Antennax Brochure

Page 1

Antennax Ultra Low-Loss Coaxial Cables Designed for LMR, VSAT and Communication


Why Antennax™ should be your cable of choice

Antennax

The cable that won’t let you down Antennax™ cables are sweep tested to 5.8 GHz to ensure outstanding performance across the operating spectrum, providing a high quality alternative to Times Microwave Systems LMR® and the Andrew Cinta® range. Next working day despatch worldwide Antennax™ cables provide ultra-low loss performance from transceiver to aerial or dish. Developed for Land Mobile Radio (LMR), microwave, satellite, VSAT and communications, these cables are manufactured to ensure optimum levels of performance. 50Ω and 75Ω versions are stocked on 1km drums and can be cut to your requirement for immediate worldwide despatch. Manufactured to internationally recognised standards The Low Smoke Halogen Free (LSHF) versions conform to European fire safety standards and are flame retardant making them the ideal choice for use on rigs, ships, in tunnels or public buildings where fire safety is a concern. The UV stabilised sheath allows for cables to be run outside or inside avoiding the need for cable joints that increase signal loss and add costs. For the perfect installation, a wide range of connectivity options are available including N-Type, TNC, BNC, and F-Type, SMA, Right Angle and Reverse Polarity connectors and termination tools. Call, email or contact us now to find out how Antennax™ can benefit you.

2


Contents Page What you need to know about Antennax™

2

Antennax™ ANT-195 50 Ohm PE

4

Antennax™ ANT-195H 50 Ohm LSHF

6

Antennax™ ANT-200 50 Ohm PE

8

Antennax™ ANT-200H 50 Ohm LSHF

10

Antennax™ ANT-240 50 Ohm PE

12

Antennax™ ANT-240 50 Ohm LSHF

14

Antennax™ ANT-300 50 Ohm PE

16

Antennax™ ANT-300H 50 Ohm LSHF

18

Antennax™ ANT-400 50 Ohm PE

20

Antennax™ ANT-400H 50 Ohm LSHF

22

Antennax™ ANT-400H 75 Ohm LSHF

24

Antennax™ ANT-600 50 Ohm PE

26

Antennax™ ANT-600H 50 Ohm LSHF

28

Antennax™ ANT-600H 75 Ohm LSHF

30

3


Antennax™ ANT-195 50 Ohm PE Part No: Description:

390L19 ANT-195 50 Ohm Antennax™ Feeder Cable Black PE

Antennax Construction Conductor Material Stranding Dielectric Diameter of Dielectric Screen Material (1) Coverage (1) Screen Material (2) Coverage (2) Outer Sheath Material Outer Sheath Colour

Solid Bare Copper 1/0.94 mm Foamed Polyethylene (FPE) 2.79 mm Bonded Aluminium Tape 100% Tinned Copper Wire Braid > 89% Polyethylene – UV Resistant Black

Electrical Characteristics Impedance Capacitance Velocity of Propagation Conductor Resistance Outer Conductor Resistance Voltage Withstand Jacket Spark Return Loss (30-2800MHz) Peak Power

50 Ω 24.3 pF/ft (79.7 pF/m) 75% ≤ 24.9 Ω/km ≤ 16.1 Ω/km 1.5 kV 3.0 kV (rms) ≥ 15 dB 2.5 kW

Physical Characteristics Overall Diameter Min. Bend Radius Temperature Rating Weight

5.0 mm 12.7 mm -30°C to +85°C 30 kg/km

Standards RoHS2 Compliant

4

Yes


ANT-195

Attenuation

Cable Cross Reference Chart

Frequency Attenuation (MHz) dB/100ft dB/100m

Antennax™ Times Microwave Andrew® ANT-195 LMR-195 CNT-195

30 50 150 220 450 900 1500 1800 2000 2500

2.1 2.6 4.3 5.2 7.5 10.9 14.2 15.7 16.6 19.5

6.8 8.6 14.2 17.0 24.7 35.6 46.7 51.5 54.3 63.8

These are actual test results from production cable. They should not be confused with the theoretical data shown in some companies catalogues.

