Light Green International Co.Ltd
Page 1 Of 12
LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:230.2V I:0.2310A P:26.70W PF:0.5010
Lamp Flux:1454.34x1 lm
NAME: LED Panel Light
TYPE:cool white
DIM.:
SPEC.:
MFR.: Light-green
SUR.:0.262m*0.563m
DATA OF LAMP
PHOTOMETRIC DATA
LGI-C0306WDA-Q
MODEL
WEIGHT:1.5KG
Eff: 54.47 lm/W
Imax(cd)
505.2
S/MH(C0/180)
1.26
NOMINAL POWER(W)
28
LOR(%)
100.0
S/MH(C90/270)
1.34
RATED VOLTAGE(V)
230
TOTAL FLUX(lm)
1454.3
η UP,DN(C0-180)
0.0,51.6
NOMINAL FLUX(lm)
1454.34
CIE CLASS
DIRECT
η UP,DN(C180-360)
0.0,48.4
LAMPS INSIDE
1
η up(%)
0.0
CIBSE SHR NOM
1.25
TEST VOLTAGE(V)
230.2
η down(%)
100.0
CIBSE SHR MAX
1.35
LUMINOUS INTENSITY DISTRIBUTION DIAGRAM
C0 PLANE ISOLUX DIAGRAM (UNIT:lx) MH(m) 14 18
-/+180 -150
150
22 -120
120
26 30
-90
0
90
110
38
220 -60
330 440
34
42 60 UNIT:cd C90/270,115.3°
30 550 0 AVERAGE BEAM ANGLE(50%):115.3 DEG
46
-30
0.0
17.0 3.00 2.50 2.00 1.50 1.00
AAAAAAAAAAAAAAAAAAAAAAAAAAA
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:25.6DEG Operators:王 林 飞 Test Date:2010-11-12
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
34.0 S(m) 0.5100 0.4000 0.2500 0.2000 0.1500
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:60% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 2 Of 12
ZONAL FLUX DIAGRAM AND LUMINANCE LIMITATION CURVES
ZONAL FLUX DIAGRAM: γ
C0 502.9 496.7 486.5 471.8 452.6 428.6 400.0 367.5 331.4 292.8 252.3 210.8 168.5 126.1 84.57 45.69 13.27 1.485
5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 DEG
C45 503.8 499.7 492.4 480.8 465.2 444.5 419.0 388.7 353.7 315.7 274.5 232.1 188.3 144.2 100.7 59.42 24.79 0
C90 504.9 502.5 497.3 489.3 476.0 458.5 434.4 405.8 371.5 333.6 291.9 248.3 203.3 157.7 112.5 68.84 19.29 0
C135 504.3 500.5 493.4 482.4 466.9 446.4 420.9 390.3 355.4 317.2 276.4 233.9 190.4 146.4 102.7 61.33 26.16 0
C180 503.4 498.0 488.2 474.0 455.0 431.2 402.7 370.1 334.2 295.6 255.4 213.8 171.5 128.9 87.06 47.91 14.20 0.3774
C225 503.0 497.7 488.9 475.6 457.5 434.3 406.1 373.1 336.3 296.8 255.0 212.2 168.9 126.0 83.80 45.09 16.84 0
C270 502.8 498.6 490.5 478.9 461.5 439.7 411.4 379.0 341.5 301.4 259.1 216.9 173.5 128.6 84.23 43.00 10.57 0
γ
C315 502.5 496.8 487.6 473.8 455.3 431.8 403.5 370.7 333.7 294.2 252.2 209.3 165.9 122.9 80.54 41.93 14.71 0
0- 5 5- 10 10- 15 15- 20 20- 25 25- 30 30- 35 35- 40 40- 45 45- 50 50- 55 55- 60 60- 65 65- 70 70- 75 75- 80 80- 85 85- 90 90- 95 95-100 100-105 105-110 110-115 115-120 120-125 125-130 130-135 135-140 140-145 145-150 150-155 155-160 160-165 165-170 170-175 175-180
Φ zone
12.06 35.85 58.69 79.84 98.55 114.0 125.4 132.3 134.3 131.4 124.0 112.4 97.41 79.42 59.25 38.26 18.93 2.386
LUMINOUS INTENSITY:cd
Φ total
12.06 47.91 106.6 186.4 285.0 398.9 524.4 656.6 790.9 922.3 1046 1159 1256 1336 1395 1433 1452 1454
%lum,lamp 0.83,0.83 3.29,3.29 7.33,7.33 12.8,12.8 19.6,19.6 27.4,27.4 36.1,36.1 45.1,45.1 54.4,54.4 63.4,63.4 71.9,71.9 79.7,79.7 86.4,86.4 91.8,91.8 95.9,95.9 98.5,98.5 99.8,99.8 100,100
UNIT:lm
LUMINANCE LIMITATION CURVES GLARE
CLASS
1.15
A
1.50
B
1.85
C
2.20
D
2.55
E
ILLUMINANCE (lx) 2000
a
G(DEG) 85
a b
c
d
1000
500
2000
1000
500
2000
1000
500
2000
1000
500
<=300
d
2000 e
1000 f
500 g
b
e
f
<=300
c
g
<=300 <=300
<=300 h
h
75
C0/180
C90/270
8 6
85
1028
1495
4
80
1778
2679
3
75
2208
2936
70
2492
3115
65
2694
3250
60
2848
3356
55
2972
3439
50
3078
3506
45
3166
3550
a/h 65
2
55
45
LUMINANCE cd/(m2) G(DEG)
8 1000 C0/180
2
3 4 C90/270
5
6
8
10000
2 3 4 LUMINANCE (cd/(m2))
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:25.6DEG Operators:王 林 飞 Test Date:2010-11-12
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
1
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:60% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 3 Of 12
CU AND LUMINAIRE BUDGETARY ESTIMATE DIAGRAM
ρ cc
80%
ρw
50%
30%
ρ fc
70% 10%
50%
20%
RCR
30%
50% 10%
50%
20%
RCR:Room Cavity Ratio
30%
30% 10%
50%
20%
30%
10% 10%
50%
20%
30%
0 10%
20%
0 0
Coefficients of Utilization(CU)
0.0
1.19 1.19 1.19 1.16 1.16 1.16 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02
.00
1.0
1.04
.00
.96
1.02
.98
.95
.98
.95
.92
.94
.91
.89
.90
.88
.86
.84
2.0
.91
.84
.78
.89
.83
.77
.85
.80
.76
.82
.78
.74
.79
.75
.72
.70
3.0
.80
.72
.65
.78
.71
.65
.75
.69
.63
.72
.67
.62
.70
.65
.61
.59
4.0
.71
.62
.55
.69
.61
.55
.67
.60
.54
.64
.58
.53
.62
.57
.53
.50
5.0
.63
.54
.47
.62
.53
.47
.60
.52
.47
.58
.51
.46
.56
.50
.46
.43
6.0
.57
.48
.41
.56
.47
.41
.54
.46
.41
.52
.46
.40
.51
.45
.40
.38
7.0
.51
.43
.36
.51
.42
.36
.49
.42
.36
.48
.41
.36
.46
.40
.36
.34
8.0
.47
.38
.33
.46
.38
.32
.45
.37
.32
.44
.37
.32
.42
.36
.32
.30
9.0
.43
.35
.29
.42
.35
.29
.41
.34
.29
.40
.34
.29
.39
.33
.29
.27
10.0
.40
.32
.26
.39
.32
.26
.38
.31
.26
.37
.31
.26
.36
.30
.26
.24
LAMPS 50
LUMINAIRE BUDGETARY DIAGRAM
40 30 H=8 20 7
6 10 9 8 7 6
CONDITIONS FLUX 1000lm FACTOR 0.70
5 H=5
Hdown Hwork
5
0.00m 0.80m
Ework(AVE)
4 4
ρ (%)
cc 70
3 3
50 2 2 10
20
30 40 50
70
100
200 300 AREA(m2)
500 700
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:25.6DEG Operators:王 林 飞 Test Date:2010-11-12
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
1k
2k
100lx w fc 50 30 30
3k 4k 5k
20 7k
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:60% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 4 Of 12
WEC AND CCEC
ρ cc ρw
80% 50%
ρ fc
RCR
30%
70% 10%
50%
20%
30%
50% 10%
50%
20%
30%
30% 10%
50%
20%
RCR:Room Cavity Ratio
30%
10% 10%
50%
20%
30%
0 10%
20%
0 0
Wall Exitance Coeffcients(WEC)
0.0 1.0
.304 .173 .055 .297 .169 .054 .283 .163 .052 .271 .156 .050 .260 .151 .049
2.0
.288 .158 .048 .282 .155 .048 .270 .150 .047 .259 .146 .046 .249 .141 .044
3.0
.268 .142 .043 .262 .140 .042 .252 .136 .041 .242 .133 .041 .233 .129 .040
4.0
.247 .129 .038 .243 .127 .038 .233 .124 .037 .225 .121 .036 .217 .118 .036
5.0
.229 .117 .034 .225 .115 .034 .217 .113 .033 .209 .110 .033 .202 .108 .032
6.0
.213 .107 .031 .209 .106 .030 .202 .103 .030 .195 .101 .030 .189 .099 .029
7.0
.198 .098 .028 .195 .097 .028 .188 .095 .027 .182 .093 .027 .177 .092 .027
8.0
.185 .090 .025 .182 .090 .025 .176 .088 .025 .171 .087 .025 .166 .085 .025
9.0
.174 .084 .023 .171 .083 .023 .166 .082 .023 .161 .081 .023 .156 .079 .023
10.0
.163 .078 .022 .161 .078 .022 .156 .077 .022 .152 .075 .021 .148 .074 .021
ρ cc ρw
80% 50%
ρ fc
RCR
30%
70% 10%
50%
20% RCR:Room Cavity Ratio
30% 20%
50% 10%
50%
30%
30% 10%
20%
50%
30% 20%
10% 10%
50%
30%
0 10%
20%
0 0
Ceiling Cavity Exitance Coefficients(CCEC)
0.0
.190 .190 .190 .163 .163 .163 .111 .111 .111 .064 .064 .064 .020 .020 .020
1.0
.180 .156 .135 .154 .134 .116 .105 .092 .080 .061 .053 .047 .019 .017 .015
2.0
.172 .132 .098 .147 .114 .085 .101 .079 .059 .058 .046 .035 .019 .015 .011
3.0
.164 .114 .075 .141 .099 .065 .097 .068 .045 .056 .040 .027 .018 .013 .009
4.0
.156 .101 .059 .134 .087 .051 .092 .061 .036 .053 .036 .021 .017 .012 .007
5.0
.149 .091 .047 .128 .078 .041 .088 .055 .029 .051 .032 .017 .016 .010 .006
6.0
.142 .082 .039 .122 .071 .034 .084 .050 .024 .049 .029 .014 .016 .010 .005
7.0
.135 .075 .033 .116 .065 .029 .080 .046 .021 .047 .027 .012 .015 .009 .004
8.0
.129 .069 .029 .111 .060 .025 .077 .042 .018 .045 .025 .011 .014 .008 .004
9.0
.123 .065 .025 .106 .056 .022 .073 .039 .016 .043 .023 .009 .014 .008 .003
10.0
.117 .060 .022 .101 .052 .020 .070 .037 .014 .041 .022 .008 .013 .007 .003
γ Range: 0 - 90DEG γ Interval: 0.5DEG
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:25.6DEG Operators:王 林 飞 Test Date:2010-11-12
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:60% Test Distance:5.400m [K=1.0000] Remarks:
Checker:
Assessor: 张 树
Light Green International Co.Ltd
Page 5 Of 12
Uncorrected UGR Table
ceiling/cavity
0.7
0.7
0.5
0.5
0.3
0.7
0.7
0.5
0.5
0.3
walls
0.5
0.3
0.5
0.3
0.3
0.5
0.3
0.5
0.3
0.3
working plane
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
2H
16.7
18.2
17.0
18.4
18.6
17.4
18.9
17.7
19.1
19.3
3H
18.1
19.5
18.4
19.7
20.0
19.0
20.4
19.3
20.6
20.9
4H
18.6
19.9
18.9
20.2
20.4
19.7
21.0
20.0
21.2
21.5
6H
18.9
20.2
19.3
20.4
20.7
20.1
21.4
20.5
21.7
21.9
8H
19.0
20.2
19.3
20.5
20.8
20.3
21.5
20.6
21.8
22.1
12H
19.0
20.2
19.3
20.4
20.8
20.4
21.5
20.7
21.8
22.1
2H
17.4
18.7
17.7
19.0
19.2
17.9
19.3
18.3
19.5
19.8
3H
19.0
20.1
19.3
20.4
20.7
19.7
20.9
20.1
21.2
21.5
4H
19.6
20.7
20.0
21.0
21.3
20.5
21.6
20.9
21.9
22.2
6H
20.0
21.0
20.4
21.3
21.7
21.1
22.1
21.5
22.4
22.8
Room dimensions x =
2H y =
4H
Viewed crosswise
Viewed endwise
8H
20.1
21.0
20.6
21.4
21.8
21.4
22.2
21.8
22.6
23.0
12H
20.2
21.0
20.6
21.4
21.8
21.5
22.3
21.9
22.7
23.1
8H
4H
19.9
20.8
20.3
21.2
21.6
20.7
21.6
21.1
22.0
22.4
6H
20.5
21.2
20.9
21.6
22.1
21.5
22.2
21.9
22.6
23.1
8H
20.7
21.3
21.1
21.7
22.2
21.8
22.5
22.3
22.9
23.3
12H
20.8
21.3
21.2
21.8
22.2
22.0
22.6
22.5
23.0
23.5
12H
4H
20.0
20.8
20.4
21.1
21.6
20.7
21.5
21.2
21.9
22.3
6H
20.6
21.2
21.0
21.6
22.1
21.5
22.2
22.0
22.6
23.1
8H
20.8
21.3
21.3
21.8
22.3
21.9
22.4
22.4
22.9
23.4
Variations with the observer position at spacings: S = 1.0H
+ 0.2 / - 0.2
+ 0.1 / - 0.2
1.5H
+ 0.2 / - 0.4
+ 0.2 / - 0.3
2.0H
+ 0.2 / - 0.3
+ 0.2 / - 0.3
CIE Pub.117 Corrected 1454 lm Total Lamp Luminous Flux.(8log(F/F0) = 1.3)
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:25.6DEG Operators:王 林 飞 Test Date:2010-11-12
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:60% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 6 Of 12
UTILIZATION FACTORS TABLE
REFLECTANCE Ceiling
0.8
0.8
0.8
0.7
0.7
0.7
0.5
0.5
0.5
0
Walls
0.7
0.5
0.3
0.7
0.5
0.3
0.7
0.5
0.3
0
Working plane
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0
ROOM INDEX
UTILIZATION FACTORS(PERCENT)
k(RI) x RCR = 5
k = 0.60
58
46
39
57
46
39
56
45
39
33
0.80
68
56
49
67
56
49
65
55
48
42
1.00
76
65
58
75
65
58
73
66
57
50
1.25
83
73
66
82
72
66
79
71
65
58
1.50
88
79
72
87
78
71
84
76
70
63
2.00
95
87
81
93
86
80
90
83
78
70
2.50
99
92
86
97
90
85
93
87
83
75
3.00
103
96
90
100
94
89
96
91
87
79
4.00
107
101
96
104
99
95
100
96
92
83
5.00
109
104
100
106
102
99
102
99
96
86
ROOM INDEX According to DIN EN 13032-2 2004
UF(total)
Direct Suspended
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:25.6DEG Operators:王 林 飞 Test Date:2010-11-12
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
SHRNOM = 1.25
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:60% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 7 Of 12
ISOCANDELA DIAGRAM
90
10% 20% 30% 40% 50% 60% 70% 80% 90%
80 70 60
50.52 101.0 151.6 202.1 252.6 303.1 353.7 404.2 454.7
50 40 30
VERTICAL(DEG)
20 10 0
MAX = 505.25 MIN = 240.00 AVG = 417.77 AVG/MAX = 0.83 MIN/MAX = 0.48
-10 -20 -30 -40 -50 -60 -70
Imax:505.2(H0.0,V0.0) (At:C=0.0,Gamma=0.0)
-80 -90 -90 -80
UNIT: cd -70 -60
-50 -40
-30 -20
-10
0
10
20
30
40
50
60
70
80
90
HORIZONTAL(DEG)
γ Range: 0 - 90DEG γ Interval: 0.5DEG
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:25.6DEG Operators:王 林 飞 Test Date:2010-11-12
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:60% Test Distance:5.400m [K=1.0000] Remarks:
Checker:
Assessor: 张 树
Light Green International Co.Ltd
Page 8 Of 12
AAI Figure
Flux out:1058 lm
3.281ft 1m
14.78,46.94fc 159.1,505.2lx
9.418ft 287.07cm
6.562ft 2m
3.695,11.73fc 39.77,126.3lx
18.84ft 574.13cm
9.843ft 3m
1.642,5.215fc 17.68,56.14lx
28.25ft 861.20cm
13.12ft 4m
0.9237,2.934fc 9.943,31.58lx
37.67ft 1148.26cm
16.4ft 5m
0.5912,1.878fc 6.363,20.21lx
47.09ft 1435.33cm
Height
Eavg,Emax
Angle:110.27deg
Diameter
Note:The Curves indicate the illuminated area and the average illumination when the luminaire is at different distance.
