Delta Lighting, Fire & Safety Catalogue 2022

Page 1

Lighting, Fire & Safety | Product Catalogue 2022

Lighting, Fire & Safety Product Catalogue 2022

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Lighting, Fire & Safety Welcome to the first edition of our new catalogue, combining our long established commercial lighting and site electrics brands, Brackenheath and Briticent, with Channel, the supplier of choice for emergency lighting, fire detection and security systems. Our newly created and specialist Lighting, Fire & Safety division offers an extensive range of cutting edge products, providing a 'one stop shop' for residential and commercial projects. Our dedicated sales and customer support team are on hand to provide their expertise in specifying solutions to all your lighting, fire and safety needs. Valued Customers Providing best-in-class service to our valued customers remains a key priority. With all Lighting, Fire & Safety brands now supported by one team, we are pleased to be able to offer our customers a streamlined experience, from sales, customer service and technical support to distribution. Brands You Can Rely On Quality is at the heart of everything we do and represents a core value; from development, testing and manufacture, to warehousing, logistics and customer service. Continuous investment in innovation and product design, quality assurance and ease of installation are a key focus in the development of products across all brands. Our Vision With an extensive and evolving portfolio of brands and products available within our Lighting, Fire & Safety and Core Electrical divisions, Deta Electrical continues to meet the ever-changing needs of the market and build upon its vision to become the electrical supplier of choice.

2

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Contents Brackenheath Briticent Channel Index

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

4 68 114 284

|

w: deta.co.uk

3


Established in 1978, Brackenheath has built a reputation for supplying a high quality range of domestic and commercial lighting products at competitive prices. Through continuous investment in new technology, research and development, Brackenheath pioneered the design of its market leading range of iSpot® driverless LED Floodlights and continues to lead the way in bringing to market new and innovative LED lighting solutions. Following the acquisition of Brackenheath in 2008, Deta is proud to offer an extended range of high quality and reliable lighting products to its wholesale partners.

4

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Contents iSpot® Frameless LED Floodlights REX Slim LED Floodlights CCT3 LED Floodlights with Plug-in PIR Exterior Lighting Accessories LED Dualbays® LED Panels LED Weatherproofs Exterior Wall Lights LED Bulkheads LED Cornlamps LED Batten Fittings LED Under Cabinet Lighting IP65 Integrated LED Fire Rated Downlights

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

6 - 11 12 - 19 20 - 23 24 - 27 28 - 31 32 - 37 38 - 43 44 - 47 48 - 53 54 - 57 58 - 63 64 - 65 66 - 67

|

w: deta.co.uk

5


iSpot® Frameless LED Floodlights Brackenheath’s iSpot® Frameless LED Floodlight range uses driverless technology to maintain an ultra-thin, sleek appearance. The frameless design incorporates a condensation release valve, reducing the potential for water ingress or dust build-up on the lens. A unique angled bracket allows the unit to be fully rotational, whilst the PIR (with manual override feature) can be moved both up and down and sideways, providing a range of different mounting options.

6

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Swivel mounting bracket allows the unit to be employed in a range of positions

High quality aluminium and toughened glass Driver on board technology provides sleek appearance

Supplied with 500mm pre-flexed cable designed to go through cavity walls

Frameless lens design reduces the potential for water ingress or dust build-up

Unique extra long angled bracket allows both the standard and PIR units to be fully rotational

IP65 PIR with manual override feature

Fully adjustable PIR – movement sideways and up and down for security “blind spot” applications

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

7


iSpot® Frameless

ENERGY SAVING

I2012B

iSpot® Frameless I2012B I2012W

10W 4000K IP65 - black 10W 4000K IP65 - white

I2022B I2022W

20W 4000K IP65 - black 20W 4000K IP65 - white

I2032B I2032W

30W 4000K IP65 - black 30W 4000K IP65 - white

I2042B I2042W

50W 4000K IP65 - black 50W 4000K IP65 - white

Product Code

I2012B

Finish

Black

• • • •

I2012W

I2022B

White

Black

I2022W

I2032B

White

Black

I2032W

I2042B

White

Black

I2042W White

Wattage

10W

20W

30W

50W

Lumens

900 Lm

1,800 Lm

2,700 Lm

4,500 Lm

Impact Rating

IK07

IP Rating

IP65

Colour Temperature

4000K

Voltage

220-240V (50-60Hz)

Beam Angle

110°

Rated Life (Hours)

30,000

Halogen Replacement

8

Ideal for residential applications including domestic gardens and driveways Condensation release valve allows continuous ventilation to the floodlight IP65 rating for total protection against dust and low pressure jets of water Angled bracket for easy installation Supplied with 0.5m of power flex Available in either black or white

t: 0845 884 7000

100W

|

e: sales.lfs@deta.co.uk

200W

|

w: deta.co.uk

300W

500W

IP65


ENERGY SAVING

IP65

iSpot® LED iSpot LED Floodlights Floodlights

iSpot® Frameless with PIR

9

I2013B

iSpot® Frameless with PIR I2013B I2013W

10W 4000K IP65 - black 10W 4000K IP65 - white

I2023B I2023W

20W 4000K IP65 - black 20W 4000K IP65 - white

I2033B I2033W

30W 4000K IP65 - black 30W 4000K IP65 - white

I2043B I2043W

50W 4000K IP65 - black 50W 4000K IP65 - white

Product Code

I2013B

Finish

Black

• • • • • • • •

I2013W

I2023B

White

Black

Ideal for residential applications including domestic gardens and driveways Condensation release valve allows continuous ventilation to the floodlight IP65 rating for total protection against dust and low pressure jets of water PIR with manual override PIR adjustable settings: lux, time and sensitivity PIR detection range of up to 10 metres Angled bracket for easy installation Supplied with 0.5m of power flex Available in either black or white

I2023W

I2033B

White

Black

I2033W

I2043B

White

Black

I2043W White

Wattage

10W

20W

30W

50W

Lumens

900 Lm

1,800 Lm

2,700 Lm

4,500 Lm

Impact Rating

IK07

IP Rating

IP65

Colour Temperature

4000K

Voltage

220-240V (50-60Hz)

Beam Angle

110°

Rated Life (Hours)

30,000

Halogen Replacement

100W

200W

t: 0845 884 7000

300W

|

500W

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

9


iSpot® Frameless CCT3

ENERGY SAVING

IP65

I2014B

iSpot® Frameless CCT3 Dimmable I2014B I2024B I2034B I2044B

• •

10W CCT3 IP65 - black 20W CCT3 IP65 - black 30W CCT3 IP65 - black 50W CCT3 IP65 - black

• • • • • •

Product Code

I2014B

I2024B

Wattage

10W

20W

30W

50W

Lumens

900 Lm

1,800 Lm

2,700 Lm

4,500 Lm

Finish

I2034B

Impact Rating

IK07

IP Rating

IP65

Colour Temperature

3000K/4000K/5000K

Voltage

220-240V (50-60Hz)

Beam Angle

110°

Rated Life (Hours)

30,000

t: 0845 884 7000

I2044B

Black

Halogen Replacement

10

Condensation release valve allows continuous ventilation to the floodlight Supplied with 0.5m of power flex and remote control Wattage stays consistent regardless of colour temperature change IP65 rating for total protection against dust and low pressure jets of water Single remote can control multiple fittings Dimmable by remote control Remote control covers 10 metre range Angled bracket for easy installation 90 Lm/W at 4000K, 81 Lm/W at 5000K, 76 Lm/W at 3000K

100W

|

e: sales.lfs@deta.co.uk

200W

|

w: deta.co.uk

300W

500W


ENERGY SAVING

IP65

iSpot®LED iSpot LEDFloodlights Floodlights

iSpot® Frameless CCT3 with PIR

11

I2015B

iSpot® Frameless CCT3 Dimmable with PIR I2015B I2025B I2035B I2045B

• •

10W CCT3 IP65 - black 20W CCT3 IP65 - black 30W CCT3 IP65 - black 50W CCT3 IP65 - black

• • • • • • • • • •

Product Code

Condensation release valve allows continuous ventilation to the floodlight Supplied with 0.5m of power flex Wattage stays consistent regardless of colour temperature change IP65 rating for total protection against dust and low pressure jets of water Single remote can control multiple fittings Dimmable by remote control Remote control covers 10 metre range Angled bracket for easy installation 90 Lm/W at 4000K, 81 Lm/W at 5000K, 76 Lm/W at 3000K PIR adjustable settings: lux, time and sensitivity PIR with manual override PIR detection range of up to 10 metres IP65 PIR

I2015B

I2025B

Wattage

10W

20W

30W

50W

Lumens

900 Lm

1,800 Lm

2,700 Lm

4,500 Lm

Finish

I2035B Black

Impact Rating

IK07

IP Rating

IP65

Colour Temperature

3000K/4000K/5000K

Voltage

220-240V (50-60Hz)

Beam Angle

110°

Rated Life (Hours)

30,000

Halogen Replacement

I2045B

100W

200W

t: 0845 884 7000

300W

|

500W

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

11


LED Floodlights Brackenheath’s REX Slim LED Floodlights offers installers a complete range from 10W to 300W models. Driver on board technology, combined with a high-quality aluminium casing and a toughened glass lens, ensures a sleek yet durable design. A heavy duty, swivel mounting bracket allows the unit to be installed in a range of positions. The range offers a number of different solutions for residential, commercial and industrial applications, including a PIR option (with manual override feature) in 10W to 100W models, a Photocell option in 70W to 300W models, a new Dual Voltage Asymmetrical option (100V to 240V) in 50W to 200W models and a new Coastal option in 10W to 100W models. Briticent 110V REX Slim LED Floodlights are also available, please see pages 76 to 78.

12

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


High quality aluminium body and toughened glass Driver on board technology provides sleek appearance Swivel mounting bracket allows the unit to be installed in a range of positions

Fully adjustable PIR – movement sideways and up and down for security “blind spot” applications

Unique extra long angled bracket allows both the standard and PIR units to be fully rotational

IP65 PIR with manual override feature

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

13


REX Slim

ENERGY SAVING

N6320

N6075

REX Slim N6310 N6320 N6330 N6340 N6045 N6055 N6065 N6075 N6085

Product Code

10W 4000K IP65 20W 4000K IP65 30W 4000K IP65 50W 4000K IP65 70W 4000K IP65 100W 4000K IP65 150W 4000K IP65 200W 4000K IP65 300W 4000K IP65

N6310

• • •

N6320

N6330

N6340

Ideal for residential applications including domestic gardens and driveways IP65 rating for total protection against dust and low pressure jets of water Angled bracket for easy installation 10W to 50W floodlights supplied with 0.5m of power flex 70W to 300W floodlights supplied with 1.5m of power flex

N6045

Finish

N6065

N6075

N6085

Wattage

10W

20W

30W

50W

70W

100W

150W

200W

300W

Lumens

900 Lm

1,800 Lm

2,700 Lm

4,500 Lm

6,300 Lm

9,000 Lm

13,500 Lm

18,000 Lm

27,000 Lm

450W

700W

Impact Rating

IK07

IK08

IP Rating

IP65

Colour Temperature

4000K

Voltage

220-240V (50-60Hz)

Beam Angle

115°

Rated Life (Hours)

30,000

Halogen Replacement

10W

HID Replacement

14

N6055

Black

t: 0845 884 7000

20W

30W

50W

N/A

|

e: sales.lfs@deta.co.uk

N/A 150W

|

w: deta.co.uk

250W

300W

IP65


ENERGY SAVING

IP65

REX LED LED Floodlights Floodlights REX

REX Slim with PIR

15

N6321

REX Slim with PIR

N6311 N6321 N6331 N6341 N6047 N6057

Product Code

10W 4000K IP65 20W 4000K IP65 30W 4000K IP65 50W 4000K IP65 70W 4000K IP65 100W 4000K IP65

N6311

• • • • • •

N6321

N6331

Finish

N6341

Ideal for residential applications such as domestic gardens and driveways IP65 rating for total protection against dust and low pressure jets of water PIR with manual override PIR adjustable settings: lux, time and sensitivity PIR detection range of up to 10 metres Angled bracket for easy installation 10W to 50W floodlights supplied with 0.5m of power flex 70W and 100W floodlights supplied with 1.5m of power flex

N6047

N6057

Black

Wattage

10W

20W

30W

50W

70W

100W

Lumens

900 Lm

1,800 Lm

2,700 Lm

4,500 Lm

6,300 Lm

9,000 Lm

Impact Rating

IK07

IK08

IP Rating

IP65

Colour Temperature

4000K

Voltage

220-240V (50-60Hz)

Beam Angle

115°

Rated Life (Hours)

30,000

Halogen Replacement HID Replacement

100W

200W

300W N/A

500W

N/A 150W

250W

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

15


REX Slim Photocell

ENERGY SAVING

N6046

REX Slim with Photocell N6046 N6056 N6066 N6086

70W 4000K IP65 100W 4000K IP65 150W 4000K IP65 300W 4000K IP65

• • • •

Product Code

N6046

N6056

Finish

N6086

Black

Wattage

70W

100W

150W

300W

Lumens

6,300 Lm

9,000 Lm

13,500 Lm

27,000 Lm

Impact Rating

IK08

IP Rating

IP65

Colour Temperature

4000K

Voltage

220-240V (50-60Hz)

Beam Angle

115°

Rated Life (Hours)

30,000

Replacement HID Wattages

16

N6066

Ideal for industrial and commercial applications such as factories and warehouses Photocell feature is preset to 10~20Lx On (Dusk); 30~60Lx Off (Dawn) Driver on board technology IP65 rating for total protection against dust and low pressure jets of water Angled bracket for easy installation Supplied with 1.5m of power flex

t: 0845 884 7000

150W

|

250W

e: sales.lfs@deta.co.uk

300W

|

700W

w: deta.co.uk

IP65


ENERGY SAVING

IP65

REX LED Floodlights

REX Slim Asymmetrical

17

REX Slim Asymmetrical BR3101 BR3102 BR3103 BR3104 BR3105

50W Asymmetrical Floodlight 100-240V 70W Asymmetrical Floodlight 100-240V 100W Asymmetrical Floodlight 100-240V 150W Asymmetrical Floodlight 100-240V 200W Asymmetrical Floodlight 100-240V

• • • •

Asymmetrical floodlight offers exceptional quality of anti-glare light and improved light utilisation Wide voltage range driver (100-240V) allows for single installation for both temporary 110V site power and 240V permanent installations High quality black aluminium body with toughened glass lens Extra-long angled mounting bracket, allowing the unit to be fully rotational Complete with 1.5m of power flex (50W version 0.5m) IP65 rating for total protection from dust and low-pressure jets of water from any direction

Product Code

BR3101

BR3102

BR3103

BR3104

Wattage

50W

70W

100W

150W

200W

Lumens

6,000 Lm

8,400 Lm

12,000 Lm

18,000 Lm

24,000 Lm

IP Rating

IP65

Colour Temperature

4000K

Beam Angle

80*145°

Voltage

100V-240V (50-60Hz)

Rated Life (Hours)

50,000

BR3105

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

17


REX Slim Coastal

18

ENERGY SAVING

REX Slim Coastal

BR3121 BR3122 BR3123 BR3124 BR3125

10W LED Coastal Floodlight 20W LED Coastal Floodlight 30W LED Coastal Floodlight 50W LED Coastal Floodlight 100W LED Coastal Floodlight

• • • •

High quality graphene floodlight, designed to withstand coastal environments, salt laden locations and extreme wet conditions Housing corrosion resistance, salt spray >10,000 hrs, UV resistant (UL 746c-f1) IP65 Rating for total protection against dust and low-pressure jets of water Supplied with 0.5m power flex (100W 1.5m) 120 Lm/W Anti-rusting bracket

Product Code

BR3121

BR3122

BR3123

BR3124

Wattage

10W

20W

30W

50W

100W

Lumens

1,200 Lm

2,200 Lm

3,600 Lm

5,000 Lm

12,000 Lm

IP Rating

IP65

Colour Temperature

4000K

Beam Angle

120°

Voltage

100V-240V (50-60Hz)

Rated Life (Hours)

50,000

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

BR3125

IP65


REX LED Floodlights 19

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

19


CCT3 LED Floodlights with Plug-in PIR Brackenheath's CCT3 LED Floodlights with Plug-in PIR is suitable for a number of residential and commercial applications. Available in 10-50W models, offering CCT3 switching (3000K/4000K/5000K) and a push fit terminals, the range offers flexibility and is ideal for retrofit applications. An optional plug-in, IP65 rated PIR accessory completes the range, allowing simple conversion of the standard fitting.

20

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


High quality aluminium and toughened glass Driver on board technology provides sleek appearance Swivel mounting bracket allows the unit to be employed in a range of positions

Unique extra long angled bracket allows both the standard and PIR units to be fully rotational

Fully adjustable PIR – movement sideways and up and down for security “blind spot” applications

IP65 PIR with manual override feature

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

21


CCT3 Floodlight with Plug-in PIR

BR3020

Push fit terminal

All in one LED floodlight Ideal for retrofit and new installations Push fit terminals requires no tools for electrical connection CCT3 manual switch on rear of fitting allows switching between three colour temperatures (3000K/4000K/5000K) • 10W, 20W, 30W, 50W options • 90 Lm/W ±10%, CRI≥80 • Unique Plug-in IP65 PIR sold separately • PIR with fully adjustable pan and tilt, manual override feature, 10m detection range, 160° beam angle, adjustable lux, time and zssiiisensitivity settings

10W CCT3 IP65 20W CCT3 IP65 30W CCT3 IP65 50W CCT3 IP65 Plug-in PIR IP65

Product Code

BR3010

BR3020

BR3030

BR3050

BR3001

Wattage

10W

20W

30W

50W

N/A

Lumens

900 Lm

1,800 Lm

2,700 Lm

4,500 Lm

N/A

Impact Rating

IK06

IP Rating

IP65

Colour Temperature

3000K/4000K/5000K

Voltage

120°

Rated Life (Hours)

22

t: 0845 884 7000

N/A

220-240V (50-60Hz)

Beam Angle

160° 25,000

|

IP65

BR3001

• • • •

CCT3 Floodlight with Plug-in PIR BR3010 BR3020 BR3030 BR3050 BR3001

ENERGY SAVING

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


CCT3 Floodlights 23

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

23


Exterior Lighting Accessories Brackenheath's Exterior Lighting Accessories complement Brackenheath's comprehensive range of lighting.

24

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


t: 01582 544 | | e: sales.lfs@deta.co.uk e: sales@deta.co.uk t: 0845 884544 7000

||

w: deta.co.uk

25


Photocells • • • • • •

ENERGY SAVING

Ideal for both residential and commercial applications Compatible with all Brackenheath LED Floodlights Electronic detector for dusk/dawn switching Suitable for use within a luminaire 230V / 50Hz UV stabilised cover

PS41

N2011

PS41R

N2012

Miniature Photocells PS41 PS41R N2011 N2012

Miniature photocell 20mm Two part photocell 20mm Miniature photocell 16mm Two part photocell 16mm

Product Code

PS41

PS41R

N2011

N2012

Switching Capacity

2 x 250W Max Inductive 250W Max Fluorescent

2 x 250W Max Inductive 250W Max Fluorescent

500W Tungsten 850Va Ballast

100W Tungsten 1800Va Ballast

On/Off Lux Level

70 Lux (Dusk to Dawn)

70 Lux (Dusk to Dawn)

10-20 Lux On 30-60 Lux Off

10-20 Lux On 30-60 Lux Off

Dimensions (L x W x H)

57 x 31 x 25mm

57 x 31 x 25mm

52.5 x 42 x 29mm

52.5 x 42 x 29mm

Photocell Kits • • • • • •

Ideal for both residential and commercial applications Compatible with all Brackenheath LED floodlights Electronic detector for dusk/dawn switching Suitable for use within a luminaire 230V / 50Hz UV stabilised cover PS20

N2013

PS21

N2014

Heads & Photocell Kits PS20 PS21 N2013 N2014

400W photocell kit 400W photocell head only 1000W photocell kit 1000W photocell head only

Product Code

PS20

PS21

N2013

N2014 1000W Tungsten 1800Va Ballast

Switching Capacity

400W

400W

1000W Tungsten 1800Va Ballast

On/Off Lux Level

70 Lux (Dusk to Dawn)

70 Lux (Dusk to Dawn)

70 Lux On 105 Lux Off

Connection Method

26

t: 0845 884 7000

NEMA Socket

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

10-20 Lux On 30-60 Lux Off


Exterior Lighting Lighti ng Accessories

Brackets and Connectors • • •

Compatible with iSpot Frameless and REX Slim Floodlights up to 50W Steel construction Brackets have durable high quality black finish

Brackets and Connectors BTHB2A BTHB3A BTHB9A

BTHB2A

27

BTHB3A

Swivel corner bracket Swivel wall bracket Scaffold bracket

BTHB9A Product Code

BTHB2A

BTHB3A

BTHB9A

Movement

270°

180°

Fixed

Mounting Fixing Centres

60mm

Spikes • •

Ideal for residential floodlight applications Can be used in a garden, field or wooded area to allow a more direct beam angle from the floodlight

Spikes BTHB5A

Product Code

Zinc coated spike

BTHB5A

Movement

Fixed

Length

310mm

Mounting Fixing Centres

60mm

Fits

20W-30W BTHB5A

PIR Detectors • • • • • • • •

ENERGY SAVING

Recommended unit mounting height 1.8m - 2.5m approx. Detection Range 12m x 180º Adjustable timer 5 sec - 8 min Auto off/manual over-ride switching function Adjustable dusk-to-dawn sensor Maximum lighting load 250W (LED), 1200W (incandescent), 200W (fluorescent) Suitable for wall or ceiling mounting Built-in sensor prevents daytime operation

L2309B

PIR Detectors L2309B L2309W

L2309W

Adjustable 180 degrees PIR Adjustable 180 degrees PIR

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

27


LED Dualbay® Brackenheath’s LED Dualbay® series, available in 4000K or 6500K colour temperatures, provides a unique highbay or lowbay solution for warehouses, factories, school halls and gymnasiums and other large spaces. Dualbay® is compatible with intelligent controls and offers a microwave sensor accessory option. A microwave sensor accessory option is pre-factory set, providing significant operational cost savings and is simple to install. Remote control option provides easy way to change the settings from a floor standing position. Through innovation in design, Brackenheath has developed a Dualbay Mini range, providing a cost effective solution for today’s competitive market.

28

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Supplied with 2m of power flex

Hanging hook included Flicker free technology

Integral driver 4000K or 6500K colour temperature options

Plug in microwave sensor

IP65 rated for protection against dust and low-pressure jets of water

Dimmable with Remote Control Option

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

29


DualBay® Mini

ENERGY SAVING

• • • •

DualBay® Mini BR3501 BR3502

100W Mini LED Highbay 4000K 100W Mini LED Highbay 6500K

Product Code

BR3501

30

BR3502

Wattage

100W

Lumens

12,000 Lm

IP Rating

IP65

Colour Temperature

4000K

6500K

Beam Angle

90°

Voltage

220-240V (50-60Hz)

t: 0845 884 7000

|

• • • • • •

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

IP65

Available in 4000K & 6500K colour temperatures 120Lm/W Samsung LED chips IP65 rating for total protection against dust and lowpressure jets of water Maximum mounting height 8-10m Integral Non-dimmable driver Hanging hook included Flicker free technology Supplied with 2m of power flex 5 Year Guarantee


ENERGY SAVING

IP65

Dualbay® LED DualBay

DualBay®

31

• Available in 4000K & 6500K colour temperatures • 130 Lm/W • Osram LED chips • (0-10V) Dimmable IP65 LED Highbay • Hanging hook included • Flicker free technology • Supplied with 2m of power flex • Integral dimmable driver with Plug and Play Microwave xxxxsensor option • Remote control option for floor level operation • Emergency 3Hr battery option available • 5 Year Guarantee

DualBay® BR3511 BR3512 BR3513 BR3514 Product Code

150W 4000K IP65 150W 6500K IP65 200W 4000K IP65 200W 6500K IP65 BR3511

BR3512

BR3513

BR3514

Wattage

150W

200W

Lumens

19,500 Lm

26,000 Lm

Impact Rating

IK08

IP Rating

IP65

Colour Temperature

4000K

6500K

Voltage

4000K

6500K

100-240V (50-60Hz)

Beam Angle

90°

Rated Life (Hours)

50,000

HID Replacement

300W

400W

Accessories

150W & 200W Accessories BR3524 N9103 BR3523 BR3521 BR3522 BR3525

H holder for 150W-250W Aluminium cowl for 200W Aluminium cowl for 150W Plug-in Microwave Sensor Remote Control 3Hr Emergency Pack

Product Code

BR3521

Power Supply

12V - 24V DC, >50mA

Dim Control Output

0-10V, max. 25mA sinking current

HF System

5.8GHz+75MHz

Transmission Power

<0.2mW

Detection Radius

20%/50%/75%/100%(1-8m)

Mounting Height

Maz 40ft. (12meters)

Time Setting

10s/1min/5min/10min/15min/ 20min/30min/60min

Light - Control

24H/10LUX/30LUX/50LUX

Temperature

-40°F ~+ 158°F (-4°C ~ + 70°C)

IP Rating

IP65

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

31


LED Panels Brackenheath’s LED Panels are backlit, ensuring a uniform light distribution and an improved contrast. LED modules mounted at the back of the panels provide a direct light source and off er a superior lumens per watt performance. Panels are TP(b) rated. A new range of low glare panels (UGR<19) with CCT3 selection allows switching between 3000K, 4000K and 6000K. An emergency plug-in pack and Dali dimming driver is available for all models in the range.

32

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Latest backlit LED technology incorporated within a slim profile 30mm deep panel

White aluminium frame with high quality TP(b) diffuser

Loop in, loop out terminals provide for an easier and more economical installation

Up to 110 Lm/W

Compatible with Brackenheath's plug and play, self-test emergency pack Full range of accessories available for recessed, suspension or surface mounting

Supplied with ENEC approved driver

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

33


LED Panels

ENEC

APPROVED DRIVER

BR1111

ENERGY SAVING

IP20

5-YEAR GUARANTEE

BR1121

LED Panels BR1111 BR1112 BR1121 BR1122

32W 4000K IP20 600x600mm 32W 6000K IP20 600x600mm 45W 4000K IP20 600x1200mm 45W 6000K IP20 600x1200mm

BR1191

Remote 3hr emergency pack

Product Code

BR1111

BR1112

BR1191

BR1121

BR1122

Wattage

32W

45W

Lumens

3,500 Lm

5,500 Lm

Impact Rating

IK02

IP Rating

IP20

Colour Temperature

4000K

6000K

4000K

Voltage

220-240V (50-60Hz)

Beam Angle

110°

Rated Life (Hours)

50,000

6000K

LED Panel Accessories LED Panel Accessories BR1194 BR1193 BR1195

34

LED panel 6 wire suspension kit Panel surface mounting kit 600x600 Panel surface mounting kit 600x1200mm

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

LED Backlit Panels • Electronic control gear provides a low flicker light solution • External ENEC approved driver • TP(b) rated • Non-dimmable • Low glare (UGR<21) • Loop in, loop out terminals offer ease of installation • Surface and recessed mounting accessories available Self-Test 3hr Emergency Pack • Plug and play • Compatible with all Non-CCT3 Panels (square or rectangular) • Includes a trailing LED indicator for positioning alongside the panel • 12-60V output 6V 2.5Ah NI-CD/NI-MH battery • 3W output power • 200x100x33mm, 800g


APPROVED DRIVER

ENERGY SAVING

IP20

5-YEAR GUARANTEE

LED LEDPanels Panels

ENEC

LED CCT3 Panels

35

LED CCT3 Panels BR1113 BR1123

600x600MM 32W CCT3 Panel UGR<19 1200x600MM 50W CCT3 Panel UGR<19

BR1129

CCT3 3hr emergency pack

Product Code

BR1113

LED CCT3 Panels • CCT3 driver selector allows switching between 4000K, 5000K and 6000K • Electronic control gear provides flicker free light solution • External ENEC approved driver • TP(b) rated • Low glare (UGR<19) • Loop in, loop out terminals offer ease of installation • Surface and recessed mounting accessories available • 5 Year Guarantee

BR1123

Wattage

32W

50W

Lumens/W

3,500 Lm

5,500 Lm

Impact Rating

IP20

IP20

Colour Temperature

4000K/5000K/6000K

Voltage

220-240V 50Hz

Beam Angle

110°

Rated Life (Hours)

50,000

Self-Test 3hr Emergency Pack • Emergency pack is compatible with all CCT3 LED Panels using Standard or Dali or Zigbee Smart drivers

Dali Dimming Driver

ENEC

APPROVED DRIVER

ENERGY SAVING

IP20

5-YEAR GUARANTEE

Dali Dimming Driver BR1196 • • • • • • • • •

60W Dali Dimmable Driver (DALI+PUSH+0-10V)

LiFud Dali dimming driver Constant current output Current value can be selected via a DIP switch, 50mA every step Suitable for the Class I and Class II light fixtures Built-in active power factor correction function Stand-by power consumption less than 0.5W DALI dimming (logarithmic or linear dimming curves can be set via DALI interface) Synchronous dimming: up to 10 pcs of power supplies share one IP address 5 Year Guarantee

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

35


APPROVED DRIVER

ENERGY SAVING

IP20

5-YEAR GUARANTEE

LED LEDPanels Panels

ENEC

LED CCT3 Panels

35

LED CCT3 Panels BR1113 BR1123

600x600MM 32W CCT3 Panel UGR<19 1200x600MM 50W CCT3 Panel UGR<19

BR1129

CCT3 3hr emergency pack

Product Code

BR1113

LED CCT3 Panels • CCT3 driver selector allows switching between 4000K, 5000K and 6000K • Electronic control gear provides flicker free light solution • External ENEC approved driver • TP(b) rated • Low glare (UGR<19) • Loop in, loop out terminals offer ease of installation • Surface and recessed mounting accessories available • 5 Year Guarantee

BR1123

Wattage

32W

50W

Lumens/W

3,500 Lm

5,500 Lm

Impact Rating

IP20

IP20

Colour Temperature

4000K/5000K/6000K

Voltage

220-240V 50Hz

Beam Angle

110°

Rated Life (Hours)

50,000

Self-Test 3hr Emergency Pack • Emergency pack is compatible with all CCT3 LED Panels using Standard or Dali or Zigbee Smart drivers

Dali Dimming Driver

ENEC

APPROVED DRIVER

ENERGY SAVING

IP20

5-YEAR GUARANTEE

Dali Dimming Driver BR1196 • • • • • • • • •

60W Dali Dimmable Driver (DALI+PUSH+0-10V)

LiFud Dali dimming driver Constant current output Current value can be selected via a DIP switch, 50mA every step Suitable for the Class I and Class II light fixtures Built-in active power factor correction function Stand-by power consumption less than 0.5W DALI dimming (logarithmic or linear dimming curves can be set via DALI interface) Synchronous dimming: up to 10 pcs of power supplies share one IP address 5 Year Guarantee

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

35


LED CCT3 Round Panels

ENEC

APPROVED DRIVER

120MM 6W CCT3 Circular Panel 150MM 9W CCT3 Circular Panel 170MM 12W CCT3 Circular Panel 220MM 18W CCT3 Circular Panel

BR1129

CCT3 3hr emergency pack

IP20

Self-Test 3hr Emergency Pack • Emergency pack is compatible with all CCT3 LED

36

Product Code

BR1251

BR1252

BR1253

BR1254

Wattage

6W

9W

12W

18W

Lumens

450 Lm

630 Lm

840 Lm

1,500 Lm

Impact Rating

IK02

IP Rating

IP20

Colour Temperature

3000K/4000K/6000K

Voltage

220-240V (50-60Hz)

Beam Angle

110°

Rated Life (Hours)

50,000

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

5-YEAR GUARANTEE

LED CCT3 Panel • CCT3 driver selector allows switching between 3000K, 4000K and 6000K • Electronic control gear provides flicker free light solution • External ENEC approved driver • TP(b) rated • Low glare (UGR<21) • Loop in, loop out terminals offer ease of installation • Surface and recessed mounting accessories available • 5 Year Guarantee

LED CCT3 Round Panels BR1251 BR1252 BR1253 BR1254

ENERGY SAVING

|

w: deta.co.uk


LED Panels Panels LED 37

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

37


LED Weatherproofs Brackenheath’s new and improved LED Weatherproof - CCT3 & Power4 fittings provide a high performance and energy efficient solution; perfect for replacing old fluorescent technology. The CCT3 selectable option allows the installer to set the colour temperature (3000K/4000K/6500K). Power4 internal selector allows switching between four power options to change the lumen output. Incorporating a high strength opal diffuser, a quick fix, two-part hinged LED tray with tamper proof 304 stainless steel clips,

38

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


New and improved quick fix, two-part hinged LED tray design High performance linear weatherproof luminaire with integrated LED offering 120 Lm/W Polycarbonate construction with opal diffuser and stainless steel clips

Wide voltage range 100-240V (50-60Hz)

Single and twin output options equivalent to fluorescent lamp sources

Supplied with tamper proof, 304 stainless steel clips CCT3 selectable 3000K/4000K/6500K

20mm conduit knockouts and besa mounting options

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

39


LED Weatherproof - CCT3 & Power4

4ft LED CCT3 30/38/45/55W 5ft LED CCT3 30/38/45/55W 6ft LED CCT3 40/56/66/80W

LED Weatherproof CCT & Power4 - Microwave BR4253 BR4257 BR4261

Product Code

40

4ft LED CCT3 30/38/45/55W 5ft LED CCT3 30/38/45/55W 6ft LED CCT3 40/56/66/80W

BR4251

BR4253

APPROVED DRIVER

ENERGY SAVING

BR4255

BR4257

BR4259

BR4261

Length

4ft

5ft

6ft

Wattage

30/38/45/55W

30/38/45/55W

40/56/66/80W

Lumens/W

120 Lm/W

Impact Rating

IK08

IP Rating

IP65

Colour Temperature

3000K/4000K/6500K

Voltage

100-240V

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

IP65

• LED Weatherproof CCT3 and Power4 fixtures • 120 Lm/W • CCT3 internal selector allows switching between 3000K, xxxl4000K & 6500K • Power4 internal selector allows switching between four xxxlpower options to change the lumen output • Available in 4ft, 5ft, 6ft standard options • Anti-tamper proof 304 stainless steel clips • Push fit terminals requires no tools for electrical xxxlconnection • Quick fix, two-part hinged design allows installation with xxxlout having to fully disassemble the fitting • Connection option via 20mm conduit entry • Besa box mounting compatible • ENEC approved driver with low voltage protection • Wide voltage range 100-240V • Microwave corridor sensor is fully adjustable and allows xxxlswitching between sensitivity, hold times, illumination xxxlperiods and Lux light levels

LED Weatherproof CCT3 & Power4 BR4251 BR4255 BR4259

ENEC

w: deta.co.uk


ENEC

APPROVED DRIVER

ENERGY SAVING

IP65

LED Weatherproofs

LED Weatherproof CCT3 & Power4 Emergency

41

• LED Weatherproof CCT3 and Power4 fixtures • 120 Lm/W • CCT3 internal selector allows switching between 3000K, xxxl4000K & 6500K • Power4 internal selector allows switching between four xxxlpower options to change the lumen output • Available in 4ft, 5ft, 6ft standard options • Anti-tamper proof 304 stainless steel clips • Push fit terminals requires no tools for electrical xxxlconnection • Quick fix, two-part hinged design allows installation with xxxlout having to fully disassemble the fitting • Connection option via 20mm conduit entry • Besa box mounting compatible • ENEC approved driver with low voltage protection • Wide voltage range 100-240V • Microwave corridor sensor is fully adjustable and allows xxxlswitching between sensitivity, hold times, illumination xxxlperiods and Lux light levels • LiFePO4 Lithium battery provides improved energy consumption, product reliability and lifetime

LED Weatherproof CCT & Power4 - Emergency BR4252 BR4256 BR4260

4ft LED CCT3 30/38/45/55W 5ft LED CCT3 30/38/45/55W 6ft LED CCT3 40/56/66/80W

LED Weatherproof CCT & Power4 - Microwave Emergency BR4254 BR4258 BR4262

Product Code

4ft LED CCT3 30/38/45/55W 5ft LED CCT3 30/38/45/55W 6ft LED CCT3 40/56/66/80W

BR4252

BR4254

BR4256

BR4258

BR4260

BR4262

Length

4ft

5ft

6ft

Wattage

30/38/45/55W

30/38/45/55W

40/56/66/80W

Lumens/W

120 Lm/W

Impact Rating

IK08

IP Rating

IP65

Colour Temperature

3000K/4000K/6500K

Voltage

100-240V

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

41


LED Weatherproof

ENEC

APPROVED DRIVER

• • • • • •

LED Weatherproof BR4112 BR4114 BR4115 BR4116

2ft 27W 6500K IP65 4ft 40W 6500K IP65 5ft 40W 6500K IP65 6ft 60W 6500K IP65

Suitable for commercial and industrial applications Energy savings up to 50% compared to fluorescent luminaires Improved quick fix, two-part hinged design LED tray Supplied with tamper proof, 304 stainless steel clips Operating temperature -25°C to +50°C Besa box mounting compatible

LED Weatherproof - High Power BR4114T BR4115T BR4116T

4ft 55W 6500K IP65 5ft 55W 6500K IP65 6ft 80W 6500K IP65

Product Code

42

BR4112

BR4114

BR4115

BR4116

BR4114T

BR4115T

BR4116T

Length

2ft

4ft

5ft

6ft

4ft

5ft

6ft

Wattage

27W

40W

40W

60W

55W

55W

80W

Lumens

3,240 Lm

4,800 Lm

4,800 Lm

7,200 Lm

6,600 Lm

6,600 Lm

9,600 Lm

Lumens/Watt

120 Lm/W

Impact Rating

IK08

IP Rating

IP65

Colour Temperature

6500K

Voltage

100-240V (50-60Hz)

Beam Angle

120°

Rated Life (Hours)

50,000

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

ENERGY SAVING

w: deta.co.uk

IP65


ENEC

APPROVED DRIVER

ENERGY SAVING

IP65

LED Weatherproofs

LED Weatherproof - Emergency

43

• • • • • • •

LED Weatherproof - Emergency BR4112E BR4114E BR4115E BR4116E

2ft 27W 6500K IP65 EM 4ft 40W 6500K IP65 EM 5ft 40W 6500K IP65 EM 6ft 60W 6500K IP65 EM

Suitable for commercial and industrial applications Energy savings up to 50% compared to fluorescent luminaires Improved quick fix, two-part hinged design LED tray Supplied with tamper proof, 304 stainless steel clips Operating temperature 0°C to +50°C Besa box mounting compatible LiFePO4 Lithium battery provides improved energy consumption, product reliability and lifetime

LED Weatherproof - Emergency High Power BR4114TE BR4115TE BR4116TE

4ft 55W 6500K IP65 EM 5ft 55W 6500K IP65 EM 6ft 80W 6500K IP65 EM

Product Code

BR4112E

BR4114E

BR4115E

BR4116E

BR4114TE

BR4115TE

BR4116TE

Length

2ft

4ft

5ft

6ft

4ft

5ft

6ft

Wattage

27W

40W

40W

60W

55W

55W

80W

Lumens

3,240 Lm

4,800 Lm

4,800 Lm

7,200 Lm

6,600 Lm

6,600 Lm

9,600 Lm

Lumens/Watt

120 Lm/W

Impact Rating

IK08

IP Rating

IP65

Colour Temperature

6500K

Voltage

100V-240V (50-60Hz)

Beam Angle

120°

Rated Life (Hours)

50,000

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

43


Exterior Wall Lights Brackenheath’s Exterior Wall Lights offer a range of decorative luminaires for lighting outdoor spaces, including gardens, doorways and patios. The range includes a selection of stylish stainless steel or black powder coated wall lights and lanterns, complementing any modern home.

44

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

45


Wall Lights - Up/Down • • • • •

IP44

Ideal for residential applications including domestic gardens and walkways Modern, aesthetically pleasing design Stainless steel durable 304 grade body and glass diffuser Black powder coated stainless steel body and glass diffuser Supplied without lamp

Wall Lights - Up/Down GF622 GF6012

Up/down - stainless steel Up/down - black GF622

GF6012

Wall Lights - Up/Down with PIR • • • • • • • •

IP44

Ideal for residential applications including domestic gardens and walkways PIR has manual override feature PIR adjustable settings: lux, time and sensitivity PIR detection range of up to 8 metres Modern, aesthetically pleasing design Stainless steel durable 304 grade body and glass diffuser Black powder coated stainless steel body and glass diffuser Supplied without lamp

Wall Lights - Up/Down with PIR GF625 GF6013

Up/down PIR - stainless steel Up/down PIR - black

Product Code

46

GF622

GF6012

GF625

GF625

Wattage

Lamp maximum use 35W

Lamp Type

GU10

IP Rating

IP44

Voltage

220-240V

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

GF6013

w: deta.co.uk

GF6013


• • • • •

IP44

Ideal for residential applications including domestic gardens and walkways Modern, aesthetically pleasing design Stainless steel durable 304 grade body and glass diffuser Black powder coated stainless steel body and glass diffuser Supplied without lamp

Exterior Wall Lights

Wall Lights - Fixed and Adjustable

47

Wall Lights - Fixed GF621 GF6010

Fixed - stainless steel Fixed - black

Wall Lights - Adjustable GF623 GF6011

Product Code

GF621

GF6010

GF623

GF6011

Adjustable - stainless steel Adjustable - black

GF6010

GF6011

GF621

Wattage

35W

Lamp Type

GU10

IP Rating

IP44

Voltage

220-240V

GF623

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

47


LED Bulkheads Brackenheath’s LED Bulkheads incorporate the latest LED technology with CCT3, microwave and emergency options available. A chrome clip-on bezel accessory is available, offering flexibility for individual lighting requirements. Installation is quick and easy, with the bezel and diffuser easily removed, providing access to gear tray and fixing points. The range is ideal for both domestic and commercial applications.

48

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Spectra Bulkheads Ø320mm diameter body which is ideal for retrofit replacements

Chrome trim accessories available

CCT3 dip switch on LED tray for 3000K, 4000K, 6000K colour temperature options

Polycarbonate base and diffuser for increased durability Microwave sensor and emergency versions available

Interior and exterior bulkheads ideal for residential or commercial applications

Hinged installation tray allows easy installation

White round trims supplied as standard

Supplied with push fit connectors

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

49


Spectra LED CCT3 IP65

ENEC ENERGY SAVING

APPROVED DRIVER

BR6195C

• • • • •

Standard BR6111

18W CCT3 IP65 - white

Standard + Microwave Sensor BR6111M

• • •

18W CCT3 IP65 MW - white

Standard + Emergency BR6111E

Microwave Sensor • Microwave sensor with corridor function • Up to 360° detection within 6m range • Easily adjustable after initial installation • 6m maximum ceiling mounting height • 3m maximum wall mounting height • Adjustable hold time - 5 secs / 1 min / 3 mins / 10 mins • Adjustable sensitivity - 50% / 100%

18W CCT3 IP65 EM - white

Standard + Microwave Sensor + Emergency BR6111EM

18W CCT3 IP65 MW + EM - white

Emergency • 3 hour emergency feature • 3W power consumption in emergency mode

Accessories BR6195C

50

CCT3 as standard (3000K/4000K/6000K) Energy savings of up to 55% compared to luminaires that use CFL ENEC approved driver Hinge feature on tray allows for easy installation Surface mounting luminaire with 4 side and 1 rear 20mm conduit entry points High impact polycarbonate housing Ø320mm diameter body which is ideal for retrofit replacements Decorative chrome bezel accessory available

Chrome bezel

Product Code

BR6111

BR6111M

BR6111E

BR6111EM

Finish

White

White

White

White

Wattage

18W

Lumens

1,550 Lm

Impact Rating

IK10

IP Rating

IP65

Colour Temperature

3000K/4000K/6000K

Voltage

220-240V

Rated Life (Hours)

30,000

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

IP65


• • • • •

ENERGY SAVING

IP65

CCT3 as standard (3000K/4000K/6000K) Ideal for commercial and residential applications CCT3 dip switch on LED tray Tamper proof construction Manufactured with flame retardant polycarbonate

51

Microwave Sensor • Up to 360° detection within 6m range • Easily adjustable after initial installation • 6m maximum ceiling mounting height • 3m maximum wall mounting height • Adjustable hold time - 5 secs / 1 min / 3 mins / 10 mins • Adjustable sensitivity - 50% / 100% Emergency • 3 hour emergency feature • 3W power consumption in emergency mode

Standard E9708

Standard + Microwave Sensor E9709

LED CCT3 IP65 MW- white

Standard + Emergency E9710

E9705

Product Code LED CCT3 IP65 - white

LED CCT3 IP65 EM - white

LED Bulkheads

LED CCT3 IP65 Drum

E9708

E9709

E9710

Wattage

18W

Lumens

1,400 Lm

Impact Rating

IK10

IP Rating

IP65

Colour Temperature

3000K/4000K/6000K

Voltage

220-240V

Beam Angle

120°

Rated Life (Hours)

30,000

E9711

Standard + Microwave Sensor + Emergency E9711

LED CCT3 IP65 MW + EM - white

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

51


LED CCT3 IP54 • • • • •

ENERGY SAVING

CCT3 as standard (3000K/4000K/6000K) Ideal for commercial and residential applications CCT3 dip switch on LED tray Tamper proof construction Manufactured with flame retardant polycarbonate

Microwave Sensor • Up to 360° detection within 6m range • Easily adjustable after initial installation • 6m maximum ceiling mounting height • 3m maximum wall mounting height • Adjustable hold time - 5 secs / 1 min / 3 mins / 10 mins • Adjustable sensitivity - 50% / 100% Emergency • 3 hour emergency feature • 3W power consumption in emergency mode

E9700

Standard E9700

LED CCT3 IP54

Standard + Microwave Sensor E9701

LED CCT3 IP54 MW

Standard + Emergency E9702

LED CCT3 IP54 EM

E9703

Standard + Microwave Sensor + Emergency E9703

Product Code

52

LED CCT IP54 MW + EM

E9700

E9701

E9702

Wattage

18W

E9703

Lumens

1,350 Lm

Impact Rating

IK10

IP Rating

IP54

Colour Temperature

3000K/4000K/6000K

Voltage

220-240V

Beam Angle

120°

Rated Life (Hours)

30,000

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

IP54


• • • • • • • • • • • •

ENERGY SAVING

IP44

Recommended unit mounting height 1.8m - 2.5m Detection range 12m x 110º Adjustable timer 5 sec - 5 min approx. Auto off/manual over-ride switching function Built-in adjustable sensor prevents daytime operation Maximum detector lighting load 500W Adjustable dusk-to-dawn sensor Cable channels moulded into rear casing Black body with prismatic diffuser ES27 lampholder maximum 60W Available with a choice of 9.5W 2800K or 4000K LED lamps IP44 rated

LED Bulkheads

Compact Bulkhead with PIR

53

Bulkhead with PIR L2305

Compact bulkhead with PIR and 9.5W 2800K/4000K Lamp

L2035

LED Bulkhead with PIR L2305LED3 L2305LED4

9.5W 2800K IP44 9.5W 4000K IP44

Product Code

L2305

Wattage

Lumens

IP Rating Colour Temperature

L2305LED4 9.5W

810 Lm IP44

Voltage Rated Life (Hours)

L2305LED3

2800K

4000K

220-240V –

50,000

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

53


LED Corn Lamps Brackenheath's LED Corn Lamps are designed to replace metal halide and high pressure sodium lamps, offering substantial energy savings of up to 80% and increasing the rated life up to 50,000 hours. The new radiator design eliminates the need for a fan, reducing noise levels and increasing life expectancy, providing a more reliable and economical solution.