Complete range of connectivity available

BNC Male

Attenuation performance independently verified by Telegärtner UK Ltd

5


Antennax™ ANT-195H 50 Ohm LSHF Part No: Description:

390L19H ANT-195H 50 Ohm Antennax™ Feeder Cable Black LSHF

Antennax Construction Conductor Material Stranding Dielectric Diameter of Dielectric Screen Material (1) Coverage (1) Screen Material (2) Coverage (2) Outer Sheath Material Outer Sheath Colour

Solid Bare Copper 1/0.94 mm Foamed Polyethylene (FPE) 2.79 mm Bonded Aluminium Tape 100% Tinned Copper Wire Braid > 89% Low Smoke Halogen Free, UV Resistant Black

Electrical Characteristics Impedance Capacitance Velocity of Propagation Conductor Resistance Outer Conductor Resistance Voltage Withstand Jacket Spark Return Loss (30-2800MHz) Peak Power

50 Ω 24.3 pF/ft (79.7 pF/m) 75% ≤ 24.9 Ω/km ≤ 16.1 Ω/km 1.5 kV 3.0 kV (rms) ≥ 15 dB 2.5 kW

Physical Characteristics Overall Diameter Min. Bend Radius Temperature Rating Weight

5.0 mm 12.7 mm -35°C to +80°C 30 kg/km

Standards RoHS2 Compliant Low Smoke Generation Halogen Gas Emission Flame Retardant

6

Yes IEC 61034-2 IEC 60754-1&2 IEC 60332-1-2


ANT-195H

Attenuation

Cable Cross Reference Chart

Frequency Attenuation (MHz) dB/100ft dB/100m

Antennax™ Times Microwave Andrew® ANT-195H LMR-195-FR CNT-195-FR

30 50 150 220 450 900 1500 1800 2000 2500

2.1 2.6 4.3 5.2 7.5 10.9 14.2 15.7 16.6 19.5

6.8 8.6 14.2 17.0 24.7 35.6 46.7 51.5 54.3 63.8

These are actual test results from production cable. They should not be confused with the theoretical data shown in some companies catalogues.

Complete range of connectivity available

N-Type Female

Attenuation performance independently verified by Telegärtner UK Ltd

7


Antennax™ ANT-200 50 Ohm PE Part No: Description:

390L20 ANT-200 50 Ohm Antennax™ Feeder Cable Black PE

Antennax Construction Conductor Material Stranding Dielectric Diameter of Dielectric Screen Material (1) Coverage (1) Screen Material (2) Coverage (2) Outer Sheath Material Outer Sheath Colour

Solid Bare Copper 1/1.12 mm Foamed Polyethylene (FPE) 2.95 mm Bonded Aluminium Tape 100% Tinned Copper Wire Braid > 88% Polyethylene, UV Resistant Black

Electrical Characteristics Impedance Velocity of Propagation Capacitance Withstand Voltage Jacket Spark Conductor Resistance Outer Conductor Resistance Return Loss (30-2800MHz) Peak Power

50 Ω 83% 24.5 pF/ft (80.4 pF/m) 1.5 kV 3.0 kV (rms) ≤ 17.6 Ω/km ≤ 16.1 Ω/km ≥ 15 dB 2.5 kW

Physical Characteristics Overall Diameter Min. Bend Radius Temperature Rating Weight

5.0 mm 12.7 mm -30°C to +85°C 30 kg/km

Standards RoHS2 Compliant

8

Yes


ANT-200

Attenuation

Cable Cross Reference Chart

Frequency Attenuation (MHz) dB/100ft dB/100m

Antennax™ Times Microwave Andrew® ANT-200 LMR-200 Not available

30 50 150 220 450 900 1500 1800 2000 2500

1.9 2.3 3.7 4.5 6.5 9.5 12.5 13.8 14.6 16.6

6.1 7.5 12.1 14.6 21.3 31.1 40.9 45.1 47.8 54.2

These are actual test results from production cable. They should not be confused with the theoretical data shown in some companies catalogues.

