BUILDINGNAMEBOARD
PROPOSED 34"WIDE TANDOOR (NSF/ANSISTD)
BTU-100,000
PROPOSED 16"WIDEFRYER (ATFS-50)
BTU-136,000
PROPOSED 17"WIDE WOK(TAWR-16) BTU-125,000
PROPOSED 36"WIDE GASCOUN. GRIDDLE (36GMSNL) BTU-30,000
1. CONTRACTORTOPROVIDESEPARATESHUTOFFVALVESFOREACHFIXTURE.
2. VACUUMBREAKERSSHALLBEPROVIDEDFORALLSUBMERGEDINLETS.
3. NEWWATERPIPINGISTOBESIZEDASPERSECTIONP107.5OFTHEBUILDINGCODE.
4. ALLNEWWATERPIPINGTOBEBRASSORTYPE"K"COPPER.
PROVIDEMINIMUM1/2"BRANCHPIPINGTOALLFIXTUREEXCEPTFLUSHVALVESWHICHARETOHAVE 1-1/4"WATERSUPPLYPIPING,ASREQUIRED.
5. ALLWATERPIPINGTOBEINSULATEDWITHCELLULARGLASSINSULATIONORAPPROVEDEQUAL.
6. ALLSOILPIPINGBELOWGRADETOBEEXTRAHEAVYCASTIRON.ALLOTHERSOILPIPINGTOBE NO-HUB
FORSIZES3"ORLARGERANDSCHEDULE40FORSMALLERSIZES.
7. PROVIDECLEANOUTSEVERY50FEETALONGTHERUNOFTHENEWDRAINLINESANDATTHEBASEOF ALLVERTICALSTACKS.
8. PROVIDESLEEVESWHEREPIPESPASSTHOUGHTCONCRETEFLOORSANDMASONRYWALLS.
9. ALLPIPINGBELOWGRADE,SOILANDWATER,TOBEPROTECTEDAGAINSTCORROSIONBYA PROTECTIVE
COALTARCOATINGOREQUAL.FERROUSPIPINGTO BEENABELCOATED.
10. THREADEDJOINTSARETOBECOATEDREGARDLESSOFTHETYPEOFSOIL.
11. TRENCHESTOBEADEQUATEWIDTHTOPERMITTHEPROPERINSTALLATIONOFTHEPIPING.
12. ALLBACKFILLINGTOBEDONEBYHANDANDSHALLBEWELLTAMPED6"LAYERS.
13. UNDERGROUNDPIPINGTOBEINSTALLEDONFIRM,STABLEBEDDING.
14. ALLPLUMBINGFIXTURESTOCOMPLYWITHLL29/89.
15. ALLFIXTURESSHALLBESELECTEDORAPPROVEDFORINSTALLATIONBYOWNER/PLUMBER
16. ALLPLUMBINGWORKSHALLBEPERFORMEDBYALICENSEDPLUMBERANDSHALLCONFORMTOALL CODEREQUIREMENTS.
17. ALLFIXTURESSHALLBEPROPERLYVENTEDANDSHALLHAVESHUT-OFFVALVESATEACHFIXTURE WITH WATERSUPPLYINCOPPERPIPES.
18. VENTILATIONORTOILETSSHALLCOMPLYWITHCODE..
19. PLUMBINGANDMATERIALSCONTROLLEDINSPECTIONSSHALLCOMPLYWITHNEWYORKBCANDPC CODE.
20. ALLSOILWASTEDANDVENTLINESINFLOOR2"ANDLARGERBASEOFALLLINESVENTSSHALL PROJECT THROUGHTHEROOFMINIMUMOF(4").
21. NYCPLUMBINGCODE70.1.10.PLASTICPIPINGANDFITTINGSSHALLNOTBEUSED.
SPECIFICATIONSFORPLUMBING(CONTINUED)
1. CONNECTIONSTOEXISTINGWORK:MAKECONNECTIONSTOEXISTINGWORK FROMANAPPROVEDSCHEDULEATAPPROPRIATETIMESOFTHEDAYTOINSUREMINIMUM INTERFERENCEWITHTHEREGULAROPERATIONOFTHEEXISTING FACILITIES.MAINTAINOPERATIONOFEXISTINGFACILITIESASREQUIREDWITH TEMPORARYCONNECTIONS.
2. SUBMISSIONOFAPROPOSALSHALLBECONSTRUEDASEVIDENCE,THATACAREFUL EXAMINATIONOFTHEPORTIONSOFTHEEXISTINGBUILDING,EQUIPMENT,ETC. WHICHAFFECTTHISWORK,ANDTHEACCESSTOSUCHSPACEHASBEENMADE, ANDTHATTHECONTRACTORISFAMILIARWITHEXISTINGCONDITIONSAND DIFFICULTIESTHATWILL AFFECTTHEEXECUTIONOFTHEWORK.CLAIMSWILL NOTBEALLOWEDFORLABOR, EQUIPMENTORMATERIALSREQUIRED BECAUSEOFDIFFICULTIESENCOUNTERED,WHICHCOULDHAVEBEENFORESEEN DURINGSUCHANEXAMINATION.
D. SUBMITTALS:
1. SHOPDRAWINGS:
a. FOUR(4)COPIESOFSHOPDRAWINGSARETOBESUBMITTED,ONE(1)OFTHESE COPIESBEINGOFTHESHOPDRAWINGS.
2. RECORDDRAWINGS:RECORDALLDEVIATIONSFROMCONTRACTDRAWINGSANDDELIVERTO OWNERMYLARTRACINGSSHOWINGWORKASACTUALLYINSTALLED.
A. PIPING: ALLPIPINGASNYCPLUMBING
3. DOMESTICWATERPIPINGSHALLBEDISINFECTEDPERNYCBUILDINGCODEPRIOR TOCONNECTIONTOTHEBUILDING'DOMESTICWATERSYSTEM.
F. VALVES:
ALLVALVESTOBEINSTALLEDASPERNYCPLUMBING.
G. CLEANOUTS:
ALLMATERIALSCODEASPERNYCPLUMBING
J. INSULATION:
1. PROVIDEFIRERETARDANTJACKETONPIPEINSULATIONASREQUIRED.
