FIBRE OPTIC CABLES

OM4 Multimode LOOSE TUBE

100m, 200m, 500m, CTL

OM4 50/125µm fibres are great for high-speed data transfer around and between buildings. With lower losses than OM3 fibre, OM4 is becoming the “go to” standard. OM4 fibre is backwards compatible with OM3 and can use the same connectors. Although more expensive, OM4 fibre is coming down in price as volumes increase. Stocked in armoured and unarmoured. OM4 Multimode 50/125µm Loose Tube Fibre Optic Unarmoured - U-DQ(ZN)BH CONSTRUCTION Single gel filled central tube surrounded by waterblocked E-Glass fibre elements, LSHF UV resistant sheath to IEC 50290-2-27. OPTICAL FIBRE TECHNICAL INFORMATION Fibre Type: G651.1, OM4 Optical Fibre EN 60793-2-10 type A1a.3 TIA/EIA-492 AAAD Standards: ANSI/TIA/EIA - 568.C EN 50173-1 category OM4 ISO / IEC 11801 category OM4 ITU G.651.1 ISO/IEC 24764 IEEE 802.3 Part No.

FOM404LUH00 FOM408LUH00 FOM412LUH00 FOM416LUH00 FOM424LUH00

FINISHED CABLE TECHNICAL INFORMATION Standards: ISO 11801 2nd Edition EN 50173-1-2002 IEC 60794-1 Temperature Rating: Flexing -30°C to +40°C Static -30°C to +60°C Minimum Bend Radius: Unloaded 60mm Loaded 100mm Flame Retardant: IEC/BS EN 60332-1-2 Smoke Emission: IEC/BS EN 61034-2 Halogen Emission: IEC/BS EN 60754-1&2

No. of Fibres

Sheath Material

Sheath Colour

Weight kg/km

O/D mm

4 8 12 16 24

LSHF LSHF LSHF LSHF LSHF

Black Black Black Black Black

40 40 40 40 45

6.0 6.0 6.0 6.0 6.5

OM4 Multimode 50/125µm Loose Tube Fibre Optic Armoured - U-DQ(ZN)(SR)H CONSTRUCTION Single gel filled central tube surrounded by water-blocked E-Glass fibre elements, corrugated steel tape armour, LSHF UV resistant sheath to IEC 50290-2-27. OPTICAL FIBRE TECHNICAL INFORMATION Fibre Type: G651.1, OM4 Optical Fibre EN 60793-2-10 type A1a.3 TIA/EIA-492 AAAD Standards: ANSI/TIA/EIA - 568.C EN 50173-1 category OM4 ISO / IEC 11801 category OM4 ITU G.651.1 ISO/IEC 24764 IEEE 802.3 Part No.

FOM404LUHC00 FOM408LUHC00 FOM412LUHC00 FOM416LUHC00 FOM424LUHC00

Low Smoke Halogen Free

FINISHED CABLE TECHNICAL INFORMATION Standards: ISO 11801 2nd Edition EN 50173-1-2002 IEC 60794-1 Temperature Rating: Flexing -40°C to +70°C Static -40°C to +70°C Minimum Bend Radius: 55mm Flame Retardant: Smoke Emission: Halogen Emission:

IEC/BS EN 60332-1-2 IEC/BS EN 61034-2 IEC/BS EN 60754-1&2

No. of Fibres

Armour

Sheath Material

Sheath Colour

Weight kg/km

O/D mm

4 8 12 16 24

CST CST CST CST CST

LSHF LSHF LSHF LSHF LSHF

Black Black Black Black Black

75 75 75 75 85

8.5 8.5 8.5 8.5 8.5

Armoured

CPR-Compliant Options Available