Complete range of connectivity available

N-Type Male

Attenuation performance independently verified by Telegärtner UK Ltd

9


Antennax™ ANT-200H 50 Ohm LSHF Part No: Description:

390L20H ANT-200H 50 Ohm Antennax™ Feeder Cable Black LSHF

Antennax Construction Conductor Material Stranding Dielectric Diameter of Dielectric Screen Material (1) Coverage (1) Screen Material (2) Coverage (2) Outer Sheath Material Outer Sheath Colour

Solid Bare Copper 1/1.12 mm Foamed Polyethylene (FPE) 2.95 mm Bonded Aluminium Tape 100% Tinned Copper Wire Braid > 88% Low Smoke Halogen Free, UV Resistant Black

Electrical Characteristics Impedance Velocity of Propagation Capacitance Withstand Voltage Jacket Spark Conductor Resistance Outer Conductor Resistance Return Loss (30-2800MHz) Peak Power

50 Ω 83% 24.5 pF/ft (80.4 pF/m) 1.5 kV 3.0 kV (rms) ≤ 17.6 Ω/km ≤ 16.1 Ω/km ≥ 15 dB 2.5 kW

Physical Characteristics Overall Diameter Min. Bend Radius Temperature Rating Weight

5.0 mm 12.7 mm -35°C to +80°C 30 kg/km

Standards RoHS2 Compliant Low Smoke Generation Halogen Gas Emission Flame Retardant

10

Yes IEC 61034-2 IEC 60754-1&2 IEC 60332-1-2


ANT-200H

Attenuation

Cable Cross Reference Chart

Frequency Attenuation (MHz) dB/100ft dB/100m

Antennax™ Times Microwave Andrew® ANT-200H LMR-200-FR Not available

30 50 150 220 450 900 1500 1800 2000 2500

1.9 2.3 3.7 4.5 6.5 9.5 12.5 13.8 14.6 16.6

6.1 7.5 12.1 14.6 21.3 31.1 40.9 45.1 47.8 54.2

These are actual test results from production cable. They should not be confused with the theoretical data shown in some companies catalogues.

Complete range of connectivity available

TNC Female

Attenuation performance independently verified by Telegärtner UK Ltd

11


Antennax™ ANT-240 50 Ohm PE Part No: Description:

390L24 ANT-240 50 Ohm Antennax™ Feeder Cable Black PE

Antennax Construction Conductor Material Stranding Dielectric Diameter of Dielectric Screen Material (1) Coverage (1) Screen Material (2) Coverage (2) Outer Sheath Material Outer Sheath Colour

Solid Bare Copper 1/1.42 mm Foamed Polyethylene (FPE) 3.81 mm Bonded Aluminium Tape 100% Tinned Copper Wire Braid > 90% Polyethylene, UV Resistant Black

Electrical Characteristics Impedance Velocity of Propagation Capacitance Voltage Withstand Jacket Spark Conductor Resistance Outer Conductor Resistance Return Loss (30-2800MHz) Peak Power

50 Ω 83% 24.4 pF/ft (80.0 pF/m) 1.5 kV 5.0 kV (rms) ≤ 10.9 Ω/km ≤ 12.8 Ω/km ≥ 15 dB 5.6 kW

Physical Characteristics Overall Diameter Min. Bend Radius Temperature Rating Weight

6.1 mm 19.1 mm -30°C to +85°C 50 kg/km

Standards RoHS2 Compliant

12

Yes


ANT-240

Attenuation

Cable Cross Reference Chart

Frequency Attenuation (MHz) dB/100ft dB/100m

Antennax™ Times Microwave Andrew® ANT-240 LMR-240 CNT-240

30 50 150 220 450 900 1500 1800 2000 2500 5800

1.5 1.8 2.9 3.5 5.1 7.4 9.7 10.7 11.3 12.7 20.0

4.9 6.0 9.6 11.5 16.8 24.3 31.8 35.0 37.0 41.8 65.5

These are actual test results from production cable. They should not be confused with the theoretical data shown in some companies catalogues.

