Vega Controls - Dectectors

Page 1

Radiation-based

Detectors

Overview

Page 214

FIBERTRAC

Page 216

SOLITRAC

Page 218

MINITRAC

Page 220

POINTRAC

Page 222

WEIGHTRAC

Page 224

213


FIBERTRAC, SOLITRAC, MINITRAC, POINTRAC, WEIGHTRAC Radiation-based sensors for level, density and mass flow measurement Measuring principle In the radiation-based measurement, a Caesium 137 or Cobalt 60 isotope emits focused gamma rays. A special sensor located at the opposite side of the vessel receives this radiation. The so called scintillator converts the gamma rays into signals, their number is detected and processed. Because gamma rays are damped when penetrating the substance, the sensor can calculate the level, the limit level, the density or the mass flow out of the received radiation.

Applications Level measurement With FIBERTRAC and SOLITRAC level changes are contactlessly measured through the vessel wall. Since the measuring facility is mounted on the outside of the vessel, the measurement is insensitive to extreme process conditions. Also measurements on pressurized vessels or on vessels with agitators can be simply realized. For round vessel forms the flexible FIBERTRAC is recommended, which can be simply mounted on the vessel. A high reliability can be reached with SOLITRAC on cylindrical vessels. The sensors are cascadable for very large measuring ranges.

Density measurement The non-contact, continuous density and concentration measurement of liquids and bulk solids with MINITRAC is suitable for pipelines and vessels. The measuring principle is independent of aggressive products and ensures a high reliablity. The sensor mounting is carried out on existing pipelines. With small tube diameters an inclined radiation or the use of a measuring track is recommended. In case there is also a temperature sensor connected, then MINITRAC takes the heat expansion of the medium into account. Furthermore the mass flow of MINITRAC can be calculated with the signal of a flow volume measuring instrument. This ensures reliable measurement results and permanent process continuity even with extreme process conditions.

Flow measurement The WEIGHTRAC determines contactlessly the exact delivery volume of solids. Through the frame construction, the sensor can be simply mounted to the conveyor belt. The measurement runs wear and maintenance-free. A simple and reliable adjustment of the sensor saves time during setup. The WEIGHTRAC is suitable for conveyor systems, for example conveyor belt weighers, screw conveyors, chain trough conveyors, steel plate conveyors, bucket conveyors.

214

Radiation-based – PROTRAC


Instrument type

Version

Measuring range

Process fitting

Reproducibility

FIBERTRAC 31

Sensor with flexible plastic detector ø 42 mm

up to 7 m

From outside on the vessel

± 0.5 %

SOLITRAC 31

Sensor with PVT rod detector

up to 3 m

From outside on the vessel

± 0.5 %

MINITRAC 31

Sensor with integrated NaI detector

---

From outside on the vessel or on pipelines

± 0.1 %

POINTRAC 31

Sensor with PVT rod detector

up to 305 mm

From outside on the vessel or on pipelines

---

WEIGHTRAC 31

Sensor with PVT rod detector

up to 1600 mm

Through supplied measuring frame

± 1 % of measuring range final value

Radiation-based – PROTRAC

Radiation-based

Overview

215


FIBERTRAC 31 Radiation-based sensor for continuous level and interface measurement Application area The FIBERTRAC 31 is a radiation-based sensor for continuous measurement of liquids and bulk solids. It is suitable for level and interface measurement under extreme process conditions, in aggressive products or critical product features. The FIBERTRAC 31 delivers precise measuring results even under hardest application conditions. Your benefit  High plant availability through non-contact measurement  Simple mounting on round and conical vessels through flexible detector  Cost saving through use of only one sensor up to 7 m measuring range Technical data Version: Measuring range: Mounting: Reproducibility: SIL qualification:

61,4 mm (2.42")

111,5 mm (4.39")

L Measuring length

291 mm (11.46")

180 mm (7.09")

ø 85,7 mm (3.37")

sensor with flexible plastic detector ø 42 mm up to 7 m from outside on the vessel +/- 0.5 % optionally up to SIL2

50 mm (1.97")

L

143,6 mm (5.65")

ø 42 mm (1.58")

You will find further process fittings and options under www.vega.com/configurator. You will find further drawings and tables under www.vega.com/downloads. You will find mounting accessory, welded sockets and housing overviews in chapter "Accessory".

