Redevelopment Scheme At Mahim_Muncipal Drawings_2021-22

Page 1

995

47(PT)

AS

L EFF AGE SEW NNEL CHA

TA L

T

995

3

1/2

ENT

47

1575

1

2

5/1

29,94

2/1538

7/1

3/1

3

1/1538

42.67 Meter W id

Dr. Annie Besant Road

LU EFF AGE SEW NNEL CHA

2/1A

1/2

36,11

47(PT) 1575

N

LOCATION PLAN SCALE 1:4000

31,6

1/2

4,61

3,05

2,86

-B/9 999

LOWER PAREL

CARPET AREA STATEMENT CARPET AREA OF FLOOR NO OF FLOORS EACH FLAT GR. FLOOT 0 0 1 ST FLOOR 1,2,3,4 57.63 2 ND FLOOR 5,6,7,8, 57.63 3 RD FLOOR(REFUGE) 9,10 55.71 4 TH FLOOR 11,12,13,14 55.71 5 TH FLOOR 15,16,17,18 55.71 6 TH FLOOR 19,20,21,22 55.71 7 TH FLOOR 23,24,25,26 55.71 8 TH FLOOR 27,28,29,30 55.71 9 TH FLOOR(REFUGE) 30,31,32 58.11 10 TH FLOOR 33,34,35,36 58.11 11 TH FLOOR 37,38,39,40 58.11 12 TH FLOOR 41,42,43,44 58.11 13 TH FLOOR 45,46,47,48 58.11 14 TH FLOOR 49,50,51,52 58.11

54

1/54

54/1

9 -B/9 99 54/1

47(PT) 47(PT)

36,63

1/2

SEWAGE EFFLUENT CHANNEL

1 C/ 54

CO AS TA L

Dr. Annie B

WORLI

54

54/1 -A/9 999

RO AD

3

ENT FLU

EF AGE SEW NEL N CHA

1A/5 4

PLOT U/R

e Dr. Annie B esant Road

esant Roa d

1/3

1C/

1/3 995 1005

N

UEN

1005

47(PT)

54/1 -A/9 999

4

1006

47(PT) 54

ROAD

47(PT)

47(PT)

47(PT)

SEWAGE EFFLUENT CHANNEL

54/1-B/9999 54/1-A/9999

COASTAL ROAD

WORLI

Dr. Annie Besant 3 Road

CHANNEL

1/2

Road

Besant

Annie Road

Besant

Annie

Dr.

47

5/1 1 3/1

1/1538 1575 2/1538

Dr.

COASTAL

1C/54 1/54

2/1A

1A/54

1/2

1575

1/2

47(PT)

2

CHANNEL

7/1

SEWAGE EFFLUENT

LOWER PAREL

SEWAGE EFFLUENT

CO

47(PT) SEWAGE EFFLUENT 47(PT) CHANNEL

LOCATION PLAN

1A/ 54

RO

1006

1/3

AD

4

BUILT UP AREA STATEMENT FLOOR BUILT UP AREA STAIRCASE AREA GR. FLOOT 301.07 45.33 1 ST FLOOR 239.25 45.33 2 ND FLOOR 239.25 45.33 3 RD FLOOR(REFUGE) 147.02 45.33 4 TH FLOOR 303.77 45.33 5 TH FLOOR 303.77 45.33 6 TH FLOOR 303.77 45.33 7 TH FLOOR 303.77 45.33 8 TH FLOOR 303.77 45.33 9 TH FLOOR(REFUGE) 226.02 45.33 10 TH FLOOR 305.02 45.33 11 TH FLOOR 305.02 45.33 12 TH FLOOR 305.02 45.33 13 TH FLOOR 305.02 45.33 14 TH FLOOR 305.02 45.33 TOTAL AREA 4196.56

