Sym 2012cat valve v290 en

Page 1

CAT.10111E-S

www.sym21.com

LV290 series Universal 3-port UV280 series Large flow capacity 2-port V200 series Micro 3-port V190 series Latching type 3-port

V290 Series Compact size with large flow capacity Body width: 7.4 mm Effective area: V10 - 0.2 mm2 (Cv 0.011) Body width: 9.9 mm Effective area: V290 - 0.3 mm2 (Cv 0.018), V290U - 0.5 mm2 (Cv 0.028) LV290 - 0.2 mm2 (Cv 0.011), UV280 - 1.2 mm2 (Cv 0.066) V290 - 1.5 mm2 (Cv 0.083)

Available ranging from vacuum to 0.7 Mpa Low power consumption Less than 1W (can be directly driven in the PLC system)

Exceedingly long life More than 200 million cycles (Life test data by SYM)

Filter inserted (P, A Port) Prevention of polluted air of internal piping

Wiring and distribution wires measured designed Newly designed manifold block and various wiring types

Freely use of N.C. and N.O. (Universal type)

V290 Series

2路3 Port Solenoid Valve /Direct Poppet Type

V290

LV290

UV280

V200

V190


INDEX Standard type 3-port

V290 series [p.8~p.11]

■ How to order ..................................................... 8 ■ Specifications ................................................... 9 ■ Dimensions .........................................................10

V290-P V290-

V290- N.C.

R (3)

A (2)

P (1)

Air blow

V280-

V290-

N.C.

N.O.

A (2)

P (1)

Operation of the singleacting cylinder

Latching type 3-port

Vacuum pad

3 (R)

2(A)

3(R)

2(A)

1 (P)

1(P)

A (2)

1(P)

2(A)

2(A)

3(R) 1(P)

P (1)

3-port Valve

For controlling the air pilot valve

(Normally Closed Type)

3-port Valve

(Normally Open Type)

Selector Valve Divider Valve

LV290 series [p.12~p.14] LV290-4E SET

SET

R (3)

A(2) RESET

P (1)

Air blow

R (3) P (1)

Air operated valve

SET

R (3)

A (2) RESET

Operation of the singleacting cylinder

3(R)

A (2)

2(A)

1(P)

RESET

P (1)

LV290V-4E

For controlling the air pilot valve

For a vacuum

UV280 series [p.15~p.17]

■ How to order .....................................................15 ■ Specifications ...................................................16 ■ Dimensions .........................................................17

UV280-Q

UV280-E

1. 3-port Valve

2. 3-port Valve

3. 2-port Valve

A (2)

A (2)

A (2)

(Normally Closed Type)

R (3)

(Normally Open Type)

R (3)

P (1)

P (1)

(Normally Closed Type)

R (3)

4. 2-port Valve

(Normally Open Type)

5. Selector Valve

A (2)

P (1)

R (3)

A (2)

P (1)

Manifold Block [p.18~p.19] ■ How to order .....................................................18 ■ Dimensions .........................................................19

2

V290-Q

V280V-

3(R)

R (3)

A (2)

For a vacuum

■ How to order .....................................................12 ■ Specifications ...................................................13 ■ Dimensions .........................................................14

Universal 3-port

V290-L

Air operated valve

N.C.

R (3)

R (3) P (1)

V290-E

Horizontal type

Vertical type

R (3)

6. Divider Valve A (2)

P (1)

R (3) P (1)


INDEX Large flow capacity 2-port

V200 series [p.20~p.22]

■ How to order .....................................................20 ■ Specifications ...................................................21 ■ Dimensions .........................................................22

V200-P

V200-E

V200-

V200V- P

RESET

A P

A

P

A

A

1(P)

2(A)

P

Valve for the air blow

Valve for a vacuum

LV200V-

Valve for the vacuum ejector

Valve for a vacuum

1(P) SET

2(A)

Valve for a vacuum

Manifold Block [p.23] Horizontal type

Micro 3-port

Vertical type

V190 series [p.24~p.26]

■ How to order .....................................................24 ■ Specifications ...................................................25 ■ Dimensions .........................................................26

V190-P

V190-E

Manifold Block [p.27] Horizontal type

P-type Plug Connector

E-type Plug Connector

3


PRECAUTION

Be sure to read before handling.

These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by a label of Caution, Warning, or Danger. To ensure safety, be sure to observe ISO44141), KS B 63762) and other safety regulations.

Caution

Operator error could result in injury or equipment damage.

Warning

Operator error could result in serious injury or loss of life.

Danger

In extreme conditions, this could result in serious injury or loss of life.

1) ISO 4414: Pneumatic Fluid Power-Recommendations for the application of equipment to transmission and control systems. 2) General Rules for Pneumatic System.

Caution 1. The pneumatic equipment shall be selected by pneumatic system designers or professionals. The person decides specifications and has a responsibility for the performance and safety.

2. Only trained person should operate pneumatically operated machinery and equipment. Compressed air can be dangerous if an operator is unfamiliar with it. Assembly, handling or repair of pneumatic systems should be performed by a trained and experienced operator.

3. Don't remove components until safety is confirmed. 1) Inspection of machinery and equipment should only be performed after confirmation of safe locked-out control positions. 2) When equipment is to be removed, confirm the safety process as mentioned above. Cut the supply pressure for this equipment and exhaust all residual compressed air in the system. 3) When restarting, take measures to prevent shooting-out of cylinder piston rod, etc.

