-120SOVA (Data)

AA 1’ x 4’ 0

RCR 500 60° 1000

1929

LENS RECESSED

CFI’s high performance AA series of lens troffers offers unique features that outperform and extend more value for money than any other comparable fluorescent troffer. The 2’ x 4’ and 1’ x 4’ models offer rolled over edges, integrated light leak stops, mitered corners on door frames to make this the toughest and highest performance troffer in its class. Side mount ballast on 1’ x 4’ ideal for 1 lamp applications.

60 54

5 6

49 44

7 8

40 37

9 10

34 32

0

RCR 1

24" (610 mm) 500 60°

1000

24" (610 mm) 1500 0°

C. U. 73

2 3

65 58

4 5 6 7

52 47 42 38

8 9

35 32

10

30

30°

AA348-120O3VA (Data)

AA 2’ x 4’ 3-5/8" (92 mm)

0

RCR 1 2

24" (610 mm) 1000

60°

2000

48" 1219 mm)

2758

63 56 51 46 42 38 35 32

AA448-120O4VA (Data)

AA 2’ x 4’ 0

24" (610 mm) 1000 60°

2000

End cap hold-down clip. (2' x 2', 2' x 4')

3 4 5 6 7 8 9 10

C. U. 81 71

30°

3-5/8" (92 mm)

Hemmed edge 2’ x 4’ and 1’ x 4’ for safe handling.

3 4

AA2U6-120SOVA (Data) 4" (102 mm)

• T12 options are limited due to new regulations. Please consult factory for their availability. • Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forth by National Resources Canada.

75 67

30°

AA 2’ x 2’

Features •73.3% efficient (4 lamp T8), 80.9% (3 lamp T8), 78.6% (2 lamp T8). •3-5/8" deep (2' x 4'). •All other types 4" deep. •2' x 4' luminaire side rails have rolled-over edges for maximum safety. •Flush steel full-sized door frame with mitered corner detailing. (1' x 4', 2' x 4') •Angle regressed extruded aluminum door (optional). •Built-in Hold-Down clip. (2' x 2', 2' x 4') Options pages 150-156 Drywall Kit For plaster frames, order Cat. No.: FK92X4 for (2' x 4') troffer; FK92X2 for (2' x 2') troffer; FK91X4 for (1' x 4') troffer. Internal Fusing Consult your CFI Fluorescent representative. Radio Interference Filter 120, 277 or 347 volt, 50 or 60Hz. Suffix: R. Emergency Lighting System Suffix: O (e.g. AA248-120SOVAO). Emergency battery pack with charger. (90 minutes at 15% of lumens for 1 lamp). Special Lens - VA lens pattern 12 prismatic virgin acrylic is standard. For other available lenses, see page 155.

C. U.

1 2

48" (1219 mm)

Examples of catalogue number: AA Troffer, 4 lamp, T8 Electronic, 0.095” Pattern AA448-120O4VA =

3337

12 lens, flush steel door frame

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 77 68 60 54 48 44 40 36 34 31

30°

AA series catalogue numbering system

54

48

AA

4

Family AA The Troffer

Lamp Quantity

Nominal Lamp Size

1 = 1 Lamp 2 = 2 Lamp 3 = 3 Lamp 4 = 4 Lamp

24 48 U2 U6 W8

= = = = =

120

24” 48” 6” U Lamp T12 6” U Lamp T8 2 Lamps 48” 2x4

Voltage 120 = 120V 277 = 277V 347 = 347V

SO Ballast designation LE = OC = SO = O3 =

T12 Magnetic T8 Magnetic T8 Electronic T8 Electronic (one 3-lamp) O4 = T8 Electronic (one 4-lamp)

VA Shielding designation

Door Frame

Special Options

VA = 0.095” Pattern 12 Acrylic Lens For complete shielding option listing, refer to page 155. CFI has standardized the suffix designation for all types of Troffers and Troffer options.

Blank= Flush steel RA = Regressed aluminum

For complete option listing, refer to pages 150-156.


Recessed Luminaires Lens Application Data*

Reference Data Efficiency Spacing Ratio

70.7% 1.3

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

60.0W .88

FC VCP W/Sq Ft

52

59

.9

8' x 10' (80 sq ft/luminaire) 42

59

.8

84

1.3

Ordering Guide Type AA Flush Steel Door Frame

Static

AA

48

Luminaire size

Lamps qty/type

Exposed T-Grid

1x4 1x4

1-T8/T12 2-T8/T12

AA148 AA248

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

45

2

Basic Catalogue Number AA Troffer

Application Data*

Reference Data Efficiency Spacing Ratio

69.5% 1.3

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

60.0W .88

FC VCP W/Sq Ft

48

58

0.9

8' x 10' (80 sq ft/luminaire) 40

58

0.8

81

1.2

Ordering Guide Type AA Flush Steel Door Frame

Static Static Static

120 Voltage

SO Ballast designation

VA Shielding designation

Door Frame

Special Options

Luminaire size

Lamps qty/type

Exposed T-Grid

2x2 2x2 2x2

2-T8/T12 2-T8U6 2-T12U6

AA224 AA2U6 AA2U2

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

47

AA

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

30

58

2

U6

Basic Catalogue Number

Application Data*

Reference Data Efficiency Spacing Ratio

80.9% 1.3

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing

85.0W .88

FC VCP W/Sq Ft

50' x 70' x 8.5' Space 94

61

1.3

8' x 10' (80 sq ft/luminaire) 78

61

1.1

81

1.8

8' x 8' (64 sq ft/luminaire)

120

SO

VA

0.9

Ordering Guide Type AA Flush Steel Door Frame

Static

AA

48

Voltage

Ballast designation

Shielding designation

Door Frame

Special Options

Luminaire size

Lamps qty/type

Exposed T-Grid

2x4

3-T8/T12

AA348

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

90

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

54

97

3

Basic Catalogue Number

Application Data*

Reference Data Efficiency Spacing Ratio

73.3% 1.4

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing

112.0W .88

FC VCP W/Sq Ft

50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

113 58

8' x 10' (80 sq ft/luminaire) 94

59

120

o3

VA

1.3

1.8 1.4

Ordering Guide Type AA Flush Steel Door Frame

Static Static

Voltage

Ballast designation

Shielding designation

Door Frame

Special Options

Luminaire size

Lamps qty/type

Exposed T-Grid

2x4 2x4

2-T8/T12 4-T8/T12

AA2W8†AA448

†Efficiency of 78.6% with (2) T8 lamps. 82.7% efficiency with AAS2G luminaire, see pages 56-57.

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

111 80

2.3

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

68

96

AA

2

W8

120

SO

VA

1.8 Basic Catalogue Number

*Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

Voltage

Ballast designation

Shielding designation

Door Frame

Special Options

55


Recessed Luminaires Lens

Silverescent 1’x 4’, 2’x 2’, 2’x 4’ (ELS) • High Efficiency White Paint 1’x 4’, 2’x 2’, 2’x 4’ (AAS) Energy Saving Lens Troffer • Static Luminaires ELS2GFSVA232120SO (Data)

ELS 2’ x 4’ 3-5/8" (92.1 mm)

0

24" (609.6 mm)

RCR 3-5/8" (92.1 mm)

750

24" (609.6 mm)

60°

1500

48" (1219 mm)

LENS RECESSED

Silverescent luminaires (ELS) are designed to conserve energy. The wide distribution and the 95% reflective silver laminate specular reflector in the 2 x 4, 2 lamp luminaire, provides the same lighting level as a 10 year old 2 x 4, 4 lamp luminaire with as little as 30% of the energy consumption. The high efficiency white paint (AAS) is a cost-effective way to save energy compared to specular reflector luminaires. Features •95% reflective silver laminate specular reflector protected with strippable film (ELS). •86.2% efficient (2' x 4' T8) (ELS - Silverescent). •One-piece housing is embossed for added strength. •End cap has single form configuration and formed edges for easy lamping and safety. •Turned up edges for safe handling (2' x 4'). •Lens frame overlaps end cap for positive light stop. •Reversible slim-line lens frames with 1,000 square inch lens area (2' x 4'). •Mitered appearance lens frames. •Angle regressed extruded aluminum door (RA optional). •Cam-action latches. •92% reflective white paint on AAS. •Built-in Hold-Down clip (2’ x 4’). STANDARD FS*

Flush Steel Door Frame

2390 0°

92 83

3 4

74 67

5 6

60 55

7 8

49 45

9 10

40 37

30°

ELS1GFSVA132120OC (Data)

ELS 1’ x 4’

0

RCR 200

SPECULAR SILVER REFLECTOR

60° 600

1128 0°

C. U.

1 2

86 77

3 4 5 6 7 8 9 10

69 62 56 51 46 42 38 34

30°

AAS2GFSVA232120SO (Data)

AAS 2’ x 4’

OPTION RA* Regressed Aluminum Door Frame

0

3-5/8" (92.1 mm) 500

24" (609.6 mm)

60° 1000

48" (1219 mm)

1943

*Note: Replace FS by RA in the number for regressed aluminum door frame.

SPS, SQS, AA, AAS and ELS fixtures all have these door frame options.

56

C. U.

1 2

Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming T8: OC T8: SO T8: PS 3 LPB T8: O3 (not avail. in 347V) 4 LPB T8: O4 For T12 lamp see page 151. LPB : Number of lamps per ballast. Drywall Kit For plaster frames, order Cat. No.: FK92X4 (2’ x 4’), FK91X4 (1’ x 4’), FK92X2 (2’ x 2’), Internal Fusing Consult your CFI Fluorescent representative. Radio Interference Filter 120, 277 or 347 volt, 50 or 60Hz. Suffix: R. Emergency Lighting System Suffix: O (e.g. ELS2GFSVA232120SOO). (N/A 2’ x 2’) Emergency battery pack with charger. (90 minutes at 15% of lumens for 1 lamp). Special Lens - VA lens pattern 12 prismatic virgin acrylic is standard. For other available lenses, see page 156.

30°

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 87 78 69 62 56 50 45 41 37 33


Recessed Luminaires Lens Application Data*

Reference Data Efficiency Spacing Ratio

86.2% 1.2

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

62.0W .88

FC VCP W/Sq Ft

66

69

0.9

8' x 10' (80 sq ft/luminaire) 52

69

0.8

87

1.2

Ordering Guide Type Flush Steel Door Frame

Static

Luminaire size

Lamps qty/type

2x2 2x4

2-T8U6 2-T8 3-T8 4-T8

Exposed T-Grid ELS2GFSVA26U ELS2GFSVA232 ELS2GFSVA332 ELS2GFSVA432

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

59

8' x 8' x 8.5' Cubicle/60" Partition 8' x 8' (64 sq ft/luminaire)

39

98

0.9

Basic catalogue number : 3 1/2" Deep Troffer - 95% Reflective Silver Insert

RE835 lamp rated at 3000 lumens

Application Data*

Reference Data Efficiency Spacing Ratio

80% 1.3

Electronic Ballast Input Watts (120V) Ballast Factor

31.0W .88

Luminaire Spacing

120

ELS2GFSVA232

FC VCP W/Sq Ft

50' x 70' x 8.5' Space 8’ on centre

34

59

1.0

10’ on centre

28

59

0.8

36

84

1.3

Ordering Guide Type Flush Steel Door Frame

Static

SO

Voltage : 120 277 347

Ballast : See page 56

Luminaire size

Lamps qty/type

1x4

1-T8 2-T8

Options : See page 56 Add appropriate suffix to catalogue number

Exposed T-Grid ELS1GFSVA132 ELS1GFSVA232

12' x 16' x 8.5' Space 6' on centre

120

ELS1GFSVA232

RE835 lamp rated at 2900 lumens

Basic catalogue number :

Application Data*

Reference Data Efficiency Spacing Ratio

82.7% 1.4

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing 50' x 70' x 8.5' Space

64

69

0.9

8' x 10' (80 sq ft/luminaire) 51

69

0.8

87

1.2

8' x 8' (64 sq ft/luminaire) 62.0W .88

FC VCP W/Sq Ft

Ordering Guide Type Flush Steel Door Frame

Static

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

57

RE835 lamp rated at 3000 lumens

AAS2GFSVA232 Basic catalogue number :

*Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor

Voltage :

SO Ballast :

Luminaire size

Lamps qty/type

1x4 1x4 2x2 2x4 2x4

1-T8 2-T8 2-T8U6 2-T8 3-T8

120 Voltage :

Options :

Exposed T-Grid AAS1GFSVA132 AAS1GFSVA232 AAS2GFSVA26U AAS2GFSVA232 AAS2GFSVA332

SO Ballast :

Options :

57


Recessed Luminaires Lens

Troffer (imperial or metric) 20”x 60”, 500 x 1500 Air Supply / Return or Static 20” x 60”

DSA5GLIVA232120SO (Data)

DSA 20” x 60”

5" 127 mm) 15-5/8" (397 mm)

0

RCR

500

20" (508 mm)

60° 1000

60" (1524 mm)

40" 1016 mm) 1821 0°

C. U.

1 2

77 68

3 4

61 54

5 6

49 44

7 8

40 37

9 10

34 32

30°

20” x 48”

LENS RECESSED

DTA5GLIVA232120SO (Data)

DTA 20” x 48”

5" 127 mm) 15-5/8" (397 mm)

0

RCR 1 2 3

500

20" (508 mm)

60° 1000

Features •Only 5” deep. •Faceplate made with die formed 20 gauge cold rolled steel with edges hemmed for rigidity. •Easily removable ballast cover. •Twin knockout access plate. •Luminaire efficiency 73.2%. •Lay in lens standard (see drawing LI on page 155). •Regressed and flush aluminium door frames available. Replace LI with SA, RA, FA.

48" 1219 mm)

40" 1016 mm) 1821 0°

30°

Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming T8:SO T8:PS T8:OC 3 LPB T8:O3 (not avail. in 347V) For T12 lamp see page 151. LPB : Number of lamps per ballast. Drywall Kit For plaster frames, order Cat. No.: FK9204 (20” x 48”), FK9205 (20” x 60”). Internal Fusing Consult your CFI Fluorescent representative. Radio Interference Filter 120, 277 or 347 volt, 50 or 60Hz. Suffix: R. Emergency Lighting System Suffix: O (e.g. DSA5GLIVA232120SOO). Emergency battery pack with charger. (90 minutes at 15% of lumens for 1 lamp).

Special Lens - VA lens pattern 12 prismatic virgin acrylic is standard. For other available lenses, see page 155. Static For static luminaires, replace DSA, DMA, DTA or DLA in the basic catalogue number by DSS, DMS, DTS or DLS. Filler Plate For 20” x 60” opening with 20” x 48” luminaire, order FP9205.

Double-hemmed edge along louver opening for flat surface with no light leaks.

58

C. U. 77 68 61

4 5

54 49

6 7

44 40

8 9

37 34

10

32


Recessed Luminaires Lens Application Data*

Reference Data Efficiency Spacing Ratio

73.2% 1.4

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

60.0W .88

FC VCP W/Sq Ft

Air Handling 54

64

1.3

8' x 10' (80 sq ft/luminaire) 44

64

1.0

81

1.7

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

Ordering Guide Type Luminaire size 20” x 60” 20” x 60” 500mm x 1500mm 500mm x 1500mm

Basic catalogue number : Troffer 20” x 60”

Application Data*

Efficiency Spacing Ratio

Luminaire Spacing

73.2% 1.4

Electronic Ballast Input Watts (120V) Ballast Factor

60.0W .88

FC VCP W/Sq Ft

50' x 70' x 8.5' Space 64

1.3

8' x 10' (80 sq ft/luminaire) 44

64

1.0

81

1.7

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

2-T8 3-T8 2-T8 3-T8

120

SO

Voltage : 120 277 347

Ordering Guide Type Luminaire size Air Handling

54

8' x 8' (64 sq ft/luminaire)

Catalogue number DSA5GLIVA232 DSA5GLIVA332 DMA5GLIVA232 DMA5GLIVA332

Not for continuous row mounting.

50

DSA5GLIVA232

Reference Data

Lamps qty/type

Ballast : See page 58.

Lamps qty/type

20” x 48” 20” x 48” 500mm x 1200mm 500mm x 1200mm

Options : See page 58 add appropriate suffix to catalogue number

Catalogue number DTA5GLIVA232 DTA5GLIVA332 DLA5GLIVA232 DLA5GLIVA332

2-T8 3-T8 2-T8 3-T8

Not for continuous row mounting.

50

DTA5GLIVA232 Basic catalogue number :

120 Voltage :

SO Ballast :

Options :

FACEPLATE LENS

Faceplate View Standard Lay in Lens (LI)

LI Note: Subsitute LI for:

FACEPLATE

FACEPLATE

DOOR FRAME

DOOR FRAME

FACEPLATE

LENS

LENS DOOR FRAME Faceplate View Lay in Aluminum Frame (SA)

LENS Faceplate View Flush Steel Door (FA)

Faceplate View Regressed Aluminum Door (RA)

SA

RA

FA

Standard Lift & Shift Aluminum Frame. Replace LI by SA.

Regressed Aluminum Lift & Shift Frame. Replace LI by RA.

Flush Aluminum Lift & Shift Frame. Replace LI by FA.

*Average Footcandles Maintained Total LLF=BF (.90) x .85 = .74 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

59


Recessed Wallwasher Luminaires

Wal-Lyter 2’, 4’ Wall Washer / Accent Light • High Performance / Specular Optic Wal-Lyter 24”

WLRN124120BX (Data)

10-13/16" (275 mm) 4-7/16" (113 mm) 7-13-16" (183 mm) Opening Opening

0

500

10-13/16" (275 mm) Optional Lens

60°

4-7/16" (113 mm)

7-13-16" (183 mm) Opening Opening

WALL WASHING

Wal-Lyter is a high performance wall-washer that delivers the highest light levels and an exceptionally even wash of light from the ceiling line to the floor line utilizing TT5 compact fluorescent lamps. It is much more efficient and more cost effective than most incandescent units producing equivalent illumination. Wal-Lyter is ideal for highlighting merchandise displays, brightening the walls in offices illuminated with sharp cut-off parabolics and for many other wall lighting applications. Lamp is never in view for normal wall wash applications. Features •Low iridescent specular reflector system for precise controlled light output. •Evenly lights vertical surfaces or displays. •87% energy savings vs. incandescent. •3150 lumen (40 watt) TT5 type lamp requires fewer luminaires to provide the same wall illumination as a 60 watt incandescent wallwasher. •20,000 hours TT5 lamp life requires less maintenance than incandescent wallwasher. •Fits all lay-in grid ceiling systems. •One-piece body and integral hanger for easy, quick installation. •WLRK lens, extruded acrylic prismatic lens to hide lamp from direct view when looking into the luminaire. Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add uffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming 40W TT5: BX 40W TT5: SB 40W TT5: PB 50W TT5: BE 50W, 55W TT5: PC 55W TT5: BF (not avail. in 347V) T8 and T12 not available*. Drywall Kit For plaster frames, order Cat. No.: WL2DF (2’ luminaires), WL4DF (4’ luminaires). Internal Fusing Consult your CFI Fluorescent representative. Radio Interference Filter 120, 277 or 347 volt, 50 or 60Hz. Suffix: R. Lamp Shield K19 acrylic prismatic lens shield on WLRK luminaire. * For T8 see Wallmaster on page 151.

60

1000

1500

30°

24" (610 mm)

Wal-Lyter 48”

WLRN244120BX (Data)

10-13/16" (275 mm) 4-7/16" (113 mm) 7-13-16" (183 mm) Opening Opening

0

1000

10-13/16" (275 mm) Optional Lens

60°

4-7/16" (113 mm)

2000

7-13-16" (183 mm) Opening Opening 3000

30°

48" (1219 mm)

Integral Hanger Luminaire installs easily with adjustable integral hanger that clamps to T bar. Wire luminaire through access plate without opening lamp compartment.

Drywall Frame Catalogue No., WL2DF (2'), WL4DF (4').


Recessed Luminaires Wallwash Footcandles on Wall Luminaires: 3 feet from wall to outside trim on lamp side of luminaire (without lens)* WLRN124BX Individual Wal-Lyter 0' 1' 2' 3' 4' 5' 6' 7' 8' Ceiling 8' 7' 6' 5' 4' 3' 2' 1' Floor

76 64 47 33 26 19 15 13

67 60 44 34 28 21 16 12

46 46 36 29 23 20 15 11

25 29 24 24 20 17 13 11

14 17 17 14 14 12 11 10

8 10 12 10 11 9 9 8

5 7 8 8 8 8 8 7

4 5 6 6 6 6 6 6

Ordering Guide Lamp Lamp qty/type watts

Multiple Units 6'

4'

3 4 4 5 5 5 5 5

107 102 85 66 59 48 42 38

104 104 86 74 65 53 44 37

102 106 88 74 62 56 46 36

104 104 86 74 65 53 44 37

86 78 63 49 42 35 31 28

107 102 85 66 59 48 42 38

79 75 62 50 45 36 31 26

63 67 57 48 42 37 31 26

50 58 48 48 40 34 26 22

63 67 57 48 42 37 31 26

79 75 62 50 45 36 31 26

1-TT5 1-TT5 1-TT5

86 78 63 49 42 35 31 27

Ceiling 8' 7' 6' 5' 4' 3' 2' 1' Floor

0'

1'

2'

111 113 86 63 51 40 31 24

101 104 81 59 49 39 30 24

76 82 67 51 43 35 28 23

48 56 50 42 36 30 25 21

28 36 35 32 29 25 22 19

18 24 25 24 23 21 19 17

13 17 18 18 18 17 16 15

10 13 13 14 14 14 13 13

9 10 10 11 11 11 11 11

6' 124 130 104 81 69 57 47 39

119 127 106 84 71 59 49 40

104 117 102 83 72 60 50 41

95 111 100 83 71 60 50 42

104 117 102 83 72 60 50 41

Multiple Units 8' Ceiling 8' 7' 6' 5' 4' 3' 2' 1' Floor

120 124 98 74 62 52 43 36

111 117 95 74 63 53 44 37

89 98 85 70 61 52 44 37

66 79 74 66 58 51 43 37

57 71 70 64 57 50 43 37

66 79 74 66 58 51 43 37

89 98 85 70 61 52 44 37

111 117 95 74 63 53 44 37

Ordering Guide Lamp Lamp qty/type watts

Multiple Units 8'

120 124 98 74 63 52 43 36

0'

1'

2'

3'

4'

5'

181 200 173 143 125 108 92 79

182 201 175 146 128 110 94 80

183 203 176 147 129 111 95 81

183 203 177 148 130 112 96 82

184 203 177 148 130 113 96 83

183 203 177 148 130 112 96 82

40W 50W 55W

Number with lens WLRK124 WLRK125 WLRK126

Nominal Length 24"

Footcandles on Wall Luminaires: 3 feet from wall to outside trim on lamp side of luminaire (without lens)* WLRN244BX Individual Wal-Lyter 3' 4' 5' 6' 7'

Catalogue no lens WLRN124 WLRN125 WLRN126

119 127 106 83 71 59 49 40

124 130 104 81 69 57 47 39

2-TT5 2-TT5 2-TT5

Catalogue no lens WLRN244 WLRN245 WLRN246

40W 50W 55W

Number with lens WLRK244 WLRK245 WLRK246

Nominal Length 48"

Continuous Row 6' 7' 8' 183 203 176 147 129 111 95 81

182 201 175 146 128 110 94 80

181 200 173 143 125 108 92 77

*Recommended position

WLRN124 Basic catalogue number : Wal-Lyter

W W A AL L L

120 Voltage : 120 277 347

SB Ballast : See page 60

Options : See page 60 Add appropriate suffix to catalogue

3'

L

61


Recessed Wallwasher Luminaires

Walmaster 2’, 4’ Wall Washer / Accent Light • Semi-Specular Optic WMRL124120BX (Data)

Walmaster 24” TT5 lamp

0

9-7/8" (251 mm) 4-7/16" (113 mm) 600

7-7/8" (178 mm)

60°

1200

WALL WASHING

Walmaster is a cost-effective high performance luminaire that delivers good light levels and an even wash of light. Low-iridescence semi-specular reflectors do not protrude below the ceiling line. This provides a clean appearance while controlling the light output of a T8 or TT5 lamp to illuminate vertical surfaces uniformly. Features •Low iridescent semi-specular reflector system for precise controlled light output. •Evenly lights vertical surfaces or displays (no scallops). •87% energy savings vs. incandescent. •Less than 3:1 maximum to minimum wall illumination when installed 6 feet on centre. •20,000 hours lamp life requires less maintenance than incandescent. •No edges protrude below ceiling line. •Can be installed only 2 feet from wall to farthest edge of luminaire (3' maximum). •Fits all standard and narrow grid ceiling systems. •One-piece body and integral hanger for easy, quick installation. •Sides of luminaire can support tile or sit on T-bar. Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming 40W TT5: BX 40W TT5: SB 40W TT5: PB T8: OC 50W TT5: BE 50W, 55W TT5: PC 55W TT5: BF T8:PS T8: SO (not avail. in 347V) T12 not available. Drywall Kit For plaster frames, order Cat. No.: WL2DF (2’ luminaire), WL4DF (4’ luminaire). Internal Fusing Consult your CFI Fluorescent representative. Radio Interference Filter 120, 277 or 347 volt, 50 or 60Hz. Suffix: R.

1800

24" (610 mm)

30°

WMRL244120BX (Data)

Walmaster 48” TT5 lamp 0

9-7/8" (251 mm) 4-7/16" (113 mm) 7-7/8" (178 mm)

1000 60° 2000

3000

48" (1219 mm)

30°

WMRL143120OC (Data)

Walmaster 48” T8 lamp 0

9-7/8" (251 mm) 4-7/16" (113 mm)

500

7-7/8" (178 mm)

60°

1000

48" (1219 mm)

1500 0°

Integral Hanger Luminaire installs easily with hanger clips. Wire luminaire thru access plate without opening lamp compartment.

62

Drywall Frame Catalogue No. WL2DF (2') WL4DF (4').

30°


Recessed Luminaires Wallwash Footcandles on Wall Luminaires: 3 feet from wall to outside trim on lamp side of luminaire* WMRL124120BX INDIVIDUAL WALMASTER 0’ 1’ 2’ 3’ 4’ 5’ 6’ 7’ Ceiling 8' 7' 6' 5' 4' 3' 2' 1' Floor

52 56 43 32 24 19 15 12

41 48 39 30 23 18 14 12

24 32 29 24 20 16 13 11

13 19 19 18 15 13 11 10

8 12 13 13 12 11 9 8

6 8 9 9 9 9 8 7

5 6 7 7 7 7 7 7

4 5 5 6 6 6 6 6

MULTIPLE UNITS 4' 71 83 72 60 50 41 34 28

64 79 70 60 50 41 34 28

56 74 69 60 50 41 34 28

64 79 70 60 50 41 34 28

71 83 72 60 50 41 34 28

61 66 54 44 35 28 24 20

CONTINUOUS ROW 0' 1' 2' 3' 4' 5' 6' 7' 8'

6' 51 60 51 42 34 28 24 20

35 47 45 40 34 28 24 20

29 41 41 38 33 28 24 20

35 47 45 40 34 28 24 20

51 60 51 42 34 28 24 20

61 66 54 44 35 28 24 20

119 144 125 105 86 71 58 47

122 149 131 109 91 74 61 50

123 152 134 113 94 77 63 51

124 153 136 114 95 78 64 52

124 153 136 115 96 78 65 52

124 153 136 114 95 78 64 52

123 152 134 113 94 77 63 51

122 149 131 109 91 74 61 50

119 144 125 105 86 71 58 47

Footcandles on Wall Luminaires: 3 feet from wall to outside trim on lamp side of luminaire* WMRL244120BX 0' Ceiling 8' 7' 6' 5' 4' 3' 2' 1' Floor

116 119 92 69 52 40 32 26

INDIVIDUAL WALMASTER 1' 2' 3' 4' 5' 6' 88 102 83 64 50 39 31 25

51 71 64 53 43 35 29 23

30 45 45 40 35 30 25 21

19 29 31 30 27 24 21 18

13 19 22 22 21 19 17 15

10 14 16 16 17 16 15 13

8 11 12 13 13 13 12 12

135 142 117 95 79 66 56 47

MULTIPLE UNITS 8' Ceiling 8' 7' 6' 5' 4' 3' 2' 1' Floor

124 128 102 80 64 52 43 36

97 113 95 77 63 52 44 36

61 85 80 69 60 51 43 36

43 65 67 62 56 49 42 36

37 58 62 59 54 47 42 36

43 65 67 62 56 49 42 36

61 85 80 70 60 51 43 36

97 113 96 77 63 52 44 36

124 128 102 80 64 52 43 36

109 130 114 95 80 67 57 49

0'

1'

2'

151 166 142 119 100 85 73 63

134 167 149 126 106 90 77 66

119 164 152 131 112 94 80 68

77 108 104 92 79 67 58 50

67 88 99 90 79 69 59 51

77 109 105 94 81 70 60 51

CONTINUOUS ROW 3' 4' 5' 139 176 159 136 115 97 83 70

162 186 164 139 117 99 85 72

140 178 162 139 118 100 86 72

110 133 117 99 84 71 61 52

137 147 123 102 86 72 61 52

Ceiling 8' 7' 6' 5' 4' 3' 2' 1' Floor

0'

7'

49 49 36 27 21 16 13 11

38 42 33 25 20 16 13 10

3 4 5 5 5 5 5 5

21 29 25 21 17 14 12 10

12 18 18 16 14 12 10 9

8 12 12 12 11 9 9 8

5 8 8 9 8 8 7 6

4 6 6 7 7 6 6 6

6'

7'

8'

122 170 159 139 119 101 86 73

140 178 162 139 118 100 86 72

162 186 164 139 117 99 85 72

MULTIPLE UNITS 8' Ceiling 8' 7' 6' 5' 4' 3' 2' 1' Floor

53 52 41 32 25 21 18 15

41 46 38 30 25 21 18 15

26 34 32 27 24 20 18 15

18 26 26 25 22 20 17 15

16 23 24 24 21 19 17 15

18 26 26 25 22 20 17 15

26 34 32 27 24 20 18 15

41 46 38 30 25 21 18 15

53 52 41 32 25 21 18 15

46 54 45 38 32 28 24 21

0'

1'

2'

50 67 60 52 46 38 33 28

59 71 63 54 46 39 34 29

68 76 65 55 47 40 35 30

32 44 41 37 32 28 24 21

28 40 39 36 31 28 24 21

32 44 41 37 32 28 24 21

CONTINUOUS ROW 3' 4' 5' 59 72 64 55 47 40 35 30

51 69 63 55 48 41 35 30

59 72 64 55 47 40 35 30

46 54 45 38 32 28 24 21

40W 50W 55W

Catalogue number WMRL244 WMRL245 WMRL246

Nominal length 48”

Ordering Guide Lamp Lamp qty/type watts

MULTIPLE UNITS 6' 58 59 48 39 33 28 25 21

40W 50W 55W

Catalogue number WMRL124 WMRL125 WMRL126

Nominal length 24”

2-TT5 2-TT5 2-TT5

Footcandles on Wall Luminaires: 3 feet from wall to outside trim on lamp side of luminaire* WMRL143120SO INDIVIDUAL WALMASTER 1' 2' 3' 4' 5' 6'

1-TT5 1-TT5 1-TT5

Ordering Guide Lamp Lamp qty/type watts

MULTIPLE UNITS 6'

7'

Ordering Guide Lamp Lamp qty/type watts

58 59 48 39 33 28 25 21

1-T8

32W

Catalogue number WMRL143

Nominal length 48”

6'

7'

8'

68 76 65 55 46 40 35 30

59 71 63 54 46 39 34 29

50 67 60 52 46 38 33 28

*Recommended position

WMRL124 Basic catalogue number : Walmaster

W W A A LL LL

120 Voltage : 120 277 347

SB Ballast : See page 62

Options : See page 62 Add appropriate suffix to catalogue

3'

63


Surface Wallwasher Luminaires

Bi-Lyter 2’, 4’ Wall Washer Ceiling Mount or Indirect Wall Mount Wall Washer

BLSW124120SB (Data)

Wall Washer TT5

0

C E I L I N G 500

4" (102 mm)

60°

1000

4-3/8" (111 mm) 0°

30°

Indirect Wall Mount

WALL WASHING

BLSW124120SB (Data)

Indirect Wall Mount TT5 180°

150°

W A

4-3/8" (111 mm)

708

L Features •Same luminaire can be used as a wall washer when ceiling mounted, or for indirect lighting when wall mounted. •Only 4” deep. •Meets ADA when wall mounted. •Soft rounded corners and edges create an elegant appearance. •20 gauge cold rolled steel body. •Specular reflector. •No visible hardware. •4’ unit: 2-TT5 or 1-T8 lamps. •2’ unit: 1-TT5 lamp. •Matte white baked acrylic finish. •Can be used in continuous rows. Consult factory. •Can be stem mounted. Options pages 150-156 Ballast Specify voltage (120 or 277) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming — 40W TT5: SB 40W TT5: PB 50W TT5: BE 50W, 55W TT5: PC 55W TT5: BF T8: PS T8: SO (not avail. in 347V) T12 not available.

L

500

4" (102 mm)

120°

250

90°

0

Indirect Wall Mount T8

Wall Washer T8

C E I L I N G

W A

4" (102 mm)

L L 4-3/8" (111 mm)

2' Unit

Internal Fusing Internal fast-blow fusing. SUFFIX: GLR Internal slow-blow fusing. SUFFIX: GMF. Electrical/Wiring Options Consult factory. For Linear T5 Consult factory.

4-3/8" (111 mm)

9/32" Mounting Hole 7/8" Dia. K.O.

4" (102 mm)

15/16" (24mm)

1/2" (13mm) 4-3/8" (111 mm) 18-3/8" (467 mm)

Note: Fixture N/A for 347V. For continuous row mounting, order part number BLSWCOUPLER for each joint.

24-3/8" (619 mm) 25-7/8" (657 mm)

4' Unit 9/32" 1/2" (13mm)

7/8"

15/16" (24mm)

Mounting Hole Dia. K.O.

21-11/16" (551mm) 4-3/8" (111 mm) 43-3/8" (1102 mm) 48-11/16" (1237 mm)

64

50-3/16" (1275 mm)


Surface / Wall Luminaires Wall Washer Footcandles on Wall Luminaires: 3 feet from wall to outside trim on lamp side of luminaire. BLSW124120SB Maintained footcandle readings on wall with 40-watt lamp. Individual Bi-Lyter 0' 1' 2' 3' 4' 5' 6' 7' 8' Ceiling 8' 7' 6' 5' 4' 3' 2' 1' Floor

4 4 4 4 3 3 3 2

5 5 5 5 4 3 3 3

6 6 6 6 5 4 3 3

9 9 9 7 6 5 4 3

14 14 13 10 8 6 4 3

25 24 20 16 10 7 5 4

46 40 31 22 13 8 5 4

72 60 42 27 15 9 6 4

Multiple Units 6'

4'

86 70 47 30 17 9 6 4

100 83 59 40 24 15 10 8

98 84 63 43 26 16 10 8

92 81 63 43 26 16 11 8

93 76 53 35 21 13 9 7

98 100 84 83 63 59 43 40 26 24 16 15 10 10 8 8

82 69 51 35 21 14 9 7

Small Office Application

60 54 44 32 21 14 9 7

50 47 41 31 21 14 9 7

0' 1' 60 54 44 32 21 14 9 7

82 69 51 35 21 14 9 7

93 76 53 35 21 13 9 7

157 134 101 71 45 30 21 17

184 158 118 82 51 33 23 17

Continuous Row 2' 3' 4' 5' 6' 7' 8' 199 204 170 176 128 134 89 93 55 57 35 36 24 25 18 18

207 178 135 94 58 36 25 19

204 176 134 93 57 36 25 18

199 170 128 89 55 35 24 18

184 158 118 82 51 33 23 17

157 134 101 71 45 30 21 17

North wall 51

50

50 50

51

53

53

52 53

53

Luminaire mounted 18" from ceiling 12' x 12' Office Space / 9' Ceiling Height

54

54

53 54

54

Reflectance: 80% Ceiling, 80% Wall, 50% Floor.