54

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Internal driver Direct LED replacements for old technology lamps Unique radiator design eliminates the need for a fan

IP64 rating for total protection against dust and low-pressure jets of water

ErP Compliant

Wide voltage range AC 100V - 240V 360° light output

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

55


LED Corn Lamps - E27

ENERGY SAVING

R8027

R8019

56

LED Corn Lamps - E27

• •

R8019 R8027

• • • • • • • • •

18W 6500K IP64 27W 6500K IP64

Product Code

R8019

Wattage

18W

27W

MH Equivalent

70W

100W

Lumens

2,660 Lm

3,780 Lm IP64

Colour Temperature

6500K

Voltage

100-240V

Rated Life (Hours)

50,000

|

Ideal for commercial applications including warehouses and factories Aluminium body construction with polycarbonate diffuser, with unique heatsink design eliminating the need for a fan 360° light output Rated life of 50,000 hours Wide voltage range 100V - 240V Can be used in open or closed fittings Radiator design to allow heat dissipation Internal driver Direct replacement for metal halide Easy installation Fitting compatible for use with PIR sensors

R8027

IP Rating

t: 0845 884 7000

IP64

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


ENERGY SAVING

IP64

LEDCorn CornLamps Lamps LED

LED Corn Lamps - E40

57

R8100

R8080

LED Corn Lamps - E40

• •

R8036 R8054 R8080 R8100

• • • • • • •

36W 6500K IP64 54W 6500K IP64 80W 6500K IP64 100W 6500K IP64

Ideal for commercial applications including warehouses and factories Aluminium body construction with polycarbonate diffuser, with unique heatsink design eliminating the need for a fan 360° light output Rated life of 50,000 hours Wide voltage range 100V - 240V Can be used with PIR sensors Can be used in open or closed fittings Radiator design to allow heat dissipation Internal driver

Product Code

R8036

R8054

R8080

R8100

Wattage

36W

54W

80W

100W

MH Equivalent

120W

150W

250W

250W

Lumens

5,040 Lm

7,560 Lm

11,200 Lm

14,000 Lm

IP Rating

IP64

Colour Temperature

6500K

Voltage

100-240V

Rated Life (Hours)

50,000

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

57


LED Batten Fittings Brackenheath's LED Batten Fittings include a comprehensive selection of single and twin fittings, as well as slimline fittings with CCT3 and emergency options. All fittings are easy to install with fast mounting push clips and push-fit connectors and are offered in a wide selection of sizes. The new Professional range offers CCT3 as standard and is available in standard and emergency options. With a steel body construction, 20mm conduit entry points and a high performance LED output, these fittings are suitable for a direct fix to trunking and conduit mounting and offer an energy efficient replacement for traditional fluorescent pop packs. The Slimline batten range is available with and without a selectable CCT3 option. The CCT3 option is dimmable and is supplied with a remote which allows the user to control the colour temperature range from 3000K to 6000K.

58

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Contents LED Professional Battens LED Slimline Battens

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

60 - 61 62 - 63

|

w: deta.co.uk

59


LED Professional Battens - CCT3

4ft 20W CCT3 IP20 5ft 30W CCT3 IP20 6ft 40W CCT3 IP20

LED Professional Battens - CCT3 Twin BR5114T BR5115T BR5116T

4ft 40W CCT3 IP20 5ft 60W CCT3 IP20 6ft 67W CCT3 IP20

Product Code

60

BR5114

APPROVED DRIVER

BR5115

BR5116

BR5114T

BR5115T

BR5116T

Length

4ft

5ft

6ft

4ft

5ft

6ft

Wattage

20W

30W

40W

40W

60W

67W

Lumens

2,000 Lm

3,000 Lm

4,000 Lm

4,000 Lm

6,000 Lm

8,000 Lm

Lumens per Watt

100 Lm/W

IP Rating

IP20

Colour Temperature

3000K/4000K/6500K

Beam Angle

120°

Rated Life (Hours)

50,000

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

IP20

5-YEAR GUARANTEE

• High performance LED batten option for multi-purpose applications • CCT3 internal selector allows switching between 3000K, 4000K and xxxl6500K • Single and twin options available • Instant light output with unlimited switching • Connection option via 20mm conduit entry • Steel body construction with powder coat finish • Polycarbonate diffuser and end caps • Wire suspension kit option available • ENEC approved driver

LED Professional Battens - CCT3 BR5114 BR5115 BR5116

ENEC ENERGY SAVING

|

w: deta.co.uk


ENEC ENERGY SAVING

APPROVED DRIVER

IP20

5-YEAR GUARANTEE

LED LEDBatt Batten ensFittings

LED Professional Battens - CCT3 Emergency

61

LED Professional Battens - CCT Emergency

• •

BR5114E BR5115E BR5116E

• • • • • • • •

4ft 20W CCT IP20 Em 5ft 30W CCT IP20 Em 6ft 40W CCT IP20 Em

LED Professional Battens - CCT Emergency Twin BR5114TE BR5115TE BR5116TE

Product Code

4ft 40W CCT IP20 Em 5ft 60W CCT IP20 Em 6ft 67W CCT IP20 Em

BR5114E

BR5115E

BR5116E

High performance LED batten option for multi-purpose applications CCT3 internal selector allows switching between 3000K, 4000K and 6500K Single and twin options available Instant light output with unlimited switching Connection option via 20mm conduit entry Steel body construction with powder coat finish Polycarbonate diffuser and end caps Wire suspension kit option available ENEC approved driver LiFePo4 Lithium emergency 3Hr battery

BR5114TE

BR5115TE

BR5116TE

Length

4ft

5ft

6ft

4ft

5ft

6ft

Wattage

20W

30W

40W

40W

60W

67W

Lumens

2,000 Lm

3,000 Lm

4,000 Lm

4,000 Lm

6,000 Lm

8,000 Lm

Lumens per Watt

100 Lm/W

IP Rating

IP20

Colour Temperature

3000K/4000K/6500K

Beam Angle

120°

Rated Life (Hours)

50,000

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

61


2ft 2ft

T2040 T2040

LED Slimline Battens - Dimmable CCT

4ft 4ft

T2050 T2050

£20.85 £20.85 ENERGY SAVING

EACH EACH IP20

3-YEAR GUARANTEE

£31.30 £31.30

EACH EACH

5ft 5ft

T2060 T2060

£41.75 £41.75

EACH EACH

6ft 6ft

T2070 T2070

£47.00 £47.00

EACH EACH

Battens • Dimmable and colour changeable with remote control • Suitable for surface and ceiling mounting • Ultra slim aluminium body with PC end caps • Integrated LED driver • Supplied with extra-long power lead for central mounting • Supplied with mounting brackets • Dimmable from 3% to 100% • Memory function automatically restores last CCT setting • BR5410 remote sold separately,

LED Slimline Battens - Dimmable CCT BR5412 BR5414 BR5415 BR5416

2ft 18W CCT IP20 4ft 36W CCT IP20 5ft 50W CCT IP20 6ft 72W CCT IP20

LED Slimline Battens - Dimmable CCT Remote BR5410

Dimmable CCT Remote

Product Code

BR5412

BR5414

BR5415

BR5416

2ft

4ft

5ft

6ft

Length

62

Remote • On/Off, Dimming and CCT control options from remote • Control operation up to 30m • Four control channels allow for simultaneous control of up to: - 50 x 2ft battens - 25 x 4ft battens - 20 x 5ft battens - 16 x 6ft battens

Wattage

18W

36W

50W

72W

Lumens

1,600 Lm

3,200 Lm

4,000 Lm

5,760 Lm

IP Rating

IP20

Colour Temperature

3000K up to 6000K

Rated Life (Hours)

20,000

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

15 15


ENERGY SAVING

IP20

3-YEAR GUARANTEE

LED LED Batt Batten ensFittings

LED Slimline Battens

63

• • • •

LED Slimline Battens - 4000K T2041 T2051 T2061 T2081

Product Code

2ft 18W 4000K IP20 4ft 36W 4000K IP20 5ft 50W 4000K IP20 6ft 72W 4000K IP20

T2041

T2051

T2061

Suitable for surface and ceiling mounting Ultra slim aluminium body with PC end caps LED built in driver Supplied with extra-long power lead for central mounting Supplied with mounting brackets

T2081

Length

2ft

4ft

5ft

6ft

Wattage

18W

36W

50W

72W

Lumens

1,440 Lm

2,880 Lm

4,000 Lm

5,760 Lm

IP Rating

IP20

Colour Temperature

4000K

Rated Life (Hours)

25,000

Wire Suspension Kit LED Batten (20mm Conduit Entry) BR5194

Wire Suspension Kit

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

63


LED Under Cabinet Lighting Brackenheath’s LED Under Cabinet Lighting range can be easily linked or butted together to create a continuous lighting effect over a large surface area and is perfect for illuminating displays and kitchen surfaces. With CCT3 incorporated as a standard feature, offering three colour temperatures (3000K/4000K/6000K) within one fixture, the range provides installers and end users with full flexibility.

64

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


• • • • • • •

ENERGY SAVING

IP20

LED CCT Link Lights

Ideal solution for both home and office applications Suitable for surface and ceiling mounting Manufactured with a slide switch to adjust colour temperature and switch on/off 3-YEAR 20,000 lifetime operation hoursLED INDOOR Ultra slim aesthetically pleasing body Supplied with 1.8m power lead- and mounti ng brackets Supplied with 1.8m power lead and mounting brackets Operating voltage of 100V-240V AC ENERGY SAVING

Under Cabinet Lighting

LED Under Cabinet Lighting - CCT3

GUARANTEE

65

- Adjustable colour temperature 3000K, 4500K and 6500K - Ultra slim body T3071 - Memory function automatically restores last CCT setting LED Under Cabinet Lighting- -Suitable CCT3for surface and ceiling mounting

T3071 T3072 T3073 T3074 T3075

- End to end connection

313mm 4W CCT3 573mm 8W CCT3 873mm 10W CCT3 907mm 12W CCT3 1173mm 14W CCT3

CCT3 3000K/4000K/6000K Product Code

T3071

T3072

Length

313mm

4W 573mm

Wattage

4W

Lumens

320 Lm

8W T3071 640 Lm

IP Rating

T3074

8W 1173mm 907mm

£5.15 800 Lm

960 Lm

EACH

10W T3073

£8.30

EACH

1,120 Lm

£9.35

£10.40

EACH

120°

Connecting leads

Accessories

Spare power lead

500mm

1000mm

1.8m

£0.50 £0.90

£1.40

£0.35

150mm EACH

Leads for the above CCT range Available in different lengths to suit all applications

T3079

T3077 T3078 T3079

£7.25

T3072 14W 10W EACH 12W

12W3000K/4000K/6000K 14W EACH T3075 T3074

Beam Angle

Link Leads

T3075

IP20

Colour Temperature

• •

T3073

873mm

EACH

T3077

EACH

EACH

T3078

T3076

18 500mm link lead 1000mm link lead 150mm link lead

Spares T3076

1.8m power lead

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

65


IP65 Integrated LED Fire Rated Downlights Brackenheath’s IP65 Integrated LED Fire Rated Downlights are compact and versatile with a lens optimised to ensure even dispersion of flicker free light at a 38◦ beam angle. The IP65 range is comprised of warm white, cool white options, and provides 30 minutes in multiple engineered I-joist and metal web joist floor constructions* (Part B of Building Regulations).

66

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


IC-F

RATED

DIMMABLE

IP65

INSULATION COVERABLE

3-YEAR GUARANTEE

LEDDownlight Downlights LED

Integrated LED Fire Rated Downlights

67 xxxxi

L1402WH3

Dimmable integrated LED fire rated downlight for residential and commercial applications, optimised for use with Deta Universal Dimmers • Interchangeable twist and lock white bezel supplied as xxxxstandard, Polished Chrome (L1409CH) and Stainless Steel xxxx(L1409SS) bezels available as accessories • 6W, 550 Lm, 3000K (Warm White) and 4000K (Cool xxxxWhite) options, 38° Beam Angle, IP65, 220-240V • IP65 rating for total protection against dust and low xxxxixxxipressure jets of water from any direction • Fire resistance tested and approved for 30 minutes in xxxxmultiple engineered I-joist and metal web joist floor xxxxixxxiconstructions* (Part B of Building Regulations) • IC rated construction allows insulation to be laid directly xxxxover the top of the fitting, mounting springs suitable for xxxxsingle and double thickness plaster board • Mounting springs suitable for single and double thickness xxxxplaster board • Remote driver with loop-in/loop-out screwless terminal xxxxblock for easy termination of T&E cables • 3-year guarantee

Dimmable L1402WH3 L1402WH4

6W 3000K IP65 dim 6W 4000K IP65 dim

Twist and Lock Bezels L1409CH L1409SS

Product Code

Polished chrome Stainless steel

L1402WH3

L1402WH4

Wattage

6W

Lumens

550 Lm

IP Rating

IP65

Colour Temperature

3000K

4000K

Voltage

220-240V

Beam Angle

38°

*Please contact Deta’s Technical Support team for details of floor constructions

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

67


Since its inception in 1908, Briticent Site Electrics has enjoyed over 100 years of successful trading with a long-standing customer base. Briticent built its reputation on the Gripper® range of handlamps, and over the years has developed a core range of essential site lighting and power distribution products. Acquired by Deta in 2009, Briticent has led the market with new innovative and energy saving products, becoming the brand of choice for many electrical installers throughout the UK.

68

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Contents LED Non-Corrosive Fittings REX Slim LED Floodlights Step Down Transformers Cable Reels & Extension Leads Festoon Lighting & Power LED Plasterers Lights LED Task Lights LED Bulkheads Inspection Lighting Ancillaries

t: 0845 884 7000

|

70 - 75 76 - 79 80 - 83 84 - 87 88 - 93 94 - 97 98 - 103 104 - 109 110 - 111 112 - 113

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

69


LED Non-Corrosive Fittings Briticent’s LED Non-Corrosive Fittings are recognised for their quality and reliability amongst temporary light installers throughout the UK. The range includes standard and emergency integrated LED fittings in 2ft, 4ft and 5ft lengths. Ideal for use on construction sites as the wide voltage range from 100V to 240V protects against voltage spikes. Permanent weatherproof fittings are available within Brackenheath offering, please see pages 38 to 43.

70

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


High performance site luminaire with integrated LED offering 120 Lm/W

Polycarbonate diffuser and body construction ENEC approved driver with low voltage protection, driver will automatically reset if voltage drops below 100V

New and improved quick fix, two-part hinged LED tray design

20mm conduit knockouts and besa mounting options

LiFePo4 Lithium emergency 3Hr battery

Pre-wired with a weatherproof connection box option available

Wide voltage range 100-240V (50-60Hz)

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

71


LED Non-Corrosive Fittings

ENEC

APPROVED DRIVER

IP65

BI4112

• • • • • • • •

LED Non-Corrosive Fittings BI4112 BI4114 BI4115

2ft 27W 6500K IP65 4ft 40W 6500K IP65 5ft 40W 6500K IP65

LED Non-Corrosive Fittings - Emergency BI4112E BI4114E BI4115E

72

Emergency • 3 hour emergency function • Operating temperature 0°C to +50°C • Pre-wired with 4-Core cable • LiFePO4 Lithium battery provides improved energy consumption, product reliability and lifetime

2ft 27W 6500K IP65 EM 4ft 40W 6500K IP65 EM 5ft 40W 6500K IP65 EM

Product Code

BI4112

BI4112E

Suitable for industrial and commercial applications Energy savings of up to 50% compared to fluorescent luminaires Available in 2/4/5ft options Improved quick fix, two-part hinged LED tray design Wide voltage range 100-240V (50-60Hz) Operating temperature -25°C to +50°C (non-emergency only) Besa box mounting compatible ENEC approved driver

BI4114

BI4114E

BI4115

Size

2ft

Wattage

27W

40W

Lumens

3,240 Lm

4,800 Lm

4ft

Lumens/Watt

120 Lm/W

Impact Rating

IK08

IP Rating

IP65

Colour Temperature

6500K

5ft

Voltage

100-240V (50-60Hz)

Beam Angle

120°

Rated Life (Hours)

50,000

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

BI4115E


ENEC

APPROVED DRIVER

IP65

LED Non-Corrosive

LED Non-Corrosive Fittings + Plexo

73

BI4112P

BI4112PE

• • • • • • • • •

LED Non-Corrosive Fittings + Plexo BI4112P BI4114P BI4115P

2ft 27W 6500K IP65 4ft 40W 6500K IP65 5ft 40W 6500K IP65

LED Non-Corrosive Fittings + Plexo - Emergency BI4112PE BI4114PE BI4115PE

Product Code Size

2ft 27W 6500K IP65 EM 4ft 40W 6500K IP65 EM 5ft 40W 6500K IP65 EM

BI4112P

BI4112PE 2ft

Suitable for industrial and commercial applications Energy savings of up to 50% compared to fluorescent luminaires Available in 2/4/5ft options Supplied with 0.5m pre wired lead and terminal box Improved install quick fix design - two part construction Wide voltage range 100-240V (50-60Hz) Operating temperature -25°C to +50°C (non-emergency only) Besa box mounting compatible ENEC approved driver

Emergency • 3 hour emergency function • Operating temperature 0°C to +50°C • Pre-wired with 4-Core cable • LiFePO4 Lithium battery provides improved energy consumption, product reliability and lifetime

BI4114P

BI4114PE

BI4115P

4ft

5ft

Wattage

27W

40W

Lumens

3,240 Lm

4,800 Lm

Lumens/Watt

120 Lm/W

Impact Rating

IK08

IP Rating

IP65

Colour Temperature

6500K

BI4115PE

Voltage

100-240V (50-60Hz)

Beam Angle

120°

Rated Life (Hours)

50,000

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

73


LED Linkable Non-Corrosive Fittings

ENEC

APPROVED DRIVER

IP65

BI3112E

• • • •

LED Linkable Non-Corrosive Fittings BI3112

2ft 27W 6500K IP65

LED Linkable Non-Corrosive Fittings - Emergency BI3112E

2ft 27W 6500K IP65 EM

• • • •

Suitable for industrial and commercial applications Energy savings of up to 50% compared to fluorescent luminaires Available in 2ft option Supplied with 1.0m pre wired leads with 110V male and female plugs for quick installation Daisy chain up to 20 battens in series Wide voltage range 100-240V (50-60Hz) Operating temperature -25°C to +50°C (non-emergency only) ENEC approved driver

Emergency • 3 hour emergency function • Operating temperature 0°C to +50°C • Pre-wired with 3-Core cable • LiFePO4 Lithium battery provides improved energy consumption, product reliability and lifetime

Product Code

BI3112

Size

74

BI3112E 2ft

Wattage

27W

Lumens

3,240 Lm

Lumens/Watt

120 Lm/W

Impact Rating

IK08

IP Rating

IP65

Colour Temperature

6500K

Voltage

100-240V (50-60Hz)

Beam Angle

120°

Rated Life (Hours)

50,000

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

LED Linkable Non-Corrosive Fittings - Emergency are pre-wired with 3-Core cable, keeping circuits with emergency luminaires permanently on, avoiding battery packs from getting damaged through repetitive discharging.

|

w: deta.co.uk


LED Non-Corrosive t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

75


LED Floodlights Briticent’s 110V REX Slim LED Floodlights offers installers a range of models from 50W to 300W. Driver on board technology, combined with a high quality aluminium casing and a toughened glass lens, ensures a sleek yet durable design. A heavy duty, swivel mounting bracket allows the unit to be installed in a range of positions. Brackenheath 230V and Dual Voltage (100V-240V) REX Slim LED Floodlights are also available, please see pages 12 to 19.

76

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


110V driver on board technology provides sleek appearance

High quality yellow aluminium body and toughened glass

Highly efficient LED chips

Supplied with pre-wired power cable designed for construction use

Suitable for industrial and commercial applications

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

77


Rex Slim LED Floodlights 110V

N6280

N6283

• • •

Rex Slim 110V N6279 N6280 N6281 N6282 N6283

50W 4000K IP65 70W 4000K IP65 100W 4000K IP65 150W 4000K IP65 300W 4000K IP65

Product Code

N6279

• • • •

N6280

N6281

Suitable for industrial and commercial applications Replaces up to 400W metal halide or sodium fittings IP65 rating for total protection against dust and low pressure jets of water Highly efficient LED chips Driverless technology Angled bracket for easy installation Pre-wired with 1.5m of power cable

N6282

N6283

Wattage

50W

70W

100W

150W

300W

Lumens

4,500 Lm

6,300 Lm

9,000 Lm

13,500 Lm

27,000 Lm

Impact Rating

IK07

IP Rating

IP65

Colour Temperature

4000K

Voltage

110-140V (50-60Hz)

Beam Angle

120°

HID Replacement

78

ENERGY SAVING

t: 0845 884 7000

100W

|

150W

e: sales.lfs@deta.co.uk

250W

|

300W

w: deta.co.uk

700W

IP65


REX LED Floodlights REX Floodlights

Tripod Accessory Kit

79

Suitable for use with 50W, 70W and 100W REX Slim 110V floodlights

S4100

Tripod Accessory Kit S4100

Heavy duty tripod + 2m extension cable

• •

Ideal for use in industrial and commercial applications Supplied with 2m power extension cable and an IP65 weatherproof connector

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

79


Step Down Transformers Briticent’s Step Down Transformers offer a range of portable and site supply transformers with intermittent ratings from 1kVA to 10kVA. Portable transformers offer the perfect solution where power needs to be reduced from 230V to 110V and are available in 1kVA, 1.5kVA, 3.3kVA and 5kVA models. 10kVA MCB protected site supply transformers, incorporating a heavy duty metal casing and stand, are available in both single phase (230V to 110V) or three phase (415V to 110V) models, offering a power distribution solution for construction sites.

80

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


GRP rugged case with carry handle

Fitted with two IP44 rated sockets, and 2m of cable

230V mains to 110V transformer

Includes a safety overload device for added protection

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

81


Portable Transformers

1000/2/B

IP44

3300/2/B

• • • • •

1kVA portable 1.5kVA portable 3.3kVA portable 5kVA portable

82

Suitable for all applications where power needs to be reduced 230V to 110V Robust GRP case with carry handle Resettable thermal cutout Supplied with 2m cable and 13A plug

Product Code

1000/2/B

1500/2/B

3300/2/B

5000/3/B

Intermittent Rating

1.0kVA

1.5kVA

3.3kVA

5kVA

Continuous Rating

0.6kVA

0.9kVA

2.2kVA

2.8kVA

Cable Length

2m

Socket Outlets

2 x 16A

2 x 16A

2 x 16A

2 x 16A 1 x 32A

Weight

12.5kg

13kg

18kg

29kg

Input Voltage

230V

Output Voltage

110V

IP Rating

IP44

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

GUARANTEE

5000/3/B

Portable transformers 1000/2/B 1500/2/B 3300/2/B 5000/3/B

1-YEAR

w: deta.co.uk


• • • •

IP44

2-YEAR GUARANTEE

Suitable for power distribution on construction sites High quality metal casing with heavy duty stand MCB protected input and output Supplied with 4 x 16A outlets and 2 x 32A outlets

Step Down Transformers Transformers

Site Transformers

83 Single Phase Transformer 10000/1PH

10kVA step down

Three Phase Transformer 10000/3PH

10kVA step down

Product Code

10000/1PH

10000/3PH

Intermittent Rating

10kVA

10kVA

Continuous Rating

7kVA

7kVA

Cable Length

2m

2m

Socket Outlets

4 x 16A 2 x 32A

4 x 16A 2 x 32A

Weight

63kg

80kg

Input Voltage

230V

415V 3Ø

Output Voltage

110V

110V

IP Rating

IP44

IP44

10000/1PH and 10000/3PH

Power Splitter • • • •

110V Heavy duty steel case with carry handle Incorporates four 16A outlets Complete with 5m cable and 16A connector

Power Splitter PS45

Power splitter with cable

PS45 Product Code

PS45

Cable length

5m

Cable size

2.5mm

Plug

16A

Socket Outlets

4 x 16A

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

83


Cable Reels & Extension Leads Briticent’s Cable Reels offer an efficient portable power solution for sites with all reels incorporating an easy wind handle with rear grip. Reels are available in a durable open reel design in 25m lengths in 110V and 240V models. The 240V model incorporates 2 USB ports and a thermal cutout. Briticent’s Extension Leads provide a power distribution solution for a range of domestic, commercial and industrial applications. Available in both 110V and 240V models with 1.5mm or 2.5mm arctic grade cable, Briticent’s 16A 14 metre extension leads are ideal for site power requirements.

84

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Designed to withstand construction site conditions

Safety thermal cut-outs High visibility yellow cable and IP44 rated power connectors Heavy duty metal stand for ease of use with ergonomic grip handle

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

85


110V Cable Reels • • • • • • •

IP44

Suitable for use in a range of commercial and industrial applications 2 x 110V 16A dust covered outlet sockets Easy wind handle and rear grip Ergonomically designed Integrated power switch Easy wind handle and rear grip Includes thermal cutout

110V Cable Reels SE1030 SE1040

2g 16A 110V 25m 2g 16A 110V 50m

Product Code

SE1030

Length

25m

SE1030

SE1040 50m

Amp

16A

Cable Size

1.5mm

IP Rating

IP44

Voltage

110V

Max Load Unwound

1760W

Max Load Wound

770W

240V Cable Reels with USB • • • • • •

IP20

Suitable for use in a range of commercial and industrial applications 2 x 240V 13A outlet sockets Easy wind handle Includes 2 USB ports Optimised design for increased cable capacity Includes thermal cutout

240V Cable Reels with USB SE2010

86

2g 13A 240V 25m

Product Code

SE2010

Length

25m

Amp

13A

Cable Size

1.25mm

IP Rating

IP20

Voltage

240V

Max Load Unwound

3120W

Max Load Wound

960W

USB

2 ports

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

SE2010

|

w: deta.co.uk


• • • •

IP44

Suitable for commercial and industrial applications Fitted with plug and coupler Couplers supplied with dust covers Made with highly durable arctic grade cable

87

110V Extension Leads SE3010 SE3030

1.5mm 16A 110V 14m 2.5mm 16A 110V 14m

SE3010

SE3030

240V Extension Leads • • • •

Cable Reels Reels and Leads

110V Extension Leads

IP44

Suitable for commercial and industrial applications Fitted with plug and coupler Couplers supplied with dust covers Made with highly durable arctic grade cable

240V Extension Leads SE3020 SE3040

SE3020

1.5mm 16A 240V 14m 2.5mm 16A 240V 14m

SE3040

110V H-Frame Extension Leads • • • • •

IP44

Suitable for use in a range of commercial and industrial applications H-frame provides an easy storage solution Couplers supplied with dust covers Ergonomically designed Made with highly durable arctic grade cable

H-frame extension lead SE3050 SE3070

1.5mm 16A 110V 14m 2.5mm 16A 110V 25m

SE3090 SE3110

2.5mm 32A 110V 14m 2.5mm 32A 110V 25m

Product Code

SE3010

SE3030

SE3110

SE3020

SE3040

Length

14m

14m

Amp

16A

16A

Cable Size

1.5mm

2.5mm

1.5mm

SE3050

SE3070

SE3090

14m

25m

14m

25m

16A 2.5mm

SE3110

32A

1.5mm

2.5mm

IP Rating

IP44

IP44

IP44 110V

Voltage

110V

240V

Max Load Unwound

1760W

3120W

1760W

3520W

Max Load Wound

770W

1200W

770W

1100W

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

87


Festoon Lighting & Power Briticent’s Festoon Lighting & Power range provides an ideal temporary lighting solution for use on construction sites. A number of festoon lighting kits are available including 20m and 44m integrated LED IP65 kits, as well as 22m LED replacement lamp kits with B22 or E27 lamp holders. Festoon lighting accessories include 100m festoon cable, replacement LED lamps, and polycarbonate festoon guards. Festoon power cable is also offered for applications where site works cover a large area, eliminating the need for multiple extension leads.

88

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


High visibility yellow cable for construction site use

IP65 rating for total protection against dust and low pressure

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

89


Festoon Lighting Kit - Integrated LED • • • • •

Suitable temporary lighting solution for indoor and outdoor use Complete 20m kit with 7 fully integrated LED lamps 0.75mm cable Lamps spaced every 2m Supplied with 16A plug

Festoon Lighting Kit - Integrated LED SEFLKITINT

7 x 10W 6500K IP65 20m

Product Code

SEFLKITINT

Wattage

7 x 10W

Lumens

1,200 Lm

IP Rating

IP65 (Lamp) IP44 (Connector)

Colour Temperature

6500K

Beam Angle

120°

Voltage

110V

Rated life (Hours)

30,000

Lamp Spacing

2m

SEFLKITINT

Festoon Lighting Kit • • • • •

44m kit with fully integrated LED lamps 15x10W lamps spaced every 3m 1m lead-in from plug to first lamp 0.75mm cable Supplied with 16A 110V plug

Festoon Lighting Kit BI2113

15 x 10W 6500K IP65 44m

BI2113 Product Code

90

BI2113

Wattage

15x10W

Lumens

2,550 Lm

IP Rating

IP65 (Lamp) IP44 (Connector)

Colour Temperature

6500K

Beam Angle

120°

Voltage

110V (50-60Hz)

Rated life (Hours)

15,000

Lamp Spacing

3m

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

IP65


• • • • • • •

IP44

Suitable temporary lighting solution for indoor and outdoor use Complete 22m kit with 10 lamps and 10 guards Arctic grade 2.5mm cable Lampholders spaced every 2m Available with Halogen or LED GLS lamps Available as B22 or E27 Supplied with 16A plug

Festoon Lighti ngng Festoon Lighti

Festoon Lighting Kits

91

Festoon Lighting Kits - LED SEFLLEDBC SEFLLEDES

Product Code

10 x 8W B22 4000K IP44 22m 10 x 8W E27 4000K IP44 22m

SEFLLEDBC

SEFLKITES

SEFLLEDES

Wattage

10 x 60W

Lumens

700 Lm

IP Rating

IP44

Colour Temperature

2800K

Lamp Spacing

2m

Rated life (Hours)

30,000

Festoon Lighting Cable • • • • • •

IP44

Suitable temporary lighting solution for indoor and outdoor use Can be used with Halogen or LED GLS lamp Arctic grade 2.5mm cable Comes with 33 lampholders, spaced every 3m Available as B22 or E27 Supplied with 3m lead and 16A plug

Festoon Lighting Cable SEFL13B SEFL13E

B22 IP44 100m E27 IP44 100m SEFL13

Product Code

SEFL13B

SEFL13E

IP Rating

IP44

Voltage

110V

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

91


Lamps & Accessories • • • • •

IP44

Lamps suitable for use with festoons, bulkheads and other 110V luminaires Polycarbonate wire guard for festoon kits LED lamps have a wide voltage range from 85-265V GLS lamps suitable for outdoor use All lamps have B22 or E27 option

LED GLS Lamps R1010 R1020

LED 8W E27 4000K LED 8W B22 4000K

R1010

Accessories SEPC

Festoon polycarbonate guard

SEPC

Product Code

R1010

Lamp Type

R1020 LED

Lamp Base

E27

Wattage

B22 8W

Lumens Impact Rating

IK03

IP Rating

92

Colour Temperature

4000K

Voltage

85-265V

Beam Angle

360

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

R1020


• • • •

IP44

Suitable power distribution solution for indoor and outdoor use 2.5mm 3-core 110V 100m main cable 1.5mm 3-core 110V 1m cable drop with 16A connector Power drops at 5m intervals

93

Festoon Power PR1005L

Product Code

16A 110V IP44

PR1005L

Drops

20

IP Rating

IP44

Voltage

110V

PR1005L

Festoon Power + Weatherproof Junction Box • • • • •

Festoon ng FestoonLighti Power

Festoon Power

IP44

Suitable power distribution solution for indoor and outdoor use 2.5mm 3-core 110V 100m main cable 1.5mm 3-core 110V 1m cable drop with 16A connector Power drops with rewireable square weather proof boxes at 5m or 10m intervals Single or dual power drops options

Single Power Drop with 10m Intervals BI2112

100m 10 x single power drop at 10m intervals

Dual Power Drop with 5m Intervals BI2121

100m 19 x dual power drop at 5m intervals BI2112

Product Code

BI2112

Drops

10 single

BI2121

BI2121 19 dual

IP Rating

IP44

Voltage

110V

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

93


LED Plasterers Lights Briticent’s LED Plasterers Lights are available in both 20W 2ft and 30W 5ft options with two 16A outlet connections included as standard for linkable functionality. Easy to store and transport, this IP65 range is supplied complete with a 5m power lead and a 16A 110V plug. The 2ft model is available in both A-frame and tripod formats whilst the 5ft tripod range includes an emergency option with patented manual override technology, allowing the 3-hour emergency feature to be overridden at the push of a button.

94

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Polycarbonate body and diffuser IP65 rating for total protection against dust and low pressure jets of water

Supplied with foldaway steel stand for ease of storage

LED range is an ideal replacement for a fluorescent plasterers light

Complete with 5m power lead and 16A 110V yellow plug

2 x 16A 110V outlet connections allow for multiple lights to be linked together

Unique emergency option with 5ft plasterers light

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

95


LED 2ft Plasterers Lights

IP65

P1000

P1010

LED 2ft Plasterers Lights

• •

P1000 P1010

• • •

2ft 20W 6300K IP65 A-frame 2ft 20W 6300K IP65 tripod

• • • •

Product Code

96

P1000

P1010

Wattage

20W

Lumens

2,200 Lm

Impact Rating

IK08

IP Rating

IP65

Colour Temperature

6300K

Voltage

100-277V

Beam Angle

120°

Rated life (Hours)

30,000

t: 0845 884 7000

|

Suitable lighting solution for working in confined spaces Supplied with foldaway stand for ease of storage and transportation Ideal replacement for fluorescent plasterers lights Wide voltage range 100V-277V / 50-60Hz Polycarbonate base with opal diffuser and steel stand, complete with LED tray IP65 fitting rating for total protection against dust and low pressure jets of water Supplied with two 16A outlet connections for linkable applications Complete with 5m power lead and 16A 110V yellow plug Operating temperature of -15°C to +50°C

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


ENERGY SAVING

IP65

LED Plasterers Lights

LED 5ft Plasterers Lights

97

P1020

P1025

LED 5ft Plasterers Lights

• •

P1020 P1025

• • •

5ft 30W 6300K IP65 tripod 5ft 30W 6300K IP65 tripod + EM

• • • •

Suitable lighting solution for working in confined spaces Supplied with foldaway stand for ease of storage and transportation Ideal replacement for fluorescent plasterers lights Wide voltage range 100V-277V / 50-60Hz Polycarbonate base with opal diffuser and steel stand, complete with LED tray IP65 fitting rating for total protection against dust and low pressure jets of water Supplied with two 16A outlet connections for linkable applications Complete with 5m power lead and 16A 110V yellow plug Operating temperature of -15°C to +50°C (non emergency)

Emergency • 3 hour emergency feature • Operating temperature of 0°C to +50°C • Patented manual override technology allows emergency feature to be overridden at the push of a button Product Code

P1020

P1025

Wattage

30W

Lumens

3,300 Lm

Impact Rating

IK08

IP Rating

IP65

Colour Temperature

6500K

Voltage

100-277V

Beam Angle

120°

Rated life (Hours)

30,000

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

97


LED Task Lights Briticent’s LED Task Lights offer a wide range of compact and portable 110V task lights for use on construction sites. The range includes linkable task lights and single and twin tripod mounted options.

98

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Suitable for a range of commercial and industrial applications Ideal replacement for a halogen task light Compact and portable with tripod options

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

99


REX Slim LED Task Light

S4010

IP65

S4110

• • • • • • •

REX Slim LED Task Light S4010

10W 4000K IP65

REX Slim LED Tripod Lights S4110 S4120

110V Suitable for a range of commercial and industrial applications Ideal replacement for halogen task lights Aluminium body with tempered glass diffuser Driver on board technology Complete with 1.5m power lead and 16A connector IP65 rating for total protection against dust and low pressure jets of water

10W 4000K IP65 2 x 10W 4000K IP65

Product Code

100

S4120

S4010

S4110

S4120

Wattage

10W

2 x 10W

Lumens

900 Lm

2 x 900 Lm

Impact Rating

IK07

IP Rating

IP65

Colour Temperature

4000K

Voltage

110V

Beam Angle

120°

Rated life (Hours)

30,000

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


LED Task Lights

LED Task Light - Heavy Duty

IP44

101

S3020

S3010

• • • • • •

LED Task Light - Heavy Duty S3010

S3030

24W 6000K IP44

110V Suitable for a range of commercial and industrial applications Ideal replacement for halogen task lights Die cast aluminium body with steel handles and a protective rubber trim Driver on board technology Complete with 3m power lead and 16A connector

LED Tripod Lights - Heavy Duty S3020 S3030

Product Code

24W 6000K IP44 2 x 24W 6000K IP44

S3010

S3020

S3030

Wattage

24W

2 x 24W

Lumens

2,000 Lm

2 x 2,000 Lm

Impact Rating

IK08

IP Rating

IP44

Colour Temperature

6000K

Voltage

110V

Beam Angle

90°

Rated life (Hours)

30,000

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

101


LED Task Light - Standard • • • • •

IP44

110V Suitable for a range of commercial and industrial applications Ideal replacement for halogen task lights Aluminium body with tempered glass diffuser Complete with 1.5m power lead and 16A connector

LED Task Light - Standard S3040

20W 6400K IP44

Product Code

S3040

Wattage

20W

Lumens

2,000 Lm

Impact Rating

IK07

IP Rating

IP44

Colour Temperature

6400K

Voltage

110V

Beam angle

120°

Rated life (Hours)

30,000

S3040

LED Task Light - Linkable • • • • • •

IP54

110V Suitable for a range of domestic and commercial applications Foldaway stand with carry handle and protective rubber trim High grade strength polycarbonate diffuser Linkable feature allowing task lights to be daisy chained together Complete with 3m power lead and 16A connector

LED Task Light - Linkable S2010

36W 6500K IP54

S2010 Product Code

102

S2010

Wattage

36W

Lumens

2,400 Lm

IP Rating

IP54

Colour Temperature

6500K

Voltage

110V

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


LED Task Lights 103

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

103


LED Bulkheads Briticent’s LED Bulkheads offer an ideal solution for the lighting requirements of a construction site including areas around scaffolding and other confined spaces. Standard, emergency and twin emergency options available.

104

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Suitable for a range of commercial and industrial applications

Emergency range available

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

105


LED Bulkheads

IP65

B2010

B2015

B2020

B2025

• • • • • • •

LED Bulkheads B2010 B2020

8W 6000K IP65 - opal 8W 6000K IP65 - red

LED Bulkheads - Pre-Wired B2015 B2025

106

Suitable for a range of commercial and industrial applications Grey polycarbonate body with red or opal diffuser options Integrated LED tray - no lamp required Suitable for 20mm cable entry with gland conduit Power terminals large enough for loop-in/loop-out connections Pre-wired option for quick installation available IP65 rating for total protection against dust and low pressure jets of water

8W 6000K IP65 - clear 8W 6000K IP65 - translucent red

Product Code

B2010

B2020

B2015

B2025

Finish

Opal

Red

Opal

Translucent Red

Voltage

100 - 277V

Wattage

8W

Lumens

640 Lm

Impact Rating

IK08

IP Rating

IP65

Colour Temperature

6000K

Beam Angle

120°

Rated life (Hours)

20,000

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


LED Bulkheads LED Bulkheads 107

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

107


LED Bulkhead - Emergency

IP65

E9600

• • • • • •

LED Bulkhead - Emergency E9600

3W 6000K IP65 EM

108

Product Code

E9600

Voltage

110V

Wattage

3W

Lumens

120 Lm

Impact Rating

IK04

IP Rating

IP65

Colour Temperature

6000K

Beam Angle

120°

Rated life (Hours)

35,000

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

Suitable for site, industrial and commercial applications Impact resistant polycarbonate diffuser and base Supplied maintained and can be wired non-maintained Constant light output when operating on mains or battery power 3 hour emergency function IP65 rating for total protection against dust and low pressure jets of water Supplied with legend stickers

w: deta.co.uk


IP65

1-YEAR GUARANTEE

LEDBulkheads LED Bulkheads

LED IP65 Twin Sport - Emergency

109

E9203

LED IP65 Twin Sport - Emergency E9203

2 x 7.5W 6000K IP65 EM

• • • • • • • • • •

Product Code

Suitable for site, industrial and commercial applications Ideal replacement for old style halogen twin spot fittings Non-maintained 3 hour battery duration Includes bi-colour LED indicator for manual inspection Tilt and pan heads allows light to be directed as required After 24 hour initial charge a full 3 hour test is performed automatically Self-test operation every 30 days for 52 weeks of the year Battery 9.6V 2200mAh Nickel Cadmium IP65 rating for total protection against dust and low pressure jets of water

E9603

Voltage

110V

Wattage

2 x 7.5W

Lumens

470 Lm

IP Rating

IP65

Colour Temperature

6000K

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

109


LED Inspection Lighting Briticent's LED Inspection Lighting range is designed to assist with lighting requirements in confined spaces and difficult to reach areas. The 110V and 240V LED Gripper Hand Lamp, for which Briticent has become well known for, offers a unique 360o portable lighting solution for inspection requirements on site.

110

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


• • • • • • • •

IP44

Robust handle made with rubber for high grip Detachable handle allows for magnetic mounting for handsfree use Fitted with hang up hook and magnetic base Supplied with 3m cable for flexibility LED lamp reduces heat when working in close proximity On/off switch Beam angle of 360° for maximum light output IP44 rated

LED Inspecti on Lighti Inspecti on Lighti ng ng

LED Gripper Hand Lamp 360°

111

LED Gripper Hand Lamp - 110V BI6111

15W 6500K IP44

LED Gripper Hand Lamp - 240V BI6121

15W 6500K IP44 BI6111 / BI6121

Product Code

BI6111

Finish Plug Type

BI6121 Opal

16A

13A

Wattage

15W

Lumens

1,500 Lm

Impact Rating

IK08

IP Rating

IP44

Colour Temperature

6500K

Voltage Beam Angle

110V

240V 360°

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

111


Ancillaries Briticent’s Ancillaries range complements the site electrics range and includes a cable carrier and cordless kettles.

112

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


• • • •

Ancillaries Ancillaries

Cable Carrier Capable of carrying weight up to 50kg Unit weight up to 2.8kg Locking mechanism to prevent accidental closure Fold away for easy storage

113

Cable Carrier SPAXA

Cable carrier

Product Code

SPAXA

Unit weight

2.8kg

Size Closed

380 x 40 x 760mm

Size Open

340 x 340 x 760mm

SPAXA

Kettles • • • • •

Cordless white kettle 1.7l capacity Boil dry protection 110V supplied with 16A connector 240V supplied with 13A plug

Kettles SEK001 SEK002

110V 1.7L 240V 1.7L

SEK001

Product Code

SEK001

SEK002

Wattage

1200W

1200W

Plug

16A

13A

Voltage

110V AC

240V AC

t: 0845 884 7000

|

SEK002

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

113


Established in 1976, Channel is a leading manufacturer of emergency lighting and safety products and a key distributor of the UK’s leading brands of Fire Detection solutions. Renowned for the breadth and depth of their product categories, Channel have built a strong and loyal customer base driven by an excellence in technical and customer support. Following the acquisition of Channel in 2016, Deta has proudly continued to develop the Channel brand with innovative market leading offerings. In particular the exclusive SmartTest Emergency Lighting testing range and unique ‘End to End’ service have been well received within the industry, showcasing Channels unrivalled knowledge and expertise.

114

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Contents Emergency Lighting Commercial & Security Lighting Central Battery Units & Static Inverters Fire Alarms, Panels & Detectors Equality Act & Assistance Products Door Entry Systems The Knowledge

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

116 - 165 166 - 173 174 - 181 182 - 237 238 - 259 260 - 269 270 - 283

|

w: deta.co.uk

115


Emergency Lighting Channel’s Emergency Lighting offering provides a multitude of products that are both stylish and installer friendly, whilst not compromising on high performance and quality. Meeting the relevant standards and regulatory requirements, Channel’s emergency lighting range includes bulkheads, downlights, exit signs, and twinspots.

116

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Contents LED Bulkheads LED Exit Signage LED Twinspot LED Downlights Dali Emergency Lighting

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

120 - 127 128 - 137 138 - 143 144 - 151 152 - 165

|

w: deta.co.uk

117


SIMPLE IS SMARTER SmartTest

Emergency light remote testing at the touch of a button At Channel, we’re constantly working to give our customers the edge. With our unique system, any number of our compatible emergency lights can be individually tested with just one universal remote tester (Ref E/EM/RC), saving time and money:

Minimises Disruption No need to switch off local lighting circuit during monthly 5-second and annual 3-hour tests

No hanging around for test to finish Any faults indicated by flashing red LED

Easy Access Fitting tested from up to 7m

Saves time and money No need for a key switch

118

PRODUCT CODE

DESCRIPTION

E/EM/RC

Optional Remote Control

t: 0845 884 7000

|

e: | w: deta.co.uk e: sales.lfs@deta.co.uk sales@channelsafety.co.uk | w: channelsafety.co.uk


1 Point the Remote Tester at the compatible emergency fitting.

1 click for the monthly 5-second test

2 2 clicks for the Annual 3 hour test.

(One further click aborts test if necessary)

3 Any issues will be indicated by a flashing red LED until the fault is rectified and the light retested.

SmartTest

LOOK FOR THE SYMBOL

SmartTest is compatible with the following products:

Meteor Maxi™ LED

123

Brook 2

124

Alpine™

130

Alpine Slim

130

5-in-1 Emergency Exit Sign

134

Grove™ Twinspot - IP65

142

Azelio Surface

146

Azelio Recessed

147

SoHo

170

Milan Range

171SoHo

Get in touch today for a personal product demonstration or quotation

884 7000 | e: sales.lfs@deta.co.uk | w: deta.co.uk t: 0845 884 7000t: 0845 | e: sales@channelsafety.co.uk | w: channelsafety.co.uk

119


LED Bulkhead Channel’s extensive range of bulkheads all boast an aesthetically pleasing design and are multi-functional, suitable for both indoor and outdoor use. With a contractor and end user focus, the Channel bulkheads are easy to install and require minimal maintenance. With many of their products now supporting the Channel SmartTest technology, you’ll struggle to find a more comprehensive emergency bulkhead offering.

