Led a sospensione - Disegni tecnici

Page 1

Specification

Structural features

300*1200 panel light specification

Adopt the solid maintenancefree LED as the light source, with a fast start and long lifespan. Using new catoptric system, high luminance, uniform light. Housing made by imported high hardness alloy, high crash and shock resistance. With a nice appearance, compact and lightweight, easy to install. Cool White, Natural white, Warm white for your chose .

Applications

The special constant current design ensures a stable and reliable working and energy saving. Anti-EMI, CE certification passed . Unleaded, environmental friendly, ROHS approvaled .

RoHS

REACH

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Specification

Applications

300*1200 panel light specification

Widely used at hotel, meeting room, factory, office area, school, hosptial, residential area etc.

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Specification

300*1200 panel light specification Power Parameters

Main technical parameters

No

Item

U nit

V alue

1

input voltage

V

AC100-240

2

frequency

Hz

50/60

3

W

39

V

DC18-24

4

power consumption output voltage

5

PF

>0.9

6

Nti-electric shock rate

â…Ą

Lamp Parameters > 2375 >2 402

cool white

luminous natural white flux warm white

1

Lm

>2 041

cool white

2

natural white

Color Temp

5700-7000 K

4000-5000

warm white

-10~+40

Lx

800(cool white)

operating environment temperature

4

operaing environment humidity

5

centre illumination at 1m

6

net weight

kg

7

dimensions

mm

8 9

certification

CE RoHS UL Gost

Nti-electric shock rate

â…˘

10

Illumination intensity chart

2700-3300 C

3

10-80% 5.4 1198(L)x298(W)x14(H)

w

led power

34+5%

Illumination intensity chart(cool white)

MT Illumination Intensity (UNIT:LX)

1m

800lx

1.5m

355lx

2m 200lx

2.5m 128lx

3m 88lx

height

Eavg,Emax

beam angle:111.71angle

diammeter

PS:The graph above is about lighting area and average illuninance at the different height

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Specification

300*1200 panel light specification

Illumination intensity chart Illumination intensity chart(warm white)

MT Illumination Intensity ( UNIT : LX)

1m

768lx

1.5m

341lx

2m 192lx

2.5m 123lx

3m 85.2lx

height

Eavg,Emax

beam angle: 111.56angle

diammeter

PS:The graph above is about lighting area and average illuninance at the different height

Illumination intensity chart(natural white) MT Illumination Intensity ( UNIT:LX)

1m

936lx

1.5m

416lx

2m 235lx

2.5m 149lx

3m 103.5lx

height

beam angle:110.95angle

diammeter

PS:The graph above is about lighting area and average illuninance at the different height

Electrical connection AC100-277V 50/60HZ

Eavg,Emax

L N

constant current power supply

LEDlamp

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Specification

300*1200 panel light specification

Installation Steps Recessed Installation Method

1. Move the ceiling or dig a 302*1202mm hole at the installnation site. 2. Across the lamp through the opposite angles, then adjust the lamp to the

right position on the front side.

recessed Installation rendering suspended Installation Method

1. Fix the “support” to the ceiling, fix the “lifter” on the “supports” by

the “M4*18round head tapping screws”, as shown. close-up

M4x18screw

lifter

2. Fix the “ceiling accessories ” on the lamp, and threading the “hanging wires”as

the picture shows below. close-up

M4x18screw

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Specification

300*1200 panel light specification

Suspended Installation Method

3. Insert the “hanging wires” through the “ligter” then adjust the height.

Wall mounted method

1. Fix the “mounted holder” on the ceiling by “M5*18 screws”.

2. Fix the “ceiling accessories ” on the lamp, using “M3*5screws”. close-up

M3x5screw

3. Fix the lamp to the “mounted holder”, using “M3*8screws”.

close-up

M3x8screw

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Specification

300*1200 panel light specification

Illuminace comparison Illumination intensity chart of 90W 600*600 grille lamp

1m

667.51lx

800lx

330lx

355lx

166.91lx

200lx

110lx

128lx

1.5m

2m

Illumination intensity chart of 40W 300*1200 LED panle light

2.5m

3m

height

74.171lx Eavg,Emax

beam angle:88.09angle

diammeter height

PS:The graph above is about lighting area and average illuninance at the different height

