Switcher Soft Reset
If required, the switcher can be reset to return it to a user-defined default setting, or the factory default state. A reset can be performed for the entire switcher, or individual components, such as keys.
Soft Reset
Advertisement
The software reset returns the switcher to the default state. Black is selected on all buses, all keys are cut off-air, and the transition rate is set back to default. This is useful if you need to return the switcher to a known state.
To Reset the Switcher Software
1. Press and hold MENU. 2. Press Reset All (RESET on the C10/C1).
Custom Reset Settings
You can customize many of the default switcher parameters and save them as a user-defined reset settings. These custom reset settings can then be recalled when you want to return the switcher to a previous state.
To Save a Custom Reset Setting
You can customize many of the default switcher parameters and save them as a user-defined custom reset.
Tip: Custom reset settings can also be set from the Memory > RState tabs on the Live Assist node in DashBoard.
1. Press MENU > RESET > NEXT. 2. Use the Attrib knob to select Media. 3. Use the Media knob to select Media1. 4. Use the Value knob to select whether the
Media-Store channel is reset with a switcher reset or not. • NoRst — the Media-Store channel is not reset • Reset — the Media-Store channel is reset with a switcher reset
5. Repeat this for the remaining Media-Store channels. 6. Use the Attrib knob to select Aux. 7. Use the Aux knob to select Aux 1. 8. Use the Value knob to select whether the Aux bus is reset with a switcher reset or not. • NoRst — the Aux bus is not reset • Reset — the Aux bus is reset with a switcher reset
9. Repeat this for the remaining Aux buses. 10. Press NEXT > NEXT > NEXT. 11. Press RState Save and Confrm.
To Load a Custom Reset Setting
Tip: Custom reset settings can also be set from the Memory > RState tabs on the Live Assist node in DashBoard.
1. Press MENU > RESET. 2. Press RState Load.
You can also press and hold MENU and press
Reset All (RESET on the C10/C1).
Factory Default Settings
You can restore the switcher to the factory default state. All installation and personality settings are reset.
To Factory Reset the Switcher
1. Press MENU > RESET > NEXT > NEXT. 2. Press the Factry Reset knob. 3. Press the Confrm knob to load the factory default settings.
Resetting Individual Components
You can reset only the component that you want, instead of the entire switcher. Individual MEs, keys, aux buses, dissolves, wipes, and menu items can be reset.
Table 7: Resetting Individual Components
To Reset Buttons to Press Result
Wipes
Dissolves
Keys
MEs WIPE and RESET all wipe parameters, including position, pattern, and border, are reset
DISS and RESET
KEY X SEL and
RESET
ME X and RESET (C10/C1)
ME X STORE and ME
X RECALL
(C1-A/C1M/C2/C2M/C2S/C2X) all dissolve parameters are reset
key parameters for key X including clip, gain, and mask, are reset, but not key type, or chroma key color selection (each keyer is reset individually) (X is the number of the key)
ME X parameters, including source selections, are reset (each ME is reset individually) (# is the number of the ME)
To Reset Buttons to Press Result
Aux Buses STORE and RECALL for the selected MEs (C3S/C3X)
AUX X and RESET
Menu Items double-press the knob for the value you want to reset Aux bus X parameters, including source selections, are reset (each Aux is reset individually) (X is the number of the aux bus)