DESIGN PORTFOLIO - SWEETY SHAH

Page 1

DESIGN PORTFOLIO Sweety Shah

WW
1. SKYSCAPE CONDOS__________________________________________________________________________ 2. THE C.U.B.E AT THE METZ______________________________________________________________________ 3. GREEN CITY AFFORDABLE HOUSING_____________________________________________________________ 4. CIRCO ENVIRONMENTAL AWARENESS CENTRE____________________________________________________ 5. MISCELLANEOUS : SKETCHING, PHOTOGRAPHY & CREATIVE DESIGN MODELLING_______________________ 6. WORKING DRAWINGS SET : 3517 DUPLEXES BP SET-VECTORWORKS__________________________________ SKYSCAPE CONDOS - REVIT_____________________________________________ WINDMERE TOWNHOUSES-AUTOCAD____________________________________ TABLE OF CONTENTS

Use of bricks, acm panels and curtain wall gives a modern and chic look to the building. The concept of design was to layout every unit in a way to give them best views and 2 open facades along with maintaing the privacy between units. Penthouses have sloping roofs creating double heighted ceilings to add more light and create luxuruious space.

01. SKYSCAPE CONDOS MIXED USE BUILDING: RESTAURANT, BAR & HIGH RISE CONDOMINIUMS SOFTWARE USED: REVIT 2020

This mixed use building with a restaurant, boutique hotel and a spa for Auburn Developments in Kitchener, Ontario. The site already had an existing 1 storey building, and the bricks were to be retained and re-used as much possible.

The concept of the building was to have maximized views on South-West facades creating interesting, distinctive, and inviting entrance with the use of green roofs. The site is surrounded by historical buildings, so I wanted to create modern yet keeping the facades historical so that the building blended well. By using brick and having huge arch shaped openings and curtain wall satisfies the context but the green roofs and use of curtain wall gives a modern and chic look to the building.

02. THE C.U.B.E AT THE METZ MIXED USE BUILDING: RESTAURANT, SPA & BOUTIQUE HOTEL SOFTWARE USED: REVIT 2019

GREEN CITY

The design program was to design an affordable housing in Ahmedabad, India.

The housing clusters were designed while keeping in mind the space planning of the low and middle-income group housing. This studio exercise was design proposal for goverment to address the housing market and make it affordable for everyone.

The basic concept for the design was creating a visual connection and sharing more common spaces for social interaction throughout the day.

The suites were tilted around at an angle in order to achieve maximum vision and have an added face for openings, also increasing cross ventilation in the space.

03.
HOUSING LOW INCOME AFFORDABLE HOUSING B.ARCH-SEMESTER VI SOFTWARE USED: AUTOCAD, SKETCHUP

The design program was to design an educational institutional building. We had to choose from three different sites and design a building that respects the site context and existing surrounding. The site I chose had a beautiful hill backdrop, and hence I decided to design an Environmental Awareness Centre. The concept for the design was to build a subdued building to not block the view for people living there with high rise construction. Lifting up the library and a refreshment area for employees to give a beautiful view. The structure was in a concept of a tree, a staircase leading to a circular space with balcony all around.

04. ENVIROMENTAL AWARENESS CENTRE INSTITUTIONAL BUILDING: B.ARCH: SEM II HAND DRAFTING
05. MISCELLANEOUS SKETCHING, CREATIVE DESIGN MODELLING
1. 3517 Duplexes BP Set - Vectorworks 2. Skyscape Condos - Revit 3. Windmere Townhouses - Autocad 06.WORKING DRAWINGS SET

SITECOVERAGE:

IMPERMEABLEAREA.:

HEIGHT:

FRONTYARD:

SIDEYARDS:

REARYARDS:

BUILDINGDEPTH:

ALLOWABLEFLOORSPACERATIO:

MAX

MAX

PROPOSEDF.S.R.:

THIRDSTOREY

THIRDSTOREY

SECONDSTOREY

FIRSTSTOREY

FIRSTSTOREY

FIREPLACE&BAYWINDOWOVERAGE

SLOPEDROOFEXCLUSION(1.2-2.3M)

TOTALAREA

FIREPLACE&BAYWINDOWAREA:

ENTRIES PORCHES VERANDAHSAREA:

SLOPEDROOF(1.2M-2.3M)AREA:

ACCESSORYBUILDING GARAGE

GBSENGINEERINGGROUPLTD #14329HawkstreamDr

PortMoody

MYCORRHIZAURBANFORESTRY 1617783Ave Surrey BCV4N5T3 Phone:(778)222-6767

DOMUSHOMEENERGYINC 1556E5thAve#101 Vancouver BCV5N1L7 Phone:604-243-8616

SITESTATISTICS:3517W23RDAVE LEGALDESCRIPTION: LOT15BLOCK26PLANVAP4576DISTRICTLOT139NWDOFLOT CIVICADDRESS: 3517WEST23RDAVENUEVANCOUVERV6S1K4 ZONING: RS-5ONEFAMILYDWELLING SITEDIMENSIONS: 32.99' X122.21' SITEAREA: 4,031.71sq.ft 374.55sq.m.]
MAX ALLOWED:[4.3.1] 35.10' 10.7M &notmorethan 1/2storeys PROPOSED &envelopeheightof30.18' 9.2M
MIN REQUIRED:[4.4.1] 24.44' 20%ofsitedepth MIN REQUIRED:[4.4.1] 26.18' averageoftwoadjacentsites PROPOSED: 0M
MIN REQUIRED:[4.5.1] 3.98' sitewidthinmetres+2=12.06% PROPOSED: 0M
MIN REQUIRED:[4.6.1] 35.10' 10.7mMIN PROPOSED: 0.00M
MAX ALLOWED:[4.16.1] 48.88' 40%buildingdepth PROPOSED:
ALLOWED:[4.7.1] 0.0sq.ft sitearea 0.60
ALLOWED:[4.7.1A] 2,822.2sq.ft sitearea 0.70 MAX ABOVEGRADE:[4.7.1A] 3,993.4sq.ft 371sq.m
707sq.ft
THERMALEXCL -14sq.ft SECONDSTOREY 1,190.2sq.ft
THERMALEXCL -23.8sq.ft 2%reduction
1,190.2sq.ft
THERMALEXCL -23.8sq.ft 2%reduction
0.0sq.ft COV PORCHOVERAGE 0.0sq.ft
-207.3sq.ft reduction(max10%ofFSR)
2,818.7sq.ft (0.70FSR)
MAX ALLOWED:[4.7.3.(d)] 28sq.ft whichis1%ofabovegradearea PROPOSED: 25sq.ft .9% OVERAGE: 0sq.ft
includingbalcony&deckarea MAX ALLOWED:[4.7.4.(g)] 367sq.ft whichis13%ofpermittedfloorarea PROPOSED: 35sq.ft .2% OVERAGE: 0sq.ft
MAX ALLOWED:[4.7.4.(i)] 282sq.ft whichis10%ofabovegradearea PROPOSED: 207.3sq.ft .3%
MAX ALLOWED:[4.8.1.(b)] 1,814.3sq.ft whichis45percentofsitearea PRINCIPLEDWELLINGFOOTPRINT 1,206.9sq.ft includingcoveredporches GARAGE 497.6sq.ft TOTAL 1,704.5sq.ft 42.3%
MAX ALLOWED:[4.8.4] 2,419.0sq.ft whichis60%ofsitearea SITECOVERAGE 1,704.5sq.ft ASPHALTAPRON 26.7sq.ft ORANGE CONCRETESTAIRS 109.6sq.ft YELLOW PATIOS&RET WALLS 224.4sq.ft GREEN WALKWAYS PAVERS 352.0sq.ft PURPLE PROPOSED: 2,417.2sq.ft 60.0%) FIRSTFLOOR SCALE:1/4"=1'-0" TOTALFLOORAREA ,190.23sq.ft THERMALEXCLUSION 23.80sq.ft COUNTEDFLOOR AREA ,166.42sq.ft FRONTUNITCOV PORCH 34.88sq.ft REARUNITCOV PORCH 34.88sq.ft BAYWINDOW .60sq.ft CEILINGHEIGHT 9.060 FRONTUNITAREA(GROSS) 521.36sq.ft REARUNITAREA(GROSS) 668.86sq.ft .00 36" .00 36" NONLOAD BEARINGWALLFOR FUTUREACCESS NONLOAD BEARINGWALLFOR 23.25 (F) G1 G2 23.38 (C) 239.5 238.3 241.8 242.8 242.8 242.0 241.1 240.7 241241.2 .8 240240.9 .7 241.4 241.4 242241.8242.2 .8 242.8 242.8 242.6 242.1 241.9 241.6 241.1 240.9 241.4 241241.4242.7242.1242.5 .6 242.0320ØDeci243.3440ØDeci 242.6 241.8 241.8 242.3 242.7 IC 242.7 243.0 243.5 243.0 237237.5 .8 238.5239239.2 .6 239.5 239.1 238.4 237.8 237.2 240237.9 .3 239.5 239.0 238.1 237.6 237.3 237237.3238.7239.6 .7 239.2 239.6 Multi-stem 280ØDeci 239.4 240.5 240.9 240.8 Multi-stem 380ØDeci 240.2Multi-stem 370Ø 239.3 239.3 240.3 240.0 240.2 240.2 240.5 240.5 241.0 241.0 239.9 239.5 241.6 241.7 241.7 IC 243.6 IC 243.6 242.3 242242.3 .3 WEST23RD AVENUE Curb GutterLine Sidewalk Hedge Hedge 16 PLAN4576 Dwelling#3523 C PLANBCP24700 Dwelling#3511 Deck Porch Porch Overhang Overhang TheBottomof Transformer's Elev is267.2 Deck 240.6 240.3 239.5 239.5 238.6 239.4 20'WIDELANE 241.6 241241.7 .7 240.1 240.1 239.6 Fire Place 242.6 242.7 242.7 241.8241.8 240.7 243.0 242.1 IRONIRONPOST POST POWER POLE IRONPOST IRONPOST LEAD PLUG LEAD PLUG INCEPTION CHAMBER CONSTRUCTION ACCESS PROPOSEDTWOCARGARAGE GARAGEFOOTPRINT497.55SQ.FT ROOFPEAK EL 253.07' .OTOPPLATE EL 248.46' .O.CWALL EL 240.40' SLABHIGH EL 239.60' SLABLOW EL 239.42' PROPOSEDFOOTPRINT1241.79SF (INCLUDINGCOVEREDPORCHES) PROPOSEDDUPLEXUNIT#2[603.36SF] 1/2STOREYW/CRAWLSPACE ROOFPEAK EL 274.54' THIRDFLOOR EL 262.13' SECONDFLOOR EL 252.90' MAINFLOOR EL 242.67' CRAWLSPACE EL 237.57' PROPOSEDDUPLEXUNIT#1[603.36SF] 1/2STOREYW/CRAWLSPACE ROOFPEAK EL 274.54' THIRDFLOOR EL 262.13' SECONDFLOOR EL 252.90' MAINFLOOR EL 242.67' CRAWLSPACE EL 237.57' FIREACCESSPATH UNIT 108.66' .12M FIREACCESSPATH UNIT FAP .21' 11.49M 14.50 [4.42m 150mm STORM CONNECTION PRESSURE 87 .3 PSI SERVICECONNECTIONNOTES: SANITARYPIPEMUSTBELEFTOFSTORMWHILELOOKINGFROM THESTREET PROTECTALLSANITARY&STORM(INCL DRAINS)FIXTURESWITH RIMELEVATIONSBELOW73.79 242.093'GEODETIC TRENCHINGFORUTILITYCONNECTIONSTOBECOORDINATED WITHENG DEPARTMENTTOENSURESAFEROOTZONESOF RETAINEDTREES METHODTOPROTECTSTREETTRESSTOBE APPROVEDBYPARKBOARD LOWESTFIXTURES: INSIDE MECH FLOORDRAINONCRAWLSPACELEVEL 237.57' TOILETONMAINFLOOR@244.17' OUTSIDE CONC PATIODRAIN@242.67' DRAINTILE@LOWESTCORNERGRADE1/2@239.10' UTILITY TRENCH SUMPS 16.47 [5.02m .62 [0.80m EXTERIORSTAIRINFO: 240.60' 242.67' .07'/24.84" RISE .21" ASPHALTAPRON WOOD FENCE CONC PATIO GUTTER GUTTER ASPHALTAPRON CONC PATIO FIN TOC242.67' 240.60' CENTERLINEOFPAVEDLANE 239.50' 239.60' 239.50' 238.35' 238.45' 238.60' B/OSTAIR LAWN LAWN 241.60' LAWN 241.60' 240.60' 240.60' B/O STAIRS 241.60' EXTERIORSTAIRINFO: GRADETOENTRYPORCH 241.60'TO 242.67' .07'/12.84" RISE 2R .42" B/OSTAIR 240.60' 239239.10' .10' WOOD FENCE WOOD FENCE WOOD FENCE 6' WOOD FENCE B/OSTEP EL241.60' UP 4R 4R REMOVE TREE#8 X TPZ#1 RETAIN TREE#1 RETAIN RETAIN TPZ#2 RETAIN TREE#2 .50 .90m .9mCRZ .00 .00 .60 .01m .6' .5'2mCRZ .9mCRZ .00 .00 .60 .01m 2mCRZ REMOVE TREE#3 TPZ#5 RETAIN TREE#5 .80 .38m .8' .4mCRZ NORTHNORTHPL PL SOUTHSOUTH 1 EX241.60' PR240.60' 4 EX242.60' PR241.60' EX240.10' PR240.60' EX241.80' PR241.60' EX240.00' PR239.40' EX239.40' PR239.40' 5 EX239.40' PR239.40' EX239.40' PR239.40' SG239.50' SG238.60' SG240.52' SG239.50' SG240.10' SG241.80' SG241.70' SG242.70' SGSG242.10' 243.00' DUPLEX RESIDENCE 3517 WEST 23RD AVENUE CONSTRUCTION: DESIGN: 216 289 ALEXANDER STREET VANCOUVER BC V6A 4H6 PHONE: (604) 677 7877 | ARCHITRIXSTUDIO .COM drawings design legal property Design and cannot be used or reproduced without written consent Contractors must verify all site conditions and confirm all dimensions Dimensions given scaled dimensions NOTES & VERSIONS: DRAWNBY: 3517W23RD STARTDATE: STRUCTURALENGINEERING: GEOTECHNICALENGINEERING: ARBORIST: CEACONSULTANT: 2022 .09 .21_PRELIM FOR STRUCTURAL & CEA JOB#: SS KN MARCH2022 VANCOUVER B .C 2882W35thAve Vancouver BCV6N2M4 Phone:(604)603-5820
Surrey BC V3W0N5 Phone:(604)599-8890 59FernwayDr,
BCV3H5K5 Phone:(604)362-7021
BUILDINGDIMENSIONNOTE: GRIDLINEDIMENSIONSARETOFACEOFSHEATHING FACEOFCONCRETE ADD .5"TOEACHSIDEFORFACEOFCLADDINGDIMENSION (C)FORDIMENSIONSTOCLADDING (F)FORDIMENSIONSTOFOUNDATION ROUGHOPENINGSNOTE: ALLTHEEXERIOROPENINGSDIMENSIONNOTESAREROUGHOPENINGS ALLTHEINTERIORDOORSAREOFFSET3"FROMSTUD .N.OONDRAWINGS SITEPLAN A1.0
FLOORAREA MAX ALLOWABLE: 516.7sq.ft 48.00sq.m.] [2.2.A.(d)&4.7.3.(c)(i)] FLOORAREA PROPOSED: 497.6sq.ft 46.22sq.m.] FLOORAREA EXCLUDED: 0.0sq.ft 0.00sq.m OVERAGE: 0.0sq.ft 0.00sq.m HEIGHT MAX ALLOWED: 3.7m 12.14feet tohighestpointofflatroof [2.2.A.(a)] tomeanlineofslopedroof & .6m 15.09feet totalheight HEIGHT PROPOSED: 13.3feet 4.06m WIDTH MAX ALLOWED: 19.65'[8.04m] 80%ofwidthofrearyard WIDTH PROPOSED: 23.38' 7.13m SITEPLAN SCALE: 1/8"=1'-0" SITEPLAN:SITESETBACKS&IMPERMEABLES SCALE: 1/8"=1'-0" AVERAGEGRADECALCULATIONSHEET: 518E18THAVENUE FINISHEDGRADE 1-2 154.30' + 154.25' 2 24.37' ,759.68' 2-3 154.25' + 154.20' 2 48.17' ,429.02' 3-4 154.20' + 154.20' 2 24.37' ,757.85' 4-1 154.20' + 154.30' 2 48.17' ,430.22' TOTAL 290.16' 44,753.55' AVERAGEFINISHGRADE 44,753.6 290.16' = 154.24' LIVINGSUITEMUSTBENOMORETHAN .5M(4.92')BELOWAFG= 149.32' ZONING10.21.1 PROPOSED0F= 155.70' FRONTDOORSMUSTBENOMORETHAN .8M(5.91')ABOVEGRADE= 161.01' RS-1ZONING4.17.1 PROPOSED1F= 155.70' BCONE-CALLPRIORTOANY EXCAVATION:1-800-474-6886 BCONETICKET#:20222714935 UNIT-AREACOUNT UNIT1(FRONTUNIT) MAINFLOOR 521.4sq.ft SECONDFLOOR 521.4sq.ft HALFFLOOR 370.8sq.ft THERMALEXCLUSION(2%) -28.3sq.ft LOWSLOPECEILING(EXCLUDED) -104.1sq.ft TOTALAREAUNIT 1,281.2sq.ft UNIT2(REARUNIT) MAINFLOOR 668.9sq.ft SECONDFLOOR 668.9sq.ft HALFFLOOR 369.1sq.ft THERMALEXCLUSION(2%) -34.1sq.ft LOWSLOPECEILING(EXCLUDED) -103.2sq.ft TOTALAREAUNIT 1,569.5sq.ft TYP PAVER CONCRETEPAVERS SANDSETTINGBED OF3/4"AGG BASEONFABRICFILTER PREPAREDSOILON DRAINROCK 2X6WOODCAP 2X4BOARDS 6X6POST 8X8X2POSTCAP CONCFOOTING ONDRAINROCK FENCE&RETAININGDETAIL SCALE:1/4"=1'-0" A TYPICALWOODFENCE B WOODFENCE ONRETAININGWALL PL SUBJECTLOT .00 .00 NONLOAD BEARINGWALLFOR FUTUREACCESS NONLOAD BEARINGWALLFOR 23.25 (F) G1 G2 23.38 (C) 32.98 122 .19 122 .21 32.99 PROPOSEDTWOCARGARAGE GARAGEFOOTPRINT497.55SQ.FT ROOFPEAK EL 253.07' .OTOPPLATE EL 248.46' .O.CWALL EL 240.40' SLABHIGH EL 239.60' SLABLOW EL 239.42' PROPOSEDFOOTPRINT1241.79SF (INCLUDINGCOVEREDPORCHES) PROPOSEDDUPLEXUNIT#2[603.36SF] 2 1/2STOREYW/CRAWLSPACE ROOFPEAK EL 274.54' THIRDFLOOR EL 262.13' SECONDFLOOR EL 252.90' MAINFLOOR EL 242.67' CRAWLSPACE EL 237.57' PROPOSEDDUPLEXUNIT#1[603.36SF] 2 1/2STOREYW/CRAWLSPACE ROOFPEAK EL 274.54' THIRDFLOOR EL 262.13' SECONDFLOOR EL 252.90' MAINFLOOR EL 242.67' CRAWLSPACE EL 237.57' (MIN .8M)[4 .5] (MIN .8M)[4 .5] .77 27.39 24.33 24.33 4848 .17 21 .40 23.25 2.84 2.83 LAWN CONC PATH STAIRS CONC PAD GRAVEL GRAVEL ASPHALTAPRON 5 .91 1 .00 COV PORCH COV PORCH 3 .00 5 .91 74 .45 3.00 .91 13.09 CONC PATIO CONC PATIO STAIRS 22.00 FIREPLACE O/H FIREPLACE O/H 20.00 .91 13.09 1.00 3.00 CONC PAVERS CONC PAVERS CONC PAVERS CONC PATH .00 CONC PATH 3.00 CONC PATH 6 .03 47 .48 (F) RY 48 .17 (F) BD 26 .56 (F) FY 55 .59 (F) RY 40 .08 (F) BD 26 .51 (F) FY 4.32(F) 24.33(F) .33(F) 4.20(C) 24.58(C) .20(C) 23.38(C) 23.25(F) 55 .46 (C) RY 40 .33 (C) BD 26 .39 (C) FY 4.33(F) 24.33(F) .33(F) 4.87(F) 23.25(F) 4.87(F) 4.81(C) 23.38(C) 4.80(C) 4.20(C) 24.58(C) 4.20(C) 47 .36 (C) RY 48 .42 (C) | BD 26 .44 (C) FY 2 .22 (F) 21 .40 (F) 2 .15 (C) 21 .53 (C) NORTHNORTHPL PL SOUTHSOUTHPL PL EX241.60' PR240.60' EX242.60' PR241.60' 2 EX240.10' PR240.60' 3 EX241.80' PR241.60' EX240.00' PR239.40' 7 EX239.40' PR239.40' EX239.40' PR239.40' 6 EX239.40' PR239.40' SG239.50' SG238.60' SG240.52' SG239.50' SG240.10' SG241.80' SG241.70' SG242.70' SGSG242.10' 243.00' Unit 320 507 W Broadway, Vancouver, BC V5Z 0B4 vancouver.ca ENGINEERINGDEPARTMENT Water,Sewer, GreenInfrastructure Sewer&DrainageDesignBranch July 20, 2022 To: Khang Nguyen DBA: Architrix Design Studio 289 Alexander Street # 216 Vancouver, BC V6A4H6 Location: 3517 W 23RD AVENUE, Vancouver, BC V6S 1K4 Legal Description: LOT 15 OF LOT BLOCK 26 DISTRICT LOT 139 PLAN 4576 Permit Number: SW 2022 00820 Permit Description: Residential Sewer & Water New Subject: Public Sewer and Water Servicing Information Dear Khang Nguyen DBA: Architrix Design Studio Thank you for submitting a “Pre Application for Engineering Services” for your development. The following provides important information for your site sewer and water servicing which must be included on your site plan 1. Plumbing ixtures re estricted s follows A) A sanitary fixtures (including floor drains) with rim elevations below 73.79 m (geodetic) or 242.093 ft (geodetic) must be protected. (see the “Fixture Restriction Guidelines Update attached) B) All storm fixtures with rim elevations below 73.79 m (geodetic) or 242.093 ft (geodetic) must be protected. (see the “Fixture Restriction Guidelines Update attached) 2. Diameters of sewer connections 100 Sanitary, 150 Storm A) Note: Sanitary pipe will be left of the storm pipe when looking at the property from the street/lane 3. Proposed sewer connection location is: 4.42m East of the West PL, to W 23RD AVENUE 4. Minimum depth (invert elevation) of sanitary/storm connections at property line is: 72.27m 237.11 5. Maximum depth (invert elevation of sanitary/storm connections at property line is: 71.74m 235.37 The Elevation shown on your plan must be between the Minimum and Maximum invert elevation stated above. 6. Diameter of water connection: 40mm 7. Proposed water connection location is: 5.02m East of the West PL, to W 23RD AVENUE 8. The estimated minimum water main pressure is: 87.3 (psi) Unit 320 507 W Broadway, Vancouver, BC V5Z 0B4 vancouver.ca 9. Your site plan must include the provided attached sheet labelled Public Sewer and Water Connection Information”. Your Site Plan must also show: Public water, storm and sanitary services with sizes and dimensions at the property line Invert(bottom of pipe) elevation of the storm and sanitary connections at the property line (one elevation for the storm and sanitary connects); Plumbing fixture restriction elevation as supplied by the City of Vancouver Water Pressures as supplied by the City of Vancouver include meter location details and domestic flow ates in U.S. gallons per m nute lot is greater than ½ acre Location of the existing gas service (contact BC ONE CALL for location AND the proposed location if you are installing new gas service. It is the responsibility of the owner to ensure that both the existing and/or proposed gas service does not conflict with the proposed sewer and water ervices Review of your site plan can be done electronically via our online system. To do so you will need to upload PDF document of your site plan to your account. Visit vancouver.ca/permits/apply to create your account. Attached for your information is a sample “Site Plan” showing the engineering information to be included. Please be advised that there are additional costs to install your sewer connection at a epth greater than the “minimum depth” stated in this letter. If you have any questions please contact the Sewers and Drainage Design Branch at 604 873 7357 Regards, Sewer Design Branch Engineering Services ENGINEERINGDEPARTMENT Water,Sewer,&GreenInfrastructure Sewer DrainageDesignBranch PUBLICSEWERANDWATERCONNECTIONINFORMATION SEWER INFORMATION This site plan shows the locations, sizes and invert elevations of the public storm and sanitary sewer connections. Plumbing Fixtures are restricted as follows: A) A sanitary fixtures (including floor drains) with rim elevations below 73.79 m (geodetic) or 242.093 ft (geodetic) must be protected (see Fixture Restriction Guidelines Update attached). B) A storm fixtures with rim elevations below 73.79 m (geodetic) or 242.093 ft (geodetic must be protected (see Fixture Restriction Guidelines Update attached). Water Information This site plan shows the location and size of the public water connection. The estimated minimum water main pressure is 87.3 (psi) NOTES The City of Vancouver does not guarantee the accuracy of the information provided on this Plan and circumstances may prevent the City from installing the public sewer and/or water connections at the locations and depths shown on this Plan. The Owner is responsible for locating and connecting to the public sewer and water connections installed by the City regardless of their actual installed locations and depths. The Owner is responsible for ensuring that the sizing of the private plumbing system adequate for the storm & sanitary sewer discharges and the domestic & fire water flows. No person shall connect building sewer or water system to a public connection without first obtaining “Public Sewer & Water Connection Permit”. All revisions related to the sewer and water information on this site plan must have Engineering review and acceptance prior to making the change(s). Any requests for changes after a City crew has arrived at the site may cause installation delays and additional costs. SITEPLANNOTES: 1 3'CLEARFIREFIGHTINGACCESSTOBEMAINTAINEDATALLTIMES NOPROJECTIONS INCLUDINGSERVICE/UTILITYCONNECTIONSPERMITEDINDESIGNATED3'PATH 2 ELECTRICVEHICLEOUTLETBOXTOBEINSTALLEDINTHEPARKINGAREA 3 ROOFSOFFITSLOCATEDWITHIN .2mOF PROPERTYLINESHALLHAVENOOPENINGSAND COMPLYWITHVBBL2019 .10.15.5(11) 4 ENTIREBUILDINGTOBESPRINKLEREDTO:2XNFPA13-D

GBSENGINEERINGGROUPLTD #14329HawkstreamDr Surrey BC V3W0N5

59FernwayDr, PortMoody BCV3H5K5 Phone:(604)362-7021

MYCORRHIZAURBANFORESTRY 1617783Ave Surrey BCV4N5T3 Phone:(778)222-6767

DOMUSHOMEENERGYINC 1556E5thAve#101 Vancouver BCV5N1L7 Phone:604-243-8616

UP 9R UP 9R 237.57' UNIT BASMENTFLOOR POLISHEDCONCRETE MECH ROOM [1.20MHT UNCONDITIONEDCRAWLSPACE] 2X8MECH CHASE 2X8MECH CHASE 237.57' UNIT BASMENTFLOOR CO/SA 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR POLISHEDCONCRETE MECH ROOM [1.20MHT UNCONDITIONEDCRAWLSPACE] CO/SA NOTE: [SPRINKLEREDTONFPA13D] NOTE: [SPRINKLEREDTONFPA13D] E/R E/R SPKL'S SPKL'S FD 48 .42 (C) 48 .17 (F) 20 .19 6 .90 6 .90 14 .19 3 5 2 1 4 AA B A12.17' 12.17' 24.33 (F) A 24.58 (C) B CCA6 D A7 DUPLEX RESIDENCE 3517 WEST 23RD AVENUE CONSTRUCTION: DESIGN: 216 289 ALEXANDER STREET VANCOUVER BC V6A 4H6 PHONE: (604) 677 7877 | ARCHITRIXSTUDIO .COM drawings design legal property Design and cannot be used or reproduced without written consent Contractors must verify all site conditions and confirm all dimensions Dimensions given scaled dimensions NOTES & VERSIONS: DRAWNBY: 3517W23RD STARTDATE: STRUCTURALENGINEERING: GEOTECHNICALENGINEERING: ARBORIST: CEACONSULTANT: 2022 .09 .21_PRELIM FOR STRUCTURAL & CEA JOB SS KN MARCH2022 VANCOUVER B .C 2882W35thAve Vancouver BCV6N2M4 Phone:(604)603-5820
Phone:(604)599-8890
BUILDINGDIMENSIONNOTE: GRIDLINEDIMENSIONSARETOFACEOFSHEATHING FACEOFCONCRETE ADD .5"TOEACHSIDEFORFACEOFCLADDINGDIMENSION (C)FORDIMENSIONSTOCLADDING (F)FORDIMENSIONSTOFOUNDATION ROUGHOPENINGSNOTE: ALLTHEEXERIOROPENINGSDIMENSIONNOTESAREROUGHOPENINGS ALLTHEINTERIORDOORSAREOFFSET3"FROMSTUD .N.OONDRAWINGS FLOOR PLANS A2.0 FIRSTFLOOR SCALE:1/4"=1'-0" TOTALFLOORAREA 1,190.23sq.ft THERMALEXCLUSION 23.80sq.ft COUNTEDFLOORAREA 1,166.42sq.ft FRONTUNITCOVPORCH 34.88sq.ft REARUNITCOV PORCH 34.88sq.ft BAYWINDOW 7.60sq.ft CEILINGHEIGHT .060 FRONTUNITAREA(GROSS) 521.36sq.ft REARUNITAREA(GROSS) 668.86sq.ft CRAWLSPACE SCALE:1/4"=1'-0" CRAWLSPACE ,190.23sq.ft COUNTEDFLOORAREA .00sq.ft CEILINGHEIGHT 3.937 SECONDFLOOR SCALE:1/4"=1'-0" TOTALFLOORAREA 1,190.23sq.ft THERMALEXCLUSION 23.80sq.ft COUNTEDFLOORAREA 1,166.42sq.ft CEILINGHEIGHT FRONTUNITAREA(GROSS) 521.37sq.ft REARUNITAREA(GROSS) 668.86sq.ft Q MIRROR BATH TILE BATHTUB 5 DN 16R UP 15R 36"H 36"H DN 16R UP 15R 36"H 36"H 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 252.90' UNIT 2NDFLOOR ROOFABOVE DEN HARDWOODFLOORING TYP THISFLOORUNO 252.90' UNIT 2NDFLOOR 210 DRESSER ROOFABOVE CO/SA BEDROOMBEDROOM SASA SA E/R E/R E/R CLOSET 2X8MECH CHASE WIC CUPBOARDS ABOVE CO/SA E/R LAUNDRY BEDROOMBEDROOM SASA LAUNDRY TILE CLOSET WIC CLOSET ROOF ABOVE BATH TUB x2 BATH TILE SHOWER 10 ROOF ABOVE ROOF ABOVE METALFLASHING UNDERNEATHCLADDING SLOPEDAWAYTOPARAPET REFERDETAILSD4&A3.0 SLOPED FLASHING METALFLASHING UNDERNEATHCLADDING SLOPEDAWAYTOPARAPET REFERDETAILSD4&A3.0 SLOPED FLASHING WATER WATER HRVUNIT ABOVE WATERCURTAIN WATERCURTAIN 5 2 6 5 6 0 2 5 0 2 2 5 2 2 S/GWATERCURTAIN 2 5 S/GWATERCURTAIN 5 4 S/G WATER CURTAIN SILL- .11' FROM1ST FL ABOVE *WIN SILL FROM HIGHEST LANDING 4 S/G WATER CURTAIN SILL- .11' FROM1ST FL ABOVE *WIN SILL FROM HIGHEST LANDING T/OPARAPET-166.77' FD FLATROOFCANOPY GRAVELBALLAST TOJ165.75' T/OPARAPET-166.77' FLATROOFCANOPY GRAVELBALLAST TOJ165.75' SLOPED FLASHING 2 5 S/GWATERCURTAIN 5 2 HEATPUMP A/C 2 10 6 2 10 6 210210 106 HEATPUMP A/C CLOSET 48 .42 (C) 48 .17 (F) 20 .19 6 .90 6 .90 14 .19 3 5 2 1 4 AA B A12.17' 12.17' 24.33 (F) A 24.58 (C) B CCA6 D A7 A/C UNIT 2 .00 2 .00 A/C UNIT 2.00 2.00 UP 16R UP 16R CO/SA UNIT2 MAINFLOOR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR MIRROR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 242.67' CO/SA EDU EDU 2 2 LIVING POWDER TILE 106 DINING 106 36" .R 36"H 2X8MECH CHASE 2X8MECH CHASE STORAGE 36" .R 36"H POWDER TILE STORAGE LIVING ENTRY CLOSET KITCHEN HARDWOODFLOORING TYP THISFLOORUNO CLEAR 6X CLEAR DN 9R UNIT1 MAINFLOOR 242.67' KITCHEN HARDWOODFLOORING TYP THISFLOORUNO ELEC .P E/R E/R SHEARWALL REFERSTRUC FR 36"COOKTOP ELEC .P E/R E/R ENTRY CLOSET KITCHEN ISLAND DINING DINING DN 9R ROOF O/H ROOFO/H ROOF O/H ROOFO/H 3 .00 36" 3.00 36" DRAIN FUTURE LOW [VBBL 3 .8 .5 .5 .(1)(C) FUTURE SHOWER ROUGHIN 3 .00 36" 3.00 36" DRAIN FUTURE LOW [VBBL 3 .8 .5 .5 FUTURE.(1)(C) SHOWER ROUGHIN PRE-FAB GRATEDRAIN PRE-FAB GRATEDRAIN INTERIOR STAIR CAL'S: M .F TO S .F 242 .67' TO 252 .90' = 10 .23' RISE= 16R @ 7 .68" RUN=10 .04" INTERIOR STAIR CAL'S: M .F TO S .F 242 .67' TO 252 .90' = 10 .23' RISE= 16R @ 7 .68" RUN=10 .04" TREAD=11" F/P OVERHANG T/O JOIST 156 .69' F/P OVERHANG T/O JOIST 156 .69' NONLOAD BEARINGWALLFOR FUTUREACCESS NONLOAD BEARINGWALLFOR FUTUREACCESS 18 S/G 12 S/G SLIDER 6 6FROSTED 4 6FROSTED 3 3 S/GWATERCURTAIN 2 3 6S/GWATERCURTAIN 18 S/G 12 S/G SLIDER BAYWIN BAY WIN OVERHANG T/O JOIST 156 .69' KITCHEN ISLAND * GB G1 G1 G2 EXTERIORSTAIRINFO: GRADETOENTRYPORCH 240.60'TO242.67' .07'/24.84" RISE=4R@ .21" RUN 12" 6' WOOD FENCE 6' WOOD FENCE CONC PATIO FIN TOC242.67' 6' WOOD FENCE 6' WOOD FENCE CONC PATIO FIN TOC242.67' PAVERS 240.60' B/OSTAIR EL240.60' 241 .60' 241.60' LAWN 241.60' 240.60' B/O STAIRS 241 .60' 242 .60' PAVERS 241.60' 243 .00' EXTERIORSTAIRINFO: GRADETOENTRYPORCH 241.60'TO242.67' 1.07'/12.84" RISE 2R@ .42" RUN=12" 240 .60' 240 .60' 241 .60' B/OSTAIR EL240.60' 4' WOOD FENCE 6' WOOD FENCE 4' WOOD FENCE 6' WOOD FENCE ENTRY PORCH (MIN 1 .8MX1 .8M)[4 .17 .5] ENTRY PORCH (MIN 1 .8MX1 .8M)[4 .17 .5] B/OSTEP EL241.60' UP 2R UP4R UP 4R 48 .42 (C) 48 .17 (F) 20 .19 6 .90 6 .90 14 .19 3 5 2 1 4 AA12.17' 12.17' 24.33 (F) A 24.58 (C) B CCA6 D A7 FLOORPLANNOTES: 1 ASPERVBBL20149.10.19.3.(1)SMOKEALARMSSHALLBEINSTALLEDSOTHAT: A.)WITHINDWELLINGUNITS;SUFFICIENTSMOKEALARMINSTALLEDONEACHSYOREYINCLUDINGBASEMENTS AND B.)ONANYSTOREYOFADWELLINGUNITCONTAININGSLEEPINGROOMSASMOKEALARMISINSTALLED i)INEACHSLEEPINGROOM AND ii)INALOCATIONBETWEENTHESLEEPINGROOMSANDTHEREMAINDEROFTHESTOREY ANDIFTHESLEEPING ROOMSARESERVED BYHALLWAY THESMOKEALARMSSHALLBELOCATEDINTHEHALLWAY 2ASMOKEALARMREQUIREDBYSENTENCE(1)SHALLBEINSTALLEDINCONFORMANCEWITHCAN/ULC-S553 "INSTALLATIONOFSMOKEALARMS" 3 SMOKEALARMSREQUIREDINARTICLE9.10.19.1 ANDSENTENCE(1)SHALLBEINSTALLEDONORNEARTHECEILING 4 CARBONMONOXIDEALARMSSHALLBEREQUIREDASPER9.32.4.2 5 ASPER2019VBBL&BUILDINGBY-LAW3.8.5.3&9.5.5.1 A.)INTERIORDOORSARETOBEMINIMUM2'-10"ORACLEAROPENINGOD2'-8" B.)EXTERIORDOORSARETOBEMINIMUM3'-0"

GBSENGINEERINGGROUPLTD #14329HawkstreamDr Surrey BC V3W0N5 Phone:(604)599-8890

59FernwayDr, PortMoody BCV3H5K5 Phone:(604)362-7021

MYCORRHIZAURBANFORESTRY 1617783Ave Surrey BCV4N5T3 Phone:(778)222-6767

DOMUSHOMEENERGYINC 1556E5thAve#101 Vancouver BCV5N1L7 Phone:604-243-8616

SelectVBBLEnergyCompliancePath (dropdown, see VBBL tab) LargeHomes(>325m2) Energymodellingsoftware version: TotalsiteGHG's (from calculator tab) Window-to-wallratio 30%? Energymodellingstandard Rezoning Project(area-weightedaverage) Total (m2) Required(area-weightedaverage) Project(area-weightedaverage) Total (m2) Required(area-weightedaverage) 20.0 Complete 58.0 Complete EmissionsFactors Electricity Gas (kgCO2e/GJ) 51 51 51 51 51 Project GHGI (kgCO2e/m2/yr) 1.1 0.0 4.GHGI Performance Path Only Required GHGI (kgCO2e/m2/yr) (kWh/m2/yr)(kWh/m2/yr) 5020 20 20 20 20 20 90 90 0.0 0.0 0.0 1.1 3.0 Complete 100131Unit 518East17thAve Modelled FloorArea (m2) Unit 518East17thAve131 131 2.EnergyPathway Modelling Option#2:PerformancePath 3.MEUI&TEDI Performance Path Only Address(es) Unit Modelled FloorArea PROJECT MEUI TEDI REQUIRED MEUI TEDI 58 90 90 Address(es) Unit 131 Modelled ElectricityUse (GJ/a) Modelled GasUse (GJ/a) 50.03 Version 2.5PRE-PERMITENERGYCHECKLIST for1&2Familyand1-3StoreyResidentialBuildings This form to confirm the Vancouver Building Byla energy requirements for new 1-3 storey residentia buildings with permit applications after Jan 1st 2022. This form is be completed, signed and submitted for Building Permit qualified energy modeller. One form can represent multip units with matching specifications. Unit&Modeltype (dropdown) ProjectSummary 1&2Family Address(es) Unit Modelled FloorArea(m2) Unit 518East17thAve131 7931P00843 PFile# page ProjectcompletedRezoning 0.4 %floorarea mechcooled VBBLPart (codeminimum) PassiveHouseStandard CHBANetZero ILFIZeroEnergy Other(addtonotes) Thehighest-emittingheatingsystem modelled theprimarysystem Unit#1518E18thAvenue DUPLEX RESIDENCE 3517 WEST 23RD AVENUE CONSTRUCTION: DESIGN: 216 289 ALEXANDER STREET VANCOUVER BC V6A 4H6 PHONE: (604) 677 7877 | ARCHITRIXSTUDIO .COM drawings design legal property Design and cannot be used or reproduced without written consent Contractors must verify all site conditions and confirm all dimensions Dimensions given scaled dimensions NOTES & VERSIONS: DRAWNBY: 3517W23RD STARTDATE: STRUCTURALENGINEERING: GEOTECHNICALENGINEERING: ARBORIST: CEACONSULTANT: 2022 .09 .21_PRELIM FOR STRUCTURAL & CEA JOB#: SS KN MARCH2022 VANCOUVER B .C 2882W35thAve Vancouver BCV6N2M4 Phone:(604)603-5820
BUILDINGDIMENSIONNOTE: GRIDLINEDIMENSIONSARETOFACEOFSHEATHING FACEOFCONCRETE ADD .5"TOEACHSIDEFORFACEOFCLADDINGDIMENSION (C)FORDIMENSIONSTOCLADDING (F)FORDIMENSIONSTOFOUNDATION ROUGHOPENINGSNOTE: ALLTHEEXERIOROPENINGSDIMENSIONNOTESAREROUGHOPENINGS ALLTHEINTERIORDOORSAREOFFSET3"FROMSTUD .N.OONDRAWINGS FLOOR PLANS A2.1 ROOFPLAN SCALE THIRD1/4"=1'-0" FLOOR SCALE 1/4"=1'-0" GROSSFLOORAREA 707.3sq.ft THERMALEXCLUSION 14.1sq.ft AREABETWEEN1.2M-2.3MEXCLUSION 207.3sq.ft COUNTEDFLOOR 485.9sq.ft COVEREDPORCH DECK 88.6sq.ft CEILINGHEIGHT SLOPEDCEILING UNIT1AREA 370.8sq.ft UNIT2AREA 369.1sq.ft 5" GUTTER SOLID SOFFIT ASPHALTSHINGLE SLOPE12:4 PROJECTIONOFWALLBELOW PROJECTIONOFWALLBELOW SOLIDSOFFIT SOLIDSOFFIT .00 O/H 1 .00 O/H 1 .00 O/H .00 O/H ROOFVENTS 1:300 R/D ROOF187.56' PEAK 5" GUTTER ASPHALTSHINGLE PROJECTION OF WALL BELOW R/DR/D SOFFITVENTATGABLEENDS 5" GUTTER NON VENTED SOFFIT CONT RIDGE VENT CONT RIDGE VENT SLOPE10.9:12 ROOFVENTS 1:300 ROOFVENTS 1:300 PROJECTION OF WALL BELOW ASPHALTSHINGLE SLOPE10.9:12 PROJECTION OF WALL BELOW NON VENTED SOFFIT CONT RIDGE VENT PROJECTION OF WALL BELOW SOLID SOFFIT ASPHALTSHINGLE SLOPE12:4 PROJECTIONOFWALLBELOW NON VENTED SOFFIT NON VENTED SOFFIT SOFFITVENTATGABLEENDS R/D R/DR/D SOFFITVENTATGABLEENDS ROOFVENTS 1:300 ROOFVENTS 1:300 SOFFITVENTATGABLEENDS PROJECTIONOFWALLBELOW SOLIDSOFFIT SOLIDSOFFIT 0 SKYLIGHT 0 SKYLIGHT 0 SKYLIGHT 0 SKYLIGHT .50 O/H 1.50 O/H 1 .50 1O/H .50 O/H .50 O/H 1.50 O/H 1 .50 1O/H .50 O/H .00 O/H 1 .00 O/H 1 .00 O/H .00 O/H ROOFVENTS 1:300 0 SKYLIGHT 0 SKYLIGHT 0 SKYLIGHT 0 SKYLIGHT ASPHALTSHINGLE SLOPE10.9:12 ASPHALTSHINGLE SLOPE10.9:12 48 .42 (C) 48 .17 (F) 20 .19 6 .90 6 .90 14 .19 3 5 2 1 4 AA B A12.17' 12.17' 24.33 (F) A 24.58 (C) B CCA6 D A7 42"G.R 42"G.R Q DORMER ABOVE ROOFABOVE DN 15R DN 15R 36"H 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 262.13' UNIT2 3RDFLOOR 36"H 262.13' UNIT1 3RDFLOOR SA MASTERBED HARDWOODFLOORING TYP THISFLOORUNO SHOWER 6 x3 4 SKYLIGHT ABOVE 2 10 6 4 SKYLIGHT ABOVE MIRROR DORMERABOVE DORMER ABOVE DORMERABOVE ROOFABOVE 2 10 6 8 2 10 6 ENSUITE TILE 2 SKYLIGHT ABOVE 2 10 6 SHOWER 6 x3 MIRROR ENSUITE TILE 2 SKYLIGHT ABOVE DORMERABOVE DORMERABOVE INTERIOR STAIR CAL'S: S .F TO T .F 252 .90' TO 262 .13' = 9 .23' RISE= 15R @ 7 .44" RUN=10 .04" TREAD=11" INTERIOR STAIR CAL'S: S .F TO T .F 252 .90' TO 262 .13' = 9 .23' RISE= 15R @ 7 .44" RUN=10 .04" TREAD=11" 2 .3M (7 .54') SPRING 1 .2M (3 .94') SPRING LOW CEILING SPACE SLOPING ROOF LOWABOVE CEILING SPACE SLOPING ROOF ABOVE LOW CEILING SPACE SLOPING ROOF LOWABOVE CEILING SPACE SLOPING ROOF ABOVE COV PORCH WOODDECKING TODEL 262.71' TOJ EL 261.95' 6 S/G SLIDER 2 3 FLUSH HDR LOADBEARING WALLSUPPORTING TRUSS 4 S/G SILL- .23' FROM1ST FL BELOW *WIN SILL 3.7'FROM HIGHEST LANDING 4 S/G SILL- .23' FROM1ST FL BELOW *WIN SILL 3.7'FROM HIGHEST LANDING 6 S/G SLIDER 2 3 0 FLUSH HDR CLOSET WALL VENTS 1 .2M (3 .94') SPRING 2 .3M (7 .54') SPRING 1 .2M (3 .94') SPRING 1 .2M (3 .94') SPRING CLOSET LOW CEILING STORAGE LOW CEILING 4STORAGE0 6 BI-FOLD 4 0 6 BI-FOLD LOADBEARING WALLSUPPORTING TRUSS 2 SKYLIGHT ABOVE 2 SKYLIGHT ABOVE 2 SKYLIGHT ABOVE 2 SKYLIGHT ABOVE LOADBEARING WALLSUPPORTING TRUSS LOADBEARING WALLSUPPORTING TRUSS SA MASTERBED HARDWOODFLOORING TYP THISFLOORUNO 2 .3M (7 .54') SPRING 2 .3M (7 .54') SPRING 48 .42 (C) 48 .17 (F) 20 .19 6 .90 6 .90 14 .19 3 5 2 1 4 AA B A12.17' 12.17' 24.33 (F) A 24.58 (C) B CCA6 D A7 UNIT#1CEADOCUMENT AstheEnergyAdvisor(orqualifiedenergymodeller)assignedtothisproject,bysigning certifythat: Thischecklistwascompletedbasedoninformationprovidedbythebuilderandthemostrecentprepareddrawings (forEnerguide-basedprojects)theP-filewillbesubmitted yourServiceOrganizationforsubmission NRCan Buildercompany contact Builder#: Date: Visit www.vancouver.ca/homeenergy page of RSI2.64 ProposedSpecification assembly,system,fueltype,etc.) R/USIor Efficiency 5.AdditionalNotes WindowsandslidingglassdoorsUSI1.4 lower Yes Continuousairbarrier 2.5ACH50(orpermittedalternative) EAVerified (dropdown) 2.2Windows,curtainwallsandglazeddoors 2.3Skylightsandroofhatches Asidefromfrontentrydoor,USI1.84 lower USI1.44orlower HRV 75%SRE deg (oncontinuousmode better).65%for LanewayHomes Electricorgas.Gassystems:minimum92%AFUE,nosideventing. Indicatebackup secondarysystems EnergyFactor(UEForEF) 0.78 orthermalefficiency(TE) 90% PipingwrappedwithpipeinsulationR2(RSI0.35) Directventelectronicignitionandtimer(outdoor:electricormatch). Indicatetotalnumber fireplaces 3.3Fireplaces MinimumR48effective(RSI8.5) 1.4Flat,vaultedandcathedralroofs 1.5Underfoundationslab 1.6Exposedfloors R30eff.(RSI5.28);1&2Family LWH:R24eff.(RSI4.3) MinimumR14eff.(RSI2.5) 4.BuildingCharacteristicsSummary (completed by all projects) Concrete,2.5"XPS,2x4@24"OCR-14batt RSI4.36Yes N/A Deck 117/8"TJI@16"OCR-40batt CanopyRoof 117/8"TJI@16"OCR-40batt Mainroof Eng'd2xtruss@24"OCR-40batt RSI6.54Yes Insulation and Air Barrier 2x8@24"OCR-28batt FloorheadersR-28batt RSI4.14Yes Fenestration Mainentryexempt.Nootherside-hingeddoors. N/A MinimumR24eff.(RSI4.2) ThermalbreakmeetsR2.4eff.(RSI0.42) USI1.4Yes SkylightsUSI2.4orlower USI2.4 Yes N/A N/A Interior polyethylene 2.5ACH@50Pa Ground orienteddwellings 3"XPSunderslabandatslabedge EnergyRequirement 1.1Exteriorabove-gradewalls&floorheaders MinimumR22eff.(RSI3.85) 1.2Below-gradewalls MinimumR22eff.(RSI3.85) 1.3Flatattic Mechanical HRV 75%SREYes Electric Air-source-heatpump Heating Cooling 7.1HSPF/14.5 SEER Yes SkylightsUSI2.4orlower.RoofhatchesUSI2.9 lower 2.1Side-hingeddoors Yes Electrictank 0.83EFYes 3.1Ventilation 3.2Heatingsystems 3.4Domestichotwater Phone: BusinessLicense Signature BarbaraMeihuizen,7931 barbara@domushomeenergy.com 604-243-8616 BuilderSignature: EAnameandEA Emailaddress: 6.ContactInformation Authorization N/ARecirculatingsystem NGfireplace,directvent,electronicignition 64%EF 1.7Balconies,eyebrows,andexposedslabedge 1.8Airbarrier Yes WLKHomes WarrenKimmel C8951 26July2022 SelectVBBLEnergyCompliancePath (dropdown, see VBBL tab) LargeHomes(>325m2) Energymodellingsoftware version: TotalsiteGHG's (from calculator tab) Window-to-wallratio 30%? Energymodellingstandard Rezoning Project(area-weightedaverage) Total (m2) Required(area-weightedaverage) Project(area-weightedaverage) Total (m2) Required(area-weightedaverage) 13.0 20.0 Complete 52.0 58.0 Complete EmissionsFactors Electricity Gas (kgCO2e/GJ) 51 51 51 Project GHGI (kgCO2e/m2/yr) 1.1 0.0 4.GHGI Performance Path Only Required GHGI (kgCO2e/m2/yr) (kWh/m2/yr)(kWh/m2/yr) 5220 20 20 20 20 13 90 90 0.0 0.0 0.0 1.1 3.0 Complete 100131Unit 518East17thAve Modelled FloorArea (m2) Unit 518East17thAve131 2.EnergyPathway Modelling Option#2:PerformancePath 3.MEUI&TEDI Performance Path Only Address(es) Unit Modelled FloorArea PROJECT MEUI TEDI REQUIRED MEUI TEDI 58 90 90 Address(es) Unit 131 Modelled ElectricityUse (GJ/a) Modelled (GJ/a) 50.01 Jan-22 PRE-PERMITENERGYCHECKLIST for1&2Familyand1-3StoreyResidentialBuildings This form to confirm the Vancouver Building Byla energy requirements for new 1-3 storey residentia buildings with permit applications after Jan 1st 2022. This form is be completed, signed and submitted for Building Permit qualified energy modeller. One form can represent multip units with matching specifications. Unit&Modeltype (dropdown) ProjectSummary 1&2Family Address(es) Unit Modelled FloorArea(m2) Unit 518East17thAve131 7931P00844 PFile# page ProjectcompletedRezoning 0.4 %floorarea mechcooled VBBLPart (codeminimum) PassiveHouseStandard CHBANetZero ILFIZeroEnergy Other(addtonotes) Thehighest-emittingheatingsystem modelled theprimarysystem Unit#2518E18thAvenue AstheEnergyAdvisor(orqualifiedenergymodeller)assignedtothisproject,bysigning certifythat: Thischecklistwascompletedbasedoninformationprovidedbythebuilderandthemostrecentprepareddrawings (forEnerguide-basedprojects)theP-filewillbesubmitted yourServiceOrganizationforsubmission NRCan Buildercompany contact Date: Visit www.vancouver.ca/homeenergy page of RSI2.64 ProposedSpecification assembly,system,fueltype,etc.) R/USIor Efficiency 1.4 lat,vaultedandcathedralroofs 1.5Underfoundationslab 1.6Exposedfloors R30eff.(RSI5.28);1&2Family LWH:R24eff.(RSI4.3) MinimumR14eff.(RSI2.5) 5.AdditionalNotes WindowsandslidingglassdoorsUSI1.4 lower Yes Continuousairbarrier 2.5ACH50(orpermittedalternative) EAVerified (dropdown) 2.2Windows,curtainwallsandglazeddoors 2.3Skylightsandroofhatches Asidefromfrontentrydoor,USI1.84 lower HRV 75%SRE deg (oncontinuousmode better).65%for LanewayHomes Electricorgas.Gassystems:minimum92%AFUE,nosideventing. Indicatebackup secondarysystems EnergyFactor(UEForEF) 0.78 orthermalefficiency(TE) 90% PipingwrappedwithpipeinsulationR2(RSI0.35) Directventelectronicignitionandtimer(outdoor:electricormatch). Indicatetotalnumber fireplaces 3.3Fireplaces MinimumR48effective(RSI8.5) 4.BuildingCharacteristicsSummary (completed by all projects) Concrete,2.5"XPS,2x4@24"OCR-14batt RSI4.36Yes N/A Deck 117/8"TJI@16"OCR-40batt CanopyRoof 117/8"TJI@16"OCR-40batt Mainroof Eng'd2xtruss@24"OCR-40batt RSI6.54Yes Insulation and Air Barrier 2x8@24"OCR-28batt FloorheadersR-28batt RSI4.14Yes Fenestration Mainentryexempt.Nootherside-hingeddoors. MinimumR24eff.(RSI4.2) ThermalbreakmeetsR2.4eff.(RSI0.42) USI1.4Yes SkylightsUSI2.4orlower USI2.4 Yes N/A N/A Interior polyethylene 2.5ACH@50Pa Ground orienteddwellings 3"XPSunderslabandatslabedge EnergyRequirement 1.1Exteriorabove-gradewalls&floorheaders MinimumR22eff.(RSI3.85) 1.2Below-gradewalls MinimumR22eff.(RSI3.85) 1.3Flatattic Mechanical 75%SREYes Electric Air-source-heatpump Heating Cooling 7.1HSPF/14.5 SEER Yes SkylightsUSI2.4orlower.RoofhatchesUSI2.9 lower 2.1Side-hingeddoors Yes Electrictank 0.83EFYes 3.1Ventilation 3.2Heatingsystems 3.4Domestichotwater Phone: BusinessLicense Signature BarbaraMeihuizen,7931 barbara@domushomeenergy.com 604-243-8616 BuilderSignature: EAnameandEA Emailaddress: 6.ContactInformation Authorization N/ARecirculatingsystem NGfireplace,directvent,electronicignition 64%EF 1.7Balconies,eyebrows,andexposedslabedge 1.8Airbarrier Yes WLKHomes WarrenKimmel C8951 26July2022 UNIT#2CEADOCUMENT

EXTERIORWALL

2882W35thAve

Phone:(604)603-5820

GBSENGINEERINGGROUPLTD #14329HawkstreamDr Surrey BC V3W0N5 Phone:(604)599-8890

59FernwayDr, PortMoody BCV3H5K5 Phone:(604)362-7021

MYCORRHIZAURBANFORESTRY 1617783Ave Surrey BCV4N5T3 Phone:(778)222-6767

DOMUSHOMEENERGYINC 1556E5thAve#101 Vancouver BCV5N1L7 Phone:604-243-8616

FRREXTERIORWALL-[EFF R-22INSULATED]

A-9.10.3.1.AASSEMBLYW2(1HRFRR)

