We set your ideas in motion. We do not merely manufacture motors, but instead turn the ambitious concepts of our customers into modern, innovative and reliable products, which are unique and point the way to the future. We bring our customers closer to their goals with reliability, creativity and flexibility.
Business Units
Home Appliances
Serial Motors
New Businesses
Project Motors
Peripheral pumps AQUAMAT 1
Description, design and technical data
Materials of the pump parts: - Pump housing: gray iron - Motor housing: Al alloy - Shaft: stainless steel - Impeller: copper alloy Technical data - Flow: up to 85 l/min - Head: up to 70 m - Suction pressure: max 3 bar - Discharge pressure: max 10 bar - Water temperature: up to 50oC At the greatest head, the pump AQUAMAT absorbs the greatest power. For this reason the usage of the pump is allowed within the limits of the flow and the head designated on diagrams.
Pump designation
A - 9 8 9
T M T
Basic type Characteristics of pump size Single-phase or three-phase motor
Application Automatic pumps AQUAMAT are applied for supplying households, cottages, motels, farms with cold consumption water and they also can be used for irrigation. They pump water out of dug, drilled or driven wells, cisterns, tanks and brooks. Transported liquid Pump is used for transport of cold consumption water with allowed quantity of sand max 25 g/m3 and the greatest diameter of particles up to 0,04mm.
Design Pump is peripheral, single-stage, in monoblock execution with electric motor. Loose radial coupling of shaft and impeller enables seflpositioning of impeller in pump housing. Pump housing sealing is done by mechanical seal. At suction and discharge there are flanges with inner tube thread R1 1/4 ", which are intended for connection to the pipeline. This enables easy and simple mounting and dismounting of pump. The main parts of the pump are of high quality and assure long life practically without maintenance.
Electric motor data - Two pole single-phase or three-phase asynchronous motor - Rated voltage: 1x230V or 3x400V, 50Hz - Degree of mechanical protection: IP54 - Insulation class: F - Allowed ambient temperature: 40oC - Protection: pumps are delivered with motor without protection, so it is necessary to carry out the protection with motor protection switch
Standards and marks of quality Pumps AQUAMAT are in category of domestic appliances. They hold all necessary certificates and declarations in accordance with the directives of the European Union. According to the EU legislation, they carry the CE sign. They are attested by TĂœV Rheinland. Pumps meet the requirements of the following standards: - EN 60335-1 - EN 60335-2-41 - EN 55014-1 - EN 55014-2
Peripheral pumps AQUAMAT Diagrams of hydraulic characteristics
Diagrams of hydraulic characteristics J/kg
H m
HMAX
70
600
3,0
50
500
2,5
400
2,0
HMAX
30
300
9
A-
20
200
A-
9
1,5
A-8
1,0
QMAX
8
INPUT POWER
60
A-
HEAD
P1 kW
700
40
10
100
0
20
10
0
30
40
60
70
80
90
0
Q, l/min 3
Q, m /h
5
4
3
2
1
50
0,5
20
10
30
40
50
60
70
80
90 5
4
3
2
1
0
Q, l/min 3
Q, m /h
FLOW
FLOW
h
pS bar
% 100
10 9
80
8
STATIC PRESSURE p S*
90 70
EFFICIENCY
2
60
A-9
50
A-8
40 30 20 10 0
7 6
9
5
A-
A-8
4 3 2 1 0
0
20
10
0
1
30
40
50 3
2
60
70
80
90 5
4
Q, l/min
100
110
120
130
140
150
160
170
Q, m /h
*static pressure in the pump housing at the starting instant.
FLOW
The characteristics are valid for Hu=0 m, without resistance in the discharge pipe, for nominal voltage and up to 1000m above sea level.
Max suction head Type
Hu
180
STARTING VOLTAGE UZ
3
Flow Q, l/min 20
30
40
m
50 60 Head H, m
70
80
85
A-8 M(T)
7
–
38
30
20
10
0
–
–
A-9 M(T)
7,5
70
60
50
40
30
20
10
5
Note: All rights to change or complete the data preserved. Obligatory data are given on special request.