120

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

121


Meteor™ LED

LED

3W

52lm

IP65

0.36Kg

2-YEAR GUARANTEE

Maintained or non-maintained 3-hour emergency backup Hinged gear tray allows for easy installation Uses typically 80% less power than that of an 8W fluorescent Other accessories: Semi-recessing kit and diffuser with legend Easily converts into an attractive emergency exit sign with a blade and diffuser kit

136mm

• • • • •

SELF TEST

Photometric Spacing Data (1 Lux) Mounting height

230m m

2.5m

2.4

5.8

5.4

2.4

4m

1.0

4.9

5.2

1.0

E/PIC/ME/LED.BLADE - Bulkhead shown with Blade & Diffuser Kit

Product Code

Description

E/ME/M3/LED/IP65

Meteor low profile LED Bulkhead complete with 10 LED array, IP65 version

E/ME/M3/LED/IP65/ST

Meteor low profile IP65 LED Bulkhead complete with 10 LED array, self-test version

Accessories E/ME/LED/SRK/1

Meteor LED semi-recessing kit

E/PIC/ME/LED/PACK

Meteor LED sticker Pictogram Pack (AD, AL, AR, and AU) viewing distance 20m

E/PIC/ME/LED/BLADE

Meteor LED Blade and diffuser Kit (IP65 rating) Light fitting not included - Viewing distance 20m

Replacement Parts B/BATT/METEOR/LED

Meteor LED Battery (3 cell stick AA NiCd 0.Ah

Product Code

E/ME/M3/LED/IP65

E/ME/M3/LED/IP65/ST

Light Source

LED

Lumen Output

52Lm

Dimensions

Light – 100mm (W) x 260mm (L) X 61mm (D) Blade 8mm (W) x 230mm (L) x 136mm (D)

Cut out Dimensions

230mm (L) x 61mm (W)

Power Consumption

3W

Viewing Distance

24M - Blade

Material

Polycarbonate

Weight

0.36Kg

IP Rating

IP65

Compliance

122

t: 0845 884 7000

BS EN 605998-2-22 and other relevant standards

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


SmartTest

LED

PICTOGRAMS INCLUDED

5W

124lm

IP65

0.75Kg

3-YEAR GUARANTEE

LED Bulkheads

Meteor Maxi™ LED

160mm

123

320mm E/MM/BLADE • • • • •

Optional remote control facility Hinged gear tray allows for easy installation Uses typically 80% less power than that of an 8W fluorescent Maintained or non-maintained 3-hour emergency backup 31m viewing distance

Photometric Spacing Data (1 Lux) Mounting height 2.5m

3.5

3.25

6.6

6.5

4m

4.0

3.6

8.0

7.2

Product Code

Description

E/MM/M3/LED

Meteor Maxi LED 3 hour maintained emergency light C/W remote control facility

Accessories E/EM/RC

Optional Remote Control

E/BEZ/MM

Meteor Maxi semi-recessing Bezel

E/MM/BLADE

Meteor Maxi Blade Kit (IP65 rated, 31m viewing distance, full legend pack supplied)

E/PIC/ME/LED/PACK

Meteor Maxi Pictogram Pack (AD, AL, AR, and AU)

Replacement Parts B/BATT/MM Product Code

Meteor Maxi LED Battery 3.6V 1500mAH with connector E/MM/M3/LED

Light Source

LED

Lumen Output Dimensions

124Lm 110mm (W) X 352mm (L) X 64mm (D)

Cut out Dimensions

320mm (L) X 160mm (H)

Power Consumption

5W

Viewing Distance

31M - Blade

Material

Polycarbonate

Weight

0.75Kg

IP Rating Compliance

IP65 BS EN 605998-2-22 and other relevant standards

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

123


Brook 2

SELF TEST

SmartTest

Photometric Spacing Data (1 Lux)

• •

Mounting height

2.5m

2.6

7.7

8.9

2.9

4m

2.6

4.9

8.9

2.7

• •

LED

7.3W

210lm

IP65

0.95Kg

GUARANTEE

Now with increased light output Uses typically 80% less power than that of an 8W fluorescent Maintained or non-maintained with 3 hour emergency back up Available with remote control test function or Self-test function Other Accessories: Semi-recessing bezel

Product Code

Description

E/BK/M3/LED/2

Brook self contained, 3 hour maintained emergency LED light (Comes with remote control option)

E/BK/M3/LED/2/ST

Brook self contained, self-test 3 hour maintained emergency LED light

E/BEZ/BK/1

Brook semi-recessing bezel

E/PIC/ME/LED/PACK

Brook pictogram pack – AD/AL/AR/AU

E/EM/RC

Optional Remote Control

Replacement Parts B/BATT/BROOK/2

Brook battery – 3 cell NiCd

Product Code

E/BK/M3/LED/2

Light Source

E/BK/M3/LED/2/ST LED (20 in one unit)

Lumen Output

320lm - 210lm in emergency mode

Dimensions

115mm (W) 350mm (L) 75mm (D)

Cut out Dimensions

100mm – 337mm for bezel

Power Consumption

7.3W

Viewing Distance

NA

Material

Polycarbonate diffuser & body

Weight

0.95KG

IP Rating

IP65

Compliance

124

3-YEAR

t: 0845 884 7000

BS EN 60598-2-22 and other relevant standards

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


LED

3W

150lm

IP65

0.95Kg

2-YEAR GUARANTEE

LED Bulkheads

Solent

35 2m m

68mm

125

11 0m m

Photometric Spacing Data (1 Lux)

• •

Mounting height 2.5m

2.4

5.8

5.4

2.4

4m

1.0

4.9

5.2

1.0

• • •

Long Life LED technology Maintained or non-maintained 3-hour emergency backup Low environmental impact & running costs 16mm or 20mm conduit entry Other accessories: Semi recessing bezel

Product Code

Description

E/SOLENT/M3

Solent LED 3 hour maintained emergency light with pictogram pack

E/BEZ/SOL

Solent semi recessing bezel

B/BATT/SOL

Solent battery – 3.6V 1.5Ah NiCd

Product Code

E/SOLENT/M3

Light Source

White LED

Lumen Output Dimensions

150Lm 352mm (L) 110mm (W) 68mm (D)

Cut out Dimensions

NA

Power Consumption

3W

Viewing Distance

NA

Material

Polycarbonate construction

Weight

0.95Kg

IP Rating Compliance

IP65 BS EN 60598-1:2008 & other relevant standards

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

125


Stratos

PICTOGRAMS INCLUDED

LED

1-2W

129 522lm

High output

145mm

• • • • •

IP65

0.4Kg

3-YEAR GUARANTEE

Cold

Slave fittings for central batteries and static inverters Use’s typically 80% less power than that of a 8W fluorescent Maintained or non-maintained 3-hour emergency backup Easily converts into an attractive emergency exit sign with a blade and diffuser kit Slimline profile & contemporary design

260m m

145mm

Drop Down Blade Option

260mm

Product Code

Legend

E/STRATOS/24 E/STRATOS/50 E/STRATOS/110 E/STRATOS/230 E/STRATOS/M3 E/STRATOS/M3/2W E/STRATOS/HI E/STRATOS/COLD

Light Source

LED

Lumen Output Dimensions

145mm (W) 265mm (L) 40mm (D) NA

Power Consumption

1-2W

Viewing Distance

t: 0845 884 7000

Stratos 7x LED 1W IP65 24V AC/DC slave bulkhead c/w exit sign pictogram 198lm

E/STRATOS/50

Stratos 7x LED 1W IP65 50V AC/DC slave bulkhead c/w exit sign pictogram 198lm

E/STRATOS/110

Stratos 7x LED 1W IP65 110V AC/DC slave bulkhead c/w exit sign pictogram 198lm

E/STRATOS/230

Stratos 7x LED 1W IP65 230V AC/DC slave bulkhead c/w exit sign pictogram 198lm

E/STRATOS/M3

Stratos 7x LED 1W IP65 3 hour maintained bulkhead c/w exit sign pictogram 198lm – 129lm in emergency mode

E/STRATOS/M3/2W

Stratos 7x LED 2W IP65 3 hour maintained bulkhead c/w exit sign pictogram 235lm – 238lm in emergency mode

E/STRATOS/HI

Stratos high output 2x LED 5W (522lm)

E/STRATOS/COLD

Stratos for temp range -20c to +40c 214 LED/ 2W 210/250 V AC 50/60hz; 186/254 V DC

E/STRATOS/REC/KIT

Stratos semi recessing kit

E/STRATOS/PIC/KIT

Stratos hanging blade c/w exit sign pictogram

0.4Kg

IP Rating

126

E/STRATOS/24

NA

Weight

Compliance

Description

Accessories

129-522lm

Cut out Dimensions

Product Code

IP65 BS EN 60598-2-22 & other relevant standards

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


LED

18W

2Kg

1500lm

IP65

3-YEAR GUARANTEE

LED Bulkheads

Stratos Ultra

75 m m

338mm

127

168mm

Photometric Spacing Data (1 Lux)

3m

8.4

14.3

8.3

14.0

• • • •

6m

11.4

20.3

9.2

19.7

Mounting height

10m

11.3

20.6

11.1

20.1

15m

12.85

26.1

10.3

25.8

18m

13.1

31.4

12.6

27.3

Approximately 15X the light output of a typical bulkhead Long life LED technology Maintained or non-maintained operation Low environmental impact, low running costs and low maintenance Easy to install

Product Code

Description

E/STRATOS/ULTRA

Stratos Ultra – High output IP65 3 hour maintained bulkhead

Product Code

E/STRATOS/ULTRA

Light Source

42x SMD 2835 White LED

Lumen Output Dimensions

1500lm 388mm (L) 168mm (W) 75mm (D)

Cut out Dimensions

NA

Power Consumption

18W

Viewing Distance Material

NA Polycarbonate construction with clear diffuser

Weight

2Kg

IP Rating

IP65

Compliance

BS EN 60598-2-22 & other relevant standards

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

127


LED Exit signage 5-in-1 Exit sign Meeting all BS EN 60598-2-22 and other relevant standards, Channel's reputation for compliance excellence is evident within their exit sign portfolio. Offering a wide range of exit boxes and hanging signs, they also provide an option for all mounting requirement. Channel provides energy effiecent alternatives to the standard conventional fluorescent typically fittings.

128

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

129


Alpine Slim

SmartTest

PICTOGRAMS INCLUDED

• • • • • • • • • • • • • • • Product Code

Description

E/AL/M3/SL/RC

Alpine Slim LED exit sign c/w full legend set

E/EM/RC

Optional Remote Control

Alpine™

SmartTest

• • • • • • • • • • • • • • •

4W

LED

2.1W

Description Alpine LED exit sign (Comes complete with Arrow Up legend)

E/EM/RC

Optional Remote Control

Alpine pictogram – arrow down

E/PIC/AL/AL

Alpine pictogram – arrow left

E/PIC/AL/AR

Alpine pictogram – arrow right

Replacement Parts B/BATT/ALPINE

t: 0845 884 7000

Alpine battery – 3 cell NiCd

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

29m

0.95Kg

3-YEAR GUARANTEE

IP20

32m

0.8Kg

3-YEAR GUARANTEE

Dimensions: 210mm (H) 405mm (W) 55mm (D) Light source: LED Power consumption: 1.9W Uses typically 80% less power than that of an 8W fluorescent 1.9 LED equivalent to 8W fluorescent Material: White polycarbonate IP Rating: IP20 Maintained or non-maintained 3 hour emergency backup Viewing distance: 32m Compliance: BS EN 60598-2-22 and other relevant standards Incorporates remote control testing facility Allows testing without disruption Unit tests for seconds or 3 hours Universal remote control with approx range of 10m

E/AL/M3/LED

E/PIC/AL/AD

IP50

Dimensions: 185mm (H) 317mm (W) 29mm (D) IP Rating – IP20 Maintained or Non-maintained 3 hour emergency back-up 5 downward pointing LEDs to illuminate exit door. Low environmental impact Minimal maintenance Meets BS EN 60598-2-22 and other relevant standards Lightweight & easy to install Minimal maintenance Light Source – SMT LED 4W Incorporated remote control testing facility Incorporates remote control testing facility Allows testing without disruption Unit tests for seconds or 3 hours Universal remote control with approx range of 10m

Product Code

Additional Legends

130

LED


SELF TEST

LED

7.9Kg

IP20

80m

6Kg

LED Exit Signage

Alpine Large

434mm

131

m m .5 38

822mm

• • • • • • • • • • • •

Brushed Stainless Steel Housing 822mmW x 434mmH x 38.5mm deep IP20 Long life LED technology Maintained operation Metal body – Polycarbonate legend plate Self test technology Cable entry: rear, end & side of back box Low environmental impact Low running costs Low maintenance Meets BS EN 60598-2-22 and other relevant standards

Product Code

Description

E/ALPINE/LARGE

Alpine Large maintained self-test exit sign 80m viewing distance

E/AL/LEG/LARGE/AU

Alpine Large – legend – Arrow UP

E/AL/LEG/LARGE/AD

Alpine Large – legend – Arrow DOWN

E/AL/LEG/LARGE/AL

Alpine Large – legend – Arrow LEFT

E/AL/LEG/LARGE/AR

Alpine Large – legend – Arrow RIGHT

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

131


Exitor

LED

169mm

• • • • • • •

43m m

IP20

30m

3-YEAR GUARANTEE

Maintained or Non-maintained 3 hour emergency back-up Down light panel LEDs to illuminate exit door Low environmental impact Minimal maintenance Meets BS EN 60598-2-22 and other relevant standards Lightweight & easy to install, hinged cover Supplied with full legend set

325mm

Product Code

Description

E/EX/M3

EXITOR LED exit sign c/w full legend set

Betalux

3-YEAR GUARANTEE

• • • • •

132

0.69Kg

SP/BX/AD/ DG/EN

Self-luminous fitting meaning no electrical energy source required Vandal resistant, waterproof, explosion proof and incapable of generating sparks Lasts up to 20 years based on initial brightness option Single or double faced Having no wires it’s ideal for heritage sites, hotels, office buildings, theatres, restaurants, oil rigs, factories, plants and mines

Product Code

Description

SP/BX/AU/DG/EN

Self-powered Exit Sign c/w arrow up legend

SP/BX/AD/DG/EN

Self-powered Exit Sign c/w arrow down legend

SP/BX/AL/DG/EN

Self-powered Exit Sign c/w arrow left legend

SP/BX/AR/DG/EN

Self-powered Exit Sign c/w arrow right legend

SP/BX/AD/DG

Self-powered Exit Sign c/w arrow down legend – grey trim

SP/BX/AL/DG

Self-powered Exit Sign c/w arrow left legend – grey trim

SP/BX/AR/DG

Self-powered Exit Sign c/w arrow right legend – grey trim

Product Code

SP/BX/AU/ DG/EN

SP/BX/AL/ DG/EN

SP/BX/AR/ DG/EN

SP/BX/AD/ DG

Light Source

Betalux tubes manufactured from borosilicate glass and internally coated with zinc sulphide phosphor and filled with tritium gas.

Lumen Output

NA

Dimensions

218mm (H) X 396mm (W) X 28mm (D)

Cut out dimensions

NA

SP/BX/AL/ DG

Power Consumption

NA

Viewing Distance

30M

Material

Aluminium frame in polycarbonate window and borosilicate glass tubes. Cased in high impact ABS fire-retardant plastic

Weight

0.68kg

IP Rating

IP65

Compliance

BS5499-2

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

SP/BX/AR/ DG


PICTOGRAMS INCLUDED

LED

2W

IP20

28m

0.8Kg

3-YEAR GUARANTEE

290mm

LED Exit Signage

Razor™

133

Hanging lenth

160mm

up to 1m

360mm

• • • • • • • • • •

Light source: LED 2W Uses typically 80% less power than that of an 8W fluorescent Material: Polycarbonate / Aluminium IP Rating: IP20 Maintained 3 hour emergency backup Weight: 0.8Kg Compliance: BS EN 60598-2-22 and other relevant standards Viewing Distance 28 metres Comes complete with universal legend pack Comes with legend blank for single siding

E/RZ/M3/LED/H – Hanging

E/RZ/M3/LED/W – Wall/Ceiling

E/RZ/M3/LED/F – Recessed

E/RZ/M3/LED/R – Hanging Recessed

Product Code

Description

E/RZ/M3/LED/H

Razor 3 hour maintained LED exit sign hanging – Maintained only Comes complete with universal legend pack (arrows left/right, up/down, blank)

E/RZ/M3/LED/R

Razor 3 hour maintained LED exit sign hanging recessed – Maintained only Comes complete with universal legend pack (arrows left/right, up/down, blank)

E/RZ/M3/LED/F

Razor 3 hour maintained LED exit sign flush recessed – Maintained only Comes complete with universal legend pack (arrows left/right, up/down, blank)

E/RZ/M3/LED/W

Razor 3 hour maintained LED exit sign wall/ceiling fitting – Maintained Comes complete with universal legend pack (arrows left/right, up/down, blank)

Replacement Parts E/PIC/RZ/PACK

Razor pictogram Set

B/BATT/RAZOR/W

Battery for Razor (Wall only)

B/BATT/RAZOR/F/H/R

Battery Pack for Razor

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

133


5-in-1 Exit Sign

SmartTest

PICTOGRAMS INCLUDED

LED

3W

IP20

30m

0.8Kg

344mm

155mm

237mm

42 m m

1000mm max

Suspended

Flag

Ceiling

Recessed

• • • • • •

Wall

134

Maintained or Non-maintained 3 hour emergency back up Low Environmental Impact Minimal Maintenance Supplied with full legend set Unique remote control testing option 5 Mounting options Supplied as standard

Product Code

Description

E/5IN1

5-in-1 LED exit sign

E/EM/RC

Remote Control Test Unit

Product Code

E/5IN1

Battery

3.6V 1.5 Ah NiCd

Viewing Distance

30M

Mounting Options

Wall, Ceiling, Flag, Recessed, Suspended

IP Rating

IP20

Compliance

BS EN 605998-2-22 and other relevant standards

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

3-YEAR GUARANTEE


SELF TEST

• • • • • Adjustable up to 1m

LED

2.1W

IP40

28m

0.8Kg

3-YEAR GUARANTEE

Uses typically 80% less power than that of an 8W fluorescent Maintained 3 hour emergency backup Comes complete with universal legend pack Comes with legend blank for single siding Self test as standard

Product Code

LED Exit Signage

Forest

135

Description

Forest (Self-test complete with arrow up legend) E/CHFO/M3/L/WHST

3 hour maintained in white

E/CHFO/M3/L/BRST

3 hour maintained in brass

E/CHFO/M3/L/CHST

3 hour maintained in chrome

E/CHFO/M3/L/SAST

3 hour maintained in satin

54 m m

Additional Legends for Forest (insert only) S/LEG/FO/ALR

Double sided arrow left/right

S/LEG/FO/AD

Double sided arrow down

180mm

250mm

Mounting Brackets E/CHFO/WMB/SI

Satin Silver Wall Mounting Bracket

E/CHFO/WMB/WH

White Wall Mounting Bracket

E/CHFO/WMB/BR

Brass Wall Mounting Bracket

Flag Mounting Brackets

360mm Forest fitting showing arrow up

E/CHFO/FMB/SI

Satin flag mounting bracket

E/CHFO/FMB/WH

White silver flag mounting bracket

E/CHFO/FMB/BR

Brass flag mounting bracket

Replacement Parts Please contact Channel

Product Code Light Source

E/CHFO/M3/WHST

E/CHFO/M3/BRST

E/CHFO/M3/CHST

Viewing Distance

28M

Material

Polycarbonate/Aluminium

Weight

0.8Kg

IP Rating Compliance

E/CHFO/M3/SAST

LED 2W

IP40 BS EN 605998-2-22 and other relevant standards

Please note: The Forest fitting is supplied as standard with 1m hanging chain, fixing brackets are available.

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

135


Camber

SELF TEST

LED

3W

1.3Kg

IP20

30m

3-YEAR GUARANTEE

50% energy saving over conventional fluorescent Self-test versions available Comes complete with universal legend pack Maintained switchable and self-test versions available Comes with legend blank for single siding Simple first fix mounting bracket

193mm

251mm

• • • • • •

PICTOGRAMS INCLUDED

330mm Camber surface fitting

Camber hanging fitting Adjustable to 1 metre

Camber wall fitting

Product Code

Description

Camber – Comes complete with pictogram pack (arrows left/right, and up/down) E/CAMBER/WALL*

Wall Mounted Exit Sign 3hr Maintained

E/CAMBER/SURF*

Surface Exit Sign 3hr Maintained

E/CAMBER/HANG*

Hanging Exit Sign 3hr Maintained

Replacement Parts B/BATT/CAMBER

Battery for Camber

Product Code

E/CAMBER/WALL*

E/CAMBER/SURF*

Light Source

LED SMD3528

Power Consumption

4W

Viewing Distance

30M

Material

Polycarbonate housing

Weight

1.3Kg

IP Rating

IP20

Compliance

BS EN 605998-2-22 and other relevant standards

*Product self test version available. Add ‘/ST’ at end of product code.

136

E/CAMBER/HANG*

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


SELF TEST

LED

Product Code

2.1W

IP20

32m

1.5Kg

3-YEAR GUARANTEE

Description

Vale (Self-test complete with legend arrow up) E/CHVL/M3/L/WHST

Vale LED 3 hour maintained white

E/CHVL/M3/L/BRST

Vale LED 3 hour maintained brass

E/CHVL/M3/L/CHST

Vale LED 3 hour maintained chrome

LED Exit Signage

Vale

137

Additional Legends (insert only) Vale fitting showing arrow up • • • •

Uses typically 80% less power than that of an 8W fluorescent Self test as standard Can be switched internally to maintained or non-maintained operation Other accessories: Double sided pictograms available

Dale

S/LEG/VL/ALR

Double sided pictograms arrow left/right

S/LEG/VL/AD

Double sided pictograms arrow down

Replacement Parts B/BATT/DA/FO/VL/NIHM

SELF TEST

LED

2.1W

• • • •

Battery for Vale – NiHM New style 2 cell

IP20

32m

1.0Kg

3-YEAR GUARANTEE

Uses typically 80% less power than that of an 8W fluorescent Self test as standard Can be switched internally to maintained or non-maintained operation Other accessories: Pictograms available Product Code

Description

Dale 3 hr maintained self-test complete with arrow up legend

E/DA/M3/LED/3/ST Additional Legends

Dale fitting showing arrow up

S/LEG/DA/AL/3

Pictogram arrow left

S/LEG/DA/AR/3

Pictogram arrow right

S/LEG/DA/AD/3

Pictogram arrow down

Replacement Parts B/BATT/DA/FO/VL/NIHM

Product Code Dimensions Cut out Dimensions

E/CHVL/M3/L/WHST

E/CHVL/M3/L/WHST

Battery for dale – NiMH

E/CHVL/M3/L/WHST

E/DA/M3/LED/3/ST 175mm (H) 335mm (W) 38mm (D)

230mm (H) 355mm (W) 115mm (D) 335mm(L) 95mm (W) 60mm (D)

Light Source

LED

Power Consumption

2.1W

Viewing Distance

32M

N/A

Material

White, brass and chrome

White mild steel

Weight

1.5Kg

1.0Kg

IP Rating

IP20

Compliance

BS EN 605998-2-22 and other relevant standards

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

137


LED Twinspot Grove Ultra Channel's commitment to continually improving It's product offering has seen them invest heavily in their emergency lighting range. The recent Introduction of the ultrahigh output twinspot fitting, Grove Ultra Is a perfect example of this. It delivers 1800lm output with maintained and non-maintained operation. It Is easy to instal with cable entry at the rear, end and side of the fitting. It can also be mounted In any orientation. Channel twinspots are available In either IP20 or IP65 ratings.

138

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

139


Grove IP20

LED

• •

15W

15 LED’s per head Uses only 50% of the power than that of a tungsten halogen

• •

720lm

IP20

1.89Kg

3-YEAR GUARANTEE

Improved lumen output from the previous generation of the Grove range, now 720lm Low maintenance

Product Code

Description

E/GR/NM3/LED/2

Grove Twin 15 x LED floodlight, 3 hour non-maintained white lamps

B/BATT/GROVE/3

9.6V Battery pack for Grove

Photometric Spacing Data (1 Lux) Mounting height 4m

4.4 – 4.0m – 9.0m

13.2m

6m

4.7m – 5.2m – 10.8m

15.0m

8m

6.2m – 6.6m – 12.2m

17.0m

Grove IP65

SELF TEST

SmartTest

LED

15W

720lm

IP65

1.85Kg

3-YEAR GUARANTEE

Product Code

Description

E/GR/NM3/LED/IP65/RC

Grove Twin 2 x LED floodlight 3 hour non-maintained with white lamps RC test version

E/GR/NM3/LED/IP65/2/ST

Grove Twin 2 x LED floodlight 3 hour non-maintained with white lamps self-test version

E/EM/RC

Optional Remote Control

B/BATT/GROVE/3

9.6V Battery pack for Grove

Photometric Spacing Data (1 Lux) Mounting height • • • •

15 LED’s per head Uses only 50% of the power than that of a tungsten halogen Improved lumen output from the previous generation of the Grove range, now 720lm Low maintenance Product Code

4m

4.4 – 4.0m – 9.0m

13.2m

6m

4.7m – 5.2m – 10.8m

15.0m

8m

6.2m – 6.6m – 12.2m

17.0m

E/GR/NM3/LED/IP65/RC

Light Source

LED

Lumen Output

720Lm 285mm (H) X 280mm (W) X 75mm (D)

Dimensions Cut out Dimensions

NA

Power Consumption

15W

Viewing Distance

NA

Material

Polycarbonate

E/GR/NM3/LED/2

260mm (H) X 300mm (W) X 70mm (D)

Weight

1.85Kg

1.89Kg

IP Rating

IP65

IP20

Compliance 140

E/GR/NM3/LED/IP65/2/ ST

t: 0845 884 7000

BS EN 605998-2-22 and other relevant standards

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


LED

1800lm

18W

IP65

2.4Kg

3-YEAR GUARANTEE

LED Twinspot

Grove Ultra

285mm

141

• • • • • • • • •

Long life LED technology May be mounted in any orientation Easy to install with cable entry at rear, end and side of fitting Low environmental impact Low running costs Low maintenance Ideal for high mounting levels 18000Lm output allow high risk task emergency illuminations Mainted/Non-Maintained

73 m m

284 mm

Photometric Spacing Data (1 Lux) Mounting height 1800Lm

10m

12m

36m

25m

1800Lm

15m

12m

30m

28m

1800Lm

18m

12m

23m

29m

Product Code

Description

E/GR/M3/ULTRA

Grove Ultra self-contained 3 hour maintained emergency LED light

Product Code

E/GR/M3/ULTRA

Light Source

LED

Lumen Output

1800lm

Dimensions

285mm (H) X 284mm (W) X 73mm (D)

Cut out dimensions

NA

Power Consumption

18W

Viewing Distance

NA

Material

Polycarbonate

Weight

2.40kg

IP Rating

IP65

Compliance

BS EN 60598-2-22 and other relevant standards

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

141


GU32 - IP65 Twinspot

368lm

1.08Kg

3W

LED

IP65

2-YEAR GUARANTEE

68 m m

279mm

1m included

292mm

Product Code

Description

E/GU32/IP65

IP65 3 hour Non-maintained emergency twinflood

• • • • • • •

Photometric Spacing Data (1 Lux) Mounting height

Transverse to wall

Square Spacing

Axial to wall (front)

Axial to wall (rear)

2.5m

2.5

6.6

5

2.7

4m

2.7

8.7

6

2.9

2.5m

3.4

10

7.2

3

4m

4.3

11.2

8

4

Product Code

142

Excellent luminaire spacings Only 3W power consumption Minimal maintenance Easy installation May be mounted in any orientation Carrying handle for portability C/W 1m hanging kit

E/GU32/IP65

Light Source

LED

Lumen Output

368lm

Dimensions

279mm (H) X 292mm (W) X 68mm (D)

Cut out dimensions

NA

Power Consumption

3W

Viewing Distance

NA

Material

Polycarbonate

Weight

1.08kg

IP Rating

IP65

Compliance

BS EN 60598-2-22 and other relevant standards

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


368lm

• • • • •

LED

3.2W

1.2Kg

IP20

2-YEAR GUARANTEE

Long life LED technology Can be mounted in any orientation Easy to install with cable entry at rear, end and side of fitting Low environmental impact Low running costs

LED Twinspot

GU 32

143

310mm

Photometric Spacing Data (1 Lux) Mounting height 3.0m

8.5m

3.5m

10.5m

6m

4.0m

11.5m

70 m m

280m m

2.5m 4m

Product Code

Description

E/GU32

3 hour Non-maintained emergency twinflood

Product Code

E/GU32

Light Source

SMT LED 2 x 30pcs

Lumen Output

368lm

Dimensions

279mm (H) X 292mm (W) X 68mm (D)

Cut out dimensions

NA

Power Consumption

3.2W

Viewing Distance

NA

Material

Polycarbonate

Weight

1.2kg

IP Rating

IP20

Compliance

BS EN 60598-2-22 and other relevant standards

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

143


LED Downlight With several emergency downlight options available, Channel offers a diverse selection to cater for any requirement. The Glen 3W with LiFePO4 battery is the most recent addition to this range. It comes with the option of different finishes with replacement bezels and offers substantial energy and maintenance savings. With a simple 'plug and go' Installation It Is rapidly becoming the contractors go to emergency downlight.

144

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

145


Azelio Surface

LED

Twin Lens

SmartTest

137 150lm

3W

150mm dia

• •

40mm

• • • • •

0.95Kg

Corridor Lens 50 mm dia

Product Code

Description

E/AZELIO/S/RC

Surface mounted emergency downlight comes with open area and corridor lenses

E/EM/RC

Remote Control Test Unit (Optional)

E/AZELIO/S/ST

Surface mounted emergency downlight, comes with open area & corridor lenses with self test

Photometric Spacing Data (1 Lux) Mounting height 2.4m

4.50

3.40

9.25

7.40

4.50

3.40

4.50

3.40

3.0m

4.70

3.65

10.10

8.60

10.10

8.60

4.70

3.65

4.0m

4.60

3.45

9.80

8.40

9.80

8.40

4.60

3.45

Lux

0.5

1

0.5

1

0.5

1

0.5

1

4.80

4.50

14.45

13.50

8.83

5.80

Azelio Surface Corridor Photometric Spacing Data (1 Lux) Mounting height 2.4m

3.25

2.20

3.0m

2.35

2.15

4.65

4.40

13.90

13.10

7.60

6.70

4.0m

3.00

2.50

5.50

3.80

16.60

16.00

9.00

7.20

Lux

0.5

1

0.5

1

0.5

1

0.5

1

Product Code

E/AZELIO/S/RC

E/AZELIO/S/ST

Light Source

LED

Lumen Output

150lm (Open Area) and 137lm (Corridor)

Dimensions

150mm diameter X 40mm depth

Cut out dimensions

NA

Power Consumption

3W

Viewing Distance

NA

Material

Polycarbonate housing

Weight

0.95kg

IP Rating

IP20

Compliance

RoHS compliant

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

3-YEAR GUARANTEE

Versatile multi-functional use (escape and open are anti-panic) Supplied with both open area and corridor lenses Suitable for surface mounting Minimal maintenance Easy installation BESA box fitting Excellent luminaire spacings of up to 15m for corridor version

Azelio Surface Open Area

146

IP20


SELF TEST

LED

143 158lm

3W

Twin Lens

IP20

0.67Kg

3-YEAR GUARANTEE

147

85mm dia.

50mm Lense plate dia.

SmartTest

LED Downlights

Azelio Recessed

Corridor Lens •

Open Area Lens

Azelio Recessed Open Area

• •

Photometric Spacing Data (1 Lux)

Versatile multi-functional use (escape and open are anti-panic) Supplied with both open area and corridor lenses Suitable for recessed mounting Minimal maintenance

• • •

Easy installation Auto self-test or RC versions available Excellent luminaire spacings of up to 15m for corridor version

Mounting height 2.4m

n/a

3.75

n/a

8.25

n/a

13.00

n/a

6.50

Lux

0.5

1

0.5

1

0.5

1

0.5

1

Azelio Recessed Corridor Photometric Spacing Data (1 Lux) Mounting height 2.4m

n/a

2.10

n/a

4.20

n/a

13.00

n/a

6.50

Lux

0.5

1

0.5

1

0.5

1

0.5

1

Product Code

Description

E/AZELIO/R/COA/ST

Recessed 3W auto self test emergency downlight. c/w open area & corridor lens

E/AZELIO/R/RC

Recessed 3W non-maintained emergency downlight c/w open & corridor lenses & remote control option

E/EM/RC

Remote control test unit (Optional)

Product Code

E/AZELIO/R/COA/ST

E/AZELIO/R/RC

Light Source

LED

Lumen Output

158lm (Open Area) and 143lm (Corridor)

Dimensions

85mm diameter X 50mm lens plate diameter

Cut out dimensions

70-75mm

Power Consumption

3W

Viewing Distance

NA

Material

Polycarbonate housing

Weight

0.67kg

IP Rating

IP20

Compliance

RoHS compliant

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

147


Azelio Downlight

LED

Twin Lens

158 176lm

3W

0.28Kg

IP20

3-YEAR GUARANTEE

108mm

80mm

Open Area option • • 110mm Cut Out 95-100mm

Extension Bezel to

Corridor option

Pre-wired for east installation High output LED light source = less fittings Integrated long life lithium battery

• • • •

165mm dia

Built in ‘push to test’ switch 6000k-7000k Non-maintained Ideal size to replace existing downlight

Product Code

Description

E/AZELIO/COA

Azelio emergency LED downlight non-maintained C/W open are and corridor lenses

E/AZELIO/BEZEL

Azelio Bezel to expand the bezel size to 165mm

Azelio - Corridor Photometric Spacing Data (1 Lux) Mounting height 2.4m

n/a

6.50

n/a

13.00

n/a

4.20

n/a

2.10

3.0m

n/a

7.50

n/a

15.00

n/a

4.50

n/a

2.25

4.0m

n/a

9.00

n/a

18.00

n/a

5.00

n/a

2.50

Lux

0.5

1

0.5

1

0.5

1

0.5

1

Azelio - Open Area Photometric Spacing Data (1 Lux) Mounting height 2.4m

n/a

3.75

n/a

8.25

n/a

8.25

n/a

3.75

3.0m

n/a

4.00

n/a

8.50

n/a

8.50

n/a

4.00

4.0m

n/a

4.12

n/a

9.25

n/a

9.25

n/a

4.125

Lux

0.5

1

0.5

1

0.5

1

0.5

1

Product Code

E/AZELIO/COA

Light Source

LED

Lumen Output

158lm (Open Area) and 176lm (Corridor)

Dimensions

See diagram

Cut out dimensions

95-100mm

Power Consumption

3W

Viewing Distance

NA

Material

Polycarbonate housing

Weight

0.28kg

IP Rating

IP20

Compliance 148

E/AZELIO/BEZEL

t: 0845 884 7000

RoHS compliant

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


SELF TEST

• • • •

5W

LED

IP20

150lm

0.32Kg

3-YEAR GUARANTEE

Self-test as standard Maintained and non-maintained Self-test LED light source

LED Downlights

Ceilo

149

Photometric Spacing Data (1 Lux) Mounting height 2.5m

3.0

5.8

4m

3.45

6.4

Product Code

Description

E/CEILO/LED/ST

Ceilo downlight 5W, maintained and non-maintained self-test version

Glade

1/5W

LED

• • • • •

5W

1W

0.25/ 0.78Kg

60 415lm

IP40

3-YEAR GUARANTEE

Long life LED technology Maintained or non-maintained 3-hour emergency back-up Slimline driver module with sleek and minimalistic design Simple plug and go installation Low maintenance and low environmental impact

Product Code

Description

E/GL/LED/NM3/1W/WH

Glade 1W non-maintained LED mini downlight – white

E/GL/LED/M3/5W/WH

Glade 5W maintained LED mini downlight - white

Glade 5W

Glade 1W

Photometric Spacing Data (1 Lux)

Photometric Spacing Data (1 Lux)

Mounting height

Mounting height

2.5m

5.70

4.50

10.70

9.00

10.70

9.00

5.70

4.50

2.5m

2.4

5.8

5.4

2.4

4.0m

7.40

5.10

14.20

10.10

14.20

10.10

7.40

5.10

4m

1.0

4.9

5.2

1.0

6.0m

8.10

5.80

13.70

11.0

13.70

11.60

8.10

5.80

Lux

0.5

1

0.5

1

0.5

1

0.5

1

Product Code

E/CEILO/LED/ST

E/GL/LED/NM3/1W/WH

Light Source

E/GL/LED/M3/5W/WH

LED

Lumen Output

150Lm

60-145Lm

Dimensions

50mm (D) 25mm (H)

44mm (D) 34mm (H)

70mm (D) 60mm(H)

Cut out Dimensions

40mm

35-38mm

60mm

Power Consumption

5W

1W

5W

Viewing Distance

NA

Material

Aluminium housing

Weight

0.32Kg

IP Rating

IP20

Compliance

0.25Kg

0.78Kg IP40

BS EN 60598-2-22 and all other relevant standards and regulation

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

149


Glen LED Downlight

Module

LiFePo4 Battery

22mm

Mounting height 2.8m

3.5

7.1

4m

3.1

6.4

Description

E/GLEN/3W

Glen 3W non-maintained downlight C/W white bezel

E/GLEN/BEZ/BK

Glen Black Bezel – Pack of five

E/GLEN/BEZ/SI

Glen Silver Bezel – Pack of five

E/GLEN/3W

Light Source

LED

Lumen Output

103.22lm

Dimensions

See diagram

Cut out dimensions

NA

Power Consumption

3W

Viewing Distance

NA

Material

Polycarbonate/metal construction

Weight

0.25kg

IP Rating

IP20

Compliance

BS EN 60598-2-22

|

0.25Kg

IP20

3-YEAR GUARANTEE

LiFePO4 long life battery Simple plug and go installation Low environmental impact Beam angle 120 degree Colour temperature 55ook Non-maintained operation 3 hours emergency back-up

Product Code

t: 0845 884 7000

103.22lm

Photometric Spacing Data (1 Lux)

Product Code

150

• • • • • •

27mm

150mm

3W

White

40mm(Ø)

Silver

30mm(Ø)

Black

LED

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


LED Downlight 151

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

151


i-Monitor DALI Emergency Light Testing System

• • • • • • • • • • • • •

App based Emergency Light testing system Simple emergency duration & function test scheduling System diagnostic information Control Hubs connect up to 128 DALI lights I-Pad can control 10 hubs (1280 DALI lights) Simple menu navigation Records results & sends notification emails Scalable to 10,240 DALI Lights Air print compatible Master i-Pad can control 10 hubs Each hub has 2 outputs Up to 8 x iPads can be networked giving a total of 10,240 DALI lights iPad can be moved to log on to any hub with a wireless access point, or additional iPads can be used

i-Monitor PRO DALI Lighting Control & Emergency Light Test The i-Monitor Pro uses a PC or laptop for the control & monitoring of the system. It is simply linked to any Multi-Controller. Featuring an intuitive graphic user interface and commissioning tool, coupled with a very powerful database engine, the system provides an intuitive and simple way to initially set-up the system, as well as presentation of live real time status. A wide range of sensors, switch input interfaces and scene button panel options ensure market leading functionality and flexibility.

Product Code

3-YEAR GUARANTEE

System Architecture The i-Monitor PRO offers a solution for Commercial applications such as offices, schools, universities, hotels, airports etc. The simple display provides clear and concise visualisation of the lighting control scheme. Unlimited control groups, system Diagnostics, alert messages power consumption data, & emergency light test reports further enhance the benefits of the system. The Monitor Pro software can be used to configure any connected DALI device to form local control groups. DALI devices do not need to be physically in the same DALI field network to function as part of a control group. Thus a control group can be as simple as a single switch controlling one local light, right up to say, a switch controlling the whole building. The i-Monitor PRO offers a sophisticated lighting control & emergency light monitoring system. Any DALI type 8 light can be monitored & controlled.

Multi Controller Each Multi-Controller can control 10 hubs. Each hub has 2 outputs. Each output can control 64 lights (128 per hub) 128 x 10 hubs= 1280 lights. The i-Monitor Pro uses a simple graphical display designed to provide clear and simple visualisation and management of lighting control systems. Icons representing system elements can be overlaid on building schematics and incorporated into a site plan. These icons are dynamic and allow the state of the system and current output levels to be viewed at a glance giving a real-time system wide view.

Description

I-Monitor network & control Equipment

152

LBEM/TOUCH/ETHERNET

I-Pad with POE ethernet access point. i-Monitor software pre-loaded

EHUB-2DALI-ENC1

I-Monitor Emergency Enclosure containing 1 DALI Hub - 5 Port unmanaged network switch included. Enclosure dimensions 300W x 300H x 90D

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


• • • • • • •

PART CODE E/ID/MESH/WORKS

PART CODE E/ID/MESH/HUB

• • • •

Each iD-Mesh hub can control up to 239 lights Multiple –iD-Mesh hubs can be used to create systems WITH NO LIMIT ON SIZE ID-Mesh hubs have a range of up to 500m line of sight and up to 100m within a building The iD-Mesh wireless nodes can be fitted in to any suitable DALI emergency light Each hub reports to the cloud platform which can be viewed at any location via a web browser The nodes have an approximate range of 50m The mesh technology enables all nodes to both receive & transmit data to the hub, this ensures that signals have multiple paths to/from the node Persistent gateways mean that if communication is lost, data is stored until communication is re-established. Transmits at Long Range 868Mhz Commissioning & system changes are carried out using an “iDMesh Works” robust tablet The iD-Mesh Works tablet builds the mesh at the push of a button

Dali Emergency Lighting

iD Mesh Wireless DALI emergency lighting testing system

153

Including the gateway, the maximum for each mesh is 240 points

Product Code

Description

I-Monitor Pro Network & control Equipment MCONTROLLER/ENC

Monitor Multi-Controller.Each Multi-controller can manage upto 10 DALi hubs.Enclosure Dimensions 300Wx300Hx90D

MPC/PRO

A Dell Vostro or Equivalent tower PC with Screen, Keyboard, mouse and Monitor Pro Software preinstalled

EHUB-2DALI-ENC1

Emergency Enclosure containing 1 DALI Hub - 5 Port unmanaged network switch included. Enclosure dimensions 300W x 300H x 90D

To find out more information on our iD Mesh Fittings, please contact a member of our sales team on 0845 884 7000 or email customerservices@channelsafety.co.uk

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

153


DALI Recessed Exit Sign

SELF TEST

• • • • • •

25m

LED

5W

IP41

1.1Kg

Extra long life liFePO4 cells Recessed Mounting ISO legends as standard DDP (Deep discharge protection) Samsung LED’s i-Monitor or iD-MESH Wireless options available

E/EXDA/1

Product Code

Description

E/EXDA/1/**

DALI Maintained/Non-Maintained Recessed mounted LED Exit sign-White ** add AU, AD, ALR

E/EXDA/1/ID/**

DALI Wireless Maintained/Non-Maintained Recessed mounted LED Exit sign-White ** add AU, AD, ALR

Product Code

154

E/EXDA/1/**

E/EXDA/1/ID/**

Light Source

LED

Lumen Output

NA

Dimensions

328mm W x 200mm H x 62mm D

Cut out dimensions

300mm x 42mm

Power Consumption

44mA

Viewing Distance

25M

Material

White polycarbonate body, translucent polycarbonate cover

Weight

1.1Kg

IP Rating

IP41

Compliance

BS EN 60598-1 & 2

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

3-YEAR GUARANTEE


25m

LED

3W

0.95Kg

IP41

3-YEAR GUARANTEE

Dali Emergency Lighting

DALI Surface Exit Sign

155 • • • • • •

Extra long life liFePO4 cells Surface Mount – Wall or ceiling ISO legends as standard DDP (Deep discharge protection) Samsung LED’s i-Monitor or iD-MESH Wireless options available

E/EXDA/2

Product Code

Description

E/EXDA/2/**

DALI Maintained/Non-Maintained surface mounted LED Blade Exit sign-White ** add AU, AD, ALR

E/EXDA/2/ID/**

DALI Wireless Maintained/Non-Maintained surface mounted LED Blade Exit sign-White ** add AU, AD, ALR

Product Code

E/EXDA/2/**

E/EXDA/2/ID/**

Light Source

LED

Lumen Output

NA

Dimensions

300mm x 200mm x 42mm

Cut out dimensions

NA

Power Consumption

40mA

Viewing Distance

25M

Material

White polycarbonate body, translucent polycarbonate cover

Weight

0.95Kg

IP Rating

IP41

Compliance

BS EN 60598-1 & 2

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

155


DALI Suspended Exit Sign

• • • • • •

SELF TEST

25m

LED

5W

IP40

1.46Kg

3-YEAR GUARANTEE

Extra long life liFePO4 cells Suspension Mounting ISO legends as standard DDP (Deep discharge protection) Samsung LED’s i-Monitor or iD-MESH Wireless options available

E/EXDA/3

Product Code

Description

E/EXDA/3/**

DALI Maintained/Non-Maintained Suspended mounted LED Exit sign-White ** add AU, AD, AL, AR

E/EXDA/3/ID/**

DALI Wireless Maintained/Non-Maintained Suspended mounted LED Exit sign-White ** add AU, AD, AL, AR

Product Code

E/EXDA/3/**

E/EXDA/3/ID/**

Light Source

LED

Lumen Output

NA

Dimensions

156

Blade 335mm x 187 mm x 20mm

Base 230mm x 37mm x70mm (plus 750mm suspension)

Cut out dimensions

NA

Power Consumption

55mA

Viewing Distance

30M

Material

White polycarbonate body, translucent polycarbonate cover

Weight

1.46Kg

IP Rating

IP40

Compliance

BS EN 60598-1 & 2

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


25m

LED

3W

0.95Kg

IP65

3-YEAR GUARANTEE

Dali Emergency Lighting

DALI Exit Sign

157 • • • • • •

Extra long life liFePO4 cells Surface Mounting – optional recessed mounting ISO legends as standard DDP (Deep discharge protection) Samsung LED’s i-Monitor or iD-MESH Wireless options available

E/EXDA/4

Product Code

Description

E/EXDA/4

DALI emergency Maintained/Non-Maintained IP65 3W exit sign c/w full legend pack

E/EXDA/4/ID

DALI Wireless emergency Maintained/Non-Maintained IP65 3W exit sign c/w full legend pack

Product Code

E/EXDA/4

E/EXDA/4/ID

Light Source

LED

Lumen Output

NA

Dimensions

276 mm x 143 mm x 44mm

Cut out dimensions

256 mm x 123mm

Power Consumption

55mA

Viewing Distance

25M

Material

White polycarbonate body, translucent polycarbonate cover

Weight

0.95Kg

IP Rating

IP65

Compliance

BS EN 60598-1 & 2

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

157


DALI Wall Mounted Exit Sign

SELF TEST

• • • • • •

30m

LED

5W

IP40

1.43Kg

Extra long life liFePO4 cells Surface Mount - Wall ISO legends as standard DDP (Deep discharge protection) Samsung LED’s i-Monitor or iD-MESH Wireless options available

E/EXDA/5

Product Code

Description

E/EXDA/5

DALI Maintained/Non-Maintained Wall mounted LED Exit sign-White c/w full legend pack

E/EXDA/5/ID

DALI Wireless Maintained/Non-Maintained Wall mounted LED Exit sign-White c/w full legend pack

Product Code

E/EXDA/5

E/EXDA/5/ID

Light Source

158

LED

Lumen Output

NA

Dimensions

335mm x 187 mm x 44mm

Cut out dimensions

300mm x 150mm

Power Consumption

55mA

Viewing Distance

30M

Material

White polycarbonate body, translucent polycarbonate cover

Weight

1.43Kg

IP Rating

IP40

Compliance

BS EN 60598-1 & 2

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

3-YEAR GUARANTEE


LED

3W

241 / 250lm

IP20

3-YEAR GUARANTEE

Dali Emergency Lighting

DALI Circular Emergency Downlight

159 • • • • • •

Extra long life liFePO4 cells Surface Mounting – optional recessed mounting ISO legends as standard DDP (Deep discharge protection) Samsung LED’s i-Monitor or iD-MESH Wireless options available

E/DLDA/1

Product Code

Description

E/DLDA/1/**

DALI 3W Circular LED surface mounted **add open or corridor lens OA/CO

E/DLDA/1/ID/**

DALI Wireless 3W Circular LED surface mounted **add open or corridor lens OA/CO

Product Code

E/DLDA/1/**

E/DLDA/1/ID/**

Light Source

LED

Lumen Output

OA= 250Lm CO= 241Lm

Dimensions

155mm DIA 58mm deep

Cut out dimensions

NA

Power Consumption

18mA when charged

Viewing Distance

25M

Material

White polycarbonate body, translucent polycarbonate cover

Weight

0.39Kg

IP Rating

IP20

Compliance

BS EN 60598-1 & 2

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

159


DALI Square Emergency Downlight

• • • • • • •

LED

3W

241 / 250lm

Extra long life liFePO4 cells Open area Or Corridor lens options Non-Maintained Operation Besa Box and Standard Fixing Points Deep Discharge Protection Extra Long Life LiFePO4 Batteries DALI 1 Device Registered With DiiA

E/DLDA/2

Product Code

Description

E/DLDA/2/**

DALI 3W Square LED surface mounted **add open or corridor lens OA/CO

E/DLDA/2/ID/**

DALI Wireless 3W Square LED surface mounted **add open or corridor lens OA/CO

Product Code

160

E/DLDA/2/**

E/DLDA/2/ID/**

Light Source

LED

Lumen Output

OA= 250Lm CO= 241Lm

Dimensions

155mm DIA 58mm deep

Power Consumption

55mA

Weight

0.42Kg

IP Rating

IP20

Compliance

BS EN 60598-1 & 2

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

IP20

3-YEAR GUARANTEE


LED

241 / 250lm

3W

3-YEAR GUARANTEE

Dali Emergency Lighting

DALI Recessed Downlight

161 • • • • • • •

Extra long life liFePO4 cells Open area Or Corridor lens options Suitable for Ceiling Recess Applications Deep Discharge Protection Plugs and Leads for Simple Installation Extra Long Life LiFePO4 Batteries DALI 1 Device Registered With DiiA

E/DLDA/3

Product Code

Description

E/DLDA/3/**

DALI 3W LED emergency downlight-recessed ** add OA, CO

E/DLDA/3/ID/**

DALI Wireless 3W LED emergency downlight-recessed ** add OA, CO

Product Code

E/DLDA/3/**

E/DLDA/3/ID/**

Light Source

LED

Lumen Output

OA= 224Lm CO= 232Lm

Dimensions

Module dimensions (LxWxH) 164 x 35 x 28mm Battery Dimensions (Lx Ø) 100m 34mm

Cut out dimensions

Approx. 43mm

Power Consumption

44mA

Weight

0.28Kg

IP Rating

IP54

Compliance

BS EN 60598-1 & 2

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk 161


DALI Bulkhead

LED

• • • • • • • •

Extra long life liFePO4 cells Surface Mount (Wall or Ceiling) Optional Recessed (Wall or Ceiling) White Polycarbonate body Translucent Polycarbonate Cover Ingress Rating - IP65 DDP (Deep Discharge Protection) Samsung LED's

E/BHDA/2

Product Code

Description

E/BHDA/2

DALI 3W IP65 bulkhead

E/BHDA/2/ID

DALI Wireless 3W IP65 bulkhead

Product Code

E/BHDA/2

E/BHDA/2/ID

Light Source

162

LED

Lumen Output

245Lm

Dimensions

276mm x 143 mm x 44mm

Cut out dimensions

Approx 256 mm x 123mm

Power Consumption

40mA

Viewing Distance

30M

Material

White polycarbonate body, translucent polycarbonate cover

Weight

0.75Kg

IP Rating

IP65

Compliance

BS EN 60598-1 & 2

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

3-YEAR GUARANTEE


LED

3-YEAR GUARANTEE

Dali Emergency Lighting

DALI Twinspot

163

• • • • • • •

610 lumen Output High Capacity NiCd cells Easy Installation Deep Discharge Protection High Efficiency Low Maintenance Lightweight Construction

E/TSDA/1

Product Code

Description

E/TSDA/1

DALI IP65 6W LED Twinspot emergency providing 610 lumen output

E/TSDA/1/ID

DALI Wireless IP65 6W LED Twinspot emergency providing 610 lumen output

Product Code Light Source

E/TSDA/1

E/TSDA/1 LED

Lumen Output

610Lm

Dimensions

300mm x 280 mm x 95mm

Power Consumption

44mA

Weight

2.05Kg

IP Rating

IP65

Compliance

BS EN 60598-1 & 2

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

163


DALI Ceiling Light

LED

• • • • • • •

Extra long life liFePO4 cells 20W mains output 3 hour-maintained emergency White polycarbonate base and high light transmission polycarbonate diffuser Lumen output: 2100Lm/287Lm Instant start, long life with low maintenance Meets BS EN 60598-2-22

E/SOHO/M3/DA

Product Code

Description

E/SOHO/M3/DA

DALI Soho 21W maintained ceiling light

E/SOHO/M3/DA/ID

DALI Wireless Soho 21W maintained ceiling light

Product Code

164

E/SOHO/M3/DA

E/SOHO/M3/DA/ID

Light Source

LED

Lumen Output

Maintained 2100Lm - 287Lm Emergency Output

Dimensions

325mm DIA 134mm deep

Power Consumption

104mA

Weight

1.45Kg

IP Rating

IP65

Compliance

BS EN 60598-1 & 2

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

3-YEAR GUARANTEE


Dali Emergency Lighting 165

165

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

165


Commercial & Security Lighting Channel’s continuous improvement methodology has seen their already popular ranges within their LED luminaires developed further, with the addition of corridor function and the SmartTest option. Within their Hazardous Area Lighting offering, Channel’s explosion proof Commando range now comes in three different sizes with optional wall mounting brackets available. The Commando is available in a number of wattage options ranging from 22W-136W.

