Würth Coolius Brochure

Page 1

2008 coolius.qxd:coolius 2008.qxd

15/2/08

16:31

Page 1

COOLIUS the program for automotive air conditioning systems


2008 coolius.qxd:coolius 2008.qxd

15/2/08

16:31

Page 2

Accident prevention Please note! Refrigerants in combination with open flames or hot surfaces can produce toxic gases (fluor gas, phosgene). Even at low concentrations these gases are recognisable by their pungent odour. Serious frostbite will result, if liquid refrigerant comes into contact with skin. Therefore, always wear protective goggles (0899 102 110) and gloves (0899 430). Leather or fabric gloves are not suitable for this purpose. Gaseous refrigerant is heavier than air. Therefore, there is a danger of suffocation near the floor level or in work pits. Always provide sufficient ventilation when handling refrigerants.

First aid Always make sure of the following when handling refilling bottles: • Do not expose bottles to sunlight or heat. • Protect bottles against frost. • Transport bottles upright. • Do not drop bottles. • Always close bottles securely. Filling bottles with one valve Bottles without ascending pipe must be turned upside down for the purpose of extracting liquid refrigerant, ie filling valve pointing downwards. Filling bottles with two valves In these bottles, the ascending pipe is located inside. The bottle must not be turned upside down.

If fumes are inhaled: Move patient to fresh air location, keep warm, let patient rest. If necessary, give oxygen. Call physician immediately. In case of respiratory standstill or irregular breathing, (perform artificial respiration) Call physician immediately. In case of cardiac arrest, (perform heart massage) Call physician immediately. After contact with skin: Flush affected area with water. After contact with eyes: Flush eyes with lots of water for at least 15 minutes. Consult physician. (1895 100 010 eye wash dispenser).


2008 coolius.qxd:coolius 2008.qxd

15/2/08

16:31

Page 3

COOLIUS

air conditioning program HOW YOU CAN BENEFIT FROM IT: Servicing of air conditioning systems is one of the growth markets of the future. Almost all new automobiles will be equipped with standard air conditioning in the future. Even today up to 72% of small and medium cars come equipped with factory air conditioning. Air conditioning system disinfection and regular service checks represent additional services for you and, above all, for the health of your customers. Refrigerants must not be mixed. The refrigerant specified for an air conditioning system must be used exclusively. Air conditioning systems that are filled with the refrigerant R12, cannot and must never be topped up or refilled with the refrigerant R134a (different components and compressor oils are required). However, an R12 air conditioning system can be converted to R134a using a retrofit process.


2008 coolius.qxd:coolius 2008.qxd

15/2/08

16:31

Page 4

Notes for working on air conditioning systems

Air conditioning checklist

a) It is of vital importance to collect the refrigerant in a service unit when draining an air conditioning system. Under no circumstances may the refrigerant be discarded outside or into the sewer.

The most important prerequisite when working on air conditioning systems is cleanliness. Any foreign substances, such as air, moisture or dirt in the circulation will impair the function of the air conditioning system.

1) Make certain that the valves for high and low pressures at the air conditioning service unit are closed.

b) When using the service unit, it is important to observe the operating instructions by the manufacturer.

f) Prior to loosening refrigerant hose connections and connectors, these MUST be cleaned to remove all contaminates, in order to prevent any contamination of the system.

c) Pressure may still build up in an already drained air conditioning system due to remaining refrigerant residue in the compressor oil. d) Utmost caution is required when performing welding work near an air conditioning system. Care must be taken not to expose parts of the air conditioning system to excessive heat, since this may destroy the hoses and result in danger of explosion. e) After paint work is done on the car with subsequent drying in the baking chamber, air conditioning systems filled with R134a must not be exposed to temperatures higher than 70 to 80°C.

g) All open connectors must be closed immediately with sealing plugs (0964 764 026). Sealing with adhesive tape is NOT suitable. h) Always make sure that tools, measuring devices and replacement parts are free of any contaminates. Refrigerant is highly hygroscopic, that is it immediately absorbs humidity from the air. Keep the refrigerant container closed at all times. i) O-rings must always be replaced after connections are loosened and must be lubricated with refrigerant oil (PAG) prior to installation. j) If the air conditioning system has been opened for service, always replace the dryer cartridge. k) After completion, check all connections for leaks (0964 764 025 and 0964 764 009). Loss of refrigerant between 60-130 grams per year is normal. Even after an operating time of two to four years, under filling of the air conditioning system is normal. In these cases, topping up or refilling without replacement of components is required.

