Mobility Custom Product Catalog Supplement

Page 1

hearing solutions

custom wireless p r o d u c t C ATA L O G s u p p l e m e n t | j a n 2 0 1 2

TM


Mobility Custom Feature Chart

Mobility Custom Feature Summary

,

SurfLink™ Accessories

Mobility ITE

Mobility HS

Mobility ITC

Patients come to you seeking a hearing solution that fits them perfectly. Offer them the best with Mobility wireless hearing aids. Already a proven favorite with clinicians and patients, we’ve enhanced our product line with new custom styles — including our fully functional CIC — as well as an array of innovative features designed to help you bring better hearing to more patients than ever.

Mobility CIC

1 3 5 7 8 9 10


Sound Imaging

Binaural Spatial Mapping

VIBRANT

ACTIVE

SOCIAL

Optimal high-resolution sound imaging with frequency shaping in all 16 channels and 16 bands

High-resolution sound imaging with frequency shaping in 12 channels and 12 bands

Frequency shaping in 8 channels and 8 bands

Premium Ear-to-Ear Processing

Advanced Ear-to-Ear Processing

Premium 16-channel environmental adaptation with 5 levels of personalization

Advanced 12-channel environmental adaptation with 3 levels of personalization

Select 8-channel environmental adaptation with 2 levels of personalization

Maximum (20dB)

Moderate (8dB)

Light (6dB)

5

3

on/off

Machine Noise

W I R E L E S S

Wind Directionality Synchronized User Controls Binaural Telephone Mode Volume Memory SurfLink Accessory Compatibility SurfLink Programmer SurfLink Media SurfLink Remote SpeechTrax Boost Strategic Feedback Control

TM

feature chart

Adaptive Environmental Sequencing SpeechTrax2 Noise Reduction Strength Acoustic Landscapes Machine Noise Speech in Noise Wind Quiet Speech Noise Acoustic Landscape Adaptation Levels FrequencyTrax SoundPoint Self Learning Swap Fit 3D Speech Mapping

All MObility models include: Dynamic Directional Detection (not available on CIC) Automatic Telephone Solutions Live Real Ear Measurement Live Speech Mapping Advanced Memories (Music, TV, Relax, T-Coil, Binaural Processing Off) Indicators (Level-Dependent Speech, Level-Dependent Tone) T2 On Demand Programming 1

Self Check In-Situ Audiometry Auto Path Verify Comfort Data Logging 4 Memories 2


TM

feature summary

IRIS™ Technology leverages a unique ear-to-ear communication protocol. Binaural Spatial Mapping applies the combined speed and power of multiple dual-core platforms to achieve parallel processing benefits. This innovative protocol queries, analyzes, and maps the acoustic space surrounding the patient, applying the appropriate signal processing strategy for directionality and noise management. SpeechTrax2 nearly doubles the noise reduction capability of our leading noise reduction and speech preservation system while still maintaining speech. SpeechTrax2: • Instantly applies variable noise adaptation in all channels between each pause • Has been proven to reduce listening effort and cognitive fatigue when used in tandem with Dynamic Directional Detection* • Provides up to 20dB of noise reduction Unlike competing technologies that apply frequency compression broadly, our frequency lowering technology, FrequencyTrax, is designed to enhance real-time audibility by intelligently identifying high-frequency speech cues, then replicating them in lower frequencies. This allows Mobility to maintain important frequency relationships, retaining the sound quality that comes from harmonic distribution, while providing audibility for high-frequency speech cues for patients that may have previously been considered unaidable. Activated via SurfLink Remote, our SpeechTrax Boost feature allows patients to enable aggressive noise reduction while optimizing sound quality in extremely noisy situations. Thanks to Self Learning, Mobility gradually and automatically learns patient volume control preferences in each active memory, which helps reduce the number of manual volume control adjustments patients need to make. Mobility wouldn’t be a MicroTech product without our Strategic Feedback Control. This leading technology ensures wide fitting ranges and a fast response to more complex feedback. Our innovative Hear Clear™ with HydraShield®2 enables all Mobility custom wireless products to provide unprecedented resistance to wax and moisture.

