BUILDINGNAMEBOARD

PROPOSED 34"WIDE TANDOOR (NSF/ANSISTD)

BTU-100,000

PROPOSED 16"WIDEFRYER (ATFS-50)

BTU-136,000

PROPOSED 17"WIDE WOK(TAWR-16) BTU-125,000

PROPOSED 36"WIDE GASCOUN. GRIDDLE (36GMSNL) BTU-30,000

1. CONTRACTORTOPROVIDESEPARATESHUTOFFVALVESFOREACHFIXTURE.

2. VACUUMBREAKERSSHALLBEPROVIDEDFORALLSUBMERGEDINLETS.

3. NEWWATERPIPINGISTOBESIZEDASPERSECTIONP107.5OFTHEBUILDINGCODE.

4. ALLNEWWATERPIPINGTOBEBRASSORTYPE"K"COPPER.

PROVIDEMINIMUM1/2"BRANCHPIPINGTOALLFIXTUREEXCEPTFLUSHVALVESWHICHARETOHAVE 1-1/4"WATERSUPPLYPIPING,ASREQUIRED.

5. ALLWATERPIPINGTOBEINSULATEDWITHCELLULARGLASSINSULATIONORAPPROVEDEQUAL.

6. ALLSOILPIPINGBELOWGRADETOBEEXTRAHEAVYCASTIRON.ALLOTHERSOILPIPINGTOBE NO-HUB

FORSIZES3"ORLARGERANDSCHEDULE40FORSMALLERSIZES.

7. PROVIDECLEANOUTSEVERY50FEETALONGTHERUNOFTHENEWDRAINLINESANDATTHEBASEOF ALLVERTICALSTACKS.

8. PROVIDESLEEVESWHEREPIPESPASSTHOUGHTCONCRETEFLOORSANDMASONRYWALLS.

9. ALLPIPINGBELOWGRADE,SOILANDWATER,TOBEPROTECTEDAGAINSTCORROSIONBYA PROTECTIVE

COALTARCOATINGOREQUAL.FERROUSPIPINGTO BEENABELCOATED.

10. THREADEDJOINTSARETOBECOATEDREGARDLESSOFTHETYPEOFSOIL.

11. TRENCHESTOBEADEQUATEWIDTHTOPERMITTHEPROPERINSTALLATIONOFTHEPIPING.

12. ALLBACKFILLINGTOBEDONEBYHANDANDSHALLBEWELLTAMPED6"LAYERS.

13. UNDERGROUNDPIPINGTOBEINSTALLEDONFIRM,STABLEBEDDING.

14. ALLPLUMBINGFIXTURESTOCOMPLYWITHLL29/89.

15. ALLFIXTURESSHALLBESELECTEDORAPPROVEDFORINSTALLATIONBYOWNER/PLUMBER

16. ALLPLUMBINGWORKSHALLBEPERFORMEDBYALICENSEDPLUMBERANDSHALLCONFORMTOALL CODEREQUIREMENTS.

17. ALLFIXTURESSHALLBEPROPERLYVENTEDANDSHALLHAVESHUT-OFFVALVESATEACHFIXTURE WITH WATERSUPPLYINCOPPERPIPES.

18. VENTILATIONORTOILETSSHALLCOMPLYWITHCODE..

19. PLUMBINGANDMATERIALSCONTROLLEDINSPECTIONSSHALLCOMPLYWITHNEWYORKBCANDPC CODE.

20. ALLSOILWASTEDANDVENTLINESINFLOOR2"ANDLARGERBASEOFALLLINESVENTSSHALL PROJECT THROUGHTHEROOFMINIMUMOF(4").

21. NYCPLUMBINGCODE70.1.10.PLASTICPIPINGANDFITTINGSSHALLNOTBEUSED.

SPECIFICATIONSFORPLUMBING(CONTINUED)

1. CONNECTIONSTOEXISTINGWORK:MAKECONNECTIONSTOEXISTINGWORK FROMANAPPROVEDSCHEDULEATAPPROPRIATETIMESOFTHEDAYTOINSUREMINIMUM INTERFERENCEWITHTHEREGULAROPERATIONOFTHEEXISTING FACILITIES.MAINTAINOPERATIONOFEXISTINGFACILITIESASREQUIREDWITH TEMPORARYCONNECTIONS.

2. SUBMISSIONOFAPROPOSALSHALLBECONSTRUEDASEVIDENCE,THATACAREFUL EXAMINATIONOFTHEPORTIONSOFTHEEXISTINGBUILDING,EQUIPMENT,ETC. WHICHAFFECTTHISWORK,ANDTHEACCESSTOSUCHSPACEHASBEENMADE, ANDTHATTHECONTRACTORISFAMILIARWITHEXISTINGCONDITIONSAND DIFFICULTIESTHATWILL AFFECTTHEEXECUTIONOFTHEWORK.CLAIMSWILL NOTBEALLOWEDFORLABOR, EQUIPMENTORMATERIALSREQUIRED BECAUSEOFDIFFICULTIESENCOUNTERED,WHICHCOULDHAVEBEENFORESEEN DURINGSUCHANEXAMINATION.

D. SUBMITTALS:

1. SHOPDRAWINGS:

a. FOUR(4)COPIESOFSHOPDRAWINGSARETOBESUBMITTED,ONE(1)OFTHESE COPIESBEINGOFTHESHOPDRAWINGS.

2. RECORDDRAWINGS:RECORDALLDEVIATIONSFROMCONTRACTDRAWINGSANDDELIVERTO OWNERMYLARTRACINGSSHOWINGWORKASACTUALLYINSTALLED.

A. PIPING: ALLPIPINGASNYCPLUMBING

3. DOMESTICWATERPIPINGSHALLBEDISINFECTEDPERNYCBUILDINGCODEPRIOR TOCONNECTIONTOTHEBUILDING'DOMESTICWATERSYSTEM.

F. VALVES:

ALLVALVESTOBEINSTALLEDASPERNYCPLUMBING.