53

53

52 53

53

50

50 50

51

51

East Wall

West wall

Only four By-Lyters 55 watt lamp are required to illuminate a 12' x 12' (80/80/50) office space to 50 maintained footcandles with only 1.68 watts per square foot.

Reported numbers are maintained footcandles at desk top level with 55 watt lamp. Footcandle readings will vary depending on room reflectance.

1.68 watts per square foot

DK Door

South wall

Corridor Application Corridor maintained footcandle readings at floor level with 40 watt lamp (BLSW124120SB). Luminaire mounted 18" from ceiling.

17

17

18

19

19

19

19

19

19

19

19

19

19

18

18

17

18

18

19

19

20

19

19

19

19

19

19

19

19

18

17

18

19

19

19

20

19

19

19

19

19

19

19

19

18

18

18

19

19

19

20

20

20

20

20

19

19

19

18

18

18

19

19

19

19

19

19

20

20

20

19

19

19

18

18

18

19

19

19

19

19

19

19

19

20

19

19

18

18

17

17

18

19

19

19

19

19

19

19

19

19

19

18

17

17

Ordering Guide Luminaire length

Lamp qty/type

Lamp watts

24" 24" 24"

1-TT5 1-TT5 1-TT5

40W 50W 55W

48" 48" 48"

2-TT5 2-TT5 2-TT5

40W 50W 55W

48"

1-T8

32W

BLSW126

120

Basic catalogue number :Voltage : Bi-Lyter 120 Surface Wall or 277 Ceiling Mounted

T-Grid Mounting Order Catalog Number : BLSMOUNT

Continuous Row Coupler Order Catalog Number : BLSWCOUPLER

Catalogue number BLSW124 BLSW125 BLSW126 BLSW244 BLSW245 BLSW246 BLSW143

BF Ballast : Option : See page 64 See page 64 Add appropriate suffix to catalogue number

Wall Mount Spacer For uneven walls or a floating visual effect. Order Catalog Number : BLSWSPACER

65


Surface Luminaires

Slimlyte T5 (TSL) Under Shelf Task Luminaires Slimlyte TSL

A

1 1/32"

Features

SURFACE

Slimlyte • 11/32" shallow depth. • Use high efficiency compact linear T5 lamp. • Three nominal lengths: 22-19/32”, 34-7/16”, 46-7/32”. • Grounded convenience outlet, optional. • On/off rocker switch included. • Baked white enamel finish. Options Internal Fusing Add Sufix: F.

Taskmaster II (TCU)

2 7/16"

WATTAGE 14W 21W 28W

A

22 19/32" 34 7/16" 46 7/32"

Taskmaster II TCU

A

1 1/32"

Features Taskmaster II • 1 7/8" shallow depth • Four nominal lengths: 18", 24", 36", 48" • Grounded convenience outlet (optional). • On/off switch, optional. • Baked white enamel finish. Options Rocker Switch Add Suffix: H (120V only). Grounded Convenience Outlet Add Suffix: CO. Internal Fusing Add Sufix: F.

66

2 7/16"

15W 18 1/8" 17W or 20W 24 1/8" 25W or 30W 36 1/8" 32W or 34W 48 1/8"


Surface Luminaires

Ordering Guide Type Slimlyte

TSL4128 Basic catalogue number: Slimlyte T5 Surface luminaire

Ordering Guide Type Taskmaster II

Luminaire size

Lamps* qty/type

Catalogue number

22-19/32" 34-7/16" 46-7/32"

1-14W T5 1-21W T5 1-28W T5

TSL2114 TSL3121 TSL4128

120

PI

Voltage :

Ballast :

Options :

120 277

See page 66

See page 66 Add appropriate suffix to catalogue number

Luminaire size

Lamps* qty/type

Catalogue number

18-1/8" 24-1/8" 36-1/8" 48-1/8" 24-1/8" 36-1/8" 48-1/8"

1-15TS 1-20TS 1-25RS 1-34RS 1-17W T8 1-25W T8 1-32W T8

TCU15W120 TCU20W120 TCU25W TCU34W TCU17W TCU25W TCU32W

* TS = Trigger Start T12 RS = T12

TCU32W Basic catalogue number: Taskmaster Surface luminaire

120

SO

Voltage :

Ballast :

Options :

120 277 347

See page 66

See page 66 Add appropriate suffix to catalogue number

67


Pendant and Surface Luminaires

Vision Smart Surface 1’x 4’ (VRB) 3’’ Deep Cells Parabolic Louver VRB1S8LS132120SO

VRB 1’ x 4’

5-1/2" (140mm)

•• • • • •••

60°

12"(305mm) 0°

30°

Features

SURFACE

• 20 gauge steel welded body. • Side mounted ballast for cooler operation. • 45° mitered corners (body and louver). • 3" deep cell aluminum parabolic louver. • Spring-loaded latches. • Perfectly uniform four side reveal. • Low-iridescence, semi-specular aluminum, standard. • Louver has polyethylene dust guard. • Louver assembly can be replaced with any of 3 standard Lightolier door frames. Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming T8: OC T8: SO T8: PS For T12 options see page 151. LPB : Number of lamps per ballast. Internal Fusing Consult your CFI Fluorescent representative. Electrical/Wiring Options For special wiring or emergency pack, consult factory. Stem and Canopy Sets Suspend luminaire 12", 18", 24", 36" or 48" from surface. (Four per luminaire is recommended.) catalogue Number: STKF12 (12"); STKF18 (18"); STKF24 (24"); STKF36 (36"); STKF48 (48").

68

8 8cells cells Cells 12 12 Cells VRB1S24LS232120SO

VRB 1’ x 4’

5-1/2" (140mm) 60°

12"(305mm) 0°

24 cells 24 Cells

30°


Pendant and Surface Luminaires

Reference Data Efficiency Spacing Ratio

Application Data* 66.0% 1.9

Electronic Ballast Input Watts (120V) Ballast Factor

32.0W 0.88

Luminaire Spacing FC VCP W/Sq Ft 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/fixture)

29 95

0.5

8' x 10' (80 sq ft/fixture)

24 95

0.4

28 86

0.6

Ordering Guide Type Luminaire size Surface Parabolic

1x4 1x4 1x4 1x4

Cells

Lamps qty/type

8 12 8 12

Catalogue number VRB1S8LS132 VRB1S12LS132 VRB1S8LS232 VRB1S12LS232

1-T8 1-T8 2-T8 2-T8

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/fixture)

8' x 8' x 8.5' Cubicle/60"Partition 8' x 8' (64 sq ft/fixture)

15 98

0.5

VRB1S8LS132 Basic catalogue number : Premium Lensed Surface Luminaire

Application Data*

Reference Data Efficiency Spacing Ratio

48.6% 1.2

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing FC VCP W/Sq Ft 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/fixture)

62.0W 0.88

42 95

0.9

43 85

1.2

Ordering Guide Type Luminaire size Surface Parabolic

1x4

SO

120 Voltage : 120 277 347

Cells

Ballast : See page 68

Lamps qty/type

24

Options : See page 68 Add appropriate suffix to catalogue number

Catalogue number VRB1S24LS232

2-T8

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/fixture)

8' x 8' x 8.5' Cubicle/60"Partition 8' x 8' (64 sq ft/fixture)

24 95

0.9

VRB1S24LS232 Basic catalogue number : Premium Lensed Surface Luminaire

* Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

120 Voltage : 120 277 347

SO Ballast : See page 68

Options : See page 68 Add appropriate suffix to catalogue number

69


Pendant and Surface Luminaires

Deepcel Surface 2’x 2’, 2’x 4’ (DPB) 3’’ Deep Cells Parabolic Louver DPB 2’ x 4’

DPB2S18LS332120O3 (Data) 5-1/2" (140 mm)

0

24" (610 mm) 500

5-1/2" (140 mm)

RCR 1 60°

1000

24" (610 mm) 5-1/2" (140 mm) 24" (610 mm)

SURFACE

Features • Only 5-1/2" deep. • Welded 20 gauge steel body. • 45° mitered corners (body and louver). • Side-mounted ballast for cooler operation. • 3" deep aluminum parabolic louver. • Vertical grain on louver eliminates reflected lamp image on cross baffle. • Matches Deepcel 1 x 4, 2 x 2 and 2 x 4 recessed. • Perfectly uniform four-side black reveal. • Spring-loaded latches. • Reversible louver hinging. • Door jamb with integral positive light stop. • Flush end K.O.’s for smooth surface appearance (at end of row or individual). • Louver has polyethylene dust guard. Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming 40W TT5: BX 40W TT5: SB 40W TT5: PB T8: OC 50W TT5: BE T8: PS 55W TT5: BF (not avail. in 347V) 3 LPB 40W TT5: X3 T8: SO 3 LPB T8: O3 4 LPB T8: O4 For T12 lamp see page 151. LPB : Number of lamps per ballast. Internal Fusing Consult your CFI Fluorescent representative. Electrical/Wiring Options For special wiring or emergency pack, consult factory. Stem and Canopy Sets Suspend luminaire 12", 18", 24", 36" or 48" from surface. (Four per luminaire is recommended.) catalogue number: STKF12 (12"); STKF18 (18"); STKF24 (24"); STKF36 (36"); STKF48 (48"). (White finish) Louver Finish Low iridescence semi-specular is standard. Consult factory for other finishes.

70

2346

48" (1219 mm)

30°

C. U. 75

2 3

68 61

4 5

55 49

6 7

44 39

8 9

35 31

10

28

18 Cells Cells 24 24 Cells Cells 32 Cells 12 Cells 18

DPB2S9LS26U120SO (Data)

DPB 2’ x 2’

5-1/2" (140 mm)

0

5-1/2" (140 mm)

500

24" (610 mm)

60°

24" (610 mm) 5-1/2" (140 mm)

1000

24" (610 mm) 24" (610 mm) 99Cells Cells

12 12 Cells Cells

16 16Cells Cells

9 10

1415 0°

RCR 1 2 3 4 5 6 7 8

30°

C. U. 62 56 51 46 41 37 33 29 26 24


Pendant and Surface Luminaires

Reference Data Efficiency Spacing Ratio

Application Data* 69.6% 1.6

Electronic Ballast Input Watts (120V) Ballast Factor

85.0W .88

Luminaire Spacing FC VCP W/Sq Ft 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire) 91 91

1.3

8' x 10' (80 sq ft/luminaire) 75 92

1.1

Ordering Guide Type Luminaire size Surface Parabolic

2x4 2x4 2x4 2x4

Cells

Lamps qty/type

12 18 24 32

Catalogue number DPB2S12LS232 DPB2S18LS332 DPB2S24LS332 DPB2S32LS432

2-T8 3-T8 3-T8 4-T8

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire) 89 78

1.8

8' x 8' x 8.5' Cubicle/60"Partition 8' x 8' (64 sq ft/luminaire) 52 97

1.3

DPB2S18LS332 Basic catalogue number : Deepcell Surface

Application Data*

Reference Data Efficiency Spacing Ratio

57.6% 1.4

Electronic Ballast Input Watts (120V) Ballast Factor

60.0W .88

Luminaire Spacing FC VCP W/Sq Ft 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire) 50 93

0.9

8' x 10' (80 sq ft/luminaire) 41 94

0.8

Ordering Guide Type Luminaire size Surface Parabolic

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire) 50 79

1.2

2x2 2x2 2x2 2x2 2x2 2x2 2X2

03

120 Voltage : 120 277 347

Cells

Ballast : See page 70

Lamps qty/type

9 12 16 9 9 12 12

Options : See page 70 Add appropriate suffix to catalogue number

Catalogue number DPB2S9LS26U DPB2S12LS26U DPB2S16LS26U DPB2S9LS3FT DPB2S9LS32U DPB2S12LS3FT DPB2S12LS32U

2-T8U6 2-T8U6 2-T8U6 3-TT5 3-T8U1.6 3-TT5 3-T8U1.6

8' x 8' x 8.5' Cubicle/60"Partition 8' x 8' (64 sq ft/luminaire) 30 93

0.9

DPB2S9LS26U Basic catalogue number :

* Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

120 Voltage :

SO Ballast :

Options :

71


Surface Luminaires

Vision Smart Surface 8”x 48”, 1’x 4’ (ADB) High Performance Parabolic Louver

ADB

ADB8S16MS132120SO (Data)

ADB 8” x 48”

5-1/2" (140mm)

0

RCR

500

7-1/4" (184mm)

60°

1000

48" (1219mm)

SURFACE

Features •20 gauge steel welded body. •Side mounted ballast for cooler operation. •45° mitered corners (body and louver). •Perfectly uniform four side reveal. •Louver has polyethylene dust guard. ADB •Meets IES RP-1 Preferred luminance criteria. •Louver securely held with concealed Torsiontite springs. •Matte low iridescence, pre-anodized aluminum louver-reflector. •1 x 4 less than 5” deep (4-11/16”). MLB •3-1/2" x 3-1/2" cell aluminum parabolic louver. 1-1/2" deep. •Spring-loaded latches. •Low-iridescence, semi-specular aluminum, standard. • Vertical grain on louver eliminates reflected lamp image on cross baffle. •Louver assembly can be replaced with a regresses aluminium door (see page 155).

Parabaffle Surface 2’x 2’, 2’x 4’ (MLB)

16 Cells 1462 0°

C. U.

1 2

67 63

3 4

58 54

5 6

50 46

7 8

43 39

9 10

36 33

30°

ADB1S32MS232120SO (Data)

ADB 1’ x 4’

0

4-11/16" (119mm) 12" (305mm)

RCR

1000

68 63 58 53 49 45

7 8

42 39

9 10

36 34

2000

48" (1219mm)

32 Cells 2340 0°

MLB 2’ x 2’

C. U.

1 2 60° 3 4 5 6

30°

MLB2S36LS26U120SO (Data)

0

5-1/2" (140 mm) 500

24" (610 mm)

60°

4 5 6 7 8 9 10

5-1/2" (140 mm) 1000

24" (610 mm) 24" (610 mm)

Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming 40W TT5: BX 40W TT5: SB 40W TT5: PB T8: OC 50W TT5: BE T8: PS 55W TT5: BF (not avail. in 347V) 3 LPB 40W TT5: X3 T8: SO 3 LPB T8: O3 4 LPB T8: O4 For T12 options see page 151. (T12 not available for ADB) LPB : Number of lamps per ballast. Internal Fusing Consult your CFI Fluorescent representative. Electrical/Wiring Options For special wiring or emergency pack, consult factory. Stem and Canopy Sets Suspend luminaire 12", 18", 24", 36" or 48" from surface. (Four per luminaire is recommended.) catalogue Number: STKF12 (12"); STKF18 (18"); STKF24 (24"); STKF36 (36"); STKF48 (48").

36 Cells

C. U. 62 57 51 46 41 37 33 30 27 24

30°

MLB2S78LS332120O3 (Data)

MLB 2’ x 4’

5-1/2" (140 mm)

0

24" (610 mm) 5-1/2" (140 mm)

900 60°

24" (610 mm) 5-1/2" (140 mm)

1800

24" (610 mm) 2700

48" (1219 mm)

72

1500 0°

RCR 1 2 3

78 78Cells Cells

30°

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 67 60 54 49 44 39 35 31 28 25


Pendant and Surface Luminaires

Reference Data

Application Data*

Efficiency Spacing Ratio

Luminaire Spacing

62.4% 1.0

FC VCP W/Sq Ft

50' x 70' x 8.5' Space

LUMINOUS INTENSITY

8' x 6' (48 sq ft/luminaire)

33

99

0.6

55 65° 75° 85°

8' x 8' (64 sq ft/luminaire)

25

99

0.5

26

99

0.6

5cd 0cd 0cd 0cd

31.0W .88

6' x 8' (48 sq ft/luminaire)

8' x 6' (48 sq ft/luminaire)

21

99

0.6

62.0% 1.2

Luminaire Spacing

1-T8

FC VCP W/Sq Ft

Type Surface

99

1.0

55 65° 75° 85°

8' x 10' (80 sq ft/luminaire) 39

99

0.8

99

1.3

4cd 0cd 0cd 0cd

120

ADB8S16MS132

50' x 70' x 8.5' Space 46

SO

Voltage : 120 277 347

Ballast : See page 72

Options : See page 72 Add appropriate suffix to catalogue number

Luminaire size

Cells

1’ x 4’

32

Lamps qty/type

Catalogue number ADB1S32MS232

2-T8

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

46

8' x 8' x 8.5' Cubicle/60"Partition

Electronic Ballast 62.0W .88

8' x 8' (64 sq ft/luminaire)

31

99

1.0

57.8% 1.5

Electronic Ballast

Luminaire Spacing FC VCP W/Sq Ft 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

60W .88

44

84

0.9

8' x 10' (80 sq ft/luminaire) 36

84

0.8

79

1.2

120

SO

Voltage :

Ballast :

ADB1S32MS232 Basic catalogue number :

Application Data*

Reference Data

Input Watts (120V) Ballast Factor

Catalogue number ADB8S16MS132

Ordering Guide

8' x 8' (64 sq ft/luminaire)

Efficiency Spacing Ratio

16

Basic catalogue number : Vision Smart Surface

LUMINOUS INTENSITY

Input Watts (120V) Ballast Factor

8” x 48”

Lamps qty/type

12' x 16' x 8.5' Space

Application Data*

Reference Data Efficiency Spacing Ratio

Surface Parabolic

Cells

8' x 8' x 8.5' Cubicle/60"Partition

Electronic Ballast Input Watts (120V) Ballast Factor

Ordering Guide Type Luminaire size

Ordering Guide Type Luminaire size Surface Parabolic

2’ x 2’

Cells

Lamps qty/type

36 36 36

Options :

Catalogue number MLB2S36LS26U MLB2S36LS32U MLB2S36LS3FT

2-T8U6 3-T8U1.6 3- TT5

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

43

8' x 8' x 8.5' Cubicle/60"Partition 8' x 8' (64 sq ft/luminaire)

27

84

0.9

MLB2S36LS26U Basic catalogue number :

Reference Data Efficiency Spacing Ratio

Application Data* 61.7% 1.6

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing FC VCP W/Sq Ft 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

85W .88

71

95

1.3

8' x 10' (80 sq ft/luminaire) 58

95

1.1

78

1.8

Ordering Guide Type Luminaire size Surface Parabolic

2’ x 4’

SO

120 Voltage :

Cells

Ballast :

Lamps qty/type

78 78 78

Options :

Catalogue number MLB2S78LS232 MLB2S78LS332 MLB2S78LS432

2-T8 3-T8 4-T8

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

70

8' x 8' x 8.5' Cubicle/60"Partition 8' x 8' (64 sq ft/luminaire)

40

97

1.3

MLB2S78LS432 Basic catalogue number :

*Average Footcandles Maintained Total LLF=BF (.88) x .85 = .75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

120 Voltage :

O4 Ballast :

Options :

73


Surface Luminaires

Prismalyte Surface 1’x 4’, 2’x 2’, 2’x 4’ (PNB) Premium Specification Surface Lens Luminaires PNB1SRFVA232120SO (Data)

PNB 1’ x 4’

5-1/2" (140 mm)

0

RCR

12" (305 mm) 600 60°

5-1/2" (140 mm) 12" (305 mm)

1200

5-1/2" (140 mm)

Premium design 5-1/2” deep welded surface box for minimum lamp image on lens surface.

SURFACE

Features •20 gauge welded steel housing. •Housing mitered corner detailing. •Only 5-1/2" deep. •Dual side wireways for cooler operation. •Quick remove ballast covers. •Fully enclosed wiring. •Door jamb with positive light stop. •Positive spring-loaded latches. •Available with floating doors. •Matches Prismalyte Plus troffer (see page 155). •Frames interchangeable with Parabaffle (see page 155). •Side mounted ballast

1800

12" (305 mm)

C. U.

1 2

63 56

3 4

51 46

5 6

41 38

7 8

34 31

9 10

28 25

30°

PNB2SRFVA26U120SO (Data)

PNB 2’ x 2’

0

RCR 5-1/2" (140 mm)

600 60°

24" (610 mm)

1200 5-1/2" (140 mm)

24" (610 mm) 1800 0°

PNB 2’ x 4’

C. U.

1 2 3 4 5 6

61 55 50 45 40 36

7 8

33 30

9 10

27 24

30°

PNB2SRFVA432120O4 (Data)

0 5-1/2" (140 mm)

24" (610 mm)

1200 60°

4 5 6 7 8 9 10

5-1/2" (140 mm)

24" (610 mm)

2400

5-1/2" (140 mm)

74

Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add as suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming 40W TT5: BX 40W TT5: SB 40W TT5: PB T8: OC 50W TT5: BE T8: PS 55W TT5: BF (not avail. in 347V) 3 LPB 40W TT5: X3 1 or 2 LPB T8: SO 3 LPB T8: O3 4 LPB T8: O4 For T12 lamp option see page 151. LPB : Number of lamps per ballast. Internal Fusing Consult your CFI Fluorescent representative. Electrical/Wiring Options For special wiring or emergency pack, consult factory. Stem and Canopy Sets Suspend luminaire 12", 18", 24", 36” and 48” from surface. (Four per luminaire is recommended.) catalogue Number: STKF12 (12"); STKF18 (18"); STKF24 (24"); STKF36 (36"); STKF48 (48") (White finish). Special Lenses VA lens is standard virgin acrylic. For other available lenses, see page 155.

3600

24" (610 mm) 0°

RCR 1 2 3

C. U. 64 57 52 46 41 37 34 30 27 25

30°

• T12 options are limited due to new regulations. Please consult factory for their availability. • Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forth by National Resources Canada.


Pendant and Surface Luminaires

Application Data*

Reference Data Efficiency Spacing Ratio

58.4% 1.2

Electronic Ballast Input Watts (120V) Ballast Factor

62W .88

Luminaire Spacing FC VCP W/Sq Ft

Ordering Guide Type

50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire) 46 66

0.9

8' x 10' (80 sq ft/luminaire) 42 64

0.8

Surface Luminaire

Luminaire size 1x4 1x4 1x4

Lamps qty/type

Catalogue number PNB1SRFVA132 PNB1SRFVA232 PNB1SRFVA332

1-T8 2-T8 3-T8

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire) 46 88

1.2

8' x 8' x 8.5' Cubicle/60"Partition 8' x 8' (64 sq ft/luminaire) 32 97

PNB1SRFVA232

0.9

Basic catalogue number : Premium Lensed Surface Luminaire

Application Data*

Reference Data Efficiency Spacing Ratio

57.3% 1.4

Electronic Ballast Input Watts (120V) Ballast Factor

60W .88

Luminaire Spacing FC VCP W/Sq Ft

Ordering Guide Type

50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire) 45 70

0.9

8' x 10' (80 sq ft/luminaire) 41 69

0.8

Surface Luminaire

Luminaire size 2x2 2x2 2x2

120 Voltage : 120 277 347

SO Ballast : See page 74

Lamps qty/type

Options : See page 74

Catalogue number PNB2SRFVA26U PNB2SRFVA32U PNB2SRFVA3FT

2-T8U6 3-T8U1.6 3-TT5

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire) 45 86

1.2

8' x 8' x 8.5' Cubicle/60"Partition 8' x 8' (64 sq ft/luminaire) 31 70

PNB2SRFVA26U

0.9

Basic catalogue number :

Application Data*

Reference Data Efficiency Spacing Ratio

60.2% 1.3

Electronic Ballast Input Watts (120V) Ballast Factor

112W .88

Luminaire Spacing FC VCP W/Sq Ft

Ordering Guide Type

50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire) 94

65

1.8

8' x 10' (80 sq ft/luminaire) 42

64

1.4

82

2.3

Surface Luminaire

Luminaire size 2x4 2x4 2x4

120

SO

Voltage :

Ballast :

Lamps qty/type

Options :

Catalogue number PNB2SRFVA232 PNB2SRFVA332 PNB2SRFVA432

2-T8 3-T8 4-T8

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire) 91

8' x 8' x 8.5' Cubicle/60"Partition 8' x 8' (64 sq ft/luminaire) 61

65

1.8

PNB2SRFVA432 Basic catalogue number :

120 Voltage :

04 Ballast :

Options :

The Prismalyte Surface Box is available with a regressed aluminum floating door.

RF

Regressed Aluminum Floating Door

* Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

75


Surface Luminaires

SLB Surface 1’x 4’, 2’x 2’, 2’x 4’ (SLB) Shallow Design Surface Lens Luminaire SLB1SFSVA232120SO (Data)

SLB 1’ x 4’

4" (102mm)

0

RCR

500

12"(305mm)

60°

1000

1536

High quality surface luminaires with 4" deep housings. Door frames are extruded aluminum or steel. SLB series surface luminaires can be used in low plenum depth areas that require surface luminaires. One-piece construction for maximum strength.

SURFACE

Features •Shallow 4" deep. •Positive cam-action latches secure frame on either side. •Centre mounted ballast compartment (2 lamps). •Snap-on wiring channel cover is removed without tools. •Matte black light seal on both ends to prevent light leaks. •Spot welded one-piece construction. •Match recessed luminaires serie AA, see page 155. Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming T8: OC 1 or 2 LPB T8: SO T8: PS 3 LPB T8: O3 (not avail. in 347V) 4 LPB T8: O4 For T12 lamp options see page 151. LPB : Number of lamps per ballast. Internal Fusing Consult your CFI Fluorescent representative. Electrical/Wiring Options For special wiring or emergency pack, consult factory. Stem and Canopy Sets Suspend luminaire 12", 18", 24", 36" or 48" from surface. (Four per luminaire is recommended.) catalogue Number: STKF12 (12"); STKF18 (18"); STKF24 (24"); STKF36 (36");STKF48 (48"). Special Lenses VA lens is standard virgin acrylic. For other available lenses, see page 155.

60 54

3 4

48 44

5 6

39 36

7 8

32 29

9 10

26 24

30°

SLB2SFSVA26U120SO (Data)

SLB 2’ x 2’

0

4" (102mm) 500

60°

24"(610mm)

1000

RCR 1 2 3 4 5 6 7 8 9 10

1355 0°

C. U. 68 61 54 49 44 39 36 32 29 26

30°

SLB2SFSVA432120O4 (Data)

SLB 2’ x 4’

0

4" (102mm) 24"(610mm)

1000 60°

3314 0°

RCR 1 2 3 4 5 6 7 8 9 10

2000

30°

Choice of two SLB door frames

FS

Flush Steel (Standard)

RA

Regressed Aluminum

Note: For Regressed Aluminium Door Frame, replace FS by RA in the basic catalogue number.

76

C. U.

1 2

C. U. 71 64 57 51 46 41 37 34 30 28


Pendant / Surface

Application Data*

Reference Data Efficiency Spacing Ratio

56.2% 1.2

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing FC VCP W/Sq Ft 50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

62W .88

50 66

0.9

8' x 10' (80 sq ft/luminaire) 40 63

0.8

Ordering Guide Type Door frame Surface Lens

Flush Steel

Luminaire size 1x4 1x4

Lamps qty/type 1-T8 2-T8

Catalogue number SLB1SFSVA132 SLB1SFSVA232

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

50 88

1.2

8' x 8' x 8.5' Cubicle/60"Partition 8' x 8' (64 sq ft/luminaire)

35 97

0.9

120

SLB1SFSVA132 Basic catalogue number : SLB Surface

Application Data*

Reference Data Efficiency Spacing Ratio

63.6% 1.3

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing FC VCP W/Sq Ft 50' x 70' x 8.5' Space 50 70

0.9

8' x 10' (80 sq ft/luminaire) 40 70

0.8

8' x 8' (64 sq ft/luminaire) 60W .88

Ordering Guide Type Door frame Surface Lens

Flush Steel

Voltage : 120 277 347

Luminaire size 2x2 2x2

Lamps qty/type 2-T8U6 4-T8

SO Ballast : See page 76

Options : See page 76

Catalogue number SLB2SFSVA26U SLB2SFSVA417

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

50 86

1.2

8' x 8' x 8.5' Cubicle/60"Partition 8' x 8' (64 sq ft/luminaire)

31 70

0.9

Basic catalogue number :

Application Data*

Reference Data Efficiency Spacing Ratio

67.1% 1.3

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing FC VCP W/Sq Ft 50' x 70' x 8.5' Space 105 65

1.8

8' x 10' (80 sq ft/luminaire) 84 64

1.4

8' x 8' (64 sq ft/luminaire) 112W .88

120

SO

Voltage :

Ballast :

SLB2SFSVA26U

Ordering Guide Type Door frame Surface Lens

Flush Steel

Luminaire size 2x4 2x4 2x4

Lamps qty/type 2-T8 3-T8 4-T8

Options :

Catalogue number SLB2SFSVA232 SLB2SFSVA332 SLB2SFSVA432

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

101 82

2.3

8' x 8' x 8.5' Cubicle/60"Partition 8' x 8' (64 sq ft/luminaire)

68 97

1.8

SLB2SFSVA432 Basic catalogue number :

120 Voltage :

O4 Ballast :

Options :

One-piece construction.

* Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

77


Surface Luminaires

Gymlyte 4’, 8’ (GM) Heavy Duty Surface Luminaire Gymlyte 4’ and 8’ narrow

GM4B4SVA232120SO (Data)

0

RCR

500 60°

Gymlyte 4’ wide body

1000

1517

SURFACE

Gymlyte features a spot welded construction, heavy gauge steel one-piece housing. It comes complete with wire guard or door frame with lens and wire guard. The wire guard is welded to the door frame when a door frame is specified. Specular reflectors are also available. All surfaces are post painted with white baked polyester enamel.

63 57

3 4

51 45

5 6

41 37

7 8

33 30

9 10

27 24

30°

Features • Welded 20 gauge chassis for superior strength. • Side mounted ballast for low 4-1/8” deep profile. • Wire guard or door, hinged. • Wire guard or door, latched with screw. • Stem or surface mounted. • Available with inside silver reflector. • Wireguard with or without door frame (see options). Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming T8: OC T8: SO T8: PS 3 LPB T8: O3 (not avail. in 347V) 4 LPB T8: O4 2 x 3 LPB T8: O6 For T12 option see page 151. LPB : Number of lamps per ballast. Door / Lens for Gymlyte When a lens is specified (e.g. VB), the unit is supplied with a steel door frame and heavy duty wire guard. When a lens is not required (e.g. XX), the unit is supplied with a heavy duty wire guard only. Electrical/Wiring Options Consult factory. Stem and Canopy Sets Order Catalogue Number STKF12 (12"), STKF18 (18"), STKF24 (24"), STKF36 (36"), STKF48 (48"). 4 Stem per luminaire is recommended.

78

C. U.

1 2

* See TriLyte at pages 102-104 for T5 Fluorescent Gym Application options


Pendant / Surface

Application Data*

Reference Data Efficiency Spacing Ratio

59.6% 1.2

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing FC 50' x 70' x 12' Space 12' on centre

62.0W .88

Ordering Guide Type Lamps qty/type

W/Sq Ft

56

1.2

71

1.3

61

1.2

60

1.4

50' x 70' x 8.5' Space 10' on centre 50' x 70' x 8.5' Space 12' on centre 30' x 30' x 8.5' Space 12' on centre

Lamp/Luminaire Nominal Length

Prismatic Lens Luminaire with Wireguard in Door Frame

2-T8 3-T8 3-T8 4-T8 4-T8 6-T8

48” 48” 48” 48” 96” tandem 96” tandem

Lens and Wireguard No Door Frame

2-T8 3-T8 3-T8 4-T8 4-T8 6-T8

48” 48” 48” 48” 96” tandem 96” tandem

120

GM4B4SVB232 Basic catalogue number : Gymlyte Luminaire

Voltage : 120 277 347

Luminaire Catalogue width number 12-15/16” GM4B4SVB232 12-15/16” GM4B4SVB332 16-15/16” GM4B5SVB332 16-15/16” GM4B5SVB432 12-15/16” GM8B4SVB232 12-15/16” GM8B4SVB332 12-15/16” GM4B4WGVB232 12-15/16” GM4B4WGVB332 16-15/16” GM4B5WGVB332 16-15/16” GM4B5WGVB432 12-15/16” GM8B4WGVB232 12-15/16” GM8B4WGVB332

SO Ballast : See below.

Options : See below Add appropriate suffix to catalogue number

Ordering Guide

GM Luminaire Type GM: Gymlyte

4 Luminaire Lenght 4: 4’ 8: 8’

B Body Style B: Surface Box

4 Width 4: 12-15/16” 5: 16-15/16”

S

VB

Ceiling Type S: Wireguard with Welded Door Frame WG: Wireguard with no door frame

Lens/Shielding VB: Pattern 12 lens .125” nominal - Prismatic lens. VX: Pattern 12 lens .125” polycarbonate. KA: Pattern 19 lens .156” nominal - Prismatic lens. XX: No lens with Wire Guard

2

32

Lamp Lamp/Type Quantity in a 32: T8 32W luminaire 34: T12 34W cross-section 2: 2 lamps 3: 3 lamps 4: 4 lamps

* Average Footcandles Maintained Total LLF=BF (.88) x .85 = .75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

120 Voltage 120 277 347

SO Ballast LE: T12 Magnetic OC: T8 Magnetic SO: 1-2 lamp Electronic O3: 3 LPB T8 Electronic O4: 4 LPB T8 Electronic O6: 2 x 3 LPB T8 Electronic

Options Add appropriate suffix to catalogue number see pages 78.

79


Surface Luminaires

Celebrity Surface (CBS) Premium Prismatic Surface Lens Luminaire CBS232120SO (Data)

Celebrity 12”x 49 9/16”

0

RCR 500 60°

3-1/4" (83 mm)

1000

12" (305 mm)

1817

A true high quality injection molded lens. Low glare optic with an architectural appearance and luminous ends.

C. U.

1 2

77 69

3 4

62 56

5 6

51 46

7 8

42 38

9 10

34 31

30°

SURFACE

Features • .187 lens thickness. • Five side injection molded refractor with square base, conical prisms (absolutely no sag). • Catadioptric side/end wall design, for low brightness. • Tight aligning refractor fit. • Invisible spring steel latches. • Easy ballast accessibility. • Rigid, reinforced housing. • Individual or continuous row mounting.

Director-2 (TH)

TH248-120LE (Data)

Director-2

Premium Wrap Surface Luminaire 0

4-1/8" (105mm) 8-5/8" (219mm)

500 60°

1000 1249

Features • A one-piece wrap lens with opaque end caps. • High lighting efficiency. • Suitable for surface or pendant mounting. • Ideal school luminaire. • Optional silver reflector

80

Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming T8: OC 1 or 2 LPB T8: SO T8: PS T12: LE 3 LPB T8: O3 (not avail. in 347V) 4 LPB T8: O4 For CBS with T12 see page 151. LPB : Number of lamps per ballast. Internal Fusing Consult your CFI Fluorescent representative. Electrical/Wiring Options For special wiring or emergency pack, consult factory. Canopy Spacer Suspends luminaire 1-1/2" from surface. Order Catalogue Number STSK. Stem and Canopy Order Catalogue Number STKF12 (12"), STKF18 (18"), STKF24 (24"), STKF36 (36"), STKF48 (48"). (White finish) Celebrity Surface not recommended for Stem Mounting. Lens Holophane 7100 lens standard. For pattern 19 : suffix KA. For parttern 12 : suffix VB.

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 73 65 58 52 46 42 37 33 30 27

30°

4-1/8" (105mm)

4-1/2" (114mm) 8-5/8" (219mm)

97" (2464mm)

13-5/8" (346mm)

48-1/2" (1232mm)

4-7/8" (124mm)

48-1/2" (1232mm)

97" (2464mm)

• T12 options are limited due to new regulations. Please consult factory for their availability. • Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forth by National Resources Canada.


