PEZ-RP SERIES
Optional
Wi-Fi
POWER INVERTER
Interface Optional
Optional
Optional
Type PEA-RP200GAQ
Indoor Unit Outdoor Unit
PUHZ-ZRP200YKA2
Inverter Heat Pump PEA-RP400GAQ PEA-RP250GAQ
Capacity Total Input
Outdoor power supply 400 / Three / 50
Rated Min - Max Rated
kW
19.0
22.0
38.0
44.0
kW kW
9.0 - 22.4
11.2 - 27.0
18.0 - 44.8
22.4 - 54.0
6.46
8.31
12.47
17.10
2.94
2.65
3.05
2.57
–
–
–
–
EER EEL Rank Heating Capacity (Average Season) Total Input
Rated
kW
22.4
27.0
44.8
54.0
Min - Max Rated
kW kW
9.5 - 25.0
12.5 - 31.0
18.0 - 50.0
25.0- 62.0
6.94
8.94
13.43
18.36
3.23
3.02
3.34
2.94
–
–
–
–
21.0
23.3
41.8
47.4
kW A
1.000
1.180
1.550
2.840
2.0
2.3
3.8
mm
400 - 1400 - 634
400 - 1600 - 634
kg m3/min Pa
70
77
130
133
52.0 - 65.0
64.0 - 80.0
120.0
160.0
COP EEL Rank Operating Current (max) Input [Cooling / Heating] Rated Indoor Unit Operating Current (max) Dimensions Weight
HxWxD
Air Volume [Lo-Hi] External Static Pressure Sound Level (SPL) [Lo-Hi]
dB(A) dB(A)
Sound Level (PWL) Outdoor Dimensions Unit Weight Air Volume
HxWxD
Sound Level (PWL)
150
150
150
49 - 52
52*2
53*2
76
76
72 1338 - 1050 - 330(+40)
78 1338 - 1050 - 330(+40)
kg
135
135
135
135
140
140
140
140
Heating
m /min
140
140
140
140
Cooling Heating
dB(A)
59
59
59
59
dB(A) dB(A)
62
62
62
62
77
77
77
77
A A mm
19.0
21.0
19.0
21.0
Operating Current (max) Breaker Size Liquid / Gas Out-In Out-In
Guaranteed Operating Range [Outdoo
150
m3/min 3
Cooling
Diameter Max. Length Max. Height
5.4 595 - 1947 - 764
48 - 51
mm
Cooling
Sound Level (SPL)
Ext. Piping
PUHZ-ZRP250YKA2 x 2
R410A *1
Refrigerant Source Power Supply Outdoor (V/Phase/Hz) Cooling
PEA-RP500GAQ
PUHZ-ZRP200YKA2 x 2
PUHZ-ZRP250YKA2
m m
32
32
32
32
9.52 / 25.4
12.7 / 25.4
9.52 / 25.4
12.7 / 25.4
100
100
100
100
30
30
30
30
Cooling *3
o
-15 ~ +46
-15 ~ +46
-15 ~ +46
-15 ~ +46
Heating
o
-20 ~ +21
-20 ~ +21
-20 ~ +21
-20 ~ +21
C C
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional. *2 Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located. *3 Optional air protection guide is required where ambient temperature is lower than -5°C. *4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.
PEZ-P SERIES
STANDARD INVERTER
Interface Optional
Optional
Type Indoor Unit Outdoor Unit Refrigerant Source Power Supply Outdoor (V/Phase/Hz) Cooling Capacity Rated Total Input EER Heating Capacity (Average Season) Total Input COP
Inverter Heat Pump PEA-RP400GAQ PEA-RP250GAQ
PUHZ-P200YKA2
PUHZ-P250YKA2
PEA-RP500GAQ
PUHZ-P200YKA2 x 2
PUHZ-P250YKA2 x 2
400 / Three / 50
Min - Max Rated EEL Rank Rated Min - Max Rated
Operating Current (max) Indoor Input [Cooling / Heating] Rated Unit Operating Current (max) Dimensions HxWxD Weight Air Volume [Lo-Hi] External Static Pressure Sound Level (SPL) [Lo-Mid-Hi] Sound Level (PWL)
Sound Level (SPL)
PEA-RP200GAQ
R410A *1 Outdoor power supply
kW kW kW
kW kW kW
EEL Rank
Outdoor Dimensions Unit Weight Air Volume
Optional
Optional
Wi-Fi
HxWxD Cooling Heating Cooling Heating Cooling
Sound Level (PWL) Operating Current (max) Breaker Size Ext. Diameter Liquid / Gas Piping Max. Length Out-In Max. Height Out-In Guaranteed Operating Range Cooling *3 [Outdoor] Heating
kW A mm kg m3/min Pa dB(A) dB(A) mm kg m3/min m3/min dB(A) dB(A) dB(A) A A mm m m
19.0
22.0
38.0
44.0
9.0 - 22.4
11.2 - 27.0
18.0 - 44.8
22.4 - 54.0
6.64
8.71
12.83
17.90
2.86
2.53
2.96
2.46
–
–
–
–
22.4
27.0
44.8
54.0
9.5 - 25.0
12.5 - 31.0
18.0 - 50.0
25.0- 62.0
7.10
9.31
13.75
19.10
3.15
2.90
3.26
2.83
–
–
–
–
21.0
23.3
41.8
47.4
1.000
1.180
1.550
2.840
2.0
2.3
3.8
400 - 1400 - 634
400 - 1600 - 634
5.4 595 - 1947 - 764
70
77
130
133
52.0 - 65.0
64.0 - 80.0
120.0
160.0
150
150
150
150
48 - 51
49 - 52
52*2
53*2
76
76
72 1338 - 1050 - 330(+40)
78 1338 - 1050 - 330(+40)
127
135
127
135
140
140
140
140
140
140
140
140
58
59
58
59
60
62
60
62
78
77
78
77
19.0
21.0
19.0
21.0
32
32
32
32
9.52 / 25.4
12.7 / 25.4
9.52 / 25.4
12.7 / 25.4
70
70
70
30
30
30
30
70
o
-15 ~ +46
-15 ~ +46
-15 ~ +46
-15 ~ +46
o
-20 ~ +21
-20 ~ +21
-20 ~ +21
-20 ~ +21
C C
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional. *2 Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located. *3 Optional air protection guide is required where ambient temperature is lower than -5°C. *4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.
87