Scope of Work
Mittal Bhavana
Submittal documents for deferred submittal items shall be submitted to the registered design professional in responsible charge, who shall review Tenant improvement of Suite C2 at 9625 Mission Gorge rd, Santee, CA 92071. Previously Nutrition Zone. All existing them and forward them to the building official with a buildings to remain. No existing building to be demolished. notation indicating that the deferred submittal documents have been reviewed and that they have No proposed future building . Existing unisex toilet is ADA been found to be in general conformance with the complaint. Mechanical HVAC unit on roof top, will not be design of the building. The deferred submittal items altered. Existing sprinkler system, will not be altered. All shall NOT be installed until their design and submittal electrical is existing and not altered. documents have been approved by the building official.
Design & Planning 13892 Dodder Ct, Poway, CA 92064 EXISTING BUILDING TO REMAIN
EXISTING BUILDING TO REMAIN EXISTING PARKING
EXISTING BUILDING TO REMAIN EXISTING PARKING
114b 5a
EXISTING PARKING
WH A10
14.
15. 16. 17.
18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34.
35. 36. 37. 38. 39. 40. 41. 42. 43. 44. 45. 46. 47. 48.
49.
EXISTING PARKING
EXISTING PARKING
EXISTING PARKING
PATH OF EGRESS TRAVEL TO PUBLIC WAY
Path of Egress travel to public way
Vicinity Map Room name 150 SF
Room Tag
101
Door Tag
Accessible parking spaces are provided on the shortest possible route to the accessible entrance.
N
Sheet List Sheet Number
NT FRO OF G DIN BUIL
2 EXISTING DISABLED ACCESS PARKING SPACE
ACCESSIBLE CURB RAMP
3"
13.
EXISTING PARKING
2 6 '-
12.
EXISTING BUILDING TO REMAIN
SITE LOCATION OF THE TENANT IMPROVEMENT UNDER THIS PERMIT PREVIOUSLY NUTRITION ZONE
ACCESSIBLE CURB RAMP
71'-10"
EXISTING BUILDING TO REMAIN
18' -4"
1
EXISTING BUILDING TO REMAIN
Sheet Name EXISTING PARKING
Equipment Tag
888
North Arrow 1 Ref 1
A101
1
Interior Elevation Tag
1 Ref
1
A1 A2 A5 A6 A7 A8 A3 A4 A9
SIM Section Tag
A101
A10
26'-3"
11.
Deli Belly
10.
EXISTING PARKING
Cover Sheet/Site Plan Equipment Specs Floor Plans Reflected Ceiling Plan Plumbing & Electrical ADA Standards ADA Standards Equipment Specs 2 Equipment Specs 3 Best Management Practices Plan Interior Elevations & Equipment
EXISTING BUILDING TO REMAIN BAC
KO
IN G UILD FB
EXISTING TRASH ENCLOSURE TO REMAIN
No. 1 Revision 1
Symbol Legend 1/4" = 1'-0" 0
Site Plan 1" = 50'-0"
N
All property lines, easements and buildings, existing and proposed, are shown on this site plan.