2) Connect the high pressure (red) and low pressure (blue) lines to the quick action couplings of the air conditioning system. 3) For the following checks, make sure that the engine is running at a constant speed of about 1500rpm. 4) Set the air conditioning system to maximum cold setting and the blower to maximum level (recirculation). 5) Temperature check: Attach a digital thermometer (0764 000 013) within the centre air outlet on the dashboard. The temperature reading at the centre air outlet should be between 3 to 6.5°C at an outside temperature of 20°C.For reference values refer to Diagram 1. Should the measuring values deviate from the reference values, perform a pressure check. 6) Pressure check: Verify whether or not the high and low pressure values at the pressure gauges are within the reference values: • low pressure • high pressure For reference values refer to Tables 1 and 2. 7) For possible causes of errors, if values are outside the tolerances: refer to Table 3. 8) Prepare for disinfection of air conditioning system: • Check and replace micro air filter. • Check drain tube of condenser for obstructions and clean it. • Check whether the air conditioning system functions properly with recirculation air and outside air supply (air conditioning systems should preferably operate with outside air only). • Now you can apply the disinfection spray in accordance with instructions for use.


2008 coolius.qxd:coolius 2008.qxd

15/2/08

16:31

Page 5

Reference values: R134a air conditioning systems with expansion valve:

Centre outlet temperature °C

Outside temperature (°C) 15 20 26 32 37

High pressure (bar) 8.0 - 10.5 8.0 - 12.8 10.5 - 13.5 15.7 - 19.5 16.5 - 22.5

Low pressure (bar) 0.6 - 1.2 0.6 - 1.2 0.6 - 1.4 0.6 - 2.0 1.2 - 2.3

Table 1 R134a air conditioning systems with throttle valve: Outside temperature (°C) 15 20 26 32 37

Outside temperature °C

High pressure (bar) 5.1 - 12.0 6.8 - 13.8 9.0 - 15.5 11.2 - 18.1 13.8 - 20.0

Low pressure (bar) 1.6 - 3.1 1.6 - 3.1 1.6 - 3.1 1.6 - 3.1 3.0 - 4.0

Table 2

Diagram 1

Attention! These tables contain reference values only. When checking pressures, always observe the values specified by the manufacturer of the air conditioning system.

Possible causes of errors: Low pressure higher than upper tolerance value

Low pressure lower than lower tolerance value

High pressure higher than upper tolerance value

High pressure lower than lower tolerance value

Table 3

• Defective compressor. • Intake and pressure side may have been switched at the compressor. • Expansion valve blocked in open position. If the compressor has variable displacement, small but quick pressure fluctuations occur at the low pressure side. • Defective displacement control valve; possibly not calibrated. • Slipping or faulty actuation of the magnetic clutch at the compressor. • Expansion valve or throttle valve obstructed or blocked. • Dryer cartridge saturated with moisture. • Displacement control valve of the compressor is blocked at highest capacity setting. • Obstruction in the low or high pressure area of the air conditioning system. • Thermostat defective. • Normal situation at extremely high outside temperatures (>44°C ). • Heat exchange at condenser does not function properly. • Air conditioning system has been over filled. • Air conditioning system is contaminated with air and/or foreign gases. • Defect of the displacement control valve in the compressor. • Possible obstructions in the high pressure area, between the condenser and compressor or dryer and evaporator (systems with expansion valve). • Normal situation at extremely high outside temperatures (>44°C ). • Obstructed or blocked expansion valve. • Air conditioning system is under filled. • Obstruction in the low or high pressure area between filter and evaporator. • Defective compressor.