166

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Contents LED Luminaires Hazardous Area Lighting

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

168 - 171 172 - 173

|

w: deta.co.uk

167


LED Luminaires The Channel LED Luminaires offer includes the elegantly designed SoHo and Milan ranges. These already popular ranges have both been enhanced further with the introduction of the SmartTest function. Both ranges additionally offer three colour temperatures with 3000K, 4200K and 6000K options available. Already popular with contractors because of their easy installation and interior and exterior use, these ranges now come with added appeal.

168

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

169


SoHo

SELF TEST

K

LED

SmartTest

3x Options

21W

2100lm

IP65

1.45Kg

3-YEAR GUARANTEE

Our Soho and Milan ranges are now with corridor function, three colour temperature selection & remote control option • The CorridorFUNCTION enures that light is produced only when actually needed This saves energy usage & possible light polution • When the person leaves the corridor/room, a presence detector will dim the light after a preset period. After a further preset period, if no movement is detected the light will switch off completely • When a person enters a corridor or room, the light will come on/ increase to full brightness • The light also incorporates a daylight sensor so it only illuminates if the ambient light is below a pre-set level

• • • •

Selectable 3 colour temperature – options 3000K, 4200K & 6000K May be mounted in any orientation Typical power saving: 35-40% over conventional 2D luminaires Mains or emergency 3 hour maintained

The setting available are: Distance (sensitivity) setting – The detector has a maximum range of 10M. Distance detected range can be adjusted to 100%, 75%, 50% & 0% of the maximum range (approx 6m radius mounted at 3m height).

Stand-By Period (corridor function) – This is the time period the light will remain at the dimmer light level. Once the chosen time has elapsed the light will turn off. This can be over ridden so the light remains at the dimmed level until movement is detected.

Hold Time Setting – The ‘Hold time’ is the period the lamp remains at 100% once movement has ceased. The sensor can be adjusted to 5s, 30s, 60s, 5min, 10min, 20min and 30min.

Stand-by Dimming Level – This is the level the light dims to once movement has ceased & the hold time setting has elapsed, this can be set to 10%, 20%, 30% or 50% of the full light level. Choice of three colour temperatures, 3000k, 4200k & 6000k.

Daylight Setting – Day light value can be adjusted to 2 lux, 10 lux, 50 lux and disabled. If you choose ‘Disabled’ then the light will

• •

and microwave options available (with corridor function) Mains output 2100lm emergency output 287lm Remote Control emergency testing option

Photometric Spacing Data (1 Lux)

• • • •

Versatile multi-functional use, interior & exterior Mains only & Maintained emergency options Easy installation minimal maintenance IP65 ingress protection

Photometric Spacing Data Soho Mini (1 Lux) Mounting height

Mounting height 2.5m

4.3

10.0

10.0

4.3

2.5m

4.8

11.0

11.0

4.8

4m

4.8

11.4

11.4

4.8

4m

6.0

12.4

12.4

6.0

Product Code

Description

E/SOHO

Soho Led 20w Mains only Light

E/SOHO/M3

Soho Led 20w 3 Hour Maintained EMERGENCY Light

E/SOHO/MW

Soho Led 20w Mains only Light c/w Microwave Sensor

E/SOHO/M3/MW

Soho Led 20w 3 Hour Maintained EMERGENCY Light c/w Microwave Sensor

E/SOHO/M3/RC

Soho Led 20w 3 Hour Maintained EM Light With RC

E/SOHO/M3/MW/RC

Soho Led 20w 3 Hour Maintained EM Light c/w Microwave Sensor With RC

SP/SOHO/M3/ST

Soho Led 20w 3 Hour Maintained EMERGENCY Light - Self Test

SP/SOHO/M3/MW/ST

Soho Led 20w 3 Hour Maintained EMERGENCY Light c/w Microwave Sensor - Self Test

Product Code

E/SOHO

E/SOHO/ M3

E/SOHO/ MW

E/SOHO/ M3/MW

E/SOHO/ M3/RC

Light Source

LED

Lumen Output

2100Lm

Dimensions

325mm diameter

Cut out dimensions

N/A

Power Consumption

21W

Viewing Distance

N/A

Material

Polycarbonate

Weight

1.45Kg

IP Rating

IP65

Compliance 170

operate all the time no matter how bright the ambient light level is.

t: 0845 884 7000

Bs EN 60598-2-22

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

E/SOHO/ M3/MW/RC

SP/SOHO/ M3/ST

SP/SOHO/ M3/MW/ST


K

SmartTest

3x Options

15W

LED

IP65

1400lm

1.08Kg

3-YEAR GUARANTEE

Photometric Spacing Data (1 Lux) Black

171

Mounting height

Chrome

2.5m

4.3

10.0

10.0

4.3

4m

4.8

11.4

11.4

4.8

68mm

White

LED Luminaire

Milan LED Luminaire

305mm dia. Brass

Black eyelid

White eyelid

Product Code

Description

E/MILAN

Milan LED 15W mains only light

E/MILAN/M3

Milan LED 15W 3 hour maintained emergency light

E/MILAN/MW

Milan LED 15W mains only with microwave sensor light

E/MILAN/M3/MW

Milan LED 15W 3-hour maintained emergency with microwave sensor light

E/MILAN/M3/RC

Milan LED 15W 3-hour maintained emergency light with remote control

E/MILAN/M3/MW/RC

Milan LED 15W 3-hour maintained emergency with microwave sensor light with remote control

E/MILAN/BEZ/CH

Milan chrome bezel

E/MILAN/BEZ/BR

Milan brass bezel

E/MILAN/BEZ/BK

Milan black bezel

E/MILAN/EYE/WH

Milan white eyelid bezel

E/MILAN/EYE/BK

Milan black eyelid bezel

E/EM/RC

Remote Control

Product Code

E/MILAN

E/MILAN/ M3

E/MILAN/ MW

E/MILAN/ M3/MW

Light Source

LED

Lumen Output

1400Lm

Dimensions

305dia.

Cut out dimensions

N/A

Power Consumption

15W

Viewing Distance

N/A

Material

Polycarbonate

Weight

1.08Kg

IP Rating

IP65

Compliance

Bs EN 60598-2-22

t: 0845 884 7000

|

E/MILAN/ M3/RC

e: sales.lfs@deta.co.uk

E/MILAN/ M3/MW/RC

|

w: deta.co.uk

171


Commando Explosion Proof Hazardous Area • • • • • • • •

112W & 136W Commando EXP

Wall Mounting Bracket

22W & 36W

Eyelid

Commando EXP

47W & 68W

Hood

Commando EXP

LED

Delivered Lumen

Dimensions

22W

2,828lm

309 x 178 x 102mm Deep

37W

4,750lm

309 x 178 x 102mm Deep

47W

5,695lm

614 x 178 x 102mm Deep

68W

8,021lm

614 x 178 x 102mm Deep

112W

13,172lm

1247 x 178 x 102mm Deep

136W

15,930lm

1247 x 178 x 102mm Deep

IK10

3-YEAR GUARANTEE

Product Code

Description

E/COM/EXP/22W

Commando 22W 309mm long

E/COM/EXP/22W/EYE

Commando 22W Eyelid cover 309mm long

E/COM/EXP/22W/HOOD

Commando 22W Hood cover 309mm long

E/COM/EXP/37W

Commando 37W 309mm long

E/COM/EXP/37W/EYE

Commando 37W Eyelid cover 309mm long

E/COM/EXP/37W/HOOD

Commando 37W Hood cover 309mm long

E/COM/EXP/47W

Commando 47W 614mm long

E/COM/EXP/68W

Commando 68W 614mm long

E/COM/EXP/112W

Commando 122W 1247mm long

E/COM/EXP/136W

Commando 136W 1247mm long

E/COM/BKT/1

Commando wall bracket, 2 required for 112w and 136w

E/COM/ EXP/37W

E/COM/ EXP/47W

Lumen Output

2,828Lm

4,756Lm

Dimensions

309mm X 178mm X 102mm

Power Consumption

22W

E/COM/ EXP/68W

E/COM/ EXP/112W

E/COM/ EXP/136W

5,695Lm

8.021Lm

13,172Lm

15,930Lm

309mm X 178mm X 102mm

614mm X 178mm X 102mm

614mm X 178mm X 102mm

1247 X 178mm X 102mm

1247 X 178mm X 102mm

37W

47W

68W

112W

136W

LED

Viewing Distance

N/A

Material

CAST Aluminium & Polycarbonate

Weight

Available on application

IP Rating

IP67 – IK10

Compliance

Bs EN 60598-2-22

t: 0845 884 7000

IP67

Wattage

Light Source

172

K

4000

HAZARDOUS AREA range Robust, vandal resistant die cast aluminium body fittings Polycarbonate diffuser Certified to Class 1, Division 2 Explosion Proof Hazardous Location (ATEX Zone 2 Equivalent) Optional wall mounting brackets. Optional eyelid covers (22 & 37w) Operating Temperatures: -40°C to +40°C

E/COM/ EXP/22W

Product Code

22-136W

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Hazardous Area Lighting 173

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

173


Central Battery Units & Static Inverters Channel’s Central Battery Units (CBU) are bespoke designs with a comprehensive range of standard features with the addition of robust solutions to meet specific customer requirements. All can be supplied in wall mounted or free standing cabinets with the option of high ingress protection.

174

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Contents Mini Static Inverters Specialist Batteries NiCd Batteries

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

176 - 178 179 - 180 181

|

w: deta.co.uk

175


AC/DC Central Battery Units • • • • • • •

Bespoke designs Ventilated mild steel cabinets Maintained and Non-Maintained options available 12 / 24 / 36 / 48 / 50 / 110 / 220Vdc output options Extensive range of Slave Luminaires available Various back up runtimes to suit specifications Options for self-contained battery compartments

To find out more information on our AC/DC Central Battery Units, please contact a member of our sales team on 0845 884 7000 or email customerservices@channelsafety.co.uk

AC/DC Central Battery Slave Light Fittings

As the name implies a central battery emergency light is one where it’s power comes from one source. The central battery slave fittings do not have an integral battery but rely on the central battery to supply them. Central battery systems come in either maintained or nonmaintained. They must be wired in fire rated cables.

176 2

Stratos Slave Fittings The Stratos range of slave fittings offers a slimline profile in contemporary design. Each light is supplied with a legend pack as standard. Optional drop down exit blades and semi-recessing kits are available. (see page 16 for full details).

Product Code

Description

E/STRATOS/24

Stratos 7x LED – 1W, IP65, 24 V AC/DC slave bulkhead c/w exit sign pictogram (1W 198lm IP65)

E/STRATOS/50

Stratos 7x LED – 1W, IP65, 50 V AC/DC slave bulkhead c/w exit sign pictogram (1W 198lm IP65)

E/STRATOS/110

Stratos 7x LED – 1W, IP65, 110 V AC/DC slave bulkhead c/w exit sign pictogram (1W 198lm IP65)

E/STRATOS/230

Stratos 7x LED – 1W, IP65, 230 V AC/DC slave bulkhead c/w exit sign pictogram (1W 198lm IP65)

E/STRATOS/REC/KIT

Stratos Semi Recessing Kit

E/STRATOS/PIC/KIT

Stratos Hanging Blade legend c/w exit sign pictogram

t:t:0845 0845884 8847000 7000

|| e:e:sales.lfs@deta.co.uk | w: deta.co.uk sales@channelsafety.co.uk | w: channelsafety.co.uk


1-YEAR GUARANTEE

• • • • • •

C/STI-LED-200

Pure Sine Wave 32 bit Micro-controller Multi Fucntion LCD Display 3 Hour Duration Overload & Short Circuit Protection Compatible with optional remote hold off relays

Mini Static Inverters

Mini Static Inverters

3

C/STI-LED-400

Input Voltage

230V 50Hz +/- 10%

230V 50Hz +/- 10%

Input Current

<5.0A

<5.0A

Output Voltage

230V 50Hz +/- 10%

230V 50Hz +/- 10%

Output Regulation

1-5% dependent on load

1-5% dependent on load

Output Power

200W

400W

Output Capacity

120%

120%

No. of Maintained Outlets

1

1

Output

Pure Sine Wave

Pure Sine Wave

Battery type & capacity

SLA 12V/38AH

SLA 12V/38AH

Invertor H x W x D

305 x 472 x 66mm

305 x 472 x 66mm

Invertor weight

16.5Kg

16.5Kg

Battery cabinet H x W x D

1 x 238 x 472 x 174mm

2 x 238 x 472 x 174mm

Battery cabinet weight

34.5Kg

2 x 34.5Kg

Fixing locations

Wall or free standing

Wall or free standing

Product Code

Description

C/STI-LED-200

200 Watt LED Static Inverter

C/STI-LED-400

400 Watt LED Static Inverter

C/STI-LED-COR

Change over relay – used as hold off relay or as non maintained output.

To find out more information on our central battery & mini static inverters, please contact a member of our sales team on 0845 884 7000 or email customerservices@channelsafety.co.uk

t: 0845 7000 | e: sales.lfs@deta.co.uk | w: deta.co.uk t: 0845 884 7000 | 884 e: sales@channelsafety.co.uk | w: channelsafety.co.uk

1773


Static Inverters

1-YEAR GUARANTEE

• • •

• • • • •

No-break We manufacture a “No-Break” Emergency Lighting Static Inverter System that guarantees there will be no changeover switching of the supply to the load on mains failure. The load is totally unaffected by supply variation and is constantly fed with stabilised, smoothed and conditioned power.

Static inverter systems for emergency lighting

• •

Our Static Inverter Systems are able to provide the following input and output configurations: • • •

A totally integrated, energy efficient cost-effective and unobtrusive solution for all Emergency Lighting situations: • Passive Standby • Active Standby • No-Break for ALL lighting loads including high pressure discharge • All systems can be configured 1:1, 3:1 or 3:3 • Integration with our complementary products for Emergency Lighting • Optional output current limiters

Remote Alarm Panel – External panel for monitoring the static inverter Output Distribution – Internal distribution of the lighting circuits, standard in EL100XA & EL100, multiple outputs are optional Maintenance Bypass Panel – to provide flexibility during maintenance, service and/or repairs to the equipment. The bypass can ensure that the system is isolated from the critical load whilst work can be carried out Phase Failure Monitoring – Factory fitted relats to ensure that the system monitors all three phases. Failure of any phase activates the emergency lights. Sub-Circuit Monitoring – Factory Fitted relays monitor external lighting circuits, if any of the external circuits fail the emergency lights are activiated Lighting Control Interface – Allows communication via a node/ module to the testing and monitoring systems. Fire Alarm monitoring – An alarm condition from the fire alarm panel will activate the emergency lights Night-Watchmen Switch – Enables switching of the emergency lightsfrom a remote location, fail safe in an emergency condition Timer Control – Solar dials or 24hour timers can be used to activate the non-maintained contractor. Earth Fault Alarm – Monitoring of battery positive and negative for earth leakage.

Single Phase Input : Single Phase Output Three Phase Input : Single Phase Output Three Phase Input : Three Phase Output On Mains failure, the system converts DC power from the central battery to AC output. Our systems allow the use of our modern energy efficient luminaires, while our on-line ‘NO BREAK’ inverter systems enable the use of high-pressure discharge lighting.

Passive standby Our low cost flexible Passive Standby Static Inverter System is ideal for use with fluorescent and incandescent lighting sources. Traditional technology provides proven reliability with one of the lowest component counts in the industry. Low heat output, high efficiency (typically greater than 95% AC-AC). Conforms with all current relevant harmonised European standards.

Active standby “Active Standby” is our constantly running, off load, Static Inverter which can be monitored for function at all times – reassuring to know that the system will work when an emergency load is applied.

To find out more information on our Static Inverters, please contact a member of our sales team on 0845 884 7000 or email customerservices@channelsafety.co.uk

178

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


• •

In critical standby applications the battery can be a large integral part of the system and can also be an unpredictable element of the design Depending on models, batteries are either 3 to 5 year or 8 to 10 year design life. There are six key factors that can affect UPS battery life-the placement, ambient temperature, cycling, maintenance, battery chemistry and battery storage. It is important that sufficient maintenance is carried out to extend the life of your battery to the fullest

Specialist Batteries

Replacement Batteries

179

To find out more information on our replacement batteries, please contact a member of our sales team on 0845 884 7000 or email customerservices@channelsafety.co.uk

Small Office UPS • •

Channel Safety can offer a wide range of Small Office/Home Office related line interactive UPS products, designed to offer total power protection to a broad range of applications. Our PowerStar and PowerPrem+ ranges will provide clean and reliable backup power to ensure continued data integrity and optimum performance under a wide range of mains power conditions.

PowerStar – Line Interactive UPS Available from 650VA – 3kVA • Fully intelligent line interactive • Microprocessor based design • Overload protection • Boost & buck AVR voltage stabilisation

PowerPrem+ – Line Interactive UPS Available from 800VA – 5kVA • Microprocessor-based line interactive technology • Built-in boost and buck AVR • Tower and rackmount convertible design (1-3kVA) • Hot swappable battery design (1-3kVA)

PowerOn – Online Double Conversion UPS Available from 1kVA – 3kVA • Digital Signal Processor (DSP) technology • Tower and rackmount convertible design • Hot swappable battery design • Multiple communication ports

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

179


Sealed Lead Acid Batteries

• • • • •

Layout (see page 19)

Terminal Type

1 Second rate (Amps)

Impendance at 1kHz mOhms

Weight – typical (kg)

Height (over terminals) (± 2)

0.7

Width (± 1)

10-hr rate to 10.8V at 20°C (Ah)

0.8

Length (± 1)

20-hr rate to 10.5V at 20°C (Ah)

12

Dimensions (mm)

Watts per cell 10 min to 1.6VPC at 20 ° (watts)

Nominal Voltage (Volts)

Capacity

Superb recovery from deep discharge Electrolyte suspension system Gas recombination / Multipurpose: float or cyclic use Superior energy density / Visible status indication Lead calcium grids for extended life

Product Code B/12V/0.8AH/SLA

180

96

25

61.5

0.35

180

24

H

6

B/12V/1.2AH/SLA

12

1.2

1.1

97

48

54.5

0.58

110

36

A

3

B/12V/2.1AH/SLA

12

2.1

1.9

178

34

64

0.82

65

63

A

1

B/12V/2.3AH/SLA

12

2.3

2.1

178

34

64

0.95

65

69

A

1

B/12V/2.8AH/SLA

12

2.8

2.5

134

67

64

1.12

60

84

A

3

B/12V/3.2AH/SLA

12

3.2

2.9

134

67

64

1.2

50

96

A

3

B/12V/4AH/SLA

12

4.0

3.7

90

70

106

1.75

40

120

A/C

1

B/12V/7AH/SLA

12

7.0

6.4

151

65

97.5

2.65

23

210

A/C

4

B/12V/12AH/SLA

12

12.0

11.1

151

98

97.5

4.05

16

360

C

4

B/12V/17AH/SLA

12

17.0

15.7

181

76

167

6.1

15

510

D

2

B/12V/24AH/SLA

12

24.0

2.3

166

175

125

9

11

720

D

2

B/12V/38AH/SLA

12

38.0

5.3

197

165

170

14.2

9

1140

D

2

B/12V/65AH/SLA

12

65.0

0.5

350

166

174

23

7

1950

E

2

t: 0845 884 7000

|

Product Code

Description

B/12V/0.8AH/SLA

12 Volt 0.8Ah sealed lead acid battery (1 block)

B/12V/1.2AH/SLA

12 Volt 1.2Ah sealed lead acid battery (1 block)

B/12V/2.1AH/SLA

12 Volt 2.1Ah sealed lead acid battery (1 block)

B/12V/2.3AH/SLA

12 Volt 2.3Ah sealed lead acid battery (1 block)

B/12V/2.8AH/SLA

12 Volt 2.8Ah sealed lead acid battery (1 block)

B/12V/3.2AH/SLA

12 Volt 3.2Ah sealed lead acid battery (1 block)

B/12V/4AH/SLA

12 Volt 4Ah sealed lead acid battery (1 block)

B/12V/7AH/SLA

12 Volt 7Ah sealed lead acid battery (1 block)

B/12V/12AH/SLA

12 Volt 12Ah sealed lead acid battery (1 block)

B/12V/17AH/SLA

12 Volt 17Ah sealed lead acid battery (1 block)

B/12V/24AH/SLA

12 Volt 24Ah sealed lead acid battery (1 block)

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


• • • • • • • • •

NiCd Batteries

NiCd Batteries Available exclusively from channel safety systems High quality 4.0Ah nickel cadmium batteries Complete with connector and lead 1.2V per cell 55°C high temperature Dimensions: Each cell 33mm(Ø) x 60mmL (approx) Weight: 0.125 Kg per cell Compliance: IEC 61951 – 2003 Clause 7.4.2.3 Endurance test – 3rd party certified

Charge conditions

181

Dimensions per cell Time

Temp

Charge (mA)

Diameter (mm)

32.5 +/- 0.5

Standard

16hrs

0-45˚C

400mA (0.1C)

Height (mm)

59 +/- 1.0

Trickle

24hrs

0-70˚C

200mA (0.05C)

Weight (g)

125 approx.

Maintenance

0-55˚C

200mA (0.05C)

Electrical characteristics per cell

B

Nominal Voltage (V)

1.20

Nominal Capacity (mAh) @ 25˚C

4000

Maximum Continuous Discharge Current (A)

2.4

C

D

E

F

G

H

I

Storage Storage Temperature

0 to +25˚C

120 100 80 60 40 20 0

Charge efficiency after different charge rates Charge: 0.1°C x 15hrs 10°C 55°C 70°C

0

2

4

6 8 10 Charge duration (hours)

12

14

Capacity (%)

Standard charge characteristics Voltage (V) Capacity retainment (%)

Standard charge characteristics 1.6 1.5 1.4 1.3 1.2 1.1 1.0

16

120 100 80 60 40 20 0

No.1 No.2 Charge: 0.1°C (No.1) Charge: 0.25°C (No.2) Discharge: 0.25°C to 1.0V

-20

-10

0

10

Charge: 0.5°C Charge: 0.25°C to 1.0V Temp: 55°C

0

4

8

12

16 24 28 32 36 Number of months

Battery configurations

40

60

70

80

Discharge characteristics

Voltage (V)

Charge change in permanent charge

20 30 40 50 Cell temperatures (°C)

44

48

52

1.5 1.4 1.3 1.2 1.1 1.0 0.9

0.5°C

0

20

40

0.2°C

60 80 100 Charge duration (hours)

Product Code

Description

A

B/1.2V/4AH/NICD

NiCd 4.0Ah High Temperature D Cell Tags

120

140

B

B/2.4V/4AH/NICD

NiCd 2 Cell 4.0Ah High Temperature D Cell Leads

C

B/2.4V/4AH/NICD/S

NiCd 2 Cell 4.0Ah High Temperature D Cell Leads Side-By-Side

D

B/3.6V/4AH/NICD

NiCd 3 Cell 4.0Ah High Temperature D Cell Leads

E

B/3.6V/4AH/NICD/S

NiCd 3 Cell 4.0Ah High Temperature D Cell Leads Side-By-Side NiCd 4 Cell 4.0Ah High Temperature D Cell Leads

F

B/4.8V/4AH/NICD

G

B/4.8V/4AH/NICD/S

NiCd 4 Cell 4.0Ah High Temperature D Cell Leads Side-By-Side

H

B/6V/4AH/NICD

NiCd 5 Cell 4.0Ah High Temperature D Cell Leads

I

B/6V/4AH/NICD/S

NiCd 5 Cell 4.0Ah High Temperature D Cell Lead Side-By-side

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

181


Fire Alarms, Panels & Detectors Channel is proud to work with all of the fire industries leading manufacturers, giving them the capability to provide practical solutions to any fire installation. Offering a unique design to commissioning service, provided by their skilled and experienced designers, which supports the entirety of your project.

182

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Contents Site Alarms BS 5839-6 HUSH ActiV 4 Wire Conventional System 2 Wire Conventional System Analogue Addressable Systems Analogue Addressable Devices Wireless Analogue Addressable Devices Aspirating Equipment Automatic Opening Vent System Fire System Accessories Maintenance Test Equipment

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

186 - 187 188 - 191 192 - 197 198 - 203 204 - 215 216 - 217 218 - 223 224 - 225 226 - 227 228 - 233 234 - 237

|

w: deta.co.uk

183


SCALE-UP SAFETY End-To-End

Whatever the project, our unique End-To-End installer service gives you the confidence to deliver. Design within 48 hours of site visit

Site visits booked within 24 hours of request

(For emergency Lighting Schemes, Fire or Nurse Call Systems & Access Systems)

Quotation via your local Channel Stockist Partner ‘4-eyed Principle’*

1

2

3

Commissioning service booked within 24 hours of request

Technical advice and support available

Next day delivery on orders placed up to 4pm Via your local Channel Stockist Partner

(Chargeable)

6

5

4

*4-Eyed Principle: on all designs are checked by second person to ensure design integrity and safety

184

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Case Study

When Decathlon appointed Frederick Thomas Electrical & Maintenance Ltd to install a state-of-the-art fire detection system with refuge alarm in their new, purpose-built 257,000 sq ft logistics hub in Northampton, the firm took advantage of Channel’s unique End-To-End service to enable them to deliver.

Project Specs

• Work on the project began February 2018 • Initial meeting with Fredrick Thomas to look at the specification and formulate what level of design required • Equipment selected to give the best coverage and fastest response times • System design and drawings • Addition of Refuge Alarm, PA/VA (throughout the building) and disabled WC alarm. • Site visits throughout the installation to iron out any snags • Technical support • Commissioning and handover

“Co-operation and technical expertise are at the heart of our business, which is why we at Frederick Thomas Electrical & Maintenance Ltd value the partnership with Channel. From site design through to completion, their End-To-End service meant we were able to deliver a significant, complex project with total confidence.” Derrick Charlesworth, Frederick Thomas Electrical & Maintenance Ltd

“Channel End-To-End takes the unbeatable service our customers know us for to the next level. From design to delivery, we trust Channel to get the job done.” Gary Thompson, Medlock Electrical Distributors

No need to sub-contract your fire installs ever again. Simply get in touch to discuss your project

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

185


Temporary Site Alarms Site Master Wired Standalone/Linked System • • • • • • • • • •

F/CHEV/BGU

F/CHEV/PB

Operated by a Manual Call Point Complete with reset Key and resettable Membrane Easily installed and requires no external wiring Link products using two core cable Integrated high power flashing strobe Extremely loud 118dB sounder Powered by 9V PP3 battery Optional Call Point Cover Can be linked to other Evacuator products Manufactured in the UK

Product Code

Description

F/CHEV/BGU

Stand alone break glass call point fire alarm, 118Db sounder

F/CHEV/PB

Stand alone push button alarm, 118Db sounder

Evacuator Synergy - RF Wireless System • • • • • • • • • • •

Base Station

GSM Dialler

BGU Sounder Strobe

Sounder Strobe

Category 1 radio module 25mm Bright LED display unit Scratch resistant UV decals 85dB buzzer 40 Addressable zones Automatic battery low indication Completely wireless operation (No mains required) ‘Plug and play’ Simple Self Low maintenance costs Silent range test Battery Powered

Product Code

Description

F/CHEV/SYN/BS

Wireless Master unit with break glass call point 85Db sounder

F/CHEV/SYN/BGU

Wireless Break glass call point fire alarm, 108Db sounder & strobe

F/CHEV/SYN/SD

Wireless smoke detector 108Db sounder

F/CHEV/SYN/HD

Wireless heat detector, 108Db sounder

F/CHEV/SYN/SDWS

Wireless smoke detector with sounder, 108Db sounder

F/CHEV/SYN/SS

Wireless Sounder Strobe

F/CHEV/SYN/GSM

Wireless GSM Dialer

F/CHEV/SYN/INT2

Wireless relay interface

Smoke Detector

186

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Site Alarms 187

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

187


BS 5839-6 HUSH ActiV The HUSH ActiV Fire Alarm Solution provides reliable and fully monitored fire detection, alarm, silencing and test facilities in flats, apartments, and other dwellings. HUSH ActiV puts dwelling occupants firmly in control of their own life safety systems, allowing them to test fire detectors and silence false alarms whilst standing at floor level. In addition, it can be easily interfaced to other systems and equipment such as communal fire alarms and sprinkler monitoring amongst others.

188

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

189


HUSH ActiV

2-YEAR GUARANTEE

• • •

Includes all of the devices you need to create a typical LD2 dwelling system (additional ActiV detection and alarm devices available to accommodate larger systems or systems requiring LD1 coverage) Monitored for head removal, wiring, PSU and battery faults Attractive double gang Hush-ActiV controller comes with its own rechargeable 72-hour standby battery and separate mains power supply unit Uses attractively designed EN54 certified detection and alarm devices

Hush ActiV Benefits

F/C4403A2 60’C heat detector

F/C4414 Multi sensor

• • •

• Left F/C4416 Optical smoke detector

190

t: 0845 884 7000

|

F/BF431C/CC/W Base Sounder

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

Safer: Raises The Typical Level Of Fire Protection In A Dwelling From Bs 5839-6 Grade D (Unmonitored Mains/Battery Alarms) To Grade C (Monitored Wiring And A Central Controller) Easy-To-Access User Controls: No Need To Stand On A Chair To Test Or Hush/Silence Devices Secure Monitored Wiring: All Field Wiring Monitored For Open And Short Circuit Faults Environmentally Friendly: Up To 50% Reduction In The Mains Power Consumption Of A Typical Grade D System, Less Plastic And Only One Replaceable Lithium-Ion Battery Per System Providing Over 72 Hours’ Standby Reduced Lifetime Ownership Costs: Separate Fire Detectors And Sounders Are Less Expensive To Replace Than Mains/ Battery Alarms And All Smoke Detectors Have Built-In Drift Compensation To Increase Service Life Expectancy No Intrusive Bs 5839-1 Maintenance Visits: monthly User/ Occupant Test Is Sufficient Direct Grade D System Upgrades: Utilises The Same Wiring Scheme As Most Mains/Battery Alarm Solutions


BS 5839-6 Grade C Domestic Fire Alarm 191

F/CH/HAK/1 • • • • • • • •

F/CH/HAK/2

1 x Hush ActiV Controller 1 x 230V/24V 250mA PSU 1 x ActiV Multi Sensor Fire Detector 1 x ActiV Heat Detector 1 x ActiV Smoke Detector 3 x ActiV Detector Bases 1 x ActiV 96dBA Sounder 1 x ActiV Base Sounder Lid

• • • • • • •

F/CH/HAK/3

1 x Hush ActiV Controller 1 x 230V/24V 250mA PSU 1 x ActiV Heat Detector 1 x ActiV Smoke Detector 3 x ActiV Detector Bases 1 x ActiV 96dBA Sounder 1 x ActiV Base Sounder Lid

• • • • • • •

1 x Hush ActiV Controller 1 x 230V/24V 250mA PSU 1 x ActiV Multi Sensor Fire Detector 1 x ActiV Heat Detector 3 x ActiV Detector Bases 1 x ActiV 96dBA Sounder 1 x ActiV Base Sounder Lid

Hush-ActiV Hak/1 Kit Wiring 230V/24V 250mA PSU Mounts on a standard UK 35mm double gang back box Typical location: Adjacent to the dwelling’s Mains fusebox. 230V AC Supply

1-1.5mm2 standard triple + earth domestic electrical cable

1-1.5mm2 twin + earth electrical cable

ZONE +Ve Supply

Fault

Alarm

TEST

Hushed

HUSH

ZONE CIRCUIT

ActiV Multi Sensor (supplied)

ActiV Smoke Detector (supplied)

Optional Manual Call Point (not supplied)

EOL Capacitor

ActiV Heat Detector (supplied)

COMMON -Ve EOL Resistor

SNDR +Ve

HUSH-ACTIV CONTROLLER c/w 72 HOUR STAND-BY BATTERY Mounts on a standard UK 35mm double gang back box. Typical location: In the entrance way at light switch height so its controls are accessible to dwelling occupants.

ActiV Base Sounder (supplied)

Optional additional ActiV alarm devices (voice sounders & visual alarm devices also available)

S

SOUNDER CIRCUIT

Please note: HAK/2 and HAK/3 kits have a different mix of field devices. Component order on all kits can be changed to suit specific applications

Product Code

Description

F/C4403A1R

ActiV_Class A1R Rate-of-Rise Heat_Detector to EN54-5. Needs base

F/C4403A2

ActiV_Class A2 Standard (60ºC) Fixed Temp Heat_Detector to EN54-5. Needs base

F/C4416

ActiV_Optical Smoke_Detector to EN54-7. Needs base

F/C4414

ActiV_Multi-Sensor Fire_Detector to EN54-5/7. Needs base

F/C4408D

ActiV_Diode Base

F/BF431C/CC/W

ActiV Base mounted sounder -White

F/BF456C/CC/W

ActiV Base mounted sounder/beacon

F/CLOOM

Interface loom to link to other systems

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

191


4 Wire Conventional Scimitar Range The Scimitar 4 wire conventional fire alarm system has a range of control panels offering a flexible cost effective solution for conventional fire alarm systems. The Scimitar range comes with 2 zone, 4 zone and 8 zone options. All panels are LPCB certified to the latest versions of EN54 parts 2 and 4.

192

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

193


C-TEC Economy Fire Panels

3-YEAR GUARANTEE

• • • • • • • • •

Please note batteries are not included: 2, 4 & 8 Zone panels require 2x B/12V/3.2AH/SLA – listed below

Compatible Devices

• • • •

Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry to access level 2 Third-party certified to EN54-2/4 by the LPCB 2, 4 or 8 zone circuits (dependent on model purchased) Four conventional sounder circuits Integral 1.5A EN54-4/A2 compliant switch mode PSU Two open-collector outputs (Remote and Reset) ‘Class change’ and alert inputs Installer-friendly design accommodates easy first fix and straightforward maintenance Attractive flush or surface mountable plastic lid and enclosure – no bezel required Low quiescent current Multiple indicators End of line units included (one per zone) Requires 2 x B/12V/3.2AH/SLA batteries

Specification Construction

Polycarbonate enclosure

Beam devices

Enclosure Finish

RAL7035 Textured

C-TEC’s Economy panels are also compatible with Conventional Beam and Self adjusting beam devices – see page 92

Panel Dimensions

380mm (W) x 235mm(H) x 96mm(D) 2, 4 & 8 panels have the same measurements

Weight

1.75 Kg (without batteries)

Product Code

Description

Sounders & visual indicators See Pages 189 & 190

Detectors Apollo protocol Series 65 – see page 190

Panels

F/CHSC/2/E

CFP Economy 2 zone panel, keypad/ keyswitch entry, does not extend (requires 2 x B/12V/3.2AH/SLA battery)

F/CHSC/4/E

F/CHSC/4/E CFP Economy 4 zone panel, keypad/keyswitch entry, does not extend (requires 2 x B/12V/3.2AH/SLA battery)

F/CHSC/8/E

CFP Economy 8 zone panel, keypad/ keyswitch entry, does not extend (requires 2 x B/12V/3.2AH/SLA battery)

Call points Apollo protocol Series 65 – see page 189

Aspirating equipment Use in conjunction with Vesda Aspirating equipment on pages 88-89 to protect small businesses of less than 250m2 and 500m2

Please note: This panel does not have the functions to do the following: • • • • •

194

Delay zones or ouputs Set up coincidence between zones Make zones non latching Have volt free contacts for fire or fault. You would need to add E/15/A relays for fire and fault Please see scimitar panel for full function panel – See page 65.

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

Batteries B/12V/3.2AH/SLA

(12 Volt 3.2Ah sealed lead acid battery (1 block)


EN54

18 MONTHS

Detectors Apollo protocol Series 65 – see page 65

Sounders & visual indicators

4 Wire Conventional Systems

Scimitar

195

All compatible sounders and isual indicators are listed below. Plus pages 66

Call points

Please note batteries are not included: all panels require 2 x B/12V/3.2AH/SLA to operate, listed below • • • • • • • • • • • • • •

LPCB certified to the latest versions of EN54 Parts 2 and 4 Intuitive user-friendly interface with colour coded buttons and combined keypad / keyswitch entry to access level 2 2, 4 or 8 zone circuits (dependent on model purchased) Four conventional sounder circuits Integral 1.5A EN54-4/A2 compliant switch mode PSU Two on-board relays (Fire and Fault) Two open-collector outputs (Remote and Reset) ‘Class change’ and alert inputs Installer-friendly design accommodates easy first fix and straightforward maintenance Attractive flush or surface mountable plastic lid and enclosure – no bezel required Low 25mA quiescent current Multiple indicators End of line units included (one per zone) Ancillary system expansion connections provided for up to eight two-wire repeaters (one F/CHSC/RDC network driver card required per system)

Product Code

Description

Panels F/CHSC/2

Scimitar 2-zone panel requires 2 x B/12V/3.2AH/SLA battery

F/CHSC/4

Scimitar 4-zone panel requires 2 x B/12V/3.2AH/SLA battery

F/CHSC/8

Scimitar 8-zone panel requires 2 x B/12V/3.2AH/SLA battery

Batteries B/12V/3.2AH/SLA

12 Volt 3.2Ah sealed lead acid battery (1 block)

Apollo series 65 detectors

The most common call points are listed below – please see page 93 for break glass cover units. Specification Construction

Plastic lid and base

Enclosure Finish

RAL7035

Panel Dimensions

IP30

Panel Dimensions

380mm (W) x 235mm(H) x 96mm(D) 2, 4 & 8 panels have the same measurements

Weight

1.75 Kg (without batteries)

Enclosure Finish

RAL7035 Textured

Panel Dimensions

380mm (W) x 235mm(H) x 96mm(D) 2, 4 & 8 panels have the same measurements

Weight

1.75 Kg (without batteries)

Product Code

Description

Sounders & visual indicators F/CHWB/BN/RD/DB

LED sounder beacon deep base

F/CHBN/RD/DB

24V Red LED beacon – deep base

F/CHBL/6/2

17-27V 6” Red fire bell

F/CHWB/R

High output electronic sounder – white square

F/CHWB/RD/DB

Electronic warbler/siren red – deep base

F/CHSM/P

(55000-317) Optical smoke detector + base

F/CHWB/D

Base sounder White

F/CHSM/P/65

(Smoke head only without base)

F/CHBN/D/RING

Beacon to fit over F/CHWB/D

F/CHHF/A

(55000-122) Fixed temp (57oC) H D + base. Individually boxed and labelled Type A1Rp

F/CHWB/D/COVER/WH

White cover to fit F/CHWB/D

F/CHHF/A/HT

(55000-137) High temp (90oC) H D + base Type CS

F/CHBG/S/5

Break glass – surface

F/CHBG/WP/5

Waterproof break glass

F/CHHR/A/65

(55000-127) Rate of rise heat detector Type BR

S/CP/COVER

Call Point Cover

S/CP/KEY

Call Point Key

F/CHHR/A/HT/65

High temperature heat detector. Rate-of-Rise (100’c) Type CR

F/CHRI/60

Remote indicator

Call points

Repeater Panel F/CHSC/R

8 zone repeater panel

F/CHSC/RDC

Repeater driver card

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

195


Conventional Visual Alarm Device (VADs)

3-YEAR GUARANTEE

Ceiling Mounted

F/VAD/C/1

F/VAD/WB/C/2

F/VAD/C/3

F/VAD/WB/C/4

Product Code

Description

F/VAD/C/1

Ceiling Mounted Visual alarm device White body Red flash. Shallow base. 25mA in alarm 7m @3m mounting height

F/VAD/WB/C/2

Ceiling Mounted Visual alarm device White body Red flash with 98dB sounder deep base. 40mA in larm 7m coverage @3m mounting height

F/VAD/C/3

Ceiling Mounted Visual alarm device Red body Red flash. Shallow base. 25mA in alarm 7m coverage @3m mounting height

F/VAD/WB/C/4

Ceiling Mounted Visual alarm device Red body Red flash with 98dB sounder. Deep base 40mA in alarm 7m coverage @3m mounting height

Wall Mounted

F/VAD/W/1

196

F/VAD/WB/W/2

F/VAD/W/3

Product Code

Description

F/VAD/W/1

Wall Mounted Visual alarm device White body Red flash. Shallow base 25mA in alarm 7m coverage @3m mounting height

F/VAD/WB/W/2

Wall Mounted Visual alarm device White body Red flash with 98dB sounder deep base. 40mA in alarm 7m coverage @3m mounting height

F/VAD/W/3

Wall Mounted Visual alarm device Red body Red flash. Shallow base 25mA in alarm 7m coverage @3m mounting height

F/VAD/WB/W/4

Wall Mounted Visual alarm device Red body Red flash with 98dB sounder. Deep base 40mA in alarm 7m coverage @3m mounting height

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

F/VAD/WB/W/4


EN54

2-YEAR GUARANTEE

4 Wire Conventional Systems

Kentec Sigma CP Conventional Range

197

• • • • • • • • • • • • • •

Fully certified to BS EN54-2 and BS EN54-4 2-wire and standard versions in 2, 4 or 8 zones Compatible for use on BS5839: Part 1: 2002 installations 2-wire repeaters and ancillary boards Fully programmable using simple menu options Adjustable sounder delay time Sounder configuration options Zonal sounder delay detectors only Zonal sounder delay call points only Coincidence input selection I.S Barrier selection by zone Short circuit fire by zone Non latching zones Silent zones Zone input delay

• • • • • • • • • • •

General panel configuration Simple, single board construction Installer friendly Compatible with wide range of detection devices Two monitored sounder outputs 3 Amp power supply Auxiliary power output Also available is a range of Ancillary Cards compatible with all Sigma CP Models. Up to 7 Cards of each model can be fitted To each Sigma CP Control Panel & Sigma CPR Repeater Panel Ranges. These include: Sigma Ancillary Board (K580) operating software version V2.0 or above. See DS39 for more details. Sigma Sounder Board (K461) operating software version V3.0

Product Code

Description

Product Code

F/KL11020M2

Sigma CP Conventional Panel 2 Zones: Surface + LCMU – Conventional

Repeaters

F/KL11040M2

Sigma CP Conventional Panel 4 Zones: Surface + LCMU – Conventional

F/E01020L2

Sigma CP-R Conventional Repeater Panel, 24V low profile enclosure, 2 Zones: Surface

F/KL11080M2

Sigma CP Conventional Panel 8 Zones: Surface + LCMU – Conventional

F/E01040L2

F/KA11020M2

Sigma CPA Alarmsense Conventional Panel, 2 Zones: Surface – 2 Wire

Sigma CP-R Conventional Repeater Panel, 24V low profile enclosure, 4 Zones: Surface

F/E01080L2

F/KA11040M2

Sigma CPA Alarmsense Conventional Panel, 4 Zones: Surface – 2 Wire

Sigma CP-R Conventional Repeater Panel, 24V low profile enclosure, 8 Zones: Surface

F/K01020M2

F/KA11080M2

Sigma CPA Alarmsense Conventional Panel, 8 Zones: Surface – 2 Wire

Sigma CP-R Conventional Repeater Panel with PSU 230V standard enclosure, 2 Zone: Surface

F/K01040M2

B/12V/7AH/SLA

12 Volt 7Ah Sealed Lead acid battery (1 block) 2 required per panel

Sigma CP-R Conventional Repeater Panel with PSU 230V standard enclosure, 4 Zone: Surface

F/K01080M2

Sigma CP-R Conventional Repeater Panel withPSU 230V standard enclosure, 8 Zone: Surface

t: 0845 884 7000

Description

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

197


2 Wire Conventional AlarmSense Channel has a range of Alarmsense fire alarm control panels, that offer a flexible cost-effective solution for conventional fire alarm systems. Both the detection & sounder devices are wired on the same 2 wire circuits to simplify installation. The Alarmsense range comes in 2 zone, 4 zone & 8 zone options, all have 4 conventional sounder circuits, giving further flexibility.