4. Take care if the product is to be used in any of the following conditions. Please feel free to contact us if you have questions. 1) Conditions and environments beyond the given specifications, or if product is used outdoors. 2) Installation on equipment in conjunction with food and beverages, medical equipment, vehicles, nuclear energy, railway, airplane, emergency stop circuits, press clutches, brake equipment or safety equipment. 3) An application requiring special safety.

4


PRECAUTION

Be sure to read before handling.

Air Supply

Warning 1. Use clean air Use clean air which doesn't contain chemicals, synthetic oils containing organic solvents, salts or corrosive gases etc., because this can cause damage or malfunction.

Caution

Valve Operation

Warning 1. Actuator drive When an actuator is to be driven using a solenoid valve, take appropriate measures to prevent potential danger caused by actuator operation. 2. Since valves are subjected to air leakage, they cannot be used for applications such as holding pressure. 3. Can't be used as an emergency shutoff valve, etc.

1. Filteration to 5Âľm is recommended. 2. Large quantity of drainage may cause incorrect operation of pneumatic products as well as environmental contamination. Please control drainage. You can use the filter with auto drainage in case of difficulty. 3. When there is a large amount of carbon powder from the compressor, please install a mist separator.

Installation

Warning 1. Confirm the specifications Don't operate at pressures or temperatures beyond the range of specifications, because this can cause damage or malfunction.

Environment

Warning 1. Keep away from corrosive gas, chemical solutions, sea water, rain and steam. 2. Avoid using in an explosive atmosphere. 3. Don't use in locations subject to vibration or impact. 4. Avoid direct sunlight. 5. Shield radiated heat generated by nearby heat sources. 6. Use a protective cover when installed in a place where a drop of water or oil will splash momentarily. 7. Please install a silencer on the exhaust port when installed in a dusty place.

Lubrication

Caution 1. No further lubrication is required because valves are prelubricated. 2. Please use turbine oil (ISO VG32 or equivalent to) if lubricant is required. Once lubrication is applied, it must be continued, because the original lubricant may be eliminated.

Caution 1. Leakage voltage 1) Residual leakage voltage of DC coil must be less than 2% when switch is OFF. 2) When using a C-R element, there might be a chance to increase the leakage voltage. 2. Low temperature operation Avoid ambient temperatures outside the range prescribed in the specifications. At low temperatures, appropriate measures should be taken to avoid solidification of freezing of drainage and moisture, etc. 3. Operation for air blowing When using solenoid valves for air blowing, an external pilot type or direct solenoid operated type should be used. Also, supply compressed air within the pressure range prescribed in the specifications, especially for an external pilot type.

Low temperature operation

Caution 1. B e careful of solidification or freezing such as drainage water at a low temperature below than 5°C.

5


PRECAUTION

Be sure to read before handling.

How to use Plug Connector Crimping area

Caution

Core wire crimping area

Core wire

1. Connection/Disconnection of connector

Lead wire

1) Push the connector straight onto the pins of the solenoid, making sure the lip of the lever is securely positioned in the groove of the solenoid cover.

Hook

Insulation cover

2) Press the lever and pull the connector away from the solenoid.

Pin

Manual Operation

Warning 1. Without an electric signal for the solenoid valve, the manual operation is used for switching the main valve. Polarity indication (DC) Hook Lead wire

Groove

2. Make sure that there is no danger, since manual operation can make any connected equipment operate. Push type

Connector lever Socket

It is turned ON by pushing the button in the direction indicated by the arrow until it hits the end and turned OFF by releasing the button.

2. Connection/Disconnection of socket with lead wire 1) Insert a socket into the square hole of connector, pushing fully the lead wire and lock by hanging the hook of socket to the seat of connector. (Pushing-in can open the hook and lock it automatically.) Then confirm the locking by light pulling of the lead wire. 2) For pulling-out the socket from the connector, pull out the lead wire while pushing the hook of socket by a stick with a fine point. If the socket is re-used as it is, reposition the hook again.

Warning

Connector

Socket

Hook

Maintenance

Lead wire

1. When equipment is removed, first confirm that measures are in place to prevent dripping of work pieces and runaway of equipment, etc. Then cut the supply pressure and power, and exhaust all compressed air from the system using its residual pressure release function. When the equipment is to be started again after remounting or replacement, first confirm that measures are in place to prevent lurching of actuators, etc., and then confirm that the equipment is operating normally. 2. Although don't use frequently, operate the valve regularly to prevent malfunction.

3. Crimping connection of lead wire and socket 1) Peel 3.2 to 3.7 mm of the tip of lead wire, insert the core wires into a socket and crimp using a crimping tool. 2) Be careful so that the insulation cover of lead wire does not interface with the crimping part. 6

Caution 1. Drainage removal Remove drainage regularly from air filter.


PRECAUTION

Be sure to read before handling.

Latching type valve (LV290)

Universal type valve (UV280)

Caution

Caution

Latching type valve is designed to prevent malfunction in case of the momentary power interruption. It is advised to apply a consecutive electric current to the SET coil and a momentary electric current (over 10 ms) to the RESET coil. Even though Latching type valve is supplied as the RESET condition (A-R), it can be turned to the SET condition because of the external shock or vibration during the handling. So you should check the power condition before the first use.