Pendant / Surface

Application Data*

Reference Data Efficiency Spacing Ratio

73.1% 1.4

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing

W/Sq Ft

56

0.9

56

0.9

50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

62W .88

FC

30' x 30' x 8.5' Space 8' x 8' (64 sq ft/luminaire) 12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

64

1.2

Ordering Guide Type Luminaire width Surface Prismatic Luminaire

12"

Luminaire length

Lamps qty/type

Catalogue number

49-9/16"

2-T8

CBS232

120

CBS232 Basic catalogue number : Surface Prismatic Lens Luminaire

Voltage : 120 277 347

SO Ballast : See page 80

Options : See page 80

photograph illustrates action of Celebrity lens enclosure. Catadioptric prisms “mirror” out glare, refract ligh beams into useful areas. Sturdy steel chassis

Four sided injection molding

Reference Data Efficiency Spacing Ratio

72.7% 1.8

Luminaire Spacing

FC

W/Sq Ft

50' x 70' x 8.5' Space

Electronic Ballast Input Watts (120V) Ballast Factor

Application Data*

89.3W .88

8' x 8' (64 sq ft/luminaire)

54

0.9

53

0.9

Ordering Guide Type Lamps qty/type

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

59

Luminaire width

Prismatic Lens Luminaire

1-T8/T12 1-T8/T12 2-T8/T12 2-T8/T12 3-T8/T12 4-T8/T12

48” 48” 48” 48” 48” 48”

4 7/8” 8 5/8” 8 5/8” 13 5/8” 13 5/8” 13 5/8”

Tandem

2-T8/T12 2-T8/T12 4-T8/T12

96” Tandem 96” Tandem 96” Tandem

4 7/8” 4 7/8” 8 5/8”

30' x 30' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

Lamp/Luminaire Nominal length

1.2

TH248T Basic catalogue number :

120 Voltage :

Catalogue number TH148 TH1W8 TH248 TH2W8 TH348 TH448 † TH148T TH1W8T TH248T

04 Ballast :

Options :

† Consult factory, available in large quantity only.

* Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

81


Surface Luminaires

Dominaire Surface 4’ (TT) Specification Surface Wrap Luminaire TT248-120SO (Data)

0

RCR

2-5/8" (67 mm)

9" (229 mm)

500 60°

2-5/8" (67 mm)

1000

14" (356 mm)

SURFACE

Features • Step-back housing for an apparent depth of 1-1/2". • Floating panel of light effect. • A shallow profile and linear prismatic sides combine to reduce ceiling contrast. • Shielding hinges the unit’s entire length for safety and ease of maintenance. • Snap-on components provide time-saving installation. • Suitable for mounting on low-density cellulose fiberboard surfaces. • Not recommended for row mounting.

• T12 options are limited due to new regulations. Please consult factory for their availability. • Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forth by National Resources Canada.

2-5/8" (67 mm)

14" (356 mm)

1737 0°

180°

4-1/4" (107.9 mm)

54 48

5 6

43 39

7 8

35 32

9 10

29 26

30°

375 120°

125 0

4-1/4" (107.9 mm) 5-3/4" (146 mm)

150°

500

250

5-3/4" (146 mm)

90°

125 250

60°

375

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 77 67 59 52 46 41 37 33 30 27

500 0°

82

3 4

TN148-120SO (Data)

Narrow Surface Wrap Luminaire

• T12 options are limited due to new regulations. Please consult factory for their availability. • Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forth by National Resources Canada.

68 60

Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add as suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming T8: OC T8: SO T8: PS T12: LE 3 LPB T8: O3 (not avail. in 347V) 4 LPB T8: O4 LPB : Number of lamps per ballast. Electrical/Wiring Options For special wiring or emergency packs, consult factory. Canopy Spacer Suspends luminaire 1-1/2" from surface. Order catalogue number STSK. Stem and Canopy Sets Suspends luminaire 12", 18" 24", 36" or 48" from surface (Four per luminaire is recommended) .Order catalogue number STKF12 (12"), STKF18 (18"), STKF24 (24"), STKF36 (36"), STKF48 (48") (White finish). Internal Fusing Consult your CFI Fluorescent representative.

Dominaire Corridor 2’, 4’, 8’ (TN)

Features •A shallow profile and linear prismatic sides combine to reduce ceiling contrast. •Shielding hinges the unit’s entire length for safety and ease of maintenance. •Snap-on components provide time-saving installation. •Suitable for mounting on low-density cellulose fiberboard surfaces.

C. U.

1 2

30°

Options pages 150-156 Ballast Specify voltage (120, 277 in 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming T8: OC T8: SO T8: PS T12: LE 4 LPB T8: O4 (not avail. in 347V) LPB : Number of lamps per ballast. Electrical/Wiring Options For special wiring or emergency packs, consult factory. Canopy Spacer Suspends luminaire 1-1/2" from surface. Order catalogue number STSK. Stem and Canopy Sets Suspends luminaire 12", 18" 24", 36" or 48" from surface. Order catalogue number STKF12 (12"), STKF18 (18"), STKF24 (24"), STKF36 (36"), STKF48 (48"). (White finish) Internal Fusing Consult your CFI Fluorescent representative.


Pendant / Surface

Application Data*

Reference Data Efficiency Spacing Ratio

Luminaire Spacing

66.0% 1.2

W/Sq Ft

49

0.9

48

0.9

54

1.2

Ordering Guide Type Lamp qty/type

50' x 70' x 8.5' Space

Electronic Ballast Input Watts (120V) Ballast Factor

FC

8' x 8' (64 sq ft/luminaire) 62.0W .88

Prismatic 2-T8 / T12 Lens Luminaire

Lamp/Luminaire nominal length 48"

Luminaire Catalogue width number 9" TT248

30' x 30' x 8.5' Space 8' x 8' (64 sq ft/luminaire) 12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

120

TT248 Basic catalogue number : Dominaire Surface

Voltage : 120 277 347

SO Ballast : See page 82

Options : See page 82

TT448-120SO (Data) RCR

C. U.

1 2 3 4 5 6 7 8

69 61 54 49 43 39 35 32

9 10

28 26

Application Data*

Reference Data Efficiency Spacing Ratio

65.5% 1.3

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing

Lamp/Luminaire Luminaire Catalogue nominal length width number Prismatic 2-T8 / T12 48" 14" TT2W8 Lens 3-T8 / T12 48" 14" TT348 Luminaire 4-T8 / T12 48" 14" TT448

50' x 70' x 8.5' Space 8' x 10' (80 sq ft/luminaire) 83

112W .88

Ordering Guide Type Lamp qty/type

FC W/Sq Ft

1.4

30' x 30' x 8.5' Space 8' x 10' (80 sq ft/luminaire) 77

1.4

12' x 16' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

90

1.8

120

TT448 Basic catalogue number :

Application Data*

Reference Data Efficiency Spacing Ratio

81.0% 1.6

Luminaire Spacing

31.0W .88

W/Sq Ft

39

1,7

36

1.1

33

0.8

4' W x 8.5' H Corridor

Electronic Ballast Input Watts (120V) Ballast Factor

FC

6' W x 8.5' H Corridor

Ordering Guide Type Lamp qty/type Prismatic Lens Luminaire

Voltage :

Lamp/Luminaire nominal length

04 Ballast :

Options :

1-T8 / T12 2-T8 / T12 1-T8 / T12 2-T8 / T12 2-T8 / T12 (tandem)

24" 24" 48" 48" 96"

Luminaire Catalogue width number 5-3/4" TN124 5-3/4" TN224 5-3/4" TN148 5-3/4" TN248 5-3/4" TN148T

4-T8 / T12 (tandem)

96"

5-3/4"

8' W x 8.5' H Corridor

TN248 Basic catalogue number :

* Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

120

SO

Voltage :

Ballast :

TN248T

Options :

83


Surface Luminaires

Wrap 9”x 48”, 14”x 48” (TX) Prismatic Surface Wrap Lens Luminaire 9” x 48”

TX248-120SO (Data)

0

2-5/8" (67 mm)

RCR

9" (229 mm)

500 60°

SURFACE

Features •Floating panel of light effect. •A shallow profile and linear prismatic sides combine to reduce ceiling contrast. •Shielding hinges the unit’s entire length. •Snap-on components provide time-saving installation. •Suitable for mounting on low-density cellulose fiberboard surfaces. 9” wide 4’ nominal lengths. 14” wide 4’ nominal lengths. •Can be row mounted. Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming T8: OC T8: SO T8: PS T12: LE 3 LPB T8: O3 (not avail. in 347V) 4 LPB T8: O4 LPB : Number of lamps per ballast. Electrical/Wiring Options For special wiring or emergency packs, consult factory. Internal Fusing Consult your CFI Fluorescent representative. Canopy Spacer Suspends luminaire 1-1/2” from surface. Order catalogue number STSK. Stem and Canopy Suspends luminaire 12”, 18”, 24”, 36” or 48” from surface. Order catalogue number STKF12 (12”), STKF18 (18”), STKF24 (24”), STKF36 (36”), STKF48 (48”) (White finish). • T12 options are limited due to new regulations. Please consult factory for their availability. • Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forth by National Resources Canada.

1000

48" (1219 mm)

1549 0°

79 70

3 4

62 56

5 6

50 45

7 8

41 37

9 10

33 30

30°

TX448-120O4 (Data)

14” x 48”

0

3-3/16" (81mm)

RCR

14" (356 mm)

1000 60°

2000

48" (1219 mm)

2984 0°

1 2 3 4 5 6 7 8 9 10

90°

0

3-5/8" (92mm)

3/8" (10mm)

150

Surface Vandal Resistant Wrap Lens Luminaire

60° 250

26-1/8" 350

450 0°

• Heavy duty 16 gauge cold rolled steel housing. • Wall or ceiling mounts. • Clear injection molded polycabonate lens for toughness. • Lens secured with vandal-proof screws. • Easily removable ballast cover. • Polycarbonate lens only 3-5/8” deep, ideal for low ceilings. • 52.4% efficient. • Also available as a 2’ model.

30°

Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic RS T12: LE T8: OC

1 or 2 LPB T8: SO

LPB : Number of lamps per ballast. Electrical / Wiring Options Consult factory. Fluorescent Emergency Lighting System Factory installed emergency power battery pack with charger and inverter. Suffix : O.

• T12 options are limited due to new regulations. Please consult factory for their availability. • Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forth by National Resources Canada.

84

69 61 54 49 43 39 35 32 28 26

30°

8-1/4" (210mm)

Vandal 8”x 50” (VA)

Features

C. U.

VA248-12050 (Data)

8” x 50”

50-1/8"

C. U.

1 2


Pendant and Surface Luminaires

Application Data*

Reference Data Efficiency Spacing Ratio

76.0% 1.3

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing

W/Sq Ft

49

0.9

48

0.9

54

1.3

50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

62W .88

FC

30' x 30' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

Ordering Guide Type Lamp qty/type Prismatic Lens Luminaire

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

2-T8/T12

Lamp/Luminaire nominal length

Luminaire width

48"

9”

120

TX248 Basic catalogue number : Premium Wrap Low profile

Application Data*

Reference Data Efficiency Spacing Ratio

65.5% 1.3

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing

W/Sq Ft

83

1.4

77

1.4

90

1.8

50' x 70' x 8.5' Space 8' x 10' (80 sq ft/luminaire)

112W .88

FC

30' x 30' x 8.5' Space 8' x 10' (80 sq ft/luminaire)

Ordering Guide Type Lamp qty/type Prismatic Lens Luminaire

2-T8/T12 3-T8/T12 4-T8/T12

Voltage : 120 277 347

Catalogue number TX248

SO Ballast : See page 84

Options : See page 84

Lamp/Luminaire nominal length

Luminaire width

48" 48" 48"

14" 14" 14"

Catalogue number TX2W8 TX348 TX448

12' x 16' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

120

TX448 Basic catalogue number :

Ordering Guide Type Vandalism Wall / Surface Statique

Class/ division

Luminaire length

8” x 50” 8” x 50” 8” x 26”

1-T8 / T12 2-T8 / T12 2-T8 / T12

VA248 Basic catalogue number : Vandal Luminaire

* Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

Voltage :

120 Voltage : 120 277 347

04 Ballast :

Lamp type 48” 48” 24”

Options :

Catalogue number VA148 VA248 VA224

SO Ballast : See page 84

Options : See page 84 Add appropriate suffix to catalogue number

85


Surface Luminaires

Cubelite 24”, 36”, 48” (CSB, CSW, CTW) Surface / Wall Luminaire •Prismatic / Opal Lens CSW148-120LEZO (Data)

150

180°

120°

150°

RCR

100 50 90°

0 50

(CTW)

100 150

(CSW)

200

60°

250 300 350

SURFACE

Features • Only 4-3/4” deep. • Smooth opal acrylic diffuser standard (ZO). • Suitable for mounting on low density surfaces. • Individual or continuous row mounting. • Spring-loaded end cap (CSW and CSB only). • Also available with a clear prismatic lens (VB). • Convenience outlet optional. • Choice of white (CSW) or black (CSB) housing. • CTW features fixed encaps and prismatic lens

400

C. U.

1 2

68 58

3 4

51 44

5 6

39 34

7 8

31 27

9 10

25 22

30°

Options Ballast Specify voltage (120, 277 or 347) to surface strip fixture and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming T8: OC T8: SO T8: PS T12: LE (not avail. in 347V) For Cubelite consult factory on 2' length ballast options. Diffuser for Cubelite: Suffix ZO = Opal Acrylic (standard) VB = Prismatic Acrylic Electrical/Wiring Options For special wiring or emergency packs, consult factory. Internal Fusing Consult your CFI Fluorescent representative. Body colour Replace CSW (white) by CSB (black) in the basic catalogue number. For non spring-loaded end caps, replace CS by CT in the basic catalogue number.

• T12 options are limited due to new regulations. Please consult factory for their availability. • Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forth by National Resources Canada.

Cloud Bracket 24”, 36”, 48” (CCW) Surface / Wall Luminaire Decorative Diffuser

5-3/16" (132mm)

6" (152mm)

* 1-Lamp profile * Available in 1 and 2 lamp combinations Features •Soft diffused lighting provides even illumination in decorative residential and high-style commercial applications. •Soft curvature white acrylic diffuser. •Wall mounted design for bathroom, corridors or hallways. •Complementary design to the Belmont Cloud (see page 90). •Complete luminaire consists of Lens Assembly and Strip fixture. Order each item separately. •Not suitable for row mounting

86

Options pages 150-156 Ballast Specify voltage (120, 277 or 347V) to Surface Strip fixture and add suffix, e.g.120SO. Magnetic Electronic PowerSpec Dimming T8: OC T8: SO T8: PS (not avail. in 347V)

Ordering Guide Type

Length

Width

Height

Ordered With

Lamp Qty/Type

Catalogue Number

Cloud Bracket Diffuser

26-3/4" 38-3/4" 50-3/4"

6" 6" 6"

4-1/2" 4-1/2" 4-1/2"

SB1W2 SB1W3 SB1W4

1-T8 1-T8 1-T8

CCWLN2 CCWLN3 CCWLN4

Cloud Bracket Diffuser

26-3/4" 38-3/4" 50-3/4"

6" 6" 6"

4-1/2" 4-1/2" 4-1/2"

SB224 SB236 SB248

2-T8 2-T8 2-T8

CCWLN2 CCWLN3 CCWLN4

CCWLN Basic catalogue number: Cloud Bracket Lens

4 Length: 4'


Surface / Wall-Mount

Application Data*

Reference Data Efficiency Spacing Ratio

Luminaire Spacing

72.9% 1.7

W/Sq Ft

39

1,7

36

1.1

33

0.8

4' W x 8.5' H Corridor

62W .88

Ordering Guide Type Lamp qty/type Cubelite

Electronic Ballast Input Watts (120V) Ballast Factor

FC

6' W x 8.5' H Corridor

8' W x 8.5' H Corridor

1-T8/T12 2-T8/T12 1-T8/T12 2-T8/T12 1-T8/T12 2-T8/T12 1-T8/T12 2-T8/T12 1-T8/T12 2-T8/T12 1-T8/T12 2-T8/T12

Lamp/Luminaire nominal length

Luminaire width

24" 24" 36" 36" 48" 48" 24" 24" 36" 36" 48" 48"

4" 4" 4" 4" 4" 4" 4 5/16" 4 5/16" 4 5/16" 4 5/16" 4 5/16" 4 5/16"

Catalogue number CSW124 CSW224 CSW136 CSW236 CSW148 CSW248 CTW124 CTW224 CTW136 CTW236 CTW148 CTW248

SO

ZO

CTW only available in VB.

CSW124 Basic catalogue number : Cubelite

120 Voltage : 120 277 347

Ballast : See page 86

Options : ZO: Opal VB: Prismatic

Spring-loaded end cap (CSB and CSW).

Vanity Bracket 24”, 36”, 48” (CVW) 4-1/16" (103mm)

Surface / Wall Luminaire •Decorative Diffuser

4-11/16" (119mm)

* Only available in 1-lamp options Options pages 150-156 Ballast Specify voltage (120, 277 or 347V) to Surface Strip fixture and add suffix, e.g.120SO. Magnetic Electronic PowerSpec Dimming T8: OC T8: SO T8: PS (not avail. in 347V) Ordering Guide Type

Length

Width

Height

Ordered with

Lamp Qty/Type

Catalogue Number

Smooth White

25-3/8" 37-3/8" 49-3/8"

4-3/4" 4-3/4" 4-3/4"

4" 4" 4"

SB124 SB136 SB148

1-T8 1-T8 1-T8

CVWLN2-SW CVWLN3-SW CVWLN4-SW

Fluted White

25-3/8" 37-3/8" 49-3/8"

4-3/4" 4-3/4" 4-3/4"

4" 4" 4"

SB124 SB136 SB148

1-T8 1-T8 1-T8

CVWLN2-FW CVWLN3-FW CVWLN4-FW

Fluted Clear

25-3/8" 37-3/8" 49-3/8"

4-3/4" 4-3/4" 4-3/4"

4" 4" 4"

SB124 SB136 SB148

1-T8 1-T8 1-T8

CVWLN2-FC CVWLN3-FC CVWLN4-FC

CVWLN Basic catalogue number: Vanity Bracket Lens

4 Length: 4'

SW

Features •Choice of 3 basic modules and 3 distinctive acrylic variations in aesthetics and performance. Smooth White - accentuates the simplicity of a smooth, diffused surfaces Fluted White - features an elegant, fluted design with hint of opalescence Fluted Clear - emphasizes a bold fluted lens. •Molded ends. •Wall mounted. •Complete luminaire consists of Lens Assembly and Strip fixture. Order each item separately. •Not suitable for row mounting

Acrylic Variation: Smooth White

87


Pendant / Surface

Celebrity Wall 24”, 48” (CWBU) Premium Wall-Mount •Direct or Direct / Indirect Luminaire CWBU232120SO (Downlight Data)

Direct CWBU

0

RCR

3-1/16" (77.7 mm)

60° 500

7-5/8" (193.6 mm)

SURFACE

CWBU Series (Celebrity)...The ultimate in glare-free architectural lighting. A classic linear wall luminaire with a jewel-like diamond faceted injection molded refractor, that mirrors out brightness at critical viewing angles. Typical applications: Over mirrors, over bed, corridors, stairwells and bulletin boards. Features •Low brightness controlled downlighting or uplighting/downlighting. •Injection-molded one-piece virgin acrylic downlight refractor. •Removal of back panel allows in the field conversion of direct fixture to direct/indirect fixture. •Catadioptric side and end wall design downlight for low brightness. •Slim 3-1/16” height. •Nominal 2’ and 4’ lengths. •Invisible steel latches align refractor to housing. •Individual or continuous rows.

1233 0°

C. U.

1 2

65 57

3 4

51 46

5 6

41 38

7 8

34 31

9 10

29 27

30°

CWBU232120SO (Uplight / Downlight Data)

Direct / Indirect CWBU

180° 150°

RCR 1 2 3 4

512 120°

3-1/16" (77.7 mm) 90°

0

7-5/8" (193.6 mm) 60° 500

C. U. 65 57 51 45

5 6

37 33

7 8

30 28

9 10

26 24

LWB 24”, 36”, 48” (LWBU) Standard Wall Mount/Direct or Direct/Indirect Luminaire

871 0°

30°

LWBU232120SO (Downlight Data)

Direct LWBU

0

3-1/16" (77.7 mm) 500

7-5/8" (193.6 mm)

LWBU Series... A traditional linear wall luminaire with a crisp linear prismatic virgin acrylic refractor that controls brightness. Typical applications : over mirrors, over beds, corridors, stairwells and bulletin boards.

88

Features •Low brightness controlled downlighting or uplighting/downlighting. •Low brightness linear prismatic virgin acrylic refractor. •Slim 3-1/16” height. •Nominal 2’, 3’ and 4’ lengths. •Invisible steel latches align refractor to housing. •Removal of back plate allows in the field conversion of direct fixture into a direct/indirect fixture. •Individual or continuous rows. Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic T8: OC T8: SO For T12 consult factory. 2-Way Pull Switch (120V luminaires only.) Add suffix K (right position) or L (left position) to catalogue number. Grounded Convenience Outlet Add Suffix: CO. (Factory Installed). Electrical/Wiring Options For special wiring, fusing, electronic dimming ballasts or emergency packs, consult factory.

60°

1354

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 64 56 49 44 39 35 32 29 27 25

30°

LWBU232120SO (Uplight / Downlight Data)

Direct / Indirect LWBU

180° 150° 525 120°

3-1/16" (77.7 mm)

90°

0

7-5/8" (193.6 mm) 60° 500

954 0°

30°

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 64 56 49 44 39 35 32 29 26 24


Surface / Wall-Mount

Reference Data Efficiency

63%

Electronic Ballast Input Watts (120V) Ballast Factor

62.0W .88

Ordering Guide Type

Luminaire length

Lamp qty/type

Lamp length

Downlight

25-1/2" 49-1/2”

1-T8 1-T8

24” 48”

Downlight

25-1/2" 49-1/2”

2-T8 2-T8

24” 48”

CWBU117 Basic catalogue number : Celebrity Wall

120 Voltage : 120 277 347

Catalogue number CWBU117 CWBU132 CWBU217 CWBU232

SO Ballast : See page 88

Options : See page 88 Add appropriate suffix to catalogue number

Reference Data Efficiency

67.1%

Electronic Ballast Input Watts (120V) Ballast Factor

62.0W .88

Reference Data Efficiency

62.5%

Electronic Ballast Input Watts (120V) Ballast Factor

Ordering Guide Type

Luminaire length

Lamp qty/type

Lamp length

Downlight

25-1/2" 37-1/2” 49-1/2”

1-T8 1-T8 1-T8

24” 36” 48”

Downlight

25-1/2" 37-1/2” 49-1/2”

2-T8 2-T8 2-T8

24” 36” 48”

62.0W .88

LWBU132 Basic catalogue number :

120 Voltage :

Catalogue number LWBU117 LWBU125 LWBU132 LWBU217 LWBU225 LWBU232

SO Ballast :

Options :

Reference Data Efficiency

65.2%

Electronic Ballast Input Watts (120V) Ballast Factor

62.0W .88

89


Pendant / Surface

Surface Decorative Luminaires

Belmont I

1x4 10306 White Chassis (standard) 10324 Lightshield 10 3/4"-W 50 1/4"-L 3 1/2 "-H 2 - T12 / T8

Surface Wrap Luminaire

SURFACE

2x4 10310 White Chassis (standard) 10328 Lightshield 16"-W 50 1/4"-L 3 3/4 "-H 4 -T12 / T8

•Sleek wrap-around acrylic diffuser with opaque end caps. •Complete luminaire consists of Lightshield and Chassis. Order each item separately. •Not suitable for row mounting.

To complete catalogue no. e.g.: 1

10324 Lightshield

2

10306

-

Chassis

120

SO

Voltage

Ballast

Belmont II 1x4 10306 White Chassis (standard) 10326 Lightshield 10 5/8"-W 491/2"-L 3 7/8 "-H 2 -T12/T8

Surface Wrap Luminaire

2x4 10310 White Chassis (standard) 10330 Lightshield 155/8"-W 491/2"-L 3 7/8 "-H 4 -T12 / T8

•Linear acrylic trough with no visible trim. •Soft curved form. •Complete luminaire consists of Lightshield and Chassis. Order each item separately. •Not suitable for row mounting. Options pages 150-156 Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming T8 : OC T8 : SO T8 : PS T12 : LE 3 LPB T8 : O3 (not avail. in 347V) 4 LPB T8 : O4 LPB : Number of lamps per ballast. T12 not available for 13446 and 13448.

90

• T12 options are limited due to new regulations. Please consult factory for their availability. • Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forth by National Resources Canada.

To complete catalogue no. e.g.: 1

10326 Lightshield

2

10306 Chassis

-

120

SO

Voltage

Ballast


Pendant / Surface

1x4 10306 White Chassis (standard) 10325 Lightshield 133/4"-W 511/2"-L 4 "-H 2 -T12 / T8

2x4 10310 White Chassis (standard) 10327 Lightshield 17"-W 511/2"-L 4 "-H 4 -T12 / T8

•Acrylic diffuser with softly contoured edges. •Complete luminaire consists of Lightshield and Chassis. Order each item separately. •Not suitable for row mounting.

10325 Lightshield

2

Surface Wrap Luminaire

To complete catalogue no. e.g.: 10325 1

To complete catalogue no. e.g.: 1

Belmont Cloud

10306 Chassis

2 -

120

SO

Voltage

Ballast

Lightshield 10306 Chassis

120 Voltage

SO Ballast

Lumiplex 2x2 13222 Black Chassis 13554 Lightshield 26"-W 261/2"-L 3 7/8 "-H 2 -T8U6

Surface Wrap Luminaire

•Frameless acrylic diffuser has no visible hardware, swings down from either side for relamping. •Complete luminaire consists of Lightshield and Chassis. Order each number separately.

To complete catalogue no. e.g.: 13554 1 2

Lightshield 13222 Chassis

120 Voltage

SO Ballast

91


Industrial Luminaires

T5 Strip Series 22”, 34”, 46”, 92” (SV) Surface Strips 2 T5 Strip

SV4S228UNVPG

120°

150°

180°

RCR

90°

STRIPS

Features •Only 2” Wide. •Utilizes compact, high efficiency, T5 or T5HO lamps. •Fully enclosed wiring •Optional white or specular, symmetric and assymetric reflector. •Convenience outlet and switch K.O.s provided •Push through lamp holders with rotor for secure lamp retention. •Optional hangers and guards.

60°

30°

2 T5 Sidemount Strip

C. U.

1 2

90 77

3 4

67 59

5 6

52 46

7 8

41 37

9 10

33 30

SM4S228UNVPG

T5 Side-Mount Strip Series 22”, 34”, 46” (SM) Surface Side-Mount Strips 180°

120°

150°

90°

60°

Features •Only 1 3/8” deep. •Utilizes compact, high efficiency, T5 or T5HO lamps.. •Fully enclosed wiring •Convenience outlet and switch K.O.s provided (1 lamp only) •Push through lamp holders with rotor for secure lamp retention.

T5 Staggered Strip Series 26”, 38”, 50” (SS)

30°

RCR 1 2 3 4 5

C. U. 86 74 65 57 50

6 7

45 40

8 9

36 33

10

30

SS4S5228UNVPG

2 T5 Staggered Strip

180°

120°

150°

Surface Staggered Strips 90°

60°

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 88 76 66 58 50 45 40 36 32 29

30°

Features •Excellent for applications where continuous, even illumination is required.

Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120PI. Electronic T5 1 or 2 LPB Program Start: PG 1 or 2 LPB Instant Start: PI 1 or 2 LPB Power Spec Dimming (120/277V only): PF LPB: Number of lamps per ballast.

92

OPTIONS/ACCESSORIES Stem and canopy sets: Suspend luminaire 12”, 18”, 24”, 36”, or 48” from surface. (Two per luminaire is recommended. For 34” and 46” SVB Strip only.) Catalogue number : SV5F12 (12”); SV5F18 (18”); SV5F24 (24”); SV5F36 (36”); SV5F48 (48”) Chain hanging kit: Includes two 5’ heavy duty link chains with sturdy “V” hook for fixture suspension. (34” and 46” SVB Strip only.) Catalogue number: EE9HC Wire guard: Galvanized wire guard. Catalogue number: FOR SV STRIP T5 34”: SV5GXG3 FOR SV STRIP T5 46”: SV5GXG4 Reflectors: See pages 94-95. Rocker switch: Suffix: H (SV and 1 lamp SM only) Convenience outlet: Suffix: CO (SV and 1 lamp SM only)


Industrial Luminaires

Application Data*

Reference Data Efficiency Spacing Ratio

93.3% 1.5

Ordering Guide FC

W/Sq Ft

29

.45

36

.66

54

1.4

Type

50' x 70' x 8.5' Space STRIP T5

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing

12' on centre 60.0W 1.0

30' x 30' x 8.5' Space 10' on centre 12' x 16' x 8.5' Space 8' on centre

Nominal length

Number of lamp

T5

T5HO

22 1/2” 22 1/2” 34 1/4” 34 1/4” 46” 46” 92” 92”

1 2 1 2 1 2 2 (tandem) 4 (tandem)

SV2S114 SV2S214 SV3S121 SV3S221 SV4S128 SV4S228 SV8S128 SV8S228

SV2S124 SV2S224 SV3S139 SV3S239 SV4S154 SV4S254 SV8S154 SV8S254

UNV

SV4S228 Basic catalogue number : Strip T5

Reference Data Efficiency Spacing Ratio

Voltage : UNV (120/277V) 120 277 347

Type Side-mount Strip T5

66.0W 1.0

Number of lamp

T5

T5HO

22 1/2” 22 1/2” 34 1/4” 34 1/4” 46” 46”

1 2 1 2 1 2

SM2S114 SM2S214 SM3S121 SM3S221 SM4S128 SM4S228

SM2S124 SM2S224 SM3S139 SM3S239 SM4S154 SM4S254

UNV

Basic catalogue number : Side-mount Strip T5

Reference Data

PG

Voltage : UNV (120/277V) 120 277 347

Ballast : See page 92

Options : See page 92

Ordering Guide 93.3% 1.5

Type

Electronic Ballast Input Watts (120V) Ballast Factor

Options : See page 92

Nominal length

SM4S228

Efficiency Spacing Ratio

Ballast : See page 92

Ordering Guide 93.3% 1.5

Electronic Ballast Input Watts (120V) Ballast Factor

PG

66.0W 1.0

Staggered Strip T5

SS4S228 Basic catalogue number : Staggered Strip T5

Nominal length

Number of lamp

T5

T5HO

26 1/2” 26 1/2” 38 1/4” 38 1/4” 50” 50”

1 2 1 2 1 2

SS2S114 SS2S214 SS3S121 SS3S221 SS4S128 SS4S228

SS2S124 SS2S224 SS3S139 SS3S239 SS4S154 SS4S254

UNV Voltage : UNV (120/277V) 120 277 347

PG Ballast : See page 92

Options : See page 92

* Please ask your Canlyte Representative about the 90 deg. lamp mounted SM series T5 Luminaire.

* Average footcandles mounted total LLF Reflectance 60% ceiling, 50% wall, 20%. Floor T5 rated at 2610 lumens (25°C).

93


Industrial Luminaires

Symmetric Reflector T5 22”, 34”, 46” For 1 or 2 lamps T5 Strip (SV) SV5R1S4SSLD / SV4S154UNVPG

1 T5 Symmetric Silver

180°

120°

150°

RCR

90°

Features •Only 1 3/8” deep. •Installation on regular SV T5 strip, 1 or 2 lamps. •Available in white or high reflectivity specular finish. •Optional micro-perforated or slotted white reflector.

60°

30°

90 77

3 4

67 59

5 6

52 46

7 8

41 37

9 10

33 30

STRIPS

SV5R1W4SSLD / SV4S254UNVPG

2 T5 Symmetric White

180°

120°

150°

90°

60°

Asymmetric Reflector T5 22”, 34”, 46”

C. U.

1 2

30°

RCR 1 2 3 4 5

C. U. 86 74 65 57 50

6 7

45 40

8 9

36 33

10

30

SV5R1W4ASLD / SV4S154UNVPG

1 T5 Asymmetric White

For 1 or 2 lamps T5 Strip (SV) 180°

120°

150°

90°

60°

Features •Only 1 3/8” deep. •Installation on regular SV T5 strip, 1 or 2 lamps. •Available in white or high reflectivity specular finish.

C. U. 88 76 66 58 50 45 40 36 32 29

30°

SV5R1W4ASLD / SV4S254UNVPG

2 T5 Asymmetric White

180°

120°

150°

90°

60°

94

RCR 1 2 3 4 5 6 7 8 9 10

30°

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 86 75 65 57 50 45 40 36 32 29


Industrial Luminaires

Application Data*

Reference Data Efficiency Spacing Ratio

87,5% 1.9

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing

W/Sq Ft

25

.44

31

.64

30' x 30' x 8.5' Space 10' on centre 12' x 16' x 8.5' Space 8' on centre

47

Efficiency Spacing Ratio

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing

W/Sq Ft

50

.83

51

1.2

12' x 16' x 8.5' Space 8' on centre

84

Symetric Reflector SILVER

22 1/2” 34 1/4” 46” 92”

SV5R1W2SSLD** SV5R1W3SSLD** SV5R1W4SSLD** 2X SV5R1W4SSLD** SV5R1S2SSLD SV5R1S3SSLD SV5R1S4SSLD 2X SV5R1S4SSLD

Type

Luminaire Nominal Length

Reflector for T5 Strip*

Symetric Reflector WHITE

22 1/2” 34 1/4” 46” 92”

Symetric Reflector SILVER

22 1/2” 34 1/4” 46” 92”

SV5R1W2SSLD** SV5R1W3SSLD** SV5R1W4SSLD** 2X SV5R1W4SSLD** SV5R1S2SSLD SV5R1S3SSLD SV5R1S4SSLD 2X SV5R1S4SSLD

2.5

Lamp rated at 4400 lumens

Reference Data

* Use with 1 or 2 T5 Strip (SV) ** For Slotted White Reflector, replace Solid White SLD by SLT ** For Microperforated White Reflector, replace Solid White SLD by PER

Ordering Guide 91.8% -

Electronic Ballast Input Watts (120V) Ballast Factor

22 1/2” 34 1/4” 46” 92”

Ordering Guide FC

30' x 30' x 8.5' Space 10' on centre

Efficiency Spacing Ratio

Symetric Reflector WHITE

50' x 70' x 8.5' Space 12' on centre

121W 1.0

Reflector for T5 Strip*

* Use with 1 or 2 T5 Strip (SV) ** For Slotted White Reflector, replace Solid White SLD by SLT ** For Microperforated White Reflector, replace Solid White SLD by PER

Application Data* 78.7% 1.4

Luminaire Nominal Length

1.3

Lamp rated at 2610 lumens

Reference Data

Type

50' x 70' x 8.5' Space 12' on centre

64W 1.0

Ordering Guide FC

64W 1.1

Type

Luminaire Nominal Length

Asymetric Reflector WHITE

22 1/2” 34 1/4” 46” 92”

Asymetric Reflector SILVER

22 1/2” 34 1/4” 46” 92”

Reflector for T5 Strip* SV5R1W2ASLD SV5R1W3ASLD SV5R1W4ASLD 2X SV5R1W4ASLD SV5R1S2ASLD SV5R1S3ASLD SV5R1S4ASLD 2X SV5R1S4ASLD

*Use with 1 or 2 T5 Strip (SV)

Reference Data Efficiency Spacing Ratio

Ordering Guide 85.8% -

Electronic Ballast Input Watts (120V) Ballast Factor

121W 1.0

Type

Luminaire Nominal Length

Asymetric Reflector WHITE

22 1/2” 34 1/4” 46” 92”

Asymetric Reflector SILVER

22 1/2” 34 1/4” 46” 92”

Reflector for T5 Strip* SV5R1W2ASLD SV5R1W3ASLD SV5R1W4ASLD 2X SV5R1W4ASLD SV5R1S2ASLD SV5R1S3ASLD SV5R1S4ASLD 2X SV5R1S4ASLD

*Use with 1 or 2 T5 Strip (SV), see pages 92-93.

* Average footcandles mounted total LLF = .90 Reflectance 80% ceiling, 50% wall, 20% Floor T5 rated at (25°C).

95


Industrial Luminaires

Surface Strip SB Series Narrow / Wide Strips SB148-120SO (Data)

Narrow Strip

180°

120°

150°

RCR

3" (76.2 mm)

90°

1-5/8" (41.2 mm)

2.7" (67 mm)

60°

Created with the installer in mind, the strip incorporates labor saving and solid design features. Time saving flip-on end caps and ballast covers install quickly. Strengthening ribs ensure uniformity and stability of the channel housing. It’s quality lighting that will save you time and dollars.

STRIPS

• T12 options are limited due to new regulations. Please consult factory for their availability. • Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forth by National Resources Canada.