DUPLEX RESIDENCE 3517 WEST 23RD AVENUE CONSTRUCTION: DESIGN: 216 289 ALEXANDER STREET VANCOUVER BC V6A 4H6 PHONE: (604) 677 7877 | ARCHITRIXSTUDIO .COM drawings design legal property Design and cannot be used or reproduced without written consent Contractors must verify all site conditions and confirm all dimensions Dimensions given scaled dimensions NOTES & VERSIONS: DRAWNBY: 3517W23RD STARTDATE: STRUCTURALENGINEERING: GEOTECHNICALENGINEERING: ARBORIST: CEACONSULTANT: 2022 .09 .21_PRELIM FOR STRUCTURAL & CEA JOB#: SS KN MARCH2022 VANCOUVER B .C
Vancouver BCV6N2M4
BUILDINGDIMENSIONNOTE: GRIDLINEDIMENSIONSARETOFACEOFSHEATHING FACEOFCONCRETE ADD .5"TOEACHSIDEFORFACEOFCLADDINGDIMENSION (C)FORDIMENSIONSTOCLADDING (F)FORDIMENSIONSTOFOUNDATION ROUGHOPENINGSNOTE: ALLTHEEXERIOROPENINGSDIMENSIONNOTESAREROUGHOPENINGS ALLTHEINTERIORDOORSAREOFFSET3"FROMSTUD .N.OONDRAWINGS SECTIONS A3.0 7 .86 SILL 3 .70 CLEAR LANDING DIST 2 .11 SILL 3 .00 CLEAR LANDING DIST 154.20' 154.20' 10 .94 BATH HALLDEN HALLPOWDER STORAGE CRAWLSPACE 7 .86 DORMER SPRING POINT 6 .83 [2 .08m HEIGHT CLEARANCE SECTIONAA' SCALE:1/4"=1'-0 .50 O/H .00 .00O/H O/H 12 4 6 .83 [2 .08m HEIGHT CLEARANCE 12 10.9 7 .15 STAIR SIDE DORMER SPRING POINT 6 .83 [2 .08m HEIGHT CLEARANCE LINEMAINROOF BEYOND 4 .61 SILL HT 3 .50 RAILING HT TYP HALL .69 SILL 3 .00 LANDING DIST D3 04 D3 02 D3 05 D3 03 R1 W1 F1 F2 W2 W4 F2 R1 W2 F2 10.7MHEIGHTLINE SG@PL 240.10' SG@PL 241.70' MAXHT 10.7M 240.10'+35.10' MAXHT 10.7M 241.70' 35.10' .937 [1.20m SOLIDSOFFIT REQ'DVBBL 9.10.15.5.(11) 3/4HRFRR RATINGREQ'D VBBL .10.15.5.(3) 3.937 [1.20m SOLIDSOFFIT REQ'DVBBL .10.15.5.(11) +3/4HRFRR RATINGREQ'D VBBL9.10.15.5.(3) MAINFLOOR (T.O CONC TOPP'G) EL 242.67' ROOFPEAK (T.O SHEATHING) EL 274.54' SECONDFLOOR (T.O CONC TOPP'G) EL 252.90' 12 .41' 1 .17' 8 .06' 1 .17' 9 .06' 1 .17' 3 .93' CRAWLSPACE (T.O CONC TOPP'G) EL 237.57' 6 .92 WINDOW HEADER 8 .00 WINDOW HEADER THIRDFLOOR (T.O CONC TOPP'G) EL 262.13' 33 .16 PR AVG BUILDING HEIGHT 12.17' 12.17' 24.33 (F) A 24.58 (C) B CCA6 D A7 154154.21' .21' 10 .61 12 10.9 LIVING KITCHEN BEDROOM1 BEDROOM MASTER BEDROOM CRAWLSPACE .2mLOWSLOPEEXCLUSION .3mLOWSLOPEEXCLUSION .83 3.97 .73 3.97 .83 SECTIONBB' SCALE:1/4"=1'-0 2.86 >0.7M .50 O/H .50 O/H 2.85 .7M 12 12 10.9 TOJ252.72' T/OPARAPET 253.47' .00 FIREPLACEO/H T/OJOIST 156.69' 4 .42 SILL HT LOADBEARINGWALL SUPPORTINGTRUSS LOADBEARINGWALL SUPPORTINGTRUSS D3 01 D4 03 01 D4 D4 04 R1 W2 .1 F2 W4 F1 W1 .1 F2 F2 R3 W2 F5W2 W1 10.7MHEIGHTLINE SG@PL 240.10' SG@PL 241.70' MAXHT 10.7M 240.10' 35.10' MAXHT 10.7M 241.70'+35.10' .937 [1.20m SOLIDSOFFIT REQ'DVBBL 9.10.15.5.(11) +3/4HRFRR RATINGREQ'D VBBL9.10.15.5.(3) 3.937 [1.20m SOLIDSOFFIT REQ'DVBBL .10.15.5.(11) +3/4HRFRR RATINGREQ'D VBBL .10.15.5.(3) 1212.17' .17' (F)24.33 A (C)24.58 CB A6 A7DC MAINFLOOR (T.O CONC TOPP'G) EL 242.67' ROOFPEAK (T.O SHEATHING) EL 274.54' SECONDFLOOR (T.O CONC TOPP'G) EL 252.90' 12 .41' 1 .17' 8 .06' 1 .17' 9 .06' 1 .17' 3 .93' CRAWLSPACE (T.O CONC TOPP'G) EL 237.57' 6 .92 WINDOW HEADER 8 .00 WINDOW HEADER THIRDFLOOR (T.O CONC TOPP'G) EL 262.13' 33 .16 PR AVG BUILDING HEIGHT 1 .19 HEEL HEIGHT 24.25 TRUSSSPAN 1.25TRUSSTHICKNESS MAINROOFTRUSS SCALE:1/2"=1'-0 12 10.9 C RIDGEBEAM REFERSTRUCTURALSET TRUSSESSEPARATION LINEATRIDGEBEAM 11.91 .44 11.91 1 .17 HEEL HEIGHT 1.31 TRUSS THICKNESS 22.10 TRUSSSPAN 12 A B DORMERROOFTRUSS SCALE:1/2"=1'-0 RIDGEBEAM REFERSTRUCTURALSET TRUSSESSEPARATION LINEATRIDGEBEAM 11.91 .44 .75 ROOFS:WALLS: MAINROOF ENG TRUSS[EFF R-30INSULATED] ASPHALTROOFINGW/RIDGEVENTon ROOFINGFELTW/LAPPED&STAGGEREDSEAMS; EAVEPROTECTIONPROVIDED12"BEYONDINSIDEFACEOFEXT WALL 5/8"PLYWOODSHEATHING(P.T orBORATE-TREATED) ENG'DTRUSSES2X@24"O.C (REF STRUCT INTERIORCONDITION 11"THICK[R-40]ECOTOUCHFIBREGLASSBATTINSULATION VENT@1:300 VENTEDROOFTHRUSOFFITSANDRIDGE MIN .5"CLEARAIRSPACEABOVEINSULATION 6MILPOLY(VB) 5/8"TYPE'X'GWB PAINTED SOFFITCONDITION (optional)1XWOODSTRIPSFURRINGFORSOFFITINSTALL 3/4"T&GSTAINED&SEALEDWOODSOFFITS 1/2"SCREENEDGAPBETWEENSOFFITBOARDSFORVENT PROVIDE1:300ROOFVENTINGCONTINOUSAROUNDROOF CANOPYROOFOVERINTERIOR [EFF R-30INSULATED] GRAVELBALLASTORLAVAROCKBALLAST(OPTIONAL)on 2LAYERSSBSBITUMINOUSTORCH-ONROOFING or90MILIBSINGLE-PLYROOFINGMEMBRANE 5/8"PLYWOODSHEATHING(P.T orBORATE-TREATED) RIPPED2XWOODSLEEPERS@16"O/CFORDRAINAGE&VENTING PERPENDICULARTOJOISTSBELOWW/VENTING(1:150)UPSIDEWALLSVENT 117/8"TJIJOISTS@16"O/C(REF STRUCT.) 11"THICK[R-40]ECOTOUCHFIBREGLASSBATTINSULATION MIN 2"CLEARAIRSPACEABOVEINSULATION 6MILPOLY(VB) 5/8"GWB PAINTED BELOWGRADEFLOORSLAB [EFF R-15INSULATED] FINISHEDFLOORINGW/SPEC UNDERLAYorPOLISHEDCONCRETE 4"REINFORCEDCONC SLAB(REF STRUCT 6MILPOLY(VB) SEALEDTOCONCRETEWALLW1ATPERIMETER 3"THICK[R-15]RIGIDINSULATION 6"DRAINGRAVEL COMPACTSTRUCTFILL SLABEDGEINSULATION: 3"[R-14]XPSRIGIDINSULATIONUNDER&ATSLABEDGE CANOPYROOFOVEREXTERIOR [UNINSULATED] GRAVELBALLASTORLAVAROCKBALLAST(OPTIONAL)on 2LAYERSSBSBITUMINOUSTORCH-ONROOFING or90MILIBSINGLE-PLYROOFINGMEMBRANE 5/8"PLYWOODSHEATHING(P.T orBORATE-TREATED) RIPPED2XWOODSLEEPERS@16"O/CFORDRAINAGE&VENTING PERPENDICULARTOJOISTSBELOWW/VENTING(1:150)UPSIDEWALLSVENT 117/8"TJIJOISTS@16"O/C(REF STRUCT.) 6MILPOLY(VB) (optional)1XWOODSTRIPSFURRINGFORSOFFITINSTALL 3/4"T&GSTAINED&SEALEDWOODSOFFITS INTERIORFLOOR [UNINSULATED] HARDWOODorTILEFINISHEDFLOORINGW/SPEC UNDERLAY 11/2"LIGHTWEIGHTCONCRETETOPPING 5/8" .FIRPLYWOODSUBFLOOR 117/8"TJIJOISTS@16"O.C (REF STRUCT.) W/ROXULSOUNDINSULATION(ASREQUIRED) 5/8"GWB PAINTED FOUNDATIONWALL [EFF R-22INSULATED] SANDORPARGEDCONCRETEIFREQUIRED(ABOVE-GRADE) DRAINAGEMAT&BITUM DAMPPROOFINGMEMBRANE(BELOW-GRADE) 8"REINFORCEDCONC WALL(AB)(REF STRUCT 21/2"THICK[R-12]XPSINSULATION 2X4WOODSTUDS@24"O.C SERVICECAVITY CAVITYFILLEDWITH3.5"THICK[R-14]ECOTOUCHFIBREGLASSBATTINSULATION 1/2"GWB PAINTED
[EFF R-22INSULATED] HZ5HARDIESHINGLE®CLADDING(ASPERCCMC12678-RREPORT)-REFELEVATIONS 1X3PLYWOODRAINSCREENSTRAPPING WRBBUILDINGWRAP(AB) LAPPED&TAPEDSEAMSINCL TAPETOTOPOFFOUNDATION&TOPOFWALLSHEATHING TYVEKorEQUIVALENT 1/2"EXT PLYWOODorOSBSHEATHING 2X8 .D WOODSTUDS@24"O.C FRAMING(REF STRUCT.) CAVITYFILLEDW/7.25"THICK[R-28]ECOTOUCHFIBREGLASSBATTINSULATION 6MILPOLY(VB) 1/2"GWB PAINTED
(<1.2MfromPL)REF
HZ5HARDIESHINGLE®CLADDING(ASPERCCMC12678-RREPORT)-REFELEVATIONS 1X3PLYWOODRAINSCREENSTRAPPING WRBBUILDINGWRAP(AB) LAPPED&TAPEDSEAMSINCL TAPETOTOPOFFOUNDATION&TOPOFWALLSHEATHING TYVEKorEQUIVALENT 1/2"EXT PLYWOODorOSBSHEATHING 2X8 .D WOODSTUDS@24"O.C FRAMING(REF STRUCT.) CAVITYFILLEDW/7.25"THICK[R-28]ROCKWOOLBATTNON-COMBUSTIBLEINSULATION 6MILPOLY(VB) 5/8"TYPE'X'GWB PAINTED FRRFOUNDATIONWALL [EFF R-22INSULATED] (<1.2MfromPL)REF A-9.10.3.1.AASSEMBLYW4(1HRFRR) SANDORPARGEDCONCRETEIFREQUIRED(ABOVE-GRADE) DRAINAGEMAT&BITUM DAMPPROOFINGMEMBRANE(BELOW-GRADE) 8"REINFORCEDCONC WALL(AB)(REF STRUCT 21/2"THICK[R-12]XPSINSULATION 2X4WOODSTUDS@24"O.C SERVICECAVITY CAVITYFILLEDWITH3.5"THICK[R-14]ROCKWOOLBATTINSULATION [NON-COMBUSTIBLE] 5/8"TYPE'X'GWB PAINTED FRRPARTYWALL [EFF R-22INSULATED] REF TABLED-2.3.4.A&D2.3.4.CFOR HRFRR REF A-9.10.3.1.A/W13aFORSTC57 5/8"TYPE-XGWB PAINTED 1/2"SHEATING(REF STRUCT.)FORSHEARASREQ'D 2X4 .D WOODSTUDS@16"O/C(400mm) FILLCAVITY .5"THICK[R-12]ROCKWOOLWOOLBATTINSULATION 1"AIRSPACE 2X4 .D WOODSTUDS@16"O/C(400mm) FILLCAVITY .5"THICK[R-12]ROCKWOOLBATTINSULATION[NON-COMBUSTIBLE] 1/2"SHEATING(REF STRUCT.)FORSHEARASREQ'D 5/8"TYPE-XGWB PAINTED INTERIORWALL-[UNINSULATED] 1/2"GWB PAINTED SHEARWALL 1/2"PLYWOODSHEATHING(REF STRUCT FORSHEARWALLS) 2X4or2X6STUDWALL@16"O.C (REF PLANS&SEESTRUCT FORSTUDSIZE) 1/2"GWB PAINTED(USEV/BPAINTINBATHROOMS) OPTIONALATBATHROOMS&BEDROOMS: FILLSTUDCAVITYW/ROXULSOUNDINSULATIONFORINCREASEDSTC RETAININGWALL [UNINSULATED] 6"OR8"REINFORCEDCONC WALL(REF STRUCT RIMJOISTCAVITY [INSULATED] CLADDING(SEEAPPLICABLEWALLASSEMBLIES) 1X3 .T PLYWOODRAINSCREENSTRAPPING TYVEKBUILDINGWRAP LAPPEDSEAMS(AB) 1/2"EXT PLYWOODorOSBSHEATHING 2XWOODorLVLRIMJOIST 7.25"THICK[R-28]ECOTOUCHFIBREGLASSBATTINSULATIONBET FLOORJOISTS EXTERIORPATIOCONCRETESLAB [UNINSULATED] BROOMFINISHCONCRETESKIMCOATSLOPEDTODRAIN 4"REINFORCEDCONCRETESLAB(REF STRUCT 6"DRAINGRAVELORCOMPACTSTRUCTURALFILL R1 ASSEMBLYLEGEND MAINHOUSE R3 R4 F1 FLOORS: F2 F3 W1 WALLS: W2 W2.1 W1.1 W3 W4 W5 TYP F4 EXTERIORDECKOVERINTERIOR[EFF R-30INSULATED] FINISHEDDECKINGONLEVELLERS 2LAYERSSBSBITUMINOUSTORCH-ONROOFING or90MILIBSINGLE-PLYROOFINGMEMBRANE 5/8"PLYWOODSHEATHING(P.T orBORATE-TREATED) RIPPED2XWOODSLEEPERS@16"O/CFORDRAINAGE&VENTING PERPENDICULARTOJOISTSBELOWW/VENTING(1:150)UPSIDEWALLSVENT 117/8"TJIJOISTS@16"O/C(REF STRUCT.) 11"THICK[R-40]ECOTOUCHFIBREGLASSBATTINSULATION MIN 2"CLEARAIRSPACEABOVEINSULATION 6MILPOLY(VB) 5/8"GWB PAINTED F5 FLOOROVEREXT (FIREPLACE)[EFF R-30INSULATED] HARDWOODorTILEFINISHEDFLOORINGW/SPEC UNDERLAY 11/2"LIGHTWEIGHTCONCRETETOPPING 5/8" .FIRPLYWOODSUBFLOOR 117/8"TJIJOISTS@16"O.C (REF STRUCT.) 11"THICK[R-40]ECOTOUCHFIBREGLASSBATTINSULATION 6MILPOLY(VB) (optional)1XWOODSTRIPSFURRINGFORSOFFITINSTALL 3/4"T&GSTAINED&SEALEDWOODSOFFITS SECTIONNOTES: 1 ASPERVBBL2019-REQUIREMENTSFORSTAIRS HANDRAILSANDGUARSTOCOMPLYWITHENTIRESECTIONSOF9.8.7 HANDRAILSAND9.8.8 GUARDS RISEBETWEEN125mm 200mm 4.92" 7.87" RUNBETWEEN255mm 355mm 10.04" 13.98" MINIMUM865mm[2'-10"]LANDING STAIRWIDTHFORLANEWAYHOUSE MINIMUM914mm[3'-0"]LANDING STAIRWIDTHFOR1/2FAMILYDWELLING MINIMUM1950mm[6'-5"]HEADROOMFORSTAIRSANDLANDING 2 NOMECHANICALEQUIPMENTSAREPERMITTEDINATTICFLOORSPACE

CANOPYROOFOVERINTERIOR

2882W35thAve Vancouver

Phone:(604)603-5820

GBSENGINEERINGGROUPLTD #14329HawkstreamDr Surrey BC V3W0N5 Phone:(604)599-8890

59FernwayDr, PortMoody BCV3H5K5 Phone:(604)362-7021

MYCORRHIZAURBANFORESTRY 1617783Ave Surrey BCV4N5T3 Phone:(778)222-6767

DOMUSHOMEENERGYINC 1556E5thAve#101 Vancouver BCV5N1L7 Phone:604-243-8616

BELOWGRADEFLOORSLAB-[EFF R-15INSULATED]

DUPLEX RESIDENCE 3517 WEST 23RD AVENUE CONSTRUCTION: DESIGN: 216 289 ALEXANDER STREET VANCOUVER BC V6A 4H6 PHONE: (604) 677 7877 | ARCHITRIXSTUDIO .COM drawings design legal property Design and cannot be used or reproduced without written consent Contractors must verify all site conditions and confirm all dimensions Dimensions given scaled dimensions NOTES & VERSIONS: DRAWNBY: 3517W23RD STARTDATE: STRUCTURALENGINEERING: GEOTECHNICALENGINEERING: ARBORIST: CEACONSULTANT: 2022 .09 .21_PRELIM FOR STRUCTURAL & CEA JOB#: SS KN MARCH2022 VANCOUVER B .C
BCV6N2M4
BUILDINGDIMENSIONNOTE: GRIDLINEDIMENSIONSARETOFACEOFSHEATHING FACEOFCONCRETE ADD .5"TOEACHSIDEFORFACEOFCLADDINGDIMENSION (C)FORDIMENSIONSTOCLADDING (F)FORDIMENSIONSTOFOUNDATION ROUGHOPENINGSNOTE: ALLTHEEXERIOROPENINGSDIMENSIONNOTESAREROUGHOPENINGS ALLTHEINTERIORDOORSAREOFFSET3"FROMSTUD .N.OONDRAWINGS SECTIONS A3.1 241.60' T/OPATIO242.67' BATH POWDER DENBATHBEDROOM1 BATH .86 O/HVARIES REFERPLAN BEDROOM BEDROOM COVERED DECK BEDROOM LIVING DINING 4.95 O/HVARIES REFERPLAN CRAWLSPACE CRAWLSPACE .00 O.H SECTIONDD' SCALE:1/4"=1'-0 6 .67 HEADER HT .58 SILL BATH .00 O.H 240.60' TOJ252.72' T/OPATIO242.67' TOD262.71' T/OPARAPET253.47' 8 .00 HEADER HT 6 .67 HEADER HT .58 SILL TOJ252.72' T/OPARAPET253.47' TOJ261.95' 1.50 O/H 1.50 O/H POWDER 8 .00 HEADER HT 1 .92 SILL HT 1 .92 SILL HT PATIOPATIO LAUNDRY LIVING DINING 3 .50 RAILING HT 3 .50 RAILING HT 6"PRE-FAB GRATEDRAIN 6"PRE-FAB GRATEDRAIN D5 01 D4 02 D4 05 02 D5 W2 W3 W1 R1 R1 F2 F1 W4 F2 W1 R1 W4 R4 F4 R4 W2 F2 F3F3 48.42 (C) 48.17 (F) 20.19 6.90 6.90 14.19 53 2 41 AA- B AMAINFLOOR (T.O CONC TOPP'G) EL 242.67' ROOFPEAK (T.O SHEATHING) EL 274.54' SECONDFLOOR (T.O CONC TOPP'G) EL 252.90' 12 .41' 1 .17' 8 .06' 1 .17' 9 .06' 1 .17' 3 .93' CRAWLSPACE (T.O CONC TOPP'G) EL 237.57' 6 .92 WINDOW HEADER 8 .00 WINDOW HEADER THIRDFLOOR (T.O CONC TOPP'G) EL 262.13' 33 .16 PR AVG BUILDING HEIGHT ROOFS:WALLS: MAINROOF-ENG TRUSS[EFF R-30INSULATED] ASPHALTROOFINGW/RIDGEVENTon ROOFINGFELTW/LAPPED&STAGGEREDSEAMS; EAVEPROTECTIONPROVIDED12"BEYONDINSIDEFACEOFEXT WALL 5/8"PLYWOODSHEATHING(P.T orBORATE-TREATED) ENG'DTRUSSES2X@24"O.C (REF STRUCT.) INTERIORCONDITION 11"THICK[R-40]ECOTOUCHFIBREGLASSBATTINSULATION VENT@1:300 VENTEDROOFTHRUSOFFITSANDRIDGE MIN .5"CLEARAIRSPACEABOVEINSULATION 6MILPOLY(VB) 5/8"TYPE'X'GWB PAINTED SOFFITCONDITION (optional)1XWOODSTRIPSFURRINGFORSOFFITINSTALL 3/4"T&GSTAINED&SEALEDWOODSOFFITS 1/2"SCREENEDGAPBETWEENSOFFITBOARDSFORVENT PROVIDE1:300ROOFVENTINGCONTINOUSAROUNDROOF
[EFF R-30INSULATED] GRAVELBALLASTORLAVAROCKBALLAST(OPTIONAL)on LAYERSSBSBITUMINOUSTORCH-ONROOFING or90MILIBSINGLE-PLYROOFINGMEMBRANE 5/8"PLYWOODSHEATHING(P.T orBORATE-TREATED) RIPPED2XWOODSLEEPERS@16"O/CFORDRAINAGE&VENTING PERPENDICULARTOJOISTSBELOWW/VENTING(1:150)UPSIDEWALLSVENT 117/8"TJIJOISTS@16"O/C(REF STRUCT 11"THICK[R-40]ECOTOUCHFIBREGLASSBATTINSULATION MIN 2"CLEARAIRSPACEABOVEINSULATION 6MILPOLY(VB) 5/8"GWB PAINTED
FINISHEDFLOORINGW/SPEC UNDERLAYorPOLISHEDCONCRETE 4"REINFORCEDCONC SLAB(REF STRUCT.) 6MILPOLY(VB) SEALEDTOCONCRETEWALLW1ATPERIMETER 3"THICK[R-15]RIGIDINSULATION 6"DRAINGRAVEL COMPACTSTRUCTFILL SLABEDGEINSULATION: 3"[R-14]XPSRIGIDINSULATIONUNDER&ATSLABEDGE CANOPYROOFOVEREXTERIOR [UNINSULATED] GRAVELBALLASTORLAVAROCKBALLAST(OPTIONAL)on LAYERSSBSBITUMINOUSTORCH-ONROOFING or90MILIBSINGLE-PLYROOFINGMEMBRANE 5/8"PLYWOODSHEATHING(P.T orBORATE-TREATED) RIPPED2XWOODSLEEPERS@16"O/CFORDRAINAGE&VENTING PERPENDICULARTOJOISTSBELOWW/VENTING(1:150)UPSIDEWALLSVENT 117/8"TJIJOISTS@16"O/C(REF STRUCT 6MILPOLY(VB) (optional)1XWOODSTRIPSFURRINGFORSOFFITINSTALL 3/4"T&GSTAINED&SEALEDWOODSOFFITS INTERIORFLOOR [UNINSULATED] HARDWOODorTILEFINISHEDFLOORINGW/SPEC UNDERLAY 1/2"LIGHTWEIGHTCONCRETETOPPING 5/8" .FIRPLYWOODSUBFLOOR 117/8"TJIJOISTS@16"O.C (REF STRUCT W/ROXULSOUNDINSULATION(ASREQUIRED) 5/8"GWB PAINTED FOUNDATIONWALL-[EFF R-22INSULATED] SANDORPARGEDCONCRETEIFREQUIRED(ABOVE-GRADE) DRAINAGEMAT&BITUM DAMPPROOFINGMEMBRANE(BELOW-GRADE) 8"REINFORCEDCONC WALL(AB)(REF STRUCT.) 1/2"THICK[R-12]XPSINSULATION 2X4WOODSTUDS@24"O.C SERVICECAVITY CAVITYFILLEDWITH .5"THICK[R-14]ECOTOUCHFIBREGLASSBATTINSULATION 1/2"GWB PAINTED EXTERIORWALL [EFF R-22INSULATED] HZ5HARDIESHINGLE®CLADDING(ASPERCCMC12678-RREPORT)-REFELEVATIONS 1X3PLYWOODRAINSCREENSTRAPPING WRBBUILDINGWRAP(AB) LAPPED&TAPEDSEAMSINCL TAPETOTOPOFFOUNDATION&TOPOFWALLSHEATHING TYVEKorEQUIVALENT 1/2"EXT PLYWOODorOSBSHEATHING 2X8K.D WOODSTUDS@24"O.C FRAMING(REF STRUCT.) CAVITYFILLEDW/7.25"THICK[R-28]ECOTOUCHFIBREGLASSBATTINSULATION 6MILPOLY(VB) 1/2"GWB PAINTED FRREXTERIORWALL [EFF R-22INSULATED] (<1.2MfromPL)REF A-9.10.3.1.AASSEMBLYW2(1HRFRR) HZ5HARDIESHINGLE®CLADDING(ASPERCCMC12678-RREPORT)-REFELEVATIONS 1X3PLYWOODRAINSCREENSTRAPPING WRBBUILDINGWRAP(AB) LAPPED&TAPEDSEAMSINCL TAPETOTOPOFFOUNDATION&TOPOFWALLSHEATHING TYVEKorEQUIVALENT 1/2"EXT PLYWOODorOSBSHEATHING 2X8K.D WOODSTUDS@24"O.C FRAMING(REF STRUCT.) CAVITYFILLEDW/7.25"THICK[R-28]ROCKWOOLBATTNON-COMBUSTIBLEINSULATION 6MILPOLY(VB) 5/8"TYPE'X'GWB PAINTED FRRFOUNDATIONWALL-[EFF R-22INSULATED] (<1.2MfromPL)REF A-9.10.3.1.AASSEMBLYW4(1HRFRR) SANDORPARGEDCONCRETEIFREQUIRED(ABOVE-GRADE) DRAINAGEMAT&BITUM DAMPPROOFINGMEMBRANE(BELOW-GRADE) 8"REINFORCEDCONC WALL(AB)(REF STRUCT.) 1/2"THICK[R-12]XPSINSULATION 2X4WOODSTUDS@24"O.C SERVICECAVITY CAVITYFILLEDWITH .5"THICK[R-14]ROCKWOOLBATTINSULATION [NON-COMBUSTIBLE] 5/8"TYPE'X'GWB PAINTED FRRPARTYWALL [EFF R-22INSULATED] REF TABLED-2.3.4.A&D2.3.4.CFOR1HRFRR REF A-9.10.3.1.A/W13aFORSTC57 5/8"TYPE-XGWB PAINTED 1/2"SHEATING(REF STRUCT.)FORSHEARASREQ'D 2X4K.D WOODSTUDS@16"O/C(400mm) FILLCAVITY .5"THICK[R-12]ROCKWOOLWOOLBATTINSULATION 1"AIRSPACE 2X4K.D WOODSTUDS@16"O/C(400mm) FILLCAVITY .5"THICK[R-12]ROCKWOOLBATTINSULATION[NON-COMBUSTIBLE] 1/2"SHEATING(REF STRUCT.)FORSHEARASREQ'D 5/8"TYPE-XGWB PAINTED INTERIORWALL-[UNINSULATED] 1/2"GWB PAINTED SHEARWALL 1/2"PLYWOODSHEATHING(REF STRUCT FORSHEARWALLS) 2X4or2X6STUDWALL@16"O.C (REF PLANS SEESTRUCT FORSTUDSIZE) 1/2"GWB PAINTED(USEV/BPAINTINBATHROOMS) OPTIONALATBATHROOMS&BEDROOMS: FILLSTUDCAVITYW/ROXULSOUNDINSULATIONFORINCREASEDSTC RETAININGWALL [UNINSULATED] 6"OR8"REINFORCEDCONC WALL(REF STRUCT RIMJOISTCAVITY-[INSULATED] CLADDING(SEEAPPLICABLEWALLASSEMBLIES) 1X3 .T PLYWOODRAINSCREENSTRAPPING TYVEKBUILDINGWRAP LAPPEDSEAMS(AB) 1/2"EXT PLYWOODorOSBSHEATHING 2XWOODorLVLRIMJOIST .25"THICK[R-28]ECOTOUCHFIBREGLASSBATTINSULATIONBET FLOORJOISTS EXTERIORPATIOCONCRETESLAB [UNINSULATED] BROOMFINISHCONCRETESKIMCOATSLOPEDTODRAIN 4"REINFORCEDCONCRETESLAB(REF STRUCT.) 6"DRAINGRAVELORCOMPACTSTRUCTURALFILL R1 ASSEMBLYLEGEND-MAINHOUSE R3 R4 F1 FLOORS: F2 F3 W1 WALLS: W2 W2.1 W1.1 W3 W4 W5 TYP F4 EXTERIORDECKOVERINTERIOR[EFF R-30INSULATED] FINISHEDDECKINGONLEVELLERS LAYERSSBSBITUMINOUSTORCH-ONROOFING or90MILIBSINGLE-PLYROOFINGMEMBRANE 5/8"PLYWOODSHEATHING(P.T orBORATE-TREATED) RIPPED2XWOODSLEEPERS@16"O/CFORDRAINAGE&VENTING PERPENDICULARTOJOISTSBELOWW/VENTING(1:150)UPSIDEWALLSVENT 117/8"TJIJOISTS@16"O/C(REF STRUCT 11"THICK[R-40]ECOTOUCHFIBREGLASSBATTINSULATION MIN 2"CLEARAIRSPACEABOVEINSULATION 6MILPOLY(VB) 5/8"GWB PAINTED F5 FLOOROVEREXT (FIREPLACE)[EFF R-30INSULATED] HARDWOODorTILEFINISHEDFLOORINGW/SPEC UNDERLAY 1/2"LIGHTWEIGHTCONCRETETOPPING 5/8" .FIRPLYWOODSUBFLOOR 117/8"TJIJOISTS@16"O.C (REF STRUCT 11"THICK[R-40]ECOTOUCHFIBREGLASSBATTINSULATION 6MILPOLY(VB) (optional)1XWOODSTRIPSFURRINGFORSOFFITINSTALL 3/4"T&GSTAINED&SEALEDWOODSOFFITS

CANOPYROOFOVEREXTERIOR [UNINSULATED] GRAVELBALLASTORLAVAROCKBALLAST(OPTIONAL)on

2882W35thAve

Phone:(604)603-5820

GBSENGINEERINGGROUPLTD #14329HawkstreamDr Surrey BC V3W0N5 Phone:(604)599-8890

59FernwayDr, PortMoody BCV3H5K5 Phone:(604)362-7021

MYCORRHIZAURBANFORESTRY 1617783Ave Surrey BCV4N5T3 Phone:(778)222-6767

DOMUSHOMEENERGYINC 1556E5thAve#101 Vancouver BCV5N1L7 Phone:604-243-8616

F5 FLOOROVEREXT (FIREPLACE)[EFF R-30INSULATED]

DUPLEX RESIDENCE 3517 WEST 23RD AVENUE CONSTRUCTION: DESIGN: 216 289 ALEXANDER STREET VANCOUVER BC V6A 4H6 PHONE: (604) 677 7877 | ARCHITRIXSTUDIO .COM drawings design legal property Design and cannot be used or reproduced without written consent Contractors must verify all site conditions and confirm all dimensions Dimensions given scaled dimensions NOTES & VERSIONS: DRAWNBY: 3517W23RD STARTDATE: STRUCTURALENGINEERING: GEOTECHNICALENGINEERING: ARBORIST: CEACONSULTANT: 2022 .09 .21_PRELIM FOR STRUCTURAL & CEA JOB#: SS KN MARCH2022 VANCOUVER B .C
Vancouver BCV6N2M4
BUILDINGDIMENSIONNOTE: GRIDLINEDIMENSIONSARETOFACEOFSHEATHING FACEOFCONCRETE ADD .5"TOEACHSIDEFORFACEOFCLADDINGDIMENSION (C)FORDIMENSIONSTOCLADDING (F)FORDIMENSIONSTOFOUNDATION ROUGHOPENINGSNOTE: ALLTHEEXERIOROPENINGSDIMENSIONNOTESAREROUGHOPENINGS ALLTHEINTERIORDOORSAREOFFSET3"FROMSTUD .N.OONDRAWINGS SECTIONS A3.2 241.60' 240.60' KITCHEN BEDROOM2 STAIRWELL LOWCEILINGVOIDSPACE UNDERSLOPINGROOF CLOSET CRAWLSPACE KITCHEN STAIRWELL CRAWLSPACE BATHBEDROOM .00 O.H SECTIONCC' SCALE:1/4"=1'-0 LOWCEILINGVOIDSPACE UNDERSLOPINGROOF T/OPATIO242.67' T/OPATIO242.67' 8 .00 HEADER HT 8 .00 HEADER HT .91 O/HVARIES REFERPLAN 5.91 O/HVARIES REFERPLAN TOJ252.72' T/OPARAPET253.47' TOJ252.72' T/OPARAPET253.47' 1.50 O/H 1.50 O/H PORCH PORCH ENTRY FOYER 6"PRE-FAB GRATEDRAIN 6"PRE-FAB GRATEDRAIN W3W2 W1 R1 R1 F2 F1 W4 F2 W2 W1 R1 W2W2 R4 F3F2 F3 R4 (C)48.42 (F)48.17 620.196.9014.90 .19 3 125 4AA-BA MAINFLOOR (T.O CONC TOPP'G) EL 242.67' ROOFPEAK (T.O SHEATHING) EL 274.54' SECONDFLOOR (T.O CONC TOPP'G) EL 252.90' 12 .41' 1 .17' 8 .06' 1 .17' 9 .06' 1 .17' 3 .93' CRAWLSPACE (T.O CONC TOPP'G) EL 237.57' 6 .92 WINDOW HEADER 8 .00 WINDOW HEADER THIRDFLOOR (T.O CONC TOPP'G) EL 262.13' 33 .16 PR AVG BUILDING HEIGHT ROOFS:WALLS: MAINROOF-ENG TRUSS[EFF R-30INSULATED] ASPHALTROOFINGW/RIDGEVENTon ROOFINGFELTW/LAPPED&STAGGEREDSEAMS; EAVEPROTECTIONPROVIDED12"BEYONDINSIDEFACEOFEXT WALL 5/8"PLYWOODSHEATHING(P.T orBORATE-TREATED) ENG'DTRUSSES2X@24"O.C (REF STRUCT.) INTERIORCONDITION 11"THICK[R-40]ECOTOUCHFIBREGLASSBATTINSULATION VENT@1:300 VENTEDROOFTHRUSOFFITSANDRIDGE MIN .5"CLEARAIRSPACEABOVEINSULATION 6MILPOLY(VB) 5/8"TYPE'X'GWB PAINTED SOFFITCONDITION (optional)1XWOODSTRIPSFURRINGFORSOFFITINSTALL 3/4"T&GSTAINED&SEALEDWOODSOFFITS 1/2"SCREENEDGAPBETWEENSOFFITBOARDSFORVENT PROVIDE1:300ROOFVENTINGCONTINOUSAROUNDROOF CANOPYROOFOVERINTERIOR [EFF R-30INSULATED] GRAVELBALLASTORLAVAROCKBALLAST(OPTIONAL)on LAYERSSBSBITUMINOUSTORCH-ONROOFING or90MILIBSINGLE-PLYROOFINGMEMBRANE 5/8"PLYWOODSHEATHING(P.T orBORATE-TREATED) RIPPED2XWOODSLEEPERS@16"O/CFORDRAINAGE&VENTING PERPENDICULARTOJOISTSBELOWW/VENTING(1:150)UPSIDEWALLSVENT 117/8"TJIJOISTS@16"O/C(REF STRUCT 11"THICK[R-40]ECOTOUCHFIBREGLASSBATTINSULATION MIN 2"CLEARAIRSPACEABOVEINSULATION 6MILPOLY(VB) 5/8"GWB PAINTED BELOWGRADEFLOORSLAB-[EFF R-15INSULATED] FINISHEDFLOORINGW/SPEC UNDERLAYorPOLISHEDCONCRETE 4"REINFORCEDCONC SLAB(REF STRUCT.) 6MILPOLY(VB) SEALEDTOCONCRETEWALLW1ATPERIMETER 3"THICK[R-15]RIGIDINSULATION 6"DRAINGRAVEL COMPACTSTRUCTFILL SLABEDGEINSULATION: 3"[R-14]XPSRIGIDINSULATIONUNDER&ATSLABEDGE
LAYERSSBSBITUMINOUSTORCH-ONROOFING or90MILIBSINGLE-PLYROOFINGMEMBRANE 5/8"PLYWOODSHEATHING(P.T orBORATE-TREATED) RIPPED2XWOODSLEEPERS@16"O/CFORDRAINAGE&VENTING PERPENDICULARTOJOISTSBELOWW/VENTING(1:150)UPSIDEWALLSVENT 117/8"TJIJOISTS@16"O/C(REF STRUCT 6MILPOLY(VB) (optional)1XWOODSTRIPSFURRINGFORSOFFITINSTALL 3/4"T&GSTAINED&SEALEDWOODSOFFITS INTERIORFLOOR [UNINSULATED] HARDWOODorTILEFINISHEDFLOORINGW/SPEC UNDERLAY 1/2"LIGHTWEIGHTCONCRETETOPPING 5/8" .FIRPLYWOODSUBFLOOR 117/8"TJIJOISTS@16"O.C (REF STRUCT W/ROXULSOUNDINSULATION(ASREQUIRED) 5/8"GWB PAINTED FOUNDATIONWALL-[EFF R-22INSULATED] SANDORPARGEDCONCRETEIFREQUIRED(ABOVE-GRADE) DRAINAGEMAT&BITUM DAMPPROOFINGMEMBRANE(BELOW-GRADE) 8"REINFORCEDCONC WALL(AB)(REF STRUCT.) 1/2"THICK[R-12]XPSINSULATION 2X4WOODSTUDS@24"O.C SERVICECAVITY CAVITYFILLEDWITH .5"THICK[R-14]ECOTOUCHFIBREGLASSBATTINSULATION 1/2"GWB PAINTED EXTERIORWALL [EFF R-22INSULATED] HZ5HARDIESHINGLE®CLADDING(ASPERCCMC12678-RREPORT)-REFELEVATIONS 1X3PLYWOODRAINSCREENSTRAPPING WRBBUILDINGWRAP(AB) LAPPED&TAPEDSEAMSINCL TAPETOTOPOFFOUNDATION&TOPOFWALLSHEATHING TYVEKorEQUIVALENT 1/2"EXT PLYWOODorOSBSHEATHING 2X8K.D WOODSTUDS@24"O.C FRAMING(REF STRUCT.) CAVITYFILLEDW/7.25"THICK[R-28]ECOTOUCHFIBREGLASSBATTINSULATION 6MILPOLY(VB) 1/2"GWB PAINTED FRREXTERIORWALL [EFF R-22INSULATED] (<1.2MfromPL)REF A-9.10.3.1.AASSEMBLYW2(1HRFRR) HZ5HARDIESHINGLE®CLADDING(ASPERCCMC12678-RREPORT)-REFELEVATIONS 1X3PLYWOODRAINSCREENSTRAPPING WRBBUILDINGWRAP(AB) LAPPED&TAPEDSEAMSINCL TAPETOTOPOFFOUNDATION&TOPOFWALLSHEATHING TYVEKorEQUIVALENT 1/2"EXT PLYWOODorOSBSHEATHING 2X8K.D WOODSTUDS@24"O.C FRAMING(REF STRUCT.) CAVITYFILLEDW/7.25"THICK[R-28]ROCKWOOLBATTNON-COMBUSTIBLEINSULATION 6MILPOLY(VB) 5/8"TYPE'X'GWB PAINTED FRRFOUNDATIONWALL-[EFF R-22INSULATED] (<1.2MfromPL)REF A-9.10.3.1.AASSEMBLYW4(1HRFRR) SANDORPARGEDCONCRETEIFREQUIRED(ABOVE-GRADE) DRAINAGEMAT&BITUM DAMPPROOFINGMEMBRANE(BELOW-GRADE) 8"REINFORCEDCONC WALL(AB)(REF STRUCT.) 1/2"THICK[R-12]XPSINSULATION 2X4WOODSTUDS@24"O.C SERVICECAVITY CAVITYFILLEDWITH .5"THICK[R-14]ROCKWOOLBATTINSULATION [NON-COMBUSTIBLE] 5/8"TYPE'X'GWB PAINTED FRRPARTYWALL [EFF R-22INSULATED] REF TABLED-2.3.4.A&D2.3.4.CFOR1HRFRR REF A-9.10.3.1.A/W13aFORSTC57 5/8"TYPE-XGWB PAINTED 1/2"SHEATING(REF STRUCT.)FORSHEARASREQ'D 2X4K.D WOODSTUDS@16"O/C(400mm) FILLCAVITY .5"THICK[R-12]ROCKWOOLWOOLBATTINSULATION 1"AIRSPACE 2X4K.D WOODSTUDS@16"O/C(400mm) FILLCAVITY .5"THICK[R-12]ROCKWOOLBATTINSULATION[NON-COMBUSTIBLE] 1/2"SHEATING(REF STRUCT.)FORSHEARASREQ'D 5/8"TYPE-XGWB PAINTED INTERIORWALL-[UNINSULATED] 1/2"GWB PAINTED SHEARWALL 1/2"PLYWOODSHEATHING(REF STRUCT FORSHEARWALLS) 2X4or2X6STUDWALL@16"O.C (REF PLANS SEESTRUCT FORSTUDSIZE) 1/2"GWB PAINTED(USEV/BPAINTINBATHROOMS) OPTIONALATBATHROOMS&BEDROOMS: FILLSTUDCAVITYW/ROXULSOUNDINSULATIONFORINCREASEDSTC RETAININGWALL [UNINSULATED] 6"OR8"REINFORCEDCONC WALL(REF STRUCT RIMJOISTCAVITY-[INSULATED] CLADDING(SEEAPPLICABLEWALLASSEMBLIES) 1X3 .T PLYWOODRAINSCREENSTRAPPING TYVEKBUILDINGWRAP LAPPEDSEAMS(AB) 1/2"EXT PLYWOODorOSBSHEATHING 2XWOODorLVLRIMJOIST .25"THICK[R-28]ECOTOUCHFIBREGLASSBATTINSULATIONBET FLOORJOISTS EXTERIORPATIOCONCRETESLAB [UNINSULATED] BROOMFINISHCONCRETESKIMCOATSLOPEDTODRAIN 4"REINFORCEDCONCRETESLAB(REF STRUCT.) 6"DRAINGRAVELORCOMPACTSTRUCTURALFILL R1 ASSEMBLYLEGEND-MAINHOUSE R3 R4 F1 FLOORS: F2 F3 W1 WALLS: W2 W2.1 W1.1 W3 W4 W5 TYP F4 EXTERIORDECKOVERINTERIOR[EFF R-30INSULATED] FINISHEDDECKINGONLEVELLERS LAYERSSBSBITUMINOUSTORCH-ONROOFING or90MILIBSINGLE-PLYROOFINGMEMBRANE 5/8"PLYWOODSHEATHING(P.T orBORATE-TREATED) RIPPED2XWOODSLEEPERS@16"O/CFORDRAINAGE&VENTING PERPENDICULARTOJOISTSBELOWW/VENTING(1:150)UPSIDEWALLSVENT 117/8"TJIJOISTS@16"O/C(REF STRUCT 11"THICK[R-40]ECOTOUCHFIBREGLASSBATTINSULATION MIN 2"CLEARAIRSPACEABOVEINSULATION 6MILPOLY(VB) 5/8"GWB PAINTED
HARDWOODorTILEFINISHEDFLOORINGW/SPEC UNDERLAY 1/2"LIGHTWEIGHTCONCRETETOPPING 5/8" .FIRPLYWOODSUBFLOOR 117/8"TJIJOISTS@16"O.C (REF STRUCT 11"THICK[R-40]ECOTOUCHFIBREGLASSBATTINSULATION 6MILPOLY(VB) (optional)1XWOODSTRIPSFURRINGFORSOFFITINSTALL 3/4"T&GSTAINED&SEALEDWOODSOFFITS

Phone:(604)603-5820

GBSENGINEERINGGROUPLTD #14329HawkstreamDr Surrey BC V3W0N5 Phone:(604)599-8890

59FernwayDr, PortMoody BCV3H5K5 Phone:(604)362-7021

MYCORRHIZAURBANFORESTRY 1617783Ave Surrey BCV4N5T3 Phone:(778)222-6767

DOMUSHOMEENERGYINC 1556E5thAve#101 Vancouver BCV5N1L7 Phone:604-243-8616

DUPLEX RESIDENCE 3517 WEST 23RD AVENUE CONSTRUCTION: DESIGN: 216 289 ALEXANDER STREET VANCOUVER BC V6A 4H6 PHONE: (604) 677 7877 | ARCHITRIXSTUDIO .COM drawings design legal property Design and cannot be used or reproduced without written consent Contractors must verify all site conditions and confirm all dimensions Dimensions given scaled dimensions NOTES & VERSIONS: DRAWNBY: 3517W23RD STARTDATE: STRUCTURALENGINEERING: GEOTECHNICALENGINEERING: ARBORIST: CEACONSULTANT: 2022 .09 .21_PRELIM FOR STRUCTURAL & CEA JOB#: SS KN MARCH2022 VANCOUVER B .C 2882W35thAve Vancouver BCV6N2M4
BUILDINGDIMENSIONNOTE: GRIDLINEDIMENSIONSARETOFACEOFSHEATHING FACEOFCONCRETE ADD .5"TOEACHSIDEFORFACEOFCLADDINGDIMENSION (C)FORDIMENSIONSTOCLADDING (F)FORDIMENSIONSTOFOUNDATION ROUGHOPENINGSNOTE: ALLTHEEXERIOROPENINGSDIMENSIONNOTESAREROUGHOPENINGS ALLTHEINTERIORDOORSAREOFFSET3"FROMSTUD .N.OONDRAWINGS ELEVATIONS A4.0 NORTHELEVATION SCALE:1/4"=1'-0 7 S/G SLIDER 3 EX241.80' PR241.60' EX242.60' PR241.60' 12 4 .00 O/H 12 4 1.50 O/H .50 O/H 12 10.9 12 10.9 .00 O/H T/OPARAPET253.47' 6 .67 DOOR HEADER .58 SILL 3 .50 GUARD RAIL S/G 12 S/G SLIDER 8 S/G TOC242.67' 2 12 79 2 9 7 1 5 1 5 108 16 2 15 14 10.7MHEIGHTLINE SG@PL 240.10' SG@PL 241.70' MAXHT 10.7M 240.10'+35.10' MAXHT 10.7M 241.70' 35.10' .937 [1.20m SOLIDSOFFIT REQ'DVBBL 9.10.15.5.(11) 3/4HRFRR RATINGREQ'D VBBL .10.15.5.(3) 3.937 [1.20m SOLIDSOFFIT REQ'DVBBL .10.15.5.(11) +3/4HRFRR RATINGREQ'D VBBL9.10.15.5.(3) MAINFLOOR (T.O CONC TOPP'G) EL 242.67' ROOFPEAK (T.O SHEATHING) EL 274.54' SECONDFLOOR (T.O CONC TOPP'G) EL 252.90' 12 .41' 1 .17' 8 .06' 1 .17' 9 .06' 1 .17' 3 .93' CRAWLSPACE (T.O CONC TOPP'G) EL 237.57' 6 .92 WINDOW HEADER 8 .00 WINDOW HEADER THIRDFLOOR (T.O CONC TOPP'G) EL 262.13' 33 .16 PR AVG BUILDING HEIGHT 12.17' 12.17' 24.33 (F) A 24.58 (C) B CCA6 D A7 SOUTHELEVATION SCALE:1/4"=1'-0 5 5 S/G 12 S/G SLIDER 1 S/G EX240.10' PR240.60' 1 EX241.60' PR240.60'240.10' 241.70' 12 10.9 1.50 O/H .50 O/H 12 10.9 12 12 4 .00 O/H 1.00 O/H T/OPARAPET253.47' 3 .50 GUARD RAIL TOC242.67' 6 S/G SLIDER 6 .67 DOOR HEADER .58 SILL 10.7MHEIGHTLINE SG@PL 240.10' SG@PL 241.70' MAXHT 10.7M 240.10' 35.10' MAXHT 10.7M 241.70'+35.10' .937 [1.20m SOLIDSOFFIT REQ'DVBBL 9.10.15.5.(11) +3/4HRFRR RATINGREQ'D VBBL9.10.15.5.(3) 3.937 [1.20m SOLIDSOFFIT REQ'DVBBL .10.15.5.(11) +3/4HRFRR RATINGREQ'D VBBL .10.15.5.(3) 1212.17' .17' (F)24.33 A (C)24.58 CB A6 A7DC MAINFLOOR (T.O CONC TOPP'G) EL 242.67' ROOFPEAK (T.O SHEATHING) EL 274.54' SECONDFLOOR (T.O CONC TOPP'G) EL 252.90' 12 .41' 1 .17' 8 .06' 1 .17' 9 .06' 1 .17' 3 .93' CRAWLSPACE (T.O CONC TOPP'G) EL 237.57' 6 .92 WINDOW HEADER 8 .00 WINDOW HEADER THIRDFLOOR (T.O CONC TOPP'G) EL 262.13' 33 .16 PR AVG BUILDING HEIGHT TYPICALMATERIALSLEGEND-MAINHOUSE 1 CUSTOMPAINTEDHARDIESHINGLES-LACEDCORNERS 2 T&GHEMLOCKFINELINESIDING 3 ASPHALTROOF 4 'FINELINE'T&GSIDING&SOFFIT 4"EXPOSURE STAINED 5 2X10METALCLADFASCIAANDBARGEBOARDS 6 METALPANELWITH1/4"REVEALS 7 METALTRIMS CORNERBREAKSHAPES CAP&BASEFLASHING 8 HIGHPERFORMANCESLIDINGDOORS 9 VINYLWINDOWS 10 CLEARSTAINEDVGFIRFRONTDOOR MULTI-POINTHARDWARE 11 TRIPLEGLAZEDSKYLIGHTS 12 METALGRATERAILING FACEMOUNTEDWHEREPOSSIBLE 13 CONTINIOUSMINIMALGUTTERS 14 3"ROUNDMETALDOWNSPOUTS POWDERCOATED 15 CONCRETEWALLS PARGEANDPAINTASREQUIRED 16 CASTINPLACECONCRETESTAIRS SMOOTHFACEFINISH ELEVATIONNOTES: 1 ASPERVBBL9.10.15.4(8)THEMAXIMUMAGGREGATEAREAOFUNPROTECTED OPENINGSMAYBENOMORETHANTWICETHEAREAASDETERMINEDINTABLE 9.10.15.4 PROVIDEDALLROOMS INCLUDINGCLOSETSANDBATHROOMS THAT AREADAJACENTTOTHEEXPOSINGFACEANDTHATHAVEUNPROTECTED OPENINGSSHALLBESPRINKLERED NOTWITHSTANDINGANYEXEMPTIONSIN THESPRINKLERSTANDARDSREFERENCEDINARTICLE3.2.5.12 2 ROOFSOFFITSLOCATEDWITHIN1.2mOFAPROPERTYLINESHALLHAVENO OPENINGSANDCOMPLYWTHVBBL20199.10.15.5(11)

SPATIALCALCULATION: EASTELEVATION

TYPICALMATERIALSLEGEND-MAINHOUSE

SPATIALCALCULATION: WESTELEVATION

GBSENGINEERINGGROUPLTD #14329HawkstreamDr

BC V3W0N5 Phone:(604)599-8890

59FernwayDr, PortMoody BCV3H5K5 Phone:(604)362-7021

MYCORRHIZAURBANFORESTRY 1617783Ave Surrey BCV4N5T3 Phone:(778)222-6767

DOMUSHOMEENERGYINC 1556E5thAve#101 Vancouver BCV5N1L7 Phone:604-243-8616

DUPLEX RESIDENCE 3517 WEST 23RD AVENUE CONSTRUCTION: DESIGN: 216 289 ALEXANDER STREET VANCOUVER BC V6A 4H6 PHONE: (604) 677 7877 | ARCHITRIXSTUDIO .COM drawings design legal property Design and cannot be used or reproduced without written consent Contractors must verify all site conditions and confirm all dimensions Dimensions given scaled dimensions NOTES & VERSIONS: DRAWNBY: 3517W23RD STARTDATE: STRUCTURALENGINEERING: GEOTECHNICALENGINEERING: ARBORIST: CEACONSULTANT: 2022 .09 .21_PRELIM FOR STRUCTURAL & CEA JOB#: SS KN MARCH2022 VANCOUVER B .C 2882W35thAve Vancouver BCV6N2M4 Phone:(604)603-5820
Surrey
BUILDINGDIMENSIONNOTE: GRIDLINEDIMENSIONSARETOFACEOFSHEATHING FACEOFCONCRETE ADD .5"TOEACHSIDEFORFACEOFCLADDINGDIMENSION (C)FORDIMENSIONSTOCLADDING (F)FORDIMENSIONSTOFOUNDATION ROUGHOPENINGSNOTE: ALLTHEEXERIOROPENINGSDIMENSIONNOTESAREROUGHOPENINGS ALLTHEINTERIORDOORSAREOFFSET3"FROMSTUD .N.OONDRAWINGS ELEVATIONS A4.1 .94 O/H[CL TOCL.] 3.94 O/H[CL TOCL 1.97 VARIES .97 VARIES 4 .61 SILL HT 4 .61 SILL HT TOC242.67' 5 EASTELEVATION SCALE:1/4"=1'-0 T/OPATIO155.70' 1.50 O/H .00 O/H T/OPARAPET253.47' .50 O/H .00 O/H FLUSH HDR SKYLIGHT EX240.10' PR240.60' EX241.80' PR241.60' 241.60' 242.67' T/OPARAPET253.47' T/OPATIO242.67' 6 FROSTED 2 .00 SILL SKYLIGHT NOTE: FIRE-RATEDASSEMBLYW2.1 REFERSECTIONBB'AND ASSEMBLYLEGENDONA3.0 NOTE: FIRE-RATEDASSEMBLYW2.1 REFERSECTIONBB'AND ASSEMBLYLEGENDONA3.0 2 .00 SILL 5 230.60' 2 3 FLUSH HDR FROSTED 5 48.42 (C) 48.17 (F) 20.19 6.90 6.90 14.19 53 2 41 AA- B AMAINFLOOR (T.O CONC TOPP'G) EL 242.67' ROOFPEAK (T.O SHEATHING) EL 274.54' SECONDFLOOR (T.O CONC TOPP'G) EL 252.90' 12 .41' 1 .17' 8 .06' 1 .17' 9 .06' 1 .17' 3 .93' CRAWLSPACE (T.O CONC TOPP'G) EL 237.57' 6 .92 WINDOW HEADER 8 .00 WINDOW HEADER THIRDFLOOR (T.O CONC TOPP'G) EL 262.13' 33 .16 PR AVG BUILDING HEIGHT 3 .70 CLEAR LANDING DIST 2 .11 SILL 3 .00 CLEAR LANDING DIST 2 .11 SILL 3 .00 CLEAR LANDING DIST .90 O/H[CL TOCL.] 9 .23 SILL 3 .70 CLEAR LANDING DIST 9 .23 SILL 5.90 O/H[CL TOCL 230.60' WESTELEVATION SCALE:1/4"=1'-0 S/G 2 S/G WATER CURTAIN .50 O/H 1.00 O/H T/OPARAPET253.47' T/OPARAPET253.47' 1.50 O/H 5 S/G 1.00 O/H 241.60' T/OT/OPATIO242.67' PATIO242.67' 4 SKYLIGHT EX241.60' PR240.60' EX242.60' PR241.60' 4 S/G 4 S/G 6 S/G 5 S/G WATER CURTAIN STAIRLANDING STAIRLANDING SKYLIGHT S/G WATER CURTAIN TOC242.67' 2 S/G WATER CURTAIN (C)48.42 (F)48.17 620.196.9014.90 .19 3 125 4AA-BA MAINFLOOR (T.O CONC TOPP'G) EL 242.67' ROOFPEAK (T.O SHEATHING) EL 274.54' SECONDFLOOR (T.O CONC TOPP'G) EL 252.90' 12 .41' 1 .17' 8 .06' 1 .17' 9 .06' 1 .17' 3 .93' CRAWLSPACE (T.O CONC TOPP'G) EL 237.57' 6 .92 WINDOW HEADER 8 .00 WINDOW HEADER THIRDFLOOR (T.O CONC TOPP'G) EL 262.13' 33 .16 PR AVG BUILDING HEIGHT
LIMITINGDISTANCE: .20feet 1.28m BUILDINGFACEAREA: 1,058.15sq.ft 98.30sq.m OPENINGS %OFEXPOSINGBLDGFACEAREA MAX AGGREGATEAREAOFGLAZED 10.00% 105.81sq.ft 9.83sq.m [VBBL9.10.15.4.(8)] x2FORSPRINKLEREDBUILDING 14.53% 153.80sq.ft 14.29sq.m OPENINGS %OFEXPOSINGBLDGFACEAREA MAX AGGREGATEAREAOFGLAZED 7.27% 76.90sq.ft 7.14sq.m PROPOSEDOPENINGS: 14.46% 153.00sq.ft 14.21sq.m
LIMITINGDISTANCE: .20feet 1.28m BUILDINGFACEAREA: 941.00sq.ft 87.42sq.m [VBBL9.10.15.4.(7)] MAX OPENINGS(1.0mTO1.2mLIMITDIST.) 10% 94.10sq.ft 8.74sq.m OPENINGS %OFEXPOSINGBLDGFACEAREA MAX AGGREGATEAREAOFGLAZED 7.27% 68.38sq.ft 6.35sq.m [VBBL9.10.15.4.(8)] x2FORSPRINKLEREDBUILDING 14.53% 136.77sq.ft 12.71sq.m PROPOSEDOPENINGS: 12.22% 115.00sq.ft 10.68sq.m
1 CUSTOMPAINTEDHARDIESHINGLES-LACEDCORNERS 2 T&GHEMLOCKFINELINESIDING 3 ASPHALTROOF 4 'FINELINE'T&GSIDING&SOFFIT 4"EXPOSURE STAINED 5 2X10METALCLADFASCIAANDBARGEBOARDS 6 METALPANELWITH1/4"REVEALS 7 METALTRIMS CORNERBREAKSHAPES CAP&BASEFLASHING 8 HIGHPERFORMANCESLIDINGDOORS 9 VINYLWINDOWS 10 CLEARSTAINEDVGFIRFRONTDOOR MULTI-POINTHARDWARE 11 TRIPLEGLAZEDSKYLIGHTS 12 METALGRATERAILING FACEMOUNTEDWHEREPOSSIBLE 13 CONTINIOUSMINIMALGUTTERS 14 3"ROUNDMETALDOWNSPOUTS POWDERCOATED 15 CONCRETEWALLS PARGEANDPAINTASREQUIRED 16 CASTINPLACECONCRETESTAIRS SMOOTHFACEFINISH