N

3

EXISTING BLOCK PLAN SCALE = 1:500

Extended Loft for storage

SHOP NO.4 0.900 x 1.350 1.950 x 3.880 3.235 x 4.930 24.749 SM

SHOP NO. 5 3.220 x 10.170 32.748 SM

Extended Loft for storage

SHOP NO. 6 3.220 x 10.170 32.748 SM

Extended Loft for storage

K 250.8 9 ETBAC ROAD S

4.7

9

999

999

-B/9

-A/9

C

1

6.7

54/1

ENTRY FOR RESIDENTS

6.47 7. 84

6.19

4.35

3,095.40 159 19.8 50 4196.56

2

B

6.71

8.29

RG AREA

AOS AREA

SCALE 1:500

SCALE 1:500

60% RG AREA ON EARTH 1.00 2 TOTAL

0.50 0.50

24.40 24.40

X X

AOS AREA

8.29 8.29

X X

101.14 101.14 202.28

1.00 2 TOTAL

0.50 0.50

X X

17.50 17.50

X X

6.70 6.70

58.63 58.63 116.81

40% RG AREA ON PODIUM

1C/ 54

SHOP NO.3 0.900 x 1.350 1.950 x 3.880 3.235 x 4.930 24.749 SM

ENTRY FOR VEHICLES

SHOP NO. 2 3.220 x 10.170 32.748 SM

4.930

SHOP NO. 1 3.220 x 10.170 32.748 SM

3.235

1/2

3.235

7.96

1.65

UP

1.66

1.65

3.220

6.14

10.170

3.220

4.31

STALL AT GROUND FLOOR

UP

2.260

10.170

3.220

10.170

1.381

ST 2.26 x 5.24m 11.84 SQM

10.170

3.890

3.890 10.170

10.170

3.220

SQ.M.

UP

UP

6.07 OHT

9.78

54/1

LOFT ABOVE

11.13

1A/ 54

LOFT ABOVE

42.67 Meter W ide Dr. Annie

LOFT ABOVE

9.77

ENTRY FOR COMMERCIAL

LOFT ABOVE

LOFT ABOVE

STALL AT GROUND FLOOR

1.350

1.350

5.010

LOFT ABOVE

1.950

BALCONY ABOVE

BALCONY ABOVE

1.950

10.1

D

17.5

0.900

A

2

WC 0.9 x 1.2

4.65

AREA IN SQ.M. 301.07 571.29

6.7

19.9

0.900

METER ROOM

WC 0.9 x 1.2

4.14

1.00 2 TOTAL FINAL TOTAL

0.50 0.50

19.92 19.92

X X

6.73 6.71

X X

67.03 66.83 133.86 336.14

N GROUND FLOOR PLAN

PROPOSED BLOCK PLAN

N

SCALE : 1: 100

1.8

SCALE = 1:500

2

33

.2

32

1

0.900

KITCHEN 3.220 x 3.960 12.751 SM

LIVING ROOM 3.220 x 3.960 12.751 SM

2.100

NO.

FLOOR

BUA(SQM) A

EXCESS BALCONY TOTAL BUA AREA(SQM) (SQM) B C=A+B

1

GROUND

206.71

NIL

206.71

49.530 SM 5.944 SM BALC

KITCHEN 3.220 x 3.960 12.751 SM

2

FIRST

206.71

4.84

211.55

3

SECOND

206.71

4.84

211.55

4

TOTAL

620.13

9.68

629.81

1.219

4.876

TOTAL BUA (SQM) C=A+B

11

48.107

1.0815

47.1885

2

12

57.248

1.342

58.59

3

13

57.248

1.342

58.59

4

14

48.107

1.0815

47.1885

TOTAL

206.71

4.847

211.557

N

Flat no. 6 BUA =28.2552 sq.m.

Flat no. 5 BUA =35.8231 sq.m.

Shop no. 4 BUA =30.0613 sq.m.

Shop no. 3 BUA =28.248 sq.m.

Shop no. 2 BUA =35.8231 sq.m.

Shop no. 1 BUA =37.4708 sq.m.

ST 2.26 x 5.24m 11.84 SQM

PERCENTAGE OF ROOM AREAS ON THE FLOOR : 1) Flat nos. 7,10,11,14 = 46.107 x 100 / 206.71= 22.305 % 2) Flat nos. 8,9,12,13 = 57.248 x 100 / 206.71 = 27.694 % EXCESS BALC. DIVIDED INTO ROOMS AS PER PRO RATA : 1) Flat nos. 7,10,11,14 = 4.873 x 22.305 % = 1.086 sq.m. 2) Flat nos. 8,9,12,13 = 4.873 x 27.694 % = 1.349 sq.m. EXISTING BUA INCL. BALC. AREA : a) Flat no. 7,10,11,14 = 46.107 + 1.086 = 47.193 sq.m. b) Flat no. 8,9,12,13 = 57.248 + 1.349 = 58.597 sq.m.

NO.

FLOOR

1

11

48.107

1.0815

47.1885

16.516

63.7045

2

12

57.248

1.342

58.59

20.506

79.096

3

13

57.248

1.342

58.59

20.506

79.096

4

14

48.107

1.0815

47.1885

16.516

63.7045

TOTAL

206.71

4.847

211.557

74.044

285.601

NO.

