HIAWATHACOMMUNITYCENTER STABILIZATION
ParksSpecification#2067PW#2021-016Project#PRK730301-20
ProjectSite Location
CITYOFSEATTLE-NOTTOSCALE
LOCATIONMAP
SeattleWaterDepartment SWD
Administration Adjustable,Adjoining,Adjacent AboveFinishFloor AFF AcousticCeilingTile ACT ADMIN ADJ AverageBuildingElevation ABE AboveFinishedGrade AFG AutomaticSprinklerRiser Alternate Anodized ANOD ASR ALT Aluminum ALUM Building BLDG BottomofFinishFloor BFF Board BD Between BTW ControlJoint CJ CeramicTile CT Carpet CPT Contractor Contr ConstructionConstr Column COL ConcreteMasonryUnit CMU Drawing DWG Downspout DS Dimension DIM DrinkingFountain DF Depth/Deep D Floordrain FD FireExtinguisherCabinet FEC FireExtinguisher FE Foundation FDN FCIC FurnishbyOwner,InstallbyContractor FOIC FloorFinish/FactoryFinish FF FurnishbyContractor,InstallbyContractor FOIO FurnishbyOwner,InstallbyOwner FRP FrostProofHoseBib FPHB FrostProofDrinkingFountain FPDF FiberReinforcedPanel FTG Footing GP GypsumLathandPlaster GeneralContractor GC GypsumBoard GB Gauge GA GLP GypsumWallBoard GWB HotWaterTank HWT Height HT HollowMetal HM Insulated INS Level LVL Laminate LAM MetalBuildingSupplier MBS Masonry MAS Mount MT MasonryOpening MO Manufacturer MFR Manufacturing MFG Mezzanine Mezz MechanicalMECH MarmoleumCompositeTile MCT Metal MTl MoistureResistant MR Nominal NOM Over O/ Overhead OH Opposite OPP Panel Painted PT Project PROJ PNL Plumbing Plumb PlasticLaminateP-LAM Perpendicular PERP QuarryTile QT RightofWay ROW RoughOpening RO RainLeader RL RubberFlooring RF Received Rec'd Similar SIM SiteVerify SV System SYS Suspended SUSP Standard STD StainlessSteel,SideSewer SS Sheet SHT SafetyGlass SG SquareFoot SF SCHEDSchedule SolidCore SC Tempered,Tread,Top T UnlessNotedOtherwise UNO TopOf TO TongueandGroove TG Tempered Temp TopandBottom TB Utility UTIL MechanicalJoint MJ Maximum Max ManualDrainValve MDV ManualControlValve MCV R PI WeldedWireMesh WWM YardDrain TD WeldedWireFabric WWF Weight WT WaterResistant WR Waterproof WP WalkOffMatW/MAT Without W/O With W/
PROPERTYNAME HIAWATHACOMMUNITYCENTER
SHEETINDEX
G-001 COVERPAGE
G-002 GENERALNOTES
G-003 CODEDATASHEET
CIVIL
C-100 GENERALNOTES
C-101 DEMO&TESCPLAN
C-102 TESCDETAILS
C-103 GRADING&PAVINGPLAN

LEGALDESCRIPTION
"PARCELB"SEATTLELOTBOUNDARYADJUSTNO2401073RECNO 20050316900014BEINGAPOROFSW1/4OFSE1/4STR11-24-03
KINGCOUNTYPARCELNUMBER ParcelNo.:1124039001
PROJECTSCOPE:
INTERIORIMPROVEMENTSTOEXISTINGCOMMUNITYCENTERINTERIOR FINISHES,INCLUDINGACCESSIBILITYIMPROVEMENTS. EXTERIORIMPROVEMENTSINCLUDERE-GRADINGEXISTINGWALKWAYS ANDRAMPSTOMEETADAREQUIREMENTS,REPAIRSTOTHEEXTERIOR, ROOFREPLACEMENTANDELECTRICALUPGRADES.
BIDADDITIVE01-ELECTRICWORKTHATINCLUDESSWITCHGEARS& CHANGINGELECTRICALPANELS.
BIDADDITIVE02-ROOFREPLACEMENT,ROOFTOPUNIT&LOWSLOPE ROOFINSULATION.
BUILDINGCODEINFORMATION
APPLICABLECODES
BUILDINGCODE: 2015SEATTLEBUILDINGCODE (2015IBCWITHCITYOFSEATTLE AMENDMENTS)
FIRECODE: 2015SEATTLEFIRECODE
ENERGYCODE: 2015SEATTLEENERGYCODE (2015WSECWITHCITYOFSEATTLE AMENDMENTS)
MECHANICALCODE: 2015SEATTLEMECHANICALCODE
PLUMBINGCODE: 2015SEATTLEPLUMBINGCODE (2015WSPCWITHCITYOFSEATTLE AMENDMENTS)
ZONINGINFORMATION
ZONING: SF5000
EXISTINGUSE: GOVERNMENTALCOMMUNITYSERVICEBLDG
LOTSIZE: 526,297SF
BUILDINGCONSTRUCTIONINFORMATION
BUILDINGYEAR: 1915
OCCUPANCYCLASS: ASSEMBLYA3
CONSTRUCTIONTYPE:VB
STORIES: 2WITHPARTBASEMENT
BASEMENTAREA: 1416.0SF
FIRSTFLOORAREA: 11212.5SF
SECONDFLOORAREA: 4749.0SF
SPRINKLERSYSTEM: YES
BUILDINGNETSF: 17513.5SF
FundingSource:SeattleParksDistrict AdministeringDepartment: CityofSeattleDepartmentofParksandRecreation,Planning&DevelopmentDivision 300ElliottAvenueWest,Suite100,Seattle,WA98119

C-104 GRADINGANDPAVINGDETAILS
C-105 OSMEXHIBITWITHCALCULATIONSHEET
STRUCTURAL
S-001 GENERALNOTESANDSPECIALINSPECTIONS
S-101 FLOORPLAN
S-102 SECONDFLOORPLAN
S-103 ROOFPLAN
S-201,2 ELEVATIONS
S-301,2 SECTIONS&DETAILS
S-501,2 SECTIONS&DETAILS
ARCHITECTURALDEMOLITION
AD101 FIRSTLEVELDEMOPLAN
AD102 SECONDLEVELDEMOPLAN
AD103 ROOFDEMOPLAN
AD104 EXTERIORELEVATIONDEMO
ARCHITECTURAL
A-101 SITEPLAN
A-101.1 STAGINGAREA
A-102 FIRSTFLOORPLAN
A-103 SECONDFLOORPLAN
A-104 ROOFPLAN
A-111 FIRSTFLOORREFLECTEDCEILINGPLAN
A-112 SECONDFLOORREFLECTEDCEILINGPLAN
A-201,2 EXTERIORELEVATION
A-401,2 ENLARGEDPLAN
A-403,4,5INTERIORELEVATIONSLOBBY,RR's&KITCHEN
A-406,7,8INTERIORELEVATIONSGYMNASIUM
A-409 INTERIORELEVATIONAUDITORIUM
A-501 TYPICALADADETAILS
A-502 DETAILS
A-503 DETAILS
A-504,5,6DETAILS
A-507,8,9DETAILS
A-510 WALL&ROOFTYPES
A-601 DOORSCHEDULE
A-602 WINDOW&FINISHSCHEDULES
MECHANICAL
M-001 MECHNOTESANDLEGEND
M-002,3 MECHANICALSCHEDULES
M-100 BASEMENTMECHDEMOPLAN
M-101 LEVEL1MECHDEMOPLAN
Owner: CityofSeattleDepartmentofFinance&AdministrativeServices, Purchasing&ContractingServicesDivision
ProjectManager:KellyGoold206386-1959
ProjectDesignTeam: RolludaArchitectsINC
105SouthMainStreet,Suite323,Seattle,WA98104
PrimaryContact:RichMurakami,richard@rolludaarchitects.com
ED101 DEMO-BASEMENTPOWERPLAN
ED102 DEMO-FIRSTFLOORPOWERANDSYSTEMSPLAN
ED103 DEMO-FIRSTFLOORLIGHTINGPLAN
ED104 DEMO-SECONDFLRPOWERANDSYSTEMSPLAN
ED105 DEMO-SECONDFLOORLIGHTINGPLAN
ED201 DEMO-ONE-LINEDIAGRAM
E-101 BASEMENTPOWERPLAN
E-102 FIRSTFLOORPOWERANDSYSTEMSPLAN
E-103 FIRSTFLOORLIGHTINGPLAN
E-104 SECONDFLRPOWERANDSYSTEMSPLAN
E-105 SECONDFLOORLIGHTINGPLAN
E-201 ONE-LINEDIAGRAM
E-301 NRECFORMS
E-302, ELECTRICALSCHEDULES
E-303,4,5PANELSCHEDULES
FOODSERVICE
FS100 FLOORPLAN&SCHEDULE
FS102 ELEVATIONS&DETAILS
FS103 VENTILATORDETAILS
PROJECTCONSULTANTS
ARCHITECT:
ROLLUDAARCHITECTS
PRIMARYCONTACT:
RICHMURAKAMI206624-4222
STRUCTURAL:PSMCONSULTINGENGINEERSINC.
PRIMARYCONTACT: RONMARTINSON206239-7706
CIVIL: KPFF
PRIMARYCONTACT:
ALBERTOCISNEROS206926-0519
MECHANICAL: GREENBUSCHGROUP
PRIMARYCONTACT: RICKFREDERICKSON206378-0569*114
BLDGENVELOPE:WETHERHOLTANDASSOCIATES
PRIMARYCONTACT:
DONDAVIS425822-8397
KITCHEN: JLRDESIGNGROUP
ELECTRICAL: SAZANGROUP
PRIMARYCONTACT:
ELMOACACIO206576-7195
HAZMAT: PBSENVIRONMENTAL PRIMARYCONTACT:
COST:
TIMOGDEN206766-7611
JBIRINGAN
PRIMARYCONTACT:
6250 REGISTERED ARCHITECT AlexE.Rolluda STATEOFWASHINGTON
HIAWATHACOMMUNITYCENTER
STABILIZATION
COVERSHEET
WWW.CALL811.COM
Restroom RR Also,verifyallundergroundutilitiesnotlocatedbythe 811servicebyusingacommerciallocationserviceand callSPRInspectionRequestLine(206)684-7034. >>>>CAUTION-CALL811<<<< UTILITYNOTIFICATIONCENTER BEFOREYOUDIG!
1 92 G-001
1.ALLWORKSHALLCONFORMTOTHE2020CITYOF SEATTLESTANDARDSPECIFICATIONSFORROAD, BRIDGE,ANDMUNICIPALCONSTRUCTION;THECITYOF SEATTLESTANDARDPLANS,2017EDITION;AND SEATTLETRANSPORTATION(SDOT),DIRECTOR'SRULE 05-2009FORSTREETANDSIDEWALKPAVEMENT OPENINGANDRESTORATION.ACOPYOFTHESE DOCUMENTSSHALLBEONSITEDURING CONSTRUCTION.
2.ACOPYOFTHEAPPROVEDPLANMUSTBEONSITE WHENEVERCONSTRUCTIONISINPROGRESS.
3.THECONTRACTORSHALLOBTAINALLPERMITS REQUIREDFORWORKWITHINTHEPUBLICRIGHTOF WAY.
4.PRIORTOANYCONSTRUCTIONACTIVITY,THE CONTRACTORSHALLSCHEDULEANDATTENDA PRE-CONSTRUCTIONCONFERENCEWITHTHEPARK ENGINEER.THECONTRACTORSHALLNOTIFYTHE OWNER'SPROFESSIONALENGINEERINGCONSULTANT OFTHEPRE-CONSTRUCTIONMEETINGTIMEAND LOCATION.