Energy saving comparison

88lx Eavg,Emax

beam angle: 120angle

diammeter

PS:The graph above is about lighting area and average illuninance at the different height

1 Inductance grille lamp has a beam angle of 88째while 120째 of the LED panle light. Panel lights shine a wide range, the ray of light is more uniform and soft. 2 The luminous flux of 92W grille lamp is 2619LM, the centre luminous flux at 1m is 667LUX while 40W LED panle light has a luminous of 2200LM and 936LUX at the distance of 1m, 129W grill lamp can reach this illumination level. LED panle lights achieve about 69% energy saving when compared with the inductance grill lamp. In the case of 18hours working time per lamp, 365days per year, 365D*18H/D=6570hours We are saving (129-40)w*6570=584730W.H per year.Round downlight has a better light uniformity and energy saving than common energy-saving downlight, it is also more environmentally friendly, and more energy saving to the power grid since its high PF factor. The300*1200 constant current panle light has a PF more than 0.9 while 0.45 of inductance fluorescent lamp, so the LED panle light achieve more than half energy saving than the inductance energy saving lamp.

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Specification

Notice

300*1200 panel light specification

1. Do not use power supply, connecter or other accessories from third party. 2. Never leave children unattended in the vicinity of the lights and do not allow them

to paly with electrical devices. 3. Try to avoid looking directly in the LED beam-especially for extended of time.

FAQ

4.Never allow the light to come into contact with open flames or external heat sources. 5. Prior to cleaning the light, makr sure it has been disconnected from the power supply. 6. Use a dry or slightly moistened cloth for cleaning, never use any chemicals or abrasives for cleaning. 7. Terminal block not included. Installation may require advice from a qualified perso. Terminal block box should have cord anchorage at input and output of the box. 8.Terminal block box should have same IP degree as luminaire. lamps not work reasonďźšLED do not linked to the power well Processing method:Check the power switch, check the power supply,driver, lamp connecting. Any other faults should be performed by trained professionals only.

Effect comparison

LED panle light live view

grille lamp live view

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Specification

Packing

300*1200 panel light specification

quantity weight

2inner box*1pc lamp/inner box=2

pcs/carton

kg/carton

5.4

inner box size (mm)

1302(L)X364(W)X85(H)

outside box size(mm)

1322(L)X384(W)X210(H) inner box outside box

panel light pearl wool 1packe3inner box

outside box

Dimensions

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


SPECIFICATION FOR APPROVAL

Customer Name

:

Product Name :

APPROVED

LGI-C0612

SIGNATURES

Reported By

Audited

by

Approved By

fengchenling LIGHT GREEN INTERNATIONAL CO. ,LTD Building No 6,Block 2,Baiwangxin Industrial Park,Songbai Road, Nanshan District,Shenzhen,Guangdong,China TEL:+86 (0)755 29529100 FAX:+86 (0)755 29529200 http://www.light-green.cn REV:1.2

Page 1 of 7


With less light attenuation and a long life span of 50,000 hours , The light can replace T5 fluorescent lamp,which is much brighter than fluorescent lamp and better than most similar lighting products.

Features : Ø

Energy saved up to 50%. high brightness,even lighting output.

Ø

5-years life time

Ø

Wide range of input voltage: AC100-240V

Ø Instant start, no flickering, no humming Ø New high efficiency constant current driver Ø Special circuit design, each group of LEDs work separately, avoiding any problem of lig hting output caused or influenced by single faulty LED Ø No electrical wave,conforming to CE Ø Green environmental protection, lead-free material, conforming to ROHS Ø No RF interference

Applications: Hotels Conference / Meeting rooms Factories & Offices Commercial Purposes Residential / Institution Buildings Schools, Colleges & Universities Hospitals Places where energy saving and high color rendering index lightings required

Page 2 of 7


MAIN SPECIFICATIONS( T=20℃) NUMBER

ITEM

DESCRIPTION

01

Input Voltage

AC100-240V

02

Power Consumption

74W/42W(RGB)

03

Luminous Flux

04

Color

> 4429 Lm(Cool white) > 4500Lm(natural white) > 3905 Lm(Warm white)