TYPICALMATERIALSLEGEND-GARAGE

STRUCTURALENGINEERING:

GBSENGINEERINGGROUPLTD #14329HawkstreamDr

59FernwayDr, PortMoody BCV3H5K5 Phone:(604)362-7021

MYCORRHIZAURBANFORESTRY 1617783Ave Surrey BCV4N5T3 Phone:(778)222-6767

DOMUSHOMEENERGYINC 1556E5thAve#101 Vancouver BCV5N1L7 Phone:604-243-8616

239.5 238.3 237.8 238.5 239.2 239.1 238.4 237.8 239.0 238.1 237.6 239.4 240.5 240.9 241.0 239.9 32.99 TheBottomof Transformer's Elev is267.2 240.6 240.3 239.5 239.5 238.6 20'WIDELANE IRONIRONPOST POST POWER POLE 2.00 EV CHARGER EV CHARGER 37 ROOFABOVE ROOF ABOVE ROOF ABOVE ROOFABOVE 9 GARAGEDOOR MIN 2% SLOPE GARAGEP#1 STANDARDPARKING W/WALLONEACHSIDE (2.9M .5M) PR LOWSLAB EL 239.65' PR HIGHSLAB EL 239.95' PR LOWSLAB EL 239.65' MIN 2% SLOPE GARAGEP#2 STANDARDPARKING W/WALLONEACHSIDE (2.9M 5.5M) ROOFABOVE 9 GARAGEDOOR PR HIGHSLAB EL 239.95' GB G1 23.25 (F) G1 G2 23.38 (C) ASPHALTAPRON 6' WOOD FENCE 6' WOOD FENCE GUTTER GUTTER GUTTER GUTTER ASPHALTAPRON 6' WOOD FENCE CENTERLINEOFPAVEDLANE 239.50' 239.60' 239.50' 239.65' 239.55' 238.35' 238.45' 238.45' 238.60' SLOPE TO GUTTER SLOPE AWAY FROM PL SLOPE TO GUTTER 240.60' LAWN 240.60' CONC PAD 239.10' CONC PAD 239.10' G&R G&R G&R G&R G&R G&R NORTHPL EAST PL NORTHPL WEST PL A B C 21 .53 (C) GB GA 21 .40 (F) GA G1 DUPLEX RESIDENCE 3517 WEST 23RD AVENUE CONSTRUCTION: DESIGN: 216 289 ALEXANDER STREET VANCOUVER BC V6A 4H6 PHONE: (604) 677 7877 | ARCHITRIXSTUDIO .COM drawings design legal property Design and cannot be used or reproduced without written consent Contractors must verify all site conditions and confirm all dimensions Dimensions given scaled dimensions NOTES & VERSIONS: DRAWNBY: 3517W23RD STARTDATE:
GEOTECHNICALENGINEERING: ARBORIST: CEACONSULTANT: 2022 .09 .21_PRELIM FOR STRUCTURAL & CEA JOB#: SS KN MARCH2022 VANCOUVER B .C 2882W35thAve Vancouver BCV6N2M4 Phone:(604)603-5820
Surrey BC V3W0N5 Phone:(604)599-8890
BUILDINGDIMENSIONNOTE: GRIDLINEDIMENSIONSARETOFACEOFSHEATHING FACEOFCONCRETE ADD .5"TOEACHSIDEFORFACEOFCLADDINGDIMENSION (C)FORDIMENSIONSTOCLADDING (F)FORDIMENSIONSTOFOUNDATION ROUGHOPENINGSNOTE: ALLTHEEXERIOROPENINGSDIMENSIONNOTESAREROUGHOPENINGS ALLTHEINTERIORDOORSAREOFFSET3"FROMSTUD .N.OONDRAWINGS GARAGE: PLANS , ELEVATIONS & SECTIONS G1.0 EXTERIORGARAGEWALL-UNISULATED HZ5HARDIESHINGLE®CLADDING(ASPERCCMC12678-RREPORT) WRBBUILDINGWRAP(AB) LAPPED TAPEDSEAMSINCL TAPETOTOPOFFOUNDATION&TOPOFWALLSHEATHING 1/2"EXT PLYWOODorOSBSHEATHING 2X4 .D WOODSTUDS@16"O.C FRAMING(REF STRUCT.) 1/2"GWB PAINTED GARAGEFLOORSLAB-UNINSULATED FINISHEDFLOORINGW/SPEC UNDERLAYorPOLISHEDCONCRETE 4"RE-INFORCEDCONCRETESLAB(SEESTRUCT 6MILPOLYVAPOURBARRIERON 6"DRAINGRAVEL COMPACTSTRUCTURALFILL G-F1 G-W2 MAINROOF UNINSULATED 45MINFIRE-RATED ASPHALTROOFINGON ROOFINGFELTW/LAPPED STAGGEREDSEAMS; EAVEPROTECTIONPROVIDED12"BEYONDINSIDEFACEOFEXT WALL 5/8"PLYWOODSHEATHING(P.T orBORATE-TREATED) ENG'DTRUSSES@24"O.C (REF STRUCT INTERIORCONDITION 5/8"TYPE'X'GWB PAINTED SOFFITCONDITION (optional)1XWOODSTRIPSFURRINGFORSOFFITINSTALL 3/4"T&GSTAINED&SEALEDWOODSOFFITS G-R1 ASSEMBLYLEGEND DETACHEDGARAGE FOUNDATIONWALL UNINSULATED SANDORPARGEDCONCRETEIFREQUIRED(ABOVE-GRADE) DRAINAGEMAT&BITUM DAMPPROOFINGMEMBRANE(BELOW-GRADE) 8"REINFORCEDCONC WALL(REF STRUCT.) G-W1 INTERIORWALL-UNISULATED 45MIN FIRE-RATED [REFERA-9.10.3.1.A] 5/8"TYPE-XGWB PAINTED 2X4OR2X6STUDS(REF STRUCTURAL)@16"O.C 5/8"TYPE-XGWB PAINTED G-W3 12 4 G-R1 G-F1 G-W3G-W2 G-W1 GARAGEP#1 GARAGEP#2 SECTIONGA SCALE:1/4" 1'-0 8 .00 T/O FOUNDATION TO T/O STUD 2 .13 EQUAL 2 .13 EQUAL 1.00 O/H .00 O/H 11 .17 PR MEAN BUILDING HEIGHT 13 .31 PR AVG BUILDING HEIGHT 239.70' 239.70' SG239.50'@PL MAXEL254.59' HT4.6M MAXEL251.64' HT3.7M PL PL SG238.60'@PL EL253.69'MAXHT4.6M EL250.74'MAXHT3.7M T/OFOUNDATIONWALL EL 240.40' T/OTOPPLATE EL 248.40' 4 .60 8 .00 .45 .30 GARAGESLAB-LOW EL 239.65' ROOFPEAK EL 253.065' GARAGESLAB-HIGH EL 239.95' GB G1 (F)23.25 G1 G2 (C)23.38 ROOFPLAN SCALE:1/4"=1'-0" GARAGEMAINFLOORPLAN SCALE:1/4"=1'-0" 7 .00 HDR G-R1 HIGHSLAB239.95' G-W2 G-F1 G-W1 LOWSLAB 239.65' GARAGEP#1 SECTIONGB SCALE:1/4"=1'-0 239.55' 239.50' 239.70' .00 O/H 1.00 O/H T/OFOUNDATIONWALL EL 240.40' T/OTOPPLATE EL 248.40' 4 .60 8 .00 .45 .30 GARAGESLAB-LOW EL 239.65' ROOFPEAK EL 253.065' GARAGESLAB-HIGH EL 239.95' 21.53 (C) GAGB 21.40 (F) G1GA PL .O.C 240.40' 8-EX240.00' PR239.40' 7-EX239.40' PR239.40' 12 4 SOUTHELEVATION SCALE:1/4"=1'0 2 .13 C .L 2 .13 C .L 5 6 2 7 9 SG239.50'@PL MAXEL254.59' HT4.6M MAXEL251.64' HT3.7M PL PL SG238.60'@PL EL253.69'MAXHT4.6M EL250.74'MAXHT3.7M T/OFOUNDATIONWALL EL 240.40' T/OTOPPLATE EL 248.40' 4 .60 8 .00 .45 .30 GARAGESLAB-LOW EL 239.65' ROOFPEAK EL 253.065' GARAGESLAB-HIGH EL 239.95' GB G1 (F)23.25 G1 G2 (C)23.38 DOORSILL@ SLABHIGH TOC239.65' .O.C 240.40' EASTELEVATION SCALE:1/4"=1'0 7 .00 HDR .53 DOOR SILL TO GRADE 3 6 .25 DOOR HDR TO T/O FOUNDATION 1.00 O/H .00 O/H 7-EX239.40' PR239.40' 6-EX239.40' PR239.40' 1 4 32 7 9 5 T/OFOUNDATIONWALL EL 240.40' T/OTOPPLATE EL 248.40' 4 .60 8 .00 .45 .30 GARAGESLAB-LOW EL 239.65' ROOFPEAK EL 253.065' GARAGESLAB-HIGH EL 239.95' 21.53 (C) GAGB 21.40 (F) G1GA PL T .O .C 240 .40' DOORSILL@ SLABLOW TOC239.65' 7 .00 HDR 5-EX239.40' PR239.40' 9 OVERHEAD DOORS 12 NORTHELEVATION SCALE:1/4"=1'0 OVERHEAD DOORS 6-EX239.40' PR239.40' 6 102 10 SG239.50'@PL EL254.59' MAXHT4.6M EL251.64' MAXHT3.7M PLPL SG238.60'@PL MAXEL253.69' HT4.6M MAXEL250.74' HT3.7M T/OFOUNDATIONWALL EL 240.40' T/OTOPPLATE EL 248.40' 4 .60 8 .00 .45 .30 GARAGESLAB-LOW EL 239.65' ROOFPEAK EL 253.065' GARAGESLAB-HIGH EL 239.95' G1GB 23.25 (F) G2G1 23.38 (C) DOORSILL@ SLABHIGH TOC239.65' .O.C 240.40' WESTELEVATION SCALE:1/4"=1'0 7 .00 HDR .53 DOOR SILL TO GRADE 3 6 .25 DOOR HDR TO T/O FOUNDATION .00 O/H 1.00 O/H 5-EX239.40' PR239.40' 8-EX240.00' PR239.40' 1 4 2 3 7 9 5 (C)21.53 GB GA (F)21.40 GA G1 T/OFOUNDATIONWALL EL 240.40' T/OTOPPLATE EL 248.40' 4 .60 8 .00 .45 .30 GARAGESLAB-LOW EL 239.65' ROOFPEAK EL 253.065' GARAGESLAB-HIGH EL 239.95' PL
1 ASPHALTROOFING 2 HEMLOCK 'FINELINE'T&GSIDING&SOFFIT STAINED 3 METALSIDEDOORSorEQUIV 4 5"CONTINUOUSMINIMALGUTTERS 5 3"ROUNDMETALDOWNSPOUTS POWDERCOATED 6 2XWOODBARGEBOARDS METALWRAPPED 7 EXPOSEDCONCRETEWALLS PARGEANDPAINTASREQUIRED 9 METALTRIMS,CORNERBREAKSHAPES CAP&BASEFLASHING 10 GARAGEOVERHEADDOOR-PAINTEDorPRE-FINISHED ASPHALTSHINGLE SLOPE4:12 253.065' LINE OF SHEATHING BELOW LINE OF SHEATHING BELOW ROOFPEAK ASPHALTSHINGLE SLOPE4:12 1.00 O/H 1 .00 O/H 1.00 O/H 1 .00 O/H 1.00 O/H 1 .00 O/H 1.00 O/H 1 .00 O/H NORTHPL EAST PL NORTHPL WEST PL 21 .53 (C) GB GA 21 .40 (F) GA G1

FIRSTFLOOR SCALE:1/4"=1'-0"

TOTALFLOORAREA

THERMALEXCLUSION

FRONTUNITCOV

UNIT-AREACOUNT

UNIT1(FRONTUNIT)

MAINFLOOR 521.4sq.ft

SECONDFLOOR 521.4sq.ft

HALFFLOOR 370.8sq.ft

THERMALEXCLUSION(2%) -28.3sq.ft

LOWSLOPECEILING(EXCLUDED) -104.1sq.ft

TOTALAREAUNIT1 1,281.2sq.ft

UNIT2(REARUNIT)

MAINFLOOR 668.9sq.ft

SECONDFLOOR 668.9sq.ft

HALFFLOOR 369.1sq.ft

THERMALEXCLUSION(2%) -34.1sq.ft

LOWSLOPECEILING(EXCLUDED) -103.2sq.ft

TOTALAREAUNIT2 1,569.5sq.ft

GBSENGINEERINGGROUPLTD #14329HawkstreamDr

SECONDFLOOR

59FernwayDr, PortMoody BCV3H5K5 Phone:(604)362-7021

MYCORRHIZAURBANFORESTRY 1617783Ave Surrey BCV4N5T3 Phone:(778)222-6767

DOMUSHOMEENERGYINC 1556E5thAve#101 Vancouver BCV5N1L7 Phone:604-243-8616

THIRDFLOOR

DUPLEX RESIDENCE 3517 WEST 23RD AVENUE CONSTRUCTION: DESIGN: 216 289 ALEXANDER STREET VANCOUVER BC V6A 4H6 PHONE: (604) 677 7877 | ARCHITRIXSTUDIO .COM drawings design legal property Design and cannot be used or reproduced without written consent Contractors must verify all site conditions and confirm all dimensions Dimensions given scaled dimensions NOTES & VERSIONS: DRAWNBY: 3517W23RD STARTDATE: STRUCTURALENGINEERING: GEOTECHNICALENGINEERING: ARBORIST: CEACONSULTANT: 2022 .09 .21_PRELIM FOR STRUCTURAL & CEA JOB#: SS KN MARCH2022 VANCOUVER B .C 2882W35thAve Vancouver BCV6N2M4 Phone:(604)603-5820
Surrey BC V3W0N5 Phone:(604)599-8890
BUILDINGDIMENSIONNOTE: GRIDLINEDIMENSIONSARETOFACEOFSHEATHING FACEOFCONCRETE ADD .5"TOEACHSIDEFORFACEOFCLADDINGDIMENSION (C)FORDIMENSIONSTOCLADDING (F)FORDIMENSIONSTOFOUNDATION ROUGHOPENINGSNOTE: ALLTHEEXERIOROPENINGSDIMENSIONNOTESAREROUGHOPENINGS ALLTHEINTERIORDOORSAREOFFSET3"FROMSTUD .N.OONDRAWINGS AREA OVERLAYLWH OL1.0
1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR E/R E/R
1,190.23sq.ft
23.80sq.ft COUNTEDFLOORAREA 1,166.42sq.ft
PORCH 34.88sq.ft REARUNITCOV PORCH 34.88sq.ft BAYWINDOW 7.60sq.ft CEILINGHEIGHT 9.060 FRONTUNITAREA(GROSS) 521.36sq.ft REARUNITAREA(GROSS) 668.86sq.ft CRAWLSPACE SCALE:1/4"=1'-0" CRAWLSPACE 1,190.23sq.ft COUNTEDFLOORAREA 0.00sq.ft CEILINGHEIGHT 3.937
SCALE:1/4"=1'-0" TOTALFLOORAREA 1,190.23sq.ft THERMALEXCLUSION 23.80sq.ft COUNTEDFLOORAREA 1,166.42sq.ft CEILINGHEIGHT FRONTUNITAREA(GROSS) 521.37sq.ft REARUNITAREA(GROSS) 668.86sq.ft 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR UNIT1 MAIN FLOOR 165.93' 165.93' UNIT2 MAIN FLOOR 21 .21 24.58 21 .21 27 .21 24.58 27 .21 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 13 .52 7 .69 7 .69 13 .41 6 .11 .97 6.73 3.97 6 .57 14 .52 6 .11 13 .52 7 .69 4.83 .97 6.73 3.97 4.83 LOW CEILING EXCLUSION LOW CEILING EXCLUSION LOW CEILING EXCLUSION LOW CEILING EXCLUSION COVERED DECK 14.42 13 .11 13 .11 14.42 14.67 13 .00 11 .15 UNIT1 THIRDFLOOR 175.16' 175.16' UNIT2 THIRDFLOOR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR UNIT1 MAINFLOOR 155.70' UNIT2 MAINFLOOR 155.70' 24.58 1.00 1 .56 8 .25 11 .40 5 .91 21 .21 24.58 1.00 17 .40 8 .25 1 .56 5 .91 27 .21 .91 .91 COVERED PORCH COVERED PORCH 3 .00 36" .00 36" DRAIN 3 .00 36" .00 36" DRAIN NONLOAD BEARINGWALLFOR FUTUREACCESS NONLOAD BEARINGWALLFOR FUTUREACCESS
SCALE 1/4"=1'-0" GROSSFLOORAREA 707.3sq.ft THERMALEXCLUSION 14.1sq.ft AREABETWEEN1.2M-2.3MEXCLUSION 207.3sq.ft COUNTEDFLOOR 485.9sq.ft COVEREDPORCH(DECK 88.6sq.ft CEILINGHEIGHT SLOPEDCEILING UNIT1AREA 370.8sq.ft UNIT2AREA 369.1sq.ft
DRAWING NUMBERING IS BASED ON A CHAPTER SYSTEM FOLLOWING THIS FORMAT: A4.2 A DISCIPLINE PREFIX 4 CHAPTER GROUP NUMBER .2 DRAWING NUMBER DISCIPLINE INDEX A. ARCHITECTURAL C. CIVIL E. ELECTRICAL K. FOOD SERVICE M. MECHANICAL S. STRUCTURAL T. TRANSPORTATION ARCHITECTURAL CHAPTER INDEX A000 FRONT END DOCUMENTS (COVER PAGE, GENERAL INFORMATION, SCHEDULES) A100 SITE PLANS, SITE DETAILS A200 FLOOR PLANS, ROOF PLANS A300 REFLECTED CEILING PLANS A400 EXTERIOR ELEVATIONS A500 BUILDING SECTIONS, WALL SECTIONS A600 VERTICAL CIRCULATION, PLANS AND SECTIONS A700 PLAN DETAILS, SECTION DETAILS A800 INTERIOR ELEVATIONS, MILLWORK DETAILS A900 FINISHES A1000 VISUALIZATION DRAWING BINDING SEQUENCE IN THE PROPERTIES OF EACH SHEET THERE IS A PARAMETER NAMED "SHEET LIST GROUPING" USED TO SORT THE SHEETS FOR THE "LIST OF DRAWINGS". INPUT A NUMBER ACCORDING TO THE LIST BELOW. 1 ARCHITECTURAL (A000 SERIES) 2 CIVIL 3 ARCHITECTURAL (A100 THROUGH A1200 SERIES) 4 FOOD SERVICE 5 STRUCTURAL 6 MECHANICAL 7 ELECTRICAL 8 TRANSPORTATION PROJECT BROWSER ORGANIZATION DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION ZONING MATRIX BDC1 LOT FRONTAGE EXTERIOR SIDE & FRONT YARD DEPTH INTERIOR SIDE & REAR YARD DEPTH LOT COVERAGE MAX. LANDSCAPE OPEN SPACE MIN. PARKING REQUIRED 6.0m MIN. 6.0m MIN. 6.0m MIN. 45% MIN. 30% MIN. RESIDENTIAL -1/UNIT RESTAURANT -1/15 m FOOD STORE -1/25 m TAVERN -1/6 m OFFICE -1/40 m PROVIDED 3.0m MIN. 3.0m MIN. 1.0m MIN. 35% MIN. 30% MIN. RESIDENTIAL -1/UNIT RESTAURANT -1/15 m FOOD STORE -1/25 m TAVERN -1/6 m OFFICE -1/40 m DRAWINGFILE CHECKED DATE DRAWING TITLE REVISION PROJECT TITLE DRAWN DATE NO.REVISION BY REVISIONS KEY-PLAN: School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: ONTARIO BUILDING CODE DATA MATRIX PARTS 3 AND 9 1 OBC Reference Project Description: Part 11New Addition AlterationChange of Use Part 3Part 2.1.1 9.10.1.3 2 Major Occupancy(s): OCCUPANCY A, DIVISION / OCCUPANCY D, E AND C 9.10.23.1.2.1.(1) 3 4 5 6 7 Building Area (m2): Gross Area: Number of Storeys: Height of Building: 7-STOREYS Number of Streets/Access Route(s): 2 STREETS, 2 ACCESS ROUTES Existing: 0.00 New: 2717.15 m2 Total: 2717.15 m 1.1.3.21.1.3.2 1.1.3.21.1.3.2Existing: 0.00 New: 9991.83 m2 Total: 9991.83 m Above Grade: Below Grade: 0 3.2.1.1 1.1.3.22.1.1.3 2.1.1.3 3.2.2.10 & 3.2.5.5 Building Classification: GROUP A DIV 2, ANY HEIGHT, SPRINKLERED, NON-COMBUSTIBLE CONST. Sprinkler System Proposed: 8 9 3.2.2.20 -83 9.10.4 Entire Building In Lieu of Roof Rating Basement Only Not Required 3.2.2.20 -83 9.10.4 3.2.1.5 3.2.2.17 10 Standpipe Required: NoYes 11 Fire Alarm Required: NoYes 12 Water Service Adequate Supply: NoYes 13 High Building: NoYes 14 Permitted Construction: Non-combustibleCombustible Actual Construction: Non-combustibleCombustible 3.2.9 3.2.4 3.2.6 3.2.2.20 -83 9.10.7.2 9.10.6 16 Occupant Load Based On: Design of Buildingm2 person 1st Floor: 3/4/5th Floor: Occupancy: GROUP A2 Occupancy: GROUP D Occupancy: GROUP E Occupancy: GROUP C Occupancy: GROUP C Load: 300 PERSONS (REFER NOTE 1) Load: 54 PERSONS Load: 82 PERSONS Load: 08 PERSONS (REFER NOTE 2) Load: 120 PERSONS 15 Mezzanine Area (m2): 17 Barrier Free: No (Explain):Yes 3.8 3.2.1.1.(3)-(8) 3.1.1.6 9.10.4.1 9.9.1.3 18 Hazardous Substances: No (Explain): OCCUPANCYYes 3.3.1.2(1) 3.3.1.19.(1) 9.5.2 9.10.1.3 19 Horizontal Assemblies (FRR -Hours) Listed Design No. or Description (SG-2) Floor(s): 2 Hours Roof: 0 Hours Mezzanine(s): 1 Hour FRR Supporting Member(s)Listed Design No. or Description (SG-2) Floor(s): 2 Hours Roof: 0 Hours Mezzanine(s): 1 Hour Required Fire Resistance Rating (FRR) 3.2.2.20 -83 3.2.1.4 9.10.8 9.10.9 Consultant: Architecture Consultant: Structural Engineering PROJECT TEAM Consultant: Construction Management Consultant: Building Services Consultant: Civil Engineering Consultant: Landscape Architecture O.B.C SB-2 / O.B.C SB-3 O.B.C SB-2 / O.B.C SB-3 O.B.C SB-2 / O.B.C SBO.B.C SB-2 / O.B.C SB-3 6th-7th Floor: 3/4/5th Floor:Occupancy: GROUP C Load: 36 PERSONS 1. 2. OCCUPANCIES OF GROUP A DIVISION ARE AS PER DESIGN OF SUITE AS PER O.B.C 3.1.17.1.(6) OCCUPANCIES OF GROUP C ARE BASED ON 2 PERSONS PER SLEEPING ROOM SLEEPING AREA IN A DWELLING UNIT OR SUITE AS PER O.B.C 3.1.17.1.(1).(b) ALL WALLS TO HAVE UNLIMITED AMOUNT OF UMPROTECTED OPENINGS. EXTERIOR WALL CLADDING TO BE OF NONCOMBUSTIBLE MATERIAL. EXTERIOR WALLS ARE NOT REQUIRED TO HAVE A FIRE RESISTANCE RATING. ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 PN TN A000 COVER SHEET AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS SKYSCAPE CONDOS 90% DESIGN DEVELOPMENT

3.2.4.18

ONTARIO BUILDING CODE NOTES

BUILDING

18. OBC

ALL

19. OBC 9.33.4.2. -LOCATION OF CARBON

CARBON MONOXIDE

20. OBC 3.8.1.3.

OF TRAVEL SHALL: BE BEVELED

(3) IF BARRIER FREE PATH OF

SPACE SHALL BE

21.OBC 3.8.3.3.