G. CLEANOUTS:

ALLMATERIALSCODEASPERNYCPLUMBING

J. INSULATION:

1. PROVIDEFIRERETARDANTJACKETONPIPEINSULATIONASREQUIRED.

2. HWANDCWPIPING:PROVIDE1"THICKFIBERGLASSSECTIONALPIPECOVERING

3. WITHVAPORBARRIERJACKET.

4. FLAMESPREADRATINGSHALLNOTEXCEED25ANDSMOKEDEVELOPEDRATING

5. SHALLNOTBEGREATERTHAN50.

K. PAINTING:

HANGERSANDSUPPORTSANDEXPOSEDBLACKSTEELANDCASTIRONPIPINGAND STEELANDIRONWORKSHALLBEPRIMEDWITHZINCCHROMATE.

d.ALLEXPOSEDPIPING,FITTINGS,"P"TRAPS,VACUUMBREAKERSAND VALVESTOBECHROMEPLATED.

e.EXPOSEDPIPE,FITTINGS,TRAPS,ESCUTCHEONS,VALVES,VALVE HANDLESAND ACCESSORIES,ABOVEANDBELOWFIXTURES:

GENERALNOTES

1. REMOVEALLEXISTINGINACTIVEORABANDONEDWASTE,VENT,COLD ANDHOT WATERLINESWITHINCONTRACTAREA. REMOVE FIXTURESANDASSOCIATEDLINESASINDICATEDONARCHITECTURALPLANS.

2. CONNECTNEWWASTE,VENTANDHOTANDCOLDWATERSERVICESTO EXISTING BUILDINGSERVICES.FIELDVERIFYEXACTLOCATIONOFPIPING FOREXACTLOCATION OFPOINTOFCONNECTION.

3. ALLDRAWINGSAREDIAGRAMMATIC.CONTRACTORSHALLCAREFULLY EXAMINE EXISTINGCONDITIONSBEFORESTARTINGANYWORK.

4. MAKEANYNECESSARYTEMPORARYCONNECTIONSBETWEENEXISTING AND NEWWORKTOMAINTAINCONTINUOUSSERVICEOFTHEEXISTING SYSTEMS.NOSHUTDOWNSWILLBEALLOWEDWITHOUTRECEIVINGWRITTEN APPROVALFROMBUILDINGOWNER.

5. ALLNEWCONNECTIONSTOEXISTINGSERVICESSHALLBEMADEINAN APPROVEDMANNER.

6. THEEXISTINGSYSTEMSHALLBELEFTINPERFECTWORKINGORDER UPON COMPLETIONOFNEWWORK.

7. LOCATIONANDSIZESOFEXISTINGPIPINGAREAPPROXIMATELY.EXACT SIZESANDLOCATIONSOFALLEXISTINGPIPINGSHALLBEVERIFIEDONTHE JOB.

8. ALLEXISTINGPIPING,VALVES,INSULATIONETC.DAMAGEDBYNEW WORKSHALLBE REPAIREDANDREPLACEDWITHOUTEXTRACHARGETO THEOWNER.

9. BEFORESUBMITTINGPROPOSAL,BIDDERSSHALLCAREFULLYEXAMINE FIELD CONDITIONSANDCONTRACTDRAWINGOFALLTRADES. SUBMISSIONOFPROPOSALWILLBECONSTRUEDASEVIDENCETHAT REQUIREDEXAMINATIONHASBEENMADE. LATERCLAIMSFOREXTRA LABOR,EQUIPMENTORMATERIALSREQUIREDDUETODIFFICULTIES,WHICH COULDHAVEBEENFORESEEN,WILLNOTBERECOGNIZED.

SCOPEOFWORK:

PROVIDEALLREQUIREDLABOR,MATERIALS,EQUIPMENT,ANDSERVICESNECESSARYFORACOMPLETEAND SAFEINSTALLATIONOFPLUMBINGINFULLCONFORMITYWITHREQUIREMENTSOFNEWYORKCITYBUILDING CODE,ANDALLAUTHORITIESHAVINGJURISDICTION;ALLASINDICATEDONDRAWINGSAND/ORHEREINSPECIFIED FORTHESYSTEMS.

A. DESCRIPTIONOFSYSTEMS:

1. COLDWATERANDHOTWATERSUPPLYTOFIXTURESANDCONNECTIONSTOEXISTINGPIPING, CONNECTIONSTOAPPLIANCESANDOTHEREQUIPMENTREQUIRINGSAME.

1. INSULATIONONALLCWANDHWPIPING.PLUMBINGFIXTURESASINDICATEDONDRAWINGSAND HEREINAFTER SPECIFIEDBYARCHITECT.

2. CUTTINGANDROUGHPATCHINGREQUIREDFORWORK.

3. ALLREQUIREDPIPINGSUPPORTS,HANGERSANDACCESSORIES.

4. PRESSURETESTINGTHENEWPIPINGSYSTEM.

5. SHOPDRAWINGSANDRECORDDRAWINGS.

6. INSPECTIONSANDCERTIFICATES.

7.

8. ALLINSPECTIONS,APPROVALS&SIGN-OFFS.

L. CUTTINGANDPATCHING:

PROVIDEALLCUTTINGANDROUGHPATCHINGASREQUIREDFORWORK.

M. PIPINGSUPPORTS:

ASPERNYCBUILDINGCODE/PLUMBING

N. PIPEROUTING:

ASPERNYCBUILDINGCODE/PLUMBING

O. PLUMBINGFIXTURES:

1. FURNISHANDINSTALLALLPLUMBINGFIXTURESSPECIFIEDANDINDICATEDON THEPLUMBINGAND/ORARCHITECTURALDRAWINGS.FOLLOWTHEARCHITECT'S INTERIORFINISHDRAWINGSANDINSTRUCTIONSFOREXACTLOCATIONSOFFIXTURES.

FINALSELECTIONANDAPPROVALOFALLPLUMBINGFIXTURESSHALLBEBYTHE ARCHITECT.SUBMITCATALOGCUTSTOARCHITECTFORAPPROVAL.

a.FURNISHANDINSTALLALLWATERCLOSET,SINKANDLAVATORYFIXTURESUPPORTS.

b.FINALSELECTIONANDAPPROVALOFALLPLUMBINGFIXTURES,TRIMFINISHANDCOLOR SHALLBEBYTHEARCHITECT.SUBMITCATALOGCUTSTOARCHITECT FORAPPROVAL.

