PLZ-SHW SERIES
Please fill out the requested information Please fill out the requested information
Indoor Unit
Remote Controller
Outdoor Unit
PLA-ZP100/125EA
Panel
PUHZ-SHW112VHA(-BS) PUHZ-SHW112/140YHA(-BS)
Enclosed in PLP-6EALM/PLP-6EALME
With Wireless With Auto With Signal With 3D i-see Remote Controller Elevation Sensor Receiver
Panel PLP-6EA PLP-6EAL PLP-6EAE PLP-6EALE PLP-6EAJ PLP-6EAJE PLP-6EALM PLP-6EALME
Optional
*optional
Optional
*optional
Optional
100/125
Wi-Fi
Interface Optional
Optional
Optional
Optional
Optional
Type Indoor Unit
Inverter Heat Pump PLA-ZP100EA
Outdoor Unit
PUHZ-SHW112VHA
Refrigerant Source Power Supply Outdoor (V/Phase/Hz) Cooling
Capacity Total Input EER
kW
Min - Max
kW
Rated
kW
EEL Rank kW
Annual Electricity Consumption*2
kWh/a
SEER Energy Efficiency Class Heating Capacity (Average Season) Total Input
kW kW
4.5 - 14.0 2.667 –
4.5 - 14.0 2.667 –
kW
– 12.7 11.2 (-10°C)
– 12.7 11.2 (-10°C)
11.2 (-7°C) 9.3 (-25°C) 1.5
11.2 (-7°C) 9.3 (-25°C) 1.5
4420 4.0 A+
4420 4.0 A+
35.5 0.07 0.47
13.5 0.07 0.47 298 - 840 - 840 <40- 950 - 950>
26 <5> 19 - 22 - 25 - 28
26 <5> 19 - 22 - 25 - 28
31 - 34 - 37 - 40 61
31 - 34 - 37 - 40 61 1350 - 950 - 330 (+30) 134 100 100
at reference design temperature
kW
at bivalent temperature
kW
Annual Electricity Consumption*2
kW kW kWh/a
SCOP Energy Efficiency Class Operating Current (max)
A
Input
Rated Operating Current (max)
kW
Dimensions <Panel> H × W × D Weight <Panel>
mm kg m3/min
Sound Level (SPL) [Lo-Mi2-Mi1-Hi]
dB(A)
Sound Level (PWL)
dB(A) H×W×D
mm kg m /min
Heating
m /min
120 100 100
Cooling
dB(A)
51
51
Heating
dB(A)
Cooling Operating Current (max)
dB(A)
52 69
52 69
A
35
13
A mm
40 9.52 / 15.88
16 9.52 / 15.88
m
75
75
m C
30 –15 ~ +46 –25 ~ +21
30 –15 ~ +46 –25 ~ +21
Sound Level (SPL)
Cooling
Sound Level (PWL) Breaker Size Diameter
Liquid / Gas
Max. Length
Out-In
Max. Height Guaranteed Operating Range [Outdoor]
117
A
Air Volume [Lo-Mi2-Mi1-Hi]
Air Volume
Ext. Piping
12.5 5.5 - 14.0 5.000 2.50 – 12.5 856 5.1*4
Rated
at operation limit temperature Back Up Heating Capacity
Outdoor Dimensions Unit Weight
400 / 3 / 50
10.0 4.9 - 11.4 2.857 – – 10.0 633 5.5 A 11.2
Min - Max
EEL Rank
Indoor Unit
400 / 3 / 50
10.0 4.9 - 11.4 2.857 – – 10.0 633 5.5 A 11.2
kW
COP
Declared Capacity
230 / 1 / 50
Rated
Design Load
Out-In Cooling*3 Heating
PUHZ-SHW140YHA
R410A*1 Outdoor power supply
Rated
Design Load
PLA-ZP125EA PUHZ-SHW112YHA
3 3
o o
C
– 14.0 5.0 - 16.0 4.000 3.50 – 15.8 14.0 (-10°C) 14.0 (-7°C) 9.5 (-25°C) 1.8 6213 3.5*4 – 13.5 0.08 0.52 26 <5> 21 - 24 - 26 - 29 33 - 36 - 39 - 41 62 134 100 100 51 52 69 13 16 9.52 / 15.88 75 30 –15 ~ +46 –25 ~ +21
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional. *2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located. *3 Optional air protection guide is required where ambient temperature is lower than –5°C. *4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.