AND

MANUAL

SITE PLAN SYMBOL LEGEND

PROPERTY

ZONING MATRIX

COMMERCIAL

EMERGENCY SERVICE EXITS

BARRIER FREE PARKING

FIRE ROUTE ACCESS CENTRE LINE

REFUSE TRUCK

BUILDING PLAN

SITE PLAN LANSCAPE LEGEND

FHC DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION ONTARIO BUILDING CODE NOTES NOTES: 1. OBC 3.1.3.1. -SEPARATION OF MAJOR OCCUPANCIES: OCCUPANCY C -OCCUPANCY A-2: 1H FIRE RESISTANCE RATING OCCUPANCY A-2 -OCCUPANCY D: 1H FIRE RESISTANCE RATING OCCUPANCY C -OCCUPANCY E: 2H FIRE RESISTANCE RATING OBC 3.3.4.2. -RESIDENTIAL OCCUPANCY -FIRE SEPARATIONS SUITES OF A RESIDENTIAL OCCUPANCY TO BE SEPARATED FROM EACH OTHER AND THE REMAINDER OF THE BUILDING BY A FIRE SEPARATION HAVING A FIRE RESISTANCE RATING NOT LESS THAN 1H. 2. OBC 3.1.9. -PENETRATIONS IN FIRE SEPARATIONS AND FIRE-RATED ASSEMBLIES PENETRATIONS OF A FIRE SEPARATION OR A MEMBRANE FORMING PART OF AN ASSEMBLY REQUIRED TO HAVE A FIRE RESISTANCE RATING SHALL BE SEALED WITH FIRE STOPS TESTED IN ACCORDANCE WITH CAN/ULC-S115. 3. OBC 3.2.4.9. -ANNUNCIATOR AND ZONE INDICATION ANNUNCIATOR SHALL BE INSTALLED IN CLOSE PROXIMITY TO A BUILDING ENTRANCE THAT FACES A STREET OR AN ACCESS ROUTE FOR FIRE DEPARTMENT VEHICLES. SHAFTS REQUIRED TO BE EQUIPPED WITH FIRE DETECTOR CONNECTED TO ANNUNCIATOR ZONE. 4. OBC 3.2.4.11 -FIRE DETECTORS FIRE DETECTORS SHALL BE INSTALLED IN EACH: -STORAGE ROOMS NOT WITHIN A DWELLING UNIT. -SERVICE ROOMS NOT WITHIN A DWELLING UNIT. -JANITORS ROOM. -ROOMS IN WHICH HAZARDOUS SUBSTANCES TO BE USED OR STORED. -LAUNDRY ROOMS NOT WITHIN A DWELLING UNIT. -HAZARDOUS CLASSROOMS. 5. OBC 3.2.4.12. -SMOKE AND HEAT DETECTORS SMOKE DETECTORS TO BE INSTALLED IN EACH: -CONTAINED USE AREA AND CORRIDORS SERVING THOSE ROOMS. -PUBLIC CORRIDORS CLASSIFIED AS GROUP C MAJOR OCCUPANCY. -EXIT STAIR SHAFT. -ELEVATOR MACHINE ROOM OR MACHINERY SPACE. -NEAR ENTRANCE TO A VESTIBULE. 6. OBC 3.4.5.1. -EXIT SIGNAGE EVERY EXIT DOOR SHALL HAVE AN EXIT SIGN PLACED OVER OR ADJACENT TO IT IF THE EXIT SERVES, -BUILDING MORE THAN 2-STOREYS IN HEIGHT. -BUILDING HAVING AN OCCUPANT LOAD MORE THAN 150. -ROOM OR FLOOR AREA THAT HAS A FIRE ESCAPE AS PART OF A REQUIRED MEANS OF EGRESS. EXIT SIGN TO BE CONTINUOUSLY LUMINATED AND BE OF A "RUNNING MAN" SYMBOL -REFER TO LATEST EDITION OF THE ONTARIO ELECTRICAL CODE. 7. OBC 3.2.7.3. -EMERGENCY LIGHTING EMERGENCY LIGHTING SHALL BE PROVIDED TO AN AVERAGE LEVEL OF ILLUMINATION NOT LESS THAN 10 lx AT FLOOR OR TREAD LEVEL IN: -EXITS -PRINCIPAL ROUTES PROVIDING ACCESS TO EXIT IN AN OPEN FLOOR AREA AND IN SERVICE ROOMS. -PUBLIC CORRIDORS -FLOOR AREAS IN GROUP DIVISION 2 OCCUPANCIES WITH OCCUPANT LOAD OF MORE THAN 60. 8. OBC 3.2.9.4. -HOSE STATIONS PROVIDE HOSE STATIONS IN EACH STOREY IN THE BUILDING: -TO CONTAIN LISTED FIRE EXTINGUISHER -REACH EVERY PORTION OF THE BUILDING FLOOR AREA WITH A HOSE STREAM NO GREATER THAN 3m CONFIRM SIZE, QUANTITY AND LOCATION WITH CONSULTANTS. 9. OBC 3.4.4.1. -FIRE RESISTANCE RATING OF EXIT SEPARATIONS EXIT SHALL BE SEPARATED FROM THE REMAINDER OF THE BUILDING BY A FIRE SEPARATION HAVING A FIRE RESISTANCE RATING NOT LESS THAN THAT REQUIRED IN SUBSECTION 3.2.2., BUT NOT LESS THAN 45min., FOR: -FLOOR ASSEMBLY ABOVE THE STOREY -FLOOR ASSEMBLY BELOW THE STOREY 10. OBC 3.8.1.5. -CONTROLS FOR POWER DOOR OPERATOR CONTROLS, CONTROLS FOR OPERATION OF BUILDING SERVICES OR SAFETY DEVICES, INCLUDING ELECTRICAL SWITCHES, THERMOSTATS AND INTERCOM SWITCHES, INTENDED TO BE OPERATED BY THE OCCUPANT AND LOCATED IN BARRIER FREE PATH OF TRAVEL: -ACCESSIBLE FROM PERSON IN WHEELCHAIR FROM SIDE APPROACH -OPERATED USING ONE HAND WITH MAX. FORCE OF 22.2N -LOCATED BETWEEN 900 AND 1100 OFF OF FINISHED FLOOR LEVEL 11. OBC
-MANUAL PULL STATIONS A
PULL STATION SHALL BE INSTALLED: -NEAR THE PRINCIPLE ENTRANCE TO THE BUILDING -NEAR EVERY REQUIRED EXIT 12. OBC 3.8.3.2. -EXTERIOR WALKS EXTERIOR WALKS THAT FORM A BARRIER FREE PATH OF TRAVEL SHALL -PROVIDE MEANS OF CONTINUOUS PLANE NOT INTERRUPTED BY STAIRS OR ABRUPT CHANGE IN LEVEL -HAVE A TACTILE ATTENTION INDICATOR THAT IS LOCATED TO IDENTIFY AN ENTRY INTO VEHICULAR ROUTE OR AREA WHERE NO CURBS OR ANY OTHER ELEMENT SEPARATE THE VEHICULAR ROUTE OR AREA FROM A PEDESTRIAN ROUTE. 13. OBC 3.2.5.6. -ACCESS ROUTE DESIGN A PORTION OF ROADWAY OR YARD PROVIDED AS A REQUIRED ACCESS ROUTE FOR FIRE DEPARTMENT SHALL: -CLEAR WIDTH OF 6.0m -CENTERLINE RADIUS OF 12.0m -BE CONNECTED WITH A PUBLIC THOROUGHFARE 14. OBC 3.8.3.18. -TACTILE ATTENTION INDICATORS THE DEPTH OF THE TACTILE ATTENTION INDICATOR SHALL NOT BE LESS THAN 300mm AND NOT MORE THAN 610mm. 15. OBC 9.8.8.3 -HEIGHT OF GUARDS ALL GUARDS SHALL BE A MINIMUM OF 1070mm HIGH. 16. OBC 9.10.19.1. -REQUIRED SMOKE ALARMS SMOKE ALARMS SHALL BE INSTALLED IN EACH DWELLING UNIT AND IN EACH SLEEPING ROOM NOT WITHIN A DWELLING UNIT. SMOKE ALARMS SHALL HAVE A VISUAL SIGNALING COMPONENT AS WELL AS AUDIBLE COMPONENT CONFORMING TO NFPA 72 "NATIONAL ALARM AND SIGNALING CODE".
(CONT...) NOTES: 17. OBC 9.10.19.3 -LOCATION OF SMOKE ALARMS SMOKE ALARMS WITHIN A DWELLING UNIT SHALL BE INSTALLED IN: -EACH STOREY, INCLUDING BASEMENTS -EACH SLEEPING ROOM -IN A LOCATION BETWEEN SLEEPING ROOMS AND THE REMAINDER OF THE STOREY.
9.10.19.5. -INTERCONNECTION OF SMOKE ALARMS SMOKE ALARMS SHALL BE CONNECTED SO THAT THE ACTIVATION OF ONE ALARMS CAUSES
ALARMS IN THE UNIT TO SOUND.
MONOXIDE ALARMS
ALARMS SHALL BE LOCATED ADJACENT TO SLEEPING ROOMS WITHIN A DWELLING UNIT.
-BARRIER FREE PATH OF TRAVEL (1) EVERY BARRIER FREE PATH OF TRAVEL SHALL PROVIDE AN UNOBSTRUCTED WIDTH OF 1100mm FOR PASSAGE OF WHEEL CHAIRS. (2) INTERIOR AND EXTERIOR WALKING SURFACES THAT ARE WITHIN BARRIER FREE PATH
AT MAXIMUM SLOPE OF IN AT CHANGES IN LEVEL NOT MORE THAN 13mm.
TRAVEL IS LESS THAN 1600mm, AN 1800mm 1800mm TURNING
PROVIDED NOT MORE THAN 30m APART FROM EACH OTHER.
-DOORWAYS
DOORS EVERY DOORWAY THAT IS LOCATED IN A BARRIER FREE PATH OF TRAVEL SHALL HAVE A CLEAR WIDTH OF NOT LESS THAN 860mm WHEN THE DOOR IS IN OPEN POSITION DOOR OPENING DEVICES THAT ARE THE ONLY MEANS OF OPERATION SHALL: -BE OPERABLE USING A CLOSED FIST -BE MOUNTED NOT LESS THAN 900mm AND NOT MORE THAN 1100mm ABOVE FINISHED FLOOR UNLESS EQUIPPED WITH A DOOR OPERATOR, A DOOR IN A BARRIER FREE PATH OF TRAVEL SHALL HAVE A CLEAR WIDTH ON THE LATCH SIDE OF THE DOOR, EXTENDING THE HEIGHT OF THE DOOR AND NOT LESS THAN: -600mm BEYOND EDGE OF DOOR OPENING IF THE DOOR SWINGS TOWARDS THE APPROACH SIDE. -300mm BEYOND EDGE OF THE DOOR IF THE DOOR SWINGS AWAY FROM THE APPROACH SIDE. -300mm BEYOND EDGE ON BOTH SIDES IF SLIDING DOOR. 22. OBC 3.8.3.3.(11) -VESTIBULES IN BARRIER FREE PATH OF TRAVEL WHERE DOORS ARE IN SERIES, 1500mm (MINIMUM) SHALL BE PROVIDED BETWEEN DOORS PLUS THE SWING OF THE DOOR. 23. OBC 9.8.8.1. -REQUIRED GUARDS (5) -OPERABLE WINDOWS IN BUILDINGS OF RESIDENTIAL OCCUPANCY SHALL BE PROTECTED BY A: -A GUARD CONFORMING TO THIS SUBSECTION -A MECHANISM CAPABLE OF CONTROLLING THE FREE SWINGING OR SLIDING OF THE OPERABLE PART OF THE WINDOW SO AS TO LIMIT ANY CLEAR UNOBSTRUCTED OPENING TO A SIZE THAT WILL PREVENT THE PASSAGE OF A SPHERE HAVING A DIAMETER NOT LESS THAN 100mm. 24. OBC 3.8.3.12. -UNIVERSAL WASHROOMS UNIVERSAL WASHROOMS SHALL CONFORM TO THIS SUBSECTION. 25. OBC 3.2.5.3. -ROOF ACCESS BUILDING MORE THAN 3-STOREYS IN BUILDING HEIGHT WHERE THE ROOF SLOPE IS LESS THAN 1 IN 4, ALL MAIN ROOF AREAS SHALL BE PROVIDED WITH DIRECT ACCESS FROM FLOOR AREAS IMMEDIATELY BELOW, EITHER BY, -A STAIRWAY -A HATCH NOT LESS THAN 550mm x 900mm WITH A FIXED LATER DRAWING SYMBOLS LEGEND OFFICE 1002 1t 1300 1 A00.0 SIM A101 1 SIM A101 SIM 1 SIM SIM 1 SIM Ref 1 A00.0 ROOM IDENTIFIER ROOM NAME ROOM NUMBER BUILDING SECTION DETAIL NUMBER SHEET NUMBER REFERENCE 1 A00.0 SIM WALL SECTION DETAIL NUMBER SHEET NUMBER REFERENCE BUILDING ELEVATION REFERENCE SHEET NUMBER DETAIL NUMBER INTERIOR ELEVATION REFERENCE SHEET NUMBER DETAIL NUMBER ENLARGED PLAN DETAIL DETAIL NUMBER SHEET NUMBER REFERENCE DETAIL EXTENT CEILING IDENTIFIER CEILING HEIGHT CEILING TYPE ASSEMBLY IDENTIFIERS W2 W2 WALL PARTITION TYPE FLOOR TYPE ROOF TYPE F2 R2 CURTAINWALL TYPE OPENING IDENTIFIER D.01.100.01 W1 DOOR NUMBER WINDOW NUMBER (EXTERIOR) SUITE NUMBER LEVEL NUMBER GENERAL NOTES 1. DRAWINGS ARE NOT TO BE SCALED. 2. ALL DIMENSIONS AND INSTALLATIONS ARE TO BE VERIFIED ON SITE. 3. CONTRACTOR TO COMPLY TO ALBERTA BUILDING CODE (ABC) 2006 IN ADDITION TO ANY AND ALL AUTHORITIES HAVING JURISDICTION DURING ALL PHASES OF WORK. 4. IT IS THE CONTRACTOR'S RESPONSIBILITY TO BRING ALL OMISSIONS, DISCREPANCIES, INCLUDING DIMENSIONS, TO THE ATTENTION OF THE ARCHITECT PRIOR TO THE COMMENCING OF ANY WORK. 5. ANY PATCHING, REPAIR, REFINISHING, RECONSTRUCTION AND REPAINTING WORK REQUIRED AS A RESULT OF PERFORMANCE OF WORK UNDER THIS CONTRACT SHALL BE PERFORMED WITH MATERIALS TO MATCH EXISTING AND SHALL MAINTAIN REQUIRED FIRE RATINGS. 6. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT WHEREVER A FIRE SEPARATION IS REQUIRED AS INDICATED BY THE CONSTRUCTION DRAWINGS, ALL COMPONENTS OF THE ASSEMBLY ARE TO BE APPROVED MATERIALS WITHIN THE INSTALLATION/FABRICATION PROCEDURES PER DIRECTIONS OF THE U.L.C. NUMBER AND/OR REQUIREMENTS OF THE ABC 2006. ALL FIRE SEPARATIONS MUST BE CONTINUOUS WITHIN THEIR EXTENT, AND ALL JOINTS TO BE AIR TIGHT. 7. DIMENSIONS INDICATED ON FLOOR PLANS ARE TO GRID LINE, EXTERIOR FACE OF SHEATHING FOR EXTERIOR WALLS, OR CENTERLINE OF INTERIOR PARTITIONS. SEE FLOOR PLANS FOR ADDITIONAL DIMENSION NOTES. 8. WHERE TYPE "X" GYPSUM BOARD IS NOTED ON DRAWINGS, PROVIDE FIRE-RESISTANT GYPSUM BOARD C/W U.L.C. LABEL. 9. WHEN A PARTITION OCCURS ALONG A CONTROL JOINT, FASTEN THE TRACK TO ONE SIDE ONLY. 10. GYPSUM BOARD CONTROL JOINTS ARE TO BE AT 9000mm O.C. MAXIMUM, OR AS OTHERWISE SPECIFIED OR SHOWN. 11. PROVIDE 19mm PLYWOOD BACKING AT TELEPHONE AND SURFACE MOUNTED ELECTRICAL PANEL LOCATIONS. PAINT PRIOR TO INSTALLATION WITH FIRE-RETARDANT PAINT. 12. PROVIDE SHEET STEEL BACKING IN STUD PARTITIONS BEHIND GYPSUM BOARD AT ALL RECESSED OR SURFACE MOUNTED EQUIPMENT, MILLWORK, AND ACCESSORIES AT ALL ANCHOR POINTS. BACKING TO BE 18ga. GALVANIZED METAL IN 300mm WIDE STRIPS FASTENED TO 3 STUDS MINIMUM. 13.IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE HIS OWN FORCES AND HIS SUB TRADES TO ENSURE THAT HOLES CUT FOR PENETRATIONS THROUGH THE EXTERIOR WALL SYSTEMS ARE NOT OVERSIZED. AFTER INSTALLATION OF ANY PENETRATIONS, THE VOIDS BETWEEN THE PENETRATION OPENING AND THE PENETRATED MATERIALS SHALL BE COMPLETELY SEALED TO ENSURE THE INTEGRITY OF THE AIR/VAPOUR BARRIER. 14.SEAL ALL ARCHITECTURAL, STRUCTURAL, MECHANICAL OR ELECTRICAL PENETRATIONS IN WALL AND/OR FLOOR ASSEMBLIES WITH AN APPROVED PRODUCT SYSTEM TO MAINTAIN REQUIRED FIRE RATING AND ACOUSTICAL MINIMUMS. 15. THESE ARCHITECTURAL DRAWINGS SHALL BE READ IN CONJUNCTION WITH SURVEY, STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS. 16. ALL CEILING HEIGHTS SHOWN ON THE REFLECTED CEILING PLANS ARE RELATED TO A CLEAR DIMENSION ABOVE THE FLOOR LOCATED DIRECTLY BELOW THE CEILING. 17. ALL INTERIOR FRAMED PARTITIONS ARE TO BE BRACED BACK TO THE STRUCTURE ABOVE THE SUSPENDED CEILING SYSTEM USING METAL STUD @ MAXIMUM 1200mm O.C. EACH SIDE OF WALL. 18. WHERE FRAMED DRYWALL PARTITIONS ARE TO EXTEND UP TO THE UNDERSIDE OF ROOF OR FLOOR STRUCTURES PROVIDE A DOUBLE TOP TRACK ASSEMBLY TO ALLOW FOR A VERTICAL DEFLECTION OF 25mm, TYPICAL. TRACK ASSEMBLY SHALL CONSIST OF A 50mm DEEP TRACK AND STANDARD TRACK IN COMBINATION WITH WALL BOARD FASTENED TO STUD ONLY. THE JUNCTIONS OF THE TRACK TO STRUCTURE AND GYPSUM BOARD TO THE TRACK MUST BE CAULKED AIR TIGHT. 19. IN EXTERIOR WALLS WHERE DISSIMILAR SUBSTRATES MEET LAP THE JOINT OF THE DISSIMILAR SUBSTRATES WITH AIR/MOISTURE BARRIER (AMB/AVB) MEMBRANE TO MINIMUM 150mm EACH SIDE OF THE JOINT. TYPICAL AT ALL HORIZONTAL AND VERTICAL JOINTS. REFER ALSO TO SECTION AND PLAN DETAILS, TYPICAL.
BDC1 LOT FRONTAGE EXTERIOR SIDE & FRONT YARD DEPTH INTERIOR SIDE & REAR YARD DEPTH LOT COVERAGE MAX. LANDSCAPE OPEN SPACE MIN. PARKING REQUIRED 6.0m MIN. 6.0m MIN. 6.0m MIN. 45% MIN. 30% MIN. RESIDENTIAL -1/UNIT RESTAURANT -1/15 m FOOD STORE -1/25 m TAVERN -1/6 m OFFICE -1/40 m PROVIDED 3.0m MIN. 3.0m MIN. 1.0m MIN. 35% MIN. 30% MIN. RESIDENTIAL -1/UNIT RESTAURANT -1/15 m FOOD STORE -1/25 m TAVERN -1/6 m OFFICE -1/40 m MAIN RESIDENTIAL ENTRANCE SECONDARY RESIDENTIAL ENTRANCE MAIN COMMERCIAL ENTRANCE SECONDARY
ENTRANCE
W/ 12m RADIUS
AND TEMP. TRUCK LOADING & DROP-OFF AREA (NO PARKING ZONE)
LINE BUILDING SETBACKS STOP SIGN -ALL PARKING AISLES TO BE CONTROLLED WITH STOP SIGNS-ACCESS OFF THE SIGHT SHALL BE CONTROLLED THROUGH THE USE A STOP IN ACCORDANCE WITH M.T.O STANDARDS. 6m SIGHT TRIANGLE @ INTERSECTIONS TACTILE SURFACE CAST IN EXTERIOR CONC. SIDEWALK MOLLOCK -REFER TO SPECIFICATIONS FOR DETAILS. FIRE DEPARTMENT CONNECTION. REFER TO SPECS FOR DETAILS. STOP M
HARD WOOD TREES -REFER TO LANDSCAPE DRAWINGS -OWNER TO CONFIRM SPECIES. SHRUBBERY -REFER TO LANDSCAPE DRAWINGS OWNER TO CONFIRM SPECIES. SOD -REFER TO LANDSCAPE DRAWINGS -OWNER TO CONFIRM SPECIES. MAIN RESIDENTIAL ENTRANCE SECONDARY RESIDENTIAL ENTRANCE MAIN COMMERCIAL ENTRANCE SECONDARY COMMERCIAL ENTRANCE EMERGENCY SERVICE EXITS BARRIER FREE ROOF DRAIN. REFER TO MANUFACTURER'S SPECIFICATIONS FOR DETAILS. LINEAR ROOF DRAIN. REFER TO MANUFACTURER'S SPECIFICATIONS FOR DETAILS.
SYMBOL LEGEND DOUBLE HEAD EMERGENCY LIGHTING (SEE OBC NOTE 7) ANNUNCIATOR AND ZONE INDICATION (SEE OBC NOTE 3) SMOKE AND HEAT DETECTOR (SEE NOTE 5) FIRE HOSE CABINET FIRE EXTINGUISHER (SEE OBC NOTE 8) MANUAL PULL STATION (SEE OBC NOTE 11) SMOKE ALARM w/ AUDIBLE AND VISUAL COMPONENT CARBON MONOXIDE DETECTOR 1 HR RATED FIRE SEPARATION WALL 1.5 HR RATED FIRE SEPARATION WALL 2 HR RATED FIRE SEPARATION WALL RF1 INVERTED PATIO ROOF RF2 INVERTED GREEN ROOF RF3 INVERTED GRAVEL ROOF -DRAINAGE RF4 SINGLE PLY EPDM MEMBRANE ROOF FIRE SEPARATIONS LEGEND BUILDING PLAN HATCH LEGEND MIN. LANDING WIDTH 1500 MIN. LANDING DEPTH 1500 CONCRETE SIDEWALK ASPHALT PAVING PAINTED PARKING LINE TYP. ADA PARKING SYMBOL TO BE PAINTED IN EVERY BARRIER FREE PARKING SPACE (TYP.) 1500 BARRIER FREE PARKING SPACE WIDTH (TYP.) 3400 3400 1500 610 MAX.10%FLARE TACTILE ATTENTION INDICATOR TO BE LOCATED TO INDENTIFY AN ENTRY INTO A VEHICULAR ROUTE OR AREA WHERE NO CURBS OR ANY OTHER ELEMENT SEPERATE THE VEHICULAR ROUTE OR AREA FROM A PEDESTRIAN ROUTE IN ACCORDANCE WITH OBC 3.8.3.2 DEPTH OF THE TACTILE ATTENTION INDICATOR TO BE NOT LESS THAN 300mm DEEP AND NOT MORE THAN 610mm IN ACCORDANCE WITH OBC 3.8.3.18 PROVIDE 1500mm 1500mm (MIN.) FLAT LANDING AT TOP OF CUT CURB. CUT CURB REFER TO SITE PLAN LEGEND (TYP.) AND MAX. SLOPE OF 1 IN 20 IN ACCORDANCE WITH OBC 3.8.3.2.
2731 150 B A R R I E R F R E E P A R K I N G S P A C E D E P T H T Y P ) 5500 10%FLARE SA CMA MPS EL DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A001 DRAWING STANDARDS, GENERAL NOTES & LEGENDS AD 04/17/21 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS TYPICAL BARRIER FREE PARKING SPACE ENLARGED PLAN
90mm BRICK VENEER 50mm AIR-SPACE W/ 22 Ga. CORRUGATED MASONRY WALL TIES R24 CLOSED CELL POLY-UTHERANE SPRAY FOAM EXTERIOR GRADE SHEATHING 140mm ENG. METAL STUDS @ 400mm C/C TYP. 13mm GYPSUM WALLBOARD 3" ALUMAX ACM PANEL (IVORY) 50mm AIR-SPACE W/ Z-GIRTS @ 600mm O.C. HORIZONTALLY R24 CLOSED CELL POLY-UTHERANE SPRAY FOAM EXTERIOR GRADE SHEATHING EXTERIOR GRADE SHEATHING 13mm GYPSUM WALLBOARD 3" ALUMAX ACM PANEL (PEARL BLACK) 50mm AIR-SPACE W/ Z-GIRTS @ 600mm O.C. HORIZONTALLY R24 CLOSED CELL POLY-UTHERANE SPRAY FOAM EXTERIOR GRADE SHEATHING 140mm ENG. METAL STUD @ 400 O/C TYP. 13mm GYPSUM WALLBOARD 90mm BRICK VENEER 70mm AIR-SPACE W/ 22 Ga. CORRUGATED MASONRY WALL TIES 3" ALUMAX ACM PANEL (PEARL BLACK) 140mm ENG. METAL STUD @ 400 O/C TYP. 3" ALUMAX ACM PANEL (PEARL BLACK) 3" ALUMAX ACM PANEL (IVORY) 140mm ENG. METAL STUD @ 400 O/C TYP. 3" ALUMAX ACM PANEL (IVORY) R24 CLOSED CELL POLY-UTHERANE SPRAY FOAM EXTERIOR GRADE SHEATHING EXTERIOR GRADE SHEATHING 13mm METAL CHANNELS @ 400mm O/C HOR. 13mm CEMENTIOUS BOARD 3" ALUMAX ACM PANEL (IVORY) 3" ALUMAX ACM PANEL (IVORY) 50mm AIR-SPACE W/ Z-GIRTS @ 600mm O.C. HORIZONTALLY R24 CLOSED CELL POLY-UTHERANE SPRAY FOAM EXTERIOR GRADE SHEATHING EXTERIOR GRADE SHEATHING 13mm METAL CHANNELS @ 400mm O/C HOR. 13mm CEMENTIOUS BOARD R24 CLOSED CELL POLY-UTHERANE SPRAY FOAM EXTERIOR GRADE SHEATHING 200mm ENG. METAL STUDS @ 400mm C/C TYP. EXTERIOR GRADE SHEATHING 13mm METAL CHANNELS @ 400mm O/C HOR. 13mm CEMENTIOUS BOARD 3" ALUMAX ACM PANEL (IVORY) 3" ALUMAX ACM PANEL (IVORY) 25mm DEEP Z-GIRTS @ 400mm O/C HORIZONTALLY EXTERIOR GRADE SHEATHING EXTERIOR GRADE SHEATHING 25mm DEEP Z-GIRTS @ 400mm O/C HORIZONTALLY 3" ALUMAX ACM PANEL (IVORY) 3" ALUMAX ACM PANEL (PEARL BLACK) 3" ALUMAX ACM PANEL (PEARL BLACK) 25mm DEEP Z-GIRTS @ 400mm O/C HORIZONTALLY EXTERIOR GRADE SHEATHING EXTERIOR GRADE SHEATHING 25mm DEEP Z-GIRTS @ 400mm O/C HORIZONTALLY 3" ALUMAX ACM PANEL (PEARL BLACK) C.I.P. POURED CONCRETE WALL C.I.P. POURED CONCRETE WALL 65mm METAL STUD @ 400 O.C. REFER TO STRUC. DWG'S 16mm TYPE 'X' GYPSUM WALLBOARD REFER TO ROOM FINISH SCHEDULE FOR FINISHES 16mm TYPE 'X' GYPSUM WALLBOARD REFER TO ROOM FINISH SCHEDULE FOR FINISHES 65mm METAL STUD @ 400 O.C. REFER TO STRUC. DWG'S C.I.P. POURED CONCRETE WALL 65mm METAL STUD @ 400 O.C. REFER TO STRUC. DWG'S 16mm TYPE 'X' GYPSUM WALLBOARD REFER TO ROOM FINISH SCHEDULE FOR FINISHES 16mm TYPE 'X' GYPSUM WALLBOARD REFER TO ROOM FINISH SCHEDULE FOR FINISHES 65mm METAL STUD @ 400 O.C. REFER TO STRUC. DWG'S C.I.P. POURED CONCRETE WALL 65mm METAL STUD @ 400 O.C. REFER TO STRUC. DWG'S 16mm TYPE 'X' GYPSUM WALLBOARD REFER TO ROOM FINISH SCHEDULE FOR FINISHES 13mm GYPSUM WALLBOARD REFER TO ROOM FINISH SCHEDULE FOR FINISHES 90mm METAL STUD @ 400 O.C. REFER TO STRUC. DWG'S 13mm GYPSUM WALLBOARD REFER TO ROOM FINISH SCHEDULE FOR FINISHES 90mm METAL STUD @ 400 O.C. REFER TO STRUC. DWG'S 13mm GYPSUM WALLBOARD REFER TO ROOM FINISH SCHEDULE FOR FINISHES 65mm METAL STUD @ 400 O.C. REFER TO STRUC. DWG'S 13mm GYPSUM WALLBOARD REFER TO ROOM FINISH SCHEDULE FOR FINISHES 16mm TYPE 'X' GYPSUM WALLBOARD REFER TO ROOM FINISH SCHEDULE FOR FINISHES 13mm RESILIENT CHANNEL @ 400mm O.C. HOR. 90mm METAL STUD @ 400 O.C. REFER TO STRUC. DWG'S 70mm AIR-SPACE 90mm METAL STUD @ 400 O.C. REFER TO STRUC. DWG'S 13mm RESILIENT CHANNEL @ 400mm O.C. HOR. 16mm TYPE 'X' GYPSUM WALLBOARD REFER TO ROOM FINISH SCHEDULE FOR FINISHES 50mm PAVING STONE 100mm ADJUSTABLE PLASTIC PEDESTAL R30 RIGID INSULATION 75mm SOIL LAYER 25mm HIGH DENSITY DRAINAGE BOARD R30 RIGID INSULATION 150mm COMPACTED GRANULAR R30 RIGID INSULATION 100mm C.I.P. CONC. SLAB ON GRADE C/W 6x6 W.W.M. & SLIP RESISTANT SURFACE IN ACCORDANCE O.B.C. 3.8.3.2 HIGH DENSITY R-15 RIGID INSULATION 150mm COMPACTED GRANULAR FILL 50mm SEDDUM LAYER 900mm C.I.P. CONCRETE TRANSFER SLAB 600mm C.I.P. CONCRETE TRANSFER SLAB WOOD SHAKES INTERLOCKING ROOF TILES BATTENS AND COUNTER BATTENS EXTERIOR GRADE SHEATHING 300mm C.I.P CONCRETE 25mm AIR-SPACE R-30 WOOD FIBRE INSULATION BOARD 13mm CEMENTIOUS BOARD 125mm DEEP Z-GIRTS 3" ALUMAX ACM PANEL (IVORY) CLT SLAB 314mm EXTERIOR GRADE SHEATHING 125mm DEEP Z-GIRTS 3" ALUMAX ACM PANEL (PEARL BLACK) EXTERIOR GRADE SHEATHING 3" ALUMAX ACM PANEL (PEARL BLACK) 3" ALUMAX ACM PANEL (PEARL BLACK) 70mm AIR-SPACE W/ 170mm Z-GIRT @ 400mm O.C.VERT. ALIGN W/ STUD 3" ALUMAX ACM PANEL (PEARL BLACK) 3" ALUMAX ACM PANEL (PEARL BLACK) 50mm AIR-SPACE W/ Z-GIRTS @ 600mm O.C. HORIZONTALLY 200mm ENG. METAL STUDS @ 400mm C/C TYP. EXTERIOR GRADE SHEATHING 140mm ENG. METAL STUDS @ 400mm C/C TYP. C.I.P. POURED CONCRETE WALL 470mm C.I.P REINFORCED CONCRETE FOUNDATION WALL. REFER TO STRUCTURAL DRAWINGS. HIGH DENSITY R-15 RIGID INSULATION. 13 140 13 127 50 90 432 13 140 13 127 50 76 419 13 140 13 127 50 76 419 140 13 70 90 313 76 140 76 292 76 140 76 292 444 ? 200mm ENG. METAL STUDS @ 400mm C/C TYP. 368 368 250 16 65 200 281 16 65 200 65 16 362 16 65 250 65 16 412 13 90 13 116 13 90 103 125 100 50 13 65 78 16 13 90 70 90 13 16 308 250 75 470 545 444 524 125 25 75 50 125 150 150 75 125 900 600 13 25 240 22 25 38 13 125 76 13 125 76 300 314 140mm ENG. METAL STUDS @ 400mm C/C TYP. 140mm ENG. METAL STUDS @ 400mm C/C TYP. DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN DATE NO.REVISIONBY REVISIONS KEY-PLAN School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: EXTERIOR WALL AND PARAPET WALL ASSEMBLIES F.R.R: ULC EQ.: TAG: EXWAHR.F.R.R: ULC EQ.: TAG: EXWAHR.F.R.R: ULC EQ.: TAG: EXWAHR.F.R.R: ULC EQ.: TAG: EXWAHR.F.R.R: ULC EQ.: TAG: EXWAHR.F.R.R: ULC EQ.: TAG: EXWAHR. F.R.R: ULC EQ.: TAG: PAWAHR. INTERIOR PARTITIONS F.R.R: S.T.C: TAG: HR.ULC EQ.: Min. F.R.R: S.T.C: TAG: HR.ULC EQ.: Min.
FLOOR
ASSEMBLIESROOF ASSEMBLIES F.R.R: ULC EQ.: TAG: FLHR.F.R.R: ULC EQ.: TAG: RFHR. COORDINATE ALL ASSEMBLIES TO THE LATEST VERSION OF THE ONTARIO BUILDING CODE AND ULC GUIDES. USE THIS SHEET IN CONJUNCTION WITH ALL SCHEDULES AND VIEWS. F.R.R: ULC EQ.: TAG: FLHR. SOFFIT ASSEMBLIES TAG: F.R.R: S.T.C: TAG: HR.ULC EQ.: Min. F.R.R: S.T.C: TAG: HR.ULC EQ.: Min. F.R.R: S.T.C: TAG: HR.ULC EQ.: Min. F.R.R: S.T.C: TAG: HR.ULC EQ.: Min. F.R.R: S.T.C: TAG: HR.ULC EQ.: Min. F.R.R: S.T.C: TAG: HR.ULC EQ.: Min. F.R.R: S.T.C: TAG: HR.ULC EQ.: Min. F.R.R: ULC EQ.: TAG: RFHR.F.R.R: ULC EQ.: TAG: RFHR. F.R.R: ULC EQ.: TAG: FLHR.F.R.R: ULC EQ.: TAG: FLHR. F.R.R: ULC EQ.: TAG: FLHR.F.R.R: ULC EQ.: TAG: FLHR. TAG: TAG: INTWAINTWAINTWAINTWAINTWA-INTWA-INTWA-INTWAFDNSF-SFBUILDING ENVELOPE ASSEMBLIES F.R.R: ULC EQ.: TAG: PAWAHR.F.R.R: ULC EQ.: TAG: PAWAHR.F.R.R: ULC EQ.: TAG: PAWAHR.F.R.R: ULC EQ.: TAG: PAWAHR.F.R.R: ULC EQ.: TAG: PAWAHR. ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 PN F.R.R: ULC EQ.: TAG: RFHR. FOUNDATION WALL ASSEMBLIES F.R.R: S.T.C: TAG: HR.ULC EQ.: Min.FDNF.R.R: S.T.C: TAG: HR.ULC EQ.: Min.FDNF.R.R: S.T.C: TAG: HR.ULC EQ.: Min.FDNA002 ASSEMBLY CONSTRUCTIONS AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS -1 -2 -3 -4 -5 -6 -5-4-3-1 -2 -1 -2 -3 -4 -5 -6 -7 -8 -1 -2 -3 -1 -2 -3 -5-4-4 -1 -2
FHC FHC 7-STOREY MIXED USE BUILDING BUILDING HEIGHT: 28.2 m 7-STOREYS BUILDING AREA: 2727.15 m GROSS AREA: 9991.83 m R MOV EX STING CONC CURB REP ACE W TH NEW ROL ED C P CONC CURB 236 0 4 095 1 PARAL EL PARK NG SPACES @ 6m DEEP 6m W DE 2 5 071 3 6PAR L EL PARK NG SPACES @ 6m D EP 2m W DE 3 3 5 2 6 5203 5 P A R A L L E L P A R K N G S P A C E S @ 5 5 m D E E P x 2 6 m W D E 27551 4584 2000 6000 7000 7000 60006000 7000 7000 6000 FIREACCESSROUTECLRADIUS 12000 1000 1000 1000 6000 7000 7000 6000 10001000 1000 1000 1000 1000 1000 8350 8350 1000 10001000 10002000 20006000 7000 70006000 2000 2000 2000 2000 2000 6000 2000 2000 2000200020002000 2000 8200 8200 82008200 8200 2000 5700 5700 2000 2000 6 0 4005 1000 1 A001 PROPERTY LINE N 19° 37 20" W 120 05 m M 150mm C.I.P. CONC. CURB REFER TO |A100 FOR DETAILS. STOPSTOP STOP WHITE PAINTED CROSS WALK LINES (TYP.) WHITE PAINTED CROSS WALK LINES (TYP.) WHITE PAINTED CROSS WALK LINES (TYP.) WHITE PAINTED CROSS WALK LINES (TYP.) FIRE ACCESS ROUTE IN ACCORDANCE WITH OBC 3.2.5.6 FIRE ACCESS ROUTE IN ACCORDANCE WITH OBC 3.2.5.6 FIRE ACCESS ROUTE IN ACCORDANCE WITH OBC 3.2.5.6 WHITE PAINTED CROSS WALK LINES (TYP.) WHITE PAINTED CROSS WALK LINES (TYP.) WHITE PAINTED CROSS WALK LINES (TYP.) FIRE DEPARTMENT CONNECTION REFER TO SITE PLAN LEGEND FOR DETAILS. EDGE OF FAR TO PFFE 8456 FIRE ACCESS ROUTE WIDTH MIN. 6000, PROVIDED7300 5665 7180 5340 1660 FIRE ACCESS ROUTE WIDTH MIN. 6000, PROVIDED- 7300 CUT CURB REFER TO SITE PLAN LEGEND (TYP.) CUT CURB REFER TO SITE PLAN LEGEND (TYP.) TRUCK LOADING DROP OFF NO PARKING REFUGE TRUCK PARKING ONLY 1650 5500 7300 3162 2600 6+1 SPACES @ 2.6m WIDE x 5.5m DEEP 15600 4310 2600 7+1 SPACES @ 2.6m WIDE 5.5m DEEP 18200 7489 6848 7232 2600 8+1 SPACES @ 2.6m WIDE x 5.5m DEEP 20800 3703 7000 3883 2500 3575 M 7150 2745 2600 9+1 SPACES @ 2.6m WIDE x 5.5m DEEP 23400 4227 2600 7+1 SPACES @ 2.7m WIDE 5.5m DEEP 18200 7489 6848 7150 2600 11+1 SPACES @ 2.6m WIDE x 5.5m DEEP 28600 2985 3883 1000 7232 5065 14356 7682 7000 3883 19874 6848 6486 4 + 1 S P A C E S @ 2 6 m W D E x 5 5 m D E E P 10400 2600 6474 4 + 1 S P A C E S @ 2 6 m W D E x 5 5 m D E E P 10400 2600 1649 3550 1649 6232 6934 2850 5500 6232 7 8 3 9 27198 6m SIGHT TRIANGLE ENSURE NO FEATURES, BUILDING OR LANDSCAPING OVER 1.2m IN HEIGHT IS WITHIN HATCHED AREA. 5 4 7 5 5 2 0 27 4 4 8 27743 35601 4005 SOD SOD SOD SOD SOD SOD SOD SOD SOD SOD SOD PROVIDE TACTILE SURFACE IN ACCORDANCE WITH OBC 3.8.3.2.(1)(h)(TYP.) PATIO PATIO CONCRETE SIDE WALK REFER TO DETAIL 1/A100 FOR SIDE WALK CONSTRUCTION (TYP.) CONCRETE SIDE WALK REFER TO DETAIL 1/A100 FOR SIDE WALK CONSTRUCTION (TYP.) CONCRETE SIDE WALK REFER TO DETAIL 1/A100 FOR SIDE WALK CONSTRUCTION (TYP.) CONCRETE SIDE WALK REFER TO DETAIL 1/A100 FOR SIDE WALK CONSTRUCTION (TYP.) 150mm C.I.P. CONC. CURB. REFER TO 2|A100 FOR DETAILS. 150mm C.I.P. CONC. CURB REFER TO 2 |A100 FOR DETAILS. 150mm C.I.P. CONC. CURB REFER TO 2|A100 FOR DETAILS. PROPOERTY LINE N 68° 44' 22" E 74.86 m BIKE RACK PROPOERTY LINE N 68° 44' 21" E 71.42 m PROPERTY LINE S 21° 15' 39" 75.00 m EVERY FIRE DEPARTMENT SIAMESE CONNECTION SHALL BE LOCATED ON THE OUTSIDE OF A BUILDING ADJACENT TO A STREET OR AN ACCESS ROUTE, AT LEAST 300mm AND NOT MORE THAN 900mm ABOVE GROUND. FIREACCESSROUTECLRADIUS 12000 FIREACCESSROUTECLRADIUS 12000 MAIN RESIDENTIAL ENTRANCE SECONDARY RESIDENTIAL ENTRANCE MAIN COMMERCIAL ENTRANCE SECONDARY COMMERCIAL ENTRANCE EMERGENCY SERVICE EXITS BARRIER FREE PARKING FIRE ROUTE ACCESS CENTRE LINE W/ 12m RADIUS REFUSE TRUCK AND TEMP. TRUCK LOADING DROP-OFF AREA (NO PARKING ZONE) SITE PLAN SYMBOL LEGEND PROPERTY LINE BUILDING SETBACKS STOP SIGN -ALL PARKING AISLES TO BE CONTROLLED WITH STOP SIGNS-ACCESS OFF THE SIGHT SHALL BE CONTROLLED THROUGH THE USE STOP IN ACCORDANCE WITH M.T.O STANDARDS. 6m SIGHT TRIANGLE @ INTERSECTIONS TACTILE SURFACE CAST IN EXTERIOR CONC. SIDEWALK MOLLOCK -REFER TO SPECIFICATIONS FOR DETAILS. FIRE DEPARTMENT CONNECTION. REFER TO SPECS FOR DETAILS. STOP M HARD WOOD TREES -REFER TO LANDSCAPE DRAWINGS -OWNER TO CONFIRM SPECIES. SHRUBBERY -REFER TO LANDSCAPE DRAWINGS -OWNER TO CONFIRM SPECIES. SOD -REFER TO LANDSCAPE DRAWINGS OWNER TO CONFIRM SPECIES. SITE PLAN LANDSCAPE LEGEND ZONING MATRIX BDC1 LOT FRONTAGE EXTERIOR SIDE & FRONT YARD DEPTH INTERIOR SIDE & REAR YARD DEPTH LOT COVERAGE MAX. LANDSCAPE OPEN SPACE MIN. PARKING REQUIRED 6.0m MIN. 6.0m MIN. 6.0m MIN. 45% MIN. 30% MIN. RESIDENTIAL -1/UNIT OFFICE -1/40 m RESTAURANT -1/15 m TAVERN -1/6 m FOOD STORE -1/25 m PROVIDED 3.0m 3.0m 1.0m 35% 30% RESIDENTIAL -1/UNIT OFFICE -1/40 m RESTAURANT -1/15 m TAVERN -1/6 m FOOD STORE -1/25 m 150150 150mm COMPACTED GRANULAR FILL. CONFIRM W/ CIVIL DRAWINGS. 50mm ASPHALT FINISH COAT 50mm ASPHALT BASE COAT 350mm CLEAN 'GRADE 'A' TOP SOIL. CONFIRM WITH LANDSCAPE CONSULTANT. SOD -REFER TO LANDSCAPE DRAWINGS. 100 100 C.I.P. CONCRETE SIDEWALK r/w 6/6 6x6 WWM c/w SLIP RESISTANT SURFACE IN ACCORDANCE WITH OBC 3.8.3.2. R-10 RIGID FOAM INSULATION 150mm COMPACTED GRANULAR FILL. CONFIRM W/ CIVIL DRAWINGS. PROVIDE RADIANT IN-FLOOR HEATING LINES FOR WINTER SNOW REMOVAL WELDED WIRE MESH REINFORCING STEEL DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A100 ARCHITECTURAL SITE PLAN AND SITE DETAILS AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 200 SITE PLAN -PROJECT NORTH 1 102 TYPICAL CURB DETAIL 1 10 TYPICAL EXTERIOR CONC. SIDEWALK1