5.PAVEDSURFACESINCLUDINGROADWAYS,SIDEWALKS, ANDCURBSTHATAREDAMAGEDBYCONSTRUCTION SHALLBEREPAIREDASREQUIREDBYTHESDOT STREETUSEINSPECTORORPARKENGINEER.
6.DATUM:HORIZONTAL:WANZNAD83/91,VERTICAL: NAVD-88ASESTABLISHEDBYTHESITESURVEY. TOPOGRAPHICSURVEYISBYDEPTOFPARKSLAND SURVEYORS.
7.ALLSURVEYINGANDSTAKINGOFIMPROVEMENTSIN THEPUBLICRIGHTOFWAYISTOBEPROVIDEDBYTHE CITYOFSEATTLEATOWNER'SEXPENSE.
8.THECONTRACTORSHALLNOTIFYTHESEATTLEFIRE DEPARTMENTDISPATCHER(386-1495)TWENTY-FOUR (24)HOURSINADVANCEOFALLWATERSERVICE INTERRUPTIONS,HYDRANTSHUTOFFS,ANDSTREET CLOSURESOROTHERACCESSBLOCKAGE.THE CONTRACTORSHALLALSONOTIFYTHEDISPATCHEROF ALLNEW,LOCATED,ORELIMINATEDHYDRANTS RESULTINGFROMTHISWORK.
9.ALLLOCATIONSOFEXISTINGUTILITIESSHOWNHEREON HAVEBEENESTABLISHEDBYFIELDSURVEYOR OBTAINEDFROMAVAILABLERECORDSANDSHOULD THEREFOREBECONSIDEREDAPPROXIMATEONLYAND NOTNECESSARILYCOMPLETE.ITISTHESOLE RESPONSIBILITYOFTHECONTRACTORTO INDEPENDENTLYVERIFYTHEACCURACYOFALL UTILITYLOCATIONSSHOWNANDTOFURTHER DISCOVERANDAVOIDANYOTHERUTILITIESNOT SHOWNHEREONWHICHMAYBEAFFECTEDBYTHE IMPLEMENTATIONOFTHISPLAN.
10.THECONTRACTORSHALLLOCATEANDPROTECTALL CASTINGSANDUTILITIESDURINGCONSTRUCTIONAND SHALLCONTACTTHEUNDERGROUNDUTILITIES LOCATORSERVICE(1-800-424-5555)ATLEAST48HOURS PRIORTOCONSTRUCTION.
11.THECONTRACTORSHALLADJUSTALLEXISTING MANHOLERIMS,DRAINAGESTRUCTURELIDS,VALVE BOXES,ANDUTILITYACCESSSTRUCTURESTOFINISH GRADEWITHINAREASAFFECTEDBYTHEPROPOSED IMPROVEMENTS.
12.UTILITYSERVICECONNECTIONSSHOWNONTHISPLAN ARETOBEMAINTAINEDBYTHEDEPARTMENTOF PARKS.
13.THECONTRACTORSHALLPROVIDEFORALL COMPACTIONTESTSREQUIREDBYTHESTREETUSE INSPECTORORPARKSENGINEER.
14.BACKFILLMATERIALUSEDINPUBLICRIGHT-OF-WAY SHALLMEETSTDSPECS.ANDSHALLBEAPPROVEDBY SDOTORPARKSENGINEER.
15.INSPECTIONANDACCEPTANCEOFALLWORKIN STREETRIGHTS-OF-WAYWILLBEACCOMPLISHEDBY REPRESENTATIVESOFTHECITYOFSEATTLE.ITSHALL BETHECONTRACTOR'SRESPONSIBILITYTO COORDINATEANDSCHEDULEAPPROPRIATE INSPECTIONS,ALLOWINGPROPERADVANCENOTICE. THEINSPECTORMAYREQUIRERECONSTRUCTIONOF ITEMSTHATDONOTMEETCITYSTANDARDSORTHAT WERECONSTRUCTEDWITHOUTINSPECTION.
16.ALLTRAFFICCONTROLSHALLBEINACCORDANCEWITH THETRAFFICCONTROLMANUAL.ATRAFFICCONTROL PLANWILLBEREQUIREDPRIORTOISSUANCEOF PERMIT.
17.ALLWORKPERFORMEDBYSEATTLECITYLIGHT, SEATTLEWATER,ANDOTHERPUBLICUTILITIESTO REMOVEORRELOCATEEXISTINGUTILITIESSHALLBE DONEATTHEPERMITTEE'SEXPENSE.
18.CARESHALLBEEXERCISEDWHENEXCAVATINGNEAR EXISTINGCHARGEDWATERMAINS.
19.CONTRACTORSHALLNOTIFYKINGCOUNTYTRANSITAT (206)684-2732SEVENDAYSINADVANCEOFANYIMPACT TOTRANSITOPERATIONS.
20.ALLDIMENSIONSPROVIDEDAREFROMANDTOFACE OFSTUD,EXCEPTDIMENSIONSFROMEXISTINGWALLS ANDSTRUCTURESWHICHAREFROMFACEOFFINISH.
21.CLASS2AFIREEXTINGUISHERSTOBEPROVIDEDAT EVERYCONSTRUCTIONSTORAGE,OFFICESHEDOR STORAGEROOM,STAIRWAYSINFLOORSWHERE COMBUSTIBLEMATERIALISSTORED,WORKSHOPS, TEMPORARYANDWITHIN30'OFHOTWORK.
22.CONTRACTORMATERIALANDACTIVITIESSHALLNOT BLOCKEGRESSFROMANYBUILDINGWHILEOCCUPIED.
23.FIRESAFETYISTOBEPROVIDEDDURING CONSTRUCTIONWORKINACCORDANCEWITHSFC33 THATINCLUDESTEMPORARYHEATINGEQUIPMENT, PRECAUTIONSAGAINSTFIRE,FLAMMABLEAND COMBUSTIBLELIQUIDS,FLAMMABLEGASES,EXPLOSIVE MATERIALS.
UNLESSOTHERWISESPECIFIED:
1.PIPELESSTHAN12"DIAMETERSHALLBEPVCORPER CITYOFSEATTLESTANDARDS.
2.DUCTILEIRONPIPESHALLBEPERANSIA21.51CLASS50 WITHPUSH-ONJOINTS.FITTINGSFORDUCTILEIRONPIPE SHALLBEDUCTILEPERANSIA21.10ORANSIA21.53WITH PUSH-ONJOINTS.GLANDSONMECHANICALJOINTPIPE ANDFITTINGSSHALLBEDUCTILE.\
3.PVCPIPEANDFITTINGSSHALLBEPERASTMD3034, SDR35WITHRUBBERGASKETJOINTS.PVCPIPEFORPSS ANDPSDSHALLBETESTEDFOREXCESSIVEDEFLECTION WITHAMANDRELPERSECTION7-17.3(4)OFTHE SPECIFICATIONS.
4.SUBSURFACEDRAIN(SSD)PIPEANDFITTINGSSHALLBE PVCPERASTMD2241SDR21(CLASS200)WITHRUBBER GASKETJOINTS.PIPESHALLHAVESLOTTED PERFORATIONS.SLOTSARETOBE0.040"WIDE1.0"LONG ANDSPACED0.25"APART.SLOTLOCATIONSSHALLBE LOCATEDPERDETAILONPLAN.
5.BEDDINGSHALLBECLASSBFORALLPIPEEXCEPT DUCTILEIRONPIPE,WHICHSHALLBECLASSD.BEDDING MATERIALFORPVCPIPEANDCMPSHALLBEMINERAL AGGREGATETYPE22.BEDDINGMATERIALFORPVCPIPE ANDCMPSHALLBEMECHANICALLYCOMPACTEDTO95% OFMAXIMUMDRYDENSITYASMEASUREDBYASTMD-698.
6.TEESONNEWPIPELESSTHAN24"DIAMETERSHALLBE PREFABRICATED.TEESONEXISTINGPIPEORONNEW PIPEWITHOUTPREFABRICATEDTEESSHALLBE CONNECTEDBYCOREDRILLINGANDFLEXIBLE CONNECTION.SEESPECIFICATIONS.
7.TEES,CATCHBASINCONNECTIONS,SIDESEWERS,AND SERVICEDRAINSSHALLBEPLACEDATAMINIMUMSLOPE OF2%ANDAMAXIMUMSLOPEOF50%.INLET CONNECTIONSSHALLBEPLACEDATAMINIMUMSLOPE OF5%ANDAMAXIMUMSLOPEOF50%.
8.RECONNECTIONOFEXISTINGCATCHBASINSSHALL INCLUDENEWTRAPS,CONNECTIONTOSTORMDRAINS, ANDREMOVALOFEXISTINGTRAPS.
9.SERVICEDRAINSANDSIDESEWERSSHALLBE CONNECTEDORRECONNECTEDASAPPROVEDBYTHE INSPECTORORPARKSENGINEER.
10.RELAYEXISTINGSERVICEDRAINSANDSIDESEWERSTO CLEAROVERORUNDERTHENEWUTILITYASAPPROVED BYTHEPARKSENGINEER.
11.WHEREANEWPIPECLEARSANEXISTINGORNEW UTILITYBY6"ORLESS,POLYETHYLENEPLASTICFOAM SHALLBEPLACEDASACUSHIONBETWEENTHE UTILITIES.
12.SERVICEDRAINSANDSIDESEWERSSHALLNOTBE BACKFILLEDUNTILTHEPIPEHASBEENINSPECTEDAND APPROVEDANDTHELOCATIONANDDEPTHISRECORDED BYTHEPARKSENGINEER.
13.PIPE12"DIAMETERANDLARGERTOBEABANDONED SHALLBEFILLEDWITHPORTLANDCEMENTANDSAND MIXTURE.SEESPECIFICATIONS.
14.THECONTRACTORSHALLPROVIDESUPPORTSFOR POWERPOLESNEAREXCAVATIONSPERSEATTLECITY LIGHTSTANDARDSNO.D3-6.
GENERALCONSTRUCTION EROSION/SEDIMENTATIONCONTROL(ESC)NOTES
1.CONSTRUCTIONEROSIONCONTROLMEASURESMUSTBEIN PLACEANDAPPROVEDBYTHEPARKSENGINEERPRIORTO ANYEARTHDISTURBANCE.CALL206/684-8860TOSCHEDULE ANINSPECTIONAPPOINTMENTFORTHISTIME.
2.THECONTRACTORSHALLPROVIDEANDMAINTAIN TEMPORARYSEDIMENTATIONCOLLECTIONFACILITIESTO ENSURETHATSEDIMENT-LADENWATERDOESNOTENTER THENATURALORPUBLICDRAINAGESYSTEM.AS CONSTRUCTIONPROGRESSESANDUNEXPECTED (SEASONAL)CONDITIONSDICTATE,MORESILTATION CONTROLFACILITIESMAYBEREQUIREDTOENSURE COMPLETESILTATIONCONTROLOFTHEPROJECT. THEREFORE,DURINGTHECOURSEOFCONSTRUCTIONIT SHALLBETHEOBLIGATIONANDRESPONSIBILITYOFTHE CONTRACTORTOADDRESSANYNEWCONDITIONSTHATMAY BECREATEDBYHISACTIVITIESANDTOPROVIDEADDITIONAL FACILITIESTHATMAYBENEEDEDTOPROTECTADJACENT PROPERTIES.
3.THEIMPLEMENTATIONOFTHESEESCPLANSANDTHE CONSTRUCTION,MAINTENANCE,REPLACEMENTAND UPGRADINGOFTHESEESCFACILITIESISTHE RESPONSIBILITYOFTHECONTRACTORUNTILALL CONSTRUCTIONISAPPROVED.
4.IFTHEBOUNDARIESOFTHEENVIRONMENTALLYCRITICAL AREALIMITSARESHOWNONTHEPLANS,THEYSHALLBE CLEARLYFLAGGEDINTHEFIELDPRIORTOCONSTRUCTION. DURINGTHECONSTRUCTIONPERIOD,NODISTURBANCE BEYONDTHEFLAGGEDLIMITSSHALLBEPERMITTED.THE FLAGGINGSHALLBEMAINTAINEDBYTHECONTRACTORFOR THEDURATIONOFCONSTRUCTION.
5.THEESCFACILITIESSHOWNONTHISPLANMUSTBE CONSTRUCTEDINCONJUNCTIONWITHALLCLEARINGAND GRADINGACTIVITIES,ANDINSUCHAMANNERASTOENSURE THATSEDIMENTLADENWATERDOESNOTENTERTHE DRAINAGESYSTEMORVIOLATEAPPLICABLEWATER STANDARDS.
6.THEESCFACILITIESSHOWNONTHISPLANARETHEMINIMUM REQUIREMENTSFORANTICIPATEDSITECONDITIONS. DURINGTHECONSTRUCTIONPERIOD,THESEESCFACILITIES SHALLBEUPGRADED(E.G.ADDITIONALSUMPS,RELOCATION OFDITCHESANDSILTFENCES,ETC.)ASNEEDEDFOR UNEXPECTEDSTORMEVENTS.
7.THEESCFACILITIESSHALLBEINSPECTEDDAILYBYTHE CONTRACTORANDMAINTAINEDASNECESSARYTOENSURE THEIRCONTINUEDFUNCTIONING.
8.ANYAREASTRIPPEDOFVEGETATION,INCLUDINGROADWAY EMBANKMENTS,WHERENOFURTHERWORKISANTICIPATED FORAPERIODOF15DAYS,SHALLBEIMMEDIATELY STABILIZEDWITHTHEAPPROVEDESCMETHODS(E.G. SEEDING,MULCHING,NETTING,EROSIONBLANKETS,ETC.).
9.ANYAREANEEDINGESCMEASURE,NOTREQUIRING IMMEDIATEATTENTION,SHALLBEADDRESSEDWITHIN FIFTEEN(15)DAYS.
10.THEESCFACILITIESONINACTIVESITESSHALLBEINSPECTED ANDMAINTAINEDAMINIMUMOFONCEAMONTHORWITHIN THE48HOURSFOLLOWINGASTORMEVENT.
11.ATNOTIMESHALLMORETHANONEFOOTOFSEDIMENTBE ALLOWEDTOACCUMULATEWITHINACATCHBASIN.ALL CATCHBASINSANDCONVEYANCELINESSHALLBECLEANED PRIORTOPAVING.THECLEANINGOPERATIONSHALLNOT FLUSHSEDIMENTLADENWATERINTOTHEDOWNSTREAM SYSTEM.
12.STABILIZEDCONSTRUCTIONENTRANCESANDWASHPADS SHALLBEINSTALLEDATTHEBEGINNINGOFCONSTRUCTION ANDMAINTAINEDFORTHEDURATIONOFTHEPROJECT. ADDITIONALMEASURESMAYBEREQUIREDTOENSURETHAT ALLPAVEDAREASAREKEPTCLEANFORTHEDURATIONOF THEPROJECT.
4.CONSTRUCTSTABILIZEDCONSTRUCTIONENTRANCE.
5.CLEARANDGRUBAREA.
6.REMOVEEXISTINGPAVEMENT,SURFACEFEATURES ANDMISCELLANEOUSITEMSASNOTED.
7.COORDINATEREMOVALANDCAPPINGOFEXISTING UTILITYLINESWITHAPPROPRIATEPURVEYOR.
8.GRADESITEPERPLAN.
9.STABILIZEGRADEDAREASWITHTEMPORARYEROSION CONTROLMEASURESASREQUIRED.
10.CONSTRUCTSITEIMPROVEMENTS.
11.MULCHREMAININGDISTURBEDAREASAND COORDINATEWITHFINALPAVINGANDPLANTING.
12.RETURNSILTATIONCONTROLAREASTOORIGINAL GROUNDCONDITIONS.
13.REMOVEREMAININGTEMPORARY EROSION/SEDIMENTATIONCONTROLONLYAFTERSITE HASBEENSTABILIZEDANDCITYOFSEATTLEDCISITE INSPECTORORPARKSENGINEERHASAPPROVEDTHE REMOVAL.
GENERALDEMOLITIONNOTES
1.SALVAGEABLEORRE-USABLEITEMSENCOUNTEREDIN THEFIELDBUTNOTIDENTIFIEDONTHISPLANSHALLBE OFFEREDTOTHEENGINEERFORSALVAGEPRIORTO DISPOSAL.IFDECLINEDBYENGINEER,ALL DEMOLISHEDITEMSSHALLBEDISPOSEDOFLEGALLY OFFSITE.
2.PROTECTALLFACILITIESNOTIDENTIFIEDFOR DEMOLITIONINCLUDINGBUTNOTLIMITEDTO:BURIED ELECTRICALLINES,IRRIGATIONSYSTEM,STORM SEWERLINES,TELEPHONELINES,CATCHBASINS, TREES,FENCING,FURNITURE,ETC.
3.KEEPALLWALKWAYSCLEARANDFREEOFDEBRIS. VEGETATEDANDPAVEDSURFACESTHATARE DAMAGEDDURINGCONSTRUCTIONSHALLBEREPAIRED TOTHESATISFACTIONOFTHEENGINEERATNOCOST TOTHEENGINEER.
4.COORDINATEDEMOLITIONOFELECTRICAL,LIGHTING ANDIRRIGATIONSYSTEMELEMENTSWITHNEW ELECTRICAL,LIGHTINGANDIRRIGATIONSYSTEMSPER PLANSANDSPECIFICATIONS.
5.DEMOLISHONLYTOEXTENTREQUIREDTO ACCOMMODATETHEWORKOFTHECONTRACT.
GENERALSURVEYNOTES
1.NOWARRANTYORGUARANTEEOFACCURACYOR COMPLETENESSISEITHERIMPLIEDOREXPRESSEDFOR EXISTINGUNDERGROUNDUTILITIESANDIMPROVEMENTS SHOWNONTHESECONSTRUCTIONDOCUMENTS.THEY AREPROVIDEDHEREINFORTHEPURPOSEOF ASSISTINGTHECONTRACTORINLOCATINGSAID UTILITIESANDIMPROVEMENTSINTHEFIELD.THE CONTRACTORSHALLBERESPONSIBLEFORCHECKING WITHAPPROPRIATEAGENCIESTHATMAYHAVE UNDERGROUNDUTILITIESANDIMPROVEMENTSWITHIN THEPROJECTLIMITSANDFORCHECKINGLOCATIONSIN THEFIELD.THECONTRACTORSHALLBESOLELY RESPONSIBLEFORANYANDALLDAMAGETO UNDERGROUNDUTILITIESANDIMPROVEMENTS RESULTINGFROMHISOPERATION.
GENERALWATERSERVICENOTES
1.DOMESTICWATERSERVICELINESSHALLBEINSTALLED WITHAMINIMUMOF24"OFCOVER.
2.ALLWATERSERVICEPIPINGONPROPERTYMUSTBE INSPECTEDPRIORTOBACKFILLINGTRENCH.
3.FORINFORMATIONANDINSPECTION,PHONEWATER SERVICEAT684-5800.COORDINATEWITHPARKS PLUMBINGSHOP.
4.COORDINATEWORKWITHSPUANDPARKSPLUMBING SHOP.
13.WHERESEEDINGFORTEMPORARYEROSIONCONTROLIS REQUIRED,FASTGERMINATINGGRASSESSHALLBEAPPLIED ATANAPPROPRIATERATE(E.G.ANNUALORPERENNIALRYE APPLIEDATAPPROXIMATELY80POUNDSPERACRE).
14.WHERESTRAWMULCHFORTEMPORARYEROSIONCONTROL ISREQUIRED,ITSHALLBEAPPLIEDATAMINIMUMTHICKNESS OFTWOINCHES.
15.PROVIDEPERMANENTEROSIONCONTROLSYSTEM. LANDSCAPEALLEXPOSEDEARTHSURFACESWITHSUITABLE VEGETATIONTOPREVENTEROSION.(25.09.060C.2)
GENERALEROSIONCONTROL/CONSTRUCTION SEQUENCE
1.ARRANGEANDATTENDPRE-CONSTRUCTION MEETINGWITHOWNEROROWNER'SREP. ANDSEATTLEDCISITEINSPECTORORPARKS ENGINEER.
2.CONTRACTOR'SSURVEYORTOESTABLISH ANDSTAKEOUTCONTROLPOINTSFORWORK.
3.ERECTSTRAWWATTLES,SILTFENCE,AND INLETPROTECTION.
CODEINFORMATIONSUMMARY
SBCTABLE601/602
MAX.TRAVELDISTANCE=58' ALLOWABLE=250'
EXTERIOR INTERIOR
D.FLOORCONSTRUCTION
E.ROOFCONSTRUCTION
FIRE-RESISTANCERATEDCONSTRUCTION REQUIREDSEPARATIONOFOCCUPANCIES A-3&BOCCUPANCY
SBC508.4EXCEPTION1
A-3&S-1OCCUPANCY ACCESSORYOCCUPANCY SBC508.2.4
MEANSOFEGRESS EXITACCESS
TRAVELDISTANCE=47' MAX.ALLOWABLE=300'
MINIMUMACCESSWIDTH
OCCUPANCYLOADCALCULATIONS EXITACCESSTRAVELDISTANCE-WITHSPRINKLERSYSTEM

