OSBY HVTS-G Biomass boiler for moist fuels, 1-7MW The Professional´s choice since 1935
Highly efficient, complete solution With our new boiler for firing moist fuels we can offer turnkey boiler rooms for wood chips.
Turnkey, reliable unit that meets all requirements regarding efficiency, accessabillity and easy operation. Beneficial for both environment and operation economy.
The HVTS-G is a complete unit with a grate design that allows the combustion air to be distributed in different zones. Automatic ash handling with an ash scraper integrated under the grate cart and internal ash- and dust augers means that the maintenance can be kept at a minimal. The brick lined furnace and the ceramic after burner vault make sure that the combustion temperature is at the desired level before the flue gases leaves the furnace, which is the key to a clean combustion process. The distribution of combustion air is handled by primary-, secondary- and tertiary air fans which adds the air through holes in the grate and through nozzles in the combustion chamber. The primary air is distributed in different zones with throttle regulation to facilitate operating at low loads. The air distribution is adapted considering fuel kind and fuel moisture count. The HVTS-G is also equipped with flue gas recirculation. The flue gas canals have been designed so that the dust particles will fall down to the bottom of the boiler and can be transported out by the interal augers together with ash and cinder. The boiler can of course be equipped with different types of flue gas cleaning and external automatic discharge of ash and dust.
For more information on boilers in the Osby Parca product range, please visit www.osbyparca.se
Automatic operation The fuel is being fed into the furnace through the front of the boiler. The combustion takes place on a stepped grate which pushes the fuel forward while drying and burning it. The ash and the dust is being handled automatically by internal scrapers and augers.
Design data HVTS-G
The HVTS-G is equipped with compressed air cleaning. Our control system can be programmed to handle the total facility including silos, pumps and back-up boilers.
Output
1 - 7MW
Design pressure
6 bar
Design temperature
110 - 165ツーC
Flue gas temperature
<200ツーC
Fuel moisture
35 - 50%
Boiler efficiency
90%
2010-11-29. All rights reserved. Information subject to change without notice.
Technical data HVTS-G Dimensions, mm
Furnace, mm
Output 50% moist
Gasresistance
L
B
H
H1
I
b
h
Water volume
1000 kW
750 Pa
4910
1810
3430
3030
2900
1350
2800
4000 L
1500 kW
950 Pa
4910
2080
3580
3080
2900
1620
2850
6500 L
2000 kW
950 Pa
6050
2270
3690
3190
3700
1790
2930
9000 L
3000 kW
950 Pa
6510
2440
3990
3390
3700
1980
3130
13000 L
4000 kW
950 Pa
7405
2760
3990
3390
4500
2300
3130
17500 L
5000 kW
950 Pa
7740
3230
4230
3630
4500
2700
3330
22000 L
6000 kW
950 Pa
8910
3230
4230
3630
5300
2700
3330
23000 L
7000 kW
950 Pa
9280
3230
4230
3630
5300
2700
3330
23500 L