2. HWANDCWPIPING:PROVIDE1"THICKFIBERGLASSSECTIONALPIPECOVERING
3. WITHVAPORBARRIERJACKET.
4. FLAMESPREADRATINGSHALLNOTEXCEED25ANDSMOKEDEVELOPEDRATING
5. SHALLNOTBEGREATERTHAN50.
K. PAINTING:
HANGERSANDSUPPORTSANDEXPOSEDBLACKSTEELANDCASTIRONPIPINGAND STEELANDIRONWORKSHALLBEPRIMEDWITHZINCCHROMATE.
d.ALLEXPOSEDPIPING,FITTINGS,"P"TRAPS,VACUUMBREAKERSAND VALVESTOBECHROMEPLATED.
e.EXPOSEDPIPE,FITTINGS,TRAPS,ESCUTCHEONS,VALVES,VALVE HANDLESAND ACCESSORIES,ABOVEANDBELOWFIXTURES:
GENERALNOTES
1. REMOVEALLEXISTINGINACTIVEORABANDONEDWASTE,VENT,COLD ANDHOT WATERLINESWITHINCONTRACTAREA. REMOVE FIXTURESANDASSOCIATEDLINESASINDICATEDONARCHITECTURALPLANS.
2. CONNECTNEWWASTE,VENTANDHOTANDCOLDWATERSERVICESTO EXISTING BUILDINGSERVICES.FIELDVERIFYEXACTLOCATIONOFPIPING FOREXACTLOCATION OFPOINTOFCONNECTION.
3. ALLDRAWINGSAREDIAGRAMMATIC.CONTRACTORSHALLCAREFULLY EXAMINE EXISTINGCONDITIONSBEFORESTARTINGANYWORK.
4. MAKEANYNECESSARYTEMPORARYCONNECTIONSBETWEENEXISTING AND NEWWORKTOMAINTAINCONTINUOUSSERVICEOFTHEEXISTING SYSTEMS.NOSHUTDOWNSWILLBEALLOWEDWITHOUTRECEIVINGWRITTEN APPROVALFROMBUILDINGOWNER.
5. ALLNEWCONNECTIONSTOEXISTINGSERVICESSHALLBEMADEINAN APPROVEDMANNER.
6. THEEXISTINGSYSTEMSHALLBELEFTINPERFECTWORKINGORDER UPON COMPLETIONOFNEWWORK.
7. LOCATIONANDSIZESOFEXISTINGPIPINGAREAPPROXIMATELY.EXACT SIZESANDLOCATIONSOFALLEXISTINGPIPINGSHALLBEVERIFIEDONTHE JOB.
8. ALLEXISTINGPIPING,VALVES,INSULATIONETC.DAMAGEDBYNEW WORKSHALLBE REPAIREDANDREPLACEDWITHOUTEXTRACHARGETO THEOWNER.
9. BEFORESUBMITTINGPROPOSAL,BIDDERSSHALLCAREFULLYEXAMINE FIELD CONDITIONSANDCONTRACTDRAWINGOFALLTRADES. SUBMISSIONOFPROPOSALWILLBECONSTRUEDASEVIDENCETHAT REQUIREDEXAMINATIONHASBEENMADE. LATERCLAIMSFOREXTRA LABOR,EQUIPMENTORMATERIALSREQUIREDDUETODIFFICULTIES,WHICH COULDHAVEBEENFORESEEN,WILLNOTBERECOGNIZED.
SCOPEOFWORK:
PROVIDEALLREQUIREDLABOR,MATERIALS,EQUIPMENT,ANDSERVICESNECESSARYFORACOMPLETEAND SAFEINSTALLATIONOFPLUMBINGINFULLCONFORMITYWITHREQUIREMENTSOFNEWYORKCITYBUILDING CODE,ANDALLAUTHORITIESHAVINGJURISDICTION;ALLASINDICATEDONDRAWINGSAND/ORHEREINSPECIFIED FORTHESYSTEMS.
A. DESCRIPTIONOFSYSTEMS:
1. COLDWATERANDHOTWATERSUPPLYTOFIXTURESANDCONNECTIONSTOEXISTINGPIPING, CONNECTIONSTOAPPLIANCESANDOTHEREQUIPMENTREQUIRINGSAME.
1. INSULATIONONALLCWANDHWPIPING.PLUMBINGFIXTURESASINDICATEDONDRAWINGSAND HEREINAFTER SPECIFIEDBYARCHITECT.
2. CUTTINGANDROUGHPATCHINGREQUIREDFORWORK.
3. ALLREQUIREDPIPINGSUPPORTS,HANGERSANDACCESSORIES.
4. PRESSURETESTINGTHENEWPIPINGSYSTEM.
5. SHOPDRAWINGSANDRECORDDRAWINGS.
6. INSPECTIONSANDCERTIFICATES.
7.
8. ALLINSPECTIONS,APPROVALS&SIGN-OFFS.
L. CUTTINGANDPATCHING:
PROVIDEALLCUTTINGANDROUGHPATCHINGASREQUIREDFORWORK.
M. PIPINGSUPPORTS:
ASPERNYCBUILDINGCODE/PLUMBING
N. PIPEROUTING:
ASPERNYCBUILDINGCODE/PLUMBING
O. PLUMBINGFIXTURES:
1. FURNISHANDINSTALLALLPLUMBINGFIXTURESSPECIFIEDANDINDICATEDON THEPLUMBINGAND/ORARCHITECTURALDRAWINGS.FOLLOWTHEARCHITECT'S INTERIORFINISHDRAWINGSANDINSTRUCTIONSFOREXACTLOCATIONSOFFIXTURES.
FINALSELECTIONANDAPPROVALOFALLPLUMBINGFIXTURESSHALLBEBYTHE ARCHITECT.SUBMITCATALOGCUTSTOARCHITECTFORAPPROVAL.
a.FURNISHANDINSTALLALLWATERCLOSET,SINKANDLAVATORYFIXTURESUPPORTS.
b.FINALSELECTIONANDAPPROVALOFALLPLUMBINGFIXTURES,TRIMFINISHANDCOLOR SHALLBEBYTHEARCHITECT.SUBMITCATALOGCUTSTOARCHITECT FORAPPROVAL.




