Hacker Industries, Inc. - Architect Binder

Page 1

CSI DIVISIONS 03 54 13 – Gypsum Cement Underlayment 09 80 00 – Sound Treatment

ARCHITECT BINDER

Hacker Industries, Inc.


The Hacker Industries, Inc. Architectural Binder provides comprehensive information to help Architects and Builders in specifying and installing FIRM-FILL® Brand Gypsum Underlayments and FIRM-FILL® Sound Control Mats (SCM). Included in the binder are Product Specifications, CAD Details, Installation Guidelines, Warranty Information, UL Fire Rated Design listings and Acoustical Design Guidelines. Division 03 54 13 Gypsum Cement Underlayments FIRM-FILL® Brand Gypsum Underlayments are designed for use in multi-family housing, hospitality and commercial buildings to satisfy acoustical ratings and fire codes while providing flat, quick drying surfaces for finished floor coverings. All FIRM-FILL Brand Gypsum Underlayments meet ASTM F2419, Standard Practice for Installation of Thick Poured Gypsum Concrete Underlayments and the Preparation of the Surface to Receive Resilient Floor Coverings, and installation methods listed by the Tile Council of North America (TCNA). Division 09 80 00 Sound Treatment FIRM-FILL® SCM are durable, lightweight sound control mats that provide a quieter environment and meets demanding project specifications. FIRM-FILL® SCM are engineered to limit impact sound transmission between floors when used in conjunction with a FIRMFILL® Brand Gypsum Underlayments. FIRM-FILL® SCM can improve IIC ratings 15-25 points and carry a Class-A fire rating under ASTM E84.

Let Our Products Floor You™. This package includes technical information and expertiese that is confidential information of Hacker Industries, Inc. Its contents are to be maintained in the strictest confidence. The information contained herein is based on our best knowledge, experience, and research to date. It is not guaranteed to be accurate and we are not responsible for use of the information. This information is subject to change without notice. This information is the property of Hacker Industries, Inc., and is not to be reproduced in any form without the written consent of: Hacker Industries, Inc. 1600 Newport Center Drive, Suite 275 Newport Beach, CA 92660 USA Toll Free Tel. (800) 642-3455 (949) 729-3101 / Fax (949) 729-3108 www.HackerIndustries.com info@HackerIndustries.com

ii


TABLE OF CONTENTS Overview • Introduction ............................................................................................................................................................................................. ii • Choosing the Right Gypsum Floor Underlayment ....................................................................................................................1 • Choosing the Right Sound Control Mat ........................................................................................................................................3 Division 03 54 13 Gypsum Cement Underlayments: Hacker Floor Underlayments • FIRM-FILL® Gypsum Concrete .............................................................................................................................................page 6 • Product Submittal ...........................................................................................................................................................................8 • 3-Part Specifications ................................................................................................................................................................... 13 • Project References ....................................................................................................................................................................... 16 • FIRM-FILL® 2010+ .................................................................................................................................................................. page 17 • Product Submittal ........................................................................................................................................................................ 19 • 3-Part Specifications ................................................................................................................................................................... 23 • Project References ....................................................................................................................................................................... 26 • FIRM-FILL® 3310 Classic ...................................................................................................................................................... page 27 • Product Submittal ........................................................................................................................................................................ 29 • 3-Part Specifications ................................................................................................................................................................... 33 • Project References ....................................................................................................................................................................... 37 • FIRM-FILL® 3310+ .................................................................................................................................................................. page 38 • Product Submittal ........................................................................................................................................................................ 40 • 3-Part Specifications ................................................................................................................................................................... 44 • Project References ....................................................................................................................................................................... 48 • FIRM-FILL® High Strength ................................................................................................................................................. page 49 • Product Submittal ........................................................................................................................................................................ 51 • 3-Part Specifications ................................................................................................................................................................... 56 • Project References ....................................................................................................................................................................... 59 • FIRM-FILL® 4010+ .................................................................................................................................................................. page 60 • Product Submittal ........................................................................................................................................................................ 62 • 3-Part Specifications ................................................................................................................................................................... 68 • Project References ....................................................................................................................................................................... 71 • FIRM-FILL® CMD ..................................................................................................................................................................... page 72 • Product Submittal ........................................................................................................................................................................ 74 • 3-Part Specifications ................................................................................................................................................................... 78 • Project References ....................................................................................................................................................................... 81 • GYP-SPAN® Radiant .............................................................................................................................................................. page 82 • Product Submittal ........................................................................................................................................................................ 84 • 3-Part Specifications ................................................................................................................................................................... 87 • Project References ....................................................................................................................................................................... 90

Hacker Industries, Inc. | Architect Binder | © 2017

iii


Division 09 80 00 Sound Treatment : Sound Control Mats • FIRM-FILL® SCM-125 ............................................................................................................................page 92 • Product Submittal ........................................................................................................................................................................ 94 • 3-Part Specifications .................................................................................................................................................................100 • FIRM-FILL® SCM-250 ..........................................................................................................................page 103 • Product Submittal ......................................................................................................................................................................105 • 3-Part Specifications .................................................................................................................................................................112 • FIRM-FILL® SCM-400 ..........................................................................................................................page 115 • Product Submittal ......................................................................................................................................................................117 • 3-Part Specifications .................................................................................................................................................................123 • FIRM-FILL® SCM-750 ..........................................................................................................................page 127 • Product Submittal ......................................................................................................................................................................128 • 3-Part Specifications .................................................................................................................................................................131 • Hacker Sound Mat II ..........................................................................................................................page 134 • Product Submittal ......................................................................................................................................................................136 • 3-Part Specifications .................................................................................................................................................................140 • Project References .............................................................................................................................page 143 Division 03 54 13 Gypsum Cement Underlayment : Quick Reference • Quick Reference .................................................................................................................................page 145

iv

Hacker Industries, Inc. | Architect Binder | © 2017


CHOOSING THE RIGHT GYPSUM UNDERLAYMENT

US. CALIFORNIA PROPOSITION 65: WARNING: This product contains a chemical known to the State of California to cause cancer. ADDITIONAL STORAGE AND HANDLING INSTRUCTIONS Store in a dry place. Dew point conditions or other conditions causing presence of moisture may harden product during storage.

For additional information about this product, refer to the Hacker Industries Safety Data Sheet (SDS). A copy of the SDS can be obtained by writing to: Hacker Industries, Inc. 1600 Newport Center Drive, Newport Beach, CA 92660

For additional information about this product, refer to the Hacker Industries Safety Data Sheet (SDS). A copy of the SDS can be obtained by writing to: Hacker Industries, Inc. 1600 Newport Center Drive, Newport Beach, CA 92660

if you feel unwell. If in eyes: Rinse cautiously with water for several

rinsing. Immediately call a poison center/doctor. If on skin: Wash with

plenty of water. If skin irritation or rash occurs: Get medical advice/ Commercial grade strengths attention. Take off contaminated clothing and wash before reuse.

® Sound Mats and Primers Use with FIRM-FILL treatment (see section 4 on the SDS).

IF exposed or concerned: Get medical advice/attention. Specific

STORAGE: Store locked up. Store away from acids, phosphorus, diazomethan, and aluminum (at high temperatures). Protect from moisture.

HACKER INDUSTRIES, INC.

NET WT. 80.0 LB. (36.3 kg) GROSS WT. 80.5 LB. (36.5 kg)

FLOOR TOPPING MIXTURE FIRE RESISTANCE CLASSIFICATION SEE UL FIRE RESISTANCE DIRECTORY 99L4 HACKER INDUSTRIES, INC. - R10474 FOR MIXING INSTRUCTIONS PLEASE REFER TO SPECIFIC DESIGN NUMBER

if you feel unwell. If in eyes: Rinse cautiously with water for several

rinsing. Immediately call a poison center/doctor. If on skin: Wash with

® ofSound plenty water. If skin irritation or rash occurs: Get medical advice/ Use with FIRM-FILL Mats and Primers attention. Take off contaminated clothing and wash before reuse. IF exposed or concerned: Get medical advice/attention. Specific treatment (see section 4 on the SDS).

STORAGE: Store locked up. Store away from acids, phosphorus, diazomethan, and aluminum (at high temperatures). Protect from moisture.

GYPSE DE BÉTON

GYPSUM CONCRETE

Firm-Fill 3310

Classic

RADIANT

GYPSUM CONCRETE

PREVENTION: Obtain special instructions before use. Do not R ADIANT GYPSE BÉTON handle until all safety precautions have been read and understood.

Do not breathe dust. Wash thoroughly after handling. Do not eat, drink or smoke when using this product. Contaminated work clothing must not be allowed out of the workplace. Wear protective gloves/protective clothing/eye protection/face protection. After

mixing with water, do not allow prolonged contact with skin until the Gypsum-Based Cement for Radiant Heating Applications product has completely hardened and cooled.

+ + +

Appropriate for Hydronic or Electric Heating Systems RESPONSE: If swallowed: Rinse mouth. Call a poison center/doctor if you feel unwell. If in eyes: Rinse cautiously with water for several

minutes. Remove contact lenses, if present and easy to do. Continue Uniform heat transfer

rinsing. Immediately call a poison center/doctor. If on skin: Wash with

® ofSound plenty water. If skin irritation or rash occurs: Get medical advice/ Use with FIRM-FILL Mats and Primers attention. Take off contaminated clothing and wash before reuse. IF exposed or concerned: Get medical advice/attention. Specific treatment (see section 4 on the SDS).

STORAGE: Store locked up. Store away from acids, phosphorus, diazomethan, and aluminum (at high temperatures). Protect from moisture.

RADIANT GYPSUM CONCRETE

GYPSE DE BÉTON

clothing must not be allowed out of the workplace. Wear protective gloves/protective clothing/eye protection/face protection. After

Lightweight and RESPONSE: high-strength If swallowed: Rinse mouth. Call a poison center/doctor

minutes. Remove contact lenses, if present and easy to do. Continue Smooth, flat surface

GYPSUM CONCRETE

Do not breathe dust. Wash thoroughly after handling. Do not

mixing with water, do not allow prolonged contact with skin until the Gypsum-Based Cement for Corrugated Steel Deck product has completely hardened and cooled.

Harmful if swallowed. Causes skin irritation. May cause an allergic skin reaction. Causes serious eye damage. May cause cancer. Causes damage to organs (lung) through prolonged or repeated exposure.

D A N G E R

Harmful if swallowed. Causes skin irritation. May cause an allergic skin reaction. Causes serious eye damage. May cause cancer. Causes damage to organs (lung) through prolonged or repeated exposure. PREVENTION: Obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Do not breathe dust. Wash thoroughly after handling. Do not eat, drink or smoke when using this product. Contaminated work clothing must not be allowed out of the workplace. Wear protective gloves/protective clothing/eye protection/face protection. After mixing with water, do not allow prolonged contact with skin until the product has completely hardened and cooled. RESPONSE: If swallowed: Rinse mouth. Call a poison center/doctor if you feel unwell. If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a poison center/doctor. If on skin: Wash with plenty of water. If skin irritation or rash occurs: Get medical advice/ attention. Take off contaminated clothing and wash before reuse. IF exposed or concerned: Get medical advice/attention. Specific treatment (see section 4 on the SDS). STORAGE: Store locked up. Store away from acids, phosphorus, diazomethan, and aluminum (at high temperatures). Protect from moisture.

DISPOSAL: Dispose of contents/container in accordance with applicable regulations.

DISPOSAL: Dispose of contents/container in accordance with applicable regulations.

DISPOSAL: Dispose of contents/container in accordance with applicable regulations.

SUPPLEMENTAL INFORMATION: Heat develops as product hardens. May cause serious burns during hardening (rehydration) resulting in possible permanent injury.

SUPPLEMENTAL INFORMATION: Heat develops as product hardens. May cause serious burns during hardening (rehydration) resulting in possible permanent injury.

SUPPLEMENTAL INFORMATION: Heat develops as product hardens. May cause serious burns during hardening (rehydration) resulting in possible permanent injury.

SUPPLEMENTAL INFORMATION: Heat develops as product hardens. May cause serious burns during hardening (rehydration) resulting in possible permanent injury.

US. CALIFORNIA PROPOSITION 65: WARNING: This product contains a chemical known to the State of California to cause cancer.

US. CALIFORNIA PROPOSITION 65: WARNING: This product contains a chemical known to the State of California to cause cancer.

US. CALIFORNIA PROPOSITION 65: WARNING: This product contains a chemical known to the State of California to cause cancer.

US. CALIFORNIA PROPOSITION 65: WARNING: This product contains a chemical known to the State of California to cause cancer.

ADDITIONAL STORAGE AND HANDLING INSTRUCTIONS Store in a dry place. Dew point conditions or other conditions causing presence of moisture may harden product during storage.

ADDITIONAL STORAGE AND HANDLING INSTRUCTIONS Store in a dry place. Dew point conditions or other conditions causing presence of moisture may harden product during storage.

ADDITIONAL STORAGE AND HANDLING INSTRUCTIONS Store in a dry place. Dew point conditions or other conditions causing presence of moisture may harden product during storage.

ADDITIONAL STORAGE AND HANDLING INSTRUCTIONS Store in a dry place. Dew point conditions or other conditions causing presence of moisture may harden product during storage.

For additional information about this product, refer to the Hacker Industries Safety Data Sheet (SDS). A copy of the SDS can be obtained by writing to: Hacker Industries, Inc. 1600 Newport Center Drive, Newport Beach, CA 92660

For additional information about this product, refer to the Hacker Industries Safety Data Sheet (SDS). A copy of the SDS can be obtained by writing to: Hacker Industries, Inc. 1600 Newport Center Drive, Newport Beach, CA 92660

For additional information about this product, refer to the Hacker Industries Safety Data Sheet (SDS). A copy of the SDS can be obtained by writing to: Hacker Industries, Inc. 1600 Newport Center Drive, Newport Beach, CA 92660

For additional information about this product, refer to the Hacker Industries Safety Data Sheet (SDS). A copy of the SDS can be obtained by writing to: Hacker Industries, Inc. 1600 Newport Center Drive, Newport Beach, CA 92660

Firm-Fill

®

1600 Newport Center Drive, Newport Beach, CA 92660

GYPSE DE BÉTON eat, drink or smoke when using this product. Contaminated work

D A N G E R

Gyp-Span

DISPOSAL: Dispose of contents/container in accordance with applicable regulations.

Firm-Fill

Manufactured for

PREVENTION: Obtain special instructions before use. Do not GYPSUM CONCRETE handle until all safety precautions have been read and understood.

+ + +

El contenido y los recipientes se deben desechar de acuerdo a los reglamentos que correspondan.

Firm-Fill CMD

Cap new or damaged concrete RESPONSE: If swallowed: Rinse mouth. Call a poison center/doctor

minutes. Remove contact lenses, if present and easy to do. Continue Smooth, flat surface

GYPSE DE BÉTON

clothing must not be allowed out of the workplace. Wear protective gloves/protective clothing/eye protection/face protection. After

+ + + +

GYPSUM CONCRETE

HIGH STRENGTH

GYPSE DE BÉTON

Do not breathe dust. Wash thoroughly after handling. Do not

mixing with water, do not allow prolonged contact with skin until the Gypsum Cement Ideal for Renovation and Concrete Repair Use product has completely hardened and cooled.

Eliminación

Información suplementaria

ATTENTION! LE DIOXYDE DE TITANE Suceptible d’être cancérigène MESURES DE PREVENTION: En utilisant le produit, fournir ventilation d’éc happement locale et générale pour garder des concentrations en poussières dans l’air au-dessous des limites d’exposition. Utilise les méthodes de l’eau pour réduire la génération de la poussière. PREMIERS SOINS: Contact avec les yeux: Rincer immédiatement les yeux à grande eau pendant au moins 15 minutes. Obtenir une assistance médicale si les irritations se développent ou persistent. Contact cutané: En cas de contact avec la peau, se laver immédiatement avec du savon et de l’eau. Obtenir une assistance médicale si les irritations se développent ou persistent. Inhalation: Deplacer à l’air libre. Si les symptômes peristent, obtenir de l’attention médicale. VOIR LA FICHE SIGNALETIQUE POUR CE PRODUIT

HACKER INDUSTRIES, INC. | Newport Beach, CA 92660

FLOOR TOPPING MIXTURE FIRE RESISTANCE CLASSIFICATION SEE UL FIRE RESISTANCE DIRECTORY 99L4 HACKER INDUSTRIES, INC. - R10474

Se produce calor a medida que se endurece el producto. Puede causar quemaduras graves mientras se endurece (rehidratación), lo que puede ocasionar lesiones permanentes. FOR MIXING INSTRUCTIONS PLEASE REFER TO SPECIFIC DESIGN NUMBER For additional information about this product, refer to the Hacker Industries Safety Data Sheet (SDS). A copy of the SDS can be obtained by writing to: Hacker Industries, Inc. 1600 Newport Center Drive, Newport Beach, CA 92660

RADIANT

GYPSUM CONCRETE

GYPSE DE BÉTON eat, drink or smoke when using this product. Contaminated work

NET WT. 80.0 LB. (36.3 kg) GROSS WT. 80.5 LB. (36.5 kg)

Code Approvals ER #4147 MR #1255e CA472 (Modified), F2419

D A N G E R

Harmful if swallowed. Causes skin irritation. May cause an allergic skin reaction. Causes serious eye damage. May cause cancer. Causes damage to organs (lung) through prolonged or repeated exposure.

®

WARNING! May Cause Cancer PRECAUTIONS: When using product: Provide local and general exhaust ventilation to keep airborne dust concentrations below exposure limits. Use wet methods, if appropriate, to reduce the generation of dust. FIRST AID: Eye contact: Immediately flush eyes with plenty of water for at least 15 minutes. Get medical attention if irritation develops or persists. For skin contact, wash immediately with soap and water. Get medical attention immediately if irritation develops or persists. Inhalation: Remove to fresh air. If symptoms persist, obtain medical attention. SEE SAFETY DATA SHEET FOR THIS PRODUCT

1600 Newport Center Drive, Newport Beach, CA 92660

FOR MIXING INSTRUCTIONS PLEASE REFER TO SPECIFIC DESIGN NUMBER

Firm-Fill CMD

Firm-Fill

Manufactured for

P403 + P233 - Almacenar en un lugar bien ventilado. Guardar el recipiente herméticamente cerrado. Almacenar lejos de materiales incompatibles (ver sección 10 de la FDS). Proteger de la humedad.

GYPSUM CONCRETE

PREVENTION: Obtain special instructions before use. Do not GYPSUM CONCRETE handle until all safety precautions have been read and understood.

For additional information about this product, refer to the Hacker Industries Safety Data Sheet (SDS). A copy of the SDS can be obtained by writing to: Hacker Industries, Inc. 1600 Newport Center Drive, Newport Beach, CA 92660

HACKER INDUSTRIES, INC.

Almacenamiento

R ADIANT GYPSE BÉTON

Quick-drying

Use with FIRM-FILL® Sound Mats and Primers

Respuesta

FLOOR TOPPING MIXTURE FIRE RESISTANCE CLASSIFICATION SEE UL FIRE RESISTANCE DIRECTORY 99L4 HACKER INDUSTRIES, INC. - R10474

Gyp-Span

Economical solution

Corrects damaged concrete

GYPSE DE BÉTON

+ + + +

Harmful if swallowed. Causes skin irritation. May cause an allergic skin reaction. Causes serious eye damage. May cause cancer. Causes damage to organs (lung) through prolonged or repeated exposure.

US. CALIFORNIA PROPOSITION 65: WARNING: This product contains a chemical known to the State of California to cause cancer. ADDITIONAL STORAGE AND HANDLING INSTRUCTIONS Store in a dry place. Dew point conditions or other conditions causing presence of moisture may harden product during storage.

P301 + P330 + P312 - En caso de ingestión: Enjuagarse la boca. Llamar a un centro de toxicología o a un médico si la persona se encuentra mal. P305 + P351 + P338 - EN CASO DE CONTACTO CON LOS OJOS: Enjuagar con agua cuidadosamente durante varios minutos. Quitar las lentes de contacto cuando estén presentes y pueda hacerse con facilidad. Proseguir con el lavado. P310 - Llamar inmediatamente a un CENTRO DE TOXICOLOGÍA/médico. P302 + P352 - EN CASO DE CONTACTO CON LA PIEL: Lavar con agua y jabón abundantes. P333 + P313 - En caso de irritación cutánea o sarpullido: Consultar a un médico. P362 - Quitar la ropa contaminada y lavarla antes de volverla a usar. P308 + P313 - EN CASO DE exposición demostrada o supuesta: consultar a un médico. Tratamiento específico (vea la sección 4 en la hoja de datos de seguridad).

1600 Newport Center Drive, Newport Beach, CA 92660 949.729.3101 / 800.642.3455

ICC-ES HUD ASTM

Firm-Fill 4010

SUPPLEMENTAL INFORMATION: Heat develops as product hardens. May cause serious burns during hardening (rehydration) resulting in possible permanent injury.

Prevención P201 - Procurarse las instrucciones antes del uso. P202 - No manipular antes de haber leído y comprendido todas las precauciones de seguridad. P260 - No respirar polvos. P264 - Lavarse cuidadosamente después de la manipulación. P270 - No comer, beber o fumar mientras se manipula este producto. P272 - La ropa de trabajo contaminada no debe salir del lugar de trabajo. P280 - Usar equipo de protección para los ojos/la cara. P280 - Usar guantes de protección. P281 - Utilizar un equipo de protección individual, según corresponda. Después de mezclar con agua, no permita el contacto prolongado con la piel mientras el producto no se haya endurecido y enfriado por completo.

Manufactured for

RESPONSE: If swallowed: Rinse mouth. Call a poison center/doctor if you feel unwell. If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a poison center/doctor. If on skin: Wash with plenty of water. If skin irritation or rash occurs: Get medical advice/ attention. Take off contaminated clothing and wash before reuse. IF exposed or concerned: Get medical advice/attention. Specific treatment (see section 4 on the SDS).

DISPOSAL: Dispose of contents/container in accordance with applicable regulations.

H302 - Nocivo en caso de ingestión. H315 - Provoca irritación cutánea. H317 - Puede provocar una reacción cutánea alérgica. H318 - Provoca lesiones oculares graves. H350 - Puede provocar cáncer. H372 - Provoca daños en los órganos (pulmones) tras exposiciones prolongadas o repetidas.

HACKER INDUSTRIES, INC.

NET WT. 80.0 LB. (36.3 kg) GROSS WT. 80.5 LB. (36.5 kg)

FOR MIXING INSTRUCTIONS PLEASE REFER TO SPECIFIC DESIGN NUMBER

GYPSUM CONCRETE

Gypsum Cement Ideal for Concrete Repair and Leveling

ATTENTION! LE DIOXYDE DE TITANE Suceptible d’être cancérigène MESURES DE PREVENTION: En utilisant le produit, fournir ventilation d’éc happement locale et générale pour garder des concentrations en poussières dans l’air au-dessous des limites d’exposition. Utilise les méthodes de l’eau pour réduire la génération de la poussière. PREMIERS SOINS: Contact avec les yeux: Rincer immédiatement les yeux à grande eau pendant au moins 15 minutes. Obtenir une assistance médicale si les irritations se développent ou persistent. Contact cutané: En cas de contact avec la peau, se laver immédiatement avec du savon et de l’eau. Obtenir une assistance médicale si les irritations se développent ou persistent. Inhalation: Deplacer à l’air libre. Si les symptômes peristent, obtenir de l’attention médicale. VOIR LA FICHE SIGNALETIQUE POUR CE PRODUIT

PREVENTION: Obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Do not breathe dust. Wash thoroughly after handling. Do not eat, drink or smoke when using this product. Contaminated work clothing must not be allowed out of the workplace. Wear protective gloves/protective clothing/eye protection/face protection. After mixing with water, do not allow prolonged contact with skin until the product has completely hardened and cooled.

STORAGE: Store locked up. Store away from acids, phosphorus, diazomethan, and aluminum (at high temperatures). Protect from moisture.

Mexico

Peligro Indicación de peligro

HACKER INDUSTRIES, INC. | Newport Beach, CA 92660

FLOOR TOPPING MIXTURE FIRE RESISTANCE CLASSIFICATION SEE UL FIRE RESISTANCE DIRECTORY 99L4 HACKER INDUSTRIES, INC. - R10474

Firm-Fill CMD

GYPSE DE BÉTON

HIGH STRENGTH

GYPSUM CONCRETE

HIGH STRENGTH

GYPSE DE BÉTON

1600 Newport Center Drive, Newport Beach, CA 92660

D A N G E R

Firm-Fill 4010

GYPSE DE BÉTON

GYPSUM CONCRETE

Firm-Fill

Firm-Fill GYPSUM CONCRETE

NET WT. 80.0 LB. (36.3 kg) GROSS WT. 80.5 LB. (36.5 kg)

FOR MIXING INSTRUCTIONS PLEASE REFER TO SPECIFIC DESIGN NUMBER

Firm-Fill

NET WT. 80.0 LB. (36.3 kg) GROSS WT. 80.5 LB. (36.5 kg)

Manufactured for

HACKER INDUSTRIES, INC.

HACKER INDUSTRIES, INC. | Newport Beach, CA 92660

FLOOR TOPPING MIXTURE FIRE RESISTANCE CLASSIFICATION SEE UL FIRE RESISTANCE DIRECTORY 99L4 HACKER INDUSTRIES, INC. - R10474

Wash thoroughly after handling. Do not eat, drink or smoke when using this product. Contaminated work clothing should not be allowed doctor if you feel unwell. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER/doctor. IF ON SKIN: Wash with plenty of water. If skin irritation or rash occurs:

Se procurer les instructions avant utilisation. Ne pas manipuler avant d’avoir lu et compris toutes les précautions de sécurité. Ne pas respirer les poussières. Se laver soigneusement après manipulation. Ne pas manger, boire ou fumer en manipulant ce produit. Les vêtements de travail contaminés ne devraient pas sortir du lieu de travail. Porter des gants/vêtements de protection/ équipement de protection des yeux/du visage. Après avoir mélangé le produit avec de l’eau, éviter tout contact prolongé avec la peau jusqu’à ce que le produit ait complètement durci et refroidi. En cas d’ingestion : Rincer la bouche. appeler un centre antipoison ou un médecin en cas de malaise. EN CAS DE CONTACT AVEC LES YEUX: Rincer avec précaution à l’eau pendant plusieurs minutes. Enlever les lentilles de contact si la victime en porte et si elles peuvent être facilement enlevées. Continuer à rincer. Appeler immédiatement un CENTRE ANTIPOISON/un médecin. EN CAS DE CONTACT AVEC LA PEAU: Laver abondamment à l’eau. En cas d’irritation ou d’éruption cutanée: Obtenir une consultation médicale ou des soins médicaux. Enlever les vêtements contaminés et les laver avant réutilisation. EN CAS d’exposition prouvée ou suspectée : Demander un avis médical/Consulter un médecin. Traitement spécifique (voir rubrique 4 de la FS). Entreposer dans un endroit bien ventilé. Garder le contenant fermé hermétiquement. Conserver à l’écart de matières incompatibles (voir rubrique 10). Protéger de l’humidité. Éliminer le contenu/contenant conformément à la réglementation applicable.

®

WARNING! May Cause Cancer PRECAUTIONS: When using product: Provide local and general exhaust ventilation to keep airborne dust concentrations below exposure limits. Use wet methods, if appropriate, to reduce the generation of dust. FIRST AID: Eye contact: Immediately flush eyes with plenty of water for at least 15 minutes. Get medical attention if irritation develops or persists. For skin contact, wash immediately with soap and water. Get medical attention immediately if irritation develops or persists. Inhalation: Remove to fresh air. If symptoms persist, obtain medical attention. SEE SAFETY DATA SHEET FOR THIS PRODUCT

hardening (rehydration) resulting in possible permanent injury.

out of the workplace. Wear protective gloves/protective clothing/eye protection/face protection. After mixing with water, do not allow Low water demand prolonged contact with skin until the product has completely hardened and cooled. If swallowed: Rinse mouth. Call a poison center/

® contaminated clothing Get medical advice/attention. Take offSound and wash it before reuse. IF exposed or concerned: Get medical advice/ Use with FIRM-FILL Mats and Primers attention. Specific treatment (see section 4 on the SDS). Store in a well-ventilated place. Keep container tightly closed. Store away from

incompatible materials (see Section 10 of the SDS). Protect from moisture. Dispose of contents/container in accordance with applicable regulations.

Firm-Fill ATTENTION! LE DIOXYDE DE TITANE Suceptible d’être cancérigène MESURES DE PREVENTION: En utilisant le produit, fournir ventilation d’éc happement locale et générale pour garder des concentrations en poussières dans l’air au-dessous des limites d’exposition. Utilise les méthodes de l’eau pour réduire la génération de la poussière. PREMIERS SOINS: Contact avec les yeux: Rincer immédiatement les yeux à grande eau pendant au moins 15 minutes. Obtenir une assistance médicale si les irritations se développent ou persistent. Contact cutané: En cas de contact avec la peau, se laver immédiatement avec du savon et de l’eau. Obtenir une assistance médicale si les irritations se développent ou persistent. Inhalation: Deplacer à l’air libre. Si les symptômes peristent, obtenir de l’attention médicale. VOIR LA FICHE SIGNALETIQUE POUR CE PRODUIT

Hazard statement

Harmful if swallowed. Causes skin irritation. May cause an allergic skin reaction. Causes serious eye damage. May cause cancer. Causes Premium damage strength to organs (lung) through prolonged or repeated exposure. Heat develops as product hardens. May cause serious burns during

Precautionary statement Fire-resistant Obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Do not breathe dust.

Nocif en cas d’ingestion. Provoque une irritation cutanée. Peut provoquer une allergie cutanée. Provoque de graves lésions des yeux. Peut provoquer le cancer. Risque avéré d’effets graves pour les organes (poumon) à la suite d’expositions répétées ou d’une exposition prolongée. Le durcissement du produit génère de la chaleur. Peut provoquer de sérieuses brûlures pendant le durcissement (réhydratation) et entraîner des lésions permanentes.

US. CALIFORNIA PROPOSITION 65: WARNING: This product contains a chemical known to the State of California to cause cancer.

Firm-Fill 4010

1600 Newport Center Drive, Newport Beach, CA 92660

Canada

+ + + +

Conseil de prudence

ADDITIONAL STORAGE AND HANDLING INSTRUCTIONS Store in a dry place. Dew point conditions or other conditions causing presence of moisture may harden product during storage.

DO NOT INSTALL PRODUCT UNLESS TRAINED & LICENSED BY HACKER INDUSTRIES, INC. NEWPORT BEACH, CA

Manufactured for

US. California Proposition 65: WARNING: This product can expose you to chemicals including Crystalline Silica (Quartz), which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov.

Gypsum Cement Ideal for Multi-Family, Light Commercial and EN Renovation Use Danger

R ADIANT GYPSE BÉTON

SUPPLEMENTAL INFORMATION: Heat develops as product hardens. May cause serious burns during hardening (rehydration) resulting in possible permanent injury.

®

HACKER INDUSTRIES, INC.

Dispose of contents/container in accordance with applicable regulations.

Heat develops as product hardens. May cause serious burns during hardening (rehydration) resulting in possible permanent injury.

GYPSE DE BÉTON

FR-CA Danger Mention de danger

DISPOSAL: Dispose of contents/container in accordance with applicable regulations.

SUPPLEMENTAL INFORMATION: Heat develops as product hardens. May cause serious burns during hardening (rehydration) resulting in possible permanent injury.

WARNING! May Cause Cancer PRECAUTIONS: When using product: Provide local and general exhaust ventilation to keep airborne dust concentrations below exposure limits. Use wet methods, if appropriate, to reduce the generation of dust. FIRST AID: Eye contact: Immediately flush eyes with plenty of water for at least 15 minutes. Get medical attention if irritation develops or persists. For skin contact, wash immediately with soap and water. Get medical attention immediately if irritation develops or persists. Inhalation: Remove to fresh air. If symptoms persist, obtain medical attention. SEE SAFETY DATA SHEET FOR THIS PRODUCT

Disposal

GYPSUM CONCRETE Supplemental information

D A N G E R

Harmful if swallowed. Causes skin irritation. May cause an allergic skin reaction. Causes serious eye damage. May cause cancer. Causes damage to organs (lung) through prolonged or repeated exposure.

WARNING! May Cause Cancer PRECAUTIONS: When using product: Provide local and general exhaust ventilation to keep airborne dust concentrations below exposure limits. Use wet methods, if appropriate, to reduce the generation of dust. FIRST AID: Eye contact: Immediately flush eyes with plenty of water for at least 15 minutes. Get medical attention if irritation develops or persists. For skin contact, wash immediately with soap and water. Get medical attention immediately if irritation develops or persists. Inhalation: Remove to fresh air. If symptoms persist, obtain medical attention. SEE SAFETY DATA SHEET FOR THIS PRODUCT

Firm-Fill

®

ATTENTION! LE DIOXYDE DE TITANE Suceptible d’être cancérigène MESURES DE PREVENTION: En utilisant le produit, fournir ventilation d’éc happement locale et générale pour garder des concentrations en poussières dans l’air au-dessous des limites d’exposition. Utilise les méthodes de l’eau pour réduire la génération de la poussière. PREMIERS SOINS: Contact avec les yeux: Rincer immédiatement les yeux à grande eau pendant au moins 15 minutes. Obtenir une assistance médicale si les irritations se développent ou persistent. Contact cutané: En cas de contact avec la peau, se laver immédiatement avec du savon et de l’eau. Obtenir une assistance médicale si les irritations se développent ou persistent. Inhalation: Deplacer à l’air libre. Si les symptômes peristent, obtenir de l’attention médicale. VOIR LA FICHE SIGNALETIQUE POUR CE PRODUIT

HACKER INDUSTRIES, INC. | Newport Beach, CA 92660

NET WT. 80.0 LB. (36.3 kg) GROSS WT. 80.5 LB. (36.5 kg)

Manufactured for

HACKER INDUSTRIES, INC. 1600 Newport Center Drive, Newport Beach, CA 92660 FLOOR TOPPING MIXTURE FIRE RESISTANCE CLASSIFICATION SEE UL FIRE RESISTANCE DIRECTORY 99L4 HACKER INDUSTRIES, INC. - R10474 FOR MIXING INSTRUCTIONS PLEASE REFER TO SPECIFIC DESIGN NUMBER

WARNING! May Cause Cancer PRECAUTIONS: When using product: Provide local and general exhaust ventilation to keep airborne dust concentrations below exposure limits. Use wet methods, if appropriate, to reduce the generation of dust. FIRST AID: Eye contact: Immediately flush eyes with plenty of water for at least 15 minutes. Get medical attention if irritation develops or persists. For skin contact, wash immediately with soap and water. Get medical attention immediately if irritation develops or persists. Inhalation: Remove to fresh air. If symptoms persist, obtain medical attention. SEE SAFETY DATA SHEET FOR THIS PRODUCT

HACKER INDUSTRIES, INC. | Newport Beach, CA 92660

NET WT. 80.0 LB. (36.3 kg) GROSS WT. 80.5 LB. (36.5 kg)

Firm-Fill

®

ATTENTION! LE DIOXYDE DE TITANE Suceptible d’être cancérigène MESURES DE PREVENTION: En utilisant le produit, fournir ventilation d’éc happement locale et générale pour garder des concentrations en poussières dans l’air au-dessous des limites d’exposition. Utilise les méthodes de l’eau pour réduire la génération de la poussière. PREMIERS SOINS: Contact avec les yeux: Rincer immédiatement les yeux à grande eau pendant au moins 15 minutes. Obtenir une assistance médicale si les irritations se développent ou persistent. Contact cutané: En cas de contact avec la peau, se laver immédiatement avec du savon et de l’eau. Obtenir une assistance médicale si les irritations se développent ou persistent. Inhalation: Deplacer à l’air libre. Si les symptômes peristent, obtenir de l’attention médicale. VOIR LA FICHE SIGNALETIQUE POUR CE PRODUIT

Manufactured for

HACKER INDUSTRIES, INC. 1600 Newport Center Drive, Newport Beach, CA 92660 FLOOR TOPPING MIXTURE FIRE RESISTANCE CLASSIFICATION SEE UL FIRE RESISTANCE DIRECTORY 99L4 HACKER INDUSTRIES, INC. - R10474 FOR MIXING INSTRUCTIONS PLEASE REFER TO SPECIFIC DESIGN NUMBER

DO NOT INSTALL PRODUCT UNLESS TRAINED & LICENSED BY HACKER INDUSTRIES, INC. NEWPORT BEACH, CA

diazomethan, and aluminum (at high temperatures). Protect from moisture.

DISPOSAL: Dispose of contents/container in accordance with applicable regulations.

Firm-Fill

Contributes points to LEED® project certification

rinsing. Immediately call a poison center/doctor. If on skin: Wash with plenty of water. If skin irritation or rash occurs: Get medical advice/ attention. Take off contaminated clothing and wash before reuse.

IF exposed or concerned: Get medical advice/attention. Specific Low water demand treatment (see section 4 on the SDS).

If swallowed: Rinse mouth. Call a poison center/doctor if you feel unwell. If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a poison center/doctor. If on skin: Wash with plenty of water. If skin irritation or rash occurs: Get medical advice/attention. Take off contaminated clothing and wash before reuse. If exposed or concerned: Get medical advice/attention. Specific treatment (see section 4 on the SDS).

Storage

Store in a well-ventilated place. Keep container tightly closed. Store away from incompatible materials (see Section 10 of the SDS). Protect from moisture.

Gyp-Span

Fire-resistant

® Sound Mats and Primers Use with FIRM-FILL STORAGE: Store locked up. Store away from acids, phosphorus,

Obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Do not breathe dust. Wash thoroughly after handling. Do not eat, drink or smoke when using this product. Contaminated work clothing must not be allowed out of the workplace. Wear protective gloves/protective clothing/eye protection/face protection. After mixing with water, do not allow prolonged contact with skin until the product has completely hardened and cooled.

Response

WARNING! May Cause Cancer PRECAUTIONS: When using product: Provide local and general exhaust ventilation to keep airborne dust concentrations below exposure limits. Use wet methods, if appropriate, to reduce the generation of dust. FIRST AID: Eye contact: Immediately flush eyes with plenty of water for at least 15 minutes. Get medical attention if irritation develops or persists. For skin contact, wash immediately with soap and water. Get medical attention immediately if irritation develops or persists. Inhalation: Remove to fresh air. If symptoms persist, obtain medical attention. SEE SAFETY DATA SHEET FOR THIS PRODUCT

®

ATTENTION! LE DIOXYDE DE TITANE Suceptible d’être cancérigène MESURES DE PREVENTION: En utilisant le produit, fournir ventilation d’éc happement locale et générale pour garder des concentrations en poussières dans l’air au-dessous des limites d’exposition. Utilise les méthodes de l’eau pour réduire la génération de la poussière. PREMIERS SOINS: Contact avec les yeux: Rincer immédiatement les yeux à grande eau pendant au moins 15 minutes. Obtenir une assistance médicale si les irritations se développent ou persistent. Contact cutané: En cas de contact avec la peau, se laver immédiatement avec du savon et de l’eau. Obtenir une assistance médicale si les irritations se développent ou persistent. Inhalation: Deplacer à l’air libre. Si les symptômes peristent, obtenir de l’attention médicale. VOIR LA FICHE SIGNALETIQUE POUR CE PRODUIT

HACKER INDUSTRIES, INC. | Newport Beach, CA 92660

NET WT. 80.0 LB. (36.3 kg) GROSS WT. 80.5 LB. (36.5 kg)

DO NOT INSTALL PRODUCT UNLESS TRAINED & LICENSED BY HACKER INDUSTRIES, INC. NEWPORT BEACH, CA

if you feel unwell. If in eyes: Rinse cautiously with water for several

Premium strength minutes. Remove contact lenses, if present and easy to do. Continue

Firm-Fill 3310 Harmful if swallowed. Causes skin irritation. May cause an allergic skin reaction. Causes serious eye damage. May cause cancer. Causes damage to organs (lung) through prolonged or repeated exposure.

Precautionary statement Prevention

DO NOT INSTALL PRODUCT UNLESS TRAINED & LICENSED BY HACKER INDUSTRIES, INC. NEWPORT BEACH, CA

gloves/protective clothing/eye protection/face protection. After mixing with water, do not allow prolonged contact with skin until the

product has hardened and cooled. Gypsum Cement Ideal forcompletely Multi-Family, Light Commercial and Renovation Use RESPONSE: If swallowed: Rinse mouth. Call a poison center/doctor

GYPSE DE BÉTON

Do not breathe dust. Wash thoroughly after handling. Do not

eat, drink or smoke when using this product. Contaminated work GYPSE DE BÉTON Classic clothing must not be allowed out of the workplace. Wear protective

GYPSUM CONCRETE

PREVENTION: Obtain special instructions before use. Do not GYPSUM CONCRETE handle until all safety precautions have been read and understood.

US

Danger Hazard statement

DO NOT INSTALL PRODUCT UNLESS TRAINED & LICENSED BY HACKER INDUSTRIES, INC. NEWPORT BEACH, CA

IF exposed or concerned: Get medical advice/attention. Specific

STORAGE: Store locked up. Store away from acids, phosphorus, diazomethan, and aluminum (at high temperatures). Protect from moisture.

Firm-Fill 3310

RESPONSE: If swallowed: Rinse mouth. Call a poison center/doctor if you feel unwell. If in eyes: Rinse cautiously with water for several rinsing. Immediately call a poison center/doctor. If on skin: Wash with

of water. If skin irritation or rash occurs: Get medical advice/ Excellent levelingplenty attention. Take off contaminated clothing and wash before reuse.

® Sound Mats and Primers Use with FIRM-FILL treatment (see section 4 on the SDS).

DO NOT INSTALL PRODUCT UNLESS TRAINED & LICENSED BY HACKER INDUSTRIES, INC. NEWPORT BEACH, CA

Fire-rated

minutes. Remove contact lenses, if present and easy to do. Continue Sound attenuating

DO NOT INSTALL PRODUCT UNLESS TRAINED & LICENSED BY HACKER INDUSTRIES, INC. NEWPORT BEACH, CA

clothing must not be allowed out of the workplace. Wear protective gloves/protective clothing/eye protection/face protection. After

+ + + +

GYPSE DE BÉTON

Do not breathe dust. Wash thoroughly after handling. Do not

mixing with water, do not allow prolonged contact with skin until the Gypsum Underlayment Ideal for Multi-Family Use product has completely hardened and cooled.

GYPSUM CONCRETE

GYPSE DE BÉTON

GYPSE DE BÉTON eat, drink or smoke when using this product. Contaminated work

Firm-Fill 2010

GYPSUM CONCRETE

PREVENTION: Obtain special instructions before use. Do not GYPSUM CONCRETE handle until all safety precautions have been read and understood.

DO NOT INSTALL PRODUCT UNLESS TRAINED & LICENSED BY HACKER INDUSTRIES, INC. NEWPORT BEACH, CA

Sound attenuating

Use with FIRM-FILL® Sound Mats and Primers

GYPSE DE BÉTON

Superior blue bag

Flattens subfloors

Harmful if swallowed. Causes skin irritation. May cause an allergic skin reaction. Causes serious eye damage. May cause cancer. Causes damage to organs (lung) through prolonged or repeated exposure.

Classic

+ + + +

Firm-Fill 3310

GYPSUM CONCRETE

Gypsum Underlayment Ideal for Residential Use

Hacker+ Floor Underlayments

D A N G E R

Firm-Fill 3310

GYPSE DE BÉTON

Harmful if swallowed. Causes skin irritation. May cause an allergic skin reaction. Causes serious eye damage. May cause cancer. Causes damage to organs (lung) through prolonged or repeated exposure.

GYPSE DE BÉTON

GYPSUM CONCRETE

Firm-Fill 2010

GYPSUM CONCRETE

Firm-Fill

D A N G E R

Firm-Fill 3310

GYPSE DE BÉTON

GYPSUM CONCRETE

Firm-Fill 2010

GYPSE DE BÉTON

GYPSUM CONCRETE

Firm-Fill

Firm-Fill

Hacker Industries, Inc. offers a full line of eight durable Pourable Floor Underlayments to meet demanding sound-attenuating and fire-resistant specifications. With 35 years and billions of square feet of consistent installations across North America, the FIRM-FILL® product line has shown proven performance over plywood, OSB, corrugated steel deck, concrete or any structurally sound substrate.

Manufactured for

HACKER INDUSTRIES, INC. 1600 Newport Center Drive, Newport Beach, CA 92660 FLOOR TOPPING MIXTURE FIRE RESISTANCE CLASSIFICATION SEE UL FIRE RESISTANCE DIRECTORY 99L4 HACKER INDUSTRIES, INC. - R10474

WARNING! May Cause Cancer PRECAUTIONS: When using product: Provide local and general exhaust ventilation to keep airborne dust concentrations below exposure limits. Use wet methods, if appropriate, to reduce the generation of dust. FIRST AID: Eye contact: Immediately flush eyes with plenty of water for at least 15 minutes. Get medical attention if irritation develops or persists. For skin contact, wash immediately with soap and water. Get medical attention immediately if irritation develops or persists. Inhalation: Remove to fresh air. If symptoms persist, obtain medical attention. SEE SAFETY DATA SHEET FOR THIS PRODUCT

ATTENTION! LE DIOXYDE DE TITANE Suceptible d’être cancérigène MESURES DE PREVENTION: En utilisant le produit, fournir ventilation d’éc happement locale et générale pour garder des concentrations en poussières dans l’air au-dessous des limites d’exposition. Utilise les méthodes de l’eau pour réduire la génération de la poussière. PREMIERS SOINS: Contact avec les yeux: Rincer immédiatement les yeux à grande eau pendant au moins 15 minutes. Obtenir une assistance médicale si les irritations se développent ou persistent. Contact cutané: En cas de contact avec la peau, se laver immédiatement avec du savon et de l’eau. Obtenir une assistance médicale si les irritations se développent ou persistent. Inhalation: Deplacer à l’air libre. Si les symptômes peristent, obtenir de l’attention médicale. VOIR LA FICHE SIGNALETIQUE POUR CE PRODUIT

HACKER INDUSTRIES, INC. | Newport Beach, CA 92660

FOR MIXING INSTRUCTIONS PLEASE REFER TO SPECIFIC DESIGN NUMBER

FIRM-FILL® Gypsum Concrete: the ORIGINAL gypsum-based floor underlayment introduced in 1983 creates a flat, durable surface with compressive strengths up to 2000 psi and excellent STC and IIC ratings, for the ultimate sound control and fire resistance in multi-family applications. FIRM-FILL® 2010+: developed specifically for use over plywood or OSB subfloors to produce the hard, smooth surface for finished floor coverings with compressive strengths of 2000-3200 psi. FIRM-FILL® 3310 Classic: a premium poured floor underlayment delivering compressive strengths from 2000 - 3300 psi. Ideal over wood or concrete subfloors in multi-family, hospitality, and renovation projects to maximize sound control and creates an enhanced surface for finished floor coverings. FIRM-FILL® 3310+: a premium, fast-setting gypsum-based floor underlayment that maximizes sound control and creates an exceptionally smooth, flat and high-strength up to 3300 psi surface, for finished floor coverings in multi-family, hospitality or renovation projects. FIRM-FILL® High Strength: a cost-efficient leveling and resurfacing gypsum-based floor underlayment for new construction or renovation projects that installs from featheredge to 3-1/2” for a fire-resistant, soundrated and crack-resistant floor surface. FIRM-FILL® 4010+: provides compressive strengths from 4000 to 5200 psi and superior bonding characteristics for cost-effective thin-capping of damaged or uneven concrete to maximize sound control and provide fire ratings in new construction or renovation projects with no shot blasting required. FIRM-FILL® CMD: a lightweight, high-strength gypsum floor underlayment for use over corrugated steeldeck in multi-family, commercial and institutional buildings, provides superior acoustical control and fire resistant properties, and compressive strengths from 3500 psi. GYP-SPAN® Radiant: a special, non-shrinking gypsum floor underlayment designed for use over radiant heating systems that provides uniform heat transfer and compressive strengths of 2000-3200 psi for a smooth, durable and warm surface ready for finished floor coverings. All Hacker Floor Underlayments are appropriate for use over Hacker Sound Mat & FIRM-FILL® SCM-125, 250, 400 and 750.

Hacker Industries, Inc. | Architect Binder | © 2017

1


CHOOSING THE RIGHT GYPSUM UNDERLAYMENT

e yp

Commercial

Hospitality

Multi-family

T

flo

b Su

R

12003300

Wood Renovation

15003300

Concrete New

25005500

Concrete Renovation

15003300

Corrugated Steel Deck

Min. 3500

Radiant Heating

20003200

Wood New

12003300

Wood Renovation

15003300

Concrete New

25005500

Concrete Renovation

15003300

Radiant Heating

20003200

Wood New

12003300

Wood Renovation

15003300

Concrete New

25005500

Concrete Renovation

15003300

Corrugated Steel Deck

Min. 3500

Radiant Heating

20003200

■ Optional

ed

d en

m

m

o ec

Wood New

■ Recommended

2

of

or

I

PS -F

M

R FI

®

ILL

m

u ps

Gy

-F

M

R FI

®

ILL

C

+ 10

20

®

LL FI

-

M

R FI

te

re

c on

C 10

33

®

ILL

-F

M

R FI

sic

las

+ 10

33

-F

M

R FI

®

ILL

S gh

Hi

®

ILL

-F

M

R FI

h

gt

n tre

+ 10

40

-F

M

R FI

®

ILL

D

CM

®

N PA

R

t

an

i ad

-S

P GY

■ Over wood, reinforcement is required

Hacker Industries, Inc. | Architect Binder | © 2017


CHOOSING THE RIGHT SOUND CONTROL MAT Hacker Industries, Inc. offers five different Sound Control Mats to meet demanding sound-attenuating reqirements for impact nose. Over 8 million of square feet of FIRM-FILL® SCM and Hacker Sound Mats have been installed in projects thorughout North America. That number is expected to double in just three years time as the demand for better IIC ratings continues to increase.

FIRM-FILL® SCM-125: a 1/8" (3mm) sound control mat, is engineered to limit impact sound transmission in multi-family construction. Ideal for when the gypsum concrete pour is not a standard thickness, FIRM-FILL® SCM-125 is topped with a minimum of 3/4" (19mm) of a FIRM-FILL® Brand Gypsum Underlayment to create an effective low profile sound control system.

FIRM-FILL® SCM-250: is a 1/4" (6mm), random filament, corrugated, "U" groove core sound control mat designed to limit impact noise between floors. When used in conjunction with a 1" FIRM-FILL® Brand Gypsum Concrete topping, the combined system has been tested to achieve a "Light Commercial" rating from the Tile Council of North America.

FIRM-FILL® SCM-400: is a 3/8" (10mm) sound mat is efficiently engineered to limit sound transmission in multifamily construction. Ideal for when the gypsum concrete pour is not a standard thickness.

FIRM-FILL® SCM-750: is a 3/4" (19mm) sound mat, that helps create sound resistant floors with the high IIC and STC level required by IBC 2009. It is a cost-effective way to address higher IIC requirements.

Hacker Sound Mat II: an innovative sound mat is composed of 92 percent recycled rubber and is designed to provide a quieter environment and meet the most demanding project specifications.

Hacker Industries, Inc. | Architect Binder | © 2017

3


CHOOSING THE RIGHT SOUND CONTROL MAT

r loo

I-Joist

Nominal Wood

Open Web

F

4

Sy

m ste

r

ed

sh ini

F

ing

o Flo

-F

M IR

F

®

ILL

M

SC

®

ILL

-F

M IR

F

25

-1

M

SC

F

®

ILL

-F

M IR

50

-2

M

SC

00

-4

ing

r

ed

sh ini

F

o Flo

2mm Vinyl Plank

51 IIC 53 IIC

53 IIC

7mm Laminate

53 IIC

3mm Vinyl Tile

53 IIC 53 IIC

54 IIC

3mm LVT

50 IIC

2mm Vinyl Sheet

51 IIC

54 IIC

53 IIC

3mm LVT over Hacker Sound Mat

52 IIC

3mm LVT over 5mm Encore QT4005 3mm LVT over 10mm Encore QT4010

7mm Sheet Vinyl w/ Rubber Backing

57 IIC

58 IIC

58 IIC

13mm Engineered Wood

57 IIC

57 IIC

58 IIC

2mm Vinyl Plank

50 IIC 50 IIC

52 IIC

Stone Tile

51 IIC

3mm Vinyl Tile

52 IIC 50 IIC

53 IIC

Oak Flooring

54 IIC

2mm Vinyl Sheet

53 IIC

51 IIC

53 IIC

2mm Vinyl Sheet

53 IIC

2mm Vinyl Sheet over Encore QT4005

57 IIC

2mm Vinyl Sheet

52 IIC

7mm Sheet Vinyl w/ Rubber Backing

54 IIC

56 IIC

58 IIC

13mm Engineered Wood

54 IIC

54 IIC

57 IIC

2mm Vinyl Plank

50 IIC 52 IIC

54 IIC

3mm Vinyl Tile

52 IIC 52 IIC

58 IIC

2mm Vinyl Sheet

53 IIC

52 IIC

54 IIC

7mm Sheet Vinyl w/ Rubber Backing

54 IIC

57 IIC

58 IIC

13mm Engineered Wood

54 IIC

57 IIC

60 IIC

r

ke

c Ha

nd

u So

at

M

II

53 IIC

53 IIC

Hacker Industries, Inc. | Architect Binder |

| © 2017


Hacker Industries, Inc. D I V I S I O N 03 54 13 G Y P S U M C E M E N T U N D E R L AYM E N T S

Hacker Floor Underlayments FIRM-FILL® Gypsum Concrete FIRM-FILL® 2010+ FIRM-FILL® 3310 Classic FIRM-FILL® 3310+ FIRM-FILL® High Strength FIRM-FILL® 4010+ FIRM-FILL® CMD GYP-SPAN® Radiant


FIRM-FILL® GYPSUM CONCRETE, the original “blue bag” underlayment introduced by Hacker Industries, Inc. in 1983, is designed to achieve ultimate sound and fire resistance in multifamily housing. Offering exceptional compressive strengths (up to 2000 psi), it is the versatile solution for a crack-resistant, flat and durable surface ready for finished floor coverings. • Code approvals: IAPMO ER-474, ICC-ES ER-4147, LA City RR 24540 • Specify with FIRM-FILL® SCM acoustical control mats for improved acoustical performance • Crack-resistant • Lightweight; high-strength • Superior STC and IIC ratings • Over 100 UL Fire Rated Design Listings • Meets and exceeds ASTM F2419 • Installed by trained Licensed Applicators


1 - FLOOR COVERING / 2 - FIRM-FILL® GYPSUM CONCRETE UNDERLAYMENT / 3 - FIRM-FILL® SCM OR HACK 7 - PARALLEL CHORD TRUSS / 8 - TJI ® JOIST / 9 - RESILIENT CHANNEL / 10 - GYPSUM WALLBOARD / 11 - 6”

i 00 ps 0-32 nt ® Radia 200 PAN S P GY ® 2000-3300 psi

1 - FLOOR COVERING / 2 - FIRM-FILL® GYPSUM CONCRETE UNDERLAYMENT / 3 - FIRM-FILL SCM OR HACKER i ILCON M--F6” L® 7 - PARALLEL CHORD TRUSS / 8 - TJI ® JOIST / 9 - RESILIENT CHANNEL / 10 - GYPSUM WALLBOARD FI/R11 ps

L SCM OR HACKER SOUND MAT / 4 - PLYWOOD OR OSB / 5 - NOMINAL WOOD JOIST / 6 - BATT INSULATION / BOARD / 11 - 6” CONCRETE

3310

mC onc ret e

1200200 0p FIRM s -FIL i Gypsu L®

adiant R HACKER

mi 1000 psi OR OSB / 5 - NOMINAL 0 psi 2000 psi 3000 4000 psi SOUND MAT / 4 - PLYWOOD WOOD JOIST / 6psi- BATT INSULATION / n. FIR 35 - 6” CONCRETE 0 M

Firm-Fill® 4010+

2000-3300 psi 3000-3900 psi

Firm-Fill® CMD

psi 200 0-5 ® psi 400 000 ILL to 6 M-F D® CLU up FIR 010 REE 4 -SC UE TR

psi 200 0-5 ® 400 ILL M-F FIR 010 4

Ideal for multi-family construction

Gyp-Span Radiant 1200-2000

si 0p ® 20 L 3 IL 0-F 00 psi 2500-3800 M 10+ IR 20

min. 3500 psi 2000-3200 psi

(8.3-13.8 MPa)

Not a wear

Deflection must

in (building not exceed Integral part ofsurface; 100 requires Contributes points must be fully finished floor L/360 live or ® UL design listingscovering to LEEDdead project enclosed before load installation) certification

1200-2000

1200-2000 Installed

Provides compresby Hacker strengths from sive Industries' trained Licensed psi (8.31200-2000 Applicators 13.8 MPa)

Ideal for multifamily construction

Inte UL

Provides compressive strengths from 1200-2000 psi (8.3One component 13.8 MPa) Wear

Integr UL de

Deflection must not exceed L/360 7 live or dead load

Sub pro bar

Subfloor must be protected by only of an byeffective Installed vapor barrier if sound & fire Hacker installed aboveIndustries’ control system crawl space Applicators Licensed

Requires dry-in Not a wear surface; (building must be requires finished Hacker Industries, Inc. | Architect Binder | Firm-Fill® Gypsum Concrete | © 2017 ntegral part of 100 Contributes points by covering only Installed fully enclosed floor ®

FIRM-FILL ® 3310

4000-5200 psi

Provides of for Contributes Ideal multiinIntegral part Performance compressive 100 UL fire rated points to family construction wood-frame strengths from and design listings LEED® project 1200-2000 certification structures concretepsi

Performance in and wood-frame L/360 concrete structures

00-3300 psi

0 60002psi

F

2000-3200 psi

P GY

2

Firm-Fill® High Strength

psi 000 to 6 D® CLU up REE -SC UE TR

th

th

Performance in wood-frame and concrete structures

Requires dry-

1200-2000 psi

5000 psi

1200200 0p FIRM s -FIL i Gypsu L®

si

®

D M

si

ng

®

© 2017 Hacker Industries, Inc. FIRM-FILL® and the associated logos are trademarks of Hacker Industries, Inc., Newport Beach, CA.

