every structure has a roof.
evaluate. specify. repair.
We know roofs.
Wallace’s roof assessment and inspection team is experienced with standing seam, TPO, PVC, EPDM, ModBit, BUR and screw down metal roof systems. We have developed an assessment process that identifies when the condition of a roof justifies repair or replacement. In addition, most of our roof consultants are licensed professional engineers and can rapidly develop re-roof and structural repair drawings as required. Our mission is to extend the lifespan of your roof, specify repairs when needed and recommend replacement when necessary.
roofing and insulation types.
TPO |
Thermoplastic polyolefin
plastic + UV protectors + reinforcing fibers + olefin
PVC |
Polyvinyl Chloride
ethylene + chlorine + plasticisers
EPDM (Rubber) |
Ethylene Propylene Diene Monomer
rubber + polymer
Mod-Bit |
Modified Bitumen
asphalt (bitumen) + polymers (modifiers) + reinforcements
APP Mod-Bit (plastic) | SBS Mod-Bit (elastic)
BUR |
Built Up Roof
fiberglass + asphalt + coating
Elastomeric |
Category of elastic roof coating products
Asphalt Shingles |
Asphalt or composite shingles
fiberglass mat embedded between two asphalt layers
Metal |
Screw down, standing seam, painted, coated
EPS |
Expanded Polystyrene
styrofoam insulation
Polyiso or ISO |
Polyisocyanurate insulation
assess
damage and create solutions.
Our evaluation process includes general condition, damage, life-cycle, and installation assessments.
Our assessment scorecard is a numerical roof condition grading system saved in our database to help facility managers prioritize, schedule and budget future maintenance planning.
We are able to recommend and design repairs as well as provide re-roof design drawings along with the calculations for code and energy verifications.
| original roof type: BUR | damage: exposed scrim
| solution: verified metal deck capacity and replaced with TPO
| original roof type: PVC | damage: hail | solution: replaced with TPO
| original roof type: BUR | damage: exposed scrim, alligatoring of aging BUR and repair coating, severely corroded structural metal deck | solution: reinforced metal deck and replaced with TPO
| original roof type: Mod-Bit | damage: missing aggregate, failed sealants, seams and repairs, deteriorated membrane, alligatoring, corrosion | solution: Mod-Bit overlay
original roof type: standing seam metal | damage: corrosion | solution: flute fill, coverboard, TPO
a dynamic team.
Our
and
roof
consultant team has performed assessments
inspected millions
of
square
feet of
roofs. We’re ready to listen to what you need and help shape what you want. Let’s get started.
dan mazzei, pe, se, cwi, rro, principal
800.364.5858 • dan.mazzei@wallace.design
harry coates, rrc
800.364.5858 • harry.coates@wallace.design