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:25.6DEG Operators:王 林 飞 Test Date:2010-11-12
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:60% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 9 Of 12
ISOLUX DIAGRAM
105.0'
52.5'
0.0'
52.5'
105.0'
131.2'
40.00m
105.0'
32.00m
78.7'
24.00m
52.5'
16.00m
26.2'
8.00m
0.0'
0.00m
26.2'
8.00m
52.5'
16.00m
78.7'
24.00m
105.0'
32.00m
3% 0.1514lx 0.01407fc 5% 0.2524lx 0.02345fc 10% 0.5048lx 0.0469fc 30% 1.514lx 0.1407fc 50% 2.524lx 0.2345fc 60% 3.029lx 0.2814fc 70% 3.534lx 0.3283fc 80% 4.038lx 0.3752fc
131.2'
90% 4.543lx 0.4221fc
40.00m 32.00m
16.00m
0.00m
16.00m
32.00m
MOUNTING HEIGHT: 33'(10.0m)
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:25.6DEG Operators:王 林 飞 Test Date:2010-11-12
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:60% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 10 Of 12
Average Luminance Table(CIBSE)
Parameter description for average Luminance
Symbol
Value
Unit
Luminance in Azimuth Plane
Bc
refer Table 2
cd/sq.m.
Intensity at angle Gamma in given azimuth plane
I
from data
cd/klm
Number of lamps
N
1
Output of each lamp(initial lumens as specified)
F
1454.34
Multiplying factor
K
1
Luminous area in horizontal plane used in calculations Angle to the downward vertical from light centre
lm
A
0.148
sq.m.
Gamma
from data
deg
Table 1. Calculation parameters for determination of CIBSE LG3:1996 Average Luminance
G
C plane(deg)
deg
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
55
2972 3008 3061 3124 3196 3270 3339 3389 3424 3439 3433 3404 3354 3289 3220 3153 3094 3043 3008
60
2848 2889 2948 3016 3094 3173 3246 3303 3340 3356 3349 3318 3265 3198 3123 3049 2983 2928 2889
65
2694 2745 2805 2883 2967 3052 3131 3194 3233 3250 3245 3211 3153 3082 3005 2923 2848 2789 2742
70
2492 2546 2621 2709 2805 2895 2979 3050 3096 3115 3110 3071 3010 2934 2848 2761 2672 2605 2547
75
2208 2275 2364 2468 2576 2680 2777 2856 2915 2936 2932 2884 2817 2729 2633 2531 2429 2340 2273
80
1778 1866 1979 2109 2245 2378 2492 2582 2654 2679 2674 2624 2551 2448 2323 2194 2066 1945 1864
85
1028 1202 1413 1584 1827 2007 1997 1733 1555 1495 1575 1777 2073 2106 1935 1706 1533 1302 1101 Table 2. Average Luminance(cd/sq.m.) for defined C plane,Gamma angle
CIBSE
Gamma
Category
(deg)
Average Luminance
Patch Luminance
maximum
specified
maximum
specified
calculated
maximum
measured
maximum
Category 1
55 to 90
3439
200
---
500
Category 2
65 to 90
3250
200
---
500
Category 3
75 to 90
2936
200
---
500
Table 3. Tabulation of Average and Patch Luminance(cd/sq.m.) for defined CIBSE categories No match
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:25.6DEG Operators:王 林 飞 Test Date:2010-11-12
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:60% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 11 Of 12
Average Luminance Table(CIBSE)
Parameter description for average Luminance
Symbol
Value
Unit
Luminance in Azimuth Plane
Bc
refer Table 2
cd/sq.m.
Intensity at angle Gamma in given azimuth plane
I
from data
cd/klm
Number of lamps
N
1
Output of each lamp(initial lumens as specified)
F
1454.34
Multiplying factor
K
1
Luminous area in horizontal plane used in calculations Angle to the downward vertical from light centre
lm
A
0.148
sq.m.
Gamma
from data
deg
Table 1. Calculation parameters for determination of CIBSE LG3:2001 Average Luminance
G deg
C plane(deg) 0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
55
2972 3008 3061 3124 3196 3270 3339 3389 3424 3439 3433 3404 3354 3289 3220 3153 3094 3043 3008
60
2848 2889 2948 3016 3094 3173 3246 3303 3340 3356 3349 3318 3265 3198 3123 3049 2983 2928 2889
65
2694 2745 2805 2883 2967 3052 3131 3194 3233 3250 3245 3211 3153 3082 3005 2923 2848 2789 2742
70
2492 2546 2621 2709 2805 2895 2979 3050 3096 3115 3110 3071 3010 2934 2848 2761 2672 2605 2547
75
2208 2275 2364 2468 2576 2680 2777 2856 2915 2936 2932 2884 2817 2729 2633 2531 2429 2340 2273
80
1778 1866 1979 2109 2245 2378 2492 2582 2654 2679 2674 2624 2551 2448 2323 2194 2066 1945 1864
85
1028 1202 1413 1584 1827 2007 1997 1733 1555 1495 1575 1777 2073 2106 1935 1706 1533 1302 1101 Table 2. Average Luminance(cd/sq.m.) for defined C plane,Gamma angle
Average Luminance(cd/sq.m) range
Maximum
(deg)
measured
Maximum limit for screen type & software category used Type I,II screen Type I,II screen Type III screen
Type III screen
Some neg.s'ware
Only pos.s'ware
Some neg.s'ware
Only pos.s'ware
55 to 90
3439
1000
1500
200
500
65 to 90
3250
1000
1500
200
500
Table 3. Tabulation of average luminance(cd/sq.m.) and luminance limits No match
γ Range: 0 - 90DEG γ Interval: 0.5DEG
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:25.6DEG Operators:王 林 飞 Test Date:2010-11-12
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:60% Test Distance:5.400m [K=1.0000] Remarks:
Checker:
Assessor: 张 树
Light Green International Co.Ltd
Page 12 Of 12
Planar Illuminance Curve
Planar Illuminance Curve E(lx) 5.5
MH = 10 m C0/180 C90/270
4.95
4.4
3.85
3.3
2.75
2.2
1.65
1.1
0.55
0 -25
-20
-15
-10
-5
0
5
10
15
20
25
Distance(m)
γ Range: 0 - 90DEG γ Interval: 0.5DEG
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:25.6DEG Operators:王 林 飞 Test Date:2010-11-12
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:60% Test Distance:5.400m [K=1.0000] Remarks:
Checker:
Assessor: 张 树
Light Green International Co.Ltd
Page 1 Of 12
LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:228.8V I:0.3230A P:38.30W PF:0.5180
Lamp Flux:2278.36x1 lm
NAME: LED Panel Light
TYPE:natrual white
DIM.:
SPEC.:
MFR.: Light Green International Co.,Ltd
SUR.:1.164*0.265
DATA OF LAMP
PHOTOMETRIC DATA
LGI-C0312WBA-Q
MODEL
WEIGHT:5KG
Eff: 59.49 lm/W
Imax(cd)
813.9
S/MH(C0/180)
1.25
NOMINAL POWER(W)
38
LOR(%)
100.0
S/MH(C90/270)
1.30
RATED VOLTAGE(V)
230
TOTAL FLUX(lm)
2278.4
η UP,DN(C0-180)
0.0,52.2
NOMINAL FLUX(lm)
2278.36
CIE CLASS
DIRECT
η UP,DN(C180-360)
0.0,47.8
LAMPS INSIDE
1
η up(%)
0.0
CIBSE SHR NOM
1.25
TEST VOLTAGE(V)
229.0
η down(%)
100.0
CIBSE SHR MAX
1.35
LUMINOUS INTENSITY DISTRIBUTION DIAGRAM
C0 PLANE ISOLUX DIAGRAM (UNIT:lx) MH(m) 8 10
-/+180 -150
150
13 -120
120
15 18
-90
0
90
170
23
340 -60
510
25 60
UNIT:cd C0/180,111.0° C30/210,110.8° -30 30 850 C60/240,111.6° 0 C90/270,111.9° AVERAGE BEAM ANGLE(50%):111.3 DEG
680
20
28 0.0
AAAAAAAAAAAAAAAAAAAAAAAAAAA
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:20.8DEG Operators:王 林 飞 Test Date:2011-01-11
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
10.5 20.0 16.0 13.0 9.80 6.50
3.30 2.60 1.60 1.30 0.9800
21.0 S(m)
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:36% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 2 Of 12
ZONAL FLUX DIAGRAM AND LUMINANCE LIMITATION CURVES
ZONAL FLUX DIAGRAM: γ
C0 810.2 799.4 781.7 756.7 725.0 686.3 641.4 591.3 536.0 476.9 414.4 349.4 281.2 213.2 145.4 79.63 19.86 2.652
5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 DEG
C45 809.9 802.4 789.5 766.1 739.3 703.2 659.6 612.7 556.8 500.5 436.4 372.5 303.5 234.5 165.0 99.58 25.59 0
C90 811.0 808.0 793.1 778.1 748.0 717.8 673.9 629.9 573.6 517.2 451.9 386.7 316.6 246.5 176.7 106.8 0 0
C135 810.2 802.9 790.2 767.1 740.5 703.0 660.4 614.3 558.4 502.3 437.6 373.1 304.0 234.9 165.3 99.50 25.47 0
C180 810.6 799.9 782.4 757.5 726.2 685.2 640.4 589.8 534.4 474.6 411.8 346.3 278.9 210.0 141.6 75.81 16.39 0.7370
C225 806.2 794.8 777.9 750.2 717.0 676.3 628.7 578.1 518.4 458.8 391.9 325.3 255.2 186.0 117.5 60.28 11.67 0
C270 805.3 796.7 775.2 753.7 716.1 678.4 627.7 576.9 515.4 454.0 385.9 317.9 247.0 176.2 113.3 50.36 0 0
γ
C315 805.9 794.5 777.5 749.4 718.0 677.0 628.6 577.3 517.7 458.0 391.1 324.6 254.4 185.1 116.9 60.00 11.61 0
0- 5 5- 10 10- 15 15- 20 20- 25 25- 30 30- 35 35- 40 40- 45 45- 50 50- 55 55- 60 60- 65 65- 70 70- 75 75- 80 80- 85 85- 90 90- 95 95-100 100-105 105-110 110-115 115-120 120-125 125-130 130-135 135-140 140-145 145-150 150-155 155-160 160-165 165-170 170-175 175-180
Φ zone
19.38 57.51 93.84 127.1 156.1 179.4 196.7 206.9 210.0 205.6 194.4 176.4 152.8 124.1 92.12 58.95 25.13 2.008
LUMINOUS INTENSITY:cd
Φ total
19.38 76.89 170.7 297.8 453.9 633.3 830.0 1037 1247 1452 1647 1823 1976 2100 2192 2251 2276 2278
%lum,lamp 0.85,0.85 3.37,3.37 7.49,7.49 13.1,13.1 19.9,19.9 27.8,27.8 36.4,36.4 45.5,45.5 54.7,54.7 63.8,63.8 72.3,72.3 80,80 86.7,86.7 92.2,92.2 96.2,96.2 98.8,98.8 99.9,99.9 100,100
UNIT:lm
LUMINANCE LIMITATION CURVES GLARE
CLASS
1.15
A
1.50
B
1.85
C
2.20
D
2.55
E
ILLUMINANCE (lx) 2000
a
G(DEG) 85
a
1000
500
2000
1000
500
2000
1000
500
2000
1000
500
<=300
d
2000 e
1000 f
500 g
b
b
c
<=300
c
d
<=300
e
f
<=300
g
<=300 h
h
75
C90/270
85
739
0
4
80
1486
1994
3
75
1821
2213
70
2021
2336
65
2157
2428
60
2265
2507
55
2342
2554
50
2405
2608
45
2457
2629
2
55
45
C0/180
8 6
a/h 65
LUMINANCE cd/(m2) G(DEG)
8 1000 C0/180
2
3 4 C90/270
5
6
8
10000
2 3 4 LUMINANCE (cd/(m2))
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:20.8DEG Operators:王 林 飞 Test Date:2011-01-11
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
1
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:36% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 3 Of 12
CU AND LUMINAIRE BUDGETARY ESTIMATE DIAGRAM
ρ cc
80%
ρw
50%
30%
ρ fc
70% 10%
50%
20%
RCR
30%
50% 10%
50%
20%
RCR:Room Cavity Ratio
30%
30% 10%
50%
20%
30%
10% 10%
50%
20%
30%
0 10%
20%
0 0
Coefficients of Utilization(CU)
0.0
1.19 1.19 1.19 1.16 1.16 1.16 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.00
1.0
1.04 1.00
.96
1.02
.98
.95
.98
.95
.92
.94
.91
.89
.90
.88
.86
.84
2.0
.91
.84
.79
.89
.83
.78
.86
.80
.76
.82
.78
.74
.79
.76
.73
.70
3.0
.80
.72
.65
.78
.71
.65
.75
.69
.64
.73
.67
.63
.70
.65
.61
.59
4.0
.71
.62
.55
.70
.61
.55
.67
.60
.54
.65
.59
.54
.63
.57
.53
.51
5.0
.63
.54
.48
.62
.54
.47
.60
.53
.47
.58
.52
.46
.56
.50
.46
.44
6.0
.57
.48
.42
.56
.48
.41
.54
.47
.41
.53
.46
.41
.51
.45
.40
.38
7.0
.52
.43
.37
.51
.43
.37
.49
.42
.36
.48
.41
.36