UP FHC FHC FHC 1.O 1.O 583 4643 9392 2362 9342 4643 583 9626 3826 6174 10000 10090 499 2050 3658 2144 390 10105 10000 10000 9626 1.N 1.N 1.M 1.M 1.L 1.L 1.K 1.K 1.F 1.F 1.E 1.E 1.D 1.D 1.B 1.B 1.A 1.A 1.1 1.3 1.5 1.6 1.4 1.2 1.C 1.C 1.G 1.G 1.I 1.I 1.H 1.H 1.J 1.J 88188 1.P 1.P 1229 8419 1207 8771 1229 8771 1229 2352 6419 1376 2507 2400 2587 1376 6338 2352 1229 8771 1229 8771 1197 8428 1229 30383 1197 3414 1229 8596 3142 8129 1197 3446 1229 583 9626 3826 6174 10000 10090 499 2050 3658 2144 390 10105 10000 10000 9626 583 88188 1197 8397 11229 8771 1229 2317 10337 2400 3869 2000 2400 2068 2314 1232 8771 1229 8771 1229 8397 1197 EXWA EXWA EXWA EXWA EXWA EXWA 4 EXWA EXWA 4 EXWA 4 EXWA 4 EXWAEXWA EXWA 4 EXWA EXWA EXWA 4EXWA 4 EXWA EXWA 4 EXWA EXWA EXWA 1 EXWA EXWA 4 EXWA 1 EXWA 3 EXWA 1 EXWA EXWA EXWA 4 EXWA EXWA 4 EXWA 4 EXWA EXWA 4 EXWA 4 EXWA 4 EXWA 4 EXWA EXWA 4 EXWA EXWA EXWA EXWA 4 EXWA 4 EXWA EXWA EXWA 4 EXWA EXWA 1 EXWA EXWA EXWA EXWAEXWA 4 EXWA EXWA 4 EXWA EXWA EXWA EXWA EXWA EXWA EXWA EXWA EXWA EXWA 4 EXWA 4 EXWA EXWA 4 EXWA EXWA 4EXWA 4 EXWA EXWA EXWA 4 EXWA EXWA EXWA 4 EXWA EXWA 1 EXWA 4 EXWAEXWA EXWA 4 EXWA EXWA 4EXWA 4 EXWA EXWA 4 EXWA EXWA EXWA 4EXWA EXWA 4 EXWA 4 EXWA EXWA 4 EXWA EXWA EXWA EXWA EXWA EXWA 4 EXWA EXWA EXWA EXWA 4 EXWA EXWA EXWA EXWA EXWA 4 EXWA EXWA EXWA 4 EXWA EXWA D.01.02.05 D.01.02.04 D.01.02.06 D.01.02.07 D.01.02.08 D.01.02.02 EXWA 4 EXWA EXWA EXWA 4EXWA EXWA 4 EXWA 4 EXWA D.01.01.02 INTWA 1 INTWA INTWA 1 INTWA 1 INTWA 1INTWA INTWA 4 INTWA INTWAINTWA INTWA 1 INTWA INTWA 4 INTWA 1INTWA INTWA 1 INTWA 1 INTWA INTWA INTWA 2 INTWA 1 INTWA 2 INTWA 1 INTWA INTWA INTWA INTWA INTWA 1 INTWA INTWA 1 INTWA 1 INTWA INTWA 1 INTWA 1 INTWA 1 INTWA INTWA 7 INTWA 1INTWA 1 INTWA 1 INTWA 5 INTWA 5 INTWA 5 TAVERN 100 OFFICE 114 CONDO ENTRANCE LOBBY 113 MECH. ELEC. RM. 108 REFUSE RM. 106 RESTAURANT 102 STAIR 'A' CORRIDOR 109 STAIR 'A' 110 STAIR 'B' 104 STAIR 'B' LOBBY 103 MAIL ROOM 112 CONDO LOCKER 111 INTWA INTWA FOOD STORE 105 øTURNINGDIA 1500 TURNING DIA. ø 1500 øTURNINGDIA 1500 D.01.02.01 D.01.03.01 D.01.03.02 D.01.02.10 D.01.02.12 D.01.04.01 D.01.02.14 D.01.02.15 D.01.02.11 D.01.02.09 D.01.02.13 D.01.02.03 D.01.01.01 D.01.02.04-1 D.01.05.01 EXWA EXWA 4 EXWA EXWA EXWA EXWA 4 EXWA EXWA EXWA 4 EXWA 4 EXWA 1 VESTIBULE 101 SECONDARY VEST. 107 TURNING DIA. ø 1500 INTWA INTWA 1 1197 2317 1197 1144 8113 1440 982 720 9023 720 1180 2359 1156 CHUTE 114 ELEV. 1 116 ELEV. 2 117 45m TRAVEL DISTANCE -REFER TO OBC 3.4.2.5 HATCH AREA DENOTES PROPOSED LOCATIONS OF WASHROOMS -TENANT TO CONFIRM W/ INTERIOR DESIGNER. INTERIOR DESIGNER TO PROVIDE PROPOSED SUITE LAYOUT TO ARCHITECT FOR REVIEW AND COMPLETION OF WALL ASSEMBLIES AND LOCATIONS -REFER TO L100 WASHROOM CALCULATIONS A0.1 45m TRAVEL DISTANCE -REFER TO OBC 3.4.2.5 45m TRAVEL DISTANCE -REFER TO OBC 3.4.2.5 OUTDOOR PATIO 100.1 OUTDOOR PATIO 102.1 HATCH AREA DENOTES PROPOSED LOCATIONS OF WASHROOMS -TENANT TO CONFIRM W/ INTERIOR DESIGNER. INTERIOR DESIGNER TO PROVIDE PROPOSED SUITE LAYOUT TO ARCHITECT FOR REVIEW AND COMPLETION OF WALL ASSEMBLIES AND LOCATIONS -REFER TO L100 WASHROOM CALCULATIONS A0.1 HATCH AREA DENOTES PROPOSED LOCATIONS OF WASHROOMS TENANT TO CONFIRM W/ INTERIOR DESIGNER. INTERIOR DESIGNER TO PROVIDE PROPOSED SUITE LAYOUT TO ARCHITECT FOR REVIEW AND COMPLETION OF WALL ASSEMBLIES AND LOCATIONS -REFER TO L100 WASHROOM CALCULATIONS A0.1 GAR. RM. 102.17 ED.1 ED.1 ED.1 4 A501 2 A500 6 A501 1 A500 3 A500 5 A501 1 A600 EXWA 4 EXWA EXWA EXWA EXWA EXWA EXWA EXWA 2 A700 45m TRAVEL DISTANCE -REFER TO OBC 3.4.2.5 SERV. 115 583 300 9326 200 9800 200 9800 200 4714 5586 2014 3708 2138 3270 2352 4954 200 9800 200 9800 200 9426 583 INTWA 583 300 9226 3825 6275 200 9800 200 4714 5566 2788 2400 2668 5647 4954 200 9800 200 5875 3825 9726 583 INTWA 31.69 m 24 sec 31.69 m 24 sec 27.36 m 20 sec 13.79 m 10 sec 583 300 4143 8033 1460 2362 9442 200 3829 614 583 22.07 m 16 sec 22.07 m 16 sec 583 300 4172 9463 2362 2790 2810 1600 2212 4373 300 583 SPRINKLER PROTECTED GLAZED WALL ASSEMBLY -IN ACCORDANCE WITH 3.1.18. (1) SPRINKLER PROTECTED GLAZED WALL ASSEMBLY -IN ACCORDANCE WITH 3.1.18. (1) SPRINKLER PROTECTED GLAZED WALL ASSEMBLY -IN ACCORDANCE WITH 3.1.18. (1) SPRINKLER PROTECTED GLAZED WALL ASSEMBLY -IN ACCORDANCE WITH 3.1.18. (1) SPRINKLER PROTECTED GLAZED WALL ASSEMBLY -IN ACCORDANCE WITH 3.1.18. (1) SPRINKLER PROTECTED GLAZED WALL ASSEMBLY -IN ACCORDANCE WITH 3.1.18. (1) SPRINKLER PROTECTED GLAZED WALL ASSEMBLY -IN ACCORDANCE WITH 3.1.18. (1) SPRINKLER PROTECTED GLAZED WALL ASSEMBLY -IN ACCORDANCE WITH 3.1.18. (1) SPRINKLER PROTECTED GLAZED WALL ASSEMBLY -IN ACCORDANCE WITH 3.1.18. (1) POST SIGN STATING MAXIMUM OCCUPANT LOAD OF 150 PERSONS SUITE OCCUPNACY IN ACCORDANCE WITH OBC 3.1.17.1.(6) POST SIGN STATING MAXIMUM OCCUPANT LOAD OF 150 PERSONS SUITE OCCUPNACY IN ACCORDANCE WITH OBC 3.1.17.1.(6) POST SIGN STATING MAXIMUM OCCUPANT LOAD OF 150 PERSONS -SUITE OCCUPNACY IN ACCORDANCE WITH OBC 3.1.17.1.(6) POST SIGN STATING MAXIMUM OCCUPANT LOAD OF 150 PERSONS -SUITE OCCUPNACY IN ACCORDANCE WITH OBC 3.1.17.1.(6) POST SIGN STATING MAXIMUM OCCUPANT LOAD OF 121 PERSONS -SUITE OCCUPNACY IN ACCORDANCE WITH OBC 3.1.17.1.(6) REFER TO A801 FOR ENLARGED UTR FLOOR PLAN AND ELEVATIONS MPS EL MPS EL EL SA MPS MPS ELSA MPS MPS ELSA EL SA EL SA MPS MPS EL SA MPS MPS EL SA MPS EL EL MPS MPS EL SA D.01.05.02 EXWA EXWA 4 EXWA 4 EXWA SPRINKLER PROTECTED GLAZED WALL ASSEMBLY -IN ACCORDANCE WITH 3.1.18. (1) POST SIGN STATING MAXIMUM OCCUPANT LOAD OF 150 PERSONS -SUITE OCCUPNACY IN ACCORDANCE WITH OBC 3.1.17.1.(6) EXWA 3265 1125 SA CMA MPS EL DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION L100 WASHROOM CALCULATIONS SUITE 100: TAVERN OCCUPANT LOAD: 150 PERSONS (OBC 3.1.17.1 (6)) No. WATERCLOSETS SEX (OBC TABLE 3.7.4.3.E) MEN (75 PERSONS): 2 WATERCLOSETS 2 URINALS WOMEN (75 PERSONS): 4 WATERCLOSETS OBC 3.7.4.2.(3) EXCEPT AS PROVIDED IN SENTENCE (4), URINALS ARE PERMITTED TO BE SUBSTITUTED FOR WATER CLOSETS REQUIRED IN THIS SUBSECTION FOR MALES AND MAY BE COUNTED AS WATER CLOSETS PROVIDED THE NUMBER OF URINALS IS NOT MORE THAN, (b) TWO THIRDS OF THE REQUIRED NUMBER OF WATER CLOSETS IN ANY OTHER OCCUPANCY No. LAVATORIES: 2 LAVATORIES SEX OBC 3.7.4.2.(5) EXCEPT AS REQUIRED IN THIS SUBSECTION, AT LEAST ONE LAVATORY SHALL BE PROVIDED IN A ROOM CONTAINING ONE OR TWO WATER CLOSETS OR URINALS, AND AT LEAST ONE ADDITIONAL LAVATORY SHALL BE PROVIDED FOR EACH ADDITIONAL TWO WATER CLOSETS OR URINALS. SUITE 102 RESTUARANT OCCUPANT LOAD: 150 PERSONS (OBC 3.1.17.1 (6)) No. WATERCLOSETS SEX (OBC TABLE 3.7.4.3.E) MEN (75 PERSONS): 2 WATERCLOSETS 2 URINALS WOMEN (75 PERSONS): 4 WATERCLOSETS OBC 3.7.4.2.(3) EXCEPT AS PROVIDED IN SENTENCE (4), URINALS ARE PERMITTED TO BE SUBSTITUTED FOR WATER CLOSETS REQUIRED IN THIS SUBSECTION FOR MALES AND MAY BE COUNTED AS WATER CLOSETS PROVIDED THE NUMBER OF URINALS IS NOT MORE THAN, (b) TWO THIRDS OF THE REQUIRED NUMBER OF WATER CLOSETS IN ANY OTHER OCCUPANCY No. LAVATORIES LAVATORIES SEX OBC 3.7.4.2.(5) EXCEPT AS REQUIRED IN THIS SUBSECTION, AT LEAST ONE LAVATORY SHALL BE PROVIDED IN A ROOM CONTAINING ONE OR TWO WATER CLOSETS OR URINALS, AND AT LEAST ONE ADDITIONAL LAVATORY SHALL BE PROVIDED FOR EACH ADDITIONAL TWO WATER CLOSETS OR URINALS. SUITE 102 OFFICE OCCUPANT LOAD: 9.3m2 PERSON (OBC TABLE 3.1.17.1) 495.175m2 9.3m2 = 53.24 = 54 PERSONS No. WATERCLOSETS SEX (OBC TABLE 3.7.4.3.E) MEN (27 PERSONS): WATERCLOSETS URINALS WOMEN (27 PERSONS): WATERCLOSETS OBC 3.7.4.2.(4) IF ONLY TWO WATER CLOSETS ARE REQUIRED FOR MALES, ONE URINAL IS PERMITTED TO BE SUBSITUTED FOR ONE OF THE WATER CLOSETS. No. LAVATORIES LAVATORY SEX OBC 3.7.4.2.(5) EXCEPT AS REQUIRED IN THIS SUBSECTION, AT LEAST ONE LAVATORY SHALL BE PROVIDED IN A ROOM CONTAINING ONE OR TWO WATER CLOSETS OR URINALS, AND AT LEAST ONE ADDITIONAL LAVATORY SHALL BE PROVIDED FOR EACH ADDITIONAL TWO WATER CLOSETS OR URINALS. SUITE 107 FOOD STORE OCCUPANT LOAD: 3.7m2 PERSON (OBC TABLE 3.1.17.1) 465.662m2 3.7m2 125.85 = 126 PERSONS No. WATERCLOSETS SEX (OBC TABLE 3.7.4.3.E) MEN (63 PERSONS): 1 UNIVERSAL WASHROOM WOMEN (63 PERSONS): 1 UNIVERSAL WASHROOM OBC 3.7.4.8.(2)(b) WHERE THE TOTAL AREA OF THE MERCANTILE OCCUPANCY, EXCLUDING BASEMENTS, IS NOT MORE THAN 600m2 ,NOT MORE THAN ONE WATER CLOSET FOR EACH SEX NEED BE PROVIDED. No. LAVATORIES LAVATORY SEX OBC 3.7.4.2.(5) EXCEPT AS REQUIRED IN THIS SUBSECTION, AT LEAST ONE LAVATORY SHALL BE PROVIDED IN A ROOM CONTAINING ONE OR TWO WATER CLOSETS OR URINALS, AND AT LEAST ONE ADDITIONAL LAVATORY SHALL BE PROVIDED FOR EACH ADDITIONAL TWO WATER CLOSETS OR URINALS. MAIN RESIDENTIAL ENTRANCE SECONDARY RESIDENTIAL ENTRANCE MAIN COMMERCIAL ENTRANCE SECONDARY COMMERCIAL ENTRANCE EMERGENCY SERVICE EXITS BARRIER FREE ROOF DRAIN. REFER TO MANUFACTURER'S SPECIFICATIONS FOR DETAILS. LINEAR ROOF DRAIN. REFER TO MANUFACTURER'S SPECIFICATIONS FOR DETAILS. BUILDING PLAN SYMBOL LEGEND DOUBLE HEAD EMERGENCY LIGHTING (SEE OBC NOTE 7) ANNUNCIATOR AND ZONE INDICATION (SEE OBC NOTE 3) SMOKE AND HEAT DETECTOR (SEE NOTE 5) FIRE HOSE CABINET FIRE EXTINGUISHER (SEE OBC NOTE 8) MANUAL PULL STATION (SEE OBC NOTE 11) SMOKE ALARM w/ AUDIBLE AND VISUAL COMPONENT CARBON MONOXIDE DETECTOR 1 HR RATED FIRE SEPARATION WALL 1.5 HR RATED FIRE SEPARATION WALL 2 HR RATED FIRE SEPARATION WALL RF1 INVERTED PATIO ROOF RF2 INVERTED GREEN ROOF RF3 INVERTED GRAVEL ROOF -DRAINAGE RF4 SINGLE PLY EPDM MEMBRANE ROOF FIRE SEPARATIONS LEGEND BUILDING PLAN HATCH LEGEND DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A200 L100 COMMERCIAL & RESIDENTIAL LOBBY FLOOR PLAN AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 125 L100 -COMMERCIAL & RESIDENTIAL LOBBY FLOOR PLAN
W/D W/D W/D FHC FHC REF. REF. EM EM EM EM EM EM FHC MEDIA ROOM 202 ACTIVITY ROOM 207 YOGA/SPA STUDIO 211 GYM & FITNESS ROOM 214 BF SUITE 'A' 201 BF SUITE 'B' 200 BF SUITE 'A' 208 BF SUITE 'B' 209 MECH/ELEC ROOM 213.1 MECH HARVESTING 213.2 CUSTODIAL SUPPLY 213STAIR 'A' 210.2 STAIR 'B' 210.1 UTR-1 212.2 UTR-2 212.1 1.1 1.3 1.6 1.4 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.A 2.A 2.B 2.B 2.E 2.E 2.F 2.F 2.H 2.H 2.J 2.J 2.N 2.N 2.P 2.P 2.R 2.R 2.S 2.S 2.V 2.V 2.U 2.U 2.T 2.T 2.Q 2.Q 2.O 2.O 2.M 2.M 2.L 2.L 2.K 2.K 2.I 2.I 2.G 2.G 2.D 2.D 2.C 2.C 2.8 5201 2488 2117 1200 3029 2362 3029 1200 2117 2437 5202 173 5091 830 6284 3949 4941 3931 4960 3913 6436 6436 3913 4960 3931 4941 3949 6280 5091 173 400 1437 1587 720 720 1587 1800 1157 431 399 525 1587 1800 1587 784 2175 1587 188 1400 1587 1800 308 1800 1587 390 1198 1587 2175 784 1587 1541 259 1587 3390 1200 1200 3390 1587 259 1541 1587 784 2175 1587 1198 390 1587 1800 308 1800 1587 1400 188 1587 2175 784 1587 1800 1587 522 403 431 1157 1800 1587 720 720 1605 1437 392 30383 2220 2131 850 2096 392 1437 680 1200 2753 276 1311 1051 536 2493 1200 680 1437 392 2045 867 1930 2405 567 2787 2114 2963 1829 4633 1587 1587 4374 1828 2912 2114 2788 L200 ELEV. LOBBY 204 SERVICE 203 L200 CORRIDOR 204.1 ELEV.-1 206.1 ELEV.-2 206.2 CHUTE 205 GARB. RM. 205.1 EXWA EXWA 2 EXWA 2 EXWA EXWA 2 EXWA 173 5091 830 6284 3949 4941 3931 4960 3913 6436 6436 3913 4960 3931 4941 3949 6280 5091 173 392 1437 1802 678 5091 431 419 3568 890 1587 218 1594 1587 768 2156 1587 1198 390 1587 1800 308 1800 1587 1418 169 1587 2156 814 1587 1812 1587 635 636 1587 1812 1587 814 2156 1587 169 1418 1587 1800 308 1800 1587 390 1198 1587 2156 768 1587 1594 218 1587 4476 402 431 5091 680 1818 1437 392 EXWA 2 EXWA EXWAEXWAEXWA EXWA 3 EXWA 2 EXWA 2 EXWA 2 W1 W1 W3 W1WC-1 W1 W1 WC-1 W3 W1 W3 W1 W1 W1 W1 W1 W1 W1 W1 W3 W1 W1 W3 W1 W1 W1 W1 W1 W1 W1 W1 W3 W1 W1 W3 W1 W1 WC-1 W1 EXWA 6 W1 EXWA EXWA EXWA 3 EXWA 2 EXWA WC-1W3EXWA EXWA EXWA EXWA 6 W1 W1 W1 W1 W2 W1 EXWA 2EXWA 2EXWA 2 EXWA W1W2W1W1W1 W1W1W1W1W1W2W1 D.02.204.3 D.02.204.14 D.02.204.13 D.02.204.12 D.02.204.11 D.02.204.10 D.02.204.5 D.02.204.6 D.02.204.9 D.02.204.7 D.02.204.8D.02.204.15 D.02.204.1 D.02.204.2 INTWA 2 ED.1 INTWA 1 D.02.214.1.2 D.02.211.1.2 D.02.211.1.1 D.02.207.1 D.02.208.1D.02.202.1D.02.201.1 833 833 2.W 2.W 3762 3762 3744 3744 88521 88521 4 A501 2 A500 6 A501 1 A500 3 A500 5 A501 1 A600 MPS EL EL MPSELEL EL STORAGE 205.2 GARDEN PATIO OPEN PATIO GARDEN PATIO OPEN PATIO OPEN PATIO BALCONY BALCONY BALCONY BALCONY EXWA EXWA EXWAW1 W2 W1 W1 W1W1 D.02.214.1OPEN PATIO PAWA PAWA 1 PAWA 1 W SL 1 W SL 1 W SL 1 W SL 1 W SL 1 W SL 1 W SL 1 W SL 1 W SL 1 PAWA PAWA 1 PAWA PAWA 2 PAWA PAWA 1 PAWA PAWA 1 PAWA 2 PAWAPAWA 1 W SL 1W SL 1 W SL 1 W SL 1 W SL 1 W SL 1 W SL 1 W SL 1 W SL 1W SL 1 W SL 1 W SL 1 W SL 1 W SL 1 W SL 1 31.47 m 23 sec 45m TRAVEL DISTANCE REFER TO OBC 3.4.2.5 31.47 m 23 sec 45m TRAVEL DISTANCE REFER TO OBC 3.4.2.5 TYP. ROOF DRAIN AND INSPECTION CHAMBER. TYP. ROOF DRAIN AND INSPECTION CHAMBER. TYP. ROOF DRAIN AND INSPECTION CHAMBER. TYP. ROOF DRAIN AND INSPECTION CHAMBER. TYP. ROOF DRAIN AND INSPECTION CHAMBER. TYP. ROOF DRAIN AND INSPECTION CHAMBER. TYP. LINEAR ROOF DRAIN. TYP. LINEAR ROOF DRAIN. TYP. LINEAR ROOF DRAIN.TYP. LINEAR ROOF DRAIN. 4581 3589 2108 5341 5341 2108 3589 3589 7641 4592 1963 4592 7641 3589 1963 MAIN RESIDENTIAL ENTRANCE SECONDARY RESIDENTIAL ENTRANCE MAIN COMMERCIAL ENTRANCE SECONDARY COMMERCIAL ENTRANCE EMERGENCY SERVICE EXITS BARRIER FREE ROOF DRAIN. REFER TO MANUFACTURER'S SPECIFICATIONS FOR DETAILS. LINEAR ROOF DRAIN. REFER TO MANUFACTURER'S SPECIFICATIONS FOR DETAILS. BUILDING PLAN SYMBOL LEGEND DOUBLE HEAD EMERGENCY LIGHTING (SEE OBC NOTE 7) ANNUNCIATOR AND ZONE INDICATION (SEE OBC NOTE 3) SMOKE AND HEAT DETECTOR (SEE NOTE 5) FIRE HOSE CABINET FIRE EXTINGUISHER (SEE OBC NOTE 8) MANUAL PULL STATION (SEE OBC NOTE 11) SMOKE ALARM w/ AUDIBLE AND VISUAL COMPONENT CARBON MONOXIDE DETECTOR 1 HR RATED FIRE SEPARATION WALL 1.5 HR RATED FIRE SEPARATION WALL 2 HR RATED FIRE SEPARATION WALL RF1 INVERTED PATIO ROOF RF2 INVERTED GREEN ROOF RF3 INVERTED GRAVEL ROOF -DRAINAGE RF4 SINGLE PLY EPDM MEMBRANE ROOF FIRE SEPARATIONS LEGEND BUILDING PLAN HATCH LEGEND SA CMA MPS EL DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A201 L200 AMENITIES & B.F. SUITES FLOOR PLAN AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 125 L200 FLOOR PLAN
W/D W/D W/D REF. REF. REF. REF. REF. REF. REF. REF.REF. REF. W/DW/D W/D W/D W/DW/D FHCFHCFHC FHC SUITE 'C' 301 SUITE 'C' 302 SUITE 'C' 308 SUITE 'C' 309 SUITE 'D' 310 SUITE 'C' 312 SUITE 'C' 313 SUITE 'C' 314 SUITE 'C' 315 SUITE 'D' 300 L300 ELEV. LOBBY 304 STAIR 'B' 311.1 STAIR 'A' 311.2 1.A 1.A 1.3 1.5 1.4 1.2 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.A 2.A 2.B 2.B 2.E 2.E 2.F 2.F 2.H 2.H 2.J 2.J 2.N 2.N 2.P 2.P 2.R 2.R 2.S 2.S 2.V 2.V 2.U 2.U 2.T 2.T 2.Q 2.Q 2.O 2.O 2.M 2.M 2.L 2.L 2.K 2.K 2.I 2.I 2.G 2.G 2.D 2.D 2.C 2.C 2.8 558 2488 2117 1200 3029 2362 3029 1200 2117 2437 559 157 3587 173 5091 830 6284 3949 4941 3931 4960 3913 6436 6436 3913 4960 3931 4941 3949 6280 833 5091 173 3762 88363 2114 867 2096 392 1437 680 1200 2753 276 1311 1051 536 2493 1200 680 2045 867 1930 70 88521 157 3587 173 5091 830 6284 3949 4941 3931 4960 3913 6436 6436 3913 4960 3931 4941 3949 6280 833 5091 173 3762 392 1437 1587 720 720 1587 1800 1157 431 399 525 1587 1800 1587 784 2175 1587 188 1400 1587 1800 308 1800 1587 390 1198 1587 2175 773 1587 1553 247 1587 3401 1200 1200 3401 1587 247 1553 1587 773 2175 1587 1198 390 1587 1800 308 1800 1587 1400 188 1587 2175 785 1586 1800 1587 522 406 427 1157 1800 1587 720 720 1605 1437 392 1437 392 21096 2114 2963 1829 4633 1587 1587 4373 2912 2000 114 1829 392 1437 1800 680 5091 431 399 20 3568 890 1587 218 1583 1587 780 2156 1587 1198 390 1587 1800 308 1800 1587 1418 169 1587 2156 810 1587 1800 1587 652 640 1587 1800 1587 821 2156 1587 169 1418 1587 1800 308 1800 1587 390 1198 1587 2156 773 1587 1589 211 1587 4483 402 431 5091 680 1800 1455 392 EXWA EXWA 2 EXWA 2 EXWA 6EXWA EXWA 2 EXWA EXWA 2 EXWA 2EXWA 2EXWA EXWA 3 EXWA EXWA EXWA EXWA EXWA 2 EXWA 2 EXWA EXWA EXWAEXWA 3 EXWA 2 EXWA 2 EXWA 2 EXWA 2EXWA EXWA EXWAEXWAEXWA EXWA 6 W1 W1 W1 W1WC-1 W1 W1 WC-1 WC-1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 WC-1 W1 W1 WC-1WC-1 W1 W1 W1 W1 W1W1 W1 W1 W1 W1 W1 W1 W1W1W1W1W1 W1W1W1W1W1W1W1 D.03.304.1 D.03.304.13 D.03.304.2 D.03.304.12 D.03.304.3 D.03.304.11 D.03.304.5 D.03.304.10 D.03.304.9 D.03.304.6 D.03.304.8 D.03.304.7L300 CORRIDOR 304.1 SERVICE 303 CHUTE 305 GARB. RM. 306 ELEV. 307 ELEV. 307 2.W 2.W 4 A501 2 A500 6 A501 D.03.304.4-1 1 A500 3 A500 5 A501 1 A600 EXWA MPS EL EL MPS ELEL EL 31.47 m 23 sec 45m TRAVEL DISTANCE REFER TO OBC 3.4.2.5 31.47 m 23 sec 45m TRAVEL DISTANCE REFER TO OBC 3.4.2.5 MAIN RESIDENTIAL ENTRANCE SECONDARY RESIDENTIAL ENTRANCE MAIN COMMERCIAL ENTRANCE SECONDARY COMMERCIAL ENTRANCE EMERGENCY SERVICE EXITS BARRIER FREE ROOF DRAIN. REFER TO MANUFACTURER'S SPECIFICATIONS FOR DETAILS. LINEAR ROOF DRAIN. REFER TO MANUFACTURER'S SPECIFICATIONS FOR DETAILS. BUILDING PLAN SYMBOL LEGEND DOUBLE HEAD EMERGENCY LIGHTING (SEE OBC NOTE 7) ANNUNCIATOR AND ZONE INDICATION (SEE OBC NOTE 3) SMOKE AND HEAT DETECTOR (SEE NOTE 5) FIRE HOSE CABINET FIRE EXTINGUISHER (SEE OBC NOTE 8) MANUAL PULL STATION (SEE OBC NOTE 11) SMOKE ALARM w/ AUDIBLE AND VISUAL COMPONENT CARBON MONOXIDE DETECTOR 1 HR RATED FIRE SEPARATION WALL 1.5 HR RATED FIRE SEPARATION WALL 2 HR RATED FIRE SEPARATION WALL RF1 INVERTED PATIO ROOF RF2 INVERTED GREEN ROOF RF3 INVERTED GRAVEL ROOF -DRAINAGE RF4 SINGLE PLY EPDM MEMBRANE ROOF FIRE SEPARATIONS LEGEND BUILDING PLAN HATCH LEGEND SA CMA MPS EL DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A202 L300 500 TYP. RESIDENTIAL FLOOR PLAN AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 125 L300-L500 FLOOR PLAN TYP.
FHC FHC REF. REF. W/D W/DREF. REF. W/D REF.W/D W/D REF. FHC PENTHOUSE SUITE 'B' 601 PENTHOUSE SUITE 'C' 612 PENTHOUSE SUITE 'A' 600 PENTHOUSE SUITE 'B' 607 PENTHOUSE SUITE 'C' 610 PENTHOUSE SUITE 'A' 608 L600 CORRIDOR 604.1 GREEN ROOF 602.1 GREEN ROOF 611 GREEN ROOF 602.2 STAIR 'A' 609.2 STAIR 'B' 609.1 1.G 1.G 1.I 1.I 1.H 1.H 1.J 1.J L600 ELEV. LOBBY 604 6.C 6.D 6.E 6.H 6.I 6.J6.G 6.B 6.B 6.A 6.A 6.3 6.1 6.2 6.4 6.5 6.7 6.9 6.6 6.8 6.10 392 1437 215 1997 5371 392 1437 1111 205 1190 398 1587 205 975 683 764 392 2595 368 1652 1997 5763 2548 1395 2190 1658 764 2963 20930 392 1437 1587 635 205 1800 3785 392 1437 918 205 1587 1587 205 1098 1437 392 23714 629 2400 629 23714 392 1437 1098 205 1587 1587 205 918 1437 392 3785 1800 205 635 1587 1455 392 3659 6182 2356 3585 2535 22056 2050 3658 2144 21961 2535 3585 2356 6182 3677 6.F 6.K 6.K 6.L 6.L 88521 6.E1 6.F1 6.F2 6.H16.G16.G2 1812 7583 1829 1316 1587 1587 1190 1829 2963 3659 13102 3585 2535 17492 2050 3658 2144 17398 2535 3585 13102 3677 88521 368 1746 392 1857 1587 215 195 1800 1800 1985 419 3568 436 1800 1098 205 1587 1587 2051098 1437 392 30173 5525 392 1437 1098205 1587 1587 205 1098 1800 4424 1985 1800 1800 195 215 1587 438 1437 392 1728 368 368 1746 1829 2007 420 1800 3356 2838 3339 1800 478 1587 420 1839 1862 368 2131 1812 2007 420 1800 3356 2838 3271 1800 546 1587 420 1839 2230 444 1800 1781 2810 2577 419 2000 419 9463 1862 368 BALCONY 601.1.2 SERVICE 603 ELEV. 607 ELEV. 607 BALCONY 607.1.2 BALCONY 612.1.2 BALCONY 610.1.2 BALCONY 600.1.2 BALCONY 608.1.2 WC-1 EXWA 2W1 D.06.600.1 WC-1 W1 W1 WC-1 W1 D.06.601.1 WC-1 W1 W3 W3 W3 W1 W1 WC-1 W1 D.06.612.1 D.06.604.01 D.06.604.9 D.06.604.2 D.06.604.8 D.06.604.7 D.06.604.4 D.06.604.6 D.06.604.5 D.06.607.1 D.06.608.1 D.06.610.1 EXWA 2 EXWA 2 EXWA 2 EXWA 2 EXWA 2 EXWA 2 EXWA 2 EXWAEXWA 2 EXWA 2 EXWA 2 EXWAW1 W1 EXWA EXWA 2 EXWAEXWA 2 EXWA 2 EXWA 2 EXWA 2 EXWA EXWA 2 EXWA EXWA 2 EXWA EXWA EXWA 2 EXWA 2 WC-1W1 WC-1W1W1WC-1 W1 WC-1W1W3W3 W3W1W1WC-1 W1 W1 W1 EXWA ED.1 ED.1 ED.1 EXWA 3 EXWA EXWA EXWA 2 EXWAEXWA 4 A501 2 A500 6 A501 D.06.604.3 PAWA 2PAWA PAWA 4 PAWA PAWA 4 PAWA 4 1 A500 3 A500 5 A501 1 A600 5525 368 368 MPS MPS GARB. CHUTE 605 GARB. RM. 605.1 STORAGE 606 D.06.604.3.1 31.47 m 23 sec 45m TRAVEL DISTANCE REFER TO OBC 3.4.2.5 31.47 m 23 sec 45m TRAVEL DISTANCE REFER TO OBC 3.4.2.5 4490 6900 4842 5183 5077 4842 6900 EL EL ELEL EL 45414402 6340 4282 4412 7498 4282 6340 4402 MAIN RESIDENTIAL ENTRANCE SECONDARY RESIDENTIAL ENTRANCE MAIN COMMERCIAL ENTRANCE SECONDARY COMMERCIAL ENTRANCE EMERGENCY SERVICE EXITS BARRIER FREE ROOF DRAIN. REFER TO MANUFACTURER'S SPECIFICATIONS FOR DETAILS. LINEAR ROOF DRAIN. REFER TO MANUFACTURER'S SPECIFICATIONS FOR DETAILS. BUILDING PLAN SYMBOL LEGEND DOUBLE HEAD EMERGENCY LIGHTING (SEE OBC NOTE 7) ANNUNCIATOR AND ZONE INDICATION (SEE OBC NOTE 3) SMOKE AND HEAT DETECTOR (SEE NOTE 5) FIRE HOSE CABINET FIRE EXTINGUISHER (SEE OBC NOTE 8) MANUAL PULL STATION (SEE OBC NOTE 11) SMOKE ALARM w/ AUDIBLE AND VISUAL COMPONENT CARBON MONOXIDE DETECTOR 1 HR RATED FIRE SEPARATION WALL 1.5 HR RATED FIRE SEPARATION WALL 2 HR RATED FIRE SEPARATION WALL RF1 INVERTED PATIO ROOF RF2 INVERTED GREEN ROOF RF3 INVERTED GRAVEL ROOF -DRAINAGE RF4 SINGLE PLY EPDM MEMBRANE ROOF FIRE SEPARATIONS LEGEND BUILDING PLAN HATCH LEGEND SA CMA MPS EL DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A203 L600 PENTHOUSE LOWER LEVEL FLOOR PLAN AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 125 L600 FLOOR PLAN -PENTHOUSE LEVEL 1
FHC 2.E 1.G 1.G 1.I 1.I 1.H 1.H 1.J 1.J 6.C 6.C 6.D 6.D 6.E 6.E 6.H 6.H 6.I 6.I 6.J 6.J 6.G 6.G 6.B 6.B 6.A 6.A 6.3 6.1 6.2 6.4 6.5 6.7 6.9 6.6 6.8 6.10 6.F 6.F 6.K 6.K 6.L6.E1 6.E1 6.F1 6.F1 6.F2 6.F2 6.H1 6.G1 6.G1 6.G2 6.G2 1829 7583 1829 1316 1587 1587 1180 1839 2963 1652 1997 5763 2548 1395 2190 1658 764 2963 20930 182915871829112315871587130318291975 22368 2400 24343 182913031587158711231829642515871847 36596182235635852535 22056 205036582144 21961 25353585235661823677 88521 1812 7583 1829 1316 1587 1587 1190 1829 2963 36591310235852535174922050365821441739825353585131023677 88521 3921437438158741018001800198540240211800 1098 20513512361587205 1098 1437392186139214371098 205 15872361351205 1098 18004361230233941919851800180041015874201829 EXWA 2 EXWA 2 EXWA 2 EXWA 2 EXWA 2 EXWA 2 EXWA 2 EXWA EXWA EXWA EXWA EXWA EXWA 2 EXWA 2 EXWA 2 EXWA 2EXWA 2 EXWA 2 EXWA 2 EXWA EXWA EXWA EXWA EXWA 2 EXWA EXWA PAWAWC-2 W4 WC-2 W4 W4 WC-2 W4 WC-2 W4 W5 W5 W5 W4 W4 WC-2 W4 W4 W4 WC-2W4 WC-2W4W4WC-2 W4 WC-2W4W5W5 W5W4W4WC-2 W4 W4 W4 1829 2007 420 1800 1777 1587 436 957 928 1800 2048 1800 478 1587 478 1781 1812 2007 420 1800 3364 1393 928 1800 2048 1800 478 1587 420 1839 419 25 1800 1781 2810 3021 75 1800 519 9462 3764878 46 850886464385046886 2.W 2.W EXWA EXWA 4 A501 2 A500 6 A501 EXWA PAWA PAWA PAWA PAWA 3 PAWA 3 PAWA 3 PAWA 3 PAWA 3 PAWA PAWA PAWA 3 PAWA PAWA 3 PAWA 3 PAWA 3 EXWA 2 EXWA EXWA 2 EXWA 2 1 A500 3 A500 5 A501 1 A600 EXWAEXWA 2 PENTHOUSE SUITE 'B' 702 PENTHOUSE SUITE 'A' 705 PENTHOUSE SUITE 'C' 703 PENTHOUSE SUITE 'B' 706 PENTHOUSE SUITE 'A' 708 PENTHOUSE SUITE 'C' 707 OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW RAH RAH MAIN RESIDENTIAL ENTRANCE SECONDARY RESIDENTIAL ENTRANCE MAIN COMMERCIAL ENTRANCE SECONDARY COMMERCIAL ENTRANCE EMERGENCY SERVICE EXITS BARRIER FREE ROOF DRAIN. REFER TO MANUFACTURER'S SPECIFICATIONS FOR DETAILS. LINEAR ROOF DRAIN. REFER TO MANUFACTURER'S SPECIFICATIONS FOR DETAILS. BUILDING PLAN SYMBOL LEGEND DOUBLE HEAD EMERGENCY LIGHTING (SEE OBC NOTE 7) ANNUNCIATOR AND ZONE INDICATION (SEE OBC NOTE 3) SMOKE AND HEAT DETECTOR (SEE NOTE 5) FIRE HOSE CABINET FIRE EXTINGUISHER (SEE OBC NOTE 8) MANUAL PULL STATION (SEE OBC NOTE 11) SMOKE ALARM w/ AUDIBLE AND VISUAL COMPONENT CARBON MONOXIDE DETECTOR 1 HR RATED FIRE SEPARATION WALL 1.5 HR RATED FIRE SEPARATION WALL 2 HR RATED FIRE SEPARATION WALL RF1 INVERTED PATIO ROOF RF2 INVERTED GREEN ROOF RF3 INVERTED GRAVEL ROOF -DRAINAGE RF4 SINGLE PLY EPDM MEMBRANE ROOF FIRE SEPARATIONS LEGEND BUILDING PLAN HATCH LEGEND SA CMA MPS EL DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A204 L700 PENTHOUSE UPPER LEVEL FLOOR PLAN AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 125 L700 FLOOR PLAN -PENTHOUSE LEVEL 2
W/D W/D W/D W/D FHC FHC REF. W/D REF. W/D W/DREF. REF. W/D REF.W/D W/D REF. FHC 1.G 1.G 1.I 1.I 1.H 1.H 1.J 1.J 6.C 6.C 6.D 6.D 6.E 6.E 6.H 6.H 6.I 6.I 6.J 6.J 6.G 6.G 6.B 6.B 6.A 6.A 6.3 6.1 6.2 6.4 6.5 6.7 6.9 6.6 6.8 6.10 6.F 6.F 6.K 6.K 6.L 6.L 6.E1 6.F1 6.F2 6.H16.G16.G2 W SL 1 W SL 1 W SL 1 W SL 1 W SL 1 W SL 1 W SL 1 W SL 1 3659 6182 2356 3585 2535 22056 2050 3658 2144 21961 2535 3585 2356 6182 3677 88521 3659 6182 2356 3585 979 1556 2029 2535 17492 2050 3658 2144 17398 2535 2029 2535 3585 2356 6182 3677 88521 5% SLOPE 5% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE W SL W SL W SL W SL W SL 1 W SL 1 W SL 1 W SL 1 W SL 1 W SL 1 W SL 1 W SL 1 W SL 1 W SL 1 W SL 1 W SL 1 W SL 1 W SL 1W SLW SL 5% SLOPE 5% SLOPE 2% SLOPE 2% SLOPE2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE W SL 1 2% SLOPE2% SLOPE2% SLOPE RF RF 4 RF 4 RF RF 4 RF 4 RF 3 RF 3 PAWA 2 PAWA 5 PAWA 1 PAWA 1 PAWA 2 PAWA 2 PAWA 5 PAWA 2 PAWA 1652 1997 5763 2548 1395 2190 1658 764 2963 8412 2195 2838 7695 2963 15874052984270459575274051725405258745641453210221401616242761614011102144524564258740517254057527486529841992 98311210140517254052587 37568 25874051725405121019831 GARBAGE CHUTE VENTW SL RAH RAHRAH RAHRAH ROOF HATCH WITH GUARDRAILS NO LESS THAN 1070mm ROOF HATCH WITH GUARDRAILS NO LESS THAN 1070mm ROOF HATCH WITH GUARDRAILS NO LESS THAN 1070mm ROOF HATCH WITH GUARDRAILS NO LESS THAN 1070mm DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION SA CMA MPS ELMAIN RESIDENTIAL ENTRANCE SECONDARY RESIDENTIAL ENTRANCE MAIN COMMERCIAL ENTRANCE SECONDARY COMMERCIAL ENTRANCE EMERGENCY SERVICE EXITS BARRIER FREE ROOF DRAIN. REFER TO MANUFACTURER'S SPECIFICATIONS FOR DETAILS. LINEAR ROOF DRAIN. REFER TO MANUFACTURER'S SPECIFICATIONS FOR DETAILS. BUILDING PLAN SYMBOL LEGEND DOUBLE HEAD EMERGENCY LIGHTING (SEE OBC NOTE 7) ANNUNCIATOR AND ZONE INDICATION (SEE OBC NOTE 3) SMOKE AND HEAT DETECTOR (SEE NOTE 5) FIRE HOSE CABINET FIRE EXTINGUISHER (SEE OBC NOTE 8) MANUAL PULL STATION (SEE OBC NOTE 11) SMOKE ALARM w/ AUDIBLE AND VISUAL COMPONENT CARBON MONOXIDE DETECTOR 1 HR RATED FIRE SEPARATION WALL 1.5 HR RATED FIRE SEPARATION WALL 2 HR RATED FIRE SEPARATION WALL RF1 INVERTED PATIO ROOF RF2 INVERTED GREEN ROOF RF3 INVERTED GRAVEL ROOF -DRAINAGE RF4 SINGLE PLY EPDM MEMBRANE ROOF FIRE SEPARATIONS LEGEND BUILDING PLAN HATCH LEGEND DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A205 ROOF PLAN AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 125 ROOF PLAN
REF. W/D UP FHC REF. W/D 12 11 10 23 21 20 18 17 16 15 14 13 PART 'A' DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION 2.1 2.2 2.3 2.4 2.5 2.6 2.A 2.A 2.B 2.B 2.F 2.F 2.H 2.H 2.J 2.I 2.I 2.G 2.G 2.D 2.D 2.C 2.C 2.8 8421 MEDIA ROOM 102.2 GYM FLOOR AREA 214 4 A501 2 A500 1 A600 D.02.204.1 D.02.200.2.2D.02.200.2.1D.02.200.2 D.02.200.3 D.02.200.6 KITCHEN 200.5 DINING AREA 200.5.1 LIVING AREA 200.4 BEDROOM 200.3 MASTER BEDROOM 200.2 WIC 200.2.1 B.F. WASHROOM 200.2.2 LAUNDRY/ STORAGE 200.6 ENT. LOBBY 200.1 ENT. CLOSET BEDROOM 201.5 MASTER BEDROOM 201.6 B.F. WASHROOM 201.6.2 WIC 201.6.1 LAUNDRY/ STORAGE 201.2 ENT. CLOSET LIVING AREA 201.4 DINING AREA 201.3.1 KITCHEN 201.3 HALLWAY 201.1.1 ENT. LOBBY 201.1 WOMEN'S CHANGE RM WASHROOM 214.2 MEN'S CHANGE RM WASHROOM 214.1 STAIR 'A' 306.56 D.02.204.2 D.02.204.3D.02.201.6.2 D.02.201.6.1 D.02.201.6 D.02.201.5 D.02.201.2 D.02.204.14 D.02.204.13 590 2000 81 200 1195 65 200 65 1386 300 + 1 TRD 590 290 3190 530 1600 397 1600 265 1600 179100 6174 315 690 7142 725 315 2966 D.02.214.2D.02.214.1.1 DOOR TO BE EQUIPPED W/ AUTOMATIC CLOSURE. DOOR AND CLOSURES TO BE EQUIPPED W/ 1.5H FRR MPS MANUAL PULL STATION IN ACCORDANCE WITH OBC 3.2.4.18. FIRE HOSE CABINET IN ACCORDANCE WITH OBC 3.2.9.4. 1HR FRR FIRE SEPERATION OF DWELLING UNITS FROM REMAINDER OF BUILDING IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) PROVIDE SMOKE AND HEAT DETECTOR IN EXIT STAIR SHAFT IN ACCORDANCE WITH OBC 3.2.4.12. INTWA 1 SMOKE AND HEAT DETECOTR IN ACCORDANCE WITH OBC 3.2.4.12. ELEMERGENCY LIGHTING IN ACCORDANCE WITH OBC 3.2.7.3 EL 31.47 m 23 sec SA SA SA KITCHEN MILLWORK. REFER TO MILLWORK SCHEDULE. PROVIDE (1) SMOKE ALARM C/W STROBE AND AUDIBLE IN COMMON AREA (TYP.) BARRIER FREE DWELLING UNIT NOTES: 1. DOORS TO BE LOCATED 100mm OFF OF INTERIOR WALL CORNERS UNLESS NOTED OTHERWISE. 2. CLOSET DOORS TO BE CENTRED IN CLOSET WALLS UNLESS NOTED OTHERWISE. 3. ON LATCH SIDE OF ALL DOORS WITHIN BARRIER FREE PATH OF TRAVEL PROVIDE 300mm (MIN.) ON PUSH SIDE OF DOOR AND A MINIMUM OF 600mm (MIN.) ON PULL SIDE OF DOOR. 4. ALL ROOMS TO BE EQUIPPED WITH MINIMUM OF 1500mm Ø TURNING CICRLE. 5. BARRIER FREE UNITS TO BE EQUIPPED WITH A MINIMUM OF BARRIER FREE SHOWER OR TUB IN ACCORDANCE WITH OBC 3.8.3.13. SLEEPING ROOMS WITHIN DWELLING UNITS TO BE EQUIPPED WITH SMOKE ALARMS C/W STROBE LIGHT AND SOUND. 1HR FRR FIRE SEPARATION BETWEEN DWELLING UNITS IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) CMA PROVIDE (1) CARBON MONOXIDE ALARM IN EACH DWELLING UNIT (TYP.) SA SA SA SA SA CMA PROVIDE (1) SMOKE ALARM C/W STROBE AND AUDIBLE IN COMMON AREA (TYP.) PROVIDE (1) CARBON MONOXIDE ALARM IN EACH DWELLING UNIT (TYP.) KITCHEN MILLWORK. REFER TO MILLWORK SCHEDULE. SLEEPING ROOMS WITHIN DWELLING UNITS TO BE EQUIPPED WITH SMOKE ALARMS C/W STROBE LIGHT AND SOUND. WALLS SEPARATING DWELLING UNITS FROM EACH OTHER AND REMAINDER OF THE BUILDING TO HAVE A MINIMUM STC RATING OF STC 50 (TYP.) 1HR FRR FIRE SEPARATION BETWEEN DWELLING UNITS IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) ALL WORKOUT OUT EQUIPMENT IS NOT IN CONTRACT STRUCTURAL ENGINEERING CONSULTANT TO ACCOUNT FOR THIS LOAD. INTERIOR WALL TO BE FINISHED WITH FLOOR TO CEILING MIRRORS THIS WALL ONLY. INTWAINTWA INTWA 7 INTWA 7 INTWA INTWA 5 INTWA 5 INTWA 5 INTWA 5 INTWA 7 INTWA 7 INTWA INTWA 5 INTWA INTWA INTWA 5 INTWA INTWA 5 INTWA 7 INTWA INTWA INTWA INTWA INTWA INTWA 5 INTWA 7 INTWA 7 INTWA INTWA INTWA 5 INTWA 5 INTWA 5 INTWAINTWA 5 INTWA INTWA INTWA INTWAINTWA 7 INTWA INTWA INTWA 6 INTWA 7 INTWA 8 INTWAINTWA 5 INTWA 5 INTWA 5 INTWA INTWA INTWA INTWA 5 INTWA 5 A8013 2 5 4 WALLS SEPARATING DWELLING UNITS FROM EACH OTHER AND REMAINDER OF THE BUILDING TO HAVE A MINIMUM STC RATING OF STC 50 (TYP.) ACOUSTICAL FABRIC PANEL TO COVER INSIDE OF SPANDREL PANEL (TYP.) SLIDIND ACOUSTICAL FABRIC PANEL TO COVER INSIDE OF PATIO DOOR (TYP.) INTWA INTWA INTWA INTWA 5 INTWA 7INTWA INTWAINTWA INTWA 7 INTWA 8 INTWA INTWA INTWA 7 INTWA INTWA 1 INTWA TURN NG D A ø 5 0 1504 TURN NG D A ø 1 00 T U R N N G D I A 1504 517 3127 441 1876 620 1607 1887 517 3925 620 1620 1004 2388 5786 461 1630 620 328 1333 833 1791 396 1380 646 2269 6557 315 55 1265 419 1048 2208 243 620 1013 620 77 1000 440 1863 419 1048 4524 996 2614 200 2162 200 6818 1200 665 448 419 BARRIER FREE DWELLING UNIT NOTES: 1. DOORS TO BE LOCATED 100mm OFF OF INTERIOR WALL CORNERS UNLESS NOTED OTHERWISE. 2. CLOSET DOORS TO BE CENTRED IN CLOSET WALLS UNLESS NOTED OTHERWISE. 3. ON LATCH SIDE OF ALL DOORS WITHIN BARRIER FREE PATH OF TRAVEL PROVIDE 300mm (MIN.) ON PUSH SIDE OF DOOR AND A MINIMUM OF 600mm (MIN.) ON PULL SIDE OF DOOR. 4. ALL ROOMS TO BE EQUIPPED WITH A MINIMUM OF 1500mm Ø TURNING CICRLE. 5. BARRIER FREE UNITS TO BE EQUIPPED WITH MINIMUM OF BARRIER FREE SHOWER OR TUB IN ACCORDANCE WITH OBC 3.8.3.13. INTWA 419163444138039615811343227621855070163419 8018 3609 DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A220 L200 ENLARGED FLOOR PLAN PART 'A' AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 50 L200 ENLARGED FLOOR PLAN -PART A