With Synchronized User Adjustments patients can use a single hearing instrument to adjust volume or memory for the pair — eliminating the need to manually change two instruments. Binaural Telephone Mode places the phone-side hearing aid in Automatic Telephone Response or Telecoil mode while attenuating the off-side hearing aid. Dynamic Directional Detection in Mobility hearing aids is designed to better perform in highly complex environments with background noise (Not available on CIC). MicroTech was the first company to integrate real-ear measurement into a hearing aid. Live Real Ear Measurement provides a prescriptively appropriate fitting for every Mobility product. Combined with the power of Inspire® fitting software, it lets you see the hearing aid output in your patient’s ear in real-ear SPL. Voice Indicators alert your patients to the status of their hearing aid, low battery, memory and telephone modes in their choice of male or female voices in a wide variety of languages. Automatic Telephone Solutions (ATS) automatically detects telephone use and adjusts to the optimal acoustic frequency response for telephone listening. Bring the benefits of telehealth to your practice with our On Demand options. Each one is designed to elevate your interaction with patients and provide a better way for you to deliver care. Includes T2 On Demand, Audiology On Demand™ and innovative applications that work with the iPad®, iPhone® and iPod® Touch.

Color Guide Faceplate Colors

Shell Colors

Our Swap Fit fitting function allows you to transfer patient settings from their current MicroTech product to a new one — enabling more time for fine-tuning and counseling. Pink

Light Brown

Medium Brown

Chestnut

Dark Brown

Pink

Light Brown

Clear

Blue/Red

* Sarampalis, A., Kalluri, S., Edwards, B., Hafter, E. (2009, October). Objective measures of listening effort: Effects of background noise and noise reduction. Journal of Speech, Language, and Hearing Research, 52, 1230-1240.

3

4


accessories SurfLink Remotes

SurfLink Programmer Our SurfLink Programmer, combined with IRIS Technology and Inspire fitting software, gives you the ultimate speed and flexibility in direct-to-hearing aid wireless programming.

• D etects your patients’ Mobility devices in seconds

Basic

Intermediate

Advanced

With the optional SurfLink Remote, patients can control memory and volume adjustments, mute their hearing instruments, or go in and out of streaming mode if they desire.

• Connects via standard USB cable

• Features up to a 20-foot range

• R equires no additional hardware for the patient

• Frees patients to move around during counseling and demonstrations

• Is 4x faster than HiPro and nearly twice as fast as NOAHLink and nEARcom

SurfLink Media SurfLink Media provides patients with the first set-and-forget media streaming solution. Simply plug a TV, radio or MP3 player into SurfLink Media and rich, stereo sound is streamed directly to any Mobility hearing aids in range without pairing or body-worn relay devices. SurfLink Media:

• S treams stereo sound directly from media devices to the patient’s hearing aids without pairing or body-worn relay devices • U ses Intelligent Media Mobility to allow seamless room-to-room transitions between media devices

5

• Enables multiple people wearing Mobility hearing aids to connect to a single device • E liminates audio delay and lip-sync issues* commonly found with other wireless systems • H elps prevent patients and companions from fighting over the volume

*Latency is unnoticeable according to International Telecommunications Union standards.

6


ITE

HS

in-the-ear

half-shell Matrices: 115/50, 123/60 Maximum Output: Up to 30dB Reduction in 2dB Steps (range varies by channel) Compression Threshold: 24dB Range in 4dB Steps Compression Ratio: 1:1-3:1 (range varies by channel) Battery Size: 13

ITE 115/50

ITE 123/60

Matrices: 110/40, 115/50 Maximum Output: Up to 30dB Reduction in 2dB Steps (range varies by channel) Compression Threshold: 24dB Range in 4dB Steps Compression Ratio: 1:1-3:1 (range varies by channel) Battery Size: 312