D M

0 -F p 2000-3300 psi IL L ® si ® 2 ® F I M L R L Firm-Fill Gypsum Concrete 5 I C F 00 -38 3310 Firm-Fill® F IR 0 2010+ 0 Hig M-F p h S Classic I Firm-Fill® 3310 tre LL n mi ® 3310+g Firm-Fill n. FIR 35 00 MFI psi LL psi ® 25 LL ® C 00 3 FIR 80 0 Hig M-F p hS IL tre L

resrom (8.3-

i

1 - FLOOR COVERING / 2 - FIRM-FILL® GYPSUM CONCRETE UNDERLAYMENT / 3 - FIRM-FILL® SCM OR HACKER SOUND MAT / 4 - PLYWOOD OR OSB 00/ ps 0-32 / nt 5 - NOMINAL WOOD JOIST /6 - BATT INSULATION / 7 - PARALLEL CHORD TRUSS / 8 - TJI ® JOIST / 9 - RESILIENT CHANNEL / 10 - GYPSUM WALLBOARD ® Radia 200 AN 11 - 6” CONCRETE P S -

mC onc ret e

si

00

0 ® 20 L -3 IL 0 00 M-F 0+ IR 201

F

2

®

appropriate personal protective equipment


SUBMITTAL FORM TECHNICAL DATA Weight Thickness Compressive Strength Thermal Performance Fire Hazard Classification Sand

PROPERTIES 7 lb/ft² (34.2 kg/m²) at 3/4” (19 mm) 3/4” (19 mm) (minimum over wood) to 3-1/2” (89 mm) 1200 to 2200 psi (8.3 to 15.2 MPa) K-value of 2.45 BTU/(hr.ft.F°); R-value of 0.36 (ft².hr.F°) Flamespread index 0: Fuel contribution 0; Smoke density 0 1/8” (3 mm) or less washed plaster or masonry sand

ASTM C472 M F2419 C472 M C177 E84 C33

Flexural Strength

900 psi (6.21 MPa)

C348

Benefits • • • • • • • • •

Ideal for wood-frame, multi-family construction Essential for excellent STC and IIC ratings Install over a FIRM-FILL® SCM or Hacker Sound Mat for additional sound isolation Integral part of over 105 UL fire rated design listings Lightweight and crack-resistant Fast installation and rapid set time; may be walked on in 90 minutes Contributes points to LEED® project certification Creates a flat, durable surface for finished floor coverings Installed only by Licensed Applicators across North America

Product Description FIRM-FILL® Gypsum Concrete, "Super Blue" underlayment from Hacker Industries, Inc., is formulated for use over wood or concrete subfloors in multi-family construction. FIRM-FILL® Gypsum Concrete provides compressive strengths from 1200-2200 psi (8.3 - 15.2 MPa). Intallation after drywall. To keep project on schedule and on budget, Hacker Industries, Inc.’s Licensed Applicators can install over 40,000 ft² of FIRMFILL® Gypsum Concrete in one day. FIRM-FILL® Gypsum Concrete is mixed on the job site with local sand (per ASTM C33) and water to create a lightweight slurry. Installed at a minimum of 3/4” thick, the underlayment weighs approximately 7 lb/ft² (34.2 kg/m²) with a dry density range of 105-115 pcf. For new construction or renovation, FIRM-FILL® Gypsum Concrete is a cost-efficient way to create a smooth, hard surface for finished floor coverings, while offering exceptional compressive strengths matched with superior acoustical control and fire resistance properties. To achieve additional sound isolation, use in conjunction with a FIRM-FILL® SCM or Hacker Sound Mat.

Limitations • • • •

Shall not be used in exterior locations, below grade or where continuous exposure to moisture is likely. Shall not be used as a wear surface; must be covered by a finished floor covering. Structure shall be designed so that deflection does not exceed L/360 live or dead load. Certain floor coverings, such as marble, limestone, travertine and wood, may have more restrictive deflection limits. Consult the appropriate floor covering manufacturer for recommendations. • If installed above a crawl space, subfloor must be protected by a vapor barrier. • No single application of FIRM-FILL® Gypsum Concrete shall exceed 3-1/2” in depth. • FIRM-FILL® Gypsum Concrete is one component of an effective sound and fire control system. Care must be taken in the installation of all components to assure the ultimate design performance. Published acoustical and fire system tests were conducted under controlled laboratory or field conditions and reflect results applicable only to those specific assemblies.

8

Hacker Industries, Inc. | Architect Binder | Firm-Fill® Gypsum Concrete | © 2017


SUBMITTAL FORM Installation Before, during and after the installation of FIRM-FILL® Gypsum Concrete, the building must be enclosed and the temperature maintained at a minimum of 50°F (10°C). Prior to the installation of FIRM-FILL® Gypsum Concrete, the subfloor shall be structurally sound (L/360), broom cleaned, dry and free from oil, grease, paraffin, laitance, wax or other contaminants. Concrete subfloors shall be 28 days or older. For on-grade applications over concrete, measure the Moisture Vapor Emission Rate (MVER) per ASTM F1869. MVER shall not exceed 3 lb/1000 ft² per 24 hours. Prime wood subfloors with Hacker Floor Primer per recommended specifications before installing underlayment. Adequate ventilation shall be provided by the General Contractor (GC) to ensure proper drying of FIRM-FILL® Gypsum Concrete. If necessary, the GC shall provide mechanical ventilation. Depending on thickness and drying conditions, the underlayment should dry within 8 to 14 days. To avoid potential problems during the drying process, the GC shall consult Hacker Industries, Inc.’s Drying Conditions Flyer and information contained on Hacker Industries, Inc.’s website for additional information concerning drying of this product. After installation, temporary wood planking shall be placed by the GC wherever the floor underlayment will be subject to wheeled or concentrated loads. Finished floor coverings can be installed when the FIRM-FILL® Gypsum Concrete is completely dry. Consult flooring contractor for recommended procedures to test for dryness and acceptable levels of moisture. Reference Hacker Industries, Inc.’s Guidelines for Installing Finished Floor Coverings. This guideline is not a warranty and shall be used as a guideline only. See ASTM F2419.

Product Data Approximate Compressive Strength per ASTM C472 Modified: Approximate Dry Density (aggregated):

1200 to 2200 psi* (8.3 to 15.2 MPa) 105 to 115 pcf

*Note: Compressive strengths published herein were achieved under controlled laboratory conditions. Actual field results may differ due to environmental conditions, regional sand variations, or inconsistent proportioning of field-applied water, sand and Hacker Floor Underlayment, as well as differences in mixing/ pumping equipment.

Compliance • ICC-ES ER-4147 • City of Los Angeles Research Report No. 24540

• FHA-HUD MR 1255 • Tile Council of North America (F180, F200, RH111, RH122)

Sound Test & UL Fire Rated Designs PURPOSE STATEMENT/DISCLAIMER These guidelines are designed to provide the architectural and building communities with detailed performance data on Hacker Industries, Inc.’s comprehensive portfolio of sound attenuation tests and UL Fire Rated Designs. The tests for the assemblies included in these guidelines were conducted in a laboratory setting per ASTM C177, E84, E90, E492 and E2179. These guidelines are not warranties and should be used as guidelines only. The architects’ and general contractors’ recommendations supersede these guidelines. Field performance may vary. Subject to express Warranty stated on Hacker Industries, Inc.’s website. Hacker Industries, Inc. regularly performs acoustical and fire (UL) testing to ensure performance standards for our products. Firm-Fill® gypsum concretes, including Firm-Fill® Gypsum Concrete, were tested acoustically with the following floor assemblies and performed as noted.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® Gypsum Concrete | © 2017

9


OPEN WEB

Sound System 1: No Sound Mat, 3/4” (25 mm) FIRM-FILL® Brand Gypsum Concrete

SUBMITTAL FORM

Subfloor topping: 3/4” (25 mm) FIRM-FILL® B Subfloor: 3/4” (19 mm) oriented strand board Insulation: 3-1/2” (89 mm) unfaced R-13 fiber Truss: 18” (457 mm) L/360 open web truss Ceiling isolation: Clark Dietrich RCSD resilient Ceiling: 5/8” (16 mm) type C gypsum board

FINISH

STC

Firm Fill® Gypsum Concrete – Open Web Subfloor Topping

Sound Mat

3/4” (19mm) None FIRM-FILL® Brand Gypsum Concrete

Subfloor

¹ Insulation Bare Truss Bare

3/4” (19 mm) oriented strand board

3-1/2” (89 mm) unfaced R-13 fiberglass insulation

Ceiling Isolation

Carpet and Pad

18” Clark (457 mm) Dietrich Wood Laminate ² L/360 open RCSD 2web mm Vinyl Sheet truss resilient³ channel

Ceiling

Finish

Bare¹

REPORT #

54Sound -- Report 5005002 # Rating

51 5/8” (16 mm) type C gypsum board

IIC --

STC

IIC

54

--

52

75

D6435.29 D6435.30

5005002

Bare

--51

7004018 --52 D6435.29

Carpet & Pad

--52

7554 D6435.30 7004025

Wood -52 7004018 Laminate² ¹ Assembly varies from above in the following: Subfloor topping: 1” FIRM-FILL® Brand Gypsum mm Vinyl None -54 7004025 Subfloor: 23/32” oriented strand board; 2Insulation: Sheet³ ² Assembly varies from above in the following: Subfloor topping: 1” FIRM-FILL® Brand Gypsum ¹ Assembly varies from above in the following: Subfloor topping: 1” FIRM-FILL® Brand Gypsum Concrete; Subfloor: 23/32” oriented strand board; Insulation: None Subfloor: 23/32” oriented strand board ² Assembly varies from above in the following: Subfloor topping: 1” FIRM-FILL® Brand Gypsum Concrete; Subfloor: 23/32” oriented strand board ® ® Brand Gypsum ³ Assembly varies from above inoriented the following: 1” FIRM-FILL Brand Acoust Gypsum ³ Assembly varies from above in the following: Subfloor topping: 1”Hacker FIRM-FILL Concrete; Subfloor: 23/32” strand board;Subfloor Insulation: 9”topping: (229 mm) fiberglass batt insulation Industries, Inc. Subfloor: 23/32” oriented strand board; Insulation: 9” (229 mm) fiberglass batt insulation

Sound System FIRM-FILL® SCM-125, 3/4” (19 mm) FIRM-FILL® Brand Gypsum Concret UL Fire Rated2:Designs M503, M508 Open Web L521, L528, L529, L534, L542, L546, L550, L558, L563, L574, L576, L577, L579, L583, L585, L592, M500, ® NOMINAL WOOD

Subfloor topping: 3/4” (19Gypsum mm) FIRM-FILL Brand Concrete ® B Sound System 1: No Sound Mat, 3/4” (19 mm) FIRM-FILL Subfloor isolation: 1/8” (3 mm) FIRM-FILL® SC Subfloor3/4” topping: 3/4” oriented (19 mm)strand FIRM-FILL Subfloor: (19 mm) board® Subfloor: 3-1/2” 3/4” (19 mm) oriented strand Insulation: (89 mm) unfaced R-13board fiber Insulation: 3-1/2” (89 mm)open R-13web fiberglass Truss: 18” (457 mm) L/360 truss in Joist: isolation: 9-1/4” (235 mm) 2x10 dimensional lum Ceiling Clark Dietrich RCSD resilient Ceiling5/8” isolation: Clarktype Dietrich RCSDboard resilien Ceiling: (16 mm) C gypsum Ceiling: 5/8” (16 mm) type C gypsum board

FINISH

STC

Bare

Carpet and Pad 2 mm Vinyl Sheet Carpet andClark Pad¹ 9-1/4" 5/8" Bare (16 mm) Backing 7(235 mmmm) SheetDietrich Vinyl with Rubber Carpet and

59 -D6435.01 STC IIC REPORT # 60Sound 51 Report D6435.02 # 56 -E3149.01 61Rating 53 D6435.03 57 75 E3149.02 STC IIC 58 51 D6435.04 51 -- 76E3149.01 E4054.01 56 59 57 D6435.05 57 75 E3149.02

13 mm Engineered dimensional Resilient Wood gypsum

59

FINISH Concrete – Nominal Wood Firm Fill® Gypsum

Subfloor Topping 3/4” (19 mm) FIRM-FILL® Brand Gypsum Concrete

Sound Mat None

Subfloor

3/4" (19 mm) oriented strand board

mm Vinyl Plank Insulation 2 Bare Truss Ceiling Isolation 3 mm Vinyl Tile 3-1/2" (89 mm) R-13 fiberglass insulation

2x10

RCSD

Ceiling

type C

Finish

Pad

IIC

57

REPORT #

D6435.06

Carpet and 51 76 E4054.01 lumber Channel board ¹ Assembly varies from above in the following: Subfloor topping: 1” (25 mm) FIRM-FILL® Bran Pad¹

¹Assembly varies from above in the following: Subfloor topping: 1” (25 mm) FIRM-FILL® Brand Gypsum Concrete These guidelines shall only be a resource and are not a guarantee of performance. FIRM-FILL® SCM Underlayments are only one compon acoustical performance is affected by every other component. The likelihood of achieving code compliance is contingent upon many other ULdrywall Fire Rated Designs plumbers and contractors. Developers and®general contractors are responsible for building properly ® testing field performance as so Sound System 2: FIRM-FILL SCM-125, 3/4” (19 mm) FIRM-FILL andBrand Gypsum Concre of the project. Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or cons Nominal Wood L006, L201, L202, L206, L208, L209, L210, L211, L212, L501, L502, L503, L504, L505,correctly L506, L507, L508, L509, L510, L511, can perform to expectation a professional acoustical consultant to assure specifications are written and that the floor/ceiling assembly ® ® , GYP-SPAN and themm) associated logos are the®re ensure L517, reliability of design to occupancy. © 2/2016 Industries, FIRM-FILL Subfloor topping: 3/4” (19 FIRM-FILL L512, L513, L514, L515, L516, L519, L520,prior L522, L523, L525, L526, Hacker L532, L533, L535Inc. , L536, L537, L540, L541, L545,

L557, L569, L588, L590, L593, L598, M504, M517, M519, M530, M531, M517

10

Subfloor isolation: 1/8” (3 mm) FIRM-FILL® S Subfloor: 3/4” (19 mm) oriented strand board 5 3-1/2” (89 mm) R-13 fiberglass in Insulation: Joist: 9-1/4” (235 mm) 2x10 dimensional lum Ceiling isolation: Clark Dietrich RCSD resilien Ceiling: 5/8” (16 mm) type C gypsum board Hacker Industries, Inc. | Architect Binder | Firm-Fill® Gypsum Concrete | © 2017


SUBMITTAL FORM

Firm Fill® Gypsum Concrete – I-Joist Subfloor Topping 1” (25 mm) FIRM-FILL® Brand Gypsum Concrete

Sound Mat 1/4" (6 mm) FIRM-FILL® SCM-250 Sound Control Mat

Subfloor

3/4” (19 mm) oriented strand board

Insulation

3-1/2” (89 mm) unfaced R-11 fiberglass insulation

Joist

Ceiling Isolation

12” (302 mm) Weyerhaeuser Tus Joist® TJI® Joist

Clark Dietrich RCSD resilient channel

Ceiling

5/8” (16 mm) type C gypsum board

Finish

Sound Rating

Report #

STC

IIC

Bare

58

--

E7891.01

2 mm Vinyl Plank

621

52

E7891.02

3 mm Vinyl Tile

62

52

E7891.03

2 mm Vinyl Sheet

59

54

E7891.04

7 mm Sheet Vinyl with Rubber Backing

60

57

E7893.05

¹ Assembly differs from above in the following: Ceiling: 2 layers 5/8" (16 mm) type X gypsum board

UL Fire Rated Designs I-Joist L518, L530, L538, L547, L556, L570, L571, L581, L583, L589, M502, M506, M512

Firm Fill® Gypsum Concrete – Concrete Assembly Subfloor Topping 3/4” (19 mm) FIRM-FILL® Brand Gypsum Concrete

Sound Mat None

Subfloor

3/4" (19 mm) oriented strand board

Insulation

3-1/2" (89 mm) R-13 fiberglass insulation

Truss

9-1/4" (235 mm) 2x10 dimensional lumber

Ceiling Isolation Clark Dietrich RCSD Resilient Channel

Ceiling

5/8" (16 mm) type C gypsum board

Finish

Sound Rating

Report #

STC

IIC

Bare

56

--

E3149.01

Carpet and Pad

57

75

E3149.02

Carpet and Pad¹

51

76

E4054.01

¹Assembly varies from above in the following: Subfloor topping: 1” (25 mm) FIRM-FILL® Brand Gypsum Concrete

UL Fire Rated Designs Concrete J917, J919, J920, J924, J927, J931, J957, J991, J994

Hacker Industries, Inc. | Architect Binder | Firm-Fill® Gypsum Concrete | © 2017

11


SUBMITTAL FORM Related Products FIRM-FILL® SCM sound control mats, Hacker Floor Primer, Hacker TopCoat™ SP and Hacker Floor Sealer are available for use with FIRM-FILL® Gypsum Concrete Floor Underlayment. Contact Hacker Industries, Inc. at (800) 642-3455 or info@hackerindustries.com for more information.

Warranty Subject to express warranty stated on Hacker Industries, Inc.’s website.

Submittal Approvals Project Name Contractor/Architect Signature Date

PRODUCT INFORMATION See www.HackerIndustries.com for current recommended product specifications and literature. WARNING When mixed with water, this product hardens and becomes extremely hot. DO NOT attempt to make a cast enclosing any part of the body using this material. Failure to follow these instructions may cause severe burns that may require surgical removal of affected tissue or amputation of limb. Portland cement is strongly alkaline. Direct contact can be corrosive and cause severe damage or chemical burns to eyes and wet, moist skin. Avoid contact with eyes and skin. Wear protective glasses and clothing. If eye contact occurs, immediately flush thoroughly with water for 30 minutes and seek medical advice. Inhalation of dust may be corrosive or cause chemical burns or irritation to nose, throat and respiratory tract. Avoid breathing dust. Use a NIOSH/MSHA-approved dust respirator. Wash thoroughly with soap and water after use. Do not ingest. If ingested, call a physician. Product safety, call (800) 642-3455. KEEP OUT OF REACH OF CHILDREN.

TRADEMARKS FIRM-FILL®, GYP-SPAN®, Let Our Products Floor You™ and the associated logos are trademarks of Hacker Industries, Inc. LEED® is a registered trademark of the U.S. Green Building Council. WARRANTY HACKER INDUSTRIES, INC. SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, DIRECTLY OR INDIRECTLY SUSTAINED, NOR FOR ANY LOSS CAUSED BY APPLICATION OF THESE GOODS NOT IN ACCORDANCE WITH CURRENT PRINTED INSTRUCTION OR FOR OTHER THAN THE INTENDED USE. OUR LIABILITY IS EXPRESSLY LIMITED TO REPLACEMENT OF DEFECTIVE GOODS. ANY CLAIM SHALL BE DEEMED WAIVED UNLESS MADE IN WRITING TO US WITHIN 30 DAYS FROM DATE IT WAS, OR REASONABLY SHOULD HAVE BEEN, DISCOVERED. SAFETY FIRST Follow good safety/industrial hygiene practices during installation. Wear appropriate personal protective equipment. Read specs, MSDS and literature prior to specification and installation. © 2017 Hacker Industries, Inc., Newport Beach, CA.

12

Hacker Industries, Inc. | Architect Binder | Firm-Fill® Gypsum Concrete | © 2017


RECOMMENDED SPECIFICATIONS PART I: GENERAL 1.1

Scope

Specify to meet project requirements. The conditions of the Contract (General, Supplementary, and other conditions) and the General Requirements (Sections of Division 1) govern the provisions of this section. 1.2

Qualifications

A.

Supplier: Hacker Industries, Inc., Newport Beach, California

B.

Installer: Installation of FIRM-FILL® Gypsum Concrete shall be by a trained Licensed Applicator of Hacker Industries, Inc., using mixing and pumping equipment with a water meter approved by Hacker Industries, Inc.

C.

All materials specified herein shall be approved by Hacker Industries, Inc., Newport Beach, CA. All others shall receive prior approval.

D.

Compressive strength shall be specified from 1200 to 2200 psi (8.3 to 15.2 MPa).

E.

Materials shall be delivered in their original, unopened packages and protected from exposure to the elements before and after delivery. Do not allow bags to get wet. Product shall not be used beyond shelf life.

F.

Certification: Upon completion of this portion of the work and upon request, and as a condition of its acceptance, deliver to the architect a certificate from the Licensed Applicator, stating that the material used in this work complies with the specified requirements.

PART II: PRODUCTS 2.1

Materials

A.

Gypsum Concrete: FIRM-FILL® Gypsum Concrete, as supplied by Hacker Industries, Inc.

B.

Subfloor Primer: Hacker Floor Primer or approved equal

C.

Sand: 1/8” (3 mm) or less washed plaster or masonry sand

D.

Water: Potable and free from impurities

E.

Sealer: Hacker TopCoat™ SP (if specified)

2.2

Mix Designs: See section 3.3

PART III: PREPARATION 3.1

Condition of Subfloor

A.

Subfloor shall be structurally sound (L/360), broom cleaned, dry and free from oil, grease, paraffin, laitance, wax or other contaminants before the arrival of the Hacker Licensed Applicator.

B.

Before installation, the General Contractor (GC) shall inspect and approve the condition of the subfloor and test the existing subfloor for moisture.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® Gypsum Concrete | © 2017

13


RECOMMENDED SPECIFICATIONS (CONT.)

3.2

Preparation of Subfloor

A.

Leak Prevention: All cracks and voids shall be filled with a quick-setting patching or taping compound, or equal, where leakage may occur.

B.

Prime wood subfloors with one coat of Hacker Floor Primer (diluted 1:4 with water) using one gallon (3.78 L) per 500 ft2 (47 m2).

C.

Hacker Floor Primer recommended over concrete substrates. The Hacker Licensed Applicator can give specific recommendations.

3.3

Mixing Instructions

A.

Add 80-pound (36.3 kg) bag of FIRM-FILL® Gypsum Concrete to 6 to 7 gallons (22.7 to 26.5 L) of water followed by the specific sand ratio. Do not overwater. Water amount will vary with the wetness of the sand.

This is the proper sequence for mixing of FIRM-FILL® Gypsum Concrete.

First add water to bucket followed by FIRM-FILL® Gypsum Concrete and finally the sand.

3.4

Underlayment Application

A.

Scheduling:

1. Installation of FIRM-FILL® Gypsum Concrete shall not begin until the building is enclosed, including roof, windows, doors and other openings.

2. In the absence of Sound Mat, FIRM-FILL® Gypsum Concrete may be installed before or after the installation of drywall.

Application:

B.

1. The minimum thickness of FIRM-FILL® Gypsum Concrete varies with the type of subfloor. Over wood subfloors, a minimum of 3/4” (19 mm) is required. Over precast or poured-inplace concrete, a minimum of 1/2” (13 mm) is required.

2. Install FIRM-FILL® Gypsum Concrete at specified thickness by placing contents of bags, sand and water into the approved high-speed mixing device and blending for a minimum of one minute. FIRM-FILL® Gypsum Concrete shall be pumped onto floor areas, spreading and screeding to a smooth surface. Place as continuously as possible until installation is complete so that no FIRM-FILL® Gypsum Concrete slurry is placed against FIRM-FILL® Gypsum Concrete that has obtained its initial set, except at authorized joints.

3. FIRM-FILL® Gypsum Concrete is suitable for interior applications only and shall be covered by a finished floor covering.

14

C.

Protection: After installation, temporary wood planking shall be placed by the GC wherever the floor underlayment will be subject to wheeled or concentrated loads. The GC shall not place concentrated loads—such as pallets of material, drywall, taping compounds or any heavy items which may cause deflection—in the middle of the floor or in hallways.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® Gypsum Concrete | © 2017


RECOMMENDED SPECIFICATIONS (CONT.)

Drying: Before, during and after installation of FIRM-FILL® Gypsum Concrete, building interior shall be ventilated and heated to a minimum of 50°F (10°C) to ensure completion of the drying process. The GC shall provide continuous ventilation and adequate heat to rapidly remove moisture from the area until the FIRM-FILL® Gypsum Concrete is dry. If necessary, the GC shall provide mechanical ventilation. Do not install finished floor coverings until the FIRM-FILL® Gypsum Concrete has been tested for dryness. Consult flooring contractor for recommended procedures to test for dryness and acceptable levels of moisture. To avoid potential problems during the drying process, the GC shall consult Hacker Industries, Inc.’s Drying Conditions Flyer and information contained on Hacker Industries, Inc.’s website for additional information concerning drying of this product.

D.

3.5

Preparation for Installation of Floor Coverings

A.

Sealing: Any areas where the underlayment surface has been damaged shall be cleaned and sealed regardless of floor covering specified. Floor covering manufacturers’ specifications and requirements supersede these recommendations.

B.

Floor Covering Procedures: Please see Hacker Industries, Inc.’s Guidelines for Installing Finished Floor Coverings. The document is not a warranty and shall be used as a guideline only. See also ASTM F2419 for recommended procedures.

3.6

Field Quality Control

A.

Slump Test: FIRM-FILL® Gypsum Concrete shall be tested for slump at the beginning of each installation in order to establish the required slump. Slump tests shall then be taken periodically during installation to verify that the required slump is maintained. Slump tests shall be conducted on an approved plexiglass surface using a 2” by 4” (51 mm by 102 mm) cylinder. The acceptable patty size shall be 9” (228 mm) plus or minus 1/2” (13 mm) in diameter.

B.

Field Samples: Testing shall be done in accordance with ASTM C472 modified testing procedures using split brass molds. Prior to independent testing, consult Hacker Industries, Inc. for proper ASTM procedures

Warranty: Subject to express warranty stated on Hacker Industries, Inc.’s website.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® Gypsum Concrete | © 2017

15


PROJECT REFERENCES FIRM-FILL® Gypsum Concrete, "Super Blue" underlayment introduced by Hacker Industries, Inc. in 1983 and since improved with new technology, is designed to achieve the ultimate sound control and fire resistance in multi-family housing. With over 105 UL fire rated design listings and exceptional STC and IIC ratings, FIRMFILL® Gypsum Concrete is an excellent choice for jobs needing compressive strengths up to 2200 psi. Below is a small sample of projects that have utilized FIRM-FILL® Gypsum Concrete.

Contractor: Adolfson & Peterson Project: Campus Suites on the Rail, Coyote Landing Location: Phoenix, Arizona / Tempe, Arizona Description: Various projects with FIRM-FILL® Gypsum Concrete Contractor: A G Spanos Project: Delayne at Twin Creek Location: Allen, Texas Description: 139,220 ft² of FIRM-FILL® Gypsum Concrete Contractor: Amli Project: Quadrangle Location: Dallas, Texas Description: 148,365 ft² of FIRM-FILL® Gypsum Concrete Contractor: Camden Construction Project: The Park at Crown Valley Location: Mission Viejo, California Description: 150,000 ft² of FIRM-FILL® Gypsum Concrete Contractor: Colson and Colson Project: Grassland Estates Location: Wichita, Kansas Description: 47,000 ft² of FIRM-FILL® Gypsum Concrete Contractor: Connery Building Corporation Project: Harbor House U.S. Housing & Urban Development (HUD) Apartments Location: Madison, Wisconsin Description: 200,000 ft² of FIRM-FILL® Gypsum Concrete Contractor: Fairfield Development, LP Project: Indigo Creek Location: Thornton, Colorado Description: 140,040 ft² of FIRM-FILL® Gypsum Concrete Contractor: Fairfield Development, LP Project: Los Flores Apartments Location: Rancho Santa Margarita, California Description: 329,584 ft² of FIRM-FILL® Gypsum Concrete

16

Hacker Industries, Inc. | Architect Binder | Firm-Fill® Gypsum Concrete | © 2017


FIRM-FILL® 2010+ is Hacker Industries, Inc.’s underlayment solution over plywood or OSB subfloors in apartments, condos, hotels and motels. FIRM-FILL® 2010+ produces the hardest, smoothest surface for finished floor coverings in the industry. This new formulation has compressive strengths from 2000-3200 psi. FIRM-FILL® 2010+ also stiffens subfloors and eliminates nail squeaks and pops. Superior self-healing characteristics provide a durable, flat, non-structural surface. • Specify with Firm-Fill® SCM acoustical control mats for improved acoustical performance • Over 100 UL Fire Rated Design Listings; ICC-ES Report • Rapid, efficient installation; mixes quickly; easy to finish • Incredible surface hardness three hours after pouring • Billions of square feet of Hacker Floor Underlayments installed nationwide • Installed by trained Licensed Applicators


1 - FLOOR COVERING / 2 - FIRM-FILL® 2010+ GYPSUM CONCRETE UNDERLAYMENT / 3 - FIRM-FILL® SCM O 6 - BATT INSULATION / 7 - PARALLEL CHORD TRUSS / 8 - TJI ® JOIST / 9 - RESILIENT CHANNEL / 10 - GYPSU

i 00 ps 0-32 nt ® Radia 200 PAN S P 1 - FLOOR COVERING / 2 - FIRM-FILL CON GY ® 2010+ GYPSUM 2000-3300 psi 6 - BATT INSULATION / 7 - PARALLEL CHORD TRUSS / 8 - TJ i FIRM-FILL ® ps 00 ® 3310 2 L 3 IL 000 M-F 0+ IR 201

2

- FIRM-FILL® SCM OR HACKER SOUND MAT / 4 - PLYWOOD OR OSB / 5 - NOMINAL WOOD JOIST / ANNEL / 10 - GYPSUM WALLBOARD / 11 - 6” CONCRETE

nt ® Radia AN

1200200 0p FIRM s -FIL i Gypsu L®

F

i 00 ps

LL / 4 i- PLYWOOD OR OSB / 5 - NOMINAL WOOD JOIST / M-FILL® SCM0OR HACKER SOUND MAT ® psi 1000 2000 psi 3000 psi 25 ILL ® IRM-Fpsi C 00/ 11 - 6” CONCRETE L / 10 - F GYPSUM WALLBOARD -3

s

FIR 80 0 Hig M-F p hS IL t L r e Firm-Fill® Gypsum Concrete si

Firm-Fill® 3310+ mi

35 RM Strength Firm-Fill® IHigh 00 FI LL psi ® C

UL for 1 to 2 hour fire ratings

6000 psi

4000-5200 psi min. 3500 psi

3000-3900 psi

Gyp-Span Radiant

2000-3200 psi

2500-3800 psi

True-Screed CLU

up to 6000 psi

Ideal for plywood or OSB multi-family construction

UL design listings for 1 to 2 hour fire ratings Requires dryin (building must be fully enclosed before design listings installation)

5000 psi

2000-3200

2000-3200

psi 200 0-5 ® 400 ILL M-F FIR 010 4

Performance over concrete slabs or precast concrete

18

Firm-Fill® CMD

psi 000 to 6 D® CLU up REE -SC UE TR

th

200

esrom

®

en g

Firm-Fill® 4010+

2000-3200 psi

si

25 00 FIR -380 0 Hig M-F p hS IL tr L

D M

2000-3300 psi FIRM-FILL ® 3310

0 mpress from si a)

n.

F

1200-2000 psi

psi 200 0-5 ® 400 ILL M-F FIR 010 4

adiant

© 2017 Hacker Industries, Inc. FIRM-FILL® and the associated logos are trademarks of Hacker Industries, Inc., Newport Beach, CA.

th

Firm-Fill® 2010+

psi 000 to 6 D® CLU up REE -SC UE TR

®

ng

si

4000 psi

D M

3310

®

mC onc ret e

mi / 2 - FIRM-FILL® 2010+ CONCRETE UNDERLAYMENT / 3 - FIRM-FILL® SCM OR HACKER SOUND MAT / 4 - PLYWOOD OR OSB / 1 - FLOOR COVERING n. FIR 35 / 6 - BATT INSULATION / 7 - PARALLEL CHORD TRUSS / 8 - TJI ® JOIST / 9 - RESILIENT CHANNEL / 10 - GYPSUM WALLBOARD / 5 - NOMINAL WOOD JOIST 00 Mps-i 6” CONCRETE FI p 2000-330011

plywood or & Provides over Performance Provides UL designIdeal listingsforFast installation Installedcompresby compressive for 1 to 2OSB hour multi-family rapid set; walk on sive Hacker Industries’ from slabs or strengths concrete strengths from in 90 minutes trained Licensed construction psi concrete fire ratings precast 2000-3200 2000-3200 psi Applicators (13.8-22 MPa) (13.8-22 MPa)

Fast installation & rapid set; walk on in 90 minutes L/360

Installed only by Performance over Hacker Industries’ concrete slabs or Licensed Applicatorsprecast concrete

Not a wear Deflection must Subfloor must surface; requires not exceed L/360 be protected by finished floor live or dead load vapor barrier if covering installed by onlyabove installation & Fast Installed crawl space

One component of an effective sound & fire control system

UL for rat

Ideal for plywoo OSB multi-family construction

Wear appropriate personal protective equipment

on rapid set; walk Hacker Requires dry-in Industries’ Not a wear surface; Deflection must Applicators in 90 minutes(building Licensed must be requires finished not exceed L/360 fully enclosed floor covering live2010+ or dead load Hacker Industries, Inc. | Architect Binder | Firm-Fill® | © 2017 before installation)

Su pro ba ab


SUBMITTAL FORM TECHNICAL DATA Weight Thickness Compressive Strength Thermal Performance Fire Hazard Classification Sand Flexural Strength

PROPERTIES 7.2 lb/ft² (35.2 kg/m²) at 3/4” (19 mm) 3/4” (19 mm) (minimum over wood) to 3-1/2” (89 mm) 2000 to 3200 psi (13.8 to 22 MPa) K-value of 2.45 BTU/(hr.ft.F°); R-value of 0.36 (ft².hr.F°) Flamespread index 0: Fuel contribution 0; Smoke density 0 1/8” (3 mm) or less washed plaster or masonry sand 1100 psi (7.58 MPa)

ASTM C472 M F2419 C472 M C177 E84 C33 C348

Benefits • • • • • • • • • •

Reformulated for modern floor coverings Ideal for wood-frame, multi-family construction Contributes to excellent STC and IIC ratings Install over a FIRM-FILL® SCM or Hacker Sound Mat for additional sound isolation Ideal underlayment for use over concrete slabs or precast concrete UL fire rated designs for 1 to 2 hour fire ratings Lightweight and crack-resistant Fast installation and rapid set time; may be walked on in 90 minutes Creates a flat, durable, non-structural underlayment surface for finished floor coverings Installed only by trained Licensed Applicators across North America

Product Description FIRM-FILL® 2010+ is designed for use over wood or concrete subfloors. It stiffens the subfloor to eliminate squeaks and nail pops. With additional surface hardness, FIRM-FILL® 2010+ provides compressive strengths from 2000 to 3200 psi (13.8 to 22 MPa). Depending on the compressive strength, it may be installed before or after drywall. To keep project on schedule and on budget, Licensed Applicators may install over 25,000 ft² of FIRM-FILL® 2010+ in one day. FIRM-FILL® 2010+ is mixed on the job site with local sand (per ASTM C33) and water to create a lightweight slurry. Installed at a minimum of 3/4” thick, the underlayment weighs approximately 7.2 lb/ft² (35.2 kg/m²) with a dry density range of 105-115 pcf. For new construction, FIRM-FILL® 2010+ is a cost-effective way to create a smooth, hard surface for finished floor coverings while offering exceptional compressive strengths matched with superior acoustical control and fire resistance properties. To achieve additional sound isolation, use FIRM-FILL® 2010+ with either a FIRM-FILL® SCM sound control mat or Hacker Sound Mat.

Limitations • Do not use FIRM-FILL® 2010+ in exterior locations, below grade or where continuous exposure to moisture is likely. • Shall not be used as a wear surface; must be covered by a finished floor covering. • Structure shall be designed so that deflection does not exceed L/360 live or dead load. Certain floor coverings such as marble, limestone, travertine and wood may have more restrictive deflection limits. • If installed above a crawl space, subfloor must be protected by a vapor barrier. • No single application of FIRM-FILL® 2010+ shall exceed 3” in depth. • FIRM-FILL® 2010+ is one component of an effective sound and fire control system. Care must be taken in the installation of all components to assure the ultimate design performance. Published acoustical and fire system tests were conducted under controlled laboratory or field conditions and reflect results applicable only to those specific assemblies. Hacker Industries, Inc. | Architect Binder | Firm-Fill® 2010+ | © 2017

19


SUBMITTAL FORM Installation Before, during and after the installation of FIRM-FILL® 2010+, the building must be enclosed and the temperature maintained at a minimum of 50°F (10°C). Prior to the installation of FIRM-FILL® 2010+, the subfloor shall be structurally sound (L/360), broom cleaned, dry and free from oil, grease, paraffin, laitance, wax or other contaminants. Concrete subfloors shall be 28 days or older. For on-grade applications over concrete, measure the Moisture Vapor Emission Rate (MVER) per ASTM F1869. MVER shall not exceed 3 lb/1000 ft² per 24 hours. Prime wood subfloors with Hacker Floor Primer per recommended specifications before installing underlayment. Adequate ventilation shall be provided by the General Contractor (GC) to ensure proper drying of FIRMFILL® 2010+. If necessary, the GC shall provide mechanical ventilation. Depending on thickness and drying conditions, the underlayment should dry within 8 to 14 days. To avoid potential problems during the drying process, the GC shall consult Hacker Industries, Inc.’s Drying Conditions Flyer and information contained on Hacker Industries, Inc.’s website for additional information concerning drying of this product. After installation, temporary wood planking shall be placed by the GC wherever the floor underlayment will be subject to wheeled or concentrated loads. Finished floor coverings can be installed when the FIRM-FILL® 2010+ is completely dry. Consult flooring contractor for recommended procedures to test for dryness and acceptable levels of moisture. Reference Hacker Industries, Inc.’s Guidelines for Installing Finished Floor Coverings. This guideline is not a warranty and shall be used as a guideline only. See ASTM F2419.

Product Data Approximate Compressive Strength per ASTM C472 Modified: Approximate Dry Density (aggregated):

2000 to 3200 psi* (13.8 to 22 MPa) 105 to 115 pcf

*Note: Compressive strengths published herein were achieved under controlled laboratory conditions. Actual field results may differ due to environmental conditions, regional sand variations, or inconsistent proportioning of field-applied water, sand and Hacker Floor Underlayment, as well as differences in mixing/ pumping equipment.

Compliance • ICC-ES ER-4147 • City of Los Angeles Research Report No. 24540

• FHA-HUD MR 1255 • Tile Council of North America (F180, F200, RH111, RH122)

Sound Test & UL Fire Rated Designs PURPOSE STATEMENT/DISCLAIMER These guidelines are designed to provide the architectural and building communities with detailed performance data on Hacker Industries, Inc.’s comprehensive portfolio of sound attenuation tests and UL Fire Rated Designs. The tests for the assemblies included in these guidelines were conducted in a laboratory setting per ASTM C177, E84, E90, E492 and E2179. These guidelines are not warranties and should be used as guidelines only. The architects’ and general contractors’ recommendations supersede these guidelines. Field performance may vary. Subject to express Warranty stated on Hacker Industries, Inc.’s website. Hacker Industries, Inc. regularly performs acoustical and fire (UL) testing to ensure performance standards for our products. Firm Fill® gypsum concretes, including Firm Fill® 2010+, were tested acoustically with the following floor assemblies and performed as noted.

20

Hacker Industries, Inc. | Architect Binder | Firm-Fill® 2010+ | © 2017


OPEN WEB

Sound System 1: No Sound Mat, 3/4” (25 mm) FIRM-FILL® Brand Gypsum Concrete

SUBMITTAL FORM

Subfloor Topping

Sound Mat

3/4” None (25mm) FIRM-FILL® Brand Gypsum Concrete

Subfloor topping: 3/4” (25 mm) FIRM-FILL® B Subfloor: 3/4” (19 mm) oriented strand board Insulation: 3-1/2” (89 mm) unfaced R-13 fiber Truss: 18” (457 mm) L/360 open web truss Ceiling isolation: Clark Dietrich RCSD resilient Ceiling: 5/8” (16 mm) type C gypsum board

FINISH Firm Fill® 2010+ – Open Web ¹ Subfloor InsulationBareTruss Ceiling Ceiling Isolation Bare 3/4” (19 mm) oriented strand board

Carpet and Pad 3-1/2” 18” (457 Clark ² (89 mm) Wood mm) Laminate L/360 Dietrich unfaced open web RCSD 2truss mm Vinyl Sheet ³ R-13 resilient fiberglass channel insulation

5/8” (16 mm) type C gypsum board

STC Finish

Bare¹ Bare Carpet and Pad

IIC

54Sound-51Rating--

REPORT # 5005002 Report #D6435.29

STC 52

IIC 75

54

--

5005002

51

--

D6435.29

52

75

D6435.30

---

52

54

D6435.30 7004018

7004025

Wood Subfloor Laminate² topping: -- 1”52FIRM-FILL 7004018 ® ¹ Assembly varies from above in the following: Brand Gypsum Subfloor: 23/32” oriented strand board; Insulation: 2 mm Vinyl None -54 7004025 Sheet³Subfloor topping: 1” FIRM-FILL® Brand Gypsum ² Assembly varies from above in the following: ¹ Assembly varies from above in the following: Subfloor topping: 1” FIRM-FILL®Subfloor: Brand Gypsum23/32” Concrete; Subfloor: 23/32” orientedboard strand board; Insulation: None oriented strand ² Assembly varies from above in the following: Subfloor topping: 1” FIRM-FILL® Brand Gypsum Concrete; Subfloor: 23/32” oriented strand board ³ Assembly varies from above in the following: Subfloor topping: 1” FIRM-FILL® Brand Acoust Gypsum Hacker Industries, Inc. ³ Assembly varies from above in the following: Subfloor topping: 1” FIRM-FILL Concrete; Subfloor: 23/32” oriented strand board; Insulation: 9” (229 mm) fiberglass batt insulation ® Brand Gypsum Subfloor: 23/32” oriented strand board; Insulation: 9” (229 mm) fiberglass batt insulation

UL Fire Rated Designs Sound System 2: FIRM-FILL® SCM-125, 3/4” (19 mm) FIRM-FILL® Brand Gypsum Concret

NOMINAL WOOD

Open Web L521, L528, L529, L534, L542, L546, L550, L558, L563, L574, L576, L577, L579, L583, L585, L592, M500, M503, M508 ® Subfloor topping:®3/4” (19Gypsum mm) FIRM-FILL Brand Concrete B Sound System 1: No Sound Mat, 3/4” (19 mm) FIRM-FILL ® Subfloor isolation: 1/8” (3 mm) FIRM-FILL SC Subfloor: (19 mm) board® Subfloor3/4” topping: 3/4” oriented (19 mm)strand FIRM-FILL Insulation: (89 mm) unfaced R-13board fiber Subfloor: 3-1/2” 3/4” (19 mm) oriented strand Truss: 18” (457 mm) L/360 truss in Insulation: 3-1/2” (89 mm)open R-13web fiberglass Ceiling Clark Dietrich RCSD resilient Joist: isolation: 9-1/4” (235 mm) 2x10 dimensional lum Ceiling: (16 mm) C gypsum Ceiling5/8” isolation: Clarktype Dietrich RCSDboard resilien Ceiling: 5/8” (16 mm) type C gypsum board FINISH

Subfloor Topping

Sound Mat

3/4” (19 None mm) FIRM-FILL® Brand Gypsum Concrete

Nominal Wood

STC

IIC

REPORT #

Bare 59 -D6435.01 STC IIC REPORT # FirmFINISH Fill® 2010+ – Nominal Wood 2 mm Vinyl Plank 60 51 D6435.02 56Sound-- Report E3149.01 Subfloor Insulation Bare Truss Ceiling Ceiling Finish 3 mm Vinyl TileIsolation 61 Rating 53 D6435.03 # Carpet and Pad 57 75 E3149.02 2 mm Vinyl Sheet 58STC IIC 51 D6435.04 Carpet and Pad¹ 51 76 E4054.01 Bare -E3149.01 3/4" (19 3-1/2" Clarkwith Rubber 5/8" (16 7 9-1/4" mm Sheet Vinyl Backing 5956 57 D6435.05 mm) (89 mm) (235 mm) Dietrich mm) Carpet and 57 75 E3149.02 oriented R-13 RCSD Woodtype C 132x10 mm Engineered 59 57 D6435.06 Pad strand fiberglass Resilient gypsum CarpetSubfloor and 51 1” 76(25E4054.01 from above in the following: topping: mm) FIRM-FILL® Bran board insulation ¹ Assembly varies Channel board Pad¹

These guidelines shall only be a resource and are not a guarantee of performance. FIRM-FILL® SCM Underlayments are only one compon acoustical performance is affected by every other component. The likelihood of achieving code compliance is contingent upon many other plumbers and drywall contractors. Developers and®general contractors are responsible for building properly ® and testing field performance as so UL Laboratory FireSystem Rated Designs Sound 2: FIRM-FILL SCM-125, (19 mm) Gypsum Concre of the project. tests are not a guarantee of field performance3/4” because of the issuesFIRM-FILL noted above andBrand many other design and/or cons a professional acoustical consultant assureL501, specifications written correctly and that the floor/ceiling assembly can perform to expectation L006, L201, L202, L206, L208, L209, L210, L211, toL212, L502,are L503, L504, L505, L506, L507, L508, L509, ® ® , GYP-SPAN associated logos are the®re ensure reliability of design prior to occupancy. © 2/2016 Hacker Industries, Inc. FIRM-FILL Subfloor topping: 3/4” and (19themm) FIRM-FILL

L510, L511, L512, L513, L514, L515, L516, L517, L519, L520, L522, L523, L525, L526, L532, L533, L535 , L536, L537, L540, L541, L545, L557, L569, L588, L590, L593, L598, M504, M517,Subfloor M519, M530, M531, M517 isolation: 1/8” (3 mm) FIRM-FILL® S

I-Joist L518, L530, L538, L547, L556, L570, L581, L589, M502, M506, M512

Hacker Industries, Inc. | Architect Binder | Firm-Fill® 2010+ | © 2017

Subfloor: 3/4” (19 mm) oriented strand board 5 Insulation: 3-1/2” (89 mm) R-13 fiberglass in Joist: 9-1/4” (235 mm) 2x10 dimensional lum Ceiling isolation: Clark Dietrich RCSD resilien Ceiling: 5/8” (16 mm) type C gypsum board 21


SUBMITTAL FORM

Firm Fill® 2010+ – Concrete Assembly Subfloor Topping 1-1/4” (32 mm) FIRM-FILL® Brand Gypsum Concrete

Sound Mat

Subfloor

3/8" 6" (10 mm) (152 mm) FIRM-FILL® concrete SCM-400 Sound Control Mat

Insulation

None

Truss

None

Ceiling Isolation None

Ceiling

None

Finish

Sound Rating

Report #

STC

IIC

Bare

52

--

5014051

Bare

--

50

7014063

Sheet Vinyl

--

50

7014064

Bare

--

Δ 7014091 23*

*Tested in accordance with ASTM E2179 - Standard Test Method for Laboratory Measurement of Effectiveness of Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors.

UL Fire Rated Designs Concrete J917, J919, J920, J924, J927, J931, J957, J991, J994

Related Products

Submittal Approvals

FIRM-FILL® SCM sound control mats, Hacker Floor Primer, Hacker TopCoat™ SP and Hacker Floor Sealer are available for use with FIRM-FILL® 2010+. Contact Hacker Industries, Inc. at (800) 642-3455 f or info@hackerindustries.com or more information.

Project Name

Contractor/Architect

Signature

Warranty Subject to express warranty stated on Hacker Industries, Inc.’s website.

PRODUCT INFORMATION See www.HackerIndustries.com for current recommended product specifications and literature. WARNING When mixed with water, this product hardens and becomes extremely hot. DO NOT attempt to make a cast enclosing any part of the body using this material. Failure to follow these instructions may cause severe burns that may require surgical removal of affected tissue or amputation of limb. Portland cement is strongly alkaline. Direct contact can be corrosive and cause severe damage or chemical burns to eyes and wet, moist skin. Avoid contact with eyes and skin. Wear protective glasses and clothing. If eye contact occurs, immediately flush thoroughly with water for 30 minutes and seek medical advice. Inhalation of dust may be corrosive or cause chemical burns or irritation to nose, throat and respiratory tract. Avoid breathing dust. Use a NIOSH/MSHA-approved dust respirator. Wash thoroughly with soap and water after use. Do not ingest. If ingested, call a physician. Product safety, call (800) 642-3455. KEEP OUT OF REACH OF CHILDREN.

Date

TRADEMARKS FIRM-FILL®, GYP-SPAN®, Let Our Products Floor You™ and the associated logos are trademarks of Hacker Industries, Inc. LEED® is a registered trademark of the U.S. Green Building Council. WARRANTY HACKER INDUSTRIES, INC. SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, DIRECTLY OR INDIRECTLY SUSTAINED, NOR FOR ANY LOSS CAUSED BY APPLICATION OF THESE GOODS NOT IN ACCORDANCE WITH CURRENT PRINTED INSTRUCTION OR FOR OTHER THAN THE INTENDED USE. OUR LIABILITY IS EXPRESSLY LIMITED TO REPLACEMENT OF DEFECTIVE GOODS. ANY CLAIM SHALL BE DEEMED WAIVED UNLESS MADE IN WRITING TO US WITHIN 30 DAYS FROM DATE IT WAS, OR REASONABLY SHOULD HAVE BEEN, DISCOVERED. SAFETY FIRST Follow good safety/industrial hygiene practices during installation. Wear appropriate personal protective equipment. Read specs, MSDS and literature prior to specification and installation. © 2017 Hacker Industries, Inc., Newport Beach, CA.

22

Hacker Industries, Inc. | Architect Binder | Firm-Fill® 2010+ | © 2017


RECOMMENDED SPECIFICATIONS PART I: GENERAL 1.1

Scope

Specify to meet project requirements. The conditions of the Contract (General, Supplementary, and other conditions) and the General Requirements (sections of Division 1) govern the provisions of this section. 1.2

Qualifications

A.

Supplier: Hacker Industries, Inc., Newport Beach, California

B.

Installer: Installation of FIRM-FILL® 2010+ shall be by a trained Licensed Applicator of Hacker Industries, Inc., using mixing and pumping equipment with a water meter approved by Hacker Industries, Inc.

C.

All materials specified herein shall be approved by Hacker Industries, Inc., Newport Beach, CA. All others shall receive prior approval.

D.

Compressive strength can be specified from 2000 to 3200 psi (13.8 to 22.1 MPa).

E.

Materials shall be delivered in their original, unopened packages and protected from exposure to the elements before and after delivery. Do not allow bags to get wet. Product shall not be used beyond shelf life.

F.

Certification: Upon completion of this portion of the work, and as a condition of its acceptance, deliver to the architect a certificate from Hacker Industries, Inc., signed by the Licensed Applicator, stating that the material used in this work complies with the specified requirements.

PART II: PRODUCTS 2.1

Materials

A.

Gypsum Concrete: FIRM-FILL® 2010+ as supplied by Hacker Industries, Inc.

B.

Subfloor Primer: Hacker Floor Primer or approved equal

C.

Sand: 1/8” (3 mm) or less washed plaster or masonry sand meeting requirements of Hacker Industries, Inc.’s Sand Guidelines

D.

Water: Potable and free from impurities

E.

Sealer: Hacker TopCoat™ SP (if specified)

2.2

Mix Design: See section 3.3

PART III: PREPARATION 3.1

Condition of Subfloor

A.

Subfloor shall be structurally sound (L/360), broom cleaned, dry and free from oil, grease, paraffin, laitance, wax or other contaminants before the arrival of the Hacker Licensed Applicator.

B.

Before installation, the General Contractor (GC) shall inspect and approve the condition of the subfloor and test the existing subfloor for moisture.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® 2010+ | © 2017

23


RECOMMENDED SPECIFICATIONS (CONT.)

3.2

Preparation of Subfloor

A.

Leak Prevention: All cracks and voids shall be filled with a quicksetting patching or taping compound, or equal, where leakage may occur.

B.

Prime wood subfloors with one coat of Hacker Floor Primer (diluted 1:4 with water) using one gallon (3.78 L) per 500 ft2 (47 m2).

C.

Hacker Floor Primer is not always required over concrete substrates. Multiple coats may be required over porous concrete or plank. The Hacker Licensed Applicator can give specific recommendations. (Note: For rehabilitation work or pours over old and/or porous concrete, consult a Licensed Applicator or Hacker Industries, Inc., for recommended preparation.)

3.3

Mixing Instructions

A.

Add 80-pound (36.3 kg) bag of FIRM-FILL® 2010+ to 6 to 7 gallons (22.7 to 26.5 L) of water followed by the specific sand ratio. Do not overwater. Water amount will vary with the wetness of the sand.

This is the proper sequence for mixing of FIRM-FILL® 2010+.

First add water to bucket followed by FIRM-FILL® 2010+ and finally the sand.

3.4

Underlayment Application

A.

Scheduling: 1. Installation of FIRM-FILL® 2010+ shall not begin until the building is enclosed, including roof, windows, doors and other openings.

2. FIRM-FILL® 2010+ may be installed before or after the installation of drywall, as specified.

B.

Application:

1. The minimum thickness of FIRM-FILL® 2010+ varies with the type of subfloor. Over wood subfloors, a minimum of 3/4” (19 mm) is required. Over precast or poured-in-place concrete, a minimum of 1/2” (13 mm) is required.

2. Install FIRM-FILL® 2010+ at specified thickness by placing contents of bags, sand and water into the approved high-speed mixing device and blending for a minimum of one minute. FIRM-FILL® 2010+ shall be pumped onto floor areas, spreading and screeding to a smooth surface. Place as continuously as possible until installation is complete so that no FIRM-FILL® 2010+ slurry is placed against FIRM-FILL® 2010+ that has obtained its initial set, except at authorized joints.

3. FIRM-FILL® 2010+ is suitable for interior applications only and must be covered by a finished floor material.

C.

Protection: After installation, temporary wood planking shall be placed by the GC wherever the floor underlayment will be subjected to wheeled or concentrated loads. The GC shall not place concentrated loads—such as pallets of material, drywall, taping compounds or any heavy items which may cause deflection—in the middle of the floor or in hallways.

D.

Drying: Before, during and after installation of FIRM-FILL® 2010+, building interior shall be ventilated and heated to a minimum 50°F (10°C) to ensure completion of the drying process. The GC shall provide continuous ventilation and adequate heat to rapidly remove moisture

24

Hacker Industries, Inc. | Architect Binder | Firm-Fill® 2010+ | © 2017


RECOMMENDED SPECIFICATIONS (CONT.)

from the area until the FIRM-FILL® 2010+ is dry. If necessary, the GC shall provide mechanical ventilation. Do not install finished floor coverings until the FIRM-FILL® 2010+ is tested for dryness. Consult flooring contractor for recommended procedures to test for dryness and acceptable levels of moisture. To avoid potential problems during the drying process, the GC shall consult Hacker Industries, Inc.’s Drying Conditions Flyer and information contained on Hacker Industries, Inc.’s website for additional information concerning drying of this product. 3.5

Preparation for Installation of Floor Coverings

A.

Sealing: Any areas where the underlayment surface has been damaged shall be cleaned and sealed regardless of floor covering specified. Floor covering manufacturers’ specifications and requirements supersede these recommendations.

B.

Floor Covering Procedures: Please see Hacker Industries, Inc.’s Guidelines for Installing Finished Floor Coverings. The guideline is not a warranty and shall be used as a guideline only. See also ASTM F2419 for recommended procedures.

3.6

Field Quality Control

A.