UV280 is designed to use normal close (N.C.) and normal open (N.O.) freely just by selecting the port for supply. So you can select any port for the supply or exhaust as 6 methods below.

1. 3-port Valve

(Normally Closed Type)

2. 3-port Valve

(Normally Open Type)

A(2)

3. 2-port Valve

(Normally Closed Type)

A(2)

A(2)

Lamp and Surge Voltage Suppressor When an electric current is applied to the SET side ,the red lights come on the indicator lamp of latching type valve. On the other way, when an electric current is applied to the RESET side, the green lights come on. Its coil is 5 mm longer than that of normal single type valve (V290).

R(3)

P(1)

4. 2-port Valve

(Normally Open Type)

R(3)

5. Selector Valve

A(2)

SET

RESET

RED LAMP

GREEN LAMP

R(3)

P(1)

A(2)

P(1)

R(3)

R(3)

P(1)

6. Divider Valve A (2)

P(1)

R (3) P (1)

Large flow capacity 2-port valve (V200) A

COMMON

B

Caution V200 valve, 10 mm width 2 port valve, is designed to use for air blow or vacuum ejector. As SYM's own creative model, its 10mm width can cover the effective area ranging from 1.5 mm2 to 2.0 mm2.

7


V290 Series

3-port Solenoid Valve / Direct Poppet

■ HOW TO ORDER V 2 9 0

- 4

- M5

P

● PORT SIZE -

ACTUATION ● Normally open type

R (3) P (1)

COIL RATED VOLTAGE ●

A(2)

9 1

AC 110V

2

AC 220V

3

DC 12V

Standard type

4

DC 24V

U

Large flow capacity type

6

DC 6V

V

For a vacuum

9

Special orders

R (3) P (1)

USING TYPE ● -

With sub-base

● LAMP AND SURGE VOLTAGE SUPPRESSOR

A(2)

8 Normally closed type

Without sub-base

M5

-

Standard type (Non-polar)

Z

Polar lamp - with Diode (DC)

S

Non-polar lamp - with surge voltage suppressor (DC)

■ DC Circuit Diagram (-)(+)

(Standard type)

CONNECTOR ●

(no connector)

SOL.

DC

SOL.

-

AC voltages are not availble for P-type plug connector. P-type Plug Connector

DC

+

(Z type)

(with 300 mm lead wire)

SOL.

(+)(-)

Only V280V is available for a vacuum.

P-type Plug Connector

DC

(-)(+)

(S type) (+)(-)

P

■ AC Circuit Diagram

PN

R R AC110V

E-type Plug Connector

E-type Plug Connector

(with 300 mm lead wire)

(no connector)

R

LED

D

LED

D

SOL.

R

E

EN

R AC220V R

SOL.

R

Q-type Plug Connector

Q-type Plug Connector

(with 300 mm lead wire)

(no connector)

Q

■ HOW TO ORDER CONNECTOR

QN

CA2 - V4 - 6 Lead wire type

Lead wire type

(with 300 mm lead wire)

(with 600 mm lead wire)

L

● LEAD WIRE LENGTH 6 10 15 20 25 30 50

Connector assembly

COIL RATED VOLTAGE ●

LL

V1

AC 110V

V2

AC 220V

V4

DC voltage

300 mm 600 mm 1,000 mm 1,500 mm 2,000 mm 2,500 mm 3,000 mm 5,000 mm

EX) USE OF THE VALVE V290-

V290- N.C.

R (3)

A (2)

P (1)

Air blow

8

V280-

V290-

N.C.

R (3)

R (3) P (1)

N.O.

A (2)

Operation of the singleacting cylinder

P (1)

Vacuum pad

Air operated valve

3(R)

R (3)

A (2)

For a vacuum

V280V-

N.C.

A (2)

2(A)

1(P)

3 (R)

2(A)

1 (P)

3(R)

2(A)

1(P)

3(R)

2(A)

1(P)

P (1)

For controlling the air pilot valve

3-port Valve

(Normally Closed Type)

3-port Valve

(Normally Open Type)

Selector Valve

Divider Valve


■ PARTS DRAWING

V290 Series

V290 (Normally closed) NORMAL 2

3

ENERGIZED

4 1

5

6 R

A

P

7

No.

Part's name BODY

8

Material PLASTIC

COIL ASS’Y

-

FIXED CORE

SUS

MOVING CORE

SUS, PLASTIC

POPPET

NBR

GASKET

NBR

SCREW

-

BASE

Zn

■ SPECIFICATIONS Model

Items

V290

V290U

Valve Structure

V280V 3)

Direct-acting Poppet type

Fluid

Air or insert gas

P(1) A(2)

0~0.7 MPa (0~7.1 kgf/cm )

0~0.6 MPa (0~6.0 kgf/cm2)

0~0.7 MPa (0~7.1 kgf/cm2)

-100 kPa~0.2 MPa (-0.1~2.0 kgf/cm2)

0.3 mm2 (Cv 0.018)

0.5 mm2 (Cv 0.028)

0.2 mm2 (Cv 0.011)

0.3 mm2 (Cv 0.018)

2

Pressure range Effective area

V280

A(2) R(3)

2

0.4 mm (Cv 0.024)

1)

2

2

0.5 mm (Cv 0.028)

0.2 mm (Cv 0.011)

Ambient and fluid temperature

Max. 50°C 2)

Response time

5 ms or less

Lubrication

Not required

Manual operation

Push Type

Shock / Vibration resistance

150/30 (m/s2)

Protection structure

Dust proof

Coil rated voltage

DC 6V, 12V, 24V / AC 110V, 220V

DC 6V, 12V, 24V

Allowable voltage

±10% of rated voltage

Coil insulation

Class B or equivalent ( 130°C)

Power consumption

DC: 1W / AC 110V: 1.0VA / AC 220V: 2.0VA

0.4 mm2 (Cv 0.024)

DC 6V, 12V, 24V / AC 110V, 220V

1) Spec of high pressure (0~0.7 Mpa, Power consumption DC: 1.4W) is made to order. 2) There should be a measure to prevent freezing and dew condensation at a low temperature below 5°C. 3) V280 is universal type valve for a vacuum.