HS 110/40

HS 115/50

0

0

10

10

20

20

ANSI/IEC 2cc Coupler

IEC OES Coupler

ANSI/IEC 2cc Coupler

IEC OES Coupler

ANSI/IEC 2cc Coupler

IEC OES Coupler

ANSI/IEC 2cc Coupler

IEC OES Coupler

Peak OSPL90 (dB SPL)

115

124

123

130

110

119

115

124

Peak OSPL90 (dB SPL)

HFA OSPL90 (dB SPL)

110

NA

116

NA

105

NA

109

NA

HFA OSPL90 (dB SPL)

Measurement

30 40

Measurement

30 40

50

50

60 70

60 70

80

80

110 120 1K

2K

4K

50

110

40

100

30

90

20

80

10

70 1000

FOG 50

NA

116

Peak Gain (dB)

50

58

60

68

40

49

50

58

HFA Full-On Gain (dB)

46

NA

53

NA

36

NA

46

NA

HFA Full-On Gain (dB)

RTF Full-On Gain (dB)

NA

54

NA

66

NA

43

NA

53

RTF Full-On Gain (dB)

Reference Test Gain (dB)

NA 1.0, 1.6, 2.5 33

1.6

NA

NA

1.0, 1.6, 2.5

41

39

1.6

100 - 7000 100 - 7200 100 - 6500 100 - 6800 NA

NA

1.0, 1.6, 2.5

53

28

1.6

NA

1.6

RTF OSPL90 (dB SPL)

NA

HFA Frequencies (kHz)

36

32

41

Reference Test Gain (dB)

110

40

100

30

90

20

80

10000

OSPL90 (dBSPL)

50

OSPL90 (green) and Full-On Gain (blue) curves for the Mobility ITE at 123/60.

OSPL90

Harmonic Distortion

500 Hz (%)

<3

<3

<3

<3

<3

<3

<3

<3

500 Hz (%)

800 Hz (%)

<3

<3

<3

<3

<3

<3

<3

<3

800 Hz (%)

1600 Hz (%)

<3

<3

<3

<3

<3

<3

<3

<3

1600 Hz (%)

Release Time 2.0s (ms)

20

20

20

20

20

20

5-150

5-250

5-150

5-250

5-150

5-250

5-150

5-250

5-150

5-250

5-150

5-250

5-150

5-250

5-150

5-250

Induction Coil Sensitivity

2K

4K

8K

FOG 50

60

120

50

110

40

100

30

90

20

80

10

70

Wi Series ITC/HS 50 – 2cc OSPL90

Release Time 0.1s (ms) Release Time 2.0s (ms)

HFA SPLITS (ANSI) (dB SPL)

95

NA

101

NA

89

NA

94

NA

HFA SPLITS (ANSI) (dB SPL)

MASL (IEC) (dB SPL)

NA

83

NA

95

NA

71

NA

82

MASL (IEC) (dB SPL)

ANSI/IEC Battery Current (mA)

1.22

1.22

1.22

1.22

1.22

1.22

1.22

1.22

ANSI/IEC Battery Current (mA)

Idle Current (mA)

1.14

1.15

1.13

1.13

1.15

1.15

1.15

1.15

Idle Current (mA)

FOG 50

60

120

50

110

40

100

30

90

20

80

10 100

70

10000

OSPL90 (green) and Full-On Gain (blue) curves for the Mobility HS at 110/40.

Attack Time (ms)

Induction Coil Sensitivity

1000

Frequency (Hz)

Attack and Release Time (ANSI/IEC) – Test Mode 20

1K

Wi Series ITC/HS 40 – 2cc

Reference Test Frequency (kHz)

NA

20

500

Mobility HS fitting range.