2008 coolius.qxd:coolius 2008.qxd

15/2/08

16:31

Page 6

Ester Oil 250 ml 0892 764 035

PAG 46

low 250 ml 0892 764 025

PAG 100

high 250 ml 0892 764 026

PAG 150

very high 250 ml 0892 764 029

Service and lubrication of vehicle air conditioning systems in the refrigerant circulation. For cars, trucks, buses, agricultural equipment with R134a air conditioning systems. Guarantees optimal oil return flow to the air conditioning compressor. Excellent lubrication effect. Smooth running, extends the service life of the compressor and good refrigerant compression. Assures thermal stability in the compressor. To top up compressor oil according to the filling level recommended by the vehicle manufacturer, use the air conditioning service unit to add the compressor oil to the circulation . Protects against overheating. Good material compatibility.

Multigrade compressor oil

Attention! The filling quantities of air conditioning systems or filling levels of components (compressor) should be verified by the manufactures recommendations.

250 ml 0892 764 036

Attention: ESTER OIL Do not mix with other air conditioning oils, for instance, PAG oil. Store away from moisture and avoid storage of partially used cans.

Compatible with most commercial refrigerants*. Very good mixing properties. Guarantees optimal oil return flow to the air conditioning compressor.

New, high-quality synthetic oil with special additives for air conditioning compressor technology.

Can be mixed with ester and PAG oil. One oil for all purposes. Saving of costs. Excellent lubrication effect. Extends the service life of the compressor. Smooth running. Good refrigerant compression. Good refrigerant compression in the compressor. Assures thermal stability in the compressor. Protects against overheating. Attention: PAG OIL Do not mix with other air conditioning oils, for instance, ester oil. Store away from moisture and avoid storage of partially used cans.

Low sensitivity to moisture. Simpler handling in daily use. Good material compatibility. *Compatible Refrigerant R 227 R 413a R 407c R 410a R 404a R 507 R 125 R 23 R 744


2008 coolius.qxd:coolius 2008.qxd

15/2/08

16:31

Page 7

EVAPO® clean Set

EVAPO® clean

EVAPO® fresh

0964 764 3

0893 764 1

0893 139 1

No laborious dismantling of the evaporator required. The drilling of application holes is not necessary. Quick. Cost-effective.

Novel hygienic cleaning agent for use with EVAPOmat®.

Quick acting, odour absorber for use with the EVAPOmat®.

No laborious dismantling of the evaporator required. The drilling of application holes is not necessary. Simple, Quick, Cost-effective.

Can be used without previous experience. Simple, Fast, User-friendly.

Attachable application hose. Ideal positioning on the air intake nozzle of the air conditioning system. Superb utilisation of the active substance mist.

Simple, practical system. User friendly. Time-saving.

EVAPOmat® is suitable for the use of EVAPO®clean and EVAPO®fresh. Wide range of potential applications.

The same steps for all vehicle models. No additional application handbooks. No risk of incorrect use.

The same steps for all vehicle models. No additional application handbooks. No risk of incorrect use.

Available in the ORSY 200 case.

Set Contents 1 EVAPOmat® 2 EVAPOclean® 3 Mains adaptor 4 Application hose 5 Handbook

0891 764 2 0893 764 1 0891 764 21 0891 764 22

High-quality combination of raw materials. Odour molecules are absorbed and eliminated naturally. 100ml is sufficient for one application. Spreads a pleasant, fresh citrus fragrance. Good material compatibility. AOX free. Note: EVAPO®fresh may only be used in connection with EVAPOmat® 0891 764 2

5 4 2 1

Note: Permanently odour-free air conditioning only possibly with preventive regular application (at least 1–2 times a year). EVAPO®clean may only be used in conjunction with EVAPOmat®. 0891 764 2

Active ingredient mist settles on the entire surface. Reliable elimination of odours. Difficult places to access are reached by the active ingredient mist. Does not leave traces on glass or interior surfaces.

3

Before using the appliance for the first time, read the handbook thoroughly and follow the instructions therein. No liability is assumed for improper use or use of active substances other than those specified. Operate for no more then 15 minutes per application otherwise there is a risk of overheating and thus appliance failure. Must be allowed to cool down for at least 10 minutes before the next application. This information should only be seen as containing recommendations based on our experience. A preliminary test must be carried out.