3 2 1
Code Analysis Project Data 2019 CALIFORNIA BUILDING CODE 2019 CALIFORNIA MECHANICAL CODE 2019 CALIFORNIA PLUMBING CODE 2019 CALIFORNIA ELECTRICAL CODE 2019 CALIFORNIA FIRE CODE 2010 AMERICAN DISABILITY ACT STANDARDS
Use Group The use group shall be classified as followsUse group A - Assembly without fixed seating General Building Limitations Type of construction - V-B Height limitation - No change Allowable floor area for one story building Building square foot totals Total building gross area = 1500 SF
Water Information Padre Dam Municipal Water District 9300 Fanita Pkwy Santee, CA 92071
EXIT ANALYSIS- OCCUPANT LOAD CALCULATIONS MAX. FLOOR AREA ALLOWANCES OCCUPANCY TYPE
OCCUPANT LOAD FACTOR
SF
Seating
Assembly without fixed seats unconcentrated (tables & chairs) Assembly without fixed seats standing space
15 Net
544
37
5 Net
28
6
Waiting
NO. OF OCCUPANTS
Food Prep
Kitchen
200 Gross
340
2
Food Assembly
Kitchen
200 Gross
179
1
Office
Business
36
1
Janitor's Closet
Unoccupied space
100 NR
28
NR
Toilet Corridor
Unoccupied space Unoccupied space
NR
50 74
NR
NR
Total Occupants
NR 47
Occupant load One story building = 47 occupants (1 Exit ) Maximum common path of Egress travel distance With sprinkler system = 75' max. Fire resistance ratings of structural elements (Type 5B construction for sprinklered buildings) Exterior walls Load bearing walls = 0 hrs non-load bearing walls = 0 hrs structural members supporting walls = 0 hrs Floor construction including beams = 0 hrs Description of Use - Food Service Sprinklers - Yes, Existing
5' -0"
Revision Set Revision Set Permit Set
Date Date 1
11-01-2021 8-25-2021 4-27-2021
9' -0"
NO PARKING
2 EXISTING DISABLED ACCESS PARKING SPACE LOADING / UNLOADING AREA
Facility Size Total 1500 Sq Ft.
ACCESSIBLE CURB RAMP WHEEL-STOP IF REQUIRED TO PREVENT ENCROACHMENT OVER REQUIRED WIDTH OF WALKWAY
Facility Type Restaurant Single service disposable utensils No alcoholic beverage service
48" WIDE RAMP, SLOPED AT 8.3% MAX
2% MAX CROSS SLOPE
Business Owner
Deli Belly
SIDE FLARES SLOPED AT 10% MAX RAMP SURFACE TO BE CONTRASTING FINISH FROM ADJACENT WALK
SIDEWALK
4' -0" MIN
Disabled Parking 1" = 10'-0"
Samir Hanoosh (619) 839-5777 samhannosh@gmail.com
1
Mr. Robert Bahri 1554 Plantation Way El Cajon, CA 92019 (619) 839-5777
1. Accessible parking spaces are provided on the shortest possible route to the accessible entrance.
Designer Bhavana Mittal Mittal Design & Planning 13892 Dodder Ct Poway, CA 92064 (650) 918-9889 bhavanamittal21@gmail.com
Description
23' -0" 9' -0"
Facility Name and Address Deli Belly 9625 Mission Gorge Rd, Suite C2 Santee, CA 92071
Maximum floor area allowance per occupant No. of employees Assembly Area without fixed seats-unconcentrated = 15 Net 5 employees Assembly Area without fixed seats-standing space = 5 Net
ROOM
EXISTING PARKING
18'-0"
9.
EXISTING PARKING
MIN
8.
EXISTING PARKING
4' -0 "
7.
EXISTING PARKING
48'-11"
6.
Ref
5.