GROUND FLOOR

SHOP NO.

10

Flat no. 9,13 BUA =57.248 sq.m Exc. balc. area = 1.349 sq.m.

ST 2.26 x 5.24m 11.84 SQM

9

7

NET BUA (SQM) A

35% RESI. FUNG. AREA(SQ.M.) D=35% OF C

TOTAL B.U.A. INCL FUNGIBLE (SQM) E=C+D

PRORETA AREA OF CCOMMON WC (SQM) B

TOTAL BUA (SQM) C=A+B

1

37.471

0.67

38.141

2

35.832

0.64

36.463

3

3

28.247

0.504

28.751

4

4

28.247

0.504

28.751

5

5

35.832

0.64

36.463

6

6

37.471

0.67

38.141

203.082

3.628

206.71

B1 1.33 x 4.34m 5.77 SQM

B1 1.33 x 4.34m 5.77 SQM ST 2.26 x 5.24m 11.84 SQM

GROUND FLOOR A 20.56 x 10.63m 218.55 SQM

NO.

SHOP NO.

NET BUA (SQM) A

SET-BACK AREA

SCALE 1:500

SCALE 1:500

SCALE 1:500

PLOT AREA

PLOT AREA 1.00 2 TOTAL

0.50 0.50

X X

70.34 70.34

X X

33.78 39.85

AREAS OF TOILET DIVIDED INTO SHOPS AS PER PRO RATA : 1) Shop no. 1,6 = 3.62 x 18.127% = 0.656 sq.m. 2) Shop no. 2,5 = 3.62 x 17.33% = 0.627 sq.m. 3) Shop no. 3,4 = 3.62 x 13.665% = 0.494 sq.m.

0.50 0.50

X X

69.18 69.18

TOTAL BUA (SQM) C=A+B

TOTAL B.U.A. INCL FUNGIBLE (SQM) E=C+D

1

1

37.471

0.67

38.141

13.349

51.49

2

2

35.832

0.64

36.463

12.764

49.225

3

3

28.247

0.504

28.751

10.063

38.814 38.814

4

4

28.247

0.504

28.751

10.063

5

5

35.832

0.64

36.463

12.764

49.225

6

6

37.471

0.67

38.141

13.349

51.49

203.082

3.628

206.71

72.348

279.056

72.85 72

34.70 32.79

X X

1200.28 1134.21 2334.49

1.0000 2 TOTAL

0.50 0.50

X X

61.44 60.66

WATERPROOFING

X X

6.39 1.80

DOMESTIC WATER

FLUSHING WATER

5 6 7

STAIRCASE MUMPTY

SECTION OF O.H.T Scale - 1:20

VENT PIPE

GROUND LEVEL

0.884

VENT PIPE

0.884

0.884

0.50M THK RUBBLE MASONRY WALL

0.442

0.1M THK P.C.C.

DOMESTIC

FLUSHING 0.295 0.442

P.C.C

RAFT

RUBBLE SOILING

0.442

0.589

0.589

8.9895

C.I. LADDER

CONSOLIDATED EARTH

SECTION OF COMPOUND WALL

0.442

SUMP

C.I. LADDER

TYPICAL FLOOR(FIRST AND SECOND FLOOR)

0.295

SECTION OF U.G.T Scale - 1:20

DESCRIPTION FOR UGT TYPE OF TENAMENTNO.OF PEOPLE(NBC) NO.OF FLATS/FLOOR 2BHK 6 4 OCCUPANTS/FLOOR NO. OF FLOORS TOTAL OCCUPANTS

WATER REQUIRED FOR 1 PERSON PER DAY (90(D)+45(F)) TOTAL WATER REQUIRED FOR ENTIRE BUILDING TOTAL CAPACITY OF WATER REQUIRED FOR ENTIRE BUILDING

8 9 10 11

CONSIDERING HEIGHT OF UGT [2.2+0.3(FREEBOARD)] AREA OF TANK THE LENGTH AN BREADTH DIMENSION OF UGT (l x b xh) FOR UGT

1 2 3 4 5

CAPACITY OF OHT IS 1/2 OF UGT CONSIDERING HEIGHT OF UGT (2.2+0.3(FREEBOARD)) AREA OF TANK THE LENGTH AN BREADTH DIMENSION OF OHT (l x b xh)