FIRE

FIRE

FIRE

EM EM EM EM EM EM PART 'B' 2.1 2.1 2.2 2.2 2.3 2.3 2.4 2.4 2.5 2.5 2.6 2.6 2.J 2.J 2.N 2.N 2.O 2.M 2.M 2.L 2.L 2.K 2.K 2.I 2.8 2.8 MEDIA ROOM 102.2 ACTIVITY ROOM 207 RW HARVESTING 213.2 MECH. ELEC. ROOM 213.1 CUSTODIAL SUPPLY JANITOR'S ROOM 213 2 A500 6 A501 1 A500 5 A501 L200 CORRIDOR 306.12 L200 ELEV. LOBBY 204 STORAGE RM. 205.2 B.F. TOILET 212.1 B.F. TOILET 212.2 SAUNA & HOT TUB 211.5 GARB. RM. 205.1 CHUTE 205 SERVICE 203 ELEV 1 206.1 ELEV. 2 206.2 D.02.204.12 D.02.213.1 D.02.213.2 ED.1 ED.1 ED.1 D.02.204.9D.02.204.11 D.02.204.10D.02.204.14 D.02.204.13 D.02.204.5D.02.204.4.1 D.02.204.4 315 2966 3819 1772 315 2655 3531 3531 4727 3666 293 3216 SMOKE AND HEAT DETECOTR IN ACCORDANCE WITH OBC 3.2.4.12. EL EMERGENCY LIGHTING IN ACCORDANCE WITH OBC 3.2.7.3 SMOKE AND HEAT DETECOTR IN ACCORDANCE WITH OBC 3.2.4.12. EMERGENCY LIGHTING IN ACCORDANCE WITH OBC 3.2.7.3 EL 1HR FRR FIRE SEPERATION OF DWELLING UNITS FROM REMAINDER OF BUILDING IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) EL 31.47 m 23 sec 31.47 m 23 sec RECEPTION & HALLWAY 211.1 INTERIOR WALL TO BE FINISHED WITH FLOOR TO CEILING MIRRORS THIS WALL ONLY. INTERIOR WALL TO BE FINISHED WITH FLOOR TO CEILING MIRRORS THIS WALL ONLY. A8013 2 4 1 A801 SMOKE AND HEAT DETECTOR IN ACCORDANCE WITH OBC 3.2.4.12. EMERGENCY LIGHTING IN ACCORDANCE WITH OBC 3.2.7.3 MEDIA SCREEN TO BE A MINIMUM SIZE 2.7m x 1.3m HIGH CONFIRM WITH SPECIFICATIONS. ACOUSTICAL FABRIC PANEL TO COVER INSIDE OF SPANDREL PANEL (TYP.) RAIN WATER HARVESTING STORAGE TANKS REFER TO MECHANICAL PLANS. BUILDING ELECTRICAL PANELS W/ METER REFER TO ELECTRICAL PLANS FOR DETAILS. FIRE DETECTOR IN ALL BUILDING SERVICE ROOMS NOT WITHIN DWELLING UNITS IN ACCORDANCE WITH OBC 3.2.4.11.
DETECTOR IN ALL BUILDING SERVICE ROOMS NOT WITHIN DWELLING UNITS IN ACCORDANCE WITH OBC 3.2.4.11.
DETECTOR IN ALL JANITOR ROOMS NOT WITHIN DWELLING UNITS IN ACCORDANCE WITH OBC 3.2.4.11
DETECTOR IN ACCORDANCE WITH OBC 3.2.4.11. FIRE DETECTOR IN ACCORDANCE WITH OBC 3.2.4.11. SERVICE SHAFT TO BE SEPARATED FROM REMAINDER OF THE BUILDING W/ A FIRE SEPARATION OF NOT CORRIDOR LESS THAN 1HR FRR OBC 3.6.2.1. ELEVATOR HOIST WAY TO BE SEPARATED FROM REMAINED OF THE BUILDING WITH A FIRE SEPARATION OF 1.5HR FRR IN ACCORDANCE WITH OBC 3.5.3.1. FIRE DETECTOR IN ACCORDANCE WITH OBC 3.2.4.11. ELEVATOR HOIST WAY TO BE SEPARATED FROM REMAINED OF THE BUILDING WITH A FIRE SEPARATION OF 1.5HR FRR IN ACCORDANCE WITH OBC 3.5.3.1. FIRE RATED GARBAGE CHUTE DOOR JANITOR'S MOP SINK JANITOR'S MOP SINK INTWA 7INTWA INTWA 7 INTWA 7 INTWA 7 INTWA INTWA INTWA INTWA INTWA 7 INTWA INTWA 8 INTWA 8 INTWA 8 INTWA INTWA 8 INTWA 8 INTWA 8 INTWA INTWA 8 INTWA INTWA 7 INTWA 7 INTWA INTWA INTWA 7 INTWA INTWA 1 INTWA 1 INTWA 2 INTWA 2 INTWA 2 INTWA 1 INTWA 2 INTWA 2 INTWA INTWA INTWA INTWA 1 TURNING DIA. 1500 TURN NG D A ø 1 0 315 6256 2014 3708 2094 6310 315 419 1048 4524 200 2162 200 665 448 419 200 521 5051 419 INTWA 7 THYSSENKRUPP SYNERGY SELF 2500 ELEVATOR. REFER TO PRODUCT SPECIFICATIONS. 8018 3609 3609 1048 4524 2162 200 665 448 419 8018 DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A220.1 L200 ENLARGED FLOOR PLAN PART 'B' AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 50 L200 ENLARGED FLOOR PLAN -PART B
REF. W/D FHC REF. 12 11 10 23 21 20 19 18 17 16 15 14 13 UP PART 'C' 2.1 2.1 2.2 2.2 2.3 2.3 2.4 2.4 2.5 2.5 2.6 2.6 2.P 2.P 2.R 2.R 2.V 2.V 2.U 2.U 2.T 2.T 2.Q 2.Q 2.O 2.O 2.8 2.8 ACTIVITY ROOM 207 6.L 2.W 2.W 3 A500 3 A700 WOMEN'S CHANGE RM WASHROOM 211.2 MEN'S CHANGE RM WASHROOM 211.3 YOGA ROOM 211.4 SAUNA & HOT TUB 211.5 STAIR 'B' 210.1 B.F. WASHROOM 209.6.2 WIC 209.6.1 MASTER BEDROOM 209.6 BEDROOM 209.5 B.F. WASHROOM 208.2.2 WIC 208.2.1 LAUNDRY/ STORAGE 208.6 BEDROOM 208.3 ENT. CLOSET ENT. CLOSET DINING AREA 208.5.1 LIVING AREA 208.4 KITCHEN 208.5 HALLWAY 208.1.1 ENT. LOBBY 208.1 LIVING AREA 209.4 DINING AREA 209.3.1 KITCHEN 209.3 LAUNDRY/ STORAGE 209.2 ENT. LOBBY 209.1D.02.204.9D.02.204.10 D.02.211.2 D.02.211.3 D.02.204.6D.02.208.2.2 D.02.208.2.1 D.02.208.2 D.02.208.3 D.02.208.6 D.02.209.2 D.02.209.5 D.02.204.7 D.02.204.8 D.02.209.6.2 D.02.209.6D.02.209.6.1 293 3216 656 7695 331 315 6239 200 79 1600 265 1600 105 419 2000 81 200 65 1130 65 200 65 1386 300 + TRD.590 290 3190 530 1600 389 101 290 300 290 DOOR TO BE EQUIPPED W/ AUTOMATIC CLOSURE. DOOR AND CLOSURES TO BE EQUIPPED W/ 1.5H FRR MANUAL PULL STATION IN ACCORDANCE WITH OBC 3.2.4.18. FIRE HOSE CABINET IN ACCORDANCE WITH OBC 3.2.9.4. 1HR FRR FIRE SEPERATION OF DWELLING UNITS FROM REMAINDER OF BUILDING IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) PROVIDE SMOKE AND HEAT DETECTOR IN EXIT STAIR SHAFT IN ACCORDANCE WITH OBC 3.2.4.12. SMOKE AND HEAT DETECOTR IN ACCORDANCE WITH OBC 3.2.4.12. EMERGENCY LIGHTING IN ACCORDANCE WITH OBC 3.2.7.3 MPSEL 31.47 m 23 sec INTERIOR GLASS WALL REFER TO CURTAIN WALL SCHEDULE. RECEPTION & HALLWAY 211.1 INTERIOR WALL TO BE FINISHED WITH FLOOR TO CEILING MIRRORS THIS WALL ONLY. SA SA SA KITCHEN MILLWORK. REFER TO MILLWORK SCHEDULE. PROVIDE (1) SMOKE ALARM C/W STROBE AND AUDIBLE IN COMMON AREA (TYP.) SLEEPING ROOMS WITHIN DWELLING UNITS TO BE EQUIPPED WITH SMOKE ALARMS C/W STROBE LIGHT AND SOUND. 1HR FRR FIRE SEPARATION BETWEEN DWELLING UNITS IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) CMA PROVIDE (1) CARBON MONOXIDE ALARM IN EACH DWELLING UNIT (TYP.) SA SA SA SA SA CMA PROVIDE (1) SMOKE ALARM C/W STROBE AND AUDIBLE IN COMMON AREA (TYP.) PROVIDE (1) CARBON MONOXIDE ALARM IN EACH DWELLING UNIT (TYP.) KITCHEN MILLWORK. REFER TO MILLWORK SCHEDULE. SLEEPING ROOMS WITHIN DWELLING UNITS TO BE EQUIPPED WITH SMOKE ALARMS C/W STROBE LIGHT AND SOUND. WALLS SEPARATING DWELLING UNITS FROM EACH OTHER AND REMAINDER OF THE BUILDING TO HAVE A MINIMUM STC RATING OF STC 50 (TYP.) 1HR FRR FIRE SEPARATION BETWEEN DWELLING UNITS IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) MASTER BEDROOM 208.2 PANTRY 207.1 D.02.207.1.1 WALLS SEPARATING DWELLING UNITS FROM EACH OTHER AND REMAINDER OF THE BUILDING TO HAVE A MINIMUM STC RATING OF STC 50 (TYP.) INTWAINTWA INTWA 7 INTWA 7 INTWA INTWA 7 INTWA INTWA INTWA INTWAINTWA INTWA 5 INTWA INTWA INTWA INTWA 7 INTWA INTWA 7INTWA 5 INTWA INTWA INTWA INTWA INTWA INTWA INTWA 7 INTWA 7INTWA INTWA INTWA 5 INTWA INTWA INTWA INTWA 5 INTWA 5 INTWA 5 INTWA 5INTWA INTWA INTWA INTWA INTWA INTWA 5 INTWAINTWA 5INTWA 5 INTWA 7 INTWA 7 INTWA 7 INTWA 7 INTWA 6 INTWA 7 INTWA INTWA INTWA INTWA 5 INTWA INTWA INTWA INTWA 5 INTWA INTWA INTWA INTWA TURN NG D A ø 1 0 TURNING DIA. 1504 TURN G D A ø 5 0 T U R N N G D I A 1504 2632 806 1380 396 1791 824 1342 328 620 1630 461 5676 3502 1620 620 3968 163 419 INTWA 5 INTWA 200 2614 996 521 5051 419 5173145441192157516071887 419 1048 2101 350 620 1013 575 122 1000 440 1863 INTWA 1 INTWA BARRIER FREE DWELLING UNIT NOTES: 1. DOORS TO BE LOCATED 100mm OFF OF INTERIOR WALL CORNERS UNLESS NOTED OTHERWISE. 2. CLOSET DOORS TO BE CENTRED IN CLOSET WALLS UNLESS NOTED OTHERWISE. 3. ON LATCH SIDE OF ALL DOORS WITHIN BARRIER FREE PATH OF TRAVEL PROVIDE 300mm (MIN.) ON PUSH SIDE OF DOOR AND A MINIMUM OF 600mm (MIN.) ON PULL SIDE OF DOOR. 4. ALL ROOMS TO BE EQUIPPED WITH A MINIMUM OF 1500mm Ø TURNING CICRLE. 5. BARRIER FREE UNITS TO BE EQUIPPED WITH A MINIMUM OF BARRIER FREE SHOWER OR TUB IN ACCORDANCE WITH OBC 3.8.3.13. BARRIER FREE DWELLING UNIT NOTES: 1. DOORS TO BE LOCATED 100mm OFF OF INTERIOR WALL CORNERS UNLESS NOTED OTHERWISE. 2. CLOSET DOORS TO BE CENTRED IN CLOSET WALLS UNLESS NOTED OTHERWISE. 3. ON LATCH SIDE OF ALL DOORS WITHIN BARRIER FREE PATH OF TRAVEL PROVIDE 300mm (MIN.) ON PUSH SIDE OF DOOR AND A MINIMUM OF 600mm (MIN.) ON PULL SIDE OF DOOR. 4. ALL ROOMS TO BE EQUIPPED WITH A MINIMUM OF 1500mm Ø TURNING CICRLE. 5. BARRIER FREE UNITS TO BE EQUIPPED WITH A MINIMUM OF BARRIER FREE SHOWER OR TUB IN ACCORDANCE WITH OBC 3.8.3.13. 3609 1048 4524 2814 2162 200 448 419 41444539 DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A220.2 L200 ENLARGED FLOOR PLAN PART 'C' AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 50 L200 ENLARGED FLOOR PLAN -PART C
W/D REF. REF. REF. W/D W/D UP UP 12 11 23 22 20 19 17 16 14 13 FHC FHC PART 'A' 2.1 2.1 2.2 2.2 2.3 2.3 2.4 2.4 2.5 2.5 2.6 2.6 2.7 2.7 2.A 2.A 2.B 2.B 2.E 2.E 2.F 2.F 2.H 2.H 2.J 2.J 2.I 2.I 2.G 2.G 2.D 2.D 2.C 2.C 2.8 2.8 4 A501 1 A600 A800 1 A800 3 BEDROOM 300.6 MASTER BEDROOM 300.4 WIC 300.4.1 ENSUITE 300.4.2 BATHROOM 300.2 LAUNDRY/STORAGE 300.3 LIVING AREA 300.7 DINING AREA 300.5.1 KITCHEN 300.5 ENTRANCE LOBBY 300.1 D.03.304.1 HALLWAY 300.1.1 ENTRANCE LOBBY 301.1 ENT. CLOSET HALLWAY 301.1.1 KITCHEN 301.2 DINING AREA 301.2.1 LIVING AREA 301.3 HALLWAY 301.1.2 BEDROOM 301.4 MASTER BEDROOM 301.5 WIC 301.5.1 ENSUITE 301.5.2 BATHROOM 301.6 LAUNDRY 301.7 D.03.304.2 KITCHEN 315.5 DINING AREA 315.5.1 LIVING AREA 315.4 HALLWAY 315.1.1 ENTRANCE LOBBY 315.1 BATHROOM 315.7 HALLWAY 315.1.2 BEDROOM 315.3 MASTER BEDROOM 315.2 ENSUITE 315.2.2 WIC 315.2.1 ENT. CLOSET LAUNDRY 315.6 MASTER BEDROOM 314.5 ENSUITE 314.5.2 WIC 314.5.1 HALLWAY 314.1.2 D.03.304.12 D.03.304.11 D.03.304.3 D.03.304.13 ENTRANCE LOBBY 302.1 ENT. CLOSET HALLWAY 302.1.2 BEDROOM 302.3 MASTER BEDROOM 302.2 WIC 302.2.1 ENSUITE 302.2.2 BATHROOM 302.7 LAUNDRY 302.6 ENT. CLOSET STAIR 'A' 311.2 SA SA SA SA SA SA SA SA SA SA SA SA SA SA SA CMA CMA CMA KITCHEN MILLWORK. REFER TO MILLWORK SCHEDULE. PROVIDE (1) SMOKE ALARM C/W STROBE AND AUDIBLE IN COMMON AREA (TYP.) DWELLING UNIT NOTES: 1. DOORS TO BE LOCATED 100mm OFF OF INTERIOR WALL CORNERS UNLESS NOTED OTHERWISE. 2. CLOSET DOORS TO BE CENTRED IN CLOSET WALLS UNLESS NOTED OTHERWISE. SLEEPING ROOMS WITHIN DWELLING UNITS TO BE EQUIPPED WITH SMOKE ALARMS C/W STROBE LIGHT AND SOUND. PROVIDE (1) CARBON MONOXIDE ALARM IN EACH DWELLING UNIT (TYP.) 1HR FRR FIRE SEPARATION BETWEEN DWELLING UNITS IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) PROVIDE (1) SMOKE ALARM C/W STROBE AND AUDIBLE IN COMMON AREA (TYP.) DWELLING UNIT NOTES: 1. DOORS TO BE LOCATED 100mm OFF OF INTERIOR WALL CORNERS UNLESS NOTED OTHERWISE. 2. CLOSET DOORS TO BE CENTRED IN CLOSET WALLS UNLESS NOTED OTHERWISE. PROVIDE (1) CARBON MONOXIDE ALARM IN EACH DWELLING UNIT (TYP.) KITCHEN MILLWORK. REFER TO MILLWORK SCHEDULE. PROVIDE (1) SMOKE ALARM C/W STROBE AND AUDIBLE IN COMMON AREA (TYP.) DWELLING UNIT NOTES: 1. DOORS TO BE LOCATED 100mm OFF OF INTERIOR WALL CORNERS UNLESS NOTED OTHERWISE. 2. CLOSET DOORS TO BE CENTRED IN CLOSET WALLS UNLESS NOTED OTHERWISE. PROVIDE (1) CARBON MONOXIDE ALARM IN EACH DWELLING UNIT (TYP.) KITCHEN MILLWORK. REFER TO MILLWORK SCHEDULE. 1HR FRR FIRE SEPARATION BETWEEN DWELLING UNITS IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) SLEEPING ROOMS WITHIN DWELLING UNITS TO BE EQUIPPED WITH SMOKE ALARMS C/W STROBE LIGHT AND SOUND. SLEEPING ROOMS WITHIN DWELLING UNITS TO BE EQUIPPED WITH SMOKE ALARMS C/W STROBE LIGHT AND SOUND. D.03.300.4 D.03.300.2D.03.300.3 D.03.300.6 D.03.300.4.2 D.03.303.6 D.03.301.5 D.03.301.4 D.03.301.5.2 D.03.315.3 D.03.315.2D.03.315.2.2 D.03.315.7 WALLS SEPARATING DWELLING UNITS FROM EACH OTHER AND REMAINDER OF THE BUILDING TO HAVE A MINIMUM STC RATING OF STC 50 (TYP.) 1HR FRR FIRE SEPARATION BETWEEN DWELLING UNITS IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". BALCONY 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". BALCONY BALCONY BALCONY1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". DOOR TO BE EQUIPPED W/ AUTOMATIC CLOSURE. DOOR AND CLOSURES TO BE EQUIPPED W/ 1.5H FRR MPS MANUAL PULL STATION IN ACCORDANCE WITH OBC 3.2.4.18. FIRE HOSE CABINET IN ACCORDANCE WITH OBC 3.2.9.4. 1HR FRR FIRE SEPERATION OF DWELLING UNITS FROM REMAINDER OF BUILDING IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) SLEEPING ROOMS WITHIN DWELLING UNITS TO BE EQUIPPED WITH SMOKE ALARMS C/W STROBE LIGHT AND SOUND. D.03.314.4 D.03.314.5D.03.314.5.2 WALLS SEPARATING DWELLING UNITS FROM EACH OTHER AND REMAINDER OF THE BUILDING TO HAVE A MINIMUM STC RATING OF STC 50 (TYP.) 1HR FRR FIRE SEPARATION BETWEEN DWELLING UNITS IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". PROVIDE SMOKE AND HEAT DETECTOR IN EXIT STAIR SHAFT IN ACCORDANCE WITH OBC 3.2.4.12. INTWA INTWA 5 INTWA INTWA 5 INTWA INTWA INTWAINTWA INTWA INTWA INTWA 5 INTWA INTWA 5 INTWA INTWA 7 INTWA INTWA INTWA INTWA INTWAINTWA 5 INTWA INTWA 5 392 125 2941 983 295 5273 65 200 158 5889 317 563 949 197 1444 1270 624 1026 620 1948 250 1858 620 1026 624 1270 1431 210 949 575 305 392 203 3036 1190 88 2129 1290 57 968 641 362 3463 362 6078 330 550 949 210 1431 1270 624 1026 2533 308 1797 620 1026 624 SMOKE AND HEAT DETECTOR IN ACCORDANCE WITH OBC 3.2.4.12. ELEMERGENCY LIGHTING IN ACCORDANCE WITH OBC 3.2.7.3 2114 406 110 419 1490 886 620 173 1172 779 620 4751 580 3250 163 419 2114 114 2000 210 210 71 1600 530 290 3190 590 1370 362 1098 362 2000 25 265 300 290 345 D.03.302.2 D.03.302.3 D.03.302.7 D.03.302.2.2 0 2000 81 200 1534 624 516 698 869 154 482 4725 1746 368 1712 225 399 516 751 816 154 4840 419 1746 368 WALLS SEPARATING DWELLING UNITS FROM EACH OTHER AND REMAINDER OF THE BUILDING TO HAVE A MINIMUM STC RATING OF STC 50 (TYP.) 1HR FRR FIRE SEPARATION BETWEEN DWELLING UNITS IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) INTWA 8 2114 419 448 678 3219 649 816 1267 624 1350 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". EL 31.47 m 23 sec 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". BALCONY 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". BALCONYBALCONY 6284 8891 8891 2 4 2 A702 419 448 154 1567 200 81 2000 0 81 2114 419 448 600 3207 636 919 648 516 624 1534 200 2000 DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A221 L300 500 ENLARGED FLOOR PLAN PART 'A' AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 50 L300-500 ENLARGED FLOOR PLAN -PART A
REF. REF. REF. REF. W/DW/D PART 'B' 1.3 1.3 1.4 1.4 2.1 2.1 2.2 2.2 2.3 2.3 2.4 2.4 2.5 2.5 2.6 2.6 2.7 2.7 2.J 2.N 2.O2.M2.L2.K2.I 2.8 2.8 2 A500 6 A501 1 A500 5 A501 KITCHEN 314.2 BATHROOM 314.6 BEDROOM 314.4 MASTER BEDROOM 314.5 ENSUITE 314.5.2 WIC 314.5.1 ENT. CLOSET 315.19 LAUNDRY 314.7 DINING AREA 314.2.1 HALLWAY 314.1.1 ENTRANCE LOBBY 314.1 HALLWAY 314.1.2 LIVING AREA 314.3 D.03.304.11 D.03.304.3 ENTRANCE LOBBY 302.1 ENT. CLOSET HALLWAY 302.1.1 KITCHEN 302.5 DINING AREA 302.5.1 LIVING AREA 302.4 HALLWAY 302.1.2 BEDROOM 302.3 BATHROOM 302.7 LAUNDRY 302.6 D.03.304.10 D.03.304.5 KITCHEN 313.5 BATHROOM 313.7 BEDROOM 313.3 MASTER BEDROOM 313.2 ENSUITE 313.2.2 WIC 313.2.1 ENT. CLOSET LAUNDRY 313.6 DINING AREA 313.5.1 HALLWAY 313.1.1 ENTRANCE LOBBY 313.1 HALLWAY 313.1.2 LIVING AREA 313.4 ENTRANCE LOBBY 308.1 HALLWAY 308.1.1 KITCHEN 308.2 DINING AREA 308.2.1 LIVING AREA 308.3 HALLWAY 308.1.2 BEDROOM 308.4 BATHROOM 308.6 SERVICE 303 ELEV. 307 ELEV. 2 307 CHUTE 305 GARB. RM. 306 LAUNDRY 308.7 ENT. CLOSET L300 ELEV. LOBBY 304 L300 CORRIDOR 304.1 SA SA SA SA SA SA SA SA SA SA SA SA SA SA CMA CMA PROVIDE (1) SMOKE ALARM C/W STROBE AND AUDIBLE IN COMMON AREA (TYP.) DWELLING UNIT NOTES: 1. DOORS TO BE LOCATED 100mm OFF OF INTERIOR WALL CORNERS UNLESS NOTED OTHERWISE. 2. CLOSET DOORS TO BE CENTRED IN CLOSET WALLS UNLESS NOTED OTHERWISE. KITCHEN MILLWORK. REFER TO MILLWORK SCHEDULE. SLEEPING ROOMS WITHIN DWELLING UNITS TO BE EQUIPPED WITH SMOKE ALARMS C/W STROBE LIGHT AND SOUND. D.03.314.4 D.03.314.5D.03.314.5.2 D.03.314.6 WALLS SEPARATING DWELLING UNITS FROM EACH OTHER AND REMAINDER OF THE BUILDING TO HAVE A MINIMUM STC RATING OF STC 50 (TYP.) 1HR FRR FIRE SEPARATION BETWEEN DWELLING UNITS IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". BALCONY 624 1270 1431 210 949 575 305 6214 65 200 61 1753 200 3443 65 200 1894 200 6108 317 563 949 210 1431 1270 624 308 1797 620 1026 624 1270 1431 210 949 588 292 6193 308 6077 330 550 949 210 1431 1270 624 1026 620 1913 308 SMOKE AND HEAT DETECTOR IN ACCORDANCE WITH OBC 3.2.4.12. EL EMERGENCY LIGHTING IN ACCORDANCE WITH OBC 3.2.7.3 D.03.313.7 D.03.313.2 D.03.313.3 D.03.312.2.2 D.03.308.6 D.03.308.5 D.03.308.4 D.03.302.2 D.03.302.3 D.03.302.7 CMA PROVIDE (1) CARBON MONOXIDE ALARM IN EACH DWELLING UNIT (TYP.) CMA PROVIDE (1) SMOKE ALARM C/W STROBE AND AUDIBLE IN COMMON AREA (TYP.) KITCHEN MILLWORK. REFER TO MILLWORK SCHEDULE. SLEEPING ROOMS WITHIN DWELLING UNITS TO BE EQUIPPED WITH SMOKE ALARMS C/W STROBE LIGHT AND SOUND. SMOKE AND HEAT DETECTOR IN ACCORDANCE WITH OBC 3.2.4.12. EMERGENCY LIGHTING IN ACCORDANCE WITH OBC 3.2.7.3 PROVIDE (1) CARBON MONOXIDE ALARM IN EACH DWELLING UNIT (TYP.) DWELLING UNIT NOTES: 1. DOORS TO BE LOCATED 100mm OFF OF INTERIOR WALL CORNERS UNLESS NOTED OTHERWISE. 2. CLOSET DOORS TO BE CENTRED IN CLOSET WALLS UNLESS NOTED OTHERWISE. EL 1HR FRR FIRE SEPERATION OF DWELLING UNITS FROM REMAINDER OF BUILDING IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) PROVIDE (1) SMOKE ALARM C/W STROBE AND AUDIBLE IN COMMON AREA (TYP.) DWELLING UNIT NOTES: 1. DOORS TO BE LOCATED 100mm OFF OF INTERIOR WALL CORNERS UNLESS NOTED OTHERWISE. 2. CLOSET DOORS TO BE CENTRED IN CLOSET WALLS UNLESS NOTED OTHERWISE. PROVIDE (1) CARBON MONOXIDE ALARM IN EACH DWELLING UNIT (TYP.) KITCHEN MILLWORK. REFER TO MILLWORK SCHEDULE. 1HR FRR FIRE SEPARATION BETWEEN DWELLING UNITS IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) PROVIDE (1) SMOKE ALARM C/W STROBE AND AUDIBLE IN COMMON AREA (TYP.) DWELLING UNIT NOTES: 1. DOORS TO BE LOCATED 100mm OFF OF INTERIOR WALL CORNERS UNLESS NOTED OTHERWISE. 2. CLOSET DOORS TO BE CENTRED IN CLOSET WALLS UNLESS NOTED OTHERWISE. PROVIDE (1) CARBON MONOXIDE ALARM IN EACH DWELLING UNIT (TYP.) KITCHEN MILLWORK. REFER TO MILLWORK SCHEDULE. 1HR FRR FIRE SEPARATION BETWEEN DWELLING UNITS IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) BALCONY 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". BALCONYBALCONY1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". 2114 114 305 1850 281 1350 260 2800 2871 2000 EL TURNING DIA. ø 1500 D.03.304.4-1 D.03.304.4 STORAGE RM. 306.1 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". BALCONY 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". BALCONY 6481 100 2014 554 2400 554 2094 100 6400 SMOKE AND HEAT DETECTOR IN ACCORDANCE WITH OBC 3.2.4.12. EMERGENCY LIGHTING IN ACCORDANCE WITH OBC 3.2.7.3 FIRE DETECTOR IN ACCORDANCE WITH OBC 3.2.4.11. FIRE DETECTOR IN ACCORDANCE WITH OBC 3.2.4.11. SERVICE SHAFT TO BE SEPARATED FROM REMAINDER OF THE BUILDING W/ A FIRE SEPARATION OF NOT CORRIDOR LESS THAN 1HR FRR OBC 3.6.2.1. ELEVATOR HOIST WAY TO BE SEPARATED FROM REMAINED OF THE BUILDING WITH A FIRE SEPARATION OF 1.5HR FRR IN ACCORDANCE WITH OBC 3.5.3.1. FIRE DETECTOR IN ACCORDANCE WITH OBC 3.2.4.11. ELEVATOR HOIST WAY TO BE SEPARATED FROM REMAINED OF THE BUILDING WITH A FIRE SEPARATION OF 1.5HR FRR IN ACCORDANCE WITH OBC 3.5.3.1. FIRE RATED GARBAGE CHUTE DOOR INTWA 2 INTWA INTWA INTWA 1 INTWA 2 INTWA 1 INTWAINTWA INTWA INTWA INTWA INTWA 2 INTWA 2 INTWA 1 INTWA INTWA INTWA 2 INTWA 2 INTWA 2 31.47 m 23 sec 31.47 m 23 sec THYSSENKRUPP SYNERGY SELF 2500 ELEVATOR. REFER TO PRODUCT SPECIFICATIONS. 419 448 665 3283 482 154 1567 516 449 175 1444 200 81 2114 419 448 600 3207 636 919 648 516 624 1534 200 2000 DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A221.1 L300 500 ENLARGED FLOOR PLAN PART 'B' AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 50 L300-500 ENLARGED FLOOR PLAN -PART B
W/D W/D REF. REF. REF. W/D W/D FHC UP UP 23 22 21 20 19 18 16 15 1312 10 PART 'C' 1.3 1.4 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.N 2.P 2.R 2.V2.U2.T2.Q2.O 2.8 6.L 2.W 3 A500 D.03.304.10 D.03.304.7 D.03.304.6 D.03.304.9 D.03.304.5 BEDROOM 310.3 MASTER BEDROOM 310.5 WIC 310.5.1 ENSUITE 310.5.2 BATHROOM 310.7 LAUNDRY/STORAGE 310.6 LIVING AREA 310.2 DINING AREA 310.4.1 KITCHEN 310.4 ENTRANCE LOBBY 310.1 HALLWAY 310.1.1 ENTRANCE LOBBY 309.1 HALLWAY 309.1.1 KITCHEN 309.5 DINING AREA 309.5.1 LIVING AREA 309.4 HALLWAY 309.1.2 BEDROOM 309.3 MASTER BEDROOM 309.2 WIC 309.2.1 ENSUITE 309.2.2 BATHROOM 309.7 LAUNDRY 309.6 KITCHEN 312.2 DINING AREA 312.2.1 LIVING AREA 312.3 HALLWAY 312.1.1 ENTRANCE LOBBY 312.1 BATHROOM 312.6 HALLWAY 312.1.2 BEDROOM 312.4 MASTER BEDROOM 312.5 ENSUITE 312.5.2 WIC 312.5.1 LAUNDRY 312.7 MASTER BEDROOM 313.2 ENSUITE 313.2.2 WIC 313.2.1 HALLWAY 313.1.2 ENTRANCE LOBBY 308.1 HALLWAY 308.1.2 BEDROOM 308.4 MASTER BEDROOM 308.5 WIC 308.5.1 ENSUITE 308.5.2 BATHROOM 308.6 LAUNDRY 308.7 ENT. CLOSET ENT. CLOSET ENT. CLOSET ENT. CLOSET STAIR 'B' 311.1 SA SA SA SA SA SA SA SA SA SA SA SA SA SA SA CMA CMA CMA 317 563 949 210 1431 1270 624 1026 620 1948 250 1858 620 1026 624 1270 1418 223 949 880 6072 65 5208 270 995 412 2560 190 392 1270 624 1026 620 1913 308 1797 620 1026 624 1270 1431 210 949 588 292 6194 362 3463 362 641 884 6 999 300 2177 50 1228 3132 203 392 SA D.03.313.2 D.03.313.3 D.03.312.2.2 D.03.312.5.2 D.03.312.5 D.03.312.4 D.03.312.6 D.03.310.7 D.03.310.6 D.03.310.5.2 D.03.310.5 D.03.310.3D.03.309.2 D.03.309.3 D.03.309.7 D.03.309.2.2 D.03.308.6 D.03.308.5D.03.308.5.2 D.03.308.4 CMA KITCHEN MILLWORK. REFER TO MILLWORK SCHEDULE. PROVIDE (1) SMOKE ALARM C/W STROBE AND AUDIBLE IN COMMON AREA (TYP.) SLEEPING ROOMS WITHIN DWELLING UNITS TO BE EQUIPPED WITH SMOKE ALARMS C/W STROBE LIGHT AND SOUND. PROVIDE (1) CARBON MONOXIDE ALARM IN EACH DWELLING UNIT (TYP.) 1HR FRR FIRE SEPARATION BETWEEN DWELLING UNITS IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) PROVIDE (1) SMOKE ALARM C/W STROBE AND AUDIBLE IN COMMON AREA (TYP.) PROVIDE (1) CARBON MONOXIDE ALARM IN EACH DWELLING UNIT (TYP.) KITCHEN MILLWORK. REFER TO MILLWORK SCHEDULE. PROVIDE (1) SMOKE ALARM C/W STROBE AND AUDIBLE IN COMMON AREA (TYP.) PROVIDE (1) CARBON MONOXIDE ALARM IN EACH DWELLING UNIT (TYP.) KITCHEN MILLWORK. REFER TO MILLWORK SCHEDULE. 1HR FRR FIRE SEPARATION BETWEEN DWELLING UNITS IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) SLEEPING ROOMS WITHIN DWELLING UNITS TO BE EQUIPPED WITH SMOKE ALARMS C/W STROBE LIGHT AND SOUND. SLEEPING ROOMS WITHIN DWELLING UNITS TO BE EQUIPPED WITH SMOKE ALARMS C/W STROBE LIGHT AND SOUND. WALLS SEPARATING DWELLING UNITS FROM EACH OTHER AND REMAINDER OF THE BUILDING TO HAVE A MINIMUM STC RATING OF STC 50 (TYP.) 1HR FRR FIRE SEPARATION BETWEEN DWELLING UNITS IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". BALCONY 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". BALCONY DOOR TO BE EQUIPPED W/ AUTOMATIC CLOSURE. DOOR AND CLOSURES TO BE EQUIPPED W/ 1.5H FRR MANUAL PULL STATION IN ACCORDANCE WITH OBC 3.2.4.18. FIRE HOSE CABINET IN ACCORDANCE WITH OBC 3.2.9.4. 1HR FRR FIRE SEPERATION OF DWELLING UNITS FROM REMAINDER OF BUILDING IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) SLEEPING ROOMS WITHIN DWELLING UNITS TO BE EQUIPPED WITH SMOKE ALARMS C/W STROBE LIGHT AND SOUND. WALLS SEPARATING DWELLING UNITS FROM EACH OTHER AND REMAINDER OF THE BUILDING TO HAVE A MINIMUM STC RATING OF STC 50 (TYP.) 1HR FRR FIRE SEPARATION BETWEEN DWELLING UNITS IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) PROVIDE SMOKE AND HEAT DETECTOR IN EXIT STAIR SHAFT IN ACCORDANCE WITH OBC 3.2.4.12. SMOKE AND HEAT DETECTOR IN ACCORDANCE WITH OBC 3.2.4.12. EMERGENCY LIGHTING IN ACCORDANCE WITH OBC 3.2.7.3 WALLS SEPARATING DWELLING UNITS FROM EACH OTHER AND REMAINDER OF THE BUILDING TO HAVE A MINIMUM STC RATING OF STC 50 (TYP.) 1HR FRR FIRE SEPARATION BETWEEN DWELLING UNITS IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) DWELLING UNIT NOTES: 1. DOORS TO BE LOCATED 100mm OFF OF INTERIOR WALL CORNERS UNLESS NOTED OTHERWISE. 2. CLOSET DOORS TO BE CENTRED IN CLOSET WALLS UNLESS NOTED OTHERWISE. DWELLING UNIT NOTES: 1. DOORS TO BE LOCATED 100mm OFF OF INTERIOR WALL CORNERS UNLESS NOTED OTHERWISE. 2. CLOSET DOORS TO BE CENTRED IN CLOSET WALLS UNLESS NOTED OTHERWISE. DWELLING UNIT NOTES: 1. DOORS TO BE LOCATED 100mm OFF OF INTERIOR WALL CORNERS UNLESS NOTED OTHERWISE. 2. CLOSET DOORS TO BE CENTRED IN CLOSET WALLS UNLESS NOTED OTHERWISE. MPS EL 368 1746 419 4345 482 154 829 738 516 399 225 1444 200 65 65 200 65 1379 624 1254 829 636 3232 665 460 406 2114 200 1709 449 516 698 869 154 482 4725 1746 368 BALCONYBALCONY 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". BALCONY 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". 2114 419 98 406 1610 766 633 2124 620 4751 580 3250 163 419 1746 368 2114 210 210 71 1600 530 290 3190 590 1386 65 200 65 1130 65 200 81 2000 300 265 25 345 290 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". BALCONY 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". BALCONY BALCONY 8891 8891 6284 INTWA INTWA INTWA 1 INTWA 1 INTWA 1 INTWA INTWA 1 INTWA 1 INTWA 1 31.47 m 23 sec D.03.304.8 DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A221.2 L300 500 ENLARGED FLOOR PLAN PART 'C' AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 50 L300-500 ENLARGED FLOOR PLAN -PART C
FHC REF. W/D REF. W/D W/DREF. PART 'A' 2.7 2.A 6.C 6.C 6.D 6.D 6.E 6.B 6.B 6.A 6.3 6.3 6.1 6.1 6.2 6.2 6.4 6.4 6.5 6.5 6.7 6.7 6.9 6.6 6.6 6.8 6.8 6.10 6.10 6.F6.E1 6.E1 6.F1 6.F1 6.F2 6.F2 4 A501 2 A500 1 A600 DOOR TO BE EQUIPPED W/ AUTOMATIC CLOSURE. DOOR AND CLOSURES TO BE EQUIPPED W/ 1.5H FRR MPS MANUAL PULL STATION IN ACCORDANCE WITH OBC 3.2.4.18. FIRE HOSE CABINET IN ACCORDANCE WITH OBC 3.2.9.4. 1HR FRR FIRE SEPERATION OF DWELLING UNITS FROM REMAINDER OF BUILDING IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) PROVIDE SMOKE AND HEAT DETECTOR IN EXIT STAIR SHAFT IN ACCORDANCE WITH OBC 3.2.4.12. EXWA SMOKE AND HEAT DETECTOR IN ACCORDANCE WITH OBC 3.2.4.12. ELEMERGENCY LIGHTING IN ACCORDANCE WITH OBC 3.2.7.3 EL ENT. LOBBY 600.1 HALLWAY 600.1.1 ENT. CLOSET LIVING AREA 600.5 DINING AREA 600.4.1 KITCHEN 600.4 LAUNDRY STORAGE 600.3 POWDER RM. 600.2 STAIRS 600.6 EXWAINTWA 1 INTWA 1 INTWA 1 INTWA 1 INTWA INTWA 1 LIVING AREA 601.5 DINIING AREA 601.4.1 KITCHEN 601.4 HALLWAY 601.1.1 ENT. LOBBY 601.1 ENT. CLOSET POWDER RM. 601.2 LAUNDRY STORAGE 601.3 STAIRS 601.6 KITCHEN 612.4 DINING AREA 612.4.1 ENT. LOBBY 612.1 HALLWAY 612.1.1 STAIRS 612.2 LIVING AREA 612.3 LAUNDRY STORAGE 612.5 POWDER RM. 612.6 ENT. CLOSET EXWA EXWA D.06.604.9 D.06.604.01 D.06.604.2 D.06.604.8D.06.612.6 D.06.612.7D.06.600.2 D.06.600.3 D.06.601.3 D.06.601.2 STAIRS 'B' 609.2 RF RF 2 RF RF 3 RF RF 1 RF 2 RF 3 RF RF RF RF 3 RF 3 RF RF RF 7780 31.47 m 23 sec SA SA CMA KITCHEN MILLWORK. REFER TO MILLWORK SCHEDULE. PROVIDE (1) SMOKE ALARM C/W STROBE AND AUDIBLE IN COMMON AREA (TYP.) DWELLING UNIT NOTES: 1. DOORS TO BE LOCATED 100mm OFF OF INTERIOR WALL CORNERS UNO. 2. CLOSET DOORS TO BE CENTRED IN CLOSET WALLS UNO. PROVIDE (1) CARBON MONOXIDE ALARM IN EACH DWELLING UNIT (TYP.) 1HR FRR FIRE SEPARATION BETWEEN DWELLING UNITS AND OTHER AREAS IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) SA CMA PROVIDE (1) SMOKE ALARM C/W STROBE AND AUDIBLE IN COMMON AREA (TYP.) PROVIDE (1) CARBON MONOXIDE ALARM IN EACH DWELLING UNIT (TYP.) DWELLING UNIT NOTES: 1. DOORS TO BE LOCATED 100mm OFF OF INTERIOR WALL CORNERS UNO. 2. CLOSET DOORS TO BE CENTRED IN CLOSET WALLS UNO. SA KITCHEN MILLWORK. REFER TO MILLWORK SCHEDULE. 1HR FRR FIRE SEPARATION BETWEEN DWELLING UNITS AND OTHER AREAS IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) KITCHEN MILLWORK. REFER TO MILLWORK SCHEDULE. 1HR FRR FIRE SEPARATION BETWEEN DWELLING UNITS AND OTHER AREAS IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) SA CMA PROVIDE (1) SMOKE ALARM C/W STROBE AND AUDIBLE IN COMMON AREA (TYP.) PROVIDE (1) CARBON MONOXIDE ALARM IN EACH DWELLING UNIT (TYP.) DWELLING UNIT NOTES: 1. DOORS TO BE LOCATED 100mm OFF OF INTERIOR WALL CORNERS UNO. 2. CLOSET DOORS TO BE CENTRED IN CLOSET WALLS UNO. SA 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". 9508 BALCONY EXTENDED GARDEN FROM BALCONY BALCONY RF 3 TYP. ROOF DRAIN AND INSPECTION CHAMBER. TYP. ROOF DRAIN AND INSPECTION CHAMBER. EXTENDED GARDEN FROM BALCONY TYP. ROOF DRAIN AND INSPECTION CHAMBER. EXTENDED GARDEN FROM BALCONY PAWA PAWA 4 PAWA PAWA PAWA PAWA 4 PAWA PAWA TYP. LINEAR ROOF DRAIN. TYP. LINEAR ROOF DRAIN. TYP. LINEAR ROOF DRAIN. 419 98 1337 315 1757 250 4502 1332 65 200 65 3495 65 200 65 1905 315 768 125 352 125 2793 315 893 1327 163 419 2278 1716 408 408 1283 368 1637 631 1716 408 408 1283 368 295 408 408 4346 333 1935 2315 1121 2278 392 640 1012 1997 473 408 408 3482 867 152 2000 419 101 550 845 2190 447 408 408 395 764 2323 640 4434 408 408 419 163 2107 125 190 1065 2205 125 201 1834 388 98 419 1935 1907 408 408 713 419 163 3347 315 2630 1231 1496 200 419 163 1337 315 1682 315 2682 1289 1348 200 419 163 2044 315 3266 315 1832 388 98 419 TYP. ROOF DRAIN AND INSPECTION CHAMBER. DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A222 L600 ENLARGED FLOOR PLAN PART 'A' AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 50 L600 ENLARGED FLOOR PLAN -PART A
PART 'B' 2.7 1.G 1.I1.H 1.J 6.3 6.3 6.1 6.1 6.2 6.2 6.4 6.4 6.5 6.5 6.7 6.7 6.9 6.6 6.6 6.8 6.8 6.10 6.10 2 A500 6 A501 1 A500 5 A501 EMERGENCY LIGHTING IN ACCORDANCE WITH OBC 3.2.7.3 SMOKE AND HEAT DETECTOR IN ACCORDANCE WITH OBC 3.2.4.12. EL EMERGENCY LIGHTING IN ACCORDANCE WITH OBC 3.2.7.3 SMOKE AND HEAT DETECTOR IN ACCORDANCE WITH OBC 3.2.4.12. EMERGENCY LIGHTING IN ACCORDANCE WITH OBC 3.2.7.3 EL EL SMOKE AND HEAT DETECTOR IN ACCORDANCE WITH OBC 3.2.4.12. FIRE DETECTOR IN ACCORDANCE WITH OBC 3.2.4.11. FIRE DETECTOR IN ACCORDANCE WITH OBC 3.2.4.11. SERVICE SHAFT TO BE SEPARATED FROM REMAINDER OF THE BUILDING W/ FIRE SEPARATION OF NOT CORRIDOR LESS THAN 1HR FRR OBC 3.6.2.1. ELEVATOR HOIST WAY TO BE SEPARATED FROM REMAINER OF THE BUILDING WITH FIRE SEPARATION OF 1.5HR FRR IN ACCORDANCE WITH OBC 3.5.3.1. FIRE DETECTOR IN ACCORDANCE WITH OBC 3.2.4.11. ELEVATOR HOIST WAY TO BE SEPARATED FROM REMAINER OF THE BUILDING WITH FIRE SEPARATION OF 1.5HR FRR IN ACCORDANCE WITH OBC 3.5.3.1. TURNING DIA. ø 1500 FIRE RATED GARBAGE CHUTE DOOR INTWA 2 INTWA INTWA INTWA 1 INTWA 2 EXWA EXWAEXWA EXWA 2 INTWA INTWA 2 EXWA INTWA 1 EXWA INTWA INTWA 2 INTWA 2 INTWA 2 EXWA 2 EXWA 2 ED.1 ED.1 ED.1 D.06.604.3 SERVICE 603 ELEV. 607 ELEV. 607.1 STORAGE 606 GARB. RM. 605.1 CHUTE 605 L600 CORRIDOR 604.1 L600 ELEV. LOBBY 604 INTWA RF 3 RF 2 RF 2 RF 1 RF 3 RF 3 RF 2 RF 3 RF 3 31.47 m 23 sec RF 2 RF 3 RF 3 RF 3 RF 3 TYP. ROOF DRAIN AND INSPECTION CHAMBER. COMMON GREEN ROOF AREA. TYP. ROOF DRAIN AND INSPECTION CHAMBER. COMMON GREEN ROOF AREA. TYP. ROOF DRAIN AND INSPECTION CHAMBER. COMMON GREEN ROOF AREA. TYP. ROOF DRAIN AND INSPECTION CHAMBER. COMMON GREEN ROOF AREA. PAWA 2 PAWA 2 PAWAPAWA 4 PAWA PAWA 2 D.06.604.3.1 TYP. LINEAR ROOF DRAIN.TYP. LINEAR ROOF DRAIN. 368 640 3009 473 408 408 3482 867 152 2000 419 651 3035 447 408 408 395 3087 640 31.47 m 23 sec 368 3874 408 408 3466 408 408 1668 2050 221 3216 221 2144 1574 408 408 3466 408 408 3874 368 408 408 4026 408 408 4750 40840840264084084669 THYSSENKRUPP SYNERGY SELF 2500 ELEVATOR. REFER TO PRODUCT SPECIFICATIONS. 408 408 368 640 1012 1997 473 408 408 3482 600 419 2000 419 651 845 2190 640 DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A222.1 L600 ENLARGED FLOOR PLAN PART 'B' AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 50 L600 ENLARGED FLOOR PLAN -PART B
FHC REF. REF.W/D W/D REF. PART 'C' 2.7 6.H 6.H 6.I 6.I 6.J 6.J 6.G 6.G 6.3 6.3 6.1 6.1 6.2 6.2 6.4 6.4 6.5 6.5 6.7 6.7 6.9 6.6 6.6 6.8 6.8 6.10 6.10 6.K 6.K 6.L 6.L 6.H16.G16.G2 3 A500 DOOR TO BE EQUIPPED W/ AUTOMATIC CLOSURE. DOOR AND CLOSURES TO BE EQUIPPED W/ 1.5H FRR MANUAL PULL STATION IN ACCORDANCE WITH OBC 3.2.4.18. FIRE HOSE CABINET IN ACCORDANCE WITH OBC 3.2.9.4. 1HR FRR FIRE SEPERATION OF DWELLING UNITS FROM REMAINDER OF BUILDING IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) PROVIDE SMOKE AND HEAT DETECTOR IN EXIT STAIR SHAFT IN ACCORDANCE WITH OBC 3.2.4.12. SMOKE AND HEAT DETECTOR IN ACCORDANCE WITH OBC 3.2.4.12. EMERGENCY LIGHTING IN ACCORDANCE WITH OBC 3.2.7.3 MPS EL L EXWA INTWA INTWA INTWA INTWA 1 D.06.604.4 D.06.607.6 D.06.607.5 D.06.608.6 D.06.604.5 D.06.608.5 D.06.604.6 D.06.610.3D.06.610.2D.06.604.7 ENT. LOBBY 608.1 HALLWAY 608.1.1 LIVING AREA 608.3 DINING AREA 608.4.1 KITCHEN 608.4 LAUNDRY STORAGE 608.5 POWDER RM. 608.6 STAIRS 608.2 LIVING AREA 607.3 DINIING AREA 607.4.1 KITCHEN 607.4 HALLWAY 607.1.1 ENT. LOBBY 607.1 POWDER RM. 607.6 LAUNDRY STORAGE 607.5 STAIRS 607.2 KITCHEN 610.4 DINING AREA 610.4.1 ENT. LOBBY 610.1 HALLWAY 610.1.1 STAIRS 610.6 LIVING AREA 610.5 LAUNDRY STORAGE 610.3 POWDER RM. 610.2 ENT. CLOSET ENT. CLOSET ENT. CLOSET STAIRS 'B' 609.1 RF 2 RF 1 RF 2 RF 1 RF RF RF RF RF 3 RF 3 RF RF RF 31.47 m 23 sec SA SA CMA KITCHEN MILLWORK. REFER TO MILLWORK SCHEDULE. PROVIDE (1) SMOKE ALARM C/W STROBE AND AUDIBLE IN COMMON AREA (TYP.) DWELLING UNIT NOTES: 1. DOORS TO BE LOCATED 100mm OFF OF INTERIOR WALL CORNERS UNO. 2. CLOSET DOORS TO BE CENTRED IN CLOSET WALLS UNO. PROVIDE (1) CARBON MONOXIDE ALARM IN EACH DWELLING UNIT (TYP.) 1HR FRR FIRE SEPARATION BETWEEN DWELLING UNITS AND OTHER AREAS IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) SA CMA PROVIDE (1) SMOKE ALARM C/W STROBE AND AUDIBLE IN COMMON AREA (TYP.) PROVIDE (1) CARBON MONOXIDE ALARM IN EACH DWELLING UNIT (TYP.) DWELLING UNIT NOTES: 1. DOORS TO BE LOCATED 100mm OFF OF INTERIOR WALL CORNERS UNO. 2. CLOSET DOORS TO BE CENTRED IN CLOSET WALLS UNO. SA KITCHEN MILLWORK. REFER TO MILLWORK SCHEDULE. 1HR FRR FIRE SEPARATION BETWEEN DWELLING UNITS AND OTHER AREAS IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) KITCHEN MILLWORK. REFER TO MILLWORK SCHEDULE. 1HR FRR FIRE SEPARATION BETWEEN DWELLING UNITS AND OTHER AREAS IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) SA CMA PROVIDE (1) SMOKE ALARM C/W STROBE AND AUDIBLE IN COMMON AREA (TYP.) PROVIDE (1) CARBON MONOXIDE ALARM IN EACH DWELLING UNIT (TYP.) DWELLING UNIT NOTES: 1. DOORS TO BE LOCATED 100mm OFF OF INTERIOR WALL CORNERS UNO. 2. CLOSET DOORS TO BE CENTRED IN CLOSET WALLS UNO. SA RF 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". BALCONY EXTENDED GARDEN FROM BALCONY TYP. ROOF DRAIN AND INSPECTION CHAMBER. TYP. ROOF DRAIN AND INSPECTION CHAMBER. EXTENDED GARDEN FROM BALCONY TYP. ROOF DRAIN AND INSPECTION CHAMBER. EXTENDED GARDEN FROM BALCONY PAWA PAWA 4 PAWA PAWA PAWA PAWA 4 PAWA PAWA TYP. LINEAR ROOF DRAIN. TYP. LINEAR ROOF DRAIN. 419163 139 3273 315 2565 968 353 1406 200 2000 200 1348 1289 2682 315 1682 315 1320 163 419 408 408 4434 368 1283 408 408 1716 1935 333 163 413 1807 315 2242 3383 98 419 333 4213 408 408 4497 419 163 1325 782 315 1065 2205 315 2233 98 419 1935 1907 408 408 1842 368 1283 408 408 1716 1935 343 98 2220 315 2217 575 477 1208 2035 200 3625 200 1307 1354 3172 325 1682 315 1355 163 419 TYP. ROOF DRAIN AND INSPECTION CHAMBER. 640 1012 1997 473 408 408 3482 600 419 2000 419 651 845 2190 447 408 408 3482 640 DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A222.2 L600 ENLARGED FLOOR PLAN PART 'C' AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 50 L600 ENLARGED FLOOR PLAN -PART C
PART 'A' 2.7 2.A 2.E 6.C 6.D 6.D 6.E 6.E 6.B 6.B 6.A 6.3 6.3 6.1 6.1 6.2 6.2 6.4 6.4 6.5 6.5 6.7 6.7 6.9 6.6 6.6 6.8 6.8 6.10 6.10 6.F 6.F 6.E1 6.F1 6.F2 4 A501 1 A600 BEDROOM 705.5 MASTER BEDROOM 702.3 BEDROOM 2 702.4 BEDROOM 1 702.5 BATHROOM 702.2 ENSUITE 702.3.2 BEDROOM 1 703.3 BEDROOM 2 730.2 MASTER BEDROOM 703.4 ENSUITE 703.4.2 BATHROOM 703.5 HALLWAY 703.1.1 STAIRS 703.1 STAIRS 705.1 HALLWAY 705.1.1 HALLWAY 702.1.1 STAIRS 702.1 MASTER BEDROOM 705.3 BEDROOM 2 705.4 WIC 705.3.1 ENSUITE 705.3.2 BATHROOM 705.2 WIC 702.3.1 WIC 703.4.1 SA SA CMA DWELLING UNIT NOTES: 1. DOORS TO BE LOCATED 100mm OFF OF INTERIOR WALL CORNERS UNLESS NOTED OTHERWISE. 2. CLOSET DOORS TO BE CENTRED IN CLOSET WALLS UNLESS NOTED OTHERWISE. SLEEPING ROOMS WITHIN DWELLING UNITS TO BE EQUIPPED WITH SMOKE ALARMS C/W STROBE LIGHT AND SOUND. PROVIDE (1) SMOKE ALARM C/W STROBE AND AUDIBLE IN COMMON AREA (TYP.) 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". BALCONY SA SA 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". BALCONY SA SA SA SA CMA 1HR FRR FIRE SEPARATION BETWEEN DWELLING UNITS IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) SLEEPING ROOMS WITHIN DWELLING UNITS TO BE EQUIPPED WITH SMOKE ALARMS C/W STROBE LIGHT AND SOUND. PROVIDE (1) SMOKE ALARM C/W STROBE AND AUDIBLE IN COMMON AREA (TYP.) DWELLING UNIT NOTES: 1. DOORS TO BE LOCATED 100mm OFF OF INTERIOR WALL CORNERS UNLESS NOTED OTHERWISE. 2. CLOSET DOORS TO BE CENTRED IN CLOSET WALLS UNLESS NOTED OTHERWISE. 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". BALCONY SA SA SA SA CMA SLEEPING ROOMS WITHIN DWELLING UNITS TO BE EQUIPPED WITH SMOKE ALARMS C/W STROBE LIGHT AND SOUND. PROVIDE (1) SMOKE ALARM C/W STROBE AND AUDIBLE IN COMMON AREA (TYP.) DWELLING UNIT NOTES: 1. DOORS TO BE LOCATED 100mm OFF OF INTERIOR WALL CORNERS UNLESS NOTED OTHERWISE. 2. CLOSET DOORS TO BE CENTRED IN CLOSET WALLS UNLESS NOTED OTHERWISE. PAWA 2 PAWA PAWA 3 PAWA 3 PAWA PAWA 2 PAWA 3 PAWA PAWAPAWA 419 163 1389 718 315 622 1628 1019 223 260500 1499 163 419 2000 419 1916 1818 1170 651 1360 678 1997 65 200 3625 200 764 2100 287 115 366 1266 1512 326 552 1858 419 1975 4192140291139463064062828815457021634192089 419 173 3095 307 315 1268 654 562 1049 338 639 1645 98 200 118 1085 288 1730 791 866 1330 577 315 292 1390 315 1272 163 419 200 2189 192 123 996 148 167 1959 315 2220 98 419 OPEN TO BELOW DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A223 L700 ENLARGED FLOOR PLAN PART 'A' AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 50 L700 ENLARGED FLOOR PLAN -PART A
PART 'B' 6.3 6.3 6.1 6.1 6.2 6.2 6.4 6.4 6 A501 5 A501 RF 3 RF 3 PAWA PAWA PAWA 2 PAWA 2 EMERGENCY LIGHTING IN ACCORDANCE WITH OBC 3.2.7.3 EL SMOKE AND HEAT DETECTOR IN ACCORDANCE WITH OBC 3.2.4.12. FIRE DETECTOR IN ACCORDANCE WITH OBC 3.2.4.11. FIRE DETECTOR IN ACCORDANCE WITH OBC 3.2.4.11. SERVICE SHAFT TO BE SEPARATED FROM REMAINDER OF THE BUILDING W/ A FIRE SEPARATION OF NOT CORRIDOR LESS THAN 1HR FRR OBC 3.6.2.1. ELEVATOR HOIST WAY TO BE SEPARATED FROM REMAINER OF THE BUILDING WITH FIRE SEPARATION OF 1.5HR FRR IN ACCORDANCE WITH OBC 3.5.3.1. FIRE DETECTOR IN ACCORDANCE WITH OBC 3.2.4.11. ELEVATOR HOIST WAY TO BE SEPARATED FROM REMAINER OF THE BUILDING WITH FIRE SEPARATION OF 1.5HR FRR IN ACCORDANCE WITH OBC 3.5.3.1. TURNING DIA. ø 1500 INTWA 2 INTWA 2 INTWA 2 INTWA 1 INTWA 2 INTWA INTWA 2 EXWA 2 INTWA 1 INTWA INTWA 2 INTWA 2 INTWA 2 INTWA VENT GARBAGE CHUTE THROUGH ROOF REFER TO ROOF PLAN FOR LOCATION AND PIPE SIZE. L600 CORRIDOR 705.6 L600 ELEV. LOBBY 705.8 WC-3 WC-3 EXWA 2EXWA RAH RAH THYSSENKRUPP SYNERGY SELF 2500 ELEVATOR. REFER TO PRODUCT SPECIFICATIONS. 9412 2838 DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A223.1 L700 ENLARGED FLOOR PLAN PART 'B' AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 50 L700 ENLARGED FLOOR PLAN -PART B
PART 'C' 2.7 2.P 2.P 6.H 6.H 6.I 6.I 6.J 6.J 6.G 6.G 6.3 6.3 6.1 6.1 6.2 6.2 6.4 6.4 6.5 6.5 6.7 6.7 6.9 6.6 6.6 6.8 6.8 6.10 6.10 6.K 6.K 6.L 6.L 6.H16.G16.G2 3 A500 BEDROOM 1 708.2 MASTER BEDROOM 706.4 BEDROOM 2 706.3 BEDROOM 1 706.2 BATHROOM 706.5 ENSUITE 706.4.2 BEDROOM 1 707.4 BEDROOM 2 707.5 MASTER BEDROOM 707.3 ENSUITE 707.3.2 BATHROOM 707.2 HALLWAY 707.1.1 STAIRS 707.1 STAIRS 708.1 HALLWAY 708.1.1 HALLWAY 706.1.1 STAIRS 706.1 MASTER BEDROOM 708.4 BEDROOM 2 708.3 WIC 708.4.1 ENSUITE 708.4.2 BATHROOM 708.5 WIC 706.4.1 WIC 707.3.1 DWELLING UNIT NOTES: 1. DOORS TO BE LOCATED 100mm OFF OF INTERIOR WALL CORNERS UNLESS NOTED OTHERWISE. 2. CLOSET DOORS TO BE CENTRED IN CLOSET WALLS UNLESS NOTED OTHERWISE. DWELLING UNIT NOTES: 1. DOORS TO BE LOCATED 100mm OFF OF INTERIOR WALL CORNERS UNLESS NOTED OTHERWISE. 2. CLOSET DOORS TO BE CENTRED IN CLOSET WALLS UNLESS NOTED OTHERWISE. DWELLING UNIT NOTES: 1. DOORS TO BE LOCATED 100mm OFF OF INTERIOR WALL CORNERS UNLESS NOTED OTHERWISE. 2. CLOSET DOORS TO BE CENTRED IN CLOSET WALLS UNLESS NOTED OTHERWISE. SLEEPING ROOMS WITHIN DWELLING UNITS TO BE EQUIPPED WITH SMOKE ALARMS C/W STROBE LIGHT AND SOUND. PROVIDE (1) SMOKE ALARM C/W STROBE AND AUDIBLE IN COMMON AREA (TYP.) 1HR FRR FIRE SEPARATION BETWEEN DWELLING UNITS IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". BALCONY 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". BALCONY 1HR FRR FIRE SEPARATION BETWEEN DWELLING UNITS IN ACCORDANCE WITH OBC 3.3.4.2. (TYP.) SLEEPING ROOMS WITHIN DWELLING UNITS TO BE EQUIPPED WITH SMOKE ALARMS C/W STROBE LIGHT AND SOUND. PROVIDE (1) SMOKE ALARM C/W STROBE AND AUDIBLE IN COMMON AREA (TYP.) 1070 HIGH GUARD C/W GLASS CONFORMING TO OBC 3.1.20.1 AND OBC SB 13 "GLASS IN GUARDS". BALCONY SLEEPING ROOMS WITHIN DWELLING UNITS TO BE EQUIPPED WITH SMOKE ALARMS C/W STROBE LIGHT AND SOUND. PROVIDE (1) SMOKE ALARM C/W STROBE AND AUDIBLE IN COMMON AREA (TYP.) SA SA SA SA SASA SA SA SA SA SA SA CMA CMA CMA PAWA 2 PAWA PAWA 3 PAWA 3 PAWA 3 PAWA 2 PAWA PAWA PAWA PAWA 3 OPEN TO BELOW 2089 419 163 702 1518 315 628 640 630 1394 289 1979 163 419 419 163 2220 315 1959 192 123 996 148 167 2124 200 2062 678 1360 666 1132 745 1145 1787 98 419 2000 394 1858 552 326 1512 1243 389 115 2388 764 200 3625 200 419 146 1337 1730 253 329 602 1330 1657 1705 313 1085 2449 200 419 163 3105 307 315 1268 596 620 1025 339 662 1743 200 419 163 2107 315 622 1686 962 315 168494 1655 DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A223.2 L700 ENLARGED FLOOR PLAN PART 'C' AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 50 L700 ENLARGED FLOOR PLAN -PART C
L100 0 L200 5000 L300 500 9000 L400 13000 L500 17000 L600 21000 L700 24600 ROOF 28200 HIGH ROOF 29864.95 2 A500 6 A501 1 A500 3 A500 1 A600 5 m 4 m 4 m 4 m 4 m 3.6 m 3.6 m 1.66 m 1200 3900 1100 500 2200 1300 500 2200 1800 2200 1800 2200 1300 1724 2200 1000 2700 800 A AAA B B AAA AAA AAA A A A A A BB A A A A A A A A A A BB B B ABB A A A A A B B A A B CCCCC CCCCC B B 1200 3900 1100 2700 1300 500 2200 1300 500 2200 1300 500 2200 1300 500 2200 1000 2700 800 BUILDING SIGNAGE -SEE SHOP DRAWINGS BARRIER FREE ENTRANCE IN ACCORDANCE WITH OBC 3.8.3.3. (TYP.) APPROXIMATE FINISHED GRADE MIN. 2% SLOPE AWAY FROM THE BUILDING BUILDING SIGNAGE -SEE SHOP DRAWINGS DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A400 BUILDING ELEVATIONS AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 125 EAST ELEVATION BUILDING FINISHES A ALUMAX PRE-FINISHED IVORY ACM PANEL SYSTEM B ALUMAX PRE-FINISHED PEARL BLACK ACM PANEL SYSTEM C ARRISCRAFT: ARCHITECTURAL BRICK CLADDING GLAZING
L100 0 L200 5000 L300 500 9000 L400 13000 L500 17000 L600 21000 L700 24600 ROOF 28200 HIGH ROOF 29864.95 2 A500 6 A501 1 A500 3 A500 1 A600 1.66 m 3.6 m 3.6 m 4 m 4 m 4 m 4 m 5 m A A A A A A A A A A B A AB B A A A A A B B B B B CCCCCCCC CC B B B B B B B B A A A A A AA A A A A 1665 800 2700 100 900 2200 500 13002200 500 1300 2200 500 1300 2200 500 1300 2200 500 1100 3900 367 800 2700 100 900 2200500 1300 2200 500 1300 2200 500 1300 2200 500 1300 2200 500 1100 3900 1200 BUILDING SIGNAGE -SEE SHOP DRAWINGS BARRIER FREE ENTRANCE IN ACCORDANCE WITH OBC 3.8.3.3. (TYP.) BARRIER FREE ENTRANCE IN ACCORDANCE WITH OBC 3.8.3.3. (TYP.) APPROXIMATE FINISHED GRADE MIN. 2% SLOPE AWAY FROM THE BUILDING 3 DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A401 BUILDING ELEVATIONS AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 125 WEST ELEVATION BUILDING FINISHES A ALUMAX PRE-FINISHED IVORY ACM PANEL SYSTEM B ALUMAX PRE-FINISHED PEARL BLACK ACM PANEL SYSTEM C ARRISCRAFT: ARCHITECTURAL BRICK CLADDING GLAZING
L100 0 L200 5000 L300 500 9000 L400 13000 L500 17000 L600 21000 L700 24600 ROOF 28200 HIGH ROOF 29864.95 4 A501 5 A501 1.66 m 3.6 m 3.6 m 4 m 4 m 4 m 4 m 5 m BARRIER FREE ENTRANCE IN ACCORDANCE WITH OBC 3.8.3.3. (TYP.) APPROXIMATE FINISHED GRADE MIN. 2% SLOPE AWAY FROM THE BUILDING C B A CCCC A A A B A A A A A A A AB B B B B B A A A AB B B AA A B B 1665 800 2700 100 900 2700 1300 2200 500 1300 2200 500 1300 2200 500 1300 1950250 500 1100 900 3000 S L O P E 5. 0° S L O P E 5 0 L100 0 L200 5000 L300 500 9000 L400 13000 L500 17000 L600 21000 L700 24600 ROOF 28200 1.66 m 3.6 m 3.6 m 4 m 4 m 4 m 4 m 5 m HIGH ROOF 29864.95 4 A501 5 A501 BARRIER FREE ENTRANCE IN ACCORDANCE WITH OBC 3.8.3.3. (TYP.) APPROXIMATE FINISHED GRADE MIN. 2% SLOPE AWAY FROM THE BUILDING A A A A A A A A A A A A A A A A AA AA BB B B B B B B B B B B B B BB BB CCCCC 1665 800 2700 100 900 2700 1300 2200 500 1300 2200 500 1300 2200 500 1300 1950250 500 1100 900 3000 1200 3900110075097417625141210279012102790121019768145501000205033862141665 2230 2114 1195 S L O P E 5 0 S L O P E 5 0 DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A402 BUILDING ELEVATIONS AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 125 NORTH ELEVATION 1 125 SOUTH ELEVATION BUILDING FINISHES A ALUMAX PRE-FINISHED IVORY ACM PANEL SYSTEM B ALUMAX PRE-FINISHED PEARL BLACK ACM PANEL SYSTEM C ARRISCRAFT: ARCHITECTURAL BRICK CLADDING GLAZING
DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION L100 0 L200 5000 L300 500 9000 L400 13000 L500 17000 L600 21000 L700 24600 ROOF 28200 T/O FOOTING 1200 1.6 2.7 HIGH ROOF 29864.95 6.7 C.I.P. REINFORCED CONCRETE FOUNDATION WALL REFER TO STRUCTURAL DRAWINGS PRE FINISHED ALUMAX ACM PARAPET BEYOND BLUE METAL SUSPENDED CEILING PANEL SHAPED BEYOND CONCRETE SIDE WALK SLOPES AWAY FROM WALL AT 2% SF SF FL FL BLUE METAL SUSPENDED CEILING PANEL S SHAPED BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S ISOKORB THERMAL BREAK BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S ISOKORB THERMAL BREAK BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S ISOKORB THERMAL BREAK BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S ISOKORB THERMAL BREAK BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S EXWA 2 PAWA 3 EXWA 2BEYOND EXWA PAWA EXWABEYOND EXWA 2 PAWA 3 EXWA 2BEYOND SF SF ISOKORB THERMAL BREAK PAWA 4 RF FL 5 CLTFL FL FL FL FL RFRF EXWA 2 EXWA 2BEYOND BEYO D EXWA 2 EXWA 2 W5 W3 SF RF RF RF EXWA 4 1.66 m 3.6 m 3.6 m 4 m 4 m 4 m 4 m 5 m 1.2 m EXWA 2 EXWA 2BEYOND 520 850 350 3211 889 600 300 3058 642 300 3058 642 300 3058 642 300 2756 644 300 300 2828 458 314 695 304 439 3183 KITCHEN BEDROOM 2 MASTER BEDROOM WIC FOOD STORE CURTAIN WALL REFER TO CURTAIN WALL SCHEDULE PAWA 1 575 200 750 300 150 3000 900 1100 750 974 1762 514 209 3791 209 3791 209 958 617 275 300 214 1976 960 250 300 214 2276 960 250 300 214 2276 960 250 300 3725 275 600 4100 350 850 806 1381 2700 100 900 2200 500 EXWA 2BEYOND BALCONY BEYOND BALCONY BEYOND BALCONY BEYOND FTG EXCOL 3200 3200 775mm 520mm FOUNDATION SLAB SFDN 1SFDN 2 FL 1 2 A701 4 A701 119517681195 GRADE 253.85 CONTEXT MASSING INDUSTRIAL 257.85 L100 0 L200 5000 L300 500 9000 L400 13000 L500 17000 L600 21000 L700 24600 T/O FOOTING 1200 1.11.2 5 A702 C.I.P. REINFORCED CONCRETE FOUNDATION WALL REFER TO STRUCTURAL DRAWINGS PRE FINISHED ALUMAX ACM PARAPET BEYOND BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S 600x600 EXTERIOR COLUMN REFER STRUCTURAL DRAWINGS CONCRETE SIDE WALK SLOPES AWAY FROM WALL AT 2% BEYOND 3.6 m 4 m 4 m 4 m 4 m 5 m 1.2 m 425 775 750 300 150 3900 1100 750 975 500 2200 786 214 300 250 250 2200 786 214 300 250 250 2200 786 214 300 250250 2200 700 300 300 550 EXWA 1EXWA 4EXWAEXWA 4 400x400 INTERIOR COLUMN FL 1 PAWA 2 RF RF FL FL W1 W1 W1 W1 EXWA FL 3 PAWA 3 EXWA 6 EXWA FL PAWA EXWA EXWA FL PAWA EXWA EXWA PAWARFRF 2 ISOKORB THERMAL BREAK BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S FL ISOKORB THERMAL BREAK BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S FL ISOKORB THERMAL BREAK BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S FL MEDIA ROOM TAVERN TAVERN BEDROOM BEDROOM STAINLESS STEEL CORROGATED DOVETAIL BRICKTIE @ EVERY 200mm VERT. SPACED NOTE: FLOORS TO BE FIRE SEPARATIONS WITH MIN. 2HR FRR IN ACCORDANCE WITH OBC 3.1.3.1. (TYP.) ISOKORB THERMAL BREAK BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S EXWA 6 FTG INTCOL 5200 5200 1200mm FTG EXCOL 3200 3200 775mm 300 600 BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S NOTE: TAVERN INTERIOR FINISHES TO BE COMPLETE BY INTERIOR DESIGNER CONFRIM FINISHED WITH ARCHITECT SF 2 SF 2 SF 2 L600 CORRIDOR L300 CORRIDOR L200 CORRIDOR STAIR 'A' CORRIDOR L400 CORRIDOR L500 CORRIDOR RF 3 RF 3 FL EXWA PAWA INTWA 1 INTWA 1 INTWA 1 INTWA 1 INTWA 1 FL 2 3 A701 L100 0 L200 5000 L300 500 9000 L400 13000 L500 17000 L600 21000 L700 24600 ROOF 28200 T/O FOOTING 1200 1.6 1.4 HIGH ROOF 29864.95 6.5 6.10 1 A700 1 A701 4 A702 C.I.P. REINFORCED CONCRETE FOUNDATION WALL REFER TO STRUCTURAL DRAWINGS 1.66 m 3.6 m 3.6 m 4 m 4 m 4 m 4 m 5 m 1.2 m 520 850 350 3000 458 642 900 3058 642 300 3058 642 300 3058 642 300 2758 642 300 300 342 250592 300 514 486 2200 500 514 786 2200 500 514 786 2200 500 514 786 2200 1400 4100 CURTAIN WALL PARAPET 300 150 3000 900 1100 473 316 VELUX GLAZED INSULATED MODULAR SKYLIGHT BEYONDEXWA CURTAIN WALL REFER TO CURTAIN WALL SCHEDULE CONCRETE SIDE WALK SLOPES AWAY FROM WALL AT 2% BEYONDEXWA EXWA 2 W1 SF EXWA 2 W1 SF PAWA 3 INTWA 7 W1 SF EXWA 2 W1 SF PAWA 3 PAWA 3 PAWA 4 PAWA 2 RF 1RF FL 3 FL 3 FL 3 FL 2 BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S ISOKORB THERMAL BREAK BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S ISOKORB THERMAL BREAK BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S ISOKORB THERMAL BREAK BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S SECONDARY VEST. CONDO ENTRANCE LOBBY MECH. ELEC. ROOM LIVING AREA LIVING AREA LIVING AREA FL 1 SFDN FTNG LB C.I.P 2000 X 520mm SFDN FTG EXCOL 3200 x 3200 x 775mm NOTE: FLOORS TO BE FIRE SEPARATIONS WITH MIN. 2HR FRR IN ACCORDANCE WITH OBC 3.1.3.1. (TYP.) 300 600 CONCRETE UPSTAND FOR SKYLIGHT INSERTS L600 CORRIDOR L300 CORRIDOR L200 CORRIDOR WC-4 60050031003300300 275 491 RF W SL PAWA EXWA INTWA 1 INTWA 1 INTWA 1 INTWA 1 L400 CORRIDOR L500 CORRIDOR DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A500 CONSTRUCTION SECTIONS AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 75A200 SEC03 -EXTERIOR WALL AT BALCONIES3 75A200 SEC02 -EXTERIOR WALL AT WINDOWS2 1 75A200 SEC01 -EXTERIOR WALL THROUGH FRONT ENTRANCE WITH LOBBY1