Slump Test: FIRM-FILL® 2010+ shall be tested for slump at the beginning of each installation in order to establish the required slump. Slump tests shall then be taken periodically during installation to verify that the required slump is maintained. Slump tests shall be conducted using a 2” by 4” (51 mm by 102 mm) cylinder. The acceptable patty size shall be 9” (228 mm) plus or minus 1/2” (13 mm) in diameter.

B.

Field Samples: Testing shall be done in accordance with ASTM C472 modified testing procedures, using split brass molds. Prior to independent testing, consult Hacker Industries, Inc. for proper ASTM procedures.

Warranty: Subject to express warranty stated on Hacker Industries, Inc.’s website.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® 2010+ | © 2017

25


PROJECT REFERENCES With additional surface hardness, FIRM-FILL® 2010+ is the underlayment solution over wood or concrete subfloors in apartments, custom homes, and renovation projects. FIRM-FILL® 2010+ stiffens wood subfloors and eliminates nail squeaks and pops, providing a smooth, flat surface for finished floor coverings. Below is a small sample of projects that have utilized FIRM-FILL® 2010+. Contractor: Brown Construction Project: The Haven @ Cottle Station Location: San Jose, California Description: 56,562 ft² of FIRM-FILL® 2010+

Contractor: Frana & Sons Project: Orchard Square Apartments Location: Apple Valley, Minnesota Description: 59,098 ft² of FIRM-FILL® 2010

Contractor: Flaherty & Collins, Inc. Project: Linden Square Location: Gladstone, Missouri Description: 290,000 ft² of FIRM-FILL® 2010+

Contractor: FWS Construction Project: The Waverly Retirement Center Location: Winnipeg, Manitoba, Canada Description: 15,500 m² of FIRM-FILL® 2010

Contractor: Mark-Taylor Development Project: Villas @ San Dorado Location: Oro Valley, Arizona Description: 185,000 ft² of FIRM-FILL® 2010+

Contractor: John Daniels Construction Project: Microtel Inn Location: Bozeman, Montana Description: 20,000 ft² of FIRM-FILL® 2010

Contractor: NexGen Construction Co Project: Seven Apts Location: Phoenix, Arizona Description: 143,730 ft² of FIRM-FILL® 2010+

Contractor: JPI Apartment Construction Project: The Pointe Location: State College, Pennsylvania Description: 215,000 ft² of FIRM-FILL® 2010

Contractor: SBI Builders Project: Fuller Street Apts Location: Redwood City, California Description: 104,650 ft² of FIRM-FILL® 2010+

Contractor: KCC Contractors, Inc. Project: Courtyard by Marriott Location: Springfield, Missouri Description: 52,000 ft² of FIRM-FILL® 2010

Contractor: Tanamera Project: Villas @ Keystone Canyon Location: Reno, Nevada Description: 334,940 ft² of FIRM-FILL® 2010+ Contractor: Colson & Colson Project: Grassland Estates Location: Wichita, Kansas Description: 16,000 ft² of FIRM-FILL® 2010 Contractor: Estes Project: Coventry Retail Offices Location: Davenport, Iowa Description: 13,000 ft² of FIRM-FILL® 2010 Contractor: Fairway Construction Project: Townsend and Wall Location: St. Joseph, Missouri Description: 40,776 ft² of FIRM-FILL® 2010

26

Hacker Industries, Inc. | Architect Binder | Firm-Fill® 2010+ | © 2017


FIRM-FILL® 3310 Classic is a premier gypsum underlayment ideal for wood

frame, light commercial, renovation, and hospitality projects. FIRM-FILL® 3310 Classic requires less water, allowing for accelerated drying time and unparalleled levels of strength and finish. • Compressive strength from 2000–3300 psi (13.8–22.8 MPa) • Apply from 3/4” (19mm) to 3-1/2” (89mm) • Acceptable with a variety of finished floor coverings • Over 100 UL fire rated designs • Fast application and quick drying time


1 - FLOOR COVERING / 2 - FIRM-FILL® 3310 GYPSUM CONCRETE UNDERLAYMENT / 3 - FIRM-FILL® SCM OR 6 - BATT INSULATION / 7 - PARALLEL CHORD TRUSS / 8 - TJI ® JOIST / 9 - RESILIENT CHANNEL / 10 - GYPSUM

i 00 ps 0-32 0 nt 0 ® Radia 2 P AN S P GY 2000-3300 psi

i ® F I R M -F I L L FIRM-FILL® SCM OR HACKER SOUND MAT / 4 - PLYWOOD OR 1 - FLOOR OSB / 5 COVERING - NOMINAL /WOOD 2 - FIRM-FILL JOIST /® 3310 GYPSUM CONCRETE UNDERLAYMENT / 3 - 0FIRM-FILL SCM OR HAC ps 0 ® ® 3310 2 6 - BATT INSULATION / 7 - PARALLEL CHORD TRUSS / 8 - TJI JOIST / 9 - RESILIENT CHANNEL NNEL / 10 - GYPSUM WALLBOARD / 11 - 6” CONCRETE -3 L L / 10 - GYPSUM WA I 0 00 M -F 0+ I R 201

F

2

®

mC onc ret e

Firm-Fill® High Strength

2000-3200 psi

Firm-Fill® 4010+ Gyp-Span Radiant 2000-3300

min. 3500 psi 2000-3200 psi F

Firm-Fill® CMD

2000-3300 psi 3000-3900 psi

High-strength for use over wood or concrete subfloors

2000-3300

Ideal for multifamily construction

Provides

UL design listings

Fast installation &

Installed by

for rapid multicompresHigh-strength Provides compressive for for 1 to 2 Ideal hour fire set; walk on Hacker Industries’ 2000-3300 strengths from ratings in 90 minutes trained Licensed family construction sive strengths from use over wood or 2000-3300 psi Applicators psi subfloors concrete 2000-3300 (13.8-22.8 MPa) (13.8-22.8.8 MPa)

UL design listings for 1 to 2 hour fire Requires dryratings in (building must be fully enclosed before design listings installation)

UL for 1 to 2 hour fire ratings 28

H

2

1200-2000 psi

psi 000 to 6 D® CLU up i REE 00 ps 0 6 -S C o t UE D® CLU up TR REE psi -S C 200 UE 0-5 ® R 400 IL L T psi M -F 200 0-5 F I R 010 ® 4 400 IL L D M -F M F I R 010 4 si

Pa)

th

esrom

®

mpress from si MPa)

si

00

th

300

ng

4000 psi

0-3 nt ® Radia 200 P AN 5000 psi 6000 psi S P GY 2000-3300 psi i s F I R M -F I L L ® 0p ® 0psi 2500-3800 3310 2 L 3 IL 0-F + 00 Mpsi 4000-5200 0 I R 201

®

© 2017 Hacker Industries, Inc. FIRM-FILL® and the associated logos are trademarks of Hacker Industries, Inc., Newport Beach, CA.

D M

-F p 2000-3300 psi IL L ® si ® 2 F I M L R L 5 C FI 00 -38 3310 Firm-Fill® FGypsum IR 00 Concrete M Hi p h S FIL si Firm-Fill® g2010+ tre L n t g Radian mi Classic Firm-Fill® 3310 n. FIR 35 00 MFirm-Fill® 3310+ FI 2000-3300 psi L L psi ® 25 C F I R M -F I L L ® 00 3310 F I R -380 0 M Hig p h S FIL tre L

1200200 0p FIR M si -F I L Gypsu L®

®

onc ret e

adiant

N R ® SCM OR HACKER SOUNDmMAT M-FILL in. / 4 - PLYWOOD OR OSB / 5 - NOMINAL WOOD JOIST / 0 psi 1000 psi 2000 psi 3000 psi F 35 CONCRETE EL / 10 - GYPSUM WALLBOARDI R/ M 11 - 6” 00

1200200 0p FIR M si -F I L Gypsu L® mC

i 00 ps

1 - FLOOR COVERING / 2 - FIRM-FILL® 3310 CLASSIC CONCRETE UNDERLAYMENT / 3 - FIRM-FILL® SCM OR HACKER SOUND MAT / 4 - PLYWOOD OR OSB / 5 - NOMINAL WOOD JOIST / 6 - BATT INSULATION / 7 - PARALLEL CHORD TRUSS / 8 - TJI ® JOIST / 9 - RESILIENT CHANNEL / 10 - GYPSUM WALLBOARD / psi 11 - 6” CONCRETE 200

L/360 Ideal forby multi& forInstalled only High-strength Fast installation Provides compresfamily construction sive strengths from wood orHacker Industries’ over on use walk rapid set; Not ainwear Deflection must Licensed Subfloor must One component Wear appropriate psi subfloors Applicators 90 minutes concrete 2000-3300 surface; requires not exceed L/360 be protected by of an effective personal MPa) finished floor live or dead load vapor barrier if sound & fire(13.8-22.8.8 protective

covering

installed above

control system

UL for rati

UL des for 1 to ratings

equipment

by only Fast installation & Installed crawl space on walk rapid set; Hacker Industries’ Requires dry-in Not a wear surface; Deflection must in 90 minutes Licensed Applicators (building must be requires finished not exceed L/360 Hacker Industries, Inc. | Architect Binder | FIRM-FILL® 3310 | © 2017 fully enclosed floor covering liveClassic or dead load before installation)

Sub pro bar abo


SUBMITTAL FORM TECHNICAL DATA

PROPERTIES

ASTM

Weight

7.6 lb/ft² (37.1 kg/m²) at 3/4” (19 mm)

C472 M

Thickness

Wood: 3/4” (19 mm) to 3-1/2” (89 mm); Concrete: 1/2” (13 mm) to 3-1/2” (89 mm)

F2419

Compressive Strength

2000 to 3300 psi (13.8 to 22.8 MPa)

C472 M

Thermal Performance

K-value of 2.8 BTU/(hr.ft.F°); R-value of 0.36 (ft².hr.F°)

C177

Fire Hazard Classification

Flamespread index 0: Fuel contribution 0; Smoke density 0

E84

Sand

1/8” (3 mm) or less washed plaster or masonry sand

C33

Flexural Strength

1100 psi (7.58 MPa)

C348

Benefits • • • • • • • • •

High-strength underlayment for use over wood or concrete subfloors Install over a FIRM-FILL® SCM or Hacker Sound Mat for additional sound isolation Contributes to excellent STC and IIC ratings UL designs for 1 to 3 hour fire ratings Lightweight and crack-resistant Reduced amount of water for accelerated drying time Contributes points to LEED® project certification Creates a flat, durable, non-structural underlayment surface for finished floor coverings Installed only by trained Licensed Applicators across North America

Product Description FIRM-FILL® 3310 Classic offers an innovative formulation that decreases the amount of water used while enhancing the rock-solid floor strength. The product’s rapid set time allows light foot traffic in 90 minutes. This versatile, high quality floor underlayment is widely used as an alternative to lightweight concrete in multifamily, light commercial and hospitality projects. FIRM-FILL® 3310 Classic provides compressive strengths from 2000 to 3300 psi (13.8 to 22.8 MPa). Depending on compressive strength, it can be installed before or after drywall. To help keep projects on schedule and on budget, Licensed Applicators can install over 25,000 ft² of FIRM-FILL® 3310 Classic in one day. FIRM-FILL® 3310 Classic is mixed on the job site with local sand (per ASTM C33) and water to create a lightweight slurry. Installed at a minimum of 3/4” thick, the underlayment weighs approximately 7.6 lb/ft² (37 kg/m²) with a dry density range of 107-120 pcf. For new construction, FIRM-FILL® 3310 Classic is a cost-efficient way to maximize sound control and create a smooth, flat and high-strength surface for finished floor coverings. To achieve additional sound isolation, use FIRM-FILL® 3310 Classic with either a FIRM-FILL® SCM sound control mat or Hacker Sound Mat.

Limitations • Do not use FIRM-FILL® 3310 Classic in exterior locations, below grade or where continuous exposure to moisture is likely. • Shall not be used as a wear surface; must be covered by a finished floor covering. • Structure shall be designed so that deflection does not exceed L/360 live or dead load. Certain floor coverings, such as marble, limestone, travertine and wood, may have more restrictive deflection limits. Consult the appropriate floor covering manufacturer for recommendations. • If installed above a crawl space, subfloor must be protected by a vapor barrier. • No single application of FIRM-FILL® 3310+ shall exceed 3” in depth. • FIRM-FILL® 3310 Classic is one component of an effective sound and fire control system. Care must be taken in the installation of all components to assure the ultimate design performance. Published acoustical and fire system tests were conducted under controlled laboratory or field conditions and reflect results applicable only to those specific assemblies. Hacker Industries, Inc. | Architect Binder | FIRM-FILL® 3310 Classic | © 2017

29


SUBMITTAL FORM Installation Before, during and after the installation of FIRM-FILL® 3310 Classic, the building must be enclosed and the temperature maintained at a minimum of 50°F (10°C). Prior to the installation of FIRM-FILL® 3310 Classic, the subfloor shall be structurally sound (L/360), broom cleaned, dry and free from oil, grease, paraffin, laitance, wax or other contaminants. Concrete subfloors shall be 28 days or older. For on-grade applications over concrete, measure the Moisture Vapor Emission Rate (MVER) per ASTM F1869. MVER shall not exceed 3 lb/1000 ft² per 24 hours. Prime wood subfloors with Hacker Floor Primer per recommended specifications before installing underlayment. Adequate ventilation shall be provided by the General Contractor (GC) to ensure proper drying of FIRM-FILL® 3310 Classic. If necessary, the GC shall provide mechanical ventilation. Depending on thickness and drying conditions, the underlayment should dry within 8 to 14 days. To avoid potential problems during the drying process, the GC shall consult Hacker Industries, Inc.’s Drying Conditions Flyer and information contained on Hacker Industries, Inc.’s website for additional information concerning drying of this product. After installation, temporary wood planking shall be placed by the GC wherever the floor underlayment will be subject to wheeled or concentrated loads. Finished floor coverings can be installed when the FIRM-FILL® 3310 Classic is completely dry. Consult flooring contractor for recommended procedures to test for dryness and acceptable levels of moisture. Reference Hacker Industries, Inc.’s Guidelines for Installing Finished Floor Coverings. This guideline is not a warranty and shall be used as a guideline only. See ASTM F2419.

Product Data Approximate Compressive Strength per ASTM C472 Modified: Approximate Dry Density (aggregated):

2000 to 3200 psi* (13.8 to 22.8 MPa) 102 to 120 pcf

*Note: Compressive strengths published herein were achieved under controlled laboratory conditions. Actual field results may differ due to environmental conditions, regional sand variations, or inconsistent proportioning of field-applied water, sand and Hacker Floor Underlayment, as well as differences in mixing/ pumping equipment.

Compliance • ICC-ES ER-4147 • City of Los Angeles Research Report No. 24540

• FHA-HUD MR 1255 • Tile Council of North America (F180, F200, RH111, RH122)

Sound Test & UL Fire Rated Designs PURPOSE STATEMENT/DISCLAIMER

These guidelines are designed to provide the architectural and building communities with detailed performance data on Hacker Industries, Inc.’s comprehensive portfolio of sound attenuation tests and UL Fire Rated Designs. The tests for the assemblies included in these guidelines were conducted in a laboratory setting per ASTM C177, E84, E90, E492 and E2179. These guidelines are not warranties and should be used as guidelines only. The architects’ and general contractors’ recommendations supersede these guidelines. Field performance may vary. Subject to express Warranty stated on Hacker Industries, Inc.’s website. Hacker Industries, Inc. regularly performs acoustical and fire (UL) testing to ensure performance standards for our products. Firm Fill® gypsum concretes, including Firm Fill® 3310 Classic, were tested acoustically with the following floor assemblies and performed as noted.

Related Products 30

Hacker Industries, Inc. | Architect Binder | FIRM-FILL® 3310 Classic | © 2017


OPEN WEB

Sound System 1: No Sound Mat, 3/4” (25 mm) FIRM-FILL® Brand Gypsum Concrete

SUBMITTAL FORM

Subfloor Topping

Sound Mat

3/4” None (25mm) FIRM-FILL® Brand Gypsum Concrete

Subfloor

3/4” (19 mm) oriented strand board

Subfloor topping: 3/4” (25 mm) FIRM-FILL® B Subfloor: 3/4” (19 mm) oriented strand board Insulation: 3-1/2” (89 mm) unfaced R-13 fiber Truss: 18” (457 mm) L/360 open web truss Ceiling isolation: Clark Dietrich RCSD resilient Ceiling: 5/8” (16 mm) type C gypsum board

FINISH Firm Fill® 3310+ – Open Web ¹ InsulationBareTruss Ceiling Ceiling Isolation Bare Carpet and Pad 3-1/2” Clark 18” (89 mm) Wood (457Laminate mm) Dietrich ² unfaced RCSD L/360 2 open mm Vinyl ³ R-13 resilient webSheet fiberglass truss channel insulation

5/8” (16 mm) type C gypsum board

STC Finish

Bare¹

IIC

REPORT #

54 Sound -Rating 51 -STC IIC 52 75

5005002 Report # D6435.29

54

--

D6435.30

5005002

Bare

--

51

52 7004018 -D6435.29

Carpet and Pad

--

52

75 54

D6435.30 7004025

--

52

7004018

Wood Laminate²

® 2 mmSubfloor Vinyl -- 1”54 7004025 ¹ Assembly varies from above in the following: topping: FIRM-FILL Brand Gypsum Sheet³ Subfloor: 23/32” oriented strand board; Insulation: None ® ® Brand ¹ Assembly varies from above in the following: Subfloor topping: 1”²FIRM-FILL Gypsum Concrete; oriented strand board; Insulation: None Assembly varies from aboveSubfloor: in the 23/32” following: Subfloor topping: 1” FIRM-FILL Brand Gypsum ² Assembly varies from above in the following: Subfloor topping: 1” FIRM-FILL® Brand Gypsum Concrete; Subfloor: 23/32” oriented strand board Subfloor: 23/32” oriented strand board ® ³ Assembly varies from above in the following: Subfloor topping: 1” FIRM-FILL Brand Gypsum Concrete; Subfloor: 23/32” oriented strand board; Insulation: 9” (229 mm) fiberglass batt insulation ³ Assembly varies from above in the following: Subfloor topping: 1” FIRM-FILL® Brand Acoust Gypsum Hacker Industries, Inc. Subfloor: 23/32” oriented strand board; Insulation: 9” (229 mm) fiberglass batt insulation

NOMINAL WOOD

UL Fire Rated Designs Sound System 2: FIRM-FILL® SCM-125, 3/4” (19 mm) FIRM-FILL® Brand Gypsum Concret Open Web L521, L528, L529, L534, L542, L546, L550, L558, L563, L574, L576, L577, L579, L583, L585, L592, M500, M503, M508 ® Subfloor topping:®3/4” (19Gypsum mm) FIRM-FILL Brand Concrete B Sound System 1: No Sound Mat, 3/4” (19 mm) FIRM-FILL ® Subfloor isolation: 1/8” (3 mm) FIRM-FILL SC Subfloor: (19 mm) board® Subfloor3/4” topping: 3/4” oriented (19 mm)strand FIRM-FILL Insulation: (89 mm) unfaced R-13board fiber Subfloor: 3-1/2” 3/4” (19 mm) oriented strand Truss: 18” (457 mm) L/360 truss in Insulation: 3-1/2” (89 mm)open R-13web fiberglass Ceiling Clark Dietrich RCSD resilient Joist: isolation: 9-1/4” (235 mm) 2x10 dimensional lum Ceiling: (16 mm) C gypsum Ceiling5/8” isolation: Clarktype Dietrich RCSDboard resilien Ceiling: 5/8” (16 mm) type C gypsum board FINISH

Subfloor Topping

Sound Mat

3/4” None (19 mm) FIRM-FILL® Brand Gypsum Concrete

Nominal Wood

STC

IIC

REPORT #

Bare 59 -D6435.01 STC IIC REPORT # FirmFINISH Fill® 3310+ – Nominal Wood 2 mm Vinyl Plank 60 51 D6435.02 56Sound-- Report E3149.01 Subfloor Insulation Bare Truss Ceiling Ceiling Finish 3 mm Vinyl TileIsolation 61 Rating 53 D6435.03 # Carpet and Pad 57 75 E3149.02 2 mm Vinyl Sheet 58STC IIC 51 D6435.04 Carpet and Pad¹ 51 76 E4054.01 Bare -E3149.01 3/4" 3-1/2" Clarkwith Rubber 5/8" Backing 7 9-1/4" mm Sheet Vinyl 5956 57 D6435.05 (19 mm) (89 mm) (235 mm) Dietrich (16 mm) Carpet and 57 75 E3149.02 oriented R-13 RCSD Woodtype C 132x10 mm Engineered 59 57 D6435.06 Pad strand fiberglass Resilient gypsum CarpetSubfloor and 51 1” 76(25E4054.01 from above in the following: topping: mm) FIRM-FILL® Bran board insulation ¹ Assembly varies Channel board Pad¹

These guidelines shall only be a resource and are not a guarantee of performance. FIRM-FILL® SCM Underlayments are only one compon acoustical performance is affected by every other component. The likelihood of achieving code compliance is contingent upon many other plumbers and drywall contractors. Developers and®general contractors are responsible for building properly ® and testing field performance as so UL Laboratory FireSystem Rated Designs Sound 2: FIRM-FILL SCM-125, (19 mm) Gypsum Concre of the project. tests are not a guarantee of field performance3/4” because of the issuesFIRM-FILL noted above andBrand many other design and/or cons a professional acoustical consultant assureL501, specifications written correctly and that the floor/ceiling assembly can perform to expectation L006, L201, L202, L206, L208, L209, L210, L211, toL212, L502,are L503, L504, L505, L506, L507, L508, L509, ® ® ensure reliability of design prior to occupancy. © 2/2016 Hacker Industries, Inc. FIRM-FILL , GYP-SPAN associated logos are the®re Subfloor topping: 3/4” and (19themm) FIRM-FILL

L510, L511, L512, L513, L514, L515, L516, L517, L519, L520, L522, L523, L525, L526, L532, L533, L535 , L536, L537, L540, L541, L545, L557, L569, L588, L590, L593, L598, M504, M517,Subfloor M519, M530, M531, M517 isolation: 1/8” (3 mm) FIRM-FILL® S

I-Joist L518, L530, L538, L547, L556, L570, L581, L589, M502, M506, M512

Hacker Industries, Inc. | Architect Binder | FIRM-FILL® 3310 Classic | © 2017

Subfloor: 3/4” (19 mm) oriented strand board 5 Insulation: 3-1/2” (89 mm) R-13 fiberglass in Joist: 9-1/4” (235 mm) 2x10 dimensional lum Ceiling isolation: Clark Dietrich RCSD resilien Ceiling: 5/8” (16 mm) type C gypsum board 31


Subfloor Topping 1-1/4” (32 mm) FIRM-FILL® Brand Gypsum Concrete

Sound Mat

Subfloor

3/8" 6" (10 mm) (152 mm) FIRM-FILL® concrete SCM-400 Sound Control Mat

6” (152 mm) CONCRETE ASSEMBLY

SUBMITTAL FORM

Sound System 3: FIRM-FILL® SCM-400, 1-1/4” (32 mm) FIRM-FILL® Brand Gypsum Conc

Subfloor topping: 1-1/4” (32 mm) FIRM-FILL Subfloor isolation: 3/8” (10 mm) FIRM-FILL® Subfloor: 6” (152 mm) concrete

FINISH ® 3310+ – Concrete Assembly Firm Fill InsulationBareTruss Ceiling Ceiling Isolation Bare

None

Sheet Vinyl None Bare

None

None

STC Finish

Bare Bare

IIC

REPORT #

52 Sound -5014051 Report Rating # -50 7014063 STC IIC -50 7014064 52 -- 5014051 -- -∆ 23*7014063 7014091 50

Sheet -- Method 50 7014064 *Tested in accordance with ASTM E2179 – Vinyl Standard Test for Laboratory Mea -- Through Δ 7014091 Floor Coverings in Reducing Impact Bare Sound Transmission Concrete Floors. 23*

*Tested in accordance with ASTM E2179 - Standard Test Method for Laboratory Measurement of Effectiveness of Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors.

Sound System 4: Hacker Sound Mat I, 3/4” (19 mm) FIRM-FILL® Brand Gypsum Concret UL Fire Rated Designs

Concrete J917, J919, J920, J924, J927, J931, J957, J991, J994

FIRM-FILL® SCM sound control mats, Hacker Floor Primer, Hacker TopCoat™ SP and Hacker Floor Sealer are available for use with FIRM-FILL® 3310 Classic. Contact Hacker Industries, Inc. at FINISH (800) 642-3455 f or info@hackerindustries.com or Bare more information.

Warranty

Bare

Subfloor topping: 3/4” (19 mm) FIRM-FILL® B Subfloor isolation: .08” (2 mm) Hacker Sound Subfloor: 6” (152 mm) concrete

Contributes points to LEED Submittal Approvals

®

Project Name

STC

IIC

REPORT #

53

--

5014076

--

∆ 15*

7014144

Contractor/Architect

certification

Signature

*Tested in accordance with ASTM E2179 – Standard Test Method for Laboratory Mea Subject to express warranty stated on Hacker Industries, Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors.

Inc.’s website.

Date

PRODUCT INFORMATION See www.HackerIndustries.com for current recommended product specifications and literature.

TRADEMARKS FIRM-FILL®, GYP-SPAN®, Let Our Products Floor You™ and the associated logos are trademarks of Hacker Industries, Inc. LEED® is a registered trademark of the U.S. Green Building Council.

WARNING When mixed with water, this product hardens and becomes extremely WARRANTY hot. DO NOT attempt to make a cast enclosing any part of the body using HACKER INDUSTRIES, INC. SHALL NOT BE LIABLE FOR INCIDENTAL this material. Failure to follow these instructions may cause severe burns OR CONSEQUENTIAL DAMAGES, DIRECTLY OR INDIRECTLY that may require surgical removal of affected tissue or amputation of limb. SUSTAINED, NOR FOR ANY LOSS CAUSED BY APPLICATION OF ® guidelines shall only THESE be a resource and are notIN a guarantee of performance. Underlayments are only one compo Portland cement is strongly alkaline. Direct contact can These be corrosive and GOODS NOT ACCORDANCE WITH FIRM-FILL CURRENTSCM PRINTED performance is affected by every other component. The likelihood of achieving code compliance is contingent upon many othe cause severe damage or chemical burns to eyes and wet,acoustical moist skin. Avoid INSTRUCTION OR FOR OTHER THAN THE INTENDED USE. OUR plumbers and drywall contractors. Developers and general contractors are responsible for building properly and testing field performance as s contact with eyes and skin. Wear protective glasses and clothing. If eye LIABILITY IS EXPRESSLY LIMITED TO REPLACEMENT OF DEFECTIVE of the project. Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or con contact occurs, immediately flush thoroughly with watera professional for 30 minutes GOODS. ANY CLAIM SHALL BE DEEMED WAIVED UNLESS MADE acoustical consultant to assure specifications are written correctly and that the floor/ceiling assembly can perform to expectati and seek medical advice. Inhalation of dust may be corrosive causeof design prior IN WRITING TO©US WITHIN DAYS FROM DATE ®IT WAS, OR ® ensureor reliability to occupancy. 2/2016 Hacker30 Industries, Inc. FIRM-FILL , GYP-SPAN and the associated logos are the chemical burns or irritation to nose, throat and respiratory tract. REASONABLY SHOULD HAVE BEEN, DISCOVERED. Avoid breathing dust. Use a NIOSH/MSHA-approved dust respirator. Wash thoroughly with soap and water after use. Do not ingest. If ingested, call a physician. Product safety, call (800) 642-3455. KEEP OUT OF REACH OF CHILDREN.

SAFETY FIRST 17during installation. Wear Follow good safety/industrial hygiene practices appropriate personal protective equipment. Read specs, MSDS and literature prior to specification and installation. © 2017 Hacker Industries, Inc., Newport Beach, CA.

32

Hacker Industries, Inc. | Architect Binder | FIRM-FILL® 3310 Classic | © 2017


RECOMMENDED SPECIFICATIONS PART I: GENERAL 1.1

Summary

A.

This section includes underlayment for interior finish flooring.

B.

Specify to meet project requirements. The conditions of the Contract (General, Supplementary, and other conditions) and the General Requirements (sections of Division 1) govern the provisions of this section.

C.

Related Sections:

1. Section 09 21 16 – Gypsum Board Assemblies

1.2

Referenced Standards

A.

The following standards and publications are applicable:

1. ASTM C472 Modified Standard Test Methods for Physical Testing of Gypsum, Gypsum Plasters, and Gypsum Cement (compressive strength)

2. ASTM C33 Standard Specification for Concrete Aggregates (sand aggregate)

3. ASTM D4263 Standard Test Method for Indicating Moisture in Concrete by the Plastic Sheet Method

4. ASTM E90 Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements

5. ASTM E119 Standard Test Methods for Fire Tests of Building Construction and Materials

6. ASTM E413 Rating Classification for Rating Sound Insulation

7. ASTM E492 Standard Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor-Ceiling Assemblies Using the Tapping Machine

8. ASTM F2419 Standard Practice for Installation of Thick Poured Gypsum Concrete and Preparation of the Surface to Receive Resilient Flooring

9. ASTM F2678 Standard Practice for Preparing Panel Underlayments, Thick Poured Gypsum Concrete Underlayments, Poured Lightweight Cellular Concrete Underlayments with Underlayment Patching Compounds to Receive Resilient Flooring

10. TCNA F180 Tile Council of North America Installation Handbook

11. NWFA National Wood Flooring Association Instructions

12. Hacker Industries, Inc. Installation Guide

13. Hacker Industries, Inc. Drying Conditions Flyer

14. Hacker Industries, Inc. Guidelines for Installing Finished Floor Coverings

15. UL Fire Resistance Directory

Hacker Industries, Inc. | Architect Binder | FIRM-FILL® 3310 Classic | © 2017

33


RECOMMENDED SPECIFICATIONS (CONT.)

1.3

Submittals

A.

Product Data: Submit manufacturer’s specifications and installation instructions with project conditions and materials clearly identified or detailed for each required product or system.

B.

Environmental Information: Submit product data for LEED® Credits MR 4 and MR 5, Recycled Content and Regional Materials. Provide documentation indicating percentages, by weight, of post-consumer and pre-consumer recycled content. Also provide documentation substantiating Regional Materials.

1.4

Quality Assurance

A.

Fire Resistance: Provide materials and construction identical to those tested according to ASTM E119 by an independent testing agency.

B.

Acoustical Performance: For STC: Provide materials and construction identical to those tested in assembly indicated according to ASTM E90 and classified according to ASTM E413 by an independent testing agency. For IIC: Provide materials and construction identical to those tested in assembly according to ASTM E492.

C.

Manufacturer: All materials, unless otherwise indicated, shall be manufactured by Hacker Industries, Inc., Newport Beach, California.

D.

Installer: Installation of FIRM-FILL® 3310 Classic Gypsum Concrete Floor Underlayment shall be by a Licensed Applicator of Hacker Industries, Inc., using mixing and pumping equipment with a water meter approved by Hacker Industries, Inc.

E.

Hacker Industries, Inc., Newport Beach, CA, shall approve all materials specified herein. All others must receive prior approval.

1.5

Performance Requirements

A.

1.6

Delivery, Storage And Handling

A.

1.7

Project Conditions

A.

1.8

Warranty

A.

Certification: Upon completion of this portion of the work, and as a condition of its acceptance, deliver to the architect a certificate from Hacker Industries, Inc., and signed by the Licensed Applicator, stating that the material used in this work complies with the specified requirements.

B.

Subject to express warranty as stated on Hacker Industries, Inc.’s website.

34

Compressive strength of FIRM-FILL® 3310 Classic Gypsum Concrete Floor Underlayment shall be from 3000 to 3900 psi (approx. 13.8 to 22.8 MPa)

Materials shall be delivered in their original, unopened packages and protected from exposure to the elements after delivery. Do not allow the bags to get wet.

Before, during and after installation of product, building interior shall be enclosed, with adequate ventilation and heat maintained at a temperature above 50°F (10°C) to allow for drying of product.

Hacker Industries, Inc. | Architect Binder | FIRM-FILL® 3310 Classic | © 2017


RECOMMENDED SPECIFICATIONS (CONT.)

PART II: PRODUCTS 2.1

Manufacturers

A.

Acceptable Manufacturers, subject to all the requirements contained herein: 1. Hacker Industries, Inc., Newport Beach, California

2.2

Material Description

A.

Gypsum Concrete: FIRM-FILL® 3310 Classic Gypsum Concrete Floor Underlayment, supplied by Hacker Industries, Inc.

B.

Subfloor Primer: Hacker Floor Primer or approved equal

C.

Sand: Washed plaster or masonry sand meeting the requirements of Hacker Industries, Inc. Sand Guidelines

D.

Water: Potable and free from impurities

E.

Sealer: Hacker TopCoat™ SP Surface Preparation Agent, if specified

PART III: EXECUTION 3.1

Examination

A.

Condition of Subfloor

1. Subfloor shall be structurally sound, broom cleaned, dry and free from oil, grease, paraffin, laitance or other contaminants before the arrival of the Hacker Licensed Applicator.

2. Wood Substrate:

a. Subfloor and framing must be designed to a maximum deflection of L/360.

b. Wood should be APA rated 23/32” (1.8 cm) T&G.

3. Concrete Substrate: shall be in place a minimum of 28 days.

4. Before installation, the General Contractor (GC) shall inspect and approve the condition of the subfloor and test for dryness.

3.2 Preparation

A.

Leak Prevention: All cracks and voids should be filled with a quick-setting patching or taping compound, or equal, where leakage may occur.

B.

Prime wood subfloors with one coat of Hacker Floor Primer (diluted 4:1 with water) using one gallon of primer solution (approx. 3.79 L) per 500 ft2 (approx. 47 m2). Hacker Floor Primer is not always required over concrete substrates. Multiple coats may be required over porous concrete or plank. (Note: For rehabilitation work or pours over old and/or porous concrete or wood, consult a Licensed Applicator or Hacker Industries, Inc. for recommended floor preparation.)

C.

Installation of FIRM-FILL® 3310 Classic Gypsum Concrete Floor Underlayment shall not begin until the building is enclosed, including roof, windows, doors, and other openings.

D.

FIRM-FILL® 3310 Classic Gypsum Concrete Floor Underlayment may be installed before or after the installation of drywall, as specified.

Hacker Industries, Inc. | Architect Binder | FIRM-FILL® 3310 Classic | © 2017

35


RECOMMENDED SPECIFICATIONS (CONT.)

3.3 Installation

A.

Mixing Instructions: Add 80-pound (36.3 kg) bag of FIRM-FILL® 3310 Classic to 6 to 7 gallons (22.7 to 26.5 L) of water followed by the specific sand ratio. Do not overwater. Water amount will vary with the wetness of the sand.

This is the proper sequence for mixing of FIRM-FILL® 3310 Classic.

First add water to bucket followed by FIRM-FILL® 3310 Classic and finally the sand.

B.

Application: The minimum thickness of FIRM-FILL® 3310 Classic Gypsum Concrete Floor Underlayment varies with the type of subfloor. Over wood subfloors, a minimum of 3/4” (approx. 19 mm) is required. Over precast or poured-in-place concrete, a minimum of 1/2” (approx. 13 mm) is required.

C.

FIRM-FILL® 3310 Classic Gypsum Concrete Floor Underlayment is suitable for interior applications only and must be covered by a finished floor material.

D.

Protection: After installation, the GC shall place temporary wood planking wherever the floor underlayment will be subject to wheeled or concentrated loads.

E.

Drying: Before, during and after installation of FIRM-FILL® 3310+ Gypsum Concrete Floor Underlayment, building interior must be ventilated and heated to a minimum 50°F (10°C) to ensure completion of the drying process. The GC shall provide continuous ventilation and adequate heat to rapidly remove moisture from the area until the FIRM-FILL® 3310+ Gypsum Concrete Floor Underlayment is dry. Do not install finished floor coverings until the FIRM-FILL® 3310+ Gypsum Concrete Floor Underlayment is tested for dryness. Consult flooring contractor for recommended procedures to test for dryness. Reference Hacker Industries, Inc.’s Drying Conditions Flyer.

F.

Field Quality Control:

1. Slump Test: FIRM-FILL® 3310+ Gypsum Concrete Floor Underlayment shall be tested for slump at the beginning of each installation in order to establish the required slump. Slump tests shall then be taken periodically during installation to verify that the required slump is maintained. Slump tests shall be conducted using a 2” by 4” (approx. 51 mm by 102 mm) cylinder. The acceptable patty size should be 8.5” (approx. 216 mm) plus or minus 1/2” (approx. 13 mm) in diameter. 2. Field Samples: Testing shall be done in accordance with ASTM C472 modified testing procedures, using 2” (approx. 51 mm) split brass molds. Prior to independent sampling, contact Hacker Industries, Inc., to ensure that proper ASTM procedures are followed. If requested prior to installation, test results shall be available to the architect and/or contractor from the Licensed Applicator. 3.4 Preparation For Finished Floor

A.

Repair any damaged areas of underlayment prior to application of any sealers.

B.

Underlayment must be dry prior to installation of finished floor. Follow ASTM D4263 to determine dryness of underlayment.

C.

Resilient Floor Applications: Follow floor covering manufacturer’s guidelines for proper applications and procedures (ASTM F2419).

D.

Install wood flooring according to NWFA Instructions.

E.

Install ceramic, porcelain, granite or natural stone tiles according to TCNA recommendations.

36

Hacker Industries, Inc. | Architect Binder | FIRM-FILL® 3310 Classic | © 2017


PROJECT REFERENCES Ideal over wood or concrete subfloors in multi-family, renovation projects and custom homes, FIRM-FILL® 3310+ helps maximize sound control and creates a flat, durable surface for finished floor coverings. FIRM-FILL® 3310+ offers an innovative formulation that decreases the amount of water used while enhancing the rock-solid floor strength, up to 3300 psi. Below is a small sample of projects that have utilized FIRM-FILL® 3310+. Contractor: Barnhill Contracting Project: West Village (Renovation) Location: Durham, North Carolina Description: 190,000 ft² of FIRM-FILL® 3310 over Hacker Sound Mat II Contractor: Bozzuto Construction Project: Jericho Senior Apartments Location: Landover, Maryland Description: 245,000 ft² of FIRM-FILL® 3310 Contractor: Coryell Enterprises Project: Orchard Park Apartments Location: Springfield, Missouri Description: 164,292 ft² of FIRM-FILL® 3310 Contractor: D.R. Horton Project: Grande at Riverdale Location: Riverdale, New Jersey Description: 350,000 ft² of FIRM-FILL® 3310 over Hacker Sound Mat II Contractor: Fairfield Development Project: Addison Residential Location: Addison, Texas Description: 354,351 ft² of FIRM-FILL® 3310 Contractor: HA Anderson Project: Meadow Lake Village Location: Meridian, Idaho Description: 148,000 ft² of FIRM-FILL® 3310 Contractor: Hy-Max Building Corporation Project: Halsted/Zelzah Apartments Location: Northridge, California Description: 20,180 ft² of FIRM-FILL® 3310 Contractor: LCG Pense Project: Bozeman Village Assisted Living Location: Bozeman, Montana Description: 76,000 ft² of FIRM-FILL® 3310 Contractor: Legacy Project: Coggins Drive Apartments / Vineyards Location: Pleasant Hill, California / Gilroy, California Description: Various projects with FIRM-FILL® 3310

Hacker Industries, Inc. | Architect Binder | FIRM-FILL® 3310 Classic | © 2017

37


FIRM-FILL® 3310+, a premium poured floor underlayment from Hacker Industries, Inc., delivers best in class performance with compressive strengths from 3000-3900 psi. Ideal over wood or concrete subfloors in multi-family, hospitality, and renovation projects, FIRM-FILL® 3310+ maximizes sound control and creates an enhanced surface for finished floor coverings. • Easy application, fast setting; light traffic can return within hours • Over 100 UL Fire Rated Design listings; ICC-ES Legacy Report • Can be poured before or after drywall, as specified • Specify with FIRM-FILL® SCM acoustical control mats for improved acoustical performance • Meets ASTM F2419 and Tile Council of North America F180, F200 • Installed by trained Licensed Applicators


1 - FLOOR COVERING / 2 - FIRM-FILL® 3310 GYPSUM CONCRETE UNDERLAYMENT / 3 - FIRM-FILL® SCM OR 6 - BATT INSULATION / 7 - PARALLEL CHORD TRUSS / 8 - TJI ® JOIST / 9 - RESILIENT CHANNEL / 10 - GYPSUM

i 00 ps 0-32 nt ® Rad®ia 200 1 - FLOOR COVERING / 2 - FIRM-FILL 3310 GYPSUM CONCRETE UNDERLAYMENT / 3 - FIRM-FILL SCM OR HA AN P S ® RM-FILL SCM OR HACKER SOUND MAT / 4 - PLYWOOD OR 6 OSB / 5 - INSULATION NOMINAL WOOD JOIST / P- BATT / 7 - PARALLEL CHORD TRUSS / 8 - TJI ® JOIST / 9 - RESILIENT CHANNEL / 10 - GYPSUM W GY NEL / 10 - GYPSUM WALLBOARD / 11 - 6” CONCRETE 2000-3300 psi ®

D M

2

mC onc ret e

1200200 0p FIRM s -FIL i Gypsu L®

F

2

si FIRM-FILL ® 0p ® 3310 20 L 3 IL 000 M-F 0+psi IR0-322001 psi nt ® Radia 200 nt PAN ® Radia SOSB mi ® ® 1 - FLOOR COVERING / 2 FIRM-FILL 3310+ CONCRETE UNDERLAYMENT / 3 FIRM-FILL SCM OR HACKER SOUND MAT / 4 PLYWOOD OR / P n. FIWOOD GY 5 - NOMINAL / 6 - BATT INSULATION / 7 - PARALLEL CHORD TRUSS / 8 - TJI ® JOIST / 9 - RESILIENT CHANNEL / 10 - GYPSUM WALLBOARD / 2000-3300 psi RM 35JOIST 00 11 6” CONCRETE 3 0 3 F 0 0 p 0 p s 0 i 2 IL s i s FIRM-FILL ® i L® p ® 25 ILLHACKER 00 ® IRM-FOR FILL®FSCM SOUND MATC/ 4 - PLYWOOD OR OSB / 5 - NOMINAL WOOD JOIST / 3310 0 2 0 L 3 0 psi 1000 psi 2000 psi 3000 psi 4000 psi 5000 psi 6000 psi IL 03310 FIR -3/8011 - 6” CONCRETE / 10 - GYPSUM WALLBOARD F 0 0 0 M 0+ Hig M-F p IR 201 hS I tre LL mC onc ret e

1200200 0p FIRM s -FIL i Gypsu L®

© 2017 Hacker Industries, Inc. FIRM-FILL® and the associated logos are trademarks of Hacker Industries, Inc., Newport Beach, CA.

4000-5200 psi

2000-3200 psi

Firm-Fill® CMD

3000-3900 psi

Gyp-Span Radiant

2000-3200 psi

2500-3800 psi

True-Screed CLU

up to 6000 psi

min. 3500 psi

2000-3300

3000-3900

psi 200 0-5 ® 400 ILL M-F FIR 010 4

psi 000 to 6 D® CLU up REE -SC UE TR

en g

Firm-Fill® 4010+

D M

a)

25 00 FIR -380 0 Hig M-F p hS IL tr L th

esom

p IL L ® si C

®

MPa)

.3

FI

50 M- Strength Firm-Fill® RHigh 0 F

1200-2000 psi

si

pres0 from

psi 000 to 6 D® CLU up REE -SC UE TR

mi Firm-Fill® 3310+ n

psi 200 0-5 ® 400 ILL M-F FIR 010 4

Firm-Fill® 2010+

2000-3300 psi FIRM-FILL ® 3310

00

®

th

diant

F

si

ng

Firm-Fill® Gypsum Concrete

High-strength for use over wood or concrete subfloors

UL for 1 to 2 hour fire ratings

Provides UL designIdeal listingsfor Fast installation & Provides Installedcompresby multifor High-strength compressive for 1 to 2 hour fire rapid set; walk on Hacker Industries' family construction wood or ratings over from strengths use strengths in 90 minutes sive trained Licensed from 3000-3900subfloors psi Applicatorspsi concrete 2000-3300 (20.6-26.8 MPa) (13.8-22.8.8 MPa)

Ideal for multiHigh-strength for Fast installation & Installed only by family construction use over wood or rapid set; walk on Hacker Industries’ concrete subfloors in 90 minutes L/360 Licensed Applicators

UL design listings for 1 to 2 hour fire ratings Requires dryin (building must be fully enclosed before design listings installation)

Ideal for multifamily construction

2000-3300

Not a wear surface; requires finished floor covering

Hacker Industries, Inc. |

Deflection must not exceed L/360 live or dead load

Subfloor must be protected by vapor barrier if installed above by onlyspace Installedcrawl

Provides compressive strengths from 2000-3300 psi (13.8-22.8.8 MPa)

One component of an effective sound & fire control system

Fast installation & on rapid set; walk Hacker Requires dry-in Industries’ Not a wear surface; in 90 minutes(building must Licensed be Applicators requires finished Architect Binder | Firm-Fill® 3310+ | © 2017 fully enclosed floor covering

UL for rati

UL de for 1 t rating

Wear appropriate personal protective equipment

Deflection must not exceed L/360 39 live or dead load

Su pro bar


SUBMITTAL FORM TECHNICAL DATA

PROPERTIES

ASTM

Weight

7.6 lb/ft² (37.1 kg/m²) at 3/4” (19 mm)

C472 M

Thickness

Wood: 3/4” (19 mm) to 3-1/2” (89 mm); Concrete: 1/2” (13 mm) to 3-1/2” (89 mm)

F2419

Compressive Strength

3000 to 3900 psi (20.6 to 26.8 MPa)

C472 M

Thermal Performance

K-value of 2.8 BTU/(hr.ft.F°); R-value of 0.36 (ft².hr.F°)

C177

Fire Hazard Classification

Flamespread index 0: Fuel contribution 0; Smoke density 0

E84

Sand

1/8” (3 mm) or less washed plaster or masonry sand

C33

Flexural Strength

1200 psi (8.27 MPa)

C348

Benefits • • • • • • • • •

High-strength underlayment for use over wood or concrete subfloors Install over a FIRM-FILL® SCM or Hacker Sound Mat for additional sound isolation Contributes to excellent STC and IIC ratings UL fire-rated designs for 1 to 3 hour fire ratings Lightweight and crack-resistant Reduced amount of water for accelerated drying time Contributes points to LEED® project certification Creates a flat, durable, non-structural underlayment surface for finished floor coverings Installed only by trained Licensed Applicators across North America

Product Description Specifically designed for new, thin laminates, this product’s rapid set time allows light foot traffic in 90 minutes. This versatile, high quality floor underlayment is widely used as an alternative to lightweight concrete in multi-family, light commercial and hospitality projects. FIRM-FILL® 3310+ provides compressive strengths from 3000 to 3900 psi (20.6 to 26.8 MPa). Depending on compressive strength, it can be installed before or after drywall. To help keep projects on schedule and on budget, Licensed Applicators can install over 25,000 ft² of FIRM-FILL® 3310+ in one day. FIRM-FILL® 3310+ is mixed on the job site with local sand (per ASTM C33) and water to create a lightweight slurry. Installed at a minimum of 3/4” thick, the underlayment weighs approximately 7.6 lb/ft² (37 kg/m²) with a dry density range of 107-120 pcf. For new construction, FIRM-FILL® 3310+ is a cost-efficient way to maximize sound control and create a smooth, flat and high-strength surface for finished floor coverings. To achieve additional sound isolation, use FIRMFILL® 3310+ with either a FIRM-FILL® SCM or Hacker Sound Mat.

Limitations • Do not use FIRM-FILL® 3310+ in exterior locations, below grade or where continuous exposure to moisture is likely. • Shall not be used as a wear surface; must be covered by a finished floor covering. • Structure shall be designed so that deflection does not exceed L/360 live or dead load. Certain floor coverings, such as marble, limestone, travertine and wood, may have more restrictive deflection limits. Consult the appropriate floor covering manufacturer for recommendations. • If installed above a crawl space, subfloor must be protected by a vapor barrier. • No single application of FIRM-FILL® 3310+ shall exceed 3” in depth. • FIRM-FILL® 3310+ is one component of an effective sound and fire control system. Care must be taken in the installation of all components to assure the ultimate design performance. Published acoustical and fire system tests were conducted under controlled laboratory or field conditions and reflect results applicable only to those specific assemblies. 40

Hacker Industries, Inc. | Architect Binder | Firm-Fill® 3310+ | © 2017


SUBMITTAL FORM Installation Before, during and after the installation of FIRM-FILL® 3310+, the building must be enclosed and the temperature maintained at a minimum of 50°F (10°C). Prior to the installation of FIRM-FILL® 3310+, the subfloor shall be structurally sound (L/360), broom cleaned, dry and free from oil, grease, paraffin, laitance, wax or other contaminants. Concrete subfloors shall be 28 days or older. For on-grade applications over concrete, measure the Moisture Vapor Emission Rate (MVER) per ASTM F1869. MVER shall not exceed 3 lb/1000 ft² per 24 hours. Prime wood subfloors with Hacker Floor Primer per recommended specifications before installing underlayment. Adequate ventilation shall be provided by the General Contractor (GC) to ensure proper drying of FIRMFILL® 3310+. If necessary, the GC shall provide mechanical ventilation. Depending on thickness and drying conditions, the underlayment should dry within 10 to 14 days. To avoid potential problems during the drying process, the GC shall consult Hacker Industries, Inc.’s Drying Conditions Flyer and information contained on Hacker Industries, Inc.’s website for additional information concerning drying of this product. After installation, temporary wood planking shall be placed by the GC wherever the floor underlayment will be subject to wheeled or concentrated loads. Finished floor coverings can be installed when the FIRM-FILL® 3310+ is completely dry. Consult flooring contractor for recommended procedures to test for dryness and acceptable levels of moisture. Reference Hacker Industries, Inc.’s Guidelines for Installing Finished Floor Coverings. This guideline is not a warranty and shall be used as a guideline only. See ASTM F2419.

Product Data Approximate Compressive Strength per ASTM C472 Modified: Approximate Dry Density (aggregated):

3000 to 3900 psi* (20.6 to 26.8 MPa) 107 to 120 pcf

*Note: Compressive strengths published herein were achieved under controlled laboratory conditions. Actual field results may differ due to environmental conditions, regional sand variations, or inconsistent proportioning of field-applied water, sand and Hacker Floor Underlayment, as well as differences in mixing/ pumping equipment.

Compliance • ICC-ES ER-4147 • City of Los Angeles Research Report No. 24540

• FHA-HUD MR 1255 • Tile Council of North America (F180, F200, RH111, RH122)

Sound Test & UL Fire Rated Designs PURPOSE STATEMENT/DISCLAIMER

These guidelines are designed to provide the architectural and building communities with detailed performance data on Hacker Industries, Inc.’s comprehensive portfolio of sound attenuation tests and UL Fire Rated Designs. The tests for the assemblies included in these guidelines were conducted in a laboratory setting per ASTM C177, E84, E90, E492 and E2179. These guidelines are not warranties and should be used as guidelines only. The architects’ and general contractors’ recommendations supersede these guidelines. Field performance may vary. Subject to express Warranty stated on Hacker Industries, Inc.’s website. Hacker Industries, Inc. regularly performs acoustical and fire (UL) testing to ensure performance standards for our products. Firm Fill® gypsum concretes, including Firm Fill® 3310+, were tested acoustically with the following floor assemblies and performed as noted.

Related Products Hacker Industries, Inc. | Architect Binder | Firm-Fill® 3310+ | © 2017

41


OPEN WEB

Sound System 1: No Sound Mat, 3/4” (25 mm) FIRM-FILL® Brand Gypsum Concrete

SUBMITTAL FORM

Subfloor Topping

Sound Mat

3/4” None (25mm) FIRM-FILL® Brand Gypsum Concrete

Subfloor

3/4” (19 mm) oriented strand board

Subfloor topping: 3/4” (25 mm) FIRM-FILL® B Subfloor: 3/4” (19 mm) oriented strand board Insulation: 3-1/2” (89 mm) unfaced R-13 fiber Truss: 18” (457 mm) L/360 open web truss Ceiling isolation: Clark Dietrich RCSD resilient Ceiling: 5/8” (16 mm) type C gypsum board

FINISH Firm Fill® 3310+ – Open Web ¹ InsulationBareTruss Ceiling Ceiling Isolation Bare Carpet and Pad 3-1/2” Clark 18” (89 mm) Wood (457Laminate mm) Dietrich ² unfaced RCSD L/360 2 open mm Vinyl ³ R-13 resilient webSheet fiberglass truss channel insulation

5/8” (16 mm) type C gypsum board

STC Finish

Bare¹

IIC

REPORT #

54 Sound -Rating 51 -STC IIC 52 75

5005002 Report # D6435.29

54

--

D6435.30

5005002

Bare

--

51

52 7004018 -D6435.29

Carpet and Pad

--

52

75 54

D6435.30 7004025

--

52

7004018

Wood Laminate²

® 2 mmSubfloor Vinyl -- 1”54 7004025 ¹ Assembly varies from above in the following: topping: FIRM-FILL Brand Gypsum Sheet³ Subfloor: 23/32” oriented strand board; Insulation: None ® ® Brand ¹ Assembly varies from above in the following: Subfloor topping: 1”²FIRM-FILL Gypsum Concrete; oriented strand board; Insulation: None Assembly varies from aboveSubfloor: in the 23/32” following: Subfloor topping: 1” FIRM-FILL Brand Gypsum ² Assembly varies from above in the following: Subfloor topping: 1” FIRM-FILL® Brand Gypsum Concrete; Subfloor: 23/32” oriented strand board Subfloor: 23/32” oriented strand board ® ³ Assembly varies from above in the following: Subfloor topping: 1” FIRM-FILL Brand Gypsum Concrete; Subfloor: 23/32” oriented strand board; Insulation: 9” (229 mm) fiberglass batt insulation ³ Assembly varies from above in the following: Subfloor topping: 1” FIRM-FILL® Brand Acoust Gypsum Hacker Industries, Inc. Subfloor: 23/32” oriented strand board; Insulation: 9” (229 mm) fiberglass batt insulation

NOMINAL WOOD

UL Fire Rated Designs Sound System 2: FIRM-FILL® SCM-125, 3/4” (19 mm) FIRM-FILL® Brand Gypsum Concret Open Web L521, L528, L529, L534, L542, L546, L550, L558, L563, L574, L576, L577, L579, L583, L585, L592, M500, M503, M508 ® Subfloor topping:®3/4” (19Gypsum mm) FIRM-FILL Brand Concrete B Sound System 1: No Sound Mat, 3/4” (19 mm) FIRM-FILL ® Subfloor isolation: 1/8” (3 mm) FIRM-FILL SC Subfloor: (19 mm) board® Subfloor3/4” topping: 3/4” oriented (19 mm)strand FIRM-FILL Insulation: (89 mm) unfaced R-13board fiber Subfloor: 3-1/2” 3/4” (19 mm) oriented strand Truss: 18” (457 mm) L/360 truss in Insulation: 3-1/2” (89 mm)open R-13web fiberglass Ceiling Clark Dietrich RCSD resilient Joist: isolation: 9-1/4” (235 mm) 2x10 dimensional lum Ceiling: (16 mm) C gypsum Ceiling5/8” isolation: Clarktype Dietrich RCSDboard resilien Ceiling: 5/8” (16 mm) type C gypsum board FINISH

Subfloor Topping

Sound Mat

3/4” None (19 mm) FIRM-FILL® Brand Gypsum Concrete

Nominal Wood

IIC

REPORT #

Bare 59 -D6435.01 STC IIC REPORT # FirmFINISH Fill® 3310+ – Nominal Wood 2 mm Vinyl Plank 60 51 D6435.02 56Sound-- Report E3149.01 Subfloor Insulation Bare Truss Ceiling Ceiling Finish 3 mm Vinyl TileIsolation 61 Rating 53 D6435.03 # Carpet and Pad 57 75 E3149.02 2 mm Vinyl Sheet 58STC IIC 51 D6435.04 Carpet and Pad¹ 51 76 E4054.01 Bare -E3149.01 3/4" 3-1/2" Clarkwith Rubber 5/8" Backing 7 9-1/4" mm Sheet Vinyl 5956 57 D6435.05 (19 mm) (89 mm) (235 mm) Dietrich (16 mm) Carpet and 57 75 E3149.02 oriented R-13 RCSD Woodtype C 132x10 mm Engineered 59 57 D6435.06 Pad strand fiberglass Resilient gypsum CarpetSubfloor and 51 1” 76(25E4054.01 from above in the following: topping: mm) FIRM-FILL® Bran board insulation ¹ Assembly varies Channel board Pad¹

These guidelines shall only be a resource and are not a guarantee of performance. FIRM-FILL® SCM Underlayments are only one compon acoustical performance is affected by every other component. The likelihood of achieving code compliance is contingent upon many other plumbers and drywall contractors. Developers and®general contractors are responsible for building properly ® and testing field performance as so UL Laboratory FireSystem Rated Designs Sound 2: FIRM-FILL SCM-125, (19 mm) Gypsum Concre of the project. tests are not a guarantee of field performance3/4” because of the issuesFIRM-FILL noted above andBrand many other design and/or cons a professional acoustical consultant assureL501, specifications written correctly and that the floor/ceiling assembly can perform to expectation L006, L201, L202, L206, L208, L209, L210, L211, toL212, L502,are L503, L504, L505, L506, L507, L508, L509, ® ® ensure reliability of design prior to occupancy. © 2/2016 Hacker Industries, Inc. FIRM-FILL , GYP-SPAN associated logos are the®re Subfloor topping: 3/4” and (19themm) FIRM-FILL

L510, L511, L512, L513, L514, L515, L516, L517, L519, L520, L522, L523, L525, L526, L532, L533, L535 , L536, L537, L540, L541, L545, L557, L569, L588, L590, L593, L598, M504, M517,Subfloor M519, M530, M531, M517 isolation: 1/8” (3 mm) FIRM-FILL® S

Subfloor: 3/4” (19 mm) oriented strand board 5 Insulation: 3-1/2” (89 mm) R-13 fiberglass in Joist: 9-1/4” (235 mm) 2x10 dimensional lum Ceiling isolation: Clark Dietrich RCSD resilien Ceiling: 5/8” (16 mm) type C gypsum board Hacker Industries, Inc. | Architect Binder | Firm-Fill® 3310+ | © 2017

I-Joist L518, L530, L538, L547, L556, L570, L581, L589, M502, M506, M512

42

STC


Subfloor Topping 1-1/4” (32 mm) FIRM-FILL® Brand Gypsum Concrete

Sound Mat

Subfloor

3/8" 6" (10 mm) (152 mm) FIRM-FILL® concrete SCM-400 Sound Control Mat

6” (152 mm) CONCRETE ASSEMBLY

SUBMITTAL FORM

Sound System 3: FIRM-FILL® SCM-400, 1-1/4” (32 mm) FIRM-FILL® Brand Gypsum Conc

Subfloor topping: 1-1/4” (32 mm) FIRM-FILL Subfloor isolation: 3/8” (10 mm) FIRM-FILL® Subfloor: 6” (152 mm) concrete

FINISH ® 3310+ – Concrete Assembly Firm Fill InsulationBareTruss Ceiling Ceiling Isolation Bare

None

Sheet Vinyl None Bare

None

None

STC Finish

Bare Bare

IIC

REPORT #

52 Sound -5014051 Report Rating # -50 7014063 STC IIC -50 7014064 52 -- 5014051 -- -∆ 23*7014063 7014091 50

Sheet -- Method 50 7014064 *Tested in accordance with ASTM E2179 – Vinyl Standard Test for Laboratory Mea -- Through Δ 7014091 Floor Coverings in Reducing Impact Bare Sound Transmission Concrete Floors. 23*

*Tested in accordance with ASTM E2179 - Standard Test Method for Laboratory Measurement of Effectiveness of Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors.