198

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

199


AlarmSense - 2 Wire

EN54

• • • • • • • • • • • • Please Note: Batteries are not included: All panels require 2 x B/12V/3.2AH/SLA – listed below

• • •

Product Code

Description

Description

AlarmSense

F/BASE/AS

(45681-244) Base for use with AlarmSense detectors

F/CHAS/2

AlarmSense 2-zone fire panel requires 2x B/12V/3.2AH/SLA batteries

F/CHHF/A/HT/AS

(55000-193) AlarmSense fixed high temperature heat detector Requires Base

F/CHAS/4

AlarmSense 4-zone fire panel requires 2x B/12V/3.2AH/SLA batteries

SP/CHSM/P/AS

(55000-390) AlarmSense optical detector Requires Base

F/CHAS/8

AlarmSense 8-zone fire panel requires 2x B/12V/3.2AH/SLA batteries

F/CHHF/AS

(55000-190) AlarmSense 55˚ rate of rise heat detector Requires Base

Apollo combination detectors, sounders & beacons F/CHHF/HT/AS/WB

(55000-197) AlarmSense high temp heat detector and sounder base type CS

F/CHHR/AS/WB

(55000-196) AlarmSense heat detector with sounder base A1R type

F/CHHR/AS/WB/ BN

(55000-198) AlarmSense heat detector with sounder base and beacon A1R type

F/CHSM/P/AS/WB

(55000-392) AlarmSense optical detector complete sounder base

F/CHSM/P/AS/ WB/BN

(55000-394) AlarmSense optical detector with sounder beacon base

Apollo sounders & visual indicators (45681-510) AlarmSense base sounder

F/CHWB/BN/AS

(45681-509) AlarmSense base mounted electronic sounder/beacon

F/CHWB/BN/RD/ AS

(55000-017) AlarmSense open-area red sounder beacon

F/CHWB/RD/AS

(55000-018) AlarmSense open area red sounder

F/CHRM/AS

(55000-835) AlarmSense relay module

F/CHWB/AS/CAP/ WH

(45681-294) White locking cap for AlarmSense base

SP/CHIF/AS

Input interface

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

Repeater panel F/CHSC/R

AlarmSense 8 zone repeater panel. Requires 2 x B/12V/3.2AH/SLA batteries

F/CHSC/RDC

Repeater driver card

S/E20/A

Relay card for use with AlarmSense (fitted in panel)

Batteries B/12V/3.2AH/SLA

12 Volt 3.2Ah sealed lead acid battery (1 block)

Remote indicator F/CHRI/AS

AlarmSense remote indicator (Not for use with sounder base units)

Call points

F/CHWB/D/AS

Accessories

200

GUARANTEE

A powerful C-TEC manufactured, LPCB approved EN54 compliant 2-wire fire alarm panel Designed to work with Apollo’s AlarmSense range of detectors, call points, sounders and beacons Available with 2, 4 and 8 AlarmSense zone circuits Installer-friendly design accommodates easy first fix and straightforward maintenance Attractive flush or surface mountable plastic lid and enclosure Auxiliary remote, fire, fault and reset outputs ‘Class change’ and alert inputs Four conventional sounder circuits (for use with non- AlarmSense sounders) Low quiescent current – for extended standby times with small batteries Intuitive user-friendly interface Multiple indicators provide a comprehensive overview of system status System expansion connections for up to eight two-wire repeater panels and a range of Relay Output Cards Wide range of engineering functions including zone test coincidence, zone delay and non-latching zones Two on-board relays (Fire and Fault) Two open-collector outputs (Remote and Reset)

Product Code

Apollo detectors & base

2-YEAR

F/CHBG/S/AS/2

(55400-894) AlarmSense surface break glass

F/CHBG/AS/COVER

Call Point Cover

S/BG/TESTKEY/AS

Call Point Key

Specification Construction

Polycarbonate enclosure

Enclosure Finish

RAL7035

Panel Dimensions

380mm(W) x 235mm(H) x 96mm(D) 2, 4 & 8 panels have the same measurements

Weight

1.75 Kg (without batteries)

w: deta.co.uk


2-YEAR GUARANTEE

Two-wire AlarmSense has been developed to make the design and installation of a fire detection and alarm system easier and more economic for small to medium sized buildings. The range also allows an existing system to be extended or modified if necessary, this flexibility makes AlarmSense an excellent choice for use in Houses of Multiple Occupation (HMO’s). Most conventional fire systems are designed to work with two pairs of wires per zone: one pair for detection devices such as smoke detectors, heat detectors and manual call points; the other for alarm devices such as bells, sounders or strobes. By using different voltage bands for quiescent and alarm states, AlarmSense components can be connected to the same pair of supply wires.

2 Wire Conventional Systems

AlarmSense - 2 Wire Compatible Devices

201

When powered and controlled by the AlarmSense two-wire fire panel, this reliable technology takes all the complexity out of fire alarm system design, leading to quicker, less expensive and more flexible installations. Research shows an AlarmSense twowire system can achieve up to 40% reduction of labour over a standard four wire conventional system.

Combined Detectors

Detectors

SP/CHSM/P/AS Optical smoke detector

F/CHWB/D/AS & F/CHWB/ AS/CAP/WH Base sounder with white locking cap

F/CHHF/HT/AS/WB Combined Heat detector w/ sounder base

F/CHHF/A/HT/AS Heat detector

F/CHWB/BN/RD/AS Red sounder visual indicator

F/CHWB/RD/AS Red sounder

F/CHSM/P/AS/WB Optical smoke detector w/ sounder base

F/CHBG/S/AS/2 Surface mounted break glass

Call Points

Sound And Visual Indicators

Typical System Architecture - AlarmSense Zone 1

AlarmSense Panel

Detector

Zone 2

Detector with Sounder Base

Detector with Sounder Beacon Base

Manual Call Point Base

End of line Device

Please note: Do not use Series 65 detectors on AlarmSense Systems, they could cause severe system malfunction. Please note: Batteries may vary due to stand-by times and number of devices on your system. If in doubt please contact our technical team on 0845 884 7000 or email technical@channelsafety.co.uk

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

201


Sabre Pro - 2 Wire

EN54

2-YEAR GUARANTEE

Please Note: Batteries are not included, all panels require 2x B/12V/3.2AH/SLA to operate, listed below.

Specification • • • • • • • • • • • • • • • •

Complies to BS5839 and EN54 part 4 32 devices per zone Output module available for plant shutdown or door release Panels are supplied without battery – options are listed 4 line x 20 character LCD display Ability to differentiate between callpoint or detector alarms Checkpoint alarm verification procedure Highlighted selection menu Event log storing up to 500 events 3 enhanced test modes Allows detectors & sounders to be installed on the same pair of wires Built-in EOL capability in all devices Use of Multipoint detector offers 7 modes of detection No extra devices needed for audible warning Self-calibrates every 6 hours Continuously monitors for dust contamination

Product Code

Description

Kits F/CHSA/2/PRO/KIT

Sabre Pro 2 zone fire alarm kit c/w 2 call points, 6 optical smoke/heat sounders & 1 head removal tool

F/CHSA/4/PRO/KIT

Sabre Pro 4 zone fire alarm kit c/w 2 call points, 6 optical smoke/heat sounders & 1 head removal tool

F/CHSA/8/PRO/KIT

Sabre Pro 8 zone fire alarm kit c/w 2 call points, 6 optical smoke/heat sounders & 1 head removal tool

5VB rated ABS

Battery Charger

170 mA current limiter

Battery (reverse polarity)

3.2AH F 20mm (in line with battery leads) Glass

Panel Dimensions

Fascia 331mm2 – Back box 305mm – Depth 99mm

Weight (excluding batteries)

2 Zone – 2.25 Kg 4 Zone – 2.28 Kg 8 Zone – 2.36 Kg

Product Code

Description

Detectors F/CHBN/SU/SA

Saber sounder/strobe wired on zone 90dBA

F/CHSU/I/SA

Saber industrial horn sounder 90dBA

F/CHSA/SH/PRO

Saber combined optical smoke/heat detector

F/CHSA/SHS/PRO

Saber combined optical somke/heat detector and sounder 90dBA

F/CHSA/SHSB/PRO

Sabre combined optical smoke/heat detector and sounder/beacon 90dBA

Sounders & Visual Indicators F/CHSU/SA

Sabre red electronic sounder unit

Call Points

Panels

F/CHBG/S/SA/CV

F/CHSA/2/PRO

Sabre Pro 2 zone dual wire fire alarm panel (requires 2 x B/12V/3.2AH/SLA batteries)

Sabre series break glass call point complete with cover

F/CHBG/S/SA/WP

Sabre series IP65 break glass call point

F/CHSA/4/PRO

Sabre Pro 4 zone dual wire fire alarm panel (requires 2 x B/12V/3.2AH/SLA batteries)

S/BG/COVER/SA

Call Point Cover

S/BG/TESTKEY/SA

Call Point Key

Sabre Pro 8 zone dual wire fire alarm panel (requires 2 x B/12V/3.2AH/SLA batteries)

Input / Output Modules

F/CHSA/8/PRO

F/CHSA/PRO2/R

Sabre Pro repeater panel for 4 and 8 Zone Panels Only

Remote indicator F/CHRI/60

Remote indicator

Batteries B/12V/3.2AH/SLA

202

Construction

t: 0845 884 7000

12 Volt 3.2Ah sealed lead acid battery – 2 required

|

e: sales.lfs@deta.co.uk

|

F/CHSW1/SA

Sabre Input / Output module

Other Accessories F/CHHRT/SA/PRO

Sabre head removal tool

F/CHSA/4CONV

Expansion card for 4 zone panel to add 4 conventional zones (4 zone panel only)

F/CHSA/4/PRO/ CARD

4 Zone expansion PCB to add 4 x two wire zones (4 zone panel only)

w: deta.co.uk


2-YEAR GUARANTEE

2 Wire Conventional Systems

Sabre Pro - 2 Wire Compatible Devices

203

F/CHSA/SH/PRO, F/ CHSA/SHS/PRO & F/CHSA/SHSB/PRO

F/CHBN/SU/SA Sounder / Strobe wired on zone

F/CHSU/I/SA Industrial Horn Sounder

F/CHSU/SA Electronic Sounder Unit

F/CHBG/S/SA/CV Break Glass Call Point

Please note: Only Sabre Pro detectors, combination detectors/sounders, call points and sounders & visual indicator devices should be used with Sabre Pro panels.

Cut False Alarm Costs • • • •

Drift-compensation reduces false alarms, but this feature is not normally found in conventional or two wire systems The Sabre detector not only has this feature as standard, but when it reaches its upper limit there is a warning on the panel and at the detector The Sabre Pro system also has an in built pre alarm facility that can be programmed through the control panel. This “Alarm Confirmation” feature can significantly reduce the effect of nuisance alarms

A single repeater panel can be powered using 24v from the main panel. More than one repeater panel requires a seperate PSU.

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

203


Analogue Addressable Channel offers several panels with Firewatch, Kentec and Advanced are available. All panels offered by Channel work with either Apollo or Hochiki protocol. Channel stock a wide range of apollo XP95 devices and Hochiki ESP to support any analogue addressable design requirement.

204

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

205


Firewatch Panels - FW1001 • •

• • • • Please Note: Batteries are not included: Batteries are not included, 16 Zone panels require 2x B/12V/2.8AH/SLA to operate, 32 Zone panels require 2x B/12V/7AH/SLA to operate.

• • • • •

Compatible with Apollo’s XP95/ Discovery and Hochiki’s ESP protocols The ability to interconnect up to eight Firewatch main panels (any variant) onto a two wire RS485 network. Alternatively, up to eight Firewatch repeaters can be connected to a nonnetworked Firewatch main panel Combined keypad/keyswitch entry to access levels 2 & 3 Two independently programmable conventional sounder circuits Two programmable inputs A fault output relay and three programmable relay outputs with voltage free changeover contacts Three zone dependency functions (A, B & C to EN54-2 clause 7.12) A day/night (building occupied/ unoccupied) function An investigation delay period function A phased evacuation and delays to outputs facility to EN54-2 An alarm counter that records the

EN54

• • • • • • • •

3-YEAR GUARANTEE

number of times the panel has been in an alarm state to EN54-2 Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop An integral EN54-4/A2 switch mode PSU rated @ 185-260V a.c 50-60Hz (1.4A on a 16 zone panel, 3A on a 32 zone panel) Earth fault monitoring An easy to read, 80 character backlit display 40 characters of custom text per device 999 event monitoring Comprehensive test facilities to EN54-2 and a wide range of functions including auto-learn loops, monitor a point, test outputs, one man walk test and loop continuity test An intuitive Windows based uploaddownload PC program that allows the system to be programmed quickly and easily

Specification Internal Power Supply

27V DC Nominal

Earth Fault Monitoring

Yes (any conductor)

Max. No. of Addressable devices per loop

126

Max. No. of Loop powered sounders per loop @ 10mA

40

Weight (excluding batteries)

Single loop 16 zone 1.8Kg Two loop 32 zone panel – 4.5Kg

Product Code

Description

Kits F/FW1001/1/16

Networkable single loop 16 zone panel (requires 2 x B/12V/3.2AH/SLA batteries)

F/FW1001/2/32

Networkable two loop 32 zone panel (requires 2 x B/12V/7AH/SLA batteries)

F/FW1001/R/16

Networkable repeater panel – 16 zones (requires 2 x B/12V/3.2AH/SLA batteries)

F/FW1001/R/32

Networkable repeater panel – 32 zones (2 x B/12V/7AH/SLA batteries)

F/FW1001/NCC/32

Network communications card for 32 zone for main panel

F/FW1001/NCC/16

Network communications card for 16 zone for main panel

Panel Batteries B/12V/3.2AH/SLA

12 Volt 3.2Ah sealed lead acid battery (1 block)

B/12V/7AH/SLA

12 Volt 7Ah sealed lead acid battery (1 block)

Hush Buttons F/FW1001/HB

BS5839-6 Hush button, Apollo XP95 / Discovery

Which Protocol? Firewatch FW1001 Panels are compatible with Apollo XP95/Discovery and Hochiki/ESP devices – please see pages 78-83 (Hochiki panel needs to be ordered if using Hochiki devices) Please note: Batteries are not included • Please state when ordering whether you require Apollo or Hochiki protocol • Batteries may vary due to stand-by times and number of devices on your system. If in doubt please contact our technical team on 0845 884 7000 or email technical@channelsafety.co.uk

206

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


• • • • • • • • • •

16 zonal LED indicators 2 programmable sounder circuits 5 programmable inputs 3 programmable relays 3A power supply Large graphic display Real time clock Expandable from 1 to 2 loops* Certified to EN54-2/ EN54-4 Up to 512 additional programmable I/O via Syncro I/O modules* Powerful, network wide cause and effects* Sensitivity adjustment and Drift Compensation Can be networked with Syncro control panels* Compatible with Focus and View repeaters* Supports Apollo and Hochiki protocols (see pages 79-83 & 83) Same look and feel as Syncro range

• • • Please Note: Batteries are not included, 16 Zone panels require 2x B/12V/2.8AH/ SLA to operate, 32 Zone panels require 2x B/12V/7AH/SLA to operate.

EN54

• • •

• • • • • •

• • • • • • •

2-YEAR GUARANTEE

Stores 500 last events in event log Dial up modem connection available Compact, stylish enclosure Installer friendly, removable equipment chassis Different language and character set variants available Fully EN54-2 and EN54-4 compliant improved front loading Printer option, only available in an M3 size enclosure. Also backward-compatible with Series 90 detectors Comprehensive day/night mode facility Programmable one touch test mode Powerful and versatile cause & effect programming Cause & effect wizard including: Cause & effect action Disablement configuration Test mode configuration

Analogue Addressable Systems

Kentec Syncro AS Addressable Range

207

*These items not available on Syncro AS Lite panel

Product Code

Description

“Syncro AS Lite” - Single Loop Standalone Analogue Addressable Fire Control Panel F/LA81161M2

Syncro AS Lite Analogue Addressable Control Panel 1 loop: Apollo Protocol, Surface

F/LA80161M2

Syncro AS Lite Analogue Addressable Control Panel 1 loop: Apollo Protocol, Surface, c/w Enable Key Switch

F/LH81161M2

Syncro AS Lite Analogue Addressable Control Panel 1 loop: Hochiki Protocol, Surface

F/LH80161M2

Syncro AS Lite Analogue Addressable Control Panel 1 loop: Hochiki Protocol, Surface, c/w Enable Key Switch

“Syncro AS “ – Single Loop Analogue Addressable Fire Control Panel – Expandable to 2 loops F/A81161M2

Syncro AS Analogue Addressable Control Panel 1 lop: Apollo Protocol, Surface

F/A80161M2

Syncro AS Analogue Addressable Control Panel 1 loop: Apollo Protocol, Surface, c/w Enable Key Switch

F/H81161M2

Syncro AS Analogue Addressable Control Panel 1 loop: Hochiki Protocol, Surface

F/H80161M2

Syncro AS Analogue Addressable Control Panel 1 loop: Hochiki Protocol, Surface, c/w Enable Key Switch

Extras & Spares S/K586A

Syncro AS Loop 2 Extension Card: Apollo Protocol

S/K586H

Syncro AS Loop 2 Extension Card: Hochiki Protocol

S/K555

Syncro Fault Tolerant Network Interface Card

S/X187LS

Software Download Lead (Compatible with all Panels): Economy

S/K18002

Vision Window cover assembly (M2 size)

S/K14060

LCMU Line Coninuity Monitoring Unit

S/M2FCLGT

Bezel for Semi Flushing Panel to Wall – M2

S/K768P2

Printer Module in enclosure(385w x 125h x 90D Cabinet)

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

207


We are proud to work closely with Advanced Fire Systems and can offer all their product range. We have highlighted a few of the more popular systems, please contact us if you need further information. TouchControl

Product Code

Description

TOUCH-10

Touch-screen terminal (standard network)

TOUCH-10/FT

Touch-screen terminal (fault-tolerant network)

TOUCH-10-SBB

Touch-screen terminal – Surface Back Box

TouchControl – Touchscreen remote control terminal with active maps TouchControl is the sleek and versatile remote control terminal and repeater from Advanced. Combining aesthetics with practicality, the lowprofile, high-resolution touchscreen makes it easy to check fire system status via interactive maps and zone plans, while complementing even the most stylish interiors. When in standby, you can use TouchControl to display company branding, advertisements and information – it will instantly revert to fire operation when a fire condition occurs. Simple to install, configure and operate, TouchControl delivers the highest levels of performance, quality and ease of use so you can enjoy complete peace of mind.

ExGo – High-performance gas extinguishing panels Quality and reliability are vital in protecting critical infrastructure, whether this be oil pipelines and tunnels or sensitive and historically important assets, such as datacentres, priceless documents or works of art. ExGo gas extinguishing panels from Advanced are relied upon around the world to protect sensitive and strategic assets – and the people who use them – from fire. When none other than the highest performing gas suppressant panel will do, Advanced delivers a simple, dependable solution to complex problems in high-risk sites.

LifeLine – Robust Alarm and Emergency Communication Notification In a fire situation, seconds matter. Clear and instant transmission of fire alarm alerts, live notification of system status and pre-programmed messages all need communicating clearly. Advanced’s LifeLine solution transmits specific emergency communications via personal pagers to site staff, engineers and the hearing impaired. Trusted across a wide range of sites – from healthcare and education settings to sprawling manufacturing plants and prestigious high-rise developments – LifeLine is easy to configure, install and operate.

208

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Analogue Addressable Systems 209

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

209


MxPro 5 Advanced Fire Alarm Control Panels

• • • • • • • • • • • • • • • • • • • • • • • • • • •

London’s Natural History Museum is protected using an Advanced MXPro system

210

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

EN54

3-YEAR GUARANTEE

1, 2, 4 or 8 loop formats Up to 254 devices per loop (protocol dependent) Up to 200,000 devices per network Networkable up to 200 nodes Built in voltage and current meters On board or optional remote battery temperature sensor Advanced’s simple select and click programming and configuration Quick start and protect – A working system after an Auto learn is performed 20 built-in, fully programmable LEDs 5000 event log entries 201 programmable false alarm management areas per panel Timed enablement of isolated zones, input and output devices Backward compatibility with MxPro 4 network Approved to EN54 Parts 2, 4 and 13 Certified by FM Approvals to EN54 Parts 2 and 4 Autolearn and loop detection Up to 2000 fire detection zones True peer-to-peer networking Supports intelligent/programmable remote terminals, BMS interface, IP Gateway and I/O Drivers Circuit monitoring from any panel or repeater Direct USB and RS232 PC connections Peripheral expansion built in 4 programmable push buttons Complete device history from each panel Programmable screen logo Advanced logic delivering huge configuration opportunities Compatible with Apollo, Argus, Hochiki and Nittan protocols


Analogue Addressable Systems 211

MxPro 5 Panels (Apollo/Hochiki Protocol) Product Code

Description

F/CH/MX-5101

1-Loop Fire Panel in Small enc. (Comes with 20 zone LED indicators)

F/CH/MX-5201

1-2 Loop Fire Panel c/w 1 Loop card in Medium enc. (Comes with 20 zone LED indicators)

F/CH/MX-5202

1-2 Loop Fire Panel c/w 2 loop cards in Medium enc. (Comes with 20 zone LED indicators)

F/CH/MX-5401

1-4 Loop Fire Panel c/w 1 Loop card in Large enc. (Comes with 20 zone LED indicators)

F/CH/MX-5402

1-4 Loop Fire Panel c/w 2 Loop cards in Large enc. (Comes with 20 zone LED indicators)

F/CH/MX-5403

1-4 Loop Fire Panel c/w 3 Loop cards in Large enc. (Comes with 20 zone LED indicators)

F/CH/MX-5404

1-4 Loop Fire Panel c/w 4 Loop card in Large enc. (Comes with 20 zone LED indicators)

F/CH/MX-5802

2-8 Loop Fire Panel c/w 2 Loop cards. Standard network (Comes with 20 zone LED indicators)

F/CH/MX-5803

2-8 Loop Fire Panel c/w 3 Loop cards. Standard network (Comes with 20 zone LED indicators)

F/CH/MX-5804

2-8 Loop Fire Panel c/w 4 Loop cards. Standard network (Comes with 20 zone LED indicators)

F/CH/MX-5805

2-8 Loop Fire Panel c/w 5 Loop cards. Standard network (Comes with 20 zone LED indicators)

F/CH/MX-5806

2-8 Loop Fire Panel c/w 6 Loop cards. Standard network (Comes with 20 zone LED indicators)

F/CH/MX-5807

2-8 Loop Fire Panel c/w 7 Loop cards. Standard network (Comes with 20 zone LED indicators)

F/CH/MX-5808

2-8 Loop Fire Panel c/w 8 Loop cards. Standard network (Comes with 20 zone LED indicators)

F/CH/MX-5802/FT

2-8 Loop Fire Panel c/w 2 Loop cards. Fault-tolerant network (Comes with 20 zone LED indicators)

F/CH/MX-5803/FT

2-8 Loop Fire Panel c/w 3 Loop cards. Fault-tolerant network (Comes with 20 zone LED indicators)

F/CH/MX-5804/FT

2-8 Loop Fire Panel c/w 4 Loop cards. Fault-tolerant network (Comes with 20 zone LED indicators)

F/CH/MX-5805/FT

2-8 Loop Fire Panel c/w 5 Loop cards. Fault-tolerant network (Comes with 20 zone LED indicators)

F/CH/MX-5806/FT

2-8 Loop Fire Panel c/w 6 Loop cards. Fault-tolerant network (Comes with 20 zone LED indicators)

F/CH/MX-5807/FT

2-8 Loop Fire Panel c/w 7 Loop cards. Fault-tolerant network (Comes with 20 zone LED indicators)

F/CH/MX-5808/FT

2-8 Loop Fire Panel c/w 8 Loop cards. Fault-tolerant network (Comes with 20 zone LED indicators)

Larger zone cards available – please contact channel

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

211


Apollo XP95 Protocol • • • •

Digital Protocol for error free transmission Alarm Flag for fast alarm reporting Alarm Address for fast location of alarm Automatic addressing with the patented XPERT card

• • • • •

EN54

Electronics-free, easy fit base Ease of installation Wide range of compatible interface units Wide range of compatible panels Compatible with Series 90 and Discovery

Call Points

GUARANTEE

Elegant, unobtrusive design Wide range of products Great flexibility in system design

Detectors

F/CHBG/IS/95/2

F/CHBG/ WP/95/1

Back Row, left to right: F/CHSM/P/95, F/CHHM/95 & F/CHHM/HT/95 Front Row, left to right: F/CHSM/A/95, F/CHSM/M/95 & F/BASE/95

Product Code

Description

Product Code

Description

S/BG/TESTKEY/AS

Call Point Test Key

F/CHHM/95

(55000-400) Temperature monitor less base

F/CHBG/IS/95/2

(TP SA5900-908) Analogue addressable break glass – complete with isolator and flexible element

F/CHHM/HT/95

(55000-401) High temperature H D less base

F/CHSM/M/95

(55000-885) Multi-sensor detector

F/CHBG/AS/COVER

Call Point Cover

F/CHSM/P/95

(55000-600) Optical smoke monitor less base

(58200-950) XP95 weatherproof break glass

F/BASE/95

(45681-210) Mounting base – series XP95

F/CHBG/WP/95/1

Sound & Visual Indicators

F/CHWB/95/ AP

212

• • •

10-YEAR

F/CHWB/ BN/95/AP

F/CHBN/95

Interfaces & Isolators

F/CHIO/ 1/95/240

F/CHBN/ BASE/95

F/CHIO/ 2/95

F/CHIS/ 95/DB

Product Code

Description

Product Code

Description

F/CHBN/95

(55000-877) XP95 loop powered beacon – requires F/BASE/95

F/CHIO/1/95

F/CHBN/BASE/95

(45681-333) Beacon with detector base

(SA4700-102) Single channel input/ output unit complete with isolator. Contacts rated 30V 1Amp

F/CHWB/95/AP

(55000-001) Open area XP95 sounder red IP65 complete with isolator

F/CHIO/1/95/240

(SA4700-103) Single channel input/ output unit 230V contacts 1A complete with surface mounting enclosure

F/CHWB/BN/95/A

(45681-331) Loop powered base sounder beacon – incorporates detector mounting base

F/CHIO/2/95

(SA4700-104) Twin channel input/ output unit complete with isolator

F/CHWB/BN/95/AP

(55000-005) Open area XP95 sounder beacon red IP65

F/BASE/95/IS/WB

F/CHWB/BN/95/IS

(45681-330) Loop powered base sounder beacon – complete with loop isolator and detector mounting base

(45681-331) Loop powered base sounder beacon – incorporates detector mounting base

F/CHWB/IS/IN/95A

(45681-277) Loop powered intelligent base sounder – incorporates detector mounting base

F/COVER/RD/1

(45681-293) Red cover for CHWB/BN/95/A

F/COVER/WH/1

(45681-292) White cover for CHWB/ BN/95/A

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

F/CHIS/95/DB

(55000-720) XP95 isolator less base

F/CHSN/95

(45681-284) Short circuit isolator with detector base

F/CHSW/95

(55000-852) Sounder circuit controller complete with isolator

F/CHZM/IS/95

(SA4700-100) Switch monitor complete with isolator

F/COVER/WH/1

55000-845 Zone monitor

w: deta.co.uk


10-YEAR GUARANTEE

There are 3 categories of VADs: C - Ceiling Mounted: When mounted on a ceiling a level of 0.4 lux is achieved over a known area

Analogue Addressable Systems

XP95 Visual Alarm Device (VADs)

213

W - Wall Mounted: When mounted on a wall a level of 0.4 lux is achieved over a known area F/55000-/42

O - Open Category: Manufacturers specify the area coverage of the VAD Ceiling Mounted

F/55000/744

Product Code

Description

F/55000/742

Ceiling Mounted 55000-742 XP95/ Discovery – Red body White flash. 9.4mA in alarm 8.5m coverage @3m mounting height

F/55000/745

Ceiling Mounted 55000-745 XP95/ Discovery – White body White flash. 9.4mA in alarm 8.5m coverage @3m mounting height

F/55000/740

Ceiling Mounted 55000-740 XP95/ Discovery – Red body White flash. 26.6mA in alarm 15m coverage @3m mounting height

F/55000/743

Ceiling Mounted 55000-743 XP95/ Discovery – White body White flash. 26.6mA in alarm 15m coverage @3m mounting height

Wall Mounted

F/45681/709

Product Code

Description

F/55000/741

Wall Mounted 55000-741 XP95/ Discovery – Red body White flash. 9.4mA in alarm 6m³ coverage @2.4m mounting height

F/55000/744

Wall Mounted 55000-744 XP95/ Discovery – White body Red flash. 9.4mA in alarm 6m³ coverage @2.4m mounting height

F/BF451A/CX/SRC

Wall Mounted Sounder/VAD W-3-3.1 VAD c/w 91dB(A) Sounder

Open Category Product Code

Description

F/45681/709

Open Category 45681-709 XP95/ Discovery BASE MOUNTED VAD White flash. 9.4mA in alarm. Approx coverage 3m Dia @ 3m mounting height

F/45681/705

Ceiling Mounted 45681-705 XP95/ Discovery BASE MOUNTED SOUNDER /VAD White flash. 14mA in alarm. Approx coverage 3m Dia @ 3m mounting height

F/BF451A/CX/SRC

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

213


Apollo XP95 Discovery

EN54

10-YEAR GUARANTEE

Compatible Products

F/CHBG/IS/DISC Break Glass complete with isolator

All Discovery smoke detectors include compensation for sensor drift caused, for example, by dust in the chamber, and will hold the sensitivity at a constant level even with severe chamber contamination.

Drift Compensation Access to the Discovery range of audio visual signalling equipment with advanced features such as choice of volume, tones, including class change.

Sensitivity Selection Each Discovery detector can operate in one of five response modes, which can be selected from the control panel. The response characteristics of the detectors have been carefully set so that the detectors will comply with the requirements of the relevant EN54 in all response modes. Mode selection depends on application – Mode 1 will give a higher sensitivity to fire than in Mode 5.

Left to right: F/CHWB/BN/DISC/AP/R (Open-Area Sounder Indicator – Red Lens), F/CHWB/BN/DISC/A (Sounder Visual Indicator Base)

• • • • • • • • •

Rejection of transient signals Flashing LED option Five response modes for ease of optimisation to changing environments Drift compensation to ensure constant sensitivity Four bytes of user programmable non-volatile memory Alarm flag for fast alarm reporting Conventional alarm facility during CIE processor fault 360° visibility in alarm Compatible with XP95 systems

Left to right: F/CHSM/P/DISC (Optical Detector less Base), F/CHHM/DISC (Heat Monitor less Base), F/ CHSM/A/DISC (Ionisation Detector less Base), F/ CHSM/M/DISC (Smoke/Heat Detector less Base)

Product Code

Description

Sounders And Visual Indicators F/CHSM/P/DISC

(58000-600) Discovery optical detector less base

F/CHHM/DISC

(58000-400) Discovery heat monitor less base

F/CHSM/A/DISC

(58000-500) Discovery ionisation detector less base

F/CHSM/M/DISC

(58000-700) Discovery smoke/heat detector less base

Apollo Sounders and Visual Indicators F/CHWB/BN/DISC/A

(45681-393) Discovery sounder visual indicator base

Please note: • We have portrayed the most commonly used Discovery devices here – yet for further options please contact our sales department on 0845 884 7000 or email customerservices@channelsafety.co.uk. • For interface units – XP95 interfaces on the previous page can be used. Contact our technical team at technical@channelsafety.co.uk to check compatibility prior to ordering.

214

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


10-YEAR GUARANTEE

Currently covering heat and optical detection areas – either individually or in innovative combinations – the exclusive technology incorporated into the Soteria range offers an unrivalled host of benefits, including: • • • • • • • •

Product Code

Enhanced reliability of smoke detection Reduction in false alarms PureLight® technology Simple installation with a new easy-fit base and an isolator located in the head. A sleek and stylish low profile design Compatible with XP95 & Discovery protocols Comprehensively tested to exceed EN54 standards Extensively tested at Apollo’s state of the art in-house testing facilities

Analogue Addressable Systems

Apollo Soteria

215

Description

Soteria Mid Level Detectors with Isolator F/SA5100-600APO

Soteria Optical Smoke Detector with Isolator

F/SA5100-400APO

Soteria Heat Detector with Isolator

F/SA5100-700APO

Soteria Optical/Heat Multisensor Detector without Isolator

Soteria Mid Level Detectors without Isolator F/SA5000-600APO

Soteria Optical Smoke Detector without Isolator

F/SA5000-400APO

Soteria Heat Detector without Isolator

F/SA5000-700APO

Soteria Optical/ Heat multisensor Detector without Isolator

F/SA5000-200APO

Xpert8 Intelligent Mounting Base

Dimension Optical Detector

FL5100-600APO Measurements 140mm Diameter x 71mm Depth (with Backbox)

Dimension Specialist Optical Detector FL6100-600APO Measurements 170mm Diameter x 71mm Depth (with Backbox)

Soteria Heat Detector Dimension Backbox

FL5000-200APO Measurements 113mm x 71mm Depth

SA5000-400 (Non Isolated) SA5100-400 (Isolated) Measurements 100mm x 38.5mm Height

Soteria Multisense Detector

SA5000-700 (Non Isolated) SA5100-700APO (Isolated) Measurements 100mm x 38.5mm Height

Optical Smoke Detector

SA5000-600 (Non Isolated) SA5100-600APO (Isolated) Measurements 100mm Diameter x 36mm Height

Xpert 8 Intelligent Mounting Base

SA5000-200 XPERT 8 Card 38532-064 Measurements 100mm x 12mm Depth

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

215


Apollo Soteria Dimension

• • • • • • • • • • •

10-YEAR GUARANTEE

Soteria Dimension Optical Detector

Soteria Dimension Specialist Optical Detector

Soteria Dimension Optical Detector

Soteria Dimension Mounting Box

Comprehensively tested to exceed EN 54–7 standard With the intelligence of CoreProtocol Backwards compatible with XP95 and Discovery systems Unique chamberless fire detection technology Intelligent sensing of foreign and transient objects to reduce false alarms Integrated Switchable Isolator as standard Virtual chamber eliminates dust and insect ingress External light rejection Drift compensation Tri-Coloured LED status indicator Custom finishes available

Product Code

Description

F/FL5100-600APO

Soteria Dimension Optical Detector

F/FL6100-600APO

Soteria Dimension Specialist Optical Detector

F/FL5000-200APO

Soteria Dimension Mounting Box

Please note: Supply and installation of Soteria Dimension detectors is subject to a satisfactory site survey

216

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


EN54

• • • • • •

2-YEAR GUARANTEE

Removable, high performance chamber Twin fire LEDs allow 360 viewing Locking mechanism (sensor to base) Variable sensitivity – Electronically addressed All base fixing centres are 48 – 74mm Approved by LPCB & VdS

Product Code

Analogue Addressable Devices

Hochiki ESP Protocol

217

Description

Detectors

F/CH/ATJ-EN(WHT) (Analogue heat sensor – white)

F/CH/ACC-EN (Multi-sensor – photoelectric & heat – ivory).

F/ALN-EN WHT

Photoelectric smoke sensor – White

F/ACC-EN WHT

Multi-sensor – photoelectric and heat – White

F/ATJ-EN WHT

Analogue heat sensor – White

Detector Bases For Above F/YBN/R/3 WHT

Sensor mounting base

F/YBN/R/3/SCI

Sensor mounting base with isolator

Base Sounders & Visual Indicators

F/CH/CHQ-WS2

F/CH/CHQ-WSB2

F/YBO-BS WHT

Addressable base mounted sounder white

F/YBO-BSB2WHTRL

Addressable white base mounted sounder/ indicator red led

F/SI/CAP2WHT

Base sounder cover white

Base Sounder Bases for Above F/YBO-R/3/WHT

Sounder mounting base white

F/YBO-R/SCIWHT

Sounder mounting base with circuit isolator white

Wall Sounders & Visual Indicators

F/CH/CHQ-WSB2/RL

F/CH/YBO-BS

F/CHQ-WS2

Wall sounder red

F/CHQ-WSB2/RL

Wall sounder indicator red LED red

F/CHQ-WPK

Weatherproof kit for CHQ above red

Wall Sounder Bases for Above F/YBO-R/3 RED

Mounting sounder base red

F/YBO-R/SCI RED

Short circuit isolator base red

CALL POINTS

F/CH/YBO-BSB2/RL

F/CH/CHQ-AB

F/HCP-E/SCI

Addressable call point with SCI red

F/HCP-W/SCI

Weatherproof addressable call point with SCI red

F/CH/PS200

Call point cover

Modules & Controllers F/CHQ-DSC2/SCI

Dual sounder controller with SCI

F/CHQ-DZM/SCI

Dual zone monitor with SCI

F/CHQ-MRC2/SCI

Mains relay controller with SCI

F/CHQ-SZM2/SCI

Single zone monitor with SCI

F/CHQ-SIM

Single input module

F/CHQ-POM

Powered output module

Accessories F/CHQ-ADAPTER

Adapter for new CHQ modules

F/SR/MOUNTING

Surface mounting box red

F/TCH-B200

ESP programmer & PL-3 lead

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

217


Wireless Addressable Analogue Devices Channel offer two excellent ranges for wireless fire detection. The Apollo Xpander system needs no special control panel and has proven self-monitoring technology. Installed at the Royal Albert Hall this system can have up to 32 devices per interface and up to 5 interfaces per loop. The Zerio Plus is perfect for large office block, hotels and restaurants with its sophisticated cause and effect and simple set-up.

218

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

219


Zerio Plus - Wireless

EN54

• • • • • • • • • • •

2-YEAR GUARANTEE

EN54 Compliant 240 Fully Addressable Devices Sophisticated Cause and Effects In-built HMO options Plugable Memory Module for Back-up USB Keyboard to program Intuitive Menu Structure Configuration Reporting via USB Memory Stick 5 Access Levels Compatible with full range of Zerio Plus Devices Simple to Set-up

Typical Applications • • • •

Large office blocks Hotels Small shops Restaurants

Display Panel Radio Booster Panel Control Panel Wired Transceiver Sensor Sounder Break Glass Unit

Please note: • A site survey required on all wireless equipment prior to installation • A free design service is offered upon receipt of contract awarded – for further details contact our sales office on 0845 884 7000.

220

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Detectors

2-YEAR GUARANTEE

Other Accesssories

Sounders & Call Point

Wireless Analogue Addressable Devices

EN54

221

Top to bottom: F/EDA-D6000, F/EDA-R6000, F/EDA-R5000, & F/EDA-D5000 Product Code

Top to bottom: F/EDA-A6000, F/EDA-A6030, F/EDA-C5000

Description

Top to bottom: F/EDA-T6080, F/EDA-T5100, F/EDA-Z6000 & F/EDA-Y5000

Product Code

Panels

Description

Interface Units

F/EDA-Z5008

8 zone Zerio Plus control panel (requires 1x 12/7 battery – listed below)

F/EDA-T6080

Zerio Plus radio clean contact input / output unit

F/EDA-Z5020

20 zone Zerio Plus control panel (requires 1x 12/7 battery – listed below)

F/EDA-A6040

Output only unit (Contacts rated at 30d DC 1A)

F/EDA-Z5100

100zone Zerio Plus control panel (Requires 1 x 12/7 battery – listed below)

F/EDA-A6041

Input/Output unit (Contacts rated at 30d DC 1A)

F/EDA-Z6011

Wireless interface for networked systems

Devices F/EDA-R5000

Zerio Plus optical smoke detector

F/EDA-R6000

Zerio Plus optical smoke detector complete with sounder

F/EDA-R6030

Zerio Plus optical smoke detector complete with sounder visual indicator

F/EDA-D6000 F/EDA-D5000

Boosters And Aerials F/EDA-Z6000

Zerio Plus booster panel (requires 240v Supply and 1 x 12/7 battery)

F/EDA-Z6010

Zerio Plus hard wired booster panel

Zerio Plus heat detector complete with sounder

F/EDA-Y5000

High gain antenna for use with Zerio Plus

Zerio Plus heat detector

Accessories

Call Point

F/EDA-Z5000

F/EDA-C5000

Zerio Plus call point

F/EDA-Q585

Call Point Cover

Zerio Plus survey kit

Batteries B/12V/7AH/SLA

12 Volt 7Ah sealed lead acid battery (1 block)

S/BATT/EDA-Q690

Replacement batteries for detectors

Sounders And Visual Indicators F/EDA-A6000

Zerio Plus radio sounder

F/EDA-A6060

Zerio Plus radio beacon

F/EDA-A6030

Zerio Plus Radio sounder c/w LED beacon

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

221


Apollo XPander • • • • • • • • • • • • • •

Easy to install XPERT card addressing Self-monitoring Proven technology No special control panel needed 868MHz radio channels Up to 32 devices per interface Up to 5 interfaces per loop Analogue addressable system expansion Wireless Eliminates cabling difficulties Minimises building disruption] Enables Rapid Retro-fit Preserves aethetics

All detectors within the XPander range are sold with mounting bases

Typical Applications XPander can be incorporated into fire detection systems where the use of fire cables is either impractical or undesirable, including stately homes and architecturally sensitive buildings.

Please note: • A site survey is required on all wireless equipment prior to installation • A free design service is offered upon receipt of contract awarded – for further details contact our sales office on 0845 884 7000.

222

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Detectors

10-YEAR GUARANTEE

Combined Sounders & Visual Indicators

Sounders & Call Point

Wireless Analogue Addressable Devices

EN54

223

F/CHSM/P/XPAND F/CHHM/XPAND Optical Smoke 60°C Heat Detector Detector

F/CHWB/BN/ XPAND Sounder Visual Indicator – 100db

F/CHWB/XPAND Sounder – 100db

F/CHSM/P/ WB/BN/XPAND Sounder-indicator (red) and optical detector

F/CHSM/P/WB/ XPAND Sounder and optical smoke detector

Installed in the Royal Albert Hall

F/CH/XPAND/SVU Survey Unit

Product Code

F/CHBG/XPAND Break Glass Unit

Description

Detectors F/CHSM/P/XPAND

(XPA-CB-12034) XPander wireless optical smoke detector

F/CHHM/XPAND

(XPA-CB-11170) XPander wireless (60oC) heat detector

Sounders & Visual Indicators F/CHWB/XPAND

(XPA-CB-14001) XPander wireless sounder – 100db (red)

Combined Detectors / Sounders F/CHSM/P/WB/XPAND

(XPA-CB-14016) XPander combined sounder and optical smoke detector

F/CHHM/WB/XPAND

(XPA-CB-14017) XPander combined sounder and heat detector (class A1R)

F/CHHM/HT/WB/XPAND

(XPA-CB-14018) XPander combined sounder and heat detector (class CS)

Combined Detectors / Sounders / Visual Indicators F/CHSM/P/WB/BN/XPAND

(XPA-CB-14020) XPander combined sounder-indicator (red) and optical detector

F/CHHM/WB/BN/XPAND

(XPA-CB-14021) XPander combined sounder-indicator (red) and heat detector (class A1R)

F/CHHM/HT/WB/BN/XPAND

(XPA-CB-14022) XPander combined sounder-indicator (red) and heat detector (class CS)

F/CHSM/P/WB/BNC/XPAND

(XPA-CB-14024) XPander combined sounder-indicator (clear) and optical smoke detector

Call Points F/CHBG/XPAND

(XPA-MC-14006) XPander wireless break glass unit

Interfaces And Aerials F/CHIF/XPAND

(XPA-IN-14050-APO) XPander interface module (loop powered) with isolator

Accessories S/XPERT TAG

(29600-399) XPander blank xpert card red

S/XPERT TAG/WH

(29600-413) XPander blank xpert card white

F/CH/XPAND/SVU

Survey Unit Kit

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

223


Vesda

VESDA-E VEA

VESDA-E VEU

VESDA-E VEP

Vesda - Accessories

Vesda-E Vea

The VESDA range of Pipes and Fittings have been specially developed to provide fully matched components for the optimal performance of your whole Vesda aspirating system. They are also manufactured to comply with the requirements of BS5391 Part 1, EN 61386-1 and the new EN54 Part 20 guaranteeing you quality.

The VESDA-E VEA series of detectors combine VESDA reliability and early warning smoke detection with pinpoint addressability and a variety of annunciation options that truly surpass traditional spot detectors. VEA uses patented sampling points and multi-channel microbore air-sampling with enhanced or standard alarm sensitivity setting for the sampling points. As a multi-channel addressable system, the VEA detector is able to divide a protected space into sampling locations, enabling the localization of a fire for a faster incident response. VEA is suitable for the protection of area where pinpoint location of fire events is essential, thus providing ideal fire detection solutions for offices, hospitals, schools, prisons, multi-storey dwellings, cabinets in data centres and warehouse racks. A wide range of features provide flexibility, enhanced connectivity and reduced total cost of ownership.

The pipes are a metric standard of 25mm external diameter with suitable adapters available for imperial to metric conversions and are designed for use with any make of low pressure aspirating type smoke detection system. Unlike some metal pipes, Vesda ABS pipework is very light in weight. This makes it easy to handle in high and difficult places where systems are often installed.

How Does Vesda Work? A Vesda detector is much like a vacuum cleaner. It sucks air from the protected environment via purpose built aspirating pipe and fittings and samples the quality of air passing through the Vesda detection laser chamber. Vesda detectors are available in a variety of models to accommodate a broad range of environments and applications. From small to very large, open spaces and from the cleanest to the dirtiest environments, Vesda provides reliable, high-sensitivity, very early warning smoke detection.

Typical Applications Vesda delivers absolute protection across a wide range of industries and applications:Apartments, Hotels, Shops, Offices (and other accommodation), Correctional Facilities, Clean Rooms, Cold Storage, Hospitals and Health care, Insurance, Nuclear Facilities, Portable Switch Rooms, Power Generation, Records Storage, Transportation, Wind Power Generation & Warehousing.

A cost-effective Aspirated Smoke Detection (ASD) solution that meets the unique needs of numerous small area applications of up to 100m² (1,000 sq. ft).

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

The VEU series of aspirating smoke detectors are the premium detectors of the VESDA-E range. An ultra-wide sensitivity range; 15 times greater than the VESDA VLP, and provision for more sampling holes provide and increased coverage in high airflow applications by at least 40%. Considerably longer linear pipe runs and extended branched pipe network configurations cater perfectly to applications with higher ceilings providing an increased coverage by up to 80% whilst allowing convenient detector mounting for ease of service and maintainance. A range of revolutionary new features provide unsurpassed detection performance, flexibility, field programmability, connectivity and reduced total cost of ownership.

Vesda-E Vep

Vesda-E VLQ

224

Vesda-E Veu

|

The VESDA-E VEP series of smoke detectors bring the latest and most advanced detection technology to provide very early warning and the best nuisance alarm rejection to a wide range of applications. Built on the Flair detection technology and years of application experience, VEP detectors deliver absolute calibration for lifetime performance and a range of revolutionary new features that deliver user value.

w: deta.co.uk


F/VEP-A10-P

F/VEA-040-A00

• • • • • • • • • • • • • • • • • • • •

F/VEU-A00 Product Code

Description

Reliable early detection warning Assured performance in challenging environments Superior suppression actuation Easy & low maintenance Reliable detection in large open spaces Flexible solution in any facility type Wide coverage Action before suppression Provides time for orderly evacuation Avoids risks to precious assets Business continuity Active air sampling Where smoke detection is a challenge Tolerant of harsh environments Detects smoke in a varied range of conditions and applications Prevents nuisance alarms Overcomes the effects of smoke dilution Security and inmate safety Vandalism prevention EN 54-20 compliant

225

Product Code

Description

Accessories F/CH/PIP-002

25mm jointing socket

F/CH/PIP-003

25mm socket union-screw tight-unit price

F/CH/PIP-005

90 degree bend

F/CH/PIP-006

45 degree bend 25mm

F/CH/PIP-007

End cap 25mm

F/CH/PIP-008

T piece 25mm

F/CH/PIP-009

Pipe clip

F/CH/PIP-012

Solvent cement

F/CH/PIP-014

Pipe cutters

F/CH/PIP-015

Flush sample point – head only

F/CH/PIP-016

Trunk adaptor

F/CH/PIP-059-001

Flush sample point assembly

F/CH/PIP-059-007

Conical sampling point

F/CH/PIP-221-035

10mm capillary pipe

Piping

F/CH/PIP-222-059

Discrete end cap

F/CH/PIP-001/1M

F/CH/VSP-005

Filter for all Vesda detectors

F/VEA-040-A00

VESDA-E VEA-40 Detector with LEDs. Max pipe length 40 x 100m

F/VEA-040-A10

VESDA-E VEA-40 Detector with 3.5” Display Max pipe length 40 x 100m

VESDA-E VEU

F/VEU-A10

VESDA-E VEU with LED’s. Max pipe length 4 x 100m or 800m with branches VESDA-E VEU with 3.5” Display. Max pipe length 4 x 100m or 800m with branches

VESDA-E VEP F/VEP-A00-P

F/VEP-A10-P

GUARANTEE

F/VEU-A10

VESDA-E VEA

F/VEU-A00

2-YEAR

Aspirating Equipment

EN54

VESDA-E VEP with LEDs, 4 pipe. Max pipe length 4 x 70m or 560m with branches VESDA-E VEP with LEDs, 3.5" Display, 4 pipe. Max pipe length 4 x 70m or 560m with branches

1 x 3m length of pipe

PSU’s F/CH/VPS-215

1.5A PSU – Vesda (requires 2 x B/12V/7AH/ SLA batteries)

F/CH/VPS-220

2A PSU – Vesda (requires 2 x B/12V/12AH/ SLA batteries)

Batteries B/12V/7AH/SLA

12 Volt 7Ah sealed lead acid battery (1 block)

B/12V/12AH/SLA

12 Volt 12Ah sealed lead acid battery (1 block)

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

225


AOV Smoke Ventilation System

What is an AOV?