9


■ DIMENSIONS

V290 Series

V290 - 4 P-M5 P-type Plug Connector (DC voltage)

MANUAL BUTTON

12.4 14.8

7.5

R 2-Ø2.7

~ 300 =

12 18

3.7

40.5

3-M5

5

P 1

5

5

3

R

7

5

A 2

11

29.5

9.9

5

29.2

V290 - 4 E-M5 E-type Plug Connector (DC voltage)

MANUAL BUTTON

12.4 14.8

9.9

7.5

R 2-Ø2.7

3.7

5

10

3-M5

29.2

P 1

5

3

5

R

7

5

A 2

11

29.5

39.5

~ 300 =

12 18

5


■ DIMENSIONS

V290 Series

V290 - 4 Q-M5

V290 - 4 L-M5

Q-type Plug Connector (DC voltage)

Lead wire type (DC voltage) 7.5

7.5

MANUAL BUTTON

12.4 14.8

9.9

MANUAL BUTTON

R 12 18

2-Ø2.7

3.7

~ 300 =

3.7

29.5

35.2

12 18

~ 300 =

2-Ø2.7

R

3-M5

3-M5

29.2

5

3

R

5

3

R

29.2

V290 - 2 E-M5 E-type Plug Connector (AC voltage)

7.5

12.4 14.8

9.9

MANUAL BUTTON

R 2-Ø2.7

3.7

~ 300 =

12 18

A C B

5

3-M5 34.2

3

P 1

5

R

5

7

5

A 2

11

29.5

39.5

B C A

5

11


LV290 Series

A(2) RESET

SET

Latching type Solenoid Valve / 3-port Direct Poppet

R(3) P(1)

■ HOW TO ORDER LV 290

- 4

E - M5

LATCHING TYPE VALVE (LV290) ●

● PORT SIZE

Latching type valve is designed to prevent malfunction in case of the momentary power interruption. It is advised to apply a consecutive electric current to the Set coil and a momentary electric current (over 10 ms) to the Reset coil. Even though Latching type valve is supplied as the Reset condition (A-R), it can be turned to the Set condition because of the external shock or vibration during the handling. So you should check the power condition before the first use.

-

Without sub-base

M5

Lamp and Surge Voltage Suppressor

USING TYPE ●

-

Standard type

V

For a vacuum

With sub-base

SET

RESET

RED LAMP

GREEN LAMP

COIL RATED VOLTAGE ● 4

DC 24V

CONNECTOR ● E-type Plug Connector

E-type Plug Connector

(with 300 mm lead wire)

(no connector)

E

A

EN

COMMON

■ HOW TO ORDER CONNECTOR CA3 - V4 - 6 ● LEAD WIRE LENGTH

DC 24V

-

300 mm

6

600 mm

10

1,000 mm

WHITE RED BLACK

A C B

COIL RATED VOLTAGE ● V4

SET

SET

R (3) P (1)

A(2) RESET

Air blow

12

R (3) P (1)

A (2) RESET

Operation of the singleacting cylinder

SET

R (3) P (1)

COM. (+/-) SET

Lead Wire Length

EX) USE OF THE VALVE LV290-4E

RESET

Air operated valve

A (2) RESET

For controlling the air pilot valve

LV290V-4E

3(R) 1(P)

For a vacuum

2(A)

B


■ PARTS DRAWING

LV290 Series

RESET 2

3

4

SET 6

7

8

1

5

9 R

10

No.

Part's name

A

Material

BODY

PLASTIC

'SET' COIL

-

'RESET' COIL

-

FIXED CORE

SUS

MOVING CORE

SUS, PLASTIC

POPPET

11

P

NBR

MAGNET

-

GUIDE RING

PLASTIC

GASKET

NBR

SCREW

-

BASE

Zn

■ SPECIFICATIONS Model

Items

LV290

LV290V

Valve structure

Direct-acting Poppet type

Fluid

Air or insert gas 2

Pressure range Effective area

-100 kPa~0.2 MPa (-0.1~2.0 kgf/cm2)

0~0.7 MPa (0~7.1 kgf/cm ) 2

P(1)

A(2)

0.2 mm (Cv 0.011)

0.2 mm2 (Cv 0.011)

A(2)

R(3)

0.2 mm2 (Cv 0.011)

0.2 mm2 (Cv 0.011)

Ambient and fluid temperature

Max. 50°C 1)

Response time

5 ms or less

Lubrication

Not required

Shock / Vibration resistance

150/30 (m/s2)

Protection structure

Dust proof

Coil rated voltage

DC 24V

Allowable voltage

±10% of rated voltage

Coil insulation

Class B or equivalent (130°C)

Power consumption(Current)

SET: 0.85W / RESET: 0.7W

Lamp

SET: RED / RESET: GREEN

1) There should be a measure to prevent freezing and dew condensation at a low temperature below 5°C.