Sound System 4: Hacker Sound Mat I, 3/4” (19 mm) FIRM-FILL® Brand Gypsum Concret UL Fire Rated Designs

Concrete J917, J919, J920, J924, J927, J931, J957, J991, J994

FIRM-FILL® SCM sound control mats, Hacker Floor Primer, Hacker TopCoat™ SP and Hacker Floor Sealer are available for use with FIRM-FILL® 3310+. Contact Hacker Industries, Inc. at FINISH (800) 642-3455 f or info@hackerindustries.com or Bare more information.

Warranty

Bare

Subfloor topping: 3/4” (19 mm) FIRM-FILL® B Subfloor isolation: .08” (2 mm) Hacker Sound Subfloor: 6” (152 mm) concrete

Submittal Approvals

Contributes points to LEED® certification

STC IIC Project Name

53

--

5014076

--

∆ 15*

7014144

Contractor/Architect

REPORT #

Signature with ASTM E2179 – Standard Test Method for Laboratory Mea *Tested in accordance Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors. Subject to express warranty stated on Hacker Industries,

Inc.’s website.

PRODUCT INFORMATION See www.HackerIndustries.com for current recommended product specifications and literature.

Date

TRADEMARKS FIRM-FILL®, GYP-SPAN®, Let Our Products Floor You™ and the associated logos are trademarks of Hacker Industries, Inc. LEED® is a registered trademark of the U.S. Green Building Council.

WARNING When mixed with water, this product hardens and becomes extremely WARRANTY hot. DO NOT attempt to make a cast enclosing any part of the body using HACKER INDUSTRIES, INC. SHALL NOT BE LIABLE FOR INCIDENTAL this material. Failure to follow these instructions may cause severe burns OR CONSEQUENTIAL DAMAGES, DIRECTLY OR INDIRECTLY that may require surgical removal of affected tissue or amputation of limb. SUSTAINED, NOR FOR ANY LOSS CAUSED BY APPLICATION OF ® guidelines shall only THESE be a resource and are notIN a guarantee of performance. Underlayments are only one compo Portland cement is strongly alkaline. Direct contact can These be corrosive and GOODS NOT ACCORDANCE WITH FIRM-FILL CURRENTSCM PRINTED performance is affected by every other component. The likelihood of achieving code compliance is contingent upon many othe cause severe damage or chemical burns to eyes and wet,acoustical moist skin. Avoid INSTRUCTION OR FOR OTHER THAN THE INTENDED USE. OUR plumbers and drywall contractors. Developers and general contractors are responsible for building properly and testing field performance as s contact with eyes and skin. Wear protective glasses and clothing. If eye LIABILITY IS EXPRESSLY LIMITED TO REPLACEMENT OF DEFECTIVE of the project. Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or con contact occurs, immediately flush thoroughly with watera professional for 30 minutes GOODS. ANY CLAIM SHALL BE DEEMED WAIVED UNLESS MADE acoustical consultant to assure specifications are written correctly and that the floor/ceiling assembly can perform to expectati and seek medical advice. Inhalation of dust may be corrosive causeof design prior IN WRITING TO©US WITHIN DAYS FROM DATE ®IT WAS, OR ® ensureor reliability to occupancy. 2/2016 Hacker30 Industries, Inc. FIRM-FILL , GYP-SPAN and the associated logos are the chemical burns or irritation to nose, throat and respiratory tract. REASONABLY SHOULD HAVE BEEN, DISCOVERED. Avoid breathing dust. Use a NIOSH/MSHA-approved dust respirator. Wash thoroughly with soap and water after use. Do not ingest. If ingested, call a physician. Product safety, call (800) 642-3455. KEEP OUT OF REACH OF CHILDREN.

SAFETY FIRST 17during installation. Wear Follow good safety/industrial hygiene practices appropriate personal protective equipment. Read specs, MSDS and literature prior to specification and installation. © 2017 Hacker Industries, Inc., Newport Beach, CA.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® 3310+ | © 2017

43


RECOMMENDED SPECIFICATIONS PART I: GENERAL 1.1

Summary

A.

This section includes underlayment for interior finish flooring.

B.

Specify to meet project requirements. The conditions of the Contract (General, Supplementary, and other conditions) and the General Requirements (sections of Division 1) govern the provisions of this section.

C.

Related Sections:

1. Section 09 21 16 – Gypsum Board Assemblies

1.2

Referenced Standards

A.

The following standards and publications are applicable:

1. ASTM C472 Modified Standard Test Methods for Physical Testing of Gypsum, Gypsum Plasters, and Gypsum Cement (compressive strength)

2. ASTM C33 Standard Specification for Concrete Aggregates (sand aggregate)

3. ASTM D4263 Standard Test Method for Indicating Moisture in Concrete by the Plastic Sheet Method

4. ASTM E90 Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements

5. ASTM E119 Standard Test Methods for Fire Tests of Building Construction and Materials

6. ASTM E413 Rating Classification for Rating Sound Insulation

7. ASTM E492 Standard Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor-Ceiling Assemblies Using the Tapping Machine

8. ASTM F2419 Standard Practice for Installation of Thick Poured Gypsum Concrete and Preparation of the Surface to Receive Resilient Flooring

9. ASTM F2678 Standard Practice for Preparing Panel Underlayments, Thick Poured Gypsum Concrete Underlayments, Poured Lightweight Cellular Concrete Underlayments with Underlayment Patching Compounds to Receive Resilient Flooring

10. TCNA F180 Tile Council of North America Installation Handbook

11. NWFA National Wood Flooring Association Instructions

12. Hacker Industries, Inc. Installation Guide

13. Hacker Industries, Inc. Drying Conditions Flyer

14. Hacker Industries, Inc. Guidelines for Installing Finished Floor Coverings

15. UL Fire Resistance Directory

44

Hacker Industries, Inc. | Architect Binder | Firm-Fill® 3310+ | © 2017


RECOMMENDED SPECIFICATIONS (CONT.)

1.3

Submittals

A.

Product Data: Submit manufacturer’s specifications and installation instructions with project conditions and materials clearly identified or detailed for each required product or system.

B.

Environmental Information: Submit product data for LEED® Credits MR 4 and MR 5, Recycled Content and Regional Materials. Provide documentation indicating percentages, by weight, of post-consumer and pre-consumer recycled content. Also provide documentation substantiating Regional Materials.

1.4

Quality Assurance

A.

Fire Resistance: Provide materials and construction identical to those tested according to ASTM E119 by an independent testing agency.

B.

Acoustical Performance: For STC: Provide materials and construction identical to those tested in assembly indicated according to ASTM E90 and classified according to ASTM E413 by an independent testing agency. For IIC: Provide materials and construction identical to those tested in assembly according to ASTM E492.

C.

Manufacturer: All materials, unless otherwise indicated, shall be manufactured by Hacker Industries, Inc., Newport Beach, California.

D.

Installer: Installation of FIRM-FILL® 3310+ Gypsum Concrete Floor Underlayment shall be by a Licensed Applicator of Hacker Industries, Inc., using mixing and pumping equipment with a water meter approved by Hacker Industries, Inc.

E.

Hacker Industries, Inc., Newport Beach, CA, shall approve all materials specified herein. All others must receive prior approval.

1.5

Performance Requirements

A.

1.6

Delivery, Storage And Handling

A.

1.7

Project Conditions

A.

1.8

Warranty

A.

Certification: Upon completion of this portion of the work, and as a condition of its acceptance, deliver to the architect a certificate from Hacker Industries, Inc., and signed by the Licensed Applicator, stating that the material used in this work complies with the specified requirements.

B.

Subject to express warranty as stated on Hacker Industries, Inc.’s website.

Compressive strength of FIRM-FILL® 3310+ Gypsum Concrete Floor Underlayment shall be from 3000 to 3900 psi (approx. 20.6 to 26.8 MPa)

Materials shall be delivered in their original, unopened packages and protected from exposure to the elements after delivery. Do not allow the bags to get wet.

Before, during and after installation of product, building interior shall be enclosed, with adequate ventilation and heat maintained at a temperature above 50°F (10°C) to allow for drying of product.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® 3310+ | © 2017

45


RECOMMENDED SPECIFICATIONS (CONT.)

PART II: PRODUCTS 2.1

Manufacturers

A.

Acceptable Manufacturers, subject to all the requirements contained herein: 1. Hacker Industries, Inc., Newport Beach, California

2.2

Material Description

A.

Gypsum Concrete: FIRM-FILL® 3310+ Gypsum Concrete Floor Underlayment, supplied by Hacker Industries, Inc.

B.

Subfloor Primer: Hacker Floor Primer or approved equal

C.

Sand: Washed plaster or masonry sand meeting the requirements of Hacker Industries, Inc. Sand Guidelines

D.

Water: Potable and free from impurities

E.

Sealer: Hacker TopCoat™ SP Surface Preparation Agent, if specified

PART III: EXECUTION 3.1

Examination

A.

Condition of Subfloor

1. Subfloor shall be structurally sound, broom cleaned, dry and free from oil, grease, paraffin, laitance or other contaminants before the arrival of the Hacker Licensed Applicator.

2. Wood Substrate:

a. Subfloor and framing must be designed to a maximum deflection of L/360.

b. Wood should be APA rated 23/32” (1.8 cm) T&G.

3. Concrete Substrate: shall be in place a minimum of 28 days.

4. Before installation, the General Contractor (GC) shall inspect and approve the condition of the subfloor and test for dryness.

3.2 Preparation

A.

Leak Prevention: All cracks and voids should be filled with a quick-setting patching or taping compound, or equal, where leakage may occur.

B.

Prime wood subfloors with one coat of Hacker Floor Primer (diluted 4:1 with water) using one gallon of primer solution (approx. 3.79 L) per 500 ft2 (approx. 47 m2). Hacker Floor Primer is not always required over concrete substrates. Multiple coats may be required over porous concrete or plank. (Note: For rehabilitation work or pours over old and/or porous concrete or wood, consult a Licensed Applicator or Hacker Industries, Inc. for recommended floor preparation.)

C.

Installation of FIRM-FILL® 3310+ Gypsum Concrete Floor Underlayment shall not begin until the building is enclosed, including roof, windows, doors, and other openings.

D.

FIRM-FILL® 3310+ Gypsum Concrete Floor Underlayment may be installed before or after the installation of drywall, as specified.

46

Hacker Industries, Inc. | Architect Binder | Firm-Fill® 3310+ | © 2017


RECOMMENDED SPECIFICATIONS (CONT.)

3.3 Installation

A.

Mixing Instructions: Add 80-pound (36.3 kg) bag of FIRM-FILL® 3310+ to 6 to 7 gallons (22.7 to 26.5 L) of water followed by the specific sand ratio. Do not overwater. Water amount will vary with the wetness of the sand.

This is the proper sequence for mixing of FIRM-FILL® 3310+.

First add water to bucket followed by FIRM-FILL® 3310+ and finally the sand.

B.

Application: The minimum thickness of FIRM-FILL® 3310+ Gypsum Concrete Floor Underlayment varies with the type of subfloor. Over wood subfloors, a minimum of 3/4” (approx. 19 mm) is required. Over precast or poured-in-place concrete, a minimum of 1/2” (approx. 13 mm) is required.

C.

FIRM-FILL® 3310+ Gypsum Concrete Floor Underlayment is suitable for interior applications only and must be covered by a finished floor material.

D.

Protection: After installation, the GC shall place temporary wood planking wherever the floor underlayment will be subject to wheeled or concentrated loads.

E.

Drying: Before, during and after installation of FIRM-FILL® 3310+ Gypsum Concrete Floor Underlayment, building interior must be ventilated and heated to a minimum 50°F (10°C) to ensure completion of the drying process. The GC shall provide continuous ventilation and adequate heat to rapidly remove moisture from the area until the FIRM-FILL® 3310+ Gypsum Concrete Floor Underlayment is dry. Do not install finished floor coverings until the FIRM-FILL® 3310+ Gypsum Concrete Floor Underlayment is tested for dryness. Consult flooring contractor for recommended procedures to test for dryness. Reference Hacker Industries, Inc.’s Drying Conditions Flyer.

F.

Field Quality Control:

1. Slump Test: FIRM-FILL® 3310+ Gypsum Concrete Floor Underlayment shall be tested for slump at the beginning of each installation in order to establish the required slump. Slump tests shall then be taken periodically during installation to verify that the required slump is maintained. Slump tests shall be conducted using a 2” by 4” (approx. 51 mm by 102 mm) cylinder. The acceptable patty size should be 8.5” (approx. 216 mm) plus or minus 1/2” (approx. 13 mm) in diameter. 2. Field Samples: Testing shall be done in accordance with ASTM C472 modified testing procedures, using 2” (approx. 51 mm) split brass molds. Prior to independent sampling, contact Hacker Industries, Inc., to ensure that proper ASTM procedures are followed. If requested prior to installation, test results shall be available to the architect and/or contractor from the Licensed Applicator. 3.4 Preparation For Finished Floor

A.

Repair any damaged areas of underlayment prior to application of any sealers.

B.

Underlayment must be dry prior to installation of finished floor. Follow ASTM D4263 to determine dryness of underlayment.

C.

Resilient Floor Applications: Follow floor covering manufacturer’s guidelines for proper applications and procedures (ASTM F2419).

D.

Install wood flooring according to NWFA Instructions.

E.

Install ceramic, porcelain, granite or natural stone tiles according to TCNA recommendations.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® 3310+ | © 2017

47


PROJECT REFERENCES Ideal over wood or concrete subfloors in multi-family, renovation projects and custom homes, FIRM-FILL® 3310+ helps maximize sound control and creates a flat, durable surface for finished floor coverings. FIRM-FILL® 3310+ offers an innovative formulation that decreases the amount of water used while enhancing the rock-solid floor strength, up to 3300 psi. Below is a small sample of projects that have utilized FIRM-FILL® 3310+. Contractor: Esterline Construction Inc. Project: Carlton @ Bartram Park Location: Jacksonville, FL Description: 535,000 ft² of FIRM-FILL® 3310+ Contractor: Hathaway Development Corp Project: Ansley @ Overlook Location: San Antonio, TX Description: 300,000 ft² of FIRM-FILL® 3310+ Contractor: Vandervert Construction, Inc. Project: Hilton Garden Inn Location: Bellevue, WA Description: 82,800 ft² of FIRM-FILL® 3310+ Contractor: W.L. Butler Construction Project: 777 Hamilton Location: Menlo Park, CA Description: 126,566 ft² of FRIM-FILL® 3310+ Contractor: Wood Partners Project: 33 Peachtree Location: Atlanta, GA Description: 420,000 ft² of FIRM-FILL® 3310+

48

Hacker Industries, Inc. | Architect Binder | Firm-Fill® 3310+ | © 2017


From leveling a small office to resurfacing an entire commercial building, FIRM-FILL® HIGH STRENGTH is a cost-effective solution for correcting damaged, uneven or cracked concrete. From a featheredge to 3½”, FIRM-FILL® HIGH STRENGTH provides exceptional surface hardness with compressive strengths up to 3800 psi. • Over 100 UL Fire Rated Design Listings; ICC-ES Legacy Report • May be poured either before or after drywall • Rapid and efficient installation; sets in 90 minutes • Strong, crack-resistant surface for finished floor coverings • Installed by trained Licensed Applicators


1 - FLOOR COVERING / 2 - FIRM-FILL® HIGH STRENGTH GYPSUM CONCRETE UNDERLAYMENT / 3 - FIRM-FIL 6 - BATT INSULATION / 7 - PARALLEL CHORD TRUSS / 8 - TJI ® JOIST / 9 - RESILIENT CHANNEL / 10 - GYPSUM

F

2

i 00 ps 0-32 nt ® Radia 200 AN -SP P GY 2000-3300 psi ® ® i M LL® HIGH STRENGTH GYPSUM CONCRETE UNDERLAYMENT 1 -/ FLOOR 3 - FIRM-FILL COVERING SCM/OR 2 - FIRM-FILL HACKER SOUND HIGH STRENGTH MAT / 4 - PLYWOOD GYPSUMOR CONCRETE OSB / 5 - NOMINAL UNDERLAYMENT WOOD JOIST / 3I-RFIRM-FILL / -FILL ® ® F ps 00 ® L CHORD TRUSS / 8 - TJI ® JOIST / 9 - RESILIENT CHANNEL 6/ 10 - BATT INSULATION / 7 - PARALLEL CHORD TRUSS / 8 - TJI ® JOIST / 9 - RESILIENT 2CHANNEL - GYPSUM WALLBOARD / 11 - 6” CONCRETE / 10 - GYPSUM W 310 3 L 3 IL 000 M-F 0+ IR 201

mC onc ret e

2500-3800

i ps

00 ® L 32 IL 00 -F + 0 min. 3500 psi IRM 010 2

2000-3300 psi FIRM-FILL ® 3310

F

2

4000-5200 psi

6000 psi

Gyp-Span Radiant

2000-3200 psi

True-Screed CLU

up to 6000 psi

2500-3800

mC onc ret e

2

F

1200200 0p FIRM s -FIL i Gypsu L®

2500-3800 psi

PAN P-S Y G

5000 psi

si

psi 200 0-5 ® 400 ILL M-F FIR 010 4

psi 000 to 6 D® CLU up REE -SC UE TR

ng

th

© 2017 Hacker Industries, Inc. FIRM-FILL® and the associated logos are trademarks of Hacker Industries, Inc., Newport Beach, CA.

3000-3900 psi

Firm-Fill® CMD psi 000 to 6 D® CLU up REE -SC UE TR

ng

Firm-Fill® 4010+

psi 200 0-5 ® 400 ILL M-F FIR 010 4

50 RM 0 -F p IL L ® si 25 C 00 FIR -380 0 Hig M-F p hS IL tre L

C

D M

® in. Strength Firm-Fill FI High 3

-F M 10+ psi IR 2000-3200 20

th

Firm-Fill® 3310+ m

00

®

25 00 FIR -380 0 M Hig p h S FIL tre L

si

Firm-Fill® 2010+

®

0

L Firm-Fill® Gypsum Concrete0-32 1200-2000 psi IL

D M

2000-3300 psi FIRM-FILL ® 3310

FIRM-FILL ® 3310

®

ant

00

i ps

4000 psi

mC onc ret e

mi n. 3

FI

1200200 0p FIRM s -FIL i Gypsu L®

AN -SP

0 psi® 1000 psi 2000 psi 3000 50 JOIST / RMpsi P T / 3 - FIRM-FILL SCM OR HACKER SOUND MAT OR OSB / 5 - NOMINAL 0 GY / 4 - PLYWOOD -WOOD FI 000-3300 psi 2 LL psi 10 - GYPSUM WALLBOARD / 11 - 6” CONCRETE ®

1200200 0p FIRM s -FIL i Gypsu L®

1 - FLOOR COVERING / 2 - FIRM-FILL® HIGH STRENGTH GYPSUM CONCRETE UNDERLAYMENT / 3 - FIRM-FILL® SCM OR HACKER SOUND MAT / si 4 - PLYWOOD OR OSB / 5 - NOMINAL WOOD / 6 - BATT INSULATION / 7 - PARALLEL CHORD TRUSS / 8 - TJI ® JOIST / 9 - RESILIENT CHANNEL /00 psi 0 pJOIST 320 0-32 000 10 - GYPSUM WALLBOARD / 11 - 6”20CONCRETE t n nt a 0 i d ® Ra ® Radia 2

Ideal for light Provides Integral part of Contributes Installed only by 2500-3800 commercial, compressive solu100 UL Ideal fire rated Hacker Industries' for lightpoints com-to 2500-3800 compresCost-effective Provides

Cost-effective solution for damaged, uneven or cracked concrete

renovation and repair projects

strengths from listings LEED® project renovation for damaged,designmercial, tion 2500 - 3800 psi certification and repair projects cracked or MPa) uneven (17.2 - 26.2

concrete

trained Licensed strengths from sive Applicators

2500 - 3800 psi (17.2 - 26.2 MPa)

Inte UL d

L/360 part deal for light comIntegral Ideal for Contributes light com-points solu-of 100 only by Integr compresInstalled Cost-effective Provides compresProvides ® mercial, renovation sive strengths from ULdamaged, design listings mercial, to LEED renovation projectsive strengths from UL de Hacker Industries’ tion for Requires dryNot a wear Deflection must Subfloor must One component Wear appropriate and repair projects and repair projects certification - 3800 psiApplicators 2500 - 3800 psi uneven or cracked 2500 Licensed in (building surface; requires not exceed L/360 be protected by of an effective personal MPa) 26.2 26.2 MPa) -protective concrete (17.2 (17.2 must be fully finished floor live or dead load vapor barrier if sound & fire

sm

)

enclosed before installation)

Integral part of 100 UL design listings 50

covering

installed above crawl space

control system

equipment

Contributes points Installed only by ® Requires dry-in Not a wear surface; Deflection must to LEED project Hacker Industries’ (building must be not exceed L/360 requires finished certification Licensed Applicators Hacker Industries, Inc. | Architect Binder | Firm-Fill® High Strength | © 2017 fully enclosed live or dead load floor covering

Sub prot barr


SUBMITTAL FORM TECHNICAL DATA Weight Thickness Compressive Strength Thermal Performance Fire Hazard Classification Sand

PROPERTIES 7.7 lb/ft² (37.6 kg/m²) at 3/4” (19 mm) Featheredge in transition areas to 3-1/2” (89 mm) 2500 to 3800 psi (17.2 to 26.2 MPa) K-value of 3.34 BTU/(hr.ft.F°); R-value of 0.30 (ft².hr.F°) Flamespread index 0: Fuel contribution 0; Smoke density 0 1/8” (3 mm) or less washed plaster or masonry sand

ASTM C472 M F2419 C472 M C177 E84 C33

Benefits • • • • • • • •

Cost-effective way to correct damaged, uneven concrete subfloors Integral part of over 100 UL fire rated design listings Lightweight and crack-resistant Ideal for light commercial, renovation and repair projects Little shot blasting or surface preparation required Helps contribute points to LEED® project certification Creates a flat, durable, non-structural underlayment surface for finished floor coverings Installed only by trained Licensed Applicators across North America

Product Description FIRM-FILL® High Strength is designed to repair and resurface cracked, damaged and out-of-level concrete subfloors in renovation and repair projects. FIRM-FILL® High Strength sets in 90 minutes and is suitable for light foot traffic the following day. Installed from featheredge to 3-1/2”, FIRM-FILL® High Strength provides exceptional strength and durability. FIRM-FILL® High Strength provides compressive strengths from 2500 to 3800 psi (17.2 to 26.2 MPa). FIRM-FILL® High Strength is mixed on the job site with local sand (per ASTM C33) and water to create a lightweight slurry. At 3/4” (19 mm) thick, the underlayment weighs approximately 7.7 lb/ft² (37.6 kg/m²) with a dry density range of 120-125 pcf. For new construction or renovation, FIRM-FILL® High Strength provides a cost-efficient way to create a fireresistant, sound-rated and smooth floor surface. FIRM-FILL® High Strength is suitable for a variety of finished floor coverings. For additional sound control, specify FIRM-FILL® High Strength with a FIRM-FILL® SCM or Hacker Sound Control Mat.

Limitations • Shall not be used in exterior locations, below grade or where continuous exposure to moisture is likely. • Shall not be used as a wear surface; must be covered by a finished floor covering. • Structure shall be designed so that deflection does not exceed L/360 live or dead load. Certain floor coverings, such as marble, limestone, travertine and wood, may have more restrictive deflection limits. Consult the appropriate floor covering manufacturer for recommendations. • If installed above a crawl space, subfloor must be protected by a vapor barrier. • No single application of FIRM-FILL® High Strength shall exceed 3-1/2” (89 mm) in depth. • FIRM-FILL® High Strength is one component of an effective sound and fire control system. Care must be taken in the installation of all components to assure the ultimate design performance. Published acoustical and fire system tests were conducted under controlled laboratory or field conditions and reflect results applicable only to those specific assemblies.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® High Strength | © 2017

51


SUBMITTAL FORM Installation Before, during and after the installation of FIRM-FILL® High Strength, the building must be enclosed and the temperature maintained at a minimum of 50°F (10°C). Prior to the installation of FIRM-FILL® High Strength, the subfloor shall be structurally sound (L/360), broom cleaned, dry and free from oil, grease, paraffin, laitance, wax or other contaminants. Concrete subfloors shall be 28 days or older. For on-grade applications over concrete, measure the Moisture VaporEmission Rate (MVER) per ASTM F1869. MVER shall not exceed 3 lb/1000 ft² per 24 hours. If required, prime concrete subfloors with Hacker Floor Primer per recommended specifications before installing underlayment. Multiple coats may be required. Adequate ventilation shall be provided by the General Contractor (GC) to ensure proper drying of FIRM-FILL® High Strength. If necessary, the GC shall provide mechanical ventilation. Depending on thickness and drying conditions, the underlayment should dry within 7 to 10 days. To avoid potential problems during the drying process, the GC shall consult Hacker Industries, Inc.’s Drying Conditions Flyer and information contained on Hacker Industries, Inc.’s website for additional information concerning drying of this product. After installation, temporary wood planking shall be placed by the GC wherever the floor underlayment will be subject to wheeled or concentrated loads. Finished floor coverings can be installed when the FIRM-FILL® High Strength is completely dry. Consult flooring contractor for recommended procedures to test for dryness and acceptable levels of moisture. Reference Hacker Industries, Inc.’s Guidelines for Installing Finished Floor Coverings. This guideline is not a warranty and shall be used as a guideline only. See ASTM F2419.

Product Data Approximate Compressive Strength per ASTM C472 Modified: Approximate Dry Density (aggregated):

2500 to 3800 psi* (17.2 to 26.2 MPa) 120 to 125 pcf

*Note: Compressive strengths published herein were achieved under controlled laboratory conditions. Actual field results may differ due to environmental conditions, regional sand variations, or inconsistent proportioning of field applied water, sand and Hacker Floor Underlayment, as well as differences in mixing/pumping equipment.

Compliance • ICC-ES ER-4147 • City of Los Angeles Research Report No. 24540

• FHA-HUD MR 1255 • Tile Council of North America (F180, F200, RH111, RH122)

Sound Test & UL Fire Rated Designs PURPOSE STATEMENT/DISCLAIMER These guidelines are designed to provide the architectural and building communities with detailed performance data on Hacker Industries, Inc.’s comprehensive portfolio of sound attenuation tests and UL Fire Rated Designs. The tests for the assemblies included in these guidelines were conducted in a laboratory setting per ASTM C177, E84, E90, E492 and E2179. These guidelines are not warranties and should be used as guidelines only. The architect’s and general contractor’s recommendations supersede these guidelines. Field performance may vary. Subject to express Warranty stated on Hacker Industries, Inc.’s website. Hacker Industries, Inc. regularly performs acoustical and fire (UL) testing to ensure performance standards for our products. Firm-Fill® gypsum concretes, including Firm-Fill® High Strength, were tested acoustically with the following floor assemblies and performed as noted.

52

Hacker Industries, Inc. | Architect Binder | Firm-Fill® High Strength | © 2017


*Tested in accordance with ASTM E2179 – Standard Test Method for Laboratory Measu Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors.

Sound System 4: Hacker Sound Mat I, 3/4” (19 mm) FIRM-FILL® Brand Gypsum Concrete

SUBMITTAL FORM

Subfloor topping: 3/4” (19 mm) FIRM-FILL® Bra Subfloor isolation: .08” (2 mm) Hacker Sound M Subfloor: 6” (152 mm) concrete Contributes points to LEED® certification

Firm-FIllFINISH High Strength – Concrete Assembly 1 Subfloor Topping 3/4” (19 mm) FIRM-FILL® Brand Gypsum Concrete

Sound Mat .08" (2 mm) Hacker Sound Mat I

Subfloor

Insulation Bare Truss Bare

6" (152 mm) concrete

None

Ceiling Isolation

Ceiling

STC Finish

IIC

REPORT #

# 53Sound-- Report 5014076 Rating -∆ 15* 7014144 STC IIC

None None None Bare 53 -5014076 *Tested in accordance with ASTM E2179 – Standard Test Method for Laboratory Measu 15* 7014144 Bare Transmission -- ΔThrough Floor Coverings in Reducing Impact Sound Concrete Floors.

Contributes points to LEED® certification.

Hacker Industries, Inc.Hacker Industries, Inc.

Acoustic

UL Fire Rated Designs

Steel Deck G230, G516, G524, G553, G561, G565, G566, G568, G587, G594, G595 Steel Joist L524, L527, L539, L543, L549, L551, L552, L564, M505, M511, M513, M515, M534 6” (152 mm) CONCRETE ASSEMBLY

System FIRM-FILL® SCM-125, 3/4” (19 mm) FIRM-FILL® Brand Gypsum Concret J931, J957, J991,1: J994 Concrete J917, J919, J920, J924, J927,Sound

Subfloor Topping 3/4” (19 mm) FIRM-FILL® Brand Gypsum Concrete

Sound Mat

Subfloor topping: 3/4” (19 mm) FIRM-FILL® B

These guidelines shall only be a resource and are not a guarantee of performance. FIRM-FILL® SCM Underlayments are only one componen ® Subfloor isolation: 1/8” (3is contingent mm) FIRM-FILL acoustical performance is affected by every other component. The likelihood of achieving code compliance upon many otherSC tra plumbers and drywall contractors. Developers and general contractors are responsible for building properly and testing field performance as soon Subfloor: 6” (152 mm) concrete of the project. Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or constru a professional acoustical consultant to assure specifications are written correctly and that the floor/ceiling assembly can perform to expectations. ensure reliability of design prior to occupancy. © 2/2016 Hacker Industries, Inc. FIRM-FILL®, GYP-SPAN® and the associated logos are the regi

FINISH Firm-FIll High Strength – Concrete Assembly 2 Subfloor InsulationBareTruss Ceiling Ceiling Finish Isolation Bare

1/8" 6" (3 mm) (152 mm) FIRM-FILL® concrete SCM-125 Sound Control Mat

None

None

None

None

Bare

17

STC

IIC

REPORT #

51 5014050 Sound -- Report # Rating -∆ 20* 7014090 STC IIC 51

5014050

--

-- Δ 20*® Brand 7014090 Sound System 2: FIRM-FILL® SCM-250,Bare 1” (25 mm) FIRM-FILL Gypsum Concrete

Subfloor topping: 1” (25) mm FIRM-FILL® Bra Subfloor isolation: 1/4” (6 mm) FIRM-FILL® SC Subfloor: 6” (152 mm) concrete UL Fire Rated Designs

Steel Deck G230, G516, G524, G553, G561, G565, G566, G568, G587, G594, G595 L551, L552, L564, M505, M511, M513, M515, M534 FINISH Steel Joist L524, L527, L539, L543, L549, J931, J957, J991, J994 Concrete J917, J919, J920, J924, J927, Bare

Bare

STC

IIC

REPORT #

51

--

5014075

--

∆ 20*

7014143

*Tested in accordance with ASTM E2179 - Standard Test Method for Laboratory Measurement of Effectiveness of Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® High Strength | © 2017

53


Sound System 2: FIRM-FILL® SCM-250, 1” (25 mm) FIRM-FILL® Brand Gypsum Concrete

SUBMITTAL FORM

Subfloor topping: 1” (25) mm FIRM-FILL® Bran Subfloor isolation: 1/4” (6 mm) FIRM-FILL® SCM Subfloor: 6” (152 mm) concrete

Firm-FIll FINISH High Strength – Concrete Assembly 3 Subfloor Topping 1” (25 mm) FIRM-FILL® Brand Gypsum Concrete

Sound Mat

Subfloor Insulation Bare Truss Bare

1/4" 6" (6 mm) (152 mm) FIRM-FILL® concrete SCM-250 Sound Control Mat

None

None

Ceiling Isolation None

Ceiling

None

STC Finish

IIC

REPORT #

# 51Sound-- Report 5014075 Rating -∆ 20* 7014143 STC IIC

Bare

51

--

5014075

Bare

--

Δ 20*

7014143

UL Fire Rated Designs

Hacker Industries, Inc. G561, G565, G566, G568, G587, G594, G595 Steel Deck G230, G516, G524, G553,

Acoust

Steel Joist L524, L527, L539, L543, L549, L551, L552, L564, M505, M511, M513, M515, M534

6” (152 mm) CONCRETE ASSEMBLY

Concrete J917, J919, J920, J924, J927, J931, J957, J991, J994

Subfloor Topping

Sound Mat

Subfloor

Sound System 3: FIRM-FILL® SCM-400, 1-1/4” (32 mm) FIRM-FILL® Brand Gypsum Conc

Subfloor topping: 1-1/4” (32 mm) FIRM-FILL Subfloor isolation: 3/8” (10 mm) FIRM-FILL® Subfloor: 6” (152 mm) concrete

These guidelines shall only be a resource and are not a guarantee of performance. FIRM-FILL® SCM Underlayments are only one compone acoustical performance is affected by every other component. The likelihood of achieving code compliance is contingent upon many other tr plumbers and drywall contractors. Developers and general contractors are responsible for building properly and testing field performance as soo Firm-FIll Strength Assembly 4 because of the issues FINISH STC IICand many REPORT of the High project. Laboratory tests – areConcrete not a guarantee of field performance noted above other design # and/or constr a professional acoustical consultant to assure specifications are written correctly and that the floor/ceiling assembly can perform to expectations Insulation Truss Ceiling Ceiling Finish Sound Report # ® Bare of design prior to occupancy. © 2/2016 Hacker Industries, Inc. FIRM-FILL 52 --® and the associated 5014051 ensure reliability , GYP-SPAN logos are the reg

Isolation

Bare 1-1/4” (32 mm) FIRM-FILL® Brand Gypsum Concrete

3/8" 6" (10 mm) (152 mm) FIRM-FILL® concrete SCM-400 Sound Control Mat

None

Sheet NoneVinyl None

None

Bare

Rating -- IIC 50 7014063 STC 1652 -7014064 -- 50 5014051

---- 50 ∆ 23* 7014063 7014091 Sheet Vinyl -50 7014064 *Tested in accordance with ASTM E2179 – Standard Test Method for Laboratory Mea Bare -- Δ 23* 7014091 Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors. Bare

Bare

UL Fire Rated Designs Sound System 4: Hacker Sound Mat I, 3/4” (19 mm) FIRM-FILL® Brand Gypsum Concret

Steel Deck G230, G516, G524, G553, G561, G565, G566, G568, G587, G594, G595

® Subfloor M534 topping: 3/4” (19 mm) FIRM-FILL B Steel Joist L524, L527, L539, L543, L549, L551, L552, L564, M505, M511, M513, M515, Subfloor isolation: .08” (2 mm) Hacker Sound Concrete J917, J919, J920, J924, J927, J931, J957, J991, J994 Subfloor: 6” (152 mm) concrete

Contributes points to LEED® certification *Tested in accordance with ASTM E2179 - Standard Test Method for Laboratory Measurement of Effectiveness of Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors. FINISH STC IIC REPORT # Bare 54

53

--

5014076

Hacker | © 2017 BareIndustries, Inc. | Architect Binder | Firm-Fill® High -- Strength ∆ 15* 7014144


SUBMITTAL FORM Related Products FIRM-FILL® SCM sound control mats, Hacker Floor Primer, Hacker TopCoat™ SP and Hacker Floor Sealer are available for use with FIRM-FILL® High Strength. Contact Hacker Industries, Inc. at (800) 642-3455 or info@ hackerindustries.com for more info.

Warranty Subject to express warranty stated on Hacker Industries, Inc.’s website.

Submittal Approvals Project Name

Contractor/Architect

Signature

Date

PRODUCT INFORMATION See www.HackerIndustries.com for current recommended product specifications and literature. WARNING When mixed with water, this product hardens and becomes extremely hot. DO NOT attempt to make a cast enclosing any part of the body using this material. Failure to follow these instructions may cause severe burns that may require surgical removal of affected tissue or amputation of limb. Portland cement is strongly alkaline. Direct contact can be corrosive and cause severe damage or chemical burns to eyes and wet, moist skin. Avoid contact with eyes and skin. Wear protective glasses and clothing. If eye contact occurs, immediately flush thoroughly with water for 30 minutes and seek medical advice. Inhalation of dust may be corrosive or cause chemical burns or irritation to nose, throat and respiratory tract. Avoid breathing dust. Use a NIOSH/MSHA-approved dust respirator. Wash thoroughly with soap and water after use. Do not ingest. If ingested, call a physician. Product safety, call (800) 642-3455. KEEP OUT OF REACH OF CHILDREN.

TRADEMARKS FIRM-FILL®, GYP-SPAN®, Let Our Products Floor You™ and the associated logos are trademarks of Hacker Industries, Inc. LEED® is a registered trademark of the U.S. Green Building Council. WARRANTY HACKER INDUSTRIES, INC. SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, DIRECTLY OR INDIRECTLY SUSTAINED, NOR FOR ANY LOSS CAUSED BY APPLICATION OF THESE GOODS NOT IN ACCORDANCE WITH CURRENT PRINTED INSTRUCTION OR FOR OTHER THAN THE INTENDED USE. OUR LIABILITY IS EXPRESSLY LIMITED TO REPLACEMENT OF DEFECTIVE GOODS. ANY CLAIM SHALL BE DEEMED WAIVED UNLESS MADE IN WRITING TO US WITHIN 30 DAYS FROM DATE IT WAS, OR REASONABLY SHOULD HAVE BEEN, DISCOVERED. SAFETY FIRST Follow good safety/industrial hygiene practices during installation. Wear appropriate personal protective equipment. Read specs, MSDS and literature prior to specification and installation. © 2017 Hacker Industries, Inc., Newport Beach, CA.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® High Strength | © 2017

55


RECOMMENDED SPECIFICATIONS PART I: GENERAL 1.1

Scope

Specify to meet project requirements. The conditions of the Contract (General, Supplementary, and other conditions) and the General Requirements (sections of Division 1) govern the provisions of this section. 1.2

Qualifications

A.

Supplier: Hacker Industries, Inc., Newport Beach, California

B.

Installer: Installation of FIRM-FILL® High Strength shall be by a trained Licensed Applicator of Hacker Industries, Inc., using mixing and pumping equipment with a water meter approved by Hacker Industries, Inc.

C.

All materials specified herein shall be approved by Hacker Industries, Inc., Newport Beach, CA. All others must receive prior approval.

D.

Compressive strength shall be specified from 2500 to 3800 psi (17.2 to 26.2 MPa).

E.

Materials shall be delivered in their original, unopened packages, and protected from exposure to the elements before and after delivery. Do not allow bags to get wet. Product shall not be used beyond shelf life.

F.

Certification: Upon completion of this portion of the work, and as a condition of its acceptance, deliver to the architect a certificate from Hacker Industries, Inc., signed by the Licensed Applicator, stating that the material used in this work complies with the specified requirements.

PART II: PRODUCTS 2.1

Materials

A.

Gypsum Concrete: FIRM-FILL® High Strength, as supplied by Hacker Industries, Inc.

B.

Subfloor Primer: Hacker Floor Primer or approved equal

C.

Sand: 1/8” (3 mm) or less washed plaster, masonry sand or silica sand meeting requirements of Hacker Industries, Inc. Sand Guidelines

D.

Water: Potable and free from impurities

E.

Sealer: Hacker TopCoat™ SP (if specified)

2.2

Mix Design: See section 3.3

PART III: PREPARATION 3.1

Condition of Subfloor

A.

Subfloor shall be structurally sound, broom cleaned, dry and free from oil, grease, paraffin, laitance or other contaminants before the arrival of Hacker Licensed Applicator. The concrete substrate shall be 28 days or older and must be tested for moisture in accordance with ASTM F710.

B.

Before installation, the General Ccontractor (GC) shall inspect and approve the condition of the subfloor and test the existing subfloor for moisture.

56

Hacker Industries, Inc. | Architect Binder | Firm-Fill® High Strength | © 2017


RECOMMENDED SPECIFICATIONS (CONT.)

3.2

Preparation of Subfloor

A.

Leak Prevention: All cracks and voids shall be filled with a quick-setting patching or taping compound, or equal, where leakage may occur.

B.

Prime concrete subfloors using Hacker Floor Primer based upon job conditions.

C.

Hacker Floor Primer is not always required over concrete substrates. Multiple coats may be required over porous concrete or plank. The Hacker Licensed Applicator can give specific recommendations. (Note: For rehabilitation work or pours over old concrete, consult a Licensed Applicator or Hacker Industries, Inc. for recommended preparation.)

3.3

Mixing Instructions

A. Add 80-pound (36.3 kg) bag of FIRM-FILL® High Strength to 6 to 7 gallons (22.7 to 26.5 L) of water followed by the specific sand ratio. Do not overwater. Water amount will vary with the wetness of the sand.

This is the proper sequence for mixing of FIRM-FILL® High Strength.

First add water to bucket followed by FIRM-FILL® High Strength and finally the sand.

3.4

Underlayment Application

A.

Scheduling: 1. Installation of FIRM-FILL® High Strength shall not begin until the building is enclosed, including roof, windows, doors and other openings.

2. FIRM-FILL® High Strength may be installed before or after the installation of drywall, as specified.

B.

Application: 1. The minimum thickness of FIRM-FILL® High Strength varies with the type of concrete subfloor. FIRM-FILL® High Strength can be featheredged in low traffic areas over all concrete subfloors. The maximum thickness of FIRM-FILL® High Strength may be 3-1/2” (89 mm) in one lift.

2. Install FIRM-FILL® High Strength at specified thickness by placing contents of bags, sand and water into the approved high-speed mixing device with a water meter and blending for a minimum of one minute. FIRM-FILL® High Strength shall be pumped onto floor areas, spreading and screeding to a smooth surface. Place as continuously as possible until installation is complete so that no FIRMFILL® High Strength slurry is placed against FIRMFILL® High Strength that has obtained its initial set, except at authorized joints. 3. FIRM-FILL® High Strength is suitable for interior applications only and shall be covered by a finished floor covering.

C.

Protection: After installation, temporary wood planking shall be placed by the GC wherever the floor underlayment will be subject to wheeled and/or concentrated loads. The GC shall not place concentrated loads—such as pallets of material, drywall, taping compounds or any heavy items which may cause deflection—in the middle of the floor or in hallways.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® High Strength | © 2017

57


RECOMMENDED SPECIFICATIONS (CONT.)

Drying: Before, during and after installation of FIRM-FILL® High Strength, building interior shall be ventilated and heated to a minimum of 50°F (10°C) to ensure completion of the drying process. The GC must supply adequate ventilation and heat until the FIRM-FILL® High Strength is dry. If necessary, the GC shall provide mechanical ventilation. Do not install finished floor coverings until the FIRM-FILL® High Strength is tested for dryness. Consult flooring contractor for recommended procedures to test for dryness and acceptable levels of moisture. To avoid potential problems during the drying process, the GC shall consult Hacker Industries, Inc.’s Drying Conditions Flyer and information contained on Hacker Industries, Inc.’s website for additional information concerning drying of this product.

D.

3.5

Preparation for Installation of Floor Coverings

A.

Sealing: Any areas where the underlayment surface has been damaged shall be cleaned and sealed regardless of floor covering specified. Floor covering manufacturers’ specifications and requirements supersede these recommendations.

B.

Floor Covering Procedures: Please see Hacker Industries, Inc.’s Guidelines for Installing Finished Floor Coverings. The document is not a warranty and shall be used as a guideline only. See also ASTM F2419 for recommended procedures.

3.6

Field Quality Control

A.

Slump Test: FIRM-FILL® High Strength shall be tested for slump at the beginning of each installation in order to establish the required slump. Slump tests shall then be taken periodically during installation to verify that the required slump is maintained. Slump tests shall be conducted using a 2” by 4” (51 mm by 102 mm) cylinder. The acceptable patty size shall be 7-1/2” (191 mm) plus or minus 1/2” (13 mm) in diameter.

B.

Field Samples: Testing shall be done in accordance with ASTM C472 modified testing procedures using split brass molds. Prior to independent testing, consult Hacker Industries, Inc. for proper ASTM procedures.

Warranty: Subject to express warranty stated on Hacker Industries, Inc.’s website.

58

Hacker Industries, Inc. | Architect Binder | Firm-Fill® High Strength | © 2017


PROJECT REFERENCES Whether it’s leveling a small office or resurfacing an entire building, FIRM-FILL® High Strength is the costeffective solution for correcting damaged, uneven or cracked concrete in commercial projects. From featheredge in transition areas to 3-1/2”, FIRM-FILL® High Strength provides exceptional surface hardness with compressive strengths up to 3800 psi. Below is a small sample of the projects that have utilized FIRM-FILL® High Strength. Contractor: AA Boos & Sons Project: Fifth Third Field, Home of the Toledo Mudhens Location: Toledo, Ohio Description: 35,000 ft² of FIRM-FILL® High Strength Contractor: Austin Commercial Project: Southern Methodist University, Meadows Museum Location: Dallas, Texas Description: 10,000 ft² of FIRM-FILL® High Strength Contractor: Carlstrom Project: Bethany Assisted Living Location: Minong, Wisconsin Description: 6,992 ft² of FIRM-FILL® High Strength Contractor: Henderson Corporation Project: Administration Building Location: Somerville, New Jersey Description: 50,000 ft² of FIRM-FILL® High Strength Contractor: Morcon Project: Grand Hotel Location: Minneapolis, Minnesota Description: 19,069 ft² of FIRM-FILL® High Strength Contractor: Ninteman (The Sundt Companies, Inc.) Project: Scripps Hospital Location: La Jolla, California Description: 73,510 ft² of FIRM-FILL® High Strength Contractor: Peck Jones Construction Company Project: Reagan Presidential Library Location: Simi Valley, California Description: 16,000 ft² of FIRM-FILL® High Strength Contractor: Ryan Companies US, INC. Project: Grand Living Apts. Location: Sioux Falls, South Dakota Description: 195,000 ft² of FIRM-FILL® High Strength Contractor: Taegu Subway Construction Project: Unified Command Headquarters of Taegu Subway Location: City of Taegu, South Korea Description: 85,350 m² of FIRM-FILL® High Strength

Hacker Industries, Inc. | Architect Binder | Firm-Fill® High Strength | © 2017

59


Firm-Fill 4010 GYPSUM CONCRETE GYPSE DE BÉTON

FIRM-FILL® 4010+, a pourable floor underlayment from Hacker Industries, Inc. is designed for thin-capping concrete in new construction and renovation projects with no shot-blasting required. Installed from featheredge to 2”, fast-drying FIRM-FILL® 4010+ is poured over existing concrete or damaged, cracked concrete to provide a strong, flat surface for finished floor coverings. • Meets and exceeds ASTM F2419 and ASTM F710 • TCNA Methods; Over 100 UL Fire Rated Design Listings • ICC-ES Legacy Report • Fast drying underlayment; superior bonding characteristics • Compressive strengths up to 5200 psi; no shrinkage cracks • Smooth, rock-solid surface for finished floor coverings • Rapid installation; up to 40,000 square feet per day • Installed by trained Licensed Applicators


1 - FLOOR COVERING / 2 - FIRM-FILL® 4010 GYPSUM CONCRETE UNDERLAYMENT / 3 - FIRM-FILL® SCM 6 - BATT INSULATION / 7 - PARALLEL CHORD TRUSS / 8 - TJI ® JOIST / 9 - RESILIENT CHANNEL / 10 - GYP

2

2

F

onc ret e

1200200 0p FIR M si -F I L Gypsu L® mC

si 200 p 0- 5 ® 400 IL L M -F FIR p 01s0i 0 600 4 ® LU ED C CR E

Provides compressive strengths from 4000 - 5200 psi (27.5 to 35.9 MPa)

Ultra-high-strength on for performance L/360 precast concrete or Not a wear Deflection must slabs concrete

psi 000 to 6 D® CLU up REE -S C

onc ret e

UE

to up

4000-5200 4000-5200

TR

F

si

thU E -S

Ideal for commercial, institutional and renovation projects

®

TR

si 200 p 0- 5 ® 400 IL L M -F 0 401

4000-5200

FIR

Ultra-highstrength for performance on precast concrete or concrete slabs

1200200 0p FIR M si -F I L Gypsu L® mC

D M

D M

si

th

-F I L Gypsu L® mC onc ret e

psi psi 200 200 0-3 0-3 0 t 0 t n 0 a 0 i ® Radian 2 ® Rad 2 mi mi 4000-5200 psi Firm-Fill Firm-Fill® 4010+ n. AN n 1200-2000 A N® Gypsum Concrete P P FIR S F I R psi. 35 35 S P P 0 M 0 Y M Y ® ® 0 min. 3500 psi 0 Firm-Fill CMD GFirm-Fill 2010+00G0-3300 ps -F 2000-3200 -sFi p p 2000-3300 ppsi i IL 2 IL L ® si L ® si 2 ® 2000-3200 psi Firm-Fill 3310+ Gyp-Span Radiant ® 3000-3900 psi ® i F 50 C F I R 2M5-0 I L L si C F I R M -pFsI L L 0- 3 0- 3 0 0p ® ® 0 ® 1 0 0 3 3 F 1 8 0 3 FIR up to 6000 psi 80psi True-Screed CLU 2500-3800 IR 00 323 L L L High Strength 32Firm-Fill 0 I 0IL 0Hig M -F p Hig M -F p 00 M - F + hS 00 M - F + h I I 0 LL St 0 tre L L re I R 201 I R 201 ng ng ®

© 2017 Hacker Industries, Inc. FIRM-FILL® and the associated logos are trademarks of Hacker Industries, Inc., Newport Beach, CA.

F

2

0 psi -320 0 0 t ® Radian 20 PAN S P GY 2000-3300 ® ® M CONCRETE1UNDERLAYMENT /23- FIRM-FILL - FIRM-FILL SCM OR HACKER MATOR / 4 -OSB PLYWOOD OR OSB /HACKER 5 - NOMINAL WOOD / ® 4010+ NDERLAYMENT 3 - FIRM-FILL OR HACKER SOUND MAT / 4 -SOUND PLYWOOD 5 - NOMINAL WOOD JOIST / MAT ® 4010+ ® SCM -/FLOOR COVERING /SCM GYPSUM CONCRETE UNDERLAYMENT / 3 - /FIRM-FILL OR SOUND / 4 - JOIST FIRM-FILL i F I R M -F I L ps GYPSUM CONCRETE DAMAGED 5 - 6” CONCRETE S/ 9 / 8- -RESILIENT TJI ® JOIST / 9 - RESILIENT CHANNELWALLBOARD / 10 OVER - GYPSUM // 11 - 6” CONCRETE CHANNEL / 10 - UNDERLAYMENT GYPSUM / 11WALLBOARD - 6”CONCRETE CONCRETE 00 ® 3310 2 -3 LL I 0 00 M - F + 0 I R 201 6000 psi 0 psi 1000 psi 2000 psi 3000 psi 4000 psi 5000 psi

UL fire rated designs for 1-4 hour fire ratings

4000-5200 Contributes points to LEED® project certification

Installed by Hacker Industries’ trained Licensed Applicators

Ideal for commercial, Provides compresinstitutional and sive strengths from renovation projects 4000 - 5200 psi Subfloor must One component(27.5 Wearto appropriate 35.9 MPa)

Requires dryin (building surface; requires not exceed L/360 be protected by of an effective must be fully finished floor live or dead load vapor barrier if sound & fire enclosed before covering installed above control system mmercial, UL designs for 1-4 Contributes points compresProvides UL designs for 1-4 Contributes points Installed Provides compresinstallation) crawl space ®

personal protective equipment Installed by only only

by from and strengths hour fire ratings to LEED project strengths Hacker Industries’ sivefrom hour fire ratings to LEED® project Hacker Industries’ sive certification Licensed Applicators projects - 5200 psi Licensed Applicators 4000 certification 4000 - 5200 Hackerpsi Industries, Inc. | Architect Binder | Firm-Fill® 4010+ | © 2017 61 to 35.9 MPa) (27.5 MPa) (27.5 to 35.9

U h


SUBMITTAL FORM TECHNICAL DATA

PROPERTIES

ASTM

Weight

5.3 lb/ft² (25.8 kg/m²) at 1/2” (13 mm)

C472 M

Thickness

Featheredge at transitions to 1-1/2” (38 mm)

F2419

Compressive Strength

4000 to 5200 psi (27.5 to 35.9 MPa)

C472 M

Thermal Performance

K-value of 2.8 BTU/(hr.ft.F°); R-value of 0.36 (ft².hr.F°)

C177

Fire Hazard Classification

Flamespread index 0: Fuel contribution 0; Smoke density 0

E84

Sand

1/8” (3 mm) or less washed plaster or masonry sand

C33

Flexural Strength

1300 psi (8.96 MPa)

C348

Benefits • • • • • • • • •

Ultra-high-strength underlayment for use over concrete slabs or precast concrete Listed in over 100 UL fire rated floor/ceiling assemblies Lightweight and crack-resistant Ideal for commercial, institutional and renovation projects UL fire rated designs for 1-4 hour fire ratings No shot blasting or surface preparation required Helps contribute points to LEED® project certification Creates a flat, durable underlayment surface for finished floor coverings Installed only by trained Licensed Applicators across North America

Product Description FIRM-FILL® 4010+ is a gypsum floor underlayment from Hacker Industries, Inc. that is designed for thincapping concrete in new construction or renovation projects with no shot blasting required. FIRM-FILL® 4010+ sets in 90 minutes and is suitable for light foot traffic the following day. Installed from featheredge to 2”, FIRMFILL® 4010+ is widely used over existing concrete, precast, and damaged or cracked lightweight concrete to create a strong, flat surface for finished floor coverings. FIRM-FILL® 4010+ provides compressive strengths from 4000 to 5200 psi (27.5 to 35.9 MPa). FIRM-FILL® 4010+ is mixed on the job site with local washed plaster, masonry or silica sand (per ASTM C33) and water to create a lightweight slurry. At 1/2” thick, the underlayment weighs approximately 5.3 lb/ft² (25.8 kg/m²) with a dry density range of 125-130 pcf. For new construction or renovation, FIRM-FILL® 4010+ is a cost-efficient way to maximize sound control and provide fire ratings, and is suitable for a variety of finished floor coverings.