Cool white/Red/Green/Blue/Yellow/Orange / Warm white/ Natural white/RGB

05

Color Temperature

2800-3500K(Warm white) (Natural white)

06

Life Time

07

OperatingTemperature -10℃ to +40℃

08

Storage Temperature

-20℃ to +60℃

09

Humidity Operating

10-80%

10

Humidity Storage

10-80%

11

Luminosity

12

Certifications

CE, RoHS

13

Weight

11KGS

14

Size

598*1198*14mm

15

IK Code

IK04

16

IP Code

IP41

17

Luminaires Class

18

Fixing Ways

5700-7000K(Cool white)

>50,000 Hour

1542Lux(1.0Meter, Cool white) 1305Lux(1.0Meter, Warm white)

Class Ⅲ In-built,Mounting,Suspending

Page 3 of 7

4000-5000K


Light Distribution Graph

Illumination Intensity Chart

LEDs Lumen Attenuationďźš Operating time(hours) 5,000 10,000 20,000 50,000 Page 4 of 7

Lumen decrease(%) 2.4 5.2 11.3 24.5


Dimensions:

Notes: 1. All dimension units are millimeters. 2. All dimension tolerance is ±0.5mm unless otherwise noted.

Packing Inner Carton : 1316*681*79mm (1pcs/carton) Outer Carton: 1336*701*190mm(2pcs/carton) Net weight of each piece: 11kg Quantity:

2PCS/CTN

Page 5 of 7


Safety Notice for Using: .Please always use the light out of its package. . Before starting use of the light, please check if the light was damaged during transportation. If any damage shown, please DO not install or use it. . Any maintenance should be performed by trained professionals only. Keep packaging material away from the reach of children and pets.Risk of suffocation! Caution. The packaging contains small parts that may be swallowed by children. Never leave children unattended in the vicinity of the lights and do not allow them to play with electrical devices. Try to avoid looking directly in the LED beam-especially for extended periods of time. Do not shine the LED light in another person's eyes. Never cover the lights by other objects. Never allow the light to come into contact with open flames or external heat sources.  The products need to re-repair inspection or special treatment of retirement after service time

Maintenance : Prior to cleaning the light, make sure it has been disconnected form the power supply. Use a dry or slightly moistened cloth for cleaning. Never use any chemicals or abrasives for cleaning Disposal: Used electronic devices must be collected for recycling and cannot be deposited together with daily garbage. Installation: This product should be installed by trained electricians. check integrality of the products when unpack the packing. The distance between the light and any flammable materials must not be less than 0.2m. The distance between the upper part of the installed light and the ceiling must not be less than2 cm.The light must not be installed into ceilings or walls that contain heat-insulating material. The main cable must not connect with the low voltage cable or the surfacemounted lights. Guide the lights' connecting cables through the drilled-out hole,and fix the surface-mounted Page 6 of 7


lights with the pre-fitted clips. Make sure that these are securely connected to the base material.

W hen laying the cables, make sure that the cables and plugs are not subjected to any tensileor twisting forces. Fit the cable tension relieving mechanisms to the connection points of thesurface-mounted lights. Do not kink cables. Output cables should be laid separately and at a distance from other cables. After installation, connect the transformer to the mains supply. Proceed by connecting the wiring cables to the luminaries. Usually, the brown (or black) wire is the Live wire, connect it with the terminal marked "L". The blue wire is Naughty wire, connect it with the terminal marked "N". Use only the LED drover included, and do not connect the surface-mounted lights to other loads. .Do not remove the name plate of the power suply and driver of the light. Notes: Non-professionals are not allowed to disassemble and maintain the products.We have the right not to provide after-slae service if unauthorized disassembly and maintenance happens to the products.

Page 7 of 7


Specification

Structural features

600*600 panel light specification

Adopt the solid maintenancefree LED as the light source, with a fast start and long lifespan. Using new catoptric system, high luminance, uniform light. Housing made by imported high hardness alloy, high crash and shock resistance. With a nice appearance, compact and lightweight, easy to install. Cool White, Natural white, Warm white for your chose .