13


■ DIMENSIONS

LV290 Series

LV290-4E-M5 E-type Plug Connector

12.4 14.8

9.9

7.5

R 2-Ø2.7

3.7

~300 =

12 18

A C B

5

14

3-M5 34.2

3

P 1

5

R

5

7

5

A 2

11

29.5

39.5

B C A

5


UV280 Series

Universal Type / 3-port Direct Poppet

■ HOW TO ORDER UV 280 - 4

Q

- M5

UNIVERSAL TYPE VALVE (UV280) ●

● PORT SIZE

UV280 is designed to use normal close (N.C.) and normal open (N.O.) freely just by selecting the port for supply. So you can select any port for the supply or exhaust as 6 methods below. 1. 3-port Valve

(Normally Open Type)

A(2)

A(2)

R(3)

P(1)

3. 2-port Valve

Without sub-base With sub-base

● LAMP AND SURGE VOLTAGE SUPPRESSOR

2. 3-port Valve

(Normally Closed Type)

R(3)

M5

P(1)

-

Standard type (Non-polar)

Z

Polar lamp - with Diode (DC)

S

Non-polar lamp - with surge voltage suppressor

■ DC Circuit Diagram

4. 2-port Valve

(Normally Closed Type)

(-)(+)

(Normally Open Type)

A(2)

(Standard type)

A(2)

DC

SOL.

DC

SOL.

DC

SOL.

(+)(-) R(3)

P(1)

5. Selector Valve

R(3)

P(1)

+

(Z type)

6. Divider Valve

A(2)

R(3)

(-)(+)

A (2)

(S type)

P(1)

R (3) P (1)

(+)(-)

R

COIL RATED VOLTAGE ● 3

DC 12V

4

DC 24V

6

DC 6V

9

Special orders

R AC110V R

LED

D

LED

D

SOL.

R R AC220V R

CONNECTOR ● Q-type Plug Connector

Q-type Plug Connector

(with 300 mm lead wire)

(no connector)

Q

QN

SOL.

R

■ HOW TO ORDER CONNECTOR CA2 - V4 - 6

E

E-type Plug Connector

E-type Plug Connector

(with 300 mm lead wire)

(no connector)

EN

COIL RATED VOLTAGE ● V4

DC voltage

● LEAD WIRE LENGTH -

300 mm

6

600 mm

10

1,000 mm

15

1,500 mm

20

2,000 mm

25

2,500 mm

30

3,000 mm

50

5,000 mm

15


■ PARTS DRAWING

UV280 Series

NORMAL 2

3

4

ENERGIZED 5

1

6 R

A

P

7

No.

Part's name BODY

8

COIL ASS’Y

-

FIXED CORE

SUS

MOVING CORE

■ SPECIFICATIONS Model

Items Valve structure

UV280 Direct-acting Poppet type

Fluid

Air or insert gas

Pressure range

-100 kPa~0.7 MPa (-0.1~7.1 kgf/cm2)

Effective area

P(1)

A(2)

1.2 mm2 (Cv 0.066)

P(1)

A(2)

1.2 mm2 (Cv 0.066)

Ambient and fluid temperature

1)

Max. 50°C

Response time

6 ms or less

Lubrications

Not required

Shock /Vibration resistance

150/30 (m/s2)

Protection structure

Dust proof

Coil rated voltage

DC 6V, 12V, 24V

Allowable voltage

±10% of rated voltage

Coil insulation

Class B or equivalent (130°C)

Power consumption

DC: 1W

1) There should be a measure to prevent freezing and dew condensation at a low temperature below 5°C.

16

Material PLASTIC

SUS, PLASTIC

SPOOL

AL, NBR

GASKET

NBR

SCREW

-

BASE

Zn


■ DIMENSIONS

UV280 Series

UV280-4E-M5

7.5

12.4 14.8

9.9

P-type Plug Connector

R 2-Ø2.7

3.7

~300 =

12 18

3-M5

5

5

P 1

5

3

R

7

5

A 2

11

29.5

39.5

MANUAL BUTTON

5

29.2

UV280-4Q-M5 Q-type Plug Connector

7.5

R 2-Ø2.7

12 18

3.7

~300 =

35.2

9.9

5

3-M5

29.2

P 1

5

3

5

R

7

5

A 2

11

29.5

MANUAL BUTTON

5

17


Manifold Block

3-port Solenoid Valve / Direct Poppet

MV290 Series

■ HOW TO ORDER MV290 - 05 - C4 - V STATIONS ● 02

● PIPING

2 Stations

20

-

Horizontal type

V

Vertical type

20 Stations

● PORT SIZE A(2)

■ MANIFOLD SPECIFICATIONS

One-touch fitting for Ø4 M5 thread

■ HOW TO ORDER MANIFOLD ASSEMBLY

MODEL

MV290

Port P(1) / R(3) style

Common SUP / Common EXH

Valve stations

2~20 Stations

Port Size

C4 M5

P(1), R(3)

M5×0.8

A(2)

C4, M5×0.8

MV290-05-C4-V: Horizontal 5-station manifold V290-4E: Valve BP-V290: Blank plate

(Example)

(1 Set) (4 Set) (1 Set)

