Iso 9606 2 nonconformities

Page 1

International standards for welder qualification "ISO 9606 series�: Non-Conformities A.Samimi Mottaghi

Abstract

but not in ASME standard. This non conformity is repeated in 1998 and 2004 versions of this standard.

ISO 9606 standards, are series of international standards for welder qualification on different materials. So, the welder who is qualified according to these standards, shall fulfill the requirements of these standards independently from the place, examiner and the type of product. But in this review we will discuss about non conformities in these international standards and their results that could cause differences in the condition of qualification according to examiner decision with refer to unclearness and mismatches in these standards. These non-conformities are about the use of shielding gasses, range of approvals, normative references and evaluation of imperfections and etc.

Introduction Figure 1: Butt welding position on pipe ISO9606-2:1994 Welder qualification standards define the qualification tests for welders. These standards must provide a set of technical rules for a systematic qualification test of welder, and enables such qualifications to be uniformly accepted independently of the type of product, location and examiner/examining body. When qualifying welders, the emphasis is placed on welder ability to manually manipulate the electrode/welding torch/welding blowpipe and thereby producing a weld of acceptable quality.

Welding positions In 1994 version of this standard we have some pictures that clear the welding positions for qualifying the welders , we have butt welding on pipe in PC position and it is written that the pipe must be fixed , the weld axis is vertical and weld is horizontal (Figure 1). The question is why the pipe must be fixed, and what if it is rotating and the weld axis is vertical and weld is horizontal, is n, t it PC position, if we have a component that is rotating on a welding positioner then what is the welding position and on the other hand, in ISO 6947 that is the WeldsWorking positions-Definitions of angles of slope and rotations there is not mentioned that in PC position the pipe must be fixed (Figure 2). The point is that the same notification is in AWS standard

Figure 2: Butt welding position on pipe ISO6947:1990

Welder approval test certificate Annex A According to ISO9606-2:1994 and 1998 the table of range of approval is empty to fill according to the standard (Figure 3). But in ISO9606-2: 2004 dashed line are added in the table of range of approval for shielding gasses and auxiliaries (figure 2).


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.
Iso 9606 2 nonconformities by Alireza Samimi Mottaghi - Issuu