96

3 4

62 54

5 6

47 42

7 8

37 33

9 10

30 27

SB296H-120LE (Data) 4-5/8" (117.4 mm) 2-1/2" (63.5 mm)

3.75" (95 mm)

180°

120°

150°

RCR 1 90°

4-5/8" (117.4 mm) 60°

2-1/2" (63.5 mm)

3.75" (95 mm)

Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic 4' T12: LE 1 or 2 LPB T8: SO 3 LPB T8: O3 SL T12: LE† 4 LPB T8: O4 (4' lamp only) HO T12: LE† T8: OC 2 x 3 LPB T8: O6 † Available only for 8’. For T12 HO 4’ leave blank. LPB : Number of lamps per ballast. Electrical/Wiring Options For special wiring, fusing, electronic dimming ballasts or emergency packs, consult factory. Optional hangers, wire guards and aligners, see page 155.

84 71

30°

Strip HO

Features •Flip-up end caps and snap-on ballast cover. •2-3/4" wide housing channel (1 lamp). •4-1/4" wide housing channel (1 - 2 lamp). •Fully enclosed wiring. •Screwdriver slot for easy ballast cover removal. •Combination end-cap for continuous row mounting. •Optional hangers, wire guards. •Available with Symmetrical and Asymmetrical reflectors (order separately) (see pages 98-99).

C. U.

1 2

Wide Strip

180°

1-5/8" (41mm)

90°

1-7/8" (48mm)

60°

9-1/4" (235mm)

9-1/4" (235mm) 2-3/4" (70 mm)

4 5

57 50

6 7

44 40

8 9

35 32

10

29

120°

150°

4-1/4" (108mm)

2-3/4" (70 mm)

75 65

SB296S-120LE (Data) 1-5/8" (41mm)

2-3/4" (70 mm)

2 3

30°

4-1/4" (108mm)

2-3/4" (70 mm)

C. U. 87

1-7/8" (48mm)

30°

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 87 75 65 57 50 44 40 35 32 29


Industrial Luminaires

Application Data*

Reference Data Efficiency Spacing Ratio

89.5% 1.6

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing

W/Sq Ft

48

1.4

50

1.1

37

1.1

Type

Nominal length

Lamps watts/type

Narrow Strip†

18" 18" 24” 24” 36” 48” 72” 96”

1-T12 LPF 1-T12/T8 1-T12LPF 1-T12/T8 1-T12/T8 1-T12/T8 2-T12/T8 (tandem) 2-T12/T8 (tandem)

50' x 70' x 8.5' Space 10' on centre

30.0W .88

Ordering Guide FC

30' x 30' x 8.5' Space 8' on centre 12' x 16' x 8.5' Space 6' on centre Lamp rated at 3000 lumens

120

SB148T Basic catalogue number : Surface Strip 2 lamps (Tandem)

Application Data*

Reference Data Efficiency Spacing Ratio

89.7% 1.6

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing

FC

W/Sq Ft

99

2.6

79

2.2

109

2.6

50' x 70' x 12' Space 16' on centre

SO Ballast : See page 96

Options : See page 96

Ordering Guide Type

Nominal length

Lamps watts/type

Deep Strip

48" 96"

1 or 2-T12HO/T8HO 1 or 2-T12HO/T8HO

50' x 70' x 12' Space 12' on centre

257.0W .95

Voltage : 120 277 347

One lamp SB118L SB118 SB124L SB124 SB136 SB148 SB136T SB148T (tandem)

One lamp SB148H SB196H

Two lamp SB248H SB296H

50' x 70' x 8.5' Space 12' on centre

12' on centre

90

2.6

FC

W/Sq Ft

120

SB148H

30' x 30' x 8.5' Space

Basic catalogue number :

Voltage :

Ballast :

Options :

Lamp rated at 8800 lumens

Application Data*

Reference Data Efficiency Spacing Ratio

89.7% 1.6

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing 50' x 70' x 12' Space 12' on centre

160W .96

Ordering Guide

69

1.6

88

1.9

50' x 70' x 8.5' Space 10' on centre

Type

Nominal Lamps length watts/type

Wide Strip

24" 36" 48" 96"

T12/T8 T12/T8 T12/T8 T12/T8

30' x 30' x 8.5' Space 8' on centre

87

2.1

96"

T12 SL/T8 SL

One lamp SB1W2 SB1W3 SB1W4 SB1W4T

Two lamp SB224 SB236 SB248 SB248T

Three lamp

Four lamp

SB348 SB348T

SB448 SB448T

2 lamps tandem

4 lamps tandem

6 lamps tandem

8 lamps tandem

SB196S

SB296S

( )( )( )( ) SB496S

SL : Slimline Lamp rated at 6100 lumens

SB248T Basic catalogue number :

* Average Footcandles Maintained Total LLF = .75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor.

120 Voltage :

04 Ballast :

Options :

97


Industrial Luminaires

Staggered Strip Surface Strips STG4132HPF120SO (Data)

1 lamp

180°

150° RCR 120°

4-1/4" (107.9 mm) 1-7/8" (47.6 mm)

90°

4-3/8" (111 mm)

42" (1067 mm)

STRIPS

Features •Full 3" over lap. Eliminates shadows from lamp ends. •Housing only 1-7/8" deep. •Safe-handling metal edges. •Fully enclosed wireway. •Excellent for applications where continuous, even illumination is required.

48" (1219 mm)

60°

180°

4-1/4" (107.9 mm)

120°

51" (1295 mm)

48" (1219 mm)

60°

4-3/8" (111 mm)

1 Lamp

2-3/4" (69.8 mm)

180°

7 8

37 33

9 10

30 27

RCR 1

C. U. 87

2 3

75 65

4 5

57 50

6 7

44 40

8 9

35 32

10

29

150° 120°

90°

2-3/4" (69.8 mm) 60°

1-7/8" (47.6 mm) 0°

98

47 42

CSM4132HPF120SO (Data)

2 Lamp

Options pages 150-156 Electrical/Wiring Options For special wiring, fusing, dimming, or electronic ballasts, consult factory. Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic T8: OC 1 or 2 LPB T8: SO For T12 lamp see page 151. LPB : Number of lamps per ballast. Consult factory on 2' and 3' length ballast options.

5 6

30°

1-7/8" (47.6 mm)

Features •Four sizes: 18”, 24", 36", 48". •Fully enclosed wiring. •Only 1-7/8" deep.

62 54

150°

90°

Surface Strips

3 4

30°

1-7/8" (47.6 mm)

Side-Mount Strip

84 71

STG4232HPF120SO (Data)

2 Lamp

Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic T8: OC 1 or 2 LPB T8: SO 4 LPB T8: O4 For T12 lamp see page 151. LPB : Number of lamps per ballast. Consult factory on 2' and 3' length ballast options. Electrical/Wiring Options For special wiring, fusing, electronic dimming ballasts or emergency packs, consult factory.

C. U.

1 2

30°

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 84 71 62 54 47 42 37 33 30 27


Industrial Luminaires

Ordering Guide

Reference Data Efficiency Spacing Ratio

89.5% 1.6

Electronic Ballast Input Watts (120V) Ballast Factor

30.0W .88

Type

Luminaire length

Lamp length

Lamp qty

Staggered Channel Strip (One Lamp in Width)

24" 36" 48" 69" 93"

2' 3' 4' 3' 4'

1-T8 1-T8 1-T8 2-T8 Tandem 2-T8 Tandem

120

STG4132HPF Basic catalogue number : Staggered Strip 1 lamp

SO

Voltage : 120 277 347

Ballast : See page 98

Reference Data

Ordering Guide

Efficiency Spacing Ratio

Type

Luminaire length

Lamp length

Lamp qty

Staggered Channel Strip (Two Lamps in Width)

27" 39" 51" 75" 99"

2' 3' 4' 3' 4'

2-T8 2-T8 2-T8 4-T8 Tandem 4-T8 Tandem

89.7% 1.6

Electronic Ballast Input Watts (120V) Ballast Factor

62.0W .88

120

STG4232HPF Basic catalogue number :

89.5% 1.6

Electronic Ballast Input Watts (120V) Ballast Factor

Options : See page 98 Add appropriate suffix to catalogue number

Cat. number with T8 lamp STG2217HPF STG3225HPF STG4232HPF STG6225HPF STG8232HPF

SO

Voltage :

Ballast :

Options :

Ordering Guide

Reference Data Efficiency Spacing Ratio

Cat. number with T8 lamp STG2117HPF STG3125HPF STG4132HPF STG6125HPF STG8132HPF

30.0W .88

Type

Luminaire length

Lamp length

Lamp qty

Side-Mount Strip (One Lamp)

24" 36" 48"

– – –

1-T8 1-T8 1-T8

Side-Mount Strip (Two Lamp)

24" 36" 48"

– – –

2-T8 2-T8 2-T8

CSM4232HPF

SO

120

Basic catalogue number :

Cat. number with T8 lamp CSM2117HPF CSM3125HPF CSM4132HPF CSM2217HPF CSM3225HPF CSM4232HPF

Voltage :

Ballast :

Options :

Ordering Guide

STG

4

2

32

HPF

120

SO

Luminaire Type

Luminaire Lenght 2 = 2’ 3 = 3’ 4 = 4’ 6 = 6’ 8 = 8’

Number of lamps in a luminaire cross-section 1 2

Lamp Type 17 = T8 2’ 25 = T8 3’ 32 = T8 4’ 20 = T12 2’ 25 = T12 3’ 34 = T12 4’

HPF

Voltage 120 277 347

Ballast OC: Magnetic T8 SO: 1 or 2 T8 Electronic O4: 4 LPB T8 Electronic LE: Magnetic Energy Saving

STG CSM

Options See pages 98.

99


Industrial Luminaires

Specular Reflectors SB9R21S-48 (Reflector) with SB148-120SO (Strip)

Narrow Spacing - Specular Reflector

SB9R21S-48 (Data) 0

RCR

C. U.

1 2

98 88

3 4

79 72

900

5 6

64 59

1200

7 8

53 48

1500

9 10

44 41

300

600

60°

1700 0°

INDUSTRIAL

The SB9R specular reflector series provides very high efficiencies and is well suited for hard-to-light areas such as gymnasiums and aisles, and for task lighting. Suitable for low or high ceilings, these reflectors provide an economical lighting solution. Features •High specular silver film material with white painted steel back. •Specular reflector mounts on regular SB series strips. See pages 96-97 (specify strip and reflector part numbers). •For wire guard option consult Factory. •Suitable for continuous row mounting. •Different spacing ratios available (narrow and wide).

30°

Wide Spacing - Specular Reflector

SB9R14S-48 (Data) 0

RCR 1

300

600

2 3 4 5 6 7 8 9 10

60°

900

1200

SB9R14S-48 (Reflector) with SB248-120SO (Strip) 1500 1650

30°

C. U. 95 82 72 64 56 50 45 41 37 33

White Reflector

5" (127 mm)

7-1/4" (184 mm)

SB9R1-XX 6" (152 mm)

5" (127 mm)

SB9R16-XX

(

3" (76 mm) 6-3/4" (171 mm)

6-3/4" (171 mm) 6-1/2" (165 mm)

White Reflectors

SB9R2-XX

6-1/2" (165 mm)

SB9R2-XXSLT

White reflectors are suited only to Strips (see pages 94-95).These reflectors come in a wide variety of symmetrical and asymmetrical versions. Compatibility of white reflectors with wide SB1W Strips: Use reflectors for 2 lamps Strips (e.g. SB1W8 Strip will require white reflector SB9R6-48).

5" (127 mm) 7-1/2" (191 mm)

100

xx = Length of luminaire.

7-1/2" (191 mm)

SB9R6-XXSLT

4-1/4" (108 mm)

5" (127 mm)

XSLT

5" (127 mm)

SB9R6-XX

6" (152 mm)

SB9R8-XX

3" (76 mm)

SB9R1-XX90


Industrial Luminaires

Application Data*

Reference Data Efficiency Spacing Ratio

Luminaire Spacing

91.2% .7

FC

W/Sq Ft

71

1.1

69

1.1

72

1.4

50' x 70' x 8.5' Space 8' on centre 30' x 30' x 8.5' Space 8' on centre

Ordering Guide Type Luminaire length Specular Industrial Reflector

24” 36” 48” 96”

Lamps qty/type

Reflector catalogue number SB9R21S-24 SB9R21S-36 SB9R21S-48 2-SB9R21S-48

1 1 1 2 (tandem)

For use with the narrow strip series. See pages 96-97.

12' x 16' x 8.5' Space 6’ on centre

Reference Data Efficiency Spacing Ratio

Ordering Guide

Application Data* Luminaire Spacing

92.3% 1.3

FC

W/Sq Ft

Type

Luminaire length

Lamps qty/type

86

1.2

Specular Industrial Reflector

24” 36” 48” 96”

2 2 2 4 (tandem)

91

1.2

126

1.9

50' x 70' x 12' Space 12' on centre 50' x 70' x 8.5' Space 12' on centre

Reflector catalogue number SB9R14S-24 SB9R14S-36 SB9R14S-48 2-SB9R14S-48

For use with the wide strip series. See pages 96-97.

30' x 30' x 8.5' Space 8’ on centre

Ordering Guide White Reflector Length Lamp qty/type

Reflector catalogue No.

Length Lamp qty/type

Reflector catalogue No.

Length Lamp qty/type

Reflector catalogue No.

Length Lamp qty/type

Reflector catalogue No.

24” 24” 24” 24” 24” 24” 24” 24”

SB9R1-24 SB9R2-24 SB9R16-24 SB9R1-24-90 SB9R2-24-SLT SB9R6-24 SB9R8-24 SB9R6-24-SLT

36” 36” 36” 36” 36” 36” 36” 36”

SB9R1-36 SB9R2-36 SB9R16-36 SB9R1-36-90 SB9R1-36-SLT SB9R6-36 SB9R8-36 SB9R6-36-SLT

48” 48” 48” 48” 48” 48” 48” 48”

SB9R1-48 SB9R2-48 SB9R16-48 SB9R1-48-90 SB9R2-48-SLT SB9R6-48 SB9R8-48 SB9R6-48-SLT

96” 96” 96” 96” 96” 96” 96” 96” 96” 96” 96”

SB9R1-48 X2 SB9R2-48 X2 SB9R16-48 X2 SB9R1-48-90 X2 SB9R2-48-SLT X2 SB9R6-48 X2 SB9R8-48 X2 SB9R6-48-SLT X2 SB9R6-96S† SB9R8-96S† SB9R6-96S-SLT†

1 1 1 1 1 2 2 2

1 1 1 1 1 2 2 2

1 1 1 1 1 2 2 2

*Average Footcandles Maintained Total LLF= .75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 2900 lumens.

2 tandem 2 tandem 2 tandem 2 tandem 2 tandem 4 tandem 4 tandem 4 tandem 1 or 2-SLHO 1 or 2-SLHO 1 or 2-SLHO

Note: On 8-foot Slimline Reflector the Part Number comes in a kit with 2 x 4-foot Reflector and centre Brackets.

101


Industrial Luminaire

TriLyte Narrow-Body 2-, 3-, 4-Lamp Lowbay Surface/Pendant Luminaire FH4C4DXX454120CV (Data) 0

17’’ 2-3/4’’ 13-3/8’’

60° 4000

8000

Options pages 150-156 Ballast Specify voltage (120, 277, UNV, 347) and add suffix, e.g. 120PU. O4 = T8 Elect. One 4-lamp I.S. THD<20%. O5 = T8 Elect. One 4-lamp and one 2-lamp I.S. THD<20%. O7 = T8 Elect. I.S. One 4-lamp to operate outside lamps. One 4-lamp to operate inside lamps. THD<20%. PI = T5 Elect. I.S. One 2-lamp. THD<10%. PG =T5HO Elect. P.S. One 2-lamp. THD<10%. PU =T5HO Elect. P.S. One 3-lamp. THD<10%. PV = T5HO Elect. P.S. One 4-lamp. THD<10%. P6 = T5HO Elect. P.S. One 4-lamp ballast to operate outside lamps. One 2-lamp ballast to operate inside lamps. THD<10%. P7 = T5HO Elect P.S. One 3-lamp ballast to operate lamps 1, 3 and 5. One 3-lamp ballast to operate lamps 2, 4 and 6. THD<10%. P8 = T5HO Elect. P.S. One 4-lamp to operate outside lamps. One 4-lamp to operate inside lamps. THD<10%. Consult your Canlyte representative for other ballast options. Wireguard/Lens Variety of shielding options available (see photos opposite). al Fusing Suffix F. Interna Electrical/Wiring Options Consult your Canlyte representative. Stem and Canopy Sets 4 stems required per luminaire. Order catalogue number STKF12 (12"), STKF18 (18"), STKF24 (24"), STKF36 (36"), STKF448 (48"). Chain Hanger Kit 2 kits required per luminaire. Order catalogue number EE9HC. Luminaire-Mounted Motion Sensor 360° coverage. Field installed. Only available on luminaires with contoured specular reflectors. Order catalogue number FH360-120 / FM360-277 / FH360-347. Reemote-Mounted Motion Sensor Narrow coverage. Field installed. Order catalogue number FH110. Used with PowerPack, order catalogue number FHP20-120* (120V)/ FMP20-277 (277V)/ FHP20-347 (347V). * See factory for specifications

17’’

17’’

88 82

4 5

76 70

6 7

66 60

8

56

9 10

52 48

98-1/4’’

36’’

49-1/2’’

Narrow-Body 8’

8-3/4’’

96

2 3

36’’

Features •Sturdy one-piece post-painted housing providing clean, smooth, installation-friendly corners. •Side-mounted ballast for low 2-3/4" profile. •Mounting heights from 12' to 45' with suitable lamping-reflectorlens selection. •2-, 3- and 4-lamp versions (cross-section view). •Available in 4' and 8' lengths. •Choice of contoured specular, flat specular or flat white reflector. •Contoured specular reflector offers optimum performance and 95% reflectivity (not available on 2-lamp model). •Choice of stem, surface or chain mounting. •Accepts emergency battery packs. •Available motion sensor allows for total lighting control, added energy savings (see page 155).

CU

30°

Narrow-Body 4’

36’’

INDUSTRIAL 102

Designed for Trade (commercial spaces), Recreational and Industrial locations, TriLyte provides much needed versatility in lowbay applications. Using the appropriate lamp, wattage and reflector options, this narrow-body version is also suitable for highbay lighting, particularly retail outlets and indoor sports facilities. Its low-profile housing (almost 1" shallower than most competing models) is perfect for areas that place a premium on luminaire appearance. Dual-circuit TriLyte equipped with optional motion sensor delivers added lighting control flexibility for industrial applications.

RCR 1

8-3/4’’

WW: White hinged wireguard only (no lens), 9-gauge wire adding rigidity to luminaire.

VA: Pattern 12 prismatic lens made of virgin acrylic (.095" nominal). Complete with hinged white wireguard.

XX: Version without lens shielding. xx = Luminaire Length.

VB: Pattern 12 prismatic lens made of virgin acrylic (.125" nominal). Complete with hinged white wireguard.


Industrial Luminaires

Application Data*

Reference Data Efficiency Spacing Ratio

86.2% 1.2

Electronic Ballast Input Watts (120V) Ballast Factor

234W 1.00

Ordering Guide - T5

Luminaire Spacing

FC

W/Sq Ft

300' x 400' x 25' Space 17’ on centre

50

0.81

120' x 80' x 28' Space 16’ on centre

55

0.98

300' x 400' x 25' Space 14’ on centre

75

1.15

Luminaire-Mounted Motion Sensor 360° coverage. Field installed. Catalogue Number FH360-120 / FH360-

277 / FH360-347.

Remote-Mounted Motion Sensor. Narrow coverage. field installed. Catalogue Number FH110. This sensor is sold in conjunction with a Power pack # FHP20-120 (120 V), FHP20-277 (277 V) or FHP20-347 (347 V), please order accordingly.

Type

Lamps qty/type

Lamp/Luminaire Nominal Length

Luminaire width

Catalogue number

Prismatic Lens (VB) With Wireguard

2-T5HO 3-T5HO 4-T5HO 6-T5HO 8-T5HO

48" 48" 48" 96" tandem 96" tandem

17" 17" 17" 17" 17"

FH4W4DVB254 FH4C4DVB354 FH4C4DVB454 FH8C4DVB354 FH8C4DVB454

White Wireguard With No Lens

2-T5HO 3-T5HO 4-T5HO 6-T5HO 8-T5HO

48" 48" 48" 96" tandem 96" tandem

17" 17" 17" 17" 17"

FH4W4DWW254 FH4C4DWW354 FH4C4DWW W454 FH8C4DWW354 FH8C4DWW454

Ordering Guide - T8 Type

Lamps qty/type

Lamp/Luminaire Nominal Length

Luminaire width

Catalogue number

Prismatic Lens (VB) With Wireguard

2-T8 3-T8 4-T8 6-T8 8-T8

48" 48" 48" 96" tandem 96" tandem

17" 17" 17" 17" 17"

FH4W4DVB232 FH4C4DVB332 FH4C4DVB432 FH8C4DVB332 FH8C4DVB432

White Wireguard With No Lens

2-T8 3-T8 4-T8 6-T8 8-T8

48" 48" 48" 96" tandem 96" tandem

17" 17" 17" 17" 17"

FH4W4DWW232 FH4C4DWW332 FH4C4DWW W432 FH8C4DWW332 FH8C4DWW432

UNV

FH4W4DWW454 Basic catalogue number: TriLyte Luminaire

Voltage: 120 277 347

PV Ballast: See below.

Options: See below Add appropriate suffix to catalogue number

Numbering Logic

FH Luminaire Type FH: TriLyte

4 Luminaire Length 4: 4’ 8: 8’

W Body Style W : Flat Design White Reflector C : Contoured Specular Reflector S : Flat Design Specular Reflector

4 Width 4: 17’’

D Type D: Downlight

WW hielding Lens/Sh VA: Prismatic Lens VA with Wireguard VB: Prismatic Lens VB with Wireguard WW: Wireguard, White /No Lens XX: No Shielding

4 Lamp Quantity in a luminaire cross-section 2: 2 lamps 3: 3 lamps 4: 4 lamps

54

UNV

Lamp/Type 28: T5 28W 32: T8 32W 54: T5HO 54W

Voltage 120 277 UNV 347

Acronyms Used CU: Coefficients of Utilization FC: Footcandles IS: Instant Start LLF: Light Loss Factor PS: Program Start RCR: Room Cavity Ratio THD: Total Harmonic Distortion

* Average Footcandles Maintained. Total LLF = 0.84. Reflectance: 80% Ceiling, 50% Wall, 20% Floor. 54W T5HO lamp rated at 4400 lumens at 25oC.

PV Options Add appropriate suffix to catalogue number see pages 150-156

Ballast O4 = T8 Elect. One 4-lamp I.S. THD<20% O5 = T8 Elect. One 4-lamp and one 2-lamp I.S. THD<20% O7 =T8 Elect. I.S. One 4-lamp/outside lamps. One 4-lamp/inside lamps. THD<20%. PI = T5 Elect. I.S. One 2-lamp I.S., THD<10% PG = T5HO Elect. P.S. One 2-lamp, THD<10% PU = T5HO Elect. P.S. One 3-lamp, THD<10% PV = T5HO Elect. P.S. One 4-lamp, THD<10% P6 = T5HO Elect. P.S. One 4-lamp/outside lamps. One 2-lamp/inside lamps. THD<10% P7 = T5HO Elect P.S. One 3-lamp ballast for lamps 1, 3 and 5, One 3-lamp ballast for lamps 2, 4 and 6, THD<10% P8 = T5HO Elect. P.S. One 4-lamp/outside lamps. One 4-lamp/inside lamps. THD<10%

103


Industrial Luminaire

TriLyte Wide-Body 6-Lamp Highbay Surface/Pendant Luminaire FH4C5DXX654UNVPG (Data)

0

23-1/8’’ 2-3/4’’ 19-5/8’’

60°

4000

Wide-Body 4’

6000

23-1/8’’

Features •Sturdy one-piece post-painted housing providing clean, smooth, installation-friendly corners. •Side-mounted ballast for low 2-3/4" profile. •Mounting heights up to 45'. •6-lamp versions only (cross-section view). •Available in 4' lengths only. •Choice of contoured specular or flat white reflector. •Contoured specular reflector offers optimum performance and 95% reflectivity. •Choice of stem, surface or chain mounting. •Accepts emergency battery packs. •Available motion sensor allows for total lighting control, added energy savings (see page 155). Options pages 150-156 Ballast Specify voltage (120, 277, UNV, 347) and add suffix, e.g. 120P6. O5 = T8 Elect. One 4-lamp and one 2-lamp I.S. THD<20%. P6 = T5HO Elect. P.S. One 4-lamp ballast to operate outside lamps. One 2-lamp ballast to operate inside lamps. THD<10%. P7 = T5HO Elect P.S. One 3-lamp ballast to operate lamps 1, 3 and 5. One 3-lamp ballast to operate lamps 2, 4 and 6. THD<10%. Consult your Canlyte representative for other ballast options. Wireguard/Lens Variety of shielding options available (see photos opposite). Internal Fusing Suffix F. Electrical/Wiring Options Consult your Canlyte representative. Stem and Canopy Sets 4 stems required per luminaire. Order catalogue number STKF12 (12"), STKF18 (18"), STKF24 (24"), STKF36 (36"), STKF48 (48"). Chain Hanger Kit 2 kits required per luminaire. Order catalogue number EE9HC. uminaire-Mounted Motion Sensor 360° coverage. Field installed. Lu Only available on luminaires with contoured specular reflectors. Order catalogue number FH360-120 / FH360-277 / FH360-347. Remote-Mounted Motion Sensor Narrow coverage. Field installed. Order catalogue number FH110. Used with PowerPack, order catalogue number FHP20-120* (120V)/ FMP20-277 (277V)/ FHP20-347 (347V). * See factory for specifications

36’’

2 3

92 85

4 5

79 72

6 7

67 62

8 9

58 53

10

49

30°

15’’

WW: White hinged wireguard only (no lens), 9-gauge wire adding rigidity to luminaire.

VA: Pattern 12 prismatic lens made of virgin acrylic (.095" nominal). Complete with hinged white wireguard.

XX: Version without lens shielding.

104

CU 100

49-1/2’’

INDUSTRIAL

Designed for Trade (commercial spaces), Recreational and Industrial locations, TriLyte provides much needed versatility in highbay applications. Using the appropriate lamp, wattage and reflector options, this wide-body version is also suitable for lowbay lighting, particularly retail outlets and indoor sports facilities. Its low-profile housing (almost 1" shallower than most competing models) is perfect for areas that place a premium on luminaire appearance. Dual-circuit TriLyte equipped with optional motion sensor delivers added lighting control flexibility for industrial applications.

RCR 1

xx = Luminaire Length.

VB: Pattern 12 prismatic lens made of virgin acrylic (.125" nominal). Complete with hinged white wireguard.


Industrial Luminaires

Ordering Guide - T5

Application Data*

Reference Data Efficiency Spacing Ratio

90.0% 1.2

Electronic Ballast Input Watts (120V) Ballast Factor

358W 1.00

Luminaire Spacing

FC

W/Sq Ft

120' x 80' x 28' Space 240 sq ft per lum.

80

1.5

120' x 80' x 28' Space 20' on centre

50

1.9

300' x 400' x 25' Space 18' on centre

75

1.1

300' x 400' x 25' Space** 22' on centre

50

0.76

Type

Lamps Lamp/Luminaire Luminaire Catalogue qty/type Nominal Length width number

Prismatic Lens (VB) with Wireguard

6-T5HO

48"

23"

FH4C5DVB654UNVP6

White Wireguard 6-T5HO with no Lens

48"

23"

FH4C5DWW654UNVP6

Ordering Guide - T8 Type

Luminaire-Mounted Motion Sensor 360° coverage. Field installed. Catalogue Number FH360-120 / FH360-277 / FH360-347.

Remote-Mounted Motion Sensor Narrow coverage. field installed. Catalogue Number FH110. This sensor is sold in conjunction with a Power pack # FHP20-120 (120 V), FHP20-277 (277 V) or FHP20-347 (347 V), please order accordingly.

Lamps Lamp/Luminaire Luminaire Catalogue qty/type Nominal Length width number

Prismatic Lens (VB) with Wireguard

6-T8

48"

23"

FH4C5DVB632120O6

White Wireguard 6-T8 with no Lens

48"

23"

FH4C5DWW632120O6

UNV

FH4W5DWW654 Basic catalogue number: TriLyte Luminaire

P6

Voltage: 120 277 347

Ballast: See below.

Options: See below Add appropriate suffix to catalogue number

Numbering Logic

FH

4

Luminaire Type Luminaire Length FH : TriLyte 4: 4’

W Body Style W: Flat Design White Reflector C: Contoured Specular Reflector S: Flat Design Specular Reflector

5 Width 5: 23”

D Type D: Downlight

WW Lens/Shieldinng VA: Prismatic Lens VA with Wireguard VB: Prismatic Lens VB with Wireguard WW: Wireguard, White/No Lens XX: No Shielding

6 Lamp Quantity in a luminaire cross-section 6: 6 lamps

54

UNV

Lamp/Type 28: T5 28W 32: T8 32W 54: T5HO 54W

Voltage 120 277 UNV 347

P6 Options Add appropriate suffix to catalogue number see pages 150-156

Ballast O5 = One 4-lamp and one 2-lamp I.S. THD<20% P6 = T5HO Elect. P.S. One 4-lamp/outside lamps. One 2-lamp/inside lamps. THD<10% P7 = T5HO Elect P.S. One 3-lamp ballast for lamps 1, 3 and 5, One 3-lamp ballast for lamps 2, 4 and 6, THD<10%

Acronyms Used CU: Coefficients of Utilization FC: Footcandles IS: Instant Start LLF: Light Loss Factor PS: Program Start RCR: Room Cavity Ratio THD: Total Harmonic Distortion

* Average Footcandles Maintained. Total LLF = 0.84. Reflectance: 80% Ceiling, 50% Wall, 20% Floor. 54W T5HO lamp rated at 4400 lumens at 25oC.

105


Industrial Luminaires

Industrial 4’, 8’ (EE, FF) Open Industrial Luminaires EE248-120SO (Data)

0

RCR

500 60°

1000

1510

INDUSTRIAL

Features •Reflector is embossed for rigidity. •Reflector sides are turned up for rigidity. •Solid top reflector, EE series. •10% aperture reflector, FF series. •Fully enclosed wiring.

70 62

5 6

53 48

7 8

43 38

9 10

34 31

30°

4-5/8" (117.4 mm) 6-1/4" (158.7 mm)

0

500

13" (330.2 mm)

60°

4-5/8" (117.4 mm) 1000

6-1/4" (158.7 mm) 13" (330.2 mm)

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 91 79 70 62 55 49 44 39 35 32

1554 0°

106

3 4

TU248-120SO (Data)

Premium Open Industrial

• T12 options are limited due to new regulations. Please consult factory for their availability. • Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forth by National Resources Canada.

92 80

pages 150-156 Options Ballast Specify voltage (120, 277, 347) and add suffix (e.g. EE248-120SO) E.S. Magnetic Electronic One-3 Lamp Electronic One-4 Lamp Electronic RS T12: LE SL T12: LE† HO T12: LE† T8: OC T8: SO 3 LPB T8: O3 4 LPB T8: O4 LPB : Number of lamps per ballast. † Available only for 8’. For T12 HO 4’ leave blank. Cold Weather Ballasts HO standard with -17°F (-27°C) ballasts. For RS type luminaires add suffix SC (T8 electronic) CW (T12 magnetic), to Catalogue Number. Slide Grip Hanger (HO, only) Accepts 1/2" thread stems or rods. Slides into luminaire chassis grooves. Order catalogue number EE9H3. Chain Hanger Kit Order catalogue number EE9HC. 4' Wire Guard Order two per 8' luminaire. Order catalogue number EE9G4. Reflector Row Aligner For continuous row installations. Order catalogue number EE9RA. Hard Surface Mounting or Twist Tee For 4-1/2" deep channel, catalogue number EE9H1.

Turret Open T8 / T5 Industrial 4’, 8’ (TU)

Features • Rugged telescoping turret lampholders. • Optimum 6" lamp spacing (2 lamp). • Reflector is embossed for rigidity. • Reflector sides are turned up for rigidity and safe handling. • 15% aperture reflector, standard. • Solid top reflector, optional. • Reflector secured to housing with easy to use thumb screws. • 4-5/8" wide channel type housing. • Fully enclosed wiring. • Reflector row aligner included. • Reflector post painted with 89% reflectance white polyester paint. • Optional silver reflector. • Optional louver or lens shielding. • Available in T5 and T8 lamp options.

C. U.

1 2

30°

pages 150-156 Options Ballast Specify voltage (120, 277 347) and add suffix, (e.g. TU248-120SO) Magnetic Electronic One-3 Lamp Electronic One-4 Lamp Electronic RS T12: LE T5/T5HO: PG T5HO: PU T5HO: PV SL T12: LE† HO T12: LE† T8: OC T8: SO 3 LPB T8: O3 4 LPB T8: O4 LPB : Number of lamps per ballast. † Available only for 8’. For T12 HO 4’ leave blank. Cold Weather Ballasts HO standard with -17°F (-27°C) ballasts. For RS type luminaires add suffix SC (T8 electronic) CW (T12 magnetic), to catalogue number. Housing Row Couplers For continuous row mounting (stem/chain). One per joint required. Order catalogue number TU9PLC. Slide-Grip Hangers Accepts 1/2” thread stems or rods. Slides into luminaire chassis grooves. Order catalogue number EE9H3. Chain Hanger Kit Order catalogue number EE9HC. 4’ Wire Guard Order catalogue number TU9G4. Reflector: Use suffix SD for solid reflector. Silver Reflector consult factory. Shielding: Lens TU9LN4 Louver: TU9LV4 End Plate Set: Order 1 set for continuous row mount or in conjuction with shielding applications TU9END.


Industrial Luminaires

Application Data*

Reference Data Efficiency Spacing Ratio

88.4% 1.5

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing

W/Sq Ft

Type

Lum. lgth. nominal

Lamps in width

Lamp type

Lamp length

78

1.2

Solid Top reflector

100

1.3

86

1.2

48" 48" 96" 96" 48" 96" 48" 96" 96"

1 2 1 2 3 3 2 1 2

1 x T12/T8 2 x T12/T8 2 x T12/T8 4 x T12/T8 3 x T12/T8 6 x T12/T8 2 x HO 1 x SL 2 x SL

48" 48" 96" 96" 48" 96" 48" 96" 96"

84

1.4

10% Uplight Reflector

96" 96" 48" 48" 96" 96" 48" 96" 48" 96" 96" 96" 96"

1 2 1 2 1 2 3 3 2 1 2 1 2

1 x HO 2 x HO 1 x T12/T8 2 x T12/T8 2 x T12/T8 4 x T12/T8 3 x T12/T8 6 x T12/T8 2 x HO 1 x SL 2 x SL 1 x HO 2 x HO

96" 96" 48" 48" 96" 96" 48" 96" 48" 96" 96" 96" 96"

50' x 70' x 12' Space 12' on centre

62.0W .88

Ordering Guide FC

50' x 70' x 8.5' Space 10' on centre 50' x 70' x 8.5' Space 12' on centre 30' x 30' x 8.5' Space 12' on centre

FF296H Basic catalogue number : Open Industrial

Application Data*

Reference Data Efficiency Spacing Ratio

89.2% 1.3

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing

62.0W .88

Ordering Guide Type

Lum. lgth. nominal

Lamps in width

Lamp type

Lamp length

60

0.9

15% Uplight Flat Reflector

76

1.2

97

1.3

83

1.4

48" 96" 48" 96" 48" 96" 48" 48" 96" 48" 48" 48" 48"

2 2 2 2 3 3 4 2 2 3 3 4 4

2x T5 4x T5 2X T12/T8 4X T12/T8 3X T12/T8 6X T12/T8 4X T12/T8 2X T5HO 4x T5HO 2x T5 2X T5HO 2x T5 2X T5HO

46" 46" 48" 48" 48" 48" 48" 46" 46" 46" 46" 46" 46"

Catalog number TU228 TU228T TU248 TU248T TU348 TU348T TU448 TU254 TU254T TU328 TU354 TU428 TU454

120

LE

Voltage : 120 277 347

Ballast : For options consult page 106

Options : For options consult page 106

50' x 70' x 8.5' Space 10' on centre 30' x 30' x 8.5' Space 12' on centre

TU296H Basic catalogue number : Premium Turret Industrial

Heavy Duty Slide-Grip Hanger EE9H3.