Limitations • Do not use FIRM-FILL® 4010+ in exterior locations, below grade or where continuous exposure to moisture is likely. • Shall not be used as a wear surface; must be covered by a finished floor covering. • Structure shall be designed so that deflection does not exceed L/360 live or dead load. Certain floor coverings, such as marble, limestone, travertine and wood, may have more restrictive deflection limits. Consult the appropriate floor covering manufacturer for recommendations. • If installed above a crawl space, subfloor must be protected by a vapor barrier. • No single application of FIRM-FILL® 4010+ shall exceed 1-1/2” in depth. • FIRM-FILL® 4010+ is one component of an effective sound and fire control system. Care must be taken in the installation of all components to assure the ultimate design performance. Published acoustical and fire system tests were conducted under controlled laboratory or field conditions and reflect results applicable only to those specific assemblies. 62

Hacker Industries, Inc. | Architect Binder | Firm-Fill® 4010+ | © 2017


Firm-Fill 4010

SUBMITTAL FORM

GYPSUM CONCRETE GYPSE DE BÉTON

Installation Before, during and after the installation of FIRM-FILL® 4010+, the building must be enclosed and the temperature maintained at a minimum of 50°F (10°C). Prior to the installation of FIRM-FILL® 4010+, the subfloor shall be structurally sound (L/720), broom cleaned, dry and free from oil, grease, paraffin, laitance, wax or other contaminants. Adequate ventilation shall be provided by the General Contractor (GC) to ensure proper drying of FIRMFILL® 4010+. If necessary, the GC shall provide mechanical ventilation. Depending on thickness and drying conditions, the underlayment should dry within 7 to 12 days. To avoid potential problems during the drying process, the GC shall consult Hacker Industries, Inc.’s Drying Conditions Flyer and information contained on Hacker Industries, Inc.’s website for additional information concerning drying of this product. Cracks in the existing concrete subfloor must be inspected to determine if the crack is due to typical concrete shrinkage, or if it is a result of a structural movement. In the case of the latter, remediation of the crack must be addressed lest the crack eventually telegraph through Hacker Industries, Inc. FIRM-FILL® 4010+. Repair all existing cracks in concrete substrate to minimize and control their ability to telegraph through the layer of Hacker Industries, Inc. FIRM-FILL® 4010+. Remove all weakened concrete along the length of the cracks by chiseling or other suitable means. Remove accumulated dust and debris from the crack cavities using a vacuum, or other suitable means. Various cracks present in the concrete subfloor, including shrinkage cracks, must be filled with a suitable commercially available crack-fill epoxy adhesive designed for concrete flooring applications. To ensure superior resistance to crack growth, use injection epoxy crack-repair techniques per industry guidelines to repair cracks that are active or deep. Note that repair of existing cracks in the concrete subfloor only subdues, but does not completely prevent their ability to telegraph through Hacker Industries, Inc. FIRM-FILL® 4010+ floor underlayment. Growth of existing cracks or formation of new cracks in the concrete subfloor may lead to cracks telegraphing through Hacker Industries, Inc. FIRM-FILL® 4010+ floor underlayment. Respect existing expansion and control joints. Concrete subfloors receiving a Hacker Industries, Inc. FIRM-FILL® 4010+ underlayment must be cured properly (generally for a minimum of 28 days) prior to the underlayment installation. For on- or above- grade applications on concrete subfloors or concrete planks, measure the Moisture Vapor Emission Rate (MVER) using ASTM F1869. MVER should be below 3 lbs./1000 ft.2/24 hrs. Concrete subfloors should be treated properly with Hacker Industries, Inc. Concrete Primer according to its written recommendations, “Guidelines for Finished Floor Coverings for floor-covering installation.“ After installation, temporary wood planking shall be placed by the GC wherever the floor underlayment will be subject to wheeled or concentrated loads.

Product Data Approximate Compressive Strength per ASTM C472 Modified: Approximate Dry Density (aggregated):

4000 to 5200 psi* (27.5 to 35.9 MPa) 125 to 130 pcf

*Note: Compressive strengths published herein were achieved under controlled laboratory conditions. Actual field results may differ due to environmental conditions, regional sand variations, or inconsistent proportioning of field-applied water, sand and Hacker Floor Underlayment, as well as differences in mixing/pumping equipment.

Compliance • ICC-ES ER-4147 • City of Los Angeles Research Report No. 24540

• FHA-HUD MR 1255 • Tile Council of North America (F180, F200, RH111, RH122)

Hacker Industries, Inc. | Architect Binder | Firm-Fill® 4010+ | © 2017

63


Hacker Industries, Inc.

SUBMITTAL FORM

Acoustic

6” (152 mm) CONCRETE ASSEMBLY

Sound System 3: FIRM-FILL® SCM-400, 1-1/4” (32 mm) FIRM-FILL® Brand Gypsum Concre

Subfloor topping: 1-1/4” (32 mm) FIRM-FILL® B Subfloor isolation: 3/8” (10 mm) FIRM-FILL® SC Subfloor: 6” (152 mm) concrete

Sound Test & UL Fire Rated Designs

PURPOSE STATEMENT/DISCLAIMER These guidelines are designed to provide the architectural and building communities with detailed performance data on Hacker Industries, Inc.’s comprehensive portfolio of sound attenuation tests and UL Fire Rated Designs. The tests for the assemblies included in these guidelines were conducted in a laboratory FINISH STC IIC REPORT # setting per ASTM C177, E84, E90, E492 and E2179. These guidelines are not warranties and should be used as guidelines only. The architects’ and general contractors’ recommendations supersede these Field Bare 52guidelines. -5014051 performance may vary. Subject to express Warranty stated on Hacker Industries, Inc.’s website. Bare

--

50

7014063

Hacker Industries, Inc. regularly performs acoustical standards Sheet Vinyl and fire (UL) testing to ensure performance -50 7014064 for our products. Firm-Fill® gypsum concretes, including Firm-Fill® 4010+, were tested acoustically with the -∆ 23* 7014091 following floor assemblies and performedBare as noted.

*Tested in accordance with ASTM E2179 – Standard Test Method for Laboratory Measu Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors.

Sound System 4: Hacker Sound Mat I, 3/4” (19 mm) FIRM-FILL® Brand Gypsum Concrete

Subfloor topping: 3/4” (19 mm) FIRM-FILL® Bra Subfloor isolation: .08” (2 mm) Hacker Sound M Subfloor: 6” (152 mm) concrete Contributes points to LEED® certification

FINISH Firm-FIll 4010+ – Concrete Assembly 1 Subfloor Topping 3/4” (19 mm) FIRM-FILL® Brand Gypsum Concrete

Sound Mat .08" (2 mm) Hacker Sound Mat I

Subfloor Insulation Bare Truss Bare 6" (152 mm) concrete

None

Ceiling Isolation

Ceiling

STC Finish

IIC

REPORT #

# 53Sound-- Report 5014076 Rating -∆ 15* 7014144 STC IIC

None None None Bare 53 -5014076 *Tested in accordance with ASTM E2179 – Standard Test Method for Laboratory Measu Bare Transmission -- Δ15* 7014144 Floor Coverings in Reducing Impact Sound Through Concrete Floors.

Contributes points to LEED® certification. UL Fire Rated Designs Steel Deck G230, G516, G524, G553, G561, G565, G566, G568, G587, G594, G595 Steel Joist L524, L527, L539, L543, L549, L551, L552, L564, M505, M511, M513, M515, M534 Concrete J917, J919, J920, J924, J927, J931, J957, J991, J994

These guidelines shall only be a resource and are not a guarantee of performance. FIRM-FILL® SCM Underlayments are only one componen acoustical performance is affected by every other component. The likelihood of achieving code compliance is contingent upon many other tra plumbers and drywall contractors. Developers and general contractors are responsible for building properly and testing field performance as soon of the project. Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or constru a professional acoustical consultant to assure specifications are written correctly and that the floor/ceiling assembly can perform to expectations. ensure reliability of design prior to occupancy. © 2/2016 Hacker Industries, Inc. FIRM-FILL®, GYP-SPAN® and the associated logos are the regi

*Tested in accordance with ASTM E2179 - Standard Test Method for Laboratory Measurement of Effectiveness of Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors.

17 64

Hacker Industries, Inc. | Architect Binder | Firm-Fill® 4010+ | © 2017


6” (152 mm) CONCRETE ASSEMBLY

Sound System 1: FIRM-FILL® SCM-125, 3/4” (19 mm) FIRM-FILL® Brand Gypsum Concret

Firm-Fill

SUBMITTAL FORM

3/4” (19 mm) FIRM-FILL® Brand Gypsum Concrete

GYPSE DE BÉTON

Hacker Industries, Inc.Hacker Industries, Inc.

Acoustic

FINISH STC IIC REPORT # Firm-FIll 4010+ – Concrete Assembly 2 51 5014050 Sound Subfloor InsulationBareTruss Ceiling Ceiling Finish Sound -- Report # Mat Isolation Rating ® ® Sound Brand7014090 Gypsum Concrete Bare System 1: FIRM-FILL SCM-125, 3/4” (19 mm) --FIRM-FILL ∆ 20* STC IIC Subfloor topping: mm) FIRM-FILL® Br 1/8" 6" None None None None Bare 51 3/4” -- (19 5014050 Subfloor isolation: 1/8” (3 mm) FIRM-FILL® SCM (3 mm) (152 mm) Bare -- mm) Δ ® Brand 7014090 ® ® Sound System 2: FIRM-FILL SCM-250, 1” (25 mm) Gypsum Concrete Subfloor: 6”FIRM-FILL (152 concrete FIRM-FILL concrete 20* SCM-125 Sound Subfloor topping: 1” (25) mm FIRM-FILL® Bra Control Subfloor isolation: 1/4” (6 mm) FIRM-FILL® SC Mat Subfloor: 6” (152 mm) concrete 6” (152 mm) CONCRETE ASSEMBLY

Subfloor Topping

Subfloor topping: 3/4” (19 mm) FIRM-FILL® B Subfloor isolation: 1/8” (34010 mm) FIRM-FILL® SC GYPSUM CONCRETE Subfloor: 6” (152 mm) concrete

UL Fire Rated Designs FINISH Steel Deck G230, G516, G524, G553, BareG561, G565, G566, G568, G587, G594, G595

STC

51 Steel Joist L524, L527, L539, L543, L549, L551, L552, L564, M505, M511, M513, M515, M534 Bare -FINISHJ931, J957, J991, J994 STC Concrete J917, J919, J920, J924, J927, Bare

IIC

REPORT #

--

5014050

∆ 20* IIC

7014090 REPORT #

51

--

5014075

Sound Concrete Bare System 2: FIRM-FILL SCM-250, 1” (25 mm) FIRM-FILL -∆Brand 20* Gypsum 7014143 ®

®

Subfloor topping: 1” (25) mm FIRM-FILL® Bran Subfloor isolation: 1/4” (6 mm) FIRM-FILL® SCM Subfloor: 6” (152 mm) concrete

FINISH Firm-FIll 4010+ – Concrete Assembly 3 Subfloor Topping 1” (25 mm) FIRM-FILL® Brand Gypsum Concrete

Sound Mat

Subfloor

1/4" 6" (6 mm) (152 mm) FIRM-FILL® concrete SCM-250 Sound Control Mat

Insulation Bare Truss Bare None

None

Ceiling Isolation None

Ceiling

None

STC Finish

IIC

REPORT #

# 51Sound-- Report 5014075 Rating -∆ 20* 7014143 STC IIC

Bare

51

--

5014075

Bare

--

Δ 20*

7014143

UL Fire Rated Designs

Steel Deck G230, G516, G524, These G553, G561,shall G565, G566, G568, G587, G594, G595 guidelines only be a resource and are not a guarantee of performance. FIRM-FILL® SCM Underlayments are only one compon

acoustical performance is affected by every other component. The likelihood of achieving code compliance is contingent upon many other

Steel Joist L524, L527, L539, L543, L549, L551, L552, L564, M505, M511, M513, M515, M534 plumbers and drywall contractors. Developers and general contractors are responsible for building properly and testing field performance as so

of the project. Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or cons Concrete J917, J919, J920, J924, J927, acoustical J931, J957, J991, J994specifications are written correctly and that the floor/ceiling assembly can perform to expectation a professional consultant to assure

ensure reliability of design prior to occupancy. © 2/2016 Hacker Industries, Inc. FIRM-FILL®, GYP-SPAN® and the associated logos are the re

16 *Tested in accordance with ASTM E2179 - Standard Test Method for Laboratory Measurement of Effectiveness of Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® 4010+ | © 2017

65

These guidelines shall only be a resource and are not a guarantee of performance. FIRM-FILL SCM Underlayments are only one compone ®


Subfloor Topping 1-1/4” (32 mm) FIRM-FILL® Brand Gypsum Concrete

Sound Mat

6” (152 mm) CONCRETE ASSEMBLY

SUBMITTAL FORM

Sound System 3: FIRM-FILL® SCM-400, 1-1/4” (32 mm) FIRM-FILL® Brand Gypsum Conc

Subfloor topping: 1-1/4” (32 mm) FIRM-FILL Subfloor isolation: 3/8” (10 mm) FIRM-FILL® Subfloor: 6” (152 mm) concrete

FINISH Firm-FIll 4010+ – Concrete Assembly 4 Subfloor Insulation Bare Truss Ceiling Ceiling Isolation Bare

3/8" 6" (10 mm) (152 mm) FIRM-FILL® concrete SCM-400 Sound Control Mat

None

Sheet Vinyl None None Bare

None

STC Finish

Bare Bare

IIC

REPORT #

52 5014051 Sound -- Report # Rating -50 7014063 STC IIC -50 7014064 52 -5014051 7014091 ---50 ∆ 23* 7014063

Sheet –Vinyl -- Test50Method 7014064 *Tested in accordance with ASTM E2179 Standard for Laboratory Mea -- Δ 23* 7014091 Floor Coverings in Reducing ImpactBare Sound Transmission Through Concrete Floors.

Sound System 4: Hacker Sound Mat I, 3/4” (19 mm) FIRM-FILL® Brand Gypsum Concret UL Fire Rated Designs

Steel Deck G230, G516, G524, G553, G561, G565, G566, G568, G587, G594, G595 Subfloor topping: 3/4” (19 mm) FIRM-FILL® B Subfloor .08” (2 mm) Hacker Sound Steel Joist L524, L527, L539, L543, L549, L551, L552, L564, M505, M511, M513, M515, isolation: M534 Subfloor: 6” (152 mm) concrete Concrete J917, J919, J920, J924, J927, J931, J957, J991, J994 Contributes points to LEED® certification

FINISH

STC

IIC

REPORT #

Bare

53

--

5014076

Bare

--

∆ 15*

7014144

*Tested in accordance with ASTM E2179 – Standard Test Method for Laboratory Mea Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors.

These guidelines shall only be a resource and are not a guarantee of performance. FIRM-FILL® SCM Underlayments are only one compo acoustical performance is affected by every other component. The likelihood of achieving code compliance is contingent upon many othe plumbers and drywall contractors. Developers and general contractors are responsible for building properly and testing field performance as s of the project. Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or con a professional acoustical consultant to assure specifications are written correctly and that the floor/ceiling assembly can perform to expectati ensure reliability of design prior to occupancy. © 2/2016 Hacker Industries, Inc. FIRM-FILL®, GYP-SPAN® and the associated logos are the

17

*Tested in accordance with ASTM E2179 - Standard Test Method for Laboratory Measurement of Effectiveness of Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors.

66

Hacker Industries, Inc. | Architect Binder | Firm-Fill® 4010+ | © 2017


Firm-Fill 4010

SUBMITTAL FORM

GYPSUM CONCRETE GYPSE DE BÉTON

Related Products FIRM-FILL® SCM sound control mats, Hacker Floor Primer, Hacker TopCoat™ SP and Hacker Floor Sealer are available for use with FIRM-FILL® 4010+. Contact Hacker Industries, Inc. at (800) 642-3455 or info@ hackerindustries.com for more information.

Warranty Subject to express warranty stated on Hacker Industries, Inc.’s website.

Submittal Approvals Project Name

Contractor/Architect

Signature

Date

PRODUCT INFORMATION See www.HackerIndustries.com for current recommended product specifications and literature. WARNING When mixed with water, this product hardens and becomes extremely hot. DO NOT attempt to make a cast enclosing any part of the body using this material. Failure to follow these instructions may cause severe burns that may require surgical removal of affected tissue or amputation of limb. Portland cement is strongly alkaline. Direct contact can be corrosive and cause severe damage or chemical burns to eyes and wet, moist skin. Avoid contact with eyes and skin. Wear protective glasses and clothing. If eye contact occurs, immediately flush thoroughly with water for 30 minutes and seek medical advice. Inhalation of dust may be corrosive or cause chemical burns or irritation to nose, throat and respiratory tract. Avoid breathing dust. Use a NIOSH/MSHA-approved dust respirator. Wash thoroughly with soap and water after use. Do not ingest. If ingested, call a physician. Product safety, call (800) 642-3455. KEEP OUT OF REACH OF CHILDREN.

TRADEMARKS FIRM-FILL®, GYP-SPAN®, Let Our Products Floor You™ and the associated logos are trademarks of Hacker Industries, Inc. LEED® is a registered trademark of the U.S. Green Building Council. WARRANTY HACKER INDUSTRIES, INC. SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, DIRECTLY OR INDIRECTLY SUSTAINED, NOR FOR ANY LOSS CAUSED BY APPLICATION OF THESE GOODS NOT IN ACCORDANCE WITH CURRENT PRINTED INSTRUCTION OR FOR OTHER THAN THE INTENDED USE. OUR LIABILITY IS EXPRESSLY LIMITED TO REPLACEMENT OF DEFECTIVE GOODS. ANY CLAIM SHALL BE DEEMED WAIVED UNLESS MADE IN WRITING TO US WITHIN 30 DAYS FROM DATE IT WAS, OR REASONABLY SHOULD HAVE BEEN, DISCOVERED. SAFETY FIRST Follow good safety/industrial hygiene practices during installation. Wear appropriate personal protective equipment. Read specs, MSDS and literature prior to specification and installation. © 2017 Hacker Industries, Inc., Newport Beach, CA.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® 4010+ | © 2017

67


RECOMMENDED SPECIFICATIONS PART I: GENERAL 1.1

Scope

Specify to meet project requirements. The conditions of the Contract (General, Supplementary, and other conditions) and the General Requirements (sections of Division 1) govern the provisions of this section. 1.2

Qualifications

A.

Supplier: Hacker Industries, Inc., Newport Beach, California

B.

Installer: Installation of FIRM-FILL® 4010+ shall be by a trained Licensed Applicator of Hacker Industries, Inc., using mixing and pumping equipment with a water meter approved by Hacker Industries, Inc.

C.

All materials specified herein shall be approved by Hacker Industries, Inc., Newport Beach, CA. All others must receive prior approval.

D.

Compressive strength shall be specified from 4000 to 5200 psi (27.6 to 35.9 MPa).

E.

Materials shall be delivered in their original, unopened packages, and protected from exposure to the elements before and after delivery. Do not allow bags to get wet. Product shall not be used beyond shelf life.

F.

Certification: Upon completion of this portion of the work, and as a condition of its acceptance, deliver to the architect a certificate from Hacker Industries, Inc., signed by the Licensed Applicator, stating that the material used in this work complies with the specified requirements.

PART II: PRODUCTS 2.1

Materials

A.

Gypsum Concrete: FIRM-FILL® 4010+, as supplied by Hacker Industries, Inc.

B.

Subfloor Primer: Hacker Floor Primer or approved equal

C.

Sand: 1/8” (3 mm) or less washed plaster, masonry sand or silica sand meeting requirements of Hacker Industries, Inc. Sand Guidelines

D.

Water: Potable and free from impurities

E.

Sealer: Hacker TopCoat™ SP (if specified)

2.2

Mix Design: See section 3.3

PART III: PREPARATION 3.1

Condition of Subfloor

A.

68

Subfloor shall be structurally sound, broom cleaned, dry and free from oil, grease, paraffin, laitance, wax or other contaminants before the arrival of Hacker Licensed Applicator. The concrete substrate shall be 28 days or older and must be tested for moisture in accordance with ASTM F710.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® 4010+ | © 2017


RECOMMENDED SPECIFICATIONS (CONT.)

Firm-Fill 4010 GYPSUM CONCRETE GYPSE DE BÉTON

Before installation, the General Contractor (GC) shall inspect and approve the condition of the subfloor and test the existing subfloor for moisture.

B.

3.2

Preparation of Subfloor

A.

Leak Prevention: All cracks and voids shall be filled with a quick-setting patching or taping compound, or equal, where leakage may occur.

B.

Prime concrete subfloors using Hacker Floor Primer based upon job conditions.

C.

Hacker Floor Primer is not always required over concrete substrates. Multiple coats may be required over porous concrete or plank. The Hacker Licensed Applicator can give specific recommendations. (Note: For rehabilitation work or pours over old concrete, consult a Licensed Applicator or Hacker Industries, Inc. for recommended preparation.)

3.3

Mixing Instructions

A.

Add 80-pound (36.3 kg) bag of FIRM-FILL® 4010+ to 6 to 7 gallons (22.7 to 26.5 L) of water followed by the specific sand ratio. Do not overwater. Water amount will vary with the wetness of the sand.

This is the proper sequence for mixing of FIRM-FILL® 4010+.

First add water to bucket followed by FIRM-FILL® 4010+ and finally the sand.

3.4

Underlayment Application

A.

Scheduling: 1. Installation of FIRM-FILL® 4010+ shall not begin until the building is enclosed, including roof, windows, doors and other openings.

2. FIRM-FILL® 4010+ may be installed before or after the installation of drywall, as specified.

B.

Application:

1. The minimum thickness of FIRM-FILL® 4010+ varies with the type of concrete subfloor. FIRM-FILL® 4010+ can be featheredged in transition areas over all concrete subfloors. The maximum thickness of FIRM-FILL® 4010+ may be 2” (51 mm) in one lift.

2. Install FIRM-FILL® 4010+ at specified thickness by placing contents of bags, sand and water into the approved high-speed mixing device and blending for a minimum of one minute. FIRM-FILL® 4010+ shall be pumped onto floor areas, spreading and screeding to a smooth surface. Place as continuously as possible until installation is complete so that no FIRM-FILL® 4010+ slurry is placed against FIRM-FILL® 4010+ that has obtained its initial set, except at authorized joints.

3. FIRM-FILL® 4010+ is suitable for interior applications only and must be covered by a finished floor covering.

C.

Protection: After installation, temporary wood planking shall be placed by the GC wherever the floor underlayment will be subject to wheeled or concentrated loads. The GC shall not place concentrated loads—such as pallets of material, drywall, taping compounds or any heavy material which may cause deflection—in the middle of the floor or in hallways.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® 4010+ | © 2017

69


RECOMMENDED SPECIFICATIONS (CONT.)

Drying: Before, during and after installation of FIRM-FILL® 4010+, building interior shall be ventilated and heated to a minimum 50°F (10°) to ensure completion of the drying process. The GC must supply mechanical ventilation and heat if necessary. Do not install finished floor coverings until the FIRM-FILL® 4010+ is tested for dryness. Consult flooring contractor for recommended procedures to test for dryness and acceptable levels of moisture. To avoid potential problems during the drying process, the GC shall consult Hacker Industries, Inc.’s Drying Conditions Flyer and information contained on Hacker Industries, Inc.’s website for additional information concerning drying of this product.

D.

3.5

Preparation for Installation of Floor Coverings

A.

Sealing: Any areas where the underlayment surface has been damaged shall be cleaned and sealed regardless of floor covering specified. Floor covering manufacturers’ specifications and requirements supersede these recommendations.

B.

Floor Covering Procedures: Please see Hacker Industries, Inc.’s Guidelines for Installing Finished Floor Coverings. The document is not a warranty and shall be used as a guideline only. See ASTM F2419.

3.6

Field Quality Control

A.

Slump Test: FIRM-FILL® 4010+ shall be tested for slump at the beginning of each installation in order to establish the required slump. Slump tests shall then be taken periodically during installation to verify that the required slump is maintained. Slump tests shall be conducted using a 2” by 4” (51 mm by 102 mm) cylinder. The acceptable patty size shall be 8” (208 mm) plus or minus 1/2” (13 mm) in diameter.

B.

Field Samples: Testing shall be done in accordance with ASTM C472 modified testing procedure using split brass molds. Prior to independent testing, consult Hacker Industries, Inc. for proper ASTM procedures.

Warranty: Subject to express warranty stated on Hacker Industries, Inc.’s website.

70

Hacker Industries, Inc. | Architect Binder | Firm-Fill® 4010+ | © 2017


Firm-Fill 4010

PROJECT REFERENCES

GYPSUM CONCRETE GYPSE DE BÉTON

FIRM-FILL® 4010+ is a pourable floor underlayment from Hacker Industries, Inc. designed for thin-capping concrete in new construction or renovation projects with no-shot blasting required. Installed from featheredge to 2”, fast-drying FIRM-FILL® 4010+ poured over existing concrete, precast, or damaged or cracked lightweight concrete provides a strong, flat surface for finished floor coverings. Below is a small sample of projects that have utilized FIRM-FILL® 4010+. Contractor: AP Wisconsin Project: Onieda County Courthouse Location: Rhinelander, Wisconsin Description: 12,871 ft² of FIRM-FILL® 4010 Contractor: Beers Construction Project: Sumter Regional Hospital Location: Americus, Georgia Description: 7,754 ft² of FIRM-FILL® 4010 Contractor: Brindley Construction Group Project: VA Hospital, Pharmacy Renovation Location: Murfreesboro, Tennessee Description: 1,550 ft² of FIRM-FILL® 4010

Contractor: MKB Contractors Project: Scott Air Force Base, Hangar #1, Building 433 Location: Belleville, Illinois Description: 33,252 ft² of FIRM-FILL® 4010 Contractor: Prime Contractors, Inc. Project: Jefferson Street Jail Location: Atlanta, Georgia Description: 16,961 ft² of FIRM-FILL® 4010

Contractor: Camden Builders Inc Project: Camden Waterford Location: Orlando, FL Description: 374,735 ft² of FIRM-FILL® 4010 Contractor: Dave’s Construction Project: Belk at Cool Springs Location: Brentwood, Tennessee Description: 5,400 f² of FIRM-FILL® 4010 Contractor: Devcon Construction Project: Hampton Inn, Bodo Location: Boise, Idaho Description: 14,700 ft² of FIRM-FILL® 4010 Contractor: Hand Construction, Inc. Project: Timbers of Terrell, Building #1 Location: Terrell, Texas Description: 10,000 ft² of FIRM-FILL® 4010 Contractor: Healy Construction Project: Northfield Resource Center Location: Northfield, Minnesota Description: 10,000 ft² of FIRM-FILL® 4010 Contractor: Hoffman Corporation Project: Hoffman Corporation Home Office Location: Greenville, Wisconsin Description: 8,000 ft² of FIRM-FILL® 4010

Hacker Industries, Inc. | Architect Binder | Firm-Fill® 4010+ | © 2017

71


Build higher and faster with FIRM-FILL® CMD (corrugated steel deck) from Hacker Industries, Inc., the leader in pourable floor underlayments. Designed for use in multi-family, commercial and institutional buildings with light-gauge steel framing and a corrugated steel deck, FIRM-FILL® CMD is a lightweight, high-strength gypsum concrete floor underlayment. Installed at 1” above the top of the flutes (1-9/16” total), FIRM-FILL® CMD reduces dead loads, which can significantly lower costs. • The lightweight solution for fast-track construction • UL fire rated design floor/ceiling assembly G565, G568; 1, 1½ or 2 hour fire ratings • Applied directly over primed corrugated steel deck • Minimum compressive strength 3500 psi (24 MPa) • Installed by trained Licensed Applicators


1

1

2

2

12

13

13

6

12

9

6

9

10

10

1 - FLOOR COVERING / 2 - FIRM-FILL® CMD GYPSUM CONCRETE UNDERLAYMENT / 3 - FIRM-FILL® SCM OR HACKER SOUND MAT / 4 - FIRM-FILL® CMD GYPSUM CONCRETE UNDERLAYMENT TO FILL FULTES / 6 - BATT INSULATION / 9 - RESILIENT CHANNEL / 10 - GYPSUM WALLBOARD / 12 - 22 MSG GALVANIZED CORRUGATED STEEL DECK / 13 - 16 MSG GALVANIZED, CHANNEL-SHAPED, 9-1/4” (231MM) MIN. STEEL JOIST

0 psi

1000 psi

© 2016 Hacker Industries, Inc. FIRM-FILL® and the associated logos are trademarks of Hacker Industries, Inc., Newport Beach, CA.

Firm-Fill® Gypsum Concrete

2000 psi

3000 psi

4000 psi

5000 psi

1200-2000 psi

Firm-Fill® 4010+

Firm-Fill® 2010+

2000-3200 psi

Firm-Fill® CMD

Firm-Fill® 3310+

3000-3900 psi

Gyp-Span Radiant

2000-3200 psi

Firm-Fill® High Strength

2500-3800 psi

True-Screed CLU

up to 6000 psi

1” > FLUTES

6000 psi

4000-5200 psi min. 3500 psi

>3500

2” LIFT

Use in coldRequires 1” over formed steel top of flutes; max. construction with lift depth of 2” a corrugated steel deck

Provides compressive strengths over 3500 psi (24.1 MPa)

Install with Hacker Sound Mat or FIRMFILL® SCM for additional isolation

Contributes points to LEED® project certification

Installed by Hacker Industries’ trained Licensed Applicators

Subfloor must be protected by vapor barrier if installed above crawl space

One component of an effective sound & fire control system

Wear appropriate personal protective equipment

L/360

Requires dryin (building must be fully enclosed before installation)

Not a wear surface; requires finished floor covering

Deflection must not exceed L/360 live or dead load

Hacker Industries, Inc. | Architect Binder | Firm-Fill® CMD | © 2017

73


SUBMITTAL FORM TECHNICAL DATA Weight Thickness Compressive Strength Fire Hazard Classification Sand

PROPERTIES Minimum 12.8 lb/ft² (62.47 kg/m²) at 1-9/16” (40 mm) 1” (25 mm) above the top of the flutes Minimum 3500 psi (24.1 MPa) Flamespread index 0: Fuel contribution 0; Smoke density 0 1/8” (3 mm) or less washed plaster or masonry sand

ASTM C472 M C472 M E84 C33

Benefits • • • • • • •

For use in cold-formed steel frame construction with a corrugated steel deck Install over a FIRM-FILL® SCM or Hacker Sound Mat for additional sound isolation Lightweight solution for fast-track construction Rapid set time; can be walked on in 2 hours Helps contribute points to LEED® project certification Creates a flat, durable surface for finished floor coverings Installed only by trained Licensed Applicators across North America

Product Description FIRM-FILL® CMD is designed for use in cold-formed steel frame buildings with a corrugated steel deck. FIRMFILL® CMD provides minimum compressive strengths of 3500 psi (24.1 MPa). FIRM-FILL® CMD is mixed on the job site with local sand (per ASTM C33) and water to create a lightweight slurry. A 1” (25 mm) application is required above the top of the flutes. Maximum thickness is 2“ (51 mm) in one lift. For residential and light commercial construction, FIRM-FILL® CMD is a cost-effective method to build higher and faster. FIRM-FILL® CMD creates a smooth, hard surface for finished floor coverings, while offering exceptional compressive strengths matched with superior acoustical control and fire resistance properties. For added sound isolation, use FIRM-FILL® CMD with a FIRM-FILL® SCM or Hacker Sound Mat.

Limitations When considering the use of this floor system, a licensed structural engineer shall first evaluate the building loads and framing system to determine whether this corrugated steel deck system is appropriate. FIRM-FILL® CMD is not a structural element and does not provide any contribution to the floor diaphragm. The corrugated steel deck shall be designed to address all floor diaphragm requirements and must conform to the Steel Deck Institute Standards. Reference SDI Manual of Construction with Steel Deck. For additional requirements, contact Hacker Industries, Inc. • Shall not be used in exterior locations, below grade or where continuous exposure to moisture is likely. • Shall not be used as a wear surface; must be covered by a finished floor covering. • Structure shall be designed so that deflection does not exceed L/360 live or dead load. Certain floor coverings, such as marble, limestone, travertine and wood, may have more restrictive deflection limits. Consult the appropriate floor covering manufacturer for recommendations. • No single application of FIRM-FILL® CMD shall exceed 2” in depth. • FIRM-FILL® CMD is one component of an effective sound and fire control system. Care must be taken in the installation of all components to assure the ultimate design performance. Published acoustical and fire system tests were conducted under controlled laboratory or field conditions and reflect results applicable only to those specific assemblies. 74

Hacker Industries, Inc. | Architect Binder | Firm-Fill® CMD | © 2017


SUBMITTAL FORM Installation Before, during and after the installation of FIRM-FILL® CMD, the building must be enclosed and the temperature maintained at a minimum of 50°F (10°C). Prior to the installation of FIRM-FILL® CMD, the subfloor shall be structurally sound (L/360) and be broom cleaned, dry and free from oil, grease, parrafin, laitance, wax or other contaminants. Prime the corrugated steel deck with FIRM-FILL® CMD Primer per recommended specifications before installing underlayment. Adequate ventilation shall be provided by the General Contractor (GC) to ensure proper drying of FIRM-FILL® CMD. If necessary, the GC shall provide mechanical ventilation. Depending on thickness and drying conditions, the underlayment should dry within 10 to 14 days. To avoid potential problems during the drying process, the GC shall consult Hacker Industries, Inc.’s Drying Conditions Flyer and information contained on Hacker Industries, Inc.’s website for additional information concerning drying of this product. After installation, temporary wood planking shall be placed by the GC wherever the floor underlayment will be subject to wheeled or concentrated loads. Finished floor coverings can be installed when the FIRM-FILL® CMD is completely dry. Consult flooring contractor for recommended procedures to test for dryness and acceptable levels of moisture. Reference Hacker Industries, Inc.’s Guidelines for Installing Finished Floor Coverings. This guideline is not a warranty and shall be used as a guideline only. See ASTM F2419.

Product Data Approximate Compressive Strength per ASTM C472 Modified: Approximate Dry Density (aggregated):

Minimum 3500 psi* (13.8 to 22.8 MPa) 107 to 120 pcf

*Note: Compressive strengths published herein were achieved under controlled laboratory conditions. Actual field results may differ due to environmental conditions, regional sand variations, or inconsistent proportioning of field-applied water, sand and Hacker Floor Underlayment, as well as differences in mixing/pumping equipment.

Compliance • ICC-ES ER-4147 • City of Los Angeles Research Report No. 24540

• FHA-HUD MR 1255 • Tile Council of North America (F180, F200, RH111, RH122)

Sound Test & UL Fire Rated Designs PURPOSE STATEMENT/DISCLAIMER These guidelines are designed to provide the architectural and building communities with detailed performance data on Hacker Industries, Inc.’s comprehensive portfolio of sound attenuation tests and UL Fire Rated Designs. The tests for the assemblies included in these guidelines were conducted in a laboratory setting per ASTM C177, E84, E90, E492 and E2179. These guidelines are not warranties and should be used as guidelines only. The architects’ and general contractors’ recommendations supersede these guidelines. Field performance may vary. Subject to express Warranty stated on Hacker Industries, Inc.’s website. Hacker Industries, Inc. regularly performs acoustical and fire (UL) testing to ensure performance standards for our products. Firm-Fill® gypsum concretes, including Firm-Fill® CMD, were tested acoustically with the following floor assemblies and performed as noted.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® CMD | © 2017

75


Hacker Industries, Inc.

Aco

SUBMITTAL FORM Corrugated Metal Deck

Sound System 1: Hacker Sound Mat II, 1” (25 mm) FIRM-FILL® CMD Gypsum Concr

Subfloor topping: 1” (25 mm) FIRM-FILL Subfloor isolation: 1/4” (6 mm) Hacker S Subfloor: 14 mm deep 22 msg galvanize Insulation: 3-1/2“ (89 mm) unfaced fiber Joist: Dietrich TradeReady 16 gauge met Ceiling isolation: Clark Dietrich RCSD res Ceiling: 1 layer 5/8” (16 mm) type C gyp

Contributes points to LEED® certifica Firm-Fill CMD – Corrugated Steel Deck Subfloor Topping 1” (25 mm) FIRMFILL® CMD Gypsum Concrete

Sound Mat 1/4" (6 mm) Hacker Sound Mat II

Subfloor

Insulation

Truss

Ceiling Isolation

Ceiling

Finish

Sound Rating

FINISH STC mm Quarry Tile Flooring over 1013mm 3-1/2" 13 Dietrich Clark 1 layer mmQT4010 61 (89 mm) 13 mm Quarry Dietrich 5/8" (16 Quarry Tile Tile Flooring over 10 mm QT4010 unfaced RCSD mm) type Flooring

14 mm deep 22 msg galvanized fiberglass corrugated batt fluting insulation steel decking

Resilient Channel

C gypsum board

Report #

--

STC IIC 61 -5008041 -58

58

7008100

IIC

REP 500 700

Over 10 mm QT4010

13 mm Quarry Tile Flooring Over 10 mm QT4010

--

Contributes points to LEED® certification.

UL Fire Rated Designs Steel Deck G230, G516, G524, G553, G561, G565, G566, G568, G587, G594, G595 Steel Joist L524, L527, L539, L543, L549, L551, L552, L564, M505, M511, M513, M515, M534

76

These guidelines shall only be a resource and are not a guarantee of performance. FIRM-FILL® SCM Underlayments are only one acoustical performance is affected by every other component. The likelihood of achieving code compliance is contingent upon ma plumbers and drywall contractors. DevelopersInc. and general contractors are responsible for building properly and testing field performa Hacker Industries, | Architect Binder | Firm-Fill® CMD | © 2017 of the project. Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design an a professional acoustical consultant to assure specifications are written correctly and that the floor/ceiling assembly can perform to ex


SUBMITTAL FORM Related Products FIRM-FILL® SCM sound control mats, FIRM-FILL® CMD Primer, Hacker TopCoat™ SP and Hacker Floor Sealer are available for use with FIRM-FILL® CMD Floor Underlayment. Contact Hacker Industries, Inc. at (800) 642-3455 or info@hackerindustries.com for more information.

Warranty Subject to express warranty stated on Hacker Industries, Inc.’s website.

Submittal Approvals Project Name

Contractor/Architect

Signature

Date

PRODUCT INFORMATION See www.HackerIndustries.com for current recommended product specifications and literature. WARNING When mixed with water, this product hardens and becomes extremely hot. DO NOT attempt to make a cast enclosing any part of the body using this material. Failure to follow these instructions may cause severe burns that may require surgical removal of affected tissue or amputation of limb. Portland cement is strongly alkaline. Direct contact can be corrosive and cause severe damage or chemical burns to eyes and wet, moist skin. Avoid contact with eyes and skin. Wear protective glasses and clothing. If eye contact occurs, immediately flush thoroughly with water for 30 minutes and seek medical advice. Inhalation of dust may be corrosive or cause chemical burns or irritation to nose, throat and respiratory tract. Avoid breathing dust. Use a NIOSH/MSHA-approved dust respirator. Wash thoroughly with soap and water after use. Do not ingest. If ingested, call a physician. Product safety, call (800) 642-3455. KEEP OUT OF REACH OF CHILDREN.

TRADEMARKS FIRM-FILL®, GYP-SPAN®, Let Our Products Floor You™ and the associated logos are trademarks of Hacker Industries, Inc. LEED® is a registered trademark of the U.S. Green Building Council. WARRANTY HACKER INDUSTRIES, INC. SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, DIRECTLY OR INDIRECTLY SUSTAINED, NOR FOR ANY LOSS CAUSED BY APPLICATION OF THESE GOODS NOT IN ACCORDANCE WITH CURRENT PRINTED INSTRUCTION OR FOR OTHER THAN THE INTENDED USE. OUR LIABILITY IS EXPRESSLY LIMITED TO REPLACEMENT OF DEFECTIVE GOODS. ANY CLAIM SHALL BE DEEMED WAIVED UNLESS MADE IN WRITING TO US WITHIN 30 DAYS FROM DATE IT WAS, OR REASONABLY SHOULD HAVE BEEN, DISCOVERED. SAFETY FIRST Follow good safety/industrial hygiene practices during installation. Wear appropriate personal protective equipment. Read specs, MSDS and literature prior to specification and installation. © 2017 Hacker Industries, Inc., Newport Beach, CA.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® CMD | © 2017

77


RECOMMENDED SPECIFICATIONS PART I: GENERAL 1.1

Scope

Specify to meet project requirements. The conditions of the Contract (General, Supplementary, and other conditions) and the General Requirements (sections of Division 1) govern the provisions of this section. 1.2

Qualifications

A.

Supplier: Hacker Industries, Inc., Newport Beach, California

B.

Installer: Installation of FIRM-FILL® CMD shall be by a trained Licensed Applicator of Hacker Industries, Inc., using mixing and pumping equipment with a water meter approved by Hacker Industries, Inc.

C.

All materials specified herein shall be approved by Hacker Industries, Inc., Newport Beach, CA. All others must receive prior approval.

D.

Compressive strength shall be specified at a minimum of 3500 psi (24.1 MPa).

E.

Materials shall be delivered in their original, unopened packages and protected from exposure to the elements before and after delivery. Do not allow bags to get wet. Product shall not be used beyond shelf life.

F.

Certification: Upon completion of this portion of the work, and as a condition of its acceptance, deliver to the architect a certificate from Hacker Industries, Inc., signed by the Licensed Applicator, stating that the material used in this work complies with the specified requirements.

PART II: PRODUCTS 2.1

Materials

A.

Gypsum Concrete: FIRM-FILL® CMD, as supplied by Hacker Industries, Inc.

B.

Subfloor Primer: FIRM-FILL® CMD Primer or equal

C.

Sand: 1/8” (3 mm) or less washed plaster, masonry sand or silica sand meeting requirements of Hacker Industries, Inc. Sand Guidelines

D.

Water: Potable and free from impurities

E.

Sealer: Hacker TopCoat™ SP (if specified)

2.2

Mix Design: See section 3.3

PART III: PREPARATION 3.1

Condition of Subfloor

A.

78

Subfloor shall be structurally sound (L/360), broom cleaned, dry and free from oil, grease, parrafin, laitance, wax or other contaminants before the arrival of the Hacker Licensed Applicator. Subfloor shall meet other applicable structural standards and be certified by a structural engineer.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® CMD | © 2017


RECOMMENDED SPECIFICATIONS (CONT.)

B.

Laps, where steel deck overlaps, are generally screwed together, and the deck is typically screwed to the joists. Maximum joist spacing shall be 24” on centers. Steel deck shall span across the joists, with deck ribs perpendicular to the joists. Contact a Hacker Industries, Inc. Licensed Applicator for additional questions regarding joists and laps.

C.

Leak Prevention: All cracks and voids should be filled with a quick-setting patching or taping compound, or equal, where leakage could occur.

D.

Before installation, the General Contractor (GC) shall inspect and approve the condition of the subfloor and check elevations.

3.2

Priming

Apply FIRM-FILL® CMD primer by pouring onto the deck and spreading out with a push broom at rate of 300 ft2/gal; do not thin. Primer may also be sprayed onto the deck, but it is imperative to achieve a continuous uniform coating. Allow 3 hours for adequate drying to a maximum of 24 hours before pouring the FIRM-FILL® CMD floor underlayment. Reference Hacker Industries, Inc.’s Priming Instructions for FIRM-FILL® CMD. 3.3

Mixing Instructions

A.

Add 80-pound (36.3 kg) bag of FIRM-FILL® CMD to 6 to 7 gallons (22.7 to 26.5 L) of water followed by the specific sand ratio. Do not overwater. Water amount will vary with the wetness of the sand.

This is the proper sequence for mixing of FIRM-FILL® CMD.

First add water to bucket followed by FIRM-FILL® CMD and finally the sand.

3.4

Underlayment Application

A.

Scheduling: 1. Installation of FIRM-FILL® CMD shall not begin until the building is enclosed, including roof, windows, doors and other openings.

2. FIRM-FILL® CMD must be installed before the installation of drywall.

B.

Application:

1. Minimum thickness of FIRM- FILL® CMD is 1” (25 mm) over the top of the flutes. Maximum thickness is 2” (51 mm).

2. Install FIRM-FILL® CMD at specified thickness by placing contents of bags, sand and water into the approved high-speed mixing device and blending for a minimum of one minute. FIRM-FILL® CMD shall be pumped onto floor areas, spreading and screeding to a smooth surface. Place as continuously as possible until installation is complete so that no FIRMFILL® CMD slurry is placed against FIRM-FILL® CMD that has obtained its initial set, except at authorized joints.

3. FIRM-FILL® CMD is suitable for interior applications only and must be covered by a finished floor covering.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® CMD | © 2017

79


RECOMMENDED SPECIFICATIONS (CONT.)

C.

Protection: After installation, temporary wood planking shall be placed by the GC wherever the floor underlayment will be subject to wheeled or concentrated loads. The GC shall not place concentrated loads—such as pallets of material, drywall, taping compounds or any heavy materials which may cause deflection—in the middle of the floor.

D.

Drying: Before, during and after installation of FIRM-FILL® CMD, building interior must be ventilated and heated to a minimum 50°F (10°C) to assure completion of the drying process. The GC shall supply mechanical ventilation, if necessary. Do not install finished floor coverings until the FIRM-FILL® CMD is tested for dryness. Consult flooring contractor for recommended procedures to test for dryness and acceptable levels of moisture. To avoid potential problems during the drying process, the GC shall consult Hacker Industries, Inc.’s Drying Conditions Flyer and information contained on Hacker Industries, Inc.’s website for additional information concerning drying of this product.

3.5

Preparation For Installation of Floor Coverings

A.

Sealing: Any areas where the underlayment surface has been damaged shall be cleaned and sealed regardless of floor covering specifified. Floor covering manufacturers’ specifications and requirements supersede these recommendations.

B.

Floor Covering Procedures: Please see Hacker Industries, Inc.’s Guidelines for Installing Finished Floor Coverings. The document is not a warranty and should be used as a guideline only.

3.6

Field Quality Control

A.

Slump Test: FIRM-FILL® CMD shall be tested for slump at the beginning of each installation in order to establish the required slump. Slump tests shall then be taken periodically during installation to verify that the required slump is maintained. Slump tests shall be conducted using a 2” by 4” (51 mm by 102 mm) cylinder. The acceptable patty size shall be 8-1/2” (216 mm) plus or minus 1/2” (approx. 13 mm) in diameter.

B.

Field Samples: Testing shall be done in accordance with ASTM C472 modified testing procedures using split brass molds. Prior to independent testing, consult Hacker Industries, Inc. for proper ASTM procedures.

Warranty: Subject to express warranty stated on Hacker Industries, Inc.’s website.

80

Hacker Industries, Inc. | Architect Binder | Firm-Fill® CMD | © 2017


PROJECT REFERENCES Designed for use in multi-family, commercial and institutional buildings with light-gauge steel framing and a corrugated steel deck, FIRM-FILL® CMD is a lightweight, high-strength gypsum concrete floor underlayment. Installed at 1” above the top of the flutes (1-9/16” total), FIRM-FILL® CMD reduces dead loads and thickness, significantly lowering costs. Below is a small sample of projects that have utilized FIRM-FILL® CMD. Contractor: Canan-Titan Joint Venture Project: Fort Riley, Building 216 Location: Fort Riley, Kansas Description: 4,782 ft² of FIRM-FILL® CMD Contractor: CBS Construction Project: Hutchinson Senior Care Center Location: Hutchinson, Minnesota Description: 120,000 ft² of FIRM-FILL® CMD Contractor: Choate Construction Company Project: Dogwood Forest Location: Acworth, Georgia Description: 87,000 ft² of FIRM-FILL® CMD Contractor: Colson & Colson Project: Glendale Retirement Center Location: Glendale, California Description: 41,580 ft² of FIRM-FILL® CMD Contractor: East Coast Builders Project: Holiday Inn Express Location: Havelock, North Carolina Description: 39,364 ft² of FIRM-FILL® CMD Contractor: Mosley Construction Project: Candlewood Suites Location: New Bern, North Carolina Description: 33,500 ft² of FIRM-FILL® CMD

Hacker Industries, Inc. | Architect Binder | Firm-Fill® CMD | © 2017

81


GYP-SPAN® RADIANT, a crack-resistant gypsum concrete is designed for use over hot water tubes or electric cables in radiant heat projects. Radiant tubes are locked in place with GYP-SPAN® RADIANT, providing a smooth, flat, warm surface ready for finished floor coverings. • Meets ASTM F2419, listed in TCNA Handbook • Efficient thermal mass for uniform heat transfer • No hot spots, air bubbles or shrinkage cracks • Compressive strengths up to 3200 psi • More than 100 UL Fire Rated Design Listings • Improves STC and IIC ratings • Installed by trained Licensed Applicators


1 14

4

15 2

17

16

1 - FLOOR COVERING / 2 - FIRM-FILL® GYPSUM CONCRETE UNDERLAYMENT / 4 - PLYWOOD / 14 - NAIL FLOORING TO PLYWOOD 15 - VAPOR BARRIER / 16 - SUBFLOOR / 17 - RADIANT TUBE

© 2017 Hacker Industries, Inc. FIRM-FILL® and the associated logos are trademarks of Hacker Industries, Inc., Newport Beach, CA.

0 psi

1000 psi

2000 psi

Firm-Fill® Gypsum Concrete Firm-Fill® 2010+ Firm-Fill® 3310+ Firm-Fill® High Strength

3000 psi

5000 psi

6000 psi

4000-5200 psi Firm-Fill® 4010+ min. 3500 psi Firm-Fill® CMD 2000-3200 psi Gyp-Span Radiant up to 6000 psi True-Screed CLU

1200-2000 psi 2000-3200 psi 3000-3900 psi 2500-3800 psi

1-1/2” TOTAL

4000 psi

2000-3200

3/4” > TUBES

For use over radiant heat systems; efficient thermal mass and no shrinkage

Requires 3/4” over top of tubes; total thickness of 1-1/2”

Provides compressive strengths from 2000 - 3200 psi (13.8 - 22 MPa)

Install with Hacker Sound Mat or FIRMFILL® SCM for additional isolation

Contributes points to LEED® project certification

Installed by Hacker Industries’ trained Licensed Applicators

Subfloor must be protected by vapor barrier if installed above crawl space

One component of an effective sound & fire control system

Wear appropriate personal protective equipment

L/360

Requires dryin (building must be fully enclosed before installation)

Not a wear surface; requires finished floor covering

Deflection must not exceed L/360 live or dead load

Hacker Industries, Inc. | Architect Binder | Gyp-Span® Radiant | © 2017

83


SUBMITTAL FORM TECHNICAL DATA

PROPERTIES

ASTM

Weight

14.6 lb/ft² (71.3 kg/m²) at 1-1/2” (38 mm)

C472 M

Thickness

3/4” (19 mm) over top tubes; 1-1/2” (38 mm) total thickness

Compressive Strength

2000 to 3200 psi (13.8 to 22 MPa)

C472 M

Thermal Performance

K-value of 2.8 BTU/(hr.ft.F°); R-value of 0.36 (ft².hr.F°)

C177

Fire Hazard Classification

Flamespread index 0: Fuel contribution 0; Smoke density 0

E84

Sand

1/8” (3 mm) or less washed plaster or masonry sand

C33

Flexural Strength

1300 psi (8.96 MPa)

C348

Benefits • • • • • • •

High-strength gypsum concrete for use over radiant heat systems Contributes to excellent STC and IIC ratings Efficient thermal mass for uniform heat distribution Lightweight and crack-resistant No hot spots, air bubbles or shrinkage cracks Helps contribute points to LEED® project certification Creates a flat, durable surface for finished floor coverings

Product Description GYP-SPAN® Radiant is specially formulated for use over hot water tubes or electric cables in radiant heat systems. The non-shrinking nature of GYP-SPAN® Radiant helps to lock radiant heat tubes in place, preventing noise and chafing, and evenly distributing the heat throughout the subfloor. GYP-SPAN® Radiant provides compressive strengths from 2000-3200 psi (13.8 to 22 MPa). Installed after drywall. GYP-SPAN® Radiant accepts virtually all types of floor coverings such as ceramic tile, carpeting and wood. GYP-SPAN® Radiant is mixed on the job site with local sand (per ASTM C33) and water to create a lightweight slurry. Installed at a minimum of 3/4” (19 mm) thick above the top of the tubes (total thickness of 1-1/2” [38 mm]), the underlayment weighs approximately 14.6 lb/ft² (71.3 kg/m²) with a dry density range of 105-120 pcf. For residential projects, GYP-SPAN® Radiant is a cost-efficient way to create a warm, flat and high-strength surface for finished floor coverings. To achieve additional sound isolation, use GYP-SPAN® Radiant with a Hacker Industries, Inc. sound mat.

Limitations • Do not use GYP-SPAN® Radiant in exterior locations, below grade or where continuous exposure to moisture is likely. • Shall not be used as a wear surface; must be covered by a finished floor covering. • Structure shall be designed so that deflection does not exceed L/360 live or dead load. Certain floor coverings, such as marble, limestone, travertine and wood, may have more restrictive deflection limits. Consult the appropriate floor covering manufacturer for recommendations. • If installed above a crawl space, subfloor must be protected by a vapor barrier. • No single application of GYP-SPAN® Radiant shall exceed 3” (76 mm) in depth. • GYP-SPAN® Radiant is one component of an effective sound and fire control system. Care must be taken in the installation of all components to assure the ultimate design performance. Published acoustical and fire system tests were conducted under controlled laboratory or field conditions and reflect results applicable only to those specific assemblies.

84

Hacker Industries, Inc. | Architect Binder | Gyp-Span® Radiant | © 2017


SUBMITTAL FORM Installation Before, during and after the installation of GYP-SPAN® Radiant, the building must be enclosed and the temperature maintained at a minimum of 50°F (10°C). Prior to the installation of GYP-SPAN® Radiant, the subfloor shall be structurally sound (L/360) broom cleaned, dry and free from oil, grease, paraffin, laitance, wax or other contaminants. Concrete subfloors shall be 28 days or older. For on-grade applications over concrete, measure the Moisture Vapor Emission Rate (MVER) per ASTM F1869. MVER shall not exceed 3 lb/1000 ft² per 24 hours. Prime wood subfloors per recommended specifications before installing GYP-SPAN® Radiant. Adequate ventilation shall be provided by the General Contractor (GC) to ensure proper drying of GYPSPAN® Radiant. If necessary, the GC shall provide mechanical ventilation. Depending on thickness and drying conditions, the underlayment should dry within 10 to 14 days. To avoid potential problems during the drying process, the GC shall consult Hacker Industries, Inc.’s Drying Conditions Flyer and information contained on Hacker Industries, Inc.’s website for additional information concerning drying of this product. After installation, temporary wood planking shall be placed by the GC wherever the floor underlayment will be subject to wheeled or concentrated loads. Finished floor coverings can be installed when the GYP-SPAN® Radiant is completely dry. Consult flooring contractor for recommended procedures to test for dryness and acceptable levels of moisture. Reference Hacker Industries, Inc.’s Guidelines for Installing Finished Floor Coverings. This guideline is not a warranty and shall be used as a guideline only. See ASTM F2419. For ceramic tile installations, a crack isolation membrane shall be used as recommended by setting material manufacturer.

Product Data Approximate Compressive Strength per ASTM C472 Modified: Approximate Dry Density (aggregated):

2000 to 3200 psi* (13.8 to 22 MPa) 105 to 120 pcf

*Note: Compressive strengths published herein were achieved under controlled laboratory conditions. Actual field results may differ due to environmental conditions, regional sand variations, or inconsistent proportioning of field-applied water, sand and Hacker Floor Underlayment, as well as differences in mixing/pumping equipment.

Compliance • ICC-ES ER-4147 • City of Los Angeles Research Report No. 24540

• FHA-HUD MR 1255 • Tile Council of North America (F180, F200, RH111, RH122)

UL Fire Rated Designs PURPOSE STATEMENT/DISCLAIMER These guidelines are designed to provide the architectural and building communities with detailed performance data on Hacker Industries, Inc.’s comprehensive portfolio of UL Fire Rated Designs. The tests for the assemblies included in these guidelines were conducted in a laboratory setting per ASTM C177 and E84. This guideline is not a warranty and should be used as a guideline only. The architects’ and general contractors’ recommendations supersede these guidelines. Field performance may vary. Subject to express Warranty stated on Hacker Industries, Inc.’s website. Hacker Industries, Inc. regularly performs fire (UL) testing to ensure performance standards for our products. Firm-Fill® gypsum concretes, including Gyp-Span® Radiant were tested under the following UL Fire Rated Designs.