.46
.40
.36
.34
8.0
.47
.39
.33
.46
.38
.33
.45
.38
.32
.44
.37
.32
.43
.37
.32
.30
9.0
.43
.35
.29
.43
.35
.29
.41
.34
.29
.40
.34
.29
.39
.33
.29
.27
10.0
.40
.32
.27
.39
.32
.27
.38
.31
.27
.37
.31
.26
.37
.31
.26
.25
LAMPS 50
LUMINAIRE BUDGETARY DIAGRAM
40 30 H=8 20 7 6 10 9 8 7 6
CONDITIONS FLUX 1000lm FACTOR 0.70
5 H=5
Hdown Hwork
5
0.00m 0.80m
Ework(AVE)
4 4
ρ (%)
cc 70
3 3
50 2 2 10
20
30 40 50
70
100
200 300 AREA(m2)
500 700
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:20.8DEG Operators:王 林 飞 Test Date:2011-01-11
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
1k
2k
100lx w fc 50 30 30
3k 4k 5k
20 7k
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:36% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 4 Of 12
WEC AND CCEC
ρ cc ρw
80% 50%
ρ fc
RCR
30%
70% 10%
50%
20%
30%
50% 10%
50%
20%
30%
30% 10%
50%
20%
RCR:Room Cavity Ratio
30%
10% 10%
50%
20%
30%
0 10%
20%
0 0
Wall Exitance Coeffcients(WEC)
0.0 1.0
.300 .171 .054 .293 .167 .053 .280 .161 .051 .268 .154 .050 .257 .149 .048
2.0
.286 .157 .048 .280 .154 .047 .268 .149 .046 .257 .144 .045 .247 .140 .044
3.0
.266 .142 .042 .261 .140 .042 .250 .136 .041 .241 .132 .040 .232 .128 .040
4.0
.246 .128 .038 .242 .126 .037 .232 .123 .037 .224 .120 .036 .216 .117 .036
5.0
.228 .116 .034 .224 .115 .033 .216 .112 .033 .208 .110 .033 .201 .108 .032
6.0
.212 .106 .030 .208 .105 .030 .201 .103 .030 .194 .101 .030 .188 .099 .029
7.0
.198 .098 .028 .194 .097 .028 .188 .095 .027 .182 .093 .027 .176 .091 .027
8.0
.185 .090 .025 .182 .089 .025 .176 .088 .025 .170 .086 .025 .165 .085 .025
9.0
.173 .084 .023 .170 .083 .023 .165 .082 .023 .160 .080 .023 .156 .079 .023
10.0
.163 .078 .022 .160 .078 .022 .156 .076 .021 .151 .075 .021 .147 .074 .021
ρ cc ρw
80% 50%
ρ fc
RCR
30%
70% 10%
50%
20% RCR:Room Cavity Ratio
30% 20%
50% 10%
50%
30%
30% 10%
20%
50%
30% 20%
10% 10%
50%
30%
0 10%
20%
0 0
Ceiling Cavity Exitance Coefficients(CCEC)
0.0
.190 .190 .190 .163 .163 .163 .111 .111 .111 .064 .064 .064 .020 .020 .020
1.0
.180 .156 .135 .154 .134 .116 .105 .092 .080 .061 .053 .047 .019 .017 .015
2.0
.171 .132 .099 .147 .114 .085 .101 .079 .060 .058 .046 .035 .019 .015 .011
3.0
.164 .114 .075 .140 .099 .065 .096 .068 .046 .056 .040 .027 .018 .013 .009
4.0
.156 .101 .059 .134 .087 .051 .092 .061 .036 .053 .036 .021 .017 .012 .007
5.0
.149 .091 .047 .128 .078 .041 .088 .055 .029 .051 .032 .017 .016 .010 .006
6.0
.142 .082 .039 .122 .071 .034 .084 .050 .024 .049 .029 .014 .016 .010 .005
7.0
.135 .075 .033 .116 .065 .029 .080 .046 .021 .047 .027 .012 .015 .009 .004
8.0
.129 .069 .029 .111 .060 .025 .077 .042 .018 .045 .025 .011 .014 .008 .004
9.0
.122 .064 .025 .106 .056 .022 .073 .039 .016 .043 .023 .009 .014 .008 .003
10.0
.117 .060 .022 .101 .052 .020 .070 .037 .014 .041 .022 .008 .013 .007 .003
γ Range: 0 - 90DEG γ Interval: 0.5DEG
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:20.8DEG Operators:王 林 飞 Test Date:2011-01-11
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:36% Test Distance:5.400m [K=1.0000] Remarks:
Checker:
Assessor: 张 树
Light Green International Co.Ltd
Page 5 Of 12
Uncorrected UGR Table
ceiling/cavity
0.7
0.7
0.5
0.5
0.3
0.7
0.7
0.5
0.5
0.3
walls
0.5
0.3
0.5
0.3
0.3
0.5
0.3
0.5
0.3
0.3
working plane
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
2H
16.0
17.5
16.2
17.7
17.9
16.4
17.9
16.7
18.1
18.3
3H
17.4
18.8
17.7
19.1
19.3
18.0
19.4
18.3
19.6
19.9
4H
18.0
19.3
18.3
19.6
19.8
18.7
20.0
19.0
20.2
20.5
6H
18.3
19.6
18.7
19.8
20.1
19.1
20.4
19.5
20.7
20.9
8H
18.4
19.6
18.7
19.9
20.2
19.2
20.4
19.6
20.7
21.0
12H
18.4
19.5
18.7
19.8
20.1
19.2
20.4
19.6
20.7
21.0
2H
16.7
18.0
17.0
18.2
18.5
17.0
18.3
17.3
18.6
18.8
3H
18.3
19.5
18.7
19.8
20.1
18.8
19.9
19.1
20.2
20.5
4H
19.0
20.0
19.4
20.4
20.7
19.6
20.6
19.9
20.9
21.3
6H
19.4
20.4
19.8
20.7
21.1
20.2
21.1
20.6
21.5
21.8
Room dimensions x =
2H y =
4H
Viewed crosswise
Viewed endwise
8H
19.5
20.4
20.0
20.8
21.2
20.3
21.2
20.7
21.6
21.9
12H
19.6
20.4
20.0
20.8
21.2
20.3
21.1
20.7
21.5
21.9
8H
4H
19.3
20.2
19.7
20.5
20.9
19.8
20.7
20.2
21.1
21.4
6H
19.9
20.6
20.4
21.0
21.5
20.6
21.3
21.0
21.7
22.1
8H
20.1
20.7
20.6
21.2
21.6
20.8
21.4
21.2
21.8
22.3
12H
20.2
20.7
20.7
21.2
21.7
20.8
21.3
21.3
21.8
22.3
12H
4H
19.3
20.1
19.7
20.5
20.9
19.8
20.6
20.3
21.0
21.4
6H
20.0
20.6
20.4
21.0
21.5
20.6
21.3
21.1
21.7
22.1
8H
20.2
20.8
20.7
21.2
21.7
20.9
21.4
21.3
21.8
22.3
Variations with the observer position at spacings: S = 1.0H
+ 0.2 / - 0.2
+ 0.1 / - 0.2
1.5H
+ 0.2 / - 0.3
+ 0.2 / - 0.3
2.0H
+ 0.2 / - 0.3
+ 0.2 / - 0.3
CIE Pub.117 Corrected 2278 lm Total Lamp Luminous Flux.(8log(F/F0) = 2.9)
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:20.8DEG Operators:王 林 飞 Test Date:2011-01-11
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:36% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 6 Of 12
UTILIZATION FACTORS TABLE
REFLECTANCE Ceiling
0.8
0.8
0.8
0.7
0.7
0.7
0.5
0.5
0.5
0
Walls
0.7
0.5
0.3
0.7
0.5
0.3
0.7
0.5
0.3
0
Working plane
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0
ROOM INDEX
UTILIZATION FACTORS(PERCENT)
k(RI) x RCR = 5
k = 0.60
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
0.80
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
1.00
83
74
68
82
73
67
80
74
67
61
1.25
89
80
74
88
80
74
86
78
73
67
1.50
94
86
80
93
85
80
90
83
79
72
2.00
100
92
87
98
91
86
95
89
85
78
2.50
103
96
91
101
95
90
97
92
88
81
3.00
105
100
95
103
98
94
99
95
92
84
4.00
108
103
99
106
102
98
102
98
95
87
5.00
110
106
102
108
104
101
103
100
98
89
ROOM INDEX According to DIN EN 13032-2 2004
UF(total)
Direct Suspended
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:20.8DEG Operators:王 林 飞 Test Date:2011-01-11
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
SHRNOM = 2.00
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:36% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 7 Of 12
ISOCANDELA DIAGRAM
90
10% 20% 30% 40% 50% 60% 70% 80% 90%
80 70 60
81.39 162.8 244.2 325.6 407.0 488.3 569.7 651.1 732.5
50 40 30
VERTICAL(DEG)
20 10 0
MAX = 813.90 MIN = 385.39 AVG = 660.79 AVG/MAX = 0.81 MIN/MAX = 0.47
-10 -20 -30 -40 -50 -60 -70
Imax:813.9(H0.0,V0.0) (At:C=0.0,Gamma=0.0)
-80 -90 -90 -80
UNIT: cd -70 -60
-50 -40
-30 -20
-10
0
10
20
30
40
50
60
70
80
90
HORIZONTAL(DEG)
γ Range: 0 - 90DEG γ Interval: 0.5DEG
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:20.8DEG Operators:王 林 飞 Test Date:2011-01-11
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:36% Test Distance:5.400m [K=1.0000] Remarks:
Checker:
Assessor: 张 树
Light Green International Co.Ltd
Page 8 Of 12
AAI Figure
Flux out:1665 lm
3.281ft 1m
23.26,75.61fc 250.4,813.9lx
9.538ft 290.73cm
6.562ft 2m
5.816,18.90fc 62.60,203.5lx
19.08ft 581.46cm
9.843ft 3m
2.585,8.402fc 27.82,90.43lx
28.61ft 872.18cm
13.12ft 4m
1.454,4.726fc 15.65,50.87lx
38.15ft 1162.91cm
16.4ft 5m
0.9305,3.025fc 10.02,32.56lx
47.69ft 1453.64cm
Height
Eavg,Emax
Angle:110.95deg
Diameter
Note:The Curves indicate the illuminated area and the average illumination when the luminaire is at different distance.
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:20.8DEG Operators:王 林 飞 Test Date:2011-01-11
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:36% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 9 Of 12
ISOLUX DIAGRAM
52.5'
26.2'
0.0'
26.2'
52.5'
65.6'
20.00m
52.5'
16.00m
39.4'
12.00m
26.2'
8.00m
13.1'
4.00m
0.0'
0.00m
13.1'
4.00m
26.2'
8.00m
39.4'
12.00m
52.5'
16.00m
3% 0.9767lx 0.09074fc 5% 1.628lx 0.1512fc 10% 3.256lx 0.3025fc 30% 9.767lx 0.9074fc
65.6'
50% 16.28lx 1.512fc
20.00m 16.00m
8.00m
0.00m
8.00m
16.00m
MOUNTING HEIGHT: 16'(5.0m)
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:20.8DEG Operators:王 林 飞 Test Date:2011-01-11
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:36% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 10 Of 12
Average Luminance Table(CIBSE)
Parameter description for average Luminance
Symbol
Value
Unit
Luminance in Azimuth Plane
Bc
refer Table 2
cd/sq.m.
Intensity at angle Gamma in given azimuth plane
I
from data
cd/klm
Number of lamps
N
1
Output of each lamp(initial lumens as specified)
F
2278.36
Multiplying factor
K
1
Luminous area in horizontal plane used in calculations Angle to the downward vertical from light centre
lm
A
0.3085
sq.m.
Gamma
from data
deg
Table 1. Calculation parameters for determination of CIBSE LG3:1996 Average Luminance
G
C plane(deg)
deg
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
55
2342 2352 2382 2412 2451 2486 2519 2535 2549 2554 2550 2539 2524 2492 2459 2419 2384 2354 2327
60
2265 2280 2317 2354 2391 2427 2455 2481 2499 2507 2502 2485 2460 2431 2396 2361 2320 2278 2245
65
2157 2185 2218 2265 2308 2351 2384 2406 2422 2428 2424 2411 2390 2356 2311 2267 2221 2185 2139
70
2021 2047 2098 2149 2203 2242 2280 2308 2329 2336 2332 2315 2285 2247 2207 2149 2096 2040 1991
75
1821 1857 1926 1985 2039 2095 2147 2181 2205 2213 2207 2185 2150 2100 2042 1984 1914 1841 1773
80
1486 1504 1646 1733 1826 1886 1932 1962 1987 1994 1987 1961 1929 1887 1824 1728 1637 1472 1415
85
739
951
1245 1340 1101 795
488
230
60
0
60
229
487
793
1094 1326 1232 901
610
Table 2. Average Luminance(cd/sq.m.) for defined C plane,Gamma angle
CIBSE
Gamma
Category
(deg)
Average Luminance
Patch Luminance
maximum
specified
maximum
specified
calculated
maximum
measured
maximum
Category 1
55 to 90
2554
500
1000
1500
Category 2
65 to 90
2428
500
2000
1500
Category 3
75 to 90
2213
500
3000
1500
Table 3. Tabulation of Average and Patch Luminance(cd/sq.m.) for defined CIBSE categories No match
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:20.8DEG Operators:王 林 飞 Test Date:2011-01-11
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:36% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 11 Of 12
Average Luminance Table(CIBSE)
Parameter description for average Luminance
Symbol
Value
Unit
Luminance in Azimuth Plane
Bc
refer Table 2
cd/sq.m.