216

Radiation-based – FIBERTRAC 31


Radiation-based

Approval XX Without .............................................................................................................................................................................................................. DK ATEX II 2G Ex d ia IIC T6+1D,2D Ex tD IP66 T ............................................................................................................................................... TX ATEX IM 2 (M1) Ex d [ia Ma] I Mb .................................................................................................................................................................... DK IEC Zone 1 Ex d ia IIC T6+Ex tD A20,A21 IP66 T ............................................................................................................................................ TX IEC Ex d [ia Ma]I Mb ......................................................................................................................................................................................... Version / Ambient temperature 1 Standard / -20º...+50ºC ................................................................................................................................................................................ Electronics V Four-wire 4...20mA/HART® .................................................................................................................................................................. S Four-wire 4...20mA/HART® with SIL qualification ................................................................................................................................ A Four-wire 4...20 mA/HART® (Explosion Proof Output) ......................................................................................................................... I Four-wire 4...20 mA/HART® (Explosion Proof Output) SIL .................................................................................................................. L Four-wire 4...20 mA/HART® (Intrinsic. Safe Output) SIL ...................................................................................................................... F Four-wire Foundation Fieldbus .............................................................................................................................................................. C Four-wire Foundation Fieldbus (Explosion Proof Output) ..................................................................................................................... P Four-wire Profibus PA ........................................................................................................................................................................... E Four-wire Profibus PA (Explosion Proof Output) .................................................................................................................................. Housing / Protection D Aluminum / IP66/IP67 .................................................................................................................................................................... W 316L SS / IP66/IP67 ....................................................................................................................................................................... Cable entry / Cable gland / Plug connection M M20x1.5 / with / without ........................................................................................................................................................... N 1/2 NPT / without / without ...................................................................................................................................................... Indicating / Adjustment module (PLICSCOM) X Without .............................................................................................................................................................................. B Side mounted with backlight ............................................................................................................................................. Additional equipment X without ......................................................................................................................................................................... Active length A10 1000 mm ........................................................................................................................................................... A15 1500 mm ........................................................................................................................................................... A20 2000 mm ........................................................................................................................................................... A25 2500 mm ........................................................................................................................................................... A30 3000 mm ........................................................................................................................................................... A35 3500 mm ........................................................................................................................................................... A40 4000 mm ........................................................................................................................................................... A45 4500 mm ........................................................................................................................................................... A50 5000 mm ........................................................................................................................................................... A55 5500 mm ........................................................................................................................................................... A60 6000 mm ........................................................................................................................................................... A65 6500 mm ........................................................................................................................................................... A70 7000 mm ........................................................................................................................................................... FT31.

Radiation-based – FIBERTRAC 31

217


SOLITRAC 31 Radiation-based sensor for continuous level and interface measurement Application area The SOLITRAC 31 is a radiation-based sensor with PVT rod detector for continuous measurement of liquids and bulk solids. It is suitable for level and interface measurement under extreme process conditions, with critical product features or in aggressive products. The SOLITRAC 31 is ideal for use in cylindircal vessels, reactors, autoclaves, separators and mixing vessels. Your benefit  High plant availability through non-contact measurement  Best measurement performance through PVT detector with maximum sensitivity  Simple mounting through supplied accessory Technical data Version: Measuring range: Mounting: Reproducibility: SIL qualification:

61,4 mm (2.42")

111,5 mm (4.39")

L Measuring length

256 mm (10.08")

180 mm (7.09")

ø 85,7 mm (3.37")

sensor with PVT rod detector up to 3 m from outside on the vessel +/- 0.5 % optionally up to SIL2

143,6 mm (5.65")

36 mm (1.42")

L

ø 76,2 mm (3")

You will find further process fittings and options under www.vega.com/configurator. You will find further drawings and tables under www.vega.com/downloads. You will find mounting accessory, welded sockets and housing overviews in chapter "Accessory".