FOOD FACILITY IS SERVED BY COUNTY OF SAN DIEGO. MUNICIPAL SEWAR IS SERVED BY COUNTY OF SAN DIEGO. ALL EXTERIOR DOORS OPEN OUTWARDS AND ARE SELF CLOSING. IF DOORS CANNOT OPEN OUTWARD, PROVIDE TIGHT FITTING SCREEN DOORS THAT OPEN OUTWARD AND ARE SELF CLOSING, OR PROVIDE AN AIR CURTAIN OVER THE DOOR THAT HAS A MINIMUM VELOCITY OF 750 FPM, MEASURED 3FT ABOVE THE GROUND. MIN. 10FT CANDLES OF LIGHT MEASURED 30 INCHES OFF FLOOR IS PROVIDED IN ALL STORAGE AREAS. THREE COMPARTMENT SINKS SHOULD BE ATLEAST 18"X18"X12" DEEP. SHALL BE STAINLESS STEEL WITH DUAL INTEGRALLY INSTALLED STAINLESS STEEL DRAINBOARDS MEETING CURRENT 'NSF' STANDARDS. WHEN INSTALLED NEXT TO A WALL, A METAL BACKSPLASH EXTENDING UP THE WALL AT LEAST 8 INCHES WILL BE REQUIRED. IT SHALL BE CONNECTED TO A FLOOR SINK WHICH CONNECTS TO A GREASE TRAP AND THEN CONNECTED TO THE SEWER. FOOD PREPARATION SINK SHALL BE A ONE COMPARTMENT SINK. IT SHALL DRAIN TO AN ADJACENTLY LOCATED FLOOR SINK VIA LEGAL AIR GAP. HAND WASH SINK SHALL BE PROVIDED IN FOOD PREPARATION AREAS AND SHALL HAVE HOT AND COLD RUNNING WATER WITHOUT THRU A MIXING TYPE FAUCET, WITH SOAP AND SANITARY TOWELS PROVIDED. INTERIOR TOILET DOORS ARE SELF CLOSING, TIGHT FITTING AND UNDERCUT (1") FOR MAKE-UP SUPPLY. ALL SINKS AND LAVATORIES ARE SUPPLIED WITH (100F - 108F) HOT AND COLD RUNNING WATER UNDER PRESSURE. ALL LAVATORIES OR HAND WASH SINKS WILL HAVE A COMBINATION FAUCET OR PREMIXING FAUCET CAPABLE OF SUPPLYING WARM WATER FOR A MIN. OF 15 SECONDS WITHOUT REACTIVITY. FOOD AND UTENSIL SINKS ARE PROVIDED WITH WATER SAVER FAUCETS CAPABLE OF REACHING EACH COMPARTMENT. ALL FOOD PREPARATION COUNTERS AND SALAD BARS SHOULD BE PROTECTED BY "SNEEZE GAURDS" THAT COMPLY WITH EHP-885. TOILETS SHOULD SATISFY HANDICAP REQUIREMENTS, i.e. GRAB BARS, AND AMERICAN WITH DISABILITY ACT (ADA). HANDWASHING LAVATORIES SHALLBE PROVIDED WITHIN EACH TOILET ROOM, AND SHALLHAVE HOT AND COLD RUNNING WATER DISPENSED FROM A MIXING TYPE FAUCET, SOAP AND SINGLE SERVICE PAPER TOWELS SHALL BE DISPENSED FROM PERMANENTLY AFFIXED DISPENSERS MOUNTED ON THE NEAREST WALL ADJACENT TO THE HANDSINK. ALL EQUIPMENT GIVING OFF WASTE OR CONDENSATE ARE REQUIRED TO DRAIN INTO FLOOR SINK WITH LEGAL AIR GAP. ALL EQUIPMENT ARE 'NSF'. JANITORIAL SINK SHALL BE SEPARATED FROM THE REST OF THE FOOD ESTABLISHMENT EQUIPMENT WITH 18" HORIZONTAL DISTANCE, OR BY A SOLID PARTITION. THE JANITORIAL SINK SHALL BE A CURBED AREA PROPERLY SLOPED TO A DRAIN. SINK SHALL BE SUPPLIED WITH HOT AND COLD RUNNING WATER TO A MIXING TYPE FAUCET. A CABINET WITH A MOP AND BROOM RACK TO