Complete range of connectivity available

TNC Male

Attenuation performance independently verified by Telegärtner UK Ltd

13


Antennax™ ANT-240 50 Ohm LSHF Part No: Description:

390L24H ANT-240H 50 Ohm Antennax™ Feeder Cable Black LSHF

Antennax Construction Conductor Material Stranding Dielectric Diameter of Dielectric Screen Material (1) Coverage (1) Screen Material (2) Coverage (2) Outer Sheath Material Outer Sheath Colour

Solid Bare Copper 1/1.42 mm Foamed Polyethylene (FPE) 3.81 mm Bonded Aluminium Tape 100% Tinned Copper Wire Braid > 90% Low Smoke Halogen Free, UV Resistant Black

Electrical Characteristics Impedance Velocity of Propagation Capacitance Voltage Withstand Jacket Spark Conductor Resistance Outer Conductor Resistance Return Loss (30-2800MHz) Peak Power

50 Ω 83% 24.4 pF/ft (80.0 pF/m) 1.5 kV 5.0 kV (rms) ≤ 10.9 Ω/km ≤ 12.8 Ω/km ≥ 15 dB 5.6 kW

Physical Characteristics Overall Diameter Min. Bend Radius Temperature Rating Weight

6.1 mm 19.1 mm -35°C to +80°C 50 kg/km

Standards RoHS2 Compliant Low Smoke Generation Halogen Gas Emission Flame Retardant

14

Yes IEC 61034-2 IEC 60754-1&2 IEC 60332-1-2


ANT-240H

Attenuation

Cable Cross Reference Chart

Frequency Attenuation (MHz) dB/100ft dB/100m

Antennax™ Times Microwave Andrew® ANT-240H LMR-240-FR CNT-240-FR

30 50 150 220 450 900 1500 1800 2000 2500 5800

1.5 1.8 2.9 3.5 5.1 7.4 9.7 10.7 11.3 12.7 20.0

4.9 6.0 9.6 11.5 16.8 24.3 31.8 35.0 37.0 41.8 65.5

These are actual test results from production cable. They should not be confused with the theoretical data shown in some companies catalogues.

Complete range of connectivity available

TNC Reverse Polarity Female (Spring Finger)

Attenuation performance independently verified by Telegärtner UK Ltd

15


Antennax™ ANT-300 50 Ohm PE Part No: Description:

390L30 ANT-300 50 Ohm Antennax™ Feeder Cable Black PE

Antennax Construction Conductor Material Stranding Dielectric Diameter of Dielectric Screen Material (1) Coverage (1) Screen Material (2) Coverage (2) Outer Sheath Material Outer Sheath Colour

Solid Bare Copper 1/1.78 mm Foamed Polyethylene (FPE) 4.83 mm Bonded Aluminium/Polyester/Aluminium Tape 100% Tinned Copper Wire Braid > 87% Polyethylene, UV Resistant Black

Electrical Characteristics Impedance Velocity of Propagation Capacitance Voltage Withstand Jacket Spark Conductor Resistance Outer Conductor Resistance Return Loss (30-2800MHz) Peak Power

50 Ω 83% 24.5 pF/ft (80.4 pF/m) 2.5 kV 5.0 kV (rms) ≤ 7.0 Ω/km ≤ 7.7 Ω/km ≥ 15 dB 10.0kW

Physical Characteristics Overall Diameter Min. Bend Radius Temperature Rating Weight

7.6 mm 22.2 mm -30°C to +85°C 80 kg/km

Standards RoHS2 Compliant

16

Yes


ANT-300

Attenuation

Cable Cross Reference Chart

Frequency Attenuation (MHz) dB/100ft dB/100m

Antennax™ Times Microwave Andrew® ANT-300 LMR-300 CNT-300

30 50 150 220 450 900 1500 1800 2000 2500 5800

1.2 1.4 2.3 2.8 4.1 6.0 7.8 8.6 9.1 10.3 16.6

3.8 4.7 7.6 9.2 13.5 19.6 25.7 28.3 30.0 33.8 54.3

These are actual test results from production cable. They should not be confused with the theoretical data shown in some companies catalogues.