218

Radiation-based – SOLITRAC 31


Radiation-based

Approval XX Without .............................................................................................................................................................................................................. DK ATEX II 2G Ex d ia IIC T6+1D,2D Ex tD IP66 T ............................................................................................................................................... TX ATEX IM 2 (M1) Ex d [ia Ma] I Mb .................................................................................................................................................................... DK IEC Zone 1 Ex d ia IIC T6+Ex tD A20,A21 IP66 T ........................................................................................................................................... TX IEC Ex d [ia Ma]I Mb ......................................................................................................................................................................................... Version / Ambient temperature 1 Standard / -40º...+60ºC ............................................................................................................................................................................... Electronics V Four-wire 4...20mA/HART® .................................................................................................................................................................. S Four-wire 4...20mA/HART® with SIL qualification ................................................................................................................................ A Four-wire 4...20 mA/HART® (Explosion Proof Output) ........................................................................................................................ I Four-wire 4...20 mA/HART® (Explosion Proof Output) SIL .................................................................................................................. L Four-wire 4...20 mA/HART® (Intrinsic. Safe Output) SIL ..................................................................................................................... F Four-wire Foundation Fieldbus ............................................................................................................................................................. C Four-wire Foundation Fieldbus (Explosion Proof Output) ..................................................................................................................... P Four-wire Profibus PA ........................................................................................................................................................................... E Four-wire Profibus PA (Explosion Proof Output) .................................................................................................................................. Housing / Protection D Aluminum / IP66/IP67 .................................................................................................................................................................... W 316L SS / IP66/IP67 ...................................................................................................................................................................... Cable entry / Cable gland / Plug connection M M20x1.5 / with / without .......................................................................................................................................................... N 1/2 NPT / without / without ...................................................................................................................................................... Indicating / Adjustment module (PLICSCOM) X Without .............................................................................................................................................................................. B Side mounted with backlight ............................................................................................................................................. Additional equipment X without ......................................................................................................................................................................... Length A05 500 mm ............................................................................................................................................................ A10 1000 mm .......................................................................................................................................................... A15 1500 mm .......................................................................................................................................................... A20 2000 mm .......................................................................................................................................................... A25 2500 mm .......................................................................................................................................................... A30 3000 mm .......................................................................................................................................................... ST31.

Radiation-based – SOLITRAC 31

219


MINITRAC 31 Radiation-based sensor for density measurement Application area The MINITRAC 31 is a radiation-based sensor for non-contact density measurement of liquids and bulk solids. The MINITRAC 31 determines the density contactlessly from outside through pipelines or the vessel wall. Through its compact design it is ideal for mounting in positions hardly to access and in narrow space applications. Your benefit  Simple retrofitting during production processes  High plant availability through non-contact measurement  Exact measuring results independent of the process conditions Technical data Version: Mounting: Reproducibility: SIL qualification:

61,4 mm (2.42")

111,5 mm (4.39")

291 mm (11.46")

180 mm (7.09")

ø 85,7 mm (3.37")

sensor with integrated NaI detector from outside on pipelines or the vessel +/- 0.1 % optionally up to SIL2

143,6 mm (5.65")

You will find further process fittings and options under www.vega.com/configurator. You will find further drawings and tables under www.vega.com/downloads. You will find mounting accessory, welded sockets and housing overviews in chapter "Accessory".