2008 coolius.qxd:coolius 2008.qxd

15/2/08

16:31

Page 8

Leak detection additive

Air conditioning leak sealant additive

0892 764 010 - 7.5ml 0892 764 034 - 240ml

0892 764 500

Fluorescent additive for locating leaks in R 134a air conditioning systems.

For sealing O-rings, hoses and other joining elements made from rubber in R134a air conditioning systems.

No air conditioning service station necessary, easy and fast application.

CAUTION: Not suitable for sealing leaks at metallic components, (evaporators, compressors, condensers, etc.).

240ml contains enough for 32 uses in cars and 16 uses in HGVs. O-rings and seals not affected. Can be left in the air conditioning circuit. Meets the SAE J2297 specifications for R 134a, ester and PAG oil. Compatible with ester and PAG oil.

UV Leak detector lamp 12V/100W 0964 764 009

Add a leak detection additive to the refrigerant circuit. Then check the hoses for leaks with help of the UV leak detector lamp.The UV light causes any fluorescent fluid that may emerge from leaks to light up. The additive may remain in the system for an indefinite time after the leak search. Ideal for intermediate checks! With protective and effect-enhancing goggles. Goggles must be worn when working with the UV leak test lamp. Goggles enhance the illuminating effect of the additive. Compact size. Better access to tight spaces in the engine compartment, providing more accuracy in locating leaks.

Improves performance of compressors and reduces mechanical wear thanks to a TCP (Tricresyl-phosphate) additive. Ideally suited to older vehicles whose performance is deteriorating due to mechanical wear at the compressor. Compatible with ester andPAG oil. Contains no hazardous substances. Use of this product requires no air conditioning service.

1

Power cable approximately 4.5m long. Set Contents 12V lamp 0964 764 009 Spare bulb 12V / 100W 0764 720 091 UV Enhancing glasses 0899 108 2 Spare lens 0764 720 092

3 2

1

Air conditioning leak sealant additive set

3

0964 764 500

2

Leak detection kit

Note: For single use. Leaks that have already been treated with air conditioning leak sealant additive or that would lead in a very short time to all of the refrigerant being lost must be repaired by exchanging the O-rings and/or components.

0964 764 025

Set Contents 1 Discharge gun 0891 764 010 2 Filling adaptor 0764 000 114 3 Leak detection additive 0892 764 010

Set Contents 1 Discharge gun 0891 764 010 2 Filler adaptor for high-pressure side 0764 000 118 3 Leak sealant additive 0892 764 500


2008 coolius.qxd:coolius 2008.qxd

15/2/08

16:31

Page 9

Air conditioning system treatment 4 in 1 Leak Stop

Air conditioning system treatment Super A/C Leak Stop

0892 764 610

0892 764 600

Seals small leaks in rubber components of automotive air conditioning systems

Seals small leaks in metal and rubber components of automotive air conditioning systems

Complete A/C system treatment, all in 1 step. Premium Formulation stops leaks in automotive air conditioning systems. Also treats o-rings and gaskets. Compatible with mineral, ester and PAG oils. Reusable 9�charge hose complete with quality brass connectors.

Complete A/C system treatment, all in 1 step. Premium Formulation stops leaks in automotive air conditioning systems. Also treats o-rings and gaskets. Compatible with mineral, ester and PAG oils. Reusable 9�charge hose complete with quality brass connectors.

Contains a specially formulated additive for sealing leaks in A/C rubber hoses and all types of rubber o-rings and gaskets including HNBR, nitrile and neoprene. No need for expensive/time consuming repair work, faults are quickly remedied, thus saving you money. Amount of refrigerant escaping is reduced, resulting in less harm to the environment.

Contains specially formulated additives for sealing small refrigerant and lubricant leaks in evaporators, condensers and all types of rubber hoses, o-rings and gaskets No need for expensive/time consuming repair work, faults are quickly remedied, thus saving you money. Amount of refrigerant escaping is reduced, resulting in less harm to the environment.

Excellent Lubrication effect adds Ester oil to help lubricate the compressor. Extends the service life of the compressor. Smooth running and good refrigerant compression.