Complete range of connectivity available

N-Type Female

Attenuation performance independently verified by Telegärtner UK Ltd

17


Antennax™ ANT-300H 50 Ohm LSHF Part No: Description:

390L30H ANT-300H 50 Ohm Antennax™ Feeder Cable Black LSHF

Antennax Construction Conductor Material Stranding Dielectric Diameter of Dielectric Screen Material (1) Coverage (1) Screen Material (2) Coverage (2) Outer Sheath Material Outer Sheath Colour

Solid Bare Copper 1/1.78 mm Foamed Polyethylene (FPE) 4.83 mm Bonded Aluminium/Polyester/Aluminium Tape 100% Tinned Copper Wire Braid > 87% Low Smoke Halogen Free, UV Resistant Black

Electrical Characteristics Impedance Velocity of Propagation Capacitance Voltage Withstand Jacket Spark Conductor Resistance Outer Conductor Resistance Return Loss (30-2800MHz) Peak Power

50 Ω 83% 24.5 pF/ft (80.4 pF/m) 2.5kV 5.0kV (rms) ≤ 7.0 Ω/km ≤ 7.7 Ω/km ≥ 15 dB 10.0kW

Physical Characteristics Overall Diameter Min. Bend Radius Temperature Rating Weight

7.6 mm 22.2 mm -35°C to +80°C 80 kg/km

Standards RoHS2 Compliant Low Smoke Generation Halogen Gas Emission Flame Retardant

18

Yes IEC 61034-2 IEC 60754-1&2 IEC 60332-1-2


ANT-300H

Attenuation

Cable Cross Reference Chart

Frequency Attenuation (MHz) dB/100ft dB/100m

Antennax™ Times Microwave Andrew® ANT-300H LMR-300-FR CNT-300-FR

30 50 150 220 450 900 1500 1800 2000 2500 5800

1.2 1.4 2.3 2.8 4.1 6.0 7.8 8.6 9.1 10.3 16.6

3.8 4.7 7.6 9.2 13.5 19.6 25.7 28.3 30.0 33.8 54.3

These are actual test results from production cable. They should not be confused with the theoretical data shown in some companies catalogues.

Complete range of connectivity available

N-Type Male

Attenuation performance independently verified by Telegärtner UK Ltd

19


Antennax™ ANT-400 50 Ohm PE Part No: Description:

390L40 ANT-400 50 Ohm Antennax™ Feeder Cable Black PE

Antennax Construction Conductor Material Stranding Dielectric Diameter of Dielectric Screen Material (1) Coverage (1) Screen Material (2) Coverage (2) Outer Sheath Material Outer Sheath Colour

Copper Clad Aluminium 1/2.74 mm Foamed Polyethylene (FPE) 7.24 mm Bonded Aluminium/Polyester/Aluminium Tape 100% Tinned Copper Wire Braid 86% Polyethylene, UV Resistant Black

Electrical Characteristics Impedance Velocity of Propagation Withstand Voltage Jacket Spark Capacitance Conductor Resistance Outer Conductor Resistance Return Loss (30-2800MHz) Peak Power

50 Ω 85% 2.5 kV 8.0 kV (rms) 24 pF/ft (78.7 pF/m) ≤ 4.6 Ω/km ≤ 5.4 Ω/km ≥ 15 dB 16.0 kW

Physical Characteristics Overall Diameter Min. Bend Radius Temperature Rating Weight

10.3 mm 24.5 mm -30°C to +85°C 100 kg/km

Standards RoHS2 Compliant

20

Yes


ANT-400

Attenuation

Cable Cross Reference Chart

Frequency Attenuation (MHz) dB/100ft dB/100m

Antennax™ Times Microwave Andrew® ANT-400 LMR-400 CNT-400

30 50 150 220 450 900 1500 1800 2000 2500 5800

0.8 1.0 1.5 1.9 2.7 3.9 5.1 5.6 5.9 6.7 11.2

2.5 3.2 4.9 6.2 8.8 12.8 16.7 18.3 19.3 21.9 36.5

These are actual test results from production cable. They should not be confused with the theoretical data shown in some companies catalogues.