0.884

0.3 FREE BOARD

0.295

0

0 0

0 0 251.57 2,345.18 2,345.18 1.33 3119.0894 3119.0894 0 0 0 0 0 3119.0894 3119.0894 251.57 1091.68129 220.46 220.46 871.22129 871.22129 4210.77069 4210.77069 1.33 NA NA NA NA NA 117.26

351.777 180 4210.77069 279.05 3931.72069 180 45

53 13 6 0 0 0 72 0 0 0

BLOCK PLAN, LOCATION PLAN, RG & AOS AREA,PLOT AREA, EXISTING BUILDING BUA, BUA CALCULATION, UGT & OHT CALCULATION

196.30 54.59 250.89

1 2 3 4

0.3 M FREE BOARD OVERHEAD WATER TANK

0 251.57 0

CONTENT OF SHEET CONTENT OF SHEET

BUND WALL TO COLLECT WATER

EXISITING BUA INCL. TOILET : 1) Shop no. 1,6 = 37.4708 + 0.656 = 38.126 sq.m. 2) Shop no. 2,5 = 35.8231 + 0.626 = 36.45 sq.m. 3) Shop no. 3,4 = 28.248 + 0.494 = 28.742 sq.m.

35% COMM. FUNG. AREA(SQ.M.) D=35% OF C

0.6 66.25 6.6

SETBACK AREA

R.C.C SLAB

PRORETA AREA OF CCOMMON WC (SQM) B

53 13.25 66.25 6

Built Up Area due to "Admissible TDR" as per Table 12 of Reg. No. 11 30(A) & 32 12 Permissible Built Up Area (With/Without 2( C) 13 Proposed BUA (With/Without 2 ( C) 14 TDR generated if any as per Reg. no. 30(A) & 32 15 Fungible Compensatory Area as per Reg. No. 31(3) i) Permissible Fungible Compensatory area for 15 a) Rehab Component without charging premium ii) Fungible Compensatory area availed for rehab component without charging premium i) Permissible Fungible Compensatory area by charging premium 15 b) ii) Fungible Compensatory area availed by charging premium Total Built Up Area Permissible including Fungible Compensatory 16a) Area (13 + 15 (a)(ii) + 15(b)(ii)) Total Built Up Area Proposed including Fungible Compensatory 16b) Area 17 FSI consumed on net plot (13/4) II. OTHER REQUIREMENTS (A) Reservation / Designation a) Name of Reservation b) Area of Reservation affecting the plot c) Area of Reservation land to be handed over as per Reg. No. 17 d) Built up Area of Amenity to be handed over as per Reg. No. 17 (B) Plot Area/ Built up Amenity to be handed over as per i) Regulation No. 14 (A) of DCPR 2034 ii) Regulation No. 14 (B) of DCPR 2034 iii) Regulation No. 15 of DCPR 2034 Requirement of Recreational Open space in layout / plot as (C) per Reg. No. 27 (D) Tenement Density (i) Proposed Built up area (13 above) (ii) Less Non-Residential Area (shop etc.) (iii) Area available for Tenements (i - ii) (iv) Tenements permissible (450/ Hec) (V) Tenements proposed on the plot (E) Parking Statement ( I) Parking Required by Regulations for: Car, Scooter/Motor Cycle Outsiders (Visitors) (ii) Covered garage permissible (iii) Covered garage proposed Proposed Car, Scooter / Motor Cycle Outsiders (Visitors) (iv) Total Parking Provided (F) Transport Vehicles Parking (i) Space for transport vehicles parking required by Regulation (ii) Total No. of Transport vehicles parking spaces Provided

IN SQ.MT AS PER DCPR 2034 2596.75 251.57 251.57 0

PRO FORMA-B

SR NO.

EXISTING TOILET AREA : a) Toilet 1 x 2 = 1.810 x 2 = 3.620 sq.m. PERCENTAGE OF SHOP AREAS ON GROUND FLOOR : 1) Shop 1,6 = 37.4708 x 100 / 206.710 = 18.127% 18.1268 2) Shop 2,5 = 35.8231 x 100 / 206.710 = 17.33% 3) Shop 3,4 = 28.248 x 100 / 206.710 = 13.665%