Example 1

AOV is simply an abbreviation for “Automatic Opening Vent”. An AOV system is a control system designed to vent air or smoke for use in natural & smoke ventilation.

You have one roof vent or window which must open when the fire alarm is triggered...

So Why Do I Need An AOV System? AOV control systems are used mainly to control the ventilation of smoke in a fire. Changes to building regulations were made due to the results of investigations into smoke inhalation. When a detector or call point is triggered an AOV control system will open actuators, windows or vents to create ventilation. This clears smoke for people leaving the building and vents smoke out of the area that has been triggered. The provisional standard that is now available for reference is EN:12101. Smoke Control Systems are required in multi-storey residential buildings, hotels, student accommodation and principally to protect the stairs to assist escape in the event of a fire, in compliance with the recommendations of Approved Document B and BS 9991:2015. In multi-storey residential buildings, the main escape route is always via common corridors and/or lobbies into the stairs. That aim is to keep stairs reasonably free of smoke and to improve conditions in corridors and lobbies opening onto the stairs.v

In this situation you have 1 zone. You need to first see how the roof vent or window operates. If it is manual opening then you will need to add an AOV actuator which can be triggered to open or close. If there is already a fire system in place there may be smoke detectors fitted. In this situation you can link an AOV single zone to your fire system which will trigger when smoke is detected in that area. The AOV actuator when triggered will open, when reset it will close. Yellow call points can be added for override or system test. (If there is no fire system in place a detector can be fitted to trigger the system.)

Example 2 You have 4 floors, a window on each, and a vent for a shaft on the roof... This situation would leave you with 5 zones. Here you would use an AOV multi zone panel which will be able to open/close each zone independently. Under this condition it may be that the vent should open together with any zone that is triggered. (A roof vent will be on a smoke shaft or stairwell. Opening it together with a window will then create a chimney effect clearing smoke.) In this case you can set the AOV multi zone with zone 1 as a “master”. A simple solution that will then trigger zone 1 together with any of the zones 2 – 5.

How Do I Decide Which AOV System To Fit?

Again you would then need to add an actuator to each window/ vent and either link to your existing fire system or add call points & smoke detectors to the AOV multi zone system to trigger.

You first need to decide what items you need to control on your system. You should work out how many items will need to open separately & then class each one as a zone. See the following examples:

226

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


2-YEAR GUARANTEE

System Layout & Wiring The diagram below shows the typical system architecture for a single zone panel system. The AOV can be triggered by an input from a fire alarm system or dedicated smoke detectors.. Product Code

Automatic Opening Vent System

EN54

227

Description

Control Panels

F/HCV500/0350

F/SVM/24V-5A/ BASIC

Smoke control panel 1-zone 24V-5A

F/SVM/24V-8A/ BASIC

Smoke control panel 1-zone 24V-8A

MULTIZONE

Please contact us for details on available multizone systems

Chain Drives F/HCV500/0350

Chain drive 24Vdc, 500N, 350mm

F/HCV500/0600

Chain drive 24Vdc-500N-600mm

F/HCV500/0800

Chain drive 24Vdc, 500N, 800mm

F/HCV500/1000

Chain drive 24Vdc, 500N, 1000mm

F/GE8829

Bracket for above

Fireman’s Controls

F/HCV500/0600

F/WSK/321/0005/61

Break glass, SVM, orange

Smoke Detectors (55000-317) Optical Smoke detector with base

F/CHSM/P

A

Cable Types: A – 2-core FP200 1.5MM B – 6-Core FP200 1.5MM (Can be made up from 2-core + 4-core ETC)

B

AOV Window Combined clear free area of 1.0m² required

Top level call point adjacent to AOV A

1st Floor B

Ground Floor

Entrance level call point for fire service use

The AOV window can be triggered by dedicated smoke detectors or an input from a separate fire detection system.

A

F/SVM/24V-5A/BASIC

Volt free changeover contacts from fire alarm system (if required)

230V 5A Switched Fused Spur

t: 0845 884 7000

|

F/WSK/321/0005/61

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

227


Firebeam - 2

EN54

2-YEAR GUARANTEE

Ideal For Protecting Areas Such As: • Warehouses • Theatres • Sport centres

• Places of worship • Atriums • Supermarkets

Mid Range Distance Kits (70-140 Metres)

Product Code

Description

Self Adjusting Beams

Designed to cover distances between 70 and 140 metres, the Fire Beam Mid Range Kit is a clear acrylic plate with 3 extra reflectors attached.

Long Range Distance Kit (140-160 Metres) Designed to cover distances between 140 and 160 metres, the Fire Beam Long Range Kit is a clear acrylic plate with 8 extra reflectors attached.

F/CHBM/SA/2

Self adjusting beam detector 7 – 70m range

F/CHBM/70/KIT/2

70 – 140m range kit for CHBM/SA/2

F/CHBM/140/KIT/2

140 -160m range kit for CHBM/SA/2

F/CHBM/ADAPTER

Unistrut Adapter for CHBM/SA/2

F/PSU24/1.5/BMEN54

Power supply

F/CH/MSM/95

55000-76APO Mini Switch Monitor (For use on addressale systems)

Anti-Fog Kits

Simply add the Single Reflector that is provided with the standard Fire Beam into the spare space on the plate using the screws provided. Firebeam is designed to fully comply with EN 54 part 12. and exceeds European standards, in particular BS5839 part 1.

SP/CHBM/70KIT

Anti-Fog 70-140m range kit for CHBM/ SA/2

SP/CHBM/140/KIT

Anti-Fog 140-160m range kit for CHBM/ SA/2

Addressable beam detectors

Distance & Position Guidelines

F/CHBM/R/50/95

55000-268 Apollo 50m beam detector

F/CHBM/R/100/95

55000-273 Apollo 100m beam detector

A roof is considered flat unless the height of the apex is greater then 0.6m. If the roof is fl at fi rebeam system can be placed anywhere under the roof between 0.3m and 0.6m below the roof, up to a maximum height of 40m from the fl oor. Firebeam has a detection area of 7.5m either side of the beam. If the roof is considered to have an apex, place the fi rebeam system 0.3m to 0.6m down from the top of the apex, up to a maximum height of 40m from the fl oor. The maximum protected area either side of the beam can be extended by 1% for every degree of roof pitch, see the example. F/CH/MSM/95 Mini Switch Monitor 0.3m – 0.6m

Extra coverage due to apex angle 10°

40m max 2.7m min

0.3 – 0.6m

15 + (15 x 10%) = 15m + 1.5m = 16.5m

8.25m

8.25m

16.5m detection area

Field of view should be a 50cm radius from the centre or the beam Wall

Flat roof 0.3 – 0.6m

Please note: For further information on this specilaist range contact our sales team on 0845 884 7000.

t: 0845 884 7000

|

Wall

You should always position the beam at least 0.5m away from any protrusion

15m detection area

228

Min 0.5m

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Alarmline Cable

2-YEAR

• • • • • • • • • •

Environmental -65˚C to +200˚C 5 detection temperature ranges from 61˚C to 238˚C Simple interface to any BS5839 system, FM approved Fully monitored Twin-conductor switching heat sensing cable Effective monitoring at precise point of risk Economical, reliable and durable detection Simple and easy to install Applied where other types of fire detection are unsuitable Ideal for dirty or harsh environments such as: Escalator pits, Pipe and cable tunnels/trays, Conveyor belts, Petro chemical, Freezers cold rooms, Within racking

Fire System Accessories

GUARANTEE

229

Right, top to bottom: Pipe clip (F/ACAC-CP-025) is made from stainless steel, T clip (F/ACA-CT/025).

Product Code

Description

Cable F/AD68-0100

63˚-70˚C Alarmline cable (68˚C nominal) * Supplied in 100m, 200m, 500m & 1000m lengths only

F/AD88-0100

79˚-95˚C Alarmline cable (88˚C nominal) * Supplied in 100m, 200m, 500m & 1000m lengths only

F/AD105-0100

101˚-108˚C Alarmline cable (105˚C nominal) * Supplied in 100m, 200m, 500m & 1000m lengths only

F/AD185-0100

177˚-189˚C Alarmine cable (185˚C nominal) * Supplied in 100m, 200m, 500m & 1000m lengths only

Accessories F/ACAC-CP-025

P clip for use with Alarmline cable – Pack of 25

F/ACA-CT-025

T clip for use with Alarmline cable – Pack of 25

Acoustic Door Holder - Wire Free • • • • • •

Comes complete with batteries Digital, acoustically triggered, battery powered, wireless magnetic door holder Mounts behind door avoiding accidental damage – no wiring required Battery life indication and low battery warning Can be set to automatically release daily at set times CE marked under the CPD – Holding force 200N

Product Code

Description

F/CHDR/AUDIO

Acoustic wireless door holder triggered by fire alarm sounder

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

229


Interface Relays

Product Code

Description

S/E15/A

24V 5A double pole relay

S/E60/A

12Vdc 5A double pole

S/E55/A

230V 5A double pole relay

F/CH/HDR/5

24 V 5A double pole relay in heavy duty box

S/CH/BF376

24V 5A Relay on single gang plate

Our heavy duty relay units are designed for interfacing heavy loads such as door release units or plant shut down equipment with fire alarm systems

With a flame retardant, low profile ABS plastic body, Installation is made simple, with knockouts provided for entry of surface mount conduit, there is ample room to connect external wiring to the 4.0mm terminals. Each door retainer is fitted with a spring loaded release pin mounted centrally within the electro-magnet. On power off, the release pin then ensures that the fire door is pushed away from the electro-magnet. Additional accessories are available, including floor brackets, chains and additional keeper plates Flame retardant, low profile ABS plastic body All door retainers are designed to comply to the latest requirements of EN 61000-3-2, EN 50081-1, EN 60950 and EN 1155

Please note: The plate is about 1/2 the size of the box in the current picture.

Wall Mounted Door

F/CHDR/BK

• • • Right: F/CHDR/24

F/CHDR/CHAIN

230

Product Code

Description

F/CHDR/24

24V magnetic door release

F/CHDR/240

240V magnetic door release

F/CHDR/BK

Door release mounting bracket

F/CHDR/CHAIN

1m chain for magnetic door release plates

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


• • • • • •

Fire System Accessories

Power Supply Units for Door Closers / Releases 27V DC nominal output Remote control of output Choice of switching options: Closing of Normally Open Contact/ Application of an external 24V DC supply LED Indication: Mains Status/Output Fuse Failure Mains Transient

231

Typical Applications • • •

Product Code

Description

F/CHDR/PSU/2

PSU 24V 2A in enclosure

F/CHDR/PSU/4

PSU 24V 4A

Opening of a normally closed volt-free contact Closing of a normally open volt-free contact Application of an external 24V DC supply such as a sounder circuit

Special Function Call Point Units

F/CH/FVE

• • • • • • • • •

F/CH/EDR/FLEX

F/CH/PC

F/CH/ER

Unique ‘Plug & Go’ installation concept Total ‘Flex-Ability’ in the choice of operating element Anti-Tamper facility Enhanced aesthetics Backward compatibility Proven design approved and certified to EN5411 Use of glass or resettable plastic element Alarm indicator and 240v changeover contacts Back box with fixing screws

Product Code

Description

F/CH/PC

Surface break glass – blue no resistor

F/CH/EDR/FLEX

Surface break glass – green no resistor

F/CH/ER

Surface break glass – yellow no resistor

F/CH/FVE

Surface vent extract unit – yellow no resistor – 3 POS key switch

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

231


Fire Alarm Switched Fused Spur • • • • •

Both the Live and Neutral supply is switched Integral fuse, which cannot be removed without taking the cover off The supply can only be isolated by means of a keylock switch The key is removable in both ON/OFF positions A Green LED is use

Product Code

Description

F/CHFA/SFS

Key operated double pole switched fused spur

Call & Key Point Covers

• • • •

F/CHBGC/ KIT Surface Break Glass Cover (Break Glass Unit not included)

Constructed from tough clear polycarbonate Easy to install, can retrofit over existing devices Includes integral sounder, powered by a 9V PP3 battery (included) Protects equipment from accidental operation, vandalism, product misuse, dust and weather Flush and surface mounted versions available

Key Point Cover Features • • •

Sturdy ABS plastic key holder secures and provides visible storage of emergency keys Supplied with printed glass (perspex) that reads “BREAK GLASS FOR KEY” Constructed from robust ABS plastic casing with a crystal styrene window to protect your emergency keys until needed

Product Code

Description

Call Point Cover

F/KEY BOX Break Glass Key Box

F/CHBGC/KIT

Heavy Duty Flush and surface Break Glass Cover Kit

F/CHBGC/KIT/S

Heavy Duty Flush and surface Break Glass Cover Kit with Sounder

Accessories F/CHSG

10 pack spare glass

Key Point Cover

232

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

F/KEY BOX

Break glass key box

F/KEY BOX GLASS

Spare glass for key box

w: deta.co.uk


• • • • • •

Used to show operation of hidden smoke detectors Supply voltage range – 5-28Vdc IP Rating – F/CHRI/60 – IP 42 & F/CHRI/C – IP66 Current – 24mA Weight – F/CHRI/60 – 38g & F/ CHRI/C – 117g It can be used to link into either addressable, conventional, 2-wire & 4-wire fire detection system arrangements

Product Code

Description

F/CHRI/60

Remote indicator

F/CHRI/AS

AlarmSense remote indicator (Round)

Fire System Accessories

Remote Indicators

233

F/CHRI/60

Power Supply Units EN54 Compliant 1.5A PSU Features • • • •

24V 1.5A EN54-4/A2 Boxed PSU VdS certified to EN54-4/A2 Batteries: 2 x 12V Min.2Ah, Max.3.4Ah 380 x 235 x 96mm plastic enclosure

EN54 ComplIant 3A PSU Features • • • •

Product Code

24V 3A EN54-4/A2 Boxed PSU LPCB certified to EN54-4/A2 Batteries: 2 x 12V Min.7Ah,Max.12Ah 404 x 404 x 110mm metal enclosure

Description

NON EN54 Compliant Power Supply Units F/PSU/12/1/BM

12V 1A power supply unit – battery monitored (Max. 1x B/12V/7AH/SLA)

F/PSU/12/2/BM

12V 2A power supply unit – battery monitored (Max. 1x B/12V/7AH/SLA)

F/PSU/12/3/BM

12V 3A power supply unit – battery monitored (Max. 1x B/12V/7AH/SLA)

F/PSU/12/5/BM

12V 5A power supply unit – battery monitored (Max. 1x B/12V/7AH/SLA)

F/PSU/24/1/BM

24V 1A power supply unit – battery monitored (Max. 2x B/12V/7AH/SLA)

F/PSU/24/2/BM

24V 2A power supply unit – battery monitored (Max. 2x B/12V/7AH/SLA)

F/PSU/24/3/BM

24V 3A power supply unit – battery monitored (Max. 2x B/12V/7AH/SLA)

F/PSU/24/5/BM

24V 5A power supply unit – battery monitored (Max. 2x B/12V/7AH/SLA)

EN54 Compliant Power Supply Units F/PSU24/1.5/BMEN54

EN54 compliant 24V 1.5A power supply unit – battery monitored (Min. 2x B/12V/3.2AH/SLA – 12V 3.2AH)

F/PSU24/3/EN54/1

EN54 compliant 24V 3A power supply unit – battery monitored (Min. 2x B/12V/12AH/SLA – 12V 12AH)

Batteries B/12V/2.1AH/SLA

12 Volt 2.1Ah sealed lead acid battery (1 block)

B/12V/2.3AH/SLA

12 Volt 2.3Ah sealed lead acid battery (1 block)

B/12V/2.8AH/SLA

12 Volt 2.8Ah sealed lead acid battery (1 block)

B/12V/7AH/SLA

12 Volt 7Ah sealed lead acid battery (1 block)

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

233


Solo Detector Testing Aerosols

F/CH/SOLOA5

Removal & Cleaning

F/CH/SOLO/CO

Testing Kits

F/CH/SOLOA5

Smoke Testing

Telescopic Poles

Functional checking is accomplished by introducing a smoke, or simulated smoke, stimulus from the protected area through the vents of a detector to the sensor(s). It is required by all national standards around the world and testing by electronic means that do not involve this test is not sufficient to comply.

You have 4 floors, a window on each, and a vent for a shaft on the roof...

Heat Testing Functional checking of heat detectors, with a genuine heat source, is now required by major national standards around the world. Testing with heat sources not designed for the purpose can be both dangerous and damaging. The Solo range of heat detector testing equipment is designed specifically for purpose and provides a professional solution.

This situation would leave you with 5 zones. Here you would use an AOV multi zone panel which will be able to open/close each zone independently. Under this condition it may be that the vent should open together with any zone that is triggered. (A roof vent will be on a smoke shaft or stairwell. Opening it together with a window will then create a chimney effect clearing smoke.) In this case you can set the AOV multi zone with zone 1 as a “master”. A simple solution that will then trigger zone 1 together with any of the zones 2 – 5. Again you would then need to add an actuator to each window/ vent and either link to your existing fire system or add call points & smoke detectors to the AOV multi zone system to trigger.

Co Testing Many multi-sensor fire detectors detect carbon monoxide (CO) as well as smoke and / or heat. Under international codes and standards the CO cell needs to be functionally tested with a CO stimulus from the protected area through the detector vents to the sensor. Solo CO – used in conjunction with Solo 330 / 332 dispensers – provides a safe way of achieving this with CO concentration levels high enough to activate an alarm, but low enough not to pose danger to user health.

Testing Kits AOV is simply an abbreviation for “Automatic Opening Vent”. An AOV system is a control system designed to vent air or smoke for use in natural & smoke ventilation.

Removal & Cleaning You have one roof vent or window which must open when the fire alarm is triggered... In this situation you have 1 zone. You need to first see how the roof vent or window operates. If it is manual opening then you will need to add an AOV actuator which can be triggered to open or close. If there is already a fire system in place there may be smoke detectors fitted. In this situation you can link an AOV single zone to your fire system which will trigger when smoke is detected in that area. The AOV actuator when triggered will open, when reset it will close. Yellow call points can be added for override or system test. (If there is no fire system in place a detector can be fitted to trigger the system.)

234

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Maintenance Test Equipment

Solo Detector Testing Kit Selector *Using Solo A5 Smoke Detector Tester Aerosol. **Using Solo C3 CO Detector Tester Aerosol

Product Code

Smoke Testing*

Heat Testing

Co Testing**

F/CH/SOLO/808

Access Height (Approx. Max.)

461 Cordless Heat Tester

424 Mains Heat Tester

610 Carrying Bag

760 Battery Baton

726 Battery Charger

235

4m

F/CH/SOLO/809

6m

F/CH/SOLO/810

2.5m

F/CH/SOLO/811

6m

F/CH/SOLO/812

6m

F/CH/SOLO/814

8.2m

F/CH/SOLO/822

6m

F/CH/SOLO/823

9.3m

Product Code

330 Aerosol Dispenser

100 Access Pole

101 Extension Pole

108 Access Pole

200 Removal Tool

F/CH/SOLO/808 F/CH/SOLO/809 F/CH/SOLO/810 F/CH/SOLO/811 (x2)

F/CH/SOLO/812 F/CH/SOLO/814 F/CH/SOLO/822 F/CH/SOLO/823

Product Code

(x2)

Description

Channel Economy Option For Detector Testing F/CH/SMOKESABRE-01-001

Handheld spray for generic detector testing 150ml

Solo Smoke Testing F/CH/SOLO/330

Smoke dispenser

F/CH/SOLOA5

Solo test smoke aerosol 250ml

Product Code

Description

Solo Telescopic Poles F/CH/SOLO/100

Telescopic pole (6m reach)

F/CH/SOLO/101

Extension pole (1.13m length)

F/CH/SOLO/108

Telescopic pole (3.5m reach)

Solo Accessories F/CH/SOLO/610

Carrybag (including pole bag)

Solo Testing Kits

Solo Heat Testing Mains heat tester (110V)

F/CH/SOLO/808

Smoke detector test starter pack

F/CH/SOLO/424

Mains heat tester (220V)

F/CH/SOLO/809

Smoke detector test starter pack

F/CH/SOLO/461

Cordless heat tester kit

F/CH/SOLO/810

Starter kit for testing smoke detectors

F/CH/SOLO/460

Cordless heat tester (head unit only)

F/CH/SOLO/811

Smoke kit 6m for testing and removing

F/CH/SOLO/812

Smoke kit 8.2m for testing and removing

F/CH/SOLO/760

Battery baton

F/CH/SOLO/814

Smoke/mains heat kit 6m for testing

F/CH/SOLO/726

Battery charger

F/CH/SOLO/822

Cordless – Smoke / heat kit 6m for testing

F/CH/SOLO/823

Cordless – Smoke / heat kit 9m for testing

F/CH/SOLO/423

Solo Co Testing F/CH/SOLO/CO

Solo CO fire detector tester aerosol

Solo Removal & Cleaning F/CH/SOLO/200

Removal tool

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

235


Evacuation System BS 8629:2019 Evacuation Alert Control & Indicating Equipment (EACIE) Following recent fire in numerous high rise buildings, BS 8629:2019 now gives guidance on Evacuation Alert Systems which are recommended in blocks of flats to assist the Fire and Rescue Service (FRS) in evacuating part or all of a building in an emergency. In domestic buildings with a storey more than 18m above ground level, an evacuation alert system should be provided to enable the fire and rescue services to initiate operation of fire alarm sounders within each dwelling on any single floor, multiple floors and the entire building, according to circumstances. Separate to the fire alarm system, the EACIE system allows the fire brigade to evacuate any or all zones at the flick of a switch. Toggle switches and LED indication will make viewing evacuation zone status and implementing evacuation strategies quick, simple and straightforward. Each EACIE panel is housed in its own security-rated enclosure with a BS EN 1303-compliant lock and key mechanism for exclusive access by the fire and rescue service – ensuring minimal risk of unauthorised use. The EACIE will work with hard-wired, radio and/or hybrid systems.

Is it Mandated? On 30 October 2019 the Grenfell Tower Inquiry Phase 1 report was published, and contained recommendations that: “… all high-rise residential buildings (both those already in existence and those built in the future) be equipped with the means for fire and rescue services to send an evacuation signal to the whole, or a selected part, of the building by means of sounders or similar devices.” The Scottish Government added this requirement to their Technical handbook making an EACIE compulsory is any qualifying building.

Typical Layout Additional Floors

Flat Interface Optional Visual Alarm Device

Individual Flat/Dwelling

Evacuation Sounder

Floors 1-4

Optional Additional Loops

Fault Out (To ARC)

Located in corridor outside dwelling Loop 1

Mains In

Optional fault tolerant network to connect multiple tower blocks to a control room

Please note: As Each system needs to be individually designed, please contact us for further information 236

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

Isolated connection


Maintenance Test Equipment

Talentum Flame Detectors

237

• • • • •

Available for indoor and outdoor areas Flame-proof, explosion-proof and high ambient temperature options Internal self-test capability giving the highest immunity to false-flame sources Detects invisible flames from fuels such as Hydrogen and other inorganic fuels Immune to the effects of wind, draughts and sunlight

Where Talentum® Performs Agriculture | Automotive | Aircraft Hangers | Aeronautical Repair | Bed Fillings | Biomass Storage & Handling | Chemical Plants | Coal Racks | Generators | High Voltage Equipment | LNG/LPG Production | Military & Marine | Nuclear and Non-Nuclear Power Plants | Petrochemical | Pharmaceutical Production | Printing | Refineries | Spray Booths | Storage Tanks | Tunnels | Waste Recycling | Woodworking

Product Code

Description

F/FFE-16581

Talentum Dual IR. High immunity to flase sources. Suitable for indoor areas only

F/FFE-16571

Talentum Dual IR. Intrinsically safe (IS) for hazardous areas. High immunity to false sources. Suitable for indoor areas only

F/FFE-16511

Talentum Dual IR. Flameproof (Exd) for hazardous areas. High immunity to false sources. Suitable for indoor areas only

F/FFE-16589

Talentum Triple IR. Excellent immunity to false sources. suitable for indoor or outdoor areas.

F/FFE-16579

Talentum Triple IS IR, Intrinsically Safe (IS) for hazardous Area Excellent immunity to false sources. Suitable for indoor or outdoor areas.

F/FFE-16519

Talentum Triple IR, Flameproof (Exd) for hazardous areas. Excellent immunity to false sources. Suitable for indoor or outdoor areas.

F/FFE-16591

Talentum UV/IR2. Highest immunity to false sources. Suitable for indoor or outdoor areas.

F/FFE-16521

Talentum UV/IR2 Flame Detector. Flameproof (ExD). Highest immunity to false sources. Suitable for indoor or outdoor areas.

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

237


Equality Act & Assistance Products Channel’s Equality Act and Assistance Products provide a versatile, aesthetically pleasing and cost-effective complement to their wellestablished range of alarms. With solutions to suit any complexity or scale, Channels experienced designers are on hand to provide support and expertise where required.

238

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Contents Induction Loop Systems Toilet Alarm Kits Nurse Call Systems Refuge Alarm Systems

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

240 - 243 244 - 247 248 - 253 254 - 259

|

w: deta.co.uk

239


Induction Loop Amplifier Kits

2-YEAR GUARANTEE

A range of current mode induction loop amplifier designed to meet or exceed the requirements of BS7594 and EN60118-4 when correctly installed. Ideal for the following applications:

Product Code

• • • • • • • •

Meeting rooms Lecture theatres Shops Churches Schools TV lounges Health and fitness club Other small to medium sized applications

Description

1.5m2 Counter Induction Loop Amplifier Kit I/CHIL/103C

Counter hearing loop kit with PDA 103 amplifier, AMT microphone and TX2 counter loop

50m2 Induction Loop Amplifier Kits I/CHIL/103L

Small room induction loop kit complete with AMT tie/desk microphone, 30m of loop cable and x2 induction loop stickers

I/CHIL/103R

Small room induction loop kit complete with APM omni-directional plated microphone, 30m of loop cable and and x2 induction loop stickers

Pda 200e Amplifier I/CHIL/200E

200m2 Wall mounted loop amplifier

200m2 Induction Loop Amplifier Kits I/CHIL/K1

Meeting room loop induction kit complete with 1x I/CHIL/200E, 1x I/CH/APM plated microphone and 1x loop fitted sticker

I/CHIL/K2

Lecture room loop induction kit: complete with 1x I/CHIL/200E, 1x I/CH/AMT tie/desk microphone, 1x I/CH/AML lectern microphone, 2x I/CH/APJ outreach plates and 1x loop fitted sticker

I/CHIL/K3

TV & music room loop induction kit complete with 1x I/CHIL/200E, 1x I/CH/AMH handheld microphone, 1x I/CH/APS scart lead, 1x I/CH/APJ outreach plate, 1x I/CH/APL outreach plate, 1x loop fitted sticker

Testing Equipment I/CH/FPROK/1

Fosmeter Pro Induction loop test kit complete with signal generator

Professional Induction Loop Phase Shifting Amplifiers

Product Code Product Code

Description

PDA/D Phase Shifting Dual Hearing Loop Amplifiers Class D output Type D – phase shifted amps for low overspill and large areas

PDA/S Phase Shifting Dual Hearing Loop Amplifiers Type S-Standard perimeter loops for large areas

240

Description

I/CHIL/5/SD

“200m2 free-standing PDA/S hearing loop amplifier, 4.75A”

I/CHIL/PDA5/DD

“200m2 free-standing PDA/D phasedshifting hearing loop amplifier, 2 x 3.25A”

I/CHIL/5/SW

“200m2 wall-mounting PDA/S hearing loop amplifier, 4.75A”

I/CHIL/5/DWA

“200m2 wall-mounting PDA/D phasedshifting hearing loop amplifier, 2 x 3.25”

I/CHIL/7/SD

“500m2 free-standing PDA/S hearing loop amplifier, 7.5A”

I/CHIL/7/DD

“500m2 free-standing PDA/D phasedshifting hearing loop amplifier, 2 x 5A”

I/CHIL/7/SW

“500m2 wall-mounting PDA/S hearing loop amplifier, 7.5A”

I/CHIL/7/DW

“500m2 wall-mounting PDA/D phasedshifting hearing loop amplifier, 2 x 5A”

I/CHIL/11/SD

“1000m2 free-standing PDA/S hearing loop amplifier, 11A”

I/CHIL/11/DD

“1000m2 free-standing PDA/Dhased-shifting hearing loop amplifier, 2 x 7.5A”

I/CHIL/11/SW

“1000m2 wall-mounting PDA/S hearing loop amplifier, 11A”

I/CHIL/11/DW

“1000m2 wall-mounting PDA/D phasedshifting hearing loop amplifier, 2 x 7.5A”

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Induction Loop Systems

Outreach Plates

241

Product Code

Description

I/CH/APJ

3.5mm mono jack plate for connection of CH/AMT, CH/AMH, CH/AML or CH/AMD microphones

I/CH/APL

Dual phono line level audio plate for connection of CH/APS SCART lead or other line level audio feeds

I/CH/APQM

6.35mm stereo jack plate for connection of CH/AMR/L or H radio mic.

I/CH/APQL

6.35mm stereo jack plate for the connection of line level feeds from mixing desks, etc.

I/CH/APXM

XLR mic level plate for connection of CH/AMP microphone

I/CH/APXL

XLR line level plate for connection of mixing desk line level feeds

I/CH/APM

Omni – directional plated microphone for wall/ceiling/desk mounting

I/CH/BELDEN/25

25m of Belden 8723 audio cable

I/CH/FLAT/2005

100m x 1.0mm copper tape (flat loop)

I/CH/FLAT/3005

100m x 1.5mm copper tape (flat loop)

Please note: Our I/CHIL/PL1 and I/CHIL/DOM amplifiers do not have outreach sockets and that our I/CHIL/MK1 amplifier can have a maximum of three outreach plates connected to it.

Microphones

Product Code

Description

I/CH/AMP

Professional handheld microphone for CHIL/200E or CH/APXM plate (requires CH/AXLR lead)

I/CH/AMR

Levalier radio microphone complete with microphone, receiver, transmitter, PSU. Connects to CHIL/200E or CH/APQM outreach plate

I/CH/APM

Omni directional plated microphone for wall/ceiling mounting, connects to CHIL/ML1, CHIL/102, CHIL/200E

I/CH/AMD

Desktop microphone for CHIL/ML1, CHIL/DOM, CHIL/102, CHIL/200E, CHIL/PL1 or CH/APJ outreach plate

I/CH/AML

Lectern microphone for CHIL/ML1, CHIL/DOM, CHIL/102, CHIL/200E, CHIL/PL1 or CH/APJ outreach plate

I/CH/AMR/H

Handheld radio microphone c/w mic, receiver, transmitter, psu. Connects to CHIL/200E or CH/APQM outreach plate

I/CH/AMT

Tie/desk microphone for CHIL/ML1, CHIL/DOM, CHIL/102, CHIL/200E, CHIL/PL1 or CH/APJ outreach plate

I/CH/PRO45

High Quality hanging ambient microphone

Please note: All microphones are supplied with a connection lead apart from the I/CH/AMP. If using an AMP, a range of connection leads are available.

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

241


Portable Induction Loop Kits

2-YEAR GUARANTEE

Attractively designed in tough ABS plastic, the I/CHIL/PL1 portable induction loop system is a truly portable and extremely durable audio frequency induction loop system, packed full of features and available at a very competitive price. Fully compliant with BS7594 and EN60118-4, it is ideal for use in schools, shops, nursing homes, leisure centres, hotels, banks, GP surgeries, reception desks and many other private, public and civic applications. • • • • • • • •

Indicators provided for power on, input level, charging required and charging in progress I/CHIL/PL1 kit includes PL1 amplifier, plugtop charger, “induction loop available” sticker and wall bracket I/CHIL/PL3 kit includes PL1 amplifier complete with battery & integral microphone, plugtop charger and ‘AFILS available’ sticker Dimensions: 300mm (H) 250mm (W) 100mm (D) FPROK1 kit includes Fosmeter Pro, 1 x Audio Signal Generator, 2 x protective pouch, 1 x 32 ohm headphones for FPRO, 2 x 9 V battery Ideal for restricted person to person contact in areas such as banks, post offices, small meeting rooms, reception desks, open plan offices and ticket booths Battery Internal 12V VRSLA (Valve Regulated Sealed Lead Acid) Weight: 1.7Kg

Product Code

Description

Induction Loop Kits I/CHIL/PL1

Portable induction loop system

I/CHIL/PL3

Portable induction loop system complete with carry case

Testing Equipment Fosmeter Pro Induction loop test kit complete with signal generator

I/CH/FPROK/1 Signs And Stickers I/CH/PIL/L

Desktop portable induction loop display sign

Counter Top Kits

2-YEAR GUARANTEE

The ML1/K counter induction loop kit is ideal for use in post offices, banks, building societies, ticket offices and reception areas. Comprising a compact wall-mounting double gang induction loop amplifier, a self-adhesive microphone and preformed counter loop, it can generate a loop listening field of 1.5m2 approx. making it ideal for counters, desktops and tables. Attractively-packaged kit includes: • • • • • • •

242

t: 0845 884 7000

|

1 x I/CHIL/ML1 wall-mounting induction loop amplifier, 1 x I/CHIL/AMT self-adhesive microphone, 1 x I/CHIL/TX2 preformed counter loop & 1 x I/CHIL/TEAR ‘loop fitted’ sticker Double-gang wall-mounting I/CHIL/ML1 amplifier fits standard 25mm back boxes and is ideal for mounting under desks, counters or table tops Fully compliant with EN60118-4 (formerly BS6083) and BS7594:1993 Installer-friendly design requires no specialist audio experience or connectors – the ML1 can be fitted by any competent electrician Can be used to help building managers and service providers comply with BS8300, the Equality Act and the Care Standards Act Dimensions 143mm(H) 83mm(W) 32mm(D) Weight 300g (amplifier only)

Product Code

Description

I/CHIL/ML1/K

Counter induction loop kit

I/CHIL/ML1

1.5m2 wall mounting double gang

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Induction Loop Systems 243

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

243


Toilet Alarm Kits - Hark The Hark Help and Assistance Response Kit is simple to install and provides peace of mind wherever an indication of 'assistance required' is called for. The unit benefits from a reassuring audible sound from within the reset unit, which confirms that assistance is on the way. Optional single or multi way repeater panels are available and a 'Call Acknowledge' option is available on the Hark+.

244

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

245


HARK™ and HARK+ Attractively designed in tough ABS plastic, the I/CHIL/PL1 portable induction loop system is a truly portable and extremely durable audio frequency induction loop system, packed full of features and available at a very competitive price. Fully compliant with BS7594 and EN60118-4, it is ideal for use in schools, shops, nursing homes, leisure centres, hotels, banks, GP surgeries, reception desks and many other private, public and civic applications. • • • • • • • •

Only 3 points to install on a standard system, and can be simply linked and expanded to other systems Simple to expand as requirements increase Sounder within the reset unit to give audible reassurance that assistance is on the way Kits supplied with Twin pull cord rings, Braille text on the reset unit as well as a Disabled Persons sticker Multi-way remote indicator units available Assists in compliance with the DDA, BS8300 & other care standards Suitable for commercial and public buildings as well as specialist areas such as hospitals, restaurants, nursing and retirement homes Call acknowledge on Hark+

N/HARK/1 – Complete toilet alarm kit, comprising Pull cord, Reset unit, Power supply unit and Indicator finished in white polycarbonate

Additional Options The Help Alarm Response Kit can be linked to a remote multiway indicator panel (for use in a reception or staffed area). A 12 volt relay unit can be used to interface the unit to a wide range of equipment such as. • BMS • Fire alarms • Intruder Alarms • Paging transmitters Additional pull cord units can be added to the system to allow for larger rooms or multi area coverage. Please note that additional pull cords will operate and be reset by the same unit as the initial pull cord.

The Indicator Units are simple to install and meet the BS requirement for all disabled toilets to be fitted with an emergency toilet alarm. 75 db at 1metre These units can be purchased as either 1 or up to 11 indicators and come finished in either White Polycarbonate or Stainless Steel. Custom engraving is available.

The HARK Push Button can be used instead of a hanging pull cord to notify that the user is in distress.

The pull cord unit is supplied with a red plastic ring. An extra ring is supplied to conform to ‘Approved Document M’. The second ring should be fitted lower down near floor level. Activating a call is simply made by pulling the cord. This will activate the re-assurance indicator on the pull cord unit. In turn this will also illuminate the reset unit and trigger the internal sounder. At the same time the Overdoor indicator/sounder unit will illuminate and trigger it’s own internal sounder.

Reset Units

Alarm Indicator Units

Push Button

Pull Cord Units

The reset unit has a blue engraved legend ‘RESET’. When a call is activated the reset switch illuminates and the internal sounder activates. The call is reset by simply pressing the reset switch. The reset switch is supplied with Braille legend on the switch piece.

Indicator / Sounder Units The Overdoor indicator/Sounder unit is supplied with an integral Power supply unit. A fused spur should be fitted nearby and wired to this unit to provide power. The unit will illuminate and sound as soon as a call is activated. The unit will cease oncethe reset switch is pressed. HARK includes a variety of different accessories to work in compliance for a professional end result. These accessories combine modern aesthetics and high functionality providing you with the ideal solution for the most demanding installations. HARK assists with compliance with the DDA, BS8300 & other care standards.

246

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


2-YEAR GUARANTEE

Toilet Alarm Kits

HARK™ and HARK+

247

N/HARK+ – Stainless steel kit option complete with

HARK™ Indicator / Sounder units

battery back up and “call acknowledge” feature

HARK™ Pull cord units and Push Button Option

HARK™ Alarm Indicator unit in Stainless Steel finish and

Available in Stainless steel or white polycarbonate

Reset unit

Product Code

Description

Product Code

N/HARK/1

Complete kit with pull cord, reset, PSU/ Indicator

Indicator Units, Panels and Accessories

N/HARK+

Stainless steel option complete with battery back up (battery included) & Call Acknowledge option

Push Button

Description

N/HARK/RI/1

HARK 1-way indicator unit

N/HARK/RI/1/SS

HARK 1-way indicator unit stainless steel

N/HARK/RI/2

HARK 2-way indicator unit

N/HARK/RI/2/SS

HARK 2-way indicator unit stainless steel

N/HARK/1/PB

HARK 1 push button

N/HARK/RI/3

HARK 3-way indicator unit

N/HARK+/PB/SS

HARK Stainless Steel Push Button

N/HARK/RI/3/SS

HARK 3-way indicator unit stainless steel

Pull Cords

N/HARK/RI/4

HARK 4-way indicator unit

N/HARK/1/PC

HARK 1 pull cord

N/HARK/RI/4/SS

HARK 4-way indicator unit stainless steel

N/HARK+/PC/SS

HARK pull cord stainless steel

N/HARK/RI/5

HARK 5-way indicator unit

N/HARK/RI/5/SS

HARK 5-way indicator unit stainless steel

Power Supply/Indicator Units N/HARK/1/PSU

HARK 1 power supply unit

N/HARK/RI/6

HARK 6-way indicator unit

N/HARK+/PSU/SS

HARK power supply unit stainless steel

N/HARK/RI/6/SS

HARK 6-way indicator unit stainless steel

N/CHWB/BN/12V/DB

IP65 Sounder Beacon

N/HARK/RI/7

HARK 7-way indicator unit

Reset Units

N/HARK/RI/7/SS

HARK 7-way indicator unit stainless steel

N/HARK/1/RS

HARK 1 reset unit

N/HARK/RI/8

HARK 8-way indicator unit

N/HARK+/RS/SS

HARK reset unit stainless steel

N/HARK/RI/8/SS

HARK 8-way indicator unit stainless steel

N/HARK/RI/9

HARK 9-way indicator unit

N/HARK/RI/9/SS

HARK 9-way indicator unit stainless steel

N/HARK/CA

Call Acknowledge Button on remote indicators (Hark+ ONLY)

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

247


Quantec – Addressable Call System •

• • • •

Images show from left to right Quantec call point with reset button and Quantec display unit with controls

• •

Multiple call levels including standard, en suite, help required, emergency, attack, presence & attendance Tailored to suit a site’s exact operational requirements Call accept feature & Automatic call divert Illuminates overdoor lights and corridor lights Staff attendance allows staff entering rooms to log their ‘attendance’ via an infrared call point or ceiling receiver Call follower sounders (optional) Night mode allows Quantec to work in a totally different way at night, providing for fewer staff and reduced sound levels

• • • • • • •

Infrared staff protection helps protect staff against disturbed patients, intruders and aggressive visitors ‘Surveyor’ data analysis software allows the outputting of custom reports Optional paging facilities (DECT telephone capability also available) Laptop programmable system controller Minimising disturbance, with no expensive rewiring Easy to install & expand Low maintenance time and costs New for 2016 – a cost-effective expansion kit that adds true BS8300 compliant accessible toilet alarm functionality to a Quantec Addressable Call System (order code N/QT951)

1000s of Sites Are Benefitting from the Quantec Addressable Call System...

Quantec – Typical System Architecture Max. 32 x N/QT606As per system N/QT606A

N/QT608C

door contacts

N/QT607

N/QT60

N/QT607

Max. 3 x N/QT607s per master call point

N/QT608C

N/QT302RXS N/QT302RX Max. 3 x N/QT302RX s per master ceiling receiver

N/QT606

Todmorden House (Health Centre) Yorkshire

N/QT602

Programming PC N/QT602

N/Q T603

N/QT602

N/Q T606

SPINE 100m = 1.0mm2 twin and earth 150m = 1.5mm2 twin and earth 250m = 2.5mm2 twin and earth

N/QT604

240V a.c.

N/QT606

N/QT601-2

LIMB 40m = 4 core stranded alarm cable 60m = 8 core stranded alarm cable

A maximum of 10 network devices can be connected to each of the QT603’s 6 outputs

to next N/QT603

St Kentigerns (Hospice) North Wales

N/QT603

N/QT606

N/QT609

N/QT608C

N/QT422RX

Abraham Guest (Secondary School) Greater Manchester 248

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Product Code

2-YEAR GUARANTEE

Description

Panels N/QT601-2

Quantex addressable nurse call panel (requires x2 B/12V/7AH/ SLA batteries

N/CH385

Flush bezel for Quantec QT601-2

B/12V7AH/SLA

12 Volt 7Ah sealed lead acid battery (1 block)

Nurse Call Systems

Quantec – Addressable Call System

249

Display Units N/QT608C

Quantex display unit with controls

N/QT608CD

Quantex display unit with no controls

Call Points N/QT602

Quantec call point with reset button (remote socket)

N/QT602R

Quantec call point with reset button and I/R receiver (remote socket)

N/QT602M

Quantec magnetic reset/call button (remote socket)

N/QT609

Quantec call point with reset button (no remote socket)

N/QT609S

Quantec call point with reset button and sounder (no remote socket)

N/QT609R

Quantec call point with reset button and I/R receiver (no remote socket)

N/QT661

Quantec Infrared/Radio Fall sensor (requires IR or radio receiver)

Door monitoring Stations N/QT604

Quantec door monitoring station with reset button

Over Door Lights N/QT606

Quantec slave overdoor light

N/QT606A

Quantex addressable overdoor light

Addressable Sounders N/QT688

Quantex addressable sounder

Pull cord N/QT607

Quantex ceiling pull cord unit

Over Door Lights N/CH/806C

Overdoor light

N/CH/806CS

Overdoor light & sounder

Tail Lead N/CH/805C/6

6ft (1.8m) tail call lead

N/CH/805/14

14ft (4.2m) tail call lead

Magnetic Reset Key N/CH/803M

Magnetic reset key complete with keyring

Dual Action Transmitter

Quantec available in stainless steel – please contact Channel for details

N/QT412RXA

Dual action infra-red/radio transmitter (push for attack/pull for attack)

N/QT423

Configurator for N/QT412RXA

N/QT611

Universal interface (call unit)

Infra-Red Ceiling Receivers N/QT302RX

Quantec master infra-red ceiling reciever

Portable Receiver N/QT1001/S

Quantec portable receiver (pocket data pager)

Network Splitter N/QT603

Network splitter, 5 outputs - up to 60 addressable devices per splitter

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

249


Quantec – Dementia Care •

Can be configured to automatically switch lights on and off when movement is detected to safely guide patients to and from ensuite areas Provides clear and concise indication of room status data at ALL relevant Quantec displays (e.g. Bedroom 1, Bed Exit) All room/patient call activity is logged at the main Quantec Controller for optional output to our Quantec Surveyor data management software Comes with 10 pre-set patient monitoring configurations including high-intensity, medium-intensity

Image shows dementia care product family

• •

and ensuite ushering Can be easily adapted to the changing needs and ongoing behaviour patterns of Dementia and Alzheimers sufferers Many of the components shown can be easily added to existing Quantec systems All network devices are designed and manufactured in the UK

Specification Mains supply

230V A.C 50/60Hz. Max. current 350mA

Internal Power Supply

27V DC (nominal)

Max. switching current

25mA

Max. switching voltage

30Vd.c

Main Fuse

1 x 1 A HRC ceramic (20x5mm)

Battery

1 x 12V 7Ah battery

Battery Fuse

1 x 3.15 A F (20x5mm) this limits the current drawn from the battery

Weight

3.5kg (battery not included)

Product Code

Description

Product Code

Panel N/QT601-2

N/QT630 B/12V/7AH/SLA

Quantec addressable nurse call panel (requires 1x B/12V/7AH/ SLA battery) Quantec dementia care controller complete with PSU (requires 1x B/12V/7AH/SLA battery)

N/QT608CD

Quantec display unit with no controls

250

Quantec interface unit

N/QT638

Quantec PIR movement sensor requires a QT645 PIR power interface if connecting via a QT604/ QT604M/QT611

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

Quantec addressable overdoor light

N/QT302RXRS

Quantec slave IR ceiling receiver

Bed exit mat (connects to a QT636/637 interface unit)

Dual Action Transmitter

Interface Units And PIR Accessories N/QT636

Quantec slave overdoor light

N/QT606A

N/QT633

Display Units Quantec display unit with controls

N/QT606

Mats

12 Volt 7Ah sealed lead acid battery (1 block)

N/QT608C

Description

Over Door Lights, IR Receiver & LED Lamp

N/QT412RXA

Dual action infra-red/radio transmitter (push for attack/pull for attack)

N/QT423

Configurator for N/QT412RXA

N/QT611

Universal interface (call unit)

Transmitter N/QT603

|

w: deta.co.uk

Network splitter, 5 outputs – up to 60 addressable devices per splitter


2-YEAR GUARANTEE

A Medium Intensity Patient Monitoring System with Ensuite Ushering.

Enuresis (bed wet) Sensor

Triggers a call when moisture is detected in the patient’s bed

Infrared Ceiling Receiver

Picks up any help required, emergency or ‘staff attack’ calls made by a carer’s infrared transmitter

Superbright LED Light Switches on, off or dims dependent on the status of the behaviour pattern selected

Nurse Call Systems

Typical System Architecture

251

PIR Movement Sensors

Enuresis/Bed Exit

Sense patient movement and instruct the controller to switch lights on, off or dim and to raise a call dependent on the status of the behaviour pattern selected

Interface Socket

Corridor Display

Indicates the location and type of all incoming calls (as programmed)

Door Contacts

Can be set up to trigger a call when the bedroom door is opened

Room Status Controller

Allows carers to arm/isolate the system and reset any active calls. Optional door bell will trigger a call when pressed by the patient.

Benefits Of Using Quantec Dementia Care • Allows Nursing homes to offer specialist Dementia care with little additional cost • Allows Nursing homes to meet the requirements of local authority dementia care provision targets • Gives confidence to residents, relatives and staff of a safe, caring approach. • Allows residents to have a greater degree of autonomy without the need for staff assistance If you would like to know more about the Quantec Dementia Care system please contact our sales team on 0845 884 7000

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

251


Channel Call System

Images to the right (left to right) show a 10-20 zone call controller and a 30 zone panel

• •

Hard wired for total reliability – 4 to 6 core security cable is ideal for most installations Wide range of indicator panels covering 1 to 90 zones Extensive range of ancillaries including ceiling pulls, wallmounting call points, monitoring points, water resistant alert points, overdoor lights, remote sounders, relays and call latch modules

• • •

N/CC/920S

Need Some Assistance?