1.WORKMUSTCONFORMTOTHEREQUIREMENTOFTHE2022NEWYORKCITYBUILDINGCODE,FIREDEPARTMENT REGULATIONSANDALLAPPLICABLELAWS,UTILITYCOMPANYREQUIREMENTSANDTHEBESTTRADEPRACTICES ASWELLASTHEPROJECTSAFETYPLANANDPROGRAMANDCONTRACTDOCUMENT.
2.BEFORECOMMENCINGWORK,THECONTRACTORSHALLFILETHEREQUIREDCERTIFICATEOFINSURANCEWITH THEDEPARTMENTOFBUILDINGS,OBTAINALLREQUIREDPERMITSFROMALLAPPLICABLENYCAGENCIES,AND APPLYALLFEESREQUIREDBYGOVERNINGNEWYORKCITYAGENCIES.
3.THECONTRACTORSHALLVERIFYALLEXISTINGCONDITIONSINTHEFIELDPRIORTOCOMMENCINGWORK,AND SHALLREPORTANYDISCREPANCIESBETWEENDRAWINGANDFIELDCONDITIONTOTHEPROFESSIONAL ENGINEERORREGISTEREDARCHITECTANDSHALLBENOTIFIEDINWRITINGPRIORTOCOMMENCINGWORK.
4.THECONTRACTORSHALLCOORDINATEALLWORKPROCEDUREWITHREQUIREMENTSOFLOCALAUTHORITIES ANDBUILDINGMANAGEMENT.
5.ALLDEMOLITIONMACHINEOPERATORSHALLBELICENSED.
6.THECONTRACTORSHALLTAKE,ANDBERESPONSIBLEFOR,ALLMEASUREMENTSREQUIREDFORPROSPER EXECUTIONOFTHEWORK,THECONTRACTORSHALLVERIFYDIMENSIONSANDCONDITIONSATTHEWORKSITE SOTHATALLWORKS,THECONTRACTORSHALLVERIFYDIMENSIONSANDCONDITIONSATTHEWORKSITESO THATALLWORKWILLPROPERLYJOINTOTHEEXISTINGWORK,BEFORECOMMENCINGWORK,HESHALL EXAMINEALLEXISTINGWORKONWHICHHISWORKISINANYWAYDEPENDENTFORPERFECTWORKMANSHIP ACCORDINGTOTHEINTENTOFTHESESPECIFICATIONSANDSHALLREPORTTOTHEENGINEERANY CONDITIONSWHICHWILLPREVENTHIMFROMPERFORMINGHISWORKINAFIRSTCLASSMANNER.
7.THECONTRACTORSHALLASSUMEDRISKREGARDINGDAMAGEORLOSSWHETHERBYREASONOFFIRE,THEFT ORANYOTHERCASUALTYTOTHEDEMISEDPREMISESAFTERTHECONTRACTISSIGNED,NOSUCHDAMAGEOR LOSSSHALLRELIEVETHECONTRACTORFROMCONTRACTOROBLIGATIONTOCOMPLETETHEWORK
8.PRIORTOTHESTARTOFDEMOLITION:
A.ANOTICEWITHMINIMUM10DAYSINADVANCESHALLBEGIVENTOADJOININGPROPERTYOWNERWITHWORK DESCRIPTION,TIMEFRAME,SCHEDULE,ANDCONTRACTINFORMATIONOFTHEGENERALCONTRACTORAND THEDEPARTMENTOFBUILDINGS
B.A24TO48HOURSADVANCENOTICESHALLBEGIVENTODEPARTMENTOFBUILDING212-393-2550
C.A24HOURSADVANCENOTICEINWRITTENSHALLBEGIVENTOPROJECTENGINEER.
9.ASIGNATTHEHEIGHTNOMORETHAN12FEETABOVEGROUNDSHALLBEERECTED,CONTAINING A.THENAME.ADDRESSANDTELEPHONENUMBEROFTHEOWNEROFTHEPROPERTY B.THENAME,ADDRESSANDTELEPHONENUMBEROFTHEDEMOLITIONCONTRACTOR C.THEPHONENUMBERFORREPORTINGCOMPLAINTS
10.SIDEWALKSHEDSSHALLBEDESIGNEDBYLICENSEDPROFESSIONALENGINEERANDTHEDRAWINGSHALLBEAT SIDE.DRAWINGSSHELLBESUBMITTEDFORAPPROVALTOD.O.BPRIORTOCOMMENCINGDEMOLITION.
11.SIDEWALKSHEDSHALLBEINSTALLEDPRIORTOTHECOMMENCEMENTOFDEMOLITIONWORK
12.ALLPIPEANDHANGINGSCAFFOLDINGSHALLBECOVEREDBY(0.5''WIREMESH)VERTICALSAFETYNETTING.
13.LIFTINGHOISTSHALLBEAPPROVEDBYLICENSEDP.EORR.A
14.AHOTLINENUMBERSHALLBEPROVIDEDATTHESITEFORTELEPHONINGTHETHEDEPARTMENTOFBUILDING ANDTOCLOSEOFFASTREETFORSAFETYPURPOSESTHISINFORMATIONISTOBEDISPLAYEDONASIGN.
15.ASITESAFETYLOGSHALLBEKEPTATTHESITEANDTOBEAVAILABLEFORINSPECTIONATANYTIMEDURINGTHE COURSEOFCONSTRUCTIONORDEMOLITION.
16.ALLREQUIREDREGULATORYAPPROVALAND/ORPERMITSWILLBEOBTAINEDBYCONTRACTORBEFORE COMMENCINGANYWORK.
17.ALLDEMOLITIONANDREMOVALSSHALLBEPERFORMEDINACCORDANCEWITHALLAPPLICABLEFEDERAL,STATE ANDNYC2014BUILDINGCODELAWS,SECTIONSBC3306REGULATIONSANDPROJECTSPECIFICATIONS.
18.BEFORESTARTINGANYWORK,CONTRACTORSHALLEXAMEXIT,STRUCTURECONDITIONINWHICHTHEWORKIS TOBEPERFORMED,CHECKALLTHEWORKADJOININGORATUNDERLAYLOCATIONS,REPORTTOTHEARCHITECT ANYANDALLCONDITIONSWHICHMAYINTERFEREWITHOROTHERWISEAFFECTORPREVENTTHEPROPER EXECUTIONANDCOMPLETIONOFTHEWORK,DONOTSTARTTHEWORKUNTILSUCHCONDITIONSHAVEBEEN EXAMINEDANDCOURSEOFACTIONSMUTUALLYAGREEDUPON.
19.PRIORTOTHESTARTOFDEMOLITION,THECONTRACTORSHALLCALLTOTHEATTENTIONOFTHEOWNERANY DAMAGE,CRACKSORTHEIMPERFECTIONSINTHEWORKADJACENTTODEMOLITIONSAREAS.
20.BEFORESTARTINGDEMOLITIONOPERATIONS,PROVIDETHENECESSARYSAFETYPROTECTIVEDEVICEWHERE REQUIREDANDINSTRICTACCORDANCEWITHOSHARULESANDREGULATIONS.
21.BEFORESTARTINGDEMOLITIONOPERATIONS,THECONTRACTORSHALLWORKWITHOWNERLOCATEAND IDENTIFYALLUTILITYCONNECTIONS(WATER,GAS,ELECTRICITY,STEAM,ETC).ANDARRANGETODISCONNECT,OR SHUTOFF,ANDSEAL,ORCAPOFFINDICATEDUTILITIESWITHUTILITYCOMPANY.