220

Radiation-based – MINITRAC 31


Radiation-based

Approval XX Without ............................................................................................................................................................................................................. DK ATEX II 2G Ex d ia IIC T6+1D,2D Ex tD IP66 T .............................................................................................................................................. TX ATEX IM 2 (M1) Ex d [ia Ma] I Mb ................................................................................................................................................................... DK IEC Zone 1 Ex d ia IIC T6+Ex tD A20,A21 IP66 T .......................................................................................................................................... TX IEC Ex d [ia Ma]I Mb ........................................................................................................................................................................................ Version / Ambient temperature 1 Standard / -40º...+60ºC .............................................................................................................................................................................. Electronics V Four-wire 4...20mA/HART® ................................................................................................................................................................. S Four-wire 4...20mA/HART® with SIL qualification ............................................................................................................................... A Four-wire 4...20 mA/HART® (Explosion Proof Output) ....................................................................................................................... I Four-wire 4...20 mA/HART® (Explosion Proof Output) SIL ................................................................................................................. L Four-wire 4...20 mA/HART® (Intrinsic. Safe Output) SIL .................................................................................................................... F Four-wire Foundation Fieldbus ............................................................................................................................................................ C Four-wire Foundation Fieldbus (Explosion Proof Output) .................................................................................................................... P Four-wire Profibus PA .......................................................................................................................................................................... E Four-wire Profibus PA (Explosion Proof Output) ................................................................................................................................. Housing / Protection D Aluminum / IP66/IP67 ................................................................................................................................................................... W 316L SS / IP66/IP67 ..................................................................................................................................................................... Cable entry / Cable gland / Plug connection M M20x1.5 / with / without ......................................................................................................................................................... N 1/2 NPT / without / without ..................................................................................................................................................... Indicating / Adjustment module (PLICSCOM) X Without ............................................................................................................................................................................ B Side mounted with backlight ............................................................................................................................................ Additional equipment X without ....................................................................................................................................................................... S Int. lead coating to protect against ambient radiation ................................................................................................ MT31.

Radiation-based – MINITRAC 31

221


POINTRAC 31 Radiation-based sensor for level detection Application area The POINTRAC 31 is a radiation-based sensor for universal level detection of liquids and bulk solids. Independent of the mounting location, it monitors reliably the limit level in vessels. The sensor can be used for applications in all industries. Due to the high sensitivity POINTRAC 31 is an economical solution with minimum radiation activity. Your benefit  Exact measuring results independent of process conditions  High process reliability through determination of buildup  Economical level detection under arduous application conditions Technical data Version: Measuring range: Mounting: SIL qualification:

61,4 mm (2.42")

111,5 mm (4.39")

256 mm (10.08")

180 mm (7.09")

ø 85,7 mm (3.37")

sensor with PVT rod detector up to 305 mm from outside on the pipeline or vessel optionally up to SIL2

ø 76,2 mm (3")

36 mm (1.42")

L

143,6 mm (5.65")

You will find further process fittings and options under www.vega.com/configurator. You will find further drawings and tables under www.vega.com/downloads. You will find mounting accessory, welded sockets and housing overviews in chapter "Accessory".

222

Radiation-based – POINTRAC 31


Radiation-based

Approval XX Without .............................................................................................................................................................................................................. DK ATEX II 2G Ex d ia IIC T6+1D,2D Ex tD IP66 T ............................................................................................................................................... TX ATEX IM 2 (M1) Ex d [ia Ma] I Mb .................................................................................................................................................................... DK IEC Zone 1 Ex d ia IIC T6+Ex tD A20,A21 IP66 T ........................................................................................................................................... TX IEC Ex d [ia Ma]I Mb ......................................................................................................................................................................................... Version / Ambient temperature 1 Standard / -40º...+60ºC ............................................................................................................................................................................... Electronics V Four-wire 8/16 mA/HART® ................................................................................................................................................................... S Four-wire 8/16 mA/HART® with SIL qualification ................................................................................................................................. A Four-wire 8/16 mA/HART® (Ex d output) ............................................................................................................................................. I Four-wire 8/16 mA/HART® (Ex d output) w. SIL qualif. ........................................................................................................................ L Four-wire 8/16 mA/HART®(Ex ia output) w. SIL qualif. ........................................................................................................................ F Four-wire Foundation Fieldbus ............................................................................................................................................................. C 4-wire Foundation Fieldbus (Explosion Proof Output) .......................................................................................................................... P Four-wire Profibus PA ........................................................................................................................................................................... E 4-wire Profibus PA (Explosion Proof Output) ........................................................................................................................................ Housing / Protection D Aluminum / IP66/IP67 .................................................................................................................................................................... W 316L SS / IP66/IP67 ...................................................................................................................................................................... Cable entry / Cable gland / Plug connection M M20x1.5 / with / without .......................................................................................................................................................... N 1/2 NPT / without / without ...................................................................................................................................................... Indicating / Adjustment Module (PLICSCOM) X Without .............................................................................................................................................................................. B Side mounted with backlight ............................................................................................................................................. Additional equipment X without ......................................................................................................................................................................... Length 006 152 mm ............................................................................................................................................................. 012 305 mm ............................................................................................................................................................. PT31.

