PERIPHERAL PUMPS AQUAMAT ANDAUTOMATIC PUMPS HIDROPAK

Page 1

Technical Documentation

HP07EN

PERIPHERAL PUMPS AQUAMAT AND AUTOMATIC PUMPS HIDROPAK


Vision

We set your ideas in motion. We do not merely manufacture motors, but instead turn the ambitious concepts of our customers into modern, innovative and reliable products, which are unique and point the way to the future. We bring our customers closer to their goals with reliability, creativity and flexibility.

Business Units

Home Appliances

Serial Motors

New Businesses

Project Motors


Peripheral pumps AQUAMAT 1

Description, design and technical data

Materials of the pump parts: - Pump housing: gray iron - Motor housing: Al alloy - Shaft: stainless steel - Impeller: copper alloy Technical data - Flow: up to 85 l/min - Head: up to 70 m - Suction pressure: max 3 bar - Discharge pressure: max 10 bar - Water temperature: up to 50oC At the greatest head, the pump AQUAMAT absorbs the greatest power. For this reason the usage of the pump is allowed within the limits of the flow and the head designated on diagrams.

Pump designation

A - 9 8 9

T M T

Basic type Characteristics of pump size Single-phase or three-phase motor

Application Automatic pumps AQUAMAT are applied for supplying households, cottages, motels, farms with cold consumption water and they also can be used for irrigation. They pump water out of dug, drilled or driven wells, cisterns, tanks and brooks. Transported liquid Pump is used for transport of cold consumption water with allowed quantity of sand max 25 g/m3 and the greatest diameter of particles up to 0,04mm.

Design Pump is peripheral, single-stage, in monoblock execution with electric motor. Loose radial coupling of shaft and impeller enables seflpositioning of impeller in pump housing. Pump housing sealing is done by mechanical seal. At suction and discharge there are flanges with inner tube thread R1 1/4 ", which are intended for connection to the pipeline. This enables easy and simple mounting and dismounting of pump. The main parts of the pump are of high quality and assure long life practically without maintenance.

Electric motor data - Two pole single-phase or three-phase asynchronous motor - Rated voltage: 1x230V or 3x400V, 50Hz - Degree of mechanical protection: IP54 - Insulation class: F - Allowed ambient temperature: 40oC - Protection: pumps are delivered with motor without protection, so it is necessary to carry out the protection with motor protection switch

Standards and marks of quality Pumps AQUAMAT are in category of domestic appliances. They hold all necessary certificates and declarations in accordance with the directives of the European Union. According to the EU legislation, they carry the CE sign. They are attested by TĂœV Rheinland. Pumps meet the requirements of the following standards: - EN 60335-1 - EN 60335-2-41 - EN 55014-1 - EN 55014-2


Peripheral pumps AQUAMAT Diagrams of hydraulic characteristics

Diagrams of hydraulic characteristics J/kg

H m

HMAX

70

600

3,0

50

500

2,5

400

2,0

HMAX

30

300

9

A-

20

200

A-

9

1,5

A-8

1,0

QMAX

8

INPUT POWER

60

A-

HEAD

P1 kW

700

40

10

100

0

20

10

0

30

40

60

70

80

90

0

Q, l/min 3

Q, m /h

5

4

3

2

1

50

0,5

20

10

30

40

50

60

70

80

90 5

4

3

2

1

0

Q, l/min 3

Q, m /h

FLOW

FLOW

h

pS bar

% 100

10 9

80

8

STATIC PRESSURE p S*

90 70

EFFICIENCY

2

60

A-9

50

A-8

40 30 20 10 0

7 6

9

5

A-

A-8

4 3 2 1 0

0

20

10

0

1

30

40

50 3

2

60

70

80

90 5

4

Q, l/min

100

110

120

130

140

150

160

170

Q, m /h

*static pressure in the pump housing at the starting instant.

FLOW

The characteristics are valid for Hu=0 m, without resistance in the discharge pipe, for nominal voltage and up to 1000m above sea level.

Max suction head Type

Hu

180

STARTING VOLTAGE UZ

3

Flow Q, l/min 20

30

40

m

50 60 Head H, m

70

80

85

A-8 M(T)

7

38

30

20

10

0

A-9 M(T)

7,5

70

60

50

40

30

20

10

5

Note: All rights to change or complete the data preserved. Obligatory data are given on special request.