BE PROVIDED FOR THE STORAGE OF THE CLEANING EQUIPMENT AND SUPPLIES. SINK FAUCET SHALL BE PROTECTED WITH AN APPROVED BACK FLOW PREVENTION DEVICE. MOP SINK SHALL BE A MIN. 24" x 24" FLOOR MOUNTED TYPE OR CAN WASH AREA LARGE ENOUGH TO ACCOMODATE FLOOR MATS. MOP SINK FAUCET WILL HAVE A THREADED LIP FOR HOSE ATTACHMENT. NO CHEMICAL DISPENSING SYSTEMS OR VALVES SHALL BE ATTACHED TO THE MOP SINK FAUCET OUTLET. FLOOR DRAINS ARE REQUIRED IN JANITORIAL ROOMS WITH MOP SINKS. WATER-RESISTANT WALLS (CERAMIC TILE, FRP, STAINLESS STEEL) ARE REQUIRED BEHIND MOP SINKS, 8FT HIGH. ALL PLUMBING, ELECTRICAL AND GAS LINES SHALL BE CONCEALED WITHIN THE BUILDING STRUCTURE TO A GREAT EXTENT AS POSSIBLE. ALL LINES NOT CONCEALED, TO BE SECURED (6 INCHES) OFF THE FLOOR AND (3/4" FROM WALLS USING STANDOFF BRACKETS. FOOD SAFETY CERTIFICATE WILL BE REQUIRED BEFORE FINAL. WALK-IN REFRIGERATOR SHELVES SHALL ACCOMODATE SHALLOW FLAT PANS FOR QUICK REDUCTION OF HEAT (PANS SHALL NOT EXCEED 4" IN HEIGHT). SPACE BETWEEN SHELVING TO BE ATLEAST 8" HIGH. PAINT, TILE AND ALL OTHER FINISH MATERIAL USED ON WALLS AND CEILINGS OF KITCHEN, FOOD PREP, WORK AND STORAGE AREAS, WILL BE LIGHT COLOR, WHICH HAS A REFLECTIVE VALUE OF 70% OR GREATER. ALL AREAS OF FOOD FACILITY TO BE PROVIDED WITH MIN. (30 FT) CANDLES OF LIGHT MEASURED (30") OFF THE FLOOR DURING GENERAL CLEAN-UP ACTIVITIES. ALL CHEMICAL DISPENSING SYSTEMS TO BE INSTALLED DOWNSTREAM OF A PROPERLY INSTALLED AND TESTABLE BACKFLOW PREVENTION DEVICE OR AN AIR GAP. THE SYSTEM SHALL NOT BE DIRECTLY OR INDIRECTLY CONNECTED TO THE MOP SINK FAUCET OUTLET. FLOOR DRAINS ARE REQUIRED IN NEW TOILET ROOMS. AN APPROVED REDUCED PRESSURE BACKFLOW PREVENTION DEVICE SHALL PROTECT WATER SUPPLY TO CARBONATORS. THE RELIEF VALVE SHALL DRAIN INDIRECTLY TO THE SEWER WITH A LEGAL AIR GAP. CONCRETE SEALER TO BE USDA APPROVED FOR ACID AND GREASE RESISTANCE. IF 'SLIMFOOT' CERAMIC TILE IS USED, A SAMPLE TO BE SUBMITTED TO THE ENVIRONMENTAL HEALTH PRIOR TO INSTALLATION. ALL FOOD RELATED AND UTENCIL RELATED EQUIPMENT SHALL MEET OR BE EQUIVALENT TO SANITATION STANDARDS BY AN AMERICAN NATIONAL INSTITUTE (ANSI) ACCREDITED PROGRAM. VENTS ARE PROVIDED FOR ALL PLUMBING FIXTURES. NO PLUMBING FIXTURES, I.E. FLOOR SINK, FLOOR DRAIN TO BE INSTALLED INSIDE WALK-IN COOLERS OR FREEZERS. FOR DELIVERY DOORS (4 FT) IN WIDTH OR LESS, THE AIR CURTAIN MUST PRODUCE A VELOCITY OF NOT LESS THAN (750 FT/MIN) ACROSS THE ENTIRE OPENING, AS MEASURED AT A POINT (3 FT) ABOVE THE FLOOR. FOR WIDER DOORS, THE VELOCITY IS (1600 FT/MIN) ACROSS THE ENTIRE OPENING. THE FAN