CHUTE SEE SHOP DRAWINGS FOR MANUFACTURERS ROOF CONNECTION DETAIL

NOTE:

CHUTE

AREA OF THE CHUTE IN ACCORDANCE WITH OBC 3.6.3.

CHUTE TO EXTEND NOT LESS THAN 1000mm ABOVE FINISHED ROOF LEVEL IN ACCORDANCE WITH OBC 3.6.3.3.(3)

NOTE:

NOTE: REFUSE CHUTE SHALL BE IMPERVIOUS TO MIOSTURE, HAVE A SMOOTH INTERNAL SURFACE, BE CORROSION RESISTANT

NOTE:

DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM CK BLVD BUILDING LOCATION L100 0 L200 5000 L300 500 9000 L400 13000 L500 17000 L600 21000 L700 24600 ROOF 28200 T/O FOOTING 1200 1.G 1.H 3.6 m 3.6 m 4 m 4 m 4 m 4 m 5 m 1.2 m FL FL FL FL FL 1 FL RF 3 RFRF 275 300 3849 3051 600 349 3051 300 649 3051 300 649 3051 300 649 3051 900 1049 3051 350 850 680 520 ED.1 ED.1 ED.1 ED.1 ED.1 ED.1 FL FL FL FL FL EXWA 2 PAWA 5 INTWA INTWA 2 INTWA 2 BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S INTWA 2 INTWA 2 INTWA 2 INTWA 2 INTWA 2 INTWA 2 INTWA 2 INTWA 520mm FOUNDATION SLAB 641 SFDN 1SFDN CONDO ENTRANCE LOBBYCONDO LOCKER MEDIA ROOM L200 ELEV. LOBBY L300 ELEV. LOBBY L600 ELEV. LOBBY KITCHEN KITCHEN KITCHEN L400 ELEV. LOBBY L500 ELEV. LOBBY 550 275 7200 600 3400 300 3700 300 3700 300 3700 900 4100 ELE. PIT DEPTH 1650 mm MIN. 1880 NOTE: ELEVATOR HOISTWAY TO BE SEPERATED FROM REMAINDER OF THE BUILDING WITH A FIRE SEPARATION OF 1.5HR FRR IN ACCORDANCE WITH OBC 3.5.3.1. NOTE: FLOORS TO BE FIRE SEPARATIONS WITH MIN. 2HR FRR IN ACCORDANCE WITH OBC 3.1.3.1. (TYP.) NOTE: FIRE & HEAT DETECTOR IN ACCORDANCE WITH OBC 3.2.4.11. (TYP.) ELEV. 2 ELEV. 2 ELEV. 2 ELEV. 2 ELEV. 2 ELEV. 2 2.05 m L100 0 L200 5000 L300 500 9000 L400 13000 L500 17000 L600 21000 L700 24600 ROOF 28200 T/O FOOTING 1200 1.A2.A HIGH ROOF 29864.95 1.66 m 3.6 m 3.6 m 4 m 4 m 4 m 4 m 5 m 1.2 m 933 732 800 629 2171 314 1786 1500 600 3400 300 3700 300 3700 300 642 958 2100 900 642 3458 350 850 520 255 369 568 595 2700 100 894 2200 531 275 300 214486 2200 500 1300 2200 500 1300 2200 500 1300 2200 500 1100 3900 150 300 750 775 FTNG LB C.I.P 2000 X 520mm FTG EXCOL 3200 x 3200 x 775mm SFDN 2 FL 1 EXWA 4 W1 W1 W1 W1 FL 4 FL 3 FL 3 FL 3 2114 WC-1 EXWA 2 EXWA 2 EXWA 2 EXWA 2 EXWA 4 EXWA 1 C.I.P. REINFORCED CONCRETE FOUNDATION WALL REFER TO STRUCTURAL DRAWINGS PRE FINISHED ALUMAX ACM PARAPET BEYOND BEYOND CONCRETE SIDE WALK SLOPES AWAY FROM WALL AT 2% BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S WC-2 W4 W1 D.06.600.1 D.06.710.2 W6 RF 4 EXWA 2 PAWA 4 ? BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S INTWA 7 CLTFL 1082 1785 WC-1 SF 1 KITCHEN HALLWAY BEDROOM ENT. LOBBY TAVERN STAIRS HALLWAY STAINLESS STEEL CORROGATED DOVETAIL BRICKTIE @ EVERY 200mm VERT. SPACED NOTE: FLOORS TO BE FIRE SEPARATIONS WITH MIN. 2HR FRR IN ACCORDANCE WITH OBC 3.1.3.1. (TYP.) NOTE: TAVERN INTERIOR FINISHES TO BE COMPLETE BY INTERIOR DESIGNER CONFRIM FINISHED WITH ARCHITECT SF 1 KITCHEN KITCHEN HALLWAY HALLWAY L100 0 L200 5000 L300 500 9000 L400 13000 L500 17000 L600 21000 L700 24600 ROOF 28200 T/O FOOTING 1200 6.3 D.04.404.04D.05.504.04D.06.604.3.1 D.03.304.4 D.02.204.4 GCH 1 L600 ELEV. LOBBY L500 ELEV. LOBBY L400 ELEV. LOBBY L300 ELEV. LOBBY L200 ELEV. LOBBY GARB. RM. GARB. RM. GARB. RM. GARB. RM. GARB. RM. GAR. RM. MAIL ROOM CHUTE CHUTE CHUTE CHUTE CHUTE CHUTE 3.6 m 3.6 m 4 m 4 m 4 m 4 m 5 m 1.2 m 1565 275 300 6900 600 3400 300 3700 300 3700 300 3700 900 1990 2110 350 850 520 4725 906 721 548 600 2131 721 548 300 2431 721 548 300 2431 721 548 300 2431 721 548 900 1420 2680 D.01.02.03 NOTE: REFUSE SHAFT SHALL BE SEPARATED FROM REMAINDER OF THE BUILDING BY A FIRE SEPARATION HAVING A FRR OF 1HR (min.) IN ACCORDANCE WITH OBC 3.6.3.1 NOTE: FLOORS TO BE FIRE SEPARATIONS WITH MIN. 2HR FRR IN ACCORDANCE WITH OBC 3.1.3.1. (TYP.)
SPRINKLERS SHALL BE INSTALLED AT THE TOP OF EACH LINEN OR REFUSE CHUTE, AT ALTENATE FLOOR LEVELSAND IN THE ROOM OR BIN THE CHUTE DISCHARGES IN ACCORDANCE WITH OBC 3.6.3.3.(6)
REFUSE CHUTE DOORS TO BE EQUIPPED WITH CLOSURES AND BE FIRE RATED IN ACCORDANCE WITH OBC
REFUSE
TO BE EQUIPPED WITH VENT WITH AN AREA NOT LESS THAN THE CROSS SECTIONAL
REFUSE
REFUSE
MIN.1000
AND BE CONSTRUCTED A NON COMBUSTIBLE MATERIAL IN ACCORDANCE WITH OBC 3.6.3.3.(1) (TYP.) RF 3 RF FASTEN REFUSE CHUTE TO C.I.P. CONC. WALL IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS NOTE: ROOM THAT CHUTE DISCHARGES INTO SHALL BE SEPARATED FROM REMAINDER OF THE BUILDING WITH A FIRE SEPERATION HAVING A FRR NOT LESS THAN 1HR IN ACCORDANCE WITH OBC 3.6.3.3.(7) C.I.P. CONCRETE SLAB ON GRADE NOT REQUIRED TO HAVE FIRE RESISTANCE RATING IN ACCORDANCE WITH OBC 3.1.3.1 520mm FOUNDATION SLAB SFDNSFDN FL 1 FL 2 FL 3 FL 3 FL 3 FL 5 BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S BLUE METAL LOAD BEARING CEILING SYSTEM W/ 13mm GYPSUM BOARD U/S DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A501 CONSTRUCTION SECTIONS AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 75A200 SEC05 -FULL HEIGHT ELEVATOR SECTION WITH LOBBY AND PIT5 1 75A200 SEC04 -EXTERIOR WALL AT END WALL4 1 75A200 SEC06 -GARBAGE CHUTE INTERIOR SECTION6
FHC UP 14 13 12 11 10 28 27 26 25 24 23 22 21 20 19 18 17 16 15 FHC UP 12 11 10 23 22 21 20 19 18 17 16 15 14 13 DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION L100 0 L200 5000 L300 500 9000 L400 13000 L500 17000 L600 21000 ROOF 28200 T/O FOOTING 1200 1.51.4 HIGH ROOF 29864.95 1302 363 7200 600 1225 R.O.2175 300 1525 R.O.2175 300 1525 R.O.2175 300 1525 R.O.2175 900 1925 R.O.2175 350 850 520 600 300mm + TREAD DEPTH 590 RUN 290 RISE179 STEEL CLOSED STRINGER STAIR HANDRAIL HT. 920 INSTALL HANDRAIL 920mm ABOVE TREAD NOSINGS IN ACCORDANCE WITH OBC 3.4.6.5.(4)(5) (TYP.) SPRINKLER PROTECTED GLAZED WALL ASSEMBLY IN ACCORDANCE WITH OBC 3.1.18.(1) HEADROOM CLEARENCE MIN. 2100mm, PROVIDED2200 PROVIDE A MINIMUM CLEARANCE OF 50mm BETWEEN HANDRAIL AND ANY SURFACE IN ACCORDANCE WITH OBC 3.4.6.5.(11) 40Ø METAL HANDRAIL FASTENED TO C.I.P. CONCRETE WALL c/w PAINT 300mm + TREAD DEPTH 590 300mm + TREAD DEPTH 590 HANDRAIL TO CONTINUE ON SLOPE FOR DEPTH OF ONE TREAD BEYOND BOTTOM RISER AND FMVOLLOWED BY A 300 (MIN.) HORIZONTAL EXTENSION IN ACCORDANCE WITH OBC 3.4.6.5.(10) 11 RISERS @ 178.5mm 1913 12 RISERS @ 174mm 2087 11 RISERS @ 178.5mm 1913 12 RISERS @ 174mm 2087 11 RISERS @ 178.5mm 1913 12 RISERS @ 174mm 2087 11 RISERS @ 178.5mm 1913 12 RISERS @ 174mm 2087 14 RISERS @ 178.5mm 2500 14 RISERS @ 178.5mm 2500 (1) HANDRAIL TO BE CONTINUOUS THROUGHOUT ITS ENTIRE LENGTH IN ACCORDANCE WITH OBC 3.4.6.5. (TYP.) 300mm + TREAD DEPTH 590 300mm + TREAD DEPTH 590 300 40Ø METAL HANDRAIL FASTENED TO C.I.P. CONCRETE WALL c/w PAINT (1) HANDRAIL TO BE CONTINUOUS THROUGHOUT ITS ENTIRE LENGTH IN ACCORDANCE WITH OBC 3.4.6.5. (TYP.) 40Ø METAL HANDRAIL FASTENED TO C.I.P. CONCRETE WALL c/w PAINT (1) HANDRAIL TO BE CONTINUOUS THROUGHOUT ITS ENTIRE LENGTH IN ACCORDANCE WITH OBC 3.4.6.5. (TYP.) 40Ø METAL HANDRAIL FASTENED TO C.I.P. CONCRETE WALL c/w PAINT (1) HANDRAIL TO BE CONTINUOUS THROUGHOUT ITS ENTIRE LENGTH IN ACCORDANCE WITH OBC 3.4.6.5. (TYP.) SPRINKLER PROTECTED GLAZED WALL ASSEMBLY IN ACCORDANCE WITH OBC 3.1.18.(1) G U A R D R A L H T 1070 HANDRAIL HT. 920 300 HANDRAIL HT. 920GUARDRAIL HT. 1070 HANDRAIL HT. 920GUARDRAIL HT. 1070 HANDRAIL HT. 920GUARDRAIL HT. 1070 300 GUARDRAIL HT. 1070 HANDRAIL HT. 920 300 300 1070 1.66 m 7.2 m 4 m 4 m 4 m 4 m 5 m 1.2 m EL MANUAL PULL STATION TO INSTALLED NEAR REQUIRED EXITS IN ACCORDANCE WITH OBC 3.2.4.18. HOSE STATION EQUIPPED WITH FIRE EXTINGUISHER TO BE LOCATED WITHIN 5m OF EXIT IN ACCORDANCE WITH OBC 3.2.9.4. L300 CORRIDOR L200 CORRIDOR STAIR 'A' CORRIDOR STAIR 'A' STAIR 'A' STAIR 'A' L600 CORRIDOR SMOKE AND HEAT DETECTOR TO BE INSTALLED IN EACH EXIT STAIR SHAFT IN ACCORDANCE WITH OBC 3.2.4.12. (TYP.) HOSE STATION EQUIPPED WITH FIRE EXTINGUISHER TO BE LOCATED WITHIN 5m OF EXIT IN ACCORDANCE WITH OBC 3.2.9.4. SMOKE AND HEAT DETECTOR TO BE INSTALLED IN EACH EXIT STAIR SHAFT IN ACCORDANCE WITH OBC 3.2.4.12. (TYP.) EXIT EXIT SIGNAGE TO BE INSTALLED ABOVE/ADJACENT TO EXIT DOORS IN ACCORDANCE WITH OBC 3.4.5.1 L500 CORRIDOR L400 CORRIDOR STAIR 'A' STAIR 'A' STAIR 'A' 520mm FOUNDATION SLAB SFDN 1SFDN 1 FL FL FL FL FL FL OFFICE RF 1RF DOUBLE HEADED EMERGENCY LIGHTS IN ALL EXITS IN ACCORDANCE WITH OBC 3.2.7.3. (TYP.) MANUAL PULL STATION TO INSTALLED NEAR REQUIRED EXITS IN ACCORDANCE WITH OBC 3.2.4.18. HOSE STATION EQUIPPED WITH FIRE EXTINGUISHER TO BE LOCATED WITHIN 5m OF EXIT IN ACCORDANCE WITH OBC 3.2.9.4. SMOKE AND HEAT DETECTOR TO BE INSTALLED IN EACH EXIT STAIR SHAFT IN ACCORDANCE WITH OBC 3.2.4.12. (TYP.) EXIT SIGNAGE TO BE INSTALLED ABOVE/ADJACENT TO EXIT DOORS IN ACCORDANCE WITH OBC 3.4.5.1 DOUBLE HEADED EMERGENCY LIGHTS IN ALL EXITS IN ACCORDANCE WITH OBC 3.2.7.3. (TYP.) EXIT EXIT EXIT EXIT 5 A600 1.B 1.5 1.4 1.C 1 A600 STAIR 'A' 110 590 290 13 + 1 TREADS @ 280 3770 LANDING DEPTH1550 14 TREADS @ 290 4060 MIN.7501018 362 LANDING DEPTH1960 MPS EL MANUAL PULL STATION TO INSTALLED NEAR REQUIRED EXITS IN ACCORDANCE WITH OBC 3.2.4.18 EXIT MIN. 600 MIN. 300 362 3463 362 TACTILE SURFACE SHALL BE INSTALLED AT LEADING EDGE OF THE LANDING WHERE DOORWAY OPENS ONTO STAIRS AND AT THE TOP OF STAIRS IN ACCORANCE WITH OBC 3.4.6.1. HANDRAIL TO CONTINUE ON SLOPE FOR A DEPTH OF ONE TREAD BEYOND BOTTOM RISER AND FOLLOWED BY A 300mm (MIN.) HORIZONTAL EXTENSION IN ACCORDANCE WITH OBC 3.4.6.5.(10) 1. 40Ø METAL HANDRAIL FASTENED TO C.I.P. CONCRETE WALL c/w PAINT 2. PROVIDE A MINIMUM CLEARANCE OF 50mm BETWEEN HANDRAIL AND ANY SURFACE IN ACCORDANCE WITH OBC 3.4.6.5.(11) 3. INSTALL HANDRAIL 920mm ABOVE TREAD NOSINGS IN ACCORDANCE WITH OBC 3.4.6.5.(4)(5) (1) HANDRAIL TO BE CONTINUOUS THROUGHOUT ITS ENTIRE LENGTH IN ACCORDANCE WITH OBC 3.4.6.5. (TYP.) SMOKE AND HEAT DETECTOR TO BE INSTALLED IN EACH EXIT STAIR SHAFT IN ACCORDANCE HOSE STATION EQUIPPED WITH FIRE WITH OBC 3.2.4.12. HOSE STATION EQUIPPED WITH FIRE WITH OBC 3.2.4.12. EXTINGUISHER TO BE LOCATED WITHIN 5m OF EXIT IN ACCORDANCE WITH OBC 3.2.9.4. EXIT SIGNAGE TO BE INSTALLED ABOVE OR ADJACENT TO EXIT DOORS IN ACCORDANCE WITH OBC 3.4.5.1 DOUBLE HEADED EMERGENCY LIGHTS IN ALL EXITS IN ACCORDANCE WITH OBC 3.2.7.3. 2H FRR FIRE SEPERATION EXITS TO BE SEPERATED FROM REMAINDER OF BUILDING BY A FIRE SEPERATION NOT LESS THAN FLOOR ASSEMBLY ABOVE IN ACCORDANCE WITH OBC 3.4.4.1. INTWA INTWA INTWA INTWA 1.B 1.5 1.4 1.C 1 A600 STAIR 'A' 210.2 EXWA EXWA 2 D.02.204.15 INTWA 1 INTWAINTWA 1 INTWA 1 EL EXIT TACTILE SURFACE SHALL BE INSTALLED AT LEADING EDGE OF THE LANDING WHERE A DOORWAY OPENS ONTO STAIRS AND AT THE TOP OF STAIRS IN ACCORANCE WITH OBC 3.4.6.1. HANDRAIL TO CONTINUE ON SLOPE FOR A DEPTH OF ONE TREAD BEYOND BOTTOM RISER AND FOLLOWED BY 300mm (MIN.) HORIZONTAL EXTENSION IN ACCORDANCE WITH OBC 3.4.6.5.(10) 1. 40Ø METAL HANDRAIL FASTENED TO C.I.P. CONCRETE WALL c/w PAINT 2. PROVIDE A MINIMUM CLEARANCE OF 50mm BETWEEN HANDRAIL AND ANY SURFACE IN ACCORDANCE WITH OBC 3.4.6.5.(11) 3. INSTALL HANDRAIL 920mm ABOVE TREAD NOSINGS IN ACCORDANCE WITH OBC 3.4.6.5.(4)(5) (1) HANDRAIL TO BE CONTINUOUS THROUGHOUT ITS ENTIRE LENGTH IN ACCORDANCE WITH OBC 3.4.6.5. (TYP.) SMOKE AND HEAT DETECTOR TO BE INSTALLED IN EACH EXIT STAIR SHAFT IN ACCORDANCE HOSE STATION EQUIPPED WITH FIRE WITH OBC 3.2.4.12. HOSE STATION EQUIPPED WITH FIRE WITH OBC 3.2.4.12. EXTINGUISHER TO BE LOCATED WITHIN 5m OF EXIT IN ACCORDANCE WITH OBC 3.2.9.4. MANUAL PULL STATION TO INSTALLED NEAR REQUIRED EXITS IN ACCORDANCE WITH OBC 3.2.4.18 EXIT SIGNAGE TO BE INSTALLED ABOVE OR ADJACENT TO EXIT DOORS IN ACCORDANCE WITH OBC 3.4.5.1 DOUBLE HEADED EMERGENCY LIGHTS IN ALL EXITS IN ACCORDANCE WITH OBC 3.2.7.3. 2H FRR FIRE SEPERATION EXITS TO BE SEPERATED FROM REMAINDER OF BUILDING BY A FIRE SEPERATION NOT LESS THAN FLOOR ASSEMBLY ABOVE IN ACCORDANCE WITH OBC 3.4.4.1. MPS HANDRAIL TO EXTEND HORIZONTALLY AT THE REQUIRED HEIGHT, NOT LESS THAN 300 BEYOND TOP RISER IN ACCORDANCE WITH 3.4.6.5. 12 TREADS @ 290 3480 2130 1370 580 300 11 TREADS @ 290 3190 625 LANDING DEPTH1505 750mm MIN.1018 590 SPRINKLER PROTECTED GLAZED WALL ASSEMBLY IN ACCORDANCE WITH OBC 3.1.18.(1) HANDRAIL HEIGHT 920 GUARDRAIL HEIGHT 1070 40Ø TOP RAIL OF GAURD c/w PAINT 40Ø STEEL HANDRAIL c/w PAINT 13Ø STEEL PICKETS SPACED TO WITHSTAND PASSAGE OF 100Ø SPHERE HATCH SLIP RESISTANT COLOUR CONTRAST NOSING (TYP.) 65 x 255 STEEL ANGLE WELDED TO STEEL STRINGER FOR INSTALLATION OF STEEL STAIR PANS -CONFIRM WITH SHOP DRAWINGS 115 NOTE: 1. ALL STEEL TO BE FINISHED WITH PAINT IN ACCORDANCE WITH SPECIFICATIONS. 2. CONTRACTOR TO CONFIRM ALL DIMENSIONS PRIOR TO STAIR FABRICATION. 3. STAIRS TO BE BUILT IN ACCORDANCE WITH APPROVED SHOP DRAWINGS. L100 0 40Ø TOP RAIL OF GAURD c/w PAINT 40Ø STEEL HANDRAIL c/w PAINT 300 TREAD DEPTH 290 13Ø STEEL PICKETS SPACED TO WITHSTAND PASSAGE OF 100Ø SPHERE 115 HANDRAIL HEIGHT 920GUARDRAIL HEIGHT 1070 HANDRAIL TO CONTINUE ON SLOPE FOR A DEPTH OF ONE TREAD BEYOND BOTTOM RISER AND FOLLOWED BY A 300mm (MIN.) HORIZONTAL EXTENSION IN ACCORDANCE WITH OBC 3.4.6.5.(10) HATCH SLIP RESISTANT COLOUR CONTRAST NOSING (TYP.) 65 x 255 STEEL ANGLE WELDED TO STEEL STRINGER FOR INSTALLATION OF STEEL STAIR PANS -CONFIRM WITH SHOP DRAWINGS 60 x 200 STEEL ANGLE WELDED TO BOTTOM OF STEEL STRINGER -CONFRIM WITH SHOP DRAWINGS 13Ø ANCHOR BOLT THROUGH STEEL ANGLE INSTALLED USING EPOXY c/w 75mm(MIN.) EMBEDMENT -CONFIRM WITH SHOP DRAWINGS 535 100mm C.I.P. CONC. SLAB ON GRADE C/W 6x6 W.W.M. & SLIP RESISTANT SURFACE IN ACCORDANCE O.B.C. 3.8.3.2 HIGH DENSITY R-15 RIGID INSULATION 150mm COMPACTED GRANULAR FILL NOTE: 1. ALL STEEL TO BE FINISHED WITH PAINT IN ACCORDANCE WITH SPECIFICATIONS. 2. CONTRACTOR TO CONFIRM ALL DIMENSIONS PRIOR TO STAIR FABRICATION. 3. STAIRS TO BE BUILT IN ACCORDANCE WITH APPROVED SHOP DRAWINGS. RISE179 RUN 290 DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A600 STAIR PLANS & SECTIONS AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 501 SEC07 -STAIR SECTION INCLUDING EXTERIOR WALL 1 502 L100 PLAN -STAIR 'A' 1 503 L200 PLAN -STAIR 'A' 1 105 STAIR DETAIL 02 -STAIR CONNECTION AT LANDING SECTION 1 104 STAIR DETAIL 01 -STAIR CONNNECTION AT L100
DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION 1.K 1.6 1.J REFUSE RM. 106 SECONDARY VEST. 107 PRECAST CONCRETE SILL 90mm BRICK VENEER 70mm AIR-SPACE W/ 22 Ga. CORRUGATED MASONRY WALL TIES EXTERIOR GRADE SHEATHING 140mm ENGINEERED METAL STUDS @ 400mm C/C TYP. C.I.P. POURED CONCRETE WALL 65mm METAL STUD @ 400 O.C. 16mm TYPE 'X' GYPSUM WALLBOARD SCREW FASTENER c/w DRYWALL COMPOUND AND SANDED FILL STUD CAVITY WITH SOUND ABSORPTIVE MATERIAL (TYP.) C.I.P. POURED CONCRETE WALL 65mm METAL STUD @ 400 O.C. 16mm TYPE 'X' GYPSUM WALLBOARD SCREW FASTENER c/w DRYWALL COMPOUND AND SANDED FILL STUD CAVITY WITH SOUND ABSORPTIVE MATERIAL (TYP.) 13mm GYPSUM WALLBOARD 140mm ENGINEERED METAL STUDS @ 400mm C/C TYP. EXTERIOR GRADE SHEATHING R24 CLOSED CELL POLY-UTHERANE SPRAY FOAM 50mm AIR-SPACE W/ 22 Ga. CORRUGATED MASONRY WALL TIES 90mm BRICK VENEER PRECAST CONCRETE SILL TRANSITION MEMBRANE TUCK INTO CURTAIN WALL SYSTEM CONFRIM WITH CURTAIN WALL SYSTEM SHOP DRAWINGS PRE FINISHED METAL FLASHING FLASHING TO BE FASTENED TO BRICK VENEER AND INTO PRESSURE CAP OF CURTAIN WALL MULLION CONFIRM WITH SHOP CURTAIN WALL SHOP DRAWINGS L100 0 1.6 125 75 150 125 75 150 470 75 545 86 114 345 FL SFDN 2 SPRINKLER PROTECTED GLAZED WALL ASSEMBLY IN ACCORDANCE WITH 3.1.18. (1) 100mm C.I.P. CONCRETE SLAB ON GRADE HIGH DENSITY R-15 RIGID INSULATION 150mm COMPACTED GRANULAR FILL 470mm C.I.P REINFORCED CONCRETE FOUNDATION WALL. REFER TO STRUCTURAL DRAWINGS. HIGH DENSITY R-15 RIGID INSULATION. 405 LONG 15M DOWEL TO TIE CONCRETE FLOOR TO CONCRETE FOUNDATION WALL REFER TO STRUCTURAL DRAWINGS PRE FINISHED METAL BARRIER FREE THRESHOLD IN ACCORDANCE WITH OBC 3.8.1.3 150mm COMPACTED GRANULAR FILL HIGH DENSITY R 15 RIGID INSULATION 100mm C.I.P. CONCRETE SLAB ON GRADE THRESHOLD TO BE BEVELLED AT A MAXIMUM SLOPE OF 1 IN SECONDARY VEST. 107 2.1 2.S LIVING AREA 208.4 DINING AREA 208.5.1 KITCHEN 209.3 3" ALUMAX ACM PANEL (IVORY) 50mm AIR-SPACE W/ Z-GIRTS @ 600mm O.C. HORIZONTALLY R24 CLOSED CELL POLY-UTHERANE SPRAY FOAM EXTERIOR GRADE SHEATHING 140mm METAL STUD @ 400 O.C. 13mm GYPSUM WALLBOARD SCREW FASTENER c/w DRYWALL COMPOUND AND SANDED SPRAY FOAM BETWEEN ROUGH OPENING AND FINISH TRIM (TYP.) WOOD JAMB AND CASING c/w PAINT REFER TO ROOM FINISH SCHEDULE FOR DETAILS 140mm METAL STUD @ 400 O.C. 13mm GYPSUM WALLBOARD PRE FINISHED ACM FLASHING TO MATCH ACM PANELING FLASHING TO BE FASTENED TO BACK OF ACM PANELLING AND INTO WINDOW JAMB 250x1200mm 13mm GYPSUM WALL BOARD INTERIOR WALL (INT 4) TO ACT AS FIRE SEPARATION FIRE SEPARATION TO HAVE 1HR FIRE RESISTANCE RATING IN ACCORDANCE WITH OBC 3.3.4.2. BENT ANGLE FASTENED TO EXTERIOR SHEATHING TO RPOVIDE STOP FOR SPRAY FOAM INSULATION SPRAY FOAM BETWEEN ROUGH OPENING AND FINISH TRIM (TYP.) WOOD JAMB AND CASING c/w PAINT REFER TO ROOM FINISH SCHEDULE FOR DETAILS PRE FINISHED ACM FLASHING TO MATCH ACM PANELING FLASHING TO BE FASTENED TO BACK OF ACM PANELLING AND INTO WINDOW JAMB BENT ANGLE FASTENED TO EXTERIOR SHEATHING TO RPOVIDE STOP FOR SPRAY FOAM INSULATION 3" ALUMAX ACM PANEL (IVORY) 50mm AIR-SPACE W/ Z-GIRTS @ 600mm O.C. HORIZONTALLY R24 CLOSED CELL POLY-UTHERANE SPRAY FOAM EXTERIOR GRADE SHEATHING 65mm METAL STUD @ 400 O.C. REFER TO STRUC. DWG'S SCREW FASTENER c/w DRYWALL COMPOUND AND SANDED 13mm GYPSUM WALL BOARD 65mm METAL STUD @ 400 O.C. REFER TO STRUC. DWG'S SCREW FASTENER c/w DRYWALL COMPOUND AND SANDED 13mm GYPSUM WALL BOARD 65mm METAL STUD @ 400 O.C. REFER TO STRUC. DWG'S 13mm GYPSUM WALL BOARD 200mm C.I.P. POURED CONCRETE WALL DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A700 CONSTRUCTION DETAILS AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 10A200 DETAIL02 -EXTERIOR CORNER PLAN2 1 5A500 DETAIL01 -FOUNDATION WALL AT BARRIER FREE ENTRANCE SECTION @ GRADE1 1 10A220.2 DETAIL03 -INTERIOR CORNER PLAN3
DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION ROOF 28200 6.9 WOOD SHAKES INTERLOCKING ROOF TILES BATTENS AND COUNTER BATTENS EXTERIOR GRADE SHEATHING R-30 WOOD FIBRE INSULATION BOARD EXTERIOR GRADE SHEATHING 125mm DEEP Z-GIRTS 3" ALUMAX ACM PANEL (IVORY) Z-GIRTS @ 600mm O.C. HORIZONTALLY R24 CLOSED CELL POLY-UTHERANE SPRAY FOAM EXTERIOR GRADE SHEATHING 13mm GYPSUM WALLBOARD REFER TO ROOM FINISH SCHEDULE FOR FINISHES 140x915 M LVL BEAM ACM METAL PARAPET FLASHING WOOD BLOCKS TO ACCOMODATE ACM FLASHING SLOPE TAPERED RIGID INSULATION Z-GIRTS @ 200mm O/C HORIZONTALLY 25mm AIR SPACE R24 CLOSED CELL POLYURETHANE SPRAY FOAM EXTERIOR GRADE SHEATHING BOARD FILL WITH STUD INSULATION 13mm CHANNEL SECTION @ 200mm O/C VERTICALLY 13mm CEMENTIOUS BOARD M N 2% S OPE 207 697 471 1375 7651127 13 14012 L600 21000 6.10 250 367 275 3" ALUMAX ACM PANEL (IVORY) 13mm CEMENTIOUS BOARD 13mm METAL CHANNELS @ 400mm O/C HORIZONTALLY EXTERIOR GRADE SHEATHING 140mm ENGINEERED METAL STUDS @ 400mm C/C TYP. EXTERIOR GRADE SHEATHING R24 CLOSED CELL POLY-UTHERANE SPRAY FOAM R30 RIGID INSULATION TAPERED RIGID INSULATION EXTERIOR GRADE SHEATHING WOOD BLOCKING TO SUIT 5% SLOPE 50mm AIR-SPACE W/ Z-GIRTS @ 600mm O.C. HORIZONTALLY 3" ALUMAX ACM PANEL (IVORY) SINGLE PLY EPDM ROOFING MEMBRANE COARSE AGGREGATE DRAINAGE BORDER SINGLE LAYER FILTER FABRIC 13Ø ANCHOR BOLT @ 1200 o/c MIN. 2% SLOPE SHOCK ISOKORB THERMAL BREAK -REFER TO STRUCTURAL DRAWINGS J-TRIM FASTENED TO Z-GIRT FLOORS TO BE FIRE SEPARATIONS WITH 2H FRR (min.) IN ACCORDANCE WITH OBC 3.1.3.1. (TYP.) 3" ALUMAX ACM PANEL (PEARL BLACK) EXTERIOR GRADE SHEATHING WOOD BLOCKING TO SUIT 5% SLOPE ANGLE SCREWED TO GIRT AND METAL STUD 25mm DEEP Z-GIRTS @ 400mm O/C HORIZONTALLY EXTERIOR GRADE SHEATHING 200mm ENGINEERED METAL STUDS @ 400mm C/C TYP. 13Ø ANCHOR BOLT @ 1200 o/c J-TRIM FASTENED TO Z-GIRT EXTERIOR GRADE SHEATHING 125mm DEEP Z-GIRTS 3" ALUMAX ACM PANEL (PEARL BLACK) 41 209 342 300 514 1406 300 13 125 76 76 25 1314013 25 76 76511271314013 13 13 7651127 13 14013 L200 5000 2.7 13mm GYPSUM WALLBOARD 65mm METAL STUD @ 400 O.C. EXTERIOR GRADE SHEATHING R24 CLOSED CELL POLY-UTHERANE SPRAY FOAM 50mm AIR-SPACE W/ Z-GIRTS @ 600mm O.C. HORIZONTALLY 3" ALUMAX ACM PANEL (IVORY)50mm SEDDUM LAYER 75mm SOIL LAYER 25mm HIGH DENSITY POLYETHYLENE DRAINAGE BOARD R30 RIGID INSULATION SINGLE LAYER FILTER FABRIC SINGLE PLY EPDM ROOFING MEMBRANE 600mm C.I.P. CONCRETE TRANSFER SLAB 900mm C.I.P. CONCRETE TRANSFER SLAB TRIM FASTENED TO GIRT COARSE AGGREGATE DRAINAGE BORDER SINGLE LAYER FILTER FABRIC PROVIDE STEEL ANGLE R30 RIGID INSULATION FLOORS TO BE FIRE SEPARATIONS WITH 2H FRR (min.) IN ACCORDANCE WITH OBC 3.1.3.1. (TYP.) 60012525755025875 L600 21000 6.4 300 300 13 140 13 127 51 76 16 65 200 65 16 300 125 150 25 50 100 125 300 600 50mm SEDDUM LAYER 75mm SOIL LAYER 25mm HIGH DENSITY POLYETHYLENE DRAINAGE BOARD R30 RIGID INSULATION SINGLE LAYER FILTER FABRIC SINGLE PLY EPDM ROOFING MEMBRANE TRIM FASTENED TO Z GIRT COARSE AGGREGATE DRAINAGE BORDER SINGLE LAYER FILTER FABRIC PROVIDE STEEL ANGLE R30 RIGID INSULATION 3" ALUMAX ACM PANEL (IVORY) 50mm AIR-SPACE W/ Z-GIRTS @ 600mm O.C. HORIZONTALLY R24 CLOSED CELL POLY-UTHERANE SPRAY FOAM EXTERIOR GRADE SHEATHING 140mm METAL STUD @ 400 O.C. 13mm GYPSUM WALLBOARD 16mm TYPE 'X' GYPSUM WALLBOARD REFER TO ROOM FINISH SCHEDULE FOR FINISHES 65mm METAL STUD @ 400 O.C. REFER TO STRUC. DWG'S C.I.P. POURED CONCRETE WALL RF RF 3 FL 5 FL 300mm C.I.P. CONCRETE TRANSFER SLAB FLOORS TO BE FIRE SEPARATIONS WITH 2H FRR (min.) IN ACCORDANCE WITH OBC 3.1.3.1. (TYP.) DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A701 CONSTRUCTION DETAILS AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 10A500 DETAIL 05 -ROOF SECTION @ L7002 1 10A500 DETAIL 04 -PARARPET, ROOF, WALL SECTION @ L6001 1 10A500 DETAIL 07 DROP SLAB AT L200 SECTION DETAIL4 1 10A500 DETAIL 06 DROP SLAB, WALL AND ROOF INTERSECTION AT L600 SECTION DETAIL3
DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION 3" ALUMAX ACM PANEL (IVORY) 50mm AIR-SPACE W/ Z-GIRTS @ 600mm O.C. HORIZONTALLY R24 CLOSED CELL POLY-UTHERANE SPRAY FOAM EXTERIOR GRADE SHEATHING 140mm METAL STUD @ 400 O.C. SCREW FASTENER c/w DRYWALL COMPOUND AND SANDED SPRAY FOAM BETWEEN ROUGH OPENING AND FINISH TRIM (TYP.) WOOD JAMB AND CASING c/w PAINT REFER TO ROOM FINISH SCHEDULE FOR DETAILS 13mm GYPSUM WALLBOARD PRE FINISHED ACM FLASHING TO MATCH ACM PANELING FLASHING TO BE FASTENED TO BACK OF ACM PANELLING AND INTO WINDOW JAMB BENT ANGLE FASTENED TO EXTERIOR SHEATHING TO RPOVIDE STOP FOR SPRAY FOAM INSULATION NOTE: 1. CONFRIM WINDOW INSTALLATION METHOD WITH WINDOW MANUFACTURER AND SHOP DRAWINGS. 2. CONTRACTOR TO CONFIRM ALL ROUGH OPENINGS PRIOR TO FABRICATION OF WINDOW. SCREW FASTENER c/w DRYWALL COMPOUND AND SANDED SPRAY FOAM BETWEEN ROUGH OPENING AND FINISH TRIM (TYP.) WOOD JAMB AND CASING c/w PAINT REFER TO ROOM FINISH SCHEDULE FOR DETAILS TRANSITION MEMBRANE TUCK INTO WINDOW MULLION CONFIRM WITH WINDOW MANUFACTURER SHOP DRAWINGS BENT ANGLE FASTENED TO EXTERIOR SHEATHING, TO PROVIDE STOP FOR SPRAY FOAM INSULATION NOTE: 1. CONFRIM WINDOW INSTALLATION METHOD WITH WINDOW MANUFACTURER AND SHOP DRAWINGS. 2. CONTRACTOR TO CONFIRM ALL ROUGH OPENINGS PRIOR TO FABRICATION OF WINDOW. 13mm GYPSUM WALLBOARD 140mm METAL STUD @ 400 O.C. EXTERIOR GRADE SHEATHING R24 CLOSED CELL POLY-UTHERANE SPRAY FOAM 50mm AIR-SPACE W/ Z-GIRTS @ 600mm O.C. HORIZONTALLY 3" ALUMAX ACM PANEL (IVORY) PRE FINISHED ACM FLASHING TO MATCH ACM PANELING FLASHING TO BE FASTENED TO BACK OF ACM PANELLING AND INTO WINDOW JAMB 246 83 102 13 140 13 127 51 76 SCREW FASTENER c/w DRYWALL COMPOUND AND SANDED SPRAY FOAM BETWEEN ROUGH OPENING AND FINISH TRIM (TYP.) WOOD JAMB AND CASING c/w PAINT REFER TO ROOM FINISH SCHEDULE FOR DETAILS TRANSITION MEMBRANE TUCK INTO WINDOW MULLION CONFIRM WITH WINDOW MANUFACTURER SHOP DRAWINGS BENT ANGLE FASTENED TO EXTERIOR SHEATHING, TO PROVIDE STOP FOR SPRAY FOAM INSULATION 13mm GYPSUM WALLBOARD 140mm METAL STUD @ 400 O.C. EXTERIOR GRADE SHEATHING R24 CLOSED CELL POLY-UTHERANE SPRAY FOAM 50mm AIR-SPACE W/ Z-GIRTS @ 600mm O.C. HORIZONTALLY 3" ALUMAX ACM PANEL (PEARL BLACK) PRE FINISHED ACM FLASHING TO MATCH ACM PANELING FLASHING TO BE FASTENED TO BACK OF ACM PANELLING AND INTO WINDOW JAMB NOTE: 1. CONFRIM WINDOW INSTALLATION METHOD WITH WINDOW MANUFACTURER AND SHOP DRAWINGS. 2. CONTRACTOR TO CONFIRM ALL ROUGH OPENINGS PRIOR TO FABRICATION OF WINDOW. 246 83 102 13 140 13 127 51 76 L200 5000 1.51.6 252 600 x 600mm COLUMN BEYOND FL 4 FL 2 600mm C.I.P. CONCRETE TRANSFER SLAB 900mm C.I.P. CONCRETE TRANSFER SLAB C.I.P. POURED CONCRETE WALL FL 4 C.I.P. POURED CONCRETE WALL 200 155 SPRINKLER PROTECTED GLAZED WALL ASSEMBLY -IN ACCORDANCE WITH 3.1.18. (1) SPRAY FOAM BETWEEN ALMUMINIUM MULLIONS EXTRUDED ALUMINIUM MEMBER SCREWED TO EACHOTHER BACK PAN SEALED TO CURTAIN WALL GLAZING POCKET ROOFING MEMBRANE CLAMPED AND SEALED INTO GLAZING POCKET TAPERED RIGID INSULATION FILL WITH BATT INSULATION 50mm AIR SPACE ALUMINIUM PANEL FORMED COPING R24 CLOSED CELL POLYURETHANE SPRAY FOAM 13mm CEMENTIOUS BOARD SINGLE PLY EPDM ROOFING MEMBRANE ALUMINIUM PANEL FORMED METAL FLASHING 300 600 WRAP SINGLE PLAY EPDM MEMBRANE 600mm VERTICALLY UP WALL 13Ø ANCHOR BOLT @ 1200 o/c 13mm GYPSUM WALLBOARD REFER TO ROOM FINISH SCHEDULE FOR FINISHES 140mm ENG. METAL STUD @ 400 O/C TYP. FLOORS TO BE FIRE SEPARATIONS WITH 2H FRR (min.) IN ACCORDANCE WITH OBC 3.1.3.1. (TYP.) EXTERIOR GRADE SHEATHING R24 CLOSED CELL POLY-UTHERANE SPRAY FOAM Z-GIRTS @ 600mm O.C. HORIZONTALLY 3" ALUMAX ACM PANEL (IVORY) SPRAY FOAM BETWEEN ROUGH OPENING AND FINISH TRIM (TYP.) TRANSITION MEMBRANE TUCK INTO WINDOW MULLION CONFIRM WITH WINDOW MANUFACTURER SHOP DRAWINGS TRANSITION MEMBRANE TUCK INTO CURTAIN WALL MULLION CONFIRM WITH CURTAIN WALL MANUFACTURER SHOP DRAWINGS RF 3 R30 RIGID INSULATION SINGLE PLY EPDM ROOFING MEMBRANE SINGLE LAYER FILTER FABRIC COARSE AGGREGATE DRAINAGE BORDER J-TRIM FASTENED TO Z-GIRT GLAZED ROOFING WITH INSULATED TEMPERED GLASS WOOD BLOCK TO SUIT TAPERED RIGID INSULATION EXTERIOR GRADE PLYWOOD SHEATHING ANGLE SCREWED TO SUPPORT MULLION ALUMINIUM FLASHING HSS BEAM SCREWED TO CONCRETE WALL AND WOOD BLOCKING TO SUPPORT GLAZED ROOFING WOOD BLOCK SCREWED TO MULLION TO SUIT. SEE GLAZED ROOFING MANUFACTURER'S SHOP DRAWING FOR DETAILS 13mm GYPSUM WALL BOARD L500 17000 M N 1 0 7 0 m m G U A R D R A L H E G H T 1210 514 WRAP SINGLE PLAY EPDM MEMBRANE 13Ø ANCHOR BOLT @ 1200 o/c FLOORS TO BE FIRE SEPARATIONS WITH 2H FRR (min.) IN ACCORDANCE WITH OBC 3.1.3.1. (TYP.) SPRAY FOAM BETWEEN ROUGH OPENING AND FINISH TRIM (TYP.) TRANSITION MEMBRANE TUCK INTO WINDOW MULLION CONFIRM WITH WINDOW MANUFACTURER SHOP DRAWINGS SHOCK ISOKORB THERMAL BREAK REFER TO STRUCTURAL DRWINGS 13Ø ANCHOR BOLT @ 1200 o/c TRIM FASTENED TO Z GIRT 13mm GYPSUM WALLBOARD 140mm METAL STUD @ 400 O.C. EXTERIOR GRADE SHEATHING R24 CLOSED CELL POLY-UTHERANE SPRAY FOAM 50mm AIR-SPACE W/ Z-GIRTS @ 600mm O.C. HORIZONTALLY 3" ALUMAX ACM PANEL (IVORY) GLASS IN GUARD SHALL NOT BE IN DIRECT CONTACT WITH ANY METAL OR SIMILAR HARD ELEMENTS GLASS IN GUARD SHALL BE EQUIPPED WITH SUFFICIENT ALLOWANCES THAT INCORPORATE DEFLECTION AND MOVEMENT UNDER LOADS AND EXPANSION AND CONTRACTION DUE TO TEMPERATURE IN ACCORDANCE WITH OBC SB 13 GUARD BALLUSTERS TO BE EQUIPPED WITH ANGLES WELDED TO BOTTOM PROVIDE 13Ø INTO PLYWOOD AND WOOD BLOCKS CAULK AND SEAL WHERE GLASS ATTAHED TO ACM CLADDING PREFINISHED ANNODIZED ALUMINUM GUARD RAIL PROVIDE 13Ø INTO WOOD BLOCK AND CONCRETE SLAB Z GIRTS HOLDING ACM CLADDING, SCREWED WITH 13Ø INTO EXTERIOR GARDE SHEATING INTO CONCRETE SLAB DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A702 CONSTRUCTION DETAILS AD 04/20/21 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 5 DETAIL 08.3 TYP. EXTERIOR WINDOW JAMB DETAIL 1 5 DETAIL 08.1 TYP. EXT. WINDOW SILL SECTION DETAIL 1 5 DETAIL 08.2 TYP. EXT. WINDOW HEAD SECTION DETAIL 10A500 DETAIL09 -ENTRANCE CANOPY SKYLIGHT SECTION4 1 10A500 DETAIL10 -GUARDRAIL SECTION @ BALCONY5
REF. A8003 4 B.C.-4 300 B.C.-1 800 FULL HEIGHT B.C.-6 600 FULL HEIGHT B.C.-5 600 13 368 356 U.C.-1 600 U.C.-2 500 U.C.-2 500 U.C.-2 500 U.C.-2 500 BASE CABINETS 2300 682 42 UPPER CABINETS 2600 908 GASSTOVE&RANGEHOOD 760 U.C.-3 1123 U.C.-2 500 U.C.-2 500 U.C.-2 500 U.C.-1 600 356 368 UPPER CABINETS 3223 42 682 B.C.-2 600 B.C.-2 600 B.C.-1 800 B.C.-1 800 BASE CABINETS 2800 B.C.-3 600 B.C.-3 600 B.C.-3 600 B.C.-4 300 60 60 234 420 654 1200 1486 INTERLOCKING GLASS MESH -MOUNTED MOSAIC TILE BACKSPLASH STAINLESS STEEL REFRIGERATOR -REFER TO SPECIFICATIONS. C O U N T E R W I D T H 636 85 1100 2145 38mmTHICK GRANITE COUNTER TOP -REFER TO MILLWORK SCHEDULE (TYP.) STAINLESS STEEL GAS STOVE -REFER TO SPECIFICATIONS FOR DETAILS. LINE INDICATES EXTENTS OF BASE CABINET FRAME 18mmCOUNTERTOP OVERHANG FROM EDGE OF CABINET FRAME (TYP.) -UNO GFCI GFCIGFCI GFCI GFCI STAINLESS STEEL SINK REFER TO SPECIFICATIONS FOR DETAILS. 2 L300 500 9000 GFCI GFCI TO CENTRETYP. 245 TO CENTRETYP. 245 INTERLOCKING GLASS MESH MOUNTED MOSAIC TILE BACKSPLASH STAINLESS STEEL REFRIGERATOR REFER TO SPECIFICATIONS. STAINLESS STEEL GAS STOVE REFER TO SPECICFICATIONS FOR DETAILS. STAINLESS STEEL SINK REFER TO SPECIFICATIONS FOR DETAILS. STAINLESS STEEL RANGE HOOD REFER TO SPECIFICATION FOR DETAILS GFCI RECEPTACLE WHITE COVER (TYP.) 343 2100 510 290 705 38 800 100 1257 2443 350 18 356 U.C.-1 600 U.C.-2 500 U.C.-2 500 U.C.-2 500 U.C.-3 1123 721427B.C.-1800B.C.-1800B.C.-2600B.C.-2600 DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION L300 500 9000 GFCIGFCI TO CENTRETYP. 2452100 104 100 1543 800 10080038705290510TO CENTRETYP. 245 908U.C.-2500U.C.-2500U.C.-2500U.C.-2500U.C.-160035618350 INTERLOCKING GLASS MESH MOUNTED MOSAIC TILE BACKSPLASH STAINLESS STEEL REFRIGERATOR REFER TO SPECIFICATIONS. STAINLESS STEEL GAS STOVE REFER TO SPECICFICATIONS FOR DETAILS. STAINLESS STEEL SINK REFER TO SPECIFICATIONS FOR DETAILS. STAINLESS STEEL RANGE HOOD REFER TO SPECIFICATION FOR DETAILS GFCI RECEPTACLE WHITE COVER (TYP.) 24431257 908 FULL HEIGHT B.C.-5600 FULL HEIGHT B.C.-6600B.C.-1800B.C.-4300388 COUNTER WIDTH 636 L300 500 9000 38 800 100 1008003870580090 HIGH TOE KICK (TYP.) CABINET REFER TO MILLWORK SCHEDULE 18mm COUNTERTOP OVERHANG FROM EDGE OF CABINET FRAME (TYP.) UNO 38mmTHICK GRANITE COUNTER TOP REFER TO MILLWORK SCHEDULE (TYP.) B.C.-3600B.C.-3600B.C.-3600B.C.-4300 1220618 35318350 CABINET REFER TO MILLWORK SCHEDULE STAINLESS STEEL REFRIGERATOR REFER TO SPECIFICATIONS. 500 800 247353 800 15 240 15 225 15 275 15 800 100 900 800 100 900 800 100 900 15 240 15 225 15 275 15 100 900 1123 15 240 15 225 15 510 1525 100 1625 355 20 530 620 100 1625 U.C.-3 ABOVE THE SINK OPEN UPPER CABINET U.C.-2 UPPER CABINET-LHS DOOR U.C.-1 OPEN UPPER CABINET 800 600 600 180420 600 600 B.C.-1 BASE CABINET -DRAWERS B.C.-3 BASE CABINET -DRAWERS B.C.-2 BASE CABINET -LHS DOOR B.C.-4 OPEN BASE CABINET T.C.-1 TALL CABINET -LHS DOOR T.C.-2 TALL MICROWAVE CABINET 600 600 MILLWORK NOTES: 1. ALL CABINETS TO BE SCRIBED TO FIT WALL. FINISH JOINT BETWEEN WALL AND CABINET WITH PAINTABLE LATEX SILICONE. 2. ALL CABINET BOXES TO BE FASTENED TOGETHER USING TYPICAL FASTNERS. 3. PROVIDE WOOD FACE FRAME c/w PAINT THAT COVERS ALL CABINER BOX JOINTS. 4. MILLWORK COUNTERTOP TO BE MEAUSRED ON SITE AFTER BASE CABINETS HAVE BEEN INSTALLED. 5. ALL APPLIANCES TO BE AS PER SPECIFICATIONS. CONTRACTOR TO CONFIRM ALL CLEARENCES WITH MANUFACTURER. PENTHOUSE KITCHEN MILLWORK SCHEDULE: TYPE MARK U.C.-1 DESCRIPTION ABOVE THE SINK OPEN UPPER CABINET UPPER CABINET -LHS DOOR OPEN UPPER CABINET BASE CABINET -DRAWERS TALL CABINET -LHS DOOR QUANTITY 2 1 3 2 3 2 1 1 WIDTH 600 DEPTH 368 HEIGHT 800 FINISH PAINT U.C.-2 U.C.-3 B.C.-1 B.C.-2 B.C.-3 B.C.-4 T.C.-1 T.C.-2 BASE CABINET -LHS DOOR OPEN BASE CABINET TALL MICROWAVE CABINET 7 BASE CABINET -DRAWERS 500 368 800 1123 368 510 800 618 900 600 900 600 900 600 900 600 600 1625 618 618 618 618 618 1625 PAINT PAINT PAINT PAINT PAINT PAINT PAINT PAINT DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A800 KITCHEN PLAN & INTERIOR ELEVATIONS W/ MILLWORK SCHEDULE AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 20A221 L300-500 ENLARGED TYP. KITCHEN FLOOR PLAN1 1 20A221 KITCHEN ELEVATION 'B'3 1 20A221 KITCHEN ELEVATION 'A'2 1 20A221 KITCHEN ELEVATION 'D'4
DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION A8013 2 5 4 B T RN NG D AME ER ø 7 0 DOOR OPERATOR IN ACCORDANCE WITH OBC 3.8.1.5.CLEAR SPACE MIN. 300 CLEAR SPACE MIN.600 920mm WIDE 1370mm DEEP LAVATORY APPROACH SPACE 900mm WIDE x 1500mm DEEP CLEAR TRANSFER SPACE 760mm WIDE 1100mm DEEP CLEAR SPACE 810mm 1830mm CLEAR SPACE ADULTSIZE CHANGE TABLE PROVIDE SOLID WOOD BLOCKING IN WALLS WHERE FUTURE ADULT SIZE CHANGE TABLE IS PROPOSED. WOOD BLOCKING TO BE DESIGNED TO CARRY MINIMUM LOADS OF 1.33 kN IN ACCORDANCE WITH OBC 3.8.3.12.(3)(4)(5) TOILET PAPER DISPENSER LOCATED NOT LESS THAN 600 ABOVE FINISHED FLOOR AND NOT MORE THAN 300 FROM FRONT OF WATER CLOSET IN ACCORDANCE WITH OBC 3.8.3.8(1) EMERGENCY CALL BUTTON IN ACCORDANCE IS OBC 3.8.3.12. SLIP RESISTANT 38mmØ STAINLESS STEEL HORIZONTAL GRAB BAR IN ACCORDANCE WITH OBC 3.8.3.8.(6)(7) GRAB BAR TO HAVE NOT LESS 38mm AND NOT MORE THAN 50mm FROM WALL TO INSIDE SURFACE OF GRAB BAR IN ACCORDANCE WITH OBC 3.8.3.8.(7) WATER CLOSET EQUIPPED WITH BACK SUPPORT IN ACCORDANCE WITH OBC 3.8.3.9 SHELF LOCATED NOT MORE 1100mm AFF w/ COAT HOOK IN ACCORDANCE WITH OBC 3.8.3.12.(1) STAINLESS STEEL SHELF LOCATED 200mm ABOVE LAVATORY BUT NOT MORE THAN 1100mm AFF IN ACCORDANCE WITH OBC 3.8.3.11.(4) MIRROR MOUNTED TO WALL 1000mm AFF MIRROR TO BE EQUIPPED WITH TILT CAPABILITIES IN ACCORDANCE WITH OBC 3.8.3.12.(1)(j) LAVATORY IN ACCORDANCE WITH OBC 3.8.3.11 SOAP DISPENSER IN ACCORDANCE WITH OBC 3.8.3.11.(1)(g) D.02.204.13 610mm MAX. 500 460 6 1 0 m m M A X 150 L200 5000 200mm METAL CEILING JOISTS @ 600 o/c 13mm GYPSUM WALLBOARD REFER TO ROOM FINISH SCHEDULE CERAMIC TILE REFER TO ROOM FINISH SCHEDULE. BACK SPLASH TILE TO BE INSTALLED SO THAT EQUAL SIZE TILES ARE PLACED ADJACENT TO WALLS. PAPER TOWEL DISPENSER TRASH CAN MIRROR 1200mm MAX.1000 MIRROR MOUNTED TO WALL 1000mm AFF MIRROR TO BE EQUIPPED WITH TILT CAPABILITIES IN ACCORDANCE WITH OBC 3.8.3.12.(1)(j) STAINLESS STEEL SHELF LOCATED 200mm ABOVE LAVATORY BUT NOT MORE THAN 1100mm AFF IN ACCORDANCE WITH OBC 3.8.3.11.(4) LAVATORY IN ACCORDANCE WITH OBC 3.8.3.11. PIPES TO BE INSULATED TO PROVIDE A MAXIMUM TEMPERATURE OF 43°C IN ACCORDANCE WITH OBC 3.8.3.11.(1) 610mm MAX. 500 MIN.430485mm MAX. 440 HORIZONTAL GRAB BAR 600150 SLIP RESISTANT 38Ø STAINLESS STEEL HORIZONTAL GRAB BAR IN ACCORDANCE WITH OBC 3.8.3.8.(6)(7) GRAB BAR TO HAVE NOT LESS 38mm AND NOT MORE THAN 50mm FROM WALL TO INSIDE SURFACE OF GRAB BAR IN ACCORDANCE WITH OBC 3.8.3.8.(7) T/O LAVATORY840 BOTTTOM OF MIRROR 1000SHELF HEIGHT987 WATER CLOSET EQUIPPED WITH BACK SUPPORT IN ACCORDANCE WITH OBC 3.8.3.9 L-GRAB BAR 750 150 L200 5000 200mm METAL CEILING JOISTS @ 600 o/c 13mm GYPSUM WALLBOARD REFER TO ROOM FINISH SCHEDULE CERAMIC TILE REFER TO ROOM FINISH SCHEDULE. BACK SPLASH TILE TO BE INSTALLED SO THAT EQUAL SIZE TILES ARE PLACED ADJACENT TO WALLS. T/O LAVATORY840 FRONT EDGE 777 TOE CLEARANCE350 KNEE CLEARANCE 685 B/O MIRROR1000 MIRROR MOUNTED TO WALL 1000mm AFF MIRROR TO BE EQUIPPED WITH TILT CAPABILITIES IN ACCORDANCE WITH OBC 3.8.3.12.(1)(j) STAINLESS STEEL SHELF LOCATED 200mm ABOVE LAVATORY BUT NOT MORE THAN 1100mm AFF IN ACCORDANCE WITH OBC 3.8.3.11.(4) LAVATORY IN ACCORDANCE WITH OBC 3.8.3.11. PIPES TO BE INSULATED TO PROVIDE A MAXIMUM TEMPERATURE OF 43°C IN ACCORDANCE WITH OBC 3.8.3.11.(1) 610mm MAX. 150 SOAP DISPENSER IN ACCORDANCE WITH OBC 3.8.3.11.(1)(g) 1200mm MAX. SOAP DISPENSER HEIGHT 1000 EMERGENCY CALL SYSTEM THAT CONSISTS OF AUDIBLE AND VISUAL SIGNAL DEVICES INSIDE AND OUTSIDE OF THE WASHROOM THAT ARE ACTIVATED BY A CONTROL DEVICE INSIDE THE WASHROOM IN ACCORDANCE WITH OBC 3.8.1.5. L200 5000 1100mm MAX. 900 D.02.204.13 200mm METAL CEILING JOISTS @ 600 o/c 13mm GYPSUM WALLBOARD REFER TO ROOM FINISH SCHEDULE CERAMIC TILE REFER TO ROOM FINISH SCHEDULE. BACK SPLASH TILE TO BE INSTALLED SO THAT EQUAL SIZE TILES ARE PLACED ADJACENT TO WALLS. EMERGENCY CALL SYSTEM THAT CONSISTS OF AUDIBLE AND VISUAL SIGNAL DEVICES INSIDE AND OUTSIDE OF THE WASHROOM THAT ARE ACTIVATED BY A CONTROL DEVICE INSIDE THE WASHROOM IN ACCORDANCE WITH OBC 3.8.1.5. HATCHED REGION INDICATES 810mm X 1830mm FUTURE ADULT SIZE CHANGE TABLE. PROVIDE SOLID WOOD BLOCKING IN WALLS WHERE FUTURE ADULT SIZE CHANGE TABLE IS PROPOSED. WOOOD BLOCKING TO BE DESIGNED TO CARRY MINIMUM LOADS OF 1.33 KN IN ACCORDANCE WITH OBC 3.8.3.12.(3)(4)(5) NOTE: AN EMERGENCY SIGN THAT CONTAINS THE WORDS IN THE EVENT OF AN EMERGENCY PUSH EMERGENCY BUTTON AND AUDIBLE AND VISUAL SIGNAL WILL ACTIVATE IN LETTERS AT LEAST 25mm HIGH WITH A 5mm STROKE AND THAT IS POSTED ABOVE EMERGENCY BUTTON. L200 5000 SLIP RESISTANT 38Ø STAINLESS STEEL HORIZONTAL GRAB BAR IN ACCORDANCE WITH OBC 3.8.3.8.(6)(7) GRAB BAR TO HAVE NOT LESS 38mm AND NOT MORE THAN 50mm FROM WALL TO INSIDE SURFACE OF GRAB BAR IN ACCORDANCE WITH OBC 3.8.3.8.(7) WATER CLOSET EQUIPPED WITH BACK SUPPORT IN ACCORDANCE WITH OBC 3.8.3.9 TOILET PAPER DISPENSER LOCATED NOT LESS THAN 600mm AFF AND NOT MORE THAN 300mm FROM FRONT OF WATER CLOSET IN ACCORDANCE WITH OBC 3.8.3.8(1) 280 L-GRAB BAR 750 750 150 300 M N 4 3 0 m m 4 8 5 m m M A X 440 T O L E T P A P E R D I S P E N S E R H E G H T 600mm MIN. 620 200mm METAL CEILING JOISTS @ 600 o/c 13mm GYPSUM WALLBOARD REFER TO ROOM FINISH SCHEDULE CERAMIC TILE REFER TO ROOM FINISH SCHEDULE. BACK SPLASH TILE TO BE INSTALLED SO THAT EQUAL SIZE TILES ARE PLACED ADJACENT TO WALLS. EMERGENCY CALL SYSTEM THAT CONSISTS OF AUDIBLE AND VISUAL SIGNAL DEVICES INSIDE AND OUTSIDE OF THE WASHROOM THAT ARE ACTIVATED BY A CONTROL DEVICE INSIDE THE WASHROOM IN ACCORDANCE WITH OBC 3.8.1.5. DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A801 B.F. WASHROOM PLAN & INTERIOR ELEVATIONS AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT DEVELOPMENTS 1 201 L200 B.F. WASHROOM FLOOR PLAN TYP. 1 202 B.F. WASHROOM ELEVATION 'A' 1 203 B.F. WASHROOM ELEVATION 'B' 1 204 B.F. WASHROOM ELEVATION 'C' 1 205 B.F. WASHROOM ELEVATION 'D'

DOORDOOR

DOOR

DOORDOOR

DOORDOOR

L200D.02.200.2TYPE F9002100PAINT35SET 3n/a

L200D.02.200.2.1TYPE F9002100PAINT35SET 3n/a

L200D.02.200.2.2TYPE F9002100PAINT35SET 3n/a

L200D.02.200.3TYPE F9002100PAINT35SET 3n/a

L200D.02.200.6TYPE F9002100PAINT35SET 3n/a

L200D.02.201.1TYPE B18002700PAINT55SET 1n/a

L200D.02.201.2TYPE F9002100PAINT35SET 3n/a

L200D.02.201.5TYPE F9002100PAINT35SET 3n/a

L200D.02.201.6TYPE F9002100PAINT35SET 3n/a L200D.02.201.6.1TYPE F9002100PAINT35SET 3n/a L200D.02.201.6.2TYPE F9002100PAINT35SET 3n/a L200D.02.202.1TYPE B18002700PAINT55SET 1n/a

L200D.02.204.1TYPE A15102110PAINT32 32SET 290 Min. L200D.02.204.2TYPE A15102110PAINT32 32SET 290 Min. L200D.02.204.3TYPE B18002700PAINT112SET 1n/a L200D.02.204.4TYPE C9322150PAINT44SET 290 Min. L200D.02.204.4.1TYPE C9322150PAINT44SET 290 Min. L200D.02.204.5TYPE B18002700PAINT112SET 1n/a L200D.02.204.6TYPE A15102110PAINT32 32SET 290 Min. L200D.02.204.7TYPE A15102110PAINT32 32SET 290 Min. L200D.02.204.8TYPE C9322150PAINT44SET 290 Min. L200D.02.204.9TYPE B18002700PAINT112SET 1n/a L200D.02.204.10TYPE C9322150PAINT44SET 290 Min. L200D.02.204.11TYPE C9322150PAINT44SET 290 Min. L200D.02.204.12TYPE C9322150PAINT44SET 290 Min. L200D.02.204.13TYPE C9322150PAINT44SET 290 Min. L200D.02.204.14TYPE B18002700PAINT112SET 1n/a L200D.02.204.15TYPE C9322150PAINT44SET 290 Min. L200D.02.207.1TYPE B18002700PAINT55SET 1n/a L200D.02.207.1.1TYPE C9322150PAINT44SET 290 Min. L200D.02.208.1TYPE B18002700PAINT55SET 1n/a L200D.02.208.2TYPE F9002100PAINT35SET 3n/a L200D.02.208.2.1TYPE F9002100PAINT35SET 3n/a L200D.02.208.2.2TYPE F9002100PAINT35SET 3n/a L200D.02.208.3TYPE F9002100PAINT35SET 3n/a L200D.02.208.6TYPE F9002100PAINT35SET 3n/a L200D.02.209.2TYPE F9002100PAINT35SET 3n/a L200D.02.209.5TYPE F9002100PAINT35SET 3n/a L200D.02.209.6TYPE F9002100PAINT35SET 3n/a L200D.02.209.6.1TYPE F9002100PAINT35SET 3n/a L200D.02.209.6.2TYPE F9002100PAINT35SET 3n/a L200D.02.211.1.1TYPE B18002700PAINT55SET 1n/a L200D.02.211.1.2TYPE B18002700PAINT55SET 1n/a L200D.02.211.2TYPE C9322150PAINT44SET 290 Min. L200D.02.211.3TYPE C9322150PAINT44SET 290 Min. L200D.02.213.1TYPE C9322150PAINT44SET 290 Min. L200D.02.213.2TYPE C9322150PAINT44SET 290 Min. L200D.02.214.1TYPE B18002700PAINT55SET 1n/a L200D.02.214.1.1TYPE C9322150PAINT44SET 290 Min. L200D.02.214.1.2TYPE B18002700PAINT55SET 1n/a L200D.02.214.2TYPE C9322150PAINT44SET 290 Min.

LEVELMARK

L300-500D.03.300.2TYPE E8502100PAINT35 /SET 3n/a L300-500D.03.300.3TYPE E8502100PAINT35 /SET 3n/a L300-500D.03.300.4TYPE F9002100PAINT35 /SET 3n/a L300-500D.03.300.4.2TYPE G9002100PAINT35 /SET 1n/a L300-500D.03.300.6TYPE F9002100PAINT35 /SET 3n/a L300-500D.03.301.4TYPE F9002100PAINT35 /SET 3n/a L300-500D.03.301.5TYPE F9002100PAINT35 /SET 3n/a L300-500D.03.301.5.2TYPE G9002100PAINT35 /SET 1n/a L300-500D.03.302.2TYPE F9002100PAINT35 /SET 3n/a L300-500D.03.302.2.2TYPE G9002100PAINT35 /SET 1n/a L300-500D.03.302.3TYPE F9002100PAINT35 /SET 3n/a L300-500D.03.302.7TYPE G9002100PAINT35 /SET 1n/a L300-500D.03.303.6TYPE G9002100PAINT35 /SET 1n/a L300-500D.03.304.1TYPE A15102110PAINT32 32SET 290 Min. L300-500D.03.304.2TYPE A15102110PAINT32 32SET 290 Min. L300-500D.03.304.3TYPE A15102110PAINT32 32SET 290 Min. L300-500D.03.304.4TYPE C9322150PAINT44 /SET 290 Min. L300-500D.03.304.4-1TYPE C9322150PAINT44 /SET 290 Min. L300-500D.03.304.5TYPE A15102110PAINT32 32SET 290 Min. L300-500D.03.304.6TYPE A15102110PAINT32 32SET 290 Min. L300-500D.03.304.7TYPE A15102110PAINT32 32SET 290 Min. L300-500D.03.304.8TYPE C9322150PAINT44 /SET 290 Min. L300-500D.03.304.9TYPE A15102110PAINT32 32SET 290 Min. L300-500D.03.304.10TYPE A15102110PAINT32 32SET 290 Min. L300-500D.03.304.11TYPE A15102110PAINT32 32SET 290 Min. L300-500D.03.304.12TYPE A15102110PAINT32 32SET 290 Min. L300-500D.03.304.13TYPE C9322150PAINT44 /SET 290 Min. L300-500D.03.308.4TYPE F9002100PAINT35 /SET 3n/a L300-500D.03.308.5TYPE F9002100PAINT35 /SET 3n/a L300-500D.03.308.5.2TYPE G9002100PAINT35 /SET 1n/a L300-500D.03.308.6TYPE G9002100PAINT35 /SET 1n/a L300-500D.03.309.2TYPE F9002100PAINT35 /SET 3n/a L300-500D.03.309.2.2TYPE G9002100PAINT35 /SET 1n/a L300-500D.03.309.3TYPE F9002100PAINT35 /SET 3n/a L300-500D.03.309.7TYPE G9002100PAINT35 /SET 1n/a L300-500D.03.310.3TYPE F9002100PAINT35 /SET 3n/a L300-500D.03.310.5TYPE F9002100PAINT35 /SET 3n/a L300-500D.03.310.5.2TYPE G9002100PAINT35 /SET 1n/a L300-500D.03.310.6TYPE E8502100PAINT35 /SET 3n/a L300-500D.03.310.7TYPE E8502100PAINT35 /SET 3n/a L300-500D.03.312.2.2TYPE G9002100PAINT35 /SET 1n/a L300-500D.03.312.4TYPE F9002100PAINT35 /SET 3n/a L300-500D.03.312.5TYPE F9002100PAINT35 /SET 3n/a L300-500D.03.312.5.2TYPE G9002100PAINT35 /SET 1n/a L300-500D.03.312.6TYPE G9002100PAINT35 /SET 1n/a L300-500D.03.313.2TYPE F9002100PAINT35 /SET 3n/a L300-500D.03.313.3TYPE F9002100PAINT35 /SET 3n/a L300-500D.03.313.7TYPE G9002100PAINT35 /SET 1n/a L300-500D.03.314.4TYPE F9002100PAINT35 /SET 3n/a L300-500D.03.314.5TYPE F9002100PAINT35 /SET 3n/a L300-500D.03.314.5.2TYPE G9002100PAINT35 /SET 1n/a L300-500D.03.314.6TYPE G9002100PAINT35 /SET 1n/a L300-500D.03.315.2TYPE F9002100PAINT35 /SET 3n/a L300-500D.03.315.2.2TYPE G9002100PAINT35 /SET 1n/a L300-500D.03.315.3TYPE F9002100PAINT35 /SET 3n/a L300-500D.03.315.7TYPE G9002100PAINT35 /SET 1n/a

LEVELMARK

L600D.06.600.1TYPE B18002700PAINT112SET 1n/a L600D.06.600.2TYPE G9002100PAINT35SET 1n/a L600D.06.600.3TYPE G15002100PAINT35SET 1n/a L600D.06.601.1TYPE B18002700PAINT112SET 1n/a L600D.06.601.2TYPE G9002100PAINT35SET 1n/a L600D.06.601.3TYPE G15002100PAINT35SET 1n/a L600D.06.604.01TYPE A15102110PAINT32SET 290 Min. L600D.06.604.2TYPE A15102110PAINT32SET 290 Min. L600D.06.604.3TYPE C9322150PAINT44SET 290 Min. L600D.06.604.3.1TYPE C9322150PAINT44SET 290 Min. L600D.06.604.4TYPE A15102110PAINT32SET 290 Min. L600D.06.604.5TYPE A15102110PAINT32SET 290 Min. L600D.06.604.6TYPE C9322150PAINT44SET 290 Min. L600D.06.604.7TYPE A15102110PAINT32SET 290 Min. L600D.06.604.8TYPE A15102110PAINT32SET 290 Min. L600D.06.604.9TYPE C9322150PAINT44SET 290 Min. L600D.06.607.1TYPE B18002700PAINT112SET 1n/a L600D.06.607.5TYPE G15002100PAINT35SET 1n/a L600D.06.607.6TYPE G9002100PAINT35SET 1n/a L600D.06.608.1TYPE B18002700PAINT112SET 1n/a L600D.06.608.5TYPE G15002100PAINT35SET 1n/a L600D.06.608.6TYPE G9002100PAINT35SET 1n/a L600D.06.610.1TYPE B18002700PAINT112SET 1n/a L600D.06.610.2TYPE G9002100PAINT35SET 1n/a L600D.06.610.3TYPE G15002100PAINT35SET 1n/a L600D.06.612.1TYPE B18002700PAINT112SET 1n/a L600D.06.612.6TYPE G15002100PAINT35SET 1n/a L600D.06.612.7TYPE G9002100PAINT35SET 1n/a

DOOR SCHEDULE L700

DOORDOOR

SIZE FINISHWIDTHHEIGHT L700D.06.708.7TYPE F9002100PAINT35 /SET 3n/a L700D.06.708.9TYPE F9002100PAINT35 /SET 3n/a L700D.06.708.12TYPE F9002100PAINT35 /SET 3n/a L700D.06.708.14TYPE D8002100PAINT35 /SET 3n/a L700D.06.708.17TYPE F9002100PAINT35 /SET 3n/a L700D.06.708.19TYPE F9002100PAINT35 /SET 3n/a L700D.06.708.21TYPE F9002100PAINT35 /SET 3n/a L700D.06.708.22TYPE D8002100PAINT35 /SET 3n/a L700D.06.710.2TYPE D8002100PAINT35 /SET 3n/a L700D.06.710.3TYPE D8002100PAINT35 /SET 3n/a

FRAME THICKNES S HARDWAR E SET FIRE RATING COMMENT STYPE

LEVELMARK

DEVELOPMENTS

DUNDASSTREET WARNERDRIVE ALBANYSTREET ASHLAND AVENUEMcCORM I CK BLVD BUILDING LOCATION 293 717 250 593 257 1111567111 1788 876224496246 2706 5093250 1032 50 2125 2175 3877538 3882538 3887538 208738 850 2125 2125 900 950 2125 1580 2110 7550112518561975 75143075 1580 1121565112 1788 1032 5093250 208738208738 3877538 850 3882538 3887538 900 950 DOOR TYPE 'A'DOOR TYPE 'B'DOOR TYPE 'C'DOOR TYPE 'D'DOOR TYPE 'E'DOOR TYPE 'F' DOOR ELEVATION(SCALE 1:20) DOOR PLAN(SCALE 1:20) DOOR TYPE 'G' 2587525 925 2587525 925 SINGLE SWING DOUBLE DOOR MULTI -SLIDING GLASS PATIO DOOR FIRE RATED SINGLE SWING DOOR SINGLE SWING WOOD DOOR SINGLE SWING WOOD DOOR SINGLE SWING WOOD DOOR SINGLE POCKET DOOR 25 2100 2125 DOOR SCHEDULE NOTES GENERAL NOTES (APPLIES TO ALL DOORS) ALL DOORS IN A FIRE SEPERATIONS SHALL BE FIRE RATED. FIRE RESISTANCE RATING OF CLOSURE SHALL BE IN ACCORDANCE WITH OBC 3.1.8.4. FIRE PROTECTION RATING OF CLOSURE FIRE RESISTANCE RATING OF FIRE SEPERATION 30 MINUTES 20 MINUTES 45 MINUTES 45 MINUTES HOUR REQUIRED FIRE PROTECTION RATING OF CLOSURE 45 MINUTES 1.5 HOURS HOUR HOUR 1.5 HOURS ALL DOORS TO BE IN ACCORDANCE WITH THE LATEST EDITION OF THE ONTARIO BUILDING CODE (OBC) 2012 ALL DOORS IN A BARRIER FREE PATH OF TRAVEL SHALL HAVE A MINIMUM CLEAR OPENING OF 860mm WHILE IN THE OPEN POSITION. ALL DOORS IN A BARRIER FREE PATH OF TRAVEL IF NOT EQUIPPED WITH AN OPERATOR, 600mm CLEARANCE SHALL BE PROVIDED ON THE LATCH SIDE OF THE DOOR IF THE DOOR SWINGS TOWARDS THE APPROACH SIDE, A 300mm CLEARANCE SHALL BE PROVIDED ON THE LATCH SIDE OF THE DOOR SWINGS AWAY FROM THE APPROACH SIDE. ALL DOORS TO BE LOCATED 150mm FROM CORNER OF ADJACENT WALLS UNLESS NOTED OTHERWISE. CONTRACTOR TO CONTACT ARCHITECT IF DOOR LOCATION IS AT QUESTION. ALL DOOR HARDWARE TO BE IN ACCORDANCE WITH THE LATEST EDTION OF THE ONTARIO BUILDING CODE (OBC) 2012 REFER TO ROOM FINISH SCHEDULE FOR FINISH COLOURS AND TRIM DETAILS. ALL DOORS TO BE EQUIPPED WITH BARRIER FREE HARDWARE HARDWARE TO BE IN ACCORDANCE WITH OBC DOOR HARDWARE SET: SET 1: ENTRANCE ALUK STAINLESS STEEL DOOR HANDLE, HINGE, SINGLE POINT LOCK, KICK PLATE, DOOR VIEWER SET 2: FIRE RATED D&D STAINLESS STEEL FIRE RATED HINGE, DOOR CLOSER, PANIC EXIT DEVICE, SMOKE SEAL, MORTISE DOOR LOCK AND HANDLE SET 3: STANDARD ALUK STAINLESS STEEL DOOR HANDLE, KICK PLATE, DOOR VIEWER DRAWINGFILE CHECKEDDATE DRAWING TITLE REVISION PROJECT TITLE DRAWN KEY-PLAN & BUILDING FOOTPRINT: DATE NO.REVISIONBY REVISIONS School of Building Technology ARCHITECTURAL TECHNOLOGY PROJECT TITLE CLIENT: PROJECT LOCATION: PROJECT NORTH: MUNICIPAL ADDRESS 2017 WARNER DRIVE LONDON, ONTARIO. LEGAL DESCRIPTION LOT NO. 98-106, BLOCK NO. E&F, PLAN NO. 494 ZONING DESIGNATION LAND USE BYLAW -#### RS6 ABBREVATIONS: AFFABOVE FINISHED FLOOR AFGABOVE FINISHED GRADE BOFBOTTOM OF FOOTING BOTBOTTOM BFBARRIER FREE CBCATCH BASIN CIPCAST IN PLACE CLCENTRE LINE CMUCONCRETE MASONRY UNIT COCLEAN OUT CONCCONCRETE CONTCONTINOUS C/WCOMPLETE WITH DWGDRAWING EFEXHAUST FAN EXTEXTERIOR FDFLOOR DRAIN FDCFIRE DEPARTMENT CONNECTION FINFINISH FFLFINISHED FLOOR LEVEL FRRFIRE RESISTANT RATING FTGFOOTING GALVGALVANIZED GWBGYPSUM WALL BOARD HBHOSE BIB HDPEHIGH DENSITY POLYETHYLENE HSSHOLLOW STRUCTURAL STEEL HVACHEATING, VENTILATION & CONDITIONING INSULINSULATION INTINTERIOR LVLLAMINATED VENEER LUMBER MTLMETAL MINMINIMUM PN MAXMAXIMUM NICNOT IN CONTRACT O/CON CENTRE OBCONTARIO BUILDING CODE ROROUGH OPENING REINREINFORCED T/OTOP OF TYPTYPICAL WICWALK IN CLOSET W/CWATER CLOSET WWMWIRE WELDED MESH VESTVESTIBULE TN A900 DOOR LEGEND & SCHEDULES AD 04/24/2021 SKYSCAPE CONDOS S_SHAH 21W_WD 2017 WARNER DRIVE, LONDON, ON, N5W 4C5. EXBRIT
DOOR SCHEDULE L200 LEVELMARK
FRAME THICKNES S HARDWAR E SET FIRE RATING COMMENT STYPE SIZE FINISHWIDTHHEIGHT
DOOR SCHEDULE L300-500
FRAME THICKNES S HARDWAR E SET FIRE RATING COMMENT STYPE SIZE FINISHWIDTHHEIGHT
SCHEDULE L600
FRAME THICKNES S HARDWAR E SET FIRE RATING COMMENT STYPE SIZE FINISHWIDTHHEIGHT
PROPOSEDROOFTRUSSPLAN SCALE:1/8"=1'-0" CONVENTIONALROOFFRAMING PRE-ENGINEEREDGIRDERTRUSS PRE-ENGINEEREDCOMMONTRUSS BUILDINGEXTENTBELOW 1.ALLTHECOMMONTRUSSESARESPACEDAT24"O/CBYOTHERS. 2.ALLCOMMONRAFTERSTOBE2x8SPF#2@24"O/C. 3.ALLHIPANDVALLEYRAFERSTOBE2x10SPF#2. BUILDINGTECHNOLOGY FANSHAWE COLLEGE WINDMERE MODERN TOWNHOUSES ROOFTRUSS PLAN A-101.1 PRODUCED BY AN AUTODESK STUDENT VERSION VERSIONSTUDENTAUTODESKANBYPRODUCED PRODUCED BY AN AUTODESK STUDENT VERSION PRODUCEDBYANAUTODESKSTUDENTVERSION