190 UZ, V


Peripheral pumps AQUAMAT 3

Measurement drawing, electrical characteristics and masses

Measurement drawing

D

96 20

H

HE

H1

H2

D

20

Suction port

44

Port for watering

Discharge port

AA

10

HA

40 B

C

A

BB

AB

L1

A1

Dimensions, electrical characteristics and masses

Type

Rated voltage U V

Output power* P2 kW

Allowed no. of starting per hour

A

A1

AA

AB

B

BB

C

H

H1

H2 HA HE

L1

D

Mass kg

mm " 4

16,0

A-8 M

230

0,75

40

125 178,5 38 155 100 130

107

80 191

60

9

190

335

R1 1 /

A-8 T

400

0,75

50

125 178,5 38 155 100 130

107

80 191

60

9

190

335

R1 1 /4 "

14,0

A-9 M

230

1,5

20

140

89

90 206

65 12 211

392

R1 1 /4 "

21,5

362

R1 1 /

"

16,5

A-9 T

400

1,5

30

140

191 191

40 180 125 155 40 180 100 130

* Output power of electric motor

Note: All rights to change or complete the data preserved. Obligatory data are given on special request.

89

90 206

65 12 211

4


Automatic pumps HIDROPAK 4

Designation, design and technical data

Design Pump is peripheral, single-stage in monoblock execution with electric motor, pressure tank and pressure switch which enables automatic pump operation. Pressure gauge serves only for running control. There are standard executions with single-phase and three-phase asynchronous electric motors. Materials of pump parts - Pump housing: gray iron - Motor housing: Al alloy - Shaft: stainless steel - Impeller: copper alloy Technical data - Standard measures of connectors: suction: R 1 1/4" discharge: R 1" - Flow: up to 70 l/min - Head: up to 45 m - Working pressure range : 1-4,5 bar - Suction height: up to 30 m - Water temperature: up to 50oC

Pump designation

H - 9

T

8 9

M T

INJ 4"

Basic type Characteristic of pump size Single-phase or three-phase motor Designation for injector* Note: *Only for pumps with injector.

Application Automatic pumps HIDROPAK are applied for supplying households, cottages, motels, farms with cold consumption water and they also can be used for irrigation. They pump water out of dug, drilled or driven wells with depth level up to 7,5 m. Pump with injector can pump water out from a depth level up to 30 m. Transported liquid Pump is used for transport of cold consumption water with allowed quantity of sand max 25 g/m3 and the greatest diameter of particles up to 0,04 mm.

Electric motor data - Two pole single-phase or three-phase asynchronous motor - Rated voltage: 1x230V, 50Hz or 3x400V, 50Hz - Degree of mechanical protection: IP54 - Insulation class: F - Protection: pumps are delivered with motor without protection, so it is necessary to carry out the protection with motor protection switch Standards and marks of quality Pumps HIDROPAK are in category of domestic appliances. They hold all necessary certificates and declarations in accordance with the directives of the European Union. According to the EU legislation, they carry the CE sign. They are attested by TĂœV Rheinland. Pumps meet the requirements of the following standards: - EN 60335-1 - EN 60335-2-41 - EN 55014-1 - EN 55014-2


Automatic pumps HIDROPAK 5

Installation

Pump installation in case of shallow wells Pumps are used for water level depth up to 7,5 m. For ground-floor or one-floor households, weekend houses, for water consumption up to 50 l/min, we recommend type H-8 M(T). For water consumption up to 70 l/min, we recommend type H-9 M(T), for larger households, small motels, etc. Note When distance between pump and well increases, suction height decreases for 1 m on every 10 m. This should be considered while determining the position of the pump. For very remote wells the pump has to be placed beside the well or an injector has to be used with increasing the diameter of the suction pipeline.

Straight-trough tap

"T" tap joint up to

1

Suction pipe 1 /4" (32mm) Well pipe

1

Non return valve 1 /4"

Suction pipe 1 from 1 /4" (32mm)

Suction basket with valve

up to

Pump installation in case of deep wells

up to Straight-trough tap 0,8 m

For water level depth up to 30 m and consumption up to 30 l/min, we recommend type H-9 M(T) INJ 4" (for larger households, small motels, small farms, etc). *When suction height is less then 30 m, pump can be placed on a distance more than 10 m from the well. Every decrease of suction height for 1 m allows increase of distance between pump and well for 10 m, but not more than 50 m.

Main well pipe 4" (100 mm) Suction pipe 11/4" (32 mm)

C

min 1,5 m

Recirculating pipe 1" (25 mm)

Note: All rights to change or complete the data preserved. Obligatory data are given on special request.