V290-4E (4 Set)

Horizontal type (MV290-05-C4)

MV290-05-C4-V (1 Set)

BP-V290 (1 Set) LEF T

P-type Plug Connector

E-type Plug Connector

Lead wire type

Sta tion 1

Q-type Plug Connector

·2 ·

3 ·4

RIG HT

·5 ·

··

Vertical type (MV290-05-C4-V) Stations

Model

V290-

P

V290-

E

V290-

Q

V290-

L

1

2

3

4

5

6

·

·

·

LV290-4E

P-type Plug Connector

E-type Plug Connector

Lead wire type

UV280-

Q

UV280-

E

BP-V290 Manifold Block

MV290-05-C4-V

■ MANIFOLD ASSEMBLY FORM 

Stations

Model

V290-

P

V290-

E

V290-

Q

V290-

L

LV290-4E UV280-

Q

UV280-

E

BP-V290 Manifold Block

18

02

LEFT

03

04

05

RIGHT 06

07

08

09

10

11

12

13

14

15

16

17

18

19

20

·

·

 ·


■ DIMENSIONS

MV290 Series

MV290 - 05 - C4 P-type Plug Connector

~ 300 =

31.5 16.3 13 8.7

11.5 11.5

5 9.9 25

Q-type Plug Connector 41.6

32.5

4-M5 (P, R-PORT)

n

n-C4 (A-PORT)

7.25 2

7.25 2

7.25 2

5 9.9 25

5 9.9 25

38

38

Lead wire type (L)

4-M5 (P, R-PORT)

31.5

4-M5 (P, R-PORT)

~ 300 =

n-C4 (A-PORT)

~ 300 =

~ 300 =

43

41.5

7.25 2

P=10

L1 (10n+13) L2 (10n+7)

4-M5 (P, R-PORT)

32.5

9.9

31.6 25

3

2-Ø3.5

E-type Plug Connector

n-C4 (A-PORT)

5 9.9 25

38

n-C4 (A-PORT) 38

02

03

04

05

06

07

08

09

10

11

12

13

14

15

16

17

18

19

20

∙∙∙

L1

33

43

53

63

73

83

93

103

113

123

133

143

153

163

173

183

193

203

213

∙∙∙

L2

27

37

47

57

67

77

87

97

107

117

127

137

147

157

167

177

187

197

207

∙∙∙

L

MV290 - 05 - C4 -V E-type Plug Connector 36.7 25 15.1

~ 300 =

31.5 16.3 13

48.2

5

7.25 2

n-C4 (A-PORT)

9.9 10.1 36.7

4-M5 (P, R-PORT)

11.5

P=10 L2 (10n+7) L1 (10n+13)

11.5

3

2-Ø3.5

P-type Plug Connector

~300 =

5

5

9.9 10.1 36.7

4-M5 (P, R-PORT)

n-C4 (A-PORT)

7.25 2

7.25 2

n-C4 (A-PORT)

32.5

41.5

~ 300 =

Lead wire type (L)

9.9 10.1 36.7

4-M5 (P, R-PORT)

19


V200 Series

2-port Solenoid Valve / Direct Poppet

■ HOW TO ORDER L V200 LATCHING TYPE ●

- 4

P

- M5

USING TYPE ●

● PORT SIZE

-

Static pressure

SUB BASE

V

Vacuum

(without fitting)

M5

COIL RATED VOLTAGE ● 1

AC 110V

2

AC 220V

3

DC 12V

4

DC 24V

6

DC 6V

9

Special orders

SUB BASE (with one-touch fitting for Ø4, Ø6 )

C4 / C6

CONNECTOR ● P-type Plug Connector

P-type Plug Connector

(with 300 mm lead wire)

(no connector)

P

● LAMP AND SURGE VOLTAGE SUPPRESSOR

PN

E-type Plug Connector

E-type Plug Connector

(with 300 mm lead wire)

(no connector)

E

-

Standard type (Non-polar)

Z

Polar lamp - with Diode (DC)

S

Non-polar lamp - with surge voltage suppressor (DC)

■ DC Circuit Diagram (-)(+)

(Standard type)

EN

DC

SOL.

DC

SOL.

DC

SOL.

(+)(-) +

(Z type)

Latching type (LV200V) is available only for E-type (DC voltage). (-)(+)

■ HOW TO ORDER CONNECTOR CA2 - V4

6

(S type) (+)(-)

● LEAD WIRE LENGTH 6 10 15 20 25 30 50

Connector assembly

COIL RATED VOLTAGE ● V1

AC 110V

V2

AC 220V

V4

DC voltage

■ AC Circuit Diagram

300 mm 600 mm 1,000 mm 1,500 mm 2,000 mm 2,500 mm 3,000 mm 5,000 mm

R R AC110V R

V200V- P

P

A

1(P)

2(A)

P

Valve for the air blow

20

Valve for a vacuum

LV200V- RESET

A A

Valve for the vacuum ejector

D

R

EX) USE OF THE VALVE

A

LED

SOL.

AC220V R

P

D

R

R

V200-

LED

Valve for a vacuum

1(P) SET

2(A)

Valve for a vacuum

SOL.


■ PARTS DRAWING

V200 Series

NORMAL 2

3

ENERGIZED

4

5

1

6 INLET

INLET

OUTLET

7

No.