1.WORKMUSTCONFORMTOTHEREQUIREMENTOFTHE2022NEWYORKCITYBUILDINGCODE,FIREDEPARTMENT REGULATIONSANDALLAPPLICABLELAWS,UTILITYCOMPANYREQUIREMENTSANDTHEBESTTRADEPRACTICES ASWELLASTHEPROJECTSAFETYPLANANDPROGRAMANDCONTRACTDOCUMENT.

2.BEFORECOMMENCINGWORK,THECONTRACTORSHALLFILETHEREQUIREDCERTIFICATEOFINSURANCEWITH THEDEPARTMENTOFBUILDINGS,OBTAINALLREQUIREDPERMITSFROMALLAPPLICABLENYCAGENCIES,AND APPLYALLFEESREQUIREDBYGOVERNINGNEWYORKCITYAGENCIES.

3.THECONTRACTORSHALLVERIFYALLEXISTINGCONDITIONSINTHEFIELDPRIORTOCOMMENCINGWORK,AND SHALLREPORTANYDISCREPANCIESBETWEENDRAWINGANDFIELDCONDITIONTOTHEPROFESSIONAL ENGINEERORREGISTEREDARCHITECTANDSHALLBENOTIFIEDINWRITINGPRIORTOCOMMENCINGWORK.

4.THECONTRACTORSHALLCOORDINATEALLWORKPROCEDUREWITHREQUIREMENTSOFLOCALAUTHORITIES ANDBUILDINGMANAGEMENT.

5.ALLDEMOLITIONMACHINEOPERATORSHALLBELICENSED.

6.THECONTRACTORSHALLTAKE,ANDBERESPONSIBLEFOR,ALLMEASUREMENTSREQUIREDFORPROSPER EXECUTIONOFTHEWORK,THECONTRACTORSHALLVERIFYDIMENSIONSANDCONDITIONSATTHEWORKSITE SOTHATALLWORKS,THECONTRACTORSHALLVERIFYDIMENSIONSANDCONDITIONSATTHEWORKSITESO THATALLWORKWILLPROPERLYJOINTOTHEEXISTINGWORK,BEFORECOMMENCINGWORK,HESHALL EXAMINEALLEXISTINGWORKONWHICHHISWORKISINANYWAYDEPENDENTFORPERFECTWORKMANSHIP ACCORDINGTOTHEINTENTOFTHESESPECIFICATIONSANDSHALLREPORTTOTHEENGINEERANY CONDITIONSWHICHWILLPREVENTHIMFROMPERFORMINGHISWORKINAFIRSTCLASSMANNER.

7.THECONTRACTORSHALLASSUMEDRISKREGARDINGDAMAGEORLOSSWHETHERBYREASONOFFIRE,THEFT ORANYOTHERCASUALTYTOTHEDEMISEDPREMISESAFTERTHECONTRACTISSIGNED,NOSUCHDAMAGEOR LOSSSHALLRELIEVETHECONTRACTORFROMCONTRACTOROBLIGATIONTOCOMPLETETHEWORK

8.PRIORTOTHESTARTOFDEMOLITION:

A.ANOTICEWITHMINIMUM10DAYSINADVANCESHALLBEGIVENTOADJOININGPROPERTYOWNERWITHWORK DESCRIPTION,TIMEFRAME,SCHEDULE,ANDCONTRACTINFORMATIONOFTHEGENERALCONTRACTORAND THEDEPARTMENTOFBUILDINGS

B.A24TO48HOURSADVANCENOTICESHALLBEGIVENTODEPARTMENTOFBUILDING212-393-2550

C.A24HOURSADVANCENOTICEINWRITTENSHALLBEGIVENTOPROJECTENGINEER.

9.ASIGNATTHEHEIGHTNOMORETHAN12FEETABOVEGROUNDSHALLBEERECTED,CONTAINING A.THENAME.ADDRESSANDTELEPHONENUMBEROFTHEOWNEROFTHEPROPERTY B.THENAME,ADDRESSANDTELEPHONENUMBEROFTHEDEMOLITIONCONTRACTOR C.THEPHONENUMBERFORREPORTINGCOMPLAINTS

10.SIDEWALKSHEDSSHALLBEDESIGNEDBYLICENSEDPROFESSIONALENGINEERANDTHEDRAWINGSHALLBEAT SIDE.DRAWINGSSHELLBESUBMITTEDFORAPPROVALTOD.O.BPRIORTOCOMMENCINGDEMOLITION.

11.SIDEWALKSHEDSHALLBEINSTALLEDPRIORTOTHECOMMENCEMENTOFDEMOLITIONWORK

12.ALLPIPEANDHANGINGSCAFFOLDINGSHALLBECOVEREDBY(0.5''WIREMESH)VERTICALSAFETYNETTING.

13.LIFTINGHOISTSHALLBEAPPROVEDBYLICENSEDP.EORR.A

14.AHOTLINENUMBERSHALLBEPROVIDEDATTHESITEFORTELEPHONINGTHETHEDEPARTMENTOFBUILDING ANDTOCLOSEOFFASTREETFORSAFETYPURPOSESTHISINFORMATIONISTOBEDISPLAYEDONASIGN.

15.ASITESAFETYLOGSHALLBEKEPTATTHESITEANDTOBEAVAILABLEFORINSPECTIONATANYTIMEDURINGTHE COURSEOFCONSTRUCTIONORDEMOLITION.

16.ALLREQUIREDREGULATORYAPPROVALAND/ORPERMITSWILLBEOBTAINEDBYCONTRACTORBEFORE COMMENCINGANYWORK.

17.ALLDEMOLITIONANDREMOVALSSHALLBEPERFORMEDINACCORDANCEWITHALLAPPLICABLEFEDERAL,STATE ANDNYC2014BUILDINGCODELAWS,SECTIONSBC3306REGULATIONSANDPROJECTSPECIFICATIONS.