Applications

The special constant current design ensures a stable and reliable working and energy saving. Anti-EMI, CE certification passed . Unleaded, environmental friendly, ROHS approvaled .

RoHS

REACH

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Specification

Applications

600*600 panel light specification

Widely used at hotel, meeting room, factory, office area, school, hosptial, residential area etc.

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Specification

600*600 panel light specification Power Parameters

Main technical parameters

No

Item

U nit

V alue

1

input voltage

V

AC100-240

2

frequency

Hz

50/60

3

power consumption output voltage

W

39

V

DC18-24

4 5

PF

>0.9

6

Nti-electric shock rate

â…Ą

Lamp Parameters 2384

cool white

1

luminous natural white flux warm white

2 402

Lm

20 45

cool white

2

natural white

Color Temp

5700-7000 K

4000-5000

warm white

C

-10~+40

Lx

1072(cool white)

operating environment temperature

4

operaing environment humidity

5

centre illumination at 1m

6

net weight

kg

7

dimensions

mm

8 9

certification

10

Illumination intensity chart

2700-3300

3

10-80% 4.7 598(L)x598(W)x14(H) CE RoHS UL Gost â…˘

Nti-electric shock rate

w

led power

34+5%

Illumination intensity chart(cool white) MT Illumination Intensity (UNIT:LX)

1m

1.5m

1072lx

476lx

2m 268lx

2.5m 172lx

3m 119lx

beam angle:120angle Eavg,Emax height diammeter PS:The graph above is about lighting area and average illuninance at the different height

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Specification

600*600 panel light specification

Illumination intensity chart Illumination intensity chart(warm white) MT Illumination Intensity ( UNIT : LX)

1m

993lx

1.5m

441lx

2m 248lx

2 .5 m 159lx

3m 110lx

height

Eavg,Emax

beam angle:120angle

diammeter

PS:The graph above is about lighting area and average illuninance at the different height

Illumination intensity chart(natural white) MT Illumination Intensity ( UNIT:LX)

1m

1037lx

1.5m

460lx

2m 259lx

2 .5 m 165lx

3m 115lx

height

Eavg,Emax

diammeter beam angle: 120angle PS:The graph above is about lighting area and average illuninance at the different height

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Specification

600*600 panel light specification

Electrical connection AC100-277V 50/60HZ

L N

constant current power supply

LEDlamp

598

598

Dimension

Installation Steps Recessed Installation Method

1. Move the ceiling or dig a 602*602mm hole at the installnation site. 2. Across the lamp through the opposite angles, then adjust the lamp to the

right position on the front side.

recessed Installation rendering Suspended Installation Method

1. Fix the “support” to the ceiling, fix the “lifter” on the “supports” by

the “M4*18round head tapping screws”, as shown.

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Specification

600*600 panel light specification

close-up

M4x18screw

lifter

2 Fix the “ceiling accessories ” on the lamp, and threading the “hanging wires”as

the picture shows below. close-up

M3x5screw

Suspended Installation Method

3. Insert the “hanging wires” through the “ligter” then adjust the height.

Wall mounted method

1. Fix the “mounted holder” on the ceiling by “M5*18 screws”.

M4x18screw

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Specification

600*600 panel light specification

2. Fix the “ceiling accessories ” on the lamp, using “M3*5screws”. close-up

M3x5screw

3. Fix the lamp to the “mounted holder”, using “M3*8screws”.

close-up

M3x8screw

Illuminace comparison Illumination intensity chart of 90W 600*600 grille lamp

1m

667.51lx

Illumination intensity chart of 40W 600*600 LED panle light

1m

1072lx

1.5m

1.5m

476lx

330lx

2m

2m

268lx

166.91lx

2 .5m

2.5m

172lx

110lx

3m

3m

119lx

74.171lx

height

Eavg,Emax

beam angle:88.09angle

diammeter

PS:The graph above is about lighting area and average illuninance at the different height

height

Eavg,Emax

beam angle: 120angle

diammeter

PS:The graph above is about lighting area and average illuninance at the different height