Simple to install, easy to operate and highly reliable All power supplies capable of 12V sealed lead acid battery charging Two levels of call – standard (constant tone) and emergency (intermittent tone) Can be used to help building managers and service providers comply with BS8300, the Equality Act and the Care Standards Act

We understand that planning an installation of a nurse call system can be difficult and the rules vary, so please check with the relevant bodies before planning. UK Rest Homes – Social Services will usually approve the installation and the standard system is normally ideal. Their main requirement is for the rest point to be within sight of the caller to ensure the call is attended to properly. UK Nursing Homes – The local health authority will usually approve the installation and the standard system may be satisfactory but some authorities will want the emergency facility. Also, some authorities only allow button operated emergency call/reset points and others require the magnetic key type.

Applications • Nursecall • Dementia Care • Staff Protection • Emergency Assistance • Cell Call • Affray Locations • Care Homes

How does it work? Depending on the type of calling devices used, the system can be set up to operate as a standard system – on which standard (constant tone) calls are generated – or an emergency system – on which standard (constant tone) and emergency (intermittent tone) calls are generated.

Planning a System The following points should be considered when designing or planning a call system. • Indicator panels • Call Points • Ancillary calling devices • Call latch modules

252

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


GUARANTEE

Product Code

Description

Panels

CALL & MONITORING POINTS N/CH/802DB & N/CH/894DKM

Sounder Unit N/CH/888D

Ceiling Pull Cord N/CH/807C

N/CC/941

1 way call panel c/w PSU & reset button

N/CC/941/SS

1 way Stainless steel call panel c/w PSU Optional battery back-up

N/CC/941/B

Battery back-up kit for N/CC/941/SS

N/CC/944

4 way call panel – (requires N/CC/930 12V 250mA PSU)

N/CC/930

12V 250mA PSU for N/CC/944

N/CC/910/S

10 way call panel c/w PSU – Surface Mounted 214W x 178H x 37Dmm

N/CC/910/F

10 way call panel c/w PSU – Flush Mounted 214W x 178H x 37Dmm (Cut out 176 x 162 x 55Dmm)

N/CC/910/ES

10 way Expansion call panel Surface Mounted 214W x 178H x 37Dmm

N/CC/910/EF

10 way Expansion call panel Flush Mounted 214W x 178H x 37Dmm (Cut out 176 x 162 x 55Dmm)

N/CC/920/S

20 way call panel c/w PSU – Surface Mounted 214W x 178H x 37Dmm

N/CC/920/F

20 way call panel c/w PSU – Flush Mounted 214W x 178H x 37Dmm (Cut out 176 x 162 x 55Dmm)

N/CC/920/ES

20 way Expansion call panel Surface Mounted 214W x 178H x 37Dmm

N/CC/920/EF

20 way Expansion call panel Flush Mounted 214W x 178H x 37Dmm (Cut out 176 x 162 x 55Dmm)

F/PSU/12/1/BM

12V 1amp Power supply (optional for 910/920 panels)

B/12V/2.3AH/SLA

12V 2.3AH sealed lead acid battery

Nurse Call Systems

2-YEAR

253

Call Points N/CH/802DB

Standard call point with button reset & remote socket

N/CH/802DM

Standard call point (magnetic reset)

N/CH/802DEM

Emergency & standard call / reset point (magnetic reset)

N/CH/804DE

Emergency call / reset point (button reset)

Water Resistant Call Points

Master water resistant alert point (magnetic reset) N/CH802DEWM

N/CH/802DEWM

Master water resistant alert point (magnetic reset)

N/CH/802DEWS

Slave water resistant alert point

Pull Cord N/CH/807C

Quantec ceiling pull cord unit

Remote Sounder N/CH/888D

Remote sounder

Over Door Lights

Over Door Light N/CH/806C

N/CH/806C

Overdoor light

N/CH/806CS

Overdoor light & sounder

Monitoring Points N/CH/894DKB

Button reset door monitoring point

N/CH/894DKM

Magnetic reset door monitoring point

Reset Units N/CH/809DB

Button reset point

Tail Lead N/CH/805C/6

6ft (1.8m) tail call lead

N/CH/805/14

14ft (4.2m) tail call lead

Pneumatic Pad

Magnetic Reset Keys

N/CH/805/AS

N/CH/803M

Magnetic reset key complete with keyring

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

253


Channel Orbital Range – Refuge Alarm System

2-YEAR GUARANTEE

Safety Regulations and the Disability Discrimination Act

4, 8, 16, & 32-Way Product Features

Part M of the UK government’s building regulations insists that all new non-domestic buildings with more than one-storey must provide refuge areas for public safety purposes.

The Orbital refuge alarm range is a disabled refuge and disabled toilet alarm system. The main panels are offered in a stainless steel finish in either a surface or flush enclosure with black screen print and glazed lockable door.

The master panel has the separate call switches and indicators for each disabled refuge location.

The panel has a built in alphanumeric blue OLED screen for disabled refuge zone description and ‘32’ disabled toilet alarm zone indication.

The disabled refuge outstations are wired in radial ‘2’ core ‘1.5’mm enhanced fire rated cable or as a loop wired ‘4’ core ‘1.5’mm enhanced fire rated cable.

A volt free changeover contact is provided for remote call in and fault reporting. A fire panel inhibit input is also fitted as standard.

Battery support 24 + 3 hours.

Fully compliant to BS5839 Pt9 and CE 2019 certified.

A simple two core cable should be wired from the disabled toilet PSU/Sounder unit to the nearby disabled refuge outstation. The refuge outstation back box is supplied with terminals for this connection

The Disability Discrimination Act (DDA) consists of several pieces of civil law that enable disabled people who feel they have been discriminated against to take action for damages against organisations or individuals should these considerations not be implemented to support their personal safety in the event of an emergency. All of Channel’s disabled refuge systems are BS9999 & BS5839 Pt9. 2010 compliant, and we offer our consultants assistance for BS5839, BS9999, as well as providing relevant specification templates. Simple and Effective – Simple and effective ‘full duplex’ two-way communication in these areas is essential, firstly to assist rescue teams in determining where assistance is required and secondly to reassure people help is on the way.

2-Way Product Features • Battery support 24 + 3 hours (emergency) • Fully compliant to BS5839 Pt9 • CE 2019 certified • Available with flush or surface mounting back box • 2 disabled toilet alarm indicators

254

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Radial Diagram Riser 2

Riser 1

Up to the 8th floor

4th floor

Riser 1

The Loop highway is protected against OPEN and SHORT circuit cable failure, allowing full system function under a fault condition.

3rd floor

255

4th floor

3rd floor

Toilet call loop interface bring back toilet call indications on the same network

1st floor

Riser 2

Up to the 8th floor

3rd floor

2nd floor

Typical schematic for a 6 line disabled refuge call system

Refuge Alarm Systems

Loop Wiring Diagram

2nd floor

2nd floor Toilet call loop interface bring back toilet call indications on the same network 1st floor

1st floor

Loop Highway ‘4’ core (+ Screen) standard fire rated cable

‘2’ core (+ Screen) standard fire rated cable

Slave to Loop Interface ‘2’ core Fire rated cable Max length 1,000m Product Code

Description

Product Code

Description

R/CH/ORB/R/ RS2/F

2 Way FLUSH Stainless steel refuge panel with disabled toilet alarm indicator – Radially wired

R/CH/ORB-LRS16-OLED-F

16 Way FLUSH Stainless steel refuge panel with disabled toilet alarm indicator – Loop wired

R/CH/ORB/R/ RS2/S

2 Way SURFACE Stainless steel refuge panel with disabled toilet alarm indicator – Radially wired

R/CH/ORB-LRS16-OLED-S

16 Way SURFACE Stainless steel refuge panel with disabled toilet alarm indicator – Loop wired

R/CH/ORB-RRS4-OLED-F

4 Way FLUSH Stainless steel refuge panel with disabled toilet alarm indicator – Radially wired

R/CH/ORB-LRS32-OLED-F

32 Way FLUSH Stainless steel refuge panel with disabled toilet alarm indicator – Loop wired

R/CH/ORB-RRS4-OLED-S

4 Way SURFACE Stainless steel refuge panel with disabled toilet alarm indicator – Radially wired

R/CH/ORB-LRS32-OLED-S

32 Way SURFACE Stainless steel refuge panel with disabled toilet alarm indicator – Loop wired

R/CH/ORB-LRS4-OLED-F

4 Way FLUSH Stainless steel refuge panel with disabled toilet alarm indicator – Loop wired

R/CH/RCO/H/ GB

Green outstation faceplate inc AFILS induction loop. (requires back box)

R/CH/ORB-LRS4-OLED-S

4 Way SURFACE Stainless steel refuge panel with disabled toilet alarm indicator – Loop wired

R/CH/RCO/H/ SS/1

Stainless steel outstation faceplate inc AFILS induction loop. (requires back box)

R/CH/ORB-RRS8-OLED-F

8 Way FLUSH Stainless steel refuge panel with disabled toilet alarm indicator – Radially wired

R/CH/RCO/S/ BB/1

Refuge Call Back Box – surface mounting (radial) – C/W Disabled toilet alarm input

R/CH/ORB-RRS8-OLED-S

8 Way SURFACE Stainless steel refuge panel with disabled toilet alarm indicator – Radially wired

R/CH/RCO/F/ BB/1

Refuge Call Back Box – flush mounting (radial) – C/W Disabled toilet alarm input

R/CH/RCO/S/L/ BB/1

Refuge Call Back Box – surface mounting (loop) – C/W Disabled toilet alarm input

R/CH/ORB-LRS8-OLED-F

8 Way FLUSH Stainless steel refuge panel with disabled toilet alarm indicator – Loop wired

R/CH/RCO/FL/ BB/1

Refuge Call Back Box – flush mounting (loop) – C/W Disabled toilet alarm input

R/CH/ORB-LRS8-OLED-S

8 Way SURFACE Stainless steel refuge panel with disabled toilet alarm indicator – Loop wired

Please note: Larger panels are also available on request should you require a larger system.

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

255


SigTel Refuge Alarm System

R/CH/EVC301RPO

• • • • • • • • • • • • • • • • • •

R/CH/EVC302GF

R/CH/EVC302S

New-look 4, 8 & 16 line master controllers with semi-recessed handsets save valuable space in crowded control rooms Enhanced networking facility allows up to 14 master controllers to be interlinked for systems of up to 224 lines New optional 224 Line Desk Controllers allow operators to communicate with up to 224 disabled refuge or fire telephone outstations from a single accessible point Optional anti-tamper enclosures available for controllers located in areas accessible to the public Wide range of ‘Disabled Refuge’ (Type B) outstations available in stainless steel or green steel (flush, surface or weatherproof options available) ‘Fire Telephone’ (Type A) outstations available in locking or non-locking red steel cabinets All outstations offer true duplex speech and can be mixed and matched to suit the application Unique ‘auto-learn’ facility allows fast system set up Devices can be named/edited using the buttons on a master controller or via an optional PC programming configurator (part no. EVC423). All extensions can be named with user-defined text of up to 15 characters Fully monitored hardware and software System operates at 24 VDC. In the event of mains failure, operation can be maintained for 24 hours (standby) and 3 hours (in use) using 2 x 12V 7 Ahr batteries Optional FiTT line tester allows cable faults to be checked prior to equipment connection Easily interfaced to accessible toilet alarm systems, hearing loop systems, strobes or CCTV activation relays Ideal for disabled refuge, fire telephone and stadium marshalling applications Perfect for hotels, shopping malls, office blocks, transport.terminals, sports stadiums, entertainment complexes, etc

What is an Emergency Voice Communication (EVC) System? An emergency voice communication system is a life safety intercom (or telephone) system designed to operate reliably in a fire alarm emergency. Its equipment and wiring must be monitored for faults that might occur prior to the emergency and its cabling and battery backup supply must ensure it keeps working during the emergency. According to BS5839 part 9, there are two types of EVC system; disabled refuge and fire telephone. They may be separate, or they may be combined into one system.

256

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Refuge Alarm Systems

SigTel Refuge Alarm System

257

R/ECU-8NT R/CH/ECU-224

R/ECU-16

R/CH/FiTT/R/CH/EVC

Disabled refuge systems

A disabled refuge system typically connects handsfree intercom outstations to a central control room and is used to inform management that someone needs immediate assistance to exit the building.

Fire telephone systems A fire telephone system is used by management (and marshals at a sports ground) and the fire service before, during and after a fire to communicate with fire marshals and fire fighters.

• •

Regulations affecting EVC systems?

The installation of an emergency voice communication system is governed by BS5839 Part 9: Code of practice for the design, installation, commissioning and maintenance of emergency voice communication systems. Disabled Refuge Systems are called for by: • Building Regulations; Approved Document B (Fire Safety); Volume 2, Section 4: Design for vertical escapes • BS9999: Code of practice for fire safety in the design, management & use of buildings; Clause 41.9 Communications; Clause 46.8 Use of refuges • Regulatory Reform Order (Fire Safety Order) Oct 2005 • Risk assessments undertaken by the responsible person must make provision for means of escape for disabled people Supplementary • Guide: Means of escape for disabled people • Equality Act 2010 (supersedes the Disability Discrimination Act) • UN Convention on the rights of people with disabilities

Fire telephone systems are called for by: BS9999`: Code of practice for fire safety in the design, management and use of buildings; Clause 24 Communication systems for fire and rescue service use London District Surveyors Association in conjunction with LFCDA Fire Safety Guide No. 3; Section 2: Fire Safety Measures London Fire and Civil Defence Authority (London Fire Brigade) Fire Safety Guidance Note Number: 30 (Rev 3) Guide to safety at sports grounds; 16.11: Telephone communications – internal Where are disabled refuges / Type B outstations required? Refuge areas are called for in all non-domestic buildings with more than one storey and they should be provided at each storey exit (i.e. each protected stairway affording egress) Examples of a refuge area include an enclosure such as a protected lobby, corridor or stairway or an area in open air such as a flat roof, balcony, podium or similar place which is sufficiently protected (or remote) from any risk of fire and has its own means of escape

Where are disabled refuges / Type B outstations required? Refuge areas are called for in all non-domestic buildings with more than one storey and they should be provided at each storey exit (i.e. each protected stairway affording egress). Examples of a refuge area include an enclosure such as a protected lobby, corridor or stairway or an area in open air such as a flat roof, balcony, podium or similar place which is sufficiently protected (or remote) from any risk of fire and has its own means of escape.

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

257


SigTel Refuge Alarm System

2-YEAR GUARANTEE

Basic SigTel system wiring with an optical ECU-224 Desk Controller connected

Accessible Toilet Alarm

Green Optional Fire Refuge Telephone Outstation Outstation

2 core 1.5mm2 enhanced 230V fire rated cable

ECU-16 ECU-8 ECU-4 Master Controller

Optional ECU-224 Desk Controller

CAT5 connection lead (supplied with ECU-224)

Network SigTel system wiring with multiple ECU-224 Desk Controllers

ECU-224

ECU-224

ECU-16 ECU-8 ECU-4 230V

230V

ECU-16 ECU-8 ECU-4 230V

Communication Network (only required on network SigTel systems). ECU722 & ECU723 cards mount inside master controllers. Wire the

network in 4 x 2 core 1.5mm2 enhanced fire rated cable. Total network length – 1km. Total no. of networked controllers = 14 (or 224 lines) ECU723 cards are only required if using an optional desk controller. If a desk controller is not required use an ECU722 card instead. Master controllers without handsets (ECU-8NT) are also available but these are not compatible with ECU-224 desk controllers. Product Code

Product Code

Description

4-224 Way Line Controllers R/ECU-4

4 Line SigTEL Master Controller c/w handset. Max 2 x 7Ah batteries

R/ECU-8

8 Line SigTEL Master Controller c/w handset. Max 2 x 7Ah batteries

R/ECU-16

16 Line SigTEL Master Controller c/w handset. Max 2 x 7Ah batteries

R/ECU-8NT

8 Line SigTEL Master Controller (no handset). Max 2 x 7Ah batteries

R/ECU722

Network card, allows up to 14 ECU-4, 8, 16 or 8NTs to be interlinked. (To network a controller that has an optional ECU-224 desk controller fitted use an ECU723 interface/network card instead, see below)

R/CH/EVC302GF

Green handsfree R/CH/EVC outstation, flush mounting

R/CH/EVC302GS

Green handsfree R/CH/EVC outstation, surface mounting

R/CH/EVC302F

Stainless steel handsfree R/CH/EVC outstation, flush mounting

R/CH/EVC302S

Stainless steel handsfree R/CH/EVC outstation, surface mounting

R/CH/BF359/1

IP66 rated enclosure, steel, non-locking (for R/CH/EVC302GF or F)

Disabled Refuge (Type A) Outstations R/CH/EVC301RPO

Red fire telephone outstation, c/w handset (push to open)

R/CH/ EVC385

Grey flush bezel for ECU-4, 8, 16 or 8NT controllers

R/CH/EVC301RLK

Red fire telephone outstation, c/w handset (key lockable)

R/CH/ BF359/2B

Flush mounting bezel for R/CH/F359/2 enclosure

R/CH/T-BEZ301

Red flush bezel for R/CH/EVC301RPO & R/CH/ EVC301RLK

R/CH/ BF359/3M

Flush stainless steel anti-tamper enclosure for ECU-4, 8, 16 or 8NT Medium depth (725W x 448H x 130Dmm)

R/CH/EVC301RPO/SS

Stainless steel fire telephone outstation, c/w handset (push to open)

R/CH/ BF359/3CL

Cam lock kit for R/CH/BF359/3M or R/ CH/BF359/3D

R/CH/T-BEZ301/SS

Stainless steel flush bezel for R/CH/EVC301RPO/ SS

R/CH/ BF359/3SL

Electromagnetic solenoid lock kit for R/CH/ BF359/3M or R/CH/BF359/3D

R/CH/EVC401/PH

Roaming Mk2 red fire telephone handset c/w heavy duty jack plug

R/CH/EVC301/JP

Single gang jack plate for use with R/CH/EVC401/ PH 2

4-224 Way Line Desk Controllers

258

Description

Disabled Refuge (Type B) Outstations

R/CH/ECU224

Optional 1-224 line SigTEL Desk Controller with handset & display. Requires an R/ CH/ECU723 fitted with an R/CH/ECU-4, 8 or 16 Controller. R/CH/ECU-224s are NOT compatible with R/CH/ECU-8NT Controllers

R/CH/ECU723

R/CH/ECU-224 interface/network card. Allows an ECU-224 desk controller to be connected to an R/CH/ECU-4, 8 or 16 Controller. Can also act as a network card if networking is required. NOT compatible with R/CH/ECU-8NT Controllers

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

SigTel Programming Software, Testers, Spares & Accessories

|

R/CH/EVC423/PC

Programming Software, configurator and mini-USB lead

R/CH/ECU-PPT

ECU handset complete with Push-to-Talk button

R/CH/FITT/R/CH/EVC

line tester (saves time on large installations)

R/CH/CATCON

Adaptor box to convert fire-rated cable to Cat 5

R/CH/XSB

Blue xenon strobe, 12V (requires 1 x SDM)

R/CH/SDM

Strobe driver module, 12V

w: deta.co.uk


Refuge Alarm Systems 259

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

259


Door Entry Channel’s vast range of door entry solutions offer audio, video and stand-alone access kits. These kits ensure you have everything you need in one box, simply choose from one of our eight standard kits or contact Channel directly about a custom-made solution to meet your requirements.

260

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Contents Colour Video Door Entry Audio Multiway Door Entry Access Control System

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

264 265 266- 269

|

w: deta.co.uk

261


Kit 3 Proximity Channel also offer bespoke kits that can be made to meet specific customer requirements.

262

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

263


ENTRitech - Video • • • •

GUARANTEE

Simple 2 core cable installation Single power supply supports all monitors and outdoor stations in a flexible combination of up to 32 devices Clear high resolution colour picture on 7” hands free TFT monitor Outdoor station with built in keypad for code door unlocking 2 door release buttons so front/back doors or gates can be opened seperatly 2 outdoor door stations Up to 32 monitor screens Up to 4 monitor screens per apartment (max 32 monitors, i.e 16 apartments with 2 screens, 8 apartments with 4 screens etc.) 2 selectable door/gate release options If you have 2 outdoor units the system only unlocks the appropriate door/gate 2core 0.75mm PVC cable 140m cable run (60m PSU outdoor stations – 80m PSU/last monitor) Simple DIP switch monitor addressing PIN Code entry – Up to 99 separate user codes Surface or flush mounted outdoor station Selectable door control output. Voltage free change over or 12v 300mA DC applied/removed Selectable ‘Lock open’ timer, 6 or 10 seconds

• • •

Easy install

3-YEAR

• • • • • • • • •

7” screen Product Code

Description

D/ENT/VPAN/32/PX

Call panel with keypad & proximity reader. Up to 32 screens – two wire flush mounted

D/ENT/VPAN/32

Call panel with keypad, up to 32 screens. Two wire flush mounted

D/ENT/VM/32

7 inch monitor, White. Two wire

D/ENT/PSU/32

Central power supply adapter (24V, 2.5A) one per system

D/ENT/DIST/32

4-Channel Distributor, For use with apartments with more than one screen

D/ENT/SMB/32

Surface mounting box for outdoor call panel

D/ENT/WH/ED

White exit button

D/ENT/SS/EB

Stainless steel exit button

F/CH/EDR/FLEX

Green emergency door release unit

D/ENT/AUDIO/PSU

Option for door locks Wiring Diagram – 1 screen per apartment Up to 32 screens Locks may be powered by a separate PSU and switched using the changeover relay option

12v Lock 300mA Max 80M Max PVC flex 0.75 Push to exit switch

Push to exit switch 230V AC

60M Mac PVC flex 0.75

264

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Door Entry Systems

ENTRitech™ – Audio • • • • •

Stainless steel call stations Cost effective in installation time and materials Encapsulated electronics / IP44 rated call station Available in flush or surface mounted versions 1 – 18 way systems available to special order

265

The Kit Options... Product Code

Description

Surface Mounted Audio Kits With Embedded Intercom D/ENT/AUDIO/1

1 way audio kit complete with stainless steel 1 button call station, 1 power supply & 1 phone

D/ENT/AUDIO/2

2 way audio kit complete with stainless steel 2 button call station, 1 power supply & 2 phones

D/ENT/AUDIO/3

3 way audio kit complete with stainless steel 3 button call station, 1 power supply & 3 phones

D/ENT/AUDIO/4

4 way audio kit complete with stainless steel 4 button call station, 1 power supply & 4 phones

D/ENT/AUDIO/6

6 way audio kit complete with stainless steel 6 button call station, 1 power supply & 6 phones

D/ENT/AUDIO/8

8 way audio kit complete with stainless steel 8 button call station, 1 power supply & 8 phones

Build Your Own... Product Code

Description

Flush Mounted Audio – Call Station With Embedded Intercom D/ENT/FL/1

Flush master unit with stainless steel 1 module unit complete with embedded intercom (up to 6 way)

D/ENT/FL/2

Flush master unit with stainless steel 2 module unit complete with embedded intercom (up to 12 way)

D/ENT/FL/3

Flush master unit with stainless steel 3 module unit complete with embedded intercom (up to 18 way)

Surface Mounted Audio – Call Station With Embedded Intercom D/ENT/MASTER 1

1 Module stainless steel unit surface mounted complete with embedded intercom (up to 6 way)

D/ENT/MASTER 2

2 Module stainless steel unit surface mounted complete with embedded intercom (up to 12 way)

D/ENT/MASTER 3

3 Module stainless steel unit surface mounted complete with embedded intercom (up to 18 way)

Button Modules D/ENT/AUDIO/KP

Digital keypad module

D/ENT/BU01

1 Button module

D/ENT/AUDIO/1/FL

Flush 1 way audio complete with stainless steel 1 button call station, power supply & 1 phone

D/ENT/BU02

2 Button module

D/ENT/BU03

3 Button module

D/ENT/AUDIO/2/FL

Flush 2 way audio complete with stainless steel 2 button call station, power supply & 2 phones

D/ENT/BU04

4 Button module

D/ENT/BU06

6 Button module

D/ENT/AUDIO/4/FL

Flush 4 way audio complete with 4 button call station, power supply & 4 phones

D/ENT/TMB

Trades men button

S/E60/A

12 Volt relay

D/ENT/AUDIO/6/FL

Flush 6 way audio complete with 6 button call station, power supply & 6 phones

Handset

D/ENT/AUDIO/8/FL

Flush 8 way audio complete with 8 button call station, power supply & 8 phones

D/ENT/AUDIO/HS

Flush Mounted Audio Kits With Embedded Intercom

Audio only handset complete with door release button

Power Supply D/ENT/AUDIO/ PSU

t: 0845 884 7000

Power Supply Unit

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

265


ENTRitech™ – Door Access Control

D/ENT/DA/KP/1 Stainless steel door access keypad

Proximity Reader and

D/ENT/EPX10

Keypad combined

Standalone proximity

D/ENT/KEY/PROX/800

reader

D/ENT/ WH/ED

Door access keypad

D/ENT/SS/EB

• • • • •

D/ENT/STD-PCPS

F/CH/EDR/FLEX

Simple to install Robust construction IP65 Proximity reader option Suitable for up to 21 individual codes Stainless steel keypad option

Specification

266

Access Keypad

(H)137 x (W)93 x (D)55mm

Proximity Reader

(H)116 x (W)75 x (D)22mm

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

D/ENT/KT10-B


Kit 2 – Pin

Kit 3 – Proximity

Access Control Systems

Kit 1 – Pin

267

D/ENT/DA/KIT1 Contains:

D/ENT/DA/KIT2 Contains:

D/ENT/DA/KIT3 Contains:

• • • •

12Vdc 2Amp boxed power supply with battery back up Digital Keypad with up to 21 individual codes Exit button Green break-glass unit Electric lock release

• • • • •

12Vdc 2Amp boxed power supply with battery back up Digital Keypad with up to 21 individual codes Exit button Green break-glass unit Magnetic lock Z&L bracket

• • • • • • •

12Vdc 2 Amp power supply with battery back up Proximity reader (up 2000 users) Exit button Green break glass unit Key fob tokens x 10 pieces Hand held programmer Electric lock release

Kit 4 – Proximity

Kit 5 – Keypad

Kit 6 – Keypad

D/ENT/DA/KIT4 Contains:

D/ENT/DA/KIT5 Contains:

D/ENT/DA/KIT6 Contains:

• • • • • • •

12Vdc 2Amp boxed power supply with battery back up Proximity reader for use with up to 2000 users Exit button Green break-glass unit Key fob tokens x 10 pieces Hand held programmer Magnetic lock Z&L bracket

• • • •

12Vdc 2Amp boxed power supply with battery back up DG180 Keypad Exit button Green break-glass unit Electric Release

t: 0845 884 7000

• • • • •

|

12Vdc 2Amp boxed power supply with battery back up DG180 Keypad Exit button Green break-glass unit Magnetic Lock Z&L bracket

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

267


ENTRitech™ – Door Access Control Kit 7 – Proximity

Kit 8 – Pin & Proximity

D/ENT/DA/KIT8 Contains:

D/ENT/DA/KIT7 Contains: • • • • • •

Product Code

12Vdc 2Amp boxed power supply with battery back up Combined keypad & proximity reader Exit button Green break-glass unit Key fob tokens x 10 pieces Magnetic lock Z & L bracket

Product Code

Description

Description

Accessories

Kits

268

• • • • • • •

12Vdc 2Amp boxed power supply with battery back up Combined keypad & proximity reader Exit button Green break-glass unit Key fob tokens x 10 pieces Electric Release

D/ENT/DA/KP/1

Stainless steel door access keypad

D/ENT/EPX10

Standalone proximity reader

D/ENT/KEY/PROX/800

Stainless steel handsfree R/CH/EVC outstation, flush mounting

D/ENT/KT10-B

Stainless steel handsfree R/CH/EVC outstation, surface mounting

D/ENT/STD-PCPS

IP66 rated enclosure, steel, non-locking (for R/CH/EVC302GF or F)

D/ENT/EPX10-HP

Red fire telephone outstation, c/w handset (push to open)

D/ENT/DA/ KIT1

Key pad door access kit 1: including PSU, digital keypad, exit button, green break glass unit and electric lock release

D/ENT/DA/ KIT2

Key pad door access kit 2: including PSU, digital keypad, exit button, green break glass unit, magnetic lock and Z&L bracket

D/ENT/DA/ KIT3

Proximity reader door access kit 3: including PSU, exit button, green break glass unit, electric lock release, 10 key fobs and a hand held programmer

D/ENT/SS/EB

D/ENT/DA/ KIT4

Proximity reader door access kit 4: including PSU, exit button, green break glass unit, magnetic lock, Z&L bracket,10 key fobs and a hand held programmer

Red fire telephone outstation, c/w handset (key lockable)

D/ENT/WH/ED

Red flush bezel for R/CH/EVC301RPO & R/CH/ EVC301RLK

D/ENT/DA/ KIT5

Key pad door access kit 5: including PSU, keypad, exit button, green break glass unit, Electric release.

D/ENT/RIM

Stainless steel fire telephone outstation, c/w handset (push to open)

D/ENT/MORTICE/FL

Stainless steel flush bezel for R/CH/EVC301RPO/ SS

D/ENT/DA/ KIT6

Key pad door access kit 6: including PSU, keypad, exit button, green break glass unit, magnetic lock and Z&L bracket

D/ENT/PSU

Roaming Mk2 red fire telephone handset c/w heavy duty jack plug

Proximity reader door access kit 7: Combined keypad & proximity reader including PSU, exit button, green break glass unit, magnetic lock and 10 key fobs

F/CH/EDR/FLEX

D/ENT/DA/ KIT7

Single gang jack plate for use with R/CH/ EVC401/PH 2

D/ENT/MAG

Programming Software, configurator and mini-USB lead

D/ENT/MAG/MON

ECU handset complete with Push-to-Talk button

D/ENT/DA/ KIT8

Proximity reader door access kit 8: Combined keypad & proximity reader including PSU, exit button, green break glass unit, electric release and 10 key fobs

D/ENT/MAG/BRACKET

line tester (saves time on large installations)

D/ENT/PSU/12V/2A

Adaptor box to convert fire-rated cable to Cat 5

B/12V/1.2AH/SLA

Blue xenon strobe, 12V (requires 1 x SDM)

D/ENT/AUDIO/PSU

Strobe driver module, 12V

D/ENT/PSU/12V/2A/TD

PSU with time delay

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Door Entry Systems 269

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

269


The Knowledge

270

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Contents Emergency Lighting Specification Help Induction Loop Systems Fire Detection & Fire Alarm Systems

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

272 - 273 274 - 275 276 - 283

|

w: deta.co.uk

271


A Guide To Emergency Lighting

Emergency Lighting – An Overview Lighting makes up approximately 20% of the UK’s energy consumption and non-domestic lighting shamefully accounts for approximately 24 million tonnes of CO2 per annum. As we all know, LED technology is rapidly taking over the lighting business, providing not only an attractive alternative to its conventional counterparts but also proving to provide long term savings in energy and subsequent replacement costs. In addition to energy savings, LEDs in general illumination applications provide longer operating life (in the region of up to 50,000 hours), directionality, compact size, ease of control and dimmability compared to incumbent technologies they replace.

Contractors should be advising about the benefits of LED lighting solutions... The LED has many benefits that should be highlighted to customers during a site survey, such as: Reduced air conditioning costs as LED lights have a lower heat output LED lights last longer than conventional lighting. They create less waste and boast more easily recycled components Cost saving over a longer period of time The LED pros outweigh the cons when it comes to choosing efficient, cost effective lighting solutions for commercial, residential or industrial properties.

System Design Guide The British Standard BS5266 has been revised to conform with the European Standard EN1838 (issued in the UK under reference BS EN1838/BS5266 Part 7) which specifies luminous requirements for emergency systems installed in premises. It also now calls up the luminaire product standard BS EN60598-2-22. An escape lighting luminaire complying with EN 60598-2-22 shall be sited to provide appropriate illuminance near each exit door and at positions where it is necessary to emphasise potential danger or safety equipment. The positions to be emphasised shall include the following:

System Design Guide Continued...

Exit Signage Requirements

• At each exit door intended to be used in an emergency • Near stairs so that each flight of stairs receives direct light Near any other change in level • Mandatory emergency exits and safety signs • At each change of direction • At each intersection of corridors • Outside and near to each final exit • Near first Aid Post • Near fire fighting equipment • Near escape equipment for the disabled • Near disabled refuge and call points

• Safety signs shall be illuminated to at least 50% of the required luminance within 5 seconds and full required luminance within 60 seconds. • The colours shall conform to the requirements of ISO 3864. • The luminance of any area of safety colour of the sign shall be at least 2 cd/m2 in all relevant viewing directions. • The ratio of the maximum to the minimum luminance within either white or the safety colour shall be not greater than 10:1. • All signs must be of the same type within a building and not mixed

272

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

For further information review the Technical Statement published by ICEL (ICEL TS03 Issue 1 – 12/12) on Emergency Exit “Clear” Signs.

w: deta.co.uk


Emergency Escape Lighting To provide visibility for evacuation purposes lighting is required in the volume of the space. In this standard the recommendation is filled by the mounting of luminaires at least 2m above the floor. Signs which are provided at all exits intended to be used in an emergency and along escape routes shall be illuminated to indicate unambiguously the route of escape to a point of safety. Where direct sight of an emergency exit is not possible, an illuminated directional sign (or series of signs) shall be provided to assist progression towards the emergency exit. An escape lighting luminaire complying with EN 6059-2-22 shall be sited to provide appropriate illuminance near each exit door and at positions where it is necessary to emphasise potential danger or safety equipment. The positions to be emphasised shall include the following (see opposite page):

273

Emergency Route Lighting • For escape routes up to 2m in width, the horizontal illuminances on the floor along the centre line of an escape route shall be not less than 1 Ix and the central band consisting of not less than half of the width of the route shall be illuminated to a minimum of 50% of that value.

Open Area (Anti-Panic) Lighting

• At each exit door intended to be used in an emergency • Near stairs so that each flight of stairs receives direct light • Near any other change in level • Mandatory emergency exits and safety signs • At each change of direction • At each intersection of corridors

At each door

• Outside and near to each final exit • High risk task areas Various specific locations now require additional emergency illumination: 5 Lux – Refuge Areas, Panic Bars, Swimming Pool Areas 15 Lux – Kitchens, First Aid Rooms, Plant Rooms, Fire Alarm Control Equipment, Reception 50 Lux - Treatment Rooms

Emergency Lighting Specifications Help

Help & Assistance When Specifying Emergency Lighting

• The horizontal illuminance shall be not less than 0.5 Ix at the floor level of the empty core area which excludes a border of 0.5 m of the perimeter of the area. • High risk task areas

Near any changes of direction

Near each intersection

On each staircase so that all

To illuminate all exit and safety

Near each fire alarm call point

treads and risers receive

signs and first aid points

Outside each final exit and near any obstructions

At each change of floor level

direct light

Near fire fighting equipment

In toilets with a total floor area

Inside disabled toilets

Near lift cars and inside

of 8m2 or more / with no natural light

Escalators and

Control and plant rooms and

moving walkways

electrical cupboards

Room with no natural lights

A minimum of two fittings per fire compartment

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

273


Guide To Disability System Design Disability and the Equality Act 2010

System Design Guidance

From 1 October 2010, the Equality Act has combined all previous acts relating to discrimination, into one, more encompassing legal area.

Always refer to the requirements of the Building Regulations 1991, and the Building Regulations (Amendment) 1998, Part M (Access and facilities for disabled people) so as to practice good building design.

This means that although the Disability Discrimination Act (DDA) has been superseded by the Equality Act, the Disability Equality Duty in the DDA continues to apply.

Equality Act 2010 The Equality Act 2010 aims to protect disabled people and prevent disability discrimination. It provides legal rights for disabled people in the areas of: • Employment • Education • Access to goods, services and facilities including larger private clubs and land based transport services buying and renting land or property • Functions of public bodies, for example the issuing of licences The Equality Act also provides rights for people not to be directly discriminated against or harassed because they have an association with a disabled person. This can apply to a carer or parent of a disabled person. In addition, people must not be directly discriminated against or harassed because they are wrongly perceived to be disabled.

Under the Equality Act 2010, a person has a disability if: • they have a physical or mental impairment • the impairment has a substantial and long-term adverse effect on their ability to perform normal day-to-day activities For the purposes of the Act, these words have the following meanings: • ‘substantial’ means more than minor or trivial • ‘long-term’ means that the effect of the impairment has lasted or is likely to last for at least twelve months (there are special rules covering recurring or fluctuating conditions) • ‘normal day-to-day activities’ include everyday things like eating, washing, walking and going shopping People who have had a disability in the past that meets this definition are also protected by the Act. Progressive conditions considered a disability – There are additional provisions relating to people with progressive conditions. People with HIV, cancer or multiple sclerosis are protected by the Act from the point of diagnosis. People with some visual impairments are automatically deemed to be disabled. Conditions that are specifically excluded – Some conditions are specifically excluded from being covered by the disability definition, such as a tendency to set fires or addictions to non–prescribed substances.

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

There are numerous methods of compliance with the Disability Discrimination Act including fixed equipment such as visual alarm indicators, portable equipment such as vibrating pagers and pillows or instructing staff to ensure the safety of disabled persons using the premises. • Failure to provide fire alarm protection for disabled persons in any business premises is a breach of the law. • All automatic door opening installations must comply to BS7036. • On any door opening installation please be aware finger guards may be required either roller blind type or finger guard (plastic).

Penalties for failing to comply The DDA gives disabled people the right to bring a civil claim against your business where they find you have breached the provisions of the DDA and discriminated against them. If in doubt contact our technical team on 0845 884 7000.

Types of Disability

The definition of ‘disability’

274

All business must now provide facilities for disabled persons and this legal obligation extends to the fire alarm system.

|

A typical perception of a disabled person is that they are wheelchair users, however this is a huge misconception. The split of disability according to the latest available figures in the UK is as follows: • Hearing Impairment 51% • Mobility Problems 22% • Wheelchair users 3% • Blind / partially sighted 15% • Speech impediments 4% • Other 5%

Who is affected by the Disability & Equality Act • Does your organisation provide goods or services to the public? • Do members of the general public visit your premises? • Does your organisation conduct interviews on your premises? • Do you carry out training/instruction in your premises? • Does your organisation have a WEB site? • Are you a landlord?

Useful Contacts... Equality Advisory Support Service Phone: 0808 800 0082 Textphone: 0808 800 0084 Website: www.equalityadvisoryservice.com

w: deta.co.uk


Disability and the Equality Act 2010 Hearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a ‘T’ or ‘MT’ switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its user’s specific hearing requirements. Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position, allowing them to participate more effectively in general conversation, ordering goods or services, listening to public performances, etc. A hearing loop system therefore comprises the following main elements: 4 The audio source – typically a microphone, television or other audio input (sometimes more than one). 4 The hearing loop amplifier 4 The loop – typically one or two turns of wire usually run around the perimeter of the room or a special counter loop fixed to the underside of a table or desk. 4 The receiver(s) – any hearing aid with a ‘T’ or ‘MT’ switch or a specially designed loop listening device. In addition to the many routine benefits for hearing aid users, hearing loop systems can also be used for other limited area broadcasting applications such as museum ‘walk through’ guided tours and surveillance talkback systems.

The main elements of an induction loop system

Why We Have Induction Loop Systems In normal use, hearing aids utilise a microphone that can amplify localised speech from a distance of up to 2m away. Whilst this is effective for local conversations/quiet environments, it is less effective for listening to speech or music at a distance or in front of a security screen at a ticket counter. This is because the hearing aid’s microphone also picks up any background noise in the room and unwanted speech from other conversations. A hearing loop system works by moving the required sound closer to the hearing aid via the hearing aid’s telecoil which is activated by turning it to the ‘T’ or ‘MT’ position. As telecoils are fitted as standard to most hearing aids (over 90% are said to have the ‘T’ position) hearing loop systems can be considered cost-effective compared to other hearing assistance systems. Infrared systems, for example, require special receivers, the cost and maintenance of which must be met by the service provider. Many modern hearing aids do not just amplify all frequencies equally; they are tailored to suit the user’s hearing requirements and amplify different bands by different amounts. This gives maximum intelligibility, so the user has the best chance of understanding what is said.

275

Which induction Loop System should I use? The Channel safety range of hearing loop equipment comprises a huge range of amplifiers, microphones, connector plates, loop cable and test equipment covering every conceivable AFILS application. Designed to meet or exceed the requirements of BS 7594 and EN60118-4,our amplifiers offer excellent intelligibility, true current mode amplification,‘ phantom’ power (for use with electret microphones) and full compatibility with our Outreach plate audio input extension system. Much of our equipment is available in kit format for ease of use, specification, purchase and installation.

Audio Source

Induction loop Amplifier

Induction Loop Systems

Guide To Selecting Your Induction Loop System

Hearing Aid

Audio Source

Please contact us for assistance in designing the system to suit your requirements.

The Loop

Some hearing loop systems may require additional audio sources such as multiple microphone or line level inputs. To facilitate this, many PDA range amplifiers include a patented ‘Outreach’ socket which allows the connection of multiple inputs via a range of specially designed single gang audio connector plates.

How Does An Induction Loop System Work? Hearing loop systems do not use radio frequencies; they operate at audio frequencies. The signal from an audio source is fed into a hearing loop amplifier, which amplifies and sets the signal level in the same way as a conventional amplifier. The amplified signal, instead of going to a loudspeaker, is fed to a closed loop of cable that is normally placed around the perimeter of the room (although other, more sophisticated ‘loop patterns’ can be employed). Using a constant current amplifier ensures the current is maintained at the set level whilst providing a flat frequency response without the need for equalisation circuitry. The current flowing through the loop generates a magnetic field that radiates in the space around the loop cable. Any lines of magnetic flux that pass through the telecoil in a receiver, such as a hearing aid, will generate a current in the coil that is then converted back to audio and fed into the listener’s ear. It is important to remember that the magnetic field will ‘bleed’ outside the perimeter of the loop and therefore a loop system cannot be considered confidential.

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

275


A Guide to BS5839-1-Fire Detection and Fire Alarm Systems in Non-Domestic Premises The Regulatory Reform (Fire Safety Order (FSO) Became Law On 1 October 2006 Legally You Must Comply! What Is The Fso? Fire authorities no longer issue fire certificates and those previously in force now have no legal status. The Regulatory Reform (Fire Safety) Order (FSO) replaced most fire safety legislation with one new Order. It means that any person who has some level of control in premises (normally the employer) must take steps to reduce the risk from fire, consider how to contain a fire should one break out and then also make sure people can safely escape if there is a fire. • All fire alarm designs should be based on an assessment of the risk • All Fire Risk Assessments should be carried out by a competent person • Fire Risk assessments must be reviewed regularly

Designer Responsibilities

What Constitutes A Fire Risk Assessment And Its Outcome? • Identifying fire hazards such as sources of ignition, fuel or oxygen • Identifying all people at risk in and around the premises • Evaluating the risk of a fire starting and the risk to people from a fire • Removing or reducing fire hazards or risks to people from a fire • Protecting people by providing fire precautions • Recording the significant findings • Preparing an emergency plan • Informing and instructing any relevant people, including visitors • Providing training for staff • Reviewing the fire risk assessment regularly and make changes where necessary • Keeping accurate fire risk assessment records

Where Does The Order Apply? Virtually all premises and nearly every type of building structure and certain open spaces. If you would like to find out more about how Apollo products can help you comply with the FSO please contact us on 023 9249 2412 or visit our website on www.apollo-fire.co.uk

276

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

This Guide is Intended To Be An Aid To Designers & Installers of Fire Detection Systems. It is Not To Be Used As A Substitute For BS 5839-1 Which Should be Read In Full. In Order To Help Identify The Relevant Sections, Each Diagram Includes A Reference To BS 5839-1

|

NOTES: (1) BS 5839-1 recommends that a fire detection system is designed by a competent person, who takes responsibility for completing the design and signing off a ‘Design certificate’. This should not be confused with other certificates relating to Installation. (2) If the contract allows, it is suggested that the Designer witnesses testing of the completed system to ensure the original design is still appropriate; the Design certificate can then be completed after any amendments are included. The following recommendations should be followed when designing a fire detection system: • Establish the level of fire protection suitable to the premises type in agreement with the owner/occupier and relevant interested parties • Document any reasons to justify variation of design • Identify detection and alarm zones • Raise specification document and building plan to show location of: - All manual call points - All types of detector - All sounders and visual alarms - Any other items of detection • Cable specification for each circuit • State the System and equipment to be used • Details of other equipment that may be linked into the system to be specified • Measures incorporated to limit false alarms • Provide a fire plan or cause and effect chart • Design certificate signed

w: deta.co.uk


Property Protection Fire Systems P - AFD designed primarily to protect property P1 - AFD installed throughout all areas P2- AFD installed only in defined areas

Detection Zones A detection zone should cover no more than 1 storey, unless total floor area is less than 300m2. Voids in the same fire compartment should be included in the same floor zone. The maximum floor area of a zone should not be greater than 2,000m2, except for some large open plan areas that incorporate manual call points only, which can be extended to 10,000m2. The maximum search distance for the fire fighters to see the seat of the fire within a zone should not exceed 60m assuming the route taken is the worst possible option. Vertical structures like stairwells, lift shafts etc., should be considered as separate zones.

Fire Detection & Fire Alarm Systems

Fire Alarm & Detection Systems Are Categorised In The Following Way:

277

A manual call point within a staircase should be connected to the zone associated with that floor and ideally be mounted on the accommodation side of the corridor exit. Automatic sensors on the stairwell remain as part of the stairwell detection zone.

P1

P2

Property Protection Fire Systems

L4 L3

L2

L2

Zone 4

L AFD designed to primarily protect Human Life L1 AFD installed throughout all areas L2 AFD installed in defined areas in addition to L3 L3 AFD installed in escape routes and rooms or areas opening onto these routes L4 AFD installed in escape routes comprising circulation area and spaces such as corridors and stairways L5 A non-prescriptive system in which protected area(s) and/or the location of detectors is designed to satisfy a specific fire risk objective (other than that of L1 to L4) M System design to be operated manually (no AFD) *AFD Automatic Fire Detection

Zone 3 Zone 5 Zone 2 Zone 1

Alarm Zones An alarm zone is clearly defined within the standard but generally is an area of the building coinciding with the fire compartment boundaries. There must be a clear break between these alarm zones to ensure alert and evacuation messages are not overheard from adjacent areas. The only other criteria is that an alarm zone may consist of a number of detection zones but not vice versa. Alarm zones are required when phased or staged evacuation is required. It is therefore important that care should be taken to ensure only one message is heard at any one time particularly where two alarm zones are attached.

Zone 10

Detection Zone 11

Detection Zone 12

Alarm Zone 3

Detection Zone 7

Detection Zone 8

Detection Zone 9

Alarm Zone 2

Detection Zone 4

Detection Zone 5

Detection Zone 6

Alarm Zone 1

Detection Zone 1

Detection Zone 2

Detection Zone 3

Alarm Zone 4

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

277


Section 2 Clause 13.2.3

Clause 22.3 Smoke Detectors 7.5m

60m MAX

10.6m x 10.6m = 112m2 5.3m 10.6m

A person searching a zone for a fire in a non-addressable fire system should not have to travel more than 60m to identify the source of a fire.

Clause 22.3

When mounted on a flat ceiling, smoke detection devices have an individual coverage of 7.5m radius. However these radii must overlap to ensure there are no ‘blind spots’. Therefore individual coverage can be represented by a square measuring 10.6m x 10.6m giving an actual area coverage of 112m2 per device.

Heat Detectors

<25mm X

5.3m

>600mm X 7.5m x 7.5m = 56.3m2

Optical chamber

Smoke detector

3.8m

The sensing element of a smoke detection device (optical smoke or ionisation chamber) should not be less than 25mm below ceiling, and not greater than 600mm below ceiling.