Radiation-based – POINTRAC 31

223


WEIGHTRAC 31 Radiation-based sensor for mass flow determination Application area The WEIGHTRAC 31 is a radiation-based sensor for precise flow measurement of bulk solids. It is ideal for mass flow determination on conveyor belts and in conveyor spirals in all industries. Due to its frame construction, the WEIGHTRAC 31 can be simply retrofitted on the conveyor belt. Your benefit  Wear-free, because non-contact measurement  Exact determination of the delivery volume through simple setup Technical data Version: Measurement width: Mounting: Accuracy:

sensor with PVT rod detector up to 1600 mm through the supplied measurement frame +/- 1 % of the measuring range final value

B 30 mm (1.81")

30 mm (1.81")

70 mm (2.76")

122 mm (4.80")

136 mm (5.35")

E

D

A

Note: Source container not in the scope of delivery

C

70 mm (2.76")

You will find further process fittings and options under www.vega.com/configurator. You will find further drawings and tables under www.vega.com/downloads. You will find mounting accessory, welded sockets and housing overviews in chapter "Accessory".

224

Radiation-based – WEIGHTRAC 31


Radiation-based

Approval XX Without ............................................................................................................................................................................................................. DK ATEX II 2G Ex d ia IIC T6+1D,2D Ex tD IP66 T .............................................................................................................................................. TX ATEX IM 2 (M1) Ex d [ia Ma] I Mb ................................................................................................................................................................... DK IEC Zone 1 Ex d ia IIC T6+Ex tD A20,A21 IP66 T .......................................................................................................................................... TX IEC Ex d [ia Ma]I Mb ........................................................................................................................................................................................ Version / Ambient temperature 1 Standard / -40º...+60ºC .............................................................................................................................................................................. Electronics V Four-wire 4...20mA/HART® ................................................................................................................................................................. A Four-wire 4...20 mA/HART® (Explosion Proof Output) ....................................................................................................................... F Four-wire Foundation Fieldbus ............................................................................................................................................................ C Four-wire Foundation Fieldbus (Explosion Proof Output) .................................................................................................................... P Four-wire Profibus PA .......................................................................................................................................................................... E Four-wire Profibus PA (Explosion Proof Output) ................................................................................................................................. Housing / Protection D Aluminum / IP66/IP67 ................................................................................................................................................................... W 316L SS / IP66/IP67 ..................................................................................................................................................................... Cable entry / Cable gland / Plug connection M M20x1.5 / with / without ......................................................................................................................................................... N 1/2 NPT / without / without ..................................................................................................................................................... Indicating / Adjustment module (PLICSCOM) X Without ............................................................................................................................................................................ B Side mounted with backlight ............................................................................................................................................ Additional equipment X without ....................................................................................................................................................................... Frame construction A LCS w/Epoxy Powder Coating ............................................................................................................................ C 316L SS ............................................................................................................................................................... Conveyor width (A) N1 500 mm ....................................................................................................................................................... P1 800 mm ....................................................................................................................................................... Q1 1000 mm ..................................................................................................................................................... R1 1200 mm ..................................................................................................................................................... S1 1600 mm ..................................................................................................................................................... Source holder configuration B Single SHLD-1 mounting plate .............................................................................................................. D Dual SHLD-1 mounting plates .............................................................................................................. WT31.

Radiation-based – WEIGHTRAC 31

225


226

Radiation-based