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Specification

Energy saving comparison

600*600 panel light specification

1 Inductance grille lamp has a beam angle of 88°while 120° of the LED panle light. Panel lights shine a wide range, the ray of light is more uniform and soft. 2 The luminous flux of 92W grille lamp is 2947LM, the centre luminous flux at 1m is 667LUX while 40W LED panle light has a luminous of 2947LM and 1072LUX at the distance of 1m, 151W grill lamp can reach this illumination level. LED panle lights achieve about 73% energy saving when compared with the inductance grill lamp. In the case of 18hours working time per lamp, 365days per year, 365D*18H/D=6570hours We are saving (151-40)w*6570=729270W.H per year.Round downlight has a better light uniformity and energy saving than common energy-saving downlight, it is also more environmentally friendly, and more energy saving to the power grid since its high PF factor. The 600*600 constant current panle light has a PF more than 0.9 while 0.45 of inductance fluorescent lamp, so the LED panle light achieve more than half energy saving than the inductance energy saving lamp.

Notice

FAQ

1. Do not use power supply, connecter or other accessories from third party. 2 . Never leave children unattended in the vicinity of the lights and do not allow them to paly with electrical devices. 3 . Try to avoid looking directly in the LED beam-especially for extended of time. 4 . Never allow the light to come into contact with open flames or external heat sources. 5 . Prior to cleaning the light, makr sure it has been disconnected from the power supply. 6 . Use a dry or slightly moistened cloth for cleaning, never use any chemicals or abrasives for cleaning. 7.Terminal block not included. Installation may require advice from a qualified perso. Terminal block box should have cord anchorage at input and output of the box. 8.Terminal block box should have same IP degree as luminaire. lamps not work reason:LED do not linked to the power well Processing method:Check the power switch, check the power supply,driver, lamp connecting. Any other faults should be performed by trained professionals only.

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Specification

600*600 panel light specification

Effect comparison

LED panle light live view

grille lamp live view

Packing

4pcs in a carton quantity weight

pcs/carton

kg/carton

inner box size (mm) outside box size(mm)

4inner box*1pc lamp/inner box=4

22 714(L)X676(W)X62(H) 740(L)X700(W)X280(H)

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Specification

600*600 panel light specification

pearl wool

panel light

inner box

1install4inner box

outside box

top cover

inner box inner box inner box inner box

power supply lamp

pearl wool

bottom cover

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Specification

Structural features

300Ă—300mm led panel light specification

Adopt the solid maintenancefree LED as the light source, with a fast start and long lifespan. Using new catoptric system, high luminance, uniform light. Housing made by imported high hardness alloy, high crash and shock resistance. With a nice appearance, compact and lightweight, easy to install. Cool White, Natural white, Warm white for your chose .

Applications

The special constant current design ensures a stable and reliable working and energy saving. Anti-EMI, CE certification passed . Unleaded, environmental friendly, ROHS approvaled .

RoHS

REACH

TEL :+86-75 5 - 2 9 5 2 9100 FAX :+86-755 - 2 9 5 2 9 200 WEBSITE : www. light-green. cn

E-mail:info@light-green.cn Addressďźš KaiXinDa Industrial Park, ZhoushiRoad No49, BaoAn District, Shenzhen, China


Applications

Widely used at hotel, meeting room, factory, office area, school, hosptial, residential area etc.

TEL :+86-75 5 - 2 9 5 2 9100 FAX :+86-755 - 2 9 5 2 9 200 WEBSITE : www. light-green. cn

E-mail:info@light-green.cn Addressďźš KaiXinDa Industrial Park, ZhoushiRoad No49, BaoAn District, Shenzhen, China


Power Parameters Main technical parameters

U nit

V alue

input voltage

V

AC100-240

2

frequency

Hz

50/60

3

W

19

4

power consumption output voltage

V

DC18-24

5

PF

>0.9

6

Nti-electric shock rate

No

Item

1

Lamp Parameters 1200±5%

cool white

luminous natural white flux warm white

1

1070±5%

cool white

2

natural white

Color Temp

5700-7000 K

warm white

3

operating environment temperature

4

operaing environment humidity

5

centre illumination at 1m

1250±5%

Lm

4000-5000 2700-3300

C

-10~+40

Lx

463(cool white)

