PSZ-RP SERIES POWER INVERTER
71-140V
Wi-Fi
Interface Optional
Optional
Optional
Optional
Please fill out the requested information Please fill out the requested information
Optional
Type Inverter Heat Pump Indoor Unit PSA-RP71KA PSA-RP100KA PSA-RP125KA PSA-RP140KA Outdoor Unit PUHZ-ZRP71VHA2 PUHZ-ZRP100VKA3 PUHZ-ZRP100YKA3 PUHZ-ZRP125VKA3 PUHZ-ZRP125YKA3 PUHZ-ZRP140VKA3 PUHZ-ZRP140YKA3 1 Refrigerant R410A* Outdoor power supply Power Source Supply Outdoor (V/Phase/Hz) VKA • VHA:230 / Single / 50, YKA:400 / Three / 50 12.5 9.5 9.5 12.5 13.4 13.4 kW 7.1 Rated Cooling Capacity 5.5 - 14.0 4.9 - 11.4 4.9 - 11.4 5.5 - 14.0 6.2 - 15.0 6.2 - 15.0 kW 3.3 - 8.1 Min - Max 4.09 2.50 2.50 4.09 4.06 4.06 kW 1.89 Rated Total Input 3.06 – – 3.06 3.30 3.30 – EER – – – – – – – EEL Rank 12.5 9.5 9.5 12.5 13.4 13.4 kW 7.1 Design Load 847 606 595 885 872 883 kWh/a 396 Annual Electricity Consumption*2 5.0*4 5.5 5.6 4.9*4 5.3*4 5.3*4 6.3 SEER Energy Efficiency Class A A+ A++ – – – – 11.2 11.2 kW 7.6 14.0 14.0 16.0 16.0 Rated Heating Capacity (Average 4.5 - 14.0 4.5 - 14.0 kW 3.5 - 10.2 5.0 - 16.0 5.0 - 16.0 5.7 - 18.0 5.7 - 18.0 Min - Max Season) Total Input 3.08 3.08 kW 2.21 4.24 4.24 4.79 4.79 Rated – – – 3.30 3.30 3.34 3.34 COP – – – – – – – EEL Rank 7.8 7.8 kW 4.7 9.3 9.3 10.6 10.6 Design Load 7.8 (–10°C) 7.8 (–10°C) 4.7 (–10°C) 9.3 (–10°C) 9.3 (–10°C) 10.6 (–10°C) 10.6 (–10°C) Declared Capacity at reference design temperature kW 7.8 (–10°C) 7.8 (–10°C) kW 4.7 (–10°C) 9.3 (–10°C) 9.3 (–10°C) 10.6 (–10°C) 10.6 (–10°C) at bivalent temperature 5.8 (–20°C) 5.8 (–20°C) kW 3.5 (–20°C) 7.0 (–20°C) 7.0 (–20°C) 7.9 (–20°C) 7.9 (–20°C) at operation limit temperature 0 0 kW 0 0 0 0 0 Back Up Heating Capacity 2761 2761 kWh/a 1666 3285 3285 3331 3331 Annual Electricity Consumption*2 4.0 4.0 4.0 4.0*4 4.0*4 4.4*4 4.4*4 SCOP Energy Efficiency Class A+ A+ A+ – – – – 8.7 A 27.2 Operating Current (max) 19.4 27.2 10.2 28.7 13.7 0.11 kW 0.11 Indoor Input 0.06 0.11 0.11 0.11 0.11 Rated Unit 0.71 A 0.71 0.4 0.73 0.73 0.73 0.73 Operating Current (max) mm 1900 - 600 - 360 Dimensions <Panel> H × W × D 46 kg 46 46 46 46 48 48 Weight <Panel> 25 - 28 - 30 m3/min 25 - 28 - 30 20 - 22 - 24 25 - 28 - 31 25 - 28 - 31 25 - 28 - 31 25 - 28 - 31 Air Volume [Lo-Mid-Hi] 45 - 49 - 51 dB(A) 45 - 49 - 51 40 - 42 - 44 45 - 49 - 51 45 - 49 - 51 45 - 49 - 51 45 - 49 - 51 Sound Level (SPL) [Lo-Mid-Hi] 65 dB(A) 65 60 66 66 66 66 Sound Level (PWL) mm 943 - 950 - 330 (+30) Outdoor Dimensions 1338-1050-330(+40) H×W×D Unit 123 kg 116 70 116 125 118 131 Weight 110.0 m3/min 110.0 55.0 120.0 120.0 120.0 120.0 Air Volume Cooling 110.0 m3/min 110.0 55.0 120.0 120.0 120.0 120.0 Heating 49 dB(A) 49 47 50 50 50 50 Sound Level (SPL) Cooling 51 dB(A) 51 48 52 52 52 52 Heating 69 dB(A) 69 67 70 70 70 70 Sound Level (PWL) Cooling 8.0 A 26.5 19.0 26.5 9.5 28.0 13.0 Operating Current (max) 16 A 32 25 32 16 40 16 Breaker Size mm 9.52 / 15.88 Ext. 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 Diameter Liquid / Gas Piping Max. Length m 75 75 50 75 75 75 75 Out-In m 30 30 30 30 30 30 30 Max. Height Out-In °C –15 ~ +46 Guaranteed Operating Range Cooling*3 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 [Outdoor] °C –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 Heating *1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional. *2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located. *3 Optional air protection guide is required where ambient temperature is lower than –5°C. *4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.