SBCSECTION1005 STAIRWAYS-OCCUPANTLOADX0.2INCHES=>32"
OTHERCOMPONENTOCCUPANTLOADX0.15INCHES=>32"
MAX.TRAVELDISTANCE=41' ALLOWABLE=250'
TRAVELDISTANCE=36' MAX.ALLOWABLE=250'
-MINIMUMNUMBEROFEXITSORACCESSPERSTORY
CORRIDORS/HALLWAY CORRIDORFIRE-RESISTANCERATING IBCTABLE1020.1 SBCTABLE1020.1 OCCUPANCY:A,B&S OCCUPANTLOADSERVEDBYCORRIDOR:GREATERTHAN30 REQUIREDFIRE-RESISTANCERATING(PERHOUR) WITHSPRINKLERSYSTEM: 0HOUR
DEMOLITIONLEGEND
EXISTINGTOBEDEMOLISHED. EXISTINGTOREMAIN. EXISTINGFLOORFINISHTOBEDEMOLISHED.
EXISTINGCEILINGTOBEDEMOLISHED
PLANFLAGNOTES
GENERALNOTES
1.THECONTRACTORSHALLFIELDVERIFYALLEXISTINGCONDITIONS PRIORTOTHECOMMENCEMENTOFWORK.ANYDISCREPANCIES SHALLBEBROUGHTTOTHEATTENTIONOFTHEARCHITECT IMMEDIATELY.
2.ITISCONTRACTOR'SRESPONSIBILITYTOLOCATEALLMECHANICAL, ELECTRICAL&MISCELLANEOUSEQUIPMENTREQUIREDTOBE REMOVED.REFERTOMECHANICAL&ELECTRICALDRAWINGSFOR ADDITIONALDEMOLITIONUNDEREACHDISCIPLINE.
3.THEOWNERHASTHERIGHTTOSALVAGEALLREMOVEDITEMS. ITEMSNOTCLAIMEDBYTHEOWNERSHALLBECOMETHE CONTRACTOR'SPROPERTYANDSHALLBEPROMPTLYREMOVED FROMSITE.MATERIALSTOBEREMOVEDANDREUSEDAS IDENTIFIEDINTHEDRAWINGSSHALLBESTOCKPILEDAND PROTECTED.
D1a DEMOEXISTINGRELIGHT.
D1b DEMOEXISTINGWALLFOROPENING. SEEA6.01FORSIZE.PREPAREAS NECESSARYFORPLACEMENTOFNEW FINISH.
DEMOEXISTINGPLUMBINGFIXTURES,CAP UTILITIESPERMECHANICAL/PLUMBING DRAWINGS.PATCH&REPAIRASNECESSARY FORPLACEMENTOFNEWFINISH.
DEMOEXISTINGCARPET&VCTFINISH.
DEMOEXISTINGFULLHEIGHTSTUDWALL. PREPAREASNECESSARYFOR PLACEMENTOFNEWFINISH. DEMOEXISTINGDOOR&FRAME.
D5 DEMOWALLS,PREPAREASNECESSARYFOR PLACEMENTOFNEWFINISH.
D6 DEMOEXISTINGHMDOOR,SIDEFRAMEPANELS, ACCESS&FIREALARMPANELS.
D7 DEMOEXISTINGTOILETSTALLPARTITIONS& DOORS
D8 DEMOPLUMBINGFIXTURES.SALVAGE& RELOCATEASNEEDED.
D9 DEMOSTALLPARTITIONS.
D10 DEMOEXISTINGCASEWORK&COUNTER.
D11 DEMOEXISTINGCONCRETEENTRYRAMP&STAIRS& STEELSTAIRS.
D12 DEMOEXISTINGWINDOWS,FRAMES&TRIM
D13 DEMOEXISTINGSTOREFRONTSYSTEM
D14 DEMOMARBLETHRESHOLD
D15 DEMODRINKINGFOUNTAIN
D16 DEMOEXISTINGPLUMBINGFIXTURES
D17 DEMOEXISTINGMOPSINK
D18 REMOVEEXISTINGWOODFLOORAS REQUIREDFORSTRUCTURAL.REMOVE FLOORINGBOARDSINPATTERNFOR REINSTALLINGNEW.
D19 REMOVEBASKETBALLHOOPS,EXISTING PULLEYSYSTEM&COUNTERWEIGHTSNOT INUSE.SALVAGEHOOP,BACKBOARD& SUPPORTSTRUCTUREFORREINSTALLATION
D23 REMOVEANDSALVAGEFIREPANELFOR RELOCATIONSEEELECTRICAL
D24 REMOVELIGHTSWITCH,PATCHWALL. PREPARETOREINSTALLINACCESSIBLE LOCATION
CEILINGFLAGNOTES
DEMOEXISTINGCEILINGTILETOSTRUCTURE
D21
4.PROVIDETEMPORARYSTRUCTURALSUPPORTASREQUIREDFOR DEMOLITION&CONSTRUCTION.
5.ALLOWNODEBRISTOACCUMULATEONTHESITE.
6.LEAVEALLSURFACESINSUITABLECONDITIONSFORNEWWORK.
7.NOTIFYUTILITYCOMPANIESASREQUIRED.CAPOFFABANDONED UTILITYLINESSOTHEYARECONCEALEDINTHENEWWORK.
8.ALLDEMOLITIONWORKTOCOMPLYWITHALLAPPLICABLECODES INCLUDINGNOISE,TRAFFIC,DUST,FIRE&SAFETY.ERECT TEMPORARYBARRIERSASREQUIREDBYCODE.
9.ANYVOIDS,HOLES,LEFTINEXISTINGCONSTRUCTIONTOREMAIN DUETODEMOLITIONFORNEWWORKSHALLBEFILLED,PATCHED& FINISHEDTOMATCHEXISTINGADJACENTCONSTRUCTION& SURFACESTOREMAIN.
10.SEEELEC.,STRUCT.,MECHANICAL,&PLUMBINGDRAWINGSFOR DEMOLITIONWORKOFSTRUCTURALANDELECTRICALITEMS.
11.CONTRACTORTOPRESERVEANDPROTECTTHESURFACES/ STRUCTURETHATARETOREMAIN.ANYDAMAGESHALLBE REPAIREDORREPLACEDASDIRECTEDATTHECONTRACTOR'S EXPENSE.
12.FLOORDRAINSINRM113ANDRM115TOBEDEMO'EDANDFLOOR PATCHEDANDREPAIRED.
D22 PARTIALLYREMOVEEXISTINGCEILINGAS NEEDEDFORSTRUCTURAL&INSTALLATION OFSTRUCTURALFRAME.
CEILINGFLAGNOTES
DEMOEXISTINGCEILINGTILETOSTRUCTURE
D22 PARTIALLYREMOVEEXISTINGCEILINGAS NEEDEDFORSTRUCTURAL&INSTALLATION OFSTRUCTURALFRAME.
DEMOLITIONLEGEND EXISTINGTOBEREMOVED. EXISTINGTOREMAIN. EXISTINGFLOOR FINISHTOBEREMOVED
EXISTINGCEILINGTOBEDEMOLISHED
GENERALNOTES
1.THECONTRACTORSHALLFIELDVERIFYALLEXISTING CONDITIONSPRIORTOTHECOMMENCEMENTOF WORK.ANYDISCREPANCIESSHALLBEBROUGHTTO THEATTENTIONOFTHEARCHITECTIMMEDIATELY.
2.ITISCONTRACTOR'SRESPONSIBILITYTOLOCATEALL MECHANICAL,ELECTRICAL&MISCELLANEOUS EQUIPMENTREQUIREDTOBEREMOVED.REFERTO MECHANICAL&ELECTRICALDRAWINGSFOR ADDITIONALDEMOLITIONUNDEREACHDISCIPLINE.
3.THEOWNERHASTHERIGHTTOSALVAGEALL REMOVEDITEMS.ITEMSNOTCLAIMEDBYTHE OWNERSHALLBECOMETHECONTRACTOR'S PROPERTYANDSHALLBEPROMPTLYREMOVED FROMSITE.MATERIALSTOBEREMOVEDAND REUSEDASIDENTIFIEDINTHEDRAWINGSSHALLBE STOCKPILEDANDPROTECTED.
4.PROVIDETEMPORARYSTRUCTURALSUPPORTAS REQUIREDFORDEMOLITION&CONSTRUCTION.
5.ALLOWNODEBRISTOACCUMULATEONTHESITE.
6.LEAVEALLSURFACESINSUITABLECONDITIONSFOR NEWWORK.
7.NOTIFYUTILITYCOMPANIESASREQUIRED.CAPOFF ABANDONEDUTILITYLINESSOTHEYARECONCEALED INTHENEWWORK.
8. ALLDEMOLITIONWORKTOCOMPLYWITHALL APPLICABLECODESINCLUDINGNOISE,TRAFFIC, DUST,FIRE&SAFETY.ERECTTEMPORARYBARRIERS ASREQUIREDBYCODE.
9.ANYVOIDS,HOLES,LEFTINEXISTINGCONSTRUCTION TOREMAINDUETODEMOLITIONFORNEWWORK SHALLBEFILLED,PATCHED&FINISHEDTOMATCH EXISTINGADJACENTCONSTRUCTION&SURFACESTO REMAIN.
10.SEEELEC.STRUCT.,MECHANICAL,&PLUMBING DRAWINGSFORDEMOLITIONWORKOFSTRUCTURAL ANDELECTRICALITEMS.
11.CONTRACTORTOPRESERVEANDPROTECTTHE SURFACES/STRUCTURETHATARETOREMAIN.ANY DAMAGESHALLBEREPAIREDORREPLACEDAS DIRECTEDATTHECONTRACTOR'SEXPENSE.
PLANFLAGNOTES
Also,verifyallundergroundutilitiesnotlocatedbythe 811servicebyusingacommerciallocationserviceand callSPRInspectionRequestLine(206)684-7034.
DEMOLISHEXISTINGPLUMBINGFIXTURES,CAP UTILITIESASPERMECHANICAL/PLUMBING DRAWINGS.PATCHANDREPAIRASNECESSARY FORPLACEMENTOFNEWFINISH.

