Specifications

FHYC (Ceiling Mounted Cassette Type) <60Hz> - Twin Model

Indoor Unit Outdoor Unit

∗1 Cooling Capacity (1)/(2)/(3)

kW Btu/h kcal/h

Indoor Unit ∗2 Dimensions H×W×D Coil Type Row×Stages×Fin Pitch Face Area Fan Model Type Motor Output Air Flow Rate Sound Pressure Level Weight Piping Liquid Connections Gas Drain Remote Controller Wired (Option) Wireless Decoration Model Panel Color (Option) ∗2 Dimensions (H×W×D) Air Filter Weight Outdoor Unit Color Dimensions Coil

Comp.

Fan

Weight Piping Connections

H×W×D Type Row×Stages×Fin Pitch Face Area Model Type Motor Output Model Type Motor Output Air Flow Rate Liquid Gas Drain

Safety Devices Capacity Step Refrigerant Control Ref. Piping Max. Length Max. Height Difference Refrigerant Model Charge (Factory Charge) Ref. Oil Model Charge Drawing No.

Notes:

FHYC71KVE×2 R140LUTAL R140LUYAL 16.1/15.8/– 55,000/53,900/– 13,800/13,500/– FHYC71KVE×2 230×840×840 Cross Fin Coil 2×8×1.5 0.331 QTS45B14M

TAL YAL

mm

FHYC100KVE×2 R200KUTAL R200KUYAL 22.5/22.2/20.0 76,800/75,800/68,300 19,400/19,100/17,200 FHYC100KVE×2

FHYC125KVE×2 R250KUTAL R250KUYAL 27.1/26.6/24.1 92,500/90,800/82,300 23,300/22,900/20,700 FHYC125KVE×2

2

288×840×840 Cross Fin Coil (Waffle Louver Fins and Hi–XA Tubes) 2×12×1.5 m² 0.497 QTS45A17M Turbo Fan W 45 90 m³/min. (H)19 (L)14 (H)28 (L)21 (H)33 (L)24 dB(A) (H)35 (L)30 (H)39 (L)34 (H)42 (L)36 kg 24 28 mm φ9.5 (Flare) mm φ15.9(Flare) φ19.1(Flare) mm I.Dφ25×O.Dφ32 BRC1C61 (Note. 4) BRC7C613W BYC125K–W1×2 White mm 40×950×950 Resin Net (with Mold Resistant) kg 5 R140LUTAL R200KUTAL R250KUTAL TAL R140LUYAL R200KUYAL R250KUYAL YAL Ivory mm 1,345×900×320 1,220×1,280×690 1,440×1,280×690 Cross Fin Coil (Waffle Louver Fins and Hi–XA Tubes) 2×60×2.0 2×40×2.0 2×50×2.0 m² 1.134 1.57 1.97 JT212D–P1 JT300D–P1 JT170BC TAL JT212D–P1YH JT300D–P1YH JT170BC–YH YAL Hermetically Sealed Scroll Type kW 4.50 5.5 7.5 P47L11S×2 P52H11SM Propeller W 100+75 230+190 m³/min. 101 160 190 kg 109 177 200 mm φ9.5 (Flare) φ12.7 (Flare) φ15.9 (Flare) mm φ19.1 (Flare) φ25.4 (Flange) φ28.6 (Flange) mm φ26.0 (Hole) — Thermal Protector for Outdoor Fan Motor and Indoor Fan Motor. High Pressure Switch. Low Pressure Switch. Over Current Device. Reverse Phase Protector. Fuse. % 100–0 Electronic Expansion Valve Capillary Tube m 50 (Equivalent Length 70m) m 30 R22 kg 4.1 (Charged for 30m) 5.3 (Charged for 5m) 5.7 (Charged for 5m) SUNISO 4GSDID–K L 1.6 3.0 4D039109 4D029964 4D029966

1. ∗1 The above data based on the conditions shown in the table below.

Conversion Formulae

Mark

Cooling

Piping length

Standard

Model

(1)

Indoor : 27°CDB, 19.5°CWB Outdoor : 35°CDB, 24°CWB

5m

LU, KU

(2)

Indoor : 27°CDB, 19.0°CWB Outdoor : 35°CDB, 24°CWB

5m

KU

7.5m

JIS B8616

LU

(3)

Indoor : 29°CDB, 19.0°CWB Outdoor : 46°CDB, 24°CWB

7.5m

SSA 385/386

KU

kcal/h=kW×860 Btu/h=kW×3414 cfm=m³/min×35.3

2. Capacities are net, including a deduction for cooling for indoor fan motor heat. 3. ∗2 Each value for indoor unit shows the specification per one unit. 4. Wire for remote controller : Field supplied.