10-80%

6

net weight

kg

7

dimensions

mm

8 9

certification

298(L)x298(W)x14(H) CE RoHS UL Gost

Nti-electric shock rate

10

w

led power

Illumination intensity chart(cool white)

1.5

17+5% MT Illumination Intensity ( UNIT : LX)

Illumination intensity chart 1m

463lx

1.5m

239lx

2m 115lx

2.5m 85lx

3m 52lx

height

Eavg,Emax

beam angle:109.85angle

diammeter

PS:The graph above is about lighting area and average illuninance at the different height

TEL :+86-75 5 - 2 9 5 2 9100 FAX :+86-755 - 2 9 5 2 9 200 WEBSITE : www. light-green. cn

E-mail:info@light-green.cn Address: KaiXinDa Industrial Park, ZhoushiRoad No49, BaoAn District, Shenzhen, China


Illumination intensity chart

Illumination intensity chart(warm white) MT Illumination Intensity ( UNIT : LX)

1m

407lx

1.5m

180lx

2m 102lx

2 .5 m 65lx

3m 45lx

height

Eavg,Emax

beam angle:112.13angle

diammeter

PS:The graph above is about lighting area and average illuninance at the different height

Illumination intensity chart(natural white) MT Illumination Intensity ( UNIT : LX)

1m

493lx

1.5m

218lx

2m 123lx

2 .5 m 79lx

3m 55lx

height

Eavg,Emax

beam angle:110.40angle

diammeter

PS:The graph above is about lighting area and average illuninance at the different height

TEL :+86-75 5 - 2 9 5 2 9100 FAX :+86-755 - 2 9 5 2 9 200 WEBSITE : www. light-green. cn

E-mail:info@light-green.cn Addressďźš KaiXinDa Industrial Park, ZhoushiRoad No49, BaoAn District, Shenzhen, China


Electrical connection

AC100-277V 50/60HZ

L N

constant current power supply

LEDlamp

Dimension

TEL :+86-75 5 - 2 9 5 2 9100 FAX :+86-755 - 2 9 5 2 9 200 WEBSITE : www. light-green. cn

E-mail:info@light-green.cn Addressďźš KaiXinDa Industrial Park, ZhoushiRoad No49, BaoAn District, Shenzhen, China


Installation Steps Recessed Installation Method 1. Move the ceiling or dig a 302*302mm hole at the installnation site. 2. Across the lamp through the opposite angles, then adjust the lamp to the right position on the front side.

recessed Installation rendering Suspended Installation Method1. ix the “support” to the ceiling, fix the “lifter” on the “supports” by the “M4*18round head tapping screws”, as shown. close-up

M4x18screw

lifter

2. Fix the “ceiling accessories ” on the lamp, and threading the “hanging wires”as

the picture shows below. close-up

M4x18screw

TEL :+86-75 5 - 2 9 5 2 9100 FAX :+86-755 - 2 9 5 2 9 200 WEBSITE : www. light-green. cn

E-mail:info@light-green.cn Address: KaiXinDa Industrial Park, ZhoushiRoad No49, BaoAn District, Shenzhen, China


3. Insert the “hanging wires” through the “ligter” then adjust the height. Suspended Installation Method

Wall mounted method

1. Fix the “mounted holder” on the ceiling by “M5*18 screws”.

M4x18screw

2. Fix the “ceiling accessories ” on the lamp, using “M3*5screws”. close-up

M3x5screw

3. Fix the lamp to the “mounted holder”, using “M3*8screws”. close-up

M3x5screw

TEL :+86-75 5 - 2 9 5 2 9100 FAX :+86-755 - 2 9 5 2 9 200 WEBSITE : www. light-green. cn

E-mail:info@light-green.cn Address: KaiXinDa Industrial Park, ZhoushiRoad No49, BaoAn District, Shenzhen, China


Notice

FAQ

1. Do not use power supply, connecter or other accessories from third party. 2. Never leave children unattended in the vicinity of the lights and do not allow

them to paly with electrical devices. 3. Try to avoid looking directly in the LED beam-especially for extended of time. 4. Never cover the lights by other objects.Never allow the light to come into contact with open flames or external heat sources. 5. Prior to cleaning the light, makr sure it has been disconnected from the power supply. 6. Use a dry or slightly moistened cloth for cleaning, never use any chemicals or abrasives for cleaning. 7. Terminal block not included. Installation may require advice from a qualified perso. Terminal block box should have cord anchorage at input and output of the box. 8.Terminal block box should have same IP degree as luminaire. lamps not work: reason:LED do not linked to the power well Processing method:Check the power switch, check the power supply,driver, lamp connecting. Any other faults should be performed by trained professionals only.