DEMOEXISTINGFLOORFINISH.
DEMOEXISTINGFULLHEIGHTSTUDWALL. PREPAREASNECESSARYFORPLACEMENTOF NEWFINISH. DEMOEXISTINGDOORANDFRAME.
D5 NOTUSED
D6 NOTUSED
D7 NOTUSED
D8 DEMOPLUMBINGFIXTURES.
D9 DEMOSTALLPARTITIONS.
D10 DEMOEXISTINGCASEWORKANDCOUNTER.
D18 REMOVEEXISTINGWOODFLOORASREQUIRED BYSTRUCTURAL.REMOVEFLOORINGBOARDSIN PATTERNFORREINSTALLINGNEW.
D19 REMOVEBASKETBALLHOOPS,EXISTINGPULLEY SYSTEM&COUNTERWEIGHTSNOTINUSE. SALVAGEHOOP,BACKBOARD&SUPPORT STRUCTUREFORREINSTALLATION
D20 REMOVEWALLSYSTEMANDPREPAREFORNEW WINDOWS.
SECONDLVLDEMOPLAN
GENERALNOTES
1.THECONTRACTORSHALLFIELDVERIFYALLEXISTING CONDITIONSPRIORTOTHECOMMENCEMENTOF WORK.ANYDISCREPANCIESSHALLBEBROUGHTTO THEATTENTIONOFTHEENGINEERIMMEDIATELY.
2.ITISCONTRACTOR'SRESPONSIBILITYTOLOCATEALL MECHANICAL,ELECTRICAL&MISCELLANEOUS EQUIPMENTREQUIREDTOBEREMOVED.REFERTO MECHANICAL&ELECTRICALDRAWINGSFOR ADDITIONALDEMOLITIONUNDEREACHDISCIPLINE.
3.THEOWNERHASTHERIGHTTOSALVAGEALL REMOVEDITEMS.ITEMSNOTCLAIMEDBYTHE OWNERSHALLBECOMETHECONTRACTOR'S PROPERTYANDSHALLBEPROMPTLYREMOVED FROMSITE.MATERIALSTOBEREMOVEDAND REUSEDASIDENTIFIEDINTHEDRAWINGSSHALLBE STOCKPILEDANDPROTECTED.
4.PROVIDETEMPORARYSTRUCTURALSUPPORTAS REQUIREDFORDEMOLITION&CONSTRUCTION.

