Harmer - SML Technical Brochure

Page 66

Above Ground Installation - Ductile Iron Coupling

1. Slacken the bolts on the Ductile Iron coupling, fully removing one bolt completely. Remove the EPDM rubber gasket.

2. Push the EPDM rubber gasket over the end of the pipe or fitting, ensuring that the central inner register is abutted against the spigot end.

3. Ease the next pipe or fitting into the EPDM rubber gasket making sure that the spigot end is against the central inner register.

4. Loosely fit the coupling around the gasket, ensuring that the rubber lip sits into the corresponding locator in the coupling. The electrical continuity screws should be drawn back to fullest extent to avoid interference with the connecting pipe or fitting.

5. Check the alignment of the assembly before tightening the bolts. Alternately, tighten the bolts to ensure that the coupling is aligned evenly. Bolts should be tightened until a reasonable resistance is achieved – recommended torque setting 22 Nm.

6. For electrical continuity, hand-tighten the electrical continuity screws on both sides. Ensure screws pierce external coating of pipe when tightened. (See page 55)

All Ductile Iron couplings use an M8 bolt and require a 6mm allen key. The coupling incorporates an anti-turn feature which holds the bolt nut in place without the need for a secondary tool. (See pages 37 and 59 for details of fixing tools)

66

BIM available

www.harmerdrainage.co.uk


Articles inside

Other Harmer Drainage Products

5min
pages 83-88

Below Ground Standard Clauses for Typical Installation

5min
page 82

Above Ground Standard Clauses for Typical Installation

4min
page 81

Above Ground Considerations

2min
page 71

Installation Above Ground - Ductile Iron Coupling

1min
page 66

Bracket Usage and Performance

5min
pages 61-63

Installation Above Ground - Stainless Steel Coupling

1min
page 67

Installation Below Ground - Ductile Iron Coupling

1min
page 68

Below Ground Considerations

5min
pages 72-73

Installation Below Ground - Stainless Steel Coupling

1min
page 69

Coupling Usage

2min
page 59

Inherent Fire Performance

4min
pages 56-57

Introduction

2min
page 50

Inherent Acoustic Performance

2min
pages 54-55

Fixing Tools and Touch Up Paint

1min
page 47

Pipe Fittings - Access

1min
page 44

Product Range Summary

1min
page 39

Pipe Fittings - Branches

1min
page 43

Introduction

1min
page 38

Product Range Summary

2min
page 19

Alumasc and Harmer - Introduction

2min
page 4

Harmer SML Product Range Overview

3min
pages 14-15

The Harmer SML System

2min
pages 8-9

Integrated Drainage Solutions

2min
page 10

Benefits of the Harmer SML System

1min
page 11

Benefits of Modern Cast Iron

5min
pages 12-13

Introduction

1min
page 18
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.