11.2 Thermostat T-55 alarms/problems

UK English

An alarm is sent when more than 3 hours have elapsed since the controller received the last radio signal from the thermostat. The table below lists problems that can occur in Thermostat T-55. Indication

Causes

Solutions

LED flashes twice

Thermostat battery power is running low

Replace batteries

11.3 Thermostat T-54 Public alarms/problems An alarm is sent when more than 3 hours have elapsed since the controller received the last radio signal from the thermostat. The table below shows problems that can occur in Thermostat T-54 Public. Indication

Causes

Solutions

Power LED and channel LED flashes

Cover of thermostat is opened

Check thermostat settings and replace thermostat cover

LED flashes twice

Thermostat battery power is running low

Replace the batteries

11.4 Controller C-55/56 alarms/problems An alarm is sent when more than 3 hours have elapsed since the controller received the last radio signal from the thermostat. The table below shows problems that can occur in the Controller C-55/56. Indication

Causes

Solutions

Power LED and channel LEDs in the Controller C-55/56 flash

Antenna out of position or wire disconnected

Install antenna in correct position with wire correctly connected

Alarm in Interface I-75/76

Batteries in thermostat are discharged

Replace batteries When error is resolved, thermostat screen displays room temperature and battery icon is replaced with

Battery icon displayed in room information on Interface I-75/76 Radio alarm in Interface I-75/76

Thermostat is out of correct position

Radio icon in room information on Interface I-75/76

Reduce distance between thermostat and Controller C-55/56 or change location of thermostat in the room

Power LED and thermostat LED's in the Controller C-55/56 for connected channels flash

11.5 Contact installer For installer contact information, see the installation report in the fold-out of this document. Prepare the following information before contacting an installer: •

Installation report

Drawings of the underfloor heating system (if available)

List of all alarms, including time and date

U P O N O R C O N T R O L S Y S T E M – I N S TA L L AT I O N A N D O P E R AT I O N M A N U A L