Options : For options consult page 106

W/Sq Ft

50' x 70' x 12' Space 12' on centre

LE Ballast : For options consult page 106

FC

50' x 70' x 12' Space 16' on centre

120 Voltage : 120 277 347

Catalogue number EE148 EE248 EE148T EE248T EE348 EE348T EE248H EE196S EE296S FF196H FF296H FF148 FF248 FF148T FF248T FF348 FF348T FF248H FF196S FF296S FF196H FF296H

Chain Hanger Kit EE9HC. Two 24� heavy duty link chain.

*Average Footcandles Maintained. Total LLF=BF (1.0) x .85 = .85 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

107


Special Applications Luminaires

Sealatron 4’, 8’ (VT, VTN) Damp / Wet Locations Enclosed VT

VT248-120SO (Data) 4 1/2" (114mm) 102" (2591mm)

7 5/8" (194mm)

90°

0

500 60°

5 5/8"" (143mm) SL 97 13/16" (2484mm)

7 5/8" (194mm)

1000

1517 0°

49" (1321mm)

SPECIAL APPLICATIONS

Features •CSA listed for damp/wet locations. •One-piece fiberglass reinforced polyester housing. •Smooth virgin acrylic lens. •Crepe pattern inner surface lens. •Bonded closed-cell neoprene gasket. •Molded cam-action tension latches. •RS version is 4-1/2" deep. SL and HO are 5-5/8" deep. •Optional polycarbonate lens. •Optional tamper proof latch. •Optional inside silver reflector. •Up to 86% efficient with silver reflector.

C. U.

1 2

64 55

3 4

49 43

5 6

38 34

7 8

30 27

9 10

24 22

Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic T8: OC 1 or 2 LPB T8: SO † T12: LE 4 LPB T8: O4 LPB : Number of lamps per ballast. † Not available for T12 HO 4’, leave blank for a standard ballast. Cold Weather Ballasts HO standard with -17°F (-27°C) ballasts. For RS type luminaires add suffix SC (T8 electronic) CW (T12 magnetic), to catalogue number for 0°F (-17°C) ballasts. Water Tight Kits Hub kit for top or end conduit entry. Order suffix: WHP0001. Electrical/Wiring Options For special wiring, fusing: consult factory. Lens: Smooth virgin acrylic with crepe pattern inner surface lens is standard for opal lens add (SW), for high impact lens (DR). For polycarbonate lens use suffix VX. Latch: For tamper proof latch use suffix 9. Silver Reflector Use Suffix: X. • T12 options are limited due to new regulations. Please consult factory for their availability. • Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forth by National Resources Canada.

Sealatron Plus 2’, 4’, 8’ (VTS)

VTS

VTS248-120SO (Data)

Damp / Wet Locations Enclosed Class III Features • CSA listed for damp/wet locations. • CSA listed for Class III, Hazardous location (see page 112). • One-piece fiberglass reinforced polyester housing. • Smooth virgin acrylic lens. • Crepe pattern inner surface lens. • Bonded closed-cell neoprene gasket. • Molded cam-action tension latches. • Optional polycarbonate lens. • Optional tamper proof latch. • Optional inside silver reflector. • Up to 86% efficient with silver reflector. • Water tight kits included (one kit). • No holes are required for mounting, protecting the integrity of the housing. • Galvanized mounting brackets included (2 per luminaire). • Brass mounting studs. • N/A in HO. • IP65 rated.

108

30°

RCR

5" (127mm) 7" (178mm)

0

90°

500

97 13/16" (2484mm)

60°

1000

47 13/16" (1265mm) 1517 0°

30°

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 64 55 49 43 38 34 30 27 24 22

Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic T8: OC 1 or 2 LPB T8: SO T12: LE 4 LPB T8: O4 40W TT5: SB LPB : Number of lamps per ballast. Cold Weather Ballasts add suffix SC (T8 electronic) CW (T12 magnetic), to catalogue number. Water Tight Kit Hub kit for top or end conduit entry. Order suffix: WHP0001. Electrical/Wiring Options For special wiring, fusing: consult factory. Lens: Smooth virgin acrylic with crepe pattern inner surface lens is standard. For polycarbonate lens use suffix VX. Latch: For tamper proof latch use suffix 9. Silver Reflector Use Suffix: X. • T12 options are limited due to new regulations. Please consult factory for their availability. • Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forth by National Resources Canada.


Special Purpose Luminaires

Reference Data Efficiency Spacing Ratio

Application Data* 64.6% 1.5

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing

W/Sq Ft

58

1.9

68

1.4

50' x 70' x 12' Space 12' on centre

62.0W .88

FC

30' x 30' x 8.5' Space 10' on centre

Ordering Guide Type Luminaire length Damp and Wet Locations

12' x 16' x 8.5' Space 8' on centre

67

Lamps in width

Lamp type

Lamp length

49 13/16" 97 13/16"

1 1 (2 Lamps in Tandem)

T12/T8 T12/T8

48" 48"

Catalogue number VTN4132ST VTN8132ST

49 13/16" 97 13/16"

2 2 (4 Lamps in Tandem)

T12/T8 T12/T8

48" 48"

VTN4232ST VTN8232ST

97 13/16" 52" 102" 52" 102"

2 1 1 2 2

SL HO HO HO HO

96" 48" 96" 48" 96"

VTN8275ST VT148H VT196H VT248H VT296H

1.9

VT248 Basic catalogue number :

Precision molded pre-formed knockouts for stem, chain or surface mounting.

Reference Data Efficiency Spacing Ratio

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing

FC

W/Sq Ft

58

1.9

68

1.4

67

1.9

50' x 70' x 12' Space 12' on centre

62.0W .88

SO

Voltage : 120 277 347

Ballast : See page 108

Smooth virgin acrylic lens opens easily and hinges from either side for easy maintenance.

Application Data* 64.6% 1.5

120

30' x 30' x 8.5' Space 10' on centre

Ordering Guide Type Luminaire length Damp and Wet Locations Class III

Options : See page 108 Add appropriate suffix to catalogue number

Lamps in width

Lamp type

Lamp length

25-13/16" 25-13/16" 49-13/16" 97-13/16"

1 2 1 1 (2 Lamps in Tandem)

TT5 T12/T8 T12/T8 T12/T8

24" 24" 48" 48"

Catalogue number VTS1FT VTS224 VTS148 VTS148T

49-13/16" 97-13/16"

2 2 (4 Lamps in Tandem)

T12/T8 T12/T8

48" 48"

VTS248 VTS248T

12' x 16' x 8.5' Space 8' on centre

VTS248T Basic catalogue number :

*Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

120 Voltage :

04 Ballast :

Options :

109


Special Applications Luminaires

Cleanlite 4’ (SW) Damp / Wet Locations Enclosed Surface Luminaire SW4C232120SO (Data) 2-13/16" (71.4mm)

6-1/16" (26.9mm)

0

90°

400

8-5/32" (207.1mm)

60°

2-13/16" (71.4mm)

6-1/16" (26.9mm)

800

30°

8-5/32" (207.1mm)

SPECIAL APPLICATIONS

Features •CSA certified for damp or wet locations. •20 gauge steel chassis. •Smooth one-piece water-clear lens. •Lock-tight cam-action latches. •4' one-piece bodies. •Convenient 8" width. •Optional water tight hubs for electrical feed (SW). •Foam gasketing at all lens seal points.

RCR

79 67

3 4

59 52

5 6

45 40

7 8

36 32

9 10

29 26

Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic T8: OC 1 or 2 LPB T8: SO T12: LE† 4 LPB T8: O4 LPB : Number of lamps per ballast. † Not available for T12 HO 4’, leave blank for a standard ballast. Tamper-Proof Latches Zinc cam-latches with spanner head screws. Add Suffix 9 to catalogue number. Water Tight Kits For SW type luminaires only. Hub kit for top or end conduit entry. One kit supplied with luminaires. Order catalogue number: GWHB001. Lens Smooth one-piece water-clear lens is standard. For high impact acrylic lens, suffix (DR). For opal lens, add (SW). For lexan (SR). Cold Weather Ballasts HO standard with -17°F (-27°C) ballasts. For RS type luminaires add suffix SR (T8 electronic) CW (T12 magnetic), to catalogue number. • T12 options are limited due to new regulations. Please consult factory for their availability. • Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forth by National Resources Canada.

General Wet Location 1’x 4’, 2’x 2’, 2’x 4’ (RVS) Recessed Gasketed Luminaire

RVSIFFSVB232120SO (Data) 0

500 60° 1000

1704 0°

1’ x 4’, 2’ x 4’ recessed fluorescent - static with gasket 1, 2, 3 and 4 T8 lamps Features •61.6% efficient. •Neoprene gasket all around. •Full flush steel hinged lens frame. •Lens frame held with screws. •Twin knockout access plate. •Optional tamper-proof screws (consult Factory). •Snap-in ballast cover. •CSA certified for wet location.

30°

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 66 59 53 48 43 39 35 32 29 26

Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming T8: OC 1 or 2 LPB T8: SO T8: PS 3 LPB T8: O3 (not avail. in 347V) 4 LPB T8: O4 For T12 lamp see page 151. LPB : Number of lamps per ballast. Special Lenses VB prismatic lens standard. (Prismatic .125” nominal, pattern 12). Replace VB by VX for polycarbonate .125” nominal, pattern 12. Example: RVS1FFSVX232120SO. Electrical/Wiring Options Consult factory. Fusing Suffix: F. Radio Interference Filter 120 or 347 volt, 50 or 60 Hz. Suffix R. • T12 options are limited due to new regulations. Please consult factory for their availability. • Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forth by National Resources Canada.

110

C. U.

1 2


Special Applications Luminaires

Application Data*

Reference Data Efficiency Spacing Ratio

79.3% 1.6

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing

W/Sq Ft

65

1.2

76

1.4

73

1.9

Ordering Guide Type Luminaire length

50' x 70' x 8.5' Space 12' on centre

62.0W .88

FC

Wet Locations

30' x 30' x 8.5' Space 10' on centre

Lamps in width

Lamp type

Lamp length

Catalogue number

50-5/16" 50-5/16"

1 2

T8 T8

48" 48"

50-5/16"

2

HO

48"

SW4C132 SW4C232 SW4C248HO

12' x 16' x 8.5' Space 8' on centre

Water tight hub kit: GWHB001

61.6% 1.2

Electronic Ballast Input Watts (120V) Ballast Factor

4

Luminaire Type SW

Luminaire Length 4: 4’

C

Application Data*

Reference Data Efficiency Spacing Ratio

SW

62.0W .88

Luminaire Spacing

FC

W/Sq Ft

8' x 8' (64 sq ft/luminaire)

51

.9

8' x 10' (80 sq ft/luminaire)

40

.7

46

1.1

50' x 70' x 8.5' Space

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

2

32

Number of lamp in a luminaire cross-section 1 2

120

Lamp Type 32: T8 4’ 34: T12 4’ 48 HO: T8 or T12 HO 4’

Voltage 120 277 347

Ordering Guide Type Luminaire Lamps size qty /type Clean Room Recessed Static

1x4 1x4 2x2 2x4 2x4 2x4

RVS2GFSVB432 Basic catalogue number :

1-T8 2-T8 2-T8U6 2-T8 3-T8 4-T8

SO Ballast See page 110

Flanged for dry or plaster RVS1FFSVB132 RVS1FFSVB232 RVS2FFSVB26U RVS2FFSVB232 RVS2FFSVB332 RVS2FFSVB432

120 Voltage :

*Average Footcandles Maintained. Total LLF=BF (1.0) x .85 = .85 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

Options See page 110

Exposed T-Grid RVS1GFSVB132 RVS1GFSVB232 RVS2GFSVB26U RVS2GFSVB232 RVS2GFSVB332 RVS2GFSVB432

04 Ballast :

Options :

111


Special Applications Luminaires

Hazardline 4’ (HSC) Fiberglass reinforced polyester composite body • Vapor / Dust / Wet Locations Enclosed HSCXT232120SO (Data) 5-9/32" (134 mm) 0

8-9/32" (210.3 mm)

9-23/32" (246.8 mm)

RCR 500

9-23/32" (246.8 mm)

60°

5-9/32" (134 mm) 1000

8-9/32" (210.3 mm)

SPECIAL APPLICATIONS

This luminaire is suitable for indoor and outdoor applications in three areas. Class I Div. 2 locations are those in which flammable gases, vapors or liquids are handled in closed containers from which any escape of hazardous materials are accidental. Class II locations are hazardous because of the presence of combustible dust. Class III locations are hazardous because of the presence of easily ignitable fibers or flyings. In addition, Hazardline has a wet location rating for use indoors. Features •cUL-Listed Class I, Division 2, Groups A, B, C, and D locations. •cUL-Listed Class II, Divisions 1 and 2, Class III, Divisions 1 and 2 locations. •cUL-Listed for wet locations. •Non-corrosive fiberglass reinforced polyester composite body suitable (T8 or T12RS) for 104°F (40°C) ambient temperature. •Meets UL 844 static discharge requirements. •Meets UL 746C impact Test requirements. •Meets UL 94-5VA fire rating. •Baked white acrylic enamel, 16 gauge stainless steel door frame with 3/16" tempered glass lens. •Rugged stainless steel toggle clamps to secure lens door frame. •1/2" NPT taper-threaded cast aluminum suspension hubs (4 per luminaire). •One piece all-around gasketing. •Quick-change power-channel ballast design. •Marine grade also available.

Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. HSCXT248HO277SS. Magnetic Electronic One-3 Lamp Electronic T12: LE HO T12: Blank T8: OC T8: SO T8: O3 Electrical/Wiring Options For special wiring, fusing, and emergency pack, consult factory. • T12 options are limited due to new regulations. Please consult factory for their availability. • Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forth by National Resources Canada.

112

9-23/32" (246.8 mm) 9-23/32" (246.8 mm)

1511 0°

C. U.

1 2

77 67

3 4

59 53

5 6

47 42

7 8

38 35

9 10

32 30

30°

Hazardous Location Definition The following hazardous location definitions are excerpted from Article 500 of the 1990 National Electrical Code. Class I, Division 2 Locations A Class I, Division 2 location is a location (1) in which volatile flammable liquids or flammable gases are handled, processed, or used, but in which the liquids, vapors, or gases will normally be confined within closed containers or closed systems from which they can escape only in case of accidental rupture or breakdown of such containers or systems, or in case of abnormal operation of equipment. Class II Locations Class II locations are those that are hazardous because of the presence of combustible dust. (a) Class II, Division 1. A Class II, Division 1 location is a location: (1) which combustible dust is in the air under normal operating conditions, in quantities sufficient to produce explosive or ignitible mixtures; or (2) where mechanical failure or abnormal operation of machinery or equipment might cause such explosive or ignitible mixtures to be produced, and might also provide a source of ignition through simultaneous failure of electric equipment, operation of protection devices, or from other causes; or (3) in which combustible dusts of an electrically conductive nature may be present in hazardous quantities. (b) Class II, Division 2 A Class II, Division 2 location is a location where combustible dust is not normally in the air in quantities sufficient to produce explosive or ignitible mixtures, and dust accumulations are normally insufficient to interfere with the normal operation of electrical equipment or other apparatus, but combustible dust may be in suspension in the air as a result of infrequent malfunctioning of handling or processing equipment and where combustible dust accumulations on, in, or in the vicinity of the electrical equipment may be sufficient to interfere with the safe dissipation of heat from electrical equipment or may be ignitible by abnormal operation or failure of electrical equipment. Class III Locations Class III locations are those that are hazardous because of the presence of easily ignitible fibers or flyings, but in which such fibers or flyings are not likely to be in suspension in the air in quantities sufficient to produce ignitible mixtures. (a) Class III, Division 1. A Class III, Division 1 location is a location in which easily ignitible fibers or materials producing combustible flyings are handled, manufactured, or used. (b) Class III, Division 2. A Class III, Division 2 location is a location in which easily ignitible fibers are stored or handled.


Special Application Luminaires

Application Data*

Reference Data Efficiency Spacing Ratio

Luminaire Spacing

72.8% 1.3

W/Sq Ft

51

0.9

54

1.2

50' x 70' x 12' Space

Electronic Ballast Input Watts (120V) Ballast Factor

FC

8' x 8' (64 sq ft/luminaire) 62.0W .88

Enclosed Industrial Fluorescent

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

HS

CXT

2

32

120

Luminaire Type HS

Division CXT

Number of lamps 2 3

Lamp Type 32: T8 4’ 48 HO: T8 or T12 HO 34: T12 4’

Voltage 120 277 347

Ordering Guide Type Class/ division Vapor-tight Class I Division 2

Luminaire length

Lamp type

Lamps in width

53"

2 x T8 2 2 x HO* 2 3 xT8 3

Catalogue number HSCXT232 HSCXT248HO HSCXT332

*800 MA HO luminaires are standard with -20°F (-29°C) ballasts.

SO Ballast See page 112

Options See page 112

THERMAL PERFORMANCE OF HSCXT LUMINAIRES* Lamps Quantity Type 2 T12/T8 3 T12/T8 2 HO

Ambient “T” Luminaire Temp. °C Numbers Temperature* 40 T-4A 120°C (248°F) 40 T-4A 120°C (248°F) 25 T-3C 160°C (320°F)

*Maximum temperature on any part of the luminaire.

Features

Hi-Temp Power Channel

Heavy-Duty Hinged Stainless Steel Door

Top/End Suspension Hubs

Options

45° Adjustable Quadrant Brackets Suffix: NKH45 *Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor. RE835 lamp rated at 3000 lumens.

113


Special Application Luminaires

Video Teleconference 2’ x 4’ (VTS) Recessed Video Teleconferencing Parabolic VTS2GPK332120O3

90°

6" (152mm) 1000 60°

24" (610mm) 2000

3000 0°

6" (152mm)

The VTS series combines the sharp cut-off of a VDT parabolic with the Features wide distribution and vertical illumination of a lensis troffer in a unique • Excellent for locations where vandal resistance required. design that provides ideal illumination for video conferencing areas. • Prismatic lens (VL) is 3/16" thick pattern 12, minimum impact

SPECIAL APPLICATIONS 114

strength, 130 foot pounds. Features • Full perimeter gasketing (closed cell between doorof • Provides soft vertical illumination forNeoprene) comfortable televising frame and lens. participants. • Shields Tamper resistant holtfrom head screws secure to housing. • the camera light sources and lens eliminates glare on the • projection 5" deep body, 2x2 and 2x4. screen. • Integrated 74.4% efficient (T8),parabolic 2x4 4 lamp. • specular blades and prismatic acrylic lens • assembly Hemmed over side rails for maximum safety. for directional brightness control. • 86 Fixture ends turned-in for safe • minimum VCP in rooms withhandling. less than 10' ceiling (3 lamp T8). • Spring-loaded Built-in earthquake clips (patent no. 5,072,344), on 2x2 and 2x4. • latches. • Concealed Spring loaded • “T”rooster hinges.head latches. • Louver/lens 18 gauge steel hinges.with positive light stop. • assembly • Four 69.3% efficient (T8), 2-6"U. • earthquake clips2x2 standard. • 62.2% efficient (T8), 1x4 2 lamp. Options page 150-156 Options Page 520 Ballast Specify voltage (120 or 277) and type and add as suffix, e.g. Ballast Specify voltage (120 or 277) and type and add as suffix, 120SO e.g. 120S0. BALLAST CODE Electrical/Wiring Options wiring, fusing, electronic TYPE <20THD For special <10THD dimming ballasts, consult factory. Electronic T8 SO* HI* Seismic Hold-Down Clip G, Suffix: 2HD. 1-3 lamp T8 O3* For 1'x4' typeH3* Factory 1-4 lampinstalled. T8 O4* H4* LOL Dimming PS troffers, order plaster frames separately. Plaster Frame For F type Catalog Number: *Instant Start PF24 for 2'x4' troffer; PF22 for 2'x2' troffer, PF14 for 1'x4' troffer. Electrical/Wiring Options For special wiring, fusing, electronic Fusing Internal fusing. SUFFIX: GLR Internal slow-blow dimming ballast,fast-blowing consult factory. fusing. SUFFIX: GMF Note: for drywall ceiling, use ”G” type fixtures with DRYWALL BALLAST KIT, FK92X4. CODE TYPE Internal fast-blow fusing. <20THD Fusing Suffix: F. <10THD Electronic T8 SO* HI* 1-3 Lamp T8 O3* H3* 1-4 Lamp T8 O4* H4* 1-3 Lamp TT5 40 Watt X3* I3* 1&2 Lamp TT5 40 Watt SB* IB* *Instant Start Lens For optional 9/64" thick (VK) pattern 12, minimum impact strength, 80 foot pounds, substitute VL with VK in Catalog No. i.e:GVS2GFSVK432.

30°

2" x 2-1/2" access plate with two K.O.s (7/8" dia.)

RCR

39-1/4" (997mm) 47-31/32" (1218mm)

C. U.

1 2

67 63

3 4

58 55

5 6 7 8

51 48 45 42

9 10

39 37


Special Application Luminaires

Application Data*

Reference Data Efficiency Spacing Ratio

59.7% 1.1

Electronic Ballast Input Watts (120V) Ballast Factor

85.0W 0.88

Luminaire Spacing

FC

W/Sq Ft

8' x 8' (64 sq ft/luminaire)

57.9

1.25

8' x 10' (80 sq ft/luminaire)

57.9

1.25

46.8

1.11

20' x 30' x 8.5' Space

Ordering Guide Type Size Static Static Static

2X4 2X4 2X4

Lamps qty/type

Grid

Slot Grid

2-T8 3-T8 4-T8

VTS2GPK232 VTS2GPK332 VTS2GPK432

VTS2TPK232 VTS2TPK332 VTS2TPK432

15' x 20' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

VTS2GPK332 Basic catalogue number : VideoTeleconference Recessed

120 Voltage : 120 277

03 Ballast : See page 114

Options : See page 114

6' Min.

Lamp Direction

End of Fixture

Viewing Screen

TELECONFERENCING ORIENTATION

Teleconference Lighting Recommendations 1. I.E.S. recommends 50 maintained footcandles for teleconferencing. 2. 3000K lamps with C.R.I. of 82 suggested for better skin tone. 3. Teleconferencing luminaires are to be mounted in the ceiling with the lamps perpendicular to the wall that the viewing screen is on. 4. The end of the first fixture must be a minimum of 6 feet from the viewing screen (see diagram). 5. Side and back walls should be illuminated to reduce contrast vs. other vertical surfaces. Use wall lighting luminaires where necessary. 5:1 maximum luminance ratio suggested. 6. It is suggested that Dimming Ballast be used to adjust for reflection surfaces in the zoom.

*Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor. RE835 lamp rated at 3000 lumens.

115


Special Application Luminaires

Video Teleconference 2’ x 2’ (VTS) Recessed Video Teleconferencing Parabolic VTS2GPK3FT120X3

90°

6" (152mm) 1150 60°

24" (610mm)

2300 3450 0°

SPECIAL APPLICATIONS 116

The VTS series combines the sharp cut-off of a VDT parabolic with the Features wide distribution and • Excellent for locations where vandal resistance is required. vertical illumination of is a lens in a unique design that provides • Prismatic lens (VL) 3/16"troffer thick pattern 12, minimum impact ideal illumination for video conferencing areas. strength, 130 foot pounds. • Full perimeter gasketing (closed cell Neoprene) between door Features frame and lens. • Provides soft vertical illumination for comfortable televising • Tamper resistant holt head screws secure lens to housing. of participants. • 5" deep body, 2x2 and 2x4. • Shields the camera from light sources and eliminates glare • 74.4% efficient (T8), 2x4 4 lamp. on the projection screen. • Hemmed over side rails for maximum safety. • Integrated specular parabolic blades and • Fixture ends turned-in for safe handling. prismatic acrylic lens assembly for directional • Built-in earthquake clips (patent no. 5,072,344), on 2x2 and 2x4. brightness control. • Spring loaded rooster head latches. • 77 minimum VCP in rooms with less than 10' • 18 gauge steel hinges. ceiling (3 lamp T5). • 69.3% efficient (T8), 2x2 2-6"U. • Spring-loaded latches. • 62.2% efficient (T8), 1x4 2 lamp. • Concealed “T” hinges. Options Page 520 • Louver/lens assembly with positive light stop. • Four earthquake clips(120 standard. Ballast Specify voltage or 277) and type and add as suffix, e.g. 120S0. Options page 150-156 Electrical/Wiring Options special fusing, electronic Ballast Specify voltage (120 For or 277) andwiring, type and add as suffix, dimming ballasts, consult factory. e.g. 120SO. Seismic Hold-Down Clip For 1'x4' type G, Suffix: 2HD. BALLAST CODE Factory installed. TYPE <20THD Plaster Frame For F type troffers, order plaster<10THD frames separately. Electronic T8 HI* troffer, PF14 Catalog Number: PF24 for 2'x4'SO* troffer; PF22 for 2'x2' Electronic T8 SO* HI* for 1'x4' troffer. 1-3 lampInternal T8 O3* SUFFIX: GLRH3* Fusing fast-blowing fusing. Internal slow-blow Electronic TT5 GMF SB* IB* fusing. SUFFIX: 1-3 LAMP TT5-40 Watt X3* I3* BALLAST CODE LOL Dimming TT5 PB TYPE <20THD <10THD *Instant Start Electronic T8 SO* HI* Electrical/Wiring Options ForO3* special wiring, fusing, 1-3 Lamp T8 H3* electronic dimming ballast, 1-4 Lamp T8 consult factory. O4* H4* Note: for drywall ceiling, use “G” 1-3 Lamp TT5 40 Watt X3*type fixtures with I3* DRYWALL KIT,40FK92X2. 1&2 Lamp TT5 Watt SB* IB* *InstantInternal Start fast-blow fusing. Suffix: F. Fusing Lens For optional 9/64" thick (VK) pattern 12, minimum impact strength, 80 foot pounds, substitute VL with VK in Catalog No. i.e:GVS2GFSVK432.

30°

RCR

23-7/8" (606mm)

15-11/16" (398mm) 5" (127mm) 2"x2-1/2" access plate with two K.O.s (7/8" dia.)

C. U.

1 2

62 58

3 4

54 51

5 6

48 45

7 8

42 39

9 10

37 35


Special Application Luminaires

Application Data*

Reference Data Efficiency Spacing Ratio

55.1% 1.2

Electronic Ballast Input Watts (120V) Ballast Factor

103.0W 0.88

Luminaire Spacing

FC

W/Sq Ft

8' x 8' (64 sq ft/luminaire)

59.4

1.54

8' x 10' (80 sq ft/luminaire)

59.4

1.54

48.2

1.37

Ordering Guide Type Size

20' x 30' x 8.5' Space

Static Static Static Static

2X2 2X2 2X2 2X2

Lamps qty/type

Grid

Slot Grid

2-T8 6”U 2-TT5 3-T8 1.6U 3-TT5

VTS2GPK26U VTS2GPK2FT VTSGPK32U VTSGPK3FT

VTS2TPK26U VTS2TPK2FT VTSTPK32U VTSTPK3FT

15' x 20' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

VTS2GPK3FT Basic catalogue number : VideoTeleconference Recessed

120 Voltage : 120 277

X3 Ballast : See page 116

Options : See page 116

6' Min.

Lamp Direction End of Fixture

Viewing Screen

TELECONFERENCING ORIENTATION

Teleconference Lighting Recommendations 1. I.E.S. recommends 50 maintained footcandles for teleconferencing. 2. 3000K lamps with C.R.I. of 82 suggested for better skin tone. 3. Teleconferencing luminaires are to be mounted in the ceiling with the lamps perpendicular to the wall that the viewing screen is on. 4. The end of the first fixture must be a minimum of 6 feet from the viewing screen (see diagram). 5. Side and back walls should be illuminated to reduce contrast vs. other vertical surfaces. Use wall lighting luminaires where necessary. 5:1 maximum luminance ratio suggested. 6. It is suggested that Dimming Ballast be used to adjust for reflection surfaces in the zoom.

* Pieds-bougies moyens maintenus. LLF Total = .75 Réflectivité : Plafond :80% mur : 50% plancher : 20%. Lampe de type RE835 évaluée à 3000 lumens.

117


Special Application Luminaires

Cleanguard Class 1,000 - 2’x 2’, 2’x 4’ (CXSW) Recessed Class 1,000 Clean Room / Wet Location Enclosed CXS2WFAVI26U120SO

5" (127mm) 24" (610mm)

90° 500 60° 1000

1500

SPECIAL APPLICATIONS

Features • Meets Excellent requirements for locationsforwhere Federal vandal Standard resistance 209E Class is required. 1,000/10,000 • & Prismatic 100,000lens Clean (VL) Room is 3/16" tested thick by pattern Independent 12, minimum Lab. impact • UL strength, and ULc 130Listed foot pounds. for wet or damp locations for covered ceiling use. • Fits Full perimeter 15/16" to 1-1/2" gasketing wide(closed face grid cellceiling Neoprene) systems. between Contractor door frame and lens. responsible for sealing fixture to ceiling. • Full Tamper perimeter resistant gasketing holt head (closed screws cellsecure Neoprene) lens to between housing.door • frame 5" deepand body, lens,2x2 closed and 2x4. cell ethafoam gasketing between housing • and 74.4% door efficient frame. (T8), 2x4 4 lamp. • Ends Hemmed sealed overtoside body.rails for maximum safety. • .125 Fixture pattern ends 12 turned-in lens installed for safesmooth handling. side down. • Door Built-in frame earthquake is post painted, clips (patent bakedno.acrylic 5,072,344), enamel. on 2x2 and 2x4. • Hemmed Spring loaded over rooster side rails head for maximum latches. safety. • Spring 18 gauge loaded steelrooster hinges.head latches. • 18 69.3% gauge efficient steel hinges. (T8), 2x2 2-6"U. • Flat 62.2% extruded efficient aluminum (T8), 1x4door. 2 lamp. Options Page 520 page 150-156 Ballast Specify voltage (120 or 277) and type and add as suffix, e.g. 120SO. 120S0. Electrical/Wiring Options CODE For special wiring, fusing, electronic BALLAST dimming ballasts, consult factory. TYPE <20THD <10THD Seismic Hold-Down Clip ForSO* 1'x4' type G, Suffix: Electronic T8 HI*2HD. Factory 1-3 Lampinstalled. T8 O3* H3* Plaster 1-4 LampFrame T8 For F type troffers, O4*order plaster frames H4* separately. Catalog Number: PF24 for 2'x4'SB* troffer; PF22 for 2'x2' Electronic TT5 (40Watt) IB* troffer, PF14 for 1-3 1'x4' Lamptroffer. TT5 (40Watt) X3* I3* *Fusing InstantInternal Start fast-blowing fusing. SUFFIX: GLR Internal slow-blow fusing. SUFFIX: GMFOptions For special wiring, fusing, electronic Electrical/Wiring dimming BALLASTballasts, consult factory. CODE TYPE <20THD <10THD Fusing Internal fast-blowing fusing. SUFFIX:F Electronic T8 SO* HI* 1-3 Lamp T8 O3* H3* 1-4 Lamp T8 O4* H4* 1-3 Lamp TT5 40 Watt X3* I3* 1&2 Lamp TT5 40 Watt SB* IB* *Instant Start Lens For optional 9/64" thick (VK) pattern 12, minimum impact strength, 80 foot pounds, substitute VL with VK in Catalog No. i.e:GVS2GFSVK432.

118

30° 0°

RCR

C. U.

1 2

69 63

3 4

57 53

5 6

48 45

7 8

42 39

9 10

35 34

CXS2WFAVI33212003

90°

5" (127mm) 750

60°

24" (610mm) 1500

2250

30° 0°

RCR 1 2 3 4 5 6 7

C. U. 74 68 62 56 52 48 45

8 9

41 39

10

36


Special Application Luminaires

Application Data*

Reference Data Efficiency Spacing Ratio

Luminaire Spacing

63.1% 1.2

W/Sq Ft

6' x 6' (36 sq ft/luminaire)

70.7

1.49

8' x 8' (48 sq ft/luminaire)

45.3

0.95

59.6

1.68

30' x 30' x 8.5' Space

Electronic Ballast Input Watts (120V) Ballast Factor

FC

60.0W 0.88

Ordering Guide 2 X2 Flat Aluminum Door

Lamps qty/type

15/16" to 1-1/2" Wide Face T-Grid

2-6� T8 3-TT5 3-1.6" UT8

CXS2WFAVI26U CXS2WFAVI3FT CXS2WFAVI32U

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

CXS2WFAVI26U120S0 Basic catalogue number : Cleanguard wet location Class 1000 10,000 100,000 Clean Room

Application Data*

Reference Data Efficiency Spacing Ratio

Luminaire Spacing

67.9% 1.2

W/Sq Ft

8' x 8' (64 sq ft/luminaire)

75.5

1.51

8' x 10' (80 sq ft/luminaire)

94.3

1.88

66

1.77

30' x 30' x 8.5' Space

Electronic Ballast Input Watts (120V) Ballast Factor

FC

85.0W 0.88

Ordering Guide 2 X2 Flat Aluminum Door

120

SO

Voltage : Ballast : 120 See page 118 277 UNV Universal Voltage 120-277 T8 or TT5 only

Options : See page 118 Add appropriate suffix

Lamps qty/type

15/16" to 1-1/2" Wide Face T-Grid

2-T8 3-T8 4-T8

CXS2WFAVI232 CXS2WFAVI332 CXS2WFAVI432

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

CXS2WFAVI332 Basic catalogue number : Cleanguard wet location Class 1000 10,000 100,000 Clean Room

120

SO

Voltage : Ballast : 120 See page 118 277 UNV Universal Voltage 120-277 T8

Options : See page 118 Add appropriate suffix

Mounting Methods Exposed T-grid ceiling, 1-1/2" face, (with flat aluminum frame).

Exposed T-grid ceiling 15/16" to 1" face (with flat aluminum frame).

1/4" max.

1/4" max.

1 1/2" max.

1 1/2" max.

gasketing

gasketing

gasketing

gasketing

1-1/2" 24"

15/16" or 1" 24"

*Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor. RE835 lamp rated at 3000 lumens.

119


Special Application Luminaires

Cleanguard Class 10,000 - 2’x 2’, 2’x 4’ (CXS) Recessed Class 10,000 Clean Room / Wet Location Enclosed CXS2GFSVI26U120SO

90°

5" (127mm)

500 60°

24" (610mm) 1000

1500

SPECIAL APPLICATIONS

Features • Meets Excellent requirements for locationsforwhere Federal vandal Standard resistance 209E is required. • Class Prismatic 10,000 lens&(VL) 100,000 is 3/16" Clean thick Room pattern tested 12,byminimum Independent impact Lab. • UL strength, and ULc 130Listed foot pounds. for wet or damp locations for • covered Full perimeter ceilinggasketing use. (closed cell Neoprene) between door • Fits frame 15/16" and lens. to 1" wide face grid ceiling systems or flanged for • drywall Tamper resistant type ceilings. holt head Contractor screws responsible secure lens fortosealing housing. fixture • to 5" ceiling. deep body, 2x2 and 2x4. • Full 74.4% perimeter efficientgasketing (T8), 2x4 (closed 4 lamp.cell Neoprene) between door • frame Hemmed andover lens,side between rails for housing maximum and safety. door frame. • Ends Fixturesealed ends to turned-in body. for safe handling. • .125 Built-in pattern earthquake 12 lensclips installed (patent smooth no. 5,072,344), side down.on 2x2 and 2x4. • Door Springframe loaded is post rooster painted, head latches. baked acrylic enamel. • Hemmed 18 gauge over steelside hinges. rails for maximum safety. • Spring 69.3% loaded efficientrooster (T8), 2x2 head 2-6"U. latches. • 18 62.2% gauge efficient steel hinges. (T8), 1x4 2 lamp. • Flat and regressed aluminum doors available. Options Page 520 Options page 150-156 Ballast Specify voltage (120 or 277) and type and add as suffix, Ballast Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. 120S0. e.g. 120SO. Electrical/Wiring Options For special wiring, fusing, electronic dimming ballasts, consult factory. BALLAST CODE TYPE <20THD <10THD Seismic Hold-Down Clip For 1'x4' type G, Suffix: 2HD. Factory installed. Electronic T8 SO* HI* 1Plaster - 3 Lamp Elec T8 O3*order plaster frames H3* separately. Frame For F type troffers, 1Catalog - 4 Lamp Elec T8PF24 for 2'x4'O4* Number: troffer; PF22 for H4* 2'x2' troffer, PF14 Electronic TT5 (40 Watt) SB* IB* for 1'x4' troffer. 1Fusing - 3 Lamp TT5 (40 Watt) X3* SUFFIX: GLRI3* Internal fast-blowing fusing. Internal slow-blow *Instant Start GMF fusing. SUFFIX: Electrical/Wiring Options CODE For special wiring, BALLAST fusing, TYPE electronic dimming ballasts, <20THDconsult factory. <10THD Electronic T8 Order plaster frames SO* separately. HI* Plaster Frame 1-3 LampNumber: T8 O3*troffer, FK92X2H3* Catalog FK92X4 for 2'x4' for 2'x2' troffer. 1-4 Lamp T8 O4* H4* Fusing Suffix: F. 1-3 LampInternal TT5 40fast-blow Watt fusing. X3* I3* 1&2 Lamp TT5 40 Watt SB* IB* *Instant Start Lens For optional 9/64" thick (VK) pattern 12, minimum impact strength, 80 foot pounds, substitute VL with VK in Catalog No. i.e:GVS2GFSVK432.