5.ALLOWNODEBRISTOACCUMULATEONTHESITE.
6.LEAVEALLSURFACESINSUITABLECONDITIONSFOR NEWWORK.
7.NOTIFYUTILITYCOMPANIESASREQUIRED.CAPOFF ABANDONEDUTILITYLINESSOTHEYARECONCEALED INTHENEWWORK.
8.ALLDEMOLITIONWORKTOCOMPLYWITHALL APPLICABLECODESINCLUDINGNOISE,TRAFFIC, DUST,FIRE&SAFETY.ERECTTEMPORARYBARRIERS ASREQUIREDBYCODE.
9.ANYVOIDS,HOLES,LEFTINEXISTINGCONSTRUCTION TOREMAINDUETODEMOLITIONFORNEWWORK SHALLBEFILLED,PATCHED&FINISHEDTOMATCH EXISTINGADJACENTCONSTRUCTION&SURFACESTO REMAIN.
10.SEEELEC.STRUCT.,MECHANICAL,&PLUMBING DRAWINGSFORDEMOLITIONWORKOFSTRUCTURAL ANDELECTRICALITEMS.
11.CONTRACTORTOPRESERVEANDPROTECTTHE SURFACES/STRUCTURETHATARETOREMAIN.ANY DAMAGESHALLBEREPAIREDORREPLACEDAS DIRECTEDATTHECONTRACTOR'SEXPENSE.
PLANFLAGNOTES
DEMOEXISTINGSINGLEPLYROOFANDRIGID INSULATIONDOWNTOPLYWOODDECK(BID ADDITIVE02)
D31 DEMOEXISTINGASPHALTROOFSHINGLESTO PLYWOODDECK(BIDADDITIVE02).
D32 DEMOMEMBRANEROOFBETWEENBOTTOMOF SHINGLESANDPARAPETTYPAROUNDENTIRE PERIMETER(BIDADDITIVE02)
D33 DEMOMEMBRANEROOFING(BIDADDITIVE02)
D34 DEMOPARAPETFLASHING.COORDINATEWITH NEWWORK.
D35 REMOVEEQUIPMENT.RAISECURB.REINSTALL EQUIPMENT.COORDINATEWITHNEWWORK. (BIDADDITIVE-02)
DEMOLITIONLEGEND EXISTINGTOBEREMOVED.
ELEVATIONSDEMONOTES
DEMO(E)CONCRETECANOPY,(E0TOPCONCRETE FIN&INSTALLNEW.SEESTRUCTURAL.
REMOVE(E)CONC.FIN.REPAIR&PATCH(E) BRICKWALL.SEESTRUCTURAL.

DEMOSTOREFRONT.
REMOVE(E)HANDRAIL&CONCRETERAMP
REMOVE(E)ASPHALTSHINGLEROOF.(BIDADDITIVE02)
1.NOTUSED
2.ITSHALLBETHERESPONSIBILITYOFTHE CONTRACTORTOCOORDINATETHELOCATION OFTHEEXISTINGUTILITIESWITHTHECITYOF SEATTLEANDRESPECTIVEUTILITYCOMPANIES.
3.NOTUSED
4.SITEPLANPROVIDEDFORINFORMATIONUSE ONLYANDISNOTAREPRESENTATIONOFAN ACTUALSURVEY.
5.THECONTRACTORSHALLHAVEPERMISSIONTO USETHEEXISTINGCOMMUNITYCENTER EXISTINGPARKINGLOTFORPARKING,STAGING ANDMATERIALLAY-DOWN.THECONTRACTOR SHALLCOORDINATEAREASTOBEUSEDWITH THEOWNERPRIORTOMOBILIZATION.PORTIONS OFTHELOTWILLRESERVEDFORTHEOWNER TEMPORARYMOBILESTORAGEUNITS.
PRELIMINARYSITEPLAN

PROJECTNAME:
HIAWATHACOMMUNITYCENTER
ADDRESSOFPROPERTY 2700CALIFORNIAAVESW,SEATTLE,WA98116
OWNER CITYOFSEATTLEDEPARTMENTOFFINANCE&
ADMINISTRATIVESERVICES
LEGALDESCRIPTION: "PARCELB"SEATTLELOTBOUNDARYADJUST NO2401073RECNO20050316900014BEINGA
POROFSW1/4OFSE1/4STR11-24-03
PLatBlock:
PlatLot:
KINGCOUNTYPARCELNUMBER ParcelNo.:112403-9001
LEGEND
BUILDINGAREASTOBEREMODELED
PROPERTYLINE
PROPERTYLINECORNER
SETBACKLINE
STREETCENTERLINE
SEECIVILDRAWINGSFORFORMOREDETAILS.
SITEPLAN

GENERALNOTES
1.PROVIDEBLOCKINGINWALLSFOREQUIPMENT& ACCESSORIESASREQUIRED.
2.SEEELECTRICAL,STRUCTURAL.MECHANICAL ANDPLUMBINGDRAWINGSFORMORE INFORMATION.
3.OCCUPANCYLOADSTOBEPOSTEDNEAREXIT DOORWAYS.SEESPECIFICATIONSFORDETAILS.
FLOORPLANNOTES
PREPAREAREAFORINSTALLATIONOFNEW RECEPTIONDESK.SEESHEETA-509,INTERIOR ELEVATIONS,DETAILS,&ELECTRICAL
PREPAREAREAFORINSTALLATIONOFNEW CASEWORK.SEESHEETA-507,INTERIOR ELEVATIONS,DETAILS,&ELECTRICAL
3 HANDRAILSPERDETAILSSHEETA-505
REINSTALLSALVAGEDFIREPANEL,SEE ELECTRICAL
NOTUSED
RELOCATELIGHTSWITCHTOACCESSIBLE HEIGHT.(15"40"TYPICAL).SEEELECTRICAL
REMOVE&REINSTALL(E)SIGNORREINSTALL SIGN,REFERTOINTERIORELEVATIONS
INSTALLMOTORIZEDDIVIDERCURTAIN, SEESHEETA-408
9 PATCHWOODFLOOR.STAGGERBOARDSAND STITCHINTOFLOORBOARDLAYOUT.REFINISH FLOORPERFINISHSCHEDULE.AREASHOWNIS FORGENERALREFERENCE.CONTRACTORTO DETERMINESCOPEOFWORKBASEDON STRUCTURAL
>>>>CAUTION-CALL811<<<<
UTILITYNOTIFICATIONCENTER BEFOREYOUDIG! WWW.CALL811.COM
Also,verifyallundergroundutilitiesnotlocatedbythe 811servicebyusingacommerciallocationserviceand callSPRInspectionRequestLine(206)684-7034.
LEGEND
WALLCONSTRUCTION
PERMITSETCYCLE2 RESPONSE MARCH29.2021
6250
REGISTERED ARCHITECT