Frequency Range (Hz)

Frequency (Hz)

70 1000

10000

Frequency (Hz)

Estimated Battery Life for 16-Hour Day 13 Zinc Air (days)

7

120

Peak Gain (dB)

1.0, 1.6, 2.5

Harmonic Distortion

Release Time 0.1s (ms)

120

1000

HFA Frequencies (kHz)

Attack Time (ms) 130

60

FOG 50 (dB)

111

Attack and Release Time (ANSI/IEC) – Test Mode

X Series ITE 60 – 2cc

100

NA

100

OSPL90 (green) and Full-On Gain (blue) curves for the Mobility ITE at 115/50.

10

128

10000

Frequency (Hz)

OSPL90

NA

Reference Test Frequency (kHz) 120

OSPL90 (dBSPL)

FOG 50 (dB)

FOG 50

60

70

116

Frequency Range (Hz) 100 - 6800 100 - 7000 100 - 5000 100 - 5100

Wi Series ITE 50 – 2cc

100

NA

250

Mobility ITE fitting range.

OSPL90

RTF OSPL90 (dB SPL) 8K

FOG 50 (dB)

500

110

FOG 50 (dB)

250

90 100

Estimated Battery Life for 16-Hour Day 12-16

12-16

12-16

12-16

NA

NA

NA

NA

13 Zinc Air (days)

312 Zinc Air (days)

NA

NA

NA

NA

8-9

8-9

8-9

8-9

312 Zinc Air (days)

10 Zinc Air (days)

NA

NA

NA

NA

NA

NA

NA

NA

10 Zinc Air (days)

OSPL90 (dBSPL)

100

OSPL90 (green) and Full-On Gain (blue) curves for the Mobility HS at 115/50.

8

OSPL90 (dBSPL)

90


ITC

CIC

in-the-canal

completely-in-canal Matrices: 110/40, 115/50 Maximum Output: Up to 30dB Reduction in 2dB Steps (range varies by channel) Compression Threshold: 24dB Range in 4dB Steps Compression Ratio: 1:1-3:1 (range varies by channel) Battery Size: 312

ITC 110/40

ITC 115/50

Matrices: 110/40, 115/50 Maximum Output: Up to 30dB Reduction in 2dB Steps (range varies by channel) Compression Threshold: 24dB Range in 4dB Steps Compression Ratio: 1:1-3:1 (range varies by channel) Battery Size: 10

CIC 110/40

CIC 115/50

0

0

10

10

20

20

ANSI/IEC 2cc Coupler

IEC OES Coupler

ANSI/IEC 2cc Coupler

IEC OES Coupler

ANSI/IEC 2cc Coupler

IEC OES Coupler

ANSI/IEC 2cc Coupler

IEC OES Coupler

Peak OSPL90 (dB SPL)

110

119

115

124

110

119

115

124

Peak OSPL90 (dB SPL)

HFA OSPL90 (dB SPL)

105

NA

109

NA

104

NA

110

NA

HFA OSPL90 (dB SPL)

Measurement

30 40

Measurement

30 40

50

50

60 70

60 70

80

80

110 120 1K

2K

4K

50

110

40

100

30

90

20

80

10

70 1000

116

NA

110

NA

115

Peak Gain (dB)

40

49

50

58

40

49

50

58

HFA Full-On Gain (dB)

36

NA

46

NA

35

NA

46

NA

HFA Full-On Gain (dB)

RTF Full-On Gain (dB)

NA

43

NA

53

NA

43

NA

54

RTF Full-On Gain (dB)

120

HFA Frequencies (kHz) Reference Test Gain (dB)

FOG 50

28

NA

NA

1.0, 1.6, 2.5

36

32

1.6

NA

NA

1.0, 1.6, 2.5

41

28

1.6

NA

1.6

NA

NA

HFA Frequencies (kHz)

35

32

40

Reference Test Gain (dB)

OSPL90

Harmonic Distortion <3

<3

<3

<3

<3

<3

<3

<3

500 Hz (%)

800 Hz (%)

<3

<3

<3

<3

<3

<3

<3

<3

800 Hz (%)

1600 Hz (%)

<3

<3

<3

<3

<3

<3

<3

<3

1600 Hz (%)

110

40

100

30

90

20

80

10 100

70 10000

Release Time 2.0s (ms) OSPL90 (dBSPL)

