1 minute read

TECHNICAL DRAWINGS

Cross Section B-B Scale 1:25

80x320mm concrete coping with 40mm overhang fixed to 110x75x220mm masonary brick wall (outer skin facebrick)

Advertisement

40mm mulch plants fixed in 150mm planting soil layer fixed on geotextile filter fabric fixed on 8mm dimple sheet fixed on geotextile filter fabric fixed on fixed on 25x1200mm isoboard closed cell insulation fixed on Perma SEAL 20P Green roof drainage layer on Perma SEAL root barrier fixed on Bituminious waterproofing membrane torched applied on 50mm screed to fall 1:60 casted on Concrete waffle floor slab full bore corner outlet drainage connected to 75mm diameter stormwater downpipe

Section detail 1: Flat roof level

Scale 1:5

710x2200mm aluminum glazing system with 122mm mullions and transoms

12.38mm laminated double glazing with thermal break

300x300mm RC column concealed by 50mm cavity infill between 110x75x220mm facebrick wall cladding fixed to RC slab with steel shelf angle

81mm overall thickness of sprung sports hall hardwood flooring fixed on 50mm screed casted on 500mm RC waffle floor slab

Exterior Interior

3500mm slab-to-slab aluminum storefront glazing system with 122mm mullions and transoms

1100mm CTC distance

12.38mm laminated double glazing with thermal break 420x460mm bolted onto ground floor beam

Movement joint

30mm polished screed casted on 150mm reinforced concrete floor slab casted on 50x1200mm isoboard closed cell insulation boards on 250 micron DPM layed on 50mm sand blinding layed on 150mm layers of compacted earth fill (containing little to no organic and clay material) sealant and movement joint with weep holes to allow for head flashing drainage steel shelf angle and continuous metal shelf angle flashing integrated with wall waterproofing

Section detail 2: Middle floor level

Scale 1:5

Section detail 3: Ground floor level Scale 1:5