1 minute read
TECHNICAL DRAWINGS
Cross Section B-B Scale 1:25
80x320mm concrete coping with 40mm overhang fixed to 110x75x220mm masonary brick wall (outer skin facebrick)
Advertisement
40mm mulch plants fixed in 150mm planting soil layer fixed on geotextile filter fabric fixed on 8mm dimple sheet fixed on geotextile filter fabric fixed on fixed on 25x1200mm isoboard closed cell insulation fixed on Perma SEAL 20P Green roof drainage layer on Perma SEAL root barrier fixed on Bituminious waterproofing membrane torched applied on 50mm screed to fall 1:60 casted on Concrete waffle floor slab full bore corner outlet drainage connected to 75mm diameter stormwater downpipe
Section detail 1: Flat roof level
Scale 1:5
710x2200mm aluminum glazing system with 122mm mullions and transoms
12.38mm laminated double glazing with thermal break
300x300mm RC column concealed by 50mm cavity infill between 110x75x220mm facebrick wall cladding fixed to RC slab with steel shelf angle
81mm overall thickness of sprung sports hall hardwood flooring fixed on 50mm screed casted on 500mm RC waffle floor slab
Exterior Interior
3500mm slab-to-slab aluminum storefront glazing system with 122mm mullions and transoms
1100mm CTC distance
12.38mm laminated double glazing with thermal break 420x460mm bolted onto ground floor beam
Movement joint
30mm polished screed casted on 150mm reinforced concrete floor slab casted on 50x1200mm isoboard closed cell insulation boards on 250 micron DPM layed on 50mm sand blinding layed on 150mm layers of compacted earth fill (containing little to no organic and clay material) sealant and movement joint with weep holes to allow for head flashing drainage steel shelf angle and continuous metal shelf angle flashing integrated with wall waterproofing
Section detail 2: Middle floor level
Scale 1:5
Section detail 3: Ground floor level Scale 1:5