Hacker Industries, Inc. | Architect Binder | Gyp-Span® Radiant | © 2017

85


SUBMITTAL FORM

UL Fire Rated Designs Nominal Wood L006, L201, L202, L206, L208, L209, L210, L211, L212, L501, L502, L503, L504, L505, L506, L507, L508, L509, L510, L511, L512, L513, L514, L515, L516, L517, L519, L520, L522, L523, L525, L526, L532, L533, L535 , L536, L537, L540, L541, L545, L557, L569, L588, L590, L593, L598, M504, M517, M519, M530, M531, M517 Open Web L521, L528, L529, L534, L542, L546, L550, L558, L563, L574, L576, L577, L579, L583, L585, L592, M500, M503, M508 I-Joist L518, L530, L538, L547, L556, L570, L581, L589, M502, M506, M512 Concrete J917, J919, J920, J924, J927, J931, J957, J991, J994

Related Products FIRM-FILL® SCM sound control mats, Hacker Floor Primer, Hacker TopCoat™ SP and Hacker Floor Sealer are available for use with GYP-SPAN® Radiant. Contact Hacker Industries, Inc. at (800) 642-3455 or info@ hackerindustries.com for more information.

Warranty Subject to express warranty stated on Hacker Industries, Inc.’s website.

Submittal Approvals Project Name

Contractor/Architect

Signature

Date

PRODUCT INFORMATION See www.HackerIndustries.com for current recommended product specifications and literature. WARNING When mixed with water, this product hardens and becomes extremely hot. DO NOT attempt to make a cast enclosing any part of the body using this material. Failure to follow these instructions may cause severe burns that may require surgical removal of affected tissue or amputation of limb. Portland cement is strongly alkaline. Direct contact can be corrosive and cause severe damage or chemical burns to eyes and wet, moist skin. Avoid contact with eyes and skin. Wear protective glasses and clothing. If eye contact occurs, immediately flush thoroughly with water for 30 minutes and seek medical advice. Inhalation of dust may be corrosive or cause chemical burns or irritation to nose, throat and respiratory tract. Avoid breathing dust. Use a NIOSH/MSHA-approved dust respirator. Wash thoroughly with soap and water after use. Do not ingest. If ingested, call a physician. Product safety, call (800) 642-3455. KEEP OUT OF REACH OF CHILDREN.

TRADEMARKS FIRM-FILL®, GYP-SPAN®, Let Our Products Floor You™ and the associated logos are trademarks of Hacker Industries, Inc. LEED® is a registered trademark of the U.S. Green Building Council. WARRANTY HACKER INDUSTRIES, INC. SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, DIRECTLY OR INDIRECTLY SUSTAINED, NOR FOR ANY LOSS CAUSED BY APPLICATION OF THESE GOODS NOT IN ACCORDANCE WITH CURRENT PRINTED INSTRUCTION OR FOR OTHER THAN THE INTENDED USE. OUR LIABILITY IS EXPRESSLY LIMITED TO REPLACEMENT OF DEFECTIVE GOODS. ANY CLAIM SHALL BE DEEMED WAIVED UNLESS MADE IN WRITING TO US WITHIN 30 DAYS FROM DATE IT WAS, OR REASONABLY SHOULD HAVE BEEN, DISCOVERED. SAFETY FIRST Follow good safety/industrial hygiene practices during installation. Wear appropriate personal protective equipment. Read specs, MSDS and literature prior to specification and installation. © 2017 Hacker Industries, Inc., Newport Beach, CA.

86

Hacker Industries, Inc. | Architect Binder | Gyp-Span® Radiant | © 2017


RECOMMENDED SPECIFICATIONS PART I: GENERAL 1.1

Scope

Specify to meet project requirements. The conditions of the Contract (General, Supplementary, and other conditions) and the General Requirements (sections of Division 1) govern the provisions of this section. 1.2

Qualifications

A.

Supplier: Hacker Industries, Inc., Newport Beach, California

B.

Installer: Installation of GYP-SPAN® Radiant shall be by a trained Licensed Applicator of Hacker Industries, Inc., using mixing and pumping equipment with a water meter approved by Hacker Industries, Inc.

C.

All materials specified herein shall be approved by Hacker Industries, Inc., Newport Beach, CA. All others must receive prior approval.

D.

Compressive strength can be specified from 2000-3200 psi (13.8 to 22.1 MPa).

E.

Materials shall be delivered in their original, unopened packages and protected from exposure to the elements before and after delivery. Do not allow bags to get wet. Product shall not be used beyond shelf life.

F.

Certification: Upon completion of this portion of the work, and as a condition of its acceptance, deliver to the architect a certificate from Hacker Industries, Inc., signed by the Licensed Applicator, stating that the material used in this work complies with the specified requirements.

PART II. PRODUCTS 2.1

Materials

A.

Gypsum Concrete: GYP-SPAN® Radiant, as supplied by Hacker Industries, Inc.

B.

Subfloor Primer: Hacker Floor Primer or approved equal

C.

Sand: 1/8” (3 mm) or less washed plaster, masonry sand or silica sand meeting requirements of Hacker Industries, Inc. Sand Guidelines

D.

Water: Potable and free from impurities

E.

Sealer: Hacker TopCoat™ SP (if specified)

2.2

Mix Design: See section 3.3

PART III: PREPARATION 3.1

Condition of Subfloor

A.

Subfloor shall be structurally sound (L/360), broom cleaned, dry and free from oil, grease, paraffin, laitance, wax or other contaminants before the arrival of the Hacker Licensed Applicator.

B.

Leak Prevention: All cracks and voids should be filled with a quick-setting patching or taping compound, or equal, where leakage could occur.

C.

Before installation, the General Contractor (GC) shall inspect and approve the condition of the subfloor and test the existing subfloor for moisture.

Hacker Industries, Inc. | Architect Binder | Gyp-Span® Radiant | © 2017

87


RECOMMENDED SPECIFICATIONS (CONT.) 3.2

Priming

A.

Prime wood subfloors with one coat of Hacker Floor Primer (diluted 4:1 with water) using one gallon of Hacker Floor Primer (3.78 L) per 500 ft2 (47 m2).

B.

Hacker Floor Primer is not always required over concrete substrates. Multiple coats may be required over porous concrete or plank. The Hacker Licensed Applicator can give specific recommendations. (Note: For rehabilitation work or pours over old and/or porous concrete, consult a Licensed Applicator or Hacker Industries, Inc. for recommended preparation.)

3.3 Mixing Instructions

A.

Add 80-pound (36.3 kg) bag of GYP-SPAN® Radiant to 6 to 7 gallons (22.7 to 26.5 L) of water followed by the specific sand ratio. Do not overwater. Water amount will vary with the wetness of the sand.

This is the proper sequence for mixing of GYP-SPAN® Radiant.

First add water to bucket followed by GYP-SPAN® Radiant and finally the sand.

3.4 Underlayment Application

A.

Scheduling: 1. Installation of GYP-SPAN® Radiant shall not begin until the building is enclosed, including roof, windows, doors and other openings.

2. GYP-SPAN® Radiant may be installed before or after the installation of drywall.

B.

Application: 1. The minimum thickness of GYP-SPAN® Radiant varies with the type of radiant tubing. Install the first lift (pour) to the top of the tubing or cable. After the first lift has set-up, install the second lift (pour) 3/4” (19 mm) above the first lift. The minimum thickness of GYP-SPAN® Radiant is 3/4” (19 mm) over the top of the tubes or cables.

2. Install GYP-SPAN® Radiant at specified thickness by placing contents of bags, sand and water into the approved high-speed mixing device and blending for a minimum of one minute. GYP-SPAN® Radiant shall be pumped onto floor areas, spreading and screeding to a smooth surface. Place as continuously as possible until installation is complete so that no GYP-SPAN® Radiant slurry is placed against GYP-SPAN® Radiant that has obtained its initial set, except at authorized joints. 3. GYP-SPAN® Radiant is suitable for interior applications only and must be covered by a finished floor covering.

C.

88

Protection: After installation, temporary wood planking shall be placed by the GC wherever the floor underlayment will be subjected to wheeled or concentrated loads. The GC shall not place concentrated loads—such as pallets of material, drywall, taping compounds or any heavy items which may cause deflection—in the middle of the floor or in hallways.

Hacker Industries, Inc. | Architect Binder | Gyp-Span® Radiant | © 2017


RECOMMENDED SPECIFICATIONS (CONT.) Drying: Before, during and after installation of GYP-SPAN® Radiant, building interior shall be ventilated and heated to a minimum 50°F (10°C) to assure completion of the drying process. The GC shall provide continuous ventilation and adequate heat to rapidly remove moisture from the area until the GYP-SPAN® Radiant is dry. If necessary, the GC shall provide mechanical ventilation. Do not install finished floor coverings until the GYP-SPAN® Radiant is tested for dryness. Consult flooring contractor for recommended procedures to test for dryness and acceptable levels of moisture. To avoid potential problems during the drying process, the GC shall consult Hacker Industries, Inc.’s Drying Conditions Flyer and information contained on Hacker Industries, Inc.’s website for additional information concerning drying of this product.

D.

3.5

Preparation For Installation of Floor Coverings

A.

Sealing: Any areas where the underlayment surface has been damaged shall be cleaned and sealed regardless of floor covering specified. Floor covering manufacturers’ specifications and requirements supercede these recommendations.

B.

For ceramic tile installations, a crack isolation membrane shall be used as recommended by setting material manufacturer for intended use or application. Reference TCNA.

C.

Floor Covering Procedures: Please see Hacker Industries, Inc.’s Guidelines for Installing Finished Floor Coverings. The guideline is not a warranty and should be used as a guideline only.

3.6

Field Quality Control

A.

Slump Test: GYP-SPAN® Radiant shall be tested for slump at the beginning of each installation in order to establish the required slump. Slump tests shall then be taken periodically during installation to verify that the required slump is maintained. Slump tests shall be conducted using a 2” by 4” (51 mm by 102 mm) cylinder. The acceptable patty size shall be 7-1/2” (191 mm) plus or minus 1/2” (13 mm) in diameter.

B.

Field Samples: Testing shall be done in accordance with ASTM modified C472 testing procedures, using split brass molds. Prior to independent testing, consult Hacker Industries, Inc. for proper ASTM procedures.

Warranty: Subject to express warranty stated on Hacker Industries, Inc.’s website.

Hacker Industries, Inc. | Architect Binder | Gyp-Span® Radiant | © 2017

89


PROJECT REFERENCES GYP-SPAN® Radiant is a high strength, crack-resistant gypsum concrete designed for use over hot water tubes or electric cables. GYP-SPAN® Radiant locks radiant tubes in place to evenly distribute heat throughout the floor, providing a smooth, flat and warm surface ready for finished floor coverings. Below is a small sample of projects that have utilized GYP-SPAN® Radiant. Contractor: Bonner, Inc. Project: Westmoreland Residence Location: Atlanta, Georgia Description: 4,472 ft² of GYP-SPAN® Radiant Contractor: Carolina Homes Project: Johnson Landing Condominiums Location: Red Deer, Alberta, Canada Description: Various projects with GYP-SPAN® Radiant Contractor: DLH Construction Project: Grace Residence Location: Williamsburg, Michigan Description: 2,600 ft² of GYP-SPAN® Radiant Contractor: Drury Construction Project: Buckman Residence Location: Malibu, California Description: 6,780 ft² of GYP-SPAN® Radiant Contractor: Fieldstone Development Project: Stonehaven at Brackenridge Golf Course Location: Breckenridge, Colorado Description: 30,000 ft² of GYP-SPAN® Radiant Contractor: Kurt Lloyd & Associates Project: Burnt Fork Log Home Location: Stevensville, Montana Description: 2,600 ft² of GYP-SPAN® Radiant Contractor: Liessmann Construction Project: Private Residence Location: Farmington, New Mexico Description: 3,400 ft² of GYP-SPAN® Radiant Contractor: Martel Construction Project: Lakeside Lodges Location: Big Sky, Montana Description: 70,000 ft² of GYP-SPAN® Radiant Contractor: PR Developments, Ltd. Project: Marion Chateau Senior’s Retirement Centre Location: Regina, Saskatchewan, Canada Description: 25,300 m² of GYP-SPAN® Radiant

90

Hacker Industries, Inc. | Architect Binder | Gyp-Span® Radiant | © 2017


Hacker Industries, Inc. D I V I S I O N 09 80 00 S O U N D T R E AT M E N T

FIRM-FILL速 SCM-125 FIRM-FILL速 SCM-250 FIRM-FILL速 SCM-400 FIRM-FILL速 SCM-750 Hacker Sound Mat II


FIRM-FILL® SCM-125 is a durable, lightweight sound control mat that provides a quieter environment and meets demanding project specifications. Install FIRM-FILL® SCM-125 under a FIRM-FILL® Gypsum Concrete Floor Underlyament to help produce an exceptional vibration isolation system. Create a quieter living environment and meet demanding project specifications in multi-family construction. Specify FIRM-FILL® SCM-125. • A thinner sound control mat for smoother transitions between hard surface and carpeted areas • Used in wood frame construction and a component of a well designed floor/ceiling assembly • Cost-effective way to address noise concerns and to improve IIC ratings • Minimal deflection, no creep or long term degradation • Specify with a FIRM-FILL® Gypsum Concrete Underlayment • Installed by trained Licensed Applicators


1 - FLOOR COVERING / 2 - FIRM-FILL® BRAND GYPSUM CONCRETE / 3 - FIRM-FILL® SCM-125 / 4 - PLYWOOD OR OSB / 5 - NOMINAL WOOD JOIST / 6 - BATT INSULATION / 7 - PARALLEL CHORD TRUSS / 8 - TJI ® JOIST / 9 - RESILIENT CHANNEL / 10 - GYPSUM WALLBOARD / 11 - 6” CONCRETE

Allows vapor pass- Class A fire-rated Improves Impact Improves Sound Performance in Installed only by Insulation Class Transmission Class through to prevent wood-frame and product Hacker Industries’ 6 - BATT INSULATION PARALLEL CHORD TRUSS (STC) / 8 - TJI ®ratings JOIST / 9 - RESILIENT CHANNEL / 10 - GYPSUM WALLBOARD / 11 - 6” CONCRETE structures / 7 -(IIC) trapped moisture ratings concrete Licensed Applicators

Compression Resistance

5000

3150

2000

1250

800

500

310

200

STC +

60 50 40 30

FIRM-FILL® SCM-125

FIRM-FILL® SCM-125

20

STC 52 Reference Contour

IC Contour

10

0

5000

3150

2000

1250

800

Robinson Wheel

500

310

200

125

L/360 Deflection must Do not use mechnot exceed L/360 anical fasteners Deflection must Do not use live or all dead load with Install FIRM-FILL® Tape seams not exceed L/360 Mechanical duct tape or 2” wide Brand Gypsum live or dead load Concrete Fasteners cellophane tape

Must be used with 80

moisture

0

50

4000

2500

1600

1000

630

400

250

160

Install isolation barrier around perimeter of floor

125

40

10

Frequency (Hz)

70

50

20

80

80

60

30

®

100

70

100

enclosed before installation)

30

90

structures

May not be used as a vapor barrier May not be used Install FIRM-FILL® as a vapor SCM-125 matbarrier with blue mesh down

40

80

Beginning Deflection Residual Requires Thickness dry-in During May not be used Deflection must Do not use mechLoad Thickness (building must be asImproves a vapor barrier exceed L/360 anical Performance Impact not Improves Sound Allows vapor to Frequency (Hz) fasteners fullyin enclosed or dead load wood-frame Insulation Class liveTransmission pass through to before installation) and concrete (IIC) ratings Class (STC) ratings prevent trapped

Requires dry-in (building must be Requires dryfully enclosed Install isolation in (building before barrierinstallation) around mustofbefloor fully perimeter

50

FIRM-FILL SCM-125 Class Installed only by 20 A fire-rated IC Contour 10 product Hacker Industries’ 0 Licensed Applicators

Frequency (Hz)

90

60

50

4000

0

2500

IIC +

Allows vapor passSTC 52 Reference Contour through to prevent trapped moisture 1600

20 Improves Sound 10 Transmission Class (STC) 0ratings

1000

42 lb/ft² 105 lb/ft² 505 lb/ft²

FIRM-FILL® SCM-125

630

0.3

0.1

30

400

0.4

0.2

40

Thickness

0.5

70

50

250

During Load

80

60

160

Thickness

Improves Impact Insulation Class (IIC) ratings Deflection Residual

90

70

100

in Performance 0.1 wood-frame and structures concrete 0 Beginning

© 2017 Hacker Industries, Inc. FIRM-FILL® and the associated logos are trademarks of Hacker Industries, Inc., Newport Beach, CA.

42 lb/ft² 105 lb/ft² 505 lb/ft²

0.2

100

80

Ln (dB)

0.3

90

Ln (dB)

0.4

Sound Transmission Loss (dB)

0.5

Sound Transmission Loss (dB)

Compression Resistance

1 - FLOOR COVERING / 2 - FIRM-FILL® BRAND GYPSUM CONCRETE / 3 - FIRM-FILL® SCM-125 / 4 - PLYWOOD OR OSB / 5 - NOMINAL WOOD JOIST / 6 - BATT INSULATION / 7 - PARALLEL CHORD TRUSS / ® BRAND ® 1 -® FLOOR / 2 - FIRM-FILL GYPSUM CONCRETE 8 - TJI JOIST / 9 COVERING - RESILIENT CHANNEL / 10 - GYPSUM WALLBOARD / 11 - 6” CONCRETE / 3 - FIRM-FILL SCM -125 / 4 - PLYWOOD OR OSB / 5 - NOMINAL WOOD JOIST

® Brand FIRM-FILL tested Extraby Heavy Class A Fire-rated Installed Frequency (Hz) Gypsum Concrete Hacker Duty Industries Product trained Licensed Applicators

Must be used with FIRM-FILL® Brand Must be used Gypsum Concrete Apply Hacker ® with FIRM-FILL TopCoat™ SP if Gypsum Concrete specified

Robinson Wheel tested Extra Heavy Robinson Wheel Duty Install finished floor Tested Extra covering only when Heavy Duty completely dry

© 09/2014 Hacker Industries, Inc. FIRM-FILL® and the associated logos are trademarks of Hacker Industries, Inc., Newport Beach, CA.

Install FIRM-FILL® SCM-125 mat with blue mesh down

Install isolation barrier around perimeter of floor

Install FIRM-FILL® SCM-125 mat with blue mesh down

Tape all seams with duct tape or 2” wide cellophane tape

Tape all seams with duct tape or 2” wide tape

Install FIRM-FILL® Brand Gypsum Concrete

Apply Hacker TopCoat™ SP if specified

Install finished floor covering only when completely dry

Install FIRM-FILL® Apply Hacker Install finished © 09/2014 Industries, Inc. ® SP Brand Gypsum TopCoat floorHacker covering FIRM-FILL and the associated logos are trademarks of Hacker Industries, Inc., Newport Beach, CA. Concrete when Specified only when completely dry ®

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-125 | © 2017

93


SUBMITTAL FORM TECHNICAL DATA Roll Weight Thickness Width Core Color Packaging Length Total Square Feet Effectiveness of Reducing IIC Sound Steiner Tunnel Test

PROPERTIES 33 lb (14 kg) 1/8 in (3 mm) nominal 60 in (152 cm) Blue 80 ft (24.5 m) 400 ft² (37.16 m²) ΔIIC 20.0` Class A

Benefits • • • • • • •

Thinner sound control mat for smoother transitions between hard surfaces and carpet Performance in wood frame construction and concrete structures Minimal deflection, no creep or long term degradation Cost-effective way to address noise concerns and to improve IIC ratings Class A fire-rated product Lightweight and easy to handle Installed only by trained Licensed Applicators across North America

Product Description FIRM-FILL® SCM-125 is a nominal 1/8” (3 mm), random filament, corrugated “U”- groove core sound control mat designed to limit impact noise between floors. Designed for critical applications in which FIRM-FILL® Gypsum Concrete will be utilized. FIRM-FILL® SCM-125 prevents liquid moisture from passing through to the substrate, an essential quality for wood frame construction. FIRM-FILL® SCM-125 is a Class A fire-rated product. Use in conjunction with a minimum 3/4” FIRM-FILL® Gypsum Concrete topping.

Limitations • Shall not be used in exterior locations, below grade or where continuous exposure to moisture is likely. • Shall not be used without a FIRM-FILL® Gypsum Concrete topping. • Structure shall be designed so that deflection does not exceed L/360 live or dead load. Certain floor coverings, such as marble, limestone, travertine and wood, may have more restrictive deflection limits. Consult the appropriate floor covering manufacturer for their recommendations. • Do not use mechanical fasteners to install FIRM-FILL® SCM-125, as mechanical fasteners conduct impact sound, reducing acoustical isolation. • FIRM-FILL® SCM-125 shall be installed with a perimeter isolation strip. • FIRM-FILL® SCM-125 is one component of an effective sound attenuation control system. Care must be taken in the installation of all components to ensure the ultimate design performance. Published acoustical and fire system tests were conducted under controlled laboratory and/or field conditions and reflected results are applicable only to those specific assemblies.

Installation Before, during and after installation, the building must be enclosed and the temperature maintained at a minimum of 50°F (10°C). Prior to installation, the subfloor shall be structurally sound (L/360), broom cleaned, dry and free from oil, grease, paraffin, laitance, wax or other contaminants.

94

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-125 | © 2017


SUBMITTAL FORM INSTALLATION(cont.) Attach perimeter isolation strip or approved alternative to the walls, conduit, flanges, ballasts, etc. in order to isolate or break the vibration transmission path between the floor and wall. Reinforcement is recommended in doorways and other high traffic or transition areas. FIRM-FILL® SCM-125 is laid directly over the concrete, plywood or OSB subfloor, with the blue mesh down and white fabric side up. It should be pushed up tightly to the isolation barrier. Alternately, the FIRM-FILL® SCM125 may be pushed up tightly to the gypsum wall board when the isolation barrier installed is FIRM-FILL® Perimeter Isolation. The gap between the floor and wall should not exceed 0.25” (6 mm). FIRM-FILL® SCM-125 edge must be placed adjacent to other pieces without any gap. Rolls are manufactured with the self-adhesive selvage edge folded over on the fabric top. When unrolled, the selvage edge remains in position. Starting at the base of the roll, smooth the selvage edge to the adjacent piece. If necessary, tape (duct tape or 2” [51 mm]-wide tape) the 3” (76 mm) fabric overlaps snug to the fabric on the adjoining FIRMFILL® SCM-125 strip. Tape all seams to prevent penetration into the core material during pour. Double tape seams if necessary. Finished floor coverings can be installed when the FIRM-FILL® Gypsum Concrete is completely dry. Consult flooring contractor for acceptable levels of moisture and recommended procedures to test for dryness. Reference Hacker Industries, Inc.’s Guidelines for Installing Finished Floor Coverings. This guideline is not a warranty and shall be used as a guideline only. See ASTM F2419.

Product Data Core Thickness: Roll Weight: Packaging Length: Core Width: Total square feet:

1/8 in (3 mm) nominal 33 lb (14 kg) 80 ft (24.5 m) 60 in (152 cm) 400 ft² (37.16 m²)

Sound Test & UL Fire Rated Designs PURPOSE STATEMENT/DISCLAIMER These guidelines are designed to provide the architectural and building communities with detailed performance data on Hacker Industries, Inc.’s comprehensive portfolio of sound attenuation tests and UL Fire Rated Designs. The tests for the assemblies included in these guidelines were conducted in a laboratory setting per ASTM C177, E84, E90, E492 and E2179. These guidelines are not warranties and should be used as guidelines only. The architects’ and general contractors’ recommendations supersede these guidelines. Field performance may vary. Subject to express Warranty stated on Hacker Industries, Inc.’s website. Hacker Industries, Inc. regularly performs acoustical and fire (UL) testing to ensure performance standards for our products. Firm Fill® SCM (sound control mats), including Firm Fill® SCM-125, were tested acoustically with the following floor assemblies and performed as noted.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-125 | © 2017

95


SUBMITTAL FORM

Subfloor: 23/32” oriented strand board; Insulation: None ² Assembly varies from above in the following: Subfloor topping: 1” FIRM-FILL® Brand Gypsum C Subfloor: 23/32” oriented strand board ³ Assembly varies from above in the following: Subfloor topping: 1” FIRM-FILL® Brand Gypsum C Subfloor: 23/32” oriented strand board; Insulation: 9” (229 mm) fiberglass batt insulation

Sound System 2: FIRM-FILL® SCM-125, 3/4” (19 mm) FIRM-FILL® Brand Gypsum Concrete

Subfloor topping: 3/4” (19 mm) FIRM-FILL® Br Subfloor isolation: 1/8” (3 mm) FIRM-FILL® SC Subfloor: 3/4” (19 mm) oriented strand board Insulation: 3-1/2” (89 mm) unfaced R-13 fiber Truss: 18” (457 mm) L/360 open web truss Ceiling isolation: Clark Dietrich RCSD resilient c Ceiling: 5/8” (16 mm) type C gypsum board FINISH• SCM-125 – Open Web Firm-Fill Subfloor Topping

Sound Mat

3/4” (19 mm) FIRMFILL® Brand Gypsum Concrete

1/8" (3 mm) FIRMFILL® SCM-125 Sound Control Mat

Subfloor InsulationBareTruss

Ceiling Isolation 2 mm Vinyl Plank

3/4" (19 mm) oriented strand board

Ceiling

STC Finish

3 mm Vinyl Tile 3-1/2" 18" Clark 5/8" Bare (89 mm) 2 mm (457Vinyl mm)Sheet Dietrich (16 mm) 2 mm Vinyl unfaced L/360 RCSD type C Plank 7 mm with Rubber Backing R-13 openSheet Vinyl Resilient gypsum fiberglass web truss Channel board 3 mm Vinyl insulation 13 mm Engineered Wood Tile 2 mm Vinyl Sheet

IIC

REPORT #

59 Sound -Rating 60 51 STC IIC 61 53 59 -58 51 60 51 59 57 61 53 59 57

D6435.01 Report #

58

51

D6435.02 D6435.03 D6435.01 D6435.04 D6435.02 D6435.05 D6435.03 D6435.06 D6435.04

These guidelines shall only be a resource and are not a guarantee of performance. FIRM-FILL® SCM Underlayments are only one compone 7 mm Sheet 57 D6435.05 acoustical performance is affected by every other component. The likelihood of achieving59 code compliance is contingent upon many other plumbers and drywall contractors. Developers and general contractors arewith responsible for building properly and testing field performance as soo Vinyl of the project. Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or cons Rubber a professional acoustical consultant to assure specifications are written correctly and that the floor/ceiling assembly can perform to expectation Backing ensure reliability of design prior to occupancy. © 2/2016 Hacker Industries, Inc. FIRM-FILL®, GYP-SPAN® and the associated logos are the re

13 mm 59 Engineered Wood 5

57

D6435.06

UL Fire Rated Designs Open Web L521, L528, L529, L534, L542, L546, L550, L558, L563, L574, L576, L577, L579, L583, L585, L592, M500, M503, M508

96

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-125 | © 2017


¹ Assembly varies from above in the following: Subfloor topping: 1” (25 mm) FIRM-FILL® Bran

SUBMITTAL FORM

Sound System 2: FIRM-FILL® SCM-125, 3/4” (19 mm) FIRM-FILL® Brand Gypsum Concre

Subfloor topping: 3/4” (19 mm) FIRM-FILL® Subfloor isolation: 1/8” (3 mm) FIRM-FILL® S Subfloor: 3/4” (19 mm) oriented strand board Insulation: 3-1/2” (89 mm) R-13 fiberglass in Joist: 9-1/4” (235 mm) 2x10 dimensional lum Ceiling isolation: Clark Dietrich RCSD resilien Ceiling: 5/8” (16 mm) type C gypsum board

Subfloor Topping

Sound Mat

Subfloor

3/4” (19 mm) FIRMFILL® Brand Gypsum Concrete

1/8" (3 mm) FIRMFILL® SCM-125 Sound Control Mat

3/4" (19 mm) oriented strand board

FINISH • Firm-Fill SCM-125 – Nominal Wood Bare Insulation Truss Ceiling Ceiling Isolation 2 mm Vinyl Plank

STC

IIC

59 Sound Rating 61 STC IIC 3 mm Vinyl Tile 61 3-1/2" 9-1/4" Clark 5/8" Bare 59 -(89 mm) Dietrich (16 mm) 2(235 mmmm) Vinyl Sheet 59 2 mm Vinyl 61 50 R-13 2x10 RCSD type C Plank 7 mm Sheet Vinyl with Rubber Backing 61 fiberglass Resilient gypsum insulation Channel board 3 mm Vinyl 61 52 13 mm Engineered Wood 61 Tile 8 mm Ceramic Tile 61 53 2 mm Vinyl 59 Sheet Finish

REPORT #

-- ReportE3145.01 # 50

E3145.02

52 E3145.03 E3145.01 53E3145.02 E3145.04 54 E3145.05 E3145.03 54 E3145.06 51E3145.04 E3145.07

7 mm Sheet Vinyl with Rubber Backing

61

54

E3145.05

13 mm

61

54

E3145.06

These guidelines shall only be a resource and are not a guarantee of performance. FIRM-FILL® SCM Underlayments are only one comp Engineered acoustical performance is affected by every other component.Wood The likelihood of achieving code compliance is contingent upon many oth plumbers and drywall contractors. Developers and general contractors are responsible for building properly and testing field performance as of the project. Laboratory tests are not a guarantee of field performance issues noted and many other design and/or co 8 mmbecause of the61 51 above E3145.07 a professional acoustical consultant to assure specifications are written correctly and that the floor/ceiling assembly can perform to expectat Ceramic ® ® ensure reliability of design prior to occupancy. © 2/2016 Hacker Industries, Inc. FIRM-FILL , GYP-SPAN and the associated logos are the

Tile

UL Fire Rated Designs

8

Nominal Wood L006, L201, L202, L206, L208, L209, L210, L211, L212, L501, L502, L503, L504, L505, L506, L507, L508, L509, L510, L511, L512, L513, L514, L515, L516, L517, L519, L520, L522, L523, L525, L526, L532, L533, L535 , L536, L537, L540, L541, L545, L557, L569, L588, L590, L593, L598, M504, M517, M519, M530, M531, M517

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-125 | © 2017

97


Hacker Industries, Inc.

Acoustica

I-JOIST

SUBMITTAL FORM

Subfloor Topping

Sound Mat

3/4” (19 mm) FIRMFILL® Gypsum Concrete

1/8" (3 mm) FIRMFILL® SCM-125 Sound Control Mat

Subfloor Topping

Sound Mat

3/4” (19 mm) FIRMFILL® Brand Gypsum Concrete

1/8" (3 mm) FIRMFILL® SCM-125 Sound Control Mat

Sound System 1: FIRM-FILL® SCM-125, 3/4” (19 mm) FIRM-FILL® Gypsum Concrete

Subfloor topping: 3/4” (19 mm) FIRM-FILL® Gyp Subfloor isolation: 1/8” (3 mm) FIRM-FILL® SCM Subfloor: 3/4” (19 mm) oriented strand board Insulation: 3-1/2” (89 mm) R-11 fiberglass insula Joist: 12” (302 mm) Weyerhaeuser Trus Joist® TJ Ceiling isolation: Clark Dietrich RCSD resilient ch Ceiling: 1 layer 5/8” (16 mm) type C gypsum boa

FINISH Firm-Fill• SCM-125 – I-Joist Bare Truss Subfloor Insulation Ceiling Ceiling Isolation 3 mm Vinyl Tile

STC

IIC

REPORT #

60 Sound -E7893.01 Report # Rating 62 51 E7893.03 STC IIC 7 mm Sheet Vinyl with Rubber Backing 61 55 E7893.05 3/4" 3-1/2" 12" Clark 1 layer Bare 60 -E7893.01 (19 mm) (89 mm)8 mm (302 mm) TileDietrich 5/8" Ceramic 61 -E7893.07 E7893.03 oriented R-11 RCSD (16 mm) 3 mm Vinyl 62 51 Tile strand fiberglass Resilient type C board insulation Channel gypsum 7 mm 61 55 E7893.05 board Sheet Vinyl with Rubber Backing ® ® Sound System 2: FIRM-FILL SCM-125, 3/4” (19 mm) FIRM-FILL Concrete 8 mm 61 -- Gypsum E7893.07 Ceramic Tile Subfloor topping: 3/4” (19 mm) FIRM-FILL® Bran Subfloor isolation: 1/8” (3 mm) FIRM-FILL® SCM Subfloor: 3/4” (19 mm) oriented strand board Firm-Fill• SCM-125 – I-Joist 2 (89 mm) R-11 fiberglass insula Subfloor Insulation Truss Ceiling Ceiling Insulation: Finish 3-1/2” Sound Report # ® Joist: 12” (302 mm) Weyerhaeuser Trus Joist TJ isolation Rating Ceiling isolation: Clark Dietrich RCSD resilient ch STC IIC Ceiling: 2 layers 5/8” (16 mm) type C gypsum bo 3/4" 3-1/2" 12" Clark 2 layers 2 mm Vinyl 61 53 E7893.09 (19 mm) (89 mm) (302 mm) Dietrich 5/8" Plank oriented R-11 RCSD (16 mm) FINISH IIC E7893.10 REPORT # 3 mm Vinyl STC-55 strand fiberglass Resilient type C Tile board insulation 2 mm Vinyl PlankChannel gypsum 61 53 E7893.09 board 2 mm Vinyl 61 54 E7893.11 Sheet 3 mm Vinyl Tile -55 E7893.10 Finish

7 mm 61 -Sheet 7 mm Sheet Vinyl with Rubber Backing Vinyl with -Rubber 13 mm Engineered Wood 61 Backing

59 54

E7893.12 E7893.11

59

E7893.12

59

E7893.13

61

59

2 mm Vinyl Sheet

13 mm

E7893.13

UL Fire Rated Designs I-Joist L518, L530, L538, L547, L556, L570, L581, L589, M502, M506, M512

These guidelines shall only be a resource and are not a guarantee of performance. FIRM-FILL® SCM Underlayments are only one component acoustical performance is affected by every other component. The likelihood of achieving code compliance is contingent upon many other trad plumbers and drywall contractors. Developers and general contractors are responsible for building properly and testing field performance as soon a of the project. Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or construc a professional acoustical consultant to assure specifications are written correctly and that the floor/ceiling assembly can perform to expectations. F ensure reliability of design prior to occupancy. © 2/2016 Hacker Industries, Inc. FIRM-FILL®, GYP-SPAN® and the associated logos are the regist

98

12 Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-125 | © 2017


6” (152 mm) CONCRETE ASSEMBLY

SUBMITTAL FORM

Subfloor Topping

Sound Mat

3/4” (19 mm) FIRM-FILL® Brand Gypsum Concrete

1/8" (3 mm) FIRM-FILL® SCM-125 Sound Control Mat

Sound System 1: FIRM-FILL® SCM-125, 3/4” (19 mm) FIRM-FILL® Brand Gypsum Concret

Subfloor topping: 3/4” (19 mm) FIRM-FILL® B Subfloor isolation: 1/8” (3 mm) FIRM-FILL® SC Subfloor: 6” (152 mm) concrete

FINISH Firm-Fill• SCM-125 – Concrete Assembly Subfloor InsulationBareTruss Ceiling Ceiling Isolation Bare 6" (152 mm) concrete

None

None

None

None

STC Finish

Bare

IIC

REPORT #

51 5014050 Sound -- Report # Rating -∆ 20* 7014090 STC IIC 51

5014050

--

-- Δ 20*® Brand 7014090 Sound System 2: FIRM-FILL® SCM-250,Bare 1” (25 mm) FIRM-FILL Gypsum Concrete

Subfloor topping: 1” (25) mm FIRM-FILL® Bra Subfloor isolation: 1/4” (6 mm) FIRM-FILL® SC Subfloor: 6” (152 mm) concrete UL Fire Rated Designs

Concrete J917, J919, J920, J924, J927, J931, J957, J991, J994 FINISH

STC

IIC

REPORT #

Bare

--

∆ 20*

7014143

*Tested in accordance with ASTM E2179 - Standard Test Method for Laboratory Measurement of Effectiveness of Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors. Bare 51 -5014075

Warranty

Submittal Approvals

Subject to express warranty stated on Hacker Industries, Inc.’s website.

Project Name

Contractor/Architect

Signature

Date

PRODUCT INFORMATION See www.HackerIndustries.com for current recommended product specifications and literature.

TRADEMARKS FIRM-FILL®, GYP-SPAN®, Let Our Products Floor You™ and the associated logos are trademarks of Hacker Industries, Inc. LEED® is a registered trademark of the U.S. Green Building Council.

FIRM-FILL® SCM-125, for use with Hacker Floor Underlayments, is a component in an overall floor/ceiling assembly. Its performance is WARRANTY affected by every other component and the likelihood of achieving code HACKER INDUSTRIES, INC. SHALL NOT BE LIABLE FOR INCIDENTAL compliance is contingent upon many other trades, including framers, OR CONSEQUENTIAL DAMAGES, DIRECTLY OR INDIRECTLY plumbers and drywall contractors. Developers and general contractors SUSTAINED, NOR FOR ANY LOSS CAUSED BY APPLICATION OF are responsible for building properly and testing field performance as THESE GOODS NOT IN ACCORDANCE WITH CURRENT PRINTED guidelines shall only be a resource and are a guarantee performance. FIRM-FILL® SCM Underlayments soon as possible in order to ensure the reliability of theThese project. INSTRUCTION ORnotFOR OTHERofTHAN THE INTENDED USE. HACKER'S are only one compon acoustical performance is affected by everyISother component.LIMITED The likelihood achieving code compliance is contingent upon many other LIABILITY EXPRESSLY TO of REPLACEMENT OF DEFECTIVE plumbers and drywall contractors. Developers generalSHALL contractors responsible for building properlyMADE and testing field performance as so WARNING GOODS. ANYand CLAIM BE are DEEMED WAIVED UNLESS of the project. Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or cons Laboratory tests are not a guarantee of field performance because of the IN WRITING TO HACKER INDUSTRIES, INC. WITHIN 30 DAYS FROM a professional acoustical consultant to assure specifications are written correctly and that the floor/ceiling assembly can perform to expectation issues noted above and many other design and/or construction errors DATE IT WAS, OR REASONABLY SHOULD HAVE BEEN, DISCOVERED. ensure reliability of design prior to occupancy. © 2/2016 Hacker Industries, Inc. FIRM-FILL®, GYP-SPAN® and the associated logos are the re that may occur. Please consult a professional acoustical consultant to ensure plans are proper and that the floor/ceiling assembly can perform SAFETY FIRST to expectations. Follow good safety/industrial hygiene practices during installation. Wear appropriate personal protective equipment. Read 16 specs, MSDS and literature prior to specification and installation. © 2017 Hacker Industries, Inc., Newport Beach, CA.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-125 | © 2017

99


RECOMMENDED SPECIFICATIONS PART I. GENERAL 1.1

Scope

The work of this section includes FIRM-FILL® SCM-125 to be placed under FIRM-FILL® Gypsum Concretes. 1.2

Qualifications

A. FIRM-FILL® SCM-125 shall be installed by trained Licensed Applicators of Hacker Industries, Inc.

B.

All materials specified herein shall be approved by Hacker Industries, Inc., Newport Beach, CA. All others must receive prior approval.

C.

Materials shall be delivered in their original, unopened containers with identification labels intact. Protect materials from exposure to harmful weather conditions and maintain at a minimum temperature of 50˚F (10˚C).

D.

Before, during and after installation the building interior shall be ventilated and heated to a minimum of 50°F (10°C) to assure completion of the drying process for the Hacker Floor Underlayment.

PART II. PRODUCTS 2.1

Product Description

FIRM-FILL® SCM-125 is a nominal 1/8” (3 mm), random filament, corrugated “U”- groove core sound control mat designed to limit impact noise between floors. Designed for critical applications in which FIRM-FILL® Gypsum Concrete will be utilized. FIRM-FILL® SCM-125 prevents liquid moisture from passing through to the substrate, an essential quality for wood frame construction. FIRM-FILL® SCM-125 is a Class A fire-rated product. Use with a minimum 3/4” FIRM-FILL® Gypsum Concrete topping. 2.2

Product Limitations

A.

Shall not be used in exterior locations, below grade or where continuous exposure to moisture is likely.

B.

Shall not be used without a FIRM-FILL® Gypsum Concrete topping.

C.

Structure shall be designed so that deflection does not exceed L/360 live or dead load. Certain floor coverings such as marble, limestone, travertine and wood may have more restrictive deflection limits. Consult the appropriate floor covering manufacturer for their recommendations.

D.

Do not use mechanical fasteners to install FIRM-FILL® SCM-125, as mechanical fasteners conduct impact sound, reducing acoustical isolation.

E. FIRM-FILL® SCM-125 shall be installed with a perimeter isolation strip.

F.

100

FIRM-FILL® SCM-125 is one component of an effective sound attenuation control system. Care must be taken in the installation of all components to ensure the ultimate design performance. Published acoustical and fire system tests were conducted under controlled laboratory or field conditions and reflect results applicable only to those specific assemblies.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-125 | © 2017


RECOMMENDED SPECIFICATIONS (CONT.)

PART III. PREPARATION 3.1

Condition of Subfloor

A.

Subfloor shall be structurally sound (L/360), broom clean, dry and free from oil, grease, paraffin, laitance, wax or other contaminants. Concrete substrate shall be 28 days or older.

B.

Leak prevention: All cracks and voids should be filled with a quick-setting patching or taping compound or equal where leakage may occur.

C.

Before installation, the GC shall inspect and approve the condition of the subfloor and test the existing subfloor for moisture.

3.2

Application

A.

Scheduling: Installation of FIRM-FILL® SCM-125 shall not begin until other trades are finished in the area. Protect FIRM-FILL® SCM-125 from trade traffic prior to application of FIRM-FILL® Gypsum Concretes.

B.

Installation

1. Perimeter Isolation Strip shall be properly installed in an “L” formation around areas where FIRM-FILL® SCM-125 will be installed, including any openings in the subfloor installation.

2. FIRM-FILL® SCM-125 is laid directly over the concrete, plywood or OSB subfloor, with the blue mesh down and white/blue fabric side up. It should be pushed up tightly to the isolation barrier that was previously installed around the perimeter of the floor; the gap between the floor and wall should not exceed 0.25“ (6 mm). Alternately, the FIRM-FILL® SCM-125 may be pushed up tightly to the gypsum wall board when the isolation barrier installed is FIRM-FILL® Perimeter Isolation. The gap between the floor and wall should not exceed 0.25” (6 mm). 3. FIRM-FILL® SCM-125 edge must be placed adjacent to other pieces without any gap. Rolls are manufactured with the self-adhesive selvage edge folded over on the fabric top. If necessary, tape (duct tape or 2” [51 mm]-wide tape) the 3” (76 mm) fabric overlaps snug to the fabric on the adjoining FIRM-FILL® SCM-125 strip. Tape all seams to prevent penetration into the core material during pour. Double tape seams if necessary. When unrolled, the selvage edge remains in that position. Starting at the base of the roll, smooth the selvage edge to the adjacent piece. 3.3

Application of FIRM-FILL® Brand Gypsum Concretes

A.

Taping and seams of FIRM-FILL® SCM-125 shall be checked and approved by the GC prior to the installation of FIRM-FILL® Gypsum Concretes.

B.

Install FIRM-FILL® Gypsum Concretes at a minimum thickness of 3/4” (19 mm).

C.

Protection: After installation, temporary wooden planking shall be placed by GC wherever the underlayment is subject to wheeled loads.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-125 | © 2017

101


D.

Drying: The GC shall provide continuous ventilation and adequate heat to rapidly remove moisture from the area until the underlayment is dry. If necessary, the GC shall provide mechanical ventilation and heat. Do not install finished floor coverings until the FIRM-FILL® Gypsum Concrete has been tested for dryness. Consult flooring contractor for recommended procedures to test for acceptable moisture levels. To avoid potential problems during the drying process, the GC shall consult Hacker Industries, Inc.’s Drying Conditions Flyer and Hacker Industries, Inc.’s website for additional information.

3.4

Preparation for Installation of Floor Coverings

A.

Sealing: Any areas where the underlayment surface has been damaged shall be cleaned and sealed. The floor covering manufacturer’s specificatiions and requirements suspersede these recommendations.

B.

Floor Covering Procedures: See Hacker Industries, Inc.’s Guidelines for Installing Finished Floor Coverings. The guideline is not a warranty and shall be used as a guideline only. See ASTM F2419.

C.

After finished floor covering is installed, trim the perimeter isolation strip below the finished flooring. Fill the groove with a bead of acoustical sealant or elastomeric sealant. Do not allow ceramic tile, grout or FIRM-FILL® Gypsum Concrete to come in contact with the wall. Shim the molding above the finished floor covering and caulk with an acoustical sealant.

3.5

Field Quality Control

Sound tests on underlayment systems have been conducted under laboratory and field conditions. Contact Hacker Industries, Inc. at (800) 642-3455 for information. Note: Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or construction errors that may occur. Please consult a professional acoustical consultant to ensure plans are proper and that the floor/ceiling assembly can perform to expectations.

Warranty: Hacker Industries, Inc. warrants Hacker Floor Underlayments (HFU) to be free from manufacturing defects, and when properly prepared and installed according to approved specified methods, HFU will attain minimum physical specifications as stated by Hacker Industries, Inc.’s most recent literature. Hacker Industries, Inc.’s obligation shall be limited to the replacement of the bagged product only and is subject to notice and inspection requirements. This warranty is in lieu of all other warranties, express or implied, including the warranties of merchantability and fitness for a particular purpose and all other obligations or liabilities.

102

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-125 | © 2017


When demanding consistent quality, specify FIRM-FILL® SCM-250 to assist in achieving highly improved IIC sound performance in multifamily construction. FIRM-FILL® SCM-250 is an integral component of a well designed floor/ ceiling assembly. FIRM-FILL® SCM-250 may be installed under a FIRM-FILL® Gypsum Concrete Floor Underlayment to produce an exceptional vibration isolation floor system. • Assists in achieving improved IIC sound performance • Integral component of a well designed floor/ceiling assembly • Performs well in wood frame construction and concrete structures • Minimal deflection, no creep or long term degradation • Lightweight and easy to install • Installed by trained Licensed Applicators


1 - FLOOR COVERING / 2 - FIRM-FILL® BRAND GYPSUM CONCRETE / 3 - FIRM-FILL® SCM-250 / 4 - PLYWOOD OR OSB / 5 - NOMINAL WOOD JOIST / 6 - BATT INSULATION / 7 - PARALLEL CHORD TRUSS / 8 - TJI ® JOIST / 9 - RESILIENT CHANNEL / 10 - GYPSUM WALLBOARD / 11 - 6” CONCRETE

Improves Impact Improves Sound Allows vapor pass- Class A fire-rated Performance in Installed only by Insulation Class Transmission Class through to prevent wood-frame and product Hacker Industries’ 6 - BATT INSULATION PARALLEL CHORD TRUSS (STC) / 8 - TJI ®ratings JOIST / 9 - RESILIENT CHANNEL / 10 - GYPSUM WALLBOARD / 11 - 6” CONCRETE structures / 7 -(IIC) ratings trapped moisture concrete Licensed Applicators

Compression Resistance

5000

3150

2000

1250

800

500

80

310

200

125

80

70

Frequency (Hz)

70

60 50 40

10

®

100 90

20

40 30

80

30

50

FIRM-FILL SCM-250 Class20A fire-rated Installed only by IC Contour 10 product Hacker Industries’ 0 Licensed Applicators

Frequency (Hz)

90

60

50

4000

2500

STC +

50 40 30

FIRM-FILL® SCM-250 STC 52 Reference Contour

0

IC Contour

10 0

5000

3150

2000

1250

Robinson Wheel 800

500

310

200

Must be used with 125

moisture

FIRM-FILL® SCM-250

20

80

4000

2500

1600

1000

630

400

250

160

100

Beginning Deflection RequiresThickness dry-in During May Residual not be used Deflection must Do not use mechLoad Thickness (building must be asImproves a vapor barrier exceed L/360 anical fasteners Frequency (Hz) Performance Impact not Improves Sound Allows vapor to fullyin enclosed or dead load wood-frame Insulation Class liveTransmission pass through to before installation) and concrete (IIC) ratings Class (STC) ratings prevent trapped

structures

60

50

0

1600

0.1

Allows vapor passSTC 52 Reference Contour through to prevent trapped moisture 1000

IIC +

0.2

FIRM-FILL® SCM-250

630

42 lb/ft² 105 lb/ft² 505 lb/ft²

30

400

0.3

40

20 Improves Sound 10 Transmission Class 0 (STC) ratings

Thickness

0.4

70

50

250

During Load

0.5

80

60

160

Thickness

Improves Impact Insulation Class (IIC) ratings Deflection Residual

90

70

100

in Performance 0.1 wood-frame and concrete 0 structures Beginning

© 2017 Hacker Industries, Inc. FIRM-FILL® and the associated logos are trademarks of Hacker Industries, Inc., Newport Beach, CA.

42 lb/ft² 105 lb/ft² 505 lb/ft²

0.2

100

80

Ln (dB)

0.3

90

Ln (dB)

0.4

Sound Transmission Loss (dB)

0.5

Sound Transmission Loss (dB)

Compression Resistance

1 - FLOOR COVERING / 2 - FIRM-FILL® BRAND GYPSUM CONCRETE / 3 - FIRM-FILL® SCM-250 / 4 - PLYWOOD OR OSB / 5 - NOMINAL WOOD JOIST / 6 - BATT INSULATION / 7 - PARALLEL CHORD TRUSS / ® BRAND ® 1®-JOIST FLOOR / 2 - FIRM-FILL GYPSUM 8 - TJI / 9 - COVERING RESILIENT CHANNEL / 10 - GYPSUM WALLBOARD / 11 - 6”CONCRETE CONCRETE / 3 - FIRM-FILL SCM -250 / 4 - PLYWOOD OR OSB / 5 - NOMINAL WOOD JOIST

® Brand FIRM-FILL Extraby Heavy Frequencytested (Hz) Class A Fire-rated Installed Gypsum Concrete Hacker Duty Industries Product trained Licensed Applicators

L/360 Requires dry-in May not be used Deflection must Do not use mechMust be used with Robinson Wheel (building must be as a vapor barrier not exceed L/360 anical fasteners FIRM-FILL® Brand tested Extra Heavy Requires MayFIRM-FILL not be used Deflection must DoFIRM-FILL not use ® Gypsum MustHacker be used Robinson Wheel ® Install isolationdry- Install Tape all seams with Install Apply Install finished floor Concrete fully enclosed live or dead load Duty ® in (building as a vapor barrier not exceed L/360 Mechanical with FIRM-FILL tested Extra barrier around SCM-250 mat with duct tape or 2” wide Brand Gypsum TopCoat™ SP if covering only when before installation) mustofbefloor fully blue mesh down live or dead load Concrete Fasteners Gypsum Heavy Duty perimeter cellophane tape specifiedConcrete completely dry

enclosed before installation)

Install isolation barrier around perimeter of floor

© 09/2014 Hacker Industries, Inc. FIRM-FILL® and the associated logos are trademarks of Hacker Industries, Inc., Newport Beach, CA.

Install FIRM-FILL® SCM-250 mat with blue mesh down

Install isolation barrier around perimeter of floor 104

Install FIRM-FILL® SCM-250 mat with red mesh down

Tape all seams with duct tape or 2” wide cellophane tape

Tape all seams with duct tape or 2” wide tape

Install FIRM-FILL® Brand Gypsum Concrete

Apply Hacker TopCoat™ SP if specified

Install finished floor covering only when completely dry

Install FIRM-FILL® Apply Hacker Install finished © 09/2014 Hacker Industries, Inc. ® SP Gypsum Concrete TopCoat floor covering FIRM-FILL and the associated logos are trademarks of Hacker Industries, Inc., Newport Beach, CA. when Specified only when completely dry ®

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-250 | © 2017


SUBMITTAL FORM TECHNICAL DATA Roll Weight Thickness Width Core Color Packaging Length Total Square Feet Effectiveness of Reducing IIC Sound Steiner Tunnel Test

PROPERTIES 39 lb (17.7 kg) 1/4 in (6 mm) nominal 58.5 in (149 cm) Red 80 ft (24.5 m) 400 ft² (37.16 m²) ΔIIC 20.0` Class A

Benefits • • • • • •

Assists in achieving improved IIC sound performance Integral component of a well designed floor/ceiling assembly Minimal deflection, no creep or long term degradation Performance in wood frame construction and concrete structures Lightweight and easy to install Installed only by trained Licensed Applicators across North America

Product Description FIRM-FILL® SCM-250 is a nominal 1/4” (6 mm), random filament, corrugated “U”- groove core sound control mat designed to limit impact noise between floors. Designed for critical applications in which FIRM-FILL® Gypsum Concrete will be utilized. FIRM-FILL® SCM-250 prevents moisture from passing through to the substrate, an essential quality for wood frame construction. FIRM-FILL® SCM-250 is a Class A fire-rated product. Use in conjunction with a minimum 1” FIRM-FILL® Gypsum Concrete topping.

Limitations • Shall not be used in exterior locations, below grade or where continuous exposure to moisture is likely. • Shall not be used without a FIRM-FILL® Brand Gypsum Concrete topping. • Structure shall be designed so that deflection does not exceed L/360 live or dead load. Certain floor coverings, such as marble, limestone, travertine and wood, may have more restrictive deflection limits. Consult the appropriate floor covering manufacturer for their recommendations. • Do not use mechanical fasteners to install FIRM-FILL® SCM-250 as mechanical fasteners conduct impact sound, reducing acoustical isolation. • FIRM-FILL® SCM-250 shall be installed with a perimeter isolation strip. • FIRM-FILL® SCM-250 is one component of an effective sound attenuation control system. Care must be taken in the installation of all components to ensure the ultimate design performance. Published acoustical and fire system tests were conducted under controlled laboratory and/or field conditions and reflected results are applicable only to those specific assemblies.

Installation Before, during and after installation, the building must be enclosed and the temperature maintained at a minimum of 50°F (10°C). Prior to installation, the subfloor shall be structurally sound (L/360), broom cleaned, dry and free from oil, grease, paraffin, laitance, wax or other contaminants. Attach perimeter isolation strip or approved alternative to the walls, conduit, flanges, ballasts, etc. in order to isolate or break the vibration transmission path between the floor and wall. Reinforcement is recommended in doorways and other high traffic or transition areas. Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-250 | © 2017

105


SUBMITTAL FORM INSTALLATION (cont.) FIRM-FILL® SCM-250 is laid directly over the concrete, plywood or OSB subfloor, with the red mesh down and white/red fabric side up. It should be pushed up tightly to the isolation barrier. Alternately, the FIRM-FILL® SCM-250 may be pushed up tightly to the gypsum wall board when the isolation barrier installed is FIRM-FILL® Perimeter Isolation. The gap between the floor and wall should not exceed 0.25” (6 mm). FIRM-FILL® SCM-250 edge must be placed adjacent to other pieces without any gap. Rolls are manufactured with the self-adhesive selvage edge folded over on the fabric top. When unrolled, the selvage edge remains in position. Starting at the base of the roll, smooth the selvage edge to the adjacent piece. If necessary, tape (duct tape or 2” [51 mm]-wide tape) the 3” (76 mm) fabric overlaps snug to the fabric on the adjoining FIRMFILL® SCM-250 strip. Tape all seams to prevent penetration into the core material during pour. Double tape seams if necessary. Finished floor coverings can be installed when the FIRM-FILL® Gypsum Concrete is completely dry. Consult flooring contractor for acceptable levels of moisture and recommended procedures to test for dryness. Reference Hacker Industries, Inc.’s Guidelines for Installing Finished Floor Coverings. This guideline is not a warranty and shall be used as a guideline only. See ASTM F2419.

Product Data Core Thickness: Roll Weight: Packaging Length: Core Width: Total square feet:

1/4 in (6 mm) nominal 39 lb (17.7 kg) 80 ft (24.5 m) 58.5 in (149 cm) 400 ft² (37.16 m²)

Sound Test & UL Fire Rated Designs PURPOSE STATEMENT/DISCLAIMER These guidelines are designed to provide the architectural and building communities with detailed performance data on Hacker Industries, Inc.’s comprehensive portfolio of sound attenuation tests and UL Fire Rated Designs. The tests for the assemblies included in these guidelines were conducted in a laboratory setting per ASTM C177, E84, E90, E492 and E2179. These guidelines are not warranties and should be used as guidelines only. The architects’ and general contractors’ recommendations supersede these guidelines. Field performance may vary. Subject to express Warranty stated on Hacker Industries, Inc.’s website. Hacker Industries, Inc. regularly performs acoustical and fire (UL) testing to ensure performance standards for our products. Firm Fill® SCM (sound control mats), including Firm Fill® SCM-250, were tested acoustically with the following floor assemblies and performed as noted.

106

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-250 | © 2017


Hacker Industries, Inc.