Complete range of connectivity available

TNC Reverse Polarity Male (Spring Finger)

Attenuation performance independently verified by Telegärtner UK Ltd

21


Antennax™ ANT-400H 50 Ohm LSHF Part No: Description:

390L40H ANT-400H 50 Ohm Antennax™ Feeder Cable Black LSHF

Antennax Construction Conductor Material Stranding Dielectric Diameter of Dielectric Screen Material (1) Coverage (1) Screen Material (2) Coverage (2) Outer Sheath Material Outer Sheath Colour

Copper Clad Aluminium 1/2.74 mm Foamed Polyethylene (FPE) 7.24 mm Bonded Aluminium/Polyester/Aluminium Tape 100% Tinned Copper Wire Braid 86% Low Smoke Halogen Free, UV Resistant Black

Electrical Characteristics Impedance Velocity of Propagation Withstand Voltage Jacket Spark Capacitance Conductor Resistance Outer Conductor Resistance Return Loss (30-2800MHz) Peak Power

50 Ω 85% 2.5 kV 8.0 kV (rms) 24 pF/ft (78.7 pF/m) ≤ 4.6 Ω/km ≤ 5.4 Ω/km ≥ 15 dB 16.0 kW

Physical Characteristics Overall Diameter Min. Bend Radius Temperature Rating Weight

10.3 mm 24.5 mm -35°C to +80°C 100 kg/km

Standards RoHS2 Compliant Yes Low Smoke Generation IEC 61034-2 Halogen Gas Emission IEC 60754-1&2 Flame Retardant IEC 60332-1-2, 60332-3-24 Cat C

22


ANT-400H

Attenuation

Cable Cross Reference Chart

Frequency Attenuation (MHz) dB/100ft dB/100m

Antennax™ Times Microwave Andrew® ANT-400H LMR-400-FR CNT-400-FR

30 50 150 220 450 900 1500 1800 2000 2500 5800

0.8 1.0 1.5 1.9 2.7 3.9 5.1 5.6 5.9 6.7 11.2

2.5 3.2 4.9 6.2 8.8 12.8 16.7 18.3 19.3 21.9 36.5

These are actual test results from production cable. They should not be confused with the theoretical data shown in some companies catalogues.

Complete range of connectivity available

TNC Reverse Polarity Female (Spring Finger)

Attenuation performance independently verified by Telegärtner UK Ltd

23


Antennax™ ANT-400H 75 Ohm LSHF Part No: Description:

390L40H-75 ANT-400H 75 Ohm Antennax™ Feeder Cable Black LSHF

Antennax Construction Conductor Material Stranding Dielectric Diameter of Dielectric Screen Material (1) Coverage (1) Screen Material (2) Coverage (2) Outer Sheath Material Outer Sheath Colour

Solid Bare Copper 1/1.65 mm Foamed Polyethylene (FPE) 7.24 mm Bonded Aluminium/Polyester/Aluminium Tape 100% Tinned Copper Wire Braid > 86% Low Smoke Halogen Free, UV Resistant Black

Electrical Characteristics Impedance Velocity of Propagation Capacitance Voltage Withstand Jacket Spark Conductor Resistance Outer Conductor Resistance Return Loss ( 30-1000MHz) (1001-2200MHz) (2201-2500MHz) Peak Power

75 Ω 85% 15.9 pF/ft (52.2 pF/m) 2.0 kV 8.0 kV (rms) ≤ 8.2 Ω/km ≤ 5.5 Ω/km ≥ 22 dB ≥ 20 dB ≥ 15 dB 10 kW

Physical Characteristics Overall Diameter Min. Bend Radius Temperature Rating Weight