Effect comparison

LED panle light live view

grille lamp live view

TEL :+86-75 5 - 2 9 5 2 9100 FAX :+86-755 - 2 9 5 2 9 200 WEBSITE : www. light-green. cn

E-mail:info@light-green.cn Address: KaiXinDa Industrial Park, ZhoushiRoad No49, BaoAn District, Shenzhen, China


Packing

panel light

quantit

pcs/carton

weight

kg/carton

4inner box*1pc lamp/inner box=4

7.5

inner box size(mm)

414(L)X376(W)X62(H)

outside box size(mm)

430(L)X400(W)X280(H)

pearl wool

inner box

4pcs in a carton

outside box

TEL :+86-75 5 - 2 9 5 2 9100 FAX :+86-755 - 2 9 5 2 9 200 WEBSITE : www. light-green. cn

E-mail:info@light-green.cn Address: KaiXinDa Industrial Park, ZhoushiRoad No49, BaoAn District, Shenzhen, China


Specification

Structural features

300*600 panel light specification

Adopt the solid maintenancefree LED as the light source, with a fast start and long lifespan. Using new catoptric system, high luminance, uniform light. Housing made by imported high hardness alloy, high crash and shock resistance. With a nice appearance, compact and lightweight, easy to install. Cool White, Natural white, Warm white for your chose .

Applications

The special constant current design ensures a stable and reliable working and energy saving. Anti-EMI, CE certification passed . Unleaded, environmental friendly, ROHS approvaled .

RoHS

REACH

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Specification

Applications

300*600 panel light specification

Widely used at hotel, meeting room, factory, office area, school, hosptial, residential area etc.

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Specification

300*600 panel light specification Power Parameters

Main technical parameters

No

Item

U nit

V alue

1

input voltage

V

AC100-240

2

frequency

Hz

50/60

3

W

26

V

DC18-24

4

power consumption output voltage

5

PF

>0.9

6

Nti-electric shock rate

â…Ą

Lamp Parameters >1 59 4

cool white

1

luminous natural white flux warm white

>1 385

cool white

2

natural white

Color Temp

5700-7000 K

warm white

4000-5000 2700-3300

C

-10~+40

Lx

581(cool white)

3

operating environment temperature

4

operaing environment humidity

5

centre illumination at 1m

6

net weight

kg

7

dimensions

mm

8 9

certification

CE RoHS UL Gost

Nti-electric shock rate

â…˘

10

Illumination intensity chart

>16 15

Lm

10-80%

w

led power

2.3 598(L)x298(W)x14(H)

24+5%

Illumination intensity chart(cool white)

MT Illumination Intensity (UNIT:LX)

1m

505lx

1.5m

224lx

2m 126lx

2.5m 81lx

3m 56lx

height

Eavg,Emax

beam angle: 110.27angle

diammeter

PS:The graph above is about lighting area and average illuninance at the different height

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Specification

300*600 panel light specification

Illumination intensity chart Illumination intensity chart(warm white) MT Illumination Intensity ( UNIT : LX)

1m

402lx

1.5m

179lx

2m 100lx

2 .5 m 64lx

3m 45lx Eavg,Emax beam angle :1 11 .6 3 angle diammeter height PS:The graph above is about lighting area and average illuninance at the different height

Illumination intensity chart(natural white) MT Illumination Intensity ( UNIT:LX)

1m

597lx

1.5m

265lx

2m 149lx

2 .5 m 95lx

3m 66lx

height

Eavg,Emax

beam angle :1 10 .2 5 angle

diammeter

PS:The graph above is about lighting area and average illuninance at the different height

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Specification

300*600 panel light specification

Electrical connection AC100-277V 50/60HZ

L N

constant current power supply

LEDlamp

Dimension

Advantages

Achieves a more energy saving and uniformity of the lights, high PF factor.

