04_e_climate_control

Page 32

Buch_Kuehlgeraete.book Seite 30 Mittwoch, 18. März 2009 6:51 18

Climate control – Air conditioners Side-mounted air conditioner ACX 400 Air conditionersMain CataloguePart number in bold face type: ready for despatch within 2 working daysPart number in normal type: ready for despatch within 10 working days

Cooling capacity 400 W Compact and extremely flat construction

Delivery comprises (completely wired, ready for connection)

00901002

Item 1 2 3 4 5

Qty 1 1 1 1 1

6

1

Description Air conditioner, see technical data Cover hood, St, 1 mm, RAL 7021 Grille, St, 1 mm, silver-metallic Mains cable, length 2 m, open end Thermostat for setting of cabinet internal temperature; preset to 35 °C Assembly kit incl. drilling template and user manual

Order Information Description

21

M6

212 ,0 °ø M 9 8 7 6 5 4 3 2 1

Side-mounted air conditioner ACX 400

Input voltage V

Frequency Hz

230

50/60

Part no.

10710-100

,0 °ø M 9 8 7 6 5 4 3 2 1

147

,0 °ø M 9 8 7 6 5 4 3 2 1

92 ,0 °ø M 9 8 7 6 5 4 3 2 1

100 120

254

,0 °ø M 9 8 7 6 5 4 3 2 1

°ø M 9 8 7 6 5 4 3 2 1 ,0

,0 °ø M 9 8 7 6 5 4 3 2 1

,0 °ø M 9 8 7 6 5 4 3 2 1

20,75

,0 °ø M 9 8 7 6 5 4 3 2 1

78

,0 °ø M 9 8 7 6 5 4 3 2 1

200

,0 °ø M 9 8 7 6 5 4 3 2 1

420

,0 °ø M 9 8 7 6 5 4 3 2 1

,0 °ø M 9 8 7 6 5 4 3 2 1

600

560,5

Technical data

55 ,0 °ø M 9 8 7 6 5 4 3 2 1

11

ø 30 ,0 °ø M 9 8 7 6 5 4 3 2 1

232

,0 °ø M 9 8 7 6 5 4 3 2 1

,0 °ø M 9 8 7 6 5 4 3 2 1

KT6740

Dimensions drilling template Performance diagram W

TI °C

600

500 55

400

50 45

300

40

Voltage Frequency Usable cooling capacity at L 35 (internal temperature Ti) and L 35 (ambient temperature Ta) to DIN 3168 (EN 814 part 5) Usable cooling capacity at L 35 (Ti) and L 50 (Ta) to DIN 3168 (EN 814 part 5) Power consumption for L 35 (Ti) and L 35 (Ta) Power consumption for L 35 (Ti) and L 50 (Ta) Performance index EER at L 35 (Ti) and L 35 (Ta) (usable cooling capacity/eff. power consumption) Airflow volume internal system (measured) Nominal current max. Inrush current Temperature range Type of protection to EN 60 529 for internal system Type of protection to EN 60 529 for external circuit Duty rating Noise pressure level (LPA) Coolant Connecting type Weight Dimensions H x W x D Test certificate

230 V 50/60 Hz 400 W

275 W 260 W 310 W 1.54 265 m3/h 1.8 A 3A +20 °C...+55 °C IP 54 IP 34 100 % 52.8 dB(A) R 134a Mains cable 2 m Approx. 16 kg 600 x 254 x 120 mm CE

35 200

30

Note

25

115 VAC and special voltages available on request Microcontroller version available on request Outdoor version available on request

100 20 0 20

25

30

35

40

45

50

55 TA °C KT6741

Ta = ambient temperature, Ti = cabinet inner temperature

For further information www.schroff.biz/oneclick oneClick search code = Part no.

ServicePLUS see page 4.36

4.30

Main Catalogue E 03/2009

Part number in bold face type: ready for despatch within 2 working days Part number in normal type: ready for despatch within 10 working days