SCPP-school-investigation-post-remediation

Page 4

Right Elevation 1-Before Remediation

Grid Location

Item Description

Moisture Readings

4E-I

Roof

N/A

5/6 F/G Moisture 30-40% N/A

N/A

N/A

5F

Flashing

N/A

Detail Photo

Observations

EPDM roof material delaminating on seam joints at flashing intersections creating entry points for water ingress. Red shaded area indicates 40% moisture content on 9.5-9.6 floor inside door under carpet and 30% on door header Metal panel vertical overlap seams loose in numerous 1.2, 1.6 locations where water can breach building envelope 1.1, 2.4, Metal "head flashing" design inverted and holding 2.6 water above doors 4.2-4.6