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Specification

300*600

panel light specification

Installation Steps Recessed Installation Method

1. Move the ceiling or dig a 302*602mm hole at the installnation site. 2. Across the lamp through the opposite angles, then adjust the lamp to the

right position on the front side.

Suspended Installation Method

1. Fix the “support” to the ceiling, fix the “lifter” on the “supports” by

the “M4*18round head tapping screws”, as shown.

2. Fix the “ceiling accessories ” on the lamp, and threading the “hanging wires”as

the picture shows below.

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Specification

300*600

panel light specification

Installation Steps Recessed Installation Method

3. Insert the “hanging wires” through the “ligter” then adjust the height.

Wall mounted method

1. Fix the “mounted holder” on the ceiling by “M5*18 screws”.

2. Fix the “ceiling accessories ” on the lamp, using “M3*5screws”.

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Specification

Wall mounted method

300*600 panel light specification

3. Fix the lamp to the “mounted holder”, using “M3*8screws”.

1. Do not use power supply, connecter or other accessories from third party. 2. Never leave children unattended in the vicinity of the lights and do not

Notice

allow them to paly with electrical devices. 3. Try to avoid looking directly in the LED beam-especially for extended of time. 4. Never allow the light to come into contact with open flames or external heat sources. 5. Prior to cleaning the light, makr sure it has been disconnected from the power supply. 6. Use a dry or slightly moistened cloth for cleaning, never use any chemicals

or abrasives for cleaning. 7.Terminal block not included. Installation may require advice from a qualified perso. Terminal block box should have cord anchorage at input and output of the box. 8.Terminal block box should have same IP degree as luminaire. FAQ

lamps not work: reason:LED do not linked to the power well Processing method:Check the power switch, check the power supply, driver,lamp connecting. Any other faults should be performed by trained professionals only.

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Specification

300*600 panel light specification

Illuminace comparison Illumination intensity chart of 90W 600*600 grille lamp

1m

667.51lx

1.5m

330lx

Illumination intensity chart of 40W 300*600 LED panle light

1m

505lx

1.5m

224lx

2m

2m

126lx

166.91lx

2.5m

2.5m

81lx

110lx 3m 56lx

3m

height

74.171lx Eavg,Emax

beam angle:88.09angle

diammeter

PS:The graph above is about lighting area and average illuninance at the different height

Energy saving comparison

height

Eavg,Emax

beam angle:120angle

diammeter

PS:The graph above is about lighting area and average illuninance at the different height

1 Inductance grille lamp has a beam angle of 88째while 120째 of the LED panle light. Panel lights shine a wide range, the ray of light is more uniform and soft. 2 The luminous flux of30W grille lamp is 119LM, the centre luminous flux at 1m is 1903LUX while 22W LED panle light has a luminous of 1260LM and 686LUX at the distance of 1m, 173W grill lamp can reach this illumination level. LED panle lights achieve about 87% energy saving when compared with the inductance grill lamp. In the case of 18hours working time per lamp, 365days per year, 365D*18H/D=6570hours We are saving (173-22)w*6570=992070W.H per year.Round downlight has a better light uniformity and energy saving than common energy-saving downlight, it is also more environmentally friendly, and more energy saving to the power grid since its high PF factor. The 300*600 constant current panle light has a PF more than 0.9 while 0.45 of inductance fluorescent lamp, so the LED panle light achieve more than half energy saving than the inductance energy saving lamp.

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Specification

300*600 panel light specification

Effect comparison

LED panle light live view

grille lamp live view

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Specification

Packing

300*600 panel light specification

quantity weight

pcs/carton

4inner box*1pc lamp/inner box=4

kg/carton

12

inner box size (mm)

714(L)X376(W)X62(H)

outside box size(mm)

736(L)X400(W)X280(H)

panel light power supply pearl wool

inner box

4pcs in a carton

outside box

TEL:+86-755-29529100 FAX:+86-755-29529200 WEBSITE:www.light-green.cn

E-mail:info@light-green.cn Address:KaiXinDa Industrial Park,ZhoushiRoad No49,BaoAn District,Shenzhen,China


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.