120

30° 0°

RCR

C. U.

1 2

69 63

3 4

57 53

5 6

48 45

7 8

42 39

9 10

35 34

CXS2GFSVI332120O3

90°

5" (127mm) 24" (610mm)

750

60°

1500 2250

30° 0°

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 74 68 62 56 52 48 45 41 39 36


Special Application Luminaires

Application Data*

Reference Data Efficiency Spacing Ratio

63.1% 1.2

Electronic Ballast Input Watts (120V) Ballast Factor

60.0W 0.88

Luminaire Spacing

FC

W/Sq Ft

6' x 6' (36 sq ft/luminaire)

70.7

1.49

8' x 8' (64 sq ft/luminaire)

45.3

0.95

30' x 30' x 8.5' Space

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

59.6

Ordering Guide 2X2 Lamps qty/type Flat Aluminum Door

2-6” T8 3-TT5 3-1.6" UT8

Exposed T-Grid CXS2GFAVI26U CXS2GFAVI3FT CXS2GFAVI32U

Flat Steel Door

2-6” T8 3-TT5 3-1.6"U T8

CXS2GFSVI26U CXS2GFSVI3FT CXS2GFSVI32U

CXS2FFSVI26U CXS2FFSVI3FT CXS2FFSVI32U

Regressed Aluminum Door

2-6" T8 3-TT5 3-1.6"U T8

CXS2GRAVI26U CXS2GRAVI3FT CXS2GRAVI32U

CXS2FRAVI26U CXS2FRAVI3FT CXS2FRAVI32U

1.68

CXS2GFSVI26U Basic catalogue number : Cleanguard wet location Class 10,000 100,000 Clean Room

Application Data*

Reference Data Efficiency Spacing Ratio

67.9% 1.2

Electronic Ballast Input Watts (120V) Ballast Factor

85.0W 0.88

Luminaire Spacing

FC

W/Sq Ft

8' x 8' (64 sq ft/luminaire)

75.5

1.51

8' x 10' (80 sq ft/luminaire)

94.3

1.88

30' x 30' x 8.5' Space

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

66

Ordering Guide 2X4 Lamps qty/type Flat Aluminum Door

2-T8 3-T8 4-T8

Flat Steel Door

2-T8 3-T8 4-T8

Regressed Aluminum Door

2-T8 3-T8 4-T8

1.77

CXS2GFSVI332 Basic catalogue number : Class 10,000 100,000 Clean Room

*Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor. RE835 lamp rated at 3000 lumens.

120

Flanged forWide Dry or Plaster CXS2FFAVI26U CXS2FFAVI3FT CXS2FFAVI32U

SO

Voltage : Ballast : 120 See page 120 277 UNV Universal Voltage 120-277 T8 or TT5 only

Exposed T-Grid CXS2GFAVI232 CXS2GFAVI332 CXS2GFAVI432 CXS2GFSVI232 CXS2GFSVI332 CXS2GFSVI432 CXS2GRAVI232 CXS2GRAVI332 CXS2GRAVI432

120

Options : See page 120 Add appropriate suffix

Flanged forWide Dry or Plaster CXS2FFAVI2320 CXS2FFAVI332 CXS2FFAVI432 CXS2FFSVI232 CXS2FFSVI332 CXS2FFSVI432 CXS2FRAVI232 CXS2FRAVI332 CXS2FRAVI432

SO

Voltage : Ballast : 120 See page 120 277 UNV Universal Voltage 120-277 T8

Options : See page 120 Add appropriate suffix

121


Special Application Luminaires

Cleanguard Wet Location 1’x 4’, 2’x 2’, 2’x 4’ (WES) Recessed Lens / Wet Location Enclosed WES1GFAVA232120SO

90°

4-3/4" (44.4mm)

60°

12" (304.8mm) 30° 0°

SPECIAL APPLICATIONS 122

Features • UL Excellent and C-UL for Listed locations for where wet or vandal damp locations resistanceforiscovered required. • ceiling Prismatic use. lens (VL) is 3/16" thick pattern 12, minimum impact • Full strength, perimeter 130 foot gasketing pounds. (closed cell Neoprene) between door • frame Full perimeter and lens,gasketing between(closed housingcell andNeoprene) door frame. between door • Door frameframe and lens. is post painted, baked acrylic enamel. • 5" Tamper deep resistant body for 2x4 holt and head2x2. screws secure lens to housing. • 81.2% 5" deepefficient body, 2x2 (T8), and2x4 2x4. 4 lamp. • 71.6% 74.4% efficient (T8), 2-6"U. 2x4 4 lamp. • 64.6% Hemmed efficient over side (T8).rails 1x4for 2 lamp. maximum safety. • Hemmed Fixture ends overturned-in side railsforforsafe maximum handling. safety. • Fixture Built-in ends earthquake turned-in clips for(patent safe handling. no. 5,072,344), on 2x2 and 2x4. • Built-in Spring loaded earthquake rooster clips head (patent latches. no. 5,072,344) 2x4, 2x2. • Slimline 18 gaugedoor steelframe hinges. with 1000 square inch lens opening • on 69.3% 2x4 efficient door. (T8), 2x2 2-6"U. • Mitered 62.2% efficient corner steel (T8), 1x4 lens2frame. lamp. • Spring loaded rooster head latches. Options Page 520 • 18 gauge steel hinges. Ballast Specify voltage (120 or 277) type and add as suffix, • Flat and regressed aluminum doorsand available. e.g. 120S0. Options page 150-156 Electrical/Wiring Options For special wiring, fusing, electronic dimmingSpecify ballasts,voltage consult(120, factory. Ballast 277 or UNV) and type and add as suffix, e.g. 120SO. Seismic Hold-Down Clip For 1'x4' type G, Suffix: 2HD. Factory installed. BALLAST CODE Plaster order plaster<10THD frames separately. TYPE Frame For F type troffers, <20THD Catalog Number: PF24 for 2'x4' troffer; PF22 for 2'x2' Electronic T8 SO* HI* troffer, PF14 for troffer. 1 - 31'x4' Lamp Elec T8 O3* H3* Fusing Internal fast-blowing fusing. Internal slow-blow 1 - 4 Lamp Elec T8 O4* SUFFIX: GLRH4* fusing. SUFFIX: GMF Electronic TT5 (40 Watt) SB* IB* 1BALLAST - 3 Lamp TT5 (40 Watt) CODE X3* I3* *Instant TYPE Start <20THD <10THD Emergency/Wiring Options For fusing, electronic Electronic T8 SO*special wiring, HI* dimming ballasts, consult factory. 1-3 Lamp T8 O3* H3* Seismic Clip ForO4* 1'x4', type G, Suffix: 1-4 Lamp Hold-Down T8 H4*2HD. Factory Installed. 1-3 Lamp TT5 40 Watt X3* I3* 1&2 Lamp TT5 40 SB*plaster frames IB* Plaster Frame ForWatt F type F, order separately. Catalog *Instant Start Number: FK92X4 for 2'x4' troffer, FK92X2 for 2'x2' troffer; FK91X4 for 1’x4’ Lens troffer. For optional 9/64" thick (VK) pattern 12, minimum impact strength,Internal 80 footfast-blow pounds, substitute VL with Fusing fusing. SUFFIX: F. VK in Catalog No. i.e:GVS2GFSVK432. Continuous Row Installation For 1'x4'Cat. #: FK91X4-CRM

RCR

C. U.

1 2

71 65

3 4

60 56

5 6

51 48

7 8

44 41

9 10

37 35

WES2GFAVA26U120SO

90°

5" (127mm) 600

24" (610mm)

60°

1200

1800

30° 0°

RCR 1 2 3 4 5 6 7

C. U. 79 72 66 61 56 52 49

8 9

45 42

10

40

WES2GFAVA43212004

90°

5" (127mm) 24" (610mm)

1250

60°

2500 3750

30° 0°

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 89 82 75 69 64 59 55 51 48 45


Special Application Luminaires

Application Data*

Reference Data Efficiency Spacing Ratio

64.6% 1.3

Electronic Ballast Input Watts (120V) Ballast Factor

62.0W 0.88

Luminaire Spacing

FC

W/Sq Ft

8' x 8' (64 sq ft/luminaire)

50.4

1.23

8' x 10' (80 sq ft/luminaire)

39.2

0.96

69.6

2.5

50' x 70' x 8.5' Space

Ordering Guide 1X4

Lamps qty/type

Flat Steel Door Regressed Aluminum Door Flat Aluminum Door

2-T8 2-T8 2-T8

Exposed T-Grid WES1GFSVA232 WES1GRAVA232 WES1GFAVA232

Flanged forWide Dry or Plaster WES1FFSVA232 WES1FRAVA232 WES1FFAVA232

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

WES1GFAVA232 Basic catalogue number : Cleanguard wet location

Reference Data

Application Data*

Efficiency Spacing Ratio

Luminaire Spacing

71.6% 1.2

Electronic Ballast Input Watts (120V) Ballast Factor

60.0W 0.88

FC

W/Sq Ft

8' x 8' (64 sq ft/luminaire)

51.2

0.87

8' x 10' (80 sq ft/luminaire)

39.8

0.68

50' x 70' x 8.5' Space

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

70

1.76

Ordering Guide 2X2 Lamps qty/type Flat Steel Door

2-6" T8 3-TT5 3-1.6"U T8

Regressed Aluminum Door

2-6" T8 3-TT5 3-1.6"U T8

Flat Aluminum Door

2-6" T8 3-TT5 3-1.6"U T8

WES2GFAVA26U Basic catalogue number : Cleanguard wet location

Reference Data

Application Data*

Efficiency Spacing Ratio

Luminaire Spacing

81.2% 1.2

Electronic Ballast Input Watts (120V) Ballast Factor

83.0W 0.88

FC

W/Sq Ft

8' x 8' (64 sq ft/luminaire)

120.2

1.68

8' x 10' (80 sq ft/luminaire)

109.1

1.52

50' x 70' x 8.5' Space

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

108.9

2.26

Ordering Guide 2X4 Lamps qty/type Flat Steel Door

2-T8 3-T8 4-T8

Regressed Aluminum Door

2-T8 3-T8 4-T8

Flat Aluminum Door

2-T8 3-T8 4-T8

WES2GFAVA432 Basic catalogue number : Cleanguard wet location

*Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor. RE835 lamp rated at 3000 lumens.

120 Voltage : 120 277 UNV

SO

Ballast : Options : See page 122 See page 122

Exposed T-Grid WES2GFSVA26U WES2GFSVA3FT WES2GFSVA32U WES2GRAVA26U WES2GRAVA3FT WES2GRAVA32U WES2GFAVA26U WES2GFAVA3FT WES2GFAVA32U

120 Voltage : 120 277 UNV

Flanged forWide Dry or Plaster WES2FFSVA26U WES2FFSVA3FT WES2FFSVA32U WES2FRAVA26U WES2FRAVA3FT WES2FRAVA32U WES2FFAVA26U WES2FFAVA3FT WES2FFAVA32U

SO

GLR

Ballast : Options : See page 122 See page 122

Exposed T-Grid WES2GFSVA232 WES2GFSVA332 WES2GFSVA432 WES2GRAVA232 WES2GRAVA332 WES2GRAVA432 WES2GFAVA232 WES2GFAVA332 WES2GFAVA432

120

GLR

Flanged forWide Dry or Plaster WES2FFSVA232 WES2FFSVA332 WES2FFSVA432 WES2FRAVA232 WES2FRAVA332 WES2FRAVA432 WES2FFAVA232 WES2FFAVA332 WES2FFAVA432

SO

GLR

Voltage : Ballast : Options : 120 See page 122 See page 122 277 UNV universal voltage 120 277 Voltage Elec. T8 or TT5 only

123


Special Application Luminaire

RV Guardsman Corner Mount 2’, 3’, 4’, (RV) Surface Security for High Abuse Applications RVX1CXDUS232120SO

SPECIAL APPLICATIONS

RV Features Guardsman provides lighting solutions for maximum, medium, minimum securityfororlocations high abuse includes fixtures for surface, • Excellent whereareas. vandalIt resistance is required. recessed or corner wallis mounting A varietyimpact of tempered • Prismatic lens (VL) 3/16" thickapplications. pattern 12, minimum glass or polycarbonate lenses are available. To prevent forced access to strength, 130 foot pounds. the lampperimeter compartment there(closed is no protruding hardware anddoor all screws • Full gasketing cell Neoprene) between are frame tamperproof. and lens. • Tamper resistant holt head screws secure lens to housing. Features: • 5" deep body, 2x2 and 2x4. •• Post painted 14-20 body 74.4% efficient (T8),gauge 2x4 4CRS lamp. •• Overlapped and welded corners Hemmed over side rails for maximum safety. •• Door frame by for piano and 4 TORX screws Fixture endssecured turned-in safehinge handling. •• One piece CRS door frame in 14-20 CRS on 2x2 and 2x4. Built-in earthquake clips (patent no.gauge 5,072,344), •• Lens retained one piece frame Spring loadedby rooster headinner latches. •• Choice of prismatic acrylic, Prismatic polycarbonate or clear tem18 gauge steel hinges. • pered 69.3%glass efficient (T8), 2x2 2-6"U. •• 14 gauge cold rolled security) 62.2% efficient (T8), steel 1x4 2(maximum lamp. • 16 gauge cold rolled steel (medium security) Page 520 •Options 18 gauge cold rolled steel (minimum security) Ballast Specify voltage (120 or 277) and type and add as suffix, Options e.g. 120S0. Ballast Specifiy voltage (120,277 or 347v) and add suffix e.g.(120SO) Electrical/Wiring Options For special wiring, fusing, electronic Magnetic Electronic dimming ballasts, consult factory. T8:OC 1 or 2 LPB T8: SO Seismic Hold-Down Clip For 1'x4' type G, Suffix: 2HD. 3 LPB T8:O3 Factory installed. 4 LPB T8:O4 Plaster Frame For F type troffers, order plaster frames separately. LPB: Number of lamps per ballast Catalog Number: PF24 for 2'x4' troffer; PF22 for 2'x2' troffer, PF14 Electrical/Wiring Options:Consult factory for 1'x4' troffer. Fusing Internal fast-blowing fusing. SUFFIX: GLR Internal slow-blow fusing. SUFFIX: GMF BALLAST CODE TYPE <20THD <10THD Electronic T8 SO* HI* 1-3 Lamp T8 O3* H3* 1-4 Lamp T8 O4* H4* 1-3 Lamp TT5 40 Watt X3* I3* 1&2 Lamp TT5 40 Watt SB* IB* *Instant Start Lens For optional 9/64" thick (VK) pattern 12, minimum impact strength, 80 foot pounds, substitute VL with VK in Catalog No. i.e:GVS2GFSVK432.

124

RCR 90°

500 60° 1000

30° 0°

C. U.

1 2

44 39

3 4

36 33

5 6 7 8

30 27 25 23

9 10

21 20


Special Application Luminaires

Application Data*

Reference Data Efficiency Spacing Ratio

Luminaire Spacing

41.70%

FC

W/Sq Ft

31

1.9

22.4

1.19

23.2

1.78

10' x 12' x 10' Sobering Cell

Electronic Ballast

6' x 8' (48 sq ft/luminaire)

Input Watts (120V) Ballast Factor

62.0W 0.88

(6 inmates / 20 sq ft per inmate) 12' x 16' x 10' Space 6' x 4' (48 sq ft/luminaire) 8' x 8' x 10' Single Occupancy 6' x 8' (48 sq ft/luminaire)

Ordering Guide Lamp

2' long

3' long

4' long

Maximum Security

1-T8 2-T8 3-T8

Medium Security

1-T8 2-T8 3-T8

RVX1CXDUS117 RVX1CXDUS217 RVX1CXDUS317 RVD1CXDSUT17 RVD1CDSUT217 RVD1CDSUT317

RVX1CXDUS125 RVX1CXDUS225 RVX1CXDUS325 RVD1CDSUT125 RVD1CDSUT225 RVD1CDSUT325

RVX1CXDUS132 RVX1CXDUS232 RVX1CXDUS332 RVD1CDSUT132 RVD1CDSUT232 RVD1CDSUT332

Minimum Security

1-T8 2-T8 3-T8

Vandal Resistant

1-T8 2-T8 3-T8

RVN1CNSPY117 RVN1CNSPY217 RVN1CNSPY317 RVT1CFSVK117 RVT1CFSVK217 RVT1CFSVK317

RVN1CNSPY125 RVN1CNSPY225 RVN1CNSPY325 RVT1CFSVK125 RVT1CFSVK225 RVT1CFSVK325

RVN1CNSPY132 RVN1CNSPY232 RVN1CNSPY332 RVT1CFSVK132 RVT1CFSVK232 RVT1CFSVK332

RV

X

1

C

Luminaire Type

Luminaire Gauge

Luminaire Width

Mounting Style

RV SERIES

X: Maximum 14 Gauge Housing

1: Nominal 12"

C: Corner

D: Medium Security 16 Gauge Housing

N: Minimum Security 18 Gauge Housing

XD Door Frame

US Lens/Shielding

2

Lamp Quantity in a luminaire cross-section XD: Maximum US: .250" Clear 1: 1 lamp Security 14 Gauge Polycarbnoate with 2: 2 lamps Double Door Frame .125" acrylic overlay 3: 3 lamps with Piano hinge DS: Medium CG: Pattern 73 .140" Security 16 Gauge Tempered Glass Steel Door Frame with Piano hinge NS: Minimum UT: .125" Clear Security 18 Gauge Polycarbonate Steel Door Frame with .125" acrylic overlay PY: Pattern 12 .187" nominal Polycarbonate VK: Pattern 12 .140" Acrituff VX: Pattern 12 .125" nominal Polycarbonate

*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens

32

120

SO

Lamp/Type

Voltage

Ballast

Options

17: T8 17W

120

SO: Elect.T8 1-2 lamp I.S.

Consult factory

277

Consult factory for other ballast options

25: T8 25W 32: T8 32W

347

UNV

125


Security Fixtures

RV Guardsman Surface 1’x 4’, 2’x 2’, 2’x 4’ (RV) Surface Security For High Abuse Applications RVX1SXDUS232120SO

90° RCR

1000 60° 2000 30° 3000

SPECIAL APPLICATIONS

RV Guardsman provides lighting solutions for maximum, medium, miniFeatures mum securityfororlocations high abuse includes fixtures for surface, • Excellent whereareas. vandalItresistance is required. recessed or corner wall mounting A varietyimpact of tempered • Prismatic lens (VL) is 3/16" thickapplications. pattern 12, minimum glass or polycarbonate lenses are available. To prevent forced access to strength, 130 foot pounds. the lamp compartment there(closed is no protruding hardware anddoor all screws • Full perimeter gasketing cell Neoprene) between areframe tamperproof. and lens. • Tamper resistant holt head screws secure lens to housing. Features: • 5" deep body, 2x2 and 2x4. • Post painted 14-20 gauge CRS body • 74.4% efficient (T8), 2x4 4 lamp. • Overlapped and welded corners • Hemmed over side rails for maximum safety. • Door frame secured by piano hinge and 4 TORX scres • Fixture ends turned-in for safe handling. • One piece CRS door frame in 14-20 gauge CRS • Built-in earthquake clips (patent no. 5,072,344), on 2x2 and 2x4. • Lens retained by one piece inner frame • Spring loaded rooster head latches. • Choice of prismatic acrylic, Prismatic polycarbonate or clear tem• 18 gauge steel hinges. pered glass • 69.3% efficient (T8), 2x2 2-6"U. • 14 gauge cold rolled steel (maximum security) • 62.2% efficient (T8), 1x4 2 lamp. • 16 gauge cold rolled steel (medium security) Options Page 520 • 18 gauge cold rolled steel (minimum security) Ballast Specify voltage (120 or 277) and type and add as suffix, Options e.g. 120S0. Ballast Specifiy voltage (120,277 or 347v) and add suffix e.g.(120SO) Electrical/Wiring Options For special wiring, fusing, electronic Magnetic Electronic dimming ballasts, consult factory. T8:OC 1 or 2 LPB T8: SO Seismic Hold-Down Clip 1'x4' type G, Suffix: 2HD. 3 LPBFor T8:O3 Factory installed. 4 LPB T8:O4 Plaster Frame F type LPB: Number of For lamps per troffers, ballast order plaster frames separately. Catalog Number: PF24 for 2'x4' troffer; PF22 for 2'x2' troffer, PF14 Electrical/Wiring Options:Consult factory for 1'x4' troffer. Fusing Internal fast-blowing fusing. SUFFIX: GLR Internal slow-blow fusing. SUFFIX: GMF BALLAST CODE TYPE <20THD <10THD Electronic T8 SO* HI* 1-3 Lamp T8 O3* H3* 1-4 Lamp T8 O4* H4* 1-3 Lamp TT5 40 Watt X3* I3* 1&2 Lamp TT5 40 Watt SB* IB* *Instant Start Lens For optional 9/64" thick (VK) pattern 12, minimum impact strength, 80 foot pounds, substitute VL with VK in Catalog No. i.e:GVS2GFSVK432.

126

C. U.

1 2

47 43

3 4

40 37

5 6

34 32

7 8

29 27

9 10

25 23

RVX2SXDUS26U120SO 23 5/8"

90°

4 1/2"

400 60°

800

48"

30°

1200 0°

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 58 54 50 45 42 39 36 33 31 28

RVX2SXDUS432120O4 23 5/8"

4 1/2"

90°

400 800 48"

60°

1200 30° 0°

RCR 1 2 3 4 5

C. U. 57 52 49 45 41

6 7

38 35

8 9 10

32 30 28


Special Applications Luminaires

Application Data*

Reference Data Efficiency Spacing Ratio

Luminaire Spacing

41.70% 1.2

W/Sq Ft

33.6

1.9

10' x 12' x 10' Sobering Cell

Electronic Ballast

6' x 8' (48 sq ft/luminaire)

Input Watts (120V) Ballast Factor

FC

62.0W 0.88

(6 inmates / 20sq ft per inmate)

Ordering Guide RV Guardsman - (Surface Box)

Luminaire Size

Lamp

Maximum security Medium Security Minimum Security Vandal Resistant

1x4 2x2 2x2 2x2

2-T8 2-T8 2-T8 2-T8

Ordering Guide RV Guardsman - (Surface Box)

Luminaire Size

Lamp

2x2 2x2 2x2 2x2 2x2 2x2 2x2 2x2

2-T8 2-T8U6 2-T8 2-T8U6 2-T8 2-T8U6 2-T8 2-T8U6

Luminaire Size

Lamp

2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4

2-T8 3-T8 4-T8 2-T8 3-T8 4-T8 2-T8 3-T8 4-T8 2-T8 3-T8 4-T8

Catalogue Number RVX1SXDUS232 RVD1SXDUT232 RVN1SNSPY232 RVT1SFSVK232

8' x 8' x 10' Single Occupancy 6' x 4' (48 sq ft/luminaire)

25.6

1.78

Application Data*

Reference Data Efficiency Spacing Ratio

Luminaire Spacing

52.10% 1.2

W/Sq Ft

33.1

0.79

50' x 70' x 10'

Electronic Ballast

Maximum security

8' x 8' (64 sq ft/luminaire)

Input Watts (120V) Ballast Factor

FC

60.0W 0.88

Medium Security

12' x 16 x 10' 6' x 8' (48 sq ft/luminaire)

31.6

1.21

33.5

1.81

FC

W/Sq Ft

49.8

1.06

32.4

1.11

32.4

1.11

8' x 8' x 10'

Vandal Resistant

6' x 8' (48 sq ft/luminaire)

Application Data*

Reference Data Efficiency Spacing Ratio

Luminaire Spacing

51.00% 1.2

50' x 70' x 10'

Ordering Guide RV Guardsman - (Surface Box) Maximum security

Electronic Ballast Input Watts (120V) Ballast Factor

Minimum Security

8' x 8' (64 sq ft/luminaire) 112.0W 0.88

12' x 16 x 10

Medium Security

6' x 8' (48 sq ft/luminaire) 8' x 8' x 10'

Minimum Security

6' x 8' (48 sq ft/luminaire)

Vandal Resistant

Catalogue Number RVX2SXDUS217 RVX2SXDUS26U RVD2SDSUT217 RVD2SDSUT26U RVN2SNSPY217 RVN2SNSPY26U RVT2SFSVK217 RVT2SFSVK26U

Catalogue Number RVX2SXDUS232 RVX2SXDUS332 RVX2SXDUS432 RVXDSDSUT232 RVXDSDSUT332 RVXDSDSUT432 RVN2SNSPY232 RVN2SNSPY332 RVN2SNSPY432 RVT2SFSVK232 RVT2SFSVK332 RVX2SXDUS432

Ordering Guide

RV

X

1

S

Luminaire Type

Luminaire Gauge

Luminaire Width

Mounting Style

RV SERIES

X: Maximum 14 Gauge Housing

1: Nominal 12" 2: Nominal 24"

S: Surface

D: Medium Security 16 Gauge Housing

N: Minimum Security 18 Gauge Housing

XD Door Frame

US Lens/Shielding

2

Lamp Quantity in a luminaire cross-section XD: Maximum US: .250" Clear 2: 2 lamps Security 14 Gauge Polycarbnoate with 3: 3 lamps Double Door Frame .125" acrylic overlay 4: 4 lamps with Piano hinge DS: Medium CG: Pattern 73 .140" Security16 Gauge Tempered Glass Steel Door Frame with Piano hinge NS: Minimum UT: .125" Clear Security 18 Gauge Polycarbonate with Steel Door Frame .125" acrylic overlay PY: Pattern 12 .187" nominal Polycarbonate VK: Pattern 12 . 140" Acrituff VX: Pattern 12 .125" nominal Polycarbonate

*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens

32

120

04

Lamp/Type

Voltage

Ballast

Options

32: T8 32W

120

SO: Elect.T8 1-2 lamp I.S.

Consult factory

6U: 6� U-T8

277

03: Elect.T8 3-lamp I.S.

17: T8 17W

347

04: Elect.T8 4-lamp I.S.

UNV

Consult factory for other ballast options

127


Special Application luminaire

RV Guardsman Recessed 1’x 4’, 2’x 2’, 2’x 4’ (RV) Recessed Grid and Flange Security for High Abuse Applications RVX1FXDUS232120SO

RCR

53 49

3 4

45 42

400

5 6

39 35

800

7 60° 8

33 31

90°

SPECIAL APPLICATIONS

Features: Features • Post Excellent painted for 14-20 locations gauge where CRSvandal body resistance is required. • Overlapped Prismatic lens and(VL) welded is 3/16" corners thick pattern 12, minimum impact • Door strength, frame 130secured foot pounds. by piano hinge and 4 TORX scres • One Full perimeter piece CRSgasketing door frame (closed in 14-20 cellgauge Neoprene) CRS between door • Lens frameretained and lens. by one piece inner frame • Choice Tamper of resistant prismatic holtacrylic, head screws Prismatic secure polycarbonate lens to housing. or clear tem• pered 5" deepglass body, 2x2 and 2x4. • 14 74.4% gauge efficient cold rolled (T8), 2x4 steel4 (maximum lamp. security) • 16 Hemmed gauge over cold side rolledrails steel for(medium maximum security) safety. • 18 Fixture gauge ends coldturned-in rolled steel for safe (minimum handling. security) • Built-in earthquake clips (patent no. 5,072,344), on 2x2 and 2x4. Options • Spring loaded rooster head latches. Ballast Specifiy • 18 gauge steelvoltage hinges.(120,277 or 347v) and add suffix e.g.(120SO) Magnetic • 69.3% efficient (T8),Electronic 2x2 2-6"U. T8:OC or 22 LPB T8: SO • 62.2% efficient (T8),11x4 lamp. 3 LPB T8:O3 Options Page 520 4 LPB T8:O4 Ballast Specify voltageper (120 or 277) and type and add as suffix, LPB: Number of lamps ballast e.g. 120S0. Electrical/Wiring Options:Consult factory Electrical/Wiring Options For special wiring, fusing, electronic dimming ballasts, consult factory. Seismic Hold-Down Clip For 1'x4' type G, Suffix: 2HD. Factory installed. Plaster Frame For F type troffers, order plaster frames separately. Catalog Number: PF24 for 2'x4' troffer; PF22 for 2'x2' troffer, PF14 for 1'x4' troffer. Fusing Internal fast-blowing fusing. SUFFIX: GLR Internal slow-blow fusing. SUFFIX: GMF

9 10

30°

1200 0°

28 25

RVX2SXDUS26U120SO

21 31/32"

23 5/8" 24 7/8"

RCR 1 2 3 4 5 6 7 8

90°

24"

9 10

400 4 1/4"

800

C. U. 58 54 50 45 42 39 36 33 31 28

60°

1200 30°

24 1/4

25 1/2

BALLAST CODE TYPE <20THD <10THD Electronic T8 SO* HI* 1-3 Lamp T8 O3* H3* 1-4 Lamp T8 O4* H4* 1-3 Lamp TT5 40 Watt X3* I3* 1&2 Lamp TT5 40 Watt SB* IB* *Instant Start Lens For optional 9/64" thick (VK) pattern 12, minimum impact strength, 80 foot pounds, substitute VL with VK in Catalog No. i.e:GVS2GFSVK432.

RVX2FXDUS432120O4 4

1

3

5

21 31/32"

4 1/4"

23 5/8" 24 7/8" 2

6

7

5

48"

RCR 1 2 3 4 5 6 7 8 9 10

90°

1000

4 1/4"

60° 48 1/4"

2000

49 1/2" 8

128

C. U.

1 2

30° 3000

C. U. 57 53 49 45 42 39 35 33 30 29


Special Applications Luminaires

Application Data*

Reference Data Efficiency Spacing Ratio

Luminaire Spacing

47.20% 1.2

50' x 70' x 10'

Electronic Ballast

8' x 8' (64 sq ft/luminaire)

Input Watts (120V) Ballast Factor

Ordering Guide FC VCP W/Sq Ft

62.0W 0.88

27.8

0.71

30.7

1.23

32.8

1.85

Maximum Security Maximum Security Medium Security Minimum Security

12' x 16 x 10' 6' x 8' (48 sq ft/luminaire)

Vandal Resistant

Luminaire Size

Lamp

Catalogue Number

1x4 1x4 1x4 1x4 1x4 1x4 1x4

2-T8 2-T8 2-T8 2-T8 2-T8 2-T8 2-T8

RVX1SXDUS232 RVX1FXDUS232 RVD1FXDUT232 RVN1FNSPY232 RVN1GNSPY232 RVT1FFSVK232 RVT1GFSVK232

Luminaire Size

Lamp

Catalogue Number

2x2 2x2 2x2 2x2 2x2 2x2 2x2 2x2 2x2 2x2 2x2 2x2

2-T8 2-T8U6 2-T8 2-T8U6 2-T8 2-T8U6 2-T8 2-T8U6 2-T8 2-T8U6 2-T8 2-T8U6

RVX2FXDUS217 RVX2FXDUS26U RVD2FDSUT217 RVD2FDSUT26U RVN2FNSPY217 RVN2FNSPY26U RVN2GNSPY217 RVN2GNSPY26U RVT2FFSVK217 RVT2FFSVK26U RVT2GFSVK217 RVT2GFSVK26U

Luminaire Size

Lamp

Catalogue Number

2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4

2-T8 3-T8 4-T8 2-T8 3-T8 4-T8 2-T8 3-T8 4-T8 2-T8 3-T8 4-T8 2-T8 3-T8 4-T8 2-T8 3-T8 4-T8

RVX2FXDUS232 RVX2FXDUS332 RVX2FXDUS432 RVXDSDSUT232 RVXDSDSUT332 RVXDSDSUT432 RVN2FNSPY232 RVN2FNSPY332 RVN2FNSPY432 RVN2GNSPY232 RVN2GNSPY332 RVN2GNSPY432 RVT2FFSVK232 RVT2FFSVK332 RVT2FFSVK432 RVT2GFSVK232 RVT2GFSVK332 RVT2GFSVK432

8' x 8' x 10' 8' x 8' (64 sq ft/luminaire)

Reference Data

Application Data*

Efficiency Spacing Ratio

Luminaire Spacing

52.10% 1.2

Maximum Security

50' x 70' x 10'

Electronic Ballast

8' x 8' (64 sq ft/luminaire)

Input Watts (120V) Ballast Factor

Ordering Guide FC VCP W/Sq Ft

60.0W 0.88

33.1

0.79

31.6

1.21

33.5

1.81

12' x 16 x 10'

Medium Security Minimum Security

6' x 8' (48 sq ft/luminaire) 8' x 8' x 10' 6' x 8' (48 sq ft/luminaire)

Application Data*

Reference Data Efficiency Spacing Ratio

Luminaire Spacing

50.90% 1.2

Input Watts (120V) Ballast Factor

Ordering Guide FC VCP W/Sq Ft Maximum Security

50' x 70' x 10'

Electronic Ballast

Vandal Resistant

8' x 10' (80 sq ft/luminaire) 59.8

1.26 Medium Security

112.0W 0.88

8' x 8' x 10' 6' x 8' (48 sq ft/luminaire)

32.9

1.09

Minimum Security

Vandal Resistant

Ordering Guide

RV

X

2

F

Luminaire Type

Luminaire Gauge

Luminaire Width

Mounting Style

RV SERIES

X: Maximum 14 Gauge Housing

1: Nominal 12"

G: Std. T-Bar

D: Medium Security 2: Nominal 24" 16 Gauge Housing

N: Minimum Security 18 Gauge Housing

F: Flanged for Drywall

XD Door Frame

US Lens/Shielding

4

Lamp Quantity in a luminaire cross-section XD: Maximum US: .250" Clear 2: 2 lamps Security 14 Gauge Polycarbnoate with 3: 3 lamps Double Door Frame .125" acrylic overlay 4: 4 lamps with Piano hinge DS: Medium CG: Pattern 73 Security 16 Gauge .140" Tempered Glass Steel Door Frame with Piano hinge NS: Minimum UT: .125" Clear Security 18 Gauge Polycarbonate with Steel Door Frame .125" acrylic overlay PY: Pattern 12 .187" nominal Polycarbonate VK: Pattern 12 . 140" Acrituff VX: Pattern 12 .125" nominal Polycarbonate

32

120

04

Lamp/Type

Voltage

Ballast

Options

32: T8 32W

120

SO: Elect.T8 1-2 lamp I.S

Consult factory

277

03: 3 LPB T8 Electronic

347

04: 4 LPB T8 Electronic

UNV

Consult factory for other ballast options

129 *Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens


Special Application Luminaire

Guardsman Series - Recessed 1’x 4’, 2’x 2’, 2’x 4’ (GVS) Recessed Security for Vandal Resistant Applications GVS1GFSVL232120S0

90°

4-3/4" (44.4mm)

68 63

1000

3 4

58 53

1500

5 6

49 46

7 8

43 40

9 10

37 35

500

60°

30° 0°

SPECIAL APPLICATIONS

GVS2GFSVL26U120S0

90°

5" (127mm) 600

24" (610mm)

60°

1200

Options Page 520 page 150-156 Ballast Specify voltage (120 or 277) and type and add as suffix, e.g. 120S0. Electrical/Wiring Options For special wiring, fusing, electronic dimming ballasts, consult factory. SeismicFrame Plaster Hold-Down For F type Cliptroffers, For 1'x4'order typeplaster G, Suffix: frames 2HD.separately. Factory installed. Catalog Number: FK92X4 for 2'x4' troffer; FK92X2 for 2'x2' troffer, FK91X4 1'x4'For troffer. Plaster for Frame F type troffers, order plaster frames separately. Fusing Catalog Internal Number:fast-blowing PF24 for 2'x4' fusing. troffer; SUFFIX: PF22 Ffor 2'x2' troffer, PF14 for 1'x4' troffer. BALLAST CODE Fusing Internal fast-blowing <20THD fusing. SUFFIX: GLR Internal slow-blow TYPE <10THD fusing. SUFFIX: GMF Electronic T8 SO* HI* BALLAST CODE 1-3 Lamp T8 O3* H3* TYPE 1-4 Lamp T8 <20THD O4* <10THD H4* 1-3 Lamp TT5 X3* I3* Electronic T8 40 Watt SO* HI* 1&2 LampT8 TT5 40 Watt SB* IB* 1-3 Lamp O3* H3* *Instant 1-4 LampStart T8 O4* H4* 1-3 LensLamp For optional TT5 40 Watt 9/64" thick (VK) X3*pattern 12, minimum I3* impact 1&2 Lamp80TT5 strength, foot 40pounds, Watt substitute SB* VL with VK inIB* Catalog No. i.e:GVS2GFSVK432. *Instant Start Lens For optional 9/64" thick (VK) pattern 12, minimum impact strength, 80 foot pounds, substitute VL with VK in Catalog No. i.e:GVS2GFSVK432.