18.BEFORESTARTINGANYWORK,CONTRACTORSHALLEXAMEXIT,STRUCTURECONDITIONINWHICHTHEWORKIS TOBEPERFORMED,CHECKALLTHEWORKADJOININGORATUNDERLAYLOCATIONS,REPORTTOTHEARCHITECT ANYANDALLCONDITIONSWHICHMAYINTERFEREWITHOROTHERWISEAFFECTORPREVENTTHEPROPER EXECUTIONANDCOMPLETIONOFTHEWORK,DONOTSTARTTHEWORKUNTILSUCHCONDITIONSHAVEBEEN EXAMINEDANDCOURSEOFACTIONSMUTUALLYAGREEDUPON.

19.PRIORTOTHESTARTOFDEMOLITION,THECONTRACTORSHALLCALLTOTHEATTENTIONOFTHEOWNERANY DAMAGE,CRACKSORTHEIMPERFECTIONSINTHEWORKADJACENTTODEMOLITIONSAREAS.

20.BEFORESTARTINGDEMOLITIONOPERATIONS,PROVIDETHENECESSARYSAFETYPROTECTIVEDEVICEWHERE REQUIREDANDINSTRICTACCORDANCEWITHOSHARULESANDREGULATIONS.

21.BEFORESTARTINGDEMOLITIONOPERATIONS,THECONTRACTORSHALLWORKWITHOWNERLOCATEAND IDENTIFYALLUTILITYCONNECTIONS(WATER,GAS,ELECTRICITY,STEAM,ETC).ANDARRANGETODISCONNECT,OR SHUTOFF,ANDSEAL,ORCAPOFFINDICATEDUTILITIESWITHUTILITYCOMPANY.

22.ALLDEMOLISHEDMATERIALSHALLBEREMOVEDFROMPROJECTSITEONAREGULARBASISANDLEGALLY DISPOSEOFTHEMINAEPA-APPROVEDLANDFILL.DEBRISREMOVALPROCESSSHOULDBELAYOUTACCORDINGTO DEMOSCHEDULEANDCONTAINERCAPACITYANDLOCATION.

23.THECONTRACTORSHALLOBTAINANDPAYFORFEES,PERMITSANDINSPECTIONSWHENIFREQUIREDIN CONNECTIONWITHTHEDEMOLISHEDMATERIALSREMOVALANDDISPOSALOFALLDEBRIS.

24.REPAIRAND/ORREPLACEEXCITINGITEMSNOSCHEDULEDNONOTEDTOBEDEMOLISHED,ANDNOTSPECIFIEDTO BEREMOVED,BUTWHICHBECOMEDAMAGEDDURINGTHEPROGRESSOFTHEWORK,MAKEANYANDALLSUCH REPAIRS,REPLACEMENTSANDMODIFICATIONSTORESTORETHEDAMAGEITEMSTOTHEIRORIGINALCONDITIONAT THETIMEOFDAMAGE,TOTHESATISFACTIONOFANDATADDITIONALCOSTTOTHEOWNER.

25.CLEANADJ.STRUCTURESANDIMPROVEMENTSOFDUST,DIRT,ANDDEBRISCAUSEDBYDEMOLITIONOPERATIONS. RETURNADJ.AREASTOPREVIOUSCONDITIONAFTERDEMOLITIONWORKISCOMPLETE.

26.IFMATERIALSSUSPECTEDOFCONTAININGHAZARDOUSMATERIALSAREENCOUNTERED.DOMOTDISTURB IMMEDIATELYNOTIFYENGINEERANDOWNER.OWNERWILLREMOVEHAZARDOUSMATERIALUNDERASEPARATE CONTRACT.

27.LANDFILLRECORDS:INDICATERECEIPTANDACCEPTANCEOFHAZARDOUSWASTESBYALANDFILLFACILITY LICENSEDTOACCEPTHAZARDOUSWASTES.

28.STORAGEORSALEOFREMOVEDITEMSORMATERIALSONSITEITNOTPERMITTED

29.NOBEARINGPARTITIONWALLSHALLBEREMOVEDFROMANYFLOORUNTILTHEFLOOR FRAMINGSYSTEMIFTHEFLOORABOVEANDLOWERED,ALLHEADERBEAMSANDHEADERSTAIR OPENINGSANDCHIMNEYSSHALLBECAREFULLYEXAMINEDAND,WHEREREQUIRED,SHALL SHAREDFROMTHECELLARFLOORTHROUGHSUCCESSIVEFLOORS.

30.THEWORKWILLCOMPLYWITHALLAPPLICABLESECTIONOFCHAPTER33OFTHENYCBUILDING CODEANDALLOSHA1926STANDARDSFORCONSTRUCTION.

31.THESITESAFETYPLANSHALLINCLUDEASTATEMENTTHATPRIORTOPERFORMINGANYWORK ONTHEPROJECTALLWORKERSSHALLHAVESUCCESSFULLYCOMPLETED,WITHINTHEPREVIOUS FIVECALENDARYEAR,ATENHOURCOURSEAPPROVEDBYTHEUNITEDSTATESDEPARTMENTOF LABOROCCUPATIONALSAFETYANDHEALTHADMINISTRATIONINCONSTRUCTIONINDUSTRY SAFETYANDHEALTH,ORBYTHECOMMISSIONERCOVERINGSUBSTANTIALLYTHESAMEMATERIAL, SUCCESSFULCOMPLETIONOFSUCHTRAININGCOURSESHALLBEEVIDENCEDBY(A) PRESENTATIONOFABONAFIDECOURSECOMPLETIONCARD,(B)COPYOFSUCHCARD,(C)A TRAININGROSTER.ATTENDANCERECORDOROTHERDOCUMENTATIONFROMTHECERTIFIED TRAINERPENDINGTHEISSUANCEOFSUCHCARDOR(D)OTHERVALIDPROOFWHICHMAYBE APPROVEDBYTHECOMMISSIONED,SUCHEVIDENCESHALLBEREADILYAVAILABLETOTHE COMMISSIONERUPONREQUEST.

