PPD and PMV calculation (Simulation in two years) Assumption The building is 4.6 meters in height, width, and depth. The interior of the building is still conditioned to 25_ C Lighting Power Density: 10.7 W/m^2 Electric Equipment: 7.6 W/m^2 There is a single, seated occupant in the center of the room, who is reading and is dressed in trousers and a short-sleeved shirt. Thermal comfort of this individual is to be determined by the Fanger model of thermal comfort.
Material Details: Material
Thickness Conductivity Density {m} {W/m-K} {kg/m3}
Specific Thermal Heat Absorptance {J/kg-K}
Solar Absorptance
WR
0.04
0.18
608
1630
0.2
0.3
CW
0.2032
1.93
2240
900
0.94
0.6
PW
0.2032
0.13
540
1210
0.82
0.7
BR
0.04
0.18
608
1630
0.9
0.8
Floor
0.15
1.93
2240
900
0.94
0.6
PPD, PMV table:
Surface Radiation impact: Surface Name
Surface Type
Sun Exposure
Surface 1
Floor
No Sun
Surface 2
Wall
No Sun
Surface 3
Wall
No Sun
Surface 4
Wall
No Sun
Surface 5
Wall
No Sun
Surface 6
Roof
Sun Exposed