Automatic pumps HIDROPAK Measurement drawing and pump characteristics

Recirculating port

Measurement drawing PUMP Pressure gauge

Port for watering

INJECTOR FOR 4" WELLS

R1"

Discharge port

1

250

R1 /4"

380

R1"

R11/4"

Pressure switch

98

C

Suction port

Pump with electric motor

50

725

160

13 46

240

Suction pipe R11/4"

Recirculating pipe R1"

50

160

96

64

A

B

6

Dimensions, electrical characteristics and masses

Type

Nominal voltage U V

Output power P2 kW

A

B

C

Mass

mm

mm

mm

kg

H-8 M

230

0,75

390

490

540

26

H-8 T

400

0,75

390

490

540

26

H-9 M

230

1,1

400

500

550

28,5

H-9 T

400

1,1

400

500

550

26,5

Pump characteristics with injector for deep wells Type

suction height

2

4

6

8

10

12

45 -

35 45 -

20 35 -

0 25 40 -

15 35 40 -

5 27 36 -

Hu

H-9 T(M) INJ 4"

30 25 20 15 10

Flow Q, l/min 14 16 18 Head H, m 20 10 0 30 24 17 40 36 30

20

22

24

26

28

30

10 25

0 20

15

10

5

0

Pump characteristics for shallow wells

Flow Q, l/min Type

40

45

50

60

70

80

Head H, m H-8 T(M)

30

25

20

10

0

-

H-9 T(M)

-

45

40

30

20

10

1)

QH data are valid for altitude up to 1000m above sea level. Pump characteristics for shallow wells are for a suction height Hu=0 m.

Note: All rights to change or complete the data preserved. Obligatory data are given on special request.


ATB Group - a global player a company of A-TEC INDUSTRIES AG


Company locations Austria

Great Britain

Head office

ATB MORLEY Ltd. Bradford Road, West Yorkshire, LS28 6QA Leeds Phone: +44 113 257 1734 Fax: +44 113 257 0751 E-Mail: sales@uk.atb-motors.com

ATB AUSTRIA ANTRIEBSTECHNIK AG Hohenstaufengasse 7, 1010 Vienna Phone: +43 1 90250-0 Fax: +43 1 90250-110 E-Mail: info@atb-motors.com Http://www.atb-motors.com ATB MOTORENWERKE GmbH G.-Bauknecht-Straße 1, A-8724 Spielberg Phone: +43 3577 757-0 Fax: +43 3577 757-182 E-Mail: info@at.atb-motors.com ATB TECHNOLOGIES GmbH Millennium Park 11, A-6890 Lustenau Phone: +43 5577 9010 - 0 Fax: +43 5577 9010 - 110 E-Mail: info@at.atb-motors.com

ATB LAURENCE SCOTT LTD. PO Box 25 Hardy Road, NR1 1JD Norwich, Norfolk Phone: +44 1603 628 333 Fax: +44 1603 619 788 E-Mail: admin@laurence-scott.com

Serbia ATB SEVER a.d. Magnetna polja 6, 24000 Subotica Phone: +381 24 548 111, 548 222 Fax: +381 24 546 893 E-Mail: sever@yu.atb-motors.com

Czech Republic Germany ATB ANTRIEBSTECHNIK GmbH Silcherstraße 74, D-73642 Welzheim Phone: +49 7182 14 - 1 Fax: +49 7182 14 - 590 E-Mail: info@de.atb-motors.com ATB MOTORENTECHNIK GmbH Helgoländer Damm 75, D-26954 Nordenham Phone: +49 4731 365 0 Fax: +49 4731 365 159 E-Mail: nordenham@de.atb-motors.com

France ATB SELNI SAS 6 rue Louise Michel BP 24, F-58028 Nevers Cedex Phone: +33 3 86 93 42 00 Fax: +33 3 86 93 42 22 E-Mail: info@fr.atb-motors.com

ATB COMPONENTS S.R.O. Lihovarská 1335/9, CZ-71610 Ostrava - Radvanice Phone: +420 5 962 333 40 Fax: +420 5 962 333 40 E-Mail: atb.bastro@quick.cz

China ATB MOTORS (SHANGHAI) Co. Ltd. Section E, Floor 1, Building 28, No.500 East Fute 2nd Road, 200131 Shanghai Phone: +86 21 5046 1928 Fax: +86 21 5046 3362 E-Mail: info@cn.atb-motors.com


ATB SEVER a.d. Magnetna polja 6 24 000 Subotica Serbia Tel. +381 24 548-111, 548-222 Fax +381 24 546-893 www.atb-motors.com sever@yu.atb-motors.com


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.