Experimental Determination of Optimum Refrigerant Insulation Combination in a VCR System using Tagu

Page 1

International Journal of Mechanical and Production Engineering Research and Development (IJMPERD) ISSN (P): 2249-6890; ISSN (E): 2249-8001 Vol. 9, Issue 3, Jun 2019, 439-452 Š TJPRC Pvt. Ltd.

EXPERIMENTAL DETERMINATION OF OPTIMUM REFRIGERANT INSULATION COMBINATION IN A VCR SYSTEM USING TAGUCHI METHOD ANUSHA PEYYALA1 & NVVS SUDHEER2 1

Department of Mechanical Engineering, V P Siddhartha Institute of Technology, Vijayawada, Andhra Pradesh, India 2

Department of Mechanical Engineering, R V R & J C College of Engineering, Guntur, Andhra Pradesh, India

ABSTRACT Various studies have been done to investigate the effect of various parameters on the performance of the vapour compression system. In the vapour compression refrigeration cycle, external parameters such as refrigerants and Insulation materials have a higher effect on the performance of vapor compression refrigeration system. For the purpose

method to find out the possible combinations that are formed. In the present study, Using Taguchi L16 orthogonal array considering the two deign parameters viz. Type of Refrigerant and Type of Insulation experiments were conducted and were analyzed. Analysis of variance (ANOVA) was carried out to obtain the significant values of the Coefficient of performance and Work required for the compressor at 95 % confidence level. From ANOVA it can be concluded that the Insulation (X) and Refrigerant (Y) both are significant for COP and Wc. Percentage contribution of input parameters was also calculated. For COP experiment the percentage contribution of Insulation (X) is equal to 95.85% and Refrigerant (Y)

Original Article

of finding the best combination, we have selected the Taguchi method. Minitab software helped us to apply the Taguchi

is equal to 3.87%. For Wc experiment, the percentage contribution of Insulation (X) is equal to 77.58% and Refrigerant (Y) is equal to 19.46%. KEYWORDS: ANOVA, COP, Insulation, Refrigerant, Taguchi & VCRS

Received: Mar 01, 2019; Accepted: Mar 21, 2019; Published: Apr 24, 2019; Paper Id.: IJMPERDJUN201947

1. INTRODUCTION As we know, Refrigeration is the science of producing and maintaining temperatures below that of the surrounding atmosphere. The performance of a system is depended on so many factors out of the two main factors are working substance refrigerants and the insulations of gas and liquid pipelines in a VCR system. So many authors have worked on this area of interest like in 2005, Ahmet Z. Sahin, et al [1], explained regarding Optimum insulation thickness of a circular duct subjected to external radiative heat transfer for a given quantity of insulation material. A circular duct through that fluid is transported from one finish to the opposites taken into account. The thickness of the insulation is assumed to be linearly variable since this is often straight forward to implement in observe. Thus, the slope of the insulation thickness is taken into account because of the parameter for optimum insulation. Variations of the majority temperature of the fluid furthermore because the temperature of the outer surface of the insulation area unit evaluated.