Intensity at angle Gamma in given azimuth plane
I
from data
cd/klm
Number of lamps
N
1
Output of each lamp(initial lumens as specified)
F
2278.36
Multiplying factor
K
1
Luminous area in horizontal plane used in calculations Angle to the downward vertical from light centre
lm
A
0.3085
sq.m.
Gamma
from data
deg
Table 1. Calculation parameters for determination of CIBSE LG3:2001 Average Luminance
G deg
C plane(deg) 0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
55
2342 2352 2382 2412 2451 2486 2519 2535 2549 2554 2550 2539 2524 2492 2459 2419 2384 2354 2327
60
2265 2280 2317 2354 2391 2427 2455 2481 2499 2507 2502 2485 2460 2431 2396 2361 2320 2278 2245
65
2157 2185 2218 2265 2308 2351 2384 2406 2422 2428 2424 2411 2390 2356 2311 2267 2221 2185 2139
70
2021 2047 2098 2149 2203 2242 2280 2308 2329 2336 2332 2315 2285 2247 2207 2149 2096 2040 1991
75
1821 1857 1926 1985 2039 2095 2147 2181 2205 2213 2207 2185 2150 2100 2042 1984 1914 1841 1773
80
1486 1504 1646 1733 1826 1886 1932 1962 1987 1994 1987 1961 1929 1887 1824 1728 1637 1472 1415
85
739
951
1245 1340 1101 795
488
230
60
0
60
229
487
793
1094 1326 1232 901
610
Table 2. Average Luminance(cd/sq.m.) for defined C plane,Gamma angle
Average Luminance(cd/sq.m) range
Maximum
(deg)
measured
Maximum limit for screen type & software category used Type I,II screen Type I,II screen Type III screen
Type III screen
Some neg.s'ware
Only pos.s'ware
Some neg.s'ware
Only pos.s'ware
55 to 90
2554
1000
1500
200
500
65 to 90
2428
1000
1500
200
500
Table 3. Tabulation of average luminance(cd/sq.m.) and luminance limits No match
γ Range: 0 - 90DEG γ Interval: 0.5DEG
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:20.8DEG Operators:王 林 飞 Test Date:2011-01-11
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:36% Test Distance:5.400m [K=1.0000] Remarks:
Checker:
Assessor: 张 树
Light Green International Co.Ltd
Page 12 Of 12
Planar Illuminance Curve
Planar Illuminance Curve E(lx) 35
MH = 5 m C0/180 C90/270
31.5
28
24.5
21
17.5
14
10.5
7
3.5
0 -25
-20
-15
-10
-5
0
5
10
15
20
25
Distance(m)
γ Range: 0 - 90DEG γ Interval: 0.5DEG
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:20.8DEG Operators:王 林 飞 Test Date:2011-01-11
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:36% Test Distance:5.400m [K=1.0000] Remarks:
Checker:
Assessor: 张 树
Light Green International Co.Ltd
Page 1 Of 12
LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:229.1V I:0.3240A P:38.70W PF:0.5200
Lamp Flux:2197.17x1 lm
NAME: LED Panel Light
TYPE:cool white
DIM.:
SPEC.:
MFR.: Light-green
SUR.:0.563m*0.563m
DATA OF LAMP
PHOTOMETRIC DATA
LGI-C0606WDA-Q
MODEL
WEIGHT:5KG
Eff: 56.77 lm/W
Imax(cd)
756.9
S/MH(C0/180)
1.27
NOMINAL POWER(W)
40
LOR(%)
100.0
S/MH(C90/270)
1.34
RATED VOLTAGE(V)
230
TOTAL FLUX(lm)
2197.2
η UP,DN(C0-180)
0.0,50.6
NOMINAL FLUX(lm)
2197.17
CIE CLASS
DIRECT
η UP,DN(C180-360)
0.0,49.4
LAMPS INSIDE
1
η up(%)
0.0
CIBSE SHR NOM
1.25
TEST VOLTAGE(V)
229.2
η down(%)
100.0
CIBSE SHR MAX
1.35
LUMINOUS INTENSITY DISTRIBUTION DIAGRAM
C0 PLANE ISOLUX DIAGRAM (UNIT:lx) MH(m) 14 18
-/+180 -150
150
22 -120
120
26 30
-90
0
90
160
38
320 -60
480
42 60
UNIT:cd C0/180,111.1° C30/210,112.5° -30 30 800 C60/240,115.3° 0 C90/270,116.6° AVERAGE BEAM ANGLE(50%):113.9 DEG
640
34
46 0.0
AAAAAAAAAAAAAAAAAAAAAAAAAAA
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:24.6DEG Operators:王 林 飞 Test Date:2010-11-10
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
17.0 4.50 3.80 3.00 2.30 1.50
34.0 S(m) 0.7600 0.6100 0.3800 0.3000 0.2300
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:53% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 2 Of 12
ZONAL FLUX DIAGRAM AND LUMINANCE LIMITATION CURVES
ZONAL FLUX DIAGRAM: γ
C0 754.0 745.4 730.9 708.9 680.8 645.7 603.9 556.0 502.6 445.0 384.0 321.1 256.9 192.4 129.1 70.02 21.69 2.057
5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 DEG
C45 754.5 747.9 736.7 719.7 695.5 664.4 626.3 581.0 528.7 471.8 409.7 345.3 278.5 211.1 144.5 82.02 31.13 0
C90 755.4 751.0 742.6 730.6 709.9 683.7 647.4 604.4 552.1 494.6 431.1 364.8 295.7 225.9 156.7 90.80 23.26 0
C135 754.6 747.9 736.6 719.2 696.0 665.3 626.9 581.5 529.1 471.9 410.0 345.5 279.2 212.0 145.7 83.34 32.22 0
C180 754.0 745.5 731.2 710.3 682.4 647.3 605.4 557.2 504.0 446.4 386.0 322.9 258.9 194.4 130.8 71.24 21.81 0.7576
C225 754.4 747.2 734.9 715.6 690.3 657.2 616.6 569.5 516.3 459.0 397.5 333.9 269.6 203.0 135.8 73.78 25.23 0
C270 755.0 749.7 738.9 723.7 698.6 668.3 628.6 583.0 529.6 472.2 411.6 349.6 277.0 206.7 137.4 71.75 16.22 0
γ
C315 754.3 747.0 734.5 715.6 689.0 655.3 614.8 567.8 514.6 457.4 395.6 331.9 266.9 199.3 132.0 70.13 23.04 0
0- 5 5- 10 10- 15 15- 20 20- 25 25- 30 30- 35 35- 40 40- 45 45- 50 50- 55 55- 60 60- 65 65- 70 70- 75 75- 80 80- 85 85- 90 90- 95 95-100 100-105 105-110 110-115 115-120 120-125 125-130 130-135 135-140 140-145 145-150 150-155 155-160 160-165 165-170 170-175 175-180
Φ zone
18.06 53.73 87.99 119.8 148.0 171.3 188.8 199.5 203.1 199.3 188.6 171.5 148.8 121.0 89.92 57.45 27.12 3.172
LUMINOUS INTENSITY:cd
Φ total
18.06 71.80 159.8 279.6 427.6 598.9 787.7 987.2 1190 1390 1578 1750 1898 2020 2109 2167 2194 2197
%lum,lamp 0.82,0.82 3.27,3.27 7.27,7.27 12.7,12.7 19.5,19.5 27.3,27.3 35.8,35.8 44.9,44.9 54.2,54.2 63.2,63.2 71.8,71.8 79.6,79.6 86.4,86.4 91.9,91.9 96,96 98.6,98.6 99.9,99.9 100,100
UNIT:lm
LUMINANCE LIMITATION CURVES GLARE
CLASS
1.15
A
1.50
B
1.85
C
2.20
D
2.55
E
ILLUMINANCE (lx) 2000
a
G(DEG) 85
a
1000
500
2000
1000
500
2000
1000
500
2000
1000
500
<=300
d
2000 e
1000 f
500 g
b
b
c
<=300
c
d
<=300
e
f
<=300
g
<=300 h
h
75
C90/270
85
785
842
4
80
1272
1650
3
75
1573
1910
70
1774
2083
65
1917
2207
60
2026
2301
55
2112
2371
50
2184
2427
45
2242
2463
2
55
45
C0/180
8 6
a/h 65
LUMINANCE cd/(m2) G(DEG)
8 1000 C0/180
2
3 4 C90/270
5
6
8
10000
2 3 4 LUMINANCE (cd/(m2))
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:24.6DEG Operators:王 林 飞 Test Date:2010-11-10
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
1
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:53% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 3 Of 12
CU AND LUMINAIRE BUDGETARY ESTIMATE DIAGRAM
ρ cc
80%
ρw
50%
30%
ρ fc
70% 10%
50%
30%
RCR
30%
50% 10%
50%
30%
RCR:Room Cavity Ratio
30%
30% 10%
50%
30%
30%
10% 10%
50%
30%
30%
0 10%
30%
0 0
Coefficients of Utilization(CU)
0.0
1.32 1.32 1.32 1.27 1.27 1.27 1.18 1.18 1.18 1.10 1.10 1.10 1.03 1.03 1.03 1.00
1.0
1.13 1.08 1.03 1.09 1.04 1.00 1.02
.99
.95
.97
.94
.91
.91
.89
.87
.84
2.0
.97
.89
.82
.94
.87
.81
.89
.83
.78
.84
.79
.75
.80
.76
.73
.70
3.0
.84
.75
.67
.82
.73
.66
.78
.71
.65
.74
.68
.63
.71
.66
.61
.59
4.0
.74
.64
.56
.72
.63
.56
.69
.61
.55
.66
.59
.54
.63
.57
.53
.50
5.0
.65
.55
.48
.64
.55
.48
.61
.53
.47
.59
.52
.46
.57
.51
.46
.43
6.0
.59
.49
.42
.57
.48
.42
.55
.47
.41
.53
.46
.41
.51
.45
.40
.38
7.0
.53
.43
.37
.52
.43
.37
.50
.42
.36
.48
.41
.36
.47
.40
.36
.33
8.0
.48
.39
.33
.47
.39
.33
.46
.38
.32
.44
.37
.32
.43
.37
.32
.30
9.0
.44
.35
.29
.43
.35
.29
.42
.34
.29
.41
.34
.29
.40
.33
.29
.27
10.0
.40
.32
.27
.40
.32
.26
.39
.31
.26
.38
.31
.26
.37
.30
.26
.24
LAMPS 50
LUMINAIRE BUDGETARY DIAGRAM
40 30 H=8 20 7 6 10 9 8 7 6
CONDITIONS FLUX 1000lm FACTOR 0.70
5 H=5
Hdown Hwork
5
0.00m 0.80m
Ework(AVE)
4 4
ρ (%)
cc 70
3 3
50 2 2 10
20
30 40 50
70
100
200 300 AREA(m2)
500 700
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:24.6DEG Operators:王 林 飞 Test Date:2010-11-10
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
1k
2k
100lx w fc 50 30 30
3k 4k 5k
20 7k
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:53% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 4 Of 12
WEC AND CCEC
ρ cc ρw
80% 50%
ρ fc
RCR
30%
70% 10%
50%
30%
30%
50% 10%
50%
30%
30%
30% 10%
50%
30%
RCR:Room Cavity Ratio
30%
10% 10%
50%
30%
30%
0 10%
30%
0 0
Wall Exitance Coeffcients(WEC)
0.0 1.0
.355 .201 .063 .343 .194 .061 .320 .183 .058 .301 .173 .055 .283 .164 .053
2.0
.327 .178 .054 .317 .173 .053 .299 .165 .051 .283 .158 .049 .269 .152 .048
3.0
.298 .157 .047 .290 .154 .046 .275 .148 .045 .262 .143 .043 .250 .138 .042
4.0
.271 .139 .041 .265 .137 .040 .252 .133 .039 .241 .129 .039 .231 .125 .038
5.0
.248 .125 .036 .243 .123 .036 .232 .120 .035 .223 .117 .034 .214 .114 .034
6.0
.228 .113 .032 .224 .112 .032 .215 .109 .032 .206 .106 .031 .198 .104 .031
7.0
.211 .103 .029 .207 .102 .029 .199 .100 .029 .192 .098 .028 .185 .096 .028
8.0
.196 .095 .026 .192 .094 .026 .186 .092 .026 .179 .090 .026 .173 .088 .026
9.0
.183 .088 .024 .180 .087 .024 .174 .085 .024 .168 .084 .024 .163 .082 .024
10.0
.171 .081 .022 .168 .081 .022 .163 .079 .022 .158 .078 .022 .153 .077 .022
ρ cc ρw
80% 50%
ρ fc
RCR
30%
70% 10%
50%
30% RCR:Room Cavity Ratio
30% 30%
50% 10%
50%
30%
30% 10%
30%
50%
30% 30%
10% 10%
50%
30%
0 10%
30%
0 0
Ceiling Cavity Exitance Coefficients(CCEC)
0.0
.316 .316 .316 .266 .266 .266 .176 .176 .176 .099 .099 .099 .031 .031 .031
1.0
.273 .241 .213 .231 .205 .181 .155 .138 .123 .087 .079 .071 .028 .025 .022
2.0
.242 .191 .149 .205 .163 .128 .138 .111 .088 .079 .064 .051 .025 .020 .017
3.0
.217 .156 .109 .185 .134 .094 .125 .092 .065 .072 .053 .038 .023 .017 .012
4.0
.198 .132 .083 .169 .114 .072 .115 .079 .050 .066 .046 .030 .021 .015 .010
5.0
.181 .114 .065 .155 .098 .056 .106 .068 .040 .061 .040 .023 .020 .013 .008
6.0
.168 .100 .052 .144 .086 .045 .099 .060 .032 .057 .035 .019 .018 .011 .006
7.0
.156 .089 .043 .134 .077 .038 .092 .054 .027 .053 .032 .016 .017 .010 .005
8.0
.146 .080 .036 .125 .070 .032 .086 .049 .022 .050 .029 .013 .016 .009 .004
9.0
.137 .073 .031 .118 .064 .027 .081 .045 .019 .047 .026 .011 .015 .009 .004
10.0
.129 .067 .027 .111 .059 .024 .077 .041 .017 .045 .024 .010 .014 .008 .003
γ Range: 0 - 90DEG γ Interval: 0.5DEG
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:24.6DEG Operators:王 林 飞 Test Date:2010-11-10
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:53% Test Distance:5.400m [K=1.0000] Remarks:
Checker:
Assessor: 张 树
Light Green International Co.Ltd
Page 5 Of 12
Uncorrected UGR Table
ceiling/cavity
0.7
0.7
0.5
0.5
0.3
0.7
0.7
0.5
0.5
0.3
walls
0.5
0.3
0.5
0.3
0.3
0.5
0.3
0.5
0.3
0.3
working plane
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