32.ASTATEMENTTHATALLWORKSEMPLOYEDONTHESITEWILLRECEIVEDSITE-SPECIFIC SAFETYORIENTATIONPROGRAM.THISPROGRAMSHALLINCLUDEREVIEWOFANYHAZARDOUS ACTIVITIESOFTHEJOBTHATARERELEVANTTOTHETASKSANDACTIVITIESTOBEPERFORMED, ALLWORKERSMUSTATTENDSUCHAPROGRAMNOLATERTHATSEVENDAYSAFTERCOMMENCING THEIREMPLOYMENT.

33.ALLBARRIERSLOCATEDINTHESTREETMUSTBEINSTALLEDASPERDOTREGULATIONSAND MANUFACTURESSPECIFICATIONS.

NOTIFICATIONS

I.FORDEMOLITIONONLYCONTACTTHECENTER24HOURSBEFORESTARTOFWORKAT(212) 227-4416

II.FOREXCAVATIONONLYCONTACTTHECENTER24HOURSBEFORESTARTWORKAT(212) 393-2550

III.TOREPORTANINCIDENTORACCIDENTINVOLVINGACRANEORDERRICK,CALL(212)393-2127.

FIREPROTECTION&DUSTCONTROLNOTE

1.CONTRACTORSHALLPROVIDEPORTABLEFIREEXTINGUISHERATLEAST2-A:20B:C RATINGONSITEDURINGDEMOLITION.

2.CONTRACTORSHALLOBTAINANAGREEMENTFROMADJACENTPROPERTYOWNERFORTHE USEOFTHEIRWATERASWATERSOURCETOCONTROLTHEDUSTDURINGDEMOLITIONOR USEEXISTINGFIREHYDRANTWITHAREQUIREDDEPPERMIT.

3.ALLMEANSOFFIREDETECTION&SUPPRESSIONSHALLBEACCORDANCEWITHDNYRULES& REGULATIONS.

4.CONTRACTORSHOULDPROVIDESUFFICIENTEATERCONTROLTHEDUSTDURING DEMOLITION,FIREHYDRANTSSHALLBITBEOPENEDTOACCOMPLISHTHEREQUIREMENT UNLESSAFIREHYDRANTUSEPERMITISINEFFECT.

5.THEEXISTINGBUILDINGSSPRINKLERSYSTEM,STANDPIPEANDSIAMESECONNECTIONS WERENOTOBSERVEDATTHETIMEOFJOBSITEVISIT.

HOTWORKSNOTES:

TRAINEDPERSONNEL(FIREWATCH)WHOAREINATTENDANCEDURINGTHEENTIREHOTWORK OPERATIONANDAREIMMEDIATELYAVAILABLETOEXTINGUISHAFIREORTAKEOTHEREFFECTIVE ACTIONIFNEEDED

SAFETYPROTECTION:

ANYONEWORKINGWITHINCONSTRUCTIONSAFETYZONEHASTOFOLLOWTHEOSAH CONSTRUCTIONSAFETYPROTECTIONREQUIREMENT.EVERYONEMUSTBEWEAR-HEAD,STEEL TOEBOOTS,RESPIRATOR,SAFETY-GLASS.IFANYONEWORKINGONTHEPLATFORMIS6FEET ABOVEGROUNDORFLOORMUSTWEARBELTORHARNESS

CELLARFLOORDEMOLITIONPLAN

PROPERTYLINE

DEMOLITIONNOTES:

1.THECONTRACTORMUSTOBTAINALLAPPLICABLEPERMITSANDPERMISSIONFROMNYC DOBANDNYCDOTPRIORTOCRANEUSEONSITE.GENERALCONTRACTORSHALLFILE CRANEPERMITUNDERSEPARATEDAPPLICATION,SEEFD-101FORPERMITAPPLICATION LISTTABLE.

2.ASBESTOSABATEMENTCERTIFICATE(WHENREQUIRED)SHOULDBEAVAILABLEATTHE TIMEOFAPPLYINGFORDEMOLITIONPERMITS.

3.NOPERSONNELISPERMITTEDONTHEDEMOLITIONSITEDURINGUSINGMECHANICAL EQUIPMENTEXCEPTOPERATORANDAUTHORIZEDPERSONNEL.

4.NOPERSONNELISPERMITTEDATTHEUNDERSIDEDURINGOPERATIONOFCRANE.

5.CONTRACTORSHALLOBTAINPERMITFORSIDEWALKSHED,OVERHEADPROTECTION SHED,SCAFFOLDING,ANDCONSTRUCTIONFENCEUNDERSEPARATEAPPLICATION.

6.CONTRACTORISRESPONSIBLEFOROBTAINANAGREEMENTFROMADJ.PROPERTY OWNERTOINSTALLSAFETYNETTING,FIRERETARDANTROOFPROTECTION, CONSTRUCTIONFENCE,OVERHEADPROTECTIONSHEDANDPLYWOODPROTECTION WITHINTHEIRPROPERTY.

7.CONTRACTORSHOULDPROVIDEATLEASTONEQUALIFIEDWATCHPERSONATTHESITE DURINGDEMOLITION.AQUALIFIEDWATCHPERSONSHALLBEFAMILIARWITHEMERGENCY NOTIFICATIONPROCEDURESTOTHEFDNY,SHALLPASSESAVALIDSECURITYGUARD CERTIFICATEFROMTHESTATEOFNEWYORKSHALLHOLDAVALIDFIREGUARD CERTIFICATEFROMFDNY.

ADJ.12''INDEPENDENT BRICKWALL (NOWORK)

2STORY+CELLAR FRAMEBUILDING HEIGHT:24'8"

135WOODBINEST BL:3350LT:43

OBTAINADJPROPERTYOWNER CONSENTTOINSTALL SCAFFOLDING

CONTROLLED ACCESSZONE TEMPORARY FENCING

ADJ.12''INDEPENDENT BRICKWALL (NOWORK)

ADJ.12''INDEPENDENT BRICKWALL (NOWORK)

2STYFRAMEBLDG HEIGHT:27'0"

INFOSIGN INSTALLOVERHEAD PROTECTIONSHED(TYP.) HT:12'-0''

SIDEWALK FOR PEDESTRIAN

WOODBINESTREET

CONCRETESIDEWALK

8.CONTRACTORSHALLUSESEXTRACAUTIONWHENWORKINGWITHINORCLOSELYTOADJ. PROPERTY.ALLDEBRISMUSTBEPULLEDINSIDEANDSLOWLYLOWEREDBYCHUTE.