Excellent Lubrication effect adds Ester oil to help lubricate the compressor. Extends the service life of the compressor. Smooth running and good refrigerant compression.

Contains fluorescent active ingredients. Leaks glow when exposed to UV light and can be quickly identified. Can also be used for oily engines.

Contains fluorescent active ingredients. Leaks glow when exposed to UV light and can be quickly identified. Can also be used for oily engines.

Uses R-134a gas as a propellant which introduce a small charge of refrigerant into the air conditioning system (approximately 10%)

Uses R-134a gas as a propellant which introduce a small charge of refrigerant into the air conditioning system (approximately 10%)

WHICH LEAK STOP DO I USE if you have determined that the leak is located in a rubber hose, gasket or o-ring: USE 4 IN 1 LEAK STOP - 0892 764 610 if you have determined that the leak is located in a metal part: USE SUPER LEAK STOP - 0892 764 600

Reusable charging hose (9�) 0715 764 401


2008 coolius.qxd:coolius 2008.qxd

15/2/08

Air conditioning compressor guard kit 0964 764 110

Complete assortment of special tools for installation and removal of suction filters. Approximately 90% coverage of vehicle types with eight filter sizes. No cutting to size of pipes, no additional seals and no new leakage places. Protects against residual contamination in the refrigerant circulation.

16:31

Page 10

Digital LED thermometer 0764 000 013

For contact measurement of temperatures in heating, air conditioning and ventilation systems with a measuring range: –50°C to 260°C (selectable in Centigrade and Fahrenheit). Memory functions to recall and display minimum and maximum readings with selectable fast and normal sampling cycles Micro battery (0827 01) included.

Infrared thermometer 3 1 2

Set Contents 1 Filter sizing tool 2 Filter removal tools 3 Installation mandrel Suction Filters (three of each) 0.471” (11.96 mm) 0764 110 001 0.510” (12.95 mm) 0764 110 002 0.521” (13.23 mm) 0764 110 003 0.531” (13.49 mm) 0764 110 004 0.538” (13.67 mm) 0764 110 005 0.552” (14.00 mm) 0764 110 006 0.595” (14.02 mm) 0764 110 007 0.618” (15.70 mm) 0764 110 008 IMPORTANT: the refrigerant must be completely extracted and the air conditioning system must be evacuated!

0853 600 8

For touchfree measuring of surface temperatures via an integrated laser pointer. Easy-to-handle, practical and can be used anywhere to measure temperatures in a matter of seconds. With the laser pointer, the measurement point can be precisely pinpointed. Can be switched over between Celsius and Fahrenheit. Extremely fine measuring beam from 8:1. (Example: at a distance of 8cm the measuring diameter is 1cm). With integrated illuminated display temperature can be read even in poor light conditions.

Vinyl glove 0899 430 size universal


2008 coolius.qxd:coolius 2008.qxd

15/2/08

16:32

Page 11

Disinfectant spray

Surface disinfectant cleaner Disinfectant cloth

300ml 0893 764 10

0893 764 05

0890 151 / 0890 151 1

Special cleaner for the cleaning and disinfection of vehicle air conditioning systems. Removes germs, bacteria and fungus. Stops unpleasant odours and preventive effect in case of respiratory problems and allergies which may be triggered by bacteria or other micro organisms.

Disinfects, cleans, protects. Fights germs, bacteria, viruses and fungus.

Multifunctional disinfectant wipes. Suitable for plastics, textiles, painted, metallic and ceramic surfaces in vehicles, offices, EDP rooms, leisure facilities.

Direct application on the heat exchanger of the air conditioning system due to extra special long hose with special jet spray nozzle. Long-term effect due to disinfection and cleaning where the contaminations accumulate. Permeates even thick, greasy build-up of dirt due to thorough spray cleaning.

Simple and fast application, suitable with spray dispenser 0891 764 1. Contents sufficient for 16 applications.

Quick and easy. Very good compatibility with materials. Does not harm plastic materials or staining. Silicone-free.

Silicone-free. Approved by the German Society for Hygiene and Microbiology a c c o r d i n g to DGHM.

