CONCLUSIONS
Figure 4.34 A representative scheme of FRM technique on both sides
4.6.2 RC buildings For the RC buildings have been decided to apply another intervention. Most of the building studied are formed by the ground floor where it is concentrated the commercial section and the other floors have a residential function. The ground floor is composed by only columns in order to have big openings for the stores. The upper floors have unreinforced masonry walls (see Figure 4.35 and Figure 4.36). Because of difference of stiffness and strength between different floors, the interventions will be concentrated to RC columns of the ground floor. In particular, jacketing of RC columns have 144