10.3 mm 24.5 mm -35°C to +80°C 100 kg/km

Standards RoHS2 Compliant Yes Low Smoke Generation IEC 61034-2 Halogen Gas Emission IEC 60754-1&2 Flame Retardant IEC 60332-1-2, 60332-3-24 Cat C

24


ANT-400H-75

Attenuation

Cable Cross Reference Chart

Frequency Attenuation (MHz) dB/100ft dB/100m

Antennax™ Times Microwave Andrew® ANT-400H-75 Not available Not available

30 50 150 220 450 900 1500 1800 2000 2500

0.7 0.9 1.5 1.8 2.6 3.8 5.0 5.5 5.6 6.6

2.3 2.9 4.8 5.8 8.5 12.3 16.3 18.0 18.5 21.5

These are actual test results from production cable. They should not be confused with the theoretical data shown in some companies catalogues.

Complete range of connectivity available

N-Type Male

Attenuation performance independently verified by Telegärtner UK Ltd

25


Antennax™ ANT-600 50 Ohm PE Part No: Description:

390L60 ANT-600 50 Ohm Antennax™ Feeder Cable Black PE

Antennax Construction Conductor Material Stranding Dielectric Diameter of Dielectric Screen Material (1) Coverage (1) Screen Material (2) Coverage (2) Outer Sheath Material Outer Sheath Colour

Copper Clad Aluminium 1/4.47 mm Foamed Polyethylene (FPE) 11.56 mm Bonded Aluminium/Polyester/Aluminium Tape 100% Tinned Copper Wire Braid > 90% Polyethylene, UV Resistant Black

Electrical Characteristics Impedance Velocity of Propagation Capacitance Voltage Withstand Jacket Spark Conductor Resistance Outer Conductor Resistance Return Loss (30-2800MHz) Peak Power

50 Ω 85% 23.2 pF/ft (76.1 pF/m) 4.6 kV 8.0 kV (rms) ≤ 1.7 Ω/km ≤ 5.7 Ω/km ≥ 15 dB 40.0 kW

Physical Characteristics Overall Diameter Min. Bend Radius Temperature Rating Weight

15.0 mm 38.1 mm -40°C to +85°C 200 kg/km

Standards RoHS2 Compliant

26

Yes


ANT-600

Attenuation

Cable Cross Reference Chart

Frequency Attenuation (MHz) dB/100ft dB/100m

Antennax™ Times Microwave Andrew® ANT-600 LMR-600 CNT-600

30 50 150 220 450 900 1500 1800 2000 2500 5800

0.5 0.6 1.0 1.2 1.7 2.5 3.3 3.7 3.9 4.4 7.2

1.6 2.0 3.2 3.8 5.6 8.2 10.8 12.0 12.7 14.5 23.6

These are actual test results from production cable. They should not be confused with the theoretical data shown in some companies catalogues.

Complete range of connectivity available

TNC Reverse Polarity Male (Spring Finger)

Attenuation performance independently verified by Telegärtner UK Ltd

27


Antennax™ ANT-600H 50 Ohm LSHF Part No: Description:

390L60H ANT-600H 50 Ohm Antennax™ Feeder Cable Black LSHF

Antennax Construction Conductor Material Stranding Dielectric Diameter of Dielectric Screen Material (1) Coverage (1) Screen Material (2) Coverage (2) Outer Sheath Material Outer Sheath Colour

Copper Clad Aluminium 1/4.47 mm Foamed Polyethylene (FPE) 11.56 mm Bonded Aluminium/Polyester/Aluminium Tape 100% Tinned Copper Wire Braid > 90% Low Smoke Halogen Free, UV Resistant Black

Electrical Characteristics Impedance Velocity of Propagation Capacitance Voltage Withstand Jacket Spark Conductor Resistance Outer Conductor Resistance Return Loss (30-2800MHz) Peak Power