Part's name

Material

BODY

8

PLASTIC

COIL ASS’Y

-

FIXED CORE

SUS

MOVING CORE

SUS, PLASTIC

POPPET

NBR

GASKET

NBR

SCREW

-

BASE

Zn

■ SPECIFICATIONS Model

Items

Vacuum 1)

Static Pressure V200

V200V

Valve structure Fluid

Air or insert gas 2

Pressure range Effective area

LV200V

Direct-acting Poppet type

P(1)

0~0.7 MPa (0~7.1 kgf/cm ) A(2)

-100 kPa~0.2 MPa (0~2.0 kgf/cm2) 1.5 mm (Cv 0.083)

Ambient and fluid temperature

Max. 50°C 2)

Response time

6 ms or less

Lubrication

Not required

Manual operation

Push type

Shock / Vibration resistance

150/30 (m/s2)

Protection structure

Dust proof

Coil rated voltage

DC 6V, 12V, 24V / AC 110V, 220V

Allowable voltage

±10% of rated voltage

Coil insulation

Class B or equivalent (130°C)

Power consumption

-100 kPa~0.1 MPa (-0.1~1.0 kgf/cm2)

2

DC: 1W / AC 110V: 1.0VA / AC 220V: 2.0VA

DC 24V

SET: 0.85W / RESET: 0.7W

1) When you use vacuum valves, the vacuum should be connected to the OULET side. 2) There should be a measure to prevent freezing and dew condensation at a low temperature below 5°C.

21


■ DIMENSIONS V200

V200 Series

-4P

-M5

P-type Plug Connector MANUAL BUTTON

9.9

7.5

40.5

29.5

~300 =

1

A

2

-4E

5

5

2-M5

5

V200

OUTLET

INLET

7

11

P

29.2

18.0

5

-M5

E-type Plug Connector 7.5

29.5

39.5 (E TYPE)

~300 =

9.9

MANUAL BUTTON

1

OUTLET

A

2

2-M5

5

5

5

22

INLET

7

11

P

18.0 29.2 34.2 (LV200V, V200 AC)

5


Manifold Block

2-port Solenoid Valve / Direct Poppet

MV200 Series

■ HOW TO ORDER MV200 - 04 - C6 - V ● PORT SIZE

STATIONS ● 02

2 Stations

20

● PIPING

20 Stations

M5

M5 thread

C4

One-touch fitting for Ø4

C6

One-touch fitting for Ø6

-

Horizontal type

V

Vertical type

■ MANIFOLD SPECIFICATIONS MODEL

MV200 Series

Port P(1)

Common SUP / Common EXH

Valve stations

2-20 stations P-port: Rc( PT) 1/8

Port size

A-port: M5×0.8

A(2) Port

C4, C6, M5

Horizontal type

Vertical type

■ DIMENSIONS ~300 =

47.9 (P TYPE) 30 12.5

40.5 (E TYPE) 6 3

40.5 (E TYPE)

2-Ø3.5

47.9 (P TYPE) 30 12.5

11.5

11.5

PITCH=10 L2 (10n+7) L1 (10n+13) n-C4, C6, M5 (A-PORT)

L2 (10n+7) L1 (10n+13)

PITCH=10 n-C4, C6, M5 (A-PORT)

A

A

3

~300 =

MV200- 08 - C4 2-Ø3.5

MV200- 08 - C4 -V

36.4

30.5 6

6

30.5

36.4

P-PORT Rc (PT) 1/8 n

P-PORT Rc (PT) 1/8

02

03

04

05

06

07

08

09

10

11

12

13

14

15

16

17

18

19

20

∙∙∙

L1

33

43

53

63

73

83

93

103

113

123

133

143

153

163

173

183

193

203

213

∙∙∙

L2

27

37

47

57

67

77

87

97

107

117

127

137

147

157

167

177

187

197

207

∙∙∙

L

23


V190 Series

3-port Solenoid Valve / Direct Poppet

■ HOW TO ORDER V 1 9 0

- 4

P

- M5

A(2)

● ACTUATION R (3) P (1) Normally closed type

9

● PORT SIZE -

A(2)

M5

Without sub-base With sub-base

R (3) P (1)

POWER CONSUMPTION ●

● LAMP AND SURGE VOLTAGE SUPPRESSOR

Power Consumption

Effective Area

-

Standard type (Non-polar)

-

0.7W (standard type)

0.2 mm2

Z

Polar lamp - with Diode (DC)

Y

0.35W (low-watt type)

0.15 mm2

S

Non-polar lamp - with surge voltage suppressor (DC)

■ DC Circuit Diagram

COIL RATED VOLTAGE ● 3

DC 12V

4

DC 24V

6

DC 6V

9

Special orders

(-)(+)

(Standard type)

SOL.

DC

SOL.

DC

SOL.

(+)(-) +

(Z type)

CONNECTOR ● P-type Plug Connector

P-type Plug Connector

(with 300 mm lead wire)

(no connector)

P

DC

(-)(+)

(S type) (+)(-)

PN R

R

E

E-type Plug Connector

E-type Plug Connector

(with 300 mm lead wire)

(no connector)

AC110V R

LED

D

LED

D

SOL.

R

EN

R AC220V R

SOL.