2H
15.5
17.0
15.7
17.2
17.4
16.0
17.6
16.3
17.8
18.0
3H
16.9
18.3
17.2
18.5
18.7
17.6
19.0
17.9
19.2
19.4
4H
17.4
18.7
17.7
19.0
19.2
18.2
19.5
18.5
19.8
20.0
6H
17.7
18.9
18.0
19.2
19.5
18.6
19.8
18.9
20.1
20.4
8H
17.7
18.9
18.1
19.2
19.5
18.7
19.9
19.0
20.2
20.5
12H
17.7
18.9
18.1
19.2
19.5
18.7
19.9
19.1
20.2
20.5
2H
16.1
17.5
16.5
17.7
18.0
16.6
17.9
16.9
18.2
18.4
3H
17.7
18.9
18.1
19.2
19.5
18.3
19.5
18.7
19.8
20.1
4H
18.3
19.4
18.7
19.7
20.1
19.0
20.1
19.4
20.4
20.7
6H
18.7
19.7
19.1
20.0
20.4
19.6
20.5
20.0
20.8
21.2
Room dimensions x =
2H y =
4H
Viewed crosswise
Viewed endwise
8H
18.8
19.7
19.2
20.1
20.5
19.7
20.6
20.1
21.0
21.4
12H
18.8
19.6
19.3
20.0
20.4
19.8
20.6
20.2
21.0
21.4
8H
4H
18.6
19.5
19.0
19.9
20.3
19.2
20.1
19.6
20.5
20.9
6H
19.2
19.9
19.6
20.3
20.7
19.9
20.6
20.3
21.0
21.5
8H
19.3
20.0
19.8
20.4
20.8
20.2
20.8
20.6
21.2
21.7
12H
19.4
19.9
19.8
20.4
20.8
20.3
20.8
20.8
21.3
21.8
12H
4H
18.6
19.4
19.1
19.8
20.2
19.2
20.0
19.7
20.4
20.8
6H
19.2
19.9
19.7
20.3
20.7
19.9
20.6
20.4
21.0
21.5
8H
19.4
20.0
19.9
20.4
20.9
20.2
20.8
20.7
21.2
21.7
Variations with the observer position at spacings: S = 1.0H
+ 0.2 / - 0.2
+ 0.2 / - 0.2
1.5H
+ 0.2 / - 0.3
+ 0.2 / - 0.3
2.0H
+ 0.2 / - 0.3
+ 0.2 / - 0.3
CIE Pub.117 Corrected 2197 lm Total Lamp Luminous Flux.(8log(F/F0) = 2.7)
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:24.6DEG Operators:王 林 飞 Test Date:2010-11-10
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:53% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 6 Of 12
UTILIZATION FACTORS TABLE
REFLECTANCE Ceiling
0.8
0.8
0.8
0.7
0.7
0.7
0.5
0.5
0.5
0
Walls
0.7
0.5
0.3
0.7
0.5
0.3
0.7
0.5
0.3
0
Working plane
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0
ROOM INDEX
UTILIZATION FACTORS(PERCENT)
k(RI) x RCR = 5
k = 0.60
58
46
39
57
46
39
56
45
39
32
0.80
68
56
49
67
56
49
65
55
48
41
1.00
76
65
58
75
65
58
73
66
57
50
1.25
83
73
66
82
72
65
79
71
65
57
1.50
88
79
72
87
78
71
84
76
70
63
2.00
95
87
80
93
86
80
90
83
78
70
2.50
99
92
86
97
90
85
93
87
83
75
3.00
103
96
90
100
94
89
96
91
87
79
4.00
107
101
96
104
99
95
100
96
92
83
5.00
109
104
100
106
102
99
102
99
96
86
ROOM INDEX According to DIN EN 13032-2 2004
UF(total)
Direct Suspended
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:24.6DEG Operators:王 林 飞 Test Date:2010-11-10
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
SHRNOM = 1.25
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:53% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 7 Of 12
ISOCANDELA DIAGRAM
90
10% 20% 30% 40% 50% 60% 70% 80% 90%
80 70 60
75.69 151.4 227.1 302.8 378.5 454.1 529.8 605.5 681.2
50 40 30
VERTICAL(DEG)
20 10 0
MAX = 756.92 MIN = 371.68 AVG = 629.64 AVG/MAX = 0.83 MIN/MAX = 0.49
-10 -20 -30 -40 -50 -60 -70
Imax:756.9(H-0.5,V0.0) (At:C=180.0,Gamma=0.5)
-80 -90 -90 -80
UNIT: cd -70 -60
-50 -40
-30 -20
-10
0
10
20
30
40
50
60
70
80
90
HORIZONTAL(DEG)
γ Range: 0 - 90DEG γ Interval: 0.5DEG
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:24.6DEG Operators:王 林 飞 Test Date:2010-11-10
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:53% Test Distance:5.400m [K=1.0000] Remarks:
Checker:
Assessor: 张 树
Light Green International Co.Ltd
Page 8 Of 12
AAI Figure
Flux out:1614 lm
3.281ft 1m
21.72,70.32fc 233.7,756.9lx
9.558ft 291.33cm
6.562ft 2m
5.429,17.58fc 58.43,189.2lx
19.12ft 582.65cm
9.843ft 3m
2.413,7.813fc 25.97,84.10lx
28.67ft 873.98cm
13.12ft 4m
1.357,4.395fc 14.61,47.31lx
38.23ft 1165.30cm
16.4ft 5m
0.8686,2.813fc 9.350,30.28lx
47.79ft 1456.63cm
Height
Eavg,Emax
Angle:111.06deg
Diameter
Note:The Curves indicate the illuminated area and the average illumination when the luminaire is at different distance.
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:24.6DEG Operators:王 林 飞 Test Date:2010-11-10
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:53% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 9 Of 12
ISOLUX DIAGRAM
105.0'
52.5'
0.0'
52.5'
105.0'
131.2'
40.00m
105.0'
32.00m
78.7'
24.00m
52.5'
16.00m
26.2'
8.00m
0.0'
0.00m
26.2'
8.00m
52.5'
16.00m
78.7'
24.00m
105.0'
32.00m
3% 0.2269lx 0.02108fc 5% 0.3782lx 0.03513fc 10% 0.7564lx 0.07027fc 30% 2.269lx 0.2108fc
131.2'
50% 3.782lx 0.3513fc
40.00m 32.00m
16.00m
0.00m
16.00m
32.00m
MOUNTING HEIGHT: 33'(10.0m)
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:24.6DEG Operators:王 林 飞 Test Date:2010-11-10
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:53% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 10 Of 12
Average Luminance Table(CIBSE)
Parameter description for average Luminance
Symbol
Value
Unit
Luminance in Azimuth Plane
Bc
refer Table 2
cd/sq.m.
Intensity at angle Gamma in given azimuth plane
I
from data
cd/klm
Number of lamps
N
1
Output of each lamp(initial lumens as specified)
F
2197.17
Multiplying factor
K
1
Luminous area in horizontal plane used in calculations Angle to the downward vertical from light centre
lm
A
0.317
sq.m.
Gamma
from data
deg
Table 1. Calculation parameters for determination of CIBSE LG3:1996 Average Luminance
G
C plane(deg)
deg
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
55
2112 2125 2150 2188 2231 2274 2314 2343 2363 2371 2366 2348 2316 2276 2232 2192 2156 2132 2123
60
2026 2038 2069 2109 2154 2200 2240 2271 2293 2301 2296 2276 2243 2201 2157 2114 2076 2049 2037
65
1917 1934 1964 2006 2055 2102 2146 2178 2199 2207 2202 2182 2147 2106 2061 2015 1976 1946 1933
70
1774 1790 1827 1872 1924 1971 2017 2053 2075 2083 2079 2055 2021 1979 1933 1886 1842 1810 1793
75
1573 1593 1634 1684 1736 1787 1835 1874 1901 1910 1906 1878 1844 1799 1752 1701 1653 1613 1594
80
1272 1244 1344 1402 1461 1522 1574 1613 1641 1650 1646 1621 1589 1544 1487 1429 1372 1234 1294
85
785
633
894
976
1088 1157 1130 981
879
842
883
994
1156 1194 1130 1019 939
670
789
Table 2. Average Luminance(cd/sq.m.) for defined C plane,Gamma angle
CIBSE
Gamma
Category
(deg)
Average Luminance
Patch Luminance
maximum
specified
maximum
specified
calculated
maximum
measured
maximum
Category 1
55 to 90
2371
200
---
500
Category 2
65 to 90
2207
200
---
500
Category 3
75 to 90
1910
200
---
500
Table 3. Tabulation of Average and Patch Luminance(cd/sq.m.) for defined CIBSE categories No match
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:24.6DEG Operators:王 林 飞 Test Date:2010-11-10
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:53% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 11 Of 12
Average Luminance Table(CIBSE)
Parameter description for average Luminance
Symbol
Value
Unit
Luminance in Azimuth Plane
Bc
refer Table 2
cd/sq.m.
Intensity at angle Gamma in given azimuth plane
I
from data
cd/klm
Number of lamps
N
1
Output of each lamp(initial lumens as specified)
F
2197.17
Multiplying factor
K
1
Luminous area in horizontal plane used in calculations Angle to the downward vertical from light centre
lm
A
0.317
sq.m.
Gamma
from data
deg
Table 1. Calculation parameters for determination of CIBSE LG3:2001 Average Luminance
G deg
C plane(deg) 0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
55
2112 2125 2150 2188 2231 2274 2314 2343 2363 2371 2366 2348 2316 2276 2232 2192 2156 2132 2123
60
2026 2038 2069 2109 2154 2200 2240 2271 2293 2301 2296 2276 2243 2201 2157 2114 2076 2049 2037
65
1917 1934 1964 2006 2055 2102 2146 2178 2199 2207 2202 2182 2147 2106 2061 2015 1976 1946 1933
70
1774 1790 1827 1872 1924 1971 2017 2053 2075 2083 2079 2055 2021 1979 1933 1886 1842 1810 1793
75
1573 1593 1634 1684 1736 1787 1835 1874 1901 1910 1906 1878 1844 1799 1752 1701 1653 1613 1594
80
1272 1244 1344 1402 1461 1522 1574 1613 1641 1650 1646 1621 1589 1544 1487 1429 1372 1234 1294
85
785
633
894
976
1088 1157 1130 981
879
842
883
994
1156 1194 1130 1019 939
670
789
Table 2. Average Luminance(cd/sq.m.) for defined C plane,Gamma angle
Average Luminance(cd/sq.m) range
Maximum
(deg)
measured
Maximum limit for screen type & software category used Type I,II screen Type I,II screen Type III screen
Type III screen
Some neg.s'ware
Only pos.s'ware
Some neg.s'ware
Only pos.s'ware
55 to 90
2371
1000
1500
200
500
65 to 90
2207
1000
1500
200
500
Table 3. Tabulation of average luminance(cd/sq.m.) and luminance limits No match
γ Range: 0 - 90DEG γ Interval: 0.5DEG
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:24.6DEG Operators:王 林 飞 Test Date:2010-11-10
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:53% Test Distance:5.400m [K=1.0000] Remarks:
Checker:
Assessor: 张 树
Light Green International Co.Ltd
Page 12 Of 12
Planar Illuminance Curve
Planar Illuminance Curve E(lx) 8
MH = 10 m C0/180 C90/270
7.2
6.4
5.6
4.8
4
3.2
2.4
1.6
0.8
0 -25
-20
-15
-10
-5
0
5
10
15
20
25
Distance(m)
γ Range: 0 - 90DEG γ Interval: 0.5DEG
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:24.6DEG Operators:王 林 飞 Test Date:2010-11-10
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:53% Test Distance:5.400m [K=1.0000] Remarks:
Checker:
Assessor: 张 树
Light Green International Co.Ltd
Page 1 Of 12
LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:230.1V I:0.5750A P:72.80W PF:0.5500
Lamp Flux:4112.89x1 lm
NAME: LED Panel Light
TYPE:natural white
DIM.:
SPEC.:
MFR.: Light-green
SUR.:1.164m*0.265m
DATA OF LAMP
PHOTOMETRIC DATA
LGI-C0612WBA-Q
MODEL
WEIGHT:5KG
Eff: 56.50 lm/W
Imax(cd)
1390
S/MH(C0/180)
1.27
NOMINAL POWER(W)
76
LOR(%)
100.0
S/MH(C90/270)
1.37
RATED VOLTAGE(V)
230
TOTAL FLUX(lm)
4112.9
η UP,DN(C0-180)
0.0,51.9
NOMINAL FLUX(lm)
4112.89
CIE CLASS
DIRECT
η UP,DN(C180-360)
0.0,48.1
LAMPS INSIDE
1
η up(%)
0.0
CIBSE SHR NOM
1.25
TEST VOLTAGE(V)
230.3
η down(%)
100.0
CIBSE SHR MAX
1.35
LUMINOUS INTENSITY DISTRIBUTION DIAGRAM
C0 PLANE ISOLUX DIAGRAM (UNIT:lx) MH(m) 14 18
-/+180 -150
150
22 -120
120
26 30
-90
0
90
300
38
600 -60
900
42 60
UNIT:cd C0/180,113.2° C30/210,114.5° -30 30 1500 C60/240,116.8° 0 C90/270,117.9° AVERAGE BEAM ANGLE(50%):115.6 DEG
1200
34
46 0.0
AAAAAAAAAAAAAAAAAAAAAAAAAAA
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:25.2DEG Operators:王 林 飞 Test Date:2010-11-10
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
17.0 8.30 6.90 5.60 4.20 2.80
1.40 1.10 0.6900 0.5600 0.4200
34.0 S(m)
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:66% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 2 Of 12