1.00 2 TOTAL

1188.04 1401.52 2589.56

AREA STATEMENT

1 Area of Plot a)Area of Reservation in plot b)Area of Road Set back c)Area of D.P. Road 2 Deduction for: 2A For Reservation/Road Area a) Road Set back area to be handed over (100%) (Reg.No. 16) b) Proposed D.P.Road to be handed over(100%) (Reg.No.16) c) i) Reservation area to be handed over (100%) (Reg.No. 17) ii) Reservation area to be handed over as per Accommodation Reservation (Reg.No. 16) 2B For Amenity Area a)Area of Amenity plot to be handed over as per Reg.No.14(A) b)Area of Amenity plot to be handed over as per Reg.No14(B) c) Area of Amenity plot to handed over as per Reg.No.35 (Abeyance) Deduction for Existing BUA to be retained / Land Component of Existing BUA /Existing BUA as per Regulation under which the 2C development was allowed. 2D Deduction for area under encroachment 3 Total Deductions[(2(A)+2(B)+2(C))as and when applicable.] 4 Balance area of plot (1-3) Plot area under development after areas to be handed over to MCGM/Appropriate Authority as per Sr.No. 5 4above. 6 Zonal FSI (1.33) due to CRZ III

WATER REQUIREMENTS(RESIDENTIAL)

0.23M THK RUBBLE SOLING B2 10.20 x 1.37m 13.97 SQM

61.44

NET PLOT AREA

BUA = 206.710 sq.m. EXISTING SHOP AREAS : a) Shop. 1,6 = 37.4708 sq.m. b) Shop no. 2,5 = 35.8231 sq.m. c) Shop no. 3,4 = 28.248 sq.m.

2

TOTAL

TYPICAL FLOOR(FIRST AND SECOND FLOOR)

60.66

PLOT AREA

TOTAL REHAB B.U.A. OF EACH SHOP ON G FLOORS INCLUDING FUNGIBLE AREA

8

Flat no. 8,12 BUA =57.248 sq.m Exc. balc. area = 1.350 sq.m.

TOTAL BUA (SQM) C=A+B

1

TOTAL

Flat no. 7,11 BUA =46.107 sq.m Exc. balc. area = 1.087 sq.m.

NET BUA(SQM) EXCESS BALCONY A AREA(SQM) B

BUA OF EACH SHOP ON G FLOORS GROUND FLOOR A 20.56 x 10.63m 218.55 SQM

GROUND FLOOR

Flat no. 10,14 BUA =46.107 sq.m Exc. balc. area = 1.086 sq.m.

6.39

REHAB RES. BUA WORKS TO : a) Flat no. 7,10,11,14 = 47.193+(47.194 x 35%) = 63.712 sq.m. b) Flat no. 8,9,12,13 = 58.597+(58.59 x 35%) = 79.10 sq.m.

WC 0.9 x 1.2

ST 2.26 x 5.24m 11.84 SQM

7

BUA = 206.71 sq.m. Perm. Balc. = 10% of 206.71 = 20.671 sq.m. Existing Balc. = 5.789+5.789+6.983+6.983 = 25.544 sq.m. Excess Balc. = 25.544 - 20.671 = 4.873 sq.m.

TOTAL REHAB B.U.A. OF FLATS ON 1ST EXISTING FLOORS

WC 0.9 x 1.2

70 .5

FREE OF FSI AREA STAIRCASE =2.26 x 5.24m=11.84 SQM

1) 2) 3) 4) EXCESS BALCONY AREA(SQM) B

1

2

2.100

TYPICAL FLOOR PLAN ( 1ST & 2ND FLOOR ) SCALE : 1: 100

4.876

1

NET BUA(SQM) A

.2

0.442

1.219

BALCONY 4.876 x 1.219 5.944 SM

FLOOR

34

NET BUILTUP AREA OF GROUND FLOOR 218.55- 11.84= 206.71

BUA OF FLATS ON 1ST EXISTING FLOORS NO.