190 UZ, V
Peripheral pumps AQUAMAT 3
Measurement drawing, electrical characteristics and masses
Measurement drawing
D
96 20
H
HE
H1
H2
D
20
Suction port
44
Port for watering
Discharge port
AA
10
HA
40 B
C
A
BB
AB
L1
A1
Dimensions, electrical characteristics and masses
Type
Rated voltage U V
Output power* P2 kW
Allowed no. of starting per hour
A
A1
AA
AB
B
BB
C
H
H1
H2 HA HE
L1
D
Mass kg
mm " 4
16,0
A-8 M
230
0,75
40
125 178,5 38 155 100 130
107
80 191
60
9
190
335
R1 1 /
A-8 T
400
0,75
50
125 178,5 38 155 100 130
107
80 191
60
9
190
335
R1 1 /4 "
14,0
A-9 M
230
1,5
20
140
89
90 206
65 12 211
392
R1 1 /4 "
21,5
362
R1 1 /
"
16,5
A-9 T
400
1,5
30
140
191 191
40 180 125 155 40 180 100 130
* Output power of electric motor
Note: All rights to change or complete the data preserved. Obligatory data are given on special request.
89
90 206
65 12 211
4
Automatic pumps HIDROPAK 4
Designation, design and technical data
Design Pump is peripheral, single-stage in monoblock execution with electric motor, pressure tank and pressure switch which enables automatic pump operation. Pressure gauge serves only for running control. There are standard executions with single-phase and three-phase asynchronous electric motors. Materials of pump parts - Pump housing: gray iron - Motor housing: Al alloy - Shaft: stainless steel - Impeller: copper alloy Technical data - Standard measures of connectors: suction: R 1 1/4" discharge: R 1" - Flow: up to 70 l/min - Head: up to 45 m - Working pressure range : 1-4,5 bar - Suction height: up to 30 m - Water temperature: up to 50oC
Pump designation
H - 9
T
8 9
M T
INJ 4"
Basic type Characteristic of pump size Single-phase or three-phase motor Designation for injector* Note: *Only for pumps with injector.
Application Automatic pumps HIDROPAK are applied for supplying households, cottages, motels, farms with cold consumption water and they also can be used for irrigation. They pump water out of dug, drilled or driven wells with depth level up to 7,5 m. Pump with injector can pump water out from a depth level up to 30 m. Transported liquid Pump is used for transport of cold consumption water with allowed quantity of sand max 25 g/m3 and the greatest diameter of particles up to 0,04 mm.
Electric motor data - Two pole single-phase or three-phase asynchronous motor - Rated voltage: 1x230V, 50Hz or 3x400V, 50Hz - Degree of mechanical protection: IP54 - Insulation class: F - Protection: pumps are delivered with motor without protection, so it is necessary to carry out the protection with motor protection switch Standards and marks of quality Pumps HIDROPAK are in category of domestic appliances. They hold all necessary certificates and declarations in accordance with the directives of the European Union. According to the EU legislation, they carry the CE sign. They are attested by TĂœV Rheinland. Pumps meet the requirements of the following standards: - EN 60335-1 - EN 60335-2-41 - EN 55014-1 - EN 55014-2
Automatic pumps HIDROPAK 5
Installation
Pump installation in case of shallow wells Pumps are used for water level depth up to 7,5 m. For ground-floor or one-floor households, weekend houses, for water consumption up to 50 l/min, we recommend type H-8 M(T). For water consumption up to 70 l/min, we recommend type H-9 M(T), for larger households, small motels, etc. Note When distance between pump and well increases, suction height decreases for 1 m on every 10 m. This should be considered while determining the position of the pump. For very remote wells the pump has to be placed beside the well or an injector has to be used with increasing the diameter of the suction pipeline.
Straight-trough tap
"T" tap joint up to
1
Suction pipe 1 /4" (32mm) Well pipe
1
Non return valve 1 /4"
Suction pipe 1 from 1 /4" (32mm)
Suction basket with valve
up to
Pump installation in case of deep wells
up to Straight-trough tap 0,8 m
For water level depth up to 30 m and consumption up to 30 l/min, we recommend type H-9 M(T) INJ 4" (for larger households, small motels, small farms, etc). *When suction height is less then 30 m, pump can be placed on a distance more than 10 m from the well. Every decrease of suction height for 1 m allows increase of distance between pump and well for 10 m, but not more than 50 m.
Main well pipe 4" (100 mm) Suction pipe 11/4" (32 mm)
C
min 1,5 m
Recirculating pipe 1" (25 mm)
Note: All rights to change or complete the data preserved. Obligatory data are given on special request.
