Mackwell Xylux LR6

Page 1

08/13

LR6 Data Sheet

High Performance - 10.8 Lux LED Luminaire

XYLUX LR6 – 10.8 Lux High Ceiling The XYLUX LR6 is a non maintained LED emergency luminaire; designed to achieve 10.8Lux at up to 6 meters mounting height. The lamphead comes complete with articulated control-gear. Application The LR6 complies with the US emergency specification of 1-foot candle lux levels. This is a requirement in many international projects. The distribution from the LR6 makes it suitable for interior high ceiling final exit applications. The integrated reflector and optic design maximises performance whilst complying to the 10.8 lux requirements

High Performance LED luminaire 10.8 Lux at 6mtr ceiling height       

Optical lens configuration for 10.8 lux (1 Foot Candle) High Ceiling applications 1 x 3w High Power High Power LED Articulated control gear fits through 42mm-44mm ceiling hole size 3 year warranty Smart Charge technology to reduce energy consumption Available with DALI functionality Designed & manufactured in the UK

The lamphead includes a Bi-Colour LED charge indicator, 500mm wiring loom and recessed mounting brackets. The XYLUX LR6 is part of the new generation of XYLUX LED Emergency luminaires designed to be effective and unobtrusive. Technology Options  3hr Standard  10.8 Lux  mackwell AutoTest  DALI


High Performance 10.8Lux LED Luminaire

XYLUX LR6 – 10.8 Lux High Ceiling PRODUCT DETAILS Specification

Relevant Standards

Supply Voltage: 230Vac ± 10% 50/60 Hz Supply Current: 30mA max Ambient Temperature: 0°C to +35°C Max Case Temp (Tc): 70°C Conductor size: 0.5 – 1.5mm2 Weight of Control Gear: 240g (incl. battery) Weight of Lamp Head: 80g IP Rating of Luminaire IP30 Emergency Duration: 3 hours Lumen Output: 160 lumens nominal Charge Indicator: Green/Red bi-colour LED

EN 61347-2-7 Lamp control gear EN 61347-2-13 LED control gear EN 60598-2-22 Luminaire BS 5266-1:2005/IEC62034 Automatic Testing IEC 62386 DALI

Technology  

Batteries The luminaire includes a rechargeable 3.6V 2.2Ah NiMH battery pack for 3 hour emergency operation. REVERSING BATTERY POLARITY WILL CAUSE PERMANENT DAMAGE TO THE CONTROL GEAR.

Photometric Information Available from our website at www.mackwell.com

mackwell AutoTest® technology provides the user with self-contained automatic testing in compliance to IEC62034 Potential Free Contact option allows basic onsite monitoring of Emergency lighting luminaire status. DALI Emergency options give further benefits to the user enabling the testing and monitoring of the emergency lighting system on site or via the internet.

Please note that for non-DALI AutoTest® products, the start times for the tests are set automatically to ensure random testing of the units at times of minimum risk. As a consequence tests may occur at any time, and caution should be exercised in situations where this might be inconvenient.

We reserve the right to alter specifications without prior notice.