ZONAL FLUX DIAGRAM AND LUMINANCE LIMITATION CURVES
ZONAL FLUX DIAGRAM: γ
C0 1384 1368 1341 1303 1254 1193 1120 1035 941.0 838.4 729.2 613.2 494.4 373.6 253.2 138.7 38.97 4.235
5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 DEG
C45 1387 1377 1359 1332 1294 1243 1179 1102 1011 909.9 797.5 678.3 553.8 426.3 299.2 177.0 73.78 0
C90 1390 1386 1375 1358 1328 1288 1229 1157 1067 964.1 848.0 724.5 594.2 459.9 325.7 195.7 52.77 0
C135 1388 1380 1363 1336 1298 1248 1184 1107 1016 915.2 803.0 684.3 559.0 431.1 302.7 180.4 76.89 0
C180 1386 1371 1346 1310 1261 1200 1128 1043 949.3 846.4 735.3 619.0 498.8 376.5 254.6 139.2 35.45 1.922
C225 1384 1370 1348 1314 1267 1208 1135 1049 951.0 844.8 729.7 608.9 482.1 355.5 230.8 117.7 33.06 0
C270 1384 1373 1353 1325 1281 1226 1153 1069 968.4 859.5 738.6 612.6 482.5 351.4 224.6 106.9 20.02 0
γ
C315 1383 1368 1344 1309 1262 1202 1129 1043 944.1 837.7 721.7 600.8 476.4 349.8 226.2 113.2 31.16 0
0- 5 5- 10 10- 15 15- 20 20- 25 25- 30 30- 35 35- 40 40- 45 45- 50 50- 55 55- 60 60- 65 65- 70 70- 75 75- 80 80- 85 85- 90 90- 95 95-100 100-105 105-110 110-115 115-120 120-125 125-130 130-135 135-140 140-145 145-150 150-155 155-160 160-165 165-170 170-175 175-180
Φ zone
33.18 98.72 161.8 220.6 273.1 317.2 350.9 372.4 380.7 375.3 356.4 324.7 281.8 229.8 170.7 108.6 50.88 6.046
LUMINOUS INTENSITY:cd
Φ total
33.18 131.9 293.7 514.3 787.4 1105 1456 1828 2209 2584 2940 3265 3547 3777 3947 4056 4107 4113
%lum,lamp 0.81,0.81 3.21,3.21 7.14,7.14 12.5,12.5 19.1,19.1 26.9,26.9 35.4,35.4 44.4,44.4 53.7,53.7 62.8,62.8 71.5,71.5 79.4,79.4 86.2,86.2 91.8,91.8 96,96 98.6,98.6 99.9,99.9 100,100
UNIT:lm
LUMINANCE LIMITATION CURVES GLARE
CLASS
1.15
A
1.50
B
1.85
C
2.20
D
2.55
E
ILLUMINANCE (lx) 2000
a
G(DEG) 85
a b
c
d
1000
500
2000
1000
500
2000
1000
500
2000
1000
500
<=300
d
2000 e
1000 f
500 g
b
e
f
<=300
c
g
<=300 <=300
<=300 h
h
75
C0/180
C90/270
8 6
85
1449
1963
4
80
2588
3653
3
75
3171
4079
70
3541
4358
65
3792
4557
60
3975
4697
55
4121
4792
50
4228
4862
45
4314
4890
a/h 65
2
55
45
LUMINANCE cd/(m2) G(DEG)
8 1000 C0/180
2
3 4 C90/270
5
6
8
10000
2 3 4 LUMINANCE (cd/(m2))
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:25.2DEG Operators:王 林 飞 Test Date:2010-11-10
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
1
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:66% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 3 Of 12
CU AND LUMINAIRE BUDGETARY ESTIMATE DIAGRAM
ρ cc
80%
ρw
50%
30%
ρ fc
70% 10%
50%
20%
RCR
30%
50% 10%
50%
20%
RCR:Room Cavity Ratio
30%
30% 10%
50%
20%
30%
10% 10%
50%
20%
30%
0 10%
20%
0 0
Coefficients of Utilization(CU)
0.0
1.19 1.19 1.19 1.16 1.16 1.16 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.00
1.0
1.04
.00
.96
1.02
.98
.95
.98
.94
.92
.94
.91
.89
.90
.88
.86
.84
2.0
.91
.84
.78
.89
.83
.77
.85
.80
.75
.82
.78
.74
.79
.75
.72
.70
3.0
.80
.71
.65
.78
.70
.64
.75
.68
.63
.72
.67
.62
.70
.65
.61
.59
4.0
.70
.62
.55
.69
.61
.54
.67
.59
.54
.64
.58
.53
.62
.57
.52
.50
5.0
.63
.54
.47
.62
.53
.47
.60
.52
.46
.58
.51
.46
.56
.50
.45
.43
6.0
.56
.47
.41
.55
.47
.41
.54
.46
.40
.52
.45
.40
.50
.44
.40
.38
7.0
.51
.42
.36
.50
.42
.36
.49
.41
.36
.47
.40
.35
.46
.40
.35
.33
8.0
.47
.38
.32
.46
.38
.32
.45
.37
.32
.43
.37
.32
.42
.36
.31
.30
9.0
.43
.34
.29
.42
.34
.29
.41
.34
.29
.40
.33
.28
.39
.33
.28
.26
10.0
.39
.31
.26
.39
.31
.26
.38
.31
.26
.37
.30
.26
.36
.30
.26
.24
LAMPS 50
LUMINAIRE BUDGETARY DIAGRAM
40 30 H=8 20 7 6 10 9 8 7 6
CONDITIONS FLUX 1000lm FACTOR 0.70
5 H=5
Hdown Hwork
5
0.00m 0.80m
Ework(AVE)
4 4
ρ (%)
cc 70
3 3
50 2 2 10
20
30 40 50
70
100
200 300 AREA(m2)
500 700
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:25.2DEG Operators:王 林 飞 Test Date:2010-11-10
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
1k
2k
100lx w fc 50 30 30
3k 4k 5k
20 7k
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:66% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 4 Of 12
WEC AND CCEC
ρ cc ρw
80% 50%
ρ fc
RCR
30%
70% 10%
50%
20%
30%
50% 10%
50%
20%
30%
30% 10%
50%
20%
RCR:Room Cavity Ratio
30%
10% 10%
50%
20%
30%
0 10%
20%
0 0
Wall Exitance Coeffcients(WEC)
0.0 1.0
.305 .173 .055 .298 .170 .054 .284 .163 .052 .272 .157 .050 .261 .151 .049
2.0
.289 .159 .049 .283 .156 .048 .271 .151 .047 .261 .146 .046 .251 .142 .045
3.0
.269 .143 .043 .263 .141 .042 .253 .137 .042 .243 .133 .041 .235 .130 .040
4.0
.249 .129 .038 .244 .128 .038 .235 .124 .037 .226 .121 .037 .218 .119 .036
5.0
.230 .117 .034 .226 .116 .034 .218 .113 .033 .210 .111 .033 .203 .109 .033
6.0
.214 .107 .031 .210 .106 .031 .203 .104 .030 .196 .102 .030 .190 .100 .030
7.0
.199 .098 .028 .196 .097 .028 .189 .096 .028 .183 .094 .027 .177 .092 .027
8.0
.186 .091 .026 .183 .090 .025 .177 .088 .025 .172 .087 .025 .167 .085 .025
9.0
.174 .084 .024 .172 .084 .023 .166 .082 .023 .161 .081 .023 .157 .080 .023
10.0
.164 .079 .022 .161 .078 .022 .157 .077 .022 .152 .076 .022 .148 .075 .021
ρ cc ρw
80% 50%
ρ fc
RCR
30%
70% 10%
50%
20% RCR:Room Cavity Ratio
30% 20%
50% 10%
50%
30%
30% 10%
20%
50%
30% 20%
10% 10%
50%
30%
0 10%
20%
0 0
Ceiling Cavity Exitance Coefficients(CCEC)
0.0
.190 .190 .190 .163 .163 .163 .111 .111 .111 .064 .064 .064 .020 .020 .020
1.0
.180 .156 .135 .154 .134 .116 .105 .092 .080 .061 .053 .047 .019 .017 .015
2.0
.172 .132 .098 .147 .114 .085 .101 .079 .059 .058 .046 .035 .019 .015 .011
3.0
.164 .114 .074 .141 .099 .065 .097 .068 .045 .056 .040 .027 .018 .013 .009
4.0
.157 .101 .058 .134 .087 .051 .092 .061 .036 .054 .036 .021 .017 .012 .007
5.0
.149 .091 .047 .128 .078 .041 .088 .055 .029 .051 .032 .017 .016 .010 .006
6.0
.142 .082 .039 .122 .071 .034 .084 .050 .024 .049 .029 .014 .016 .010 .005
7.0
.135 .075 .033 .117 .065 .029 .081 .046 .020 .047 .027 .012 .015 .009 .004
8.0
.129 .070 .029 .111 .060 .025 .077 .042 .018 .045 .025 .011 .014 .008 .003
9.0
.123 .065 .025 .106 .056 .022 .073 .039 .016 .043 .023 .009 .014 .008 .003
10.0
.117 .060 .022 .101 .052 .020 .070 .037 .014 .041 .022 .008 .013 .007 .003
γ Range: 0 - 90DEG γ Interval: 0.5DEG
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:25.2DEG Operators:王 林 飞 Test Date:2010-11-10
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:66% Test Distance:5.400m [K=1.0000] Remarks:
Checker:
Assessor: 张 树
Light Green International Co.Ltd
Page 5 Of 12
Uncorrected UGR Table
ceiling/cavity
0.7
0.7
0.5
0.5
0.3
0.7
0.7
0.5
0.5
0.3
walls
0.5
0.3
0.5
0.3
0.3
0.5
0.3
0.5
0.3
0.3
working plane
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
2H
17.9
19.5
18.2
19.7
19.9
18.6
20.2
18.9
20.4
20.6
3H
19.4
20.8
19.7
21.0
21.3
20.3
21.7
20.6
21.9
22.1
4H
19.9
21.3
20.2
21.5
21.8
20.9
22.2
21.2
22.5
22.7
6H
20.2
21.5
20.6
21.8
22.0
21.4
22.6
21.7
22.9
23.2
8H
20.3
21.5
20.6
21.8
22.1
21.5
22.7
21.9
23.0
23.3
12H
20.3
21.4
20.6
21.7
22.0
21.6
22.8
21.9
23.1
23.4
2H
18.7
20.0
19.0
20.2
20.5
19.2
20.5
19.5
20.8
21.0
3H
20.3
21.5
20.6
21.8
22.1
21.0
22.2
21.4
22.5
22.8
4H
20.9
22.0
21.3
22.3
22.7
21.8
22.8
22.2
23.2
23.5
6H
21.3
22.3
21.7
22.6
23.0
22.4
23.3
22.8
23.7
24.0
Room dimensions x =
2H y =
4H
Viewed crosswise
Viewed endwise
8H
21.4
22.3
21.8
22.7
23.1
22.6
23.5
23.0
23.8
24.2
12H
21.4
22.2
21.9
22.6
23.0
22.7
23.5
23.1
23.9
24.3
8H
4H
21.3
22.1
21.7
22.5
22.9
22.0
22.9
22.4
23.3
23.6
6H
21.8
22.5
22.3
23.0
23.4
22.8
23.5
23.2
23.9
24.3
8H
22.0
22.6
22.4
23.0
23.5
23.1
23.7
23.5
24.1
24.6
12H
22.0
22.6
22.5
23.0
23.5
23.2
23.8
23.7
24.2
24.7
12H
4H
21.3
22.1
21.7
22.5
22.9
22.0
22.8
22.4
23.2
23.6
6H
21.9
22.5
22.4
23.0
23.4
22.8
23.4
23.3
23.9
24.3
8H
22.1
22.6
22.6
23.1
23.6
23.1
23.7
23.6
24.1
24.6
Variations with the observer position at spacings: S = 1.0H
+ 0.2 / - 0.2
+ 0.1 / - 0.2
1.5H
+ 0.2 / - 0.3
+ 0.2 / - 0.3
2.0H
+ 0.2 / - 0.3
+ 0.2 / - 0.3
CIE Pub.117 Corrected 4113 lm Total Lamp Luminous Flux.(8log(F/F0) = 4.9)
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:25.2DEG Operators:王 林 飞 Test Date:2010-11-10
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:66% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 6 Of 12
UTILIZATION FACTORS TABLE
REFLECTANCE Ceiling
0.8
0.8
0.8
0.7
0.7
0.7
0.5
0.5
0.5
0
Walls
0.7
0.5
0.3
0.7
0.5
0.3
0.7
0.5
0.3
0
Working plane
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0
ROOM INDEX
UTILIZATION FACTORS(PERCENT)
k(RI) x RCR = 5
k = 0.60
57
46
39
57
45
39
55
45
38
32
0.80
67
56
48
66
55
48
65
55
48
41
1.00
76
65
58
75
64
57
73
66
57
50
1.25
83
73
66
82
72
65
79
71
64
57
1.50
88
78
71
87
77
71
84
76
70
62
2.00
95
87
80
93
85
79
90
83
78
70
2.50
99
91
85
97
90
84
93
87
83
74
3.00
102
96
90
100
94
89
96
91
87
78
4.00
106
101
96
104
99
95
100
96
92
83
5.00
109
104
100
106
102
99
102
99
95
86
ROOM INDEX According to DIN EN 13032-2 2004
UF(total)
Direct Suspended
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:25.2DEG Operators:王 林 飞 Test Date:2010-11-10
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
SHRNOM = 1.25
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:66% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 7 Of 12
ISOCANDELA DIAGRAM
90
10% 20% 30% 40% 50% 60% 70% 80% 90%
80 70 60
139.0 278.0 417.1 556.1 695.1 834.1 973.2 1112 1251
50 40 30
VERTICAL(DEG)
20 10 0
MAX = 1390.2 MIN = 689.22 AVG = 1165.3 AVG/MAX = 0.84 MIN/MAX = 0.50
-10 -20 -30 -40 -50 -60 -70
Imax:1390(H0.0,V-4.0) (At:C=90.0,Gamma=4.0)
-80 -90 -90 -80
UNIT: cd -70 -60
-50 -40
-30 -20
-10
0
10
20
30
40
50
60
70
80
90
HORIZONTAL(DEG)
γ Range: 0 - 90DEG γ Interval: 0.5DEG
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:25.2DEG Operators:王 林 飞 Test Date:2010-11-10
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:66% Test Distance:5.400m [K=1.0000] Remarks:
Checker:
Assessor: 张 树
Light Green International Co.Ltd
Page 8 Of 12
AAI Figure
Flux out:3075 lm
3.281ft 1m
38.35,129.1fc 412.8,1390lx
9.947ft 303.20cm
6.562ft 2m
9.587,32.28fc 103.2,347.5lx
19.89ft 606.39cm
9.843ft 3m
4.261,14.35fc 45.86,154.4lx
29.84ft 909.59cm
13.12ft 4m
2.397,8.070fc 25.80,86.87lx
39.79ft 1212.78cm
16.4ft 5m
1.534,5.165fc 16.51,55.60lx
49.74ft 1515.98cm
Height
Eavg,Emax
Angle:113.18deg
Diameter
Note:The Curves indicate the illuminated area and the average illumination when the luminaire is at different distance.