39 .2 8

0.589

49.530 SM 5.944 SM BALC

BEDROOM 3.220 x 3.960 12.751 SM

3.220

0.442

LIVING ROOM 3.235 x 5.010 16.207 SM

DEDUCTION a=2.26 x 5.24M TOTAL AREA= 11.84 SQM

0.442

3.220

A

1.800

3.235

2

2.400

LIVING ROOM 3.235 x 5.010 16.207 SM

5.010

BEDROOM 3.220 x 3.960 12.751 SM

3.235

3.960

KITCHEN 3.220 x 3.960 12.751 SM

1.200

12

3.960

3.220

AREA STATEMENT OF EXISTING FLOORS

1.500

5.390

13 3.220

W.C 1.200 x 0.900 1.080 SM

PASSAGE 5.390 x 0.900 4.851 SM

5.390

5.010

1.200

0.900

0.900

PASSAGE 5.390 x 0.900 4.851 SM

0.900

W.C 1.200 x 0.900 1.080 SM

AREA STATEMENT GROUND FLOOR A A=20.56 x 10.63M TOTAL AREA= 218.55 SQM

0.300

BATH 2.100 x 0.900 1.890 SM

2.260

1.800

11

0.900

4.490

0.900

14

2.160

DN

3.960

BATH 2.100 x 0.900 1.890 SM

UP

PASSAGE 4.490 x 0.900 1.950 x 2.160 0.900 x 1.500 9.603 SM

0.900

0.900

4.490

1.950

PASSAGE 4.490 x 0.900 1.950 x 2.160 0.900 x 1.500 9.603 SM

1.381

2.160 2.100

3.960

71 .6 5

4.827 SM BALC 1.950

0.900

BALCONY 1.219 x 3.960 4.827 SM

38.615 SM

4.827 SM BALC

BALCONY 1.219 x 3.960 4.827 SM

SAME AS FOR Reqd. Parking Total Carpet Area REG. 33/10 No. of flats Upto 45 SQ.MT 1 per 4 units 0 45 to 60 sq.mt 1 per 2 units 53 26.5 60 to 90 sq.mt 1 per 1 unit 0 Above 90 sq. mt 2 per 1 unit Total CONSIDERING 1 PER1 UNIT 53 Parking for visitor(25%) 13.25 TOTAL X 25/100 TOTAL FOR RESIDENTIAL USER ( R) TOTAL Non Residential (NR) 1 per 40sq.m. 6 6 Visitor Parking For Non Residential (10%) Minimum-2 Total parking reqd, for R user Total parking reqd, for NR user parking reqd. Total parking reqd. Total parking provided

1

1.219

3.960

3.960

2.700

1.500

3.220

B

BATH 0.900 x 2.700 2.430 SM

0.900

5.010

3.220

3.960

1.200

W.C 0.900 x 1.200 1.080 SM

0.900

38.615 SM

10.630

0.900 1.100

W.C 0.900 x 1.200 1.080 SM

1.500

KITCHEN 3.220 x 3.960 12.751 SM

2.260

0.900

BATH 0.900 x 2.700 2.430 SM 3.960

LIVING ROOM 3.220 x 3.960 12.751 SM

0.900

1.200

3.220

2.700

3.220

3.960

3.960

1.219

PARKING STATEMENT Residential user

.2 4

20.560

SR. NO.

7 Built up area as per Zonal (basic) FSI (5 x 6) 8 Built up equal to area of land handed over as per Reg.No.30(A) i) As per 2(A) & 2(B) except 2(A)(c)(ii) above with in cap of Admissible TDR ii)In case of 2(A)(c)(ii) permissible over and above permissible BUA Built Up Area in lieu of cost of Construction of built up amenity to 9 be handed over (With in limit of permissible BUA) Built Up Area due to "Additional FSI on payment 10 of premium" as per Table 12 of Reg. No. 30(A)

6.73

8.29

24.4

3

20.560

8.57

UGT

SCALE 1:4000

AOS 116.81 SQ.M.

RG 202.25 SQ.M.

N

LOCATION PLAN

Besant Road

1/3

995

SPACE SHOPS REHAB RESIDENTIAL FLAT SALES RESIDENTIAL FLAT REFUGE AREA SOCIETY OFFICE YOGALAY TOTAL

PROFORMA A

UNITS

STAMP OF DATA OF STAMP OF APPROVAL RECEIPT OF PLAN OF PLAN

TOTAL NO.OF PEOPLE 24 24 12 288 PEOPLE 135 LITRES 38880 LITRES 124.2 CUBIC M 2.5 M 49.68 sq.m 7M 5x3.9 x 2.5 62.1 CUBIC M 2.5 M 24.84 sq.m 5m 3x3.31 x 2.5

DESCRIPTION OF PROPOSAL REDEVELOPMENT PROJECT FOR AN EXISTING RESIDENTIAL BUILDING OF CTS NO. 03 OF G/S WARD OF WORLI, MUMBAI 400018.

JOB NO. DRG. NO.

1

DATE

DRN. BY

CHK. BY

REVISION

1/7 21/10/21

NAME AND SIGNATURE OF ARCHITECT

PRATHAMESH NIMBALKAR ROLL NO. 1818 MUNICIPAL DRAWINGS (ARD-SEM07) ACADEMY OF ARCHITECTURE


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.