9.CONTRACTORSHOULDPROVIDESUFFICIENTWATERTOCONTROLTHEDUSTDURING DEMOLITION.USEOFAHYDRANTREQUIRESADEPPERMITANDTHISPERMITSHALLBE KEPTONSITEATALLTIMES.

PREPARATIONSTAGEANDDEMOLITIONOPERATIONNOTES:

1.INSTALLSCAFFOLDINGS,DEBRISCHUTE,CONSTRUCTIONFENCE,CONTROLLED ACCESSZONEANDTEMP.BRACINGOREXTERIORWALLSASINDICATEDFROMFD-101 THROUGHFD-104.

2.REMOVEEXIST.GLASSINTHEDOORS,WINDOWS,ANDFIXTURESBEFORESTARTOF DEMOLITIONPERBC3306.9.8.

3.REMOVEEXIST.CONCRETESTEPSBEFORETHESTARTOFDEMOLITION.

4.REMOVEEXIST.ELEVATORCARTANDASSEMBLYBEFORETHESTARTOF DEMOLITION.

5.SIDEWALKSSHALLBECLEAREDOFDEBRISORCONSTRUCTIONMATERIALSATALL TIME.

6.ALLMECHANICALDEMOLITIONSHALLBEPERFORMEDBYSKILLEDLICENSED MECHANICS.

7.THECONTRACTORSHALLASSUMEDRISKREGARDINGDAMAGEORLOSSWHETHERBY REASONOFFIRE,THEFTORANYOTHERCASUALTYTOTHEDEMISEDPREMISES AFTERTHECONTRACTISSIGNED,NOSUCHDAMAGEORLOSSSHALLRELIEVETHE CONTRACTORFROMCONTRACTOBLIGATIONTOCOMPLETETHEWORK.

8.THECONTRACTORSHALLDISPOSEOFALLDEMISEDMATERIALSINCLUDINGCARTING AWAYDEMOLISHEDMATERIALSFROMTHESITEINAMANNERAPPROVEDBYTHE BUILDINMANAGEMENTANDGOVERNMENTREGULATIONIMMEDIATELYAFTER DEMOLITIONUNLESSOTHERWISEINSTRUCTED.

9.EXCAVATORANDOTHERHEAVYMECHANICALEQUIPMENTSHALLBELOCATEDNOT LESSTHAN1.5TIMESDEPTHOFDEMOFOOTINGFROMEDGEOFTHEEXCAVATION BUILDINGORSTRUCTURES.

10.PROVIDESAFETYFLAGMANFOREACHADJACENTPROPERTYSIDE/REARYARDTO MAKESURENOBODYWILLWALKTHROUGHTHATAREA.

11.ALLDIMENSIONANDELEVATIONINDICATEDWITHINPLANSHALLBEVERIFIEDINFIELD BYCONTRACTOR.

SEPARATEAPPLICATION

EXIST.2STORYFRAME TOBEREMOVEDINA SEPARATEAPPLICATION

PROPERTYLINE

ADJ.12''INDEPENDENT BRICKWALL (NOWORK)

PREPARATION:

STAGE1:

INSTALLCONSTRUCTIONFENCEREMOVEMETALDOOR,WINDOWSANDANYOTHERACCESSORY STRUCTURE,SUCHASREMOVABLECONTAINER,METALCAGING,FRAMESHED,RAISEDCONCRETEINSTALL SCAFFOLDING,SIDEWALKSHED,CHUTEANDTEMPORARYWALLBRACING(8'TYP.)ASINDICATEDONFD-101 THROUGHDEMOLITIONPLANONFD-204,ADJACENTENTRANCESHALLNOTBEBLOCKED,SCAFFOLDING SHALLBEINSTALLEDWITHDOUBLELAYERVERTICALDEBRISNETTINGANDATLEAST3'-6"HIGHERABOVE ROOF.

DEMOLITIONSEQUENCE:

STAGE1:

STARTHANDDEMOLITIONOFROOFING,REMOVEROOFMEMBRANES,INSULATIONLAYERS,ANDPLYWOOD, EXPOSEALLSTRUCTURALMEMBERSTHATSUPPORTTHEROOF.

STAGE2:

STARTHANDDEMOLITIONOFWOODJOISTONROOFFLOOR.WORKEROPERATEFROMAROLLING SCAFFOLDINGCUTTINGJOISTINTOSMALLPIECESANDTHENCAREFULLYLOWERINGTOLOWERFLOOR. EACHPIECESHALLLIMITEDTO10FEETINLENGTH.NODEBRISACCUMULATIONONFLOORISPERMITTED.

STAGE3:

DISCONNECTALLPLUMBINGLINESANDREMOVEALLTHEEXISTINGPLUMBINGFIXTURESFROMTHE TOILETONTHE2NDFLOOR.

STAGE4:

SAFETYHANDDEMOLITIONFORTHEINTERIORANDEXTERIORWALLSON2NDFLOOR. THEWALLSHALLBEDEMOLISHEDLAYERBYLAYERACCORDINGTODETAILANDPROCEDUREASSHOWNIN DETAIL"4"ONFD-106.EACHLAYERSLIMITEDTO1'HEIGHTOR2BLOCKS,WHICHEVERISSMALLER.THE SEQUENCEOFDEMOLITIONISINSUCHAWAYTHATTHEINTERNALWALLSWILLBEDEMOLISHEDFIRST FOLLOWEDBYTHEEXTERIORFRAMEWALLS

EGRESSNOTES:

1.DURINGDEMOLITION,THEMEANSOFEGRESSAND EXIST.STAIRSSHALLNOTBEBLOCKEDBYEQUIPMENT, DEBRISANDMATERIAL.THESTAIRSHALLBELIGHTED ATALLTIME.