PSZ-P SERIES
STANDARD INVERTER
Wi-Fi
Interface Optional
Optional
Optional
Optional
Optional
Please fill out the requested information Please fill out the requested information
Type Inverter Heat Pump Indoor Unit PSA-RP100KA PSA-RP100KA PSA-RP125KA PSA-RP125KA PSA-RP140KA PSA-RP140KA Outdoor Unit PUHZ-P100VHA5 PUHZ-P100YHA3 PUHZ-P125VHA4 PUHZ-P125YHA2 PUHZ-P140VHA4 PUHZ-P140YHA2 1 Refrigerant R410A* Outdoor power supply Power Source Supply Outdoor (V/Phase/Hz) VHA:230 / Single / 50, YHA:400 / Three / 50 13.6 13.6 12.3 12.3 9.4 kW 9.4 Rated Cooling Capacity 5.5 - 15.0 5.5 - 15.0 5.5 - 14.0 5.5 - 14.0 4.9 - 11.2 kW 4.9 - 11.2 Min - Max 5.640 5.640 4.380 4.380 3.120 kW 3.120 Total Input Rated 2.41 2.41 2.81 2.81 – – EER E E C C – – EEL Rank – – – – 9.4 kW 9.4 Design Load – – – – 716 kWh/a 716 Annual Electricity Consumption*2 – – – – 4.6 4.6 SEER – – Energy Efficiency Class – – B B 16.0 16.0 14.0 14.0 11.2 kW 11.2 Rated Heating Capacity (Average 5.0 - 18.0 5.0 - 18.0 5.0 - 16.0 5.0 - 16.0 4.5 - 12.5 kW 4.5 - 12.5 Min - Max Season) Total Input 5.690 5.690 4.980 4.980 3.280 kW 3.280 Rated 2.81 2.81 2.81 2.81 – – COP D D D D – – EEL Rank – – – – 8.0 kW 8.0 Design Load – – – – 6.3 (–10°C) 6.3 (–10°C) Declared Capacity at reference design temperature kW – – – – 7.1 (–7°C) kW 7.1 (–7°C) at bivalent temperature – – – – 5.0 (–15°C) kW 5.0 (–15°C) at operation limit temperature – – – – 1.7 kW 1.7 Back Up Heating Capacity – – – – 2945 kWh/a 2945 Annual Electricity Consumption*2 – – – – 3.8 3.8 SCOP – Energy Efficiency Class – – – A A 13.7 30.2 13.7 28.7 A 13.7 Operating Current (max) 28.7 0.11 0.11 0.11 0.11 kW 0.11 Indoor Input 0.11 Rated Unit 0.73 0.73 0.73 0.73 A 0.71 0.71 Operating Current (max) mm 1900 - 600 - 360 Dimensions <Panel> H × W × D 48 48 46 46 kg 46 46 Weight <Panel> 25 - 28 - 31 25 - 28 - 31 25 - 28 - 31 25 - 28 - 31 m3/min 25 - 28 - 30 25 - 28 - 30 Air Volume [Lo-Mid-Hi] 45 - 49 - 51 45 - 49 - 51 45 - 49 - 51 45 - 49 - 51 dB(A) 45 - 49 - 51 45 - 49 - 51 Sound Level (SPL) [Lo-Mid-Hi] 66 66 66 66 dB(A) 65 65 Sound Level (PWL) mm Outdoor Dimensions H×W×D 943 - 950 - 330 (+30) 1350 - 950 - 330 (+30) Unit 101 99 101 99 kg 77 75 Weight 119.0 119.0 119.0 119.0 m3/min 60.0 60.0 Air Volume Cooling 100.0 100.0 100.0 100.0 m3/min 60.0 60.0 Heating 55 55 54 54 dB(A) 50 50 Sound Level (SPL) Cooling 56 56 55 55 dB(A) 54 54 Heating 75 75 74 74 dB(A) 70 70 Sound Level (PWL) Cooling 13.0 29.5 13.0 28.0 A 13.0 28.0 Operating Current (max) 16 40 16 32 A 16 32 Breaker Size 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 mm 9.52 / 15.88 Ext. 9.52 / 15.88 9.52 / 15.88 Diameter Liquid / Gas Piping Max. Length 50 50 50 m 50 50 50 Out-In 30 30 30 m 30 30 30 Max. Height Out-In –15 ~ +46 –15 ~ +46 –15 ~ +46 °C –15 ~ +46 Guaranteed Operating Range Cooling*3 –15 ~ +46 –15 ~ +46 [Outdoor] –15 ~ +21 –15 ~ +21 –15 ~ +21 °C –15 ~ +21 –15 ~ +21 –15 ~ +21 Heating *1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional. *2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located. *3 Optional air protection guide is required where ambient temperature is lower than –5°C. *4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.
98