30°

1800 0°

RCR 1 2 3 4 5 6 7

C. U. 76 70 65 60 55 51 48

8 9

44 42

10

39

GVS2GFSVL432120S0

90°

5" (127mm) 24" (610mm)

1250

60°

2500 3750

30° 0°

130

C. U.

1 2

12" (304.8mm)

Features • Excellent for locations where vandal resistance is required. • Prismatic lens (VL) is 3/16" thick pattern 12, minimum impact strength, 130 foot pounds. • Full perimeter gasketing (closed cell Neoprene) between door frame and lens. • Tamper resistant holt head screws secure lens to housing. • 5" deep body, 2x2 and 2x4. • 74.4% efficient (T8), 2x4 4 lamp. • Hemmed over side rails for maximum safety. • Fixture ends turned-in for safe handling. • Built-in earthquake clips (patent no. 5,072,344), on 2x2 and 2x4. • Spring loaded rooster head latches. • 18 gauge steel hinges. • 69.3% efficient (T8), 2x2 2-6"U. • 62.2% efficient (T8), 1x4 2 lamp.

RCR

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 82 75 69 64 59 55 51 47 44 42


Recessed Fluorescent Luminaires Application Data*

Reference Data Efficiency Spacing Ratio

62.2% 1.2

Electronic Ballast Input Watts (120V) Ballast Factor

62.0W 0.88

Luminaire Spacing

FC

W/Sq Ft

8' x 8' (64 sq ft/luminaire)

41.1

0.81

8' x 10' (80 sq ft/luminaire)

35.9

0.71

42.5

1.23

50' x 70' x 8.5' Space

Ordering Guide Fixture size 1x4 Flat Steel Door

Lamps qty/type 2-T8

Exposed T-Grid GVS1GFSVL232

Flanged forWide Dry or Plaster GVS1FFSVL232

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

GVS1GFSVL232 Basic catalogue number :

Application Data*

Reference Data Efficiency Spacing Ratio

69.3% 1.2

Electronic Ballast Input Watts (120V) Ballast Factor

60.0W 0.88

Luminaire Spacing

FC

W/Sq Ft

8' x 8' (64 sq ft/luminaire)

49.7

0.87

8' x 10' (80 sq ft/luminaire)

38.6

0.68

45.8

1.18

50' x 70' x 8.5' Space

Ordering Guide Fixture size 2x2 Flat Steel Door

Lamps qty/type 2-6” T8 3-TT5 3-1.6”U T8

120 Voltage : 120 277

SO Ballast : Options : See page 130 See page 130

Exposed T-Grid GVS2GFSVL26U GVS2GFSVL3FT GVS2GFSVL32U

Flanged forWide Dry or Plaster GVS2FFSVL26U GVS2FFSVL3FT GVS2FFSVL32U

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

GVS2GFSVL26U Basic catalogue number :

Application Data*

Reference Data Efficiency Spacing Ratio

74.4% 1.2

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing

W/Sq Ft

86

1.26

50.7

1.10

50' x 70' x 8.5' Space 8' x 10' (80 sq ft/luminaire)

112.0W 0.88

FC

Ordering Guide Fixture size 2x4 Flat Steel Door

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

Lamps qty/type 2- T8 3- T8 4- T8

GVS2GFSVL432 Basic catalogue number :

*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens

120 Voltage : 120 277

SO Ballast : Options : See page 130 See page 130

Exposed T-Grid GVS2GFSVL232 GVS2GFSVL332 GVS2GFSVL432

120 Voltage : 120 277

Flanged forWide Dry or Plaster GVS2FFSVL232 GVS2FFSVL332 GVS2FFSVL432

04 Ballast : Options : See page 130 See page 130 Add appropriate suffix to catalog no., ie: (GLR)

131


Special Application Luminaire

Guardsman series - Surface 1’x 4’, 2’x 2’, 2’x 4’ (GVB) Surface Security for Vandal resistant Applications GVB1SFSVL232120S0

90°

5-1/2" (140mm)

500

60°

1000

12" (305mm) 1500

30° 0°

SPECIAL APPLICATIONS

Features • Excellent for locations where vandal resistance is required. • 20 gauge steel body. • Prismatic lens (VL) is 3/16" thick, pattern 12, minimum impact strength, 130 foot pounds. • Full perimeter gasketing (closed cell Neoprene) between door frame and lens. • Tamper resistant holt head screws secure lens to housing. • 45° mitered corners (body and door frame). • Only 5-1/2" deep. • 54.9% efficient (2 lamp T8).1x4 • Side mounted ballast for cooler operation. 1x4 • Fully enclosed wiring. • 55.5% efficient (2U lamp T8). • Side mounted ballast for cooler operation. 2x2 • 65.2% efficient (4 lamp T8). • Side mounted ballast for cooler operation. 2x4

RCR

C. U.

1 2

60 56

3 4

51 48

5 6

44 41

7 8

38 36

9 10

33 31

GVB2SFSVL26U120S0

90° 5-1/2" (140mm) 450

60°

24" (610mm) 900

Options page 150-156 Ballast Specify voltage (120 or 277) and type and add as suffix, e.g. 120SO.

1350

30° 0°

Electrical/Wiring Options For special wiring, fusing, electronic dimming ballasts, or emergency pack, consult factory.

RCR 1

C. U. 61

2 3

56 52

4 5 6 7 8 9 10

48 44 41 38 36 33 31

Fusing Internal fast-blowing fusing. SUFFIX: F BALLAST TYPE Electronic T8 1-3 Lamp T8 1-4 Lamp T8 Electronic TT5 (40 Watt) 1-3 Lamp TT5 (40 Watt) * Instant start

CODE <20THD SO* O3* O4* SB* X3*

<10THD HI* H3* H4* IB* I3*

GVB2SFSVL43212004

Lens: For optional 9/64” thick (VK) pattern 12, minimum impact strength 80 foot pounds, substitute VL with VK in catalog no. ie GVB2SFSVK432

90°

5-1/2" (140mm) 1050

60°

24" (610mm) 2100 3150

30° 0°

132

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 72 66 60 56 52 48 44 41 39 36


Special Application Luminaires

Application Data*

Reference Data Efficiency Spacing Ratio

54.9% 1.2

Electronic Ballast Input Watts (120V) Ballast Factor

62.0W 0.88

Luminaire Spacing

FC

W/Sq Ft

8' x 8' (48 sq ft/luminaire)

41.3

0.86

8' x 10' (80 sq ft/luminaire)

32.1

0.67

39.2

1.16

50' x 70' x 8.5' Space

Ordering Guide Fixture size 1x4 Flat Steel Door

Lamps qty/type

Surface Box GVB1SFSVL232

2-T8

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

120

GVB1SFSVL232 Basic catalogue number :

Reference Data

Application Data*

Efficiency Spacing Ratio

Luminaire Spacing

55.5% 1.2

Electronic Ballast Input Watts (120V) Ballast Factor

60.0W 0.88

FC

W/Sq Ft

8' x 8' (64 sq ft/luminaire)

40.1

0.94

8' x 10' (80 sq ft/luminaire)

21.2

0.73

56.8

1.9

50' x 70' x 8.5' Space

Ordering Guide Fixture size 2x2 Flat Steel Door

Voltage : 120 277

SO Ballast : Options : See page 132 See page 132

Lamps qty/type

Surface Box GVB2SFSVL26U GVB2SFSVL3FT GVB2SFSVL32U

2-6” T8 3-TT5 3-1.6”U T8

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

120

GVB2SFSVL26U Basic catalogue number :

Application Data*

Reference Data Efficiency Spacing Ratio

65.2% 1.2

Electronic Ballast Input Watts (120V) Ballast Factor

112.0W 0.88

Luminaire Spacing

FC

W/Sq Ft

8' x 8' (64 sq ft/luminaire)

97.5

1.75

8' x 10' (80 sq ft/luminaire)

75.9

1.36

68.6

1.77

50' x 70' x 8.5' Space

Ordering Guide Fixture size 2x4 Flat Steel Door

Voltage : 120 277

SO Ballast : Options : See page 132 See page 132

Lamps qty/type

Surface Box GVB2SFSVL232 GVB2SFSVL332 GVB2SFSVL432

2- T8 3- T8 4- T8

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

GVB2SFSVL432 Basic catalogue number :

* Pieds-bougies moyens maintenus. LLF Total = .75 Réflectivité : Plafond :80% mur : 50% plancher : 20%. Lampe de type RE835 évaluée à 3000 lumens.

120 Voltage : 120 277

04 Ballast : Options : See page 132 See page 132

133


Special Application Luminaire

Guardsman Series - Wrap Surface 4’, 8’ (GVW) Surface Vandal Wrap security for Vandal resistant Applications GV4WA232120SO

90° 2 7/8" (73mm) 60° 10 5/16" (262mm)

30° 0°

SPECIAL APPLICATIONS

Features • Excellent for locations where vandal resistance is required. • Prismatic lens is 50% DR (impact resistant), and 50% standard acrylic with a nominal thickness of 1/8", withstands 70 ft. lbs. impact without breaking. • Tamper resistant holt head screws secure lens to housing. • UL-Listed for direct mounting on low density ceilings and damp locations. • Steel end caps, standard. • Self-aligning for continuous row mounting. • Heavy duty, die formed channel of code gauge steel.

CODE <20THD SO* O3* O4*

<10THD HI* H3* H4*

C. U.

1 2

91 82

3 4

76 68

5 6

64 58

7 8

54 50

9 10

46 40

GV4WB332120O3

Options page 150-156 Ballast Specify voltage (120 or 277) and type and add as suffix, e.g. 120SO. BALLAST TYPE Electronic T8 1-3 Lamp T8 1-4 Lamp T8 * Instant Start

RCR

90°

2-7/8" (73mm)

60°

15-5/16" (389mm)

30° 0°

Electrical/Wiring Options For special wiring, fusing, electronic dimming ballasts, consult factory.

RCR

C. U.

1 2

85 78

3 4 5 6 7 8 9 10

71 66 60 56 52 47 45 41

Fusing Internal fast-blowing fusing. SUFFIX: F

GV4WB432120O4

90°

2-7/8" (73mm)

60°

15-5/16" (389mm)

30° 0°

134

RCR 1 2 3 4 5 6 7 8 9 10

C. U. 83 77 70 65 59 55 51 47 45 41


Fluorescent Wraparound Luminaires Application Data*

Reference Data Efficiency Spacing Ratio

65.0% 1.2

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing

W/Sq Ft

50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

62.0W 0.88

FC

55.9

1.36

55.3

1.52

12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

Efficiency Spacing Ratio

Electronic Ballast Input Watts (120V) Ballast Factor

Luminaire Spacing

120

GV4WA232

49.4

1.78

FC

W/Sq Ft

Voltage : 120 277

Ordering Guide Width Length

Lamp Type/Qty

15 5/16”

3-T8

91

2.27

92.8

2.61

41.4

1.53

FC

W/Sq Ft

30' x 30' x 8.5' Space 8' x 8' (48 sq ft/luminaire)

48”

6' x 8' (48 sq ft/luminaire)

Efficiency Spacing Ratio

Application Data* 70.1% 1.4

Luminaire Spacing 50' x 70' x 8.5' Space

Electronic Ballast Input Watts (120V) Ballast Factor

8' x 8' (64 sq ft/luminaire) 112.0W 0.88

SO Ballast : Options : See page 134 See page 134

Surface Wraparound GV4WB332

120

GV4WB332 Basic catalogue number :

Voltage : 120 277

12' x 16' x 8.5' Space

Reference Data

Surface Wraparound GV4WA232 GV8WA232

50' x 70' x 8.5' Space 8' x 8' (64 sq ft/luminaire)

85.0W 0.88

2-T8 2-T8 in Tandem (4 total)

48” 96”

Basic catalogue number :

Application Data* 75.4% 1.2

Lamp Type/Qty

10 5/16” 10 5/16”

30' x 30' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

Reference Data

Ordering Guide Width Length

100.2

2.52

115.6

3.27

77.6

2.28

Ordering Guide Width Length

Lamp Type/Qty

15 5/16” 15 5/16”

2- T8 4- T8

48” 48”

SO Ballast : Options : See page 134 See page 134

Surface Wraparound GV4WB232 GV4WB432

30' x 30' x 8.5' Space 6' x 8' (48 sq ft/luminaire) 12' x 16' x 8.5' Space 6' x 8' (48 sq ft/luminaire)

GV4WB432 Basic catalogue number :

* Pieds-bougies moyens maintenus. LLF Total = .75 Réflectivité : Plafond :80% mur : 50% plancher : 20%. Lampe de type RE835 évaluée à 3000 lumens.

120 Voltage : 120 277

SO Ballast : Options : See page 134 See page 134

135


Special Application Luminaire

Guardsman Series - Wrap Surface 2’, 4’ (GSW) Surface Vandal Wrap Security for Vandal Resistant Applications GSW4232120S0 6" (152mm)

90° 400

60°

3-7/8" (98mm)

800 1200 30° 0°

SPECIAL APPLICATIONS

Features • Excellent for locations where vandal resistance is required, areas such as hallways, stairwells, locker rooms, parking garages and psychiatric hospitals. • For ceiling or wall mounted applications. • Can be vertically or horizontally mounted on wall. • 20 gauge cold rolled steel, post painted, baked white enamel housing. • 18 gauge cold rolled steel post painted baked white enamel end caps, standard. • Linear prismatic lens 50% DR (impact resistant) and 50% standard acrylic with nominal thickness of 1/8", withstands 70 ft lbs impact without breaking. • Tamper resistant holt head screws secure ends to housing. • Only 3-7/8" deep, meets American with Disabilities Act for wall mounted fixtures. • Nominal 2' and 4' lengths. • 73.9% efficient (T8 lamps). Options

page 150-156

Ballast Specify voltage (120, 277or UNV) and type and add as suffix, e.g. 120SO. BALLAST TYPE Electronic T8 *Instant Start

CODE <20THD SO*

<10THD HI*

Electrical/Wiring Options For special wiring, fusing, electronic dimming ballasts, consult factory. Fusing Internal fast-blowing fusing. SUFFIX: F

136

RCR

C. U.

1 2

81 73

3 4

66 61

5 6

56 51

7 8

48 44

9 10

41 39


Ceiling or Wall-Mounted Fluorescent Application Data*

Reference Data Efficiency Spacing Ratio

Luminaire Spacing

73.9% 1.3

W/Sq Ft

50.1

1.73

41.5

1.15

70.3

1.73

4' W x 40' L x 8.5' H Corridor

Electronic Ballast Input Watts (120V) Ballast Factor

FC

8' center (single row) 62.0W 0.88

6' W x 40' L x 8.5' H Corridor 8' center (single row)

Ordering Guide Type Fixture Length

Lamp Length

Lamp Type / Qty

GSW Vandal Resistant Ceiling or Wall

2' 2' 4' 4'

1-T8 2-T8 1-T8 2-T8

23- 15/16” 23- 15/16” 48" 48”

Catalog Number GSW2117 GSW2217 GSW4132 GSW4232

8' W x 40' L x 8.5' H Corridor 4' x 8' (32 sq ft/luminaire)

GSW4232 Basic catalogue number : GSW Series

7/8" dia. K.O. (2)

120

SO

Voltage : Ballast : Options : 120 See page 136 See page 136 277 UNV Universal Voltage 120-277 T8

9/32" hole (2)

4" (102mm) 6" (152mm) 23-15/16" (608mm) 9/32" hole (2)

7/8" dia. K.O. (3)

1-7/8" dia. K.O.

4" (102mm) 6" (152mm)

24" (610mm) 48" (1219mm)

End Cap

Threaded Nipple

End Cap

Nut

Nut

Nut Required to space fixtures apart so ends can be removed or installed.

For continuous row mounting (supplied by others).

*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens

137


Medical Luminaires

MD*4 Series 2’x 2’, 2’x 4’ (MD4) Multi-Function Patient Room Luminaire • Ambient / Reading / Examination / Nurse’s Night Light MD4 2’x 4’

6-7/8" (175 mm) 48" (1219 mm)

Ceiling

MEDICAL

MD*4 combines all of the lighting functions in a patient’s room in a single luminaire that is ceiling mounted to permit clean headwalls. This enables architects and interior designers to create a more home-like environment and moves the light luminaire off the wall, a location where it can be damaged easily or interfere with medical equipment. MD*4 is more efficient and more economical than all other patient lighting systems. Features •2 x 4 Unit has four lighting functions with integral ambient, reading, examination and optional nurse’s night light. •2 x 2 Unit has three lighting functions with integral ambient, reading, and optional nurse’s night light. •Specular aluminum reflectors for precise light control and glare free patient environment. •Installs as a one-piece unit. Recessed or surface mounted to ceiling against wall directly behind patient. Eliminates damage to luminaire from hospital equipment attached to patient bed. •6-7/8” deep. •Top wiring access plate is standard. •All lamps are enclosed. •All TT5 type lamps (not included) are accessible for relamping without tools. •Rugged 20 gauge steel housing. •Optional low voltage (1-3 volts) electronic sequential switch mounted in luminaire for ambient and reading light controlled with pillow switch (by others). •Examination Light in 2 x 4 has 36 cell specular aluminum parabolic louver with pattern 12 lens overlay.

Ceiling

Wall Wall

Secure Luminaire Secure Luminaire (4 (4Places) Places) Wall Wall angle angle T-bar ororT-bar by others by others

48" (1219 mm) Wall Wall

Acoustical tile Acoustical tilebybyothers others

MD2 2’x 2’ (2 types of lighting : ambient / reading)

6-7/8" (175 mm)

Options pages 150-156 Electronic (Low Voltage) Sequential Switch Switch factory mounted in luminaire for ambient and reading light convenience (controlled by pillow switch, by others). Suffix: SW. (N/A 347V) Nurse Night Light 120V medium base, narrow spot, 50W PAR 20 reflector lamp included with specular anodized mirror, field adjustable to right or left side of patients bed. Suffix: NL. Fusing Suffix: F. Electrical/Wiring Options Consult factory. Tamper Proof Consult factory. Germ Guard Order Catalogue No., MD4CLGS24.

24" (610 mm)

Ceiling Ceiling

Wall

Secure SecureLuminaire Luminaire Places) (4(4Places) Wall Wall angle angle T-bar ororT-bar others bybyothers

Sequential switch (SW)

138

24" (610 mm) Wall Wall

Acousticaltile tileby others Acoustical by others


Medical Luminaires

Ordering Guide

Examination Light Excellent colour rendition. (82 CRI TT5 Type lamp) Wired for independent switching (1 or 2 circuit).

Type

Footcandles on Bed (with Specular Louver) (Totals of Ambient, Reading and examination lights)

Examination light shielding

WALL

MD*4 36 Cell 2'x4' Low Iridescence with Specular Louver Ambient, with Prismatic Reading Overlay and Examination Light

BED

Total qty of lamps*

Ballast type

Grid ceiling

6-TT5 6-TT5 5-TT5 5-TT5

40W Electro-mag. 40W Electronic 40W Electro-mag. 40W Electronic

MD4GPSVA2BX4 MD4GPSVA2SB4 MD4GPSVA2BX3 MD4GPSVA2SB3

*Include 2-TT5 for ambiant / reading section.

Numbers in parenthesis ( ) are total footcandle level of ambient and reading lights only.

Reading Light Eliminates reflected glare from reading material (over the shoulder illumination). No direct glare to patient or visitors. (7 footcandles maximum at head of bed. 15 footcandles maximum at foot of bed.) Controls light directly onto patients bed. No reading light spill-over to adjacent beds. (1 footcandle maximum at head of adjacent patient’s bed.) Footcandles on Bed (Horizontal) Reading Light/On

1

MD4GPSVA2BX4 Basic catalogue number : Multi-function Examination Luminaire

Voltage : 1=120 2=277 3=347

SW Options : Electronic Sequential Switch

NL Options : Nurses Night Light

Options : See page 138 Add appropriate suffix to catalogue number

Adjacent MD*4 Off

WALL

BED

BED

Illumination at the reading task ranges 50-80 footcandles.

Ordering Guide Type Ballast type

Ambient Light Indirect illumination from wall directly behind patient provides glare-free lighting. No direct glare to patient (Light is directed towards wall.) No direct glare to patients visitor. No direct glare to adjacent patients. (3 footcandles maximum on wall behind adjacent patient’s bed.) Ambient Light/On

MD*2 2'x2' with Ambient, and Reading Light

Adjacent MD*4/Off

40W Electro-magnetic 40W Electronic

MD2G2BX Basic catalogue number : Multi-function Patient Luminaire

Footcandles on Beds Reading Light/On

Number of lamps

120 Voltage : 120 277 347

2-TT5 2-TT5

SW Options : Electronic Sequential Switch

Grid ceiling MD2G2BX MD2G2SB

NL Options : Nurses Night Light

Options : See page 138 Add appropriate suffix to catalogue number

Adjacent MD*4 Off Wall

Reading Light Eliminates reflected glare from reading material (over the shoulder illumination). No direct glare to patient or visitor. (7 footcandles maximum at head of bed. 15 footcandles maximum at foot of bed.) Controls light directly onto patients bed. No reading light spill-over to adjacent beds. (1 footcandle maximum at head of adjacent patient’s bed.) BED

BED

Illumination at the reading task ranges 50-60 footcandles

139


Medical Luminaires

MD* Coffer 2’x 2’, 2’x 4’ (MDC) Multi-Function Patient Room Luminaire • Ambient / Reading / Examination / Nurse’s Night Light MD*Coffer 2’x 4’

6-7/8" (175 mm)

Ceiling

MEDICAL

MD*Coffer combines all of the lighting functions in a patient’s room in a single luminaire that is ceiling mounted to permit clean headwalls. This enables architects and interior designers to create a more home like environment and moves the light luminaire off the wall, a location where it can be damaged easily or interfere with medical equipment. MD*Coffer is more efficient and more economical than all other patient lighting systems. Features •2 x 4 Unit has four lighting functions with integral ambient, reading, examination and optional nurse’s night light. •2 x 2 Unit has three lighting functions with integral ambient, reading, and optional nurse’s night light with perforated mesh shield. •Specular aluminum reflectors for precise light control and glare free patient environment. •Installs as a one-piece unit. Recessed or surface mounted to ceiling against wall directly behind patient. Eliminates damage to luminaire from hospital equipment attached to patient bed. •Top wiring access plate is standard. •All TT5 type lamps (not included) are accessible for relamping without tools. All lamps are enclosed. •Rugged 20 gauge steel housing. •Optional low voltage (1-3 volts) electronic sequential switch mounted in luminaire for ambient and reading light controlled with pillow switch (by others). •Examination Light in 2 x 4 has 36 cell flat white baked enamel louver with pattern 12 lens overlay. •Perforated mesh shield for ambient / reading section.

Wall

Wall Accoustical tile angle (by others) or T-bar (by others)

Wall

Accoustical tile (by others)

9’6” max. mounting height

48" (1219 mm)

Ceiling

Wall angle or T-bar (by others)

140

Luminaire fixé en 4 points

6-7/8" (175 mm)

Wall

Sequential switch (SW)

Mount 12” - 18” from wall

9’6” max. mounting height

MD*Coffer 2’x 2’ (2 types of lighting : ambient / reading)

Options pages 150-156 347 Volt — Change 120 to 347 (e.g. MDCGWSVA2BX4BX120, MDCGWSVA2BX4BX347). Electronic (Low Voltage) Sequential Switch Switch factory mounted in luminaire for ambient and reading light convenience (controlled by pillow switch, by others). Suffix: SW. (N/A 347V) 9/7 Watt Night Light Suffix: PL (Lamp not included). Fusing Suffix: F. Electrical/Wiring Options Consult factory. Tamper Proof Consult factory. Germ Guard Order Catalogue No., MD4CLGS24.

PL9 or PL7 Night Light (PL) (Lamps not included)

Mount 12” - 18” from wall

Wall

Mount 12” - 18” from wall

Accoustical tile (by others)

Mount 12” - 18” from wall

9’6” max. mounting height

Secure luminaire (4 places)

Accoustical tile (by others)

9’6” max. mounting height

24" (610 mm)


Medical Luminaires

AMBIENT LIGHT

Ordering Guide

Indirect illumination from TT5 shielded by perforated mesh shield with white acrylic overlay. No direct glare to patient. No direct glare to patients visitor. No direct glare to adjacent patients.

Type

Examination Total qty light shielding of lamps*

Ballast type

Grid ceiling

MD*Coffer 2' x 4' with

36 Cell white

6-TT5 6-TT5

40W Electro-mag. 40W Electronic

Ambient, Reading

louver with Prismatic

5-TT5 5-TT5

40W Electro-mag. 40W Electronic

MDCGWSVA2BX4 MDCGWSVA2SB4 MDCGWSVA2BX3 MDCGWSVA2SB3

and

Overlay

3"

6" 12"

Lighted Zone

Wall

14

15

15

14

12

12

7

14

16

16

14

12

12

8

Examination Light

14

15

15

14

12

12

7

*Include 2-TT5 for ambiant / reading section.

12"

Bed

1

MDCGWSVA2BX4

FOOTCANDLES ON BED

Basic catalogue number : Multi-function Examination Luminaire

Voltage : 1=120 2=277 3=347

SW Options : Electronic Sequential Switch

NL Options : Nurses Night Light

Options : See page 140 Add appropriate suffix to catalogue number

READING LIGHT Eliminates reflected glare from reading material (over shoulder illumination). No direct glare to patient or visitors. Controls light directly onto patient’s bed. 3"

EXAMINATION LIGHT Excellent colour rendition. Wired for independent switching (1 or 2 circuit). Optional louver or lens frame. Concealed hinging and latching.

6" 12"

Lighted Zone 17 Wall

21

23

28

33

6

5

3"

12" 18

22

24

29

35

6

5

17

21

23

28

33

6

5

Lighted Zone

Wall

6"

12"

68 (31)

85 (36)

93 (38)

99 (42)

100 (45)

65 (18)

49 (12)

73 (32)

89 (38)

99 (40)

104 (43)

106 (47)

68 (18)

53 (13)

68 (31)

85 (36)

93 (38)

99 (42)

100 (45)

65 (18)

49 (12)

12"

Bed Illumination at the reading task ranges 45-50 footcandles.

Bed

FOOTCANDLES ON BED

FOOTCANDLES ON BED Totals of ambient, reading and examination lights. Numbers in parenthesis ( ) are total footcandle level of ambient and reading lights only.

Ordering Guide

AMBIENT LIGHT Indirect illumination from TT5 shielded by perforated mesh shield with white acrylic overlay. No direct glare to patient. No direct glare to patients visitor. No direct glare to adjacent patients. 3"

6" 12"

Lighted Zone

Wall

14

15

15

14

12

12

7

14

16

16

14

12

12

8

14

15

15

14

12

12

7

12"

Type

Ballast type

Number of lamps

Grid ceiling

MD*Coffer

40W Electro-magnetic

2-TT5

2' x 2' with Ambient, and Reading Light

40W Electronic

2-TT5

MDCG2BX MDCG2SB

120

MDCG2BX

Bed

FOOTCANDLES ON BED

Basic catalogue number : Multi-function Patient Luminaire

READING LIGHT

Voltage : 120 277 347

SW Options : Electronic Sequential Switch

NL Options : Nurses Night Light

Options : See page 140 Add appropriate suffix to catalogue number

Eliminates reflected glare from reading material (over shoulder illumination). No direct glare to patient or visitors. Controls light directly onto patient’s bed. 3"

6" 12"

NIGHT LIGHT (Optional)

Lighted Zone

Wall

17

21

23

28

33

6

5

18

22

24

29

35

6

5

17

21

23

28

33

6

5

Indirect 9 or 7 watt PL lamp shielded by perforated mesh with internal white acrylic overlay. No glare to any patient. Wired for independent switching. 12"

3"

Bed Illumination at the reading task ranges 45-50 footcandles.

6"

12"

3

4

3

3

2

2

1

3

4

3

3

2

2

1

3

4

3

3

2

2

1

FOOTCANDLES ON BED

12" Wall

Bed

FOOTCANDLES ON BED

141


Medical Luminaires

SUS 432 / 632 2’x 4’ Operating Room Luminaire SUS2GFSMA632120O6 (Data)

RCR

5" (127 mm)

0

24" (610 mm) 1000

60°

MEDICAL

Features •Asymmetric/symmetric distribution provides: Supplemental illumination to operating tables. Minimizes contrast between surgical and surrounding areas. •Meets government specification for Radio Frequency Interference (RFI), MIL-STD 461-A, MIL-STD 463. •One radio suppressor per luminaire (standard). •High efficiency 60.9% (6 light), 61.2% (4 light). •One-piece housing is embossed construction for added strength. •Built-in hold-down clips. •Flat full-size steel lens frame is gasketed. •Black housing exterior for cooler ballast operating temperature. •Turned-in edges for safe handling.

2000

60°

C. U.

1 2

64 56

3 4

50 45

5 6

40 36

7 8

33 30

9 10

28 25

3000

4252

Black housing exterior for cooler ballast operating temperature

30°

30°

One piece-housing is embossed construction for added strength

Fully gasketed lens frame Turned-up edges for safe handling

Lens frame Symmetrical distribution jamb finished black for positive light stop

Asymmetrical distribution

SUS2GFSMA432120O4 (Data)

built-in hold-down clip before installation

hold-down clip installed (lay-in grid)

Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO. Magnetic Electronic PowerSpec Dimming T8: OC T8: SO T8: PS 2 x 3 LPB T8: O6 (not avail. in 347V) 4 LPB T8: O4 For T12 lamp see page 151. LPB : Number of lamps per ballast. Continuous Row Installation For F type luminaires, half-width flanges are required between luminaires. Catalogue number FK92X4-CRM. Plaster Frames F type luminaires do include plaster frames. G type luminaires require FK92X4 universal frame kit. Electrical/Wiring Options Consult Factory. Fusing Internal fast-blow fusing. Suffix: F. Radio Interference Filter 120, 277 or 347 volt, 50 or 60 Hz. Suffix: R.

RCR 1 2

5" (127 mm)

0

24" (610 mm) 1000 60°

60°

2000

3 4 5 6 7 8 9 10

C. U. 65 58 52 47 42 37 34 30 27 25

3025

Black housing exterior for cooler ballast operating temperature

30°

30°

One piece-housing is embossed construction for added strength

Fully gasketed lens frame Turned-up edges for safe handling

Lens frame Symmetrical distribution jamb finished black for positive light stop

142

Asymmetrical distribution


Medical Luminaires

Electronic Ballast Input Watts (120V) Ballast Factor

Ordering Guide Lamps qty/type

176W .88

6-T8

SUS2GFSMA632 G TYPE ONLY

Basic catalogue number : SUS 632 Surgical Perimeter Static Luminaire

Exposed T-Grid SUS2GFSMA632

120 Voltage : 120 277 347

Flanged for dry or plaster SUS2FFSMA632

O6 Ballast : See page 142

Options : See page 142 Add appropriate suffix to catalogue number

The footcandle readings of a typical 8' x 12' pattern layout of 8, 6 lamp units, illustrates that the asymmetric distribution adds 35% more light to the operating area (room size 12' x 16' x 9' ceiling). Electronic Ballast Input Watts (120V) Ballast Factor

Ordering Guide Lamps qty/type

112W .88

4-T8

SUS2GFSMA432 Basic catalogue number :

Exposed T-Grid SUS2GFSMA432

120 Voltage :

Flanged for dry or plaster SUS2FFSMA432

O4 Ballast :

Options :

G TYPE ONLY

The footcandle readings of a typical 8' x 12' pattern layout of 8, 4 lamp units, illustrates that the asymmetric distribution adds 35% more light to the operating area (room size 12' x 16' x 9' ceiling).

143


Medical Luminaires

MDS 2’x 2’ Recessed Examination Light MDS2G36PS4FT120SB (Data)

MDS (2 x 2)

0

RCR

4-1/2" (114.3 mm) 24" (610 mm)

MEDICAL

Features •2 units provide 123 average footcandles on patient’s bed when installed over each end of bed. •Utilizes 2-2 lamp ballasts. •Utilizes 4-40 watt TT5 type lamps with excellent colour rendition (82 CRI). •3-1/2" x 3-1/2" cell size. •Door jamb with integral positive light stop. •Spring-loaded latches. •Integral earthquake clips. •Prismatic pattern 12 overlay to reduce glare and act as safety shield for broken glass. •Specular, semi-specular or white louver, 36 cells. Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SB. Magnetic Electronic PowerSpec Dimming 40W TT5: BX 40W TT5: SB 40W TT5: PB 50W TT5: BE (not avail. in 347V) 55W TT5: BF T12 not available. Fusing Internal fusing. Suffix: F. Radio Interference Filter 120, 277, 347 volt, 50 or 60 Hz. Suffix: R. Electrical/Wiring Options For special wiring, fusing, electronic dimming ballasts, consult factory. NOTE: For plaster or drywall ceiling: DRYWALL KIT, FK92X2.

144

1000 60° 2000

3736 0°

30°

C. U.

1 2

61 56

3 4

51 46

5 6

42 38

7 8

35 31

9 10

28 26


Medical Luminaires

Reference Data Efficiency Spacing Ratio

Ordering Guide Type Examination light shielding

55.9% 1.3

MDS 4 lamp 2' x 2' Recessed Examination Light

Electronic Ballast Input Watts (120V) Ballast Factor

136.0W .88

2 Luminaires

Wall

36 Cell 4-TT5 Low Iridescence Specular Louver with Prismatic Overlay 36 Cell 4-TT5 White Louver with Prismatic Overlay

MDS2G36PS4FT

Initial Footcandles on Bed 1 Luminaire

Lamp qty/type

Basic catalogue number : MDS Specular Louver

120 Voltage : 120 277 347

Catalogue number MDS2G36PS4FT

MDS2G36WS4FT

SB Ballast : See page 144

Options : See page 144 Add appropriate suffix to catalogue number

145


Medical Luminaires

OBL Series Over-bed, Wall Mounted OBL332120SO (Data)

OBL Overbedlight

6-1/16"" (154mm)

90°

1000 500

60° Pull Switch

500

5-9/16"" (141mm)

1000

Switching:

30°

4 Lamps = 1, 2, 3, 4 3 Lamps = 1, 2, 4 2 Lamps = 2, 4

MEDICAL

Features • For nursing homes, hospitals and other health care facilities. • Separate lamp compartments for controlled uplight and downlight. • Four-way pull switch, standard (120 volt only). • .125 thick DR acrylic linear prismatic refractor. (impact resistant). • Flat white fascia standard. • Cold rolled steel body with die-cast aluminum ends. • Concealed pull-action spring-loaded latches to retain lens. • Optional oak fascia insert.