DEBRISREMOVALNOTES:

1.ALLDEBRISSHALLNOTBETHROWNORDROPPEDFROM THEBUILDING,MUSTBEDISMANTLEDPIECEBYPIECE, CHAINED,LASHEDANDCAREFULLYLOWERBYCHUTE.

2.ALLDEBRISMUSTBECLEANEDOUTFROMTHE WORKINGAREABEFOREPROCEEDINGTONEXTSTAGE. NODEBRISACCUMULATIONONFLOORISPERMITTED. 3.ALLDEBRISSHALLBECLEANEDOFFFLOORSDAILY.

INTERIORWALLS

THEREMOVALOFTHEINTERIORWALLSHASBEEN COORDINATEDWITHTHELOADCAPACITYOFTHE EXTERIORWALLSANDFLOORS.

TEMPORARY FENCING

CONTROLLED ACCESSZONE

ADJ.12''INDEPENDENT BRICKWALL (NOWORK)

ADJ.12''INDEPENDENT BRICKWALL (NOWORK) 2STYFRAMEBLDG HEIGHT:27'0"

DRIVEWAY

PROPERTYLINE

TEMPORARY FENCING

CONTROLLED ACCESSZONE

ADJ.12''INDEPENDENT BRICKWALL (NOWORK)

DEMOLITIONSEQUENCE:

STAGE5: DISCONNECTALLPLUMBINGANDGASLINESANDREMOVEALLTHEEXISTINGPLUMBINGANDGAS OPERATEDFIXTURESFROMTHEKITCHENANDTOILETONTHE1STFLOOR.

STAGE6:

STARTHANDDEMOLITIONOFTHEPORCHROOFAND2NDFLOORDECK,REMOVEFLOORMEMBRANES, INSULATIONLAYERS,ANDPLYWOOD,EXPOSEALLSTRUCTURALMEMBERSTHATSUPPORTTHEFLOOR.

STAGE7:

STARTHANDDEMOLITIONOFWOODJOISTON2NDFLOORDECKANDPORCHROOF.WORKEROPERATE FROMAROLLINGSCAFFOLDINGCUTTINGJOISTINTOSMALLPIECESANDTHENCAREFULLYLOWERINGTO LOWERFLOOR.EACHPIECESHALLLIMITEDTO10FEETINLENGTH.NODEBRISACCUMULATIONONFLOOR ISPERMITTED.

STAGE8:

STARTHANDDEMOLITIONOFSTAIRCASEGOINGTOTHE2NDFLOOR.

STAGE9:

SAFETYHANDDEMOLITIONFORTHEINTERIORANDEXTERIORWALLSON1STFLOOR. THEWALLSHALLBEDEMOLISHEDLAYERBYLAYERACCORDINGTODETAILANDPROCEDUREASSHOWNIN DETAIL"4"ONFD-106.EACHLAYERSLIMITEDTO1'HEIGHTOR2BLOCKS,WHICHEVERISSMALLER.THE SEQUENCEOFDEMOLITIONISINSUCHAWAYTHATTHEINTERNALWALLSWILLBEDEMOLISHEDFIRST FOLLOWEDBYTHEEXTERIORFRAMEWALLS

EGRESSNOTES:

ADJ.12''INDEPENDENT BRICKWALL

1.DURINGDEMOLITION,THEMEANSOFEGRESSAND EXIST.STAIRSSHALLNOTBEBLOCKEDBYEQUIPMENT, DEBRISANDMATERIAL.THESTAIRSHALLBELIGHTED ATALLTIME.

DEBRISREMOVALNOTES:

1.ALLDEBRISSHALLNOTBETHROWNORDROPPEDFROM THEBUILDING,MUSTBEDISMANTLEDPIECEBYPIECE, CHAINED,LASHEDANDCAREFULLYLOWERBYCHUTE. 2.ALLDEBRISMUSTBECLEANEDOUTFROMTHE WORKINGAREABEFOREPROCEEDINGTONEXTSTAGE. NODEBRISACCUMULATIONONFLOORISPERMITTED. 3.ALLDEBRISSHALLBECLEANEDOFFFLOORSDAILY.

INTERIORWALLS

COORDINATEDWITHTHELOADCAPACITYOFTHE EXTERIORWALLSANDFLOORS.

BEREMOVEDINA SEPARATEAPPLICATION

EXIST.2STORYFRAME TOBEREMOVEDINA SEPARATEAPPLICATION

PROPERTYLINE

EGRESSNOTES:

DEMOLITIONSEQUENCE:

STAGE10:

DISCONNECTALLPLUMBING,ELECTRICALANDGASLINES,REMOVEALLTHEEXISTINGBATHROOM FIXTURES,HOTWATERTANKANDBOILERFROMTHECELLARFLOOR,ELECTRICANDGASMETERS.

STAGE11:

STARTHANDDEMOLITIONOFTHE1STFLOORDECK,REMOVEFLOORMEMBRANES,INSULATIONLAYERS, ANDPLYWOOD,EXPOSEALLSTRUCTURALMEMBERSTHATSUPPORTTHEFLOOR.

STAGE12:

STARTHANDDEMOLITIONOFWOODJOISTOF1STFLOORDECK.

STAGE13:

STARTHANDDEMOLITIONOFBRICKSTAIRON1STFLOORMAINENTRANCEANDDEMOLISHTHEPORCH.

STAGE14:

SAFETYHANDDEMOLITIONFORTHEINTERIORWALLSONCELLARFLOOR.THEWALLSHALLBE DEMOLISHEDLAYERBYLAYERACCORDINGTODETAILANDPROCEDUREASSHOWNINDETAIL"4"ON FD-106.EACHLAYERSLIMITEDTO1'HEIGHTOR2BLOCKS,WHICHEVERISSMALLER.THESEQUENCEOF DEMOLITIONISINSUCHAWAYTHATTHEINTERNALWALLSWILLBEDEMOLISHEDFIRSTFOLLOWEDBYTHE PARTIALEXTERIORFRAMEWALLS

STAGE15: STARTHANDDEMOLITIONOFSTAIRCASEGOINGFROMTHECELLARUPTOTHE1STFLOOR.

