PLZ-RP SERIES POWER INVERTER
Optional
Optional
Optional
60-140V/200/250
Wi-Fi
Interface
Please fill out the requested information Please fill out the requested information
Optional
Type Indoor Unit
Optional
Optional
Optional
Optional
Inverter Heat Pump PLAZP35EA PUHZZRP35VKA2
Outdoor Unit
PLAZP50EA
PLAZP60EA
PLAZP71EA
PUHZZRP50VKA2
PUHZZRP60VHA2
PUHZZRP71VHA2
PLA-ZP100EA
PLA-ZP125EA
PLA-ZP140EA
PUHZPUHZPUHZPUHZPUHZPUHZZRP100VKA3 ZRP100YKA3 ZRP125VKA3 ZRP125YKA3 ZRP140VKA3 ZRP140YKA3 R410A*1 Outdoor power supply VKA • VHA:230 / Single / 50, YKA:400 / Three / 50 6.1 12.5 12.5 13.4 13.4 5.0 7.1 9.5 9.5 3.6 2.7 - 6.5 5.5 - 14.0 5.5 - 14.0 6.2 - 15.0 6.2 - 15.0 2.3 - 5.6 3.3 - 8.1 4.9 - 11.4 4.9 - 11.4 1.6 - 4.5 1.66 3.84 3.84 4.36 4.36 1.33 1.79 2.20 2.20 0.78 – 3.25 3.25 3.07 3.07 – – – – – – – – – – – – – – – 6.1 12.5 12.5 13.4 13.4 5.0 7.1 9.5 9.5 3.6 318 650 661 732 743 253 336 461 472 170 6.7 6.7*4 6.6*4 6.4*4 6.3*4 6.9 7.4 7.2 7.0 7.4 A++ A++ A++ A++ A++ A++ – – – – 7.0 6.0 8.0 11.2 11.2 4.1 14.0 14.0 16.0 16.0 2.8 - 8.2 2.5 - 7.3 3.5 - 10.2 4.5 - 14.0 4.5 - 14.0 1.6 - 5.2 5.0 - 16.0 5.0 - 16.0 5.7 - 18.0 5.7 - 18.0 1.89 1.55 1.90 2.60 2.60 0.85 3.67 3.67 4.84 4.84 – – – – – – 3.81 3.81 3.30 3.30 – – – – – – – – – – 4.4 3.8 4.7 7.8 7.8 2.5 9.3 9.3 10.6 10.6 4.4 (–10°C) 3.8 (–10°C) 4.7 (–10°C) 7.8 (–10°C) 7.8 (–10°C) 2.5 (–10°C) 9.3 (–10°C) 9.3 (–10°C) 10.6 (–10°C) 10.6 (–10°C) 4.4 (–10°C) 3.8 (–10°C) 4.7 (–10°C) 7.8 (–10°C) 7.8 (–10°C) 2.5 (–10°C) 9.3 (–10°C) 9.3 (–10°C) 10.6 (–10°C) 10.6 (–10°C) 2.8 (–20°C) 3.7 (–11°C) 3.5 (–20°C) 5.8 (–20°C) 5.8 (–20°C) 2.1 (–11°C) 7.0 (–20°C) 7.0 (–20°C) 7.9 (–20°C) 7.9 (–20°C) 0 0 0 0 0 0 0 0 0 0 1337 1109 1342 2229 2229 714 2768 2768 3297 3297 4.6 4.8 4.9 4.9 4.9 4.9 4.7*4 4.7*4 4.5*4 4.5*4 A++ A++ A++ A++ A++ A++ – – – – 19.2 13.2 19.3 27.0 8.5 13.2 27.0 10.0 28.7 13.7 0.03 0.03 0.05 0.07 0.07 0.03 0.08 0.08 0.10 0.10 0.22 0.22 0.34 0.47 0.47 0.21 0.52 0.52 0.66 0.66 258 - 840 - 840 <40 - 950 - 950> 298 - 840 - 840 <40 - 950 - 950> 21 <5> 24 <5> 26 <5> 26 <5> 27 <5> 27 <5> 27 <5> 27 <5> 11 - 13 - 15 - 16 12 - 14 - 16 - 18 12 - 14 - 16 - 18 17 - 19 - 21 - 23 19 - 22 - 25 - 28 19 - 22 - 25 - 28 21 - 24 - 26 - 29 21 - 24 - 26 - 29 24 - 26 - 29 - 32 24 - 26 - 29 - 32 26- 28 - 29 - 31 27- 29 - 31 - 32 27- 29 - 31 - 32 28 - 30 - 33- 36 31 - 34 - 37 - 40 31 - 34 - 37 - 40 33 - 36 - 39 - 41 33 - 36 - 39 - 41 36 - 39 - 42 - 44 36 - 39 - 42 - 44 54 54 57 61 61 51 62 62 65 65 630 - 809 - 300 943 - 950 - 330 (+30) 1338 - 1050 - 330 (+40) 70 46 70 116 123 43 116 125 118 131 55 45 55 110 110 45 120 120 120 120 55 45 55 110 110 45 120 120 120 120 47 44 47 49 49 44 50 50 50 50 48 46 48 51 51 46 52 52 52 52 67 65 67 69 69 65 70 70 70 70 19.0 13.0 19.0 26.5 8.0 13.0 26.5 9.5 28.0 13.0 25 16 25 32 16 16 32 16 40 16 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 6.35 / 12.7 6.35 / 12.7 50 50 50 75 75 50 75 75 75 75 30 30 30 30 30 30 30 30 30 30 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –20 ~ +21 –11 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –11 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21