50 Ω 85% 23.2 pF/ft (76.1 pF/m) 4.6 kV 8.0 kV (rms) ≤ 1.7 Ω/km ≤ 5.7 Ω/km ≥ 15 dB 40.0 kW

Physical Characteristics Overall Diameter Min. Bend Radius Temperature Rating Weight

15.0 mm 38.1 mm -35°C to +80°C 200 kg/km

Standards RoHS2 Compliant Low Smoke Generation Halogen Gas Emission Flame Retardant

28

Yes IEC 61034-2 IEC 60754-1&2 IEC 60332-1-2, 60332-3-24 Cat C


ANT-600H

Attenuation

Cable Cross Reference Chart

Frequency Attenuation (MHz) dB/100ft dB/100m

Antennax™ Times Microwave Andrew® ANT-600H LMR-600-FR CNT-600-FR

30 50 150 220 450 900 1500 1800 2000 2500 5800

0.5 0.6 1.0 1.2 1.7 2.5 3.3 3.7 3.9 4.4 7.2

1.6 2.0 3.2 3.8 5.6 8.2 10.8 12.0 12.7 14.5 23.6

These are actual test results from production cable. They should not be confused with the theoretical data shown in some companies catalogues.

Complete range of connectivity available

TNC Reverse Polarity Female (Spring Finger)

Attenuation performance independently verified by Telegärtner UK Ltd

29


Antennax™ ANT-600H 75 Ohm LSHF Part No: Description:

390L60H-75 ANT-600H 75 Ohm Antennax™ Feeder Cable Black LSHF

Antennax Construction Conductor Material Stranding Dielectric Diameter of Dielectric Screen Material (1) Coverage (1) Screen Material (2) Coverage (2) Outer Sheath Material Outer Sheath Colour

Copper Clad Aluminium 1/2.74 mm Foamed Polyethylene (FPE) 11.56 mm Bonded Aluminium/Polyester/Aluminium Tape 100% Tinned Copper Wire Braid > 90% Low Smoke Halogen Free, UV Resistant Black

Electrical Characteristics Impedance Velocity of Propagation Capacitance Voltage Withstand Jacket Spark Conductor Resistance Outer Conductor Resistance Return Loss (30-2500MHz) Peak Power

75 Ω 87% 15.6 pF/ft (51.2 pF/m) 4.0 kV 8.0 kV (rms) ≤ 4.7 Ω/km ≤ 5.7 Ω/km ≥ 15 dB 40.0 kW

Physical Characteristics Overall Diameter Min. Bend Radius Temperature Rating Weight

15.0 mm 38.1 mm -35°C to +80°C 201 kg/km

Standards RoHS2 Compliant Low Smoke Generation Halogen Gas Emission Flame Retardant

30

Yes IEC 61034-2 IEC 60754-1&2 IEC 60332-1-2, 60332-3-24 Cat C


ANT-600H-75

Attenuation

Cable Cross Reference Chart

Frequency Attenuation (MHz) dB/100ft dB/100m

Antennax™ Times Microwave Andrew® ANT-600H-75 Not available Not available

30 50 150 220 450 900 1500 1800 2000 2500

0.4 0.5 0.9 1.1 1.6 2.3 0.4 3.5 3.7 4.2

1.3 1.7 3 3.6 5.3 7.7 1.2 11.4 12.1 13.7

These are actual test results from production cable. They should not be confused with the theoretical data shown in some companies catalogues.

Complete range of connectivity available

N-Type Male

Attenuation performance independently verified by Telegärtner UK Ltd

31


International Sales Tel: +441727 849 841 Fax: +441727 849 842 sales@fscglobal.com www.fscglobal.com Follow us on: LinkedIn fsc-global-ltd Twitter @fscglobal UK Sales Tel: 01727 840 841 Fax: 01727 840 842 sales@fscables.com www.fscables.com Follow us on: LinkedIn flexible-&-specialist-cables Twitter @fscables Antennax™ is a brand from FS Cables in the UK and FSC Global worldwide FSC Alban Park, Hatfield Road St. Albans, Hertfordshire AL4 0JX, UK


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.