50

20

20

20

20

20

20

5-150

5-250

5-150

5-250

5-150

5-250

5-150

5-250

5-150

5-250

5-150

5-250

5-150

5-250

5-150

5-250

Induction Coil Sensitivity

FOG 50 120

110

40

100

30

90

20

80

10

70

NA

94

NA

NA

NA

NA

NA

HFA SPLITS (ANSI) (dB SPL)

MASL (IEC) (dB SPL)

NA

71

NA

82

NA

NA

NA

NA

MASL (IEC) (dB SPL)

ANSI/IEC Battery Current (mA)

1.22

1.22

1.22

1.22

1.17

1.17

1.17

1.17

ANSI/IEC Battery Current (mA)

Idle Current (mA)

1.15

1.15

1.15

1.15

1.12

1.12

1.13

1.13

Idle Current (mA) Estimated Battery Life for 16-Hour Day

NA

NA

NA

NA

NA

NA

NA

NA

10000

OSPL90 (green) and Full-On Gain (blue) curves for the Mobility CIC at 110/40. Wi Series CIC 50 – 2cc OSPL90

Release Time 2.0s (ms)

89

1000

Frequency (Hz)

Release Time 0.1s (ms)

HFA SPLITS (ANSI) (dB SPL)

13 Zinc Air (days)

8K

50

Attack Time (ms)

Induction Coil Sensitivity

Estimated Battery Life for 16-Hour Day

4K

60

Attack and Release Time (ANSI/IEC) – Test Mode 20

2K

Wi Series CIC 40 – 2cc

Reference Test Frequency (kHz)

1.0, 1.6, 2.5

20

1K

Mobility CIC fitting range.

Frequency Range (Hz)

500 Hz (%)

Release Time 0.1s (ms) 120

OSPL90 (green) and Full-On Gain (blue) curves for the Mobility ITC at 115/50.

1.0, 1.6, 2.5

1.6

Harmonic Distortion

Attack Time (ms)

60

Frequency (Hz)

NA

100 - 7500 100 - 7600 100 - 7500 100 - 7600

Attack and Release Time (ANSI/IEC) – Test Mode

Wi Series ITC/HS 50 – 2cc

1000

100 - 7000 100 - 7200 100 - 6500 100 - 6800

500

Peak Gain (dB)

100

OSPL90 (green) and Full-On Gain (blue) curves for the Mobility ITC at 110/40.

9

RTF OSPL90 (dB SPL)

10000

Frequency (Hz)

FOG 50 (dB)

NA

Reference Test Frequency (kHz) 120

OSPL90 (dBSPL)

FOG 50 (dB)

FOG 50

60

OSPL90

111

Frequency Range (Hz)

Wi Series ITC/HS 40 – 2cc

100

NA

250

Mobility ITC fitting range.

OSPL90

RTF OSPL90 (dB SPL) 8K

FOG 50 (dB)

500

110

FOG 50 (dB)

250

90 100

FOG 50

60

120

50

110

40

100

30

90

20

80

10 100

70 1000

10000

Frequency (Hz)

OSPL90 (green) and Full-On Gain (blue) curves for the Mobility CIC at 115/50.

13 Zinc Air (days)

312 Zinc Air (days)

8-9

8-9

8-9

8-9

NA

NA

NA

NA

312 Zinc Air (days)

10 Zinc Air (days)

NA

NA

NA

NA

4-6

4-6

4-6

4-6

10 Zinc Air (days)

OSPL90 (dBSPL)

100

10

OSPL90 (dBSPL)

90


TM


6425 Flying Cloud Drive Eden Prairie, MN 55344

800.745.4327 microtechhearingpro.com

Š 2011 MicroTech Hearing Technologies All Rights Reserved

85101-004 12/11 BKLT0283-00-EE-MT


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.