SITEKEY-PLAN

SITEPLAN SCALE:1"=2'-0" WINDERMEREROAD CURBOFEXISTING2-LANEROAD CURBOFEXISTING2-LANEROAD CURBOFNEW4-LANEROAD CURBOFNEW4-LANEROAD EXISTINGSIDEWALKNEWCONC.SIDEWALK 51'-9" 118'-3" ROAD ALLOWANCE ARTERIAL 65'-0"34'-5 1/2" 41'-8" FUTURE WIDENINGROAD FUTURE WIDENINGROAD 34'-5 1/2" R12' R12' R39' R5' R5' R3' R3' MAIL-BOX DEPRESSEDCONC.CURB 8'-4" 13'-10" 29'-41/2" 6'H6'WSIMTEK DECORATIVEROCK PANELFENCE STOOP BRICK DRIVEWAY 18"x18" BRICKPAVERS 6'HIGH TREATEDPINE PRIVACYFENCE 27'-4" 3'-6" 9'-9" 9'-9" 3'-6"9'-9" 19'-9 1/2" 5' 6" 9'-01/2"8'-4" 15'-101/2" 6'-5"15'-101/2" 6'-5"15'-101/2" 3'-6" 6'-5" 15'-3" 15'-3" 8'-101/2"8'-9" 23'-6"23'-11/2" R3'-6" R2'-6" R3'-6" R2'-6" 8'-4" 13'-10" 27'-4" 10'-6" 4' 25'-10 1/2" 26'-41/2" 25'-1" 25'-91/2" 25'-61/2" 26'-41/2" 31'-3" 135° 135° 135° 135° 29'-3" 12'-6" 54'-31/2" 12'-6" 5' 4'-111/2"38'-8"27'-101/2"19'-21/2"4'-7" SIGNAGE DEPRESSEDCONC.CURB 6'H6'WSIMTEK DECORATIVEROCK PANELFENCE 6'H6'WSIMTEK DECORATIVEROCK PANELFENCE 6'H6'WSIMTEK DECORATIVEROCK PANELFENCE 6'H6'WSIMTEK DECORATIVEROCK PANELFENCE 6'H6'WSIMTEK DECORATIVEROCK PANELFENCE 9'-11" 21'-91/2" 14'-5" COBBLE STONE PAVERS 18"x18" COBBLE STONE PAVERS 18"x18" COBBLE STONE PAVERS 18"x18" COBBLE STONE PAVERS 18"x18" COBBLE STONE PAVERS R5' 23'-1" 15'-01/2" 6'HIGH TREATEDPINE PRIVACYFENCECOMPOSITEDECK STONETILE COMPOSITEDECK STONETILE COMPOSITEDECK STONETILE COMPOSITEDECK STONETILE COMPOSITEDECK STONETILE INTERLOCKING BRICK DRIVEWAY INTERLOCKING BRICK DRIVEWAY INTERLOCKING BRICK DRIVEWAY INTERLOCKING 3'-6"3'-6" STONETILE STOOP STONETILE STOOP STONETILE STOOP STONETILE STOOP STONETILE 6"CONC.CURB 6"CONC.CURB 6"CONC.CURB 6"CONC.CURB 6"CONC. CURB 6"CONC.CURB BUIDING SETBACK BUIDING SETBACK BUILDINGSETBACK BUILDINGSETBACK BUILDINGSETBACK ASPHALT ASPHALT S.O.D S.O.D S.O.D S.O.D S.O.D S.O.D S.O.D INTER-LOCKING 5'x3'BASEMENT WIN.OPENING ONDECK 5'x3'BASEMENT WIN.OPENING ONDECK 5'x3'BASEMENT WIN.OPENING ONDECK S.P S.P S.P S.P S.P S.PS.PS.PS.PS.PS.P S.P S.P S.PS.P S.P S.P S.P S.P ZONE LOTAREA SETBACKMIN. RESIDENTIALR-5 FRONTEXTERIORYARD REARYARD INTERIOR SETBACKMIN. COVERAGEMAX% LANDSCAPEMIN% HEIGHTMAX. FRONTAGEMIN. REQUIRED PROVIDED 21527.800 SQ.FT 26.246 FT 14.843 FT 9.840 FT 9.840 FT 30%6458.100SQ.FT 45%9687.100SQ.FT 39.370 FT 98.425 FT 27446.725 26.246 14.843 9.840 9.840 SQ.FT FT FT FT FT SQ.FT SQ.FT FT FT 6451.217 12206.445 22.700 142.920 LEGALDESCRIPTION: CON4PTLOT15RP33R6242PARTS1TO5 REGO.35AC84.42FR177.90D LEGENDS: NEWTREES 6'WOODFENCE
SCALE:N.T.S RIDGE RIDGE RIDGE HIPRIDGE VALLEY RIDGE RIDGE RIDGE RIDGE RIDGE VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY RIDGE HIPRIDGE RIDGE RIDGE VALLEYVALLEY RIDGE VALLEYVALLEY RIDGE VALLEYVALLEY SLOPE 4/12 SLOPE 4/12 SLOPE 4/12 SLOPE 4/12 SLOPE 4/12 SLOPE 4/12 SLOPE 4/12 SLOPE 4/12 SLOPE 4/12 SLOPE 4/12 SLOPE 4/12 SLOPE 4/12 SLOPE 4/12 SLOPE 4/12SLOPE 4/12 SLOPE 4/12 SLOPE 4/12 SLOPE 4/12 SLOPE 4/12 SLOPE 4/12 SLOPE5/12 SLOPE5/12 SLOPE5/12 5/12SLOPE SLOPE 4/12 SLOPE 4/12 SLOPE 4/12 SLOPE5/12 SLOPE5/12 5/12SLOPE SLOPE5/12 SLOPE4/12 SLOPE4/12 ROOFPLAN SCALE:3/32"=1'-0" RIDGE RIDGE ROOFVENT:PROVIDE1SQ.FT. FOREVERY300SQ.FT. OFINSULATEDBUILDINGAREA EAVESTROUGH EAVESTROUGHEAVESTROUGH EAVESTROUGHEAVESTROUGH EAVESTROUGHEAVESTROUGH EAVESTROUGH EAVESTROUGH SLOPE 3/12 SLOPE 3/12 VALLEY VALLEY EAVESTROUGH SLOPE 3/12 VALLEYROOFVENT:PROVIDE1SQ.FT. FOREVERY300SQ.FT. OFINSULATEDBUILDINGAREA WALLEXTENTBELOW COLUMNBELOW WALLEXTENTBELOW COLUMNBELOW VALLEY VALLEYVALLEY VALLEYVALLEY VALLEYVALLEY BUILDINGTECHNOLOGY FANSHAWE COLLEGE WINDMERE MODERN TOWNHOUSES SITEPLAN & ROOFPLAN A-101 PRODUCED BY AN AUTODESK STUDENT VERSION VERSIONSTUDENTAUTODESKANBYPRODUCED PRODUCED BY AN AUTODESK STUDENT VERSION PRODUCEDBYANAUTODESKSTUDENTVERSION
UP UP UP UP BLOCKFOUNDATIONPLAN SCALE:1/8"=1'-0" WEEPINGTILEONPERIMETER OFFOUNDATIONWALLS. MIN.Ø=100mm(9.14.3.2.(1)) WINDOWWELLCLEARANCE MIN.-550mm(9.9.10.1.(5)) 4"CONC.S.O.G 4"CONC.S.O.G SUMPPUMP 4"CONC.S.O.G 4"CONC.S.O.G WEEPINGTILEONPERIMETER OFFOUNDATIONWALLS. MIN.Ø=100mm(9.14.3.2.(1)) WEEPINGTILEONPERIMETER OFFOUNDATIONWALLS. MIN.Ø=100mm(9.14.3.2.(1)) 26'-2 WEEPINGTILEONPERIMETER OFFOUNDATIONWALLS. MIN.Ø=100mm(9.14.3.2.(1)) WEEPINGTILEONPERIMETER OFFOUNDATIONWALLS. MIN.Ø=100mm(9.14.3.2.(1)) 17'-1 8'-3 8'-3 7'-11 25'-10"4 17'-6" 17'-5" 3 7'-8 7'-10 26'-2 76'-7 26'-1 7'-10 7'-8 160'-1 41'-4 25'-9 25'-9 25'-8 41'-4 7'-11 6'-5 14'-4 4'-11 7'-8 8'-8 13'-1 5'-4 1'-11" 56'-1 WINDOWWELLCLEARANCE MIN.-550mm(9.9.10.1.(5)) WEEPINGTILEONPERIMETER OFFOUNDATIONWALLS. MIN.Ø=100mm(9.14.3.2.(1)) 8'-8 8'-8 15'-8 10'-1" 15'-8 10'-1" 15'-8 10'-1" 30'-7" 8'-8 8'-8 8'-88'-8 160'-1 7'-11 6'-5 14'-4 4'-11 7'-8 8'-8 13'-1 5'-4 1'-11" 56'-1 135° 135° 90° 135° 135° 90° 9"7'-10 10'-3" 14'-6" 8" 6'-3 6'-3 8"6'-3 6'-3 4'-7 8"6'-3 6'-2 8" 14'-6" 10'-3" 7'-10 9" 9" 7'-2 7'-2 9'-3 10'-9 8" 12'-2 9" 4'-8 8" 4"CONC.S.O.G 14'-9 2'-1" 9" 12'-5" 4'-10 8" 3'-8 5'-6 9"3'-11 6'-5 8" 9" 12'-5" 4'-10 8" 3'-8 5'-6 3'-11 6'-5 8" 9" 12'-5" 4'-10 8" 3'-8 5'-6 3'-11 6'-5 8" 4"CONC.S.O.G 9" 7'-2 7'-2 9'-3 10'-9 8" 12'-2 9" 4'-8 8" 4"CONC.S.O.G 14'-9 2'-1" 7'-114'-7 7'-11 4'-7 7'-11 8'-3" 1'-10" 9" 9" 8'-3" 1'-10" 7'-3" 7'-3" 7'-3" WINDOWWELL CLEARANCE MIN.-550mm (9.9.10.1.(5)) UP UP UP UP UP UP 2x6LOADBEARINGWALL 2x6LOADBEARINGWALL 2x6LOADBEARINGWALL 2x6LOADBEARINGWALL 2x6 LOAD BEARING WALL 2x6LOADBEARINGWALL 2x6 LOAD BEARING WALL 2x6LOADBEARINGWALL 2x6 LOAD BEARING WALL 2x6LOADBEARINGWALL 8'-3" 1'-10" ID SIE DESCRIPTION SUPPORTS 18"9"F-1 16"8" 16"8" (632632266)mm F-2 LB-1 F-3 9"CONC.FOUNDATION CONC.STRIPFOOTINGC/W INTEGRALKEWA 8"CONC.FOUNDATION 2x6WOODSTUDLOAD BEARINGWALL (866866383)mmF-4 WOODSTEELCOLUMN (C1C3UNITA) 6"6"WOODCOLUMN (C2-UNITB) CONC.STRIPFOOTINGC/W INTEGRALKEWA CONC.STRIPFOOTINGC/W INTEGRALKEWA ISOLATEDCONC.PAD FOOTING ISOLATEDCONC.PAD FOOTING NOTES: ALLTHEWINDOWOPENINGDIMENSIONSAREMEASUREDINCLUDINGTHE WINDOWFRAME. ABBREVATIONS: B#:BEAM BM:BEAMPOCKET CONC.:CONCRETE C/W:COMESWITH C#:COLUMN F#:FOOTING# J#:JOIST# LB#:LOAD-BEARINGFOOTING# O/C:ONCENTER WIN.:WINDOW BUILDINGTECHNOLOGY FANSHAWE COLLEGE WINDMERE MODERN TOWNHOUSES BLOCK FOUNDATION PLAN A-102 PRODUCED BY AN AUTODESK STUDENT VERSION VERSIONSTUDENTAUTODESKANBYPRODUCED PRODUCED BY AN AUTODESK STUDENT VERSION PRODUCEDBYANAUTODESKSTUDENTVERSION

55'-10 3/8"

4'-9 1/8" 7'-6 3/8" 8'-6 3/8" 12'-10 7/8" 7'-9 1/8"

5'-91/8"

11 1/4" 3'-1 1/2"

5'-91/8"

5'-13/4"

4'-41/2" 1'-45/8" 10'-107/8" 1'-11/4"

4'-107/8"5'-31/8"

9'-61/4"

6'-73/8"

2'-3" 23/4" 3'-2 1/2" 3'-2 1/2"

2'-15/8" 4'-113/8"

2'-101/2" 2'-6" 71/2" 3'-1" 4'-35/8"

JI-2X10 @16" O/C B1-W25024 JI-2X10 @16" O/C JI-2X10 @16" O/C JI-2X10 @16" O/C B1 B1B1 3'-0" X 7'-0" 5'-0" X 3'-0" RECESSED CONCRETETO SUITGRADE 4"CONC.S.O.G 14 RISERS UP @ 7.5" ARCHEDSTUDWALL ARCHEDSTUDWALL ARCHED STUD WALL ENGINEERED 5'-3"x5'-2" 4'-5"x5'-2"2-2x10HEADER 2-2x10HEADER 4'-5"x5'-2" 2-2x10HEADER 6'-1"x5'-2" ENGINEERED 11'-10"x5'-2" ENGINEERED6'-3"x5'-2" 2-2x10 HEADER5'-3"x5'-2" 2-2x10 HEADER5'-3"x5'-2" 4'-0" X 7'-0" 3'-0" X 7'-0" 3'-6" X 7'-0" 3'-0"x7'-0" 3'-0" X 7'-0" 3'-0"x7'-0" 2'-6"x7'-0" 2'-6"x7'-0" 2-2x10HEADER 2-2x10HEADER ENGINEERED ENGINEERED ENGINEERED ENGINEERED ENGINEERED ENGINEERED 2-2x10HEADER 9'-0"x7'-6"O/HGARAGEDOOR ENGINEEREDTILE ENGINEEREDTILE PLANKW/RIGIDCORE VINYLSHEET VINYLSHEET VINYLSHEET RIGIDCOREPLANK RIGIDCOREPLANK GORILLAGARAGEFLOOR ENGINEEREDTILE COMPOSITESTONETILE 8'-6"OPENINGHEIGHT 8'-6" OPENING HEIGHT 8'-6"OPENINGHT. RIGID CORE PLANK CLOSET CLOSET CLOSET BUILT-IN SEATW/ SHOERACK BELOW FIRSTFLOORPLAN-UNITA:1STOREY SCALE:1/4"=1'-0" BASEMENTFLOORPLAN-UNITA:1STOREY SCALE:1/4"=1'-0" 2-2x10 HEADER COMPOSITESTONETILE 14 RISERS DN @ 7.5" 27'-10" PRE-ENGINEEREDTRUSSES@24"O/C 38'-7"PRE-ENGINEERED TRUSSES @ 24" O/C 25'-6" PRE-ENGINEEREDTRUSSES@24"O/C 2-2x10HEADER 32"HT. GLASS RAILING 32"HT.GLASSRAILING PRE-ENGINEERED GIRDER TRUSS 2x6LOADBEARINGWALL 2x6LOADBEARINGWALL 2x6LOADBEARINGWALL FURNANCE HW 4'-01/4" 3'-101/2" 1'-9" 1'-9" 6'-63/4" 7'-61/2" 25'-45/8" 13/8" 40'-111/8" 1'-2" 24'-01/2" 1'-2" 2" 111/4" 24'-6" 111/4" 14'-6 1/2" 12'-0 1/4" 7'-10 3/8" 5 1/2" 20'-1" 5 1/2" 55'-5 1/8" 5'-45/8" 9'-27/8" 2'-91/4" 7'-6" 7'-6" 8'-71/2" 17'-43/4" 14'-105/8" 32'-43/4" 3'-7 1/2" 6'-3" 4'-6" 3'-4" 4'-2 1/4" 4'-2 1/4" 4'-4 1/8" 6'-8 1/8" 6'-2 3/4" 7'-9 1/8" 14'-4 1/2"
135° 135° 90° 2'-81/2"
2'-101/2" 2'-6"3'-85/8" 2'-111/8"
2'-111/8"31/4"
2'-53/8" 9'-101/4"
51/2" 81/2"
3'-01/8" 9"
2"
6'-3" 4'-8" 4'-5 1/2" 5'-0 3/4" 3'-4 1/2" 7'-7" 3'-8 1/2" 8'-10 3/4" 14'-0 1/2" 1'-4 1/2" 6'-9 5/8" 3'-10" 3'-0 1/2" 4'-9 7/8" 12'-9 1/8" 7'-3 3/8" 5 1/2" 11 1/4" 3/8" 4'-21/4"3'-4" 7'-103/4"7'-63/8" 105/8" 11'-0 1/8" 1'-5" 1'-5" 11'-9 7/8" 11'-9 7/8" 2'-11" 7'-10 1/2" 12'-10 3/8" 5'-5 7/8" 8" 7'-43/8" 6'-35/8" 7'-1" 5'-117/8" 13'-31/8" 8" 9'-53/8" 90° 90° 135° 135° 90° 135° 10'-101/4" 12'-31/4" 7'-81/8" 7'-103/4" 26'-21/2" 41'-47/8" 41/2" 41'-93/8" 7" 25'-21/2" 7" 9'-2 1/2" 7'-11 1/4" 6'-5 1/4" 4'-11 5/8" 7'-8 1/8" 8'-8 1/8" 13'-1 3/8" 5'-4 7/8" 1'-11" 14'-4 1/2" 56'-1 5/8" 33'-11 1/8" 8" 20'-0 1/2" 9" 9" 8'-81/8" 8'-81/4" 8'-81/2" 7'-111/4" 41/2" 7'-91/4" 41'-47/8" 41'-93/8" 56'-1 5/8" 9" 4'-8 7/8" 2'-7" 1' ATTICHATCHINSULATION ABOVE.MIN.600mm HEIGHTCLEARANCE BUILDINGTECHNOLOGY FANSHAWE COLLEGE WINDMERE MODERN TOWNHOUSES UNITPLAN UNIT-A 1STOREY A-103 PRODUCED BY AN AUTODESK STUDENT VERSION VERSIONSTUDENTAUTODESKANBYPRODUCED PRODUCED BY AN AUTODESK STUDENT VERSION PRODUCEDBYANAUTODESKSTUDENTVERSION
FIRSTFLOORPLAN-UNITB:2STOREY SCALE:1/4"=1'-0" B2: W 200 X 21 4"CONC.S.O.G JI-2X10@16"O/C B2B2 B2 B1 B1 B1:W25024 JI-2X10@16"O/C JI JI JI 2x6LOAD BEARINGWALL 3'-0" X 7'-0" 5'-0"3'-0" RECESSED CONCRETETO SUITGRADE 2x6 LOADBEARING WALL ARCHEDSTUDWALL ARCHEDSTUDWALL ENGINEERED 2'-0"x14'-11" 2'-0"x14'-11" 5'-7"x5'-2" 6'-1"x5'-2" ENGINEERED 11'-10"x5'-2" 5'-9"x5'-2" 2'-10"x5'-2" ENGINEERED 5'-9"x5'-2"2'-10"x5'-2" 4'-0" X 7'-0" 3'-0" X 7'-0" 3'-6" X 7'-0" 2'-6"x7'-0" HIGHBREAKFASTTABLE ENGINEERED ENGINEERED ENGINEERED 3'-0" X 7'-0" ENGINEERED 3'-0" X 7'-0" ENGINEERED2'-6"x7'-0"2'-6"x7'-0"ENGINEERED 2-2x10HEADER 9'-0"x7'-6"O/HGARAGEDOOR 3'-0"x7'-0" ENGINEERED RIGIDCOREPLANK RIGIDCOREPLANKRIGIDCOREPLANK FLEXSTEP VINYLSHEET FLEXSTEP RIGIDCORE PLANK RIGIDCOREPLANK ENGINEEREDTILEENGINEEREDTILE VINYLSHEET PLANKW/RIGIDCORE COMPOSITEDECKTILE GORILLAGARAGEFLOOR ENGINEEREDTILE COMPOSITEDECKTILE 8'-6"OPENINGHT. 8'-6"OPENINGHEIGHT 8'-6" OPENING HEIGHT CLOSET CLOSET CLOSET CLOSET CLOSET SECONDFLOORPLAN-UNITB:2STOREY SCALE:1/4"=1'-0" BASEMENTFLOORPLAN-UNITB:2STOREY SCALE:1/4"=1'-0" 2-2x10HEADER RONA COMPOSITEDECKTILE B2: W 200 X 21 JI-2X10@16"O/C B2 B2 B2 B1 B1 B1 JI-2X10@16"O/C JI JI J5-2X10@12"O/C J5 ENGINEEREDBEAM 2-2x10HEADER 37'-8"PRE-ENGINEERED TRUSSES @ 24" O/C 17-11" PRE-ENGINEEREDTRUSSES@24"O/C ENGINEERED ENGINEEREDENGINEERED ENGINEERED ENGINEERED BEAMB1 ENGINEEREDENGINEEREDENGINEEREDENGINEERED ENGINEERED 16 RISERS DN @ 7.5"16 RISERS UP @ 7.5" 14 RISERS DN @ 7.5" 14 RISERS UP @ 7.5" 14 RISERS UP @ 7.5" FURNANCE HW 32"HT. GLASS RAILING 32"HT.GLASSRAILING ROOFEXTENTABOVE ROOFEXTENTABOVE 51/2" 5'-21/4" 8'-33/4" 8'-3" 41/8" 25'-91/2" 1/2" 4'-41/8" 31/2" 26'-53/4" 5 1/2" 13'-0 1/2" 11'-10" 5 1/2" 20'-1" 5 1/2" 46'-4" 5 1/2" 13'-0 1/2" 4'-4 1/2" 4'-4 1/2" 5'-2" 4'-1" 5 1/2" 9'-0 1/2" 4'-10 3/4" 31'-11 1/2" 14'-4 1/2" 46'-4" 61/8" 2'-0" 5'-7" 2'-91/4" 7'-6" 7'-6" 1/2" 10'-103/8" 14'-105/8" 13/8" 25'-103/8" JI 6'-5" 2" 11 1/4" 13'-1 3/4" 2'-1 3/4" 9'-6 1/2" 6'-2" 4'-11/8" 2'-51/8" 3'-105/8" 2'-4" 12'-25/8" 6'-117/8" 3'-83/4" 1'-105/8" 11'-31/8" 1'-11/4" 10'-85/8" 14'-27/8" 51/2" 3'-6" 4'-81/8" 7'-71/8" 4'-81/8" 4'-107/8" 31/2" 1" 31/2" 41/8" 25'-91/2" 4" 26'-53/4" 5 1/2" 8'-11 1/4" 46'-6 1/2" 2'-1 5/8" 6'-4 1/8" 3'-0 1/2" 6'-3 5/8" 13'-5" 5 1/2" 5'-5 3/8" 5 1/2" 13'-0 1/2" 4'-4 1/2" 4'-4" 5'-3" 4'-0 1/2" 5 1/2" 5'-5 3/8" 31'-11 1/2" 9'-1 5/8" 46'-6 1/2" 6'-91/4" 4'-15/8" 3'-81/4" 3'-33/4" 7'-03/4" 6'-23/8" 61/8" 5'-3" 7'-71/2" 3'-1" 2'-33/4" 1'-11/8" 2'-113/8" 4'-21/8" 5'-101/2" 3'-113/4" 1'-6"9" 5'-71/2" 51/2" 2'-15/8" 4'-51/2" 3'-93/4" 7'-61/8" 7'-57/8" 1/2" 25'-9" 13/8" 25'-103/8" 11'-0 1/8" 1'-5" 1'-5" 17'-11/2" 7'-115/8" 4"41/2" 25'-91/2" 7'-6 1/2" 3'-11" 13'-4 1/2" 7'-2 1/2" 7'-2" 9" 6'-31/4" 4'-73/8" 14'-27/8" 3'-8 1/2" 5'-6 1/2" 3'-11 1/2" 1" 6'-4" 4'-73/4" 6'-27/8" 10'-10" 8'-3" 1'-10" 14'-111/2" 15'-81/2" 9" 25'-91/2" 41/2"41/2" 26'-61/2" 13'-7 1/2" 3'-2" HIGH WALL 8" 9" 24'-10" 8" 20'-0 1/2" 9" 47'-0 1/2" 6'-5 1/2" 2'-0"7" ATTICHATCH INSULATION ABOVE.MIN. 600mmHT. CLEARANCE BUILDINGTECHNOLOGY FANSHAWE COLLEGE WINDMERE MODERN TOWNHOUSES UNITPLAN UNIT-B 2STOREY A-104 PRODUCED BY AN AUTODESK STUDENT VERSION VERSIONSTUDENTAUTODESKANBYPRODUCED PRODUCED BY AN AUTODESK STUDENT VERSION PRODUCEDBYANAUTODESKSTUDENTVERSION

U/SFIRSTFLOORCEILING-UNIT:A

T/OFIRSTFLOOR-UNIT:A

T/0BASEMENTSLAB-UNIT:A

WOODCOL.W/

SIDEELEVATION

HARDIEPANEL

U/SSECONDFLOORCEILING-UNIT:B

T/0SECONDFLOOR-UNIT:B

T/OFIRSTFLOOR-UNIT:B

4'DEEPGARAGEFOOTING

T/0BASEMENTSLAB-UNIT:B

4'DEEPGARAGEFOOTING

T/0SECONDFLOOR-UNIT:B

FRONTPORCHELEVATION:UNIT-B

HARDIEPANEL VERTICALSIDING ALUM.EAVESTROUGH CERTAINTEEDASPHALTSHINGLES PRE-FINISHEDALUM. SLIDINGWINDOW RONASTONESLOPEDSILL ARRISCRAFTSTONE VENNERCLADDING ASPHALTSHINGLES MAX.ANGLEOF REPOSEFOR STEPPED FOOTINGIS45° 4'DEEPGARAGEFOOTING 4' 7'-0" 5'-3"4'-5" 5'-2 5'-2 9'-0" 7'-6" DOWN-SPOUT 9'-0" 7'-6" 9'-0" 7'-6" 9'-0" 7'-6" 9'-0" 7'-6" 4'-0" 7'-0" 4' 7'-0" 4'-0" 7'-0" 4'-0" 7'-0" 5'-3" 4'-5" 5'-25'-2 9"FOUNDATIONWALL 4'DEEPGARAGEFOOTING 4'-0" 4'-0" 4'-0" 4'-0" ASPHALTSHINGLES ASPHALTSHINGLES ASPHALTSHINGLES HARDIEPANEL VERTICALSIDING ALUM.EAVESTROUGH CERTAINTEEDASPHALTSHINGLES PRE-FINISHEDALUM. SLIDINGWINDOW RONASTONESLOPEDSILL ARRISCRAFTSTONE VENNERCLADDING DOWN-SPOUT 9"FOUNDATIONWALL VERT.SIDING VERT.SIDING VERT.SIDING VERT. SIDING VERT. SIDING VERT. SIDING GLASSRAILING-3'2"HT. 8'-10 6'-10 FIXEDFROSTEDGLASS GLASSRAILING-3'2"HT. FIXEDFROSTEDGLASS DECORATIVEGLASS CLADDEDONWALL DECORATIVEGLASS CLADDEDONWALL 8'-9" 10'-0" 8'-0" U/SSECONDFLOORCEILING-UNIT:B ELEV.+18'-0" T/0SECONDFLOOR-UNIT:B ELEV.+10'-0" T/OFIRSTFLOOR-UNIT:B ELEV.+0'-0" T/0BASEMENTSLAB-UNIT:B ELEV.-8'-9" 4:12HIPROOF 4:12HIPROOF 5:12GABLEROOF 8'-9" 9'-0" U/SFIRSTFLOORCEILING-UNIT:E ELEV.+9'-0" T/OFIRSTFLOOR-UNIT:E ELEV.+0'-0" T/0BASEMENTSLAB-UNIT:E ELEV.-8'-9" 2' 5'-7" 3'-3 2' 5'-7" 3'-3 8'-2" 2' 5'-7" 3'-3 " 8'-2" ROOFVENT GRADEC/W2%SLOPE GRADEC/W2%SLOPE WOODCOL. W/STONE CLADDING WOODCOL. W/STONE CLADDING WOODCOL. W/STONE CLADDING WOODCOL. W/STONE CLADDING 2' 2' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 2' 2' 2' SOUTHELEVATION SCALE:1/8"=1'-0" 6'-8 6'-8 32° 32° 8'-10 6'-10 8'-10 6'-10 12 412 4 5:12GABLEROOF 4:12GABLEROOF 4:12GABLEROOF 12 412 4 12 4 12 4 12 4 12 4 12 4 12 6"6"6"6"6" 5'-3" 5'-2 5'-3" 5'-2 4'-5" 5'-2 6'-3"4'-5"2' 2' 2' 2' 2' 2'2'2' VERT.SIDING VERT.SIDING ASPHALTSHINGLES ASPHALTSHINGLES 5'-1 MAX.ANGLEOFREPOSEFOR STEPPEDFOOTINGIS45°
VERTICALSIDING ALUM.EAVESTROUGH CERTAINTEED ASPHALTSHINGLES PRE-FINISHEDALUM. SLIDINGWINDOW RONASTONESLOPEDSILL ARRISCRAFTSTONE VENNERCLADDING WOODCOL.W/ STONECLADDING 9"FOUNDATIONWALL HARDIEPANEL VERTICALSIDING ALUM.EAVESTROUGH CERTAINTEED ASPHALTSHINGLES PRE-FINISHEDALUM. SLIDINGWINDOW RONASTONE SLOPEDSILL ARRISCRAFTSTONE VENNERCLADDING
STONECLADDING GRADEC/W2%SLOPE WOODCOL.W/ STONECLADDING WOODCOL. PADFOOTING 6" 8'-9" 10'-0" 8'-0"
ELEV.+18'-0"
ELEV.+10'-0"
ELEV.+0'-0"
ELEV.-8'-9" 8'-9" 9'-0"
ELEV.+9'-0"
ELEV.+0'-0"
ELEV.-8'-9" 4:12GABLEROOF 3'-0" 5'-0"
SCALE:1/8"=1'-0" 2'2' 5'-1 MAX.ANGLEOFREPOSEFOR STEPPEDFOOTINGIS45°
HARDIEPANEL VERTICALSIDING PRE-FINISHEDALUM. SLIDINGWINDOW RONASTONESLOPEDSILL ARRISCRAFTSTONE VENNERCLADDING WOODCOL.W/ STONECLADDING 8'-9" 10'-0 8'-0" U/SSECONDFLOORCEILING-UNIT:B ELEV.+18'-0"
ELEV.+10'-0" T/OFIRSTFLOOR-UNIT:B ELEV.+0'-0" T/0BASEMENTSLAB-UNIT:B ELEV.-8'-9" 4:12SHEDROOF 4'-3 GLASSRAILING-3'2"HT. DOWN-SPOUT WOODPOSTS ASPHALTSHINGLES GRANITESTONESTEPS VERTICALSIDING VERTICALSIDING CERTAINTEED ASPHALTSHINGLES WOODPOST 16°32°
SCALE:1/8"=1'-0" 9"FOUNDATIONWALL GRADEC/W2%SLOPE 9"FOUNDATIONWALL GRADEC/W2%SLOPE 12 5 12 5 12 5 12 4 12 12 4 4:12GABLEROOF 4:12GABLEROOF 6" 6" 5'-2 4'-5" 6'-2 3'-6" 11'-10 5'-2 7'-0" 5'-2 2' 2'1' 2' 5'-9 2'-10 4'-3 5'-92'-10 4'-3 11'-10 3'-6" 6'-1 5'-2 5'-27'-0" 5'-9 2'-10 4'-3 5'-92'-10 4'-3 11'-10 3'-6" 6'-1 5'-2 5'-27'-0" 5'-9 2'-10 4'-3 5'-92'-10 4'-3 11'-10 3'-6" 6'-1 5'-2 5'-27'-0" 2' 2' 6'-23'-6"11'-10 5'-27'-0"5'-2 2'2' 4'-5" 1'2' 5'-2 12 4 12 5 12 5 ASPHALTSHINGLES FIXEDFROSTEDGLASS ASPHALTSHINGLES ASPHALTSHINGLESASPHALTSHINGLES VERT.SIDING VERT.SIDING VERT.SIDING VERT.SIDING VERT.SIDING FIXEDFROSTEDGLASSFIXEDFROSTEDGLASS HARDIEPANEL VERTICALSIDING ALUM.EAVESTROUGH CERTAINTEED ASPHALTSHINGLES PRE-FINISHEDALUM. SLIDINGWINDOW RONASTONESLOPEDSILL ARRISCRAFTSTONE VENNERCLADDING DOWN-SPOUT 9"FOUNDATIONWALL 8'-9" 10'-0" 8'-0" U/SSECONDFLOORCEILING-UNIT:E ELEV.+18'-0" T/0SECONDFLOOR-UNIT:E ELEV.+10'-0" T/OFIRSTFLOOR-UNIT:E ELEV.+0'-0" T/0BASEMENTSLAB-UNIT:E ELEV.-8'-9" GRADEC/W2%SLOPE NORTHELEVATION SCALE:1/8"=1'-0" HARDIEPANEL VERTICALSIDING ALUM.EAVESTROUGH CERTAINTEEDASPHALTSHINGLES PRE-FINISHEDALUM. SLIDINGWINDOW RONASTONESLOPEDSILL ARRISCRAFTSTONE VENNERCLADDING DOWN-SPOUT 9"FOUNDATIONWALL 8'-9" 9'-0" U/SFIRSTFLOORCEILING-UNIT:E ELEV.+9'-0" T/OFIRSTFLOOR-UNIT:E ELEV.+0'-0" T/0BASEMENTSLAB-UNIT:E ELEV.-8'-9" GRADEC/W2%SLOPE ROOFVENT WOODCOL. PADFOOTINGWOODCOL. PADFOOTING 3'-0" 5'-0" 3'-0" 5'-0" 3'-0" 5'-0" 12 4 12 4 12 4 12 4 12 4 12 12 12 4 12 4 4:12GABLEROOF 4:12GABLEROOF 5:12GABLEROOF5:12GABLEROOF BUILDINGTECHNOLOGY FANSHAWE COLLEGE WINDMERE MODERN TOWNHOUSES ELEVATIONS A-105 PRODUCED BY AN AUTODESK STUDENT VERSION VERSIONSTUDENTAUTODESKANBYPRODUCED PRODUCED BY AN AUTODESK STUDENT VERSION PRODUCEDBYANAUTODESKSTUDENTVERSION

TYP.VERTICALSIDINGCONSTRUCTION HARDIPANELVERTICALSIDINGPANEL 2x4WOODFURRING R-5RIGIDINSULATIONBOARD HOUSE-WRAP 2x6STUDC/WR-20BATTINSULATION 6MILPOLYVAPOURBARRIER 1/2"GYPSUMWALLBOARD

2x6STUDTOPPLATE 2-2x10WOODLINTELC/WRIGIDINSULATION

TYP.2x4INTERIORWALL-SOUNDINSULATED

PELLAFIBERGLASSSLIDINGWINDOW

TYP.SECONDFLOORCONSTRUCTION 1/2"GYPSUMWALLBOARD 2x10FLOORJOISTC/WSOLIDBLOCKING 5/8"T&GPLYWOODSHEATHINGSCREWEDANDGLUED

R-22BATTINSULATIONC/W 6MIL.POLYVAPOURBARRIER 2x10HEADER

PELLAFIBERGLASSSLIDINGWINDOW

TYP.SECONDFLOORCEILINGCONSTRUCTION 1/2"GYPSUMWALLBOARD 6MIL.POLYVAPOURBARRIER ENGINEEREDROOFTRUSS@24"O/C C/WR-60INSULATION

4:12SLOPEDGABLEROOF WITH6"RAKEINELEVATION

TYP.STONEVENEERWALLCONSTRUCTION

STONEVENEERCLADDING 1"AIRSPACE R-5RIGIDINSULATIONBOARD HOUSE-WRAP 2x6STUDC/WR-20BATTINSULATION 6MILPOLYVAPOURBARRIER 1/2"GYPSUMWALLBOARD

TYP.2x4INTERIORWALL-SOUNDINSULATED 1/2"GYPSUMWALLBOARD 2x4STUDWALLC/WSOUNDINSULATION 1/2"GYPSUMWALLBOARD

TYP.FIRSTFLOORCONSTRUCTION 5/8"T&GPLYWOODSHEATHINGSCREWEDANDGLUED 2x10FLOORJOISTC/WSOLIDBLOCKING

2x4SILLPLATEC/WANCHOR BOLTANDSILLGASKET

STONESETWITHMORTAR

4"ØWEEPINGTILEWITHFILTERFABRIC SOCK,ALSOC/W3/4"CRUSEDSTONE 6"MIN.GRANULARDRAINAGE.

TYP.FOUNDATIONWALLCONST. 6MIL.POLYVAPOURBARRIER R-20BATTINSULATION HOUSE-WRAP 9"CASTINPLACECONC.FOUNDATION DAMP-PROOFINGLAYER DRAINAGELAYER

TYP.2x4INTERIORWALL

2x4STUDWALL 1/2"GYPSUMWALLBOARD

TYP.BASEMENTFLOORCONSTRUCTION 4"CASTINPLACECONCRETESLAB 6MIL.POLYVAPOURBARRIER 4"MIN.COMPACTEDGRANULARFILL

18"DEEPx2"THICKGRANITE STONESETWITHMORTAR

2X6WOODPOSTINELEVATION

PRE-FINISHEDALUMINIUM SLIDINGWINDOWINELEVATION

BALCONYWITHGLASS RAILINGINELEVATION

SCUPPER

9"X18"CASTINPLACECONCRETE FOOTINGC/WCONTINOUSKEYWAY

4"ØWEEPINGTILEWITHFILTERFABRIC SOCK,ALSOC/W3/4"CRUSEDSTONE 6"MIN.GRANULARDRAINAGE.

TYP.VERTICALSIDINGINELEVATION

TYP.STONESILLINELEVATION

TYP.STONEVENEERINELEVATION

DOWN-SPOUT

GRADEC/W2MIN.SLOPE

8'-9" 10'-0" 8'-0" 2'-0" 1'-8" 6" SCALE:1/4"=1'-0" BUILDINGSECTION TYP.VERTICALSIDINGCONSTRUCTION TYP.SECONDFLOORCEILINGCONSTRUCTION TYP.ROOFCONSTRUCTION TYP.FOUNDATIONWALLCONSTRUCTION TYP.VERTICALSIDINGCONSTRUCTION 12 4 124 ELEV.-8'-9" T/OBASEMENTSLAB-UNIT:B ELEV.+0'-0" T/OFIRSTFLOOR:UNIT-B ELEV.+10'-0" T/OSECONDFLOOR:UNIT-B ELEV.+18'-0" U/SSECONDFLOORCEILING:UNIT-B 1'-8" 6" 3'-2" 3'-2" 3'-2" 3'-0"x7'-0"2'-8"x7'-0" 2'-8"x7'-0" 3'-2" 2'-0" TYP.STONEVENEERWALLCONSTRUCTION 91/2" 7 1/2" 2'-0" 4'-5"x2'-7" ELEV.+8'-6" T/OFRONTPORCHCANOPY:UNIT-B 9"X18"CASTINPLACECONCRETE FOOTINGC/WCONTINOUSKEYWAY
18"DEEPx2"THICKGRANITE
2x6STUDTOPPLATE 2-2x10WOODLINTELC/WRIGIDINSULATION
PELLAFIBERGLASS FIXEDGLASSWINDOW 2x6STUDTOPPLATE 2-2x10WOODLINTEL C/WRIGIDINSULATION
4:12SHEDROOF INELEVATION
1/2"GYPSUMWALLBOARD
1/2"NOSING ROOFVENTSNOTE: THEUNOBSTRUCTEDVENTAREASHALLNOTBELESSTHAN 1/300OFTHEINSULATEDCEILINGAREA9.19.1.2.1 7'-11 1/2" MIN. HEADROOM CLEARANCE 6'-3" ROOFVENTSNOTE: THEUNOBSTRUCTEDVENTAREASHALLNOTBELESSTHAN1/300OFTHE INSULATEDCEILINGAREA9.19.1.2.1 BUILDINGTECHNOLOGY FANSHAWE COLLEGE WINDMERE MODERN TOWNHOUSES BUILDING SECTION A-106 PRODUCED BY AN AUTODESK STUDENT VERSION VERSIONSTUDENTAUTODESKANBYPRODUCED PRODUCED BY AN AUTODESK STUDENT VERSION PRODUCEDBYANAUTODESKSTUDENTVERSION

ALLTHEWINDOWDOOROPENINGDIMENSIONSAREMEASUREDINCLUDING THEWINDOWDOORFRAME.

HEADROOMCLEARANCESHOULDBE6.89'(2100mm)OVERATLEAAST75% OFTHEBASEMENTAREAEXCEPTTHATUNDERBEAMSANDDUCTSTHE CLEARANCEISPERMITTEDTOBEREDUCEDTO6.4'(1950mm).

ABBREVATIONS: BP:BEAMPOCKET CONC.:CONCRETE C/W:COMESWITH O/C:ONCENTER

2x6 LOAD BEARING WALL 2'-0"x14'-11" 2'-0"x14'-11" CLOSET BASEMENTSTAIRPLAN-UNITB:2STOREY SCALE:1/2"=1'-0" 16RISERSDN@7.5" 16RISERSUP@7.5" 14RISERSDN@7.5" 14RISERSUP@7.5" 14RISERSUP@7.5" FIRSTFLOORSTAIRPLAN-UNITB:2STOREY SCALE:1/2"=1'-0" SECONDFLOORSTAIRPLAN-UNITB:2STOREY SCALE:1/2"=1'-0" 32"HT.GLASSRAILING 4'-0" 4'-0" 8'-9" 10'-0" 8'-0" TYP.FOUNDATIONWALLCONSTRUCTION 12 4 ELEV.-8'-9" T/OBASEMENTSLAB-UNIT:B ELEV.+0'-0" T/OFIRSTFLOOR:UNIT-B ELEV.+10'-0" T/OSECONDFLOOR:UNIT-B ELEV.+18'-0" U/SSECONDFLOORCEILING:UNIT-B 3'-2" ALUMINIUM HANDRAIL HEIGHT 3'-2" ALUMINIUM HANDRAIL HEIGHT 3'-0"x7'-0" 2'-0" 91/2" 7 1/2" TYP.STONEVENNERWALLCONSTRUCTION 2x6STUDTOPPLATE 2-2x10WOODLINTEL C/WRIGIDINSULATION TYP.SECONDFLOORCEILINGCONSTRUCTION TYP.VERTCALSIDINGWALLCONSTRUCTIONTYP.2x4INTERIORWALL-SOUNDBATTINSULATED TYP.2x4INTERIORWALL-SOUNDBATTINSULATED 1/2"NOSING 3'-2" GLASS RAILING HEIGHT 7'-6"HEADROOM CLEARANCE 6'-8 3/4" HEADROOM CLEARANCE 6'-10"HEADROOM CLEARANCE 9"18"CASTINPLACECONCRETE FOOTINGC/WCONTINOUSKEYWAY 4"ØWEEPINGTILEWITHFILTERFABRIC SOCK,ALSOC/W3/4"CRUSEDSTONE 6"MIN.GRANULARDRAINAGE. PELLAFIBERGLASS FIXEDGLASSWINDOW TYP.BASEMENTFLOORCONSTRUCTION 4"CASTINPLACECONCRETESLAB 6MIL.POLYVAPOURBARRIER 4"MIN.COMPACTEDGRANULARFILL TYP.SECONDFLOORCEILINGCONSTRUCTION 1/2"GYPSUMWALLBOARD 6MIL.POLYVAPOURBARRIER ENGINEEREDROOFTRUSS@24"O/C C/WR-60INSULATION TYP.2x4INTERIORWALL 1/2"GYPSUMWALLBOARD 2x4STUDWALL 1/2"GYPSUMWALLBOARD ROOFVENTSNOTE: THEUNOBSTRUCTEDVENTAREASHALLNOTBELESSTHAN 1/300OFTHEINSULATEDCEILINGAREA(9.19.1.2.(1)) BASEMENTSTAIRSECTION SCALE:1/2"=1'-0" 2-2x10JOISTC/W JOISTHANGERS 2-2x4TOPPLATES WOODPOST 2-2x10JOISTC/W JOISTHANGERS 2-2x4TOPPLATES WOODPOST 6'-10"HEADROOM CLEARANCE NOTES:
WIN.:WINDOW BUILDINGTECHNOLOGY FANSHAWE COLLEGE WINDMERE MODERN TOWNHOUSES STAIR PLAN& SECTION A-107 PRODUCED BY AN AUTODESK STUDENT VERSION VERSIONSTUDENTAUTODESKANBYPRODUCED PRODUCED BY AN AUTODESK STUDENT VERSION PRODUCEDBYANAUTODESKSTUDENTVERSION

TYP.VERTICALSIDINGCONSTRUCTION

HARDIPANELVERTICALSIDINGPANEL 2x4WOODFURRING R-5RIGIDINSULATIONBOARD HOUSE-WRAP 2x6STUDC/WR-20BATTINSULATION 6MILPOLYVAPOURBARRIER 1/2"GYPSUMWALLBOARD

TYP.ROOFCONSTRUCTION

ROOFSHEATHINGC/WWOODFURRING ENGINEEREDWOODTRUSS@24"O/C

TYP.ROOFCONSTRUCTION ASPHALTSHINGLES ROOFUNDERLAYMENT ROOFSHEATHINGC/WWOODFURRING ENGINEEREDWOODTRUSS@24"O/C

TYP.VERTICALSIDINGCONSTRUCTION HARDIPANELVERTICALSIDINGPANEL 2x4WOODFURRING R-5RIGIDINSULATIONBOARD HOUSE-WRAP 2x6STUDC/WR-20BATTINSULATION 6MILPOLYVAPOURBARRIER 1/2"GYPSUMWALLBOARD

TYP.SECONDFLOORCEILINGCONSTRUCTION 1/2"GYPSUMWALLBOARD MIL.POLYVAPOURBARRIER ENGINEEREDROOFTRUSS@24"O/CC/WR-60INSULATION

2-2x10WOODLINTELC/WRIGIDINSULATION

2x6STUDTOPPLATE

MDFWINDOWFRAMEEXTENSION

ALUMINIUMFLASHING

HARDIPANELVERTICALSIDINGBEYOND

PELLAFIBERGLASSSLIDINGWINDOW

MDFWINDOWEXTENSIONBEYOND

INSULATEAROUNDWINDOWFRAMESEAL VAPOURBARRIERTOWINDOWFRAME MDFWINDOWFRAMEEXTENSION

TYP.SECONDFLOORCONSTRUCTION 1/2"GYPSUMWALLBOARD 2x10FLOORJOISTC/WSOLIDBLOCKING 5/8"T&GPLYWOODSHEATHINGSCREWEDANDGLUED

R-22BATTINSULATIONC/W6 MIL.POLYVAPOURBARRIER 2x10HEADER

2-2x10WOODLINTELC/WRIGIDINSULATION

2x6STUDTOPPLATE

PELLAFIBERGLASSSLIDINGWINDOW HARDIPANELVERTICALSIDINGBEYOND ALUMINIUMFLASHING MDFWINDOWFRAMEEXTENSION

MDFWINDOWEXTENSIONBEYOND

TYP.STONEVENEERWALLCONSTRUCTION

STONEVENEERCLADDING 1"AIRSPACE R-5RIGIDINSULATIONBOARD HOUSE-WRAP

2x6STUDC/WR-20BATTINSULATION 6MILPOLYVAPOURBARRIER 1/2"GYPSUMWALLBOARD

TYP.SECONDFLOORCEILINGCONSTRUCTION

1/2"GYPSUMWALLBOARD 6MIL.POLYVAPOURBARRIER ENGINEEREDROOFTRUSS@24"O/CC/WR-60INSULATION

2x6STUDTOPPLATE 2-2x10WOODLINTELC/WRIGIDINSULATION

MDFWINDOWFRAMEEXTENSION

ALUMINIUMFLASHING

HARDIPANELVERTICALSIDINGBEYOND

PELLAFIBERGLASSSLIDINGWINDOW

MDFWINDOWEXTENSIONBEYOND

INSULATEAROUNDWINDOWFRAME&SEAL VAPOURBARRIERTOWINDOWFRAME MDFWINDOWFRAMEEXTENSION

TYP.SECONDFLOORCONSTRUCTION 1/2"GYPSUMWALLBOARD 2x10FLOORJOISTC/WSOLIDBLOCKING 5/8"T&GPLYWOODSHEATHINGSCREWEDANDGLUED

R-22BATTINSULATIONC/W6 MIL.POLYVAPOURBARRIER

2-2x10WOODLINTELC/WRIGIDINSULATION

2x6STUDTOPPLATE

MDFDOORFRAMEEXTENSION

ALUMINIUMFLASHING

HARDIPANELVERTICALSIDINGBEYOND

MDFDOOREXTENSIONBEYOND PELLAFIBERGLASSSLIDINGWINDOW

TYP.VERTICALSIDINGCONSTRUCTION

HARDIPANELVERTICALSIDINGPANEL 2x4WOODFURRING R-5RIGIDINSULATIONBOARD

HOUSE-WRAP

2x6STUDC/WR-20BATTINSULATION

MILPOLYVAPOURBARRIER

1/2"GYPSUMWALLBOARD

TYP.SECONDFLOORCEILINGCONSTRUCTION 1/2"GYPSUMWALLBOARD 6MIL.POLYVAPOURBARRIER ENGINEEREDROOFTRUSS@24"O/CC/WR-60INSULATION

TYP.DEMISINGWALLSIDINGCONSTRUCTION 5/8"FIRE-RATEDGYPSUMWALLBOARD 6MIL.POLYVAPOURBARRIER 2X6STUDC/WR-24MINERALFIBREINSULATION GYPSUMWALLBOARD HOUSE-WRAP 2x4WOODFURRING HARDIPANELVERTICALSIDINGPANEL

TYP.ROOFCONSTRUCTION ASPHALTSHINGLES ROOFUNDERLAYMENT ROOFSHEATHINGC/WWOODFURRING ENGINEEREDWOODTRUSS@24"O/CC/WR-60INSULATION 5 8T&GPLYWOODSHEATHINGSCREWEDANDGLUED CAULK&SEALBETWEENGYPSUM WALLBOARDANDROOFSHEATHING

TYP.SECONDFLOORCONSTRUCTION 1/2"GYPSUMWALLBOARD 2x10FLOORJOISTC/WSOLIDBLOCKING 5/8"T&GPLYWOODSHEATHINGSCREWEDANDGLUED

DOUBLERIMJOIST

2-2x6TOPPLATE

1"FIRE-RATEDGYPSUMWALLBOARD,NOTTOEXTENDMORE THAN2"BEYONDTOPANDBOTTOMPLATEOFWALLSTUDS LAYERSOFFIRE-RATEDGYPSUMWALL BOARDWHICHWILLACTASFIRE-STOP

TYP.DEMISINGWALL-INTERIORCONSTRUCTION 5/8"FIRE-RATEDGYPSUMWALLBOARD 6MIL.POLYVAPOURBARRIER 2X6STUD@24"O/CMAX.C/WR-24MINERALFIBREINSULATION 1"AIRSPACE 2x4STUD 6MIL.POLYVAPOURBARRIER 5/8"FIRE-RATEDGYPSUMWALLBOARD

INSULATEAROUNDWINDOWFRAMESEAL VAPOURBARRIERTOWINDOWFRAME

STONESILLC/WPOSITIVESLOPE MDFWINDOWFRAMEEXTENSION

TYP.FIRSTFLOORCONSTRUCTION 5/8"T&GPLYWOODSHEATHINGSCREWEDANDGLUED 2x10FLOORJOISTC/WSOLIDBLOCKING

R-22BATTINSULATIONC/W MIL.POLYVAPOURBARRIER 2x4SILLPLATEC/WANCHOR BOLTANDSILLGASKET ALUMINIUMFLASHING WEEPVENT

TYP.FOUNDATIONWALLCONSTRUCTION MIL.POLYVAPOURBARRIER R-20BATTINSULATION HOUSE-WRAP 9"CASTINPLACECONCRETEFOUNDATIONWALL DAMP-PROOFINGLAYER DRAINAGELAYER

TYP.BASEMENTFLOORCONSTRUCTION 4"CASTINPLACECONCRETESLAB MIL.POLYVAPOURBARRIER 4"MIN.COMPACTEDGRANULARFILL

STONESILLC/WPOSITIVESLOPE MDFWINDOWFRAMEEXTENSION

INSULATEAROUNDDOORFRAME&SEAL VAPOURBARRIERTOWINDOWFRAME

TYP.FIRSTFLOORCONSTRUCTION 5/8"T&GPLYWOODSHEATHINGSCREWEDANDGLUED 2x10FLOORJOISTC/WSOLIDBLOCKING

R-22BATTINSULATIONC/W 6MIL.POLYVAPOURBARRIER 2x4SILLPLATEC/WANCHOR BOLTANDSILLGASKET ALUMINIUMFLASHING 2x6STUDTOPPLATE

6"GRANULARLAYER

CASTINPLACECONCRETESTEPS STONEPAVINGSETWITHMORTAR

TYP.FIRSTFLOORCONSTRUCTION 5/8"T&GPLYWOODSHEATHINGSCREWEDANDGLUED 2x10FLOORJOISTC/WSOLIDBLOCKING

SINGLERIMJOIST 2-2x4TOPPLATE

TYP.FIRSTFLOORCONSTRUCTION 5/8"T&GPLYWOODSHEATHINGSCREWEDANDGLUED 2x10FLOORJOISTC/WSOLIDBLOCKING

1/2"EXPANSIONJOINT 9"X18"CASTINPLACECONCRETE FOOTINGC/WCONTINOUSKEYWAY

1/2"EXPANSIONJOINT 9"18"CASTINPLACECONCRETE FOOTINGC/WCONTINOUSKEYWAY

4"ØWEEPINGTILEWITHFILTERFABRIC SOCK,ALSOC/W3/4"CRUSEDSTONE 6"MIN.GRANULARDRAINAGE.

DOUBLERIMJOIST 1"FIRE-RATEDGYPSUMWALLBOARD,NOTTOEXTENDMORE THAN2"BEYONDTOPANDBOTTOMPLATEOFWALLSTUDS LAYERSOFFIRE-RATEDGYPSUMWALL BOARDWHICHWILLACTASFIRE-STOP

2-2x4TOPPLATE

TYPICALDEMISINGWALLSECTION

8"MAX. 8'-9" 10'-0" 8'-0" 9" 8"MIN. 6"MIN. 2'-0" PRE-FINISHED ALUMINIUM VENTEDSOFFIT 1'-8" 6" 8 1/4" 8'-0" 9" 4 1/2" 5'-2 1/4" 3'-7 1/2" 9 3/4" 11 1/4" 4'-3 3/4" 2'-9" SCALE:1/2"=1'-0" TYPICALWALLSECTION
4"ØWEEPINGTILEWITHFILTERFABRIC SOCK,ALSOC/W3/4"CRUSEDSTONE 6"MIN.GRANULARDRAINAGE. CASTINPLACECONCRETESTEPS STONEPAVINGSETWITHMORTAR 4"CASTINPLACE CONCRETESLAB 6"GRANULARLAYER BACKFILL 18"DEEPx2"THICKGRANITE STONESETWITHMORTAR
ASPHALTSHINGLES ROOFUNDERLAYMENT
ALUMINIUMEAVESTROUGH 12 44'-0" TYPES/MROOLEDROOFINGLAPPED &CEMENTED3'MIN.UPROOFSLOPE BUT1'MIN.FROMINSIDEFACEOFWALL ELEV.-8'-9" T/OBASEMENTSLAB-UNIT:B ELEV.+0'-0" T/OFIRSTFLOOR:UNIT-B ELEV.+10'-0" T/OSECONDFLOOR:UNIT-B ELEV.+18'-0" U/SSECONDFLOORCEILING:UNIT-B 10'-0" 8'-0" 7'-0" FRONTPORCHWIDTH 4'-10" CLEARCOLD-ROOMWIDTH 8" MIN. 7'-0"CLEAR HEIGHT SCALE:1/2"=1'-0" TYPICALWALLSECTION-ENTRANCE TYP.BASEMENTFLOORCONSTRUCTION 4"CASTINPLACECONCRETESLAB 6MIL.POLYVAPOURBARRIER 4"MIN.COMPACTEDGRANULARFILL TYP.FOUNDATIONWALLCONSTRUCTION DRAINAGELAYER DAMP-PROOFINGLAYER 9"CASTINPLACECONCRETEFOUNDATIONWALL 6MIL.POLYVAPOURBARRIER
2x10HEADER
ALUMINIUMEAVESTROUGH 8'-9" 2'-0" PRE-FINISHED ALUMINIUM VENTEDSOFFIT 1'-8" 6" 8 1/4" 8'-0" 9" 2'-0" 9 3/4" 11 1/4" 4'-3 3/4" 2'-9" 7'-2 1/4" 12 4 4'-0" &TYPES/MROOLEDROOFINGLAPPED BUT1'CEMENTED3'MIN.UPROOFSLOPE MIN.FROMINSIDEFACEOFWALL BACKFILL 18"DEEPx2"THICKGRANITE STONESETWITHMORTAR ALUMINIUMFLASHING DOOR TYP.ROOFCONSTRUCTION ASPHALTSHINGLES ROOFUNDERLAYMENT ROOFSHEATHINGC/WWOODFURRING ENGINEEREDWOODTRUSS@24"O/C ELEV.-8'-9" T/OBASEMENTSLAB-UNIT:B ELEV.+0'-0" T/OFIRSTFLOOR:UNIT-B ELEV.+10'-0" T/OSECONDFLOOR:UNIT-B ELEV.+18'-0" U/SSECONDFLOORCEILING:UNIT-B ENGINEEREDWOODTRUSS ENGINEEREDWOODTRUSSBEYOND 9" 8"MIN. 8'-9" 10'-0" 8'-0" 8'-9" 9'-0" SCALE:1/2"=1'-0"
TYP.ROOFCONSTRUCTION ASPHALTSHINGLES ROOFUNDERLAYMENT ROOFSHEATHINGC/WWOODFURRING ENGINEEREDWOODTRUSS@24"O/C 4'-0" TYPES/MROOLEDROOFINGLAPPED CEMENTED3'MIN.UPROOFSLOPE BUT1'MIN.FROMINSIDEFACEOFWALL
TYP.BASEMENTFLOORCONSTRUCTION 4"CASTINPLACECONCRETESLAB 6MIL.POLYVAPOURBARRIER 4"MIN.COMPACTEDGRANULARFILL 2'-0" PRE-FINISHED ALUMINIUM VENTEDSOFFIT TYP.BASEMENTFLOORCONSTRUCTION 4"CASTINPLACECONCRETESLAB 6MIL.POLYVAPOURBARRIER 4"MIN.COMPACTEDGRANULARFILL 1/2"EXPANSIONJOINT 9"X18"CASTINPLACECONCRETE FOOTINGC/WCONTINOUSKEYWAY ELEV.-8'-9" T/OBASEMENTSLAB-UNIT:A ELEV.+0'-0" T/OFIRSTFLOOR:UNIT-A ELEV.+9'-0" U/SFIRSTFLOORCEILING:UNIT-A ELEV.-8'-9" T/OBASEMENTSLAB-UNIT:B ELEV.+0'-0" T/OFIRSTFLOOR:UNIT-B ELEV.+10'-0" T/OSECONDFLOOR:UNIT-B ELEV.+18'-0" U/SSECONDFLOORCEILING: UNIT-B BUILDINGTECHNOLOGY FANSHAWE COLLEGE WINDMERE MODERN TOWNHOUSES WALL SECTIONS A-108 PRODUCED BY AN AUTODESK STUDENT VERSION VERSIONSTUDENTAUTODESKANBYPRODUCED PRODUCED BY AN AUTODESK STUDENT VERSION PRODUCEDBYANAUTODESKSTUDENTVERSION

DESIGN PORTFOLIO Sweety Shah