evomover - install into the cabinet
Installation into the cabinet min.57
image 1 [mm]
35
A
L = A -10
35
35
80
*ground clearance min. 20 mm
1/2 B
1/2 B
* installation of cabling for the bottom cabinet is necessary to meet minimum ground clearance. 20 mm (from the bottom of the drawer to bottom cabinet)
switch Power full - half
switch Mode multiple - single
B A - internal cabinet height [mm] B - internal cabinet width [mm] L - bracket pofile length (L = A - 10) [mm]
connection for synchronisation cable light Power Assembly for more pull-out strength Assembly note.: distribution cable snap of distribution cable by holders is recommended every 70 to 100 mm.
When more pull-out strength is necessary, connect drive units to multiple mode (two drive units that need to open simultaneously must be connected via the synchronisation cable, then toggle mode switch to multiple and toggle power switch to full).