Refrigerant Power Source Supply Outdoor (V/Phase/Hz) kW Rated Cooling Capacity kW Min - Max kW Total Input Rated EER EEL Rank kW Design Load kWh/a Annual Electricity Consumption*2 SEER Energy Efficiency Class kW Rated Heating Capacity (Average kW Min - Max Season) Total Input kW Rated COP EEL Rank kW Design Load Declared Capacity at reference design temperature kW kW at bivalent temperature kW at operation limit temperature kW Back Up Heating Capacity kWh/a Annual Electricity Consumption*2 SCOP Energy Efficiency Class A Operating Current (max) kW Indoor Input Rated Unit A Operating Current (max) mm Dimensions <Panel> H × W × D kg Weight <Panel> m3/min Air Volume [Lo-Mi2-Mi1-Hi] dB(A) Sound Level (SPL) [Lo-Mi2-Mi1-Hi] dB(A) Sound Level (PWL) mm Outdoor Dimensions H×W×D Unit kg Weight m3/min Air Volume Cooling m3/min Heating dB(A) Sound Level (SPL) Cooling dB(A) Heating dB(A) Sound Level (PWL) Cooling A Operating Current (max) A Breaker Size mm Ext. Diameter Liquid / Gas Piping Max. Length m Out-In m Max. Height Out-In °C Guaranteed Operating Range Cooling*3 [Outdoor] °C Heating *1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional. *2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located. *3 Optional air protection guide is required where ambient temperature is lower than –5°C. *4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.
PLZ-P SPLZ-PSERIES SERIES STANDARD INVERTER
PUHZ
Optional
Optional
PUHZ
PUHZ
Optional PUHZ
SUZ
PUHZ
PUHZ
PUHZ
Wi-Fi
Interface
Please fill out the requested information Please fill out the requested information
Optional
Type Indoor Unit Outdoor Unit
81
Optional
Optional
Optional
Optional
Optional
Inverter Heat Pump PLARP35EA SUZKA35VA6
PLARP50EA
PLARP60EA
PLARP71EA
SUZKA50VA6
SUZKA60VA6
SUZKA71VA6
PLA-RP100EA
PLA-RP125EA
PLA-RP140EA
PUHZPUHZPUHZPUHZPUHZPUHZP100VHA5 P100YHA3 P125VHA4 P125YHA2 P140VHA4 P140YHA2 1 R410A* Outdoor power supply VA • VHA:230 / Single / 50, YHA:400 / Three / 50 13.6 13.6 12.3 5.7 12.3 5.5 7.1 9.4 9.4 3.6 5.5 - 15.0 5.5 - 15.0 5.5 - 14.0 2.3 - 6.3 5.5 - 14.0 2.3 - 5.6 2.8 - 8.1 4.9 - 11.2 4.9 - 11.2 1.4 - 3.9 5.21 5.21 4.08 1.76 4.08 1.61 2.10 3.48 3.48 1.02 2.61 2.61 3.01 – 3.01 – – – – – D D B – B – – – – – – – – 5.7 – 5.5 7.1 9.4 9.4 3.6 – – – 307 – 295 400 584 584 181 – – – 6.5 – 6.5 6.2 5.6 5.6 6.9 – – – A++ – A++ A++ A+ A+ A++ 16.0 16.0 14.0 6.9 14.0 5.8 8.0 11.2 11.2 4.1 5.0 - 18.0 5.0 - 18.0 5.0 - 16.0 2.5 - 8.0 5.0 - 16.0 1.7 - 7.2 2.6 - 10.2 4.5 - 12.5 4.5 - 12.5 1.7 - 5.0 4.98 4.98 4.10 1.97 4.10 1.69 2.24 3.28 3.28 1.00 3.21 3.21 3.41 – 3.41 – – – – – C C B – B – – – – – – – – 4.6 – 4.3 5.8 8.0 8.0 2.6 – – – 4.0 (–10°C) – 3.8 (–10°C) 4.7 (–10°C) 6.3 (–10°C) 6.3 (–10°C) 2.3 (–10°C) – – – 4.1 (–7°C) – 3.8 (–7°C) 5.1 (–7°C) 7.0 (–7°C) 7.0 (–7°C) 2.3 (–7°C) – – – 4.0 (–10°C) – 3.8 (–10°C) 4.7 (–10°C) 5.0 (–15°C) 5.0 (–15°C) 2.3 (–10°C) – – – 0.6 – 0.5 1.1 1.7 1.7 0.3 – – – 1498 – 1505 1888 2717 2717 826 – – – 4.3 – 4.0 4.3 4.1 4.1 4.4 – – – A+ – A+ A+ A+ A+ A+ 13.7 30.2 13.7 14.2 28.7 12.2 16.4 28.5 13.5 8.4 0.10 0.10 0.10 0.03 0.10 0.03 0.04 0.07 0.07 0.03 0.66 0.66 0.66 0.24 0.66 0.22 0.27 0.46 0.46 0.20 258 - 840 - 840 <40 - 950 - 950> 298 - 840 - 840 <40 - 950 - 950> 26 <5> 26 <5> 26 <5> 21 <5> 26 <5> 19 <5> 21 <5> 24 <5> 24 <5> 19 <5> 11 - 13- 15- 16 12 - 14 - 16 - 18 12 - 14 - 16 - 18 14 - 17- 19- 21 19- 23 - 26 - 29 19- 23 - 26 - 29 21- 25 - 28 - 31 21- 25 - 28 - 31 24 - 26 - 29 - 32 24 - 26 - 29 - 32 26- 28 - 29 - 31 27- 29 - 31 - 32 27- 29 - 31 - 32 28 - 30 - 32 - 34 31- 34 - 37 - 40 31- 34 - 37 - 40 33- 37- 41- 44 33- 37- 41- 44 36 - 39 - 42 - 44 36 - 39 - 42 - 44 65 65 65 54 65 54 56 61 61 51 550 - 800 - 285 880 - 840 - 330 943 - 950 - 330 (+30) 1350 - 950 - 330 (+30) 101 99 101 50 99 54 53 75 77 35 119 119 119 40.9 119 44.6 50.1 60 60 36.3 100 100 100 49.2 100 44.6 48.2 60 60 34.8 55 55 54 55 54 52 55 50 50 49 56 56 55 55 55 52 55 54 54 50 75 75 74 65 74 65 69 70 70 62 13.0 29.5 13.0 14.0 28.0 12.0 16.1 28.0 13.0 8.2 16 40 16 20 32 20 20 32 16 10 6.35 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 6.35 / 12.7 6.35 / 9.52 50 50 50 30 50 30 30 50 50 20 30 30 30 30 30 30 30 30 30 12 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –10 ~ +46 –15 ~ +21 –15 ~ +21 –15 ~ +21 –10 ~ +24 –15 ~ +21 –10 ~ +24 –10 ~ +24 –15 ~ +21 –15 ~ +21 –10 ~ +24
Refrigerant Power Source Supply Outdoor (V/Phase/Hz) kW Rated Cooling Capacity kW Min - Max kW Total Input Rated EER EEL Rank kW Design Load kWh/a Annual Electricity Consumption*2 SEER Energy Efficiency Class kW Rated Heating Capacity (Average kW Min - Max Season) Total Input kW Rated COP EEL Rank kW Design Load Declared Capacity at reference design temperature kW kW at bivalent temperature kW at operation limit temperature kW Back Up Heating Capacity kWh/a Annual Electricity Consumption*2 SCOP Energy Efficiency Class A Operating Current (max) kW Indoor Input Rated Unit A Operating Current (max) mm Dimensions <Panel> H × W × D kg Weight <Panel> m3/min Air Volume [Lo-Mi2-Mi1-Hi] dB(A) Sound Level (SPL) [Lo-Mi2-Mi1-Hi] dB(A) Sound Level (PWL) mm Outdoor Dimensions H×W×D Unit kg Weight m3/min Air Volume Cooling m3/min Heating dB(A) Sound Level (SPL) Cooling dB(A) Heating dB(A) Sound Level (PWL) Cooling A Operating Current (max) A Breaker Size mm Ext. Diameter Liquid / Gas Piping Max. Length m Out-In m Max. Height Out-In °C Guaranteed Operating Range Cooling*3 [Outdoor] °C Heating *1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional. *2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located. *3 Optional air protection guide is required where ambient temperature is lower than –5°C. *4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.