AlexE.Rolluda
STATEOFWASHINGTON
HIAWATHACOMMUNITYCENTER
STABILIZATION
NEWWINDOW(BIDADDITIVE03DOESNOT INCLUDESTOREFRONTSYSTEM) WX
1
GENERALNOTES
2.SEEELECTRICAL,STRUCTURAL.MECHANICAL ANDPLUMBINGDRAWINGSFORMORE INFORMATION.
3.OCCUPANCYLOADSTOBEPOSTEDNEAREXIT DOORWAYS.SEESPECIFICATIONSFORDETAILS.
FLOORPLANNOTES

CLOSEEXISTINGDOOROPENING.
4
REMOVE&REINSTALL(E)SIGNORREINSTALL SIGN,REFERTOSHEETA-501&INTERIOR ELEVATIONS
LEGEND
WALLCONSTRUCTION
EXISTINGCONSTRUCTIONTOREMAIN
PORTABLEWHEELCHAIRLIFT(FOIO) 10' 20' 30' 1SECONDFLOORPLAN SCALE1/8"=1'-0"
NEWDOOR NEWWINDOW(BIDADDITIVE03-DOESNOTINCLUDE STOREFRONTSYSTEM) WX
21
32
GENERALNOTES
1.ALLDIMENSIONS/EQUIPMENTANDVENTLOCATIONTO BEVERIFIEDATSITEANDANYDISCREPANCYISTOBE BROUGHTTOTHENOTICEOFTHEARCHITECT IMMEDIATELY.
FLAGNOTES
INSTALLSINGLEPLYROOFTYPER2.(BID ADDITIVE02)
INSTALLCOMPOSITESHINGLEROOFTYPER1. (BIDADDITIVE02)
INSTALLSINGLEPLYROOFBETWEENBOTTOMOFSHINGLE ANDPARAPETAROUNDENTIREPERIMETEROFBUILDING.(BID ADDITIVE02)

RAISEALLROOFTOPEQUIPMENTFORTHICKERINSULATION (BIDADDITIVE02) 33
REROOFLOWERROOFROOFTYPER3(BIDADDITIVE02) 34
RECLADEYEBROWROOFROOFTYPER3.(BIDADDITIVE02) 35
INSTALLROOFTYPETOMATCHEXISTING,TYP. 36
Also,verifyallundergroundutilitiesnotlocatedbythe
3.
GENERALNOTES
1.REFERTOSTRUCTURALDRAWINGSFORADDITIONAL DETAILS.
2.
EXTERIORELEVATIONSAREFORINFORMATIONAND WINDOWTYPEONLY.REFERTOWINDOWTYPE SCHEDULEFORWINDOWSIZES CONTRACTORTOREPLACEBRICKSREMOVEDFOR PURPOSEOFDESTRUCTIVEANALYSIS.SEENOTE46 (APPROXIMATELY4UNITSPERLOCATION)
ELEVATIONSNOTES
INSTALLNEWCONCRETECANOPY.SEE STRUCTURAL.PATCHANDREPAIRBRICKWORK 40
41
INSTALLNEWCONCRETEFIN.SEE STRUCTURAL.PATCHANDREPAIRBRICKWORK

42
STOREFRONTS&WINDOWS,SEESHEETSA-601&A-602
HANDRAILPERDETAILSSEESHEETA-505 43
ASPHALTSHINGLEROOF,SEEROOFTYPER1.(BIDADDITIVE 02) 44
45 RE-INSTALLSALVAGEDBRICK
46 REPLACEBRICKSATTHESEAPPROXIMATELOCATIONS
REPAIR,REPLACE, RE-MORTARALL MISSINGOR DAMAGEDBRICK.
REPAIR,REPLACE, RE-MORTARALL MISSINGOR DAMAGEDBRICK.
REPLACEALL WINDOWSPER PLANS& SCHEDULE

REPAIR,REPLACE, RE-MORTARALLMISSING ORDAMAGEDBRICK.
GENERALNOTES
1.REFERTOSTRUCTURALDRAWINGSFORADDITIONAL DETAILS.




EXTERIORELEVATIONSAREFORINFORMATIONAND WINDOWTYPEONLY.REFERTOWINDOWTYPE SCHEDULEFORWINDOWSIZES.REPLACEALL WINDOWS&FRAMESPERPLANSANDSCHEDULES.
CONTRACTORTOREPLACEBRICKSREMOVEDFOR PURPOSEOFDESTRUCTIVEANALYSIS. (APPROXIMATELY4UNITSPERLOCATION).
46 REPLACEBRICKSATTHESEAPPROXIMATELOCATIONS
GENERALNOTES
1.PROVIDEBLOCKINGINWALLFOR EQUIPMENTANDACCESSORIESAS REQUIRED.
2.READINCONJUNCTIONWITH ELECTRICAL/STRUCTURALDRAWINGS FORMOREINFORMATION.

3.SEEDETAIL1/A-501FORTYPICAL MOUNTINGHEIGHTSOFFIXTURESAND BRAILLE/TACTILESIGNAGELOCATION.
4.DIMENSIONSPROVIDEDAREFROM FACEOFSTUDEXCEPTTHOSEFROM EXISTINGWALLSANDSTRUCTURES UNLESSNOTEDOTHERWISE,WHERE THEYAREFROMFACEOFFINISH.
5.SEEFLOORPLANFORWINDOWTYPES.
6.OCCUPANCYLOADSTOBEPOSTED NEAREXITDOORWAYS.SEE SPECIFICATIONS.
LEGEND
GENERALNOTES
1.BRACEALLINTERIORPARTITIONSWITH DIAGONALBRACES@6'-0"O.C.ABOVE FINISHEDCEILING.
2.PROVIDEBLOCKINGINWALLFOR EQUIPMENTANDACCESSORIESAS REQUIRED.
3.FURNITURE,STATIONSANDWALL PARTITIONSAREINSTALLEDBYTHE MANUFACTURERANDARESHOWNIN ARCHITECTURALPLANONLYASA REFERENCE.
4.READINCONJUNCTIONWITH ELECTRICAL/STRUCTURALDRAWINGS FORMOREINFORMATION.

5.SEESHEETA8.03FORTYPICAL MOUNTINGHEIGHTSOFFIXTURESAND BRAILLE/TACTILESIGNAGELOCATION.
6.DIMENSIONSPROVIDEDAREFROM FACEOFSTUDEXCEPTTHOSEFROM EXISTINGWALLSANDSTRUCTURES UNLESSNOTEDOTHERWISE,WHERE THEYAREFROMFACEOFFINISH.
1ENTRANCELOBBY(ROOM100) SCALE1/4"=1'-0"
GENERALNOTES
1.BRACEALLINTERIORPARTITIONSWITH DIAGONALBRACES@6'-0"O.C.ABOVEFINISHED CEILING.
2.
PROVIDEBLOCKINGINWALLSFOREQUIPMENT& ACCESSORIESASREQUIRED.
3.SEEELECTRICAL,STRUCTURAL,MECHANICALAND PLUMBINGDRAWINGSFORMOREINFORMATION.

PROVIDEFILLERPIECEFORTOILET ACCESSORIESTHATBRIDGEBETWEENTILE& GWB.
RESTROOMACCESSORY
NOTUSED
GRABBAR
TOILETPAPERDISPENSER-SURFACE
WALLMOUNTEDWATERCLOSET
WALLMOUNTEDSINK
SOAPDISPENSER-SURFACEMOUNTED
WALLMOUNTEDURINAL
SHINGLES BABYCHANGINGSTATIONRECESSED
RECESSEDSANITARYNAPKINDISPOSAL
NOTE:PROVIDEFILLERPIECEFORTOILETACCESSORIESTHATBRIDGEBETWEENTILE&GWB.
1RR(ROOM115)
SCALE1/4"=1'-0"
GENERALNOTES
1.BRACEALLINTERIORPARTITIONSWITH DIAGONALBRACES@6'-0"O.C.ABOVEFINISHED CEILING.
2.
>>>>CAUTION-CALL811<<<<
PROVIDEBLOCKINGINWALLSFOREQUIPMENT& ACCESSORIESASREQUIRED.
3.SEEELECTRICAL,STRUCTURAL,MECHANICALAND PLUMBINGDRAWINGSFORMOREINFORMATION.
5.INSTALLROBEHOOKATEVERYSINGLEUSER TOILETANDTOILETSTALL.
RESTROOMACCESSORY LEGEND
SANITARYNAPKINDISPOSAL
GRABBAR
TOILETPAPERDISPENSER-SURFACE
MOUNTED
WALLMOUNTEDWATERCLOSET
WALLMOUNTEDSINK
MIRROR
SOAPDISPENSER-SURFACEMOUNTED
WALLMOUNTEDURINAL
HANDDRYER
SHINGLES
BABYCHANGINGSTATIONRECESSED
SHARPSDISPOSAL M DIRECTIONOFTILING

2MEN'S(ROOM113)
SCALE1/4"=1'-0"
3ALL-GENDERRESTROOM(ROOM114)
SCALE1/4"=1'-0"
Also,verifyallundergroundutilitiesnotlocatedbythe 811servicebyusingacommerciallocationserviceand callSPRInspectionRequestLine(206)684-7034.
PERMITSETCYCLE2 RESPONSE MARCH29.2021
UTILITYNOTIFICATIONCENTER BEFOREYOUDIG! WWW.CALL811.COM 6250 REGISTERED ARCHITECT AlexE.Rolluda STATEOFWASHINGTON
HIAWATHACOMMUNITYCENTER
STABILIZATION
INTERIORELEVATIONS A-404
SCALE1/4"=1'-0"
GENERALNOTES
1.BRACEALLINTERIORPARTITIONSWITH DIAGONALBRACES@6'-0"O.C.ABOVEFINISHED CEILING.
2.
PROVIDEBLOCKINGINWALLSFOREQUIPMENT& ACCESSORIESASREQUIRED.
3.SEEELECTRICAL,STRUCTURALANDMECHANICAL DRAWINGSFORMOREINFORMATION.

