PUMY SERIES PUMY-P112/125/140VKM3(-BS) PUMY-P112/125/140YKM3(-BS)
Unit : mm
PUMY-P200YKM1(-BS) OUTDOOR UNIT
OUTDOOR UNIT
2-U Shaped notched holes (Foundation Bolt M10)
Rear Air Intake 600 Installation Feet
225
600
225
Installation Feet
Side Air Intake
Air Discharge
For the transmission line
Terminal connection From left to right
1050
362 For the branch box power supply
For the power supply
42 60 2-12×36 Oval holes (Foundation Bolt M10)
Air Discharge
Terminal connection From left to right
1050 Ground for the power supply ("GR"marking position)
For the power supply
For concentration control
986 393 451
1338
632
160
160
Refrigerant GAS pipe connection (FLARE) ø15.88 (5/8F) Refrigerant LIQUID pipe connection (FLARE) ø9.52 (3/8F) • • • Indication of STOP VALVE connection location. •••
2 *1
136
Bottom piping hole (Knock-Out)
45
Drain hole (5-ø33)
•••
Model
A
PUMY-P112/125/140VKM3(-BS)
1078
PUMY-P112/125/140YKM3(-BS)
909
PAC-MK52BC
110 160
160
160
Drain hole (5-ø33)
Example of Notes 1
2 *1
••• ••• •••
Refrigerant GAS pipe connection (FLARE) ø19.05 (3/4F) Refrigerant LIQUID pipe connection (FLARE) ø9.52 (3/8F) Indication of STOP VALVE connection location.
PAC-MK32BC
Suspension bolt: W3/W8 (M10)
Suspension bolt: W3/W8 (M10)
Branch box
Branch box Suspension bolt pitch 320
24
24
402 Suspension bolt pitch
402 Suspension bolt pitch
Suspension bolt pitch 320
12
Terminal block to outdoor unit
A
25 25 70 70
Service panel (for lev. thermistor)
Suspension bolt : W3/8(M10)
Refrigerant pipe flared connection To outdoor unit A B C D E Liquid pipe 1/4F 1/4F 1/4F 1/4F 1/4F 3/8F Gas pipe 3/8F 3/8F 3/8F 3/8F 1/2F 5/8F
149
40
Control cover Bush To outdoor unit Service panel (for lev. thermistor)
Suspension bolt : W3/8(M10)
Refrigerant pipe flared connection A B C Liquid pipe 1/4F 1/4F 1/4F Gas pipe 3/8F 3/8F 3/8F
Terminal block to M-net unit
5-electric wire inlet
112
170 65 47
170 65 47
Cap 25
B
87
280 70
A
B
C C
96 83
Terminal block to indoor unit
TB2B
Control cover Bush To outdoor unit
TB3E
25 25 25 25 70 70 70 70
90 72
TB3C
A
To indoor unit
TB3B
A
450
TB5
B
209 Cap
TB3A
B
TB3D
C
Terminal block to indoor unit TB3B
C
70
Terminal block to M-net unit 5-electric wire inlet
TB2B
D
87
40
TB3C
D
83
280
TB5
25
E
72
96
12
TB3A
E
90
112
450 To indoor unit
67
Front piping cover Rear piping cover
86
154
86
154 136 110 160
Example of Notes 1
81
Rear piping cover
Bottom piping hole (Knock-Out)
45
Air Intake
26
*1 426 483
Air Intake
26
369
Handle for moving
Front piping cover
81
For concentration control
Service panel
369
A
632
1338
Service panel Handle for moving
2
For the transmission line
Ground for the branch box power supply
Ground for the branch box power supply
1
For the branch box power supply
Ground for the power supply Ground for the transmission line Ground for concentration control
Ground for the transmission line Ground for concentration control
Handle for moving
56 33 0 53
28
25
42 56 2-12×36 Oval holes (Foundation Bolt M10)
70
362
56 33 0 53
28
25
330
370 417
Side Air Intake
370 417
330
19
225
225
2-U Shaped notched holes (Foundation Bolt M10)
19
Rear Air Intake
To outdoor unit 3/8F 5/8F
Terminal block to outdoor unit