Automatic pumps HIDROPAK Measurement drawing and pump characteristics
Recirculating port
Measurement drawing PUMP Pressure gauge
Port for watering
INJECTOR FOR 4" WELLS
R1"
Discharge port
1
250
R1 /4"
380
R1"
R11/4"
Pressure switch
98
C
Suction port
Pump with electric motor
50
725
160
13 46
240
Suction pipe R11/4"
Recirculating pipe R1"
50
160
96
64
A
B
6
Dimensions, electrical characteristics and masses
Type
Nominal voltage U V
Output power P2 kW
A
B
C
Mass
mm
mm
mm
kg
H-8 M
230
0,75
390
490
540
26
H-8 T
400
0,75
390
490
540
26
H-9 M
230
1,1
400
500
550
28,5
H-9 T
400
1,1
400
500
550
26,5
Pump characteristics with injector for deep wells Type
suction height
2
4
6
8
10
12
45 -
35 45 -
20 35 -
0 25 40 -
15 35 40 -
5 27 36 -
Hu
H-9 T(M) INJ 4"
30 25 20 15 10
Flow Q, l/min 14 16 18 Head H, m 20 10 0 30 24 17 40 36 30
20
22
24
26
28
30
10 25
0 20
15
10
5
0
Pump characteristics for shallow wells
Flow Q, l/min Type
40
45
50
60
70
80
Head H, m H-8 T(M)
30
25
20
10
0
-
H-9 T(M)
-
45
40
30
20
10
1)
QH data are valid for altitude up to 1000m above sea level. Pump characteristics for shallow wells are for a suction height Hu=0 m.
Note: All rights to change or complete the data preserved. Obligatory data are given on special request.
ATB Group - a global player a company of A-TEC INDUSTRIES AG
Company locations Austria
Great Britain
Head office
ATB MORLEY Ltd. Bradford Road, West Yorkshire, LS28 6QA Leeds Phone: +44 113 257 1734 Fax: +44 113 257 0751 E-Mail: sales@uk.atb-motors.com
ATB AUSTRIA ANTRIEBSTECHNIK AG Hohenstaufengasse 7, 1010 Vienna Phone: +43 1 90250-0 Fax: +43 1 90250-110 E-Mail: info@atb-motors.com Http://www.atb-motors.com ATB MOTORENWERKE GmbH G.-Bauknecht-Straße 1, A-8724 Spielberg Phone: +43 3577 757-0 Fax: +43 3577 757-182 E-Mail: info@at.atb-motors.com ATB TECHNOLOGIES GmbH Millennium Park 11, A-6890 Lustenau Phone: +43 5577 9010 - 0 Fax: +43 5577 9010 - 110 E-Mail: info@at.atb-motors.com
ATB LAURENCE SCOTT LTD. PO Box 25 Hardy Road, NR1 1JD Norwich, Norfolk Phone: +44 1603 628 333 Fax: +44 1603 619 788 E-Mail: admin@laurence-scott.com
Serbia ATB SEVER a.d. Magnetna polja 6, 24000 Subotica Phone: +381 24 548 111, 548 222 Fax: +381 24 546 893 E-Mail: sever@yu.atb-motors.com
Czech Republic Germany ATB ANTRIEBSTECHNIK GmbH Silcherstraße 74, D-73642 Welzheim Phone: +49 7182 14 - 1 Fax: +49 7182 14 - 590 E-Mail: info@de.atb-motors.com ATB MOTORENTECHNIK GmbH Helgoländer Damm 75, D-26954 Nordenham Phone: +49 4731 365 0 Fax: +49 4731 365 159 E-Mail: nordenham@de.atb-motors.com
France ATB SELNI SAS 6 rue Louise Michel BP 24, F-58028 Nevers Cedex Phone: +33 3 86 93 42 00 Fax: +33 3 86 93 42 22 E-Mail: info@fr.atb-motors.com
ATB COMPONENTS S.R.O. Lihovarská 1335/9, CZ-71610 Ostrava - Radvanice Phone: +420 5 962 333 40 Fax: +420 5 962 333 40 E-Mail: atb.bastro@quick.cz
China ATB MOTORS (SHANGHAI) Co. Ltd. Section E, Floor 1, Building 28, No.500 East Fute 2nd Road, 200131 Shanghai Phone: +86 21 5046 1928 Fax: +86 21 5046 3362 E-Mail: info@cn.atb-motors.com
ATB SEVER a.d. Magnetna polja 6 24 000 Subotica Serbia Tel. +381 24 548-111, 548-222 Fax +381 24 546-893 www.atb-motors.com sever@yu.atb-motors.com