22.ALLDEMOLISHEDMATERIALSHALLBEREMOVEDFROMPROJECTSITEONAREGULARBASISANDLEGALLY DISPOSEOFTHEMINAEPA-APPROVEDLANDFILL.DEBRISREMOVALPROCESSSHOULDBELAYOUTACCORDINGTO DEMOSCHEDULEANDCONTAINERCAPACITYANDLOCATION.
23.THECONTRACTORSHALLOBTAINANDPAYFORFEES,PERMITSANDINSPECTIONSWHENIFREQUIREDIN CONNECTIONWITHTHEDEMOLISHEDMATERIALSREMOVALANDDISPOSALOFALLDEBRIS.
24.REPAIRAND/ORREPLACEEXCITINGITEMSNOSCHEDULEDNONOTEDTOBEDEMOLISHED,ANDNOTSPECIFIEDTO BEREMOVED,BUTWHICHBECOMEDAMAGEDDURINGTHEPROGRESSOFTHEWORK,MAKEANYANDALLSUCH REPAIRS,REPLACEMENTSANDMODIFICATIONSTORESTORETHEDAMAGEITEMSTOTHEIRORIGINALCONDITIONAT THETIMEOFDAMAGE,TOTHESATISFACTIONOFANDATADDITIONALCOSTTOTHEOWNER.
25.CLEANADJ.STRUCTURESANDIMPROVEMENTSOFDUST,DIRT,ANDDEBRISCAUSEDBYDEMOLITIONOPERATIONS. RETURNADJ.AREASTOPREVIOUSCONDITIONAFTERDEMOLITIONWORKISCOMPLETE.
26.IFMATERIALSSUSPECTEDOFCONTAININGHAZARDOUSMATERIALSAREENCOUNTERED.DOMOTDISTURB IMMEDIATELYNOTIFYENGINEERANDOWNER.OWNERWILLREMOVEHAZARDOUSMATERIALUNDERASEPARATE CONTRACT.
27.LANDFILLRECORDS:INDICATERECEIPTANDACCEPTANCEOFHAZARDOUSWASTESBYALANDFILLFACILITY LICENSEDTOACCEPTHAZARDOUSWASTES.
28.STORAGEORSALEOFREMOVEDITEMSORMATERIALSONSITEITNOTPERMITTED
29.NOBEARINGPARTITIONWALLSHALLBEREMOVEDFROMANYFLOORUNTILTHEFLOOR FRAMINGSYSTEMIFTHEFLOORABOVEANDLOWERED,ALLHEADERBEAMSANDHEADERSTAIR OPENINGSANDCHIMNEYSSHALLBECAREFULLYEXAMINEDAND,WHEREREQUIRED,SHALL SHAREDFROMTHECELLARFLOORTHROUGHSUCCESSIVEFLOORS.
30.THEWORKWILLCOMPLYWITHALLAPPLICABLESECTIONOFCHAPTER33OFTHENYCBUILDING CODEANDALLOSHA1926STANDARDSFORCONSTRUCTION.
31.THESITESAFETYPLANSHALLINCLUDEASTATEMENTTHATPRIORTOPERFORMINGANYWORK ONTHEPROJECTALLWORKERSSHALLHAVESUCCESSFULLYCOMPLETED,WITHINTHEPREVIOUS FIVECALENDARYEAR,ATENHOURCOURSEAPPROVEDBYTHEUNITEDSTATESDEPARTMENTOF LABOROCCUPATIONALSAFETYANDHEALTHADMINISTRATIONINCONSTRUCTIONINDUSTRY SAFETYANDHEALTH,ORBYTHECOMMISSIONERCOVERINGSUBSTANTIALLYTHESAMEMATERIAL, SUCCESSFULCOMPLETIONOFSUCHTRAININGCOURSESHALLBEEVIDENCEDBY(A) PRESENTATIONOFABONAFIDECOURSECOMPLETIONCARD,(B)COPYOFSUCHCARD,(C)A TRAININGROSTER.ATTENDANCERECORDOROTHERDOCUMENTATIONFROMTHECERTIFIED TRAINERPENDINGTHEISSUANCEOFSUCHCARDOR(D)OTHERVALIDPROOFWHICHMAYBE APPROVEDBYTHECOMMISSIONED,SUCHEVIDENCESHALLBEREADILYAVAILABLETOTHE COMMISSIONERUPONREQUEST.
32.ASTATEMENTTHATALLWORKSEMPLOYEDONTHESITEWILLRECEIVEDSITE-SPECIFIC SAFETYORIENTATIONPROGRAM.THISPROGRAMSHALLINCLUDEREVIEWOFANYHAZARDOUS ACTIVITIESOFTHEJOBTHATARERELEVANTTOTHETASKSANDACTIVITIESTOBEPERFORMED, ALLWORKERSMUSTATTENDSUCHAPROGRAMNOLATERTHATSEVENDAYSAFTERCOMMENCING THEIREMPLOYMENT.
33.ALLBARRIERSLOCATEDINTHESTREETMUSTBEINSTALLEDASPERDOTREGULATIONSAND MANUFACTURESSPECIFICATIONS.
NOTIFICATIONS
I.FORDEMOLITIONONLYCONTACTTHECENTER24HOURSBEFORESTARTOFWORKAT(212) 227-4416
II.FOREXCAVATIONONLYCONTACTTHECENTER24HOURSBEFORESTARTWORKAT(212) 393-2550
III.TOREPORTANINCIDENTORACCIDENTINVOLVINGACRANEORDERRICK,CALL(212)393-2127.
FIREPROTECTION&DUSTCONTROLNOTE
1.CONTRACTORSHALLPROVIDEPORTABLEFIREEXTINGUISHERATLEAST2-A:20B:C RATINGONSITEDURINGDEMOLITION.
2.CONTRACTORSHALLOBTAINANAGREEMENTFROMADJACENTPROPERTYOWNERFORTHE USEOFTHEIRWATERASWATERSOURCETOCONTROLTHEDUSTDURINGDEMOLITIONOR USEEXISTINGFIREHYDRANTWITHAREQUIREDDEPPERMIT.
3.ALLMEANSOFFIREDETECTION&SUPPRESSIONSHALLBEACCORDANCEWITHDNYRULES& REGULATIONS.
4.CONTRACTORSHOULDPROVIDESUFFICIENTEATERCONTROLTHEDUSTDURING DEMOLITION,FIREHYDRANTSSHALLBITBEOPENEDTOACCOMPLISHTHEREQUIREMENT UNLESSAFIREHYDRANTUSEPERMITISINEFFECT.
5.THEEXISTINGBUILDINGSSPRINKLERSYSTEM,STANDPIPEANDSIAMESECONNECTIONS WERENOTOBSERVEDATTHETIMEOFJOBSITEVISIT.
HOTWORKSNOTES:
TRAINEDPERSONNEL(FIREWATCH)WHOAREINATTENDANCEDURINGTHEENTIREHOTWORK OPERATIONANDAREIMMEDIATELYAVAILABLETOEXTINGUISHAFIREORTAKEOTHEREFFECTIVE ACTIONIFNEEDED
SAFETYPROTECTION:
ANYONEWORKINGWITHINCONSTRUCTIONSAFETYZONEHASTOFOLLOWTHEOSAH CONSTRUCTIONSAFETYPROTECTIONREQUIREMENT.EVERYONEMUSTBEWEAR-HEAD,STEEL TOEBOOTS,RESPIRATOR,SAFETY-GLASS.IFANYONEWORKINGONTHEPLATFORMIS6FEET ABOVEGROUNDORFLOORMUSTWEARBELTORHARNESS

CELLARFLOORDEMOLITIONPLAN
PROPERTYLINE

DEMOLITIONNOTES:
1.THECONTRACTORMUSTOBTAINALLAPPLICABLEPERMITSANDPERMISSIONFROMNYC DOBANDNYCDOTPRIORTOCRANEUSEONSITE.GENERALCONTRACTORSHALLFILE CRANEPERMITUNDERSEPARATEDAPPLICATION,SEEFD-101FORPERMITAPPLICATION LISTTABLE.
2.ASBESTOSABATEMENTCERTIFICATE(WHENREQUIRED)SHOULDBEAVAILABLEATTHE TIMEOFAPPLYINGFORDEMOLITIONPERMITS.
3.NOPERSONNELISPERMITTEDONTHEDEMOLITIONSITEDURINGUSINGMECHANICAL EQUIPMENTEXCEPTOPERATORANDAUTHORIZEDPERSONNEL.
4.NOPERSONNELISPERMITTEDATTHEUNDERSIDEDURINGOPERATIONOFCRANE.
5.CONTRACTORSHALLOBTAINPERMITFORSIDEWALKSHED,OVERHEADPROTECTION SHED,SCAFFOLDING,ANDCONSTRUCTIONFENCEUNDERSEPARATEAPPLICATION.
6.CONTRACTORISRESPONSIBLEFOROBTAINANAGREEMENTFROMADJ.PROPERTY OWNERTOINSTALLSAFETYNETTING,FIRERETARDANTROOFPROTECTION, CONSTRUCTIONFENCE,OVERHEADPROTECTIONSHEDANDPLYWOODPROTECTION WITHINTHEIRPROPERTY.
7.CONTRACTORSHOULDPROVIDEATLEASTONEQUALIFIEDWATCHPERSONATTHESITE DURINGDEMOLITION.AQUALIFIEDWATCHPERSONSHALLBEFAMILIARWITHEMERGENCY NOTIFICATIONPROCEDURESTOTHEFDNY,SHALLPASSESAVALIDSECURITYGUARD CERTIFICATEFROMTHESTATEOFNEWYORKSHALLHOLDAVALIDFIREGUARD CERTIFICATEFROMFDNY.
ADJ.12''INDEPENDENT BRICKWALL (NOWORK)
2STORY+CELLAR FRAMEBUILDING HEIGHT:24'8"
135WOODBINEST BL:3350LT:43
OBTAINADJPROPERTYOWNER CONSENTTOINSTALL SCAFFOLDING
CONTROLLED ACCESSZONE TEMPORARY FENCING
ADJ.12''INDEPENDENT BRICKWALL (NOWORK)
ADJ.12''INDEPENDENT BRICKWALL (NOWORK)
2STYFRAMEBLDG HEIGHT:27'0"

INFOSIGN INSTALLOVERHEAD PROTECTIONSHED(TYP.) HT:12'-0''
SIDEWALK FOR PEDESTRIAN
WOODBINESTREET
CONCRETESIDEWALK

8.CONTRACTORSHALLUSESEXTRACAUTIONWHENWORKINGWITHINORCLOSELYTOADJ. PROPERTY.ALLDEBRISMUSTBEPULLEDINSIDEANDSLOWLYLOWEREDBYCHUTE.
9.CONTRACTORSHOULDPROVIDESUFFICIENTWATERTOCONTROLTHEDUSTDURING DEMOLITION.USEOFAHYDRANTREQUIRESADEPPERMITANDTHISPERMITSHALLBE KEPTONSITEATALLTIMES.
PREPARATIONSTAGEANDDEMOLITIONOPERATIONNOTES:
1.INSTALLSCAFFOLDINGS,DEBRISCHUTE,CONSTRUCTIONFENCE,CONTROLLED ACCESSZONEANDTEMP.BRACINGOREXTERIORWALLSASINDICATEDFROMFD-101 THROUGHFD-104.
2.REMOVEEXIST.GLASSINTHEDOORS,WINDOWS,ANDFIXTURESBEFORESTARTOF DEMOLITIONPERBC3306.9.8.
3.REMOVEEXIST.CONCRETESTEPSBEFORETHESTARTOFDEMOLITION.
4.REMOVEEXIST.ELEVATORCARTANDASSEMBLYBEFORETHESTARTOF DEMOLITION.
5.SIDEWALKSSHALLBECLEAREDOFDEBRISORCONSTRUCTIONMATERIALSATALL TIME.
6.ALLMECHANICALDEMOLITIONSHALLBEPERFORMEDBYSKILLEDLICENSED MECHANICS.
7.THECONTRACTORSHALLASSUMEDRISKREGARDINGDAMAGEORLOSSWHETHERBY REASONOFFIRE,THEFTORANYOTHERCASUALTYTOTHEDEMISEDPREMISES AFTERTHECONTRACTISSIGNED,NOSUCHDAMAGEORLOSSSHALLRELIEVETHE CONTRACTORFROMCONTRACTOBLIGATIONTOCOMPLETETHEWORK.
8.THECONTRACTORSHALLDISPOSEOFALLDEMISEDMATERIALSINCLUDINGCARTING AWAYDEMOLISHEDMATERIALSFROMTHESITEINAMANNERAPPROVEDBYTHE BUILDINMANAGEMENTANDGOVERNMENTREGULATIONIMMEDIATELYAFTER DEMOLITIONUNLESSOTHERWISEINSTRUCTED.
9.EXCAVATORANDOTHERHEAVYMECHANICALEQUIPMENTSHALLBELOCATEDNOT LESSTHAN1.5TIMESDEPTHOFDEMOFOOTINGFROMEDGEOFTHEEXCAVATION BUILDINGORSTRUCTURES.
10.PROVIDESAFETYFLAGMANFOREACHADJACENTPROPERTYSIDE/REARYARDTO MAKESURENOBODYWILLWALKTHROUGHTHATAREA.
11.ALLDIMENSIONANDELEVATIONINDICATEDWITHINPLANSHALLBEVERIFIEDINFIELD BYCONTRACTOR.
SEPARATEAPPLICATION
EXIST.2STORYFRAME TOBEREMOVEDINA SEPARATEAPPLICATION
PROPERTYLINE
ADJ.12''INDEPENDENT BRICKWALL (NOWORK)

PREPARATION:
STAGE1:
INSTALLCONSTRUCTIONFENCEREMOVEMETALDOOR,WINDOWSANDANYOTHERACCESSORY STRUCTURE,SUCHASREMOVABLECONTAINER,METALCAGING,FRAMESHED,RAISEDCONCRETEINSTALL SCAFFOLDING,SIDEWALKSHED,CHUTEANDTEMPORARYWALLBRACING(8'TYP.)ASINDICATEDONFD-101 THROUGHDEMOLITIONPLANONFD-204,ADJACENTENTRANCESHALLNOTBEBLOCKED,SCAFFOLDING SHALLBEINSTALLEDWITHDOUBLELAYERVERTICALDEBRISNETTINGANDATLEAST3'-6"HIGHERABOVE ROOF.
DEMOLITIONSEQUENCE:
STAGE1:
STARTHANDDEMOLITIONOFROOFING,REMOVEROOFMEMBRANES,INSULATIONLAYERS,ANDPLYWOOD, EXPOSEALLSTRUCTURALMEMBERSTHATSUPPORTTHEROOF.
STAGE2:
STARTHANDDEMOLITIONOFWOODJOISTONROOFFLOOR.WORKEROPERATEFROMAROLLING SCAFFOLDINGCUTTINGJOISTINTOSMALLPIECESANDTHENCAREFULLYLOWERINGTOLOWERFLOOR. EACHPIECESHALLLIMITEDTO10FEETINLENGTH.NODEBRISACCUMULATIONONFLOORISPERMITTED.
STAGE3:
DISCONNECTALLPLUMBINGLINESANDREMOVEALLTHEEXISTINGPLUMBINGFIXTURESFROMTHE TOILETONTHE2NDFLOOR.
STAGE4:
SAFETYHANDDEMOLITIONFORTHEINTERIORANDEXTERIORWALLSON2NDFLOOR. THEWALLSHALLBEDEMOLISHEDLAYERBYLAYERACCORDINGTODETAILANDPROCEDUREASSHOWNIN DETAIL"4"ONFD-106.EACHLAYERSLIMITEDTO1'HEIGHTOR2BLOCKS,WHICHEVERISSMALLER.THE SEQUENCEOFDEMOLITIONISINSUCHAWAYTHATTHEINTERNALWALLSWILLBEDEMOLISHEDFIRST FOLLOWEDBYTHEEXTERIORFRAMEWALLS
EGRESSNOTES:
1.DURINGDEMOLITION,THEMEANSOFEGRESSAND EXIST.STAIRSSHALLNOTBEBLOCKEDBYEQUIPMENT, DEBRISANDMATERIAL.THESTAIRSHALLBELIGHTED ATALLTIME.
DEBRISREMOVALNOTES:
1.ALLDEBRISSHALLNOTBETHROWNORDROPPEDFROM THEBUILDING,MUSTBEDISMANTLEDPIECEBYPIECE, CHAINED,LASHEDANDCAREFULLYLOWERBYCHUTE.
2.ALLDEBRISMUSTBECLEANEDOUTFROMTHE WORKINGAREABEFOREPROCEEDINGTONEXTSTAGE. NODEBRISACCUMULATIONONFLOORISPERMITTED. 3.ALLDEBRISSHALLBECLEANEDOFFFLOORSDAILY.
INTERIORWALLS
THEREMOVALOFTHEINTERIORWALLSHASBEEN COORDINATEDWITHTHELOADCAPACITYOFTHE EXTERIORWALLSANDFLOORS.

TEMPORARY FENCING
CONTROLLED ACCESSZONE
ADJ.12''INDEPENDENT BRICKWALL (NOWORK)
ADJ.12''INDEPENDENT BRICKWALL (NOWORK) 2STYFRAMEBLDG HEIGHT:27'0"


PROPERTYLINE
TEMPORARY FENCING
CONTROLLED ACCESSZONE
ADJ.12''INDEPENDENT BRICKWALL (NOWORK)
DEMOLITIONSEQUENCE:
STAGE5: DISCONNECTALLPLUMBINGANDGASLINESANDREMOVEALLTHEEXISTINGPLUMBINGANDGAS OPERATEDFIXTURESFROMTHEKITCHENANDTOILETONTHE1STFLOOR.
STAGE6:
STARTHANDDEMOLITIONOFTHEPORCHROOFAND2NDFLOORDECK,REMOVEFLOORMEMBRANES, INSULATIONLAYERS,ANDPLYWOOD,EXPOSEALLSTRUCTURALMEMBERSTHATSUPPORTTHEFLOOR.
STAGE7:
STARTHANDDEMOLITIONOFWOODJOISTON2NDFLOORDECKANDPORCHROOF.WORKEROPERATE FROMAROLLINGSCAFFOLDINGCUTTINGJOISTINTOSMALLPIECESANDTHENCAREFULLYLOWERINGTO LOWERFLOOR.EACHPIECESHALLLIMITEDTO10FEETINLENGTH.NODEBRISACCUMULATIONONFLOOR ISPERMITTED.
STAGE8:
STARTHANDDEMOLITIONOFSTAIRCASEGOINGTOTHE2NDFLOOR.
STAGE9:
SAFETYHANDDEMOLITIONFORTHEINTERIORANDEXTERIORWALLSON1STFLOOR. THEWALLSHALLBEDEMOLISHEDLAYERBYLAYERACCORDINGTODETAILANDPROCEDUREASSHOWNIN DETAIL"4"ONFD-106.EACHLAYERSLIMITEDTO1'HEIGHTOR2BLOCKS,WHICHEVERISSMALLER.THE SEQUENCEOFDEMOLITIONISINSUCHAWAYTHATTHEINTERNALWALLSWILLBEDEMOLISHEDFIRST FOLLOWEDBYTHEEXTERIORFRAMEWALLS
EGRESSNOTES:

ADJ.12''INDEPENDENT BRICKWALL
1.DURINGDEMOLITION,THEMEANSOFEGRESSAND EXIST.STAIRSSHALLNOTBEBLOCKEDBYEQUIPMENT, DEBRISANDMATERIAL.THESTAIRSHALLBELIGHTED ATALLTIME.
DEBRISREMOVALNOTES:
1.ALLDEBRISSHALLNOTBETHROWNORDROPPEDFROM THEBUILDING,MUSTBEDISMANTLEDPIECEBYPIECE, CHAINED,LASHEDANDCAREFULLYLOWERBYCHUTE. 2.ALLDEBRISMUSTBECLEANEDOUTFROMTHE WORKINGAREABEFOREPROCEEDINGTONEXTSTAGE. NODEBRISACCUMULATIONONFLOORISPERMITTED. 3.ALLDEBRISSHALLBECLEANEDOFFFLOORSDAILY.
INTERIORWALLS
COORDINATEDWITHTHELOADCAPACITYOFTHE EXTERIORWALLSANDFLOORS.



BEREMOVEDINA SEPARATEAPPLICATION
EXIST.2STORYFRAME TOBEREMOVEDINA SEPARATEAPPLICATION
PROPERTYLINE
EGRESSNOTES:
DEMOLITIONSEQUENCE:
STAGE10:
DISCONNECTALLPLUMBING,ELECTRICALANDGASLINES,REMOVEALLTHEEXISTINGBATHROOM FIXTURES,HOTWATERTANKANDBOILERFROMTHECELLARFLOOR,ELECTRICANDGASMETERS.
STAGE11:
STARTHANDDEMOLITIONOFTHE1STFLOORDECK,REMOVEFLOORMEMBRANES,INSULATIONLAYERS, ANDPLYWOOD,EXPOSEALLSTRUCTURALMEMBERSTHATSUPPORTTHEFLOOR.
STAGE12:
STARTHANDDEMOLITIONOFWOODJOISTOF1STFLOORDECK.
STAGE13:
STARTHANDDEMOLITIONOFBRICKSTAIRON1STFLOORMAINENTRANCEANDDEMOLISHTHEPORCH.
STAGE14:
SAFETYHANDDEMOLITIONFORTHEINTERIORWALLSONCELLARFLOOR.THEWALLSHALLBE DEMOLISHEDLAYERBYLAYERACCORDINGTODETAILANDPROCEDUREASSHOWNINDETAIL"4"ON FD-106.EACHLAYERSLIMITEDTO1'HEIGHTOR2BLOCKS,WHICHEVERISSMALLER.THESEQUENCEOF DEMOLITIONISINSUCHAWAYTHATTHEINTERNALWALLSWILLBEDEMOLISHEDFIRSTFOLLOWEDBYTHE PARTIALEXTERIORFRAMEWALLS
STAGE15: STARTHANDDEMOLITIONOFSTAIRCASEGOINGFROMTHECELLARUPTOTHE1STFLOOR.
ADJ.12''INDEPENDENT BRICKWALL
1STFLOORDECK MEMBRANE& WOODENJOISTS TOBEREMOVED
TEMPORARY FENCING
CONTROLLED ACCESSZONE
ADJ.12''INDEPENDENT BRICKWALL (NOWORK)

ADJ.12''INDEPENDENT BRICKWALL (NOWORK) 2STYFRAMEBLDG HEIGHT:27'0"


1.DURINGDEMOLITION,THEMEANSOFEGRESSAND EXIST.STAIRSSHALLNOTBEBLOCKEDBYEQUIPMENT, DEBRISANDMATERIAL.THESTAIRSHALLBELIGHTED ATALLTIME.
DEBRISREMOVALNOTES:
1.ALLDEBRISSHALLNOTBETHROWNORDROPPEDFROM THEBUILDING,MUSTBEDISMANTLEDPIECEBYPIECE, CHAINED,LASHEDANDCAREFULLYLOWERBYCHUTE.
2.ALLDEBRISMUSTBECLEANEDOUTFROMTHE WORKINGAREABEFOREPROCEEDINGTONEXTSTAGE. NODEBRISACCUMULATIONONFLOORISPERMITTED.
3.ALLDEBRISSHALLBECLEANEDOFFFLOORSDAILY.

ADJ.12''INDEPENDENT
EXIST.FRAMEGARAGETO BEREMOVEDINA SEPARATEAPPLICATION
EXIST.2STORYFRAME TOBEREMOVEDINA SEPARATEAPPLICATION

DEMOLITIONSEQUENCE:
STAGE16: APPLYWEATHERPROOFINGFORNEWLYEXPOSUREWALLOFADJ.BUILDING,SEEDETAIL'5'ONFD-106.
STAGE17:
STARTHANDDEMOLITIONOFSLABONGRADEANDCONCRETEFOUNDATIONWALL/FOOTINGOF BUILDING.THEFOUNDATIONWALLANDFOOTINGSHALLBEDEMOLISHEDSECTIONBYSECTIONANDNOT EXCEED6'MAX.SPACE.SEEDETAIL'5'ONFD-106.ONCEEACHSECTIONREMOVED,BACKFILLTHESECTION IMMEDIATELYWITHCLEANSOILMATERIAL.
STAGE18: ONCELASTSTAGEFINISHED,BACKFILLIMMEDIATELYWITHCLEANSOILMATERIALTOGROUNDLEVEL.
MAINTAINADJACENTPROPERTY'SSTRUCTURALSTABILITY.REQUESTTOLEAVEPARTIALFOUNDATION WALLANDFOOTINGWITHIN4FEETALONGTHEEACHSIDEOFDEMOLITIONSITEASINDICTEDONFD-103 THROUGHFD-104.
CONSTRUCTIONFENCENOTES:
THECONSTRUCTIONFENCEWILLBERELOCATEDTOPROPERTYLINE.AFTERCOMPLETIONOFDEMOLITION ALLBUILDINGENCLOSEDBYTHESAMECONSTRUCTIONFENCE.
EGRESSNOTES:
1.DURINGDEMOLITION,THEMEANSOFEGRESSAND EXIST.STAIRSSHALLNOTBEBLOCKEDBYEQUIPMENT, DEBRISANDMATERIAL.THESTAIRSHALLBELIGHTED ATALLTIME.
DEBRISREMOVALNOTES:
1.ALLDEBRISSHALLNOTBETHROWNORDROPPEDFROM THEBUILDING,MUSTBEDISMANTLEDPIECEBYPIECE, CHAINED,LASHEDANDCAREFULLYLOWERBYCHUTE.
2.ALLDEBRISMUSTBECLEANEDOUTFROMTHE WORKINGAREABEFOREPROCEEDINGTONEXTSTAGE. NODEBRISACCUMULATIONONFLOORISPERMITTED.
3.ALLDEBRISSHALLBECLEANEDOFFFLOORSDAILY.
INTERIORWALLS
THEREMOVALOFTHEINTERIORWALLSHASBEEN



NOTE:WIDTHMAYBEREDUCEDTO5'ON NARROWSIDEWALKSASREQUIREDTO MAINTAINSIDEWALKCLEARANCEOF3' (THREEFEET)ATTHETREEBARRIERSONLY.

4''X4''POSTS,TYPICAL
2''X8''PLANKS ALLAROUND
5'-0'' 5'-0''
SECTIONA-A
DETAILS-PROTECTIONTREEBARRIER
SNOWFENCETYPETREEWRAP
2''X8''PLANKS,ALLAROUND
4''X4''POSTS,TYPICAL
2''X8''BRACES,ALLAROUND 2''X8''PLANKS,ALLAROUND 10'' 4' TYPE A 6' TYPE B
1TYP.TREEPROTECTIONDETAIL
SCALE:N.T.S ADJ.PROPERTY
1.PATCHALLHOLESORCRACKS,AND MAKESURFACECLEANANDFREE FROMDIRT,DUSTGREASEOIL,ETC 2.APPLYPARGECOATANDASCERTAIN THECOATINGISINSOUND CONDITION.
3.APPLYLATEXBASEDRYLOK MASONRYWATERPROOFERTOADJ. PROPERTYEXPOSEDWALL.
4.AFTER3HOUR,APPLYTHESECOND COATINGOFWATERPROOFING.
RECOMMENDEDFILMTHICKNESS/COAT: 13-21WETMILS/COAT
2TYP.WEATHERDETAIL
SCALE:N.T.S
TYP.HANDDEMOCMU/BRICKWALLDETAILANDPROCEDURE4SCALE:N.T.S NOTE: WALLSSHALLBEHANDDEMOLAYERBYLAYER,EACHLAYERIS
FASTENTEMP.WALLBRACINGTOEXIST.WOOD STUDW/10X3WOODSCREW@12''O.C.(TYP.) 2X6TIMBER(TYP.)
2X6TIMBER(TYP.)
2X4TIMBERSTIFFENERCONNECTED TODIAGONALSUPPORTWITHSCREW (ONBOTHSIDES)
2X6TIMBER(TYP.)

TYP.OVERHEADPROTECTION&SIDEWALKSHEDDETAIL3SCALE:N.T.S