SUBMITTAL FORM

Sound System 3: FIRM-FILL® SCM-250, 1” (25 mm) FIRM-FILL® Brand Gypsum Concrete

OPEN WEB

Subfloor Topping

Sound Mat

1” (25 mm) FIRMFILL® Brand Gypsum Concrete

1/4" (6 mm) FIRMFILL® SCM-250 Sound Control Mat

Subfloor topping: 1” (25 mm) FIRM-FILL® Bra Subfloor isolation: 1/4” (6 mm) FIRM-FILL® SC Subfloor: 3/4” (19 mm) oriented strand board Insulation: 3-1/2” (89 mm) unfaced R-13 fiber Truss: 18” (457 mm) L/360 open web truss Ceiling isolation: Clark Dietrich RCSD resilient Ceiling: 5/8” (16 mm) type C gypsum board

FINISHSCM-250® – Open Web 1 Firm-Fill Subfloor InsulationBareTruss Ceiling Ceiling Isolation 2 mm Vinyl Plank 3/4" (19 mm) oriented strand board

Acousti

STC

IIC

REPORT #

60 D6435.22 Sound 50 Report # Rating 62 53 D6435.23 STC IIC 3 mm Vinyl Tile 61 53 D6435.24 3-1/2" 18" Clark 5/8" Bare 60 50 D6435.22 (89 mm) 2 mm (457Vinyl mm) Sheet Dietrich (16 mm) 61 53 54 D6435.23 D6435.25 2 mm Vinyl 62 unfaced L/360 RCSD type C Plank R-13 openSheet Vinyl Resilient gypsum 7 mm with Rubber Backing 59 58 D6435.26 fiberglass web truss Channel board 3 mm Vinyl 61 53 D6435.24 61 57 D6435.27 insulation 13 mm Engineered Wood Tile 8 mm Ceramic Tile

Finish

2 mm Vinyl Sheet

60 61

D6435.28 54 50 D6435.25

7 mm 59 58 D6435.26 Sheet Vinyl with Sound System 4: FIRM-FILL® SCM-250,Rubber 1” (25 mm) FIRM-FILL® Brand Gypsum Concrete Backing topping: 1” (25D6435.27 mm) FIRM-FILL® Bra 13 Subfloor mm 61 57 Subfloor isolation: 1/4” D6435.28 (6 mm) FIRM-FILL® SC 8 mm 60 50 Subfloor: 3/4” (19 mm) oriented strand board Ceramic TileInsulation: 3-1/2” (89 mm) unfaced R-13 fiber Truss: 18” (457 mm) L/360 open web truss Ceiling isolation: PAC International RSIC-1 and Firm-Fill SCM-250® – Open Web 2 Ceiling: 5/8” (16 mm) type C gypsum board Subfloor Topping

1” (25 mm) FIRMFILL® Brand Gypsum Concrete

Sound Mat

Subfloor

Insulation

Truss

FINISH 1/4" (6 mm) FIRMFILL® SCM-250 Sound Control Mat

3/4" (19 mm) oriented strand board

3-1/2" (89 mm) unfaced R-13 fiberglass

Ceiling Isolation

Bare 18" PAC 2(457 mmmm) Vinyl Plank L/360 3open mm Vinyl Tile web 2 mmtruss Vinyl Sheet

Ceiling

Sound

Rating STC STC

5/8" (16 mm) type C gypsum board

13 mm Engineered Wood 8 mm Ceramic Tile

Finish

Bare 2 mm Vinyl Plank 3 mm Vinyl Tile 2 mm Vinyl Sheet 13 mm 8 mm Ceramic Tile

Report #

IIC

REPORT #

IIC

62 53 F4545.01 62 53 F4545.01 62 56 F4545.02 62 56 F4545.02 62 56 F4545.03 62 56 F4545.03 62 56 F4545.04 62 56 60 F4545.04 F4545.05 62 61 57 F4545.06 62 60 F4545.05 61

57

F4545.06

These guidelines shall only be a resource and are not a guarantee of performance. FIRM-FILL® SCM Underlayments are only one compon acoustical performance is affected by every other component. The likelihood of achieving code compliance is contingent upon many other plumbers and drywall contractors. Developers and general contractors are responsible for building properly and testing field performance as so of the project. Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or cons UL acoustical Fire Rated Designs a professional consultant to assure specifications are written correctly and that the floor/ceiling assembly can perform to expectation ensure reliability of design prior to occupancy. © 2/2016 Hacker Industries, Inc. FIRM-FILL®, GYP-SPAN® and the associated logos are the re

Open Web L521, L528, L529, L534, L542, L546, L550, L558, L563, L574, L576, L577, L579, L583, L585, L592, M500, M503, M508 6 Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-250 | © 2017

107


Hacker Industries, Inc.

NOMINAL WOOD

SUBMITTAL FORM

Subfloor Topping

Sound Mat

1” (25 mm) FIRMFILL® Brand Gypsum Concrete

1/4" (6 mm) FIRMFILL® SCM-250 Sound Control Mat

Sound System 3: FIRM-FILL® SCM-250, 1” (25 mm) FIRM-FILL® Brand Gypsum Concrete

Subfloor topping: 1” (25 mm) FIRM-FILL® Bra Subfloor isolation: 1/4” (6 mm) FIRM-FILL® S Subfloor: 3/4” (19 mm) oriented strand board Insulation: 3-1/2” (89 mm) R-13 fiberglass in Joist: 9-1/4” (235 mm) 2x10 dimensional lum Ceiling isolation: Clark Dietrich RCSD resilient Ceiling: 5/8” (16 mm) type C gypsum board

FINISH Firm-Fill SCM-250® – Nominal Wood Bare Subfloor Insulation Truss Ceiling Ceiling Isolation 2 mm Vinyl Plank 3/4" (19 mm) oriented strand board

Acousti

STC

IIC

59 Sound Rating 59 STC IIC 3 mm Vinyl Tile 60 3-1/2" 9-1/4" Clark 5/8" Bare 59 -mm mm) Vinyl Sheet 59 (89 mm) 2 (235 Dietrich (16 mm) 2 mm Vinyl 59 50 R-13 2x10 RCSD type C Plank 7 mm Sheet Vinyl with Rubber Backing 58 fiberglass Resilient gypsum insulation 13 mm Engineered Channel board 3 mm Vinyl 60 Wood 60 50 Tile 8 mm Ceramic Tile 60 51 2 mm Vinyl 59 Sheet Wood Laminate¹ 59 Finish

Wood Laminate²

7 mm Sheet Vinyl with Rubber Backing

Wood Laminate²

13 mm

Wood Laminate¹ Carpet and Pad²

58 --

56

51 58 60 -60

REPORT #

--

E3146.01 Report # 50 E3146.02

50

E3146.03 E3146.01 51 E3146.04 E3146.02 56 E3146.05 54 E3146.03 E3146.06

51 E3146.04 E3146.07 --

5013115 E3146.05 56 7013170 --

5013113

-5013114 54 50 E3146.06 7013168 51 E3146.07

8 mm Ceramic ¹ Assembly varies from above in the following: Tile Subfloor: 5/8” (16 mm) oriented strand board

² Assembly varies from above in the following: Subfloor: 5/8” (16 mm) oriented strand board; C Wood 59 -5013115 Cemco RC channel

Laminate¹ Wood Laminate¹

--

56

7013170

Carpet and Pad²

51

--

5013113

Wood Laminate²

58

--

5013114

Wood Laminate²

--

50

7013168

¹Assembly varies from above in the following: Subfloor: 5/8” (16 mm) oriented strand board ²Assembly varies from above in the following: Subfloor: 5/8” (16 mm) oriented strand board; ceiling isolation: Cemco RC channel

UL Fire Rated Designs

Nominal Wood L006, L201, L202, L206, L208, L209, L210, L211, L212, L501, L502, L503, L504, L505, L506, L507, L508, L509, L510, L511, L512, L513, L514, L515, L516, L517, L519, L520, L522, L523, ®L525, L526, These guidelines shall only be a resource and are not a guarantee of performance. FIRM-FILL SCM Underlayments are only one compo L532, L533, L535 , L536, L537, L540, L541, L545, L557, L569, L588, L590, L593, L598, M504, acoustical performance is affected by every other component. The likelihood of achieving code compliance is contingent upon many othe M517, M519, M530,plumbers M531,and M517 drywall contractors. Developers and general contractors are responsible for building properly and testing field performance as s

of the project. Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or con a professional acoustical consultant to assure specifications are written correctly and that the floor/ceiling assembly can perform to expectatio ensure reliability of design prior to occupancy. © 2/2016 Hacker Industries, Inc. FIRM-FILL®, GYP-SPAN® and the associated logos are the

9 108

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-250 | © 2017


Hacker Industries, Inc.

I-JOIST

SUBMITTAL FORM

Subfloor Topping 1” (25 mm) FIRMFILL® 2010+ Gypsum Concrete

Sound Mat 1/4" (6 mm) FIRMFILL® SCM-250 Sound Control Mat

Sound System 3: FIRM-FILL® SCM-250, 1” (25 mm) FIRM-FILL® 2010+ Gypsum Concrete

Subfloor topping: 1” (25 mm) FIRM-FILL® 2010+ Subfloor isolation: 1/4” (6 mm) FIRM-FILL® SCM Subfloor: 3/4” (19 mm) oriented strand board Insulation: 3-1/2” (89 mm) R-11 fiberglass insula Joist: 12” (302 mm) Weyerhaeuser Trus Joist® TJ Ceiling isolation: Clark Dietrich RCSD resilient cha Ceiling: 1 layer 5/8” (16 mm) type C gypsum boa

FINISH Firm-Fill SCM-250® – I-Joist Bare Subfloor Insulation Truss Ceiling Ceiling 2 mm Vinyl Plank Isolation 3/4" (19 mm) oriented strand board

Acoustica

STC

IIC

REPORT #

-Sound 61 Rating 52

E7891.01 Report # E7891.02

58

Finish

3 mm Vinyl Tile 62STC IIC 52 E7891.03 3-1/2" 12" Clark 1 layer Bare 58 -E7891.01 Vinyl Sheet Dietrich 59 54 E7891.04 (89 mm)2 mm(302 mm) 5/8" 2 mm Vinyl 61 52 E7891.02 R-11 7 mm Sheet Vinyl RCSD (16 mm) with Rubber Backing Plank 60 57 E7891.05 fiberglass Resilient type C insulation Channel gypsum 3 mm Vinyl 62 52 E7891.03 board Tile tests were conducted with increasing compressi Note: Preceding I-Joist with 1 layer gypsum board which may affect sound performance.

2 mm Vinyl Sheet

59

54

E7891.04

7 mm 60 57 E7891.05 Sheet ® Sound System 4: FIRM-FILL SCM-250, 1” (25 mm) FIRM-FILL Brand Gypsum Concrete Vinyl with Rubber ® Subfloor Backing topping: 1” (25 mm) FIRM-FILL Brand Subfloor isolation: 1/4” (6 mm) FIRM-FILL® SCM Note: Preceding I-Joist with layer gypsum board tests were conducted with increasing compressive strength and density, Subfloor: 3/4” (19 mm) oriented strand board which may affect sound performance. Insulation: 3-1/2” (89 mm) R-11 fiberglass insula Joist: 12” (302 mm) Weyerhaeuser Trus Joist® TJ Firm-Fill SCM-250® – I-Joist 2 Ceiling isolation: Clark Dietrich RCSD resilient cha Subfloor Sound Subfloor Insulation Truss Ceiling Ceiling Ceiling: Finish2 layersSound Report # C gypsum bo 5/8” (16 mm) type Topping Mat Isolation Rating ®

1” (25 mm) FIRMFILL® Brand Gypsum Concrete

1/4" (6 mm) FIRMFILL® SCM-250 Sound Control Mat

3/4" (19 mm) oriented strand board

STC FINISH STC 3-1/2" 12" Clark 2 layers 2 mm Vinyl -(89 mm)2 mm(302 mm) 5/8" Sheet Vinyl Sheet Dietrich -R-11 RCSD (16 mm) 7 mm 7 mm Sheet Vinyl Resilient with Rubbertype Backing -- -fiberglass C Sheet insulation Channel gypsum Vinyl with 59 13 mm Engineered Wood board Rubber Backing 61 8 mm Ceramic Tile

IIC IIC 55 55 58 58

REPORT # E7891.11 E7891.11 E7891.12 E7891.12

57

E7891.13

53

E7891.14

13 mm

59

57

E7891.13

8 mm Ceramic Tile

61

53

E7891.14

UL Fire Rated Designs I-Joist L518, L530, L538,These L547, L556, L570, L589, M502, M506, ofM512 guidelines shall only beL581, a resource and are not a guarantee performance. FIRM-FILL® SCM Underlayments are only one component

acoustical performance is affected by every other component. The likelihood of achieving code compliance is contingent upon many other trad plumbers and drywall contractors. Developers and general contractors are responsible for building properly and testing field performance as soon a of the project. Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or construc a professional acoustical consultant to assure specifications are written correctly and that the floor/ceiling assembly can perform to expectations. F ensure reliability of design prior to occupancy. © 2/2016 Hacker Industries, Inc. FIRM-FILL®, GYP-SPAN® and the associated logos are the registe

13 Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-250 | © 2017

109


Sound System 4: FIRM-FILL® SCM-250, 1” (25 mm) FIRM-FILL® Brand Gypsum Concrete

SUBMITTAL FORM

Sound Mat

1” (25 mm) FIRMFILL® Brand Gypsum Concrete

1/4" (6 mm) FIRMFILL® SCM-250 Sound Control Mat

Firm-Fill® SCM-250 – I-Joist 3 FINISH STC IIC REPORT # Subfloor Insulation TrussSheet Ceiling Ceiling Finish -- Sound55 Report # 2 mm Vinyl E7891.11 Isolation RatingInc. Acousti Hacker Industries, Inc.Hacker Industries, 7 mm Sheet Vinyl with Rubber Backing --STC IIC 58 E7891.12 3/4" (19 mm) oriented strand board

Note: Preceding I-Joist tests were performance.

5962 52 57 F4543.01 E7891.13 3-1/2" 13 mm 12" Engineered PACWood 2 layers Bare (89 mm) (302 mm) 5/8" 8 mm Ceramic Tile 53 F4543.02 E7891.14 R-13 (16 mm) 2 mm Vinyl 6163 57 Plank ® ® Sound System 1: FIRM-FILL SCM-125, 3/4” (19 mm) FIRM-FILL Brand Gypsum Concret fiberglass type C insulation gypsum 3 mm Vinyl 63 56 F4543.03 board TileSubfloor topping: 3/4” (19 mm) FIRM-FILL® B Subfloor 1/8” (3 mm) FIRM-FILL® SC 2 mm Vinyl isolation: 62 57 F4543.04 Subfloor: 6” (152 mm) concrete Sheet

6” (152 mm) CONCRETE ASSEMBLY

Subfloor Topping

Subfloor topping: 1” (25 mm) FIRM-FILL® Brand Subfloor isolation: 1/4” (6 mm) FIRM-FILL® SCM Subfloor: 3/4” (19 mm) oriented strand board Insulation: 3-1/2” (89 mm) R-11 fiberglass insu Joist: 12” (302 mm) Weyerhaeuser Trus Joist® T Ceiling isolation: Clark Dietrich RCSD resilient ch Ceiling: 2 layers 5/8” (16 mm) type C gypsum b

13 mm Engineered Wood

62

F4543.05

61

These guidelines shall only be a resource and are not a guarantee of performance. FIRM-FILL® SCM Underlayments are only one componen acoustical performance is affected by every other component. The8likelihood is contingent upon many other tra mm of achieving63code compliance 61 F4543.06 plumbersFINISH and drywall contractors. Developers and general contractors are responsible for STC building properly field performance Ceramic IICand testingREPORT # as soon of the project. Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or constru Tile a professional acoustical consultant to assure specifications are written correctly and that the floor/ceiling assembly can perform to expectations. Bare of design prior to occupancy. © 2/2016 Hacker Industries, Inc. FIRM-FILL 51® --® and the associated 5014050 ensurewith reliability conducted increasing compressive strength and density, which, GYP-SPAN may affect sound logos are the regis

Bare

∆ 20*

--

UL Fire Rated Designs

7014090

13

I-Joist L518, L530, L538, L547, L556, L570, L581, L589, M502, M506, M512 Sound System 2: FIRM-FILL® SCM-250, 1” (25 mm) FIRM-FILL® Brand Gypsum Concrete

Subfloor topping: 1” (25) mm FIRM-FILL® Bra Subfloor isolation: 1/4” (6 mm) FIRM-FILL® SC Subfloor: 6” (152 mm) concrete

® SCM-250 – Concrete Assembly FINISH Firm-Fill

Subfloor Topping

Sound Mat

Subfloor

1” (25 mm) FIRMFILL® Brand Gypsum Concrete

1/4" (6 mm) FIRMFILL® SCM-250 Sound Control Mat

6" (152 mm) concrete

InsulationBareTruss Bare None

None

Ceiling Isolation None

Ceiling

None

STC Finish

IIC

REPORT #

Sound -- Report # 51 5014075 Rating -∆ 20* 7014143 STC IIC

Bare

51

--

5014075

Bare

--

Δ 20*

7014143

UL Fire Rated Designs Concrete J917, J919, J920, J924, J927, J931, J957, J991, J994 *Tested in accordance with ASTM E2179 - Standard Test Method for Laboratory Measurement of Effectiveness of Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors. 110

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-250 | © 2017


SUBMITTAL FORM Warranty Subject to express warranty stated on Hacker Industries, Inc.’s website.

Submittal Approvals Project Name

Contractor/Architect

Signature

Date

PRODUCT INFORMATION See www.HackerIndustries.com for current recommended product specifications and literature. FIRM-FILL® SCM-250, for use with Hacker Floor Underlayments, is a component in an overall floor/ceiling assembly. Its performance is affected by every other component and the likelihood of achieving code compliance is contingent upon many other trades, including framers, plumbers and drywall contractors. Developers and general contractors are responsible for building properly and testing field performance as soon as possible in order to ensure the reliability of the project. WARNING Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or construction errors that may occur. Please consult a professional acoustical consultant to ensure plans are proper and that the floor/ceiling assembly can perform to expectations.

TRADEMARKS FIRM-FILL®, GYP-SPAN®, Let Our Products Floor You™ and the associated logos are trademarks of Hacker Industries, Inc. LEED® is a registered trademark of the U.S. Green Building Council. WARRANTY HACKER INDUSTRIES, INC. SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, DIRECTLY OR INDIRECTLY SUSTAINED, NOR FOR ANY LOSS CAUSED BY APPLICATION OF THESE GOODS NOT IN ACCORDANCE WITH CURRENT PRINTED INSTRUCTION OR FOR OTHER THAN THE INTENDED USE. HACKER'S LIABILITY IS EXPRESSLY LIMITED TO REPLACEMENT OF DEFECTIVE GOODS. ANY CLAIM SHALL BE DEEMED WAIVED UNLESS MADE IN WRITING TO HACKER INDUSTRIES, INC. WITHIN 30 DAYS FROM DATE IT WAS, OR REASONABLY SHOULD HAVE BEEN, DISCOVERED. SAFETY FIRST Follow good safety/industrial hygiene practices during installation. Wear appropriate personal protective equipment. Read specs, MSDS and literature prior to specification and installation. © 2017 Hacker Industries, Inc., Newport Beach, CA.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-250 | © 2017

111


RECOMMENDED SPECIFICATIONS PART I. GENERAL 1.1

Scope

The work of this section includes FIRM-FILL® SCM-250 to be placed under FIRM-FILL® Brand Gypsum Concretes. 1.2

Qualifications

A.

FIRM-FILL® SCM-250 shall be installed by trained Licensed Applicators of Hacker Industries, Inc.

B.

All materials specified herein shall be approved by Hacker Industries, Inc., Newport Beach, CA. All others must receive prior approval.

C.

Materials shall be delivered in their original, unopened containers with identification labels intact. Protect materials from exposure to harmful weather conditions and maintain at a minimum temperature of 50˚F (10˚C).

D.

Before, during and after installation the building interior shall be ventilated and heated to a minimum of 50°F (10°C) to assure completion of the drying process for the Hacker Floor Underlayment.

PART II. PRODUCTS 2.1

Product Description

FIRM-FILL® SCM-250 is a nominal 1/4” (6 mm), random filament, corrugated “U”- groove core sound control mat designed to limit impact noise between floors. Designed for critical applications in which FIRM-FILL® Gypsum Concrete will be utilized. FIRM-FILL® SCM-250 prevents liquid moisture from passing through to the substrate, an essential quality for wood frame construction. FIRM-FILL® SCM-250 is a Class A fire-rated product. Use with a minimum 1” FIRM-FILL® Gypsum Concrete topping. 2.2

Product Limitations

A.

Shall not be used in exterior locations, below grade or where continuous exposure to moisture is likely.

B.

Shall not be used without a FIRM-FILL® Gypsum Concrete topping.

C.

Structure shall be designed so that deflection does not exceed L/360 live or dead load. Certain floor coverings such as marble, limestone, travertine and wood may have more restrictive deflection limits. Consult the appropriate floor covering manufacturer for their recommendations.

D.

Do not use mechanical fasteners to install FIRM-FILL® SCM-250, as mechanical fasteners conduct impact sound, reducing acoustical isolation.

E. FIRM-FILL® SCM-250 shall be installed with a perimeter isolation strip.

F. FIRM-FILL® SCM-250 is one component of an effective sound attenuation control system. Care must be taken in the installation of all components to ensure the ultimate design performance. Published acoustical and fire system tests were conducted under controlled laboratory or field conditions and reflect results applicable only to those specific assemblies.

112

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-250 | © 2017


RECOMMENDED SPECIFICATIONS (CONT.)

PART III. PREPARATION 3.1

Condition of Subfloor

A.

Subfloor shall be structurally sound (L/360), broom clean, dry and free from oil, grease, paraffin, laitance, wax or other contaminants. Concrete substrate shall be 28 days or older.

B.

Leak prevention: All cracks and voids should be filled with a quick-setting patching or taping compound or equal where leakage may occur.

C.

Before installation, the GC shall inspect and approve the condition of the subfloor and test the existing subfloor for moisture.

3.2

Application

A.

Scheduling

1. Installation of FIRM-FILL® SCM-250 shall not begin until other trades are finished in the area. Protect FIRM-FILL® SCM-250 from trade traffic prior to application of FIRM-FILL® Brand Gypsum Concretes.

Installation

B.

1. Perimeter Isolation Strip shall be properly installed in an “L” formation around areas where FIRM-FILL® SCM-250 will be installed, including any openings in the subfloor installation.

2. FIRM-FILL® SCM-250 is laid directly over the concrete, plywood or OSB subfloor, with the red mesh down and white/red fabric side up. It should be pushed up tightly to the isolation barrier that was previously installed around the perimeter of the floor; the gap between the floor and wall should not exceed 0.25“ (6 mm). Alternately, the FIRM-FILL® SCM-250 may be pushed up tightly to the gypsum wall board when the isolation barrier installed is FIRM-FILL® Perimeter Isolation. The gap between the floor and wall should (6 mm). not exceed 0.25” 3. FIRM-FILL® SCM-250 edge must be placed adjacent to other pieces without any gap. Rolls are manufactured with the self-adhesive selvage edge folded over on the fabric top. If necessary, tape (duct tape or 2” [51 mm]-wide tape) the 3” (76 mm) fabric overlaps snug to the fabric on the adjoining FIRM-FILL® SCM-250 strip. Tape all seams to prevent penetration into the core material during pour. Double tape seams if necessary. When unrolled, the selvage edge remains in that position. Starting at the base of the roll, smooth the selvage edge to the adjacent piece. 3.3

Application of FIRM-FILL® Brand Gypsum Concretes

A.

Taping and seams of FIRM-FILL® SCM-250 shall be checked and approved by the GC prior to the installation of FIRM-FILL® Brand Gypsum Concretes.

B.

Install FIRM-FILL® Brand Gypsum Concretes at a minimum thickness of 1”.

C.

Protection: After installation, temporary wooden planking shall be placed by GC wherever the underlayment is subject to wheeled loads.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-250 | © 2017

113


RECOMMENDED SPECIFICATIONS (CONT.)

D.

Drying: The GC shall provide continuous ventilation and adequate heat to rapidly remove moisture from the area until the underlayment is dry. If necessary, the GC shall provide mechanical ventilation and heat. Do not install finished floor coverings until the FIRMFILL® Brand Gypsum Concrete has been tested for dryness. Consult flooring contractor for recommended procedures to test for acceptable moisture levels. To avoid potential problems during the drying process, the GC shall consult Hacker Industries, Inc.’s Drying Conditions Flyer and Hacker Industries, Inc.’s website for additional information.

3.4

Preparation for Installation of Floor Coverings

A.

Sealing: Any areas where the underlayment surface has been damaged shall be cleaned and sealed. The floor covering manufacturer’s specificatiions and requirements suspersede these recommendations.

B.

Floor Covering Procedures: See Hacker Industries, Inc.’s Guidelines for Installing Finished Floor Coverings. The guideline is not a warranty and shall be used as a guideline only. See ASTM F2419.

C.

After finished floor covering is installed, trim the perimeter isolation strip below the finished flooring. Fill the groove with a bead of acoustical sealant or elastomeric sealant. Do not allow ceramic tile, grout or FIRM-FILL® Brand Gypsum Concrete to come in contact with the wall. Shim the molding above the finished floor covering and caulk with an acoustical sealant.

3.5 Field Quality Control Sound tests on underlayment systems have been conducted under laboratory and field conditions. Contact Hacker Industries, Inc. at (800) 642-3455 for information. Note: Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or construction errors that may occur. Please consult a professional acoustical consultant to ensure plans are proper and that the floor/ceiling assembly can perform to expectations.

Warranty: Hacker Industries, Inc. warrants Hacker Floor Underlayments (HFU) to be free from manufacturing defects, and when properly prepared and installed according to approved specified methods, HFU will attain minimum physical specifications as stated by Hacker Industries, Inc.’s most recent literature. Hacker Industries, Inc.’s obligation shall be limited to the replacement of the bagged product only and is subject to notice and inspection requirements. This warranty is in lieu of all other warranties, express or implied, including the warranties of merchantability and fitness for a particular purpose and all other obligations or liabilities.

114

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-250 | © 2017


Specify FIRM-FILL® SCM-400 for additional impact noise control when a thicker sound mat is needed. It helps achieve higher delta numbers than thinner mats. FIRM-FILL® SCM-400 is a cost-effective way to address Impact Insulation Class (IIC) concerns. This sound mat offers great performance in wood or concrete construction. FIRM-FILL® SCM-400 can be installed under a FIRM-FILL® Gypsum Concrete Floor Underlayment to produce an exceptional vibration isolation floor system. • An advanced solution for additional impact noise control between hard surfaces and carpeted areas • Used in wood frame construction and as a component of a well designed floor/ceiling assembly • Cost-effective way to address noise concerns and to improve IIC ratings • Minimal deflection, no creep or long term degradation • Specify with a FIRM-FILL® Gypsum Concrete Underlayment • Installed by trained Licensed Applicators


1 - FLOOR COVERING / 2 - FIRM-FILL® BRAND GYPSUM CONCRETE / 3 - FIRM-FILL® SCM-400 / 4 - PLYWOOD OR OSB / 5 - NOMINAL WOOD JOIST / 6 - BATT INSULATION / 7 - PARALLEL CHORD TRUSS / 8 - TJI ® JOIST / 9 - RESILIENT CHANNEL / 10 - GYPSUM WALLBOARD / 11 - 6” CONCRETE

Improves Impact Improves Sound Allows vapor pass- Class A fire-rated Performance in Installed only by Insulation Class Transmission Class through to prevent wood-frame and product Hacker Industries’ 6 - BATT INSULATION PARALLEL CHORD TRUSS (STC) / 8 - TJI ®ratings JOIST / 9 - RESILIENT CHANNEL / 10 - GYPSUM WALLBOARD / 11 - 6” CONCRETE structures / 7 -(IIC) ratings trapped moisture concrete Licensed Applicators

5000

3150

2000

1250

800

40

FIRM-FILL® SCM-400 IC Contour

0

5000

3150

2000

1250

800

Robinson Wheel

500

310

200

125

80

Must be used with 50

4000

2500

1600

1000

630

400

250

L/360 Deflection must Do not use mechnot exceed L/360 anical fasteners Deflection must Do not use live or all dead load with Install FIRM-FILL® Tape seams not exceed L/360 Mechanical duct tape or 2” wide Brand Gypsum live or dead load Concrete Fasteners cellophane tape

500

50

10

moisture

® Brand FIRM-FILL tested Extraby Heavy Class A Fire-rated Installed Frequency (Hz) Gypsum Concrete Hacker Duty Industries Product trained Licensed Applicators

Must be used with FIRM-FILL® Brand Must be used Gypsum Concrete Apply Hacker ® with FIRM-FILL TopCoat™ SP if Gypsum Concrete specified

Robinson Wheel tested Extra Heavy Robinson Wheel Duty Install finished floor tested Extra covering only when Heavy Duty completely dry

© 09/2014 Hacker Industries, Inc. FIRM-FILL® and the associated logos are trademarks of Hacker Industries, Inc., Newport Beach, CA.

Install FIRM-FILL® SCM-400 mat with blue mesh down

Install isolation barrier around perimeter of floor

116

60

20

STC 52 Reference Contour

0

160

Install isolation barrier around perimeter of floor

Frequency (Hz)

30

FIRM-FILL® SCM-400

310

10

200

40

20

125

70

50

STC +

80

80

60

30

®

100

70

100

enclosed before installation)

30

90

structures

May not be used as a vapor barrier May not be used Install FIRM-FILL® as a vapor SCM-400 matbarrier with blue mesh down

40

80

Beginning Deflection Residual Requires dry-in May not be used Deflection must Do not use mechThickness During Load Thickness (building must be asImproves a vapor barrier exceed L/360 anical Performance Impact not Improves Sound Allows vapor to Frequency (Hz) fasteners fullyin enclosed or dead load wood-frame Insulation Class liveTransmission pass through to before installation) and concrete (IIC) ratings Class (STC) ratings prevent trapped

Requires dry-in (building must be Requires dryfully enclosed Install isolation in (building before barrierinstallation) around mustofbefloor fully perimeter

50

FIRM-FILL SCM-400 Class20 A fire-rated Installed only by IC Contour 10 product Hacker Industries’ 0 Licensed Applicators

Frequency (Hz)

90

60

50

0

4000

IIC +

2500

42 lb/ft² 105 lb/ft² 505 lb/ft²

Allows vapor passSTC 52 Reference Contour through to prevent trapped moisture 1600

20 Improves Sound 10 Transmission Class (STC) 0ratings

1000

0.3

FIRM-FILL® SCM-400

630

Compression Resistance

30

400

0.4

0.1

40

Thickness

0.5

0.2

70

50

250

During Load

80

60

160

Thickness

Improves Impact Insulation Class (IIC) ratings Deflection Residual

90

70

100

in Performance 0.1 wood-frame and structures concrete 0 Beginning

© 2017 Hacker Industries, Inc. FIRM-FILL® and the associated logos are trademarks of Hacker Industries, Inc., Newport Beach, CA.

42 lb/ft² 105 lb/ft² 505 lb/ft²

0.2

100

80

Ln (dB)

0.3

90

Ln (dB)

0.4

Sound Transmission Loss (dB)

0.5

Sound Transmission Loss (dB)

Compression Resistance

1 - FLOOR COVERING / 2 - FIRM-FILL® BRAND GYPSUM CONCRETE / 3 - FIRM-FILL® SCM-400 / 4 - PLYWOOD OR OSB / 5 - NOMINAL WOOD JOIST / 6 - BATT INSULATION / 7 - PARALLEL CHORD TRUSS / ® BRAND ® 1 -® FLOOR / 2 - FIRM-FILL GYPSUM CONCRETE 8 - TJI JOIST / 9 COVERING - RESILIENT CHANNEL / 10 - GYPSUM WALLBOARD / 11 - 6” CONCRETE / 3 - FIRM-FILL SCM -400 / 4 - PLYWOOD OR OSB / 5 - NOMINAL WOOD JOIST

Install FIRM-FILL® SCM-400 mat with purple mesh down

Tape all seams with duct tape or 2” wide cellophane tape

Tape all seams with duct tape or 2” wide tape

Install FIRM-FILL® Brand Gypsum Concrete

Apply Hacker TopCoat™ SP if specified

Install finished floor covering only when completely dry

Install FIRM-FILL® Apply Hacker Install finished © 09/2014 Industries, Inc. ® SP Brand Gypsum TopCoat floorHacker covering FIRM-FILL and the associated logos are trademarks of Hacker Industries, Inc., Newport Beach, CA. Concrete when specified only when completely dry ®

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-400 | © 2017


SUBMITTAL FORM TECHNICAL DATA Roll Weight Thickness

PROPERTIES 39 lb (17.7 kg) 3/8 in (10 mm) nominal

Width Core Color Packaging Length Total Square Feet Effectiveness of Reducing IIC Sound Steiner Tunnel Test

60 in (152.4 cm) Purple 80 ft (24.5 m) 400 ft² (37.16 m²) ΔIIC 20.0` Class A

Benefits • • • • • •

Provides additional impact noise control when a thicker sound mat is specified Cost-effective way to address Impact Insulation Class (IIC) concerns Minimal deflection, no creep or long term degradation Excellent performance in wood frame construction and concrete structures Helps to achieve higher delta IIC numbers Installed only by trained Licensed Applicators across North America

Product Description FIRM-FILL® SCM-400 is a nominal 3/8” (10 mm), entangled polymeric filament sound control mat designed to limit impact noise between floors. Designed for critical applications in which FIRM-FILL® Gypsum Concrete will be utilized. Use in conjunction with a minimum 1-1/4” FIRM-FILL® Gypsum Concrete topping.

Limitations • Shall not be used in exterior locations, below grade or where continuous exposure to moisture is likely. • Shall not be used without a FIRM-FILL® Gypsum Concrete topping. • Structure shall be designed so that deflection does not exceed L/360 live or dead load. Certain floor coverings, such as marble, limestone, travertine and wood, may have more restrictive deflection limits. Consult the appropriate floor covering manufacturer for their recommendations. • Do not use mechanical fasteners to install FIRM-FILL® SCM-400, as mechanical fasteners conduct impact sound, reducing acoustical isolation. • FIRM-FILL® SCM-400 shall be installed with a perimeter isolation strip. • FIRM-FILL® SCM-400 is one component of an effective sound attenuation control system. Care must be taken in the installation of all components to ensure the ultimate design performance. Published acoustical and fire system tests were conducted under controlled laboratory and/or field conditions and reflected results are applicable only to those specific assemblies.

Installation Before, during and after installation, the building must be enclosed and the temperature maintained at a minimum of 50°F (10°C). Prior to installation, the subfloor shall be structurally sound (L/360), broom cleaned, dry and free from oil, grease, paraffin, laitance, wax or other contaminants.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-400 | © 2017

117


SUBMITTAL FORM INSTALLATION(cont.) Attach perimeter isolation strip or approved alternative to the walls, conduit, flanges, ballasts, etc. in order to isolate or break the vibration transmission path between the floor and wall. Reinforcement is recommended in doorways and other high traffic or transition areas. FIRM-FILL® SCM-400 is laid directly over the concrete, plywood or OSB subfloor, with the purple mesh down and white/purple fabric side up. It should be pushed up tightly to the isolation barrier. Alternately, the FIRMFILL® SCM-400 may be pushed up tightly to the gypsum wall board when the isolation barrier installed is FIRMFILL® Perimeter Isolation. The gap between the floor and wall shall not exceed 0.25” (6 mm). FIRM-FILL® SCM-400 edge must be placed adjacent to other pieces without any gap. Rolls are manufactured with the self-adhesive selvage edge folded over on the fabric top. When unrolled, the selvage edge remains in position. Starting at the base of the roll, smooth the selvage edge to the adjacent piece. If necessary, tape (duct tape or 2” [51 mm]-wide tape) the 3” (76 mm) fabric overlaps snug to the fabric on the adjoining FIRMFILL® SCM-400 strip. Tape all seams to prevent penetration into the core material during pour. Double tape seams if necessary. Finished floor coverings can be installed when the FIRM-FILL® Gypsum Concrete is completely dry. Consult flooring contractor for acceptable levels of moisture and recommended procedures to test for dryness. Reference Hacker Industries, Inc.’s Guidelines for Installing Finished Floor Coverings. This guideline is not a warranty and shall be used as a guideline only. See ASTM F2419.

Product Data Core Thickness: Roll Weight: Packaging Length: Core Width: Total square feet:

3/8 in (10 mm) nominal 39 lb (17.7 kg) 80 ft (24.5 m) 60 in (149 cm) 400 ft² (37.16 m²)

Sound Test & UL Fire Rated Designs PURPOSE STATEMENT/DISCLAIMER These guidelines are designed to provide the architectural and building communities with detailed performance data on Hacker Industries, Inc.’s comprehensive portfolio of sound attenuation tests and UL Fire Rated Designs. The tests for the assemblies included in these guidelines were conducted in a laboratory setting per ASTM C177, E84, E90, E492 and E2179. These guidelines are not warranties and should be used as guidelines only. The architects’ and general contractors’ recommendations supersede these guidelines. Field performance may vary. Subject to express Warranty stated on Hacker Industries, Inc.’s website. Hacker Industries, Inc. regularly performs acoustical and fire (UL) testing to ensure performance standards for our products. Firm Fill® SCM (sound control mats), including Firm Fill® SCM-400, were tested acoustically with the following floor assemblies and performed as noted.

118

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-400 | © 2017


Hacker Industries, Inc.

SUBMITTAL FORM

Acousti

OPEN WEB

Sound System 5: FIRM-FILL® SCM-400, 1-1/4” (32 mm) FIRM-FILL® Brand Gypsum Conc

Subfloor topping: 1-1/4” (32 mm) FIRM-FILL Subfloor isolation: 3/8” (10 mm) FIRM-FILL® Subfloor: 3/4” (19 mm) oriented strand board Insulation: 3-1/2” (89 mm) unfaced R-13 fibe Truss: 18” (457 mm) L/360 open web truss Ceiling isolation: Clark Dietrich RCSD resilient Ceiling: 5/8” (16 mm) type C gypsum board FINISH

Subfloor Topping

Sound Mat

1-1/4” (32 mm) FIRMFILL® Brand Gypsum Concrete

3/8" (10 mm) FIRMFILL® SCM-400 Sound Control Mat

STC

Firm-Fill Bare ® SCM-400 – Open Web Subfloor Insulation 2 mm Truss Ceiling Ceiling Vinyl Plank Isolation 3 mm Vinyl Tile 3/4" (19 mm) oriented strand board

3-1/2" (89 mm) unfaced R-13 fiberglass insulation

Finish

218" mm Vinyl Sheet Clark 5/8" Bare (457 mm) Dietrich (16 mm) 2 mm Vinyl 7L/360 mm Sheet Vinyl RCSDwith Rubber type C Backing Plank open Resilient gypsum 13 mm Engineered Wood web truss Channel board 3 mm Vinyl Tile 8 mm Ceramic Tile 2 mm Vinyl Sheet

IIC

REPORT #

61 50 D6435.15 Sound 53 Report # 62 D6435.16 Rating 62 IIC 54 D6435.17 STC 62 61

D6435.18 50 53 D6435.15

62 61

53 58 D6435.16 D6435.19

61 62 61 62

D6435.20 D6435.17 -D6435.21 53 D6435.18 54

58

7 mm Sheet 61 58 D6435.19 Vinyl with Sound System 6: Hacker Sound Mat I,Rubber 1” (25 mm) FIRM-FILL® Brand Gypsum Concrete Backing Subfloor topping: 1” (25 mm) FIRM-FILL® Bra 13 mm 61 58 D6435.20 Subfloor isolation: .08” (2 mm) Hacker Sound Engineered Subfloor: 3/4” (19 mm) oriented strand board Wood Insulation: 61 3-1/2”--(89 mm) unfaced R-13 fibe 8 mm D6435.21 Truss: 18” (457 mm) L/360 open web truss Ceramic Tile Ceiling isolation: Clark Dietrich RCSD resilient Ceiling: 5/8” (16 mm) type C gypsum board UL Fire Rated Designs

Contributes points to LEED® certification Open Web L521, L528, L529, L534, L542, L546, L550, L558, L563, L574, L576, L577, L579, L583, L585, L592, M500, M503, M508 FINISH STC IIC REPORT # 7 mm Laminate

63

53

C7016.01

3 mm LVT

63

50

C8706.05

3 mm LVT over Hacker Sound Mat I

63

52

C8706.02

3 mm LVT over 5 mm Ecore QT4005

63

53

C8706.03

3 mm LVT over 10 mm Ecore QT4010

63

53

C8706.04

These guidelines shall only be a resource and are not a guarantee of performance. FIRM-FILL® SCM Underlayments are only one compo acoustical performance is affected by every other component. The likelihood of achieving code compliance is contingent upon many othe plumbers and drywall contractors. Developers and general contractors are responsible for building properly and testing field performance as s of the project. Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or con a professional acoustical consultant to assure specifications are written correctly and that the floor/ceiling assembly can perform to expectatio ensure reliability of design prior to occupancy. © 2/2016 Hacker Industries, Inc. FIRM-FILL®, GYP-SPAN® and the associated logos are the

7 Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-400 | © 2017

119


Hacker Industries, Inc.

Sound System 4: FIRM-FILL® SCM-400, 1-1/4” (32 mm) FIRM-FILL® Brand Gypsum Con

NOMINAL WOOD

SUBMITTAL FORM

Acoust

Subfloor topping: 1-1/4” (32 mm) FIRM-FIL Subfloor isolation: 3/8” (10 mm) FIRM-FILL® Subfloor: 3/4” (19 mm) oriented strand boar Insulation: 3-1/2” (89 mm) R-13 fiberglass in Joist: 9-1/4” (235 mm) 2x10 dimensional lum Ceiling isolation: Clark Dietrich RCSD resilien Ceiling: 5/8” (16 mm) type C gypsum board FINISH ® Firm-Fill BareSCM-400 – Nominal Wood

Subfloor Topping

Sound Mat

Subfloor Insulation

Truss Ceiling 2 mm Vinyl Plank Isolation

Ceiling

STC Finish

3 mm Vinyl Tile 1-1/4” (32 mm) FIRMFILL® Brand Gypsum Concrete

3/8" (10 mm) FIRMFILL® SCM-400 Sound Control Mat

3/4" (19 mm) oriented strand board

3-1/2" (89 mm) R-13 fiberglass insulation

Clark 5/8" Bare 29-1/4" mm Vinyl Sheet (235 mm) Dietrich (16 mm) 2 mm Vinyl 72x10 mm SheetRCSD Vinyl with Rubber type C Backing Plank Resilient gypsum 13 mm Engineered Wood Channel board 3 mm Vinyl Tile 8 mm Ceramic Tile 2 mm Vinyl Sheet

IIC

REPORT #

59 -E3147.01 Sound Report # 61 52 E3147.02 Rating 61 IIC 53 E3147.03 STC 59 60 61 59

-- 53 E3147.01 E3147.04 52 58 E3147.02 E3147.05

59 61 59 60

E3147.06 53 57 E3147.03 51 E3147.07 53 E3147.04

7 mm Sheet Vinyl with Rubber Backing

59

58

E3147.05

13 mm Engineered Wood

59

57

E3147.06

8 mm Ceramic Tile

59

51

E3147.07

UL Fire Rated Designs Nominal Wood L006, L201, L202, L206, L208, L209, L210, L211, L212, L501, L502, L503, L504, L505, L506, L507, L508, L509, L510, L511, L512, L513, L514, L515, L516, L517, L519, L520, L522, L523, L525, L526, L532, L533, L535 , L536, L537, L540, L541, L545, L557, L569, L588, L590, L593, L598, M504, M517, M519, M530, M531, M517

These guidelines shall only be a resource and are not a guarantee of performance. FIRM-FILL® SCM Underlayments are only one comp acoustical performance is affected by every other component. The likelihood of achieving code compliance is contingent upon many oth plumbers and drywall contractors. Developers and general contractors are responsible for building properly and testing field performance as of the project. Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or co a professional acoustical consultant to assure specifications are written correctly and that the floor/ceiling assembly can perform to expecta ensure reliability of design prior to occupancy. © 2/2016 Hacker Industries, Inc. FIRM-FILL®, GYP-SPAN® and the associated logos are the

10 120

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-400 | © 2017


Hacker Industries, Inc.

I-JOIST

SUBMITTAL FORM

Subfloor Topping 1-1/4” (32 mm) FIRMFILL® 3310 Gypsum Concrete

Sound Mat 3/8" (10 mm) FIRMFILL® SCM-400 Sound Control Mat

Sound System 6: FIRM-FILL® SCM-400, 1-1/4” (32 mm) FIRM-FILL® 3310 Gypsum Concret

Subfloor topping: 1-1/4” (32 mm) FIRM-FILL® 3 Subfloor isolation: 3/8” (10 mm) FIRM-FILL® SC Subfloor: 3/4” (19 mm) oriented strand board Insulation: 3-1/2” (89 mm) R-11 fiberglass insu Joist: 12” (302 mm) Weyerhaeuser Trus Joist® T Ceiling isolation: Clark Dietrich RCSD resilient c Ceiling: 2 layers 5/8” (16 mm) type C gypsum b

FINISH Firm-Fill® SCM-400 – I-Joist Bare Subfloor Insulation Truss Ceiling Ceiling 2 mm Vinyl PlankIsolation 3/4" (19 mm) oriented strand board

Acoustic

STC Finish

3 mm Vinyl Tile 3-1/2" 2 mm 12"Vinyl Sheet Clark 2 layers Bare (89 mm) (302 mm) Dietrich 5/8" R-11 RCSD (16Backing mm) 2 mm Vinyl 7 mm Sheet Vinyl with Rubber Plank fiberglass Resilient type C insulation13 mm Engineered Channel Wood¹ gypsum 3 mm Vinyl board Tile 13 mm Engineered Wood 2 mm Vinyl Sheet 8 mm Ceramic Tile

IIC

REPORT #

51 Sound 62Rating54

E7892.08 Report # E7892.09

STC 62 6161

IIC 58 51 54 54 58

E7892.10 E7892.08 E7892.11 E7892.09 E7892.12

6262

54 58

E7892.06 E7892.10

--

60 54 55

E7892.13 E7892.11 E7892.14

61

62 61

61 61

7 mmCeiling: Sheet 1 layer 61 5/8” 58(16 E7892.12 ¹ Assembly differs from above in the following: mm) type C gypsum boa Vinyl with Note: Preceding I-Joist with 1 layer gypsumRubber board tests were conducted with increasing compres which may affect sound performance. Backing

® 13 (25 mmmm) FIRM-FILL 62 54 E7892.06 Sound System 7: Hacker Sound Mat II, 1” Brand Gypsum Concrete Engineered Wood¹ Subfloor topping: 1” (25 mm) FIRM-FILL® Bran 13Subfloor mm isolation: -- 1/4” 60 (6E7892.13 mm) Hacker Sound M Engineered Subfloor: 5/8” (16 mm) plywood & 1 layer 1/2” Wood Insulation: 3-1/2” (89 mm) fiberglass insulation 8 Joist: mm 10” I-Joist 61 55 E7892.14 Ceramic Ceiling Tile isolation: Unimast RC Deluxe resilient fu ¹Assembly differs from above in the following: Ceiling: 1 layer 5/8” (16 mm) type C gypsum board Ceiling: 2 layers 5/8” (16 mm) type C gypsum b Note: Preceding I-Joist with 1 layer gypsum board tests were conducted with increasing compressive strength and density, which may affect sound performance. Contributes points to LEED® certification

UL Fire Rated Designs I-Joist L518, L530, L538, L547, L556, L570, L581, L589, M502, M506, M512 FINISH

Reinforcing is required for gypsum concrete over Hacker Sound Mat II. STC

IIC

REPORT #

2 mm Vinyl Sheet

--

53

7003005

2 mm Vinyl Sheet over Hacker Sound Mat II

--

56

7003006

Note: Reinforcing is required for gypsum concrete thicknesses under 1-1/4” over Hacker Sound M

These guidelines shall only be a resource and are not a guarantee of performance. FIRM-FILL® SCM Underlayments are only one compone acoustical performance is affected by every other component. The likelihood of achieving code compliance is contingent upon many other tr plumbers and drywall contractors. Developers and general contractors are responsible for building properly and testing field performance as soo of the project. Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or constr a professional acoustical consultant to assure specifications are written correctly and that the floor/ceiling assembly can perform to expectations ensure reliability of design prior to occupancy. © 2/2016 Hacker Industries, Inc. FIRM-FILL®, GYP-SPAN® and the associated logos are the reg

15 Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-400 | © 2017

121


Subfloor Topping

Sound Mat

1-1/4” (32 mm) FIRMFILL® Brand Gypsum Concrete

3/8" (10 mm) FIRMFILL® SCM-400 Sound Control Mat

Subfloor

6” (152 mm) CONCRETE ASSEMBLY

SUBMITTAL FORM

Sound System 3: FIRM-FILL® SCM-400, 1-1/4” (32 mm) FIRM-FILL® Brand Gypsum Conc

Subfloor topping: 1-1/4” (32 mm) FIRM-FILL Subfloor isolation: 3/8” (10 mm) FIRM-FILL® Subfloor: 6” (152 mm) concrete

® SCM-400 – Concrete Assembly Firm-FillFINISH

Insulation BareTruss Bare

6" None (152 mm) concrete

Sheet NoneVinyl Bare

Ceiling Isolation None

Ceiling

None

STC Finish

Bare Bare

IIC

REPORT #

Sound -- Report # 52 5014051 Rating -50 7014063 STC IIC -7014064 52 -- 50 5014051 --

7014091 50 ∆ 23* 7014063

Sheet Vinyl -50 7014064 *Tested in accordance with ASTM E2179 – Standard Test Method for Laboratory Mea Bare -Δ 7014091 Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors. 23*

*Tested in accordance with ASTM E2179 - Standard Test Method for Laboratory Measurement of Effectiveness ®of Floor Sound SystemConcrete 4: Hacker Sound Mat I, 3/4” (19 mm) FIRM-FILL Brand Gypsum Concret Coverings in Reducing Impact Sound Transmission Through Floors. UL Fire Rated Designs Concrete J917, J919, J920, J924, J927, J931, J957, J991, J994

Subfloor topping: 3/4” (19 mm) FIRM-FILL® B Subfloor isolation: .08” (2 mm) Hacker Sound Subfloor: 6” (152 mm) concrete

*Tested in accordance with ASTM E2179 - Standard Test Method for Laboratory Measurement of Effectiveness of Floor Coveringspoints in Reducing Contributes to LEED® certification Impact Sound Transmission Through Concrete Floors.

Warranty

FINISH

Bare Subject to express warranty stated on Hacker Industries, Inc.’s website. Bare

Submittal Approvals

STC

IIC

53 -Project Name

--

∆ 15*

REPORT # 5014076 7014144

Contractor/Architect

*Tested in accordance with ASTM E2179 – Standard Test Method for Laboratory Mea Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors. Signature Date

PRODUCT INFORMATION See www.HackerIndustries.com for current recommended product specifications and literature.

TRADEMARKS FIRM-FILL®, GYP-SPAN®, Let Our Products Floor You™ and the associated logos are trademarks of Hacker Industries, Inc. LEED® is a registered trademark of the U.S. Green Building Council.

FIRM-FILL® SCM-400, for use with Hacker Floor Underlayments, is a component in an overall floor/ceiling assembly. Its performance is WARRANTY affected by every other component and the likelihood of achieving code HACKER INDUSTRIES, INC. SHALL NOT BE LIABLE FOR INCIDENTAL compliance is contingent upon many other trades, including framers, OR CONSEQUENTIAL DAMAGES, DIRECTLY OR INDIRECTLY plumbers and drywall contractors. Developers and general contractors SUSTAINED, NOR FOR ANY LOSS CAUSED BY APPLICATION OF ® These guidelines be a resource and are notIN a guarantee of performance. SCM Underlayments are only one compo are responsible for building properly and testing field performance as shall only THESE GOODS NOT ACCORDANCE WITH FIRM-FILL CURRENT PRINTED acoustical performance is affected by every other component. The likelihood of achieving code is contingent upon many othe soon as possible in order to ensure the reliability of the project. INSTRUCTION OR FOR OTHER THAN THE INTENDED compliance USE. HACKER'S plumbers and drywall contractors. Developers and general contractors areTO responsible for building OF properly and testing field performance as s LIABILITY IS EXPRESSLY LIMITED REPLACEMENT DEFECTIVE of the project. Laboratory tests are not aANY guarantee of field performance because ofWAIVED the issues UNLESS noted aboveMADE and many other design and/or con WARNING GOODS. CLAIM SHALL BE DEEMED a professional acoustical consultant to assure specifications are written correctly and that the floor/ceiling assembly can perform to expectati Laboratory tests are not a guarantee of field performance because of the IN WRITING TO HACKER INDUSTRIES, INC. WITHIN 30 DAYS FROM ensure reliability of design prior to occupancy. © 2/2016 Hacker Industries, Inc. FIRM-FILL®, GYP-SPAN® and the associated logos are the issues noted above and many other design and/or construction errors DATE IT WAS, OR REASONABLY SHOULD HAVE BEEN, DISCOVERED. that may occur. Please consult a professional acoustical consultant to ensure plans are proper and that the floor/ceiling assembly can perform SAFETY FIRST to expectations. Follow good safety/industrial hygiene practices 17during installation. Wear appropriate personal protective equipment. Read specs, MSDS and literature prior to specification and installation. © 2017 Hacker Industries, Inc., Newport Beach, CA.

122

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-400 | © 2017


RECOMMENDED SPECIFICATIONS PART I. GENERAL 1.1

Scope

The work of this section includes FIRM-FILL® SCM-400 to be placed under FIRM-FILL® Brand Gypsum Concretes. 1.2

Qualifications

A. FIRM-FILL® SCM-400 shall be installed by trained Licensed Applicators of Hacker Industries, Inc.

B.

All materials specified herein shall be approved by Hacker Industries, Inc., Newport Beach, CA. All others must receive prior approval.

C.

Materials shall be delivered in their original, unopened containers with identification labels intact. Protect materials from exposure to harmful weather conditions and maintain at a minimum temperature of 50˚F (10˚C).

D.

Before, during and after installation the building interior shall be ventilated and heated to a minimum of 50°F (10°C) to assure completion of the drying process for the Hacker Floor Underlayment.

PART II. PRODUCTS 2.1

Product Description

FIRM-FILL® SCM-400 is a nominal 3/8” (10 mm), entangled polymeric filament sound control mat designed to limit impact noise between floors. Designed for critical applications in which FIRM-FILL® Brand Gypsum Concrete will be utilized. Use in conjuction with a minimum 1-1/4” FIRM-FILL® Brand Gypsum Concrete topping. 2.2 Product Limitations

A.

Shall not be used in exterior locations, below grade or where continuous exposure to moisture is likely.

B.

Shall not be used without a FIRM-FILL® Gypsum Concrete topping.

C.

Structure shall be designed so that deflection does not exceed L/360 live or dead load. Certain floor coverings such as marble, limestone, travertine and wood may have more restrictive deflection limits. Consult the appropriate floor covering manufacturer for their recommendations.

D.

Do not use mechanical fasteners to install FIRM-FILL® SCM-400, as mechanical fasteners conduct impact sound, reducing acoustical isolation.

E. FIRM-FILL® SCM-400 shall be installed with a perimeter isolation strip.

F.

FIRM-FILL® SCM-400 is one component of an effective sound attenuation control system. Care must be taken in the installation of all components to ensure the ultimate design performance. Published acoustical and fire system tests were conducted under controlled laboratory or field conditions and reflect results applicable only to those specific assemblies.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-400 | © 2017

123


RECOMMENDED SPECIFICATIONS (CONT.)

PART III. PREPARATION 3.1

Condition of Subfloor

A.

Subfloor shall be structurally sound (L/360), broom clean, dry and free from oil, grease, paraffin, laitance, wax or other contaminants. Concrete substrate shall be 28 days or older.

B.

Leak prevention: All cracks and voids should be filled with a quick-setting patching or taping compound or equal where leakage may occur.

C.

Before installation, the GC shall inspect and approve the condition of the subfloor and test the existing subfloor for moisture.

3.2

Application

A.

Scheduling

1. Installation of FIRM-FILL® SCM-400 shall not begin until other trades are finished in the area. Protect FIRM-FILL® SCM-400 from trade traffic prior to application of FIRM-FILL® Brand Gypsum Concretes.

Installation

B.

1. Perimeter Isolation Strip shall be properly installed in an “L” formation around areas where FIRM-FILL® SCM-400 will be installed, including any openings in the subfloor installation.

2. FIRM-FILL® SCM-400 is laid directly over the concrete, plywood or OSB subfloor, with the purple mesh down and white/purple fabric side up. It should be pushed up tightly to the isolation barrier that was previously installed around the perimeter of the floor; the gap between the floor and wall should not exceed 0.25“ (6 mm). Alternately, the FIRM-FILL® SCM-400 may be pushed up tightly to the gypsum wall board when the isolation barrier installed is FIRM-FILL® Perimeter Isolation. The gap between the floor and wall should not exceed 0.25” (6 mm). 3. FIRM-FILL® SCM-400 edge must be placed adjacent to other pieces without any gap. Rolls are manufactured with the self-adhesive selvage edge folded over on the fabric top. If necessary, tape (duct tape or 2” [51 mm]-wide tape) the 3” (76 mm) fabric overlaps snug to the fabric on the adjoining FIRM-FILL® SCM-400 strip. Tape all seams to prevent penetration into the core material during pour. Double tape seams if necessary. When unrolled, the selvage edge remains in that position. Starting at the base of the roll, smooth the selvage edge to the adjacent piece. 3.3

Application of FIRM-FILL® Brand Gypsum Concretes

A.