R

■ HOW TO ORDER CONNECTOR CA2 - V4 - 6 COIL RATED VOLTAGE ● V4

24

DC voltage

● LEAD WIRE LENGTH -

300 mm

6

600 mm

10

1,000 mm

15

1,500 mm

20

2,000 mm

25

2,500 mm

30

3,000 mm

50

5,000 mm


■ PARTS DRAWING

V190 Series

V190 (Normally closed) NORMAL 3

2

ENERGIZED

4 5

1

6

R

A

P

7

No.

Part's name

Material

BODY

8

PLASTIC

COIL ASS’Y

-

FIXED CORE

SUS

MOVING CORE

SUS

POPPET

NBR

GASKET

NBR

SCREW

-

BASE

AL

■ SPECIFICATIONS Model

Items

V190 (Standard type)

Valve structure

V190Y (Low-watt type) Direct-acting poppet type

Fluid

Air or insert gas

Pressure range

0~0.7 MPa (0~7.1 kgf/cm2)

Effective area

P(1) A(2)

A(2)

0.2 mm2

0.15 mm2

R(3)

2

0.15 mm2

0.2 mm

Ambient and fluid temperature

Max. 50°C

Response time

5 ms or less

Lubrication

Not required

Manual operation

Push Type

Shock / Vibration resistance

150/30 (m/s2)

Protection structure

Dust proof

Coil rated voltage

DC 6V, 12V, 24V

Allowable voltage

±10% of rated voltage

Coil insulation

Class B or equivalent(130°C)

Power consumption (Current)

0.7W

0.35W

25


■ DIMENSIONS

V190 Series

V190 - 4 P-M5 P-type Plug Connector MANUAL BUTTON

10.0 12.5

2.0

2-Ø2.7

~ 300 =

11 16

2.5

7.4

3.8

7.2 29.2

3-M5

8.8

4.5

4.5

4.5

11.5

27.7

40.5

3.8

V190 - 4 E-M5 E-type Plug Connector

MANUAL BUTTON

10.0 12.5

7.4

2.0

11 16

2.5

3.8

26

3-M5

7.2 29.2

8.8

4.5

4.5

4.5

11.5

27.7 37.4

~ 300 =

2-Ø2.7

3.8


Manifold Block

3-port Solenoid Valve / Direct Poppet

MV190 Series

■ HOW TO ORDER MV190 - 05 - C3 ● PORT SIZE

STATIONS ● 02

C3

One-touch fitting for Ø3

M5

M5 thread

2 Stations

20

20 Stations

■ MANIFOLD SPECIFICATIONS MODEL

MV190

P(1)·R(3) style

Common SUP / Common EXH

Valve stations

2~20 Stations

Port Size

P(1), R(3)

M5×0.8

A(2)

C3, M5×0.8

P-type Plug Connector

■ DIMENSIONS

E-type Plug Connector

MV190 - 05 - C3 32.1 25.5 10.5

R

A

P

10.25

P=7.5

L1 (7.5n+13) L2 (7.5n+7)

P

R

3.0

2-Ø3.5

10.25

28.7 15.8 12.5 8.0

E-type Plug Connector ~300 =

P-type Plug Connector ~300 =

4-M5 (P, R-PORT)

5.25

5.25

28.7

4-M5 (P, R-PORT)

n-C3 (A-PORT)

10.5 25.5 38.2

5.0

n

38.4

43.3

n-C3 (A-PORT)

10.5 25.5 38.2

5.0

02

03

04

05

06

07

08

09

10

11

12

13

14

15

16

17

18

19

20

∙∙∙

L1

22

29.5

37

44.5

52

59.5

67

74.5

82

89.5

97

104.5

112

119.5

127

134.5

142

149.5

157

∙∙∙

L2

28

35.5

43

50.5

58

65.5

73

80.5

88

95.5

103

110.5

118

125.5

133

140.5

148

155.5

163

∙∙∙

L

27


KV Series

SV Series

3 .5 Port Solenoid Valve / Pilot Type

3 .5 Port Solenoid Valve / Pilot Type

● Compact size with large flow capacity

● Wide range of port sizes and body sizes (M5~Rc(PT)3/4)

● Exceedingly long life (More than 50 million cycles)

● Superior flow features and high reliability

● Fitting attached valve and manifold block

● Low power consumption and simple maintenance

● D-SUB Connector and DIN RAIL

● Various kinds of wire distributing type

● Easy manual operation

● Air operated valves

MC/SC/FC Series

B20, 30, 40 Series

Air Cylinder (Mini, Compact & Standard)

Air Clean Unit

● The best use of space

● Newly-designed space-saving air clean unit

● Easy to attach auto-switches

● Rovolving one-touch type drain cock

● Lowered maintenance cost

● Easy to assemble bracket spacer

● Enhanced Kinetic Energy

● Slim and square-shaped pressure gauge (option)

● Improved mounting accuracy

● Convenient adjustment of oil dripping quantities with scale

HEADQUARTERS 3Na-210, Sihwa Industrial Complex, Jeongwang-dong, Siheung-si, Gyeonggi-do, Korea TEL +82-31-499-5500 FAX +82-31-499-5505 http://www.sym21.com

SALES DIVISION 101-505, SK VENTIUM, Dangjeong-dong, Gunpo-si, Gyeonggi-do, Korea TEL +82-31-436-0001 FAX +82-31-436-0099

The contents of this catalogue are subject to be modified without notice for further product improvement. ⓒ 2011. 12. SHINYEONG MECHATRONICS CO., LTD. All rights reserved.

ISO 9001 인증업체


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.