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:25.2DEG Operators:王 林 飞 Test Date:2010-11-10
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:66% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 9 Of 12
ISOLUX DIAGRAM
105.0'
52.5'
0.0'
52.5'
105.0'
131.2'
40.00m
105.0'
32.00m
78.7'
24.00m
52.5'
16.00m
26.2'
8.00m
0.0'
0.00m
26.2'
8.00m
52.5'
16.00m
78.7'
24.00m
105.0'
32.00m
3% 0.4167lx 0.03871fc 5% 0.6944lx 0.06452fc 10% 1.389lx 0.129fc 30% 4.167lx 0.3871fc
131.2'
50% 6.944lx 0.6452fc
40.00m 32.00m
16.00m
0.00m
16.00m
32.00m
MOUNTING HEIGHT: 33'(10.0m)
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:25.2DEG Operators:王 林 飞 Test Date:2010-11-10
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:66% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 10 Of 12
Average Luminance Table(CIBSE)
Parameter description for average Luminance
Symbol
Value
Unit
Luminance in Azimuth Plane
Bc
refer Table 2
cd/sq.m.
Intensity at angle Gamma in given azimuth plane
I
from data
cd/klm
Number of lamps
N
1
Output of each lamp(initial lumens as specified)
F
4112.89
Multiplying factor
K
1
Luminous area in horizontal plane used in calculations Angle to the downward vertical from light centre
lm
A
0.3085
sq.m.
Gamma
from data
deg
Table 1. Calculation parameters for determination of CIBSE LG3:1996 Average Luminance
G
C plane(deg)
deg
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
55
4121 4175 4258 4353 4454 4556 4652 4723 4773 4792 4781 4738 4672 4584 4487 4392 4297 4216 4155
60
3975 4043 4135 4235 4342 4450 4544 4617 4669 4697 4686 4639 4573 4481 4383 4276 4173 4078 4013
65
3792 3877 3976 4082 4193 4299 4397 4477 4532 4557 4545 4503 4434 4342 4232 4116 4005 3907 3826
70
3541 3643 3752 3867 3984 4098 4199 4280 4334 4358 4349 4309 4243 4143 4027 3902 3756 3654 3569
75
3171 3234 3344 3539 3686 3806 3909 3990 4050 4079 4071 4032 3961 3853 3730 3575 3347 3172 3188
80
2588 2412 2726 3040 3231 3376 3491 3573 3627 3653 3655 3628 3553 3440 3298 3099 2765 2378 2598
85
1449 1399 1916 2299 2643 2816 2723 2322 2050 1963 2079 2379 2816 2929 2762 2422 2002 1400 1318 Table 2. Average Luminance(cd/sq.m.) for defined C plane,Gamma angle
CIBSE
Gamma
Category
(deg)
Average Luminance
Patch Luminance
maximum
specified
maximum
specified
calculated
maximum
measured
maximum
Category 1
55 to 90
4792
200
---
500
Category 2
65 to 90
4557
200
---
500
Category 3
75 to 90
4079
200
---
500
Table 3. Tabulation of Average and Patch Luminance(cd/sq.m.) for defined CIBSE categories No match
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:25.2DEG Operators:王 林 飞 Test Date:2010-11-10
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:66% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 11 Of 12
Average Luminance Table(CIBSE)
Parameter description for average Luminance
Symbol
Value
Unit
Luminance in Azimuth Plane
Bc
refer Table 2
cd/sq.m.
Intensity at angle Gamma in given azimuth plane
I
from data
cd/klm
Number of lamps
N
1
Output of each lamp(initial lumens as specified)
F
4112.89
Multiplying factor
K
1
Luminous area in horizontal plane used in calculations Angle to the downward vertical from light centre
lm
A
0.3085
sq.m.
Gamma
from data
deg
Table 1. Calculation parameters for determination of CIBSE LG3:2001 Average Luminance
G deg
C plane(deg) 0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
55
4121 4175 4258 4353 4454 4556 4652 4723 4773 4792 4781 4738 4672 4584 4487 4392 4297 4216 4155
60
3975 4043 4135 4235 4342 4450 4544 4617 4669 4697 4686 4639 4573 4481 4383 4276 4173 4078 4013
65
3792 3877 3976 4082 4193 4299 4397 4477 4532 4557 4545 4503 4434 4342 4232 4116 4005 3907 3826
70
3541 3643 3752 3867 3984 4098 4199 4280 4334 4358 4349 4309 4243 4143 4027 3902 3756 3654 3569
75
3171 3234 3344 3539 3686 3806 3909 3990 4050 4079 4071 4032 3961 3853 3730 3575 3347 3172 3188
80
2588 2412 2726 3040 3231 3376 3491 3573 3627 3653 3655 3628 3553 3440 3298 3099 2765 2378 2598
85
1449 1399 1916 2299 2643 2816 2723 2322 2050 1963 2079 2379 2816 2929 2762 2422 2002 1400 1318 Table 2. Average Luminance(cd/sq.m.) for defined C plane,Gamma angle
Average Luminance(cd/sq.m) range
Maximum
(deg)
measured
Maximum limit for screen type & software category used Type I,II screen Type I,II screen Type III screen
Type III screen
Some neg.s'ware
Only pos.s'ware
Some neg.s'ware
Only pos.s'ware
55 to 90
4792
1000
1500
200
500
65 to 90
4557
1000
1500
200
500
Table 3. Tabulation of average luminance(cd/sq.m.) and luminance limits No match
γ Range: 0 - 90DEG γ Interval: 0.5DEG
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:25.2DEG Operators:王 林 飞 Test Date:2010-11-10
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:66% Test Distance:5.400m [K=1.0000] Remarks:
Checker:
Assessor: 张 树
Light Green International Co.Ltd
Page 12 Of 12
Planar Illuminance Curve
Planar Illuminance Curve E(lx) 15
MH = 10 m C0/180 C90/270
13.5
12
10.5
9
7.5
6
4.5
3
1.5
0 -25
-20
-15
-10
-5
0
5
10
15
20
25
Distance(m)
γ Range: 0 - 90DEG γ Interval: 0.5DEG
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:25.2DEG Operators:王 林 飞 Test Date:2010-11-10
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:66% Test Distance:5.400m [K=1.0000] Remarks:
Checker:
Assessor: 张 树
Light Green International Co.Ltd
Page 1 Of 12
LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:212.0V I:0.1830A P:20.00W PF:0.6130
Lamp Flux:1131.19x1 lm
NAME: LED Plane Light
TYPE:warm white
DIM.:
SPEC.:
MFR.: Light-green
SUR.:0.27m*0.27m
DATA OF LAMP
PHOTOMETRIC DATA
LGI-C3030IDA-Q
MODEL
WEIGHT:5KG
Eff: 56.56 lm/W
Imax(cd)
403.3
S/MH(C0/180)
1.28
NOMINAL POWER(W)
20
LOR(%)
100.0
S/MH(C90/270)
1.27
RATED VOLTAGE(V)
212
TOTAL FLUX(lm)
1131.2
η UP,DN(C0-180)
0.0,51.6
NOMINAL FLUX(lm)
1131.19
CIE CLASS
DIRECT
η UP,DN(C180-360)
0.0,48.4
LAMPS INSIDE
1
η up(%)
0.0
CIBSE SHR NOM
1.25
TEST VOLTAGE(V)
212.4
η down(%)
100.0
CIBSE SHR MAX
1.35
LUMINOUS INTENSITY DISTRIBUTION DIAGRAM
C0 PLANE ISOLUX DIAGRAM (UNIT:lx) MH(m) 14 18
-/+180 -150
150
22 -120
120
26 30
-90
0
90
90
38
180 -60
270
42 60
UNIT:cd C0/180,112.8° C30/210,111.9° -30 30 450 C60/240,110.7° 0 C90/270,109.8° AVERAGE BEAM ANGLE(50%):111.3 DEG
360
34
46 0.0
AAAAAAAAAAAAAAAAAAAAAAAAAAA
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:23.1DEG Operators:王 林 飞 Test Date:2010-12-16
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
17.0 2.40 2.00 1.60 1.20 0.8100
34.0 S(m) 0.4000 0.3200 0.2000 0.1600 0.1200
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:40% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 2 Of 12
ZONAL FLUX DIAGRAM AND LUMINANCE LIMITATION CURVES
ZONAL FLUX DIAGRAM: γ
C0 401.8 397.7 390.7 380.5 366.7 349.2 327.8 303.1 275.3 244.8 212.0 177.6 142.4 106.8 71.85 39.28 12.77 1.149
5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 DEG
C45 400.9 397.2 391.1 379.4 366.0 348.3 326.8 303.5 275.4 246.9 214.8 182.6 148.0 113.5 79.02 47.02 11.84 0
C90 401.0 398.7 389.2 379.7 363.0 346.3 323.1 300.0 272.0 244.0 212.7 181.5 148.5 115.4 82.57 49.73 0 0
C135 401.1 397.5 391.5 379.8 366.6 348.8 327.3 303.8 275.3 246.3 213.7 181.1 146.7 112.5 78.17 46.47 11.68 0
C180 402.1 398.2 391.4 381.3 367.6 350.0 328.2 302.6 274.2 243.2 210.4 176.2 141.1 105.6 70.69 38.00 11.56 0.2930
C225 399.2 393.8 385.9 372.4 357.2 337.6 314.3 289.1 259.4 229.4 196.2 163.2 129.0 95.14 61.71 33.23 7.096 0
C270 398.4 393.5 381.4 369.3 349.9 330.5 305.2 280.0 250.6 221.2 189.3 157.5 124.4 91.24 60.70 30.16 0 0
γ
C315 399.1 393.5 385.5 371.7 356.4 336.8 313.5 288.6 259.5 230.1 197.5 164.9 130.3 96.01 62.16 33.37 7.079 0
0- 5 5- 10 10- 15 15- 20 20- 25 25- 30 30- 35 35- 40 40- 45 45- 50 50- 55 55- 60 60- 65 65- 70 70- 75 75- 80 80- 85 85- 90 90- 95 95-100 100-105 105-110 110-115 115-120 120-125 125-130 130-135 135-140 140-145 145-150 150-155 155-160 160-165 165-170 170-175 175-180
Φ zone
9.598 28.48 46.50 62.98 77.41 89.12 97.76 102.8 104.3 102.1 96.41 87.46 75.71 61.52 45.74 29.40 12.83 1.075
LUMINOUS INTENSITY:cd
Φ total
9.598 38.08 84.57 147.5 225.0 314.1 411.8 514.7 619.0 721.0 817.4 904.9 980.6 1042 1088 1117 1130 1131
%lum,lamp 0.85,0.85 3.37,3.37 7.48,7.48 13,13 19.9,19.9 27.8,27.8 36.4,36.4 45.5,45.5 54.7,54.7 63.7,63.7 72.3,72.3 80,80 86.7,86.7 92.1,92.1 96.2,96.2 98.8,98.8 99.9,99.9 100,100
UNIT:lm
LUMINANCE LIMITATION CURVES GLARE
CLASS
1.15
A
1.50
B
1.85
C
2.20
D
2.55
E
ILLUMINANCE (lx) 2000
a
G(DEG) 85
a b
c
d
1000
500
2000
1000
500
2000
1000
500
2000
1000
500
<=300
d
2000 e
1000 f
500 g
b
e
f
<=300
c
g
<=300 <=300
<=300 h
h
75
C0/180
8 6
85
2010
0
4
80
3103
3929
3
75
3808
4376
70
4284
4629
65
4621
4819
60
4873
4979
55
5070
5087
50
5223
5206
45
5340
5276
a/h 65
C90/270
2
55
45
LUMINANCE cd/(m2) G(DEG)
8 1000 C0/180
2
3 4 C90/270
5
6
8
10000
2 3 4 LUMINANCE (cd/(m2))
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:23.1DEG Operators:王 林 飞 Test Date:2010-12-16
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
1
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:40% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 3 Of 12
CU AND LUMINAIRE BUDGETARY ESTIMATE DIAGRAM
ρ cc
80%
ρw
50%
30%
ρ fc
70% 10%
50%
20%
RCR
30%
50% 10%
50%
20%
RCR:Room Cavity Ratio
30%
30% 10%
50%
20%
30%
10% 10%
50%
20%
30%
0 10%
20%
0 0
Coefficients of Utilization(CU)
0.0
1.19 1.19 1.19 1.16 1.16 1.16 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02
.00
1.0
1.04 1.00
.96
1.02
.98
.95
.98
.95
.92
.94
.91
.89
.90
.88
.86
.84
2.0
.91
.84
.79
.89
.83
.78
.86
.80
.76
.82
.78
.74
.79
.76
.72
.70
3.0
.80
.72
.65
.78
.71
.65
.75
.69
.64
.73
.67
.63
.70
.65
.61
.59
4.0
.71
.62
.55
.70
.61
.55
.67
.60
.54
.65
.58
.53
.62
.57
.53
.51
5.0
.63
.54
.48
.62
.54
.47
.60
.53
.47
.58
.52
.46
.56
.50
.46
.44
6.0
.57
.48
.42
.56
.48
.41
.54
.47
.41
.53
.46
.41
.51
.45
.40
.38
7.0
.52
.43
.37
.51
.43
.37
.49
.42
.36
.48
.41
.36
.46
.40
.36
.34
8.0
.47
.39
.33
.46
.38
.33
.45
.38
.32
.44
.37
.32
.43
.37
.32
.30
9.0
.43
.35
.29
.43
.35
.29
.41
.34
.29
.40
.34
.29
.39
.33
.29
.27
10.0
.40
.32
.27
.39
.32
.27
.38
.31
.27
.37
.31
.26
.37
.31
.26
.25
LAMPS 50
LUMINAIRE BUDGETARY DIAGRAM
40 30 H=8 20 7
6 10 9 8 7 6
CONDITIONS FLUX 1000lm FACTOR 0.70
5 H=5
Hdown Hwork
5
0.00m 0.80m
Ework(AVE)
4 4
ρ (%)
cc 70
3 3
50 2 2 10
20
30 40 50
70
100
200 300 AREA(m2)
500 700
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:23.1DEG Operators:王 林 飞 Test Date:2010-12-16
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
1k
2k
100lx w fc 50 30 30
3k 4k 5k
20 7k
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:40% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 4 Of 12
WEC AND CCEC
ρ cc ρw
80% 50%
ρ fc
RCR
30%
70% 10%
50%
20%
30%
50% 10%
50%
20%
30%
30% 10%
50%
20%
RCR:Room Cavity Ratio
30%
10% 10%
50%
20%
30%
0 10%
20%
0 0
Wall Exitance Coeffcients(WEC)
0.0 1.0
.301 .171 .054 .294 .167 .053 .280 .161 .051 .268 .155 .050 .257 .149 .048
2.0
.286 .157 .048 .280 .154 .048 .268 .149 .046 .258 .144 .045 .248 .140 .044
3.0
.266 .142 .042 .261 .140 .042 .250 .136 .041 .241 .132 .040 .232 .128 .040
4.0
.246 .128 .038 .242 .126 .037 .232 .123 .037 .224 .120 .036 .216 .117 .036