Approved by the German Society for Hygiene and Microbiology a c c o r d i n g to DGHM.

AOX free. Prevents problems with local sewerage law. Two applications per can.

QUICKFRESH 0893 764 51

2 in 1 cleaning of vehicle air conditioners. No costly dismantling work required on the evaporator and the vehicle interiors. Elimination of odours in the vehicle interiors and air conditioners. Same steps for all types of vehicles. Compact and handy. Outstanding retail article. Additional profit for workshop. Further billable unit – one can for one use. Low hazard potential in daily use. AOX and silicone free.


2008 coolius.qxd:coolius 2008.qxd

15/2/08

16:32

Page 12

Retrofit Comprehensive universal set of parts for the purpose of retrofitting existing R12 air conditioning system to the new refrigerant R134a. Adaptor 90° thread 1/4” high pressure side, RED 0764 000 145

Adaptor 90° thread 1/4” low pressure side, BLUE 0764 000 144

Special valve and ratchet wrench 0764 000 115

3/16”, 1/4”, 5/16”, 3/8”

Valve to Manufacturer 0764 000 054

Vauxhall/Opel, Volvo, BMW, Alfa Romeo, MG Rover, Audi/VW, Citroen, Ford, Fiat, Jaguar, Porsche, Mercedes, Renault, Saab

Valve Key

Valve Key II

0764 000 030

0764 000 130

Schrader valves of European or Japanese vehicles can be replaced by means of the valve key

For Eaton valves, Ford, Renault, Alfa, Peugeot

0764 000 055

Ford/Mazda, Nissan/Infinity, Land Rover, Honda, Toyota/Lexus, Geo, Subaru, Audi/VW

R134A Adaptor High to Low Side 0764 000 117

High to low side adaptor, connects to 0764 000 114 For use on Renault Lagunas or when low pressure side is difficult to reach

Halogen leak detector 0764 000 011

For detecting leaks of R134a, R12, R22 and all Halogenated refrigerants from an air conditioning system. Detection of leak is indicated by an audible alarm and visually.

Goggles 0899 102 110

Panorama field of view with all-round ventilation system and can be worn over spectacles. Impact-resistant polycarbonate lens with fogproof coating. Complies to EN 166 and EN 170.

Certified to SAEJ1627 and CE Approved. Variable frequency audible alarm with six LED visual leak indicator and high and low sensitivity levels with one touch reset. Spare sensing tip included. Cordless.


2008 coolius.qxd:coolius 2008.qxd

15/2/08

Air conditioning O-Ring assortments

16:32

Page 13

O-Rings VW/Audi

Spring lock unlocking tools for Vauxhall/Opel

Contents: 260 pieces 0964 764 030

0764 000 335

O-rings for air conditioning systems must be resistant to refrigerants, such as R134a, R12, R413. These O-rings for air conditioning systems are made from EPDM. In order to prevent mix-ups, automotive manufacturers tend to use green, purple or, in some cases, yellow, colour coded O-rings. The O-rings or sealing rings of our COOLIUS range of products are all refrigerant-resistant.

O-Rings universal

0764 000 272 0764 000 211 0764 000 042 0764 000 173 0764 000 043 0764 000 193 0764 000 044

Contents: 165 pieces 0964 764 004

0764 000 042 0764 000 043 0764 000 044 0764 000 045 0764 000 046 0764 000 047 0764 000 171 0764 000 051

x 20 x 20 x 20 x 20 x 10 x 10 x 10 x2

0764 000 056 0764 000 032 0764 000 053 0764 000 041 0764 000 048 0764 000 049 0764 000 054 0764 000 055

Especially for Vauxhall/Opel (GM) spring lock connections.

