Siemens

Page 366

© Siemens AG 2011

Technical Information Shutter/Blind Controls sys shutter/blind control inserts (5TC1 231)

■ Schematics Example 2: Group control with 2 motors and central operating point

Sample connection

M 1~

AC 230 V ~

230 V AC ~

PE N L

PE N L

4

1 N

1 2

6

L IN

M

5

N

5TC1 231

L IN

4

3

M

5TC1 231

7 4

I2_08611

M 1 2 3 4 5 6 7

Neutral conductor Secondary input UP Secondary input DOWN Motor UP Motor DOWN External conductor connection Interface (230-V-PEI)

2

N

L IN

M

5TC1 231

5 M

Application options

3

Example 1: Shutter/blind control with conventional extension units

L

N IN

M

5TC1 231

5TA2 114 I2_08613

L

1

2

M 1~

230 V ~ AC PE N L

N

L IN

M

5TC1 231

I2_08612a

When using the shutter/blind pushbutton (5TA2 114), the shutter/blind can be manually moved to the required position (UP/DOWN or STEP command). The number of connectable conventional extension units is unlimited.

Together with the UP 211 wave shutter/blind pushbutton inserts, the sys shutter/blind control insert $ is implemented as a central operating point. The inserts % and & individually control the respective shutter/blind motors M (( and )). The time values stored in the UP 211 wave shutter/blind pushbutton (e.g. 8:00 UP and 20:00 DOWN command) allow the timecontrolled stopping and starting of all connected motors. Caution: • It is not permissible to use a shutter/blind control sys insert as the central operating point and directly operate a shutter/blind motor. • When protecting the central operating point against short circuit using a separate residual current operated circuit breaker, both circuits must be isolated in order to prevent inadvertent tripping of the circuit breaker. Example 3: Integrating a wind alarm The indicator for the wind alarm is integrated in the shutter/blind control over the extension unit input. In the event of a wind alarm, the shutters/blinds are raised and locked in that position until the wind alarm is reset over the indicator. As long as the interlock is enabled, neither manual nor automatic operation of the shutters/ blinds is possible.

19 19/52

Siemens ET D1 · 10/2010