4.INSTALLROBEHOOKATEVERYSINGLEUSER TOILETANDSTALL
Also,verifyallundergroundutilitiesnotlocatedbythe 811servicebyusingacommerciallocationserviceand callSPRInspectionRequestLine(206)684-7034.
SANITARYNAPKINDISPOSAL
GRABBAR
TOILETPAPERDISPENSER-SURFACE MOUNTED
WALLMOUNTEDWATERCLOSET
WALLMOUNTEDSINK
MIRROR
SOAPDISPENSER-SURFACEMOUNTED NOTUSED
HANDDRYER
SHINGLES
BABYCHANGINGSTATIONRECESSED
GENERALNOTES
1.BRACEALLINTERIORPARTITIONSWITHDIAGONALBRACES@6'-0"O.C.ABOVE FINISHEDCEILING.
2.
PROVIDEBLOCKINGINWALLSFOREQUIPMENT&ACCESSORIESASREQUIRED.
3.SEEELECTRICAL,STRUCTURAL,MECHANICALANDPLUMBINGDRAWINGSFORMORE INFORMATION.

LEGEND
NOTUSED
HORIZONTALSTRONGBACKS,SEESTRUCTURAL
VERTICALSTRONGBACKS,SEESTRUCTURAL
SCOREBOARDLOWERED1'-0"TOACCOMMODATE
UPPERHORIZONTALSTRONGBACK MOTORIZEDDIVIDERCURTAIN,SEESHEETA-409.
RELOCATED(E)FIREALARMSWITCHBOX
MOTORIZEDBLINDS
MOTORIZEDBLINDSKEY-OPERATEDSWITCH
MOTORIZEDDIVIDERCURTAIN-KEY-OPERATED SWITCH
RELOCATEDCONDUIT&J-BOX
NOTUSED
2.
GENERALNOTES
1.BRACEALLINTERIORPARTITIONSWITH DIAGONALBRACES@6'-0"O.C.ABOVEFINISHED CEILING. PROVIDEBLOCKINGINWALLSFOREQUIPMENT& ACCESSORIESASREQUIRED.
3.SEEELECTRICAL,STRUCTURAL,MECHANICALAND PLUMBINGDRAWINGSFORMOREINFORMATION.

Also,verifyallundergroundutilitiesnotlocatedbythe 811servicebyusingacommerciallocationserviceand callSPRInspectionRequestLine(206)684-7034.
HORIZONTALSTRONGBACKS,SEESTRUCTURAL
SCOREBOARDLOWERED1'-0"TOACCOMMODATE UPPERHORIZONTALSTRONGBACK MOTORIZEDDIVIDERCURTAIN,SEESHEETA-409.
RELOCATED(E)FIREALARMSWITCHBOX
MOTORIZEDBLINDS
MOTORIZEDBLINDS-KEY-OPERATEDSWITCH
STRUCTURALHEADERCCHANNEL,SEE
GENERALNOTES
1.BRACEALLINTERIORPARTITIONSWITHDIAGONALBRACES@6'-0"O.C.ABOVEFINISHEDCEILING.
PROVIDEBLOCKINGINWALLSFOREQUIPMENT&ACCESSORIESASREQUIRED.
2.
3.SEEELECTRICAL,STRUCTURAL,MECHANICALANDPLUMBINGDRAWINGSFORMOREINFORMATION. 1GYMNASIUM-DIVIDERCURTAININTERIORELEVATION
SCALE1/4"=1'-0"
BEFOREYOUDIG! WWW.CALL811.COM
PERMITSETCYCLE2 RESPONSE MARCH29.2021
3CEILINGSTRUCTURE@GYMDIVIDERCURTAIN SCALE11/2"=1'-0"
4CENTERBATTEN@GYMDIVIDERCURTAIN
SCALE11/2"=1'-0"
6250 REGISTERED ARCHITECT AlexE.Rolluda STATEOFWASHINGTON

5GYMFLOOR@GYMDIVIDERCURTAIN
SCALE11/2"=1'-0"
INTERIORELEVATIONS
2.
>>>>CAUTION-CALL811<<<<
GENERALNOTES
1.BRACEALLINTERIORPARTITIONSWITH DIAGONALBRACES@6'-0"O.C.ABOVEFINISHED CEILING. PROVIDEBLOCKINGINWALLSFOREQUIPMENT& ACCESSORIESASREQUIRED.
3.SEEELECTRICAL,STRUCTURAL,MECHANICALAND PLUMBINGDRAWINGSFORMOREINFORMATION.
LEGENDASINELEVATION
MOTORIZEDROLLINGCOUNTERDOOR, SEEDETAILS2-6/A502&SHEETA-518. A
UTILITYNOTIFICATIONCENTER BEFOREYOUDIG! WWW.CALL811.COM
Also,verifyallundergroundutilitiesnotlocatedbythe 811servicebyusingacommerciallocationserviceand callSPRInspectionRequestLine(206)684-7034.
PERMITSETCYCLE2 RESPONSE MARCH29.2021
6250
REGISTERED ARCHITECT

AlexE.Rolluda STATEOFWASHINGTON
HIAWATHACOMMUNITYCENTER
STABILIZATION
INTERIORELEVATIONS
1.WHERE"*"ISINDICATEDTOECLEARANCEATTHEFRONTOFTHEPARTITIONISNOTREQUIREDINACOMPARTMENTGREATERTHAN62 DEEPWITHAWALL-HUNGWATERCLOSETOR65DEEPWITHAFLOOR-MOUNTEDWATERCLOSET.TOECLEARANCEATTHESIDEISNOT REQUIREDINACOMPARTMENTGREATERTHAN66WIDE.TOECLEARANCEISEXCLUSIVEOFPARTITIONSUPPORT MEMBERS.IFDEPTHOFSTALLISGREATERTHAN60,TOECLEARANCEDOESNOTAPPLY.
2.WHERE6ORMORESTALLSAREPROVIDED,INADDITIONTOSTANDARDSTALL,PROVIDEATLEAST1STALL36"WIDEWITHOUTSWINGING DOORANDDEPTHOFSTALLASREQUIREDTOACCOMMODATELENGTHOFGRABBAR.STALLSHALLBEINACCORDANCETOAPPLICABLE ACCESIBILITYCODES
NOTE:REACHHEIGHTSPROVIDEDARETOOPERABLEPARTS
NOTE:X=12IFDOORHASBOTHACLOSERANDALATCH

JAMBBEYOND
DOORAS SCHEDULED, WEATHERSTRIP
ALUMINUM THRESHOLDSETIN SEALANTW/EXP. FASTENERS
>>>>CAUTION-CALL811<<<<
UTILITYNOTIFICATIONCENTER BEFOREYOUDIG! WWW.CALL811.COM
Also,verifyallundergroundutilitiesnotlocatedbythe 811servicebyusingacommerciallocationserviceand callSPRInspectionRequestLine(206)684-7034.
4'-0"TYP
PARTELEVATION NTS
COUNTERSUNK FASTENERS,EA.SIDE OFJOINT,EQUALSPACE @APPROX.6"OC
7COVEBASE SCALE6"=1'-0"
FACEOFWALL WALLTILEPER SCHEDULE COVEPROFILE, COLORTOMATCHTILE
FLOORTILEPER SCHEDULE
4'-0"
(E)WALLASSEMBLY
1X2FURRING@16"OC PAINTBLACK.
2X4WOODALIGNTO TOPOFWINDOWSILL, EASEEDGES
PLYWOODWAINSCOTPER SCHEDULE(FIRETREATED) JOINTSTOCOINCIDEWITH FURRINGSTRIPS
(E)FINFLOOR
2WAINSCOT@TEENROOM SCALE3/4"=1'-0"
TOPOFSECONDFLOOR EXISTINGFLOOR ASSEMBLY
BOTTOMOF(E) STRUCTURE (E)CEILINGWITH(E)FRAMING
CONTINUOUSSEALANT ATJOINT
3/4"PLY.PAINTTO MATCHCEILING
LEDLIGHTING
KNIFEEDGEPROFILE WITHLEDLIGHT
FLOORASSEMBLY
3
SEERCP
2X6@16O.C,FASTEN TOWALLWITH2X6 BLOCKING WALLASSCHEDULED
COVELIGHTING,TYP SCALE11/2"=1'-0"
GWBPERSCHEDULE. PAINTALLEXPOSED SURFACES
6250 REGISTERED ARCHITECT

AlexE.Rolluda STATEOFWASHINGTON
HIAWATHACOMMUNITYCENTER
STABILIZATION
DETAILS A-502
92 37
(E)WALL
REMOVE,REPLACE, REPOINTBRICK
PROVIDEWEEP HOLES
>>>>CAUTION-CALL811<<<< UTILITYNOTIFICATIONCENTER BEFOREYOUDIG! WWW.CALL811.COM
STAINLESSSTEEL FLASHING
PATCHBRICKVENEER ANDWEEP
H
WINDOWSILL@CONCCURB
PROSCOFASTFLASH,COAT TOPOFCONCRETE&UP/OUT ONTOSHEATHING CLEAT
6"
SHTMETALCOUNTERFLASHING, HEMMEDEDGE
RCCCANOPYSEE STRUCTURAL
(E)WALL& FLOORFRAMING
SHEETMETAL COUNTERFLASHING
Also,verifyallundergroundutilitiesnotlocatedbythe 811servicebyusingacommerciallocationserviceand callSPRInspectionRequestLine(206)684-7034.