ADJ.12''INDEPENDENT BRICKWALL

1STFLOORDECK MEMBRANE& WOODENJOISTS TOBEREMOVED

TEMPORARY FENCING

CONTROLLED ACCESSZONE

ADJ.12''INDEPENDENT BRICKWALL (NOWORK)

ADJ.12''INDEPENDENT BRICKWALL (NOWORK) 2STYFRAMEBLDG HEIGHT:27'0"

1.DURINGDEMOLITION,THEMEANSOFEGRESSAND EXIST.STAIRSSHALLNOTBEBLOCKEDBYEQUIPMENT, DEBRISANDMATERIAL.THESTAIRSHALLBELIGHTED ATALLTIME.

DEBRISREMOVALNOTES:

1.ALLDEBRISSHALLNOTBETHROWNORDROPPEDFROM THEBUILDING,MUSTBEDISMANTLEDPIECEBYPIECE, CHAINED,LASHEDANDCAREFULLYLOWERBYCHUTE.

2.ALLDEBRISMUSTBECLEANEDOUTFROMTHE WORKINGAREABEFOREPROCEEDINGTONEXTSTAGE. NODEBRISACCUMULATIONONFLOORISPERMITTED.

3.ALLDEBRISSHALLBECLEANEDOFFFLOORSDAILY.

ADJ.12''INDEPENDENT

EXIST.FRAMEGARAGETO BEREMOVEDINA SEPARATEAPPLICATION

EXIST.2STORYFRAME TOBEREMOVEDINA SEPARATEAPPLICATION

DEMOLITIONSEQUENCE:

STAGE16: APPLYWEATHERPROOFINGFORNEWLYEXPOSUREWALLOFADJ.BUILDING,SEEDETAIL'5'ONFD-106.

STAGE17:

STARTHANDDEMOLITIONOFSLABONGRADEANDCONCRETEFOUNDATIONWALL/FOOTINGOF BUILDING.THEFOUNDATIONWALLANDFOOTINGSHALLBEDEMOLISHEDSECTIONBYSECTIONANDNOT EXCEED6'MAX.SPACE.SEEDETAIL'5'ONFD-106.ONCEEACHSECTIONREMOVED,BACKFILLTHESECTION IMMEDIATELYWITHCLEANSOILMATERIAL.

STAGE18: ONCELASTSTAGEFINISHED,BACKFILLIMMEDIATELYWITHCLEANSOILMATERIALTOGROUNDLEVEL.

MAINTAINADJACENTPROPERTY'SSTRUCTURALSTABILITY.REQUESTTOLEAVEPARTIALFOUNDATION WALLANDFOOTINGWITHIN4FEETALONGTHEEACHSIDEOFDEMOLITIONSITEASINDICTEDONFD-103 THROUGHFD-104.

CONSTRUCTIONFENCENOTES:

THECONSTRUCTIONFENCEWILLBERELOCATEDTOPROPERTYLINE.AFTERCOMPLETIONOFDEMOLITION ALLBUILDINGENCLOSEDBYTHESAMECONSTRUCTIONFENCE.

EGRESSNOTES:

1.DURINGDEMOLITION,THEMEANSOFEGRESSAND EXIST.STAIRSSHALLNOTBEBLOCKEDBYEQUIPMENT, DEBRISANDMATERIAL.THESTAIRSHALLBELIGHTED ATALLTIME.

DEBRISREMOVALNOTES:

1.ALLDEBRISSHALLNOTBETHROWNORDROPPEDFROM THEBUILDING,MUSTBEDISMANTLEDPIECEBYPIECE, CHAINED,LASHEDANDCAREFULLYLOWERBYCHUTE.

2.ALLDEBRISMUSTBECLEANEDOUTFROMTHE WORKINGAREABEFOREPROCEEDINGTONEXTSTAGE. NODEBRISACCUMULATIONONFLOORISPERMITTED.

3.ALLDEBRISSHALLBECLEANEDOFFFLOORSDAILY.

INTERIORWALLS

THEREMOVALOFTHEINTERIORWALLSHASBEEN

NOTE:WIDTHMAYBEREDUCEDTO5'ON NARROWSIDEWALKSASREQUIREDTO MAINTAINSIDEWALKCLEARANCEOF3' (THREEFEET)ATTHETREEBARRIERSONLY.

4''X4''POSTS,TYPICAL

2''X8''PLANKS ALLAROUND

5'-0'' 5'-0''

SECTIONA-A

DETAILS-PROTECTIONTREEBARRIER

SNOWFENCETYPETREEWRAP

2''X8''PLANKS,ALLAROUND

4''X4''POSTS,TYPICAL

2''X8''BRACES,ALLAROUND 2''X8''PLANKS,ALLAROUND 10'' 4' TYPE A 6' TYPE B

1TYP.TREEPROTECTIONDETAIL

SCALE:N.T.S ADJ.PROPERTY

1.PATCHALLHOLESORCRACKS,AND MAKESURFACECLEANANDFREE FROMDIRT,DUSTGREASEOIL,ETC 2.APPLYPARGECOATANDASCERTAIN THECOATINGISINSOUND CONDITION.

3.APPLYLATEXBASEDRYLOK MASONRYWATERPROOFERTOADJ. PROPERTYEXPOSEDWALL.

4.AFTER3HOUR,APPLYTHESECOND COATINGOFWATERPROOFING.

RECOMMENDEDFILMTHICKNESS/COAT: 13-21WETMILS/COAT

2TYP.WEATHERDETAIL

SCALE:N.T.S

TYP.HANDDEMOCMU/BRICKWALLDETAILANDPROCEDURE4SCALE:N.T.S NOTE: WALLSSHALLBEHANDDEMOLAYERBYLAYER,EACHLAYERIS

FASTENTEMP.WALLBRACINGTOEXIST.WOOD STUDW/10X3WOODSCREW@12''O.C.(TYP.) 2X6TIMBER(TYP.)

2X6TIMBER(TYP.)

2X4TIMBERSTIFFENERCONNECTED TODIAGONALSUPPORTWITHSCREW (ONBOTHSIDES)

2X6TIMBER(TYP.)