MUST ACTIVATE VIA A MICROSWITCH. EXHAUST A MIN 12 AIR CHANGES PER HOUR VENTILATION TO ALL JANITOR CLOSETS WITH MOP SINKS. SHATTER SHIELDS ARE PROVIDED FOR ALL LIGHTS ABOVE FOOD PREPERATION AREAS. ALL INTERIOR FINISHES TO COMPLY WITH CHAPTER 42 OF UBC. ALL EXITS ARE OPENABLE FROM INSIDE WITHOUT USE OF KEY. ESTABLISHMENTS WITH FLOOR MATS TO CLEAN, MUST HAVE A FLOOR MOUNTED TYPE OF MOP SINK OR CAN WASH AREA. IF SOFT DRINKS, ICE OR OTHER DISPENSERS ARE SELF SERVICE, OR IF REFILLS ARE GIVEN, THEN IT MUST BE A PUSH BUTTON TYPE. PLUMBING ELECTRICAL AND GAS LINES CANNOT CROSS TRAFFIC AREAS. SHELVING OVER WET AREAS (SINKS) SHALL BE METAL. AT LEAST (96) LINEAL FEET, MIN (18") WIDE, APPROVED SHELVING UNITS ARE REQUIRED FOR BACKUP DRY STORAGE SPACE. CONCRETE SLAB IS PROVIDED FOR TRASH ENCLOSURES. AREA IS ENCLOSED BY WALLS AND THE INTERIOR WALL SURFACES ARE SMOOTH SEALED AND WASHABLE. THE MATERIALS AND COLOR ARE ARCHITECTURALLY INTEGRATED WITH THE DESIGN OF THE BUILDING. AN APPROVED BACKFLOW PREVENTER SHALL BE PROPERLY INSTALLED UPSTREAM OF ANY POTENTIAL HAZARD BETWEEN THE POTABLE WATER AND A SOURCE OF CONTAMINATION. ALL FLOORS TO SLOPE 1/4 IN PER FT. TO THE NEW FLOOR DRAINS. SNEEZE GAURDS, IF REQUIRED AND INSTALLED, SHALL COMPLY WITH EHP-885 REQUIRMENTS. NO PRESSED OR PLYWOOD SHELVING IS ALLOWED UNLESS COMPLETELY ENCASED, IN DRY STORAGE AREA CLEAN-IN-PLACE" EQUIPMENT WHICH IS TOO LARGE TO FIT INTO A UTENSIL WASH SINK, OR WHICH IS FIXED IN PLACE, I. E. SPIRAL MIXERS, MIXERS WITH NON-REMOVABLE BOWLS, AND SIMILIAR EQUIPMENT THAT MUST BE CLEANED AND SANITIZED IN-PLACE, MUST BE PROVIDED WITH AN ADJACENT FILL FAUCET EQUIPED WITH HOT AND COLD RUNNING WATER UNDER PRESSURE AND ADJACENT FLOOR SINK OR TROUGH TO RECIEVE THE WASTE WATER FROM THE CLEANING AND SANITIZING PROCCESES. OVERHEAD CURTAINS ARE TO BE PROVIDED OVER CARGO, DEDICATED DELIVERY DOORS AND DOORS OPENING INTO FOOD PREP AREAS.
Ref
1. 2. 3. 4.
124c
2. The maximum slope of the parking surface at the accessible space and adjacent access aisle, in any direction, is ≤ 1:48 3. The accessible parking spaces are to be identified by a reflectorized sign, permanently posted immediately adjacent to and visible from each space, consisting of a profile view of a wheelchair with occupant in white on dark blue background. The sign shall ≥70 in.² in area.
Santee Cover Sheet/Site Plan 001 11-01-2021 Mitt B Mitt B
Project number Date Drawn by Checked by
A1 Scale
As indicated
10/31/2021 10:47:47 PM
Health Notes
10
9625 Mission Gorge Rd, Suite C Santee, CA 92071
EXISTING PARKING
EXISTING PARKING