COATPROSCOFAST FLASHOVERTOPOF CONCRETE&UP/OUT ONTOSHEATHING SHTMTLFLASHING, CLEAT&HEMMEDEDGE
1/4"x1/4"DRIP
RCCCANOPY,SEE STRUCTURAL
ALUM.FRAME EXPANDER&CLIPBY WINDOWMFR
WINDOWHEAD-SECONDFLOOR
METALCLADWOODBRICK MOULD
1/4"x1/4"DRIP ALUMEXTENDER&RECEIVER BYWINDOWMFR
ROD&SEALANT,TYP
WINDOWHEADER&FINFLASHING
SCALE3"=1'-0"
(E)CEILING@ ±9'-0"AFF
CEILING@8'-6", SEERCP
3/4"WOODTRIM FILLER
METALCLADWOOD FRAMEPERSCHEDULE
5WINDOW/DOORJAMB
APPLYFASTFLASH ONTOTOPOFRCC,AT ENDSANDUNDERSIDE. RETURNONSHEATHING. APPLYCONCEALEDBY BRICKORFLASHINGAT ALLLOCATIONS.
GLAZINGAS SCHEDULED WINDOW FRAMEBYMFR
SCALE3"=1'-0"
NOTE:BRICKANDFLASHINGNOT SHOWN CONDITIONWHERERCCEXTENDS BEHINDBRICKATENDSIM.
RCCCANOPY/FINFLASHING
WINDOWJAMB
SCALE3"=1'-0"
REMOVE,REPLACE, REPOINTBRICK
ROD&SEALANT,TYP
ALUMINUMCLAD
(E)MASONRYSILL
(E)WOODTRIM, PREPAREANDPAINT
SHIMS
(E)FRAMING ROD&SEALANT,TYP
FRAMEEXPANDER& CLIPBYWINDOWMFR H
WINDOWSILL
SCALE3"=1'-0"
WINDOW&FRAME PERSCHEDULE
PERMITSETCYCLE2 RESPONSE MARCH29.2021
(E)WOODTRIM, PREPAREANDPAINT
3/4"WOODTRIM
SHIM
WINDOW&FRAME
(E)FRAMING ROD&SEALANT,TYP
ALUM.FRAMEEXPANDER &CLIPBYWINDOWMFR
REMOVE,REPLACE, REPOINTBRICK
JAMBBEYOND
3/4"WOODSILL
3/4"WOODTRIMFILLER WINDOW&FRAME SHIMS
FLASHINGMEMBRANE
(E)WOODTRIM, PREPAREANDPAINT
(E)FRAMING
HIAWATHACOMMUNITYCENTER STABILIZATION
DETAILS-WINDOWS A-504
>>>>CAUTION-CALL811<<<<
COREDRILLALL POSTS&FILLWITH NON-SHRINKGROUT
Also,verifyallundergroundutilitiesnotlocatedbythe 811servicebyusingacommerciallocationserviceand callSPRInspectionRequestLine(206)684-7034.
#4REINFORCINGUBAR @EACHPOST COREDRILL4"DIAFILL WITHNONSHRINK GROUT

ENTRANCESTEPS&RAMP
ENTRANCERAMP
SCALE3/4"=1'-0"
COREDRILLALL
ENTRANCERAMPREVERSED
#4REINFORCINGUBARATEACHPOST COREDRILL4"DIAFILLWITHNONSHRINKGROUT
HANDRAIL@NORTHENDENTRYPLATFORM
NOTES:
1.ALLPIPESHALLBE1
1 2SCH40PIPE,GALVANIZEDSTEEL.
2.GRINDALLWELDEDJOINTSSMOOTH.
3.HOTDIPGALVANIZEDAFTERFABRICATION.
4.PIPESHALLFOLLOWALIGNMENTOFSTAIRNOSINGS.
5.PROVIDESHOPDRAWINGSBEFOREFABRICATION.
6.FORHANDRAILSLONGERTHAN50',PROVIDESLIPJOINT ADJACENTTOPOSTEVERY50',SPACEEVENLY.
7.EXTERNALVENTHOLESMUSTBEASCLOSETOTHEWELD ASPOSSIBLEANDMUSTBE25%THESIZEOFTHEI.D.OF THEPIPE,BUTNOTLESSTHAN3 8"INDIA.
8.VENTHOLESINENDSECTIONSORINSIMILARSECTIONS MUSTBE"INDIA.
9.ENDSSHOULDBELEFTCOMPLETELYOPEN.ANYDEVICE USEDFORFIELD-ERECTIONTHATPREVENTSFULL OPENINGSONENDSOFHORIZONTALRAILSANDVERTICAL LEGSSHOULDBEGALVANIZEDSEPARATELYAND ATTACHEDAFTERGALVANIZING.
HANDRAILNOTES
SCALE3/4"=1'-0"
DETAILS
SOLIDSURFACE COUNTERTOPAND BACKSPLASH
1/4"PLYWOODBACK PLAMFINISHINTHEINTERIOR
ADJUSTABLESHELF, TYP.PLAMFINISH
1/4"ØHOLES@2"O.C.TYP
3/4"PLYWOODDOOR PLAMFINISHINTERIOR ANDEXTERIOR
11/2"X4"S PLAMFINISHEXTERIOR
GWBCEILINGAS SCHEDULED WOODSHINGLES WALLASSCHEDULED

3/4"PLY BLACKENEDSTEELFLAT 1/8"X2"FASTENTO BLOCKING,GRINDEDGES
1/2"REVEAL COUNTERSUNKHEAD
LEDSTRIPLIGHT,SEE ELEC
COLUMNCLADDINGDETAIL
SOLIDSURFACE
5/8"GWB(PAINT) WITHJBEADATBOTH ENDS
PLYSHEATHINGPER STRUCTURAL
3/4"PLYWOOD 2X6FURRING@ 24"O.C.,TYP LEDSTRIPLIGHT.SEE ELEC
TOPOFSECONDFLOOR EXISTINGFLOOR ASSEMBLY
BOTTOMOF(E) STRUCTURE (E)CEILINGWITH(E)FRAMING
CONTINUOUSSEALANT ATJOINT
3/4"PLY.PAINTTO MATCHCEILING
LEDLIGHTING
KNIFEEDGEPROFILE WITHLEDLIGHT
SCHEDULEDBASE
1XWOODTRIM FINISHEDFLOORLEVEL
TOWALLWITH2X6 BLOCKING WALLASSCHEDULED
BASECABINET-ADASINK,TYP.
>>>>CAUTION-CALL811<<<< UTILITYNOTIFICATIONCENTER BEFOREYOUDIG! WWW.CALL811.COM
Also,verifyallundergroundutilitiesnotlocatedbythe 811servicebyusingacommerciallocationserviceand callSPRInspectionRequestLine(206)684-7034.

3/4"PLYWOODDOOR PLAMFINISH ADJUSTABLE SHELF,TYP.PLAMFINISH 3'-6" 3'-6" 3'-6" 3'-6"
PLAMFINISHINTHEINTERIOR
PERMITSETCYCLE2 RESPONSE MARCH29.2021
6250
3/4"ADJSHELF PLAMFINISH
HIAWATHACOMMUNITYCENTER STABILIZATION
DETAILS A-508
92 3PLAN-KITCHEN(ROOM208) SCALE3/4"=1'-0" 2SECTION-B SCALE11/2"=1'-0" 1SECTION-A SCALE11/2"=1'-0" 4ELEVATION-KITCHEN(ROOM208) SCALE3/4"=1'-0" 44
ALLEXPOSEDFACESOFCASEWORKTOHAVEPLAMFINISH.

(E)ROOFASSEMBLY ASPHALTSHINGLES UNDERLAYMENT (E)INSULATION (E)SHEATHING (E)DECKING
R1EXISTINGROOF
(BIDADDITIVE02)
R2ROOF
ROOFASSEMBLY -SINGLEPLY MEMBRANE
-1/4"COVERBOARD -TAPEREDPOLYISOINS. -R-38POLYISOINS. -SELF-ADHEREDVAPOR RETARDERTEMP ROOF -(E)SHEATHING -(E)DECKING
ROOFASSEMBLY -SINGLEPLYROOF MEMBRANE
-POLY-ISOINS.TAPERED W/3"BASELAYER -1/8"PLYWD
-21/2"X6"T&GSHTH'G -(E)FRAMING
R3LOWERROOF
(BIDADDITIVE02)
FSHEARWALL
GSHEARWALL
5/8"TYPEXEASIDE
1/2"PLYEASIDE,SEE STRUCTURAL WOODFRAMINGPER STRUCTURAL
>>>>CAUTION-CALL811<<<< UTILITYNOTIFICATIONCENTER BEFOREYOUDIG! WWW.CALL811.COM
2X4@16"O.C.,TYP
5/8"TYPEXEASIDE (1/2"TILEBACKER BOARD@TILEWALLS)
Also,verifyallundergroundutilitiesnotlocatedbythe 811servicebyusingacommerciallocationserviceand callSPRInspectionRequestLine(206)684-7034.
WOODFRAMINGPER STRUCTURAL SEEPLAN
5/8"TYPEX
SEEPLAN SEEPLAN
(E)GWB
INSTALLR-21FOAMED INSULATION (E)WOODFRAMING
(E)EXTERIORFINISH
(E)BRICKVENEER
HEXTERIORWALL
SEEPLAN
SEEPLAN SEEPLAN SEEPLAN
1/2"PLYEASIDE, SEESTRUCTURAL
5/8"TYPEXEASIDE (E)WOODFRAMING
IEXISTINGWALL
5/8"TYPEXEASIDE (1/2"TILEBACKER BOARD@TILEWALLS)
2X4@16"O.C.,TYP
JPLUMBINGCHASE
5/8"TYPEXEA SIDE
2X4@16"O.C., TYP
BPLUMBINGCHASE
2X6@16"O.C.
5/8"TYPEXEASIDE (1/2"TILEBACKER BOARD@TILEWALLS)
CINTERIORWALL
SEEPLAN
PERMITSETCYCLE2 RESPONSE MARCH29.2021
DFURRING
SEEPLAN
ATYP.INTERIOR EFURRING
2X4@16"O.C.
5/8"TYPEX
6250 REGISTERED ARCHITECT

AlexE.Rolluda STATEOFWASHINGTON
5/8"TYPEXEASIDE
2X6@16"O.C.
HIAWATHACOMMUNITYCENTER
STABILIZATION
WALL&ROOFTYPES
92 46
A-510

(BIDADDITIVE03) (BIDADDITIVE03) (BIDADDITIVE03) (BIDADDITIVE03) (BIDADDITIVE03)
Also,verifyallundergroundutilitiesnotlocatedbythe 811servicebyusingacommerciallocationserviceand callSPRInspectionRequestLine(206)684-7034.