<25mm X

7.5m

When mounted on a flat ceiling, heat detection devices have an individual coverage of 5.3m radius. However these radii must overlap to ensure there are no ‘blind spots’. Therefore individual coverage can be represented by a square measuring 7.5m x 7.5m giving an actual area coverage of 56.3m2 per device. Treat as a flat ceiling

Ceiling with an apex

Apex <150mm Apex <600mm

Apex >150mm Apex >600mm

>150mm X Thermister Heat detector

Heat Detector Smoke Detector Heat Detector Smoke Detector

The sensing element of a heat detection device should not be less than 25mm below ceiling, and not greater than 150mm below ceiling.

Clause 35.2.3

For ceilings that feature an apex: as long as the height of the apex from the rest of the ceiling is less than 150mm for heat detectors or less than 600mm for smoke detectors, then these can be treated the same as flat ceilings. For higher apexes, a device should be installed at the highest point. The distance to adjacent devices can be increased by 1% per degree of angle of the roof up to a maximum of 25%. Response

Temperature

Max Height 100 90 80 70 60 50 40 30 20 10

<29°C

<4°C

X

X

Maximum temperature

Average ambient temperature Time of day

The minimum static response to heat devices should not be less than 29°C above the average ambient temperature, or less than 4°C above the highest temperature the device can expect to experience. 278

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

All categories of system

Detector Type

General Area

10% of Area

Heat RoR

9m

10.5m

Heat Fixed

7.5m

10.5m

Smoke/CO Point

10.5m

12.5m

Optical Beam Normal Sensitivity

25m

28m

Optical Beam Enhanced Sensitivity

40m*

43m*

ASD General Limit

10.5m

12.5m

ASD Class C with at least 5 holes

15m

18m

ASD Class C with at least 15 holes

25m

28m

ASD Class B with at least 15 holes

40m†

43m†

* Supplemented detection recommended unless risk of stratification is minimal. † Multi-level detection recommended unless risk of stratification is minimal.

w: deta.co.uk


Fire Detection & Fire Alarm Systems

Smoke Detectors 7.5m

7.5m

7.5m >800mm

2m 15m

15m

In corridors less than 2m wide the horizontal spacing of detectors may be increased, the areas of coverage need not overlap as in the case of a room. Any corridor over 2m wide is deemed a room and device spacing should follow the standard for rooms (see page 140).

<1m

In corridors less than 2m wide the horizontal spacing of detectors may be increased, the areas of coverage need not overlap as in the case of a room. Any corridor over 2m wide is deemed a room and device spacing should follow the standard for rooms (see page 140).

Lift Shaft

279

Lift Shaft

>1m 1.5m

Air Vent/Air Con

X

<300mm

X

<500mm

>10% Ceiling Height

X

Partition

<500mm

Beam

Do not site detectors less than 1m from air supply points or air circulating units.

Vertical shafts like lifts and open stairways should have a device mounted within 1.5m of any opening. (This is not necessary for enclosed stairways, because as noted below, there are detectors on every landing within the stairway).

A device should not be mounted within 500mm of any obstruction. If the top of a solid partition is less than 300mm from ceiling then treat it as a wall. Similarly, ceiling obstructions such as beams should be treated as walls if deeper than 10% of the ceiling height.

Enclosed stairways should have a detector at the top of the stairway and on each main landing.

Clause 20.2

D X

<2D

Route to travel 30m max. (undefined) at design stage

250mm (Max)

Light Fitting/ Obstruction

Never mount devices closer than twice the depth of light fittings or other obstructions on the ceiling.

Route to travel 45m max. (defined) at design stage A person should not have to travel more than 45m to reach a Manual Call Point, for a defined escape route (25m if significant proportion of occupants have limited mobility or rapid fire development is likely). For an undefined route a person should not have to travel more than 30m to reach a Manual Call Point (16m if significant proportion of occupants have limited mobility or rapid fire development is likely).

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

279


–30dB(A)

1.4m (+/–300mm)

The centre of the element of the manual call point should be positioned 1.4m (+/-300mm) from floor level. Unless a wheelchair user is likely to be the first person to raise the alarm. (Between 800-1200mm according to Doc. M. + Equality Act). BS 5839 states transparent hinged covers should be fitted to all manual call points.

FIRE DOOR

NORMAL DOOR

–20dB(A)

Clause 17

Clause 16.2.1 No measurements needed within 500mm of boundary 65 (blue area)

60

2.5m (X) 65

60 Enclosure of less than 60m2 . minimum of 60 60dB(A)

65

7m (y)

7m (y)

Areas of less than 1m2 habitable space. No minimum

The coverage volume code is presented as W-x-y. If the wall mounted Visual Alarm Device (VAD) is installed at the height of 2.5m from floor level, and the coverage is 7m x 7m square, then it would be referred to as W-2.5-7.

60

The minimum sound level should be 65dB(A) or 5dB(A) above a background noise which is louder than 60dB(A) (if lasting more than 30 seconds) and at a frequency of between 500Hz and 1000Hz. The maximum sound level should not be greater than 120dB(A) at any normally accessible point. May be reduced to 60dB(A) in stairways, enclosures up to 60m2 and specific points of limited extent.

3m (x) y/1.414 8.5m (y) The coverage volume code is presented as C-x-y. If the ceiling mounted Visual Alarm Device (VAD) is installed at the height of 3m from floor level, and the coverage diameter is 8.5m, then it would be referred to as C-3-8.5.

Sounder device cabling should be arranged so that in the event of a fault at least one sounder will remain operational during a fire condition.

Clause 26 Built in End-of-Line

DOOR

75dB(A)

Mains supply For areas where people are sleeping, sounder devices should produce a minimum 75dB(A) at the bed-head with all doors shut. In buildings providing sleeping accommodation for deaf or people with impaired hearing, bedrooms should have both audible and visual alarms. (Note: Visual Alarm Devices are not intended to wake sleeping persons). 280

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

Fire resistant cabling is now required within the whole fire alarm system including the mains supply cables. The use of non-fire resisting cables whether mechanically protected by fire-resisting construction or not, will no longer comply with BS 5839-1.

|

w: deta.co.uk


• If an insulation resistance test is carried out, ensure that the field devices are disconnected. Make sure that the loop cables are grounded before field devices are reconnected. • Once a detector has been fitted, ensure that the dust cap stays on until the system has been commissioned and the environment is clean.

Documentation Short circuit isolators limit the effect of one fault to 2000m2 and to a single storey of the building. ‘2 simultaneous faults on a circuit should not disable protection within an area greater than 10,000m2’.

Clause 12.2.2 • Suitable means of local safe isolation of the low voltage supply circuit for the power supply and control equipment must be provided (see Section 2 Clause 25.2c & f) • All cables to be fire resistant with a minimum cross-sectional area of 1mm² (see Section 2 Clause 26.2j) • All joints ‘other than those within the system components’ to be fire resistant. Junction boxes to be labelled ‘FIRE ALARM’ (see Section 2 Clause 26.2g) • Enhanced cable to be used where more than 4 zones of phased evacuation required, in multi storey systems, hospitals (un-sprinklered over 30m) or risk assessment requires enhanced cable (see Section 2 Clause 26.2c) • Cable using trunking as a means of containment must be clipped using fire resistant supports WITHIN THE TRUNKING (see Section 2 Clause 26.2h) • Fire Alarm control panel(s) are installed at a location appropriate for staff and firefighters (see Section 2 Clause 23.2) • Manual call points are required at all exits to the open air – whether or not the exits are specifically designed to be fire exits unless, for example, the exits lead to an enclosed courtyard from which there is no escape (see Section 2 Clause 20.2c). • CO fire detectors should be spaced as per smoke detectors, but cannot be used without smoke detectors on escape routes (see Section 2 Clause 22.4) • Multi-sensors, incorporating smoke detection should be spaced as smoke detectors, if used as individual types, for example heat in the day & smoke at night then detectors are spaced in this case as per heat detectors (see Section 2 Clause 21.1.6) • Linear heat detection cable should be spaced as a point heat detector (see Section 2 Clause 22.3) • Unusual ceilings: Cellular ceiling, perforated ceilings or ceilings with closely spaced beams have special spacing & installation requirements (see Section 2 Clause 22.3 including Tables 1 & 2) • Bells & Electronic sounders cannot be mixed (see Section 2 Clause 16.2.1c) • Sound levels can be reduced to 60dB(A) in stairs, small cellular rooms or enclosures of no more than APPROXIMATELY 60m2. Bedhead levels remains 75dB(A) (see Section 2 Clause 16.2.1a) • Where applicable, all areas of the building have been fitted with Sounders and Visual Alarm/Tactile Devices in areas of high ambient noise, or where deaf people or people with impaired hearing may be alone or isolated from others i.e. bedrooms and sanitary facilities (see Sections 2 Clause 17 & 18) • A minimum of one sounder is required in each fire compartment (see Section 2 Clause 16.2.1i) • Full documentation required, test results as fitted drawings etc. (see Section 5 Clause 40) • An installation certificate will be required (Section 5 Clause 41.2) • Ensure that the installation wiring complies with the BS 58391 requirements and the latest edition of the IET Electrical Regulations

On completion of commissioning and user training all documentation will have to be collected and handed to the client or their representative. This will include: • Design, Installation and Commissioning certificates. • Cable and insulation resistance test records. • “As fitted” drawings of the final installation, including cable run details • Product manuals and user instructions System log book. • A copy of the fire plan documentation against which the commissioning engineer programmed the system • The designer’s specification and a written list of agreed Variations

Fire Detection & Fire Alarm Systems

Clause 12.2.2

281

Installation and handover checklist 1. The system complies with the original specification / design 2. Any changes to original specification/design have been referred to the system designer for approval 3. System has been installed to meet recommendations of category L1, L2, L3, L4, L5, P1, P2, M 4. Variations to the defined category have been identified and the schedule of variations agreed with the client 5. Cables meet requirements for standard/ enhanced/mixed 6. Cables are segregated as required and suitably supported (no plastic clips, cable ties or trunking used as sole means of support) 7. Cables are mechanically protected as required 8. Junction boxes are correctly labelled and identified on drawings. Connector blocks are fire resistant 9. All cable insulation and continuity resistance measurements are logged 10. All cable penetrations are sleeved and fire stopped 11. Mains supply is dedicated, non-switched, correctly fused and labelled 12. Mains supply is correctly identified at all distribution boards 13. Standby battery verification has been carried outfor all power supplies

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk

281


14. All batteries are clearly marked and labelled with date of installation 15. Field wiring is labelled and correctly terminated in all control and ancillary equipment 16. Isolators are fitted as appropriate, operate correctly and are marked on drawings 17. There are a minimum of two sounder circuits installed 18. Sound pressure levels have been checked and recorded and meet the minimum requirements 19. Detector type and spacing is appropriate to the system category 20. MCPs are located correctly and travel distance is appropriate to the system category 21. Remote signalling has been checked for correct operation to Alarm Receiving Centre 22. Zone plans have been fitted in all appropriate locations (adjacent to control equipment and repeaters) this must be a plan, a list does not suffice 23. As fitted drawings are complete and have been updated where required, including cable size and routing 24. Log book and operating instructions have been issued to the responsible person 25. The premises management have been adequately trained in the use of the fire alarm system

282

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Fire Detection & Fire Alarm Systems

A Guide To Building Regulations, IP Ratings & Kelvin Light Scale Building Regulations To ensure specified luminairs meet the requirements of the current building regulations it is important to consider the legislation contained within the Building Regulations. The most relevant of these are:

283

Approved Document B • Approved Document B (Fire safety) – Volume 1: Dwellinghouses (2006 Edition) • Approved Document B – Volume 2: Buildings other than dwellinghouses (2006 Edition) Part B deals with the fire safety requirements for emergency lights and the use of thermoplastic materials.

• Approved Document L2B: Conservation of fuel and power (Existing buildings other than dwellings) (2006 Edition) Part L requires that energy efficient lighting is installed in both domestic and nondomestic dwellings, existing, new & refurbished (over 100m2) Part L gives design information for the following (non-domestic dwellings). • Selection of lamp types • Effective use of daylight • Control gear & power factor correction • Use of lighting controls • Luminaire efficiency

Approved Document L • Approved Document L 1A: Conservation of fuel and power (New Dwellings) (2006 Edition) • Approved Document L 1 B: Conservation of fuel and power (Existing Dwellings) (2006 Edition) • Approved Document L2A: Conservation of fuel and power (New buildings other than dwellings) (2006 Edition)

It is our recommendation that reference be made to the latest version of the Approved Documents. Full details can be found on: www.planningportal.gov.uk

IP Ratings

The International Protection code, commonly known as the Ingress Protection code (IP) indicates the protection afforded by an enclosure against the ingress of foreign (solid) bodies and ingress of moisture and liquids. The IP rating also classifies the protection given by an enclosure against touching live or moving parts. The IP rating is given by the use of two numbers

First Digit

Second Digit

0

No protection

0

No protection

1

Protection against large sized bodies such as hands

1

Protection against vertically falling drops of water

2

Protection against medium sized bodies such as fingers

2

Protection against drops of water up to 15° from the vertical

3

Protection against small sized bodies 2.5mm dia. or larger such as tools & wires

3

Protection against rain falling up to 60° from the vertical

4

Protection against very small sized bodies 1 mm dia. or greater

4

Protection against splashed water from any angle

5

Protection against harmful deposits of dust. (Dust proof)

5

Protection against jets of water from any angle

6

Complete protection against deposits of dust. (Dust tight)

6

Protection against water from heavy seas

7

Protection against immersion for a defined period

8

Protection against immersion for an indefinite period

Candlelight

Electoronic Flash

Tungsten Light Early Sunrise

Noon Daylight

Overcast Daylight

Household Light Bulb

1,000k

2,000k

3,000k

4,000k

5,000k

6,000k

t: 0845 884 7000

7,000k

|

8,000k

9,000k

e: sales.lfs@deta.co.uk

|

10,000k

w: deta.co.uk

283


Index Catalogue Code Page No. 1000/2/B 82 10000/1PH 83 10000/3PH 83 1500/2/B 82 3300/2/B 82 5000/3/B 82 B/1.2V/4AH/NICD 181 B/12V/0.8AH/SLA 180 B/12V/1.2AH/SLA 180 B/12V/1.2AH/SLA 268 B/12V/12AH/SLA 180 B/12V/12AH/SLA 225 B/12V/17AH/SLA 180 B/12V/2.1AH/SLA 180 B/12V/2.1AH/SLA 233 B/12V/2.3AH/SLA 180 B/12V/2.3AH/SLA 233 B/12V/2.3AH/SLA 253 B/12V/2.8AH/SLA 180 B/12V/2.8AH/SLA 233 B/12V/24AH/SLA 180 B/12V/3.2AH/SLA 180 B/12V/3.2AH/SLA 194 B/12V/3.2AH/SLA 195 B/12V/3.2AH/SLA 200 B/12V/3.2AH/SLA 202 B/12V/3.2AH/SLA 206 B/12V/4AH/SLA 180 B/12V/7AH/SLA 180 B/12V/7AH/SLA 197 B/12V/7AH/SLA 206 B/12V/7AH/SLA 221 B/12V/7AH/SLA 225 B/12V/7AH/SLA 233 B/12V/7AH/SLA 250 B/12V7AH/SLA 249 B/2.4V/4AH/NICD 181 B/2.4V/4AH/ 181 B/3.6V/4AH/NICD 181 B/3.6V/4AH/ 181 B/4.8V/4AH/NICD 181 B/4.8V/4AH/ 181 B/6V/4AH/NICD 181 B/6V/4AH/NICD/S 181 B/BATT/ALPINE 130 B/BATT/BROOK/2 124 B/BATT/CAMBER 136 B/BATT/DA/FO/ 137 B/BATT/DA/FO/ 137 B/BATT/GROVE/3 140 B/BATT/GROVE/3 140 B/BATT/METEOR/ 122 B/BATT/MM 123 B/BATT/RAZOR/ 133 B/BATT/RAZOR/W 133 B/BATT/SOL 125 B2010 106 B2015 106 B2020 106 B2025 106 BI2112 93 BI2113 90 BI2121 93 BI3112 74 BI3112E 74 BI4112 72 BI4112E 72 BI4112P 73 BI4112PE 73 BI4114 72 BI4114E 72 BI4114P 73 BI4114PE 73 BI4115 72 BI4115E 72

284

0845 884 t:t:01582 5447000 544

||

Catalogue Code BI4115P BI4115PE BI6111 BI6121 BR1111 BR1112 BR1113 BR1121 BR1122 BR1123 BR1191 BR1193 BR1194 BR1195 BR1196 BR1251 BR1252 BR1253 BR1254 BR3001 BR3010 BR3020 BR3030 BR3050 BR3101 BR3102 BR3103 BR3104 BR3105 BR3121 BR3122 BR3123 BR3124 BR3125 BR3501 BR3502 BR3511 BR3512 BR3513 BR3514 BR3521 BR3522 BR3523 BR3524 BR4112 BR4112E BR4114 BR4114E BR4114T BR4114TE BR4115 BR4115E BR4115T BR4115TE BR4116 BR4116E BR4116T BR4116TE BR4251 BR4252 BR4253 BR4254 BR4255 BR4256 BR4257 BR4258 BR4259 BR4260 BR4261 BR4262 BR5114 BR5114E BR5114T BR5114TE BR5115

Page No. 73 73 111 111 34 34 35 34 34 35 34 34 34 34 35 36 36 36 36 22 22 22 22 22 17 17 17 17 17 18 18 18 18 18 30 30 31 31 31 31 31 31 31 31 42 43 42 43 42 43 42 43 42 43 42 43 42 43 40 41 40 41 40 41 40 41 40 41 40 41 60 61 60 61 60

e: sales@deta.co.uk sales.lfs@deta.co.uk| e:

Catalogue Code Page No. BR5115E 61 BR5115T 60 BR5115TE 61 BR5116 60 BR5116E 61 BR5116T 60 BR5116TE 61 BR5194 63 BR5410 62 BR5412 62 BR5414 62 BR5415 62 BR5416 62 BR6111 50 BR6111E 50 BR6111EM 50 BR6111M 50 BR6195C 50 BTHB2A 27 BTHB3A 27 BTHB5A 27 BTHB9A 27 C/STI-LED-200 176 C/STI-LED-400 176 C/STI-LED-COR 176 D/ENT/AUDIO/1 265 D/ENT/AUDIO/1/ 265 D/ENT/AUDIO/2 265 D/ENT/AUDIO/2/ 265 D/ENT/AUDIO/3 265 D/ENT/AUDIO/4 265 D/ENT/AUDIO/4/ 265 D/ENT/AUDIO/6 265 D/ENT/AUDIO/6/ 265 D/ENT/AUDIO/8 265 D/ENT/AUDIO/8/ 265 D/ENT/AUDIO/HS 265 D/ENT/AUDIO/KP 265 D/ENT/AUDIO/ 264 D/ENT/AUDIO/ 265 D/ENT/AUDIO/ 268 D/ENT/BU01 265 D/ENT/BU02 265 D/ENT/BU03 265 D/ENT/BU04 265 D/ENT/BU06 265 D/ENT/DA/KIT1 268 D/ENT/DA/KIT2 268 D/ENT/DA/KIT3 268 D/ENT/DA/KIT4 268 D/ENT/DA/KIT5 268 D/ENT/DA/KIT6 268 D/ENT/DA/KIT7 268 D/ENT/DA/KIT8 268 D/ENT/DA/KP/1 268 D/ENT/DIST/32 264 D/ENT/EPX10 268 D/ENT/EPX10-HP 268 D/ENT/FL/1 265 D/ENT/FL/2 265 D/ENT/FL/3 265 D/ENT/KEY/ 268 D/ENT/KT10-B 268 D/ENT/MAG 268 D/ENT/MAG/ 268 D/ENT/MAG/ 268 D/ENT/MASTER 1 265 D/ENT/MASTER 2 265 D/ENT/MASTER 3 265 D/ENT/MOR268 D/ENT/PSU 268 D/ENT/ 268 D/ENT/ 268 D/ENT/PSU/32 264 D/ENT/RIM 268

|w: deta.co.uk w: deta.co.uk

Catalogue Code Page No. D/ENT/SMB/32 264 D/ENT/SS/EB 264 D/ENT/SS/EB 268 D/ENT/STD-PCPS 268 D/ENT/TMB 265 D/ENT/VM/32 264 D/ENT/VPAN/32 264 D/ENT/VPAN/32/ 264 D/ENT/WH/ED 264 D/ENT/WH/ED 268 E/5IN1 134 E/AL/LEG/LARGE/ 131 E/AL/LEG/LARGE/ 131 E/AL/LEG/LARGE/ 131 E/AL/LEG/LARGE/ 131 E/AL/M3/LED 130 E/AL/M3/SL/RC 130 E/ALPINE/LARGE 131 E/AZELIO/BEZEL 148 E/AZELIO/COA 148 E/AZELIO/R/ 147 E/AZELIO/R/RC 147 E/AZELIO/S/2 146 E/AZELIO/S/ST 146 E/BEZ/BK/1 124 E/BEZ/MM 123 E/BEZ/SOL 125 E/BHDA/2 162 E/BHDA/2/ID 162 E/BK/M3/LED/2 124 E/BK/M3/LED/2/ 124 E/CAMBER/ 136 E/CAMBER/SURF* 136 E/CAMBER/WALL* 136 E/CEILO/LED/ST 149 E/CHFO/FMB/BR 135 E/CHFO/FMB/SI 135 E/CHFO/FMB/WH 135 E/CHFO/M3/L/ 135 E/CHFO/M3/L/ 135 E/CHFO/M3/L/ 135 E/CHFO/M3/L/ 135 E/CHFO/WMB/BR 135 E/CHFO/WMB/SI 135 E/CHFO/WMB/ 135 E/CHVL/M3/L/ 137 E/CHVL/M3/L/ 137 E/CHVL/M3/L/ 137 E/COM/BKT/1 172 E/COM/EX172 E/COM/EX172 E/COM/EXP/22W 172 E/COM/EXP/22W/ 172 E/COM/EXP/22W/ 172 E/COM/EXP/37W 172 E/COM/EXP/37W/ 172 E/COM/EXP/37W/ 172 E/COM/EXP/47W 172 E/COM/EXP/68W 172 E/DA/M3/LED/3/ 137 E/DLDA/1/CO 159 E/DLDA/1/ID/CO 159 E/DLDA/1/ID/OA 159 E/DLDA/1/OA 159 E/DLDA/2/CO 160 E/DLDA/2/ID/CO 160 E/DLDA/2/ID/OA 160 E/DLDA/2/OA 160 E/DLDA/3/CO 161 E/DLDA/3/ID/CO 161 E/DLDA/3/ID/OA 161 E/DLDA/3/OA 161 E/EM/RC 123 E/EM/RC 124 E/EM/RC 130

Catalogue Code Page No. E/EM/RC 134 E/EM/RC 140 E/EM/RC 146 E/EM/RC 147 E/EM/RC 171 E/EX/M3 132 E/EXDA/1/AD 154 E/EXDA/1/ALR 154 E/EXDA/1/AU 154 E/EXDA/1/ID/AD 154 E/EXDA/1/ID/ALR 154 E/EXDA/1/ID/AU 154 E/EXDA/2/AD 155 E/EXDA/2/ALR 155 E/EXDA/2/AU 155 E/EXDA/2/ID/AD 155 E/EXDA/2/ID/ALR 155 E/EXDA/2/ID/AU 155 E/EXDA/3/AD 156 E/EXDA/3/AL 156 E/EXDA/3/AR 156 E/EXDA/3/AU 156 E/EXDA/3/ID/AD 156 E/EXDA/3/ID/AL 156 E/EXDA/3/ID/AR 156 E/EXDA/3/ID/AU 156 E/EXDA/4 157 E/EXDA/4/ID 157 E/EXDA/5 158 E/EXDA/5/ID 158 E/GL/LED/ 149 E/GL/LED/ 149 E/GLEN/3W 150 E/GLEN/BEZ/BK 150 E/GLEN/BEZ/SI 150 E/GR/M3/ULTRA 141 E/GR/NM3/LED/2 140 E/GR/NM3/LED/ 140 E/GR/NM3/LED/ 140 E/GU32 142 E/GU32/IP65 142 E/ME/LED/SRK/1 122 E/ME/M3/LED/ 122 E/ME/M3/LED/ 122 E/MILAN 171 E/MILAN/BEZ/BK 171 E/MILAN/BEZ/BR 171 E/MILAN/BEZ/CH 171 E/MILAN/EYE/BK 171 E/MILAN/EYE/WH 171 E/MILAN/M3 171 E/MILAN/M3/MW 171 E/MILAN/M3/ 171 E/MILAN/M3/RC 171 E/MILAN/MW 171 E/MM/BLADE 123 E/MM/M3/LED 123 E/PIC/AL/AD 130 E/PIC/AL/AL 130 E/PIC/AL/AR 130 E/PIC/ME/LED/ 122 E/PIC/ME/LED/ 122 E/PIC/ME/LED/ 123 E/PIC/ME/LED/ 124 E/PIC/RZ/PACK 133 E/RZ/M3/LED/F 133 E/RZ/M3/LED/H 133 E/RZ/M3/LED/R 133 E/RZ/M3/LED/W 133 E/SOHO 170 E/SOHO/M3 170 E/SOHO/M3/DA 164 E/SOHO/M3/ 164 E/SOHO/M3/MW 170 E/SOHO/M3/ 170


Catalogue Code Page No. E/SOHO/M3/RC 170 E/SOHO/MW 170 E/SOLENT/M3 125 E/STRATOS/110 126 E/STRATOS/110 172 E/STRATOS/230 126 E/STRATOS/230 172 E/STRATOS/24 126 E/STRATOS/24 172 E/STRATOS/50 126 E/STRATOS/50 172 E/STRATOS/COLD 126 E/STRATOS/HI 126 E/STRATOS/M3 126 E/STRATOS/ 126 E/STRATOS/PIC/ 126 E/STRATOS/PIC/ 172 E/STRATOS/REC/ 126 E/STRATOS/REC/ 172 E/STRATOS/ULTRA 127 E/TSDA/1 163 E/TSDA/1/ID 163 E9203 109 E9600 108 E9700 52 E9701 52 E9702 52 E9703 52 E9708 51 E9709 51 E9710 51 E9711 51 F/45681-705 213 F/45681-709 213 F/55000-740 213 F/55000-741 213 F/55000-742 213 F/55000-743 213 F/55000-744 213 F/55000-745 213 F/A80161M2 207 F/A81161M2 207 F/ACA-CT-025 229 F/ACAC-CP-025 229 F/ACC-EN WHT 217 F/AD105-0100 229 F/AD185-0100 229 F/AD68-0100 229 F/AD88-0100 229 F/ALN-EN WHT 217 F/ATJ-EN WHT 217 F/BASE/95 212 F/BASE/95/IS/WB 212 F/BASE/AS 200 F/BF431C/CC/W 191 F/BF451A/CX/SRC 213 F/BF456C/CC/W 191 F/C4403A1R 191 F/C4403A2 191 F/C4408D 191 F/C4414 191 F/C4416 191 F/CH/EDR/FLEX 231 F/CH/EDR/FLEX 264 F/CH/EDR/FLEX 268 F/CH/ER 231 F/CH/FVE 231 F/CH/HAK/1 191 F/CH/HAK/2 191 F/CH/HAK/3 191 F/CH/HDR/5 230 F/CH/MSM/95 228 F/CH/MX-5101 211 F/CH/MX-5201 211 F/CH/MX-5202 211

Catalogue Code Page No. F/CH/MX-5401 211 F/CH/MX-5402 211 F/CH/MX-5403 211 F/CH/MX-5404 211 F/CH/MX-5802 211 F/CH/MX-5802/FT 211 F/CH/MX-5803 211 F/CH/MX-5803/FT 211 F/CH/MX-5804 211 F/CH/MX-5804/FT 211 F/CH/MX-5805 211 F/CH/MX-5805/FT 211 F/CH/MX-5806 211 F/CH/MX-5806/FT 211 F/CH/MX-5807 211 F/CH/MX-5807/FT 211 F/CH/MX-5808 211 F/CH/MX-5808/FT 211 F/CH/PC 231 F/CH/PIP-001/1M 225 F/CH/PIP-002 225 F/CH/PIP-003 225 F/CH/PIP-005 225 F/CH/PIP-006 225 F/CH/PIP-007 225 F/CH/PIP-008 225 F/CH/PIP-009 225 F/CH/PIP-012 225 F/CH/PIP-014 225 F/CH/PIP-015 225 F/CH/PIP-016 225 F/CH/PIP-059-001 225 F/CH/PIP-059-007 225 F/CH/PIP-221-035 225 F/CH/PIP-222-059 225 F/CH/PS200 217 F/CH/SMOKESA235 F/CH/SOLO/100 235 F/CH/SOLO/101 235 F/CH/SOLO/108 235 F/CH/SOLO/200 235 F/CH/SOLO/330 235 F/CH/SOLO/423 235 F/CH/SOLO/424 235 F/CH/SOLO/460 235 F/CH/SOLO/461 235 F/CH/SOLO/610 235 F/CH/SOLO/726 235 F/CH/SOLO/760 235 F/CH/SOLO/808 235 F/CH/SOLO/809 235 F/CH/SOLO/810 235 F/CH/SOLO/811 235 F/CH/SOLO/812 235 F/CH/SOLO/814 235 F/CH/SOLO/822 235 F/CH/SOLO/823 235 F/CH/SOLO/CO 235 F/CH/SOLOA5 235 F/CH/VPS-215 225 F/CH/VPS-220 225 F/CH/VSP-005 225 F/CH/XPAND/SVU 223 F/CHAS/2 200 F/CHAS/4 200 F/CHAS/8 200 F/CHBG/AS/ 200 F/CHBG/AS/ 212 F/CHBG/IS/95/2 212 F/CHBG/S/5 195 F/CHBG/S/AS/2 200 F/CHBG/S/SA/CV 202 F/CHBG/S/SA/WP 202 F/CHBG/WP/5 195 F/CHBG/WP/95/1 212

Catalogue Code Page No. F/CHBG/XPAND 223 F/CHBGC/KIT 232 F/CHBGC/KIT/S 232 F/CHBL/6/2 195 F/CHBM/140/ 228 F/CHBM/70/KIT/2 228 F/CHBM/ADAPT228 F/CHB228 F/CHBM/R/50/95 228 F/CHBM/SA/2 228 F/CHBN/95 212 F/CHBN/BASE/95 212 F/CHBN/D/RING 195 F/CHBN/RD/DB 195 F/CHBN/SU/SA 202 F/CHDR/24 230 F/CHDR/240 230 F/CHDR/AUDIO 229 F/CHDR/BK 230 F/CHDR/CHAIN 230 F/CHDR/PSU/2 231 F/CHDR/PSU/4 231 F/CHEV/BGU 186 F/CHEV/PB 186 F/CHEV/SYN/BGU 186 F/CHEV/SYN/BS 186 F/CHEV/SYN/GSM 186 F/CHEV/SYN/HD 186 F/CHEV/SYN/INT2 186 F/CHEV/SYN/SD 186 F/CHEV/SYN/ 186 F/CHEV/SYN/SS 186 F/CHFA/SFS 232 F/CHHF/A 195 F/CHHF/A/HT 195 F/CHHF/A/HT/AS 200 F/CHHF/AS 200 F/CHHF/HT/AS/ 200 F/CHHM/95 212 F/CHHM/DISC 214 F/CHHM/HT/95 212 F/CHHM/HT/WB/ 223 F/CHHM/HT/WB/ 223 F/CHHM/WB/BN/ 223 F/CHHM/WB/ 223 F/CHHM/XPAND 223 F/CHHR/A/65 195 F/CHHR/A/HT/65 195 F/CHHR/AS/WB 200 F/CHHR/AS/ 200 F/CHHRT/SA/PRO 202 F/CHIF/XPAND 223 F/CHIO/1/95 212 F/CHIO/1/95/240 212 F/CHIO/2/95 212 F/CHIS/95/DB 212 F/CHQ-ADAPTER 217 F/CHQ-DSC2/SCI 217 F/CHQ-DZM/SCI 217 F/CHQ-MRC2/SCI 217 F/CHQ-POM 217 F/CHQ-SIM 217 F/CHQ-SZM2/SCI 217 F/CHQ-WPK 217 F/CHQ-WS2 217 F/CHQ-WSB2/RL 217 F/CHRI/60 195 F/CHRI/60 202 F/CHRI/60 233 F/CHRI/AS 200 F/CHRI/AS 233 F/CHRM/AS 200 F/CHRM/AS 200 F/CHSA/2/PRO 202 F/CHSA/2/PRO/ 202

Catalogue Code Page No. F/CHSA/4/PRO 202 F/CHSA/4/PRO/ 202 F/CHSA/4/PRO/ 202 F/CHSA/4CONV 202 F/CHSA/8/PRO 202 F/CHSA/8/PRO/ 202 F/CHSA/PRO2/R 202 F/CHSA/SH/PRO 202 F/CHSA/SHS/PRO 202 F/CHSA/SHSB/ 202 F/CHSC/2 195 F/CHSC/2/E 194 F/CHSC/4 195 F/CHSC/4/E 194 F/CHSC/8 195 F/CHSC/8/E 194 F/CHSC/R 195 F/CHSC/R 200 F/CHSC/RDC 195 F/CHSC/RDC 200 F/CHSG 232 F/CHSM/A/DISC 214 F/CHSM/M/95 212 F/CHSM/M/DISC 214 F/CHSM/P 195 F/CHSM/P 227 F/CHSM/P/65 195 F/CHSM/P/95 212 F/CHSM/P/AS/WB 200 F/CHSM/P/AS/ 200 F/CHSM/P/DISC 214 F/CHSM/P/WB/ 223 F/CHSM/P/WB/ 223 F/CHSM/P/WB/ 223 F/CHSM/P/XPAND 223 F/CHSN/95 212 F/CHSU/I/SA 202 F/CHSU/SA 202 F/CHSW/95 212 F/CHSW1/SA 202 F/CHWB/95/AP 212 F/CHWB/AS/CAP/ 200 F/CHWB/BN/95/A 212 F/CHWB/BN/95/ 212 F/CHWB/BN/95/ 212 F/CHWB/BN/ 214 F/CHWB/BN/ 200 F/CHWB/BN/ 195 F/CHWB/D 195 F/CHWB/D/AS 200 F/CHWB/D/BN/AS 200 F/CHWB/D/COV195 F/CHWB/IS/ 212 F/CHWB/R 195 F/CHWB/RD/AS 200 F/CHWB/RD/DB 195 F/CHWB/XPAND 223 F/CHZM/IS/95 212 F/CLOOM 191 F/COVER/RD/1 212 F/COVER/WH/1 212 F/COVER/WH/1 212 F/E01020L2 197 F/E01040L2 197 F/E01080L2 197 F/EDA-A6000 221 F/EDA-A6030 221 F/EDA-A6040 221 F/EDA-A6041 221 F/EDA-A6060 221 F/EDA-C5000 221 F/EDA-D5000 221 F/EDA-D6000 221 F/EDA-Q585 221 F/EDA-R5000 221

Catalogue Code Page No. F/EDA-R6000 221 F/EDA-R6030 221 F/EDA-T6080 221 F/EDA-Y5000 221 F/EDA-Z5000 221 F/EDA-Z5008 221 F/EDA-Z5020 221 F/EDA-Z5100 221 F/EDA-Z6000 221 F/EDA-Z6010 221 F/EDA-Z6011 221 F/FFE-16511 237 F/FFE-16519 237 F/FFE-16521 237 F/FFE-16571 237 F/FFE-16579 237 F/FFE-16581 237 F/FFE-16589 237 F/FFE-16591 237 F/FL5000-200APO 216 F/FL5100-600APO 216 F/FL6100-600APO 216 F/FW1001/1/16 206 F/FW1001/2/32 206 F/FW1001/HB 206 F/FW1001/ 206 F/FW1001/ 206 F/FW1001/R/16 206 F/FW1001/R/32 206 F/GE8829 227 F/H80161M2 207 F/H81161M2 207 F/HCP-E/SCI 217 F/HCP-W/SCI 217 F/HCV500/0350 227 F/HCV500/0600 227 F/HCV500/0800 227 F/HCV500/1000 227 F/K01020M2 197 F/K01040M2 197 F/K01080M2 197 F/KA11020M2 197 F/KA11040M2 197 F/KA11080M2 197 F/KEY BOX 232 F/KEY BOX GLASS 232 F/KL11020M2 197 F/KL11040M2 197 F/KL11080M2 197 F/LA80161M2 207 F/LA81161M2 207 F/LH80161M2 207 F/LH81161M2 207 F/PSU/12/1/BM 233 F/PSU/12/1/BM 253 F/PSU/12/2/BM 233 F/PSU/12/3/BM 233 F/PSU/12/5/BM 233 F/PSU/24/1/BM 233 F/PSU/24/2/BM 233 F/PSU/24/3/BM 233 F/PSU/24/5/BM 233 F/PSU24/1.5/ 228 F/PSU24/1.5/ 233 F/PSU24/3/ 233 F/SA5000-200APO 215 F/SA5000-400APO 215 F/SA5000-600APO 215 F/SA5000-700APO 215 F/SA5100-400APO 215 F/SA5100-600APO 215 F/SA5100-700APO 215 F/SI/CAP2WHT 217 F/SR/MOUNTING 217 F/SVM/24V-5A/ 227

Index

Index

3 285

t:t:0845 884 7000 sales.lfs@deta.co.uk w:deta.co.uk deta.co.uk 285 01582 544 544 | | e:e: sales@deta.co.uk | | w:


Index Catalogue Code Page No. F/SVM/24V-8A/ 227 F/TCH-B200 217 F/VAD/C/1 196 F/VAD/C/3 196 F/VAD/W/1 196 F/VAD/W/3 196 F/VAD/WB/C/2 196 F/VAD/WB/C/4 196 F/VAD/WB/W/2 196 F/VAD/WB/W/4 196 F/VEA-040-A00 225 F/VEA-040-A10 225 F/VEP-A00-P 225 F/VEP-A10-P 225 F/VEU-A00 225 F/VEU-A10 225 F/ 227 F/YBN/R/3 WHT 217 F/YBN/R/3/SCI 217 F/YBO-BS WHT 217 F/YBO-BSB217 F/YBO-R/3 RED 217 F/YBO-R/3/WHT 217 F/YBO-R/SCI RED 217 F/YBO-R/SCIWHT 217 GF6010 47 GF6011 47 GF6012 46 GF6013 46 GF621 47 GF622 46 GF623 47 GF625 46 I/CH/AMD 241 I/CH/AML 241 I/CH/AMP 241 I/CH/AMR 241 I/CH/AMR/H 241 I/CH/AMT 241 I/CH/APJ 241 I/CH/APL 241 I/CH/APM 241 I/CH/APM 241 I/CH/APQL 241 I/CH/APQM 241 I/CH/APXL 241 I/CH/APXM 241 I/CH/BELDEN/25 241 I/CH/FLAT/2005 241 I/CH/FLAT/3005 241 I/CH/FPROK/1 242 I/CH/PIL/L 242 I/CH/PRO45 241 I/CHIL/103C 240 I/CHIL/103L 240 I/CHIL/103R 240 I/CHIL/11/DD 240 I/CHIL/11/DW 240 I/CHIL/11/SD 240 I/CHIL/11/SW 240 I/CHIL/200E 240 I/CHIL/5/DWA 240 I/CHIL/5/SD 240 I/CHIL/5/SW 240 I/CHIL/7/DD 240 I/CHIL/7/DW 240 I/CHIL/7/SD 240 I/CHIL/7/SW 240 I/CHIL/K1 240 I/CHIL/K2 240 I/CHIL/K3 240 I/CHIL/ML1 242 I/CHIL/ML1/K 242 I/CHIL/PDA5/DD 240 I/CHIL/PL1 242

286

t: 0845 01582884 5447000 544

||

Catalogue Code Page No. I/CHIL/PL3 242 I2012B 8 I2012W 8 I2013B 9 I2013W 9 I2014B 10 I2015B 11 I2022B 8 I2022W 8 I2023B 9 I2023W 9 I2024B 10 I2025B 11 I2032B 8 I2032W 8 I2033B 9 I2033W 9 I2034B 10 I2035B 11 I2042B 8 I2042W 8 I2043B 9 I2043W 9 I2044B 10 I2045B 11 L1402WH3 67 L1402WH4 67 L1409CH 67 L1409SS 67 L2305 53 L2305LED3 53 L2305LED4 53 L2309B 27 L2309W 27 MULTIZONE 227 N/CC/910/EF 253 N/CC/910/ES 253 N/CC/910/F 253 N/CC/910/S 253 N/CC/920/EF 253 N/CC/920/ES 253 N/CC/920/F 253 N/CC/920/S 253 N/CC/930 253 N/CC/941 253 N/CC/941/B 253 N/CC/941/SS 253 N/CC/944 253 N/CH/802DB 253 N/CH/802DEM 253 N/CH/802DEWM 253 N/CH/802DEWS 253 N/CH/802DM 253 N/CH/803M 249 N/CH/803M 253 N/CH/804DE 253 N/CH/805/14 249 N/CH/805/14 253 N/CH/805C/6 249 N/CH/805C/6 253 N/CH/806C 249 N/CH/806C 253 N/CH/806CS 249 N/CH/806CS 253 N/CH/807C 253 N/CH/809DB 253 N/CH/888D 253 N/CH/894DKB 253 N/CH/894DKM 253 N/CH385 249 N/CHWB/ 247 N/HARK/1 247 N/HARK/1/PB 247 N/HARK/1/PC 247 N/HARK/1/PSU 247

Catalogue Code Page No. N/HARK/1/RS 247 N/HARK/CA 247 N/HARK/RI/1 247 N/HARK/RI/1/SS 247 N/HARK/RI/2 247 N/HARK/RI/2/SS 247 N/HARK/RI/3 247 N/HARK/RI/3/SS 247 N/HARK/RI/4 247 N/HARK/RI/4/SS 247 N/HARK/RI/5 247 N/HARK/RI/5/SS 247 N/HARK/RI/6 247 N/HARK/RI/6/SS 247 N/HARK/RI/7 247 N/HARK/RI/7/SS 247 N/HARK/RI/8 247 N/HARK/RI/8/SS 247 N/HARK/RI/9 247 N/HARK/RI/9/SS 247 N/HARK+ 247 N/HARK+/PB/SS 247 N/HARK+/PC/SS 247 N/HARK+/PSU/SS 247 N/HARK+/RS/SS 247 N/QT1001/S 249 N/QT302RX 249 N/QT302RXRS 250 N/QT412RXA 249 N/QT412RXA 250 N/QT423 249 N/QT423 250 N/QT601-2 249 N/QT601-2 250 N/QT602 249 N/QT602M 249 N/QT602R 249 N/QT603 249 N/QT603 250 N/QT604 249 N/QT606 249 N/QT606 250 N/QT606A 249 N/QT606A 250 N/QT607 249 N/QT608C 249 N/QT608C 250 N/QT608CD 249 N/QT608CD 250 N/QT609 249 N/QT609R 249 N/QT609S 249 N/QT611 249 N/QT611 250 N/QT630 250 N/QT633 250 N/QT636 250 N/QT638 250 N/QT661 249 N/QT688 249 N2011 26 N2012 26 N2013 26 N2014 26 N6045 14 N6046 16 N6047 15 N6055 14 N6056 16 N6057 15 N6065 14 N6066 16 N6075 14 N6085 14 N6086 16

e: deta.co.uk e:sales.lfs@deta.co.uk sales@deta.co.uk | | w:w: deta.co.uk

Catalogue Code Page No. N6279 78 N6280 78 N6281 78 N6282 78 N6283 78 N6310 14 N6311 15 N6320 14 N6321 15 N6330 14 N6331 15 N6340 14 N6341 15 N9103 31 P1000 96 P1010 96 P1020 97 P1025 97 PR1005L 93 PS20 26 PS21 26 PS41 26 PS41R 26 PS45 83 R/CH/BF359/1 258 R/CH/BF359/2B 258 R/CH/BF359/3CL 258 R/CH/BF359/3M 258 R/CH/BF359/3SL 258 R/CH/CATCON 258 R/CH/ECU-224 258 R/CH/ECU-723 258 R/CH/ECU-PPT 258 R/CH/EVC301/JP 258 R/CH/EVC301RLK 258 R/CH/EVC301RPO 258 R/CH/EVC301R258 R/CH/EVC302F 258 R/CH/EVC302GF 258 R/CH/EVC302GS 258 R/CH/EVC302S 258 R/CH/EVC385 258 R/CH/EVC401/PH 258 R/CH/EVC423/PC 258 R/CH/FITT/R/CH/ 258 R/CH/ORB-L255 R/CH/ORB-L255 R/CH/ORB-L255 R/CH/ORB-L255 R/CH/ORB-L-RS4255 R/CH/ORB-L-RS4255 R/CH/ORB-L-RS8255 R/CH/ORB-L-RS8255 R/CH/ORB-R-RS4255 R/CH/ORB-R-RS4255 R/CH/ORB-R-RS8255 R/CH/ORB-R-RS8255 R/CH/ORB/R/ 255 R/CH/ORB/R/ 255 R/CH/RCO/F/ 255 R/CH/RCO/FL/ 255 R/CH/RCO/H/GB 255 R/CH/RCO/H/ 255 R/CH/RCO/S/ 255 R/CH/RCO/S/L/ 255 R/CH/SDM 258 R/CH/T-BEZ301 258 R/CH/T-BEZ301/ 258 R/CH/XSB 258 R/ECU-16 258 R/ECU-4 258 R/ECU-8 258 R/ECU-8NT 258 R/ECU722 258 R1010 92

Catalogue Code Page No. R1020 92 R8019 56 R8027 56 R8036 57 R8054 57 R8080 57 R8100 57 S/BATT/EDA-Q690 221 S/BG/COVER/SA 202 S/BG/TESTKEY/AS 200 S/BG/TESTKEY/AS 212 S/BG/TESTKEY/SA 202 S/CH/BF376 230 S/CP/COVER 195 S/CP/KEY 195 S/E15/A 230 S/E20/A 200 S/E55/A 230 S/E60/A 230 S/E60/A 265 S/K14060 207 S/K18002 207 S/K555 207 S/K586A 207 S/K586H 207 S/K768P2 207 S/LEG/DA/AD/3 137 S/LEG/DA/AL/3 137 S/LEG/DA/AR/3 137 S/LEG/FO/AD 135 S/LEG/FO/ALR 135 S/LEG/VL/AD 137 S/LEG/VL/ALR 137 S/M2FCLGT 207 S/X187LS 207 S/XPERT TAG 223 S/XPERT TAG/WH 223 S2010 102 S3010 101 S3020 101 S3030 101 S3040 102 S4010 100 S4100 79 S4110 100 S4120 100 SE1030 86 SE1040 86 SE2010 86 SE3010 87 SE3020 87 SE3030 87 SE3040 87 SE3050 87 SE3070 87 SE3090 87 SE3110 87 SEFL13B 91 SEFL13E 91 SEFLKITINT 90 SEFLLEDBC 91 SEFLLEDES 91 SEK001 113 SEK002 113 SEPC 92 SP/BX/AD/DG 132 SP/BX/AD/DG/EN 132 SP/BX/AL/DG 132 SP/BX/AL/DG/EN 132 SP/BX/AR/DG 132 SP/BX/AR/DG/EN 132 SP/BX/AU/DG/EN 132 SP/CHBM/140/KIT 228 SP/CHBM/70KIT 228 SP/CHSM/P/AS 200


Index Page No. 170 170 113 63 63 63 63 63 63 63 63 65 65 65 65 65 65 65 65 65 208 208 208

Index

Catalogue Code SP/SOHO/M3/ SP/SOHO/M3/ST SPAXA T2041 T2042 T2051 T2052 T2061 T2062 T2081 T2082 T3071 T3072 T3073 T3074 T3075 T3076 T3077 T3078 T3079 TOUCH-10 TOUCH-10-SBB TOUCH-10/FT

5 287

t: 0845 884544 7000 t: 01582 544 | | e: sales.lfs@deta.co.uk e: sales@deta.co.uk

||

w: deta.co.uk w:

287


Deta Electrical Company Limited Panattoni Park, Luton Road, Chalton, Bedfordshire, LU4 9TT t: 0845 884 7000 e: sales.lfs@deta.co.uk w: deta.co.uk

t: 0845 884 7000

|

e: sales.lfs@deta.co.uk

|

w: deta.co.uk


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.