5.0
.228 .116 .034 .224 .115 .033 .216 .112 .033 .208 .110 .033 .201 .108 .032
6.0
.212 .106 .030 .208 .105 .030 .201 .103 .030 .194 .101 .030 .188 .099 .029
7.0
.198 .098 .028 .194 .097 .028 .188 .095 .027 .182 .093 .027 .176 .091 .027
8.0
.185 .090 .025 .182 .089 .025 .176 .088 .025 .170 .086 .025 .165 .085 .025
9.0
.173 .084 .023 .170 .083 .023 .165 .082 .023 .160 .080 .023 .156 .079 .023
10.0
.163 .078 .022 .160 .078 .022 .156 .076 .021 .151 .075 .021 .147 .074 .021
ρ cc ρw
80% 50%
ρ fc
RCR
30%
70% 10%
50%
20% RCR:Room Cavity Ratio
30% 20%
50% 10%
50%
30%
30% 10%
20%
50%
30% 20%
10% 10%
50%
30%
0 10%
20%
0 0
Ceiling Cavity Exitance Coefficients(CCEC)
0.0
.190 .190 .190 .163 .163 .163 .111 .111 .111 .064 .064 .064 .020 .020 .020
1.0
.180 .156 .135 .154 .134 .116 .105 .092 .080 .061 .053 .047 .019 .017 .015
2.0
.171 .132 .099 .147 .114 .085 .101 .079 .060 .058 .046 .035 .019 .015 .011
3.0
.164 .114 .075 .140 .099 .065 .096 .068 .046 .056 .040 .027 .018 .013 .009
4.0
.156 .101 .059 .134 .087 .051 .092 .061 .036 .053 .036 .021 .017 .012 .007
5.0
.149 .091 .047 .128 .078 .041 .088 .055 .029 .051 .032 .017 .016 .010 .006
6.0
.142 .082 .039 .122 .071 .034 .084 .050 .024 .049 .029 .014 .016 .010 .005
7.0
.135 .075 .033 .116 .065 .029 .080 .046 .021 .047 .027 .012 .015 .009 .004
8.0
.129 .069 .029 .111 .060 .025 .077 .042 .018 .045 .025 .011 .014 .008 .004
9.0
.123 .064 .025 .106 .056 .022 .073 .039 .016 .043 .023 .009 .014 .008 .003
10.0
.117 .060 .022 .101 .052 .020 .070 .037 .014 .041 .022 .008 .013 .007 .003
γ Range: 0 - 90DEG γ Interval: 0.5DEG
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:23.1DEG Operators:王 林 飞 Test Date:2010-12-16
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:40% Test Distance:5.400m [K=1.0000] Remarks:
Checker:
Assessor: 张 树
Light Green International Co.Ltd
Page 5 Of 12
Uncorrected UGR Table
ceiling/cavity
0.7
0.7
0.5
0.5
0.3
0.7
0.7
0.5
0.5
0.3
walls
0.5
0.3
0.5
0.3
0.3
0.5
0.3
0.5
0.3
0.3
working plane
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
2H
18.7
20.2
18.9
20.4
20.6
18.7
20.2
19.0
20.4
20.6
3H
20.1
21.5
20.4
21.7
22.0
20.3
21.7
20.6
21.9
22.1
4H
20.7
22.0
21.0
22.2
22.5
20.9
22.2
21.2
22.5
22.7
6H
21.0
22.2
21.3
22.5
22.8
21.4
22.6
21.7
22.9
23.2
8H
21.1
22.3
21.4
22.5
22.8
21.5
22.7
21.8
22.9
23.2
12H
21.1
22.2
21.4
22.5
22.8
21.4
22.6
21.8
22.9
23.2
2H
19.3
20.6
19.6
20.9
21.1
19.3
20.6
19.6
20.9
21.2
3H
20.9
22.1
21.3
22.4
22.7
21.1
22.2
21.4
22.5
22.8
4H
21.6
22.6
22.0
23.0
23.3
21.8
22.9
22.2
23.2
23.6
6H
22.0
23.0
22.4
23.3
23.7
22.4
23.4
22.8
23.7
24.1
Room dimensions x =
2H y =
4H
Viewed crosswise
Viewed endwise
8H
22.2
23.0
22.6
23.4
23.8
22.6
23.4
23.0
23.8
24.2
12H
22.2
23.0
22.6
23.4
23.8
22.5
23.3
23.0
23.7
24.1
8H
4H
21.9
22.7
22.3
23.1
23.5
22.1
23.0
22.5
23.3
23.7
6H
22.5
23.2
22.9
23.6
24.0
22.8
23.6
23.3
24.0
24.4
8H
22.7
23.3
23.1
23.7
24.2
23.0
23.7
23.5
24.1
24.5
12H
22.8
23.3
23.2
23.8
24.2
23.0
23.6
23.5
24.0
24.5
12H
4H
21.9
22.7
22.3
23.1
23.5
22.1
22.9
22.5
23.3
23.7
6H
22.5
23.2
23.0
23.6
24.0
22.9
23.5
23.3
23.9
24.4
8H
22.8
23.3
23.2
23.7
24.2
23.1
23.6
23.6
24.1
24.6
Variations with the observer position at spacings: S = 1.0H
+ 0.2 / - 0.2
+ 0.1 / - 0.2
1.5H
+ 0.2 / - 0.3
+ 0.2 / - 0.3
2.0H
+ 0.2 / - 0.3
+ 0.2 / - 0.3
CIE Pub.117 Corrected 1131 lm Total Lamp Luminous Flux.(8log(F/F0) = 0.4)
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:23.1DEG Operators:王 林 飞 Test Date:2010-12-16
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:40% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 6 Of 12
UTILIZATION FACTORS TABLE
REFLECTANCE Ceiling
0.8
0.8
0.8
0.7
0.7
0.7
0.5
0.5
0.5
0
Walls
0.7
0.5
0.3
0.7
0.5
0.3
0.7
0.5
0.3
0
Working plane
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0
ROOM INDEX
UTILIZATION FACTORS(PERCENT)
k(RI) x RCR = 5
k = 0.60
58
46
39
57
46
39
56
46
39
33
0.80
68
57
49
67
56
49
65
55
49
42
1.00
77
66
58
75
65
58
73
66
58
50
1.25
84
73
66
82
73
66
80
71
65
58
1.50
89
79
72
87
78
72
84
76
70
63
2.00
95
87
81
94
86
80
90
84
79
71
2.50
99
92
86
97
90
85
94
88
83
75
3.00
103
96
91
101
94
90
97
92
87
79
4.00
107
101
97
104
99
95
100
96
93
84
5.00
109
104
100
107
102
99
102
99
96
87
ROOM INDEX According to DIN EN 13032-2 2004
UF(total)
Direct Suspended
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:23.1DEG Operators:王 林 飞 Test Date:2010-12-16
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
SHRNOM = 1.25
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:40% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 7 Of 12
ISOCANDELA DIAGRAM
90
10% 20% 30% 40% 50% 60% 70% 80% 90%
80 70 60
40.33 80.65 121.0 161.3 201.6 242.0 282.3 322.6 362.9
50 40 30
VERTICAL(DEG)
20 10 0
MAX = 403.26 MIN = 192.46 AVG = 330.78 AVG/MAX = 0.82 MIN/MAX = 0.48
-10 -20 -30 -40 -50 -60 -70
Imax:403.3(H-1.0,V0.0) (At:C=0.0,Gamma=0.0)
-80 -90 -90 -80
UNIT: cd -70 -60
-50 -40
-30 -20
-10
0
10
20
30
40
50
60
70
80
90
HORIZONTAL(DEG)
γ Range: 0 - 90DEG γ Interval: 0.5DEG
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:23.1DEG Operators:王 林 飞 Test Date:2010-12-16
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:40% Test Distance:5.400m [K=1.0000] Remarks:
Checker:
Assessor: 张 树
Light Green International Co.Ltd
Page 8 Of 12
AAI Figure
Flux out:817.4 lm
3.281ft 1m
11.85,37.47fc 127.6,403.3lx
9.345ft 284.83cm
6.562ft 2m
2.963,9.367fc 31.89,100.8lx
18.69ft 569.67cm
9.843ft 3m
1.317,4.163fc 14.17,44.81lx
28.03ft 854.50cm
13.12ft 4m
0.7408,2.342fc 7.973,25.21lx
37.38ft 1139.34cm
16.4ft 5m
0.4741,1.499fc 5.103,16.13lx
46.72ft 1424.17cm
Height
Eavg,Emax
Angle:109.85deg
Diameter
Note:The Curves indicate the illuminated area and the average illumination when the luminaire is at different distance.
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:23.1DEG Operators:王 林 飞 Test Date:2010-12-16
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:40% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 9 Of 12
ISOLUX DIAGRAM
105.0'
52.5'
0.0'
52.5'
105.0'
131.2'
40.00m
105.0'
32.00m
78.7'
24.00m
52.5'
16.00m
26.2'
8.00m
0.0'
0.00m
26.2'
8.00m
52.5'
16.00m
78.7'
24.00m
105.0'
32.00m
3% 0.1210lx 0.01124fc 5% 0.2016lx 0.01873fc 10% 0.4032lx 0.03746fc 30% 1.210lx 0.1124fc
131.2'
50% 2.016lx 0.1873fc
40.00m 32.00m
16.00m
0.00m
16.00m
32.00m
MOUNTING HEIGHT: 33'(10.0m)
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:23.1DEG Operators:王 林 飞 Test Date:2010-12-16
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:40% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 10 Of 12
Average Luminance Table(CIBSE)
Parameter description for average Luminance
Symbol
Value
Unit
Luminance in Azimuth Plane
Bc
refer Table 2
cd/sq.m.
Intensity at angle Gamma in given azimuth plane
I
from data
cd/klm
Number of lamps
N
1
Output of each lamp(initial lumens as specified)
F
1131.19
Multiplying factor
K
1
Luminous area in horizontal plane used in calculations Angle to the downward vertical from light centre
lm
A
0.0729
sq.m.
Gamma
from data
deg
Table 1. Calculation parameters for determination of CIBSE LG3:1996 Average Luminance
G
C plane(deg)
deg
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
55
5070 5092 5122 5137 5145 5136 5128 5102 5088 5087 5091 5106 5125 5115 5115 5100 5082 5051 5031
60
4873 4904 4961 4985 4997 4999 4989 4982 4977 4979 4979 4984 4970 4964 4956 4948 4921 4866 4833
65
4621 4680 4714 4760 4793 4822 4833 4825 4818 4819 4819 4818 4799 4779 4750 4720 4679 4647 4579
70
4284 4340 4412 4475 4535 4571 4603 4624 4627 4629 4625 4597 4558 4526 4495 4436 4376 4297 4235
75
3808 3891 3991 4078 4158 4227 4305 4354 4375 4376 4366 4314 4254 4181 4114 4044 3944 3835 3746
80
3103 3205 3352 3478 3656 3756 3821 3880 3931 3929 3907 3830 3773 3711 3619 3447 3307 3140 3002
85
2010 2209 2477 2568 2147 1560 958
453
118
0
117
447
945
1539 2115 2527 2436 2126 1820
Table 2. Average Luminance(cd/sq.m.) for defined C plane,Gamma angle
CIBSE
Gamma
Category
(deg)
Average Luminance
Patch Luminance
maximum
specified
maximum
specified
calculated
maximum
measured
maximum
Category 1
55 to 90
5145
200
---
500
Category 2
65 to 90
4833
200
---
500
Category 3
75 to 90
4376
200
---
500
Table 3. Tabulation of Average and Patch Luminance(cd/sq.m.) for defined CIBSE categories No match
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:23.1DEG Operators:王 林 飞 Test Date:2010-12-16
γ Range: 0 - 90DEG γ Interval: 0.5DEG
Checker:
Assessor: 张 树
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:40% Test Distance:5.400m [K=1.0000] Remarks:
Light Green International Co.Ltd
Page 11 Of 12
Average Luminance Table(CIBSE)
Parameter description for average Luminance
Symbol
Value
Unit
Luminance in Azimuth Plane
Bc
refer Table 2
cd/sq.m.
Intensity at angle Gamma in given azimuth plane
I
from data
cd/klm
Number of lamps
N
1
Output of each lamp(initial lumens as specified)
F
1131.19
Multiplying factor
K
1
Luminous area in horizontal plane used in calculations Angle to the downward vertical from light centre
lm
A
0.0729
sq.m.
Gamma
from data
deg
Table 1. Calculation parameters for determination of CIBSE LG3:2001 Average Luminance
G deg
C plane(deg) 0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
55
5070 5092 5122 5137 5145 5136 5128 5102 5088 5087 5091 5106 5125 5115 5115 5100 5082 5051 5031
60
4873 4904 4961 4985 4997 4999 4989 4982 4977 4979 4979 4984 4970 4964 4956 4948 4921 4866 4833
65
4621 4680 4714 4760 4793 4822 4833 4825 4818 4819 4819 4818 4799 4779 4750 4720 4679 4647 4579
70
4284 4340 4412 4475 4535 4571 4603 4624 4627 4629 4625 4597 4558 4526 4495 4436 4376 4297 4235
75
3808 3891 3991 4078 4158 4227 4305 4354 4375 4376 4366 4314 4254 4181 4114 4044 3944 3835 3746
80
3103 3205 3352 3478 3656 3756 3821 3880 3931 3929 3907 3830 3773 3711 3619 3447 3307 3140 3002
85
2010 2209 2477 2568 2147 1560 958
453
118
0
117
447
945
1539 2115 2527 2436 2126 1820
Table 2. Average Luminance(cd/sq.m.) for defined C plane,Gamma angle
Average Luminance(cd/sq.m) range
Maximum
(deg)
measured
Maximum limit for screen type & software category used Type I,II screen Type I,II screen Type III screen
Type III screen
Some neg.s'ware
Only pos.s'ware
Some neg.s'ware
Only pos.s'ware
55 to 90
5145
1000
1500
200
500
65 to 90
4833
1000
1500
200
500
Table 3. Tabulation of average luminance(cd/sq.m.) and luminance limits No match
γ Range: 0 - 90DEG γ Interval: 0.5DEG
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:23.1DEG Operators:王 林 飞 Test Date:2010-12-16
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:40% Test Distance:5.400m [K=1.0000] Remarks:
Checker:
Assessor: 张 树
Light Green International Co.Ltd
Page 12 Of 12
Planar Illuminance Curve
Planar Illuminance Curve E(lx) 4.5
MH = 10 m C0/180 C90/270
4.05
3.6
3.15
2.7
2.25
1.8
1.35
0.9
0.45
0 -25
-20
-15
-10
-5
0
5
10
15
20
25
Distance(m)
γ Range: 0 - 90DEG γ Interval: 0.5DEG
C Range: 0 - 360DEG C Interval: 5.0DEG Test Speed: LOW Temperature:23.1DEG Operators:王 林 飞 Test Date:2010-12-16
Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261 Humidity:40% Test Distance:5.400m [K=1.0000] Remarks:
Checker:
Assessor: 张 树