RCR

C. U.

1 2

61 56

3 4

51 46

5 6

42 38

7 8

35 31

9 10

28 26

Request Folio R35-10 REV. A

Options page 150-156 Ballast Specify voltage (120 or 277) and type and add suffix (eg. 277SO). Electronic <10THD POWER SPEC DIMMING T8: SO T8: HI T8: PS Optional Fascia Insert Oak—to order substitute K for L in Catalog Number (i.e. OBL332 to OBK332). Radio Interference Filter 120 or 277 volt, 50 or 60 Hz. One per fixture standard. Suffix: R. Nite Light Consult factory.

Medical Luminaires

BED332120SO (Data)

BED Bedlight

BED 3’, 4’ Over-bed, Wall-mounted 180°

150°

600

K12 PRISMATIC LENS

300

0

120°

90°

300 60° 600

Features • For nursing homes, hospitals and other healthcare facilities. • Separate lamp compartments for controlled uplight and downlight. • Four-way pull switch optional (120 volt only). • Convenience outlet KO’s optional for left or right assembly. • 20 gauge steel body. • Acrylic pattern 12 refractors. • Semi-gloss, white acrylic baked enamel exterior finish standard. • Spotweld construction.

146

RCR 1 2 3 4 5 6 7 8 9 10

30°

Options pages 150-156 Ballast Specify voltage (120, 277 or 347) and add suffix, eg. 120SO. Magnetic Electronic T8: OC T8: SO For T12 see page 151. Radio Interference Filter 120, 277, 347 volt, 50 or 60 Hz. Suffix: R. Night Light† Incandescent, down section : NID ; up section NIU. Fluorescent, down section : NPD ; up section NPU. Pull Switch† : 2 way switch Left side : S2L, 4 way switch Left side : S4L, Right side : S2R or S4R. Convenience† Outlet : Left side COL, Right side COR. †Accessories, 120V only.

C. U. 61 56 51 46 42 38 35 31 28 26


Medical Luminaires

Ordering Guide Lamp Configuration

Fixture Length

Lamp Qty/Type

Catalog no.

2 Up/1 Down 2 Up/2 Down 1 Up/1 Down

48" 48" 48"

3-T8 4-T8 2-T8

OBL332 OBL432 OBL232

120

OBL332 Basic catalogue number : Overbed mounted luminaire

SO

Voltage : 120 277

R

Ballast : See page 146

Options : See page 146. Add appropriate suffixe to catalogue Number.

Reading Position 3’ (914.4 mm) SIDE VIEW

50 FC reading plane (60° from horizontal

6’ (1828.8 mm)

3’ 6” (1070mm) reading plane

Reading Position

Ordering Guide Lamp configuration

3’ (914.4 mm) SIDE VIEW

45 FC reading plane (60° from horizontal

6’ (1828.8 mm)

3’ 6” (1070mm) reading plane

1 Up/1 Down 2 Up/1 Down 2 Up/2 Down 1 Up/1 Down 2 Up/1 Down 2 Up/2 Down

BED332 Basic catalogue number :

Luminaire length

Lamp qty/type

37-3/16" 37-3/16" 37-3/16" 49-3/16" 49-3/16" 49-3/16"

2-T8 3-T8 4-T8 2-T8 3-T8 4-T8

120 Voltage :

Catalogue number BED225 BED325 BED425 BED232 BED332 BED432

SO Ballast :

Options :

Isolux Curve 3’ (914.4 mm) 4’ (1219.2 mm)

PLANE VIEW 30 FC downlight only

3’ (914.4 mm) 2’ (609 mm) 1’ (304.6 mm) 0 1’ (304.6 mm) 2’ (609 mm)

horizontal footcandles 3’ 6” (1070 mm) from floor up and down light down light only 3’ (914.4 mm)

4’ (1219.2 mm)

2’ (609 mm)

4’ (1219.2 mm)

1’ (304.6 mm)

3’ (914.4 mm)

147


Air Handling Data Air Return / Heat Transfer Data

2’ x 4’ size Deepcel, Parabaffle, Vision Smart

Heat removal through lamp compartment

Heat transfer (BTUH)

Heat transfer, energy distribution, three lamps — four lamps

NEGATIVE STATIC PRESSURE (IN. OF H2O)

All performance data on the 2’ x 4’ luminaire is based on a maintained room temperature of 75°F (24°C). Air performance tests were conducted in accordance with Air Diffusion Council (ADC) air diffusing troffer heat removal test code TC-66.

1. Heat removal through lamp compartment, two end entry 2. Return air through two side slots, direct exhaust 3. Combination heat removal / return air through lamp compartment and two side slots

1. Input, BTUH 2. Heat removed; BTUH 3. Heat to space; BTUH

Return air flow (CFM) Return air flow (CFM)

2’ x 2’ size Deepcel, Parabaffle, Vision Smart Heat transfer, energy distribution, two lamps

Heat transfer, energy distribution, two lamps

Heat transfer (BTUH)

NEGATIVE STATIC PRESSURE (IN. OF H2O)

All performance data on the 2’ x 2’ luminaire is based on a maintained room temperature of 75°F (24°C). Air performance tests were conducted in accordance with Air Diffusion Council (ADC) air diffusing troffer heat removal test code TC-66.

1. Input, BTUH 2. Heat removed; BTUH 3. Heat to space; BTUH

Return air flow (CFM)

148

Return air flow (CFM)


Technical Data Deepcel, Parabaffle, Paralyte

1’ x 4’ size Deepcel, VP / VR For prismalyte plus lens air data please consult your CFI Fluorescent representative.

Heat removal through lamp compartment

NEGATIVE STATIC PRESSURE (IN. OF H2O)

All performance data on the 1’ x 4’ luminaire is based on a maintained room temperature of 75°F (24°C). Air performance tests were conducted in accordance with Air Diffusion Council (ADC) air diffusing troffer heat removal test code TC-66. Heat transfer, energy distribution, two F40 lamps

Heat transfer (BTUH)

1. Input, BTUH 2. Heat removed; BTUH 3. Heat to space; BTUH

Return air flow (CFM)

Return air flow (CFM)

Standard grid or two directional concealed grid

100

20 air changes per hour at only .01 negative static pressure when mounted in 8’ x 10’ layout.

50

10 .001

.005 .010 .05 Negative Static Pressure (IN. of H2O)

.10

300 200

Slot grid or narrow grid

100

20 air changes per hour at only .008 negative static pressure when mounted in 8’ x 10’ layout.

50

10 .001

.005 .010 .05 Negative Static Pressure (IN. of H2O)

.10

Return air flow - Cubic feet per minute

300 200

PARALYTE 2 X 2 See pages 38-39

300 200

Standard grid or two directional concealed grid

100

Through the lamp compartment only.

Return air flow - Cubic feet per minute

Return air flow - Cubic feet per minute

Return air flow - Cubic feet per minute

PARALYTE 2 X 4 See pages 36-37

300 200

50

10 .001

.005 .010 .05 Negative Static Pressure (IN. of H2O)

.10

Slot grid or narrow grid

Through the lamp compartment and side slots.

100 50

10 .001

.005 .010 .05 Negative Static Pressure (IN. of H2O)

.10

149


Numbering System Logic Parabolic and Lens Troffer

note that this ordering guide lists all Parabolic Luminaire numbering logic. The possible combinations and options do not apply to Parabolic (Recessed and Surface) Please all luminaires. Please refer to the specific luminaire page.

DP Family

2

A Body Style

A: Air Supply Deepcel S: Static Paralyte B: Surface Box Parabaffle Vision Smart Preferred VR: Vision Smart Recommended AD, DX, DK, DZ, DV, DN: Vision Smart Preferred DD: Deepcel 20x60 ST: Stacklyte DP: PL: MP: VP:

G

Luminaire Width 1: 2: 5: 8:

12” 24” 20” 8”

18

Ceiling Type

Number of cells

G: Grid (lay-in T bar) T: Slot grid or twodirectional concealed T (see options)

8: 9: 10: 12:

16:

18: 24: 27: 29: 32: 36: 78:

Lens (Recessed and Surface) Except AA Troffer.

SP Family

2

S Body Style

A: Air Supply SP: SpecPlus S: Static PR: Prismalyte B: Surface Box Plus AAS: High Efficiency White Paint EL: Silverescent DS: 20” x 60” SQ: SpecTroffer DL: 500mm x 1200mm DM: 500mm x 1500mm DT: 20” x 48” SU: Operating Room Luminaire

Louver

finish 1x8 (1’x4’) 3x3 (2’x2’) L: Low 1x10 (1’x4’) iridescence Semi-specular 2x6 (2’x4’P: Low 20”x60”) iridescence 3x4 (2’x2’) Specular 1x12 (1 x4’) M: Matte low 4x4 (2’x2’) iridescence 1x16 (8”x48”12”x60”-12”x48”) 2x8 (1’x4’-20”x60”20”x48”) 3x6 (2’x4’-20”x48”-20”x60”) 2x12 (1’x4’) 3x8 (2’x4’) 3x9 (2’x4’) 2x9 (2’x4’-20”x48”-20”x60”) 2x16 (1’x4’-20”x60”) 4x8 (2’x4’) 6x6 (2’x2’) 6x13 (2’x4’)

G G: Grid (lay-in T bar) L: Self-Flange (T-Bar)

FS Lens Frame

3

Ballast cover louver mounting method

32

Lamp Lamp Type Quantity in a 17: T8 2’ luminaire 20: T12 2’ cross-section 32: T8 4’ 34: T12 4’ 1 2U:T8U1.6 2 6U:T8U6 or T12U6 3 FT: TT5 4 28: T5 linear 54: T5 linear 14: T5 linear 24: T5 linear

S: Standard P: Premium R: Specular reflector L: Lay-in louver

VA

4

Lens / shielding

Lamp Quantity in a luminaire cross-section

type FS: Flat steel frame VA (virgin acrylic) RA: Regressed standard (see aluminum options and frame consult factory FA: Flat page 155) aluminum frame LI: Lay in lens RF: Regressed aluminum floating door

Numbering system logic for AA Troffer see page

150

S

120

O3

Voltage

Ballast Type

120 See page 151. 277 347 UNV (120V/277V)

Options Add appropriate suffix to catalogue number

Please note that this ordering guide lists all Lens luminaire numbering logic. The possible combinations and options do not apply to all luminaires. Please refer to the specific luminaire page.

Luminaire Width Ceiling Type 1: 12” 2: 24” 5: 20”

L

54.

1 2 3 4 6

32

120

O4

Lamp Type

Voltage

Ballast Type

Options

17: 20: 32: 34: 2U: 6U: FT:

120 277 347

See page 151.

Add appropriate suffix to catalogue number

T8 2’ T12 2’ T8 4’ T12 4’ T8U1.6 T8U6 or T12U6 TT5


General Lamp and Ballast Logic

Lamp and ballast logic for all luminaires Except AA, Wal-Lyter, Walmaster, Ceiling-Lyter, Bi-Lyter, Impressions, TH, TT, TN, TX, CSW, Belmont Family, Lumiplex, SB, EE, FF, TU, VT, VTS, MD*4 and MD*Coffer.

2 Lamp Quantity in a luminaire cross-section 1 2 3 4 6

15: 17: 20: 25: 30: 32: 34: 48: 96: 2U: 6U: FT: 28: 54: 14: 24:

32

120

Lamp Type

Voltage

T12 18” T8 2’ T12 2’ T8 3’ T12 3’ T8 4’ T12 4’ 4’ SL, HO 8’ SL, HO T8U1.6 T8U6 or T12U6 TT5 linear TT5 linear TT5 linear TT5 linear TT5 linear

120 277 347 UNV (120V/277V)

Add appropriate suffix to catalogue number

T8 LW: ME: MX: M7: OC: O3: O4: O6: PS: RO: R3: R4: R6: SC: SO: R3: R4: SR:

BA: 18W Electronic TT5 RS BB: 24W Electronic TT5 RS BE: 50W Electronic TT5 RS BF: 55W Electronic TT5 RS BR: 40W Electronic TT5 RS BX: 40W Magnetic TT5 RS B3: 3 LPB Electronic TT5 RS IB: 40W Electronic TT5 IS I3: 3 LPB 40W Electronic TT5 IS MX: Electronic Mark X 40W TT5* M7: Electronic Dimming Mark VII 40W TT5* PA: 18W TT5 PowerSpec Dimming* PB: 40W TT5 PowerSpec Dimming* PC: 50/55W TT5 PowerSpec Dimming* SB: 40W Generic Electronic TT5 X3: 3 LPB 40W Electronic TT5 IS

PI: T5 Electronic IS PG: T5 Electronic PG

Options

Ballast Type

Ballast suffix applied to all luminaires

TT5

T5 Linear

SO

Electronic Low Watt IS Electronic Helios dimming T8* Electronic Mark X dimming T8* Electronic Mark VII dimming T8* Magnetic T8 3 LPB T8 Electronic IS, <20% THD 4 LPB T8 Electronic IS, <20% THD 2 ballasts O3, <20% THD PowerSpec Dimming T8* 1 or 2 LPB T8 Electronic RS, <10% THD 3 LPB T8 Electronic RS, <10% THD 4 LPB T8 Electronic RS, <10% THD 2 ballasts R3 Electronic Cold Start (0°F) IS 1 or 2 LPB T8 Electronic IS 3 LPB T8 Electronic RS, <20% THD 4 LPB T8 Electronic RS, <20% THD 1 or 2 LPB T8 Electronic RS, <20% THD

T12 SS: T12 Electronic

*Not available in 347 volt.

*Not available in 347 volt. LPB: IS: RS: PG:

Number of lamps per ballast Instant start Rapid start Program start

Lamp and ballast logic for : For AA, TH, TT, TN, TX, CSW, SB, EE, FF, TU,VT and VTS.

2

48

120

Lamp Quantity in a luminaire cross-section 1 2 3 4

Lamp Type

Voltage

18: 24: 36: 48: W8: 96: XXT: U6: U2: U4: XXH: XXS: XXHPF:

18” lamp 120 24” lamp 277 36” lamp 347 48” lamp 48” lamp wide body 96” lamp XX” lamp(s) in tandem configuration T8U6 T12U6 TT5 XX” lamp, High Output XX” lamp, Slimline XX” lamp, High Power Factor.

SO Ballast Type

Options Add appropriate suffix to catalogue number

151


Technical Lamp information Recessed Luminaire Options Lamp Wattage

QT Quad 4 pin 18

Lamp Manufacturer

Model # (add colour temperature desired in space ____)

Rated Life (hours)

Initial Lumens at 25°C

Colour Temperature (varies by lamp manufacturer) °K

CRI

GE PHILIPS OSRAM Sylvania

F18DBX/SPX ____/4P PL-C 18W/841/4P/ALTO CF18DD/E/8_____

10000 12000 10000

1250 1250 1250

3000, 3500, 4000 3000, 3500, 4100 3000, 3500, 4100

82 82 82

5.8” (147mm) 5 11/16” (144.5mm) 5.8” (147mm)

120, 277, 347 120, 277, 347 120, 277, 347

10000 12000 10000 10000 12000 10000

2400 2400 2400 3200 3200 3200

3000, 3500, 4000 3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100

82 82 82 82 82 82

5.8” (147mm) 5 5/8” (143mm) 5.6” (142mm) 6.4” (163mm) 6 3/8” (162mm) 6.4” (163mm)

120, 277, 347 120, 277, 347 120, 277, 347 120, 277, 347 120, 277, 347 120, 277, 347

10000 15000 20000 20000 15000 20000 12000 15000 12000 20000 20000 20000 14000 20000

1200 1250 1250 1250 1250 1250 1800 1800 1800 3150 3300 3150 4300 4300

3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100

82 82 82 82 82 82 82 82 82 82 82 82 82 82

9” (229mm) 8 15/16” (227mm) 10.5” (267mm) 10.5” (267mm) 8 15/16” (227mm) 10.5” (267mm) 12.9” (326mm) 12 11/16” (322mm) 12.9” (329mm) 22.5” (572mm) 22 1/2” (572mm) 22.6” (573mm) 22.5” (572mm) 22 1/2” (572mm)

120, 277, 347 120, 277, 347 120, 277, 347 120, 277, 347 120, 277, 347 120, 277, 347 120, 277, 347 120, 277, 347 120, 277, 347 120, 277, 347 120, 277, 347 120, 277, 347 120, 277, 347 120, 277, 347

12000

4800

3000, 3500, 4100

82

21.1”(535mm)

120, 277

TTT Triple Tube 4 pin GE F32TBX/SPX ____/A/4P PHILIPS PL-T 32W/841/4P/ALTO 32 OSRAM Sylvania CF32DT/E/IN/8_____ 42 GE F42TBX/SPX ___/A/4P PHILIPS PL-T 42W/841/4P/ALTO OSRAM Sylvania CF42DT/E/IN/8____ TT5 Preheat GE F18BX/SPX ____ PHILIPS PL-L 18W/841/4P ____ 18 OSRAM Sylvania FT18DL/8_____ Rapid GE F18BXSPX ____/RS Start PHILIPS PL-L18/ ____ OSRAM Sylvania FT18DL/8____/RS 18 Preheat GE F27/24BX/SPX ___ 24 PHILIPS PL-L 24W/841/4P ____ OSRAM Sylvania FT24DL/8____ Rapid GE F40/30BX/SPX ___ Start PHILIPS PL-L 40W/841/4P/RS/IS ____ 40 OSRAM Sylvania FT40DL/____/RS Rapid GE F50BX/SPX____/RS Start PHILIPS PL-L 50W/841/4P/RS 50 OSRAM Sylvania N/A Preheat GE N/A 55 PHILIPS N/A OSRAM Sylvania FT55DL/8____

Nominal Lamp Length inches (mm)

Electronic Ballast (volts) Availability *consult your representative on new ballast voltage availability

T8U6 32

OSRAM Sylvania PHILIPS GE

F32T8/SPX____/U/6 FB32T8/TL850/6 ALTO FB032/8____/6

20000 20000 20000

2800 2750 2850

3000, 3500, 4100 5000 3000, 3500, 4100

86 84 82

22.5” (572mm) 22 7/16” (570mm) 22.5” (572mm)

120, 277,347 120, 277,347 120, 277,347

OSRAM Sylvania PHILIPS GE

F31T8/SPX____/U N/A FB031/8____

20000

2725

3000, 3500, 4100

82

22.5” (572mm)

120, 277,347

20000

2725

3000, 3500, 4100

82

22.5” (572mm)

120, 277,347

LINEAR T8 17 OSRAM Sylvania PHILIPS GE 25 OSRAM Sylvania PHILIPS GE 32 OSRAM Sylvania PHILIPS GE

F17T8/SPX____ F17T8/TL841/ALTO FO17/8____ F25T8/SPX____ F25T8/TL841/ALTO FO25/8____ F32T8/SPX____ F32T8/TL841/ALTO____ FO32/8____

20000 20000 20000 20000 20000 20000 20000 20000 20000

1350 1400 1400 2150 2225 2150 2950 2950 3000

3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100

86 86 84 86 86 82 86 86 85

24” 24” (610mm) 24” (610mm) 36” 36” (914mm) 36” (914mm) 48” 48” (1220mm) 48” (1220mm)

120, 277,347 120, 277,347 120, 277,347 120, 277,347 120, 277,347 120, 277,347 120, 277,347 120, 277,347 120, 277,347

LINEAR T5 14 OSRAM Sylvania Stand. T5 PHILIPS GE 24 OSRAM Sylvania High PHILIPS Output T5 GE 28 OSRAM Sylvania Stand. T5 PHILIPS GE

FP14W/T5/8____ F14T5/841____ FP14/8____ F24W/T5/8____ F24T5/841/HO____ FP24/HO/8/____ F28W/T5/8____ F28T5/841____ FP28/8____

20000 20000 20000 20000 20000 20000 20000 20000 20000

1350 1350 1220 2000 2000 1760 2900 2900 2610

3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100

85 85 82 85 85 82 85 85 82

21.6” 22” (559mm) 22.2” (563mm) 33.4” 22” (559mm) 22.2” (563mm) 45.2” 46” (1163mm) 46” (1163mm)

120, 277, 347 120, 277,347 120, 277,347 120, 277, 347 120, 277,347 120, 277,347 120, 277, 347 120, 277,347 120, 277,347

54 OSRAM Sylvania High PHILIPS Output T5 GE

F54W/T5/8____ F54T5/841/HO/ALTO FP54/HO/8/____

20000 25000 20000

5000 5000 4400

3000, 3500, 4100 3000, 3500, 4100 3000, 3500, 4100

85 85 82

45.2” 46” (1163mm) 46” (1163mm)

120, 277, 347 120, 277,347 120, 277,347

6" T8U1.6 31

1-5/8"

LAMP CHART IS TO BE USED AS A GUIDE ONLY. CHECK LAMP/BALLAST MANUFACTURER DATA FOR EXACT SPECIFICATIONS.

152


Drywall Kit

“F” Mounting Frame Assembly 8" x 48", 20” x 48”, 1' x 4', 2' x 2', 2' x 4' For Mounting in Drywall or Ceilings Requiring Flanges 1/4” Dia. Wire Hanger Hole

1/8” Dia Screw Assembly Hole

1-3/8" (35mm)

Features • Designed to permit use of grid (NEMA G) luminaires in ceilings requiring flanges. • May be used with any G type (suspended grid ceiling with lay-in T-bar) or AA Series CFI Fluorescent troffer. • Extruded aluminum construction with mitered corners. • Includes screws for complete assembly.

3/16" (5mm)

15/16" (24mm)

49" (1245mm)

1-1/2" (38mm)

49" (1245mm)

26" (635mm)

“F” Mounting Frame Assembly Installation Instructions A) Single Luminaire Installation 10-1/4" (8"x48") or 13-1/8" (1'x4')

25" (635mm) A

B

- Includes screws for complete assembly - May be used for continuous row mounting using FK CRM (see ordering information matrix). - Not suitable for Paralyte Series (2 x 2, 2 x 4) and ADS8

B) Row Installation

Catalogue Number

Luminaire Size

FK908X4 FK920X4 FK91X4 FK91X4CRM FK92X4 FK92X4CRM FK92X2

8’’ x 48’’ 20’’ x 48’’ 1’ x 4’ 1’ x 4’ 2’ x 4’ 2’ x 4’ 2’ x 2’

Single Luminaire Ceiling Opening A B 9-3/4” (248mm) 48-5/8” (1235mm) 20-5/8 (524mm) 48-5/8” (1235mm) 12-5/8” (321mm) 48-5/8” (1235mm) X X 24-5/8” (626mm) 48-5/8” (1235mm) X X 24-5/8” (626mm) 24-5/8” (626mm)

Row Installation Ceiling Opening C D X X X X 12-5/8” (321mm)

D†

24-5/8” (626mm)

D†

X

X

D = 48-5/8’’ + [ (# of fixture - 1) x 48-3/16] OR D= 1235mm + [ (# of fixture - 1) x 1224mm] Example: Row of 3 luminaires: D = 48-5/8’’ + [(3-1) x 48-3/16] = 145” or 3683 mm †

Regular Mounting Frame

Mounting Frame for continuous row mounting (FK CRM)

- Includes screws for complete assembly - May be used for continuous row mounting using FK CRM (see ordering information matrix). - Not suitable for Paralyte Series (2 x 2, 2 x 4) and ADS8

Mounting Methods for “F” Mounting Frame Assembly. Note: Do not use wire hangers (by others) at end of luminaire.

Luminaire

Wire Hanger (by others)

Wire Hanger (by others) Luminaire “F” Mounting Frame Accoustical Tile (by others)

“F” Mounting Frame Plaster Frame Plaster (by others)

Luminaire

Wire Hanger (by others) “F” Mounting Frame Channel (by others) Accoustical Tile (by others)

153


Industrial Luminaire Options

Fusing

Reflector Row Aligners

Suffix F Internal fusing.

Tough, plastic aligners for luminaire reflectors. Catalogue Number: TU9RA - TU Series (shown) EE9RA - EE / FF Series

Radio Interference Filter

Twist Tee Hanger

Suffix R Inductive capacitor circuit designed to minimize interference from line radiation or feedback. 120, 277 or 347, 50 or 60 Hz. Example: TU248120SOR

For installation of 4-1/2" wide (channel) luminaire on exposed “T” grid ceilings or hard surfaces. Provides 1-1/2" clearance from surface. Catalogue Number: EE9H1 For luminaires: SB248 SB248T EE248 EE248T SB296S

Quick Connect Plug-In for Continuous Wireway Suffix CL3 - Single switching CL4 - Double switching

Stem and Canopy Sets Suspends luminaire 12”, 18”, 24”, 36”, 48” from surface and can be used in conjunction with Heavy Duty Slide Grip Hanger. Catalogue Number: STKF12 (12”), STKF18 (18”), STKF24 (24”), STKF36 (36”), STKF48 (48”).

Chain Hanger Kit Two 24” heavy duty link chains with sturdy “V” hooks that grip luminaires at four knockout points for level suspension. Catalogue Number: EE9HC (for SB, SV, EE, FF luminaires)

Canopy Spacer (1-1/2") Suspends luminaire approximately 1-1/2" from surface. Catalogue Number: STSK

Heavy Duty Slide-Grip Hanger

Wire Guards

Order Catalogue Number: EE9H3 For luminaires: EE248H EE248HT SB248H SB248HT TU248H TU248HT

Hinge and latch positive-lock construction, complete with longitudinal and transverse struts for secure protection. Cat. Number EE9G4 TU9G4 SB8G1-24 SB8G1-36 SB8G1-48 SB8G2-36 SB8G2-48 SB8G4-48 SV5GxG2 SV5GxG3 SV5GxG4

154

Luminaire EE/FF Series TU Series SB124 SB136 SB148, SB148T SB236 SB148H, SB148HT SB248, SB248T SB348, SB448 SV2S SV3S SV4S


Technical Information (industrial applications) Flat Lens and Louver Options COMPARISON BALLAST / LAMP DATA FOR INDUSTRIAL APPLICATIONS (8’) # of lamps

Lamp Type

Ballast type + quantity

System wattage

Lamp life

Lamp lumens

Lumens/ watt

Ballast suffix

2

T12 Slimline 8’

Magnetic instant start - 1 ballast

158

12,000

6100

67

LE

2

T12 Slimline 8’

Electronic instant start - 1 ballast

132

12,000

6100

92

SS

2

T12 H.O. 8’

Magnetic rapid start energy saving - 1 ballast

237

12,000

8800

74

LE

2

T8 - 8’

Electronic instant start - 1 ballast

110

15,000

6000

109

SO

4

T8 - 4’ Tandem

Magnetic rapid start - 2 ballasts

142

20,000

3050

86

OC

4

T8 - 4’ Tandem

Electronic instant start - 1 ballast

112

20,000

3050

109

O4

4

T8 - 4’ Tandem

Hybrid rapid start (Powerkut) - 2 ballasts

124

20,000

3050

98

OP

2

T8 - 8’

Electronic high output ballast - 1 ballast

174

15,000

6000

69

**

4

T8 - 4’ Tandem

1.28 ballast factor, ballast driving lamps at full rated wattage - 1 ballast

172

20,000

3050

70

**

2

T8 H.O. - 8’

Electronic ballast - 1 ballast

155

18,000

8200

91

SO

Figures are rated values not designed values. **Consult factory (actual lumens / watt are higher).

Recessed Luminaire Options

Fusing

Radio Interference Filter

Suffix : F Internal fusing.

R Inductive capacitor circuit designed to minimize interference from line radiation or feedback. 120V, 277V or 347V 50 or 60 Hz. One per luminaire standard. Example: DPA2G18LS33212003R

Lightolier PowerSpec Dimming Ballast

Prewiring FF6; FF14 3/8" factory prewired cable wired into luminaire. Configurations available in various wire gauges, numbers of wires and lengths up to 6'. Example: DPA2G18LS332120O3FF6 (3 #14 AWG leads, 6' long) DPA2G18LS332120O3FF14 (4 #14 AWG leads, 6' long)

For 40W TT5 (PB) or T8 (PS). See Catalogue Numbering System page 115. Example: DPS2G12LP232120PS

Energy Saving Tandem

Flex Wiring Systems

Radio Frequency Shielding

Factory prewired interconnection cable for plug-together installation of pairs of troffers. Designed to save energy by the elimination of 1 ballast. Consult factory.

All CFI Fluorescent troffers can be used with standard wiring systems available. Consult factory.

For hospitals, TV stations or wherever sensitive electronic equipment is in use. Consult factory.

Fluorescent Emergency Lighting System O Factory-installed emergency power battery pack with charger and inverter, B100 or equal, 120V, 277V or 347V (1 lamp, 90 min. at 15%) Example: SPS2GFSVA332120O3O Consult CFI Representative for specific products availability.

Recessed and Surface Troffer / Flat lens and Louver options For other available lenses and louvers, consult your CFI Fluorescent Representative. VA VB VY VK VX PY KA KS QA KK PA

Pattern 12 lens .095” nominal - Prismatic lens Pattern 12 lens .125” nominal - Prismatic lens Pattern 12 lens .130” ( .125” minimum) Pattern 12 lens .140” acrituff Pattern 12 lens .125” polycarbonate Pattern 12 lens .187” polycarbonate Pattern 19 lens .156” nominal - Prismatic lens Pattern 19 lens .156” nominal silver tint Pattern 20 lens .140” nominal Pattern 23 lens .100” Opal lens .080” nominal

PE PD PR EE CG AH HR HY DA AA AO

Opal lens .187” nominal Opal lens .125” nominal Pattern 49 lens .160” nominal with radio frequency interference filter lens KSH 3-E lens Pattern 73 tempered glass .150” (for RVS) Holophane 6150 molded 1 x 4 / 6250 molded 2 x 4 Holophane 8224 lens Holophane 8224 lens with frost overlay sealed Dropped Opal lens 1/2 x 1/2 x 1/2 white eggcrate acrylic 1/2 x 1/2 x 1/2 parabolic gold acrylic

AP BO BP GK SE SF SG UC SA XY

1/2 x 1/2 x 1/2 parabolic silver acrylic 1/2 x 1/2 x 1/2 parabolic gold styrene 1/2 x 1/2 x 1/2 parabolic silver styrene 3/4 x 3/4 x 1/2 parabolic gold acrylic 3/4 x 3/4 x 1/2 parabolic silver styrene 3/4 x 3/4 x 1/2 parabolic silver acrylic 3/4 x 3/4 x 1/2 parabolic gold styrene 3/4 x 3/4 x 3/4 parabolic aluminum 1 1/2 x 1 1/2 x 7/8 parabolic silver acrylic 2 x 2 x 1 3/8 parabolic aluminum (20”x 60” and 20” x 48”only)

155


Dimming Information

Dimming ballast selection and dimmers (see ballast suffix page ?? to order.) Ballast Selection

Lightolier PowerSpec HDF

Advance Mark X

Advance Mark VII

OSRAM Quicktronic

Linear T8

100 - 1 % 120 / 277 volts 100 - 10 % 120 / 277 volts 3 - Wire line voltage

100 - 5 % 120 / 277 volts 100 - 5 % 120 / 277 volts 2 - Wire line voltage

110 - 5 % 120 / 277 volts N/A

Osram / Sylvania Philips GE

Osram / Sylvania Philips GE

100 - 5 % 120 / 277 volts 100 - 5 % 120 / 277 volts 2 - Wire line voltage + 2 low voltage wires (0 - 10V) separate conduit Osram / Sylvania Philips GE

MS600HDF120 MH600HDF120 MH1500HDF120 all VA models* MSP600HDF120 MHP600HDF120 MHP1500HDF120 all VA models* ZP600HDF120 all VA models*

MS600EB MH600EB MH1000EB MH1500EB MSP600EB MHP600EB MHP1000EB

TT5 Wiring Lamp Mfr.

2 - Wire line voltage + 2 low voltage wires (0 - 10V) separate conduit Osram / Sylvania Philips GE

Compatible Dimmers MultiSet

MultiSet Pro

Sunrise Preset Momentum Preset Onset

Rockslide Preset Precision Rotary Insight Occupancy Sensor Lytemode

N/A

N/A

N/A

N/A

ZP600EB ZP1000EB

ZP600FAM120

ZP600FAM120

MP1500HDF120 all VA models* OS600HDF120 OH600HDF120 OH1500HDF120 all VA models* all VA models*

MP1500EB

MP1500FAM120

MP1500FAM120

OS600EB OS1000EB OH1500EB

N/A

N/A

N/A

N/A

N/A

all VA models*

N/A

N/A

N/A

all VA models*

N/A

N/A

N/A

LM2-2400HDF LM2-2400HDF-32 LM2-4000HDF LMDP-20HDF-120 LMDP-20HDF-277

N/A

LM2-2400FAM LM2-2400FAM-32 LM2-4000FAM

LM2-2400FAM LM2-2400FAM-32 LM2-4000FAM

* Use with DA10HDF, DA20HDF120l or DAHDF277l interfaces. ** Use with DA110ESI or DA210ESI interfaces.

PowerSpec ballast technical information T8 PowerSpec HDF Ballast HDF132T8UNV

Lamp Voltage Dimming range Input Wattage (max.) Line Current (amps) Input Wattage (min) Ballast Factor (full) Lamp CCF Power Factor (full) Power Factor (low) T.H.D. (@ 100% Lx) T.H.D. (@ 1% Lx) Min. Starting Temp. F

1x25W 120V 100-1% 28 2,3 9 >87% <1.6 >98% >97% <10% <10% 50

HDF232T8UNV

1x25W 277V 100-1% 29 0,1 10 >87% <1.6 >98% >97% <10% <20% 50

1x32W 120V 100-1% 36 0,3 9 >87% <1.6 >98% >97% <10% <10% 50

1x32W 277V 100-1% 37 1,3 10 >87% <1.6 >98% >97% <10% <20% 50

2x25W 120V 100-1% 54 0,46 12 >87% <1.6 >98% >97% <10% <10% 50

2x25W 277V 100-1% 54 0,2 13 >87% <1.6 >98% >97% <10% <20% 50

2x32W 120V 100-1% 68 0,57 13 >87% <1.6 >98% >97% <10% <10% 50

2x32W 277V 100-1% 68 0,25 15 >87% <1.6 >98% >97% <10% <20% 50

TT5 PowerSpec HDF Ballast HDF118T5120I HDF118T5277I HDF140T5120I HDF140T5277I HDF155120I

156

Lamp Voltage Dimming range Input Wattage (max.) Line Current (amps) Input Wattage (min) Ballast Factor (full) Lamp CCF Power Factor (full) Power Factor (low) T.H.D. (@ 100% Lx) T.H.D. (@ 1% Lx) Min. Starting Temp. F

1x18W 120V 100-10% 22 0,18 15 >90% <1.7 >95% >80% <13% <20% 50

1x18W 277V 100-10% 22 0,08 15 >90% <1.7 >95% >80% <13% <20% 50

1x40W 120V 100-10% 41 0,33 20 >90% <1.7 >95% >80% <13% <20% 50

1x40W 277V 100-10% 41 0,15 20 >90% <1.7 >95% >80% <13% <20% 50

1X55W 120V 100-10% 56 0,45 20 >90% <1.7 >95% >80% <13% <20% 50

HDF155277I HDF218T5120I HDF218277I HDF240T5120I HDF240T5277I

1X55W 277V 100-10% 56 0,2 20 >90% <1.7 >95% >80% <13% <20% 50

2x18W 120V 100-10% 39 0,32 20 >90% <1.7 >95% >80% <13% <20% 50

2x18W 277V 100-10% 39 0,14 20 >90% <1.7 >95% >80% <13% <20% 50

2X40W 120V 100-10% 75 0,61 25 >90% <1.7 >95% >80% <13% <20% 50

2X40W 277V 100-10% 75 0,27 25 >90% <1.7 >95% >80% <13% <20% 50


The Canlyte - Cornwall Location is Canada’s largest and most modern fluorescent lighting facility


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.