Solutions for the service sector (GB)

Page 105

øD

EC DA Outlet/loop return EF Cold water inlet EC hot water outlet

TT

DA

PI Support feet SF Flue gases outlet

TM

TH Manhole with an internal diameter

of 400 mm (or 500 mm depending on the power of the gas equipment)

TH H

TM Nozzles for thermometer TT Nozzles for thermostat (or PT100 VD DN50 drainage

E

F

G

M

J

K

L

probe)

DA

VD

Ø 1250 mm

A

PI

B

EF

SOLAR HOT WATER (DOMESTIC HOT WATER AND HEATING)

DIMENSIONS

2 Ø 800 and 1100 mm

270°

EC VM

EC VM

270°

DA

DA

DA EF TM TT

DA EF TM TT

SF

0° S

TH

S

SF

180°

180°

e .

n zo e k nc n ra ta ea Ø Cl =

n zo e k nc n ra ta ea Ø Cl =

TH

135°

e .

140°

90° V

TH

90°

TH

U

T

V U

45°

T

50°

With ø 400 mm manhole Capacity (litres) 1 000 1 500 2 000 2 500 3 000

A B (mm) (mm) 90 90 90 90 90

440 510 560 560 560

ØD (mm)

E (mm)

F (mm)

G (mm)

H (mm)

J (mm)

K (mm)

L (mm)

M (mm)

TG (G int. thread)

790 1 100 1 250 1 250 1 250

590 685 745 745 745

690 760 810 810 810

1 390 1 130 1 180 1 510 1 640

2 430 2 020 2 110 2 660 2 880

1 875 1 390 1 425 1 975 2 195

2 000 1 520 1 570 2 120 2 340

2 025 1 545 1 595 2 145 2 365

1 600 1 230 1 280 1 660 1 860

DN15 DN15 DN15 DN15 DN15

EC-EF (G int. thread) DA-VM (G ext. thread) DN50 DN50 DN50 DN50 DN50

Weight (kg)

155 225 265 335 355