Taping and seams of FIRM-FILL® SCM-400 shall be checked and approved by the GC prior to the installation of FIRM-FILL® Brand Gypsum Concretes.

B.

Install FIRM-FILL® Gypsum Concretes at a minimum thickness of 1-1/4”.

C.

Protection: After installation, temporary wooden planking shall be placed by GC wherever the underlayment is subject to wheeled loads.

124

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-400 | © 2017


RECOMMENDED SPECIFICATIONS (CONT.)

D.

Drying: The GC shall provide continuous ventilation and adequate heat to rapidly remove moisture from the area until the underlayment is dry. If necessary, the GC shall provide mechanical ventilation and heat. Do not install finished floor coverings until the FIRM-FILL® Gypsum Concrete has been tested for dryness. Consult flooring contractor for recommended procedures to test for acceptable moisture levels. To avoid potential problems during the drying process, the GC shall consult Hacker Industries, Inc.’s Drying Conditions Flyer and Hacker Industries, Inc.’s website for additional information.

3.4

Preparation for Installation of Floor Coverings

A.

Sealing: Any areas where the underlayment surface has been damaged shall be cleaned and sealed. The floor covering manufacturer’s specificatiions and requirements suspersede these recommendations.

B.

Floor Covering Procedures: See Hacker Industries, Inc.’s Guidelines for Installing Finished Floor Coverings. The guideline is not a warranty and shall be used as a guideline only. See ASTM F2419.

C.

After finished floor covering is installed, trim the perimeter isolation strip below the finished flooring. Fill the groove with a bead of acoustical sealant or elastomeric sealant. Do not allow ceramic tile, grout or FIRM-FILL® Gypsum Concrete to come in contact with the wall. Shim the molding above the finished floor covering and caulk with an acoustical sealant.

3.5

Field Quality Control

Sound tests on underlayment systems have been conducted under laboratory and field conditions. Contact Hacker Industries, Inc. at (800) 642-3455 for information. Note: Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or construction errors that may occur. Please consult a professional acoustical consultant to ensure plans are proper and that the floor/ceiling assembly can perform to expectations.

Warranty: Hacker Industries, Inc. warrants Hacker Floor Underlayments (HFU) to be free from manufacturing defects, and when properly prepared and installed according to approved specified methods, HFU will attain minimum physical specifications as stated by Hacker Industries, Inc.’s most recent literature. Hacker Industries, Inc.’s obligation shall be limited to the replacement of the bagged product only and is subject to notice and inspection requirements. This warranty is in lieu of all other warranties, express or implied, including the warranties of merchantability and fitness for a particular purpose and all other obligations or liabilities.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-400 | © 2017

125


Specify FIRM-FILL® SCM-750 for maximum noise control when a thicker sound mat is needed. This sound mat delivers more sound delta numbers than thinner mats. FIRM-FILL® SCM-750 is designed for performance in the most challenging sound control conditions. FIRM-FILL® SCM-750 may be installed under a FIRM-FILL® Gypsum Concrete Floor Underlayment to produce an exceptional vibration isolation floor system. • Creates the largest air void for Impact Insulation Class (IIC) concerns • Delivers more sound delta numbers than thinner mats • Performance in wood frame construction and concrete structures • Minimal deflection, no creep or long term degradation • Lightweight and easy to install • Ideal solution in open beam construction • Installed by trained Licensed Applicators


1 - FLOOR COVERING / 2 - FIRM-FILL® BRAND GYPSUM CONCRETE / 3 - FIRM-FILL® SCM-750 / 4 - PLYWOOD OR OSB / 5 - NOMINAL WOOD JOIST / 6 - BATT INSULATION / 7 - PARALLEL CHORD TRUSS / ® BRAND ® 1 -® FLOOR / 2 - FIRM-FILL GYPSUM CONCRETE 8 - TJI JOIST / 9 COVERING - RESILIENT CHANNEL / 10 - GYPSUM WALLBOARD / 11 - 6” CONCRETE / 3 - FIRM-FILL SCM -750 / 4 - PLYWOOD OR OSB / 5 - NOMINAL WOOD JOIST

6 - BATT INSULATION / 7 - PARALLEL CHORD TRUSS / 8 - TJI ® JOIST / 9 - RESILIENT CHANNEL / 10 - GYPSUM WALLBOARD / 11 - 6” CONCRETE

© 2017 Hacker Industries, Inc. FIRM-FILL® and the associated logos are trademarks of Hacker Industries, Inc., Newport Beach, CA.

Performance in wood-frame and concrete structures

Performance in wood-frame and concrete structures

IIC + Improves Impact Insulation Class (IIC) ratings

Improves Impact Insulation Class (IIC) ratings

STC + Improves Sound

Transmission Class (STC) ratings

Improves Sound Transmission Class (STC) ratings

Allows vapor passthrough to prevent trapped moisture

Class A fire-rated product

Installed only by Hacker Industries’ Licensed Applicators

Allows vapor to pass through to prevent trapped moisture

Class A Fire-rated Product

Installed by Hacker Industries trained Licensed Applicators

Do not use Mechanical Fasteners

Must be used with FIRM-FILL® Gypsum Concrete

Robinson Wheel tested Extra Heavy Duty

Must be used with FIRM-FILL® Brand Gypsum Concrete

Robinson Wheel tested Extra Heavy Duty

Apply Hacker TopCoat™ SP when specified

Install finished floor covering only when completely dry

L/360

Requires dryin (building must be fully enclosed before installation)

Requires dry-in (building must be fully enclosed before installation)

Install isolation barrier around perimeter of floor

May not be used as a vapor barrier

May not be used as a vapor barrier

Install FIRM-FILL® SCM-750 mat with green mesh down

Deflection must not exceed L/360 live or dead load

Deflection must not exceed L/360 live or dead load

Tape all seams with duct tape or 2” wide tape

Do not use mechanical fasteners

Install FIRM-FILL® Gypsum Concrete

Install isolation Install FIRM-FILL® Tape all seams with Install FIRM-FILL® barrier around SCM-750 mat with tape or 2”SCM-750 wide Brand Gypsum Hacker Industries, Inc. | Architect Binderduct | Firm-Fill® | © 2017 perimeter of floor blue mesh down cellophane tape Concrete

Apply Hacker TopCoat™ SP if specified

Install finished floor covering only when 127 completely dry


SUBMITTAL FORM TECHNICAL DATA Roll Weight Thickness

PROPERTIES 39 lb (17.6 kg) 3/4 in (19 mm) nominal

Width Core Color Packaging Length Total Square Feet

60 in (152.4 cm) Green 80 ft (24.5 m) 400 ft² (37.16 m²)

Benefits • • • • • • • •

Excellent performance at reducing sound in mid and high frequencies Creates the largest air void of any sound control mat Additional impact sound deadening when a thicker sound mat is specified Extra resiliency for greater sound absortion Cost-effective way to address Impact Insulation Class (IIC) concerns Minimal deflection, no creep or long term degradation Increases STC ratings over bare wood frame construction and IIC levels over concrete Installed only by trained Licensed Applicators across North America

Product Description FIRM-FILL® SCM-750 is a nominal 3/4” (19 mm), entangled polymeric filament sound control mat designed to limit impact noise between floors. Designed for critical applications in which FIRM-FILL® Gypsum Concrete will be utilized. Use in conjunction with a minimum 1-1/2” FIRM-FILL® Gypsum Concrete topping.

Limitations • Shall not be used in exterior locations, below grade or where continuous exposure to moisture is likely. • Shall not be used without a FIRM-FILL® Gypsum Concrete topping. • Structure shall be designed so that deflection does not exceed L/360 live or dead load. Certain floor coverings, such as marble, limestone, travertine and wood, may have more restrictive deflection limits. Consult the appropriate floor covering manufacturer for their recommendations. • Do not use mechanical fasteners to install FIRM-FILL® SCM-750, as mechanical fasteners conduct impact sound, reducing acoustical isolation. • FIRM-FILL® SCM-750 shall be installed with a perimeter isolation strip. • FIRM-FILL® SCM-750 is one component of an effective sound attenuation control system. Care must be taken in the installation of all components to ensure the ultimate design performance. Published acoustical and fire system tests were conducted under controlled laboratory and/or field conditions and reflected results are applicable only to those specific assemblies.

Installation Before, during and after installation, the building must be enclosed and the temperature maintained at a minimum of 50°F (10°C). Prior to installation, the subfloor shall be structurally sound (L/360), broom cleaned, dry and free from oil, grease, paraffin, laitance, wax or other contaminants. Attach perimeter isolation strip or approved alternative to the walls, conduit, flanges, ballasts, etc. in order to isolate or break the vibration transmission path between the floor and wall. Reinforcement is recommended in doorways and other high traffic or transition areas.

128

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-750 | © 2017


SUBMITTAL FORM INSTALLATION(cont.) FIRM-FILL® SCM-750 is laid directly over the concrete, plywood or OSB subfloor, with the green mesh down and white/green fabric side up. It should be pushed up tightly to the isolation barrier. Alternately, the FIRMFILL® SCM-750 may be pushed up tightly to the gypsum wall board when the isolation barrier installed is FIRMFILL® Perimeter Isolation. The gap between the floor and wall shall not exceed 0.25” (6 mm). FIRM-FILL® SCM-750 edge must be placed adjacent to other pieces without any gap. Rolls are manufactured with the self-adhesive selvage edge folded over on the fabric top. When unrolled, the selvage edge remains in position. Starting at the base of the roll, smooth the selvage edge to the adjacent piece. If necessary, tape (duct tape or 2” [51 mm]-wide tape) the 3” (76 mm) fabric overlaps snug to the fabric on the adjoining FIRMFILL® SCM-750 strip. Tape all seams to prevent penetration into the core material during pour. Double tape seams if necessary. Finished floor coverings can be installed when the FIRM-FILL® Gypsum Concrete is completely dry. Consult flooring contractor for acceptable levels of moisture and recommended procedures to test for dryness. Reference Hacker Industries, Inc.’s Guidelines for Installing Finished Floor Coverings. This guideline is not a warranty and shall be used as a guideline only. See ASTM F2419.

Product Data Core Thickness: Roll Weight: Packaging Length: Core Width: Total square feet:

3/4 in (19 mm) nominal 39 lb (17.2 kg) 80 ft (24.5 m) 60 in (149 cm) 400 ft² (37.16 m²)

UL Fire Rated Designs PURPOSE STATEMENT/DISCLAIMER These guidelines are designed to provide the architectural and building communities with detailed performance data on Hacker Industries, Inc.’s comprehensive portfolio of UL Fire Rated Designs. The tests for the assemblies included in these guidelines were conducted in a laboratory setting per ASTM C177 and E84. This guideline is not a warranty and should be used as a guideline only. The architects’ and general contractors’ recommendations supersede these guidelines. Field performance may vary. Subject to express Warranty stated on Hacker Industries, Inc.’s website. Hacker Industries, Inc. regularly performs fire (UL) testing to ensure performance standards for our products. Firm Fill® SCM (sound control mats), including Firm-Fill® SCM-750, were tested under the following UL Fire Rated Designs. UL Fire Rated Designs Nominal Wood L006, L201, L202, L206, L208, L209, L210, L211, L212, L501, L502, L503, L504, L505, L506, L507, L508, L509, L510, L511, L512, L513, L514, L515, L516, L517, L519, L520, L522, L523, L525, L526, L532, L533, L535 , L536, L537, L540, L541, L545, L557, L569, L588, L590, L593, L598, M504, M517, M519, M530, M531, M517 Open Web L521, L528, L529, L534, L542, L546, L550, L558, L563, L574, L576, L577, L579, L583, L585, L592, M500, M503, M508 I-Joist L518, L530, L538, L547, L556, L570, L581, L589, M502, M506, M512 Steel Deck G230, G516, G524, G553, G561, G565, G566, G568, G587, G594, G595 Steel Joist L524, L527, L539, L543, L549, L551, L552, L564, M505, M511, M513, M515, M534 Concrete J917, J919, J920, J924, J927, J931, J957, J991, J994

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-750 | © 2017

129


SUBMITTAL FORM Warranty Subject to express warranty stated on Hacker Industries, Inc.’s website.

Submittal Approvals Project Name

Contractor/Architect

Signature

Date

PRODUCT INFORMATION

See www.HackerIndustries.com for current recommended product specifications and literature. FIRM-FILL® SCM-750, for use with Hacker Floor Underlayments, is a component in an overall floor/ceiling assembly. Its performance is affected by every other component and the likelihood of achieving code compliance is contingent upon many other trades, including framers, plumbers and drywall contractors. Developers and general contractors are responsible for building properly and testing field performance as soon as possible in order to ensure the reliability of the project. WARNING Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or construction errors that may occur. Please consult a professional acoustical consultant to ensure plans are proper and that the floor/ceiling assembly can perform to expectations.

TRADEMARKS FIRM-FILL®, GYP-SPAN®, Let Our Products Floor You™ and the associated logos are trademarks of Hacker Industries, Inc. LEED® is a registered trademark of the U.S. Green Building Council. WARRANTY HACKER INDUSTRIES, INC. SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, DIRECTLY OR INDIRECTLY SUSTAINED, NOR FOR ANY LOSS CAUSED BY APPLICATION OF THESE GOODS NOT IN ACCORDANCE WITH CURRENT PRINTED INSTRUCTION OR FOR OTHER THAN THE INTENDED USE. HACKER'S LIABILITY IS EXPRESSLY LIMITED TO REPLACEMENT OF DEFECTIVE GOODS. ANY CLAIM SHALL BE DEEMED WAIVED UNLESS MADE IN WRITING TO HACKER INDUSTRIES, INC. WITHIN 30 DAYS FROM DATE IT WAS, OR REASONABLY SHOULD HAVE BEEN, DISCOVERED. SAFETY FIRST Follow good safety/industrial hygiene practices during installation. Wear appropriate personal protective equipment. Read specs, MSDS and literature prior to specification and installation. © 2017 Hacker Industries, Inc., Newport Beach, CA.

130

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-750 | © 2017


RECOMMENDED SPECIFICATIONS PART I. GENERAL 1.1

Scope

The work of this section includes FIRM-FILL® SCM-750 to be placed under FIRM-FILL® Gypsum Concretes. 1.2

Qualifications

A. FIRM-FILL® SCM-750 shall be installed by trained Licensed Applicators of Hacker Industries, Inc.

B.

All materials specified herein shall be approved by Hacker Industries, Inc., Newport Beach, CA. All others must receive prior approval.

C.

Materials shall be delivered in their original, unopened containers with identification labels intact. Protect materials from exposure to harmful weather conditions and maintain at a minimum temperature of 50˚F (10˚C).

D.

Before, during and after installation the building interior shall be ventilated and heated to a minimum of 50°F (10°C) to assure completion of the drying process for the Hacker Floor Underlayment.

PART II. PRODUCTS 2.1

Product Description

FIRM-FILL® SCM-750 is a nominal 3/4” (19 mm), entangled polymeric filament sound control mat designed to limit impact noise between floors. Designed for critical applications in which FIRM-FILL® Gypsum Concrete will be utilized. Use in conjuction with a minimum 1-1/2” FIRM-FILL® Gypsum Concrete topping. 2.2

Product Limitations

A.

Shall not be used in exterior locations, below grade or where continuous exposure to moisture is likely.

B.

Shall not be used without a FIRM-FILL® Gypsum Concrete topping.

C.

Structure shall be designed so that deflection does not exceed L/360 live or dead load. Certain floor coverings such as marble, limestone, travertine and wood may have more restrictive deflection limits. Consult the appropriate floor covering manufacturer for their recommendations.

D.

Do not use mechanical fasteners to install FIRM-FILL® SCM-750, as mechanical fasteners conduct impact sound, reducing acoustical isolation.

E. FIRM-FILL® SCM-750 shall be installed with a perimeter isolation strip.

F. FIRM-FILL® SCM-750 is one component of an effective sound attenuation control system. Care must be taken in the installation of all components to ensure the ultimate design performance. Published acoustical and fire system tests were conducted under controlled laboratory or field conditions and reflect results applicable only to those specific assemblies.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-750 | © 2017

131


RECOMMENDED SPECIFICATIONS (CONT.)

PART III. PREPARATION 3.1

Condition of Subfloor

A.

Subfloor shall be structurally sound (L/360), broom clean, dry and free from oil, grease, paraffin, laitance, wax or other contaminants. Concrete substrate shall be 28 days or older.

B.

Leak prevention: All cracks and voids should be filled with a quick-setting patching or taping compound or equal where leakage may occur.

C.

Before installation, the GC shall inspect and approve the condition of the subfloor and test the existing subfloor for moisture.

3.2

Application

A.

Scheduling

1. Installation of FIRM-FILL® SCM-750 shall not begin until other trades are finished in the area. Protect FIRM-FILL® SCM-750 from trade traffic prior to application of FIRM-FILL® Gypsum Concretes.

Installation

B.

1. Perimeter Isolation Strip shall be properly installed in an “L” formation around areas where FIRM-FILL® SCM-750 will be installed, including any openings in the subfloor installation.

2. FIRM-FILL® SCM-750 is laid directly over the concrete, plywood or OSB subfloor, with the green mesh down and white/green fabric side up. It should be pushed up tightly to the isolation barrier that was previously installed around the perimeter of the floor; the gap between the floor and wall should not exceed 0.25“ (6 mm). Alternately, the FIRM-FILL® SCM-750 may be pushed up tightly to the gypsum wall board when the isolation barrier installed is FIRM-FILL® Perimeter Isolation. The gap between the floor and wall should not exceed 0.25” (6 mm). 3. FIRM-FILL® SCM-750 edge must be placed adjacent to other pieces without any gap. Rolls are manufactured with the self-adhesive selvage edge folded over on the fabric top. If necessary, tape (duct tape or 2” [51 mm]-wide tape) the 3” (76 mm) fabric overlaps snug to the fabric on the adjoining FIRM-FILL® SCM-750 strip. Tape all seams to prevent penetration into the core material during pour. Double tape seams if necessary. When unrolled, the selvage edge remains in that position. Starting at the base of the roll, smooth the selvage edge to the adjacent piece. 3.3

Application of FIRM-FILL® Brand Gypsum Concretes

A.

Taping and seams of FIRM-FILL® SCM-750 shall be checked and approved by the GC prior to the installation of FIRM-FILL® Gypsum Concretes.

B.

Install FIRM-FILL® Gypsum Concretes at a minimum thickness of 1-1/2”.

C.

Protection: After installation, temporary wooden planking shall be placed by GC wherever the underlayment is subject to wheeled loads.

132

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-750 | © 2017


RECOMMENDED SPECIFICATIONS (CONT.)

D.

Drying: The GC shall provide continuous ventilation and adequate heat to rapidly remove moisture from the area until the underlayment is dry. If necessary, the GC shall provide mechanical ventilation and heat. Do not install finished floor coverings until the FIRM-FILL® Gypsum Concrete has been tested for dryness. Consult flooring contractor for recommended procedures to test for acceptable moisture levels. To avoid potential problems during the drying process, the GC shall consult Hacker Industries, Inc.’s Drying Conditions Flyer and Hacker Industries, Inc.’s website for additional information.

3.4

Preparation for Installation of Floor Coverings

A.

Sealing: Any areas where the underlayment surface has been damaged shall be cleaned and sealed. The floor covering manufacturer’s specificatiions and requirements suspersede these recommendations.

B.

Floor Covering Procedures: See Hacker Industries, Inc.’s Guidelines for Installing Finished Floor Coverings. The guideline is not a warranty and shall be used as a guideline only. See ASTM F2419.

C.

After finished floor covering is installed, trim the perimeter isolation strip below the finished flooring. Fill the groove with a bead of acoustical sealant or elastomeric sealant. Do not allow ceramic tile, grout or FIRM-FILL® Gypsum Concrete to come in contact with the wall. Shim the molding above the finished floor covering and caulk with an acoustical sealant.

3.5

Field Quality Control

Sound tests on underlayment systems have been conducted under laboratory and field conditions. Contact Hacker Industries, Inc. at (800) 642-3455 for information. Note: Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or construction errors that may occur. Please consult a professional acoustical consultant to ensure plans are proper and that the floor/ceiling assembly can perform to expectations.

Warranty: Hacker Industries, Inc. warrants Hacker Floor Underlayments (HFU) to be free from manufacturing defects, and when properly prepared and installed according to approved specified methods, HFU will attain minimum physical specifications as stated by Hacker Industries, Inc.’s most recent literature. Hacker Industries, Inc.’s obligation shall be limited to the replacement of the bagged product only and is subject to notice and inspection requirements. This warranty is in lieu of all other warranties, express or implied, including the warranties of merchantability and fitness for a particular purpose and all other obligations or liabilities.

Hacker Industries, Inc. | Architect Binder | Firm-Fill® SCM-750 | © 2017

133


HACKER SOUND MAT II HACKER SOUND MAT II, to create a quieter living environment while meeting demanding project specifications in multi-family construction. HACKER SOUND MAT II, a recycled rubber sound control mat, installed under a FIRM-FILL® Gypsum Concrete Floor Underlayment to produce an exceptional vibration isolation floor system. • Helps contribute towards LEED points • Specify with FIRM-FILL® Gypsum Concrete Floor Underlayments for additional LEED credits • Reduces sound transmission between floors; improves STC and IIC ratings • Over 100 UL Fire Rated Design listings • System rated for commercial and residential use ASTM C627 • Installed by trained Licensed Applicators


1 - FLOOR COVERING / 2 - FIRM-FILL® BRAND GYPSUM CONCRETE / 3 - HACKER SOUND MAT II / 4 - PLYWOOD OR OSB / 5 - NOMINAL WOOD JOIST / 6 - BATT INSULATION / 7 - PARALLEL CHORD TRUSS / ® BRAND 8 - TJI JOIST / 9 COVERING - RESILIENT CHANNEL / 10 - GYPSUM WALLBOARD / 11 - 6” CONCRETE / 3 - HACKER SOUND MAT II / 4 - PLYWOOD OR OSB / 5 - NOMINAL WOOD JOIST 1 -® FLOOR / 2 - FIRM-FILL GYPSUM CONCRETE

6 - BATT INSULATION / 7 - PARALLEL CHORD TRUSS / 8 - TJI ® JOIST / 9 - RESILIENT CHANNEL / 10 - GYPSUM WALLBOARD / 11 - 6” CONCRETE

Performance in wood-frame and structures concrete Performance

© 2017 Hacker Industries, Inc. FIRM-FILL® and the associated logos are trademarks of Hacker Industries, Inc., Newport Beach, CA.

in wood-frame and concrete structures

IIC +

STC +

Insulation Class (IIC) ratings

Transmission Class (STC) ratings

Improves Impact Improves Sound Allows vapor passInsulation Class Transmission Class through to prevent (IIC) ratings Impact (STC) ratingsSound trapped Improves Improves Allowsmoisture vapor to

pass through to prevent trapped moisture

Class A fire-rated product

Class A Fire-rated Product

Installed only by Hacker Industries’ Applicators Licensed Installed by

Hacker Industries trained Licensed Applicators

L/360

Requires dryin (building must be fully enclosed before installation)

Requires dry-in (building must be fully enclosed before installation)

May not be used as a vapor barrier

May not be used as a vapor barrier

Install isolation barrier around perimeter of floor

Install Hacker Sound Mat II with dimples down

Deflection must not exceed L/360 live or dead load

Deflection must not exceed L/360 live or dead load

Tape all seams with duct tape or 2” wide tape

Do not use Mechanical Fasteners

Do not use mechanical fasteners

Install FIRM-FILL® Brand Gypsum Concrete

Tape all seams with Install FIRM-FILL® Install isolation Install Hacker tape orSound 2” wideMatBrand barrier around Sound Mat II with Hacker Industries, Inc. | Architect Binderduct | Hacker II | ©Gypsum 2017 cellophane tape Concrete perimeter of floor dimples down

Must be used with FIRM-FILL® Gypsum Concrete

Must be used with FIRM-FILL® Brand Gypsum Concrete

Apply Hacker TopCoat™ SP when specified

Apply Hacker TopCoat™ SP if specified

Robinson Wheel tested Light Commercial

Robinson Wheel tested Light Commercial

Install finished floor covering only when completely dry

Install finished floor covering only when 135 completely dry


SUBMITTAL FORM TECHNICAL DATA Roll Weight Thickness

PROPERTIES 90 lb (40.8 kg) 1/4 in (6 mm) nominal

Width Core Color Packaging Length Total Square Feet Steiner Tunnel Test Pill Test DOC-FF 1-70 Compression Set 601/12131

54 in (137.16 cm) Black recycled rubber 30 ft (9.14 m) 135 ft² (41.15 m²) Class B Passes 15%

Benefits • • • • • •

A 1/4” sound control mat designed to control noise in multi-family projects Integral part of an exceptional vibration isolation floor system Composed of recycled tire rubbers Specify with a FIRM-FILL® Gypsum Concrete Floor Underlayment Helps contribute points to LEED project certification Installed only by trained Licensed Applicators across North America

Product Description A durable, environmentally-friendly sound control mat composed of recycled rubber that helps increase STC and IIC values to create a quieter living environment. Ideal for all types of wood frame construction, Hacker Sound Mat II features a quick and easy dry laid installation. Specify Hacker Sound Mat II with a 1-1/4” FIRMFILL® Gypsum Concrete topping for the ultimate sound performance system. Limitations • Shall not be used in exterior locations, below grade or where continuous exposure to moisture is likely. • Shall not be used without a FIRM-FILL® Gypsum Concrete topping. • Structure shall be designed so that deflection does not exceed L/360 live or dead load. Certain floor coverings, such as marble, limestone, travertine and wood, may have more restrictive deflection limits. Consult the appropriate floor covering manufacturer for their recommendations. • Do not use mechanical fasteners to install Hacker Sound Mat II, as mechanical fasteners conduct impact sound, reducing acoustical isolation. • Hacker Sound Mat II shall be installed with a perimeter isolation strip. • Hacker Sound Mat II is one component of an effective sound attenuation control system. Care must be taken in the installation of all components to ensure the ultimate design performance. Published acoustical and fire system tests were conducted under controlled laboratory and/or field conditions and reflected results are applicable only to those specific assemblies. Installation Before, during and after installation, the building must be enclosed and the temperature maintained at a minimum of 50°F (10°C). Prior to installation, the subfloor shall be structurally sound (L/360), broom cleaned, dry and free from oil, grease, paraffin, laitance, wax or other contaminants.

136

Hacker Industries, Inc. | Architect Binder | Hacker Sound Mat II | © 2017


SUBMITTAL FORM

HACKER SOUND MAT II

INSTALLATION(cont.) Attach perimeter isolation strip or approved alternative to the walls, conduit, flanges, ballasts, etc. in order to isolate or break the vibration transmission path between the floor and wall. Reinforcement is recommended in doorways and other high traffic or transition areas. Lay Hacker Sound Mat II onto the subfloor with dimples DOWN. The mat shall lay flat, even and uniform. Hacker Sound Mat II shall be pushed up tightly to the isolation barrier previously installed around the perimeter of the floor. Use a high-quality duct tape to tape the seams. Install FIRM-FILL® Gypsum Concrete at a minimum of 1-1/4” (32 mm). Refer to Hacker Industries, Inc. most recent FIRM-FILL® Gypsum Concrete underlayment recommended specifications.

Finished floor coverings can be installed when the FIRM-FILL® Brand Gypsum Concrete is completely dry. Consult flooring contractor for recommended procedures to test for dryness and acceptable levels of moisture. Reference Hacker Industries, Inc.’s Guidelines for Installing Finished Floor Coverings. This guideline is not a warranty and shall be used as a guideline only. See ASTM F2419. Product Data Core Thickness: Roll Weight: Packaging Length: Core Width: Total square feet:

1/4 in (6 mm) nominal 90 lb (40.8 kg) 30 ft (9.14 m) 54 in (137.16 cm) 135 ft² (41.15 m²)

Sound Test & UL Fire Rated Designs PURPOSE STATEMENT/DISCLAIMER These guidelines are designed to provide the architectural and building communities with detailed performance data on Hacker Industries, Inc.’s comprehensive portfolio of sound attenuation tests and UL Fire Rated Designs. The tests for the assemblies included in these guidelines were conducted in a laboratory setting per ASTM C177, E84, E90, E492 and E2179. These guidelines are not warranties and should be used as guidelines only. The architects’ and general contractors’ recommendations supersede these guidelines. Field performance may vary. Subject to express Warranty stated on Hacker Industries, Inc.’s website. Hacker Industries, Inc. regularly performs acoustical testing and fire (UL) testing to ensure performance standards for our products. Firm Fill® SCM (sound control mats), including Hacker Sound Mat II, were tested acoustically with the following floor assemblies and performed as noted.

Hacker Industries, Inc. | Architect Binder | Hacker Sound Mat II | © 2017

137


Hacker Industries, Inc.

Aco

SUBMITTAL FORM Corrugated Metal Deck

Sound System 1: Hacker Sound Mat II, 1” (25 mm) FIRM-FILL® CMD Gypsum Concr

Subfloor topping: 1” (25 mm) FIRM-FILL Subfloor isolation: 1/4” (6 mm) Hacker S Subfloor: 14 mm deep 22 msg galvanize Insulation: 3-1/2“ (89 mm) unfaced fiber Joist: Dietrich TradeReady 16 gauge met Ceiling isolation: Clark Dietrich RCSD res Ceiling: 1 layer 5/8” (16 mm) type C gyp

Contributes points to LEED® certifica

Hacker Sound Mat II – Corrugated Metal Deck Subfloor Topping 1” (25 mm) FIRMFILL® CMD Gypsum Concrete

Sound Mat 1/4" (6 mm) Hacker Sound Mat II

Subfloor Insulation

Truss

Ceiling Isolation

Ceiling

Finish

Sound Rating STC

IIC

14 mm 3-1/2" Dietrich Clark 1 layer 5/8" 13 mm 61 Tile Flooring mm QT4010 deep (89 mm) 13 mm QuarryDietrich (16 over mm) 10 Quarry Tile 22 msg unfaced 13 mm QuarryRCSD typeover C 10 Flooring Tile Flooring mm QT4010 galvanized fiberglass Resilient gypsum Over 10 corrugated batt Channel board mm HSM fluting insulation I** steel 13 mm -decking Quarry Tile Flooring Over 10 mm HSM I**

--

FINISH

58

Report #

STC

IIC

REP

61 --

-58

500 700

5008041

7008100

Contributes points to LEED® certification. UL Fire Rated Designs Steel Deck G230, G516, G524, G553, G561, G565, G566, G568, G587, G594, G595 Steel Joist L524, L527, L539, L543, L549, L551, L552, L564, M505, M511, M513, M515, M534

*Tested in accordance with ASTM E2179 - Standard Test Method for Laboratory Measurement of Effectiveness of Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors.

138

These guidelines shall only be a resource and are not a guarantee of performance. FIRM-FILL® SCM Underlayments are only one acoustical performance is affected by every other component. The likelihood of achieving code compliance is contingent upon ma plumbers and drywall contractors. Developers and general contractors are responsible for building properly and testing field performa of the project. Laboratory tests are notInc. a guarantee of field performance the issuesMat notedIIabove many other design an Hacker Industries, | Architect Binder | because HackerofSound | © and 2017 a professional acoustical consultant to assure specifications are written correctly and that the floor/ceiling assembly can perform to ex ®

®


HACKER SOUND MAT II

SUBMITTAL FORM Warranty Subject to express warranty stated on Hacker Industries, Inc.’s website.

Submittal Approvals Project Name Contractor/Architect

Signature

Date

The sound test acoustical guidelines shall only be a resource and are not a guarantee of performance. FIRM-FILL® SCM Underlayments are only one component in an overall floor/ceiling assembly. Their acoustical performance is affected by every other component. The likelihood of achieving code compliance is contingent upon many other trades including (but not limited to) framers, plumbers and drywall contractors. Developers and general contractors are responsible for building properly and testing field performance as soon as possible in order to ensure the reliability of the project. Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or construction errors that may occur. Please consult a professional acoustical consultant to assure specifications are written correctly and that the floor/ceiling assembly can perform to expectations. Field performance testing shall be done to ensure reliability of design prior to occupancy. © 2017 Hacker Industries, Inc. FIRM-FILL®, GYP-SPAN® and the associated logos are the registered trademarks of Hacker Industries, Inc. PRODUCT INFORMATION See www.HackerIndustries.com for current recommended product specifications and literature. Hacker Sound Mat II, for use with Hacker Floor Underlayments, is a component in an overall floor/ceiling assembly. Its performance is affected by every other component and the likelihood of achieving code compliance is contingent upon many other trades, including framers, plumbers and drywall contractors. Developers and general contractors are responsible for building properly and testing field performance as soon as possible in order to ensure the reliability of the project. WARNING Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or construction errors that may occur. Please consult a professional acoustical consultant to ensure plans are proper and that the floor/ceiling assembly can perform to expectations.

TRADEMARKS FIRM-FILL®, GYP-SPAN®, Let Our Products Floor You™ and the associated logos are trademarks of Hacker Industries, Inc. LEED® is a registered trademark of the U.S. Green Building Council. WARRANTY HACKER INDUSTRIES, INC. SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, DIRECTLY OR INDIRECTLY SUSTAINED, NOR FOR ANY LOSS CAUSED BY APPLICATION OF THESE GOODS NOT IN ACCORDANCE WITH CURRENT PRINTED INSTRUCTION OR FOR OTHER THAN THE INTENDED USE. HACKER'S LIABILITY IS EXPRESSLY LIMITED TO REPLACEMENT OF DEFECTIVE GOODS. ANY CLAIM SHALL BE DEEMED WAIVED UNLESS MADE IN WRITING TO HACKER INDUSTRIES, INC. WITHIN 30 DAYS FROM DATE IT WAS, OR REASONABLY SHOULD HAVE BEEN, DISCOVERED. SAFETY FIRST Follow good safety/industrial hygiene practices during installation. Wear appropriate personal protective equipment. Read specs, MSDS and literature prior to specification and installation. © 2017 Hacker Industries, Inc., Newport Beach, CA.

Hacker Industries, Inc. | Architect Binder | Hacker Sound Mat II | © 2017

139


RECOMMENDED SPECIFICATIONS PART I. GENERAL 1.1

Scope

The work of this section includes Hacker Sound Mat II to be placed under FIRM-FILL® Gypsum Concretes. 1.2

Qualifications

A.

Hacker Sound Mat II shall be installed by trained Licensed Applicators of Hacker Industries, Inc.

B.

All materials specified herein shall be approved by Hacker Industries, Inc., Newport Beach, CA. All others must receive prior approval.

C.

Materials shall be delivered in their original, unopened containers with identification labels intact. Protect materials from exposure to harmful weather conditions and maintain at a minimum temperature of 50˚F (10˚C).

D.

Before, during and after installation the building interior shall be ventilated and heated to a minimum of 50°F (10°C) to assure completion of the drying process for the Hacker Floor Underlayment.

PART II. PRODUCTS 2.1

Product Description

A durable, environmentally-friendly sound control mat composed of recycled rubber that helps increase STC and IIC values, creating a quieter living environment. Ideal for all types of woodframe construction, Hacker Sound Mat II features a quick and easy dry laid installation. Specify Hacker Sound Mat II with a 1-1/4” FIRMFILL® Gypsum Concrete topping for the ultimate sound performance system. 2.2

Product Limitations

A.

Shall not be used in exterior locations, below grade or where continuous exposure to moisture is likely.

B.

Shall not be used without a FIRM-FILL® Gypsum Concrete topping.

C.

Structure shall be designed so that deflection does not exceed L/360 live or dead load. Certain floor coverings such as marble, limestone, travertine and wood may have more restrictive deflection limits. Consult the appropriate floor covering manufacturer for recommendations.

D.

Do not use mechanical fasteners to install Hacker Sound Mat II, as mechanical fasteners conduct impact sound, reducing acoustical isolation.

E.

Hacker Sound Mat II shall be installed with a perimeter isolation strip.

F.

Hacker Sound Mat II is one component of an effective sound and fire control system. Care must be taken in the installation of all components to assure the ultimate design performance. Published acoustical and fire system tests were conducted under controlled laboratory or field conditions and reflect results applicable only to those specific assemblies.

140

Hacker Industries, Inc. | Architect Binder | Hacker Sound Mat II | © 2017


RECOMMENDED SPECIFICATIONS (CONT.)

HACKER SOUND MAT II

PART III. PREPARATION 3.1

Condition of Subfloor

A.

Subfloor shall be structurally sound (L/360), broom clean, dry and free from oil, grease, paraffin, laitance, wax or other contaminants. Concrete substrate shall be 28 days or older and meet ASTM F710.

B.

Before installation, the GC shall inspect and approve the elevations and subfloor and test the existing subfloor for moisture.

C.

When required, the GC shall install bulkheads in areas where the Hacker Sound Mat II stops and meets the carpet and pad areas.

D.

All cracks and voids should be filled with a quick-setting patching or taping compound or equal where leakage may occur.

3.2

Application

A.

Scheduling: Installation of Hacker Sound Mat II shall not begin until other trades are finished in the area. Protect Hacker Sound Mat II from trade traffic prior to application of FIRM-FILL® Gypsum Concretes.

B.

Installation

1. Attach Perimeter Isolation Strip or approved alternative to the wall around areas where Hacker Sound Mat II will be installed, including any openings in the subfloor installation, in order to isolate or break the vibration transmission path between the floor and the wall. Reinforcement is recommended in doorways and other high traffic areas.

2. Lay Hacker Sound Mat II onto the subfloor with dimples DOWN. The mat shall lie flat, even and uniform. Hacker Sound Mat II shal be pushed up tightly to the isolation barrier previously installed around the perimeter. Use a high-quality tape (duct tape or 2" (51mm) -wide tape) to tape the seams.

3.3

Application of FIRM-FILL® Brand Gypsum Concretes

A.

Taping and seams of Hacker Sound Mat II shall be checked and approved by the GC prior to the installation of FIRM-FILL® Gypsum Concretes.

B.

Install FIRM-FILL® Gypsum Concretes at a minimum thickness of 1-1/4” (32 mm). Refer to Hacker Industries, Inc.’s most recent FIRM-FILL® Floor Underlayments recommended specifications.

C.

Protection: After installation, temporary wooden planking shall be placed by GC wherever the underlayment is subject to wheeled loads.

D.

Drying: The GC shall provide continuous ventilation and adequate heat to rapidly remove moisture from the area until the underlayment is dry. If necessary, the GC shall provide mechanical ventilation and heat. Do not install finished floor coverings until the FIRM-FILL® Gypsum Concrete has been tested for dryness. Consult flooring contractor for recommended procedures to test for acceptable moisture levels. To avoid potential problems during the drying process, the GC shall consult Hacker Industries, Inc.’s Drying Conditions Flyer and Hacker Industries, Inc.’s website for additional information.

Hacker Industries, Inc. | Architect Binder | Hacker Sound Mat II | © 2017

141


RECOMMENDED SPECIFICATIONS (CONT.) 3.4

Preparation for Installation of Floor Coverings

A.

Sealing: Any areas where the underlayment surface has been damaged shall be cleaned and sealed. The floor covering manufacturer’s specifications and requirements supersede these recommendations.

B.

Floor Covering Procedures: See Hacker Industries, Inc.’s Guidelines for Installing Finished Floor Coverings. The guideline is not a warranty and shall be used as a guideline only. See ASTM F2419.

C.

3.5

After finished floor covering is installed, trim the perimeter isolation strip below the finished flooring. Fill the groove with a bead of acoustical sealant or elastomeric sealant. Do not allow ceramic tile, grout or FIRM-FILL® Gypsum Concrete to come in contact with the wall. Shim the molding above the finished floor covering and caulk with an acoustical sealant.

Field Quality Control

Sound tests on underlayment systems have been conducted under laboratory and field conditions. Contact Hacker Industries, Inc. at (800) 642-3455 for information. Note: Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or construction errors that may occur. Please consult a professional acoustical consultant to ensure plans are proper and that the floor/ceiling assembly can perform to expectations.

Warranty: Hacker Industries, Inc. warrants Hacker Floor Underlayments (HFU) to be free from manufacturing defects, and when properly prepared and installed according to approved specified methods, HFU will attain minimum physical specifications as stated by Hacker Industries, Inc.’s most recent literature. Hacker Industries, Inc.’s obligation shall be limited to the replacement of the bagged product only and is subject to notice and inspection requirements. This warranty is in lieu of all other warranties, express or implied, including the warranties of merchantability and fitness for a particular purpose and all other obligations or liabilities.

142

Hacker Industries, Inc. | Architect Binder | Hacker Sound Mat II | © 2017


SOUND CONTROL MAT PROJECT REFERENCES Hacker Industries, Inc. continues to provide solutions for maximizing sound control in multi-family projects, commercial buildings, and custom homes. This is a sample of completed projects utilizing a Hacker Acoustical Control Mat with a Hacker Floor Underlayment. Contractor: A.G. Spanos Project: Corbin Crossing Location: Overland Park, Kansas Description: 72,600 ft² FIRM-FILL® SCM with 3/4” FIRM-FILL® Gypsum Concrete topping Contractor: Ambling Construction Project: Woodlawn Terrace Location: Valdosta, Georgia Description: 38,200 ft² FIRM-FILL® SCM with 3/4” FIRM-FILL® Gypsum Concrete topping Contractor: Barnhill Contracting Project: West Village Renovation Location: Durham, North Carolina Description: 190,000 ft² Hacker Sound Mat II with 1” FIRM-FILL® 3310+ topping Contractor: Camden Development Project: Camden at Lake Nona Location: Orlando, Florida Description: 86,264 ft² FIRM-FILL® SCM with 3/4” FIRM-FILL® 3310+ topping Contractor: D.R. Horton Project: Grand at Riverdale Location: Riverdale, New Jersey Description: 350,000 ft² Hacker Sound Mat II with 1” FIRM-FILL® 3310+ topping Contractor: Hamel Builders Project: The Severna Location: Washington, D.C. Description: 5,808 ft² of FIRM-FILL® SCM with FIRM-FILL® 3310+ topping Contractor: Gables Construction Project: Gables Centerpointe Location: Fairfax, Virginia Description: 29,019 ft² FIRM-FILL® SCM with 3/4” FIRM-FILL® Gypsum Concrete topping Contractor: Juneau Construction Project: Albany State University Student Housing Location: Albany, Georgia Description: 113,000 ft² FIRM-FILL® SCM with 3/4” FIRM-FILL® 3310+ topping Contractor: MT Builders Project: Sagewood Luxury Apts; Retreat at Westpoint; Waterford at Peoria Location: Phoenix, Arizona Description: 420,000 ft² Hacker Sound Mat II with 1” FIRM-FILL® 2010 topping Contractor: Planning Design Build Project: Kalahari Kondominiums Location: Lake Delton, Wisconsin Description: 20,000 ft² Hacker Sound Mat II with 1-1/2” FIRM-FILL® 3310+ topping

Hacker Industries, Inc. | Architect Binder | Sound Control Mat Project References | © 2017 143

143


Hacker Industries, Inc. D I V I S I O N 03 54 13 G Y P S U M C E M E N T U N D E R L AYM E N T

Quick Reference Sheet


QUICK REFERENCE | GYPSUM CEMENT UNDERLAYMENT 03 54 13 1. Product Name Hacker Floor Underlayments FIRM-FILL® Gypsum Concrete FIRM-FILL® 2010+ FIRM-FILL® 3310+ FIRM-FILL® High Strength FIRM-FILL® 4010+ FIRM-FILL® CMD GYP-SPAN® Radiant Hacker Sound Mat II FIRM-FILL® SCM Hacker Floor Primer Hacker Floor Sealer Hacker TopCoat™ SP *Note: For cementitious applications, consult TRUE-SCREED® CLU Spec Data Sheet. 2. Supplier Hacker Industries, Inc. 1600 Newport Center Drive, Suite 275 Newport Beach, CA 92660 USA Phone (949) 729-3101 (800) 642-3455 Fax (949) 729-3108 www.HackerIndustries.com e-mail: info@HackerIndustries.com 3. Product Description BASIC USE Hacker Floor Underlayments (HFU) are lightweight, highstrength, durable, nonstructural cementitious underlayments for use in multi-family, residential, commercial and radiant heating projects for both new construction and renovation. Trained Licensed Applicators can install up to 40,000 ft2 (3716 m2) per day. The finished products provide a superior crackresistant surface that is integral to a fire and sound rated system. Since 1983, Hacker Industries, Inc. has provided the most costeffective and high strength underlayments in the industry. With the proven performance

of over two billion square feet installed nationwide, HFU are appropriate for use over concrete, wood, steel deck or radiant substrates. With proper preparation, virtually any type of finished floor covering can be installed over HFU. All HFU meet ASTM F2419. (See Technical Data). COMPOSITION & MATERIALS FIRM-FILL® Gypsum Concretes and GYP-SPAN® Radiant are mixed with washed plaster or masonry sand, per ASTM C33, and potable water to form HFU. TYPES FIRM-FILL® Gypsum Concrete Designed for use in multi-family housing to attain sound and fire ratings. 1200 2000 psi (8.3-13.8 MPa). • FIRM-FILL® 2010+ Additional surface hardness and higher compressive strength. 2000-3200 psi (13.8-22.0 MPa). • FIRM-FILL® 3310+ An exceptionally smooth, rocksolid, surface over wood subfloors. 3000- 3900 psi (20.6-26.8 MPa). FIRM-FILL® High Strength For resurfacing damaged, uneven or cracked concrete floors and planks. 2500-3800 psi (17.2-26.2 MPa). • FIRM-FILL® 4010+ Offers superior bonding capabilities for thin capping of concrete floors. 4000-5200 psi (27.5- 34.4 MPa). FIRM-FILL® CMD For cold-formed steel frame construction with a corrugated steel deck. Min. 3500 psi (24.1 MPa).

GYP-SPAN® Radiant Designed for use with radiant heat systems, enhanced thermal mass and heat transfer. 2000-3200 psi (13.8-22.1 MPa). Hacker Sound Mat II Sound control mat; composed of recycled rubber; increases STC and IIC ratings. • FIRM-FILL® SCM A range of dimensional acoustical control mats. APPLICATION THICKNESS Minimum application thickness of HFU is: • Over wood: 3/4” (19 mm) of HFU • Over concrete slabs: HFU may be featheredged in transition areas • Over radiant heat tubes: Minimum 3/4” (19 mm) on top of radiant tubes • Over Sound Control Mats: See supplier recommendations for thickness • Maximum thickness: 3-1/2” (89 mm) • Over corrugated steel deck: 1” (25 mm) over top of flutes LIMITATIONS • Do not use HFU in exterior locations. • HFU require a finished floor covering. • Gypsum based systems shall not be used below grade or where prolonged exposure to moisture is likely. • Subfloor must support design loads with maximum L/360 deflection. • HFU above crawl spaces must be protected by a vapor barrier. • Do not apply less than 1-1/2” (38 mm) of HFU on plastic vapor barrier.

SPEC-DATA® and MANU-SPEC® are registered trademarks of Reed Elsvier, Inc. FIRM-FILL® GYP-SPAN®, TRUE-SCREED® and the associated logos are registered trademarks of Hacker Industries, Inc., Newport Beach, CA. © 2017 Hacker Industries, Inc. Product Contributes towards LEED® credits.

Hacker Industries, Inc. | Architect Binder | Spec Data | © 2017

145


03 54 13 QUICK REFERENCE | GYPSUM CEMENT UNDERLAYMENT 03 54 13

Gypsum C

Hacker Industries, Inc.

• HFU are one component of an effective sound and fire control system. Care must be taken in the installation of all components to ensure the ultimate design performance. Published acoustical and fire system tests were conducted under controlled laboratory or field conditions and reflect results applicable only to those specific assemblies. 4. Technical Data APPLICABLE STANDARDS • ASTM F2419 Standard Practice for Installation of Thick Poured Gypsum Concrete Underlayments and the Preparation of the Surface to Receive Resilient Flooring • ASTM C472 Modified Standard Test Methods for Physical Testing of Gypsum, Gypsum Plasters and Gypsum Concrete • ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials • 2012 Tile Council of North America Handbook Installation Methods F180, F200, RH111, and RH122. WEIGHT • FIRM-FILL® Gypsum Concrete – 3/4” (19 mm) thickness weighs 7 psf (34.2 kg/m2) • FIRM-FILL® 2010+ – 3/4” (19 mm) thickness weighs 7.2 psf (35.2 kg/m2) • FIRM-FILL® 3310+ – 3/4” (19 mm) thickness weighs 7.6 psf (37.1 kg/m2) • FIRM-FILL® High Strength – 3/4” (19 mm) thickness weighs 7.7 psf (37.6 kg/m2) • FIRM-FILL® 4010+ - 1/2” (12 mm) thickness weighs 5.3 psf (25.8 kg/m2) • GYP-SPAN® Radiant – 1-1/2”

(38 mm) thickness weighs 14.6 psf (71.3 kg/m2)

3/4” (19 MM) HACKER FLOOR UNDERLAYNMENT

FLOOR COVERING

5/8” (16 MM) PLYWOOD

DENSITY 107-130 pcf (1682-2082 kg/m3) minimum dry density FIRE PERFORMANCE HFU are included in over 100 UL listings: G561, G565, G568, J917, J919, J920, J924, J927, J931, J957, J966, J991, J994, K906, L001, L004, L005, L006, L201, L202, L206, L208, L209, L210, L211, L212, L501, L502, L503, L504, L505, L506, L507, L508, L509, L510, L511, L512, L513, L514, L515, L516, L517, L518, L519, L520, L521, L522, L523, L524, L525, L526, L527, L528, L529, L530, L531, L532, L533, L534, L535, L536, L537, L538, L539, L540, L541, L542, L543, L544, L545, L546, L547, L548, L549, L550, L551, L552, L553, L555, L556, L557, L558, L559, L570, L574, L560, L562, L563, L571, L585, L590, L592, L593, L598, M502, M506, M508, M512, M513. Canada: L003, L201, L511, L512, M500, M501, M503, M505, M506, M507, M508, M509, M514, M518, M520.

APPROVALS • ICC-ES Legacy Report ER-4147 • City of Los Angeles RR No. 24540 • U.S. Department of Housing and Urban Development FHAHUD-1255 FIRE HAZARD CLASSIFICATION ASTM E84: Flamespread Index, 0; Fuel Contribution, 0; Smoke Density, 0. ACOUSTICAL PERFORMANCE HFU contribute to superior STC (Sound Transmission Class) and IIC (Impact Insulation Class) ratings. Additional sound reduction is achieved using a sound control mat with HFU.

2” x 10” (51 MM x 254 MM) WOOD JOIST RESILIENT CHANNEL 1/2” (13 MM) TYPE X OR 5/8” (16 MM) GYPSUM WALLBOARD OPTIONAL: SOUND CONTROL MAT

Canada: M501, M5 M509, M5

FIRE HA ASTM E8 Contribut

Figure 1: Wood System

FLOOR COVERING

L544, L54 L551, L55 L559, L57 L585, L59 M506, M5

MIN. 1” (25 MM) FIRM-FILL® CMD OVER TOP OF FLUTES CORRUGATED STEEL DECK 14” 14 GAUGE STEEL JOIST

ACOUST HFU con Transmis Insulation reduction mat with

RESILIENT CHANNEL

BATT INSULATION

GYPSUM WALLBOARD

OPTIONAL: SOUND CONTROL MAT

Figure 2: Corrugated Steel Deck

FLOOR COVERING

GYP-SPAN® RADIANT (THICKNESS DEPENDENT ON DIAMETER OF TUBES TUBES OR CABLES 5/8” (16 MM) PLYWOOD OR CONCRETE WOOD JOIST OR TRUSS SYSTEM 1/2” (13 MM) TYPE X OR 5/8” (16 MM) GYPSUM WALLBOARD

Figure 3: Radiant Heat System

FLOOR COVERING

STUD 1/2” (13 MM) OR 3/4” (19 MM) HACKER FLOOR UNDERLAYMENT PRECAST CONCRETE

OPTIONAL: SOUND CONTROL MAT

Figure 4: Concrete System

GYPSUM WALLBOARD

5. Insta SITE CO HFU sha unopened to elemen allow bag shelf life.

Building t above 50 installatio temperat and mate

PREPAR General C subfloor i are suitab ment. Su and comp wax, laita Subfloor the instal

APPLICA Prior to in must be e and door tubing ha constant from the complete Contracto

STUD FLOOR COVERING 1/8” (3 MM) TO 3-1/2” (89 MM) HACKER FLOOR UNDERLAYMENT

The follow conjuncti

Field Sam acco using

STRUCTURAL SUBFLOOR

Slump T being and

OPTIONAL: SOUND CONTROL MAT

Figure 5: Renovation

SPEC-DATA and MANU-SPEC are registered trademarks of Re ® and the associated SPEC-DATA® and MANU-SPEC® are registered trademarks of Reed Elsvier, Inc. FIRM-FILL® GYP-SPAN®, TRUE-SCREED logos are registered associated logos are registered trademarks of Hacker Industries, I trademarks of Hacker Industries, Inc., Newport Beach, CA. © 2017 Hacker Industries, Inc. ®

146

®

Hacker Industries, Inc. | Architect Binder | Spec Data | © 2017


QUICK REFERENCE | GYPSUM CEMENT UNDERLAYMENT 03 54 13 5. Installation SITE CONDITIONS HFU shall be delivered in original, unopened bags, stored away from exposure to elements and above 50˚F (10˚C). Do not allow bags to get wet. Do not use beyond shelf life. Building temperature shall be maintained above 50˚F (10˚C) before, during and after installation until the subfloor, ambient temperature and humidity have stabilized and material has completely dried. PREPARATION General Contractor shall confirm the subfloor is structurally sound and conditions are suitable for installation of floor underlayment. Subfloor must be dry, broom cleaned, and completely free of oil, grease, paraffin, wax, laitance and other contaminants. Subfloor shall be tested for moisture before the installation of HFU. APPLICATION Prior to installation of HFU, the building must be enclosed, including roof, windows and doors. Install HFU after radiant heat tubing has been put in place. Provide constant ventilation to remove moisture from the area until the underlayment is completely dry. If necessary, the General Contractor shall provide mechanical heat. The following tests shall be performed in conjunction with the installation of HFU: Field Samples:

Perform psi tests in strict accordance with ASTM C472 modified using 2” (51 mm) split brass molds. Slump Test: Test for slump as HFU are being installed using a 2” by 4” cylinder and plexiglass. The patty size shall be as stated by Hacker Industries, Inc.’s current literature. Dryness Test: Prior to the installation of finished floor goods, Hacker Industries, Inc. recommends that a moisture test be done. Consult floor covering manufacturer for recommended procedures to test for dryness and acceptable moisture levels. Calcium chloride is not an approved method. To avoid potential problems during the drying process, the General Contractor shall consult Hacker Industries, Inc.’s Drying Conditions Flyer and information contained on Hacker Industries, Inc.’s website for additional information concerning drying of this product. PROTECTION During construction, General Contractor shall place temporary wood planking in areas subject to wheeled or concentrated loads.

7. Warranty HACKER INDUSTRIES, INC. WARRANTS HFU TO BE FREE FROM MANUFACTURING DEFECTS, AND WHEN PROPERLY PREPARED AND INSTALLED ACCORDING TO APPROVED SPECIFIED METHODS, HFU WILL ATTAIN MINIMUM PHYSICAL SPECIFICATIONS AS STATED BY HACKER INDUSTRIES, INC.’S MOST RECENT LITERATURE. HACKER INDUSTRIES, INC.’S OBLIGATION SHALL BE LIMITED TO THE REPLACEMENT OF THE BAGGED PRODUCT ONLY AND IS SUBJECT TO NOTICE AND INSPECTION REQUIREMENTS. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND ALL OTHER OBLIGATIONS OR LIABILITIES. For Hacker Industries, Inc.’s BIM models and details, visit www.HackerIndustries.com or www.CADdetails.com.

BUILDING CODES Installation of HFU must comply with applicable local, state and national code requirements. 6. Availability & Cost HFU are only installed by trained Licensed Applicators. Contact Hacker Industries, Inc. for the applicator(s) in your area.

SPEC-DATA® and MANU-SPEC® are registered trademarks of Reed Elsvier, Inc. FIRM-FILL® GYP-SPAN®, TRUE-SCREED® and the associated logos are registered trademarks of Hacker Industries, Inc., Newport Beach, CA. © 2016 Hacker Industries, Inc.

Hacker Industries, Inc. | Architect Binder | Spec Data | © 2017

147


Hacker Industries, Inc. 1600 Newport Center Drive, Suite 275 Newport Beach, CA 92660 Tel: (800) 642-3455 / (949) 729-3101 www.hackerindustries.com info@hackerindustries.com

ARCHITECT BINDER


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.