x 20 x 20 x 20 x 20 x 20 x 20 x 20

0764 000 336 0764 000 334 0764 000 045 0764 000 194 0764 000 167 0764 000 168 0764 000 166

x 20 x 10 x 20 x 20 x 10 x 20 x 20

Spring locks

Protective valve caps universal

Contents: 68 pieces 0964 764 036

Contents: 70 pieces 0964 764 034

x2 x 12 x 10 x 10 x2 x2 x 10 x5

O-Rings for Cargo/Trucks Contents: 300 pieces 0964 764 035

0764 000 329 0764 000 330 0764 000 331 0764 000 332 0764 000 318 0764 000 319

x1 x1 x1 x1 x6 x6

0764 000 320 0764 000 321 0764 000 280 0764 000 276 0764 000 283 0764 000 213

x6 x6 x 10 x6 x6 x6

Line End Plugs Contents: 79 pieces 0964 764 026

0764 000 313 0764 000 312 0764 000 311 0764 000 272 0764 000 294 0764 000 295 0764 000 277 0764 000 047 0764 000 042

x 10 x 10 x 10 x 20 x 20 x 20 x 20 x 20 x 20

0764 000 297 0764 000 046 0764 000 043 0764 000 044 0764 000 045 0764 000 185 0764 000 290 0764 000 166

x 20 x 20 x 20 x 20 x 20 x 20 x 20 x 20

0764 000 260 0764 000 261 0764 000 262 0764 000 263 0764 000 264

x 10 x 10 x 10 x 10 x 10

0764 000 265 0764 000 266 0764 000 267 0764 000 268 0764 000 269

x 10 x5 x5 x5 x5

0764 000 324 0764 000 308 0764 000 054 0764 000 304 0764 000 325 0764 000 302 0764 000 322

x5 x5 x5 x5 x5 x5 x5

0764 000 307 0764 000 323 0764 000 309 0764 000 055 0764 000 305 0764 000 306 0764 000 303

x5 x5 x5 x5 x5 x5 x5


2008 coolius.qxd:coolius 2008.qxd

15/2/08

16:32

Page 14

THE ASSEMBLY PROFESSIONALS

Air conditioning Service Check

Diagnosis

Repair

Customer information

Vehicle information

Customer No.: _____________________________________________

License plate: _____________________________________________

Address:

Make and model:

Year:

1. Customer complaint:

2. Temperature and pressure values: Outside temperature

Inside temperature before after

High pressure (bar) before after

15°C 20°C 26°C 32°C 37°C

3. Faults or defects found:

4. Leak detection additive filled in: yes

Company stamp

no

5. Leak sealant additive filled in: yes

no

6. Disinfection performed: yes Date

no Signature

Low pressure (bar) before after


2008 coolius.qxd:coolius 2008.qxd

15/2/08

16:32

Page 15

THE ASSEMBLY PROFESSIONALS

Service Record for R134a Systems Company information

Customer information

Address:

Type of equipment: ________________________________________ Month/Year: ______________________ / ______________________ Processed by: ______________________________________________

Date

License Plate

Quantity extracted

Quantity filled in

Difference

Remark

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Consumption

Checked:

Signature


2008 coolius.qxd:coolius 2008.qxd

15/2/08

16:32

Page 16

Contact Würth We operate a team of regional sales consultants covering from the north of Scotland down to the tip of Cornwall. All of our consultants are fully trained to give you the best advice and service in your field. We also have product specialists who can help with queries on any associated products. To find out more about the product range, please either contact your local sales consultant or Würth’s customer service centre on 08705 987 841 and they will be happy to answer any questions directly.

Tel. 08705 987 841 Fax. 08705 987 842 www.wurth.co.uk

© Würth UK Ltd. All rights reserved in all media. No part of this catalogue may be reproduced in any form, copied or stored electronically, whole or in part without prior written permission. Every effort has been made to verify all information. Products may vary in appearance from those pictured. The information expressed is intended as a recommendation only, based on our tests and experience. However, we cannot accept any responsibility for results in individual cases because of the wide variety of applications as well as storage and processing conditions beyond our control. This also applies when making use of our technical and commercial customer service which is supplied free of charge and without obligation. We always recommend that you carry out individual tests. We guarantee the consistent quality of our products. Subject to technical changes and developments. Würth UK Limited cannot accept responsibility for any errors or omissions or for any losses that may arise as a result.

Würth UK /pjc - 04/08 © • printer QUDDOS • run 7,0000 • 1999 02

